A.4.3.2C NR SUL Physical Layer Baseline Implementation Capabilities
38.508-23GPP5GSPart 2: Common Implementation Conformance Statement (ICS) proformaRelease 17TSUser Equipment (UE) conformance specification
A.4.3.2C.1 General NR SUL capabilities
Table A.4.3.2C.1-1: Uplink NR SUL capabilities (for one or more of the supported NR SULconfigurations)
Item |
Bandwidth Class |
Ref. |
Comments |
1 |
UL NR SUL with 2 carriers |
38.101-1, 5.5C |
|
2 |
UL NR SUL with 3 carriers |
38.101-1, 5.5C |
A.4.3.2C.2 SUL band combinations without CA
Table A.4.3.2C.2-1: Supported SUL configurations without CA
SUL configuration / Item (Note 1) |
Release |
Supported |
Supported Bandwidth Combination Set(s) |
Supported ULTxSwitching Band Pair (Note 2, 3) |
SUL_n41A-n83A |
Rel-17 |
|||
SUL_n78A-n80A |
Rel-15 |
|||
SUL_n78A-n81A |
Rel-15 |
|||
SUL_n78A-n82A |
Rel-15 |
|||
SUL_n78A-n83A |
Rel-15 |
|||
SUL_n78A-n84A |
Rel-15 |
|||
SUL_n78A-n86A |
Rel-15 |
|||
SUL_n79A-n80A |
Rel-15 |
|||
SUL_n79A-n81A |
Rel-15 |
|||
SUL_n79A-n83A |
Rel-17 |
|||
Note 1: Notation used for SUL configurations is according to TS 38.101-1 [23] Table 5.5C-1, e.g. ‘SUL_n78A-n80A’ indicates SUL operation on NR bands n78 and n80 with UL CA Bandwidth Class A on both bands. Note 2: The ULTxSwitching capability can be reported on SUL band combinations. The UE supplier shall indicate SUL band pairs on which it supports ULTxSwitching. For this release of specification valid choices are ’N’ and ‘nX-nY’, where both nX and nY are NR bands. For example, for SUL_n78A-n80A, N would mean not supporting ULTxSwitching, ‘n78-n80’ would mean supporting of ULTxSwitching on this band pair. The ULTxSwitching is only tested with 2 UL CCs, so UE is allowed to report ‘N’ by default for SUL configuration with > 2 component carriers. Note 3: ULSwitching(Table A.4.3.2C.2-1) shall return all supported SUL Configurations where at least one SUL band pair was declared in column “Supported ULTxSwitching Band Pair". |
A.4.3.2C.3 SUL band combinations with CA
Table A.4.3.2C.3-1: Supported SUL configurations with Intra-band non-contiguous CA
NR SUL with CA configuration / Item (Note 1) |
Release |
Supported |
Supported SUL configuration in UL |
Supported Bandwidth Combination Set(s) |
Supported ULTxSwitching Band Pair (Note 2, 3) |
TBD |
TBD |
||||
Note 1: Notation used for SUL configurations is according to TS 38.101-1 [23] Table 5.5C-2. Note 2: The ULTxSwitching capability can be reported on SUL band combinations. The UE supplier shall indicate SUL band pairs on which it supports ULTxSwitching. For this release of specification valid choices are ’N’ and ‘nX-nY’, where both nX and nY are NR bands. For example, for SUL_n78A-n80A, N would mean not supporting ULTxSwitching, ‘n78-n80’ would mean supporting of ULTxSwitching on this band pair. Note 3: ULSwitching(Table A.4.3.2C.2-1) shall return all supported SUL Configurations where at least one SUL band pair was declared in column “Supported ULTxSwitching Band Pair". |
Table A.4.3.2C.3-2: Supported SUL configurations with Intra-band contiguous CA
NR SUL configuration / Item (Note 1) |
Release |
Supported |
Supported SUL configuration in UL |
Supported Bandwidth Combination Set(s) |
Supported ULTxSwitching Band Pair (Note 2, 3) |
SUL_n41C-n83A |
Rel-17 |
||||
SUL_n78C-n80A |
Rel-17 |
||||
SUL_n78C-n84A |
Rel-17 |
||||
SUL_n79C-n83A |
Rel-17 |
||||
Note 1: Notation used for SUL configurations is according to TS 38.101-1 [23] Table 5.5C-3,. e.g. ‘SUL_n41C-n83A’ indicates SUL operation on NR bands n41 and n83 with DL CA Bandwidth Class C on band n41. Note 2: The ULTxSwitching capability can be reported on SUL band combinations. The UE supplier shall indicate SUL band pairs on which it supports ULTxSwitching. For this release of specification valid choices are ’N’ and ‘nX-nY’, where both nX and nY are NR bands. For example, for SUL_n78A-n80A, N would mean not supporting ULTxSwitching, ‘n78-n80’ would mean supporting of ULTxSwitching on this band pair. Note 3: ULSwitching(Table A.4.3.2C.2-1) shall return all supported SUL Configurations where at least one SUL band pair was declared in column “Supported ULTxSwitching Band Pair". |
Table A.4.3.2C.3-3: Supported SUL configurations with Inter-band CA
NR SUL configuration / Item (Note 1) |
Release |
Supported |
Supported SUL configuration in UL |
Supported Bandwidth Combination Set(s) |
Supported ULTxSwitching Band Pair (Note 2, 3) |
CA_n1A_SUL_n78A-n80A |
Rel-17 |
||||
CA_n1A_SUL_n78A-n84A |
Rel-17 |
||||
CA_n3A_SUL_n78A-n80A |
Rel-17 |
||||
CA_n28A_SUL_n41A-n83A |
Rel-17 |
||||
CA_n28A_SUL_n79A-n83A |
Rel-17 |
||||
Note 1: Notation used for SUL configurations is according to TS 38.101-1 [23] Table 5.5C-4. e.g. ‘CA_n1A_SUL_n78A-n84A’ indicates SUL operation on NR bands n1, n78 and n84 with DL CA Bandwidth Class A on bands n1 and n78. Note 2: The ULTxSwitching capability can be reported on SUL band combinations. The UE supplier shall indicate SUL band pairs on which it supports ULTxSwitching. For this release of specification valid choices are ’N’ and ‘nX-nY’, where both nX and nY are NR bands. For example, for SUL_n78A-n80A, N would mean not supporting ULTxSwitching, ‘n78-n80’ would mean supporting of ULTxSwitching on this band pair. Note 3: ULSwitching(Table A.4.3.2C.2-1) shall return all supported SUL Configurations where at least one SUL band pair was declared in column “Supported ULTxSwitching Band Pair". |