5 Operating bands and channel arrangement

38.521-33GPPNRPart 3: Range 1 and Range 2 Interworking operation with other radiosRadio transmission and receptionRelease 17TSUser Equipment (UE) conformance specification

5.1 General

The channel arrangements presented in this clause are based on the operating bands and channel bandwidths defined in the present release of specifications.

NOTE: Other operating bands and channel bandwidths may be considered in future releases.

Requirements throughout the RF specifications are in many cases defined separately for different frequency ranges (FR). The frequency ranges in which NR can operate according to this version of the specifications are identified as described in Table 5.1-1.

Table 5.1-1: Definition of frequency ranges

Frequency range designation

Corresponding frequency range

FR1

410 MHz – 7125 MHz

FR2

24250 MHz – 52600 MHz

The present specification covers band combinations including

– at least one FR1 operating band and one FR2 operating band for carrier aggregation and dual connectivity operations;

– at least one E-UTRA operating band for dual connectivity operations.

5.2 Operating bands

NR is designed to operate in FR1 operating bands defined in TS 38.101-1 [2] and FR2 operating bands defined in TS 38.101-2 [3]. E-UTRA is designed to operate in operating bands defined in TS 36.101 [4].

5.2A Operating bands for CA

5.2A.1 Inter-band CA between FR1 and FR2

NR carrier aggregation is designed to operate in the operating bands defined in Table 5.2A.1‑1. The band combinations include at least one FR1 operating band and one FR2 operating band.

If the mandatory simultaneous Rx/Tx capability applies for a band combination, the mandatory simultaneous Rx/Tx capability also applies for the band combination when the applicable band combination is a subset of a higher order band combination.

Table 5.2A.1-1: Band combinations for inter-band NR CA between FR1 and FR2

NR CA Band

NR Band

CA_n8-n2581

n8, n258

CA_n71-n2571

n71, n257

CA_n77-n2571

n77, n257

CA_n78-n2571

n78, n257

CA_n79-n2571

n79, n257

NOTE 1: Applicable for UE supporting inter-band carrier aggregation with mandatory simultaneous Rx/Tx capability.

5.2B Operating bands for DC

5.2B.1 General

The operating bands are specified in clause 5.5B for operation with EN-DC, NGEN-DC, NE-DC or NR-DC configured.

5.2B.2 to 5.2B.7 Void

5.2E Operating bands for V2X

5.2E.1 Intra-band V2X bands

NR V2X operation is designed to operate with E-UTRA sidelink in TDM mode on the operating bands combinations listed in Table 5.2E.1-1.

Table 5.2E.1-1: Intra-band V2X operating bands

E-UTRA V2X-NR V2X Band combination

E-UTRA or NR Band

Interface

V2X_47_n471

47

PC5

n47

PC5

NOTE 1: Only single switched SL is supported.

5.2E.2 Inter-band V2X bands

NR V2X operation is designed to operate concurrent with E-UTRA uplink/downlink on the operating bands combinations listed in Table 5.2E.2-1.

Table 5.2E.2-1: Inter-band con-current V2X operating bands

E-UTRA-NR V2X Band Combination

E-UTRA or NR Band

Interface

V2X_20_n38

20

Uu

n38

PC5

V2X_n71_47

47

PC5

n71

Uu

V2X_n71_(n) 471

47

PC5

n47

PC5

n71

Uu

NOTE 1: Only single switched SL in ITS band is supported.

5.3 UE Channel bandwidth

5.3A UE Channel bandwidth for CA

5.3A.1 Inter-band CA between FR1 and FR2

For inter-band NR CA between FR1 and FR2, a carrier aggregation configuration is a combination of operating bands, each supporting a carrier aggregation bandwidth class as specified in clause 5.3A.5 of TS 38.101-1 [2] and clause 5.3A.4 of TS 38.101-2 [3] independently.

5.3B UE Channel bandwidth for EN-DC

5.3B.0 General

For intra-band contiguous EN-DC, the aggregated channel bandwidth is sum of the individual NR and E-UTRA channel bandwidths assuming nominal EN-DC channel with 0 kHz offset spacing as specified in clause 5.4.

ENBW = BWNR_Channel + BWE-UTRA_Channel

In the case where the NR sub-block and/or the E-UTRA sub-block itself is composed of intra-band contiguous CA carriers, the EN-DC aggregated channel bandwidth is the sum of the aggregated channel bandwidths of the NR and E-UTRA sub-blocks assuming nominal EN-DC channel spacing between the NR sub-block and E-UTRA sub-block.

ENBW = BWNR_Channel_CA + BWE-UTRA_Channel_CA

For NR inter-band dual connectivity specified in 5.5B.7, the corresponding NR CA configurations in 5.5A.1, i.e., dual uplink inter-band carrier aggregation between FR1 and FR2 with uplink assigned to two NR bands, are applicable to Dual Connectivity.

NOTE: Requirements for the dual connectivity configurations are defined in the clause corresponding NR uplink CA between FR1 and FR2 configurations, unless otherwise specified.

Intra-band contiguous EN-DC configurations are defined using intra-band contiguous EN-DC bandwidth class notation DC_(n)Xyz where the first EN-DC bandwidth class letter indicates the number of contiguous E-UTRA carriers and the second EN-DC bandwidth class letter indicates the number of contiguous NR carriers for the EN-DC combination of E-UTRA Band X and NR Band nX. Applicable contiguous intraband EN-DC bandwidth classes are listed in Table 5.3B.0-1

Table 5.3B.0-1: Intra-band contiguous EN-DC bandwidth classes

Intra-band contiguous EN-DC bandwidth class

Number of contiguous CC

E-UTRA

NR

AA

1

1

AB

1

2

CA

2

1

DA

3

1

5.3B.1 Intra-band EN-DC in FR1

5.3B.1.1 General

The requirements for intra-band EN-DC in this specification are defined for EN-DC configurations with associated bandwidth combination sets.

For each EN-DC configuration, requirements are specified for all bandwidth combinations contained in a bandwidth combination set, which is indicated per supported band combination in the UE radio access capability. A UE can indicate support of several bandwidth combination sets per band combination.

5.3B.1.2 BCS for Intra-band contiguous EN-DC

For intra-band contiguous EN-DC, an EN-DC configuration is a single operating band supporting an intra-band contiguous EN-DC bandwidth class.

Bandwidth combination sets for intra-band contiguous EN-DC are specified in Table 5.3B.1.2-1. The EN-DC configurations and bandwidth combination sets in Table 5.3B.1.2-1 also apply to higher order EN-DC combinations that include inter-band and intra-band EN-DC on the downlink and inter-band EN-DC on the uplink. If no BCS is reported in the UE capabilities for an intra-band combination the default is that the UE supports BCS0.

Table 5.3B.1.2-1: EN-DC configurations and bandwidth combination sets defined for intra-band contiguous EN-DC

E-UTRA – NR configuration / Bandwidth combination set

Downlink

EN-DC configuration

Uplink EN-DC configurations

Component carriers in order of increasing carrier frequency

Maximum aggregated
bandwidth (MHz)

Bandwidth combination set

Channel bandwidths for E-UTRA carrier (MHz)

Channel bandwidths for NR carrier (MHz)

Channel bandwidths for E-UTRA carrier (MHz)

DC_(n)41AA

DC_(n)41AA

20

40, 60, 80,100

120

0

40, 60, 80,100

20

20

40, 50, 60, 80,100

120

1

40, 50, 60, 80,100

20

DC_(n)41CA

DC_(n)41AA, DC_41A_n41A

20+20

40, 60, 80,100

140

0

40, 60, 80,100

20+20

20+20

40, 50, 60, 80,100

140

1

40, 50, 60, 80,100

20+20

DC_(n)41DA

DC_(n)41AA, DC_41A_n41A

20+20+20

40, 60, 80,100

160

0

40, 60, 80,100

20+20+20

20+20+20

40, 50, 60, 80,100

160

1

40, 50, 60, 80,100

20+20+20

DC_(n)71AA

DC_(n)71AA

15

5

20

0

10

5, 10

5

5, 10, 15

5

15

5, 10

10

5, 10, 15

5

NOTE 1: Void

NOTE 2: Void

NOTE 3: Void

NOTE 4: The channel bandwidths for E-UTRA or NR carrier should be at least supported in one of the BCS indicated in E-UTRA bandwidth combination sets or NR bandwidth combination sets if reported.

5.3B.1.3 BCS for Intra-band non-contiguous EN-DC

For intra-band non-contiguous EN-DC, an EN-DC configuration is a single operating band supporting E-UTRA and NR carriers, where E-UTRA configuration is indicated by using E-UTRA CA bandwidth class as defined in TS 36.101 [5] and NR configuration is indicated by using NR CA bandwidth class as defined in TS 38.101-1 [2].

Requirements for intra-band non-contiguous EN-DC are defined for the EN-DC configurations and bandwidth combination sets specified in Table 5.3B.1.3-1. The EN-DC configurations and bandwidth combination sets in Table 5.3B.1.3-1 also apply to higher order EN-DC combinations that include inter-band and intra-band EN-DC on the downlink and inter-band EN-DC on the uplink. If no BCS is reported in the UE capabilities for an intra-band combination the default is that the UE supports BCS0.

Table 5.3B.1.3-1: EN-DC configurations and bandwidth combination sets defined for intra-band non-contiguous EN-DC

E-UTRA – NR configuration / Bandwidth combination set

Downlink

EN-DC configuration

Uplink EN-DC configurations

Component carriers in order of increasing carrier frequency

Maximum aggregated
bandwidth (MHz)

Bandwidth combination set

Channel bandwidths for E-UTRA carrier (MHz)

Channel bandwidths for NR carrier (MHz)

Channel bandwidths for E-UTRA carrier (MHz)

DC_3A_n3A

DC_3A_n3A(1)

5, 10, 15, 20, 25, 30

5, 10, 15, 20

50

0

DC_41A_n41A

DC_41A_n41A

20

40, 60, 80,100

120

0

40, 60, 80,100

20

20

40, 50, 60, 80,100

120

1

40, 50, 60, 80,100

20

DC_41C_n41A

DC_41A_n41A

20+20

40, 60, 80,100

140

0

40, 60, 80,100

20+20

20+20

40, 50, 60, 80,100

140

1

40, 50, 60, 80,100

20+20

DC_41D_n41A

DC_41A_n41A

20+20+20

40, 60, 80,100

160

0

40, 60, 80,100

20+20+20

20+20+20

40, 50, 60, 80,100

160

1

40, 50, 60, 80,100

20+20+20

NOTE 1: Only single switched UL is supported in Rel-15.

5.3E UE Channel bandwidth for V2X

5.3E.0 General

The requirements specified in clause 5.3B are applicable to NR V2X UE.

5.3E.1 Intra-band contiguous V2X in FR1

For intra-band contiguous E-UTRA NR V2X UE, an EN-DC bandwidth class in Table 5.3B.0-1 are considered to specify the V2X transmission/reception configurations.

Bandwidth combination sets and V2X transmission/reception configurations for intra-band contiguous V2X UE are specified in Table 5.3E.1-1.

Table 5.3E.1-1: E-UTRA-NR V2X configurations and bandwidth combination sets for intra-band contiguous V2X UE

V2X configuration

SL transmission band

Channel bandwidths for E-UTRA carrier (MHz)

Channel bandwidths for NR carrier (MHz)

Maximum aggregated
bandwidth (MHz)

Bandwidth combination set

V2X_(n)47AA

E-UTRA Band 47 or NR band n47

10

10,20,30,40

60

0

20

10,20,30,40

5.3E.2 Intra-band non-contiguous V2X in FR1

For intra-band non-contiguous E-UTRA NR V2X UE, an EN-DC bandwidth class in Table 5.3B.0-1 are considered to specify the V2X transmission/reception configurations.

Bandwidth combination sets and SL transmission/reception configurations for intra-band non-contiguous V2X are specified in Table 5.3E.2-1.

Table 5.3E.2-1: E-UTRA-NR V2X configurations and bandwidth combination sets for intra-band non-contiguous V2X UE

V2X configuration

SL transmission band

Channel bandwidths for E-UTRA carrier (MHz)

Channel bandwidths for NR carrier (MHz)

Maximum aggregated
bandwidth (MHz)

Bandwidth combination set

V2X_47A_n47A

E-UTRA Band 47 or NR band n47

10

10,20,30,40

60

0

20

10,20,30,40

5.3E.3 Inter-band V2X in FR1

For inter-band E-UTRA NR V2X UE, the each channel bandwidth for inter-band V2X operations in FR1 is specified in TS 36.101 [4] and TS 38.101-1 [2], respectively.

5.4 Void

5.4A Channel arrangement for CA

The channel arrangement for CA operations in FR1 and FR2 as specified in TS 38.101-1 [2] and TS 38.101-2 [3], respectively.

5.4B Channel arrangement for DC

5.4B.0 General

The channel arrangement for intra-band EN-DC operations in FR1 is specified in TS 36.101 [5] and TS 38.101-1 [2], respectively.

5.4B.1 Channel spacing for intra-band EN-DC carriers

The spacing between carriers will depend on the deployment scenario, the size of the frequency block available and the channel bandwidths. The nominal channel spacing between E-UTRA carrier and an adjacent NR carrier for intra-band contiguous EN-DC is defined as following:

– For NR operating bands with 100 kHz channel raster,

Nominal Channel spacing = (BWE-UTRA_Channel + BWNR_Channel)/2

– For NR operating bands with 15 kHz channel raster,

Nominal Channel spacing = (BWE-UTRA_Channel + BWNR_Channel)/2+{-5kHz, 0kHz, 5kHz} for ∆FRaster equals to 15 kHz

Nominal Channel spacing = (BWE-UTRA_Channel + BWNR_Channel)/2+{-10kHz, 0kHz, 10kHz} for ∆FRaster equals to 30 kHz

where BWE-UTRA_Channel and BWNR_Channel are the channel bandwidths of the E-UTRA and NR carriers, ∆FRaster is the band dependent channel raster granularity defined in TS38.101-1[2]. The channel spacing can be adjusted depending on the channel raster to optimize performance in a particular deployment scenario.

For intra-band non-contiguous EN-DC the channel spacing between E-UTRA and NR carriers shall be larger than the nominal channel spacing defined in this clause.

