C.32 Generic test procedure for MO release of IMS call – EPS

34.229-13GPPInternet Protocol (IP) multimedia call control protocol based on Session Initiation Protocol (SIP) and Session Description Protocol (SDP)Part 1: Protocol conformance specificationRelease 16TSUser Equipment (UE) conformance specification

The generic test procedure:

  1. SS makes the UE release the IMS call. SS sends AT command CHCCS [123].

2) Call is released on the UE. SS waits the UE to send a BYE request.

3) SS responds to the BYE request with valid 200 OK response.

4)-5) Deactivation of a dedicated EPS Bearer during call establishment.

Steps 4 and 5 are applicable for a UE with E-UTRA support (TS 34.229-2 A.18/1) only.

Expected sequence

Step

Direction

Message/Procedure

Comment

UE

SS

1

Make the UE release the IMS call

2

🡪

BYE

The UE releases the call with BYE

3

🡨

200 OK

The SS sends 200 OK for BYE

4-5

EPS Bearer Deactivation procedure according TS 36.508 [94] subclause 4.5A.15.

Specific message contents

None.