9.4.6 Location updating / interworking of attach and periodic

34.123-13GPPPart 1: Protocol conformance specificationRelease 15TSUser Equipment (UE) conformance specification

9.4.6.1 Definition

9.4.6.2 Conformance requirement

1) If the UE is in service state NO CELL AVAILABLE, LIMITED SERVICE, PLMN SEARCH or PLMN SEARCH-NORMAL SERVICE when the timer T3212 expires the location updating procedure is delayed until this service state is left.

2) The T3212 time-out value shall not be changed in the NO CELL AVAILABLE, LIMITED SERVICE, PLMN SEARCH and PLMN SEARCH-NORMAL SERVICE states.

3) If the selected cell is in the location area where the UE is registered and IMSI ATTACH is not required and timer T3212 has not expired, then the state is NORMAL SERVICE.

References

1) TS 24.008 clause 4.4.2.

2) TS 24.008 clause 4.4.2.

3) TS 24.008 clause 4.2.1.1.

9.4.6.3 Test purpose

1) To check that if the PLU timer expires while the UE is out of coverage, the UE informs the network of its return to coverage.

2) To check that the PLU timer is not disturbed by cells of forbidden PLMNs.

3) To check that if the PLU timer does not expire while out of coverage and if the mobile returns to the LA where it is updated, the UE does not inform the network of its return to coverage.

9.4.6.4 Method of test

Initial conditions

– System Simulator:

– two cells, a and b, of different PLMNs;

– T3212 is set to 12 minutes on cell a;

– T3212 is set to 6 minutes on cell b;

– IMSI attach is allowed in both cells.

NB: i) Cell b will be mapped to Cell 4 as found in TS 34.108 clause 6.1.4.1.

– User Equipment:

– the UE is deactivated. The PLMN of cell b is entered in the USIM’s forbidden PLMN list.

Related ICS/IXIT statements

None.

Test procedure

The UE is activated and placed in automatic network selection mode. It performs IMSI attach. 1 minute after the end of the IMSI attach procedure, cell a is made unavailable. The UE shall not location update on cell b. 8 minutes after the end of the IMSI attach procedure, cell a is made available. The UE shall not location update on cell a before 11,75 minutes after the end of the IMSI attach procedure. The UE shall perform a periodic location update on cell a between 11,75 minutes and 12,25 minutes after the end of the IMSI attach procedure.

3 minutes after the end of the periodic location updating procedure, cell a is made unavailable. The UE shall not location update on cell b. 14 minutes after the end of the periodic location updating procedure, cell a is made available and cell b is made unavailable. The UE shall perform a location update on cell a before 17 minutes after the end of the periodic location updating procedure.

Expected sequence

Step

Direction

Message

Comments

UE

SS

The following messages are sent and shall be received on cell A.

1

SS

Set the cell type of cell A to the "Serving cell".

Set the cell type of cell B to the "Suitable neighbour cell".

(see note)

1a

UE

The UE is activated in automatic network selection mode.

2

RRC CONNECTION REQUEST

"Establishment cause": Registration.

3

RRC CONNECTION SETUP

4

RRC CONNECTION SETUP

COMPLETE

5

LOCATION UPDATING REQUEST

"location updating type": IMSI attach.

6

LOCATION UPDATING ACCEPT

7

RRC CONNECTION RELEASE

After the sending of this message, the SS waits for the disconnection of the main signalling link.

8

RRC CONNECTION RELEASE

COMPLETE

9

SS

The SS waits 1 minute after step 8.

Set the cell type of cell A to the "non-suitable cell".

(see note)

10

SS

The SS waits 8 minutes after step 8.

Set the cell type of cell A to the "Serving cell".

(see note)

11

RRC CONNECTION REQUEST

This message shall be sent by the UE between 11 minutes 45s and 12 minutes 15s after step 8.

12

RRC CONNECTION SETUP

13

RRC CONNECTION SETUP

COMPLETE

14

LOCATION UPDATING REQUEST

"location updating type": periodic.

15

LOCATION UPDATING ACCEPT

16

RRC CONNECTION RELEASE

After the sending of this message, the SS waits for the disconnection of the main signalling link.

17

RRC CONNECTION RELEASE

COMPLETE

18

SS

The SS waits 3 minutes after step 17.

Set the cell type of cell A to the "non-suitable cell".

(see note)

19

SS

The SS waits 14 minutes after step 17.

Set the cell type of cell A to the "Serving cell".

Set the cell type of cell B to the "non-suitable cell".

(see note)

20

RRC CONNECTION REQUEST

This message shall be sent by the UE before 17 minutes after step 17.

21

RRC CONNECTION SETUP

22

RRC CONNECTION SETUP

COMPLETE

23

LOCATION UPDATING REQUEST

"Location updating type" = periodic.

24

LOCATION UPDATING ACCEPT

25

RRC CONNECTION RELEASE

After the sending of this message, the SS waits for the disconnection of the main signalling link.

26

RRC CONNECTION RELEASE

COMPLETE

27

UE

The UE shall not initiate an RRC connection establishment. This is checked during 12 minutes.

NOTE: The definitions for "Serving cell", "Suitable neighbour cell" and "non-suitable cell" are specified in TS 34.108 clause 6.1 "Reference Radio Conditions for signalling test cases only".

Specific message contents

None.

9.4.6.5 Test requirement

1) At step 20 the UE shall send an RRC CONNECTION REQUEST and at step 23 the UE shall attempt to perform a location update.

2) At step 11 the UE shall send an RRC CONNECTION REQUEST and at step 14 the UE shall attempt to perform a location update.

3) At step 27 the UE shall not initiate an RRC connection during 12minutes.