8.6.5 Inter-RAT Connection Establishment Failure

34.123-13GPPPart 1: Protocol conformance specificationRelease 15TSUser Equipment (UE) conformance specification

8.6.5.1 Connection Establishment Failure logging / Reporting at E-UTRAN inter-RAT handover

8.6.5.1.1 Definition

This test is applicable for all UEs that support Connection Establishment Failure logging services.

8.6.5.1.2 Conformance requirement

[TS 25.331, clause 8.1.3.6 (TP1)]

The UE shall compare the value of the IE "Initial UE identity" in the received RRC CONNECTION SETUP message with the value of the variable INITIAL_UE_IDENTITY.

If the values are different, the UE shall:

1> ignore the rest of the message.

If the values are identical, the UE shall:

1> submit an RRC CONNECTION SETUP COMPLETE message to the lower layers on the uplink DCCH after successful state transition per subclause 8.6.5.1, with the contents set as specified below:

2> if an IE "Logged Connection Establishment Failure Info-FDD" or "Logged Connection Establishment Failure Info-TDD" in variable LOGGED_CONNECTION_ESTABLISHMENT_FAILURE is present and the current Registered PLMN is the same as the PLMN in IE "PLMN Identity" stored in variable LOGGED_CONNECTION_ESTABLISHMENT_FAILURE:

3> include IE "Connection Establishment Failure Info Available".

When the RRC CONNECTION SETUP COMPLETE message has been submitted to lower layers for transmission the UE shall:

[TS 25.331, clause 8.1.3.10(TP1)]

If the UE receives an RRC CONNECTION REJECT message which contains an IE "Initial UE identity" with a value which is identical to the value of the IE "Initial UE identity" in the most recent RRC CONNECTION REQUEST message sent by the UE; but the RRC CONNECTION REJECT message contains a protocol error causing the variable PROTOCOL_ERROR_REJECT to be set to TRUE according to clause 9, the UE shall perform procedure specific error handling as follows:

The UE shall:

1> stop timer T300 or T318, whichever one is running; and

1> clear the entry for the RRC CONNECTION REJECT message in the table "Rejected transactions" in the variable TRANSACTIONS;

1> if V300 is equal to or smaller than N300:

2> set the variable PROTOCOL_ERROR_INDICATOR to TRUE;

2> set the IEs in the RRC CONNECTION REQUEST message according to subclause 8.1.3.3;

2> perform the mapping of the Access Class to an Access Service Class as specified in subclause 8.5.13, and apply the given Access Service Class when accessing the RACH or the common E-DCH (for the Enhanced Uplink in CELL_FACH and Idle mode);

2> submit a new RRC CONNECTION REQUEST message to the lower layers for transmission on the uplink CCCH;

2> increment counter V300;

2> restart timer T300 when the MAC layer indicates success or failure to transmit the message.

1> if V300 is greater than N300:

2> if the UE supports logging of failed RRC Connection Establishment, perform the actions specified in subclause 8.1.3.11;

2> enter idle mode;

2> perform the actions specified in subclause 8.5.2 when entering idle mode from connected mode;

2> consider the procedure to be successful;

2> the procedure ends.

[TS 25.331, clause 8.1.3.11 (TP1)]

If the RRC connection establishment fails and the UE supports logging of failed RRC Connection Establishment, the UE shall perform logging of information for later retrieval. The UE shall store connection establishment failure information in the variable LOGGED_CONNECTION_ESTABLISHMENT_FAILURE by setting its fields as follows:

1> clear the information included in the variable LOGGED_CONNECTION_ESTABLISHMENT_FAILURE, if any;

1> set the IE "PLMN Identity" to the same value as the selected PLMN [4];

1> set the IE "Number Of RRC Msg Transmitted" to indicate the number of times the RRC CONNECTION REQUEST message was transmitted by the UE during the failed RRC Connection Establishment procedure.

1> for TDD:

2> set the IE "FPACH Received" to TRUE if FPACH was received during the failed RRC Connection Establishment procedure.

