7.7B Spurious response for DC in FR1
38.101-33GPPNRPart 3: Range 1 and Range 2 Interworking operation with other radiosRelease 17TSUser Equipment (UE) radio transmission and reception
7.7B.1 Intra-band contiguous EN-DC in FR1
Intra-band contiguous EN-DC spurious response requirement and parameters are defined in Table 7.7B.1-1.
Table 7.7B.1-1: Spurious Response Parameters
EN-DC Aggregated Bandwidth, MHz |
≤100 |
>100, ≤120 |
>120, ≤140 |
>140, ≤160 |
Pw in Transmission Bandwidth Configuration, perCC, dBm |
REFSENS + Aggregated BW specific value below |
|||
9 |
||||
Pinterferer, dBm (CW) |
-44 |
|||
NOTE 1: Void. NOTE 2: Void. |
7.7B.2 Intra-band non-contiguous EN-DC in FR1
For the E-UTRA sub-block containing one or multiple CC’s, the requirement is defined in clause 7.7.1 for single carrier operation and in clause 7.7.1A for CA in TS 36.101 [4].
For the NR sub-block, the requirement is defined in clause 7.7 is [2].
7.7B.3 Inter-band EN-DC within FR1
Spurious response requirement for E-UTRA single carrier and CA operation specified in clauses 7.7.1 and 7.7.1A of TS 36.101 [4] and for NR single carrier and CA operation specified in clauses 7.7 and 7.7A of TS 38.101-1 [2] apply for lowest level EN-DC fallbacks (two bands) in clause 5.5.B.4.1 with following conditions
– one E-UTRA uplink carrier with the output power set to 4 dB below PCMAX_L and the NR band whose downlink is being tested has its uplink carrier output power set to 29 dB below PCMAX_L,f,c.
– one NR uplink carrier with the output power set to 4 dB below PCMAX_L,f,c on the NR band with both E-UTRA and NR downlinks being tested with E-UTRA output power set to 29 dB below PCMAX_L,c.
7.7B.3a Inter-band NE-DC within FR1
Spurious response requirement for E-UTRA single carrier and CA operation specified in clauses 7.7.1 and 7.7.1A of TS 36.101 [4] and for NR single carrier and CA operation specified in clauses 7.7 and 7.7A of TS 38.101-1 [2] apply for lowest level NE-DC fallbacks (two bands) in clause 5.5B.4a.1 with following conditions
– one E-UTRA uplink carrier with the output power set to 4 dB below PCMAX_L,c and the NR band whose downlink is being tested has its uplink carrier output power set to 29 dB below PCMAX_L,f,c.
– one NR uplink carrier with the output power set to 4 dB below PCMAX_L,f,c on the NR band with both E-UTRA and NR downlinks being tested with E-UTRA output power set to 29 dB below PCMAX_L,c.
7.7B.4 Inter-band EN-DC including FR2
Spurious response requirement for E-UTRA single carrier and CA operation specified in clauses 7.7.1 and 7.7.1A of TS 36.101 [4] apply for lowest level EN-DC fallbacks (two bands) in clause 5.5B.5.1 with only E-UTRA UL with output power as in TS 36.101 [4] (4 dB below PCMAX_L).
7.7B.4a Inter-band NE-DC including FR2
Spurious response requirement for E-UTRA single carrier and CA operation specified in clauses 7.7.1 and 7.7.1A of TS 36.101 [4] apply for lowest level NE-DC fallbacks (two bands) in clause 5.5B.5.1 with only E-UTRA UL with output power as in TS 36.101 [4] (4 dB below PCMAX_L).
7.7B.5 Inter-band EN-DC including both FR1 and FR2
Spurious response requirement for E-UTRA single carrier and CA operation specified in clauses 7.7.1 and 7.7.1A of TS 36.101 [4] and for NR single carrier and CA operation specified in clauses 7.7 and 7.7A of TS 38.101-1 [2] apply for lowest level EN-DC fallbacks (three bands) in clause 5.5B.6.2 with only E-UTRA UL with output power as in TS 36.101 [4] (4 dB below PCMAX_L).