A.9.1 Measurement Performance for UE (3.84 Mcps TDD option)

25.1233GPPRelease 17Requirements for support of radio resource management (TDD)TS

A.9.1.1 P-CCPCH RSCP

A.9.1.1.1 Test Purpose and Environment

The purpose of this test is to verify that the P-CCPCH RSCP measurement accuracy is within the specified limits. This test will verify the requirements in section 9.1.1.1.

Cell 1 and cell 2 shall be synchronised, i.e. share the same frame and timeslot timing. The DL DPCH shall be transmitted in timeslot 4 and the UL DPCH shall be transmitted in timeslot 12.

A.9.1.1.1.1 Intra frequency test parameters

In this case all cells are on the same frequency. The second Beacon timeslot shall be provided in timeslot 8 for both cell 1 and cell 2.

Both P-CCPCH RSCP intra frequency absolute and relative accuracy requirements are tested by using test parameters in Table A.9.1.

Table A.9.1: P-CCPCH RSCP Intra frequency test parameters

Parameter

Unit

Test 1

Test 2

Test 3

Cell 1

Cell 2

Cell 1

Cell 2

Cell 1

Cell 2

DL timeslot number

0

0

0

0

0

0

UTRA RF Channel number

Channel 1

Channel 1

Channel 1

PCCPCH_Ec/Ior

dB

-3

-3

-3

SCH_Ec/Ior

dB

-9

-9

-9

SCH_toffset

0

5

0

5

0

5

OCNS_Ec/Ior

dB

-3,12

-3,12

-3,12

Ioc

dBm / 3.84 MHz

-75.7

-59.8

-98.7

Îor/Ioc

dB

5

2

9

2

3

0

PCCPCH RSCP, Note 1

dBm

-73.7

-76.7

-53.8

-60.8

-98.7

-101.7

Io, Note 1

dBm / 3.84 MHz

-69

-50

-94

Propagation condition

AWGN

AWGN

AWGN

NOTE 1: PCCPCH RSCP and Io levels have been calculated from other parameters for information purposes. They are not settable parameters themselves.

A.9.1.1.1.2 Inter frequency test parameters

In this case both cells are on different frequencies. The second Beacon timeslot shall be provided in timeslot 8 for cell 1 and in timeslot 10 for cell 2.

P-CCPCH RSCP inter frequency relative accuracy requirements are tested by using test parameters in Table A.9.2.

Table A.9.2: P-CCPCH RSCP Inter frequency tests parameters

Parameter

Unit

Test 1

Test 2

Test 3

Cell 1

Cell 2

Cell 1

Cell 2

Cell 1

Cell 2

DL timeslot number

0

2

0

2

0

2

UTRA RF Channel number

Channel 1

Channel 2

Channel 1

Channel 2

Channel 1

Channel 2

PCCPCH_Ec/Ior

dB

-3

-3

-3

SCH_Ec/Ior

dB

-9

-9

-9

SCH_toffset

0

5

0

5

0

5

OCNS_Ec/Ior

dB

-3,12

-3,12

-3,12

Ioc

dBm / 3.84 MHz

-75.2

-75.2

-57.8

-54.1

-98.7

-97

Îor/Ioc

dB

5

5

7

2

3

0

PCCPCH RSCP, Note 1

dBm

-73.2

-73.2

-54.8

-55.1

-98.7

-100

Io, Note 1

dBm / 3.84 MHz

-69

-50

-94

Propagation condition

AWGN

AWGN

AWGN

NOTE 1: PCCPCH RSCP and Io levels have been calculated from other parameters for information purposes. They are not settable parameters themselves.

A.9.1.1.2 Test Requirements

The P-CCPCH RSCP measurement accuracy shall meet the requirements in section 9.1.1.1.

The rate of correct measurements observed during repeated tests shall be at least 90%.

A.9.1.2 CPICH measurements

A.9.1.2.1 CPICH RSCP

A.9.1.2.1.1 Test Purpose and Environment

The purpose of this test is to verify that the CPICH RSCP measurement accuracy is within the specified limits. This test will verify the requirements in section 9.1.1.2 and applies to UE’s supporting this capability.

