D.3.1 General
38.1513GPPNRRelease 17TSUser Equipment (UE) Multiple Input Multiple Output (MIMO) Over-the-Air (OTA) performance requirements
This clause describes the FR2 MIMO OTA validation measurements, in order to ensure that the channel models are correctly implemented and hence capable of generating the propagation environment, as described by the model, within the test zone of the 3D-MPAC system.
The following measurements shall be done for FR2 channel model validation:
Power Delay Profile (PDP)
Doppler/Temporal correlation
PAS similarity percentage (PSP)
Cross-polarization
Power validation
Frequencies to be used to test for FR2 channel model validation:
Table D.3.1-1: FR2 Channel model validation frequencies
NR FR2 Bands |
Range |
Test Frequency (MHz) |
n257 |
Low |
27750 |
n260 |
High |
38500 |
n258 |
Low |
25875 |
n261 |
Low |
27925 |