C.4.2 Pass/Fail Criteria of PDP

38.1513GPPNRRelease 17TSUser Equipment (UE) Multiple Input Multiple Output (MIMO) Over-the-Air (OTA) performance requirements

This clause defines the pass/fail criteria of PDP, this pass/fail limits apply for all FR1 frequency bands, for both combined and individual beams.

The detailed pass/fail limits for each cluster of CDL-C UMa and CDL-C UMi are defined in Table C.4.2-1.

Table C.4.2-1: PDP pass/fail limits for CDL-C UMa and CDL-C UMi channel model validation

Power Tolerance

Delay Tolerance

Paths from 0dB to 10dB

±1dB

±6ns

Paths from 10dB to 20dB

±2.5dB

±6ns

Paths from 20dB to 30dB

±5dB

±6ns

Paths from 30dB to 40dB

±10dB

±6ns