6.0 Introduction

36.523-13GPPEvolved Universal Terrestrial Radio Access (E-UTRA) and Evolved Packet Core (EPC)Part 1: Protocol conformance specificationRelease 17TSUser Equipment (UE) conformance specification

6.0.1 PLMN and TAC

The PLMN numbers indicated in Table 6.0.1-1 are used in test cases to associate a cell with an MCC and MNC for that cell. If no PLMN is explicitly specified, the default value is PLMN 1.

Table 6.0.1-1: Tracking Area Identity (TAI) in System Information Block Type 1
broadcast on the BCCH (E-UTRAN)

PLMN

MCC1

MCC2

MCC3

MNC1

MNC2

MNC3

TAC

1

0

0

1

0

1

Not present

See Table 6.0.1-2

2

0

0

2

1

1

Not present

3

0

0

3

2

1

Not present

4

0

0

4

3

1

Not present

5

0

0

5

4

1

Not present

6

0

0

6

5

1

Not present

7

0

0

7

6

1

Not present

8

0

0

8

7

1

Not present

9

0

0

9

0

2

Not present

10

0

1

0

1

2

Not present

11

0

1

1

2

2

Not present

12

0

1

2

3

2

Not present

13

0

0

2

8

1

Not present

14

0

0

2

9

1

Not present

15

0

0

1

1

1

Not present

16

0

0

1

2

1

Not present

17

0

0

1

3

1

Not present

18

0

0

1

4

1

Not present

NOTE: The Location Area Information (LAI) for UTRA and GSM could be re-used from TS 34.123-1 clause 6.

If no TAC for E-UTRAN cell is explicitly specified in the test case description, the TACs for E-UTRAN cells indicated in Table 6.0.1-2 are used in the test case.

Table 6.0.1-2: Tracking Area Code (TAC) for E-UTRAN cells

cell ID

TAC

Cell 1

1

Cell 2

2

Cell 3

3

Cell 4

4

Cell 6

6

Cell 10

10

Cell 11

11

Cell 12

12

Cell 13

13

Cell 14

14

Cell 23

23

Cell 28

28

Cell 29

29

Cell 30

30

If no RAI for UTRAN cell is explicitly specified in the test case description, the RAI for UTRAN cells indicated in Table 4.4.4-2 in [18] are used in the test case.

6.0.2 Other

6.0.2.1 Values of parameters calculated by the UE

Values of some parameters calculated by the UE, such as Srxlev, are provided in the test case description without explicitly taking into account SS signal generation and UE measurement uncertainties. These values are for information purpose only and therefore shall not be directly used to determine the UE behaviour; instead a range of values resulting from uncertainties specific for given test case conditions shall be considered.