6.4E Transmit signal quality for V2X operation in FR1
38.521-33GPPNRPart 3: Range 1 and Range 2 Interworking operation with other radiosRadio transmission and receptionRelease 17TSUser Equipment (UE) conformance specification
6.4E.1 Frequency error for V2X
6.4E.1.0 Minimum conformance requirements
For intra-band V2X operating UE, the requirement shall apply on each component carrier as defined in clause 6.5.1G in TS 36.101 [5] and in clause 6.4E.1 in TS 38.101-1 [2], respectively.
For the inter-band con-current NR V2X operation, the requirements specified in subclause 6.4.1 of TS 36.101 [5] shall apply for the E-UTRA uplink in licensed band and the requirements specified in subclause 6.4E.1 of TS 38.101-1 [2] shall apply for the sidelink in NR Band n47.
The normative reference for this requirement is TS 38.101-3 [4] clause 6.4E.1.
6.4E.1.1 Frequency error for Intra-band V2X
6.4E.1.1.1 Test purpose
This test verifies the ability of both, the receiver and the transmitter, to process frequency correctly.
Receiver: to extract the correct frequency from the stimulus signal, offered by the System simulator, under ideal propagation conditions and low level.
Transmitter: to derive the correct modulated carrier frequency from the results, gained by the receiver.
6.4E.1.1.2 Test applicability
No exception requirements applicable to NR V2X operation or E-UTRA V2X operation. Given only single switched SL is supported as per clause 6.4E.1.0. The requirements in this test case can be well covered in clause 6.5.1G of TS 36.521-1 [10] and clause 6.4E.1 of TS 38.521-1 [8] and don’t need to be tested again.
6.4E.1.2 Frequency error for Inter-band V2X
6.4E.1.2.1 Test purpose
Same test purpose as in clause 6.4E.1 in TS 38.521-1 [8].
6.4E.1.2.2 Test applicability
For inter-band V2X operation, no exception requirements are specified for the E-UTRA/NR Uu carrier and E-UTRA/NR SL carrier.
For inter-band V2X configuration with E-UTRA Uu and NR sidelink, the requirements in this test case can be well covered in clause 6.5.1 of TS 36.521-1 [10] for E-UTRA Uu carrier and clause 6.4E.1.1 of TS 38.521-1 [8] and don’t need to be tested again.
6.4E.2 Transmit modulation quality for V2X
6.4E.2.1 Error Vector Magnitude for V2X
6.4E.2.1.0 Minimum conformance requirements
For intra-band V2X operating UE, the requirement shall apply on each SL transmission as defined in clause 6.5.2G.1 in TS 36.101 [5] and in clause 6.4E.2.1 in TS 38.101-1 [2], respectively.
For the inter-band con-current NR V2X operation, the requirements specified in subclause 6.5.2 of TS 36.101 [5] shall apply for the E-UTRA uplink in licensed band and the requirements specified in subclause 6.4E.2.1 of TS 38.101-1 [2] shall apply for the sidelink in NR Band n47.
The normative reference for this requirement is TS 38.101-3 [4] clause 6.4E.2.1.1.
6.4E.2.1.1 Error Vector Magnitude for intra-band V2X
6.4E.2.1.1.1 Test purpose
Same test purpose as in clause 6.4E.2 in TS 38.521-1 [8].
6.4E.2.1.1.2 Test applicability
No exception requirements applicable to NR V2X operation or E-UTRA V2X operation. Given only single switched SL is supported as per clause 6.4E.2.1.0. The requirements in this test case can be well covered in clause 6.5.2.1G of TS 36.521-1 [10] and clause 6.4E.2.1 of TS 38.521-1 [8] and don’t need to be tested again.
6.4E.2.1.2 Error Vector Magnitude for Inter-band V2X
6.4E.2.1.2.1 Test purpose
Same test purpose as in clause 6.4E.2 in TS 38.521-1 [8].
6.4E.2.1.2.2 Test applicability
For inter-band V2X operation, no exception requirements are specified for the E-UTRA/NR Uu carrier and E-UTRA/NR SL carrier.
For inter-band V2X configuration with E-UTRA Uu and NR sidelink, the requirements in this test case can be well covered in clause 6.5.2.1 of TS 36.521-1 [10] for E-UTRA Uu carrier and clause 6.4E.2.2.1 of TS 38.521-1 [8] and don’t need to be tested again.
6.4E.2.2 Carrier leakage for V2X
6.4E.2.2.0 Minimum conformance requirements
For intra-band V2X operating UE, the requirement shall apply on each SL transmission as defined in clause 6.5.2G.2 in TS 36.101 [5] and in clause 6.4E.2.2 in TS 38.101-1 [2], respectively.
The normative reference for this requirement is TS 38.101-3 [4] clause 6.4E.2.2.2.
6.4E.2.2.1 Carrier leakage for intra-band V2X
6.4E.2.2.1.1 Test purpose
Same test purpose as in clause 6.4E.2.3.1 in TS 38.521-1 [8].
6.4E.2.2.1.2 Test applicability
No exception requirements applicable to NR V2X operation or E-UTRA V2X operation. Given only single switched SL is supported as per clause 6.2E.1.0. The requirements in this test case can be well covered in clause 6.5.2.2G of TS 36.521-1 [10] and clause 6.4E.2.3 of TS 38.521-1 [8] and don’t need to be tested again.
6.4E.2.3 In-band emissions for V2X
6.4E.2.3.0 Minimum conformance requirements
For intra-band V2X operating UE, the requirement shall apply on each SL transmission as defined in clause 6.5.2G.3 in TS 36.101 [5] and in clause 6.4E.2.3 in TS 38.101-1 [2], respectively.
The normative reference for this requirement is TS 38.101-3 [4] clause 6.4E.2.2.3.
6.4E.2.3.1 In-band emissions for intra-band V2X
6.4E.2.3.1.1 Test purpose
Same test purpose as in clause 6.4E.2.4.1 in TS 38.521-1 [8].
6.4E.2.3.1.2 Test applicability
No exception requirements applicable to NR V2X operation or E-UTRA V2X operation. Given only single switched SL is supported as per clause 6.2E.1.0. The requirements in this test case can be well covered in clause 6.5.2.3G of TS 36.521-1 [10] and clause 6.4E.2.4 of TS 38.521-1 [8] and don’t need to be tested again.