A.9.2 Measurement Performance for UE for 1.28 Mcps TDD

25.1233GPPRelease 17Requirements for support of radio resource management (TDD)TS

A.9.2.1 P-CCPCH RSCP

A.9.2.1.1 Test Purpose and Environment

The purpose of this test is to verify that the P-CCPCH RSCP measurement accuracy is within the specified limits. This test will verify the requirements in section 9.1.1.1.

The DL DPCH shall be transmitted in timeslot 4 and the UL DPCH shall be transmitted in timeslot 2.

A.9.2.1.1.1 Intra frequency test parameters

Both P-CCPCH RSCP intra frequency absolute and relative accuracy requirements are tested by using test parameters in Table A.9.11.

Table A.9.11: P-CCPCH RSCP Intra frequency test parameters

Test 1

Parameter

Unit

Cell 1

Cell 2

Timeslot Number

0

DwPTS

0

DwPTS

UTRA RF Channel Number (NOTE 2)

Channel 1

Channel 1

PCCPCH_Ec/Ior

dB

-3

-3

DwPCH_Ec/Ior

dB

0

0

OCNS_Ec/Ior

dB

-3

-3

dB

5

2

dBm/ 1.28 MHz

-76.6

PCCPCH RSCP, Note 1

dBm

-74.6

-77.6

Io, Note 1

dBm/ 1.28 MHz

-69

Propagation condition

AWGN

Test 2

Parameter

Unit

Cell 1

Cell 2

Timeslot Number

0

DwPTS

0

DwPTS

UTRA RF Channel Number (NOTE 2)

Channel 1

Channel 1

PCCPCH_Ec/Ior

dB

-3

-3

DwPCH_Ec/Ior

dB

0

0

OCNS_Ec/Ior

dB

-3

-3

dB

9

2

dBm/ 1.28 MHz

-60.2

PCCPCH RSCP, Note 1

dBm

-54.2

-61.2

Io, Note 1

dBm/ 1.28 MHz

-50

Propagation condition

AWGN

Test 3

Parameter

Unit

Cell 1

Cell 2

Timeslot Number

0

DwPTS

0

DwPTS

UTRA RF Channel Number (NOTE 2)

Channel 1

Channel 1

PCCPCH_Ec/Ior

dB

-3

-3

DwPCH_Ec/Ior

dB

0

0

OCNS_Ec/Ior

dB

-3

-3

dB

5

3

dBm/ 1.28 MHz

-101.9

PCCPCH RSCP, Note 1

dBm

-99.9

-101.9

Io, Note 1

dBm/ 1.28 MHz

-94

Propagation condition

AWGN

NOTE 1: PCCPCH RSCP and Io levels have been calculated from other parameters for information purposes. They are not settable parameters themselves.

NOTE2: In the case of multi-frequecny network,the UTRA RF Channel Number can be set for the primary frequency in this test.

A.9.2.1.1.1A Intra-frequency with two neighbour cells test parameters

Both P-CCPCH RSCP intra-frequency absolute and relative accuracy requirements with two neighbour cells are tested by using test parameters in Table A.9.11a.

Table A.9.11a: P-CCPCH RSCP intra-frequency with two neighbour cells test parameters

Test 1

Parameter

Unit

Cell 1

Cell 2

Cell 3

Timeslot Number

 

0

DwPTS

0

DwPTS

0

DwPTS

UTRA RF Channel Number

 

Channel 1

Channel 1

Channel 1

PCCPCH_Ec/Ior

dB

–3

 

–3

 

–3

 

DwPCH_Ec/Ior

dB

 

0

 

0

 

0

OCNS_Ec/Ior

dB

–3

 

–3

 

–3

 

dB

9

3

1

dBm/1.28 MHz

–79.5

PCCPCH RSCP (Note 1)

dBm

–73.5

 

–79.5

 

–81.5

 

Io (Note 1)

dBm/1.28 MHz

–69

Initial Time Delay () (Note 2)

Chip

 1

 5

 7

Initial Frequency Shift () (Note 3)

Hz

 20

 40

 –40

Initial Phase () (Note 4)

Degree

 0

 

 

Propagation condition

 

AWGN

Test 2

Parameter

Unit

Cell 1

Cell 2

Cell 3

Timeslot Number

 

0

DwPTS

0

DwPTS

0

DwPTS

UTRA RF Channel Number

 

Channel 1

Channel 1

Channel 1

PCCPCH_Ec/Ior

dB

–3

 

–3

 

–3

 

DwPCH_Ec/Ior

dB

 

0

 

0

 

0

OCNS_Ec/Ior

dB

–3

 

–3

 

–3

 

dB

7

7

1

dBm/1.28 MHz

–60.5

PCCPCH RSCP (Note 1)

dBm

–56.5

 

–56.5

 

–62.5

 

Io (Note 1)

dBm/1.28 MHz

–50

Initial Time Delay () (Note 2)

Chip

 1

 5

 7

Initial Frequency Shift () (Note 3)

Hz

 20

 40

 –40

Initial Phase () (Note 4)

Degree

 0

 

 

Propagation condition

 

AWGN

Test 3

Parameter

Unit

Cell 1

Cell 2

Cell 3

Timeslot Number

 

0

DwPTS

0

DwPTS

0

DwPTS

UTRA RF Channel Number

 

Channel 1

Channel 1

Channel 1

PCCPCH_Ec/Ior

dB

–3

 

–3

 

–3

 

DwPCH_Ec/Ior

dB

 

0

 

0

 

0

OCNS_Ec/Ior

dB

–3

 

–3

 

–3

 

dB

3

3

3

dBm/1.28 MHz

–101.8

PCCPCH RSCP (Note 1)

dBm

–101.8

 

–101.8

 

–101.8

 

Io (Note 1)

dBm/1.28 MHz

–94

Initial Time Delay () (Note 2)

Chip

 1

 5

 7

Initial Frequency Shift () (Note 3)

Hz

 20

 40

 –40

Initial Phase () (Note 4)

Degree

 0

 

 

Propagation condition

 

AWGN

Note 1: PCCPCH RSCP and Io levels are calculated from other parameters for information purposes.

