6.0 Introduction
36.523-13GPPEvolved Universal Terrestrial Radio Access (E-UTRA) and Evolved Packet Core (EPC)Part 1: Protocol conformance specificationRelease 17TSUser Equipment (UE) conformance specification
6.0.1 PLMN and TAC
The PLMN numbers indicated in Table 6.0.1-1 are used in test cases to associate a cell with an MCC and MNC for that cell. If no PLMN is explicitly specified, the default value is PLMN 1.
Table 6.0.1-1: Tracking Area Identity (TAI) in System Information Block Type 1
broadcast on the BCCH (E-UTRAN)
PLMN |
MCC1 |
MCC2 |
MCC3 |
MNC1 |
MNC2 |
MNC3 |
TAC |
1 |
0 |
0 |
1 |
0 |
1 |
Not present |
See Table 6.0.1-2 |
2 |
0 |
0 |
2 |
1 |
1 |
Not present |
|
3 |
0 |
0 |
3 |
2 |
1 |
Not present |
|
4 |
0 |
0 |
4 |
3 |
1 |
Not present |
|
5 |
0 |
0 |
5 |
4 |
1 |
Not present |
|
6 |
0 |
0 |
6 |
5 |
1 |
Not present |
|
7 |
0 |
0 |
7 |
6 |
1 |
Not present |
|
8 |
0 |
0 |
8 |
7 |
1 |
Not present |
|
9 |
0 |
0 |
9 |
0 |
2 |
Not present |
|
10 |
0 |
1 |
0 |
1 |
2 |
Not present |
|
11 |
0 |
1 |
1 |
2 |
2 |
Not present |
|
12 |
0 |
1 |
2 |
3 |
2 |
Not present |
|
13 |
0 |
0 |
2 |
8 |
1 |
Not present |
|
14 |
0 |
0 |
2 |
9 |
1 |
Not present |
|
15 |
0 |
0 |
1 |
1 |
1 |
Not present |
|
16 |
0 |
0 |
1 |
2 |
1 |
Not present |
|
17 |
0 |
0 |
1 |
3 |
1 |
Not present |
|
18 |
0 |
0 |
1 |
4 |
1 |
Not present |
NOTE: The Location Area Information (LAI) for UTRA and GSM could be re-used from TS 34.123-1 clause 6.
If no TAC for E-UTRAN cell is explicitly specified in the test case description, the TACs for E-UTRAN cells indicated in Table 6.0.1-2 are used in the test case.
Table 6.0.1-2: Tracking Area Code (TAC) for E-UTRAN cells
cell ID |
TAC |
Cell 1 |
1 |
Cell 2 |
2 |
Cell 3 |
3 |
Cell 4 |
4 |
Cell 6 |
6 |
Cell 10 |
10 |
Cell 11 |
11 |
Cell 12 |
12 |
Cell 13 |
13 |
Cell 14 |
14 |
Cell 23 |
23 |
Cell 28 |
28 |
Cell 29 |
29 |
Cell 30 |
30 |
If no RAI for UTRAN cell is explicitly specified in the test case description, the RAI for UTRAN cells indicated in Table 4.4.4-2 in [18] are used in the test case.
6.0.2 Other
6.0.2.1 Values of parameters calculated by the UE
Values of some parameters calculated by the UE, such as Srxlev, are provided in the test case description without explicitly taking into account SS signal generation and UE measurement uncertainties. These values are for information purpose only and therefore shall not be directly used to determine the UE behaviour; instead a range of values resulting from uncertainties specific for given test case conditions shall be considered.