B.2.5 Preliminary MU of FR2 3D-MPAC system

38.1513GPPNRRelease 17TSUser Equipment (UE) Multiple Input Multiple Output (MIMO) Over-the-Air (OTA) performance requirements

This clause defines the Preliminary measurement uncertainty (MU) budget for FR2 3D-MPAC system, as shown in Table A.2.5-1.

Table B.2.5-1: Preliminary measurement uncertainty budget for FR2 3D-MPAC systemUID

Description of uncertainty contribution

Example value (26.5GHz≤f≤29.5GHz)

Example value (37GHz ≤f≤40GHz)

Distribution of the probability

Std Uncertainty (26.5GHz≤f≤29.5GHz) [dB]

Std Uncertainty (37GHz ≤f≤40GHz) [dB]

Stage 2: DUT measurement

1

Mismatch for measurement process

[1.30]

TBD

[Actual]

[1.30]

TBD

2

Measure distance uncertainty

[0.15]

TBD

[Rectangular]

[0.09]

TBD

3

Quality of quiet zone

[1.20]

TBD

[Actual]

[1.20]

TBD

4

Base Station simulator

TBD

TBD

[Normal]

TBD

TBD

5

Channel Emulator

-absolute value

-stability

-linearity

TBD

TBD

Normal

TBD

TBD

6

Amplifier uncertainties

[2.10]

TBD

[Normal]

[1.05]

TBD

7

Random uncertainty

[0.50]

TBD

[Normal]

[0.25]

TBD

8

Throughput measurement: output level step resolution

[0.25]

TBD

Rectangular

[0.14]

TBD

9

DUT sensitivity drift

TBD

TBD

Rectangular

TBD

TBD

10

Signal flatness

TBD

TBD

Normal

TBD

TBD

Stage 1: Calibration measurement

11

Mismatch for calibration process

– loopback cable path

– system input path

– reference antenna

[0.00]

TBD

U-Shaped

[0.00]

TBD

12

Reference antenna positioning misalignment

[0.00]

TBD

[Rectangular]

[0.00]

TBD

13

Quality of quiet zone

[0.60]

TBD

[Actual]

[0.60]

TBD

14

Total uncertainty of the Network Analyzer

[0.73]

TBD

[Normal]

[0.37]

TBD

15

Uncertainty of an absolute gain of the calibration antenna

[0.60]

TBD

[Normal]

[0.30]

TBD

16

Offset of the Phase Center of the Reference Antenna

[0.47]

TBD

[Rectangular]

[0.27]

TBD

Total Expanded Uncertainty, U, with 95% Confidence Interval