Note 2: The delay of each base station () is moving between [0chips, 2chips] around the base point, that is, the initial cell delay (). The delay variation interval is . is the current subframe delay. The definition is as follows:

Here, is the difference between the current subframe and initial subframe in the cell.

Note 3: Frequency offset () is the difference between the actual transmit frequency and the nominal frequency in the cell. is the frequency offset of the initial subframe, is the frequency offset of the current subframe, and is the frequency offset of the next subframe. The frequency offset variation interval is . The definition is as follows:

Here, is the difference between the current subframe and initial subframe in the cell.

Note 4: The cell phase () is changing continuously in the range of . is the initial phase of the cell, is the current subframe cell phase, and the phase variation interval is . The definition is as follows:

Here, is the difference between the current subframe and initial subframe in the cell.

A.9.2.1.1.2 Inter frequency test parameters

P-CCPCH RSCP inter frequency relative accuracy requirements are tested by using test parameters in Table A.9.12.

Table A.9.12: P-CCPCH RSCP Inter frequency tests parameters

Test 1

Parameter

Unit

Cell 1

Cell 2

Timeslot Number

0

DwPTS

0

DwPTS

UTRA RF Channel Number (NOTE 2)

Channel 1

Channel 2

PCCPCH_Ec/Ior

dB

-3

-3

DwPCH_Ec/Ior

dB

0

0

OCNS_Ec/Ior

dB

-3

-3

dB

5

5

dBm/ 1.28 MHz

-75.2

-75.2

PCCPCH RSCP, Note 1

dBm

-73.2

-73.2

Io, Note 1

dBm/ 1.28 MHz

-69

Propagation condition

AWGN

Test 2

Parameter

Unit

Cell 1

Cell 2

Timeslot Number

0

DwPTS

0

DwPTS

UTRA RF Channel Number (NOTE 2)

Channel 1

Channel 2

PCCPCH_Ec/Ior

dB

-3

-3

DwPCH_Ec/Ior

dB

0

0

OCNS_Ec/Ior

dB

-3

-3

dB

7

2

dBm/ 1.28 MHz

-57.8

-54.1

PCCPCH RSCP, Note 1

dBm

-53.8

-55.1

Io, Note 1

dBm/ 1.28 MHz

-50

Propagation condition

AWGN

Test 3

Parameter

Unit

Cell 1

Cell 2

Timeslot Number

0

DwPTS

0

DwPTS

UTRA RF Channel Number (NOTE 2)

Channel 1

Channel 2

PCCPCH_Ec/Ior

dB

-3

-3

DwPCH_Ec/Ior

dB

0

0

OCNS_Ec/Ior

dB

-3

-3

dB

3

0

dBm/ 1.28 MHz

-98.7

-97

PCCPCH RSCP, Note 1

dBm

-98.7

-100

Io, Note 1

dBm/ 1.28 MHz

-94

Propagation condition

AWGN

NOTE 1: PCCPCH RSCP and Io levels have been calculated from other parameters for information purposes. They are not settable parameters themselves.

NOTE2: In the case of multi-frequency network,the UTRA RF Channel Number can be set for the primary frequency in this test.

A.9.2.1.1.2A Inter-frequency absolute accuracy test parameters

P-CCPCH RSCP inter-frequency absolute accuracy requirement is tested by using test parameters in Table A.9.12a.

Table A.9.12a: P-CCPCH RSCP inter-frequency absolute accuracy test parameters

Test 1

Parameter

Unit

Cell 1

Cell 2

Timeslot Number

0

DwPTS

0

DwPTS

UTRA RF Channel Number

Channel 1

Channel 2

PCCPCH_Ec/Ior

dB

–3

–3

DwPCH_Ec/Ior

dB

0

0

OCNS_Ec/Ior

dB

–3

–3

dB

5

5

dBm/1.28 MHz

–75.2

–75.2

PCCPCH RSCP (Note 1)

dBm

–73.2

–73.2

Io (Note 1)

dBm/1.28 MHz

–69

Propagation condition

AWGN

Test 2

Parameter

Unit

Cell 1

Cell 2

Timeslot Number

0

DwPTS

0

DwPTS

UTRA RF Channel Number

Channel 1

Channel 2

PCCPCH_Ec/Ior

dB

–3

–3

DwPCH_Ec/Ior

dB

0

0

OCNS_Ec/Ior

dB

–3

–3

dB

7

2

dBm/1.28 MHz

–57.8

–54.1

PCCPCH RSCP (Note 1)

dBm

–53.8

–55.1

Io (Note 1)

dBm/1.28 MHz

–50

Propagation condition

AWGN

Test 3

Parameter

Unit

Cell 1

Cell 2

Timeslot Number

0

DwPTS

0

DwPTS

UTRA RF Channel Number

Channel 1

Channel 2

PCCPCH_Ec/Ior

dB

–3

–3

DwPCH_Ec/Ior

dB

0

0

OCNS_Ec/Ior

dB

–3

–3

dB

3

0

dBm/1.28 MHz

–98.7

–97

PCCPCH RSCP (Note 1)

dBm

–98.7

–100

Io (Note 1)

dBm/1.28 MHz

–94

Propagation condition

AWGN

Note 1: PCCPCH RSCP and Io levels are calculated from other parameters for information purposes.

