D.3.6 FR2 Power validation
38.1513GPPNRRelease 17TSUser Equipment (UE) Multiple Input Multiple Output (MIMO) Over-the-Air (OTA) performance requirements
This measurement checks the total power in the centre of the test zone. The power validation is measured with a spectrum analyser as shown in Figure D.3.6-1.
Figure D.3.6-1: Setup for FR2 power validation measurements
Spectrum analyser settings:
Table D.3.6-1: Spectrum analyser settings for FR2 power validation measurements
Item |
Unit |
Value |
---|---|---|
Centre frequency |
MHz |
Downlink centre frequency in Table D.3.1-1 |
Integrated Channel Span |
Hz |
20MHz |
RBW |
Hz |
30 kHz |
VBW |
Hz |
≥10MHz |
Number of points |
≥400 |
|
Averaging |
≥100 |
|
Detector |
RMS |
Measurement Procedure:
1. Place a horn antenna with H polarization terminated in the centre of the test zone connected to a spectrum analyser (or power meter) via a cable.
2. Record the cable and horn antenna gains.
3. Load the target channel model into the channel emulator.
4. Start the NR FR2 signalling in the base station emulator with the required parameter identical to the measurements conditions.
5. Average the power received by the spectrum analyser for a sufficient amount of time to account for the fading channel – one full channel simulation might be unnecessary.
6. Repeat steps 1 to 4 with a horn antenna V polarization terminated for the horizontal polarization, in four orthogonal horizontal positions and summed to measure the H component.
7. Calculate the total power received at the test area as the sum of the power in the two polarizations.