The DL DPCH shall be transmitted in timeslot 1 and the UL DPCH shall be transmitted in timeslot 3.

A.9.1.2.1.1.1 Inter frequency test parameters

In this case both cells are on different frequencies. Cell 1 is a UTRA TDD cell and cell 2 is a UTRA FDD cell. No second Beacon timeslot shall be provided for cell 1.

CPICH RSCP inter frequency absolute accuracy requirements are tested by using test parameters in Table A.9.3.

Table A.9.3: CPICH RSCP Inter frequency tests parameters

Parameter

Unit

Test 1

Test 2

Cell 1

Cell 2

Cell 1

Cell 2

DL timeslot number

0

n.a.

0

n.a.

UTRA RF Channel number

Channel 1

Channel 2

Channel 1

Channel 2

CPICH_Ec/Ior

dB

n.a.

-10

n.a.

-10

PCCPCH_Ec/Ior

dB

-3

-12

-3

-12

SCH_Ec/Ior

dB

-9

-12

-9

-12

SCH_toffset

5

n.a.

5

n.a.

PICH_Ec/Ior

dB

n.a.

-15

n.a.

-15

OCNS_Ec/Ior

dB

-3.12

-0.94

-3.12

-0.94

Ioc

dBm/ 3.84 MHz

-57.7

-60

-84.7

-84

Îor/Ioc

dB

7

9.54

3

0

PCCPCH RSCP, Note 1

dBm

-53.7

n.a.

-84.7

n.a.

CPICH RSCP, Note 1

dBm

n.a.

-60.46

n.a.

-94

Io, Note 1

dBm/ 3.84 MHz

-50

-50

-80

-81

Propagation condition

AWGN

AWGN

NOTE 1: PCCPCH RSCP, CPICH RSCP and Io levels have been calculated from other parameters for information purposes. They are not settable parameters themselves.

A.9.1.2.1.2 Test Requirements

The CPICH RSCP measurement accuracy shall meet the requirements in section 9.1.1.2.

The rate of correct measurements observed during repeated tests shall be at least 90%.

A.9.1.2.2 CPICH Ec/Io

NOTE: This section is included for consistency with numbering in section 9, currently no test covering requirements in sections 9.1.1.3 exists.

A.9.1.3 Timeslot ISCP

A.9.1.3.1 Test Purpose and Environment

The purpose of this test is to verify that the Timeslot ISCP measurement accuracy is within the specified limits. This test will verify the requirements in section 9.1.1.3.

Cell 1 and cell 2 shall be synchronised, i.e. share the same frame and timeslot timing. The DL DPCH shall be transmitted in timeslot 4 and the UL DPCH shall be transmitted in timeslot 12.

A.9.1.3.1.1 Intra frequency test parameters

In this case all cells are on the same frequency. The second Beacon timeslot shall be provided in timeslot 8 for both cell 1 and cell 2.

The Timeslot ISCP intra frequency absolute accuracy requirements are tested by using test parameters in Table A.9.4.

Table A.9.4: Timeslot ISCP Intra frequency test parameters

Parameter

Unit

Test 1

Test 2

Test 3

Cell 1

Cell 2

Cell 1

Cell 2

Cell 1

Cell 2

DL timeslot number

0

0

0

0

0

0

UTRA RF Channel number

Channel 1

Channel 1

Channel 1

PCCPCH_Ec/Ior

dB

-3

-3

-3

SCH_Ec/Ior

dB

-9

-9

-9

SCH_toffset

0

5

0

5

0

5

OCNS_Ec/Ior

dB

-3,12

-3,12

-3,12

Ioc

dBm / 3.84 MHz

-75.7

-59.8

-98.7

Îor/Ioc

dB

5

2

9

2

3

0

Timeslot ISCP, Note 1

dBm

-73.7

-70.7

-57.8

-50.8

-98.7

-95.7

Io, Note 1

dBm / 3.84 MHz

-69

-50

-94

Propagation condition

AWGN

AWGN

AWGN

NOTE 1: Timeslot ISCP and Io levels have been calculated from other parameters for information purposes. They are not settable parameters themselves.

