B.2 Normal test environment

38.176-23GPPIntegrated Access and Backhaul (IAB) conformance testingNRPart 2: radiated conformance testingRelease 17TS

When a normal test environment is specified for a test, the test should be performed within the minimum and maximum limits of the conditions stated in table B.1.

Table B.1: Limits of conditions for normal test environment

Condition

Minimum

Maximum

Barometric pressure

86 kPa

106 kPa

Temperature

15 °C

30 °C

Relative humidity

20 %

85 %

Power supply

Nominal, as declared by the manufacturer

Vibration

Negligible

The ranges of barometric pressure, temperature and humidity represent the maximum variation expected in the uncontrolled environment of a test laboratory. If it is not possible to maintain these parameters within the specified limits, the actual values shall be recorded in the test report.

NOTE: This may, for instance, be the case for measurements of radiated emissions performed on an open field test site.