A.4.3.6 Measurement Capabilities
38.508-23GPP5GSPart 2: Common Implementation Conformance Statement (ICS) proformaRelease 17TSUser Equipment (UE) conformance specification
Table A.4.3.6-1: UE Measurement Capabilities
Item |
UE Measurement Capabilities |
Ref. |
Release |
Mnemonic |
M |
If indicated "Yes" the feature shall be implemented and successfully tested for the corresponding release |
Comments |
||||||||||||||||
1 |
Support NR measurements and events A triggered reporting |
38.306, 4.2.9 |
Rel-15 |
pc_eventA_MeasAndReport |
Yes |
||||||||||||||||||
2 |
Support two independent measurement gap configurations for FR1 and FR2 |
38.306, 4.2.9 |
Rel-15 |
pc_independentGapConfig |
No |
||||||||||||||||||
3 |
Support NR intra-frequency and inter-frequency measurements and at least periodical reporting |
38.306, 4.2.9 |
Rel-15 |
pc_intraAndInterF_MeasAndReport |
Yes |
||||||||||||||||||
4 |
Support CSI-RSRP and CSI-RSRQ measurement as specified in TS38.215 [21], where CSI-RS resource is configured with an associated SS/PBCH |
38.306, 4.2.9 |
Rel-15 |
pc_csi_RSRP_AndRSRQ_MeasWithSSB |
No |
||||||||||||||||||
5 |
Support inter-RAT E-UTRA measurements and events B triggered reporting |
38.306, 4.2.9 |
Rel-15 |
pc_eventB_MeasAndReport |
Yes |
||||||||||||||||||
6 |
Support SS-SINR measurents |
38.306, 4.2.9 |
Rel-15 |
pc_ss_SINR_Meas |
No |
||||||||||||||||||
7 |
Support acquisition of relevant information from a neighbouring E-UTRA cell by reading the SI of the neighbouring cell and reporting the acquired information to the network as specified in TS 38.331 [9] when the EN-DC is not configured. |
38.306, 4.2.9 |
Rel-15 |
pc_eutra_CGI_Reporting |
Yes |
||||||||||||||||||
8 |
Support acquisition of relevant information from a neighbouring intra-frequency or inter-frequency NR cell by reading the SI of the neighbouring cell and reporting the acquired information to the network as specified in TS 38.331 [9] when EN-DC is not configured. |
38.306, 4.2.9 |
Rel-15 |
pc_nr_CGI_Reporting |
Yes |
||||||||||||||||||
9 |
Support acquisition of relevant information from a neighbouring intra-frequency or inter-frequency NR cell by reading the SI of the neighbouring cell and reporting the acquired information to the network as specified in TS 38.331 [9] when the EN-DC is configured. |
38.306, 4.2.9 |
Rel-15 |
pc_nr_CGI_Reporting_ENDC |
Yes |
||||||||||||||||||
10 |
Support shorter measurement gap length (i.e. gp2 and gp3) for independent measurement gap configuration on FR1 and per-UE gap in (NG)EN-DC. |
36.331, 6.3.6 |
Rel-15 |
pc_gp2_gp3_en_dc |
No |
||||||||||||||||||
11 |
Support NR supports gap pattern 4 for independent measurement gap configuration on FR1 and per-UE gap in (NG)EN-DC |
36.331, 6.3.6 |
Rel-15 |
pc_gp4_en_dc |
No |
||||||||||||||||||
12 |
Support NR supports gap pattern 5 for independent measurement gap configuration on FR1 and per-UE gap in (NG)EN-DC |
36.331, 6.3.6 |
Rel-15 |
pc_gp5_en_dc |
No |
||||||||||||||||||
13 |
Support NR supports gap pattern 6 for independent measurement gap configuration on FR1 and per-UE gap in (NG)EN-DC |
36.331, 6.3.6 |
Rel-15 |
pc_gp6_en_dc |
No |
||||||||||||||||||
14 |
Support NR supports gap pattern 7 for independent measurement gap configuration on FR1 and per-UE gap in (NG)EN-DC |
36.331, 6.3.6 |
Rel-15 |
pc_gp7_en_dc |
No |
||||||||||||||||||
15 |
Support NR supports gap pattern 8 for independent measurement gap configuration on FR1 and per-UE gap in (NG)EN-DC |
36.331, 6.3.6 |
Rel-15 |
pc_gp8_en_dc |
No |
||||||||||||||||||
16 |
Support NR supports gap pattern 9 for independent measurement gap configuration on FR1 and per-UE gap in (NG)EN-DC |
36.331, 6.3.6 |
Rel-15 |
pc_gp9_en_dc |
No |
||||||||||||||||||
17 |
