24.1.6 V2X Sidelink Communication / Pre-configured authorisation / UE in RRC_CONNECTED on an E-UTRAN cell operating on the anchor carrier frequency provisioned for V2X configuration / Utilisation of the resources of (serving) cells/PLMNs / Transmission / RRC connection reconfiguration with/without v2x-CommTxPoolExceptional in mobilityControlInfoV2X / Handover
36.523-13GPPEvolved Universal Terrestrial Radio Access (E-UTRA) and Evolved Packet Core (EPC)Part 1: Protocol conformance specificationRelease 17TSUser Equipment (UE) conformance specification
24.1.6.1 Test Purpose (TP)
(1)
with { UE being authorized for performing V2X sidelink Communication in PLMN1 and pre-configured with anchor carrier parameters for V2X configuration and with Radio parameters for when the UE is "not served by E-UTRAN", and, UE is in RRC_CONNECTED on Cell 1/f1/PLMN1 which is operating on the anchor carrier frequency as the one pre-configured in the UE/USIM and is broadcasting SystemInformationBlockType21,and, UE having sent a SidelinkUEInformation message requesting sidelink communication transmission resources on Cell 1/f1/PLMN1 }
ensure that {
when { UE receives RRCConnectionReconfiguration message which includes mobilityControlInfo (handover) less than 1 sec after the UE transmitted the SidelinkUEInformation message, and, MAC successfully completes the random access procedure to the targeted PCell Cell 2/f1/PLMN1 }
then { UE is able to send a SidelinkUEInformation message requesting V2X sidelink communication transmission resources on Cell 2/f1/PLMN1 and transmit V2X sidelink communication using the configured resources in Cell 2/f1/PLMN1 (v2x-InterFreqInfoList is included and resources provided in v2x‑InterFreqInfoList)}
}
(2)
with { UE being authorized for performing V2X sidelink Communication in PLMN1 and pre-configured with anchor carrier parameters for V2X configuration and with Radio parameters for when the UE is "not served by E-UTRAN", and, UE is in RRC_CONNECTED on Cell 1/f1/PLMN1 which is operating on the anchor carrier frequency as the one pre-configured in the UE/USIM and is broadcasting SystemInformationBlockType21, and, UE transmitting and receiving V2X sidelink communication using the configured resources in Cell 1/f1/PLMN1 }
ensure that {
when { UE receives RRCConnectionReconfiguration message which includes mobilityControlInfo (handover), and, v2x-CommTxPoolExceptional is included in mobilityControlInfoV2X }
then { UE is able to transmit V2X sidelink communication using the resources configured by v2x-CommTxPoolExceptional included in mobilityControlInfoV2X }
(3)
with { UE being authorized for performing V2X sidelink Communication in PLMN1 and pre-configured with anchor carrier parameters for V2X configuration and with Radio parameters for when the UE is "not served by E-UTRAN", and, UE is in RRC_CONNECTED on Cell 2/f1/PLMN1 which is operating on the anchor carrier frequency as the one pre-configured in the UE/USIM and is broadcasting SystemInformationBlockType21, and, UE having successfully completed V2X Sidelink UE information procedure requesting V2X sidelink communication transmission resources and transmitting V2X sidelink communication }
ensure that {
when { UE receives RRCConnectionReconfiguration message including mobilityControlInfo, and, v2x-CommTxPoolExceptional is not included in mobilityControlInfoV2X }
then { UE does not transmit V2X sidelink communication over the PC5 before receiving configuration from the target cell }
}
24.1.6.2 Conformance requirements
References: The conformance requirements covered in the current TC are specified in: TS 36.331, clauses 5.3.5.4, 5.3.10.15a, 5.10.13.1.
