6.1 General

25.1423GPPBase Station (BS) conformance testing (TDD)Release 17TS

Unless otherwise stated, the requirements in clause 6 are expressed for a single transmitter antenna connector. In case of multi-carrier transmission with multiple transmitter antenna connectors or MIMO transmission, the requirements apply for each transmitter antenna connector.

A BS supporting MC-HSDPA transmits multiple carriers simultaneously on adjacent carrier frequencies.

Unless otherwise stated, all measurements shall be made at the BS antenna connector (test port A) with a full complement of transceivers for the configuration in normal operating conditions. If any external apparatus such as a TX amplifier, a filter or the combination of such devices is used, the tests according to subclauses 5.14.4 shall be performed to ensure that the requirements are met at test port B.

Figure 6.1: Transmitter test ports

6.1.1 IMB Test Models

The set-up of physical channels for IMB transmitter tests shall be according with the test models below.

6.1.1.1 IMB Test Model 1 – TM 1

This model shall apply to QPSK tests.

Table 6.0A: IMB TM 1 Active Channels

Type

Number of Channels

Time Activity

Fraction of

Power (when channel is active) (%)

Level setting (per code) ( dB)

Channelisation Code Index

P-CCPCH+SCH

1

All slots

10

-10

1

P-CPICH

1

All slots

10

-10

0

T-CPICH

1

All slots

90

-12.22

1-15

S-CCPCH Frame Type 1 (SF=256, QPSK)

1

All slots

0.5

-23

3

S-CCPCH Frame Type 2 (SF=16, QPSK)

15

Sub-frames {0,1,2,3,4}

79.5

-12.75

1-15

The Base Station output power is set according to PRAT.

6.1.1.2 IMB Test Model 2 – TM 2

This model shall apply to 16QAM tests.

Table 6.0B: IMB TM 2 Active Channels

Type

Number of Channels

Time Activity

Fraction of

Power (when channel is active) (%)

Level setting (per code) ( dB)

Channelisation Code Index

P-CCPCH+SCH

1

All slots

10

-10

1

P-CPICH

1

All slots

10

-10

0

T-CPICH

1

All slots

90

-12.22

1-15

S-CCPCH Frame Type 1 (SF=256, QPSK)

1

All slots

0.5

-23

3

S-CCPCH Frame Type 2 (SF=16, 16QAM)

15

Sub-frames {0,1,2,3,4}

79.5

-12.75

1-15

The Base Station output power is set according to PRAT.