Support NR supports gap pattern 10 for independent measurement gap configuration on FR1 and per-UE gap in (NG)EN-DC |
36.331, 6.3.6 |
Rel-15 |
pc_gp10_en_dc |
No |
||||||||||||||||||
18 |
Support NR supports gap pattern 11 for independent measurement gap configuration on FR1 and per-UE gap in (NG)EN-DC |
36.331, 6.3.6 |
Rel-15 |
pc_gp11_en_dc |
No |
||||||||||||||||||
19 |
Support measurement gap pattern 2 configured by NR RRC. |
38.306, 4.2.9 |
Rel-15 |
pc_gp2_nr |
No |
||||||||||||||||||
20 |
Support measurement gap pattern 3 configured by NR RRC. |
38.306, 4.2.9 |
Rel-15 |
pc_gp3_nr |
No |
||||||||||||||||||
21 |
Support measurement gap pattern 4 configured by NR RRC. |
38.306, 4.2.9 |
Rel-15 |
pc_gp4_nr |
No |
||||||||||||||||||
22 |
Support measurement gap pattern 5 configured by NR RRC. |
38.306, 4.2.9 |
Rel-15 |
pc_gp5_nr |
No |
||||||||||||||||||
23 |
Support measurement gap pattern 6 configured by NR RRC. |
38.306, 4.2.9 |
Rel-15 |
pc_gp6_nr |
No |
||||||||||||||||||
24 |
Support measurement gap pattern 7 configured by NR RRC. |
38.306, 4.2.9 |
Rel-15 |
pc_gp7_nr |
No |
||||||||||||||||||
25 |
Support measurement gap pattern 8 configured by NR RRC. |
38.306, 4.2.9 |
Rel-15 |
pc_gp8_nr |
No |
||||||||||||||||||
26 |
Support measurement gap pattern 9 configured by NR RRC. |
38.306, 4.2.9 |
Rel-15 |
pc_gp9_nr |
No |
||||||||||||||||||
27 |
Support measurement gap pattern 10 configured by NR RRC. |
38.306, 4.2.9 |
Rel-15 |
pc_gp10_nr |
No |
||||||||||||||||||
28 |
Support measurement gap pattern 11 configured by NR RRC. |
38.306, 4.2.9 |
Rel-15 |
pc_gp11_nr |
No |
||||||||||||||||||
29 |
Support measurement gap pattern 12 configured by NR RRC. |
38.306, 4.2.9 |
Rel-15 |
pc_gp12_nr |
No |
||||||||||||||||||
30 |
Support measurement gap pattern 15 configured by NR RRC. |
38.306, 4.2.9 |
Rel-15 |
pc_gp15_nr |
No |
||||||||||||||||||
31 |
Support measurement gap pattern 16 configured by NR RRC. |
38.306, 4.2.9 |
Rel-15 |
pc_gp16_nr |
No |
||||||||||||||||||
32 |
Support measurement gap pattern 17 configured by NR RRC. |
38.306, 4.2.9 |
Rel-15 |
pc_gp17_nr |
No |
||||||||||||||||||
34 |
Support measurement gap pattern 18 configured by NR RRC. |
38.306, 4.2.9 |
Rel-15 |
pc_gp18_nr |
No |
||||||||||||||||||
35 |
Support measurement gap pattern 19 configured by NR RRC. |
38.306, 4.2.9 |
Rel-15 |
pc_gp19_nr |
No |
||||||||||||||||||
36 |
Support measurement gap pattern 20 configured by NR RRC. |
38.306, 4.2.9 |
Rel-15 |
pc_gp20_nr |
No |
||||||||||||||||||
37 |
Support measurement gap pattern 21 configured by NR RRC. |
38.306, 4.2.9 |
Rel-15 |
pc_gp21_nr |
No |
||||||||||||||||||
38 |
Support measurement gap pattern 22 configured by NR RRC. |
38.306, 4.2.9 |
Rel-15 |
pc_gp22_nr |
No |
||||||||||||||||||
39 |
Support measurement gap pattern 23 configured by NR RRC. |
38.306, 4.2.9 |
Rel-15 |
pc_gp23_nr |
No |
||||||||||||||||||
40 |
Support CSI-RSRP and CSI-RSRQ measurement as specified in TS38.215 [21], where CSI-RS resource is configured without an associated SS/PBCH |
38.306, 4.2.9 |
Rel-15 |
pc_csi_RSRP_AndRSRQ_MeasWithoutSSB |
No |
||||||||||||||||||
41 |
Support CSI-RS based Radio Link Monitoring for FR1 |
38.306, 4.2.9 |
Rel-15 |
pc_CSI_RS_RLM_FR1 |
Yes |
If the UE supports this feature, the UE needs to report maxNumberResource-CSI-RS-RLM in its capability report. If the UE doesn’t support CSI-RS based RLM, it will not include this IE in its capability report. |
|||||||||||||||||
41a |
Support CSI-RS based Radio Link Monitoring for FR2 |
38.306, 4.2.9 |
Rel-15 |
pc_CSI_RS_RLM_FR2 |
Yes |
If the UE supports this feature, the UE needs to report maxNumberResource-CSI-RS-RLM in its capability report. If the UE doesn’t support CSI-RS based RLM, it will not include this IE in its capability report. |