5.5 Configuration

5.5A Configuration for CA

5.5A.1 Inter-band CA configurations between FR1 and FR2

Table 5.5A.1-1: Inter-band CA configurations and bandwidth combinations sets between FR1 and FR2 (two bands)

NR CA configuration

Uplink CA configuration

NR Band

Channel bandwidth (MHz) (NOTE 3)

Bandwidth combination set

5

10

15

20

25

30

40

50

60

70

80

90

100

200

400

CA_n1A-n258A

CA_n1A-n258A

n1

5

10

15

20

0

n258

50

100

200

400

n1

5

10

15

20

25

30

40

50

1

n258

50

100

200

400

CA_n1A-n258D

CA_n1A-n258A

n1

5

10

15

20

0

n258

CA_n258D

n1

5

10

15

20

25

30

40

50

1

n258

CA_n258D

CA_n1A-n258E

CA_n1A-n258A

n1

5

10

15

20

0

n258

CA_n258E

n1

5

10

15

20

25

30

40

50

1

n258

CA_n258E

CA_n1A-n258F

CA_n1A-n258A

n1

5

10

15

20

0

n258

CA_n258F

n1

5

10

15

20

25

30

40

50

1

n258

CA_n258F

CA_n1A-n258G

CA_n1A-n258A

n1

5

10

15

20

0

n258

CA_n258G

n1

5

10

15

20

25

30

40

50

1

n258

CA_n258G

CA_n1A-n258H

CA_n1A-n258A

n1

5

10

15

20

0

n258

CA_n258H

n1

5

10

15

20

25

30

40

50

1

n258

CA_n258H

CA_n1A-n258I

CA_n1A-n258A

n1

5

10

15

20

0

n258

CA_n258I

n1

5

10

15

20

25

30

40

50

1

n258

CA_n258I

CA_n1A-n258J

CA_n1A-n258A

n1

5

10

15

20

0

n258

CA_n258J

n1

5

10

15

20

25

30

40

50

1

n258

CA_n258J

CA_n1A-n258K

CA_n1A-n258A

n1

5

10

15

20

0

n258

CA_n258K

n1

5

10

15

20

25

30

40

50

1

n258

CA_n258K

CA_n1A-n258L

CA_n1A-n258A

n1

5

10

15

20

0

n258

CA_n258L

n1

5

10

15

20

25

30

40

50

1

n258

CA_n258L

CA_n1A-n258M

CA_n1A-n258A

n1

5

10

15

20

0

n258

CA_n258M

n1

5

10

15

20

25

30

40

50

1

n258

CA_n258M

CA_n8A-n258A

CA_n8A-n258A

n8

5

10

15

20

0

n258

50

100

200

400

CA_n71A-n257A

n71

5

10

15

20

0

n257

50

100

200

400

CA_n77A-n257A

CA_n77A-n257A

n77

10

15

20

40

50

60

80

90

100

0

n257

50

100

200

400

CA_n77A-n257D

CA_n77A-n257A

n77

10

15

20

40

50

60

80

90

100

0

n257

CA_n257D

CA_n77A-n257E

CA_n77A-n257A

n77

10

15

20

40

50

60

80

90

100

0

n257

CA_n257E

CA_n77A-n257F

CA_n77A-n257A

n77

10

15

20

40

50

60

80

90

100

0

n257

CA_n257F

CA_n77C-n257A

CA_n77A-n257A

n77

CA_n77C

0

n257

50

100

200

400

CA_n77C-n257D

CA_n77A-n257A

n77

CA_n77C

0

n257

CA_n257D

CA_n77C-n257E

CA_n77A-n257A

n77

CA_n77C

0

n257

CA_n257E

CA_n77C-n257F

CA_n77A-n257A

n77

CA_n77C

0

n257

CA_n257F

CA_n78A-n257A

CA_n78A-n257A

n78

10

15

20

40

50

60

80

90

100

0

n257

50

100

200

400

CA_n78A-n257D

CA_n78A-n257A

n78

10

15

20

40

50

60

80

90

100

0

n257

CA_n257D

CA_n78A-n257E

CA_n78A-n257A

n78

10

15

20

40

50

60

80

90

100

0

n257

CA_n257E

CA_n78A-n257F

CA_n78A-n257A

n78

10

15

20

40

50

60

80

90

100

0

n257

CA_n257F

CA_n78C-n257A

CA_n78A-n257A

n78

CA_n78C

0

n257

50

100

200

400

CA_n78C-n257D

CA_n78A-n257A

n78

CA_n78C

0

n257

CA_n257D

CA_n78C-n257E

CA_n78A-n257A

n78

CA_n78C

0

n257

CA_n257E

CA_n78C-n257F

CA_n78A-n257A

n78

CA_n78C

0

n257

CA_n257F

CA_n78A-n258D

CA_n78A-n258A

n78

10

15

20

40

50

60

80

90

100

0

n258

CA_n258D

n78

10

15

20

25

30

40

50

60

70

80

90

100

1

n258

CA_n258D

CA_n78A-n258E

CA_n78A-n258A

n78

10

15

20

40

50

60

80

90

100

0

n258

CA_n258E

n78

10

15

20

25

30

40

50

60

70

80

90

100

1

n258

CA_n258E

CA_n78A-n258F

CA_n78A-n258A

n78

10

15

20

40

50

60

80

90

100

0

n258

CA_n258F

n78

10

15

20

25

30

40

50

60

70

80

90

100

1

n258

CA_n258F

CA_n79A-n257A

CA_n79A-n257A

n79

40

50

60

80

100

0

n257

50

100

200

400

CA_n79A-n257D

CA_n79A-n257A

n79

40

50

60

80

100

0

n257

CA_n257D

CA_n79A-n257E

CA_n79A-n257A

n79

40

50

60

80

100

0

n257

CA_n257E

CA_n79A-n257F

CA_n79A-n257A

n79

40

50

60

80

100

0

n257

CA_n257F

CA_n79C-n257A

CA_n79A-n257A

n79

CA_n79C

0

n257

50

100

200

400

CA_n79C-n257D

CA_n79A-n257A

n79

CA_n79C

0

n257

CA_n257D

CA_n79C-n257E

CA_n79A-n257A

n79

CA_n79C

0

n257

CA_n257E

CA_n79C-n257F

CA_n79A-n257A

n79

CA_n79C

0

n257

CA_n257F

NOTE 1: Reserved.

NOTE 2: The CA configurations are given in Table 5.5A.1-1 of either TS 38.521-1 [8] or TS 38.521-2 [9] where unless otherwise stated BCS0 is referred to.

NOTE 3: The SCS of each channel bandwidth for NR FR1 and NR FR2 band refers to Table 5.3.5-1 of TS 38.521-1 [8] and TS 38.521-2 [9] respectively.

5.5B Configuration for DC

5.5B.1 General

The operating bands and bandwidth classes are specified for operation with EN-DC, NGEN-DC, NE-DC or NR-DC configured. The EN-DC, NE-DC or NGEN-DC band combinations include at least one E-UTRA operating band.

For EN-DC or NE-DC configurations indicated by column "Single Uplink allowed" (e.g., problematic band combinations as defined in TS 38.306 [16]) in tables in this clause the UE may indicate capability of not supporting simultaneous dual and triple uplink operation due to possible intermodulation interference to its own primary downlink channel bandwidth of PCell or PSCell if the intermodulation order is 2 or if the intermodulation order is 3 for the combinations when both operating bands are between 450 MHz – 960 MHz or between 1427 MHz – 2690 MHz.

In the case for EN-DC or NE-DC configurations listed in tables in this clause for which the intermodulation products caused by the dual and triple uplink operation fall into the receive band but do not interfere with its own primary downlink channel bandwidth of PCell or PSCell as defined in Annex I the UE is mandated to operate in dual and triple uplink mode. Single Uplink is also allowed for certain band combinations where intermodulation or reverse intermodulation products could create difficulty for meeting emission requirements.

For EN-DC combinations of order 3 or higher, "Single Uplink allowed" UL configurations captured in Table 5.5B.2-1, Table 5.5B.3-1, and Table 5.5B.4-1 apply.

Non‑contiguous resource allocation and almost contiguous allocation are not applicable for E‑UTRA or NR carrier part of intra‑band EN‑DC configuration.

If multiple UL DC configurations are listed for multiple DL DC configurations, valid uplink configurations are such that uplink does not have more carriers than downlink.

Non‑contiguous resource allocation and almost contiguous allocation are not applicable for E‑UTRA or NR carrier part of intra‑band EN‑DC configuration.

If the mandatory simultaneous Rx/Tx capability applies for a DC configuration, the mandatory simultaneous Rx/Tx capability also applies for the DC configuration when the applicable DC configuration is a subset of a higher order DC configuration.

5.5B.2 Intra-band contiguous EN-DC

Supported channel bandwidths for E-UTRA operating bands are defined in TS 36.521-1 [10] and for NR operating bands in TS 38.521-1 [8].

Table 5.5B.2-1: Intra-band contiguous EN-DC configurations

EN-DC Configuration

Uplink EN-DC configuration (NOTE 1)

Single UL allowed

DC_(n)41AA5

DC_(n)41CA5

DC_(n)41DA5

DC_(n)41AA

Yes3

DC_(n)41CA5

DC_(n)41DA5

DC_41A_n41A

Yes3

DC_(n)71AA2

DC_(n)71AA

No4

NOTE 1: Uplink EN-DC configurations are the configurations supported by the present release of specifications.

NOTE 2: Requirements in this specification apply for NR SCS of 15 kHz only.

NOTE 3: Single UL allowed due to potential emission issues, not self-interference.

NOTE 4: For UE(s) supporting dynamic power sharing it is mandatory to do dual simultaneous UL. For UE(s) not supporting dynamic power sharing single UL is allowed.

NOTE 5: The minimum requirements only apply for non-simultaneous Tx/Rx between all carriers.

5.5B.3 Intra-band non-contiguous EN-DC

Supported channel bandwidths for E-UTRA operating bands are defined in TS 36.521-1 [10] and for NR operating bands in TS 38.521-1 [8].

Table 5.5B.3-1: Intra-band non-contiguous EN-DC configurations

EN-DC Configuration

Uplink EN-DC configuration (NOTE 1)

Single UL allowed

DC_3A_n3A

DC_3A_n3A2,7

Yes2,7

DC_41A_n41A3

DC_41C_n41A3

DC_41D_n41A3

DC_41A_n41A

Yes4

DC_66A_n66A

DC_66A_n66A5

Yes5

NOTE 1: Uplink EN-DC configurations are the configurations supported by the present release of specifications.

NOTE 2: Only single switched UL is supported in Rel-15

NOTE 3: The minimum requirements only apply for non-simultaneous Tx/Rx between all carriers.

NOTE 4: Single UL allowed due to potential emission issues, not self-interference.

NOTE 5: Only single switched UL is supported.

NOTE 6: Reserve.

NOTE 7: Single UL allowed due to potential emission issues and self-interference.

5.5B.4 Inter-band EN-DC within FR1

Supported channel bandwidths for E-UTRA operating bands and CA configurations are defined in TS 36.521-1 [10] and for NR operating bands and CA configurations in TS 38.521-1 [8] and present document.

5.5B.4.1 Inter-band EN-DC configurations within FR1 (two bands)

Table 5.5B.4.1-1: Inter-band EN-DC configurations within FR1 (two bands)

EN-DC configuration

Uplink EN-DC configuration

(NOTE 1)

Single UL allowed

DL interruption allowed

(Note 14)

DC_1A_n3A

DC_1A_n3A

DC_1_n3

DC_1A_n5A

DC_1A_n5A

No

DC_1A_n7A

DC_1A_n7A

No

DC_1A_n28A

DC_1A_n28A

No

DC_1A_n40A

DC_1A_n40A

No

DC_1A_n51A

DC_1A_n51A

No

DC_1A_n77A7

DC_1A_n77C7

DC_1A_n77A

DC_1_n77

No

DC_1A_n78A7

DC_1A_n78C7

DC_1A_n78A

No

No

DC_1A-1A_n78A

DC_1A_n78A

No

DC_1A_n79A7

DC_1A_n79C7

DC_1A_n79A

No

No

DC_2A_n5A

DC_2A_n5A

No

DC_2A_n41A

DC_2C_n41A

DC_2A_n41A

DC_2C_n41A

No

DC_2A_n66A

DC_2A_n66A

DC_2_n66

DC_2A_n71A

DC_2A_n71A

No

DC_2A_n77A

DC_2A_n77A

DC_2_n77

DC_2A_n78A

DC_2A_n78A

DC_2_n78

DC_3A_n1A

DC_3A_n1A

DC_3_n1

DC_3A_n5A

DC_3A_n5A

DC_3_n5

DC_3A_n7A

DC_3A_n7A

No

DC_3A_n28A

DC_3A_n28A

No

DC_3A_n40A

DC_3A_n40A

No

DC_3A_n41A7

DC_3C_n41A

DC_3A_n41A

DC_3C_n41A

DC_3_n41

No

DC_3A_n51A

DC_3A_n51A

No

DC_3A_n77A7

DC_3A_n77C7

DC_3A_n77A

DC_3_n77

No

DC_3A_n78A7

DC_3A_n78C7

DC_3C_n78A7

DC_3A_n78A

DC_3_n78

No

DC_3A_n79A7

DC_3A_n79C7

DC_3A_n79A

No

No

DC_5A_n2A

DC_5A_n2A

No

DC_5A_n40A

DC_5A_n40A

No

DC_5A_n66A

DC_5A_n66A

DC_5_n66

DC_5A_n77A

DC_5A_n77A

No

DC_5A_n78A7

DC_5A_n78C7

DC_5A_n78A

No

No

DC_7A_n1A

DC_7A_n1A

No

DC_7A_n3A

DC_7A_n3A

No

DC_7A_n5A

DC_7A_n5A

DC_7_n5

DC_7A_n28A

DC_7A_n28A

No

DC_7A_n51A

DC_7A_n51A

No

DC_7A_n66A

DC_7C_n66A

DC_7A_n66A

No

DC_7A_n78A7

DC_7C_n78A7

DC_7A_n78A

No

DC_7A-7A_n78A7, 21

DC_7A_n78A21

No

DC_8A_n1A

DC_8A_n1A

No

DC_8A_n3A

DC_8A_n3A

No

DC_8A_n20A

DC_8A_n20A

Yes

DC_8A_n40A7

DC_8A_n40A

No

DC_8A_n41A7

DC_8A_n41C

DC_8A_n41A

No

No

DC_8A_n41(2A)

DC_8A_n41A

No

No

DC_8A_n77A7

DC_8A_n77A

No

No

DC_8A_n78A7

DC_8A_n78A

No

No

DC_8A_n79A7

DC_8A_n79A

No

No

DC_11A_n77A7

DC_11A_n77A

No

No

DC_11A_n78A7

DC_11A_n78A

No

No

DC_11A_n79A7

DC_11A_n79A

No

DC_12A_n5A

DC_12A_n5A

No

DC_12A_n66A

DC_12A_n66A

No

DC_12A_n78A

DC_12A_n78A

DC_12_n78

DC_13A_n2A

DC_13A_n2A

No

DC_13A_n66A

DC_13A_n66A

No

DC_13A_n77A

DC_13A_n77A

No

DC_14A_n2A

DC_14A_n2A

No

DC_14A_n66A

DC_14A_n66A

No

DC_18A_n77A7

DC_18A_n77A

No

No

DC_18A_n78A7

DC_18A_n78A

No

No

DC_18A_n79A7

DC_18A_n79A

No

DC_19A_n1A

DC_19A_n1A

No

DC_19A_n77A7

DC_19A_n77C7

DC_19A_n77A

No

DC_19A_n78A7

DC_19A_n78C7

DC_19A_n78A

No

No

DC_19A_n79A7

DC_19A_n79C7

DC_19A_n79A

No

No

DC_20A_n1A

DC_20A_n1A

No

DC_20A_n3A

DC_20A_n3A

No

DC_20A_n7A

DC_20A_n7A

DC_20_n7

DC_20A_n8A

DC_20A_n8A

DC_20_n8

DC_20A_n28A8,11,13

DC_20A_n28A

No

DC_20A_n51A

DC_20A_n51A

No

DC_20A_n77A7

DC_20A_n77A

No

DC_20A_n78A7

DC_20A_n78A

No

DC_21A_n1A

DC_21A_n1A

No

DC_21A_n28A17

DC_21A_n28A

DC_21_n28

DC_21A_n77A7

DC_21A_n77C7

DC_21A_n77A

No

DC_21A_n78A7

DC_21A_n78C7

DC_21A_n78A

No

No

DC_21A_n79A7

DC_21A_n79C7

DC_21A_n79A

No

No

DC_25A_n41A

DC_25A_n41A

No

DC_26A_n41A

DC_26A_n41A

No

DC_26A_n77A7

DC_26A_n77A

No

DC_26A_n78A7

DC_26A_n78A

No

DC_26A_n79A7

DC_26A_n79A

No

DC_28A_n3A

DC_28A_n3A

No

DC_28A_n5A8

DC_28A_n5A

No

DC_28A_n7A

DC_28A_n7A

No

DC_28A_n51A

DC_28A_n51A

No

DC_28A_n77A7

DC_28A_n77C7

DC_28A_n77A

No

No

DC_28A_n78A7

DC_28A_n78C7

DC_28A_n78A

No

No

DC_28A_n79A7

DC_28A_n79C7

DC_28A_n79A

No

DC_30A_n5A

DC_30A_n5A

No

DC_30A_n66A

DC_30A_n66A

No

DC_38A_n78A7

DC_38A_n78A

No

DC_39A_n41A3

DC_39C_n41A3

DC_39A_n41A

DC_39C_n41A

No

No

DC_39A_n78A5,7

DC_39A_n78A

No

DC_39A_n79A7

DC_39A_n79A

No

No

DC_40A_n1A

DC_40A_n1A

No

DC_40A_n41A3

DC_40A_n41A

No

DC_40A_n77A

DC_40A_n77A

No

DC_40A_n78A

DC_40C_n78A

DC_40A_n78A

DC_40C_n78A

No

DC_40A_n79A7,12

DC_40C_n79A7,12

DC_40A_n79A

No

No

DC_41A_n77A

DC_41C_n77A

DC_41A_n77A

No

DC_41A_n78A

DC_41C_n78A

DC_41A_n78A

No

DC_41A_n79A6,7

DC_41C_n79A6,7

DC_41A_n79A

No

No

DC_42A_n51A

DC_42A_n51A

No

DC_42A_n77A3,4,9,11

DC_42A_n77C3,4,9,11

DC_42C_n77A3,4,9,11

DC_42C_n77C3,4,9,11

DC_42D_n77A3,4,9,11

DC_42E_n77A3,4,9,11

N/A

N/A

DC_42A_n78A3,4,9,11

DC_42A_n78C3,4,9,11

DC_42C_n78A3,4,9,11

DC_42C_n78C3,4,9,11

DC_42D_n78A3,4,9,11

DC_42E_n78A3,4,9,11

N/A

N/A

DC_42A_n79A9,15

DC_42A_n79C9,15

DC_42C_n79A9,15

DC_42C_n79C9,15

DC_42D_n79A9,15

DC_42E_n79A9,15

N/A

N/A

DC_46A_n78A2

DC_46C_n78A2

DC_46D_n78A2

DC_46E_n78A2

N/A

N/A

DC_48A_n5A

DC_48A_n5A

No

DC_48A_n66A

DC_48A_n66A

No

DC_66A_n2A

DC_66A_n2A

DC_66_n2

DC_66A_n5A

DC_66A_n5A

DC_66_n5

DC_66A_n41A

DC_66A_n41A

No

DC_66A_n71A

DC_66A_n71A

No

DC_66A_n78A

DC_66A_n78A

No

NOTE 1: Uplink EN-DC configurations are the configurations supported by the present release of specifications.