2> if common E-DCH was used, include the IE "E-RUCCH Failure" and set it to TRUE if failure indication of the E-RUCCH transmission was received during the failed RRC Connection Establishment procedure.

1> set the IE "PLMN Identity" of the Logged Measurements Failed Cell to indicate the IE "PLMN Identity" obtained from system information of the cell where the connection establishment failure was detected;

1> set the IE "Cell ID" to indicate cell identity obtained from system information of the cell where the connection establishment failure was detected;

1> set the IE "CPICH Ec/N0" and "CPICH RSCP" to include measured quantities of the cell where the connection establishment failure was detected for UTRA FDD;

1> set the "P-CCPCH RSCP" to include measured quantities for the cell where the connection establishment failure was detected for UTRA 1.28 Mcps TDD;

1> set the IE "Logged Measurements Intra Frequency Neighbouring Cells list", "Logged Measurements Inter Frequency list", "Logged Measurements E-UTRA frequency list", "Logged Measurements E-UTRA frequency extension list", in order of decreasing ranking quantity as used for cell re-selection in each frequency for at most the following number of neighbouring cells; 6 intra-frequency and 3 inter-frequency neighbours per frequency as well as 3 inter-RAT neighbours, per frequency per RAT;

1> set the IE "Logged Measurements GSM Neighbouring Cells list" in order of decreasing RXLEV.

NOTE: The UE includes the latest available results of the measurement performed for cell reselection, which are performed in accordance with the regular performance requirements as specified in [19].

[TS 25.331, clause 8.5.64.3 (TP1,)]

UE Shall:

1> if IE "Connection Establishment Failure Request" is present:

2> if Registered PLMN is the same as the PLMN in the IE "PLMN Identity" stored in variable LOGGED_CONNECTION_ESTABLISHMENT_FAILURE:

3> set IE "Connection Establishment Failure Report" in the UE INFORMATION RESPONSE as follows:

4> include the IE "Logged Connection Establishment Failure Info-FDD" or "Logged Connection Establishment Failure Info-TDD" and set it to include the entry from the variable LOGGED_CONNECTION_ESTABLISHMENT_FAILURE;

4> set the IE "Time Since Failure" to indicate the elapsed time starting from the Logging of the Connection establishment failure information that is stored in the variable LOGGED_CONNECTION_ESTABLISHMENT_FAILURE.

3> clear the variable LOGGED_CONNECTION_ESTABLISHMENT_FAILURE;

1> transmit a UE INFORMATION RESPONSE message on the uplink DCCH using AM RLC.

Reference

TS 25.304 clauses 5.7 and TS 25.331 clause 8.3.1.6, 8.3.1.10, 8.1.3.11 and 8.5.64.3

8.6.5.1.3 Test Purpose

1. Verify that IE "Logged Connection Establishment Failure Info Available" is indicated at inter-RAT handover to UTRA.

8.6.5.1.4 Method of test

Initial conditions

System Simulator:

2 cells, 1 UTRAN FDD cell (or TDD cell) and 1 E-UTRAN cell. Cell 1 is a UTRAN cell, and Cell 2 is an E-UTRAN Cell. Cell 2 configuration refers to “Cell 1” in TS36.508 clause 6.3. SIB configuration 6 is applied in accordance with TS 34.108 clause 6.1.0a.2

User Equipment:

UE: state Registered, Idle mode (state 2) in Cell 2 as specified in clause 4.5 of TS 34.108.

Test Procedure

Table 8.6.5.1 illustrates the downlink power to be applied for the 2 cells at various time instants of the test execution. Column marked "T0" denotes the initial condition. Subsequent configurations marked “T1”, “T2” and “T3” are applied at the points indicated described in the texts in this clause.

Table 8.6.5.1: Time instances of cell power level and parameter changes

Parameter

Unit

Cell 1(UTRA)

Cell 2(E-UTRA)

Remark

T0

Cell-specific RS EPRE

dBm/15kHz

-70

CPICH Ec (UTRA FDD)

dBm/3.84 MHz

-100

PCCPCH Ec(UTRA LCR TDD)

dBm/1.28 MHz

-100

T1

Cell-specific RS EPRE

dBm/15kHz

-90

CPICH Ec (UTRA FDD)

dBm/3.84 MHz

-65

PCCPCH Ec(UTRA LCR TDD)

dBm/1.28 MHz

-65

T2

Cell-specific RS EPRE

dBm/15kHz

-70

The power level values are such that entering conditions for event 3a are satisfied.

