A.3 Repeater stimulus signal spectral purity requirements
38.115-13GPPNRRelease 17Repeater conformance testing - Part 1: Conducted conformance testingTS
The reference channels or test models constituting the repeater stimulus signal shall fulfil the spectral purity requirements defined in table A.3-1, where:
– the reference spectral density shall be taken 200 kHz off the carrier centre frequency with an integration bandwidth of 30 kHz.
– Δf is the separation between the channel edge frequency and the nominal -3dB point of the measuring filter closest to the carrier frequency.
– f_offset is the separation between the channel edge frequency and the centre of the measuring filter.
– f_offsetmax is the offset to the frequency 10 MHz outside the downlink operating band.
– Δfmax is equal to f_offsetmax minus half of the bandwidth of the measuring filter.
– the minimum spectral density suppression is related to the reference spectral density.
[Table A.3-1: Repeater stimulus signal spectral purity requirements]
Frequency offset of measurement filter ‑3dB point, Δf |
Frequency offset of measurement filter centre frequency, f_offset |
Minimum requirement |
Measure-ment bandwidth |
|
0 MHz ≤ Δf < 0.15 MHz |
0.015 MHz ≤ f_offset < 0.165 MHz |
-40 + 20*( f_offset -0.015) dBc |
30 kHz |
|
0.15 MHz ≤ Δf < 0.2 MHz |
0.165 MHz ≤ f_offset < 0.215 MHz |
-37 dBc |
30 kHz |
|
0.2 MHz ≤ Δf < 1 MHz |
0.215 MHz ≤ f_offset < 1.015 MHz |
30 kHz |
||
1.015 MHz ≤ f_offset < 1.5 MHz |
-106 dBm |
30 kHz |
||
1 MHz ≤ Δf < 2.8 MHz |
1.5 MHz ≤ f_offset < |
-78 dBm |
1 MHz |
|
2.8 MHz ≤ Δf ≤ Δfmax |
2.85 MHz ≤ f_offset < f_offsetmax |
-80 dBm |
1 MHz |
|
NOTE: Frequencies and bandwidths are given in MHz |
Annex B (normative):
Environmental requirements for the repeater
<Text to be added>
Annex C (informative):
Test tolerances and derivation of test requirements
<Text to be added>
Annex D (informative):
Measurement system set-up
Example of measurement system set-ups are attached below as an informative annex.