[TS 36.331, clause 5.3.5.4]
If the RRCConnectionReconfiguration message includes the mobilityControlInfo and the UE is able to comply with the configuration included in this message, the UE shall:
1> stop timer T310, if running;
1> stop timer T312, if running;
1> start timer T304 with the timer value set to t304, as included in the mobilityControlInfo;
1> stop timer T370, if running;
1> if the carrierFreq is included:
2> consider the target PCell to be one on the frequency indicated by the carrierFreq with a physical cell identity indicated by the targetPhysCellId;
1> else:
2> consider the target PCell to be one on the frequency of the source PCell with a physical cell identity indicated by the targetPhysCellId;
1> start synchronising to the DL of the target PCell;
NOTE 1: The UE should perform the handover as soon as possible following the reception of the RRC message triggering the handover, which could be before confirming successful reception (HARQ and ARQ) of this message.
…
1> if the RRCConnectionReconfiguration message includes the sl-V2X-ConfigDedicated or mobilityControlInfoV2X:
2> perform the V2X sidelink communication dedicated configuration procedure as specified in 5.3.10.15a;
1> set the content of RRCConnectionReconfigurationComplete message as follows:
2> if the UE has radio link failure or handover failure information available in VarRLF-Report and if the RPLMN is included in plmn-IdentityList stored in VarRLF-Report:
3> include rlf-InfoAvailable;
…
1> submit the RRCConnectionReconfigurationComplete message to lower layers for transmission;
1> if MAC successfully completes the random access procedure; or
1> if MAC indicates the successful reception of a PDCCH transmission addressed to C-RNTI and if rach-Skip is configured:
2> stop timer T304;
2> release ul-ConfigInfo, if configured;
…
2> if SystemInformationBlockType21 is broadcast by the target PCell; and the UE transmitted a SidelinkUEInformation message indicating a change of V2X sidelink communication related parameters relevant in target PCell (i.e. change of v2x-CommRxInterestedFreqList or v2x-CommTxResourceReq) during the last 1 second preceding reception of the RRCConnectionReconfiguration message including mobilityControlInfo:
3> initiate transmission of the SidelinkUEInformation message in accordance with 5.10.2.3;
2> the procedure ends;
[TS 36.331, clause 5.3.10.15a]
The UE shall:
1> if the RRCConnectionReconfiguration message includes the sl-V2X-ConfigDedicated:
2> if commTxResources is included and set to setup:
3> use the resources indicated by commTxResources for V2X sidelink communication transmission, as specified in 5.10.13;
3> perform CBR measurement on the transmission resource pool indicated in commTxResources for V2X sidelink communication transmission, as specified in 5.5.3;
2> else if commTxResources is included and set to release:
3> release the resources allocated for V2X sidelink communication transmission previously configured by commTxResources;
2> if v2x-InterFreqInfoList is included:
3> use the synchronization configuration and resource configuration parameters for V2X sidelink communication on frequencies included in v2x-InterFreqInfoList, as specified in 5.10.13;
3> perform CBR measurement on the transmission resource pool indicated in v2x-InterFreqInfoList for V2X sidelink communication transmission, as specified in 5.5.3;
1> if the RRCConnectionReconfiguration message includes the mobilityControlInfoV2X:
2> if v2x-CommRxPool is included:
3> use the resources indicated by v2x-CommRxPool for V2X sidelink communication reception, as specified in 5.10.12;
2> if v2x-CommTxPoolExceptional is included:
3> use the resources indicated by v2x-CommTxPoolExceptional for V2X sidelink communication transmission, as specified in 5.10.13;
3> perform CBR measurement on the transmission resource pool indicated by v2x-CommTxPoolExceptional for V2X sidelink communication transmission, as specified in 5.5.3;
[TS 36.331, clause 5.10.13.1]
A UE capable of V2X sidelink communication that is configured by upper layers to transmit V2X sidelink communication and has related data to be transmitted shall:
1> if the conditions for sidelink operation as defined in 5.10.1d are met:
2> if in coverage on the frequency used for V2X sidelink communication as defined in TS 36.304 [4, 11.4]; or
2> if the frequency used to transmit V2X sidelink communication is included in v2x-InterFreqInfoList in RRCConnectionReconfiguration or in v2x-InterFreqInfoList within SystemInformationBlockType21:
3> if the UE is in RRC_CONNECTED and uses the PCell or the frequency included in v2x-InterFreqInfoList in RRCConnectionReconfiguration for V2X sidelink communication:
4> if the UE is configured, by the current PCell with commTxResources set to scheduled:
5> if T310 or T311 is running; and if the PCell at which the UE detected physical layer problems or radio link failure broadcasts SystemInformationBlockType21 including v2x-CommTxPoolExceptional in sl-V2X-ConfigCommon, or v2x-CommTxPoolExceptional is included in v2x-InterFreqInfoList for the concerned frequency in SystemInformationBlockType21 or RRCConnectionReconfiguration; or
5> if T301 is running and the cell on which the UE initiated connection re-establishment broadcasts SystemInformationBlockType21 including v2x-CommTxPoolExceptional in sl-V2X-ConfigCommon, or v2x-CommTxPoolExceptional is included in v2x-InterFreqInfoList for the concerned frequency in SystemInformationBlockType21; or
5> if T304 is running and the UE is configured with v2x-CommTxPoolExceptional included in mobilityControlInfoV2X in RRCConnectionReconfiguration or in v2x-InterFreqInfoList for the concerned frequency in RRCConnectionReconfiguration:
6> configure lower layers to transmit the sidelink control information and the corresponding data based on random selection using the pool of resources indicated by v2x-CommTxPoolExceptional as defined in TS 36.321 [6];
5> else:
6> configure lower layers to request E-UTRAN to assign transmission resources for V2X sidelink communication;
4> else if the UE is configured with v2x-commTxPoolNormalDedicated or v2x-CommTxPoolNormal in the entry of v2x-InterFreqInfoList for the concerned frequency in sl-V2X-ConfigDedicated in RRCConnectionReconfiguration and the UE is configured to transmit non-P2X related V2X sidelink communication:
5> if a result of sensing on the resources configured in v2x-CommTxPoolNormalDedicated or v2x-CommTxPoolNormal in the entry of v2x-InterFreqInfoList for the concerned frequency in RRCConnectionReconfiguration is not available in accordance with TS 36.213 [23]:
6> if v2x-CommTxPoolExceptional is included in mobilityControlInfoV2X in RRCConnectionReconfiguration (i.e., handover case); or
6> if v2x-CommTxPoolExceptional is included in the entry of v2x-InterFreqInfoList for the concerned frequency in RRCConnectionReconfiguration; or
6> if the PCell broadcasts SystemInformationBlockType21 including v2x-CommTxPoolExceptional in sl-V2X-ConfigCommon or v2x-CommTxPoolExceptional in v2x-InterFreqInfoList for the concerned frequency:
7> configure lower layers to transmit the sidelink control information and the corresponding data based on random selection using the pool of resources indicated by v2x-CommTxPoolExceptional as defined in TS 36.321 [6];
5> else:
6> configure lower layers to transmit the sidelink control information and the corresponding data based on sensing (as defined in TS 36.321 [6] and TS 36.213 [23]) using one of the resource pools indicated by v2x-commTxPoolNormalDedicated or v2x-CommTxPoolNormal in the entry of v2x-InterFreqInfoList for the concerned frequency, which is selected according to 5.10.13.2;
4> else if the UE is configured with v2x-commTxPoolNormalDedicated in sl-P2X-ConfigDedicated or p2x-CommTxPoolNormal in the entry of v2x-InterFreqInfoList for the concerned frequency in RRCConnectionReconfiguration and the UE is configured to transmit P2X related V2X sidelink communication:
5> select a resource pool according to 5.10.13.2;
5> transmit P2X related V2X sidelink communication according to 5.10.13.1a;
3> else:
4> if the cell chosen for V2X sidelink communication transmission broadcasts SystemInformationBlockType21:
5> if the UE is configured to transmit non-P2X related V2X sidelink communication, and if SystemInformationBlockType21 includes v2x-CommTxPoolNormalCommon or v2x-CommTxPoolNormal in v2x-InterFreqInfoList for the concerned frequency in sl-V2X-ConfigCommon and a result of sensing on the resources configured in v2x-CommTxPoolNormalCommon or v2x-CommTxPoolNormal in v2x-InterFreqInfoList for the concerned frequency is available in accordance with TS 36.213 [23]:
6> configure lower layers to transmit the sidelink control information and the corresponding data based on sensing (as defined in TS 36.321 [6] and TS 36.213 [23]) using one of the resource pools indicated by v2x-CommTxPoolNormalCommon or v2x-CommTxPoolNormal in v2x-InterFreqInfoList for the concerned frequency, which is selected according to 5.10.13.2;
5> if the UE is configured to transmit P2X related V2X sidelink communication, and if SystemInformationBlockType21 includes p2x-CommTxPoolNormalCommon or p2x-CommTxPoolNormal in v2x-InterFreqInfoList for the concerned frequency in sl-V2X-ConfigCommon:
6> select a resource pool from p2x-CommTxPoolNormalCommon or p2x-CommTxPoolNormal in v2x-InterFreqInfoList for the concerned frequency according to 5.10.13.2 by ignoring zoneConfig in SystemInformationBlockType21;
6> transmit P2X related V2X sidelink communication according to 5.10.13.1a;
5> else if SystemInformationBlockType21 includes v2x-CommTxPoolExceptional in sl-V2X-ConfigCommon or v2x-CommTxPoolExceptional in v2x-InterFreqInfoList for the concerned frequency:
6> from the moment the UE initiates connection establishment until receiving an RRCConnectionReconfiguration including sl-V2X-ConfigDedicated , or until receiving an RRCConnectionRelease or an RRCConnectionReject; or
6> if the UE is in RRC_IDLE and a result of sensing on the resources configured in v2x-CommTxPoolNormalCommon or v2x-CommTxPoolNormal in v2x-InterFreqInfoList for the concerned frequency in Systeminformationblocktype21 is not available in accordance with TS 36.213 [23]:
7> configure lower layers to transmit the sidelink control information and the corresponding data based on random selection (as defined in TS 36.321 [6]) using the pool of resources indicated in v2x-CommTxPoolExceptional;
2> else:
3> configure lower layers to transmit the sidelink control information and the corresponding data based on sensing (as defined in TS 36.321 [6] and TS 36.213 [23]) using one of the resource pools indicated by v2x-CommTxPoolList in SL-V2X-Preconfiguration in case of non-P2X related V2X sidelink communication, which is selected according to 5.10.13.2, or using one of the resource pools indicated by p2x-CommTxPoolList in SL-V2X-Preconfiguration in case of P2X related V2X sidelink communication, which is selected according to 5.10.13.2, and in accordance with the timing of the selected reference as defined in 5.10.8;
The UE capable of non-P2X related V2X sidelink communication that is configured by upper layers to transmit V2X sidelink communication shall perform sensing on all pools of resources which may be used for transmission of the sidelink control information and the corresponding data. The pools of resources are indicated by SL-V2X-Preconfiguration, v2x-CommTxPoolNormalCommon, v2x-CommTxPoolNormalDedicated in sl-V2X-ConfigDedicated, or v2x-CommTxPoolNormal in v2x-InterFreqInfoList for the concerned frequency, as configured above.
24.1.6.3 Test description
24.1.6.3.1 Pre-test conditions
System Simulator:
SS-NW
– 2 cells with parameters defined in Table 24.1.6.3.1-1.
NOTE: Void
Table 24.1.6.3.1-1: Cell parameters values
Cell |
Frequency |
PLMN |
1 |
f1 |
HPLMN (PLMN1) |
2 |
f1 |
PLMN1 |
Note 1: The frequency f1 shall be the anchor frequency pre-configured in the UE/USIM. Note 2: A single frequency has been chosen to allow the TC to be applicable even for UEs supporting a single band which comprises a single frequency. |
– System information combination 29 as defined in TS 36.508 [18] clause 4.4.3.1 is used in all active cells.
SS-UE
– SS-UE1. As defined in TS 36.508 [18], configured for and operating as V2X Sidelink Communication receiving device on the resources which the UE is expected to use for transmission, as defined in TS 36.508 [18] clause 6.2.3.5.
UE:
– V2X sidelink related configuration
– The UE is authorised to perform V2X Sidelink Communication.
– The UE is equipped with below information in UE or in a USIM containing default values (as per TS 36.508 [18]) except for those listed in Table 24.1.6.3.1-2.