CPICH Ec (UTRA FDD)

dBm/3.84 MHz

-100

PCCPCH Ec (UTRA LCR TDD)

dBm/1.28 MHz

-100

T3

Cell-specific RS EPRE

dBm/15kHz

-90

CPICH Ec (UTRA FDD)

dBm/3.84 MHz

-65

PCCPCH Ec(UTRA LCR TDD)

dBm/1.28 MHz

-65

The SS changes Cell 1 and Cell 2 level according to the row "T1" in table 8.6.5.1.

The UE reselect to Cell 1 and Generic test procedure in TS 36.508 subclause 6.4.2.8 is performed on Cell 1.

The SS sends Paging message to UE.

The UE sends RRC CONNECTION REQUEST message to SS, and SS does not send any message to UE. Waits 2 seconds make T300 expire..

Repeats last procedure 3 times make V300>N300.

Waiting 5 seconds allows UE to enter idle mode and perform Connection Establishment Failure logging

The SS sends Paging message to UE.

The UE transmits an RRC CONNECTION REQUEST message.

When the UE receives RRC CONNECTION SETUP message, the UE transmits an RRC CONNECTION SETUP COMPLETE message.

The UE transmits SERVICE REQUEST message.

SS sends PHYSICAL CHANNEL RECONFIGURATION message to the UE to configure the compressed mode pattern sequence parameters. When the PHYSICAL CHANNEL RECONFIGURATION COMPLETE is received from the UE, the SS sends a MEASUREMENT CONTROL message.

SS adjusts cell power level according to columns "T1" in tables 8.6.5.1, and UE send MEASUREMENT REPORT to SS.

The UE receive “HANDOVER FROM UTRAN COMMAND” message from Cell 1, and handover to E-UTRAN Cell 2,

SS adjust cell power level according to columns "T2" in tables 8.6.5.1, and UE sends MeasurementReport message to SS.

SS transmits a MobilityFromEUTRACommand message to UE.

The UE handover to UTRAN cell from E-UTRAN cell, and send HANDOVER TO UTRAN COMPLETE message and complete handover to Cell 1.

SS transmits a UE INFORMATION REQUEST message to get Connection Establishment Failure Report

The UE shall transmit a UE INFORMATION REPONSE message, with Connection Establishment Failure Report on Cell 1

Expected Sequence

Step

Direction

Message

Comment

UE

SS

0A

The SS changes Cell 1 and Cell 2 level according to the row "T1" in table8.6.5.1.

0B

The UE reselect to Cell 1 and Generic test procedure in TS 36.508 subclause 6.4.2.8 is performed on Cell 1.

NOTE: The UE performs an RAU procedure and the RRC connection is released.

1

<–

Paging

SS transmits a Paging message.

2

–>

RRC CONNECTION REQUEST

The UE transmits an RRC CONNECTION REQUEST message.

3

SS does not send any message to UE. Waits 2 seconds make T300 expire.

4

Repeats “step 2 and step 3” 3 times make V300>N300.

5

Waiting 5 seconds allows UE to enter idle mode and perform Connection Establishment Failure logging

6

<–

Paging

SS transmits a Paging message.

7

à

RRC CONNECTION REQUEST

8

ß

RRC CONNECTION SETUP

9

à

RRC CONNECTION SETUP COMPLETE

10

–>

RRC: INITIAL DIRECT TRANSFER

NAS: SERVICE REQUEST

The UE transmits SERVICE REQUEST message.

10A

SS

The SS starts ciphering and integrity protection

10B

SS

The SS establishes the radio access bearer for the active PDP context, using the same QoS that was used at activation

11

PHYSICAL CHANNEL RECONFIGURATION

Compressed mode pattern sequence parameters are loaded to UE.

