7 Applicability overview

38.1143GPPNRRelease 17Repeaters ElectroMagnetic Compatibility (EMC)TS

7.1 Emission

Table 7.1-1: Emission requirements applicability

Phenomenon

Application

Equipment test requirement

Reference

clause in the

Reference

standard

NR repeater equipment

Ancillary equipment

present document

Radiated emission

Enclosure

applicable for NR repeater type 1-C

(Note 1)

not applicable

8.2.1

ITU-R SM.329 [19]

Radiated emission

Enclosure of ancillary equipment

not applicable

applicable

8.2.2

CISPR 32 [5]

Conducted emission

DC power input/output port

applicable

applicable

8.3

CISPR 32 [5]

Conducted emission

AC mains input/output port

applicable

applicable

8.4

CISPR 32 [5]

Conducted emission

Telecommunication port

applicable

applicable

8.5

CISPR 32 [5]

Harmonic current emissions

AC mains input port

applicable

applicable

8.6

IEC 61000-3-2 [8] or
IEC 61000-3-12 [11]

(NOTE 2)

Voltage fluctuations and flicker

AC mains input port

applicable

applicable

8.7

IEC 61000-3-3 [9] or
IEC 61000-3-11 [10]

(NOTE 2)

NOTE 1: Radiated emission requirements for NR repeater type 2-O are described in clause 8.2.1.

NOTE 2: Selection of the reference IEC specification is based on the rated input current of the EUT’s power supply.

7.2 Immunity

Table 7.2-1: Immunity requirements applicability

Phenomenon

Application

Equipment test requirement

Reference

Reference

NR repeater equipment

Ancillary equipment

clause in the present document

standard

RF electro­magnetic field (80 – 6000 MHz)

Enclosure

applicable

applicable

9.2

IEC 61000‑4‑3 [13]

Electrostatic discharge

Enclosure

applicable

applicable

9.3

IEC 61000‑4‑2 [12]

Fast transients common mode

Signal, telecommunications and control ports, DC and AC power input ports

applicable

applicable

9.4

IEC 61000‑4‑4 [14]

RF common mode

0.15 – 80 MHz

Signal, telecommunications and control ports, DC and AC power input ports

applicable

applicable

9.5

IEC 61000‑4‑6 [16]

Voltage dips and interruptions

AC mains power input ports

applicable

applicable

9.6

IEC 61000‑4‑11 [17]

Surges, common and differential mode

AC power input ports and telecommunications port

applicable

applicable

9.7

IEC 61000‑4‑5 [15]