7.2 Reference sensitivity level

37.145-13GPPActive Antenna System (AAS) Base Station (BS) conformance testingPart 1: conducted conformance testingRelease 17TS

7.2.1 Definition and applicability

The reference sensitivity power level PREFSENS is the minimum mean power received at the TAB connector at which a reference performance requirement shall be met for a specified reference measurement channel.

7.2.2 Minimum Requirement

The single RAT UTRA FDD AAS BS of Wide Area BS class shall fulfil minimum requirements for reference sensitivity specified in TS 25.104 [9], clause 7.2.1.

The single RAT UTRA FDD AAS BS of Medium Range BS class shall fulfil minimum requirements for reference sensitivity specified in TS 25.104 [9], clause 7.2.1.

The single RAT UTRA FDD AAS BS of Local Area BS class shall fulfil minimum requirements for reference sensitivity specified in TS 25.104 [9], clause 7.2.1.

The single RAT UTRA TDD AAS BS of Wide Area BS class shall fulfil minimum requirements for reference sensitivity specified in TS 25.105 [10], clause 7.2.1.1.

The single RAT UTRA TDD AAS BS of Local Area BS class shall fulfil minimum requirements for reference sensitivity specified in TS 25.105 [10], clause 7.2.1.1.

The single RAT E-UTRA AAS BS of Wide Area BS class shall fulfil minimum requirements for reference sensitivity specified in TS 36.104 [11], clause 7.2.1.

The single RAT E-UTRA AAS BS of Medium Range BS class shall fulfil minimum requirements for reference sensitivity specified in TS 36.104 [11], clause 7.2.1.

The single RAT E-UTRA AAS BS of Local Area BS class shall fulfil minimum requirements for reference sensitivity specified in TS 36.104 [11], clause 7.2.1.

The MSR NR AAS BS of Wide Area BS class shall fulfil minimum requirements for reference sensitivity specified in TS 38.104 [36], clause 7.2.1.

The MSR NR AAS BS of Medium Range BS class shall fulfil minimum requirements for reference sensitivity specified in TS 38.104 [36], clause 7.2.1.

The MSR NR AAS BS of Local Area BS class shall fulfil minimum requirements for reference sensitivity specified in TS 38.104 [36], clause 7.2.1.

7.2.3 Test Purpose

To verify that at each TAB connector the reference sensitivity level the performance requirements shall be met for a specified reference measurement channel.

7.2.4 Method of test

7.2.4.1 Initial conditions

Test environment:

– normal; see clause B.2.

– extreme; see clauses B.3 and B.5.

RF channels to be tested for single carrier:

– B, M and T; see clause 4.12.1.

Under extreme test environment, the test shall be performed on each of B, M and T under extreme power supply as defined in annex B.5.

NOTE: Tests under extreme supply conditions also test extreme temperature.

7.2.4.2 Procedure

The minimum requirement is applied to all TAB connectors, the procedure is repeated until all TAB connectors necessary to demonstrate conformance have been tested; see clause 7.1.

1) Connect TAB connector to measurement equipment as shown in clause D.2.1. All TAB connectors not under test shall be terminated.

2) Set all TAB connectors declared in the same RAT and operating band to transmit a signal according to clause 4.12.2 at manufacturers declared rated output power PRated,c,TABC.

3) Start the signal generator for the wanted signal to transmit:

– 12,2kbps DPCH with reference measurement channel defined in annex A in TS 25.141 [18] (PN-9 data sequence or longer) for UTRA FDD,

– UL reference measurement channel (12.2 kbps) defined in clause A.2.1 in TS 25.142 [20] for UTRA TDD 1,28Mcps operation

– The test signal mean power as specified in clause 7.2.5.3 for E-UTRA to the TAB connector.

– The test signal mean power as specified in clause 7.2.5.4 for NR to the TAB connector.

4) For UTRA FDD disable the TPC function.

5) Set the signal generator for the wanted signal power as specified in clause 7.2.5.

6) Measure:

– BER according to annex C in TS 25.141 [18] for FDD UTRA.

– BER according to annex F in TS 25.142 [20] for TDD UTRA.

– Throughput according to annex E in TS 36.141 [17] for E-UTRA and NR.

In addition, for multi-band TAB connector(s), the following steps shall apply:

7) For multi-band TAB connectors and single band tests, repeat the steps above per involved band where single band test configurations and test models shall apply with no carrier activated in the other band.

7.2.5 Test Requirements

7.2.5.1 UTRA FDD operation

The BER measurement result in step 6 of 7.2.4.2 shall not be greater than the limit specified in table 7.2.5.1-1.