12

PHYSICAL CHANNEL RECONFIGURATION COMPLETE

13

MEASUREMENT CONTROL

SS configures event 3a in the UE. If the UE requires compressed mode (refer ICS/IXIT), compressed mode is started.

14

SS re-adjusts the downlink transmission power settings according to columns "T1" in tables 8.6.5.1.

15

MEASUREMENT REPORT

After about 2s, the UE sends a MEASUREMENT REPORT to SS triggered by event 3a.

16

ß

HANDOVER FROM UTRAN COMMAND

The SS transmits a HANDOVER FROM UTRAN COMMAND message to UE.

17

RRCConnectionReconfigurationComplete

The UE shall send a RRCConnectionReconfigurationComplete message to Cell 2.

17A

Generic test procedure in TS 36.508 subclause 6.4.2.10 is performed on Cell 2.

NOTE: The UE performs tracking area updating procedure without ISR and security reconfiguration after successful completion of handover from UTRA.

18

ß

RRCConnectionReconfiguration

The SS transmits an RRCConnectionReconfiguration message to setup inter RAT measurement on Cell 2.

19

RRCConnectionReconfigurationComplete

The UE transmits an RRCConnectionReconfigurationComplete message to confirm the setup of inter RAT measurement on Cell 2.

20

SS re-adjusts the downlink transmission power settings according to columns "T2" in tables 8.6.5.1.

21

MeasurementReport

The UE transmits a MeasurementReport message to Cell 2.

22

ß

MobilityFromEUTRACommand

The SS transmits a MobilityFromEUTRACommand message on Cell 2.

23

HANDOVER TO UTRAN COMPLETE

The UE transmit a HANDOVER TO UTRAN COMPLETE message on Cell 1.

EXCEPTION: Step 23Aa1 depend on UE implementation

23Aa1

ROUTING AREA UPDATE REQUEST

The UE sends a ROUTING AREA UPDATE REQUEST message within [2] seconds.

24

ß

SECURITY MODE COMMAND

The SS transmits a SECURITY MODE COMMAND message on Cell 1 in order to activate integrity protection.

25

SECURITY MODE COMPLETE

The UE transmits a SECURITY MODE COMPLETE message on Cell 1.

EXCEPTION: Steps 25Aa1 to 25Aa2 depend on UE implementation; the second "lower case letter" identifies a step sequence that takes place if the UE sent a ROUTING AREA UPDATE REQUEST message at 23Aa1.

25Aa1

ß

ROUTING AREA UPDATE ACCEPT

The SS transmits a ROUTING AREA UPDATE ACCEPT message.

25Aa2

à

ROUTING AREA UPDATE COMPLETE

The UE transmits a ROUTING AREA UPDATE COMPLETE message.

26

ß

UE INFORMATION REQUEST

SS sends an UE INFORMATION REQUEST message to get Connection Establishment Failure Report.

27

à

UE INFORMATION RESPONSE

The UE shall send an UE INFORMATION RESPONSE message with Connection Establishment Failure Report on Cell 1.

EXCEPTION: Steps 28a1 to 28a3 depend on UE implementation; the second "lower case letter" identifies a step sequence that takes place if the UE did not send a ROUTING AREA UPDATE REQUEST message at step 23Aa1.

28a1

à

ROUTING AREA UPDATE REQUEST

The UE sends a ROUTING AREA UPDATE REQUEST message.

28a2

ß

ROUTING AREA UPDATE ACCEPT

The SS transmits a ROUTING AREA UPDATE ACCEPT message.

28a3

à

ROUTING AREA UPDATE COMPLETE

The UE transmits a ROUTING AREA UPDATE COMPLETE message.

Specific Message Contents

Conditions for specific message contents

Condition

Explanation

Band > 64

If E-UTRA band > 64 is selected

SYSTEM INFORMATION TYPE 1 (Initial conditions and all steps)

– UE Timers and constants in idle mode

-T300

2000 milliseconds

-N300

3

-T312

10 seconds

– N312

1

SYSTEM INFORMATION BLOCK TYPE 19 (Initial conditions and all steps)

Use same message sub-clause 6.1 of TS 34.108, with the exception of that frequency of Cell 2 is listed in the IE "E-UTRA frequency and priority info list".