NOTE 2: Restricted to E-UTRA operation when inter-band carrier aggregation is configured. The downlink operating band for Band 46 is paired with the uplink operating band (external E-UTRA band) of the carrier aggregation configuration that is supporting the configured PCell.

NOTE 3: The minimum requirements apply only when there is non-simultaneous Tx/Rx operation between E-UTRA and NR carriers. This restriction applies also for these carriers when applicable EN-DC configuration is part of a higher order EN-DC configuration.

NOTE 4: For UEs not indicating interBandMRDC-WithOverlapDL-Bands-r16, the minimum requirements for intra-band non-contiguous EN-DC apply for the Band 42/48 and Band n77/n78 combination. For UEs not indicating interBandMRDC-WithOverlapDL-Bands-r16, when UE capability interBandContiguousMRDC is indicated, the minimum requirements for intra-band-contiguous EN-DC also should be met in addition to intra-band non-contiguous EN-DC. The intra-band requirements also apply for these carriers when applicable EN-DC configuration is a subset of a higher order EN-DC configuration.

NOTE 5: The frequency range above 3600 MHz for Band n78 is not used in this combination.

NOTE 6: The frequency range below 2506 MHz for Band 41 is not used in this combination.

NOTE 7: Applicable for UE supporting inter-band EN-DC with mandatory simultaneous Rx/Tx capability.

NOTE 8: The frequency range in band n28 is restricted for this band combination to 703 – 733 MHz for the UL and 758-788 MHz for the DL.

NOTE 9: The combination is not used alone as fall back mode of other band combinations in which UL in Band 42 is not used.

NOTE 10: Void.

NOTE 11: For UEs not indicating interBandMRDC-WithOverlapDL-Bands-r16, the minimum requirements for inter-band EN-DC apply when the maximum power spectral density imbalance between downlink carriers is within 6 dB. For UEs indicating interBandMRDC-WithOverlapDL-Bands-r16, the power imbalance requirement defined in clause 7.6B.2.6 of 38.101-3 [4] apply. For these UEs, the power spectral density imbalance condition also applies for these carriers when applicable EN-DC configuration is a subset of a higher order EN-DC configuration.

NOTE 12: Applicable for frequency range above 4800 MHz for Band n79 in this combination.

NOTE 13: For UEs not indicating interBandMRDC-WithOverlapDL-Bands-r16, the minimum requirements apply for synchronized DL carriers with a maximum receive time difference ≤ 3 usec. The requirements also apply for these carriers when applicable EN-DC configuration is a subset of a higher order EN-DC configuration.

NOTE 14: Applicable when dynamic switching between two uplink carriers is conducted. The DL interruption requirements for NR DL carrier(s) and E-UTRA DL carrier(s) are specified in clause 8.2.1.2.14 of 38.133 [25] and clause 7.32.2.12 of 36.133 [12] respectively.

NOTE 15: Simultaneous Rx/Tx capability does not apply for UEs supporting band 42 with a n77 implementation only. Same restrictions are applied to related higher order configurations.

NOTE 16: Reserved.

NOTE 17: The frequency range in band n28 is restricted for this band combination to 728 – 738 MHz for the UL and 783 – 793 MHz for the DL. This restriction applies also for these band combinations when applicable EN-DC configuration is part of a higher order EN-DC configuration. Test Frequencies as specified in TS 38.508-1 [6] clause 4.3.1.

NOTE 18: Reserved.

NOTE 19: Reserved.

NOTE 20: Reserved.

NOTE 21: PC3 or PC2 Uplink EN-DC configuration is applicable to EN-DC configurations.

5.5B.4.2 Inter-band EN-DC configurations within FR1 (three bands)

Table 5.5B.4.2-1: Inter-band EN-DC configurations within FR1 (three bands)

EN-DC configuration

Uplink EN-DC configuration (NOTE 1)

DC_1A-3A_n28A

DC_1A_n28A

DC_3A_n28A

DC_1A-3A_n77A5

DC_1A-3A_n77C5

DC_1A_n77A

DC_3A_n77A

DC_1A-3A_n78A5

DC_1A-3A_n78C5

DC_1A-3C_n78A5

DC_1A_n78A

DC_3A_n78A

DC_3C_n78A

DC_1A-1A-3A_n78A

DC_1A-1A-3C_n78A

DC_1A_n78A

DC_3A_n78A

DC_3C_n78A

DC_1A-3C_n78(2A)5

DC_1A_n78A

DC_3A_n78A

DC_3C_n78A

DC_1A-3A_n79A5

DC_1A-3A_n79C5

DC_1A_n79A

DC_3A_n79A

DC_1A-5A_n78A5

DC_1A-5A_n78C5

DC_1A_n78A

DC_5A_n78A

DC_1A-1A-5A_n78A

DC_1A_n78A

DC_5A_n78A

DC_1A-7A_n3A

DC_1A_n3A

DC_7A_n3A

DC_1A-7A_n28A5

DC_1A_n28A

DC_7A_n28A

DC_1A-7A_n78A5

DC_1A_n78A

DC_7A_n78A

DC_1A-7A-7A_n78A5

DC_1A_n78A

DC_7A_n78A

DC_1A-8A_n3A

DC_1A_n3A

DC_8A_n3A

DC_1A-8A_n78A5

DC_1A_n78A

DC_8A_n78A

DC_1A-8A_n78(2A)5

DC_1A_n78A

DC_8A_n78A

DC_1A-18A_n77A5

DC_1A_n77A

DC_18A_n77A

DC_1A-18A_n78A5

DC_1A_n78A

DC_18A_n78A

DC_1A-18A_n79A

DC_1A_n79A

DC_18A_n79A

DC_1A-19A_n77A5

DC_1A-19A_n77C5

DC_1A_n77A

DC_19A_n77A

DC_1A-19A_n78A5

DC_1A-19A_n78C5

DC_1A_n78A

DC_19A_n78A

DC_1A-19A_n79A5

DC_1A-19A_n79C5

DC_1A_n79A

DC_19A_n79A

DC_1A-20A_n3A

DC_1A_n3A

DC_20A_n3A

DC_1A-20A_n8A

DC_1A_n8A

DC_20A_n8A

DC_1A-20A_n28A6,11,12

DC_1A_n28A

DC_20A_n28A

DC_1A-20A_n78A5

DC_1A_n78A

DC_20A_n78A

DC_1A-21A_n77A5

DC_1A-21A_n77C5

DC_1A_n77A

DC_21A_n77A

DC_1A-21A_n78A5

DC_1A-21A_n78C5

DC_1A_n78A

DC_21A_n78A

DC_1A-21A_n79A5

DC_1A-21A_n79C5

DC_1A_n79A

DC_21A_n79A

DC_1A-28A_n3A

DC_1A_n3A

DC_28A_n3A

DC_1A-28A_n5A6

DC_1A_n5A

DC_28A_n5A

DC_1A-28A_n77A5

DC_1A-28A_n77C5

DC_1A_n77A

DC_28A_n77A

DC_1A-28A_n78A5

DC_1A-28A_n78C5

DC_1A_n78A

DC_28A_n78A

DC_1A_n28A-n78A5

DC_1A_n28A

DC_1A_n78A

DC_1A-28A_n79A

DC_1A-28A_n79C

DC_1A_n79A

DC_28A_n79A

DC_1A-41A_n28A5

DC_1A-41C_n28A5

DC_1A_n28A

DC_41A_n28A

DC_41C_n28A

DC_1A-41A_n77A

DC_1A-41C_n77A

DC_1A_n77A

DC_41A_n77A

DC_1A-41A_n78A

DC_1A-41C_n78A

DC_1A_n78A

DC_41A_n78A

DC_1A-41C_n79A

DC_1A_n79A

DC_1A-42A_n77A10,11

DC_1A-42A_n77C10,11

DC_1A-42C_n77A10,11

DC_1A-42C_n77C10,11

DC_1A-42D_n77A10,11

DC_1A-42E_n77A10,11

DC_1A_n77A

DC_1A-42A_n78A10,11

DC_1A-42A_n78C10,11

DC_1A-42C_n78A10,11

DC_1A-42C_n78C10,11

DC_1A-42D_n78A10,11

DC_1A-42E_n78A10,11

DC_1A_n78A

DC_1A-42A_n79A

DC_1A-42A_n79C

DC_1A-42C_n79A

DC_1A-42C_n79C

DC_1A-42D_n79A

DC_1A-42E_n79A

DC_1A_n79A

DC_1A_n77A-n79A

DC_1A_n77A

DC_1A_n79A

DC_1A_n78A-n79A

DC_1A_n78A

DC_1A_n79A

DC_1A_SUL_n78A-n84A5

DC_1A_n78A

DC_1A_n84A_ULSUP-TDM_n78A

DC_1A_n84A_ULSUP-FDM_n78A

DC_2A-5A_n66A

DC_2A_n66A

DC_5A_n66A

DC_2A-12A_n66A

DC_2A_n66A

DC_12A_n66A

DC_2A-13A_n77A

DC_2A_n77A

DC_13A_n77A

DC_2A-14A_n2A

DC_2A_n2A2

DC_14A_n2A

DC_2A-14A_n66A

DC_2A_n66A

DC_14A_n66A

DC_2A-2A-14A_n66A

DC_2A_n66A

DC_14A_n66A

DC_2A-30A_n66A

DC_2A_n66A

DC_30A_n66A

DC_2A-66A_n5A

DC_2A_n5A

DC_66A_n5A

DC_2A-66A_n41A

DC_2A_n41A

DC_66A_n41A

DC_2A-66A_n71A

DC_2A_n71A

DC_66A_n71A

DC_2A-66A_n77A

DC_2A_n77A

DC_66A_n77A

DC_2A-(n)71AA

DC_2A_n71A

DC_(n)71AA

DC_3A_n1A-n78A5

DC_3A_n1A

DC_3A_n78A

DC_3A_n1A-n79A5

DC_3A_n1A

DC_3A_n79A

DC_3A_n3A-n77A

DC_3A_n77A

DC_3A_n3A2

DC_3A_n3A-n78A

DC_3A_n78A

DC_3A_n3A2

DC_3A-5A_n78A5

DC_3A-5A_n78C5

DC_3A_n78A

DC_5A_n78A

DC_3A-7A_n5A

DC_3A_n5A

DC_7A_n5A

DC_3A-7A_n28A

DC_3A_n28A

DC_7A_n28A

DC_3A-7A_n78A5

DC_3C-7A_n78A5

DC_3A_n78A

DC_7A_n78A

DC_3A-7C_n78A5

DC_3C-7C_n78A5

DC_3A_n78A

DC_7A_n78A

DC_3A-7A-7A_n78A5

DC_3A_n78A

DC_7A_n78A

DC_3A-8A_n1A

DC_3A_n1A

DC_8A_n1A

DC_3A-8A_n28A

DC_3A_n28A

DC_8A_n28A

DC_3A-8A_n78A5

DC_3A_n78A

DC_8A_n78A

DC_3A-18A_n77A

DC_3A_n77A

DC_18A_n77A

DC_3A-8A_n78(2A)

DC_3A_n78A

DC_8A_n78A

DC_3A-18A_n78A

DC_3A_n78A

DC_18A_n78A

DC_3A-19A_n77A5

DC_3A-19A_n77C5

DC_3A_n77A

DC_19A_n77A

DC_3A-19A_n78A5

DC_3A-19A_n78C5

DC_3A_n78A

DC_19A_n78A

DC_3A-19A_n79A5

DC_3A-19A_n79C5

DC_3A_n79A

DC_19A_n79A

DC_3A-20A_n1A

DC_3A_n1A

DC_20A_n1A

DC_3A-20A_n28A5,6,11,12

DC_3A_n28A

DC_20A_n28A

DC_3A-20A_n78A5

DC_3C-20A_n78A5

DC_3A_n78A

DC_20A_n78A

DC_3A-21A_n77A5

DC_3A-21A_n77C5

DC_3A_n77A

DC_21A_n77A

DC_3A-21A_n78A5

DC_3A-21A_n78C5

DC_3A_n78A

DC_21A_n78A

DC_3A-21A_n79A5

DC_3A-21A_n79C5

DC_3A_n79A

DC_21A_n79A

DC_3A-28A_n77A

DC_3A-28A_n77C

DC_3A_n77A

DC_28A_n77A

DC_3A-28A_n78A5

DC_3A-28A_n78C5

DC_3A_n78A

DC_28A_n78A

DC_3A_n28A-n78A5

DC_3A_n28A

DC_3A_n78A

DC_3A-28A_n79A

DC_3A-28A_n79C

DC_3A_n79A

DC_28A_n79A

DC_3A-38A_n78A

DC_3A_n78A

DC_3A-40A_n1A

DC_3A_n1A

DC_40A_n1A

DC_3A-41A_n28A5

DC_3A-41C_n28A5

DC_3A_n28A

DC_41A_n28A

DC_41C_n28A

DC_3A-41A_n41A

DC_3A_n41A

DC_3A-41A_n77A

DC_3A-41C_n77A

DC_3A_n77A

DC_41A_n77A

DC_3A-41A_n77(2A)

