7 Applicability overview tables
34.1243GPPElectromagnetic compatibility (EMC) requirements for mobile terminals and ancillary equipmentRelease 17TS
7.1 Emission
Table 1: Emission applicability
|
Equipment test requirement |
||||||
|
Phenomenon |
Application |
Equipment connected to fixed AC or DC power installations |
Equipment connected to vehicular DC supplies |
Equipment powered by integral battery |
Reference subclause in the present document |
Reference Standard |
|
Radiated emission |
Enclosure |
applicable |
applicable |
applicable |
8.2 |
ITU-R SM.329 [11] TS25.101 [12] |
|
Conducted emission |
DC power input/output port |
applicable |
applicable |
not applicable |
8.3 |
CISPR 32 [29], |
|
Conducted emission |
AC mains input/output port |
applicable |
not applicable |
not applicable |
8.4 |
CISPR 32 [29] |
|
Harmonic current emissions |
AC mains input port |
applicable |
not applicable |
not applicable |
8.5 |
IEC 61000-3-2 [17] |
|
Voltage fluctuations and flicker |
AC mains input port |
applicable |
not applicable |
not applicable |
8.6 |
IEC 61000-3-3 [18] |
7.2 Immunity
Table 2: Immunity applicability
|
Equipment test requirement |
||||||
|
Phenomenon |
Application |
Equipment connected to fixed AC or DC power installations |
Equipment connected to vehicular DC supplies |
Equipment powered by integral battery |
Reference subclause in the present document |
Reference standard |
|
RF electromagnetic field (80 MHz to 2700 MHz) |
Enclosure |
applicable |
applicable |
applicable |
9.2 |
IEC 61000‑4‑3 [20] |
|
Electrostatic discharge |
Enclosure |
applicable |
applicable |
applicable |
9.3 |
IEC 61000‑4‑2 [19] |
|
Fast transients common mode |
Signal and control ports, DC and AC power input ports |
applicable |
not applicable |
not applicable |
9.4 |
IEC 61000‑4‑4 [21] |
|
RF common mode 0,15 MHz to 80 MHz |
Signal and control ports, DC and AC power input ports |
applicable |
applicable |
applicable |
9.5 |
IEC 61000‑4‑6 [23] |
|
Transients and surges, vehicular environment |
DC power input ports |
not applicable |
applicable |
not applicable |
9.6 |
ISO 7637 Part 1 [6] And ISO 7637 Part 2 [7] |
|
Voltage dips and interruptions |
AC mains power input ports |
applicable |
not applicable |
not applicable |
9.7 |
IEC 61000‑4‑11 [24] |
|
Surges, common and differential mode |
DC and AC power input ports |
applicable |
not applicable |
not applicable |
9.8 |