Table 24.1.6.3.1-2: UE/ USIM configuration
USIM field |
Priority |
Value |
Access Technology Identifier |
EFUST |
Service n°119 (V2X) supported |
||
EFVST |
As per TS 36.508 [18] clause 4.9.3.4 |
||
EFV2X_CONFIG |
SL-V2X-Preconfiguration field as defined in Table 24.1.6.3.3-4 |
Preamble:
– The UE is in State Generic Radio Bearer Establishment, UE Test Mode Activated (State 3A) on Cell 1 according to TS 36.508 [18].
24.1.6.3.2 Test procedure sequence
Table 24.1.6.3.2-0 illustrates the downlink power levels and other changing parameters to be applied for the cells at various time instants of the test execution. Row marked "T0" denotes the initial conditions after preamble, while columns marked "T1" … "Tn" are to be applied subsequently. The exact instants on which these values shall be applied are described elsewhere in the present clause.
Table 24.1.6.3.2-0: Time instances of cell power level and parameter changes
Parameter |
Unit |
Cell 1 |
Cell 2 |
|
T0 |
Cell-specific RS EPRE |
dBm/15kHz |
-79 |
-95 |
T1 |
Cell-specific RS EPRE |
dBm/15kHz |
-85 |
-79 |
T2 |
Cell-specific RS EPRE |
dBm/15kHz |
-79 |
-85 |
Table 24.1.6.3.2-1: Main behaviour
St |
Procedure |
Message Sequence |
TP |
Verdict |
|
U – S |
Message |
||||
0 |
The SS configures: SS-NW – Cell 1 transmits SystemInformationBlockType21 neither including v2x-CommTxPoolNormalCommon nor v2x-CommTxPoolNormal in v2x-InterFreqInfoList (i.e. V2X sidelink communication supported by the network, no common resources provided yet). |
– |
– |
– |
– |
– |
EXCEPTION: The following events unless otherwise stated are to be observed in Cell 1. |
– |
– |
– |
– |
1 |
Close UE Test Loop with bit E0 in UE test loop mode E LB setup IE set to one (transmission mode). |
<– |
CLOSE UE TEST LOOP |
– |
– |
2 |
The UE responds with CLOSE UE TEST LOOP COMPLETE. |
–> |
CLOSE UE TEST LOOP COMPLETE |
– |
– |
3 |
UE transmit a SidelinkUEInformation message requesting resources for transmission of V2X sidelink communication in RRC_CONNECTED in the next 5 sec. |
–> |
SidelinkUEInformation |
– |
– |
4 |
SS-NW transmits a RRCConnectionReconfiguration message assigning V2X sidelink communication transmission resources for RRC_CONNECTED (v2x-InterFreqInfoList is included and resources provided in v2x-InterFreqInfoList). |
<– |
RRCConnectionReconfiguration |
– |
– |
5 |
The UE submits RRCConnectionReconfigurationComplete message to confirm acceptance of the new configuration. |
–> |
RRCConnectionReconfigurationComplete |
– |
– |
6 |
UE transmits one STCH PDCP SDU packet of V2X sidelink communication data over the PC5 interface in accordance with the resources indicated in the RRCConnectionReconfiguration. |
–> |
STCH PDCP SDU packet |
– |
– |
7 |
The SS configures: SS-NW Cell 1 and Cell 2 parameters according to the row "T1" in table 24.1.6.3.2-0 in order to simulate needs for handover. |
– |
– |
– |
– |
8 |
SS-NW transmits an RRCConnectionReconfiguration message including mobilityControlInfo (handover), and v2x-CommTxPoolExceptional is included in mobilityControlInfoV2X. NOTE: To achieve the TP this message shall be sent less than 1 sec after the message in step 3. |