A.9.2.1.1.3 Local cell absolute accuracy test parameters

P-CCPCH RSCP local cell absolute accuracy requirements are tested by using test parameters in Table A.9.12b.

Table A.9.12b: P-CCPCH RSCP local cell absolute accuracy test parameters

Test 1

Parameter

Unit

Cell 1

Timeslot Number

0

DwPTS

UTRA RF Channel Number

Channel 1

PCCPCH_Ec/Ior

dB

0

DwPCH_Ec/Ior

dB

0

dBm/1.28 MHz

–76.6

PCCPCH RSCP

dBm

–76.6

Test 2

Parameter

Unit

Cell 1

Timeslot Number

0

DwPTS

UTRA RF Channel Number

Channel 1

PCCPCH_Ec/Ior

dB

0

DwPCH_Ec/Ior

dB

0

dBm/1.28 MHz

–85

PCCPCH RSCP

dBm

–85

Test 3

Parameter

Unit

Cell 1

Timeslot Number

0

DwPTS

UTRA RF Channel Number

Channel 1

PCCPCH_Ec/Ior

dB

0

DwPCH_Ec/Ior

dB

0

dBm/1.28 MHz

–90

PCCPCH RSCP

dBm

–90

Test 4

Parameter

Unit

Cell 1

Timeslot Number

0

DwPTS

UTRA RF Channel Number

Channel 1

PCCPCH_Ec/Ior

dB

0

DwPCH_Ec/Ior

dB

0

dBm/1.28 MHz

–95

PCCPCH RSCP

dBm

–95

A.9.2.1.1.4 Local cell in white noise test parameters

P-CCPCH RSCP local cell in white noise absolute accuracy requirements are tested by using test parameters in Table A.9.12c.

Table A.9.12c: P-CCPCH RSCP local-cell in white noise test parameters

Test 1

Parameter

Unit

Cell 1

Timeslot Number

0

DwPTS

UTRA RF Channel Number

Channel 1

PCCPCH_Ec/Ior

dB

0

DwPCH_Ec/Ior

dB

0

dB

2

dBm/1.28 MHz

–76.6

PCCPCH RSCP (Note 1)

dBm

–74.6

Propagation condition

AWGN

Test 2

Parameter

Unit

Cell 1

Timeslot Number

0

DwPTS

UTRA RF Channel Number

Channel 1

PCCPCH_Ec/Ior

dB

0

DwPCH_Ec/Ior

dB

0

dB

2

dBm/1.28 MHz

–87

PCCPCH RSCP (Note 1)

dBm

–85

Propagation condition

AWGN

Test 3

Parameter

Unit

Cell 1

Timeslot Number

0

DwPTS

UTRA RF Channel Number

Channel 1

PCCPCH_Ec/Ior

dB

0

DwPCH_Ec/Ior

dB

0

dB

2

dBm/1.28 MHz

–92

PCCPCH RSCP (Note 1)

dBm

–90

Propagation condition

AWGN

Test 4

Parameter

Unit

Cell 1

Timeslot Number

0

DwPTS

UTRA RF Channel Number

Channel 1

PCCPCH_Ec/Ior

dB

0

DwPCH_Ec/Ior

dB

0

dB

2

dBm/1.28 MHz

–97

PCCPCH RSCP (Note 1)

dBm

–95

Propagation condition

AWGN

Note 1: PCCPCH RSCP and Io levels are calculated from other parameters for information purposes.

A.9.2.1.2 Test Requirements

The P-CCPCH RSCP measurement accuracy shall meet the requirements in section 9.1.1.1.

The rate of correct measurements observed during repeated tests shall be at least 90%.

A.9.2.2 CPICH measurements

A.9.2.2.1 CPICH RSCP

A.9.2.2.1.1 Test Purpose and Environment

The purpose of this test is to verify that the CPICH RSCP measurement accuracy is within the specified limits. This test will verify the requirements in section 9.1.1.2 and applies to UE’s supporting this capability.

The DL DPCH shall be transmitted in timeslot 4 and the UL DPCH shall be transmitted in timeslot 2.

A.9.2.2.1.1.1 Inter frequency test parameters

Cell 1 is a UTRA TDD cell and cell 2 is a UTRA FDD cell.

CPICH RSCP inter frequency absolute accuracy requirements are tested by using test parameters in Table A.9.13.

Table A.9.13: CPICH RSCP Inter frequency tests parameters

Parameter

Unit

Test 1

Test 2

Cell 1

Cell 2

Cell 1

Cell 2

DL timeslot number

0

DwPTS

n.a.

0

DwPTS

n.a.

UTRA RF Channel number (NOTE 3)

Channel 1

Channel 2

Channel 1

Channel 2

CPICH_Ec/Ior

dB

n.a.

-10

n.a.

-10

PCCPCH_Ec/Ior

dB

-3

-12

-3

-12

DwPCH_Ec/Ior

dB

0

n.a.

0

n.a.

SCH_Ec/Ior

dB

n.a.

-12

n.a.

-12

PICH_Ec/Ior

dB

n.a.

-15

n.a.

-15

OCNS_Ec/Ior

dB

-3

-0.94

-3

-0.94

Ioc, Note 2

dBm/ 3.84 MHz

n.a.

-60

n.a.

-84

Ioc, Note 2

dBm/ 1.28 MHz

-57.7

n.a.

-84.7

n.a.