A.9.1.3.2 Test Requirements

The Timeslot ISCP measurement accuracy shall meet the requirements in section 9.1.1.3.

The rate of correct measurements observed during repeated tests shall be at least 90%.

A.9.1.4 UTRA Carrier RSSI

A.9.1.4.1 Test Purpose and Environment

The purpose of this test is to verify that the UTRA Carrier RSSI measurement accuracy is within the specified limits. This test will verify the requirements in section 9.1.1.4.

Cell 1 and cell 2 shall be synchronised, i.e. share the same frame and timeslot timing. The DL DPCH shall be transmitted in timeslot 4 and the UL DPCH shall be transmitted in timeslot 12.

A.9.1.4.1.1 Inter frequency test parameters

In this case both cells are on different frequencies. The second Beacon timeslot shall be provided in timeslot 8 for cell 1 and in timeslot 10 for cell 2.

Both UTRA Carrier RSSI absolute and relative accuracy requirements are tested by using test parameters in Table A.9.5.

Table A.9.5: UTRA Carrier RSSI Inter frequency tests parameters

Parameter

Unit

Test 1

Test 2

Test 3

Cell 1

Cell 2

Cell 1

Cell 2

Cell 1

Cell 2

DL timeslot number

0

2

0

2

0

2

UTRA RF Channel number

Channel 1

Channel 2

Channel 1

Channel 2

Channel 1

Channel 2

PCCPCH_Ec/Ior

dB

-3

-3

-3

SCH_Ec/Ior

dB

-9

-9

-9

SCH_toffset

0

5

0

5

0

5

OCNS_Ec/Ior

dB

-3,12

-3,12

-3,12

Ioc

dBm / 3.84 MHz

-75.2

-75.2

-57.8

-54.1

-98.7

-97

Îor/Ioc

dB

5

5

7

2

3

0

Io, Note 1

dBm / 3.84 MHz

-69

-50

-94

Propagation condition

AWGN

AWGN

AWGN

NOTE 1: Io levels have been calculated from other parameters for information purposes. They are not settable parameters themselves.

A.9.1.4.2 Test Requirements

The UTRA Carrier RSSI absolute measurement accuracy shall meet the requirements in section 9.1.1.4.

The UTRA Carrier RSSI relative measurement accuracy shall meet the requirements in Table A.9.6 by taking into account the effect of thermal noise and noise added by the receiver.

Table A.9.6: UTRA Carrier RSSI relative accuracy

Parameter

Unit

Accuracy [dB]

Conditions

Normal condition

Extreme condition

Io [dBm/3.84 MHz]

UTRA Carrier RSSI

dBm

-4…5.2

-7…8.2

-94…-87

dBm

± 4

± 7

-87…-70

dBm

± 6

± 9

-70…-50

The rate of correct measurements observed during repeated tests shall be at least 90%.

A.9.1.5 GSM carrier RSSI

A.9.1.5.1 Test Purpose and Environment

The purpose of this test is to verify that the GSM Carrier RSSI measurement accuracy is within the specified limits. This test will verify the requirements in section 9.1.5.

Cell 1 is a UTRA TDD cell and cell 2 is a GSM cell. The Beacon timeslot shall be provided in timeslot 0 and no second Beacon timeslot shall be provided for cell 1. In the measurement control information it is indicated to the UE that periodic reporting of the GSM carrier RSSI measurement is used. The DL DPCH shall be transmitted in timeslot 1 and the UL DPCH shall be transmitted in timeslot 3.

A.9.1.5.1.1 Inter frequency test parameters

GSM carrier RSSI accuracy requirements are tested by using test parameters in Table A.9.6A and A.9.6B.

The limits of the GSM test parameters are defined in [21].