<– |
RRCConnectionReconfiguration |
– |
– |
– |
EXCEPTION: The following events unless otherwise stated are to be observed in Cell 2. |
– |
– |
– |
– |
9 |
Check: Does the UE transmit in the next 60 sec one STCH PDCP SDU packet of V2X sidelink communication data over the PC5 interface in accordance with the resources indicated in v2x-CommTxPoolExceptional included in mobilityControlInfoV2X in the RRCConnectionReconfiguration? NOTE 1: The UE may send multiple packets. The reception of one of them is sufficient for achieving the Pass verdict. NOTE 2: The structure of the data is not checked and it is just considered as octetstrings by the SS. NOTE 3: If the UE does not send this STCH PDCP SDU packet at this moment, but send it after step 10 or step 11, it is also sufficient for achieving the Pass verdict. |
–> |
STCH PDCP SDU packet |
2 |
P |
10 |
The UE submits RRCConnectionReconfigurationComplete message. |
–> |
RRCConnectionReconfigurationComplete |
– |
– |
11 |
Check: Does UE transmit a SidelinkUEInformation message requesting resources for transmission of V2X sidelink communication in RRC_CONNECTED in the next 5 sec? |
–> |
SidelinkUEInformation |
1 |
P |
12 |
SS-NW transmits an RRCConnectionReconfiguration message assigning V2X sidelink communication transmission scheduled resources (v2x-InterFreqInfoList is included and resources provided in v2x-InterFreqInfoList). |
<– |
RRCConnectionReconfiguration |
– |
– |
13 |
The UE submits RRCConnectionReconfigurationComplete message to confirm acceptance of the new configuration. |
–> |
RRCConnectionReconfigurationComplete |
– |
– |
14 |
Check: Does the UE transmit in the next 60 sec one STCH PDCP SDU packet of V2X sidelink communication data over the PC5 interface in accordance with the resources indicated in the RRCConnectionReconfiguration? NOTE 1: The UE may send multiple packets. The reception of one of them is sufficient for achieving the Pass verdict. NOTE 2: The structure of the data is not checked and it is just considered as octetstrings by the SS. |
–> |
STCH PDCP SDU packet |
1 |
P |
15 |
The SS configures: SS-NW Cell 1 and Cell 2 parameters according to the row "T2" in table 24.1.6.3.2-0 in order to simulate needs for handover. |
– |
– |
– |
– |
16 |
SS-NW transmits an RRCConnectionReconfiguration message including mobilityControlInfo (handover), and v2x-CommTxPoolExceptional is not included in mobilityControlInfoV2X. |
<– |
RRCConnectionReconfiguration |
– |
– |
– |
EXCEPTION: The following events unless otherwise stated are to be observed in Cell 1. |
– |
– |
– |
– |
17 |
Check: Does the UE transmit in the next 60 sec one STCH PDCP SDU packet of V2X sidelink communication data over the PC5 interface? |
–> |
STCH PDCP SDU packet |
3 |
F |
18 |
The UE submits RRCConnectionReconfigurationComplete message. |
–> |
RRCConnectionReconfigurationComplete |
– |
– |
19 |
SS-NW transmits an RRCConnectionReconfiguration message assigning V2X sidelink communication transmission scheduled resources (v2x-InterFreqInfoList is included and resources provided in v2x-InterFreqInfoList). |
<– |