PHYSICAL CHANNEL RECONFIGURATION (FDD) (Step 11)

Information Element

Value/remark

Message Type

RRC transaction identifier

Arbitrarily selects an unused integer between 0 to 3

Integrity check info

– Message authentication code

SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I.

– RRC message sequence number

SS provides the value of this IE, from its internal counter.

Integrity protection mode info

Not Present

Ciphering mode info

Not Present

Activation time

Not Present

Delay restriction flag

Not Present

New U-RNTI

Not Present

New C-RNTI

Not Present

New H-RNTI

Not Present

New Primary E-RNTI

Not Present

New Secondary E-RNTI

Not Present

RRC State indicator

CELL_DCH

UE Mobility State Indicator

Not Present

UTRAN DRX cycle length coefficient

Not Present

CN information info

Not Present

URA identity

Not Present

RNC support for change of UE capability

Not Present

Reconfiguration in response to requested change of UE capability

Not Present

Downlink counter synchronization info

Not Present

Frequency info

Not Present

DTX-DRX timing information

Not Present

DTX-DRX Information

Not Present

HS-SCCH less Information

Not Present

MIMO parameters

Not Present

HARQ Info

Not Present

Maximum allowed UL TX power

Not Present

CHOICE channel requirement

Not Present

E-DCH Info

Not Present

Downlink HS-PDSCH Information

Not Present

Downlink information common for all radio links

– Downlink DPCH info common for all RL

Not Present

– DPCH compressed mode info

– TGPSI

1

– TGPS Status Flag

Deactivate

– TGCFN

Not Present

– Transmission gap pattern sequence configuration parameters

– TGMP

E-UTRA measurement

– TGPRC

Infinity

– TGSN

8

– TGL1

10

– TGL2

Not Present

– TGD

undefined

– TGPL1

12

– TGPL2

Not Present

– RPP

Mode 0

– ITP

Mode 0

– CHOICE UL/DL Mode

UL and DL, UL only or DL only (depending on the UE capability)

– Downlink compressed mode method

HLS(or not sent, depending on the UE capability)

– Uplink compressed mode method

HLS(or not sent, depending on the UE capability)

– Downlink frame type

B

– DeltaSIR1

20 (2.0)

– DeltaSIRAfter1

10 (1.0)

– DeltaSIR2

Not Present

– DeltaSIRAfter2

Not Present

– N identify abort

Not Present

– T Reconfirm abort

Not Present

– TX Diversity mode

Not Present

– SSDT information

Not Present

– Default DPCH Offset Value

Not Present

Downlink information for each radio link

Not Present

MBMS PL Service Restriction Information

Not Present

MEASUREMENT CONTROL (FDD) (Step 13)

Information Element

Value/remark

Conditions

Message Type

RRC transaction identifier

Arbitrarily selects an unused integer between 0 to 3

Integrity check info

– Message authentication code

SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I.

– RRC message sequence number

SS provides the value of this IE, from its internal counter.

Measurement Identity

3

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Report Transfer Mode

Acknowledged mode RLC

– Periodical Reporting/Event Trigger Reporting Mode

Event trigger

Additional measurement list

Not present

CHOICE Measurement type

Inter-RAT measurement

– CHOICE Inter-RAT measurement objects

E-UTRA frequency list

– CHOICE E-UTRA frequency removal

Remove no frequencies

– New frequencies

– E-UTRA carrier frequency

Downlink EARFCN of E-UTRA Cell

– E-UTRA carrier frequency

65535

Band > 64

– EARFCN extension

Downlink EARFCN of E-UTRA Cell

Band > 64

– Measurement bandwidth

Same downlink system bandwidth as used for E-UTRA Cell

– Blacklisted cells list

Not present

– Inter-RAT measurement quantity

– Measurement quantity for UTRAN quality estimate

– Filter coefficient

0

– CHOICE mode

FDD

– Measurement quantity

CPICH Ec/N0

– CHOICE system

E-UTRA

– Measurement quantity

RSRP

– Filter coefficient

0

– Inter-RAT reporting quantity

– UTRAN estimated quality

FALSE

– CHOICE system

E-UTRA

– Reporting quantity

both

– Reporting cell status

Not present

– CHOICE report criteria

Inter-RAT measurement reporting criteria

– Parameters required for each event

1 entry

– Inter-RAT event identity

Set according to specific test.