Table 7.2.5.1-1: Reference sensitivity levels

BS class

Reference measurement

reference sensitivity level (dBm)

BER

channel data rate

f ≤ 3.0 GHz

3.0 GHz < f ≤ 4.2 GHz

Wide Area BS

12.2 kbps

-120.3

-120.0

BER shall not exceed 0.001

Medium Range BS

12.2 kbps

-110.3

-110.0

BER shall not exceed 0.001

Local Area BS

12.2 kbps

-106.3

-106.0

BER shall not exceed 0.001

NOTE: If the above Test Requirement differs from the Minimum Requirement then the Test Tolerance applied for this test is non-zero. The Test Tolerance for this test is defined in clause 4.1.2 and the explanation of how the Minimum Requirement has been relaxed by the Test Tolerance is given in annex C.

7.2.5.2 UTRA TDD 1,28 Mcps option operation

The BER measurement result in step 4 of 7.2.4.2.2 shall not be greater than the limit specified in table 7.2.5.1-1.

Table 7.2.5.2-1: Test Requirement for BS reference sensitivity level for 1,28 Mcps option

BS class

Reference measurement channel data rate

reference sensitivity level

BER

Wide Area BS

12.2 kbps

-109.3 dBm

BER shall not exceed 0.001

Local Area BS

12.2 kbps

-95.3 dBm

BER shall not exceed 0.001

NOTE: If the above Test Requirement differs from the Minimum Requirement then the Test Tolerance applied for this test is non-zero. The Test Tolerance for this test is defined in clause 4.1.2 and the explanation of how the Minimum Requirement has been relaxed by the Test Tolerance is given in annex C.

7.2.5.3 E-UTRA operation

For each measured E-UTRA carrier, the throughput shall be ≥ 95% of the maximum throughput of the reference measurement channel as specified in clause A.1 in TS 36.141 [17] with parameters specified in table 7.2.5.3-1 for Wide Area BS, in table 7.2.5.3-2 for Local Area BS and in table 7.2.5.3-3 for Medium Range BS.

Table 7.2.5.3-1: Wide Area BS class reference sensitivity levels

E-UTRA channel bandwidth (MHz)

Reference measurement channel

(Note 2)

Reference sensitivity power level, PREFSENS (dBm)

f ≤ 3.0 GHz

3.0 GHz < f ≤ 4.2 GHz

1.4

FRC A1-1

-106.1

-105.8

3

FRC A1-2

-102.3

-102.0

5

FRC A1-3

-100.8

-100.5

10

FRC A1-3 (Note 1)

-100.8

-100.5

15

FRC A1-3 (Note 1)

-100.8

-100.5

20

FRC A1-3 (Note 1)

-100.8

-100.5

NOTE 1: PREFSENS is the power level of a single instance of the reference measurement channel. This requirement shall be met for each consecutive application of a single instance of FRC A1-3 in TS 36.141 [17] mapped to disjoint frequency ranges with a width of 25 resource blocks each.

NOTE 2: FRC reference measurement channels as defined in annex A.1 in TS 36.141 [17].

Table 7.2.5.3-2: Local Area BS class, reference sensitivity levels

E-UTRA

channel bandwidth (MHz)

Reference measurement channel

(Note 2)

Reference sensitivity power level, PREFSENS

(dBm)

f ≤ 3.0 GHz

3.0 GHz < f ≤ 4.2 GHz

1.4

FRC A1-1

-98.1

-97.8

3

FRC A1-2

-94.3

-94.0

5

FRC A1-3

-92.8

-92.5

10

FRC A1-3 (Note 1)

-92.8

-92.5

15

FRC A1-3 (Note 1)

-92.8

-92.5

20

FRC A1-3 (Note 1)

-92.8

-92.5

NOTE 1: PREFSENS is the power level of a single instance of the reference measurement channel. This requirement shall be met for each consecutive application of a single instance of FRC A1-3 in TS 36.141 [17] mapped to disjoint frequency ranges with a width of 25 resource blocks each. This reference measurement channel is not applied for Band 46 nor Band 49.

NOTE 2: FRC reference measurement channels as defined in annex A.1 in TS 36.141 [17].

Table 7.2.5.3-3: Medium Range BS class, reference sensitivity levels

E-UTRA

channel bandwidth (MHz)

Reference measurement channel

(Note 2)

Reference sensitivity power level, PREFSENS

(dBm)

f ≤ 3.0 GHz

3.0 GHz < f ≤ 4.2 GHz

1.4

FRC A1-1

-101.1

-100.8

3

FRC A1-2

-97.3

-97.0

5

FRC A1-3

-95.8

-95.5

10

FRC A1-3 (Note 1)

-95.8

-95.5

15

FRC A1-3 (Note 1)

-95.8

-95.5

20

FRC A1-3 (Note 1)

-95.8

-95.5

NOTE 1: PREFSENS is the power level of a single instance of the reference measurement channel. This requirement shall be met for each consecutive application of a single instance of FRC A1-3 in TS 36.141 [17] mapped to disjoint frequency ranges with a width of 25 resource blocks each.