DC_3A_n77A

DC_41A_n77A

DC_3A-41A_n78A

DC_3A_n78A

DC_41A_n78A

DC_3A-42A_n77A10,11

DC_3A-42A_n77C10,11

DC_3A-42C_n77A10,11

DC_3A-42C_n77C10,11

DC_3A-42D_n77A10,11

DC_3A-42E_n77A10,11

DC_3A_n77A

DC_3A-42A_n78A10,11

DC_3A-42A_n78C10,11

DC_3A-42C_n78A10,11

DC_3A-42C_n78C10,11

DC_3A-42D_n78A10,11

DC_3A-42E_n78A10,11

DC_3A_n78A

DC_3A-42A_n79A

DC_3A-42A_n79C

DC_3A-42C_n79A

DC_3A-42C_n79C

DC_3A-42D_n79A

DC_3A-42E_n79A

DC_3A_n79A

DC_3A_n77A-n79A

DC_3A_n77A

DC_3A_n79A

DC_3A_n78A-n79A

DC_3A_n78A

DC_3A_n79A

DC_3A_SUL_n78A-n80A5

DC_3A_n78A

DC_3A_n80A_ULSUP-TDM_n78A

DC_3A_n80A_ULSUP-FDM_n78A

DC_3A_SUL_n78A-n82A5

DC_3A_n78A

DC_3A_n82A

DC_3A_SUL_n79A-n80A5

DC_3A_n79A

DC_3A_n80A_ULSUP-TDM_n79A

DC_3A_n80A_ULSUP-FDM_n79A

DC_5A-7A_n78A

DC_5A_n78A

DC_7A_n78A

DC_5A-7A-7A_n78A

DC_5A_n78A

DC_7A_n78A

DC_5A-30A_n66A

DC_5A_n66A

DC_30A_n66A

DC_7A_n5A-n78A

DC_7C_n5A-n78A

DC_7A_n5A

DC_7C_n5A

DC_7A_n78A

DC_7C_n78A

DC_7A-8A_n1A

DC_7A_n1A

DC_8A_n1A

DC_7A-8A_n3A

DC_7A_n3A

DC_8A_n3A

DC_7A-20A_n1A

DC_7A_n1A

DC_20A_n1A

DC_7A-20A_n3A

DC_7A_n3A

DC_20A_n3A

DC_7A-20A_n8A

DC_7A_n8A

DC_20A_n8A

DC_7A-20A_n28A6,11,12

DC_7A_n28A

DC_20A_n28A

DC_7A-20A_n78A5

DC_7A_n78A

DC_20A_n78A

DC_7A-28A_n3A

DC_7A_n3A

DC_28A_n3A

DC_7A-28A_n5A6

DC_7A_n5A

DC_28A_n5A

DC_7A-28A_n78A5

DC_7A_n78A

DC_28A_n78A

DC_7C-28A_n78A5

DC_7A_n78A

DC_28A_n78A

DC_7A_n28A-n78A5

DC_7C_n28A-n78A

DC_7A_n28A

DC_7A_n78A

DC_7C_n28A

DC_7C_n78A

DC_7A-46A_n78A3

DC_7A-46C_n78A3

DC_7A-46D_n78A3

DC_7A-46E_n78A3

DC_7A_n78A

DC_8A_SUL_n78A-n81A5

DC_8A_n78A

DC_8A_n81A_ULSUP-TDM_n78A

DC_8A_n81A_ULSUP-FDM_n78A

DC_8A_SUL_n79A-n81A5

DC_8A_n79A

DC_8A_n81A_ULSUP-TDM_n79A

DC_8A_n81A_ULSUP-FDM_n79A

DC_12A-30A_n66A

DC_12A_n66A

DC_30A_n66A

DC_13A-66A_n77A

DC_13A_n77A

DC_66A_n77A

DC_18A-28A_n77A5

DC_18A_n77A

DC_28A_n77A

DC_18A-28A_n78A5

DC_18A_n78A

DC_28A_n78A

DC_18A-28A_n79A5

DC_18A_n79A

DC_28A_n79A

DC_18A-41A_n3A

DC_18A_n3A

DC_41A_n3A

DC_18A-41A_n77A

DC_18A-41C_n77A

DC_18A_n77A

DC_41A_n77A

DC_41C_n77A

DC_18A-41A_n78A

DC_18A-41C_n78A

DC_18A_n78A

DC_41A_n78A

DC_41C_n78A

DC_19A_n1A-n78A5

DC_19A_n1A

DC_19A_n78A

DC_19A_n1A-n79A5

DC_19A_n1A

DC_19A_n79A

DC_19A-21A_n77A5

DC_19A-21A_n77C5

DC_19A_n77A

DC_21A_n77A

DC_19A-21A_n78A5

DC_19A-21A_n78C5

DC_19A_n78A

DC_21A_n78A

DC_19A-21A_n79A5

DC_19A-21A_n79C5

DC_19A_n79A

DC_21A_n79A

DC_19A-42A_n77A

DC_19A-42A_n77C

DC_19A_n77A

DC_19A-42A_n78A

DC_19A-42A_n78C

DC_19A_n78A

DC_19A-42A_n79A

DC_19A-42A_n79C

DC_19A_n79A

DC_19A-42C_n77A

DC_19A-42C_n77C

DC_19A_n77A

DC_19A-42C_n78A

DC_19A-42C_n78C

DC_19A_n78A

DC_19A-42C_n79A

DC_19A-42C_n79C

DC_19A_n79A

DC_19A_n77A-n79A

DC_19A_n77A

DC_19A_n79A

DC_19A_n78A-n79A

DC_19A_n78A

DC_19A_n79A

DC_20A_n8A-n75A6

DC_20A_n8A

DC_20A_n28A-n75A6,11,12

DC_20A_n28A

DC_20A_n28A-n78A5,6,11,12

DC_20A_n28A

DC_20A_n78A

DC_20A_n75A-n78A5

DC_20A_n78A

DC_20A_n76A-n78A5

DC_20A_n78A

DC_20A_SUL_n78A-n82A5

DC_20A_n78A

DC_20A_n82A_ULSUP-TDM_n78A

DC_20A_n82A_ULSUP-FDM_n78A

DC_20A_SUL_n78A-n83A5

DC_20A_n78A

DC_20A_n83A

DC_21A_n1A-n78A5

DC_21A_n1A

DC_21A_n78A

DC_21A_n1A-n79A5

DC_21A_n1A

DC_21A_n79A

DC_21A-28A_n77A

DC_21A-28A_n77C

DC_21A_n77A

DC_28A_n77A

DC_21A-28A_n78A

DC_21A-28A_n78C

DC_21A_n78A

DC_28A_n78A

DC_21A-28A_n79A

DC_21A-28A_n79C

DC_21A_n79A

DC_28A_n79A

DC_21A-42A_n77A10,11

DC_21A-42A_n77C10,11

DC_21A-42C_n77A10,11

DC_21A-42C_n77C10,11

DC_21A_n77A

DC_21A-42A_n78A10,11

DC_21A-42A_n78C10,11

DC_21A-42C_n78A10,11

DC_21A-42C_n78C10,11

DC_21A_n78A

DC_21A-42A_n79A

DC_21A-42A_n79C

DC_21A-42C_n79A

DC_21A-42C_n79C

DC_21A_n79A

DC_21A_n77A-n79A

DC_21A_n77A

DC_21A_n79A

DC_21A_n78A-n79A

DC_21A_n78A

DC_21A_n79A

DC_28A_n7A-n78A

DC_28A_n7A

DC_28A_n78A

DC_28A-42A_n77A10,11

DC_28A-42A_n77C10,11

DC_28A-42C_n77A10,11

DC_28A_n77A

DC_28A-42A_n78A10,11

DC_28A-42A_n78C10,11

DC_28A-42C_n78A10,11

DC_28A_n78A

DC_28A-42A_n79A

DC_28A-42A_n79C

DC_28A-42C_n79A

DC_28A_n79A

DC_28A_SUL_n78A-n83A5

DC_28A_n78A

DC_28A_n83A_ULSUP-TDM_n78A

DC_28A_n83A_ULSUP-FDM_n78A

DC_41A-42A_n77A10,11

DC_41A-42C_n77A10,11

DC_41C-42A_n77A10,11

DC_41C-42C_n77A10,11

DC_41A_n77A

DC_41A-42A_n78A10,11

DC_41A-42C_n78A10,11

DC_41C-42A_n78A10,11

DC_41C-42C_n78A10,11

DC_41A_n78A

DC_41A-42A_n79A

DC_41A-42C_n79A

DC_41C-42A_n79A

DC_41C-42C_n79A

DC_41A_n79A

DC_66A-(n)71AA

DC_66A_n71A

DC_(n)71AA

DC_66A_SUL_n78A-n86A5

DC_66A_n78A

DC_66A_n86A_ULSUP-TDM_n78A

DC_66A_n86A_ULSUP-FDM_n78A

NOTE 1: Uplink EN-DC configurations are the configurations supported by the present release of specifications.

NOTE 2: Only single switched UL is supported.

NOTE 3: Restricted to E-UTRA operation when inter-band carrier aggregation is configured. The downlink operating band for Band 46 is paired with the uplink operating band (external E-UTRA band) of the carrier aggregation configuration that is supporting the configured PCell.

NOTE 4: If a UE is configured with both NR UL and NR SUL carriers in a cell, the switching time between NR UL carrier and NR SUL carrier can be up to 140us and placed in SUL resources.

NOTE 5: Applicable for UE supporting inter-band EN-DC with mandatory simultaneous Rx/Tx capability

NOTE 6: The frequency range in band n28 is restricted for this band combination to 703-733 MHz for the UL and 758-788 MHz for the DL.

NOTE 7: Void.

NOTE 8: Reserved.

NOTE 9: Reserved.

NOTE 10: For UEs not indicating interBandMRDC-WithOverlapDL-Bands-r16, the minimum requirements for intra-band non-contiguous EN-DC apply for the Band 42 and Band n77/n78 combination. For UEs not indicating interBandMRDC-WithOverlapDL-Bands-r16, when UE capability interBandContiguousMRDC is indicated, the minimum requirements for intra-band-contiguous EN-DC also should be met in addtion to intra-band non-contiguous EN-DC.

NOTE 11: For UEs not indicating interBandMRDC-WithOverlapDL-Bands-r16, the minimum requirements for inter-band EN-DC apply when the maximum power spectral density imbalance between downlink carriers contained in overlapping or partially overlapping DL bands is within 6 dB.

NOTE 12: For UEs not indicating interBandMRDC-WithOverlapDL-Bands-r16, the minimum requirements apply for synchronized DL carriers with a maximum receive time difference ≤ 3 usec between overlapping or partially overlapping DL bands contained in different cell groups.

5.5B.4.3 Inter-band EN-DC configurations within FR1 (four bands)

Table 5.5B.4.3-1: Inter-band EN-DC configurations within FR1 (four bands)

EN-DC configuration

Uplink EN-DC configuration (NOTE 1)

