8.17 Cell Timing

34.123-33GPPPart 3: Abstract test suite (ATS)TSUser Equipment (UE) conformance specification

The timing parameters of the cells are defined in Tables 8.17-1 and 8.17-2.

Table 8.17-1: Cell timing parameters for UTRAN test cases

UTRAN cells

SFN offset

Tcell value

1 or A

0

px_TcellA

2 or B

0

px_TcellB

3 or C

0

px_TcellC

4 or D

3000

px_TcellD

5 or E

3000

px_TcellE

6 or F

678

px_TcellF

7 or G

1356

px_TcellG

8 or H

2034

px_TcellH

NOTE: The first cell created is configured with value 0

Table 8.17-2: Cell timing parameters for LTE-IRAT test cases

UTRAN cells

Tcell value

Comments

5

256

See Note 2

7

512

See note 2

8

0

9

0

NOTE 1: SFN offset of all UTRAN cells is set to 0.

NOTE 2: The first cell created is configured with Tcell value 0.