– Threshold own system

-66 dB

– W

0

– Threshold other system

-55 (-80 dBm)

– Hysteresis

0

– Time to trigger

10 ms

– Reporting cell status

– CHOICE reported cell

Report cells within active set or within virtual active set or of the other RAT

– Maximum number of reported cells

2

– Idle Interval Information

Not present

DPCH Compressed mode status info

– TGPS reconfiguration CFN

(Current CFN + (250 – TTI/10msec)) mod 256

– Transmission gap pattern sequence

1 entry

– TGPSI

1

– TGPS Status Flag

activate

– TGCFN

(Current CFN + (252 – TTI/10msec)) mod 256

MEASUREMENT CONTROL (TDD) (Step 13)

Information Element

Value/remark

Conditions

Message Type

RRC transaction identifier

Arbitrarily selects an unused integer between 0 to 3

Integrity check info

– Message authentication code

SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I.

– RRC message sequence number

SS provides the value of this IE, from its internal counter.

Measurement Identity

3

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Report Transfer Mode

Acknowledged mode RLC

– Periodical Reporting/Event Trigger Reporting Mode

Event trigger

Additional measurement list

Not present

CHOICE Measurement type

Inter-RAT measurement

– CHOICE Inter-RAT measurement objects

E-UTRA frequency list

– CHOICE E-UTRA frequency removal

Remove no frequencies

– New frequencies

– E-UTRA carrier frequency

Downlink EARFCN of E-UTRA Cell

– E-UTRA carrier frequency

65535

Band > 64

– EARFCN extension

Downlink EARFCN of E-UTRA Cell

Band > 64

– Measurement bandwidth

Same downlink system bandwidth as used for E-UTRA Cell

– Blacklisted cells list

Not present

– Inter-RAT measurement quantity

– Measurement quantity for UTRAN quality estimate

– Filter coefficient

0

– CHOICE mode

TDD

– Measurement quantity

Primary CCPCH RSCP

– CHOICE system

E-UTRA

– Measurement quantity

RSRP

– Filter coefficient

0

– Inter-RAT reporting quantity

– UTRAN estimated quality

FALSE

– CHOICE system

E-UTRA

– Reporting quantity

both

– Reporting cell status

Not present

– CHOICE report criteria

Inter-RAT measurement reporting criteria

– Parameters required for each event

1 entry

– Inter-RAT event identity

Set according to specific test.

– Threshold own system

-66 dB

– W

0

– Threshold other system

-55 (-80 dBm)

– Hysteresis

0

– Time to trigger

10 ms

– Reporting cell status

– CHOICE reported cell

Report cells within active set or within virtual active set or of the other RAT

– Maximum number of reported cells

2

– Idle Interval Information

Not present

DPCH Compressed mode status info

Not present

MEASUREMENT REPORT (Step 15)

Information Element

Value/remark

Conditions

Integrity check info

– Message authentication code

This IE is checked to see if it is present. The value is compared against the XMAC-I value computed by SS. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I.

– RRC Message sequence number

This IE is checked to see if it is present. The value is used by SS to compute the XMAC-I value.

Activation time

(256+CFN-(CFN MOD 8 + 8)) MOD 256

Measurement identity

3

Measured Results

Not present

Measured results on RACH

Not present

Additional measured results

Not present

Event results

Not present

Inter-RAT cell info indication

Not present

E-UTRA Measured Results

– E-UTRA measured results list

1 entry

– E-UTRA Carrier Frequency

– Measured E-UTRA cells

1 entry

– Physical Cell Identity

PhysicalCellIdentity of Cell 2

– RSRP

Set according to specific test.

– RSRQ

Set according to specific test.

E-UTRA Event Results

– Inter-RAT event identity