NOTE 2: FRC reference measurement channels as defined in annex A.1 in TS 36.141 [17].

NOTE: If the above Test Requirement differs from the Minimum Requirement then the Test Tolerance applied for this test is non-zero. The Test Tolerance for this test is defined in clause 4.1.2 and the explanation of how the Minimum Requirement has been relaxed by the Test Tolerance is given in annex C.

7.2.5.4 NR operation

For NR, the throughput shall be ≥ 95% of the maximum throughput of the reference measurement channel as specified in Annex A in TS 38.104 [36] with parameters specified in table 7.2.5.4-1 for Wide Area BS, in table 7.2.5.4-2 for Medium Range BS and in table 7.2.5.4-3 for Local Area BS.

Table 7.2.5.4-1: NR Wide Area BS reference sensitivity levels

BS channel bandwidth

Sub-carrier spacing

Reference measurement channel

Reference sensitivity power level, PREFSENS

(dBm)

(MHz)

(kHz)

f ≤ 3.0 GHz

3.0 GHz < f ≤ 4.2 GHz

4.2 GHz < f ≤ 6.0 GHz

5, 10, 15

15

G-FR1-A1-1

-101

-100.7

-100.2

10, 15

30

G-FR1-A1-2

-101.1

-100.8

-100.3

10, 15

60

G-FR1-A1-3

-98.2

-97.9

-97.4

20, 25, 30, 35, 40, 45, 50

15

G-FR1-A1-4

-94.6

-94.3

-93.8

20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100

30

G-FR1-A1-5

-94.9

-94.6

-94.1

20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100

60

G-FR1-A1-6

-95

-94.7

-94.2

NOTE: PREFSENS is the power level of a single instance of the reference measurement channel. This requirement shall be met for each consecutive application of a single instance of the reference measurement channel mapped to disjoint frequency ranges with a width corresponding to the number of resource blocks of the reference measurement channel each, except for one instance that might overlap one other instance to cover the full BS channel bandwidth.

Table 7.2.5.4-2: NR Medium Area BS reference sensitivity levels

BS channel bandwidth

Sub-carrier spacing

Reference measurement channel

Reference sensitivity power level, PREFSENS

(dBm)

(MHz)

(kHz)

f ≤ 3.0 GHz

3.0 GHz < f ≤ 4.2 GHz

4.2 GHz < f ≤ 6.0 GHz

5, 10, 15

15

G-FR1-A1-1

-96

-95.7

-95.2

10, 15

30

G-FR1-A1-2

-96.1

-95.8

-95.3

10, 15

60

G-FR1-A1-3

-93.2

-92.9

-92.4

20, 25, 30, 35, 40, 45, 50

15

G-FR1-A1-4

-89.6

-89.3

-88.8

20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100

30

G-FR1-A1-5

-89.9

-89.6

-89.1

20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100

60

G-FR1-A1-6

-90

-89.7

-89.2

NOTE: PREFSENS is the power level of a single instance of the reference measurement channel. This requirement shall be met for each consecutive application of a single instance of the reference measurement channel mapped to disjoint frequency ranges with a width corresponding to the number of resource blocks of the reference measurement channel each, except for one instance that might overlap one other instance to cover the full BS channel bandwidth.

Table 7.2.5.4-3: NR Local Area BS reference sensitivity levels

BS channel bandwidth

Sub-carrier spacing

Reference measurement channel

Reference sensitivity power level, PREFSENS

(dBm)

(MHz)

(kHz)

f ≤ 3.0 GHz

3.0 GHz < f ≤ 4.2 GHz

4.2 GHz < f ≤ 6.0GHz

5, 10, 15

15

G-FR1-A1-1

-93

-92.7

-92.2

10, 15

30

G-FR1-A1-2

-93.1

-92.8

-92.3

10, 15

60

G-FR1-A1-3

-90.2

-89.9

-89.4

20, 25, 30, 35, 40, 45, 50

15

G-FR1-A1-4

-86.6

-86.3

-85.8

20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100

30

G-FR1-A1-5

-86.9

-86.6

-86.1

20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100

60

G-FR1-A1-6

-87

-86.7

-86.2

NOTE: PREFSENS is the power level of a single instance of the reference measurement channel. This requirement shall be met for each consecutive application of a single instance of the reference measurement channel mapped to disjoint frequency ranges with a width corresponding to the number of resource blocks of the reference measurement channel each, except for one instance that might overlap one other instance to cover the full BS channel bandwidth.

NOTE: If the above Test Requirement differs from the Minimum Requirement then the Test Tolerance applied for this test is non-zero. The relationship between Minimum Requirements and Test Requirements is defined in clause 4.1 and the explanation of how the Minimum Requirement has been adjusted by the Test Tolerance is given in Annex C.