DC_1A-3A-5A_n78A2

DC_1A_n78A

DC_3A_n78A

DC_5A_n78A

DC_1A-3A-7A_n28A

DC_1A_n28A

DC_3A_n28A

DC_7A_n28A

DC_1A-3A-7A_n78A2

DC_1A-3C-7A_n78A2

DC_1A_n78A

DC_3A_n78A

DC_7A_n78A

DC_1A-3A-7A-7A_n78A2

DC_1A_n78A

DC_3A_n78A

DC_7A_n78A

DC_1A-3A-8A_n78A2

DC_1A_n78A

DC_3A_n78A

DC_8A_n78A

DC_1A-3A-19A_n77A2

DC_1A-3A-19A_n77C2

DC_1A_n77A

DC_3A_n77A

DC_19A_n77A

DC_1A-3A-19A_n78A2

DC_1A-3A-19A_n78C2

DC_1A_n78A

DC_3A_n78A

DC_19A_n78A

DC_1A-3A-19A_n79A2

DC_1A-3A-19A_n79C2

DC_1A_n79A

DC_3A_n79A

DC_19A_n79A

DC_1A-3A-20A_n28A3,7,8

DC_1A_n28A

DC_3A_n28A

DC_20A_n28A

DC_1A-3A-20A_n78A2

DC_1A_n78A

DC_3A_n78A

DC_20A_n78A

DC_1A-3A-21A_n77A2

DC_1A-3A-21A_n77C2

DC_1A_n77A

DC_3A_n77A

DC_21A_n77A

DC_1A-3A-21A_n78A2

DC_1A-3A-21A_n78C2

DC_1A_n78A

DC_3A_n78A

DC_21A_n78A

DC_1A-3A-21A_n79A2

DC_1A-3A-21A_n79C2

DC_1A_n79A

DC_3A_n79A

DC_21A_n79A

DC_1A-3A-28A_n77A2

DC_1A_n77A

DC_3A_n77A

DC_28A_n77A

DC_1A-3A-28A_n78A2

DC_1A_n78A

DC_3A_n78A

DC_28A_n78A

DC_1A-3A-28A_n79A2

DC_1A_n79A

DC_3A_n79A

DC_28A_n79A

DC_1A-3A_n28A-n78A2

DC_1A_n28A

DC_1A_n78A

DC_3A_n28A

DC_3A_n78A

DC_1A-3A-42A_n77A6,7

DC_1A-3A-42A_n77C6,7

DC_1A-3A-42C_n77A6,7

DC_1A-3A-42C_n77C6,7

DC_1A_n77A

DC_3A_n77A

DC_1A-3A-42A_n78A6,7

DC_1A-3A-42A_n78C6,7

DC_1A-3A-42C_n78A6,7

DC_1A-3A-42C_n78C6,7

DC_1A-3A-42D_n78A6,7

DC_1A_n78A

DC_3A_n78A

DC_1A-3A-42A_n79A

DC_1A-3A-42A_n79C

DC_1A-3A-42C_n79A

DC_1A-3A-42C_n79C

DC_1A-3A-42D_n79A

DC_1A_n79A

DC_3A_n79A

DC_1A-5A-7A_n78A

DC_1A_n78A

DC_5A_n78A

DC_7A_n78A

DC_1A-5A-7A-7A_n78A

DC_1A_n78A

DC_5A_n78A

DC_7A_n78A

DC_1A-7A-20A_n28A3,7,8

DC_1A_n28A

DC_7A_n28A

DC_20A_n28A

DC_1A-7A-20A_n78A2

DC_1A_n78A

DC_7A_n78A

DC_20A_n78A

DC_1A-7A-28A_n78A

DC_1A_n78A

DC_7A_n78A

DC_28A_n78A

DC_1A-7A_n28A-n78A2

DC_1A_n28A

DC_1A_n78A

DC_7A_n28A

DC_7A_n78A

DC_1A-18A-28A_n77A

DC_1A_n77A

DC_18A_n77A

DC_28A_n77A

DC_1A-18A-28A_n78A

DC_1A_n78A

DC_18A_n78A

DC_28A_n78A

DC_1A-18A-28A_n79A2

DC_1A_n79A

DC_18A_n79A

DC_28A_n79A

DC_1A-19A-21A_n77A

DC_1A-19A-21A_n77C

DC_1A_n77A

DC_19A_n77A

DC_21A_n77A

DC_1A-19A-21A_n78A2

DC_1A-19A-21A_n78C2

DC_1A_n78A

DC_19A_n78A

DC_21A_n78A

DC_1A-19A-21A_n79A

DC_1A-19A-21A_n79C

DC_1A_n79A

DC_19A_n79A

DC_21A_n79A

DC_1A-19A-42A_n77A6,7

DC_1A-19A-42A_n77C6,7

DC_1A-19A-42C_n77A6,7

DC_1A-19A-42C_n77C6,7

DC_1A_n77A

DC_19A_n77A

DC_1A-19A-42A_n78A

DC_1A-19A-42A_n78C

DC_1A-19A-42C_n78A

DC_1A-19A-42C_n78C

DC_1A_n78A

DC_19A_n78A

DC_1A-19A-42A_n79A

DC_1A-19A-42A_n79C

DC_1A-19A-42C_n79A

DC_1A-19A-42C_n79C

DC_1A_n79A

DC_19A_n79A

DC_1A-20A_n28A-n78A2,3,7,8

DC_1A_n28A

DC_1A_n78A

DC_20A_n28A

DC_20A_n78A

DC_1A-21A-28A_n77A2

DC_1A_n77A

DC_21A_n77A

DC_28A_n77A

DC_1A-21A-28A_n78A2

DC_1A_n78A

DC_21A_n78A

DC_28A_n78A

DC_1A-21A-28A_n79A2

DC_1A_n79A

DC_21A_n79A

DC_28A_n79A

DC_1A-21A-42A_n77A6,7

DC_1A-21A-42A_n77C6,7

DC_1A-21A-42C_n77A6,7

DC_1A-21A-42C_n77C6,7

DC_1A_n77A

DC_21A_n77A

DC_1A-21A-42A_n78A6,7

DC_1A-21A-42A_n78C6,7

DC_1A-21A-42C_n78A6,7

DC_1A-21A-42C_n78C6,7

DC_1A_n78A

DC_21A_n78A

DC_1A-21A-42A_n79A

DC_1A-21A-42A_n79C

DC_1A-21A-42C_n79A

DC_1A-21A-42C_n79C

DC_1A_n79A

DC_21A_n79A

DC_1A-28A-42A_n77A6,7

DC_1A-28A-42C_n77A6,7

DC_1A_n77A

DC_28A_n77A

DC_1A-28A-42A_n78A

DC_1A-28A-42C_n78A

DC_1A_n78A

DC_28A_n78A

DC_1A-28A-42A_n79A

DC_1A-28A-42C_n79A

DC_1A_n79A

DC_28A_n79A

DC_1A-41A-42A_n77A6,7

DC_1A-41A-42C_n77A6,7

DC_1A-41C-42A_n77A6,7

DC_1A-41C-42C_n77A6,7

DC_1A_n77A

DC_41A_n77A

DC_1A-41A-42A_n78A6,7

DC_1A-41A-42C_n78A6,7

DC_1A-41C-42A_n78A6,7

DC_1A-41C-42C_n78A6,7

DC_1A_n78A

DC_41A_n78A

DC_1A-41A-42A_n79A

DC_1A-41A-42C_n79A

DC_1A-41C-42A_n79A

DC_1A-41C-42C_n79A

DC_1A_n79A

DC_41A_n79A

DC_2A-7A-13A_n66A

DC_2A-7C-13A_n66A

DC_2A_n66A

DC_7A_n66A

DC_13A_n66A

DC_2A-7A-7A-13A_n66A

DC_2A_n66A

DC_7A_n66A

DC_13A_n66A

DC_2A-7A-66A_n66A

DC_2A-7C-66A_n66A

DC_2A_n66A

DC_7A_n66A

DC_66A_n66A4

DC_2A-7A-7A-66A_n66A

DC_2A_n66A

DC_7A_n66A

DC_66A_n66A4

DC_2A-7C-66A_n78A

DC_2A_n78A

DC_7A_n78A

DC_66A_n78A

DC_2A-7A-7A-66A_n78A

DC_2A_n78A

DC_7A_n78A

DC_66A_n78A

DC_2A-13A-66A_n77A

DC_2A_n77A

DC_13A_n77A

DC_66A_n77A

DC_2A-14A-66A_n2A

DC_2A_n2A4

DC_14A_n2A

DC_66A_n2A

DC_2A-14A-66A-66A_n2A

DC_2A_n2A4

DC_14A_n2A

DC_66A_n2A

DC_2A-14A-66A_n66A

DC_2A_n66A

DC_14A_n66A

DC_66A_n66A4

DC_2A-2A-14A-66A_n66A

DC_2A_n66A

DC_14A_n66A

DC_66A_n66A4

DC_2A-66A_n5A-n77A

DC_2A_n5A

DC_2A_n77A

DC_66A_n5A

DC_66A_n77A

DC_2A-66A-(n)71AA

DC_2A_n71A

DC_66A_n71A

DC_(n)71AA

DC_3A-5A-7A_n78A

DC_3A_n78A

DC_5A_n78A

DC_7A_n78A

DC_3A-5A-7A-7A_n78A

DC_3A_n78A

DC_5A_n78A

DC_7A_n78A

DC_3A-7A-20A_n8A

DC_3A_n8A

DC_7A_n8A

DC_20A_n8A

DC_3A-7A-20A_n28A3,7,8

DC_3A_n28A

DC_7A_n28A

DC_20A_n28A

DC_3A-7A-20A_n78A2

DC_3A_n78A

DC_7A_n78A

DC_20A_n78A

DC_3A-7A-28A_n78A2

DC_3A-7C-28A_n78A2

DC_3A_n78A

DC_7A_n78A

DC_28A_n78A

DC_3A-7A_n28A-n78A2

DC_3A_n28A

DC_3A_n78A

DC_7A_n28A

DC_7A_n78A

DC_3A-19A-21A_n77A2

DC_3A-19A-21A_n77C2

DC_3A_n77A

DC_19A_n77A

DC_21A_n77A

DC_3A-19A-21A_n78A2

DC_3A-19A-21A_n78C2

DC_3A_n78A

DC_19A_n78A

DC_21A_n78A

DC_3A-19A-21A_n79A2

DC_3A-19A-21A_n79C2

DC_3A_n79A

DC_19A_n79A

DC_21A_n79A

DC_3A-19A-42A_n77A6,7

DC_3A-19A-42A_n77C6,7

DC_3A-19A-42C_n77A6,7

DC_3A-19A-42C_n77C6,7

DC_3A_n77A

DC_19A_n77A

DC_3A-19A-42A_n78A6,7

DC_3A-19A-42A_n78C6,7

DC_3A-19A-42C_n78A6,7

DC_3A-19A-42C_n78C6,7

DC_3A_n78A

DC_19A_n78A

DC_3A-19A-42A_n79A2

DC_3A-19A-42A_n79C2

DC_3A-19A-42C_n79A2

DC_3A-19A-42C_n79C2

DC_3A_n79A

DC_19A_n79A

DC_3A-20A_n28A-n78A2,3,7,8

DC_3A_n28A

DC_3A_n78A

DC_20A_n28A

DC_20A_n78A

DC_3A-21A-42A_n77A6,7

DC_3A-21A-42A_n77C6,7

DC_3A-21A-42C_n77A6,7

DC_3A-21A-42C_n77C6,7

DC_3A_n77A

DC_21A_n77A

DC_3A-21A-42A_n78A6,7

DC_3A-21A-42A_n78C6,7

DC_3A-21A-42C_n78A6,7

DC_3A-21A-42C_n78C6,7

DC_3A_n78A

DC_21A_n78A

DC_3A-21A-42A_n79A

DC_3A-21A-42A_n79C

DC_3A-21A-42C_n79A

DC_3A-21A-42C_n79C

DC_3A_n79A

DC_21A_n79A

DC_3A-28A-42A_n77A6,7

DC_3A-28A-42C_n77A6,7

DC_3A_n77A

DC_28A_n77A

DC_3A-28A-42A_n78A6,7

DC_3A-28A-42C_n78A6,7

DC_3A_n78A

DC_28A_n78A

DC_3A-28A-42A_n79A

DC_3A-28A-42C_n79A

DC_3A_n79A

DC_28A_n79A

DC_7A-20A_n28A-n78A2,3,7,8

DC_7A_n28A

DC_7A_n78A

DC_20A_n28A

DC_20A_n78A

DC_13A-66A_n2A-n77A

DC_13A_n2A

DC_13A_n77A

DC_66A_n2A

DC_66A_n77A

DC_19A-21A-42A_n77A6,7

DC_19A-21A-42A_n77C6,7

DC_19A-21A-42C_n77A6,7

DC_19A-21A-42C_n77C6,7

DC_19A_n77A

DC_21A_n77A

DC_19A-21A-42A_n78A6,7

DC_19A-21A-42A_n78C6,7

DC_19A-21A-42C_n78A6,7

DC_19A-21A-42C_n78C6,7

DC_19A_n78A

DC_21A_n78A

DC_19A-21A-42A_n79A

DC_19A-21A-42A_n79C

DC_19A-21A-42C_n79A

DC_19A-21A-42C_n79C

DC_19A_n79A

DC_21A_n79A

DC_21A-28A-42A_n77A6,7

DC_21A-28A-42C_n77A6,7

DC_21A_n77A

DC_28A_n77A

DC_21A-28A-42A_n78A6,7

DC_21A-28A-42C_n78A6,7

DC_21A_n78A

DC_28A_n78A

DC_21A-28A-42A_n79A

DC_21A-28A-42C_n79A

DC_21A_n79A

DC_28A_n79A

NOTE 1: Uplink EN-DC configurations are the configurations supported by the present release of specifications.

NOTE 2: Applicable for UE supporting inter-band EN-DC with mandatory simultaneous Rx/Tx capability

NOTE 3: The frequency range in band n28 is restricted for this band combination to 703-733 MHz for the UL and 758-788 MHz for the DL.

NOTE 4: Only single switched UL is supported.

NOTE 5: UL carrier shall be supported in Band 2 or band 66 only. Power imbalance between downlink carriers on Band 7 and Band 38 is assumed to be within 6dB.

NOTE 6: For UEs not indicating interBandMRDC-WithOverlapDL-Bands-r16, the minimum requirements for intra-band non-contiguous EN-DC apply for the Band 42 and Band n77/n78 combination. For UEs not indicating interBandMRDC-WithOverlapDL-Bands-r16, when UE capability interBandContiguousMRDC is indicated, the minimum requirements for intra-band-contiguous EN-DC also should be met in addtion to intra-band non-contiguous EN-DC.

NOTE 7: For UEs not indicating interBandMRDC-WithOverlapDL-Bands-r16, the minimum requirements for inter-band EN-DC apply when the maximum power spectral density imbalance between downlink carriers contained in overlapping or partially overlapping DL bands is within 6 dB.

NOTE 8: For UEs not indicating interBandMRDC-WithOverlapDL-Bands-r16, the minimum requirements apply for synchronized DL carriers with a maximum receive time difference ≤ 3 usec between overlapping or partially overlapping DL bands contained in different cell groups.

5.5B.4.4 Inter-band EN-DC configurations within FR1 (five bands)

Table 5.5B.4.4-1: Inter-band EN-DC configurations within FR1 (five bands)

EN-DC configuration

Uplink EN-DC configuration (NOTE 1)

DC_1A-3A-5A-7A_n78A

DC_1A_n78A

DC_3A_n78A

DC_5A_n78A

DC_7A_n78A

DC_1A-3A-5A-7A-7A_n78A

DC_1A_n78A

DC_3A_n78A

DC_5A_n78A

DC_7A_n78A

DC_1A-3A-5A-41A_n79A

DC_1A_n79A

DC_3A_n79A

DC_5A_n79A

DC_41A_n79A

DC_1A-3A-7A-20A_n28A3,6,7

DC_1A_n28A

DC_3A_n28A

DC_7A_n28A

DC_20A_n28A

DC_1A-3A-7A-20A_n78A2

DC_1A_n78A

DC_3A_n78A

DC_7A_n78A

DC_20A_n78A

DC_1A-3A-7A_n28A-n78A2

DC_1A_n28A

DC_1A_n78A

DC_3A_n28A

DC_3A_n78A

DC_7A_n28A

DC_7A_n78A

DC_1A-3A-7A-28A_n78A

DC_1A_n78A

DC_3A_n78A

DC_7A_n78A

DC_28A_n78A

DC_1A-3A-19A-21A_n77A2

DC_1A-3A-19A-21A_n77C2

DC_1A_n77A

DC_3A_n77A

DC_19A_n77A

DC_21A_n77A

DC_1A-3A-19A-21A_n78A2

DC_1A-3A-19A-21A_n78C2

DC_1A_n78A

DC_3A_n78A

DC_19A_n78A

DC_21A_n78A

DC_1A-3A-19A-21A_n79A2

DC_1A-3A-19A-21A_n79C2

DC_1A_n79A

DC_3A_n79A

DC_19A_n79A

DC_21A_n79A

DC_1A-3A-19A-42A_n77A5,6

DC_1A-3A-19A-42A_n77C5,6

DC_1A-3A-19A-42C_n77A5,6

DC_1A-3A-19A-42C_n77C5,6

DC_1A_n77A

DC_3A_n77A

DC_19A_n77A

DC_1A-3A-19A-42A_n78A5,6

DC_1A-3A-19A-42A_n78C5,6

DC_1A-3A-19A-42C_n78A5,6

DC_1A-3A-19A-42C_n78C5,6

DC_1A_n78A

DC_3A_n78A

DC_19A_n78A

DC_1A-3A-19A-42A_n79A

DC_1A-3A-19A-42A_n79C

DC_1A-3A-19A-42C_n79A

DC_1A-3A-19A-42C_n79C

DC_1A_n79A

DC_3A_n79A

DC_19A_n79A

DC_1A-3A-20A_n28A-n78A2,3,6,7

DC_1A_n28A

DC_1A_n78A

DC_3A_n28A

DC_3A_n78A

DC_20A_n28A

DC_20A_n78A

DC_1A-3A-21A-42A_n77A5,6

DC_1A-3A-21A-42A_n77C5,6

DC_1A-3A-21A-42C_n77A5,6

DC_1A-3A-21A-42C_n77C5,6

DC_1A_n77A

DC_3A_n77A

DC_21A_n77A

DC_1A-3A-21A-42A_n78A5,6

DC_1A-3A-21A-42A_n78C5,6

DC_1A-3A-21A-42C_n78A5,6

DC_1A-3A-21A-42C_n78C5,6

DC_1A_n78A

DC_3A_n78A

DC_21A_n78A

DC_1A-3A-21A-42A_n79A

DC_1A-3A-21A-42A_n79C

DC_1A-3A-21A-42C_n79A

DC_1A-3A-21A-42C_n79C

DC_1A_n79A

DC_3A_n79A

DC_21A_n79A

DC_1A-3A-28A-42A_n77A5,6

DC_1A-3A-28A-42C_n77A5,6

DC_1A_n77A

DC_3A_n77A

DC_28A_n77A

DC_1A-3A-28A-42A_n78A5,6

DC_1A-3A-28A-42C_n78A5,6

DC_1A_n78A

DC_3A_n78A

DC_28A_n78A

DC_1A-3A-28A-42A_n79A

DC_1A-3A-28A-42C_n79A

DC_1A_n79A

DC_3A_n79A

DC_28A_n79A

DC_1A-7A-20A_n28A-n78A2,3,6,7

DC_1A_n28A

DC_1A_n78A

DC_7A_n28A

DC_7A_n78A

DC_20A_n28A

DC_20A_n78A

DC_1A-19A-21A-42A_n77A5,6

DC_1A-19A-21A-42A_n77C5,6

DC_1A-19A-21A-42C_n77A5,6

DC_1A-19A-21A-42C_n77C5,6

DC_1A_n77A

DC_19A_n77A

DC_21A_n77A

DC_1A-19A-21A-42A_n78A5,6

DC_1A-19A-21A-42A_n78C5,6

DC_1A-19A-21A-42C_n78A5,6

DC_1A-19A-21A-42C_n78C5,6

DC_1A_n78A

DC_19A_n78A

DC_21A_n78A

DC_1A-19A-21A-42A_n79A

DC_1A-19A-21A-42A_n79C

DC_1A-19A-21A-42C_n79A

DC_1A-19A-21A-42C_n79C

DC_1A_n79A

DC_19A_n79A

DC_21A_n79A

DC_1A-21A-28A-42A_n77A

DC_1A-21A-28A-42C_n77A

DC_1A_n77A

DC_21A_n77A

DC_28A_n77A

DC_1A-21A-28A-42A_n78A

DC_1A-21A-28A-42C_n78A

DC_1A_n78A

DC_21A_n78A

DC_28A_n78A

DC_1A-21A-28A-42A_n79A

DC_1A-21A-28A-42C_n79A

DC_1A_n79A

DC_21A_n79A

DC_28A_n79A

DC_3A-7A-20A_n28A-n78A2,3,6,7

DC_3A_n28A

DC_3A_n78A

DC_7A_n28A

DC_7A_n78A

DC_20A_n28A

DC_20A_n78A

DC_3A-19A-21A-42A_n78A5,6

DC_3A-19A-21A-42C_n78A5,6

DC_3A_n78A

DC_19A_n78A

DC_21A_n78A

DC_3A-19A-21A-42A_n79A5,6

DC_3A-19A-21A-42C_n79A5,6

DC_3A_n79A

DC_19A_n79A

DC_21A_n79A

NOTE 1: Uplink EN-DC configurations are the configurations supported by the present release of specifications.

