5 Channel access procedures (core part)
37.1073GPPBase Station (BS) requirements and conformance tests for shared spectrum channel accessRelease 17TS
5.1 Downlink channel access procedure
For downlink operation in Band 46, Band 49, Band n46 and Band n96, a channel access procedure for PDSCH transmission as described in TS 37.213 [5], Clause 4.1.1 is specified.
5.1.1 Channel access parameters
Channel access related parameters for PDSCH are listed in Table 5.1.1-1.
Table 5.1.1-1: Channel access parameters for PDSCH
Parameter |
Unit |
Value |
LBT measurement bandwidth |
MHz |
10, 20 |
Energy detection threshold |
dBm/20MHz dBm/10MHz |
-72 or X (Note) -75 |
Maximum channel occupancy time |
ms |
8 |
NOTE: The specific value X is declared by the vendor. |
5.1.2 Minimum requirement
The Base Station shall be able to assess whether the medium is busy or idle with at least 90% probability, using a channel access procedure with the parameters in Table 5.1.1-1.