C.32a Generic test procedure for MO release of IMS emergency call (when IMS emergency registration had failed)
34.229-13GPPInternet Protocol (IP) multimedia call control protocol based on Session Initiation Protocol (SIP) and Session Description Protocol (SDP)Part 1: Protocol conformance specificationRelease 16TSUser Equipment (UE) conformance specification
The generic test procedure:
1)-3) MO Call release according to procedure C.32, steps 1-3.
4-5) Void.
6)-7) Wait for optional PDN DISCONNECT REQUEST from UE and deactivation of a default emergency EPS Bearer.
Expected sequence
|
Step |
Direction |
Message/Procedure |
Comment |
|
|
UE |
SS |
|||
|
1-3 |
Steps 1-3 defined in annex C.32 |
MO Call release |
||
|
4-5 |
Void |
|||
|
6-7 |
EPS Bearer Deactivation procedure according TS 36.508 [94] subclause 4.5A.15A. |
|||