NOTE 2: Applicable for UE supporting inter-band EN-DC with mandatory simultaneous Rx/Tx capability

NOTE 3: The frequency range in band n28 is restricted for this band combination to 703-733 MHz for the UL and 758-788 MHz for the DL

NOTE 4: Reserved.

NOTE 5: For UEs not indicating interBandMRDC-WithOverlapDL-Bands-r16, the minimum requirements for intra-band non-contiguous EN-DC apply for the Band 42 and Band n77/n78 combination. For UEs not indicating interBandMRDC-WithOverlapDL-Bands-r16, when UE capability interBandContiguousMRDC is indicated, the minimum requirements for intra-band-contiguous EN-DC also should be met in addtion to intra-band non-contiguous EN-DC.

NOTE 6: For UEs not indicating interBandMRDC-WithOverlapDL-Bands-r16, the minimum requirements for inter-band EN-DC apply when the maximum power spectral density imbalance between downlink carriers contained in overlapping or partially overlapping DL bands is within 6 dB.

NOTE 7: For UEs not indicating interBandMRDC-WithOverlapDL-Bands-r16, the minimum requirements apply for synchronized DL carriers with a maximum receive time difference ≤ 3 usec between overlapping or partially overlapping DL bands contained in different cell groups.

5.5B.4.5 Inter-band EN-DC configurations within FR1 (six bands)

Table 5.5B.4.5-1: Inter-band EN-DC configurations within FR1 (six bands)

EN-DC configuration

Uplink EN-DC configuration (NOTE 1)

DC_1A-3A-7A-20A_n28A-n78A2,3,5,6

DC_1A_n28A

DC_1A_n78A

DC_3A_n28A

DC_3A_n78A

DC_7A_n28A

DC_7A_n78A

DC_20A_n28A

DC_20A_n78A

NOTE 1: Uplink EN-DC configurations are the configurations supported by the present release of specifications.

NOTE 2: Applicable for UE supporting inter-band EN-DC with mandatory simultaneous Rx/Tx capability.

NOTE 3: The frequency range in band n28 is restricted for this band combination to 703-733 MHz for the UL and 758-788 MHz for the DL.

NOTE 4: Reserved

NOTE 5: For UEs not indicating interBandMRDC-WithOverlapDL-Bands-r16, the minimum requirements for inter-band EN-DC apply when the maximum power spectral density imbalance between downlink carriers contained in overlapping or partially overlapping DL bands is within 6 dB.

NOTE 6: For UEs not indicating interBandMRDC-WithOverlapDL-Bands-r16, the minimum requirements apply for synchronized DL carriers with a maximum receive time difference ≤ 3 usec between overlapping or partially overlapping DL bands contained in different cell groups.

5.5B.4a Inter-band NE-DC within FR1

5.5B.4a.1 Inter-band NE-DC configurations within FR1 (two bands)

Table 5.5B.4a.1-1: Inter-band NE-DC configurations within FR1 (two bands)

NE-DC configuration

Uplink NE-DC configuration (NOTE 1)

Single UL allowed

DC_n1A_28A

DC_n1A_28A

No

DC_n28A_3A

DC_n28A_3C

DC_n28A_3A

No

DC_n28A_39A

DC_n28A_39C

DC_n28A_39A

No

NOTE 1: Uplink EN-DC configurations are the configurations supported by the present release of specifications.

5.5B.5 Inter-band EN-DC including FR2

Supported channel bandwidths for E-UTRA operating bands and CA configurations are defined in TS 36.521-1 [10] and for NR operating bands and CA configurations in TS 38.521-1 [8], TS 38.521-2 [9] and present document.

5.5B.5.1 Inter-band EN-DC configurations including FR2 (two bands)

Table 5.5B.5.1-1: Inter-band EN-DC configurations including FR2 (two bands)

EN-DC configuration

Uplink EN-DC configuration (NOTE 1)

DC_1A_n257A

DC_1A_n257A

DC_2A_n257A

DC_2C_n257A

DC_2A_n257A

DC_2A_n257(2A)

DC_2A_n257A

DC_2A-2A_n257A

DC_2A_n257A

DC_2A_n260A

DC_2A_n260G

DC_2A_n260H

DC_2A_n260I

DC_2A_n260J

DC_2A_n260K

DC_2A_n260L

DC_2A_n260M

DC_2C_n260A

DC_2A_n260A

DC_2A_n260G

DC_2A_n260H

DC_2A_n261A

DC_2A_n261G

DC_2A_n261H

DC_2A_n261I

DC_2A_n261J

DC_2A_n261M

DC_2A_n261G

DC_2A_n261H

DC_2A_n261I

DC_2A_n261(2A)

DC_2A_n261(3A)

DC_2A_n261(4A)

DC_2A_n261A

DC_2A_n261(2G)

DC_2A_n261(2H)

DC_2A_n261(2I)

DC_2A_n261A

DC_2A_n261G

DC_2A_n261H

DC_2A_n261I

DC_2A_n261(A-G)

DC_2A_n261(A-2G)

DC_2A_n261(A-H)

DC_2A_n261(A-I)

DC_2A_n261(A-K)

DC_2A_n261(G-H)

DC_2A_n261(G-I)

DC_2A_n261(G-J)

DC_2A_n261(H-I)

DC_2A_n261(2A-G)

DC_2A_n261(2A-I)

DC_2A_n261(3A-G)

DC_2A_n261A

DC_2A_n261G

DC_2A_n261H

DC_2A_n261I

DC_2A_n261(A-G-H)

DC_2A_n261(A-G-I)

DC_2A_n261A

DC_2A_n261G

DC_2A_n261H

DC_2A_n261I

DC_3A_n257G

DC_3A_n257H

DC_3A_n257I

DC_3A_n257G

DC_3A_n257H

DC_3A_n257I

DC_5A_n260A

DC_5A_n260G

DC_5A_n260H

DC_5A_n260I

DC_5A_n260J

DC_5A_n260K

DC_5A_n260L

DC_5A_n260M

DC_5A_n260O

DC_5A_n260P

DC_5A_n260Q

DC_5B_n260A

DC_5A_n260A

DC_5A_n260G

DC_5A_n260H

DC_5A_n260O

DC_5A_n260P

DC_5A_n260Q

DC_5A_n261A

DC_5A_n261G

DC_5A_n261H

DC_5A_n261I

DC_5A_n261J

DC_5A_n261M

DC_5A_n261A

DC_5A_n261G

DC_5A_n261H

DC_5A_n261I

DC_5A_n261(2A)

DC_5A_n261(3A)

DC_5A_n261(4A)

DC_5A_n261A

DC_5A_n261G

DC_5A_n261H

DC_5A_n261I

DC_8A_n257A

DC_8A_n257D

DC_8A_n257E

DC_8A_n257F

DC_8A_n257G

DC_8A_n257H

DC_8A_n257I

DC_8A_n257J

DC_8A_n257K

DC_8A_n257L

DC_8A_n257M

DC_8A_n257A

DC_13A_n257A

DC_13A_n257A

DC_13A_n260A

DC_13A_n260G

DC_13A_n260H

DC_13A_n260I

DC_13A_n260J

DC_13A_n260M

DC_13A_n260A

DC_13A_n260G

DC_13A_n260H

DC_13A_n260O

DC_14A_n260A

DC_14A_n260G

DC_14A_n260H

DC_14A_n260I

DC_14A_n260A

DC_14A_n260G

DC_14A_n260H

DC_14A_n260I

DC_18A_n257A

DC_18A_n257A

DC_19A_n257A

DC_19A_n257D

DC_19A_n257E

DC_19A_n257F

DC_19A_n257G

DC_19A_n257H

DC_19A_n257I

DC_19A_n257A

DC_19A_n257G

DC_19A_n257H

DC_19A_n257I

DC_20A_n257A

DC_20A_n257A

DC_21A_n257A

DC_21A_n257G

DC_21A_n257A

DC_21A_n257G

DC_26A_n257A

DC_26A_n257A

DC_66A_n260A

DC_66A_n260D

DC_66A_n260E

DC_66A_n260F

DC_66A_n260G

DC_66A_n260H

DC_66A_n260I

DC_66A_n260J

DC_66A_n260K

DC_66A_n260L

DC_66A_n260M

DC_66A_n260O

DC_66A_n260P

DC_66A_n260Q

DC_66A_n260A

DC_66A_n260G

DC_66A_n260H

DC_66A_n260O

DC_66A_n260P

DC_66A_n260Q

DC_66A-66A_n260A

DC_66A-66A_n260G

DC_66A-66A_n260H

DC_66A-66A_n260I

DC_66A-66A_n260J

DC_66A-66A_n260K

DC_66A-66A_n260L

DC_66A-66A_n260M

DC_66A_n260A

DC_66A_n260G

DC_66A_n260H

DC_66A_n260I

DC_66A_n261G

DC_66A_n261H

DC_66A_n261I

DC_66A_n261J

DC_66A_n261K

DC_66A_n261L

DC_66A_n261M

DC_66A_n261A

DC_66A_n261G

DC_66A_n261H

DC_66A_n261I

DC_66A_n261(2G)

DC_66A_n261(2H)

DC_66A_n261(2I)

DC_66A_n261A

DC_66A_n261G

DC_66A_n261H

DC_66A_n261I

DC_66A_n261(A-K)

DC_66A_n261(A-2G)

DC_66A_n261(A-2H)

DC_66A_n261(2A-G)

DC_66A_n261(2A-H)

DC_66A_n261(2A-I)

DC_66A_n261(3A-G)

DC_66A_n261A

DC_66A_n261G

DC_66A_n261H

DC_66A_n261I

DC_66A_n261(A-G-H)

DC_66A_n261(A-G-I)

DC_66A_n261A

DC_66A_n261G

DC_66A_n261H

DC_66A_n261I

DC_66A-66A_n260G

DC_66A-66A_n260H

DC_66A-66A_n260I

DC_66A-66A_n260J

DC_66A-66A_n260K

DC_66A-66A_n260L

DC_66A-66A_n260M

DC_66A_n261A

DC_66A_n261G

DC_66A_n261H

DC_66A_n261I

NOTE 1: Uplink EN-DC configurations are the configurations supported by the present release of specifications.

NOTE 2: Applicable for UE supporting inter-band EN-DC with mandatory simultaneous Rx/Tx capability for all of the above combinations

5.5B.5.2 Inter-band EN-DC configurations including FR2 (three bands)

Table 5.5B.5.2-1: Inter-band EN-DC configurations including FR2 (three bands)

EN-DC configuration

Uplink EN-DC configuration (NOTE 1)

DC_1A-3A_n257A2

DC_1A-3A_n257G

DC_1A-3A_n257H

DC_1A-3A_n257I

DC_1A_n257A

DC_3A_n257A

DC_3A_n257G

DC_3A_n257H

DC_3A_n257I

DC_1A-19A_n257A2

DC_1A-19A_n257E2

DC_1A-19A_n257F2

DC_1A-19A_n257G

DC_1A-19A_n257H

DC_1A-19A_n257I

DC_1A_n257A

DC_1A_n257G

DC_1A_n257H

DC_1A_n257I

DC_19A_n257A

DC_1A-21A_n257A2

DC_1A-21A_n257D2

DC_1A-21A_n257E2

DC_1A-21A_n257F2

DC_1A-21A_n257G

DC_1A-21A_n257H

DC_1A-21A_n257I

DC_1A_n257A

DC_1A_n257G

DC_1A_n257H

DC_1A_n257I

DC_21A_n257A

DC_21A_n257G

DC_21A_n257H

DC_21A_n257I

DC_1A-42A_n257A

DC_1A-42A_n257G

DC_1A-42A_n257H

DC_1A-42A_n257I

DC_1A-42C_n257A

DC_1A-42D_n257A

DC_1A-42D_n257G

DC_1A-42D_n257H

DC_1A-42D_n257I

DC_1A-42E_n257A

DC_1A-42E_n257G

DC_1A-42E_n257H

DC_1A-42E_n257I

DC_1A_n257A

DC_1A_n257G

DC_1A_n257H

DC_1A_n257I

DC_42A_n257A

DC_2A-5A_n257A2

DC_2A_n257A

DC_5A_n257A

DC_2A-5A_n260A

DC_2A-5A_n260G

DC_2A-5A_n260H

DC_2A-5A_n260I

DC_2A-5A_n260J

DC_2A-5A_n260K

DC_2A-5A_n260L

DC_2A-5A_n260M

DC_2A_n260A

DC_5A_n260A

DC_2A-5A_n261A

DC_2A-5A_n261G

DC_2A-5A_n261H

DC_2A-5A_n261I

DC_2A-5A_n261J

DC_2A-5A_n261K

DC_2A-5A_n261L

DC_2A-5A_n261M

DC_2A_n261A

DC_5A_n261A

DC_2A_n261G

DC_5A_n261G

DC_2A_n261H

DC_5A_n261H

DC_2A_n261I

DC_5A_n261I

DC_2A-13A_n257A2

DC_2A_n257A

DC_13A_n257A

DC_2A-13A_n260A2

DC_2A_n260A

DC_13A_n260A

DC_2A-13A_n261A

DC_2A-13A_n261G

DC_2A-13A_n261H

DC_2A-13A_n261I

DC_2A-13A_n261J

DC_2A-13A_n261K

DC_2A-13A_n261L

DC_2A-13A_n261M

DC_2A_n261A

DC_13A_n261A

DC_2A_n261G

DC_13A_n261G

DC_2A_n261H

DC_13A_n261H

DC_2A-13A_n261(2A)

DC_2A-13A_n261(2G)

DC_2A-13A_n261(2H)

DC_2A-13A_n261(3A)

DC_2A-13A_n261(4A)

DC_2A_n261A

DC_13A_n261A

DC_2A_n261G

DC_13A_n261G

DC_2A_n261H

DC_13A_n261H

DC_2A-13A_n261(A-G)

DC_2A-13A_n261(A-2G)

DC_2A-13A_n261(A-H)

DC_2A-13A_n261(A-I)

DC_2A-13A_n261(A-J)

DC_2A-13A_n261(A-K)

DC_2A-13A_n261(G-H)

DC_2A-13A_n261(G-I)

DC_2A-13A_n261(G-J)

DC_2A-13A_n261(H-I)

DC_2A-13A_n261(2A-G)

DC_2A-13A_n261(2A-H)

DC_2A-13A_n261(2A-I)

DC_2A-13A_n261(3A-G)

DC_2A_n261A

DC_13A_n261A

DC_2A_n261G

DC_13A_n261G

DC_2A_n261H

DC_13A_n261H

DC_2A-13A_n261(A-G-H)

DC_2A-13A_n261(A-G-I)