Îor/Ioc

dB

7

9.54

3

0

PCCPCH RSCP, Note 1

dBm

-53.7

n.a.

-84.7

n.a.

CPICH RSCP, Note 1

dBm

n.a.

-60.46

n.a.

-94

Io, Notes 1, 2

dBm/3.84 MHz

n.a.

-50

n.a.

-81

Io, Notes 1, 2

dBm/1.28 MHz

-50

n.a.

-80

n.a.

Propagation condition

AWGN

AWGN

NOTE 1: PCCPCH RSCP, CPICH RSCP and Io levels have been calculated from other parameters for information purposes. They are not settable parameters themselves.

NOTE 2: Ioc and Io are given independently for TDD and FDD cells.

NOTE 3: In the case of multi-frequency network of 1.28 Mcps TDD, the UTRA RF Channel Number can be set for the primary frequency in this test.

A.9.2.2.1.2 Test Requirements

The CPICH RSCP measurement accuracy shall meet the requirements in section 9.1.1.2.

The rate of correct measurements observed during repeated tests shall be at least 90%.

A.9.2.2.2 CPICH Ec/Io

NOTE: This section is included for consistency with numbering in section 9, currently no test covering requirements in sections 9.1.1.3 exists.

A.9.2.3 Timeslot ISCP

A.9.2.3.1 Test Purpose and Environment

The purpose of this test is to verify that the Timeslot ISCP measurement accuracy is within the specified limits. This test will verify the requirements in section 9.1.1.3.

The DL DPCH shall be transmitted in timeslot 4 and the UL DPCH shall be transmitted in timeslot 2.

A.9.2.3.1.1 Intra frequency test parameters

The Timeslot ISCP intra frequency absolute accuracy requirements are tested by using test parameters in Table A.9.14.

Table A.9.14: Timeslot ISCP Intra frequency test parameters

Test 1

Parameter

Unit

Cell 1

Cell 2

Timeslot Number

0

DwPTS

0

DwPTS

UTRA RF Channel Number (NOTE 2)

Channel 1

Channel 1

PCCPCH_Ec/Ior

dB

-3

-3

DwPCH_Ec/Ior

dB

0

0

OCNS_Ec/Ior

dB

-3

-3

dB

5

2

dBm/1.28 MHz

-76.6

TS ISCP, Note 1

dBm

-74.6

-71.6

Io, Note 1

dBm/1.28 MHz

-69

Propagation condition

AWGN

Test 2

Parameter

Unit

Cell 1

Cell 2

Timeslot Number

0

DwPTS

0

DwPTS

UTRA RF Channel Number (NOTE 2)

Channel 1

Channel 1

PCCPCH_Ec/Ior

dB

-3

-3

DwPCH_Ec/Ior

dB

0

0

OCNS_Ec/Ior

dB

-3

-3

dB

9

2

dBm/1.28 MHz

-60.2

TS ISCP, Note 1

dBm

-58.2

-51.2

Io, Note 1

dBm/1.28 MHz

-50

Propagation condition

AWGN

Test 3

Parameter

Unit

Cell 1

Cell 2

Timeslot Number

0

DwPTS

0

DwPTS

UTRA RF Channel Number (NOTE 2)

Channel 1

Channel 1

PCCPCH_Ec/Ior

dB

-3

-3

DwPCH_Ec/Ior

dB

0

0

OCNS_Ec/Ior

dB

-3

-3

dB

5

3

dBm/1.28 MHz

-101.9

TS ISCP, Note 1

dBm

-98.9

-96.9

Io, Note 1

dBm/1.28 MHz

-94

Propagation condition

AWGN

NOTE 1: TS ISCP and Io levels have been calculated from other parameters for information purposes. They are not settable parameters themselves.

NOTE 2: In the case of multi-frequency network, the UTRA RF Channel Number can be set for the primary frequency in this test.

A.9.2.3.2 Test Requirements

The Timeslot ISCP measurement accuracy shall meet the requirements in section 9.1.1.3.

The rate of correct measurements observed during repeated tests shall be at least 90%.

A.9.2.4 UTRA carrier RSSI

A.9.2.4.1 Test Purpose and Environment

The purpose of this test is to verify that the UTRA Carrier RSSI measurement accuracy is within the specified limits. This test will verify the requirements in section 9.1.1.4.

The DL DPCH shall be transmitted in timeslot 4 and the UL DPCH shall be transmitted in timeslot 2.

A.9.2.4.1.1 Inter frequency test parameters

Both UTRA Carrier RSSI absolute and relative accuracy requirements are tested by using test parameters in Table A.9.15.

Table A.9.15: UTRA Carrier RSSI Inter frequency tests parameters

Test 1

Parameter

Unit

Cell 1

Cell 2

Timeslot Number

0

DwPTS

0

DwPTS

UTRA RF Channel Number (NOTE 2)

Channel 1

Channel 2

PCCPCH_Ec/Ior

dB

-3

-3

DwPCH_Ec/Ior

dB

0

0

OCNS_Ec/Ior

dB

-3

-3

dB

5

5

dBm/1.28 MHz

-75.2

-75.2

Io, Note 1

dBm/1.28 MHz

-69

Propagation condition

AWGN

Test 2

Parameter

Unit

Cell 1

Cell 2

Timeslot Number

0

DwPTS

0

DwPTS

UTRA RF Channel Number (NOTE 2)r

Channel 1

Channel 2

PCCPCH_Ec/Ior

dB

-3

-3

DwPCH_Ec/Ior

dB

0

0

OCNS_Ec/Ior

dB

-3

-3

dB

7

2

dBm/1.28 MHz

-57.8

-54.1

Io, Note 1

dBm/1.28 MHz

-50

Propagation condition

AWGN

Test 3

Parameter

Unit

Cell 1

Cell 2

Timeslot Number

0

DwPTS

0

DwPTS

UTRA RF Channel Number (NOTE 2)

Channel 1

Channel 2

PCCPCH_Ec/Ior

dB

-3

-3

DwPCH_Ec/Ior

dB

0

0

OCNS_Ec/Ior

dB

-3

-3

dB

3

0

dBm/1.28 MHz

-98.7

-97

Io, Note 1

dBm/1.28 MHz

-94

Propagation condition

AWGN

NOTE 1: Io levels have been calculated from other parameters for information purposes. They are not settable parameters themselves.