Table A.9.6A: General GSM Carrier RSSI test parameters

Parameter

Unit

Value

Comment

DCH parameters

DL reference measurement channel 12.2 kbps

As specified in TS 25.102 section A.2.2

Power Control

On

Target quality value on DTCH

BLER

0.01

Inter-RAT measurement quantity

GSM carrier RSSI

BSIC verification required

No

Monitored cell list size

6 GSM neighbours including ARFCN 1

Table A.9.6B: Cell 1 specific GSM Carrier RSSI test parameters

Parameter

Unit

Cell 1

DL timeslot number

0

1

UTRA RF Channel number

Channel 1

PCCPCH_Ec/Ior

dB

-3

n.a.

SCH_Ec/Ior

dB

-9

n.a.

SCH_toffset

0

n.a.

OCNS_Ec/Ior

dB

-3,12

Note 2

DPCH_Ec/Ior

dB

n.a.

Note 1

Îor/Ioc

dB

6

6

Io, Note 1

dBm / 3.84 MHz

-70

Propagation condition

AWGN

Note 1: The DPCH level is controlled by the power control loop

Note 2: The power of the OCNS channel that is added shall make the total power from the cell to be equal to Ior.

A.9.1.5.2 Test Requirements

The GSM Carrier RSSI measurement accuracy shall meet the requirements in section 9.1.5.

The rate of correct measurements observed during repeated tests shall be at least 90%.

A.9.1.6 SIR

NOTE: This section is included for consistency with numbering in section 9, currently no test covering requirements in sections 9.1.1.6 exists.

A.9.1.7 Transport channel BLER

NOTE: This section is included for consistency with numbering in section 9, currently no test covering requirements in sections 9.1.1.7 exists.

A.9.1.8 SFN-SFN observed time difference

A.9.1.8.1 SFN-SFN observed time difference type 1

A.9.1.8.1.1 Test Purpose and Environment

The purpose of this test is to verify that the SFN-SFN observed time difference type 1 measurement accuracy is within the specified limits. This test will verify the requirements in section 9.1.1.8.

Cell 1 and cell 2 shall be synchronised, i.e. share the same frame and timeslot timing. During the test, the timing difference between cell 1 and cell 2 can be set to any value from 0…9830400 chip.

The DL DPCH shall be transmitted in timeslot 4 and the UL DPCH shall be transmitted in timeslot 12. The second Beacon timeslot shall be provided in timeslot 8 for cell 1 and in timeslot 10 for cell 2.

A.9.1.8.1.1.1 Intra frequency test parameters

In this case all cells are on the same frequency. The SFN-SFN observed time difference type 1 accuracy requirements in the intra-frequency case are tested by using test parameters in Table A.9.7.

Table A.9.7: SFN-SFN observed time difference type 1 Intra frequency test parameters

Parameter

Unit

Test 1

Test 2

Test 3

Cell 1

Cell 2

Cell 1

Cell 2

Cell 1

Cell 2

DL timeslot number

0

2

0

2

0

2

UTRA RF Channel number

Channel 1

Channel 1

Channel 1

PCCPCH_Ec/Ior

dB

-3

-3

-3

SCH_Ec/Ior

dB

-9

-9

-9

SCH_toffset

0

5

0

5

0

5

OCNS_Ec/Ior

dB

-3,12

-3,12

-3,12

Ioc

dBm / 3.84 MHz

-75.2

-75.2

-57.8

-54.7

-98.7

-98.7

Îor/Ioc

dB

5

5

7

3

3

3

Io, Note 1

dBm / 3.84 MHz

-69

-50

-94

Propagation condition

AWGN

AWGN

AWGN

NOTE 1: Io levels have been calculated from other parameters for information purposes. They are not settable parameters themselves.

A.9.1.8.1.1.2 Inter frequency test parameters

In this case both cells are on different frequencies. The SFN-SFN observed time difference type 2 accuracy requirements in the inter-frequency case are tested by using test parameters in Table A.9.8.

