D.3.2 FR2 Power Delay Profile (PDP)

38.1513GPPNRRelease 17TSUser Equipment (UE) Multiple Input Multiple Output (MIMO) Over-the-Air (OTA) performance requirements

This measurement checks that the resulting power delay profile (PDP) is in-line with the PDP defined for the channel model. For PDP validation measurement, only Vertical validation is required.

The PDP measurement is performed with a Vector Network Analyser (VNA). An example setup for PDP measurement is shown in Figure D.3.2-1. VNA transmits frequency sweep signals thorough the NR MIMO OTA test system. A reference antenna, within the centre of the test zone, receives the signal and VNA analyses the frequency response of the system. A number of traces (frequency responses) are measured and recorded by VNA and analysed by a post processing SW, e.g., Matlab. Special care has to be taken into account to keep the fading conditions unchanged, i.e. frozen, during the short period of time of a single trace measurement. The fading may proceed only in between traces.

Figure D.3.2-1: Setup for PDP measurements (FR2)

Step the emulation and store traces from VNA. I.e. run the emulation to CIR number 1, pause, measure VNA trace, run the emulation to CIR number 10, pause, measure VNA trace. Continue until 1000 VNA traces are measured.

VNA settings:

Table D.3.2-1: VNA settings for FR2 PDP measurements

Item

Unit

Value

Centre frequency

MHz

Downlink centre frequency

in Table D.3.1-1

Span

MHz

200

Number of traces

1000

Number of points

1101

Averaging

1

Channel model specification:

Table D.3.2-2: Channel model specification for FR2 PDP measurements

Item

Unit

Value

Centre frequency

MHz

Downlink centre frequency

in Table D.3.1-1

Distance between traces in channel model

wavelength (Note)

> 2

Channel model

As specified in Annex D.1

NOTE: Time [s] = distance [λ] / MS speed [λ/s]

MS speed [λ/s] = MS speed [m/s] / Speed of light [m/s] * Centre frequency [Hz]

Method of measurement result analysis:

Measured VNA traces (frequency responses H(t,f)) are saved into a hard drive. The data is read into, e.g., Matlab.
The analysis is performed by taking the Fourier transform of each trace. The resulting impulse responses h(t,) are averaged in power over time:

Finally, the resulting PDP is shifted in delay, such that the first tap is on delay zero.

The detailed PDP reference value for FR2 CDL-C UMi validation are defined in the following table:

Table D.3.2-3: PDP Targets for FR2 CDL-C UMi

Combined Clusters index

Delay(ns)

Power(dB)

1-5

15

-17.9

6-11

40

0.0

13-14

75

-31.2