NOTE 2: In the case of multi-frequecny network,the UTRA RF Channel Number is the primary frequency’s channel number.

A.9.2.4.2 Test Requirements

The UTRA Carrier RSSI absolute and relative measurement accuracy shall meet the requirements in section 9.1.1.4.

The rate of correct measurements observed during repeated tests shall be at least 90%.

A.9.2.5 GSM carrier RSSI

A.9.2.5.1 Test Purpose and Environment

The purpose of this test is to verify that the GSM Carrier RSSI measurement accuracy is within the specified limits. This test will verify the requirements in section 9.1.1.5.

Cell 1 is a UTRA TDD cell and cell 2 is a GSM cell. In the measurement control information it is indicated to the UE that periodic reporting of the GSM carrier RSSI measurement is used.

The DL DPCH shall be transmitted in timeslot 4 and the UL DPCH shall be transmitted in timeslot 2.

A.9.2.5.1.1 Inter RAT test parameters

GSM carrier RSSI accuracy requirements are tested by using test parameters in Table A.9.16A and A.9.16B.

The limits of the GSM test parameters are defined in [21].

Table A.9.16A: General GSM Carrier RSSI test parameters

Parameter

Unit

Value

Comment

DCH parameters

DL reference measurement channel 12.2 kbps

As specified in TS 25.102 section A.2.2

Power Control

On

Target quality value on DTCH

BLER

0.01

Inter-RAT measurement quantity

GSM carrier RSSI

BSIC verification required

No

Monitored cell list size

6 GSM neighbours including ARFCN 1

Table A.9.16B: Cell 1 specific GSM Carrier RSSI test parameters

Parameter

Unit

Cell 1

DL timeslot number

0

DwPTS

UTRA RF Channel number (NOTE)

Channel 1

PCCPCH_Ec/Ior

dB

-3

DwPCH_Ec/Ior

dB

0

OCNS_Ec/Ior

dB

-3

Îor/Ioc

dB

3

Ioc

dBm / 1.28MHz

-70

Propagation condition

AWGN

NOTE: In the case of multi-frequency, the UTRA RF Channel Number can be set for the primary frequency in this test.

A.9.2.5.2 Test Requirements

The GSM Carrier RSSI measurement accuracy shall meet the requirements in section 9.1.5.

The rate of correct measurements observed during repeated tests shall be at least 90%.

A.9.2.6 SIR

NOTE: This section is included for consistency with numbering in section 9, currently no test covering requirements in sections 9.1.1.6 exists.

A.9.2.7 Transport channel BLER

NOTE: This section is included for consistency with numbering in section 9, currently no test covering requirements in sections 9.1.1.7 exists.

A.9.2.8 SFN-SFN observed time difference

A.9.2.8.1 SFN-SFN observed time difference type 1

A.9.2.8.1.1 Test Purpose and Environment

The purpose of this test is to verify that the SFN-SFN observed time difference type 1 measurement accuracy is within the specified limits. This test will verify the requirements in section 9.1.1.8.

Cell 1 and cell 2 shall be synchronised. During the test, the timing difference between cell 1 and cell 2 can be set to valid values in the range 0…3276800 chip.

The DL DPCH shall be transmitted in timeslot 4 and the UL DPCH shall be transmitted in timeslot 2.

A.9.2.8.1.1.1 Intra frequency test parameters

The SFN-SFN observed time difference type 1 accuracy requirements in the intra-frequency case are tested by using test parameters in Table A.9.17.

Table A.9.17: SFN-SFN observed time difference type 1 Intra frequency test parameters

Test 1

Parameter

Unit

Cell 1

Cell 2

Timeslot Number

0

DwPTS

0

DwPTS

UTRA RF Channel Number (NOTE 2)

Channel 1

Channel 1

PCCPCH_Ec/Ior

dB

-3

-3

DwPCH_Ec/Ior

dB

0

0

OCNS_Ec/Ior

dB

-3

-3

dB

5

2

dBm/1.28 MHz

-76.6

PCCPCH RSCP, Note 1

dBm

-74.6

-77.6

Io, Note 1

dBm/1.28 MHz

-69

Propagation condition

AWGN

Test 2

Parameter

Unit

Cell 1

Cell 2

Timeslot Number

0

DwPTS

0

DwPTS

UTRA RF Channel Number (NOTE 2)

Channel 1

Channel 1

PCCPCH_Ec/Ior

dB

-3

-3

DwPCH_Ec/Ior

dB

0

0

OCNS_Ec/Ior

dB

-3

-3

dB

9

2

dBm/1.28 MHz

-60.2

PCCPCH RSCP, Note 1

dBm

-54.2

-61.2

Io, Note 1

dBm/1.28 MHz

-50

Propagation condition

AWGN

Test 3

Parameter

Unit

Cell 1

Cell 2

Timeslot Number

0

DwPTS

0

DwPTS

UTRA RF Channel Number (NOTE 2)

Channel 1

Channel 1

PCCPCH_Ec/Ior

dB

-3

-3

DwPCH_Ec/Ior

dB

0

0

OCNS_Ec/Ior

dB

-3

-3

dB

5

3

dBm/1.28 MHz

-101.9

PCCPCH RSCP, Note 1

dBm

-99.9

-101.9

Io, Note 1

dBm/1.28 MHz

-94

Propagation condition

AWGN

NOTE 1: PCCPCH RSCP and Io levels have been calculated from other parameters for information purposes. They are not settable parameters themselves.

