9.1 General

24.2823GPPMission Critical Data (MCData) signalling controlProtocol specificationRelease 18TS

The group administrator can disable the SDS service on a MCData group by setting the <mcdata-allow-short-data-service> element under the <list-service> element, in the group document, to "false".

If the <mcdata-allow-short-data-service> element under the <list-service> element, in the group document, is set to "false" for a MCData group:

– an MCData client should not use the procedures in the clauses of the parent clause to send SDS to the said MCData group.

– a terminating MCData controlling function should reject the request to send SDS to the said MCData group.