5.9 Activation/Deactivation of SCells
38.3213GPPMedium Access Control (MAC) protocol specificationNRRelease 17TS
If the MAC entity is configured with one or more SCells, the network may activate and deactivate the configured SCells. Upon configuration of an SCell, the SCell is deactivated unless the parameter sCellState is set to activated for the SCell by upper layers.
The configured SCell(s) is activated and deactivated by:
– receiving the SCell Activation/Deactivation MAC CE described in clause 6.1.3.10;
– receiving the Enhanced SCell Activation/Deactivation MAC CE described in clause 6.1.3.55;
– configuring sCellDeactivationTimer timer per configured SCell (except the SCell configured with PUCCH, if any): the associated SCell is deactivated upon its expiry;
– configuring sCellState per configured SCell: if configured, the associated SCell is activated upon SCell configuration;
– receiving scg-State: the SCells of SCG are deactivated.
The MAC entity shall for each configured SCell:
1> if an SCell is configured with sCellState set to activated upon SCell configuration, or an SCell Activation/Deactivation MAC CE or an Enhanced SCell Activation/Deactivation MAC CE is received activating the SCell:
2> if the SCell was deactivated prior to receiving this Enhanced SCell Activation/Deactivation MAC CE and a TRS is indicated for this SCell:
3> indicate to lower layers the information regarding the TRS.
2> if the SCell was deactivated prior to receiving this SCell Activation/Deactivation MAC CE or this Enhanced SCell Activation/Deactivation MAC CE; or
2> if the SCell is configured with sCellState set to activated upon SCell configuration:
3> if firstActiveDownlinkBWP-Id is not set to dormant BWP:
4> activate the SCell according to the timing defined in TS 38.213 [6] for MAC CE activation and according to the timing defined in TS 38.133 [11] for direct SCell activation; i.e. apply normal SCell operation including:
5> SRS transmissions on the SCell;
5> CSI reporting for the SCell;
5> PDCCH monitoring on the SCell;
5> PDCCH monitoring for the SCell;
5> PUCCH transmissions on the SCell, if configured.
3> else (i.e. firstActiveDownlinkBWP-Id is set to dormant BWP):
4> stop the bwp-InactivityTimer of this Serving Cell, if running.
3> activate the DL BWP and UL BWP indicated by firstActiveDownlinkBWP-Id and firstActiveUplinkBWP-Id respectively.
2> start or restart the sCellDeactivationTimer associated with the SCell according to the timing defined in TS 38.213 [6] for MAC CE activation and according to the timing defined in TS 38.133 [11] for direct SCell activation;
2> if the active DL BWP is not the dormant BWP:
3> (re-)initialize any suspended configured uplink grants of configured grant Type 1 associated with this SCell according to the stored configuration, if any, and to start in the symbol according to rules in clause 5.8.2;
3> trigger PHR according to clause 5.4.6.
1> else if an SCell Activation/Deactivation MAC CE or an Enhanced SCell Activation/Deactivation MAC CE is received deactivating the SCell; or
1> if the sCellDeactivationTimer associated with the activated SCell expires; or
1> if the SCG associated with the activated SCell is deactivated:
2> deactivate the SCell according to the timing defined in TS 38.213 [6];
2> stop the sCellDeactivationTimer associated with the SCell;
2> stop the bwp-InactivityTimer associated with the SCell;
2> deactivate any active BWP associated with the SCell;
2> clear any configured downlink assignment and any configured uplink grant Type 2 associated with the SCell respectively;
2> clear any PUSCH resource for semi-persistent CSI reporting associated with the SCell;
2> suspend any configured uplink grant Type 1 associated with the SCell;
2> flush all HARQ buffers associated with the SCell;
2> cancel, if any, triggered consistent LBT failure for the SCell.
1> if PDCCH on the activated SCell indicates an uplink grant or downlink assignment; or
1> if PDCCH on the Serving Cell scheduling the activated SCell indicates an uplink grant or a downlink assignment for the activated SCell; or
1> if a MAC PDU is transmitted in a configured uplink grant and LBT failure indication is not received from lower layers; or
1> if a MAC PDU is received in a configured downlink assignment:
2> restart the sCellDeactivationTimer associated with the SCell.
1> if the SCell is deactivated:
2> not transmit SRS on the SCell;
2> not report CSI for the SCell;
2> not transmit on UL-SCH on the SCell;
2> not transmit on RACH on the SCell;
2> not monitor the PDCCH on the SCell;
2> not monitor the PDCCH for the SCell;
2> not transmit PUCCH on the SCell.
HARQ feedback for the MAC PDU containing SCell Activation/Deactivation MAC CE or Enhanced SCell Activation/Deactivation MAC CE shall not be impacted by PCell, PSCell and PUCCH SCell interruptions due to SCell activation/deactivation in TS 38.133 [11].
When SCell is deactivated, the ongoing Random Access procedure on the SCell, if any, is aborted.