NOTE 2: In the case of multi-frequency network, the UTRA RF Channel Number can be set for the primary frequency in this test.

A.9.2.8.1.1.2 Inter frequency test parameters

The SFN-SFN observed time difference type 1 accuracy requirements in the inter-frequency case are tested by using test parameters in Table A.9.18.

Table A.9.18: SFN-SFN observed time difference type 1 Inter frequency tests parameters

Test 1

Parameter

Unit

Cell 1

Cell 2

Timeslot Number

0

DwPTS

0

DwPTS

UTRA RF Channel Number (NOTE 2)

Channel 1

Channel 2

PCCPCH_Ec/Ior

dB

-3

-3

DwPCH_Ec/Ior

dB

0

0

OCNS_Ec/Ior

dB

-3

-3

dB

5

5

dBm/1.28 MHz

-75.2

-75.2

PCCPCH RSCP, Note 1

dBm

-73.2

-73.2

Io, Note 1

dBm/1.28 MHz

-69

Propagation condition

AWGN

Test 2

Parameter

Unit

Cell 1

Cell 2

Timeslot Number

0

DwPTS

0

DwPTS

UTRA RF Channel Number (NOTE 2)

Channel 1

Channel 2

PCCPCH_Ec/Ior

dB

-3

-3

DwPCH_Ec/Ior

dB

0

0

OCNS_Ec/Ior

dB

-3

-3

dB

7

2

dBm/1.28 MHz

-57.8

-54.1

PCCPCH RSCP, Note 1

dBm

-53.8

-55.1

Io, Note 1

dBm/1.28 MHz

-50

Propagation condition

AWGN

Test 3

Parameter

Unit

Cell 1

Cell 2

Timeslot Number

0

DwPTS

0

DwPTS

UTRA RF Channel Number (NOTE 2)

Channel 1

Channel 2

PCCPCH_Ec/Ior

dB

-3

-3

DwPCH_Ec/Ior

dB

0

0

OCNS_Ec/Ior

dB

-3

-3

dB

3

0

dBm/1.28 MHz

-98.7

-97

PCCPCH RSCP, Note 1

dBm

-98.7

-100

Io, Note 1

dBm/1.28 MHz

-94

Propagation condition

AWGN

NOTE 1: PCCPCH RSCP and Io levels have been calculated from other parameters for information purposes. They are not settable parameters themselves.

NOTE 2: In the case of multi-frequency network,the UTRA RF Channel Number can be set for the primary frequency.

A.9.2.8.1.2 Test Requirements

The SFN-SFN observed time difference type 1 measurement accuracy shall meet the requirements in section 9.1.1.8.

The rate of correct measurements observed during repeated tests shall be at least 90%.

A.9.2.8.2 SFN-SFN observed time difference type 2

A.9.2.8.2.1 Test Purpose and Environment

The purpose of this test is to verify that the SFN-SFN observed time difference type 2 measurement accuracy is within the specified limits. This test will verify the requirements in section 9.1.1.8.

Cell 1 and cell 2 shall be synchronised and share the same frame timing. During the test, the timing difference between cell 1 and cell 2 can be set to valid values in the rang from -432 to 432 chip.

The DL DPCH shall be transmitted in timeslot 4 and the UL DPCH shall be transmitted in timeslot 2.

A.9.2.8.2.1.1 Intra frequency test parameters

The SFN-SFN observed time difference type 2 accuracy requirements in the intra-frequency case are tested by using test parameters in Table A.9.18A.

Table A.9.18A: SFN-SFN observed time difference type 2 Intra frequency test parameters

Test 1

Parameter

Unit

Cell 1

Cell 2

Timeslot Number

0

DwPTS

0

DwPTS

UTRA RF Channel Number (NOTE 2)

Channel 1

Channel 1

PCCPCH_Ec/Ior

dB

-3

-3

DwPCH_Ec/Ior

dB

0

0

OCNS_Ec/Ior

dB

-3

-3

dB

5

2

dBm/1.28 MHz

-76.6

PCCPCH RSCP, Note 1

dBm

-74.6

-77.6

Io, Note 1

dBm/1.28 MHz

-69

Propagation condition

AWGN

Test 2

Parameter

Unit

Cell 1

Cell 2

Timeslot Number

0

DwPTS

0

DwPTS

UTRA RF Channel Number (NOTE 2)

Channel 1

Channel 1

PCCPCH_Ec/Ior

dB

-3

-3

DwPCH_Ec/Ior

dB

0

0

OCNS_Ec/Ior

dB

-3

-3

dB

9

2

dBm/1.28 MHz

-60.2

PCCPCH RSCP, Note 1

dBm

-54.2

-61.2

Io, Note 1

dBm/1.28 MHz

-50

Propagation condition

AWGN

Test 3

Parameter

Unit

Cell 1

Cell 2

Timeslot Number

0

DwPTS

0

DwPTS

UTRA RF Channel Number (NOTE 2)

Channel 1

Channel 1

PCCPCH_Ec/Ior

dB

-3

-3

DwPCH_Ec/Ior

dB

0

0

OCNS_Ec/Ior

dB

-3

-3

dB

5

3

dBm/1.28 MHz

-101.9

PCCPCH RSCP, Note 1

dBm

-99.9

-101.9

Io, Note 1

dBm/1.28 MHz

-94

Propagation condition

AWGN

NOTE 1: PCCPCH RSCP and Io levels have been calculated from other parameters for information purposes. They are not settable parameters themselves.