|||||||||||||||||
42 |
Support of E-UTRA RS-SINR measurements |
38.306, 4.2.10 |
Rel-15 |
pc_RS_SINR_MeasEUTRA |
No |
||||||||||||||||||
43 |
Support of SFTD measurements between a E-UTRA PCell and an NR PSCell in FDD |
38.306, 4.2.9 |
Rel-15 |
pc_SFTD_MeasPSCell_MRDC_FDD |
No |
The SFTD measurement support should be indicated in MRDC capabilities for EN-DC. The support needs to be declared for FDD and TDD separately |
|||||||||||||||||
44 |
Support of SFTD measurements between a E-UTRA PCell and an NR PSCell in TDD |
38.306, 4.2.9 |
Rel-15 |
pc_SFTD_MeasPSCell_MRDC_TDD |
No |
The SFTD measurement support should be indicated in MRDC capabilities for EN-DC. The support needs to be declared for FDD and TDD separately |
|||||||||||||||||
45 |
Support of relaxed RRM measurements of neighbour cells in RRC_IDLE/RRC_INACTIVE |
38.306, 5.6 |
Rel-16 |
pc_Relaxed_Measurement |
No |
||||||||||||||||||
46 |
Support of SFTD measurements between a E-UTRA PCell and an NR neighbour cell in FDD |
38.306, 4.2.9 |
Rel-15 |
pc_SFTD_MeasNR_Cell_FDD |
No |
The support needs to be declared for FDD and TDD separately The SFTD measurement support can only be indicated in MRDC capabilities for EN-DC |
|||||||||||||||||
47 |
Support of SFTD measurements between a E-UTRA PCell and an NR neighbour cell in TDD |
38.306, 4.2.9 |
Rel-15 |
pc_SFTD_MeasNR_Cell_TDD |
No |
The support needs to be declared for FDD and TDD separately The SFTD measurement support can only be indicated in MRDC capabilities for EN-DC |
|||||||||||||||||
48 |
Support of SFTD measurements between a NR PCell and an NR neighbour cell in FDD |
38.306, 4.2.9 |
Rel-15 |
pc_SFTD_MeasNR_Neigh_FDD |
No |
The support needs to be declared for FDD and TDD separately |
|||||||||||||||||
49 |
Support of SFTD measurements between a NR PCell and an NR neighbour cell in TDD |
38.306, 4.2.9 |
Rel-15 |
pc_SFTD_MeasNR_Neigh_TDD |
No |
The support needs to be declared for FDD and TDD separately |
|||||||||||||||||
50 |
Support of SFTD measurements between a NR PCell and an NR PSCell in FDD |
38.306, 4.2.9 |
Rel-15 |
pc_SFTD_MeasPSCell_NRDC_FDD |
No |
The SFTD measurement support should be indicated in UE-NR-Capability |
|||||||||||||||||
51 |
Support of SFTD measurements between a NR PCell and an NR PSCell in TDD |
38.306, 4.2.9 |
Rel-15 |
pc_SFTD_MeasPSCell_NRDC_TDD |
No |
The SFTD measurement support should be indicated in UE-NR-Capability |
|||||||||||||||||
52 |
Support of acquisition of CGI related information from a neighbouring intra-frequency or inter-frequency NPN CAG cell |
38.306, 4.2.9 |
Rel-16 |
pc_nr_CGI_Reporting_NPN_r16 |
No |
||||||||||||||||||
53 |
Supports periodic EUTRA measurement and reporting. |
38.306, 4.2.9 |
Rel-15 |
pc_periodicEUTRA_MeasAndReport |
Yes |
||||||||||||||||||
54 |
Support configuration of NR SSB measurements in RRC_IDLE/RRC_INACTIVE and reporting of the corresponding results upon network request as specified in TS 38.331 [9] |
38.306, 4.2.9 |
Rel-16 |
pc_idleInactiveNR_MeasReport |
No |
||||||||||||||||||
55 |
Support configuration of E-UTRA measurements in RRC_IDLE/RRC_INACTIVE and reporting of the corresponding results upon network request as specified in TS 38.331 [9] |
38.306, 4.2.9 |
Rel-16 |
pc_idleInactiveEUTRA_MeasReport |
No |
||||||||||||||||||
56 |
Support SRS-RSRP measurements between a NR Pcell and an interfering UE, upon network request as specified in 38.331 [9] |
38.306, 4.2.9 |
Rel-16 |
pc_nr_CLI_Reporting_r16 |
No |
If the UE supports this feature, the UE needs to report maxNumberCLI-SRS-RSRP-r16 and maxNumberPerSlotCLI-SRS-RSRP-r16 If the UE doesn’t support CLI SRS-RSRP measurement, it will not include this IE in its capability report. |