Table A.9.8: SFN-SFN observed time difference type 1 Inter frequency tests parameters

Parameter

Unit

Test 1

Test 2

Test 3

Cell 1

Cell 2

Cell 1

Cell 2

Cell 1

Cell 2

DL timeslot number

0

2

0

2

0

2

UTRA RF Channel number

Channel 1

Channel 2

Channel 1

Channel 2

Channel 1

Channel 2

PCCPCH_Ec/Ior

dB

-3

-3

-3

SCH_Ec/Ior

dB

-9

-9

-9

SCH_toffset

0

5

0

5

0

5

OCNS_Ec/Ior

dB

-3,12

-3,12

-3,12

Ioc

dBm / 3.84 MHz

-75.2

-75.2

-57.8

-54.7

-98.7

-98.7

Îor/Ioc

dB

5

5

7

3

3

3

Io, Note 1

dBm / 3.84 MHz

-69

-50

-94

Propagation condition

AWGN

AWGN

AWGN

NOTE 1: Io levels have been calculated from other parameters for information purposes. They are not settable parameters themselves.

A.9.1.8.1.2 Test Requirements

The SFN-SFN observed time difference type 1 measurement accuracy shall meet the requirements in section 9.1.1.8.

The rate of correct measurements observed during repeated tests shall be at least 90%.

A.9.1.8.2 SFN-SFN observed time difference type 2

A.9.1.8.2.1 Test Purpose and Environment

The purpose of this test is to verify that the SFN-SFN observed time difference type 2 measurement accuracy is within the specified limits. This test will verify the requirements in section 9.1.1.8.

Cell 1 and cell 2 shall be synchronised, i.e. share the same frame and timeslot timing. During the test, the timing difference between cell 1 and cell 2 can be set to any value from -1280 … +1280 chip.

The DL DPCH shall be transmitted in timeslot 4 and the UL DPCH shall be transmitted in timeslot 12. The second Beacon timeslot shall be provided in timeslot 8 for cell 1 and in timeslot 10 for cell 2.

A.9.1.8.2.1.1 Intra frequency test parameters

In this case all cells are on the same frequency. The SFN-SFN observed time difference type 2 accuracy requirements in the intra-frequency case are tested by using test parameters in Table A.9.8A.

Table A.9.8A: SFN-SFN observed time difference type 2 Intra frequency test parameters

Parameter

Unit

Test 1

Test 2

Test 3

Cell 1

Cell 2

Cell 1

Cell 2

Cell 1

Cell 2

DL timeslot number

0

2

0

2

0

2

UTRA RF Channel number

Channel 1

Channel 1

Channel 1

PCCPCH_Ec/Ior

dB

-3

-3

-3

SCH_Ec/Ior

dB

-9

-9

-9

SCH_toffset

0

5

0

5

0

5

OCNS_Ec/Ior

dB

-3,12

-3,12

-3,12

Ioc

dBm / 3.84 MHz

-75.2

-75.2

-57.8

-54.7

-98.7

-98.7

Îor/Ioc

dB

5

5

7

3

3

3

Io, Note 1

dBm / 3.84 MHz

-69

-50

-94

Propagation condition

AWGN

AWGN

AWGN

NOTE 1: Io levels have been calculated from other parameters for information purposes. They are not settable parameters themselves.

A.9.1.8.2.1.2 Inter frequency test parameters

In this case both cells are on different frequencies. The SFN-SFN observed time difference type 2 accuracy requirements in the inter-frequency case are tested by using test parameters in Table A.9.8B.

Table A.9.8B: SFN-SFN observed time difference type 2 Inter frequency tests parameters

Parameter

Unit

Test 1

Test 2

Test 3

Cell 1

Cell 2

Cell 1

Cell 2

Cell 1

Cell 2

DL timeslot number

0

2

0

2

0

2

UTRA RF Channel number

Channel 1

Channel 2

Channel 1

Channel 2

Channel 1

Channel 2

PCCPCH_Ec/Ior

dB

-3

-3

-3

SCH_Ec/Ior

dB

-9

-9

-9

SCH_toffset

0

5

0

5

0

5

OCNS_Ec/Ior

dB

-3,12

-3,12

-3,12

Ioc

dBm / 3.84 MHz

-75.2

-75.2

-57.8

-54.7

-98.7

-98.7

Îor/Ioc

dB

5

5

7

3

3

3

Io, Note 1

dBm / 3.84 MHz

-69

-50

-94

Propagation condition

AWGN

AWGN

AWGN

NOTE 1: Io levels have been calculated from other parameters for information purposes. They are not settable parameters themselves.