NOTE2: In the case of multi-frequency network, the UTRA RF Channel Number can be set for the primary frequency in this test.

A.9.2.8.2.1.2 Inter frequency test parameters

The SFN-SFN observed time difference type 2 accuracy requirements in the inter-frequency case are tested by using test parameters in Table A.9.18B.

Table A.9.18B: SFN-SFN observed time difference type 2 Inter frequency tests parameters

Test 1

Parameter

Unit

Cell 1

Cell 2

Timeslot Number

0

DwPTS

0

DwPTS

UTRA RF Channel Number (NOTE 2)r

Channel 1

Channel 2

PCCPCH_Ec/Ior

dB

-3

-3

DwPCH_Ec/Ior

dB

0

0

OCNS_Ec/Ior

dB

-3

-3

dB

5

5

dBm/1.28 MHz

-75.2

-75.2

PCCPCH RSCP, Note 1

dBm

-73.2

-73.2

Io, Note 1

dBm/1.28 MHz

-69

Propagation condition

AWGN

Test 2

Parameter

Unit

Cell 1

Cell 2

Timeslot Number

0

DwPTS

0

DwPTS

UTRA RF Channel Number (NOTE 2)

Channel 1

Channel 2

PCCPCH_Ec/Ior

dB

-3

-3

DwPCH_Ec/Ior

dB

0

0

OCNS_Ec/Ior

dB

-3

-3

dB

7

2

dBm/1.28 MHz

-57.8

-54.1

PCCPCH RSCP, Note 1

dBm

-53.8

-55.1

Io, Note 1

dBm/1.28 MHz

-50

Propagation condition

AWGN

Test 3

Parameter

Unit

Cell 1

Cell 2

Timeslot Number

0

DwPTS

0

DwPTS

UTRA RF Channel Number (NOTE 2)

Channel 1

Channel 2

PCCPCH_Ec/Ior

dB

-3

-3

DwPCH_Ec/Ior

dB

0

0

OCNS_Ec/Ior

dB

-3

-3

dB

3

0

dBm/1.28 MHz

-98.7

-97

PCCPCH RSCP, Note 1

dBm

-98.7

-100

Io, Note 1

dBm/1.28 MHz

-94

Propagation condition

AWGN

NOTE 1: PCCPCH RSCP and Io levels have been calculated from other parameters for information purposes. They are not settable parameters themselves.

NOTE2: In the case of multi-frequency network, the UTRA RF Channel Number can be set for the primary frequency’s channel number.

A.9.2.8.2.2 Test Requirements

The SFN-SFN observed time difference type 2 measurement accuracy shall meet the requirements in section 9.1.1.8.

The rate of correct measurement observed during repeated tests shall be at least 90%.

A.9.2.9 Observed time difference to GSM cell

NOTE: This section is included for consistency with numbering in section 9, currently no test covering requirements in sections 9.1.1.9 exists.

A.9.2.10 SFN-CFN observed time difference

A.9.2.10.1 Test Purpose and Environment

The purpose of this test is to verify that the SFN-CFN observed time difference measurement accuracy is within the specified limits. This test will verify the requirements in section 9.1.1.10.

Cell 1 and cell 2 shall be synchronised. During the test, the timing difference between cell 1 and cell 2 can be set to any value from 0…256 frames.

The DL DPCH shall be transmitted in timeslot 4 and the UL DPCH shall be transmitted in timeslot 2.

A.9.2.10.1.1 Intra frequency test parameters

The SFN-CFN observed time difference accuracy requirements in the intra-frequency case are tested by using test parameters in Table A.9.19.

Table A.9.19: SFN-CFN observed time difference Intra frequency test parameters

Test 1

Parameter

Unit

Cell 1

Cell 2

Timeslot Number

0

DwPTS

0

DwPTS

UTRA RF Channel Number (NOTE 2)

Channel 1

Channel 1

PCCPCH_Ec/Ior

dB

-3

-3

DwPCH_Ec/Ior

dB

0

0

OCNS_Ec/Ior

dB

-3

-3

dB

5

2

dBm/1.28 MHz

-76.6

PCCPCH RSCP, Note 1

dBm

-74.6

-77.6

Io, Note 1

dBm/1.28 MHz

-69

Propagation condition

AWGN

Test 2

Parameter

Unit

Cell 1

Cell 2

Timeslot Number

0

DwPTS

0

DwPTS

UTRA RF Channel Number (NOTE 2)

Channel 1

Channel 1

PCCPCH_Ec/Ior

dB

-3

-3

DwPCH_Ec/Ior

dB

0

0

OCNS_Ec/Ior

dB

-3

-3

dB

9

2

dBm/1.28 MHz

-60.2

PCCPCH RSCP, Note 1

dBm

-54.2

-61.2

Io, Note 1

dBm/1.28 MHz

-50

Propagation condition

AWGN

Test 3

Parameter

Unit

Cell 1

Cell 2

Timeslot Number

0

DwPTS

0

DwPTS

UTRA RF Channel Number (NOTE 2)

Channel 1

Channel 1

PCCPCH_Ec/Ior

dB

-3

-3

DwPCH_Ec/Ior

dB

0

0

OCNS_Ec/Ior

dB

-3

-3

dB

5

3

dBm/1.28 MHz

-101.9

PCCPCH RSCP, Note 1

dBm

-99.9

-101.9

Io, Note 1

dBm/1.28 MHz

-94

Propagation condition

AWGN

NOTE 1: PCCPCH RSCP and Io levels have been calculated from other parameters for information purposes. They are not settable parameters themselves.