DC_2A_n261A

DC_13A_n261A

DC_2A_n261G

DC_13A_n261G

DC_2A_n261H

DC_13A_n261H

DC_2A-14A_n260A

DC_2A-14A_n260G

DC_2A-14A_n260H

DC_2A-14A_n260I

DC_2A_n260A

DC_2A_n260G

DC_2A_n260H

DC_2A_n260I

DC_14A_n260A

DC_14A_n260G

DC_14A_n260H

DC_14A_n260I

DC_2A-2A-14A_n260A

DC_2A-2A-14A_n260G

DC_2A-2A-14A_n260H

DC_2A-2A-14A_n260I

DC_2A_n260A

DC_2A_n260G

DC_2A_n260H

DC_2A_n260I

DC_14A_n260A

DC_14A_n260G

DC_14A_n260H

DC_14A_n260I

DC_2A-30A_n260A

DC_2A-30A_n260G

DC_2A-30A_n260H

DC_2A-30A_n260I

DC_2A-30A_n260J

DC_2A-30A_n260K

DC_2A-30A_n260L

DC_2A-30A_n260M

DC_2A_n260A

DC_30A_n260A

DC_2A-66A_n257A2

DC_2A_n257A

DC_66A_n257A

DC_2A-66A_n260A

DC_2A-66A_n260G

DC_2A-66A_n260H

DC_2A-66A_n260I

DC_2A-66A_n260J

DC_2A-66A_n260K

DC_2A-66A_n260L

DC_2A-66A_n260M

DC_2A_n260A

DC_66A_n260A

DC_2A_n260G

DC_66A_n260G

DC_2A_n260H

DC_66A_n260H

DC_2A_n260I

DC_66A_n260I

DC_3A-5A_n257A2

DC_3A_n257A

DC_5A_n257A

DC_3A-7A_n257A2

DC_3A_n257A

DC_7A_n257A

DC_3A-7A-7A_n257A2

DC_3A_n257A

DC_7A_n257A

DC_3A-19A_n257A2

DC_3A-19A_n257D2

DC_3A-19A_n257E2

DC_3A-19A_n257F2

DC_3A-19A_n257G

DC_3A-19A_n257H

DC_3A-19A_n257I

DC_3A_n257A

DC_3A_n257D

DC_3A_n257G

DC_3A_n257H

DC_3A_n257I

DC_19A_n257A

DC_19A_n257D

DC_3A-21A_n257A2

DC_3A-21A_n257D2

DC_3A-21A_n257E2

DC_3A-21A_n257F2

DC_3A-21A_n257G

DC_3A-21A_n257H

DC_3A-21A_n257I

DC_3A_n257A

DC_3A_n257D

DC_3A_n257G

DC_3A_n257H

DC_3A_n257I

DC_21A_n257A

DC_21A_n257D

DC_3A-28A_n257A2

DC_3A-28A_n257D2

DC_3A-28A_n257E2

DC_3A-28A_n257F2

DC_3A_n257A

DC_28A_n257A

DC_3A-41A_n257A

DC_3A_n257A

DC_41A_n257A

DC_3A-42A_n257A2

DC_3A-42A_n257D2

DC_3A-42A_n257E2

DC_3A-42A_n257F2

DC_3A-42A_n257G

DC_3A-42A_n257H

DC_3A-42A_n257I

DC_3A-42C_n257A2

DC_3A-42C_n257D2

DC_3A-42C_n257E2

DC_3A-42C_n257F2

DC_3A-42C_n257G

DC_3A-42C_n257H

DC_3A-42C_n257I

DC_3A-42D_n257A2

DC_3A-42D_n257G

DC_3A-42D_n257H

DC_3A-42D_n257I

DC_3A-42E_n257A2

DC_3A-42E_n257G

DC_3A-42E_n257H

DC_3A-42E_n257I

DC_3A_n257A

DC_3A_n257D

DC_3A_n257G

DC_3A_n257H

DC_3A_n257I

DC_42A_n257A

DC_42A_n257D

DC_5A-7A_n257A2

DC_5A_n257A

DC_7A_n257A

DC_5A-7A-7A_n257A

DC_5A_n257A

DC_7A_n257A

DC_5A-30A_n260A

DC_5A-30A_n260G

DC_5A-30A_n260H

DC_5A-30A_n260I

DC_5A-30A_n260J

DC_5A-30A_n260K

DC_5A-30A_n260L

DC_5A-30A_n260M

DC_5A_n260A

DC_30A_n260A

DC_5A-66A_n257A

DC_5A_n257A

DC_66A_n257A

DC_5A-66A_n260A

DC_5A-66A_n260G

DC_5A-66A_n260H

DC_5A-66A_n260I

DC_5A-66A_n260J

DC_5A-66A_n260K

DC_5A-66A_n260L

DC_5A-66A_n260M

DC_5A_n260A

DC_66A_n260A

DC_12A-30A_n260A

DC_12A-30A_n260G

DC_12A-30A_n260H

DC_12A-30A_n260I

DC_12A-30A_n260J

DC_12A-30A_n260K

DC_12A-30A_n260L

DC_12A-30A_n260M

DC_12A_n260A

DC_30A_n260A

DC_12A-66A_n260A

DC_12A-66A_n260G

DC_12A-66A_n260H

DC_12A-66A_n260I

DC_12A-66A_n260J

DC_12A-66A_n260K

DC_12A-66A_n260L

DC_12A-66A_n260M

DC_12A_n260A

DC_66A_n260A

DC_13A-66A_n257A2

DC_13A_n257A

DC_66A_n257A

DC_13A-66A_n260A2

DC_13A_n260A

DC_66A_n260A

DC_14A-30A_n260A

DC_14A-30A_n260G

DC_14A-30A_n260H

DC_14A-30A_n260I

DC_14A_n260A

DC_14A_n260G

DC_14A_n260H

DC_14A_n260I

DC_30A_n260A

DC_30A_n260G

DC_30A_n260H

DC_30A_n260I

DC_14A-66A_n260A

DC_14A-66A_n260G

DC_14A-66A_n260H

DC_14A-66A_n260I

DC_14A_n260A

DC_14A_n260G

DC_14A_n260H

DC_14A_n260I

DC_66A_n260A

DC_66A_n260G

DC_66A_n260H

DC_66A_n260I

DC_14A-66A-66A_n260A

DC_14A-66A-66A_n260G

DC_14A-66A-66A_n260H

DC_14A-66A-66A_n260I

DC_14A_n260A

DC_14A_n260G

DC_14A_n260H

DC_14A_n260I

DC_66A_n260A

DC_66A_n260G

DC_66A_n260H

DC_66A_n260I

DC_18A-28A_n257A2

DC_18A_n257A

DC_28A_n257A

DC_19A-21A_n257A2

DC_19A-21A_n257D2

DC_19A-21A_n257E2

DC_19A-21A_n257F2

DC_19A-21A_n257G

DC_19A-21A_n257H

DC_19A-21A_n257I

DC_19A_n257A

DC_19A_n257D

DC_21A_n257A

DC_21A_n257D

DC_21A_n257G

DC_19A-42A_n257A2

DC_19A-42A_n257D2

DC_19A-42A_n257E2

DC_19A-42A_n257F2

DC_19A-42A_n257G2

DC_19A-42A_n257H2

DC_19A-42A_n257I2

DC_19A-42C_n257A2

DC_19A-42C_n257G2

DC_19A-42C_n257H2

DC_19A-42C_n257I2

DC_19A_n257A

DC_19A_n257D

DC_19A_n257G

DC_19A_n257H

DC_19A_n257I

DC_42A_n257A

DC_42A_n257D

DC_42A_n257G

DC_42A_n257H

DC_42A_n257I

DC_21A-28A_n257A2

DC_21A-28A_n257D2

DC_21A_n257A

DC_28A_n257A

DC_21A-42A_n257A2

DC_21A-42A_n257D2

DC_21A-42A_n257E2

DC_21A-42A_n257F2

DC_21A-42A_n257G

DC_21A-42A_n257H

DC_21A-42A_n257I

DC_21A-42C_n257A2

DC_21A-42C_n257G

DC_21A-42C_n257H

DC_21A-42C_n257I

DC_21A_n257A

DC_21A_n257D

DC_21A_n257G

DC_21A_n257H

DC_21A_n257I

DC_42A_n257A

DC_42A_n257D

DC_28A-42C_n257A2

DC_28A-42A_n257A2

DC_28A_n257A

DC_42A_n257A

DC_30A-66A_n260A

DC_30A-66A_n260G

DC_30A-66A_n260H

DC_30A-66A_n260I

DC_30A-66A_n260J

DC_30A-66A_n260K

DC_30A-66A_n260L

DC_30A-66A_n260M

DC_30A_n260A

DC_66A_n260A

DC_41A-42A_n257A

DC_41A_n257A

DC_42A_n257A

NOTE 1: Uplink EN-DC configurations are the configurations supported by the present release of specifications.

NOTE 2: Applicable for UE supporting inter-band EN-DC with mandatory simultaneous Rx/Tx capability for all of the above combinations.

5.5B.5.3 Inter-band EN-DC configurations including FR2 (four bands)

Table 5.5B.5.3-1: Inter-band EN-DC configurations including FR2 (four bands)

EN-DC configuration

Uplink EN-DC configuration (NOTE 1)

DC_1A-3A-19A_n257A2

DC_1A-3A-19A_n257G

DC_1A-3A-19A_n257H

DC_1A-3A-19A_n257I

DC_1A_n257A

DC_3A_n257A

DC_3A_n257G

DC_3A_n257H

DC_3A_n257I

DC_19A_n257A

DC_1A-3A-21A_n257A2

DC_1A-3A-21A_n257G

DC_1A-3A-21A_n257H

DC_1A-3A-21A_n257I

DC_1A_n257A

DC_3A_n257A

DC_3A_n257G

DC_3A_n257H

DC_3A_n257I

DC_21A_n257A

DC_1A-3A-42A_n257A

DC_1A-3A-42A_n257G

DC_1A-3A-42A_n257H

DC_1A-3A-42A_n257I

DC_1A-3A-42C_n257A

DC_1A-3A-42C_n257G

DC_1A-3A-42C_n257H

DC_1A-3A-42C_n257I

DC_1A-3A-42D_n257G

DC_1A-3A-42D_n257H

DC_1A-3A-42D_n257I

DC_1A_n257A

DC_1A_n257G

DC_1A_n257H

DC_1A_n257I

DC_3A_n257A

DC_3A_n257G

DC_3A_n257H

DC_3A_n257I

DC_1A-19A-21A_n257G

DC_1A-19A-21A_n257H

DC_1A-19A-21A_n257I

DC_1A_n257G

DC_1A_n257H

DC_1A_n257I

DC_21A_n257G

DC_21A_n257H

DC_21A_n257I

DC_1A-19A-42A_n257A

DC_1A-19A-42A_n257G

DC_1A-19A-42A_n257H

DC_1A-19A-42A_n257I

DC_1A-19A-42C_n257A

DC_1A-19A-42C_n257D

DC_1A-19A-42C_n257E

DC_1A-19A-42C_n257F

DC_1A-19A-42C_n257G

DC_1A-19A-42C_n257H

DC_1A-19A-42C_n257I

DC_1A_n257A

DC_1A_n257G

DC_1A_n257H

DC_1A_n257I

DC_19A_n257A

DC_42A_n257A

DC_1A-21A-28A_n257A2

DC_1A_n257A

DC_21A_n257A

DC_28A_n257A

DC_1A-21A-42A_n257A

DC_1A-21A-42A_n257G

DC_1A-21A-42A_n257H

DC_1A-21A-42A_n257I

DC_1A-21A-42C_n257A

DC_1A-21A-42C_n257D

DC_1A-21A-42C_n257E

DC_1A-21A-42C_n257F

DC_1A-21A-42C_n257G

DC_1A-21A-42C_n257H

DC_1A-21A-42C_n257I

DC_1A_n257A

DC_1A_n257G

DC_1A_n257H

DC_1A_n257I

DC_21A_n257A

DC_21A_n257G

DC_21A_n257H

DC_21A_n257I

DC_42A_n257A

DC_42A_n257D

DC_1A-28A-42A_n257A

DC_1A-28A-42C_n257A

DC_1A_n257A

DC_28A_n257A

DC_42A_n257A

DC_1A-41A-42A_n257A

DC_1A-41A-42C_n257A

DC_1A-41C-42A_n257A

DC_1A-41C-42C_n257A

DC_1A_n257A

DC_41A_n257A

DC_42A_n257A

DC_2A-14A-30A_n260A

DC_2A-14A-30A_n260G

DC_2A-14A-30A_n260H

DC_2A-14A-30A_n260I

DC_2A_n260A

DC_2A_n260G

DC_2A_n260H

DC_2A_n260I

DC_14A_n260A

DC_14A_n260G

DC_14A_n260H

DC_14A_n260I

DC_30A_n260A

DC_30A_n260G

DC_30A_n260H

DC_30A_n260I

DC_2A-14A-66A_n260A

DC_2A-14A-66A_n260G

DC_2A-14A-66A_n260H

DC_2A-14A-66A_n260I

DC_2A_n260A

DC_2A_n260G

DC_2A_n260H

DC_2A_n260I

DC_14A_n260A

DC_14A_n260G

DC_14A_n260H

DC_14A_n260I

DC_66A_n260A

DC_66A_n260G

DC_66A_n260H

DC_66A_n260I

DC_2A-14A-66A-66A_n260A

DC_2A-14A-66A-66A_n260G

DC_2A-14A-66A-66A_n260H

DC_2A-14A-66A-66A_n260I

DC_2A_n260A

DC_2A_n260G

DC_2A_n260H

DC_2A_n260I

DC_14A_n260A

DC_14A_n260G

DC_14A_n260H

DC_14A_n260I

DC_66A_n260A

DC_66A_n260G

DC_66A_n260H

DC_66A_n260I

DC_3A-5A-7A_n257A2

DC_3A_n257A

DC_5A_n257A

DC_7A_n257A

DC_3A-5A-7A-7A_n257A2

DC_3A_n257A

DC_5A_n257A

DC_7A_n257A

DC_3A-19A-21A_n257A2

DC_3A_n257A

DC_19A_n257A

DC_21A_n257A

DC_3A-19A-42A_n257A

DC_3A-19A-42A_n257G

DC_3A-19A-42A_n257H

DC_3A-19A-42A_n257I

DC_3A-19A-42C_n257A

DC_3A-19A-42C_n257D

DC_3A-19A-42C_n257E

DC_3A-19A-42C_n257F

DC_3A-19A-42C_n257G

DC_3A-19A-42C_n257H

DC_3A-19A-42C_n257I

DC_3A_n257A

DC_3A_n257D

DC_3A_n257G

DC_3A_n257H

DC_3A_n257I

DC_19A_n257A

DC_19A_n257D

DC_19A_n257G

DC_19A_n257H

DC_19A_n257I

DC_42A_n257A

DC_42A_n257D

DC_42A_n257G

DC_42A_n257H

DC_42A_n257I

DC_3A-21A-42A_n257A

DC_3A-21A-42A_n257G

DC_3A-21A-42A_n257H

DC_3A-21A-42A_n257I

DC_3A-21A-42C_n257A

DC_3A-21A-42C_n257D

DC_3A-21A-42C_n257E

DC_3A-21A-42C_n257F

DC_3A-21A-42C_n257G

DC_3A-21A-42C_n257H

DC_3A-21A-42C_n257I

DC_3A_n257A

DC_3A_n257D

DC_3A_n257G

DC_3A_n257H

DC_3A_n257I

DC_21A_n257A

DC_21A_n257D

DC_21A_n257G

DC_21A_n257H

DC_21A_n257I

DC_42A_n257A

DC_42A_n257D

DC_42A_n257G

DC_42A_n257H

DC_42A_n257I

DC_3A-28A-42A_n257A

DC_3A-28A-42C_n257A

DC_3A_n257A

DC_28A_n257A

DC_42A_n257A

DC_14A-30A-66A_n260A

DC_14A-30A-66A_n260G

DC_14A-30A-66A_n260H

DC_14A-30A-66A_n260I

DC_14A_n260A

DC_14A_n260G

DC_14A_n260H

DC_14A_n260I

DC_30A_n260A

DC_30A_n260G

DC_30A_n260H

DC_30A_n260I

DC_66A_n260A

DC_66A_n260G

DC_66A_n260H

DC_66A_n260I

DC_14A-30A-66A-66A_n260A

DC_14A-30A-66A-66A_n260G

DC_14A-30A-66A-66A_n260H

DC_14A-30A-66A-66A_n260I

DC_14A_n260A

DC_14A_n260G

DC_14A_n260H

DC_14A_n260I

DC_30A_n260A

DC_30A_n260G

DC_30A_n260H

DC_30A_n260I

DC_66A_n260A

DC_66A_n260G

DC_66A_n260H

DC_66A_n260I

DC_19A-21A-42A_n257A2

DC_19A-21A-42A_n257G2

DC_19A-21A-42A_n257H2

DC_19A-21A-42A_n257I2

DC_19A-21A-42C_n257A2

DC_19A-21A-42C_n257D2

DC_19A-21A-42C_n257E2

DC_19A-21A-42C_n257F2

DC_19A-21A-42C_n257G2

DC_19A-21A-42C_n257H2

DC_19A-21A-42C_n257I2

DC_19A_n257A

DC_19A_n257D

DC_19A_n257G

DC_19A_n257H

DC_19A_n257I

DC_21A_n257A

DC_21A_n257D

DC_21A_n257G

DC_21A_n257H

DC_21A_n257I

DC_42A_n257A

DC_42A_n257D

DC_42A_n257G

DC_42A_n257H

DC_42A_n257I

DC_21A-28A-42A_n257A2

DC_21A-28A-42C_n257A2

DC_21A_n257A

DC_28A_n257A

DC_42A_n257A

NOTE 1: Uplink EN-DC configurations are the configurations supported by the present release of specifications.

