7 Applicability overview
38.1143GPPNRRelease 17Repeaters ElectroMagnetic Compatibility (EMC)TS
7.1 Emission
Table 7.1-1: Emission requirements applicability
Phenomenon |
Application |
Equipment test requirement |
Reference clause in the |
Reference standard |
|
NR repeater equipment |
Ancillary equipment |
present document |
|||
Radiated emission |
Enclosure |
applicable for NR repeater type 1-C (Note 1) |
not applicable |
8.2.1 |
ITU-R SM.329 [19] |
Radiated emission |
Enclosure of ancillary equipment |
not applicable |
applicable |
8.2.2 |
CISPR 32 [5] |
Conducted emission |
DC power input/output port |
applicable |
applicable |
8.3 |
CISPR 32 [5] |
Conducted emission |
AC mains input/output port |
applicable |
applicable |
8.4 |
CISPR 32 [5] |
Conducted emission |
Telecommunication port |
applicable |
applicable |
8.5 |
CISPR 32 [5] |
Harmonic current emissions |
AC mains input port |
applicable |
applicable |
8.6 |
IEC 61000-3-2 [8] or (NOTE 2) |
Voltage fluctuations and flicker |
AC mains input port |
applicable |
applicable |
8.7 |
IEC 61000-3-3 [9] or (NOTE 2) |
NOTE 1: Radiated emission requirements for NR repeater type 2-O are described in clause 8.2.1. NOTE 2: Selection of the reference IEC specification is based on the rated input current of the EUT’s power supply. |
7.2 Immunity
Table 7.2-1: Immunity requirements applicability
Phenomenon |
Application |
Equipment test requirement |
Reference |
Reference |
|
NR repeater equipment |
Ancillary equipment |
clause in the present document |
standard |
||
RF electromagnetic field (80 – 6000 MHz) |
Enclosure |
applicable |
applicable |
9.2 |
IEC 61000‑4‑3 [13] |
Electrostatic discharge |
Enclosure |
applicable |
applicable |
9.3 |
IEC 61000‑4‑2 [12] |
Fast transients common mode |
Signal, telecommunications and control ports, DC and AC power input ports |
applicable |
applicable |
9.4 |
IEC 61000‑4‑4 [14] |
RF common mode 0.15 – 80 MHz |
Signal, telecommunications and control ports, DC and AC power input ports |
applicable |
applicable |
9.5 |
IEC 61000‑4‑6 [16] |
Voltage dips and interruptions |
AC mains power input ports |
applicable |
applicable |
9.6 |
IEC 61000‑4‑11 [17] |
Surges, common and differential mode |
AC power input ports and telecommunications port |
applicable |
applicable |
9.7 |
IEC 61000‑4‑5 [15] |