NOTE2: In the case of multi-frequency network, the UTRA RF Channel Number can be set for the primary frequency in this test.

A.9.2.10.1.2 Inter frequency test parameters

The SFN-CFN observed time difference accuracy requirements in the inter-frequency case are tested by using test parameters in Table A.9.20.

Table A.9.20: SFN-CFN observed time difference Inter frequency tests parameters

Test 1

Parameter

Unit

Cell 1

Cell 2

Timeslot Number

0

DwPTS

0

DwPTS

UTRA RF Channel Number (NOTE 2)

Channel 1

Channel 2

PCCPCH_Ec/Ior

dB

-3

-3

DwPCH_Ec/Ior

dB

0

0

OCNS_Ec/Ior

dB

-3

-3

dB

5

5

dBm/1.28 MHz

-75.2

-75.2

PCCPCH RSCP, Note 1

dBm

-73.2

-73.2

Io, Note 1

dBm/1.28 MHz

-69

Propagation condition

AWGN

Test 2

Parameter

Unit

Cell 1

Cell 2

Timeslot Number

0

DwPTS

0

DwPTS

UTRA RF Channel Number (NOTE 2)

Channel 1

Channel 2

PCCPCH_Ec/Ior

dB

-3

-3

DwPCH_Ec/Ior

dB

0

0

OCNS_Ec/Ior

dB

-3

-3

dB

7

2

dBm/1.28 MHz

-57.8

-54.1

PCCPCH RSCP, Note 1

dBm

-53.8

-55.1

Io, Note 1

dBm/1.28 MHz

-50

Propagation condition

AWGN

Test 3

Parameter

Unit

Cell 1

Cell 2

Timeslot Number

0

DwPTS

0

DwPTS

UTRA RF Channel Number (NOTE 2)

Channel 1

Channel 2

PCCPCH_Ec/Ior

dB

-3

-3

DwPCH_Ec/Ior

dB

0

0

OCNS_Ec/Ior

dB

-3

-3

dB

3

0

dBm/1.28 MHz

-98.7

-97

PCCPCH RSCP, Note 1

dBm

-98.7

-100

Io, Note 1

dBm/1.28 MHz

-94

Propagation condition

AWGN

NOTE 1: PCCPCH RSCP and Io levels have been calculated from other parameters for information purposes. They are not settable parameters themselves.

NOTE2: In the case of multi-frequency network, the UTRA RF Channel Number can be set for the primary frequency in this test.

A.9.2.10.2 Test Requirements

The SFN-CFN observed time difference measurement accuracy shall meet the requirements in section 9.1.1.10.

The rate of correct measurements observed during repeated tests shall be at least 90%.

A.9.2.11 UE transmitted power

A.9.2.11.1 Test purpose and Environment

The purpose of the test is to verify that the UE transmitted power measurement accuracy is within the specified limits. This test will verify the requirements in section 9.1.2.1.

The test parameters are given in Table A.9.21 and A.9.22 below. In the measurement control information it shall be indicated to the UE that periodic reporting of the UE transmitted power measurement shall be used.

The DL DPCH shall be transmitted in timeslot 4 and the UL DPCH shall be transmitted in timeslot 2.

Table A.9.21: General test parameters for UE transmitted power

Parameter

Unit

Value

Comment

DCH parameters

DL Reference Measurement Channel 12.2 kbps

As specified in TS 25.102 section A.2.2

Power Control

On

Target quality value on DTCH

BLER

0.01

Table A.9.22: Cell Specific parameters for UE transmitted power

Parameter

Unit

Cell 1

Timeslot Number

0

DwPTS

UTRA RF Channel Number (NOTE 2)

Channel 1

PCCPCH_Ec/Ior

dB

-3

DwPCH_Ec/Ior

dB

0

OCNS_Ec/Ior

dB

-3

dB

3

dBm/1.28MHz

-70

PCCPCH RSCP,

Note 1

dBm

-70

Propagation Condition

AWGN

NOTE 1: PCCPCH RSCP level has been calculated from other parameters for information purposes. They are not settable parameters themselves.

NOTE2: In the case of multi-frequency network, the UTRA RF Channel Number can be set for the primary frequency in this test.

A.9.2.11.1.1 Test procedure

1) Set the UE power and Maximum allowed UL TX power to the maximum power for that UE power class specified in section 9.1.2.1.

2) Send continuously Up power control commands to the UE during the entire test.

3) Check the UE reported value

4) Map the UE reported value to accuracy requirement and define the test limits

5) Measure the output power of the UE. The output power shall be averaged over one timeslot.

6) Check that the measured UE transmitted power is within the limits defined in step 4).

7) Decrease the Maximum allowed UL TX power with 1dB and signal the new value to the UE.

8) Repeat from step 3) until the entire specified range for the UE transmitted power measurement has been tested, i.e. the accuracy requirement for the UE transmitted power measurement is specified 10dB below the maximum power for the UE power class specified in section 9.1.2.1.

A.9.2.11.2 Test requirements

The UE transmitted power measurement accuracy shall meet the requirements in section 9.1.2.1.

The rate of correct measurements observed during repeated tests shall be at least 90%.