RRCConnectionReconfiguration |
– |
– |
20 |
The UE submits RRCConnectionReconfigurationComplete message to confirm acceptance of the new configuration. |
–> |
RRCConnectionReconfigurationComplete |
– |
– |
21 |
Check: Does the UE transmit in the next 60 sec one STCH PDCP SDU packet of V2X sidelink communication data over the PC5 interface in accordance with the resources scheduled by eNB. NOTE 1: The UE may send multiple packets. The reception of one of them is sufficient for achieving the Pass verdict. NOTE 2: The structure of the data is not checked and it is just considered as octetstrings by the SS. |
–> |
STCH PDCP SDU packet |
3 |
P |
22 |
The SS transmits an OPEN UE TEST LOOP message to exit the UE test loop mode. |
<– |
OPEN UE TEST LOOP |
– |
– |
23 |
The UE transmits an OPEN UE TEST LOOP COMPLETE message. |
–> |
OPEN UE TEST LOOP COMPLETE |
– |
– |
24 |
The SS transmits a DEACTIVATE TEST MODE message to de-activate UE radio bearer test mode procedure. |
<– |
DEACTIVATE TEST MODE |
– |
– |
25 |
The UE transmits a DEACTIVATE TEST MODE COMPLETE message. |
–> |
DEACTIVATE TEST MODE COMPLETE |
– |
– |
24.1.6.3.3 Specific message contents
Table 24.1.6.3.3-0: SystemInformationBlockType21 for Cell 1 (step 0, Table 24.1.6.3.2-1)
Derivation Path: 36.508 [18], table 4.4.3.3-19 |
|||
Information Element |
Value/remark |
Comment |
Condition |
SystemInformationBlockType21-r14 ::= SEQUENCE { |
|||
sl-V2X-ConfigCommon-r14 SEQUENCE { |
|||
v2x-InterFreqInfoList-r14 SEQUENCE { |
|||
SL-InterFreqInfoV2X-r14[1] SEQUENCE { |
|||
v2x-CommCarrierFreq-r14 |
f5 in TS 36.508 [18] clause 6.2.3.5 |
||
v2x-UE-ConfigList-r14 SEQUENCE (SIZE (1.. maxCellIntra)) OF SL-V2X-InterFreqUE-Config-r14 { |
1 entry |
||
SL-V2X-InterFreqUE-Config-r14[1] SEQUENCE { |
|||
v2x-CommTxPoolNormal-r14 |
Not Present |
||
} |
|||
} |
|||
} |
|||
} |
|||
} |
|||
} |
|||
Note: V2X SideLink communication supported but no resources set for transmission. |
Table 24.1.6.3.3-1: SidelinkUEInformation (V2X) (step 3 and 11, Table 24.1.6.3.2-1)
Derivation Path: 36.508 [18], table 4.6.1-21B |
|||
Information Element |
Value/remark |
Comment |
Condition |
SidelinkUEInformation-r12 ::= SEQUENCE { |
|||
criticalExtensions CHOICE { |
|||
c1 CHOICE { |
|||
sidelinkUEInformation-r12 SEQUENCE { |
|||
nonCriticalExtension SEQUENCE { |
|||
nonCriticalExtension SEQUENCE { |
|||
v2x-CommRxInterestedFreqList-r14 SEQUENCE (SIZE (1..maxFreqV2X-r14)) OF INTEGER (0..maxFreqV2X-r14) |
[f5 in TS 36.508 [18] clause 6.2.3.5] |
Configured in SIB21 |
|
v2x-CommTxResourceReq-r14 SEQUENCE (SIZE (1..maxFreqV2X-r14)) OF SEQUENCE { |
|||
carrierFreqCommTx-r14 |
[f5 in TS 36.508 [18] clause 6.2.3.5] |
Configured in SIB21 |
|
v2x-TypeTxSync-r14 |
Not checked. |
Not checked. |
|
} |
|||
v2x-DestinationInfoList-r14 SEQUENCE (SIZE (1..maxSL-Dest-r12)) OF SEQUENCE { |
Not checked. |
Not checked. |
|
SL-DestinationIdentity-r12 |
Not checked |
Not checked |
|
} |
|||
} |
|||
} |
|||
} |
|||
} |
|||
} |
|||
} |
|||
} |
Table 24.1.6.3.3-2: RRCConnectionReconfiguration (V2X) (step 4 and 19, Table 24.1.6.3.2-1)
Derivation Path: 36.508 [18], table 4.6.1-8B condition SETUP AND SCHEDULED |