A.9.1.8.2.2 Test Requirements

The SFN-SFN observed time difference type 2 measurement accuracy shall meet the requirements in section 9.1.1.8.

The rate of correct measurements observed during repeated tests shall be at least 90%.

A.9.1.9 Observed time difference to GSM cell

NOTE: This section is included for consistency with numbering in section 9, currently no test covering requirements in sections 9.1.1.9 exists.

A.9.1.10 SFN-CFN observed time difference

A.9.1.10.1 Test Purpose and Environment

The purpose of this test is to verify that the SFN-CFN observed time difference measurement accuracy is within the specified limits. This test will verify the requirements in section 9.1.1.10.

Cell 1 and cell 2 shall be synchronised, i.e. share the same frame and timeslot timing. During the test, the timing difference between cell 1 and cell 2 can be set to any value from 0…256 frames.

The DL DPCH shall be transmitted in timeslot 4 and the UL DPCH shall be transmitted in timeslot 12. The second Beacon timeslot shall be provided in timeslot 8 for cell 1 and in timeslot 10 for cell 2.

A.9.1.10.1.1 Intra frequency test parameters

In this case all cells are on the same frequency. The SFN-CFN observed time difference accuracy requirements in the intra-frequency case are tested by using test parameters in Table A.9.9.

Table A.9.9: SFN-CFN observed time difference Intra frequency test parameters

Parameter

Unit

Test 1

Test 2

Test 3

Cell 1

Cell 2

Cell 1

Cell 2

Cell 1

Cell 2

DL timeslot number

0

2

0

2

0

2

UTRA RF Channel number

Channel 1

Channel 1

Channel 1

PCCPCH_Ec/Ior

dB

-3

-3

-3

SCH_Ec/Ior

dB

-9

-9

-9

SCH_toffset

0

5

0

5

0

5

OCNS_Ec/Ior

dB

-3,12

-3,12

-3,12

Ioc

dBm / 3.84 MHz

-75.2

-75.2

-57.8

-54.7

-98.7

-98.7

Îor/Ioc

dB

5

5

7

3

3

3

Io, Note 1

dBm / 3.84 MHz

-69

-50

-94

Propagation condition

AWGN

AWGN

AWGN

NOTE 1: Io levels have been calculated from other parameters for information purposes. They are not settable parameters themselves.

A.9.1.10.1.2 Inter frequency test parameters

In this case both cells are on different frequencies. The SFN-CFN observed time difference accuracy requirements in the inter-frequency case are tested by using test parameters in Table A.9.10.

Table A.9.10: SFN-CFN observed time difference Inter frequency tests parameters

Parameter

Unit

Test 1

Test 2

Test 3

Cell 1

Cell 2

Cell 1

Cell 2

Cell 1

Cell 2

DL timeslot number

0

2

0

2

0

2

UTRA RF Channel number

Channel 1

Channel 2

Channel 1

Channel 2

Channel 1

Channel 2

PCCPCH_Ec/Ior

dB

-3

-3

-3

SCH_Ec/Ior

dB

-9

-9

-9

SCH_toffset

0

5

0

5

0

5

OCNS_Ec/Ior

dB

-3,12

-3,12

-3,12

Ioc

dBm / 3.84 MHz

-75.2

-75.2

-57.8

-54.7

-98.7

-98.7

Îor/Ioc

dB

5

5

7

3

3

3

Io, Note 1

dBm / 3.84 MHz

-69

-50

-94

Propagation condition

AWGN

AWGN

AWGN

NOTE 1: Io levels have been calculated from other parameters for information purposes. They are not settable parameters themselves.

A.9.1.10.2 Test Requirements

The SFN-CFN observed time difference measurement accuracy shall meet the requirements in section 9.1.1.10.

The rate of correct measurements observed during repeated tests shall be at least 90%.

A.9.1.11 UE transmitted power

NOTE: This section is included for consistency with numbering in section 9, currently no test covering requirements in sections 9.1.1.11 exists.