NOTE 2: Applicable for UE supporting inter-band EN-DC with mandatory simultaneous Rx/Tx capability for all of the above combinations.

5.5B.5.4 Inter-band EN-DC configurations including FR2 (five bands)

Table 5.5B.5.4-1: Inter-band EN-DC configurations including FR2 (five bands)

EN-DC configuration

Uplink EN-DC configuration (NOTE 1)

DC_1A-3A-19A-42A_n257A

DC_1A-3A-19A-42A_n257D

DC_1A-3A-19A-42A_n257E

DC_1A-3A-19A-42A_n257F

DC_1A-3A-19A-42A_n257G

DC_1A-3A-19A-42A_n257H

DC_1A-3A-19A-42A_n257I

DC_1A-3A-19A-42C_n257A

DC_1A-3A-19A-42C_n257D

DC_1A-3A-19A-42C_n257E

DC_1A-3A-19A-42C_n257F

DC_1A-3A-19A-42C_n257G

DC_1A-3A-19A-42C_n257H

DC_1A-3A-19A-42C_n257I

DC_1A_n257A

DC_3A_n257A

DC_3A_n257G

DC_3A_n257H

DC_3A_n257I

DC_19A_n257A

DC_42A_n257A

DC_1A-3A-21A-42A_n257A

DC_1A-3A-21A-42C_n257A

DC_1A-3A-21A-42C_n257D

DC_1A-3A-21A-42C_n257E

DC_1A-3A-21A-42C_n257F

DC_1A-3A-21A-42C_n257G

DC_1A-3A-21A-42C_n257H

DC_1A-3A-21A-42C_n257I

DC_1A_n257A

DC_3A_n257A

DC_3A_n257G

DC_3A_n257H

DC_3A_n257I

DC_3A_n257J

DC_21A_n257A

DC_42A_n257A

DC_1A-19A-21A-42A_n257A

DC_1A-19A-21A-42A_n257G

DC_1A-19A-21A-42A_n257H

DC_1A-19A-21A-42A_n257I

DC_1A-19A-21A-42C_n257A

DC_1A-19A-21A-42C_n257D

DC_1A-19A-21A-42C_n257E

DC_1A-19A-21A-42C_n257F

DC_1A-19A-21A-42C_n257G

DC_1A-19A-21A-42C_n257H

DC_1A-19A-21A-42C_n257I

DC_1A_n257A

DC_1A_n257G

DC_1A_n257H

DC_1A_n257I

DC_19A_n257A

DC_21A_n257A

DC_21A_n257G

DC_21A_n257H

DC_21A_n257I

DC_42A_n257A

DC_2A-14A-30A-66A_n260A

DC_2A-14A-30A-66A_n260G

DC_2A-14A-30A-66A_n260H

DC_2A-14A-30A-66A_n260I

DC_2A_n260A

DC_2A_n260G

DC_2A_n260H

DC_2A_n260I

DC_14A_n260A

DC_14A_n260G

DC_14A_n260H

DC_14A_n260I

DC_30A_n260A

DC_30A_n260G

DC_30A_n260H

DC_30A_n260I

DC_66A_n260A

DC_66A_n260G

DC_66A_n260H

DC_66A_n260I

NOTE 1: Uplink EN-DC configurations are the configurations supported by the present release of specifications.

5.5B.5.5 Void

5.5B.6 Inter-band EN-DC including FR1 and FR2

Supported channel bandwidths for E-UTRA operating bands and CA configurations are defined in TS 36.521-1 [10] and for NR operating bands and CA configurations in TS 38.521-1 [8], TS 38.521-2 [9] and present document.

5.5B.6.1 Void

5.5B.6.2 Inter-band EN-DC configurations including FR1 and FR2 (three bands)

Table 5.5B.6.2-1: Inter-band EN-DC configurations including FR1 and FR2 (three bands)

EN-DC configuration

Uplink EN-DC configuration (NOTE 1)

DC_1A_n77A-n257A2

DC_1A_n77A-n257D2

DC_1A_n77A-n257E2

DC_1A_n77A-n257F2

DC_1A_n77C-n257A2

DC_1A_n77C-n257D2

DC_1A_n77C-n257E2

DC_1A_n77C-n257F2

DC_1A_n77A

DC_1A_n257A

DC_1A_n77A-n257A

DC_1A_n78A-n257A2

DC_1A_n78A-n257D2

DC_1A_n78A-n257E2

DC_1A_n78A-n257F2

DC_1A_n78C-n257A2

DC_1A_n78C-n257D2

DC_1A_n78C-n257E2

DC_1A_n78C-n257F2

DC_1A_n78A

DC_1A_n257A

DC_1A_n78A-n257A

DC_1A_n79A-n257A2

DC_1A_n79A-n257D2

DC_1A_n79A-n257E2

DC_1A_n79A-n257F2

DC_1A_n79C-n257A2

DC_1A_n79C-n257D2

DC_1A_n79C-n257E2

DC_1A_n79C-n257F2

DC_1A_n79A

DC_1A_n257A

DC_1A_n79A-n257A

DC_3A_n77A-n257A2

DC_3A_n77A-n257D2

DC_3A_n77A-n257E2

DC_3A_n77A-n257F2

DC_3A_n77C-n257A2

DC_3A_n77C-n257D2

DC_3A_n77C-n257E2

DC_3A_n77C-n257F2

DC_3A_n77A

DC_3A_n257A

DC_3A_n77A-n257A

DC_3A_n78A-n257A2

DC_3A_n78A-n257D2

DC_3A_n78A-n257E2

DC_3A_n78A-n257F2

DC_3A_n78C-n257A2

DC_3A_n78C-n257D2

DC_3A_n78C-n257E2

DC_3A_n78C-n257F2

DC_3A_n78A

DC_3A_n257A

DC_3A_n78A-n257A

DC_3A_n79A-n257A2

DC_3A_n79A-n257D2

DC_3A_n79A-n257E2

DC_3A_n79A-n257F2

DC_3A_n79C-n257A2

DC_3A_n79C-n257D2

DC_3A_n79C-n257E2

DC_3A_n79C-n257F2

DC_3A_n79A

DC_3A_n257A

DC_3A_n79A-n257A

DC_5A_n78A-n257A2

DC_5A_n78A

DC_5A_n257A

DC_7A_n78A-n257A2

DC_7A_n78A

DC_7A_n257A

DC_7A-7A_n78A-n2572A

DC_7A_n78A

DC_7A_n257A

DC_7A_n78A-n257A

DC_19A_n77A-n257A2

DC_19A_n77A-n257D2

DC_19A_n77A-n257E2

DC_19A_n77A-n257F2

DC_19A_n77C-n257A2

DC_19A_n77C-n257D2

DC_19A_n77C-n257E2

DC_19A_n77C-n257F2

DC_19A_n77A

DC_19A_n257A

DC_19A_n77A-n257A

DC_19A_n78A-n257A2

DC_19A_n78A-n257D2

DC_19A_n78A-n257E2

DC_19A_n78A-n257F2

DC_19A_n78C-n257A2

DC_19A_n78C-n257D2

DC_19A_n78C-n257E2

DC_19A_n78C-n257F2

DC_19A_n78A

DC_19A_n257A

DC_19A_n78A-n257A

DC_19A_n79A-n257A2

DC_19A_n79A-n257D2

DC_19A_n79A-n257E2

DC_19A_n79A-n257F2

DC_19A_n79C-n257A2

DC_19A_n79C-n257D2

DC_19A_n79C-n257E2

DC_19A_n79C-n257F2

DC_19A_n79A

DC_19A_n257A

DC_19A_n79A-n257A

DC_21A_n77A-n257A2

DC_21A_n77A

DC_21A_n257A

DC_21A_n78A-n257A2

DC_21A_n78A

DC_21A_n257A

DC_21A_n79A-n257A2

DC_21A_n79A

DC_21A_n257A

NOTE 1: Uplink EN-DC configurations are the configurations supported by the present release of specifications.

NOTE 2: Applicable for UE supporting inter-band EN-DC with mandatory simultaneous Rx/Tx capability

5.5B.6.3 Inter-band EN-DC configurations including FR1 and FR2 (four bands)

Table 5.5B.6.3-1: Inter-band EN-DC configurations including FR1 and FR2 (four bands)

EN-DC configuration

Uplink EN-DC configuration (NOTE 1)

DC_1A-3A_n78A-n257A2

DC_1A-3A_n78A-n257G2

DC_1A-3A_n78A-n257H2

DC_1A-3A_n78A-n257I2

DC_1A_n78A

DC_1A_n257A

DC_1A_n257D

DC_1A_n257G

DC_1A_n257H

DC_1A_n257I

DC_3A_n78A

DC_3A_n257A

DC_3A_n257D

DC_3A_n257G

DC_3A_n257H

DC_3A_n257I

DC_1A-5A_n78A-n257A

DC_1A_n78A

DC_1A_n257A

DC_5A_n78A

DC_5A_n257A

DC_1A-7A_n78A-n257A

DC_1A_n78A

DC_1A_n257A

DC_7A_n78A

DC_7A_n257A

DC_1A-7A-7A_n78A-n257A

DC_1A_n78A

DC_1A_n257A

DC_7A_n78A

DC_7A_n257A

DC_3A-5A_n78A-n257A

DC_3A_n78A

DC_3A_n257A

DC_5A_n78A

DC_5A_n257A

DC_3A-7A_n78A-n257A

DC_3A_n78A

DC_3A_n257A

DC_7A_n78A

DC_7A_n257A

DC_3A-7A-7A_n78A-n257A

DC_3A_n78A

DC_3A_n257A

DC_7A_n78A

DC_7A_n257A

DC_5A-7A_n78A-n257A

DC_5A_n78A

DC_5A_n257A

DC_7A_n78A

DC_7A_n257A

DC_5A-7A-7A_n78A-n257A

DC_5A_n78A

DC_5A_n257A

DC_7A_n78A

DC_7A_n257A

NOTE 1: Uplink EN-DC configurations are the configurations supported by the present release of specifications.

NOTE 2: Applicable for UE supporting inter-band EN-DC with mandatory simultaneous Rx/Tx capability.

5.5B.6.4 Inter-band EN-DC configurations including FR1 and FR2 (five bands)

Table 5.5B.6.4-1: Inter-band EN-DC configurations including FR1 and FR2 (five bands)

EN-DC configuration

Uplink EN-DC configuration (NOTE 1)

DC_1A-3A-5A_n78A-n257A

DC_1A_n78A

DC_1A_n257A

DC_3A_n78A

DC_3A_n257A

DC_5A_n78A

DC_5A_n257A

DC_1A-3A-7A_n78A-n257A

DC_1A_n78A

DC_1A_n257A

DC_3A_n78A

DC_3A_n257A

DC_7A_n78A

DC_7A_n257A

DC_1A-3A-7A-7A_n78A-n257A

DC_1A_n78A

DC_1A_n257A

DC_3A_n78A

DC_3A_n257A

DC_7A_n78A

DC_7A_n257A

DC_1A-5A-7A_n78A-n257A

DC_1A_n78A

DC_1A_n257A

DC_5A_n78A

DC_5A_n257A

DC_7A_n78A

DC_7A_n257A

DC_1A-5A-7A-7A_n78A-n257A

DC_1A_n78A

DC_1A_n257A

DC_5A_n78A

DC_5A_n257A

DC_7A_n78A

DC_7A_n257A

DC_3A-5A-7A_n78A-n257A

DC_3A_n78A

DC_3A_n257A

DC_5A_n78A

DC_5A_n257A

DC_7A_n78A

DC_7A_n257A

DC_3A-5A-7A-7A_n78A-n257A

DC_3A_n78A

DC_3A_n257A

DC_5A_n78A

DC_5A_n257A

DC_7A_n78A

DC_7A_n257A

NOTE 1: Uplink EN-DC configurations are the configurations supported by the present release of specifications.

5.5B.6.5 Inter-band EN-DC configurations including FR1 and FR2 (six bands)

Table 5.5B.6.5-1: Inter-band EN-DC configurations including FR1 and FR2 (six bands)

EN-DC configuration

Uplink EN-DC configuration (NOTE 1)

DC_1A-3A-5A-7A_n78A-n257A

DC_1A_n78A

DC_1A_n257A

DC_3A_n78A

DC_3A_n257A

DC_5A_n78A

DC_5A_n257A

DC_7A_n78A

DC_7A_n257A

NOTE 1: Uplink EN-DC configurations are the configurations supported by the present release of specifications.

5.5B.7 Inter-band NR-DC between FR1 and FR2

Supported channel bandwidths for E-UTRA operating bands and CA configurations are defined in TS 36.521-1 [10] and for NR operating bands and CA configurations in TS 38.521-1 [8], TS 38.521-2 [9] and present document.

5.5B.7.0 General

The configurations and bandwidth combination sets for the FR1-FR2 NR-DC combinations in the following sub-section are defined in the tables for FR1-FR2 carrier aggregation in section 5.5A.1.

5.5B.7.1 Inter-band NR-DC configurations between FR1 and FR2 (two bands)

Table 5.5B.7-1: Inter-band NR-DC configurations between FR1 and FR2 (two bands)

Downlink NR-DC configuration

Uplink NR-DC configuration

DC_n77A-n257A

DC_n77A-n257D

DC_n77A-n257E

DC_n77A-n257F

DC_n77A-n257G

DC_n77A-n257H

DC_n77A-n257I

DC_n77A-n257J

DC_n77A-n257K

DC_n77A-n257L

DC_n77A-n257M

DC_n77C-n257A

DC_n77C-n257D

DC_n77C-n257E

DC_n77C-n257F

DC_n77A-n257A

DC_n78A-n257A

DC_n78A-n257D

DC_n78A-n257E

DC_n78A-n257F

DC_n78A-n257G

DC_n78A-n257H

DC_n78A-n257I

DC_n78A-n257J

DC_n78A-n257K

DC_n78A-n257L

DC_n78A-n257M

DC_n78C-n257A

DC_n78C-n257D

DC_n78C-n257E

DC_n78C-n257F

DC_n78A-n257A

DC_n79A-n257A

DC_n79A-n257D

DC_n79A-n257E

DC_n79A-n257F

DC_n79A-n257G

DC_n79A-n257H

DC_n79A-n257I

DC_n79A-n257J

DC_n79A-n257K

DC_n79A-n257L

DC_n79A-n257M

DC_n79C-n257A

DC_n79C-n257D

DC_n79C-n257E

DC_n79C-n257F

DC_n79A-n257A

5.5E Configuration for V2X operation

5.5E.1 General

The operating bands and bandwidth classes are specified for V2X operation.

5.5E.2 Intra-band contiguous V2X operation in FR1

Table 5.5E.2-1: Intra-band contiguous V2X configurations

V2X

configuration

SL transmission

V2X_(n)47AA

E-UTRA Band 47 or NR band n47

NOTE 1: Only single switched SL is supported.

5.5E.3 Intra-band non-contiguous V2X operation in FR1

Table 5.5E.3-1: Intra-band non-contiguous V2X configurations

V2X

configuration

SL transmission

V2X_47A_n47A

E-UTRA Band 47 or NR band n47

NOTE 1: Only single switched SL is supported.

5.5E.4 Inter-band V2X operation in FR1

5.5E.4.1 Inter-band V2X configurations within FR1 (two bands)

Table 5.5E.4.1-1: Inter-band V2X configurations

V2X

configuration

V2X transmission configuration

V2X_20A_n38A

V2X_20A_n38A

V2X_n71A_47A

V2X_n71A_47A

NOTE 1: V2X transmission configurations are the configurations supported by the present release of specifications.