Table 24.1.6.3.3-3: RRCConnectionReconfiguration (V2X) (step 8, Table 24.1.6.3.2-1)
Derivation Path: 36.508 [18], table 4.6.1-8B and Table 4.6.5-1 |
|||
Information Element |
Value/remark |
Comment |
Condition |
RRCConnectionReconfiguration ::= SEQUENCE { |
|||
criticalExtensions CHOICE { |
|||
c1 CHOICE { |
|||
rrcConnectionReconfiguration-r8 SEQUENCE { |
|||
MobilityControlInfo-HO ::= SEQUENCE { |
|||
mobilityControlInfoV2X-r14 SEQUENCE { |
HO-V2X |
||
} |
|||
} |
|||
nonCriticalExtension SEQUENCE { |
|||
nonCriticalExtension SEQUENCE { |
|||
nonCriticalExtension SEQUENCE { |
|||
nonCriticalExtension SEQUENCE { |
|||
nonCriticalExtension SEQUENCE { |
|||
nonCriticalExtension SEQUENCE { |
|||
nonCriticalExtension SEQUENCE { |
|||
sl-V2X-ConfigDedicated-r14 SEQUENCE {} |
Not present |
||
} |
|||
} |
|||
} |
|||
} |
|||
} |
|||
} |
|||
} |
|||
} |
|||
} |
|||
} |
|||
} |
Table 24.1.6.3.3-3: RRCConnectionReconfiguration (V2X) (step 16, Table 24.1.6.3.2-1)
Derivation Path: 36.508 [18], table 4.6.1-8B and Table 4.6.5-1 |
|||
Information Element |
Value/remark |
Comment |
Condition |
RRCConnectionReconfiguration ::= SEQUENCE { |
|||
criticalExtensions CHOICE { |
|||
c1 CHOICE { |
|||
rrcConnectionReconfiguration-r8 SEQUENCE { |
|||
MobilityControlInfo-HO ::= SEQUENCE { |
|||
mobilityControlInfoV2X-r14 SEQUENCE { |
HO-V2X |
||
v2x-CommTxPoolExceptional-r14 SEQUENCE {} |
Not present |
||
} |
|||
} |
|||
nonCriticalExtension SEQUENCE { |
|||
nonCriticalExtension SEQUENCE { |
|||
nonCriticalExtension SEQUENCE { |
|||
nonCriticalExtension SEQUENCE { |
|||
nonCriticalExtension SEQUENCE { |
|||
nonCriticalExtension SEQUENCE { |
|||
nonCriticalExtension SEQUENCE { |
|||
sl-V2X-ConfigDedicated-r14 SEQUENCE {} |
Not present |
||
} |
|||
} |
|||
} |
|||
} |
|||
} |
|||
} |
|||
} |
|||
} |
|||
} |
|||
} |
|||
} |
Table 24.1.6.3.3-4: RRCConnectionReconfiguration (V2X) (step12, Table 24.1.6.3.2-1)
Derivation Path: 36.508 [18], table 4.6.1-8B |
|||
Information Element |
Value/remark |
Comment |
Condition |
RRCConnectionReconfiguration ::= SEQUENCE { |
|||
criticalExtensions CHOICE { |
|||
c1 CHOICE { |
|||
rrcConnectionReconfiguration-r8 SEQUENCE { |
|||
nonCriticalExtension SEQUENCE { |
|||
nonCriticalExtension SEQUENCE { |
|||
nonCriticalExtension SEQUENCE { |
|||
nonCriticalExtension SEQUENCE { |
|||
nonCriticalExtension SEQUENCE { |
|||
nonCriticalExtension SEQUENCE { |
|||
nonCriticalExtension SEQUENCE { |
|||
sl-V2X-ConfigDedicated-r14 SEQUENCE { |
|||
commTxResources-r14 CHOICE { |
|||
setup CHOICE { |
SETUP |
||
scheduled-r14 SEQUENCE { |
SCHEDULED |
||
sl-V-RNTI-r14 |
‘1001’H |
||
} |
|||
} |
|||
} |
|||
} |
|||
} |
|||
} |
|||
} |
|||
} |
|||
} |
|||
} |
|||
} |
|||
} |
|||
} |
|||
} |
|||
} |
Table 24.1.6.3.3-5: SL-V2X-Preconfiguration
Derivation Path: 36.508 [18], table 4.10.1.1-1 |
|||
Information Element |
Value/remark |
Comment |
Condition |
SL-V2X-Preconfiguration-r14 ::= SEQUENCE { |
|||
anchorCarrierFreqList-r14 SEQUENCE (SIZE (1..maxFreq)) OF SEQUENCE { |
1 entries |
||
ARFCN-ValueEUTRA-r9[1] |
f1 in TS 36.508 [18] clause 6.2.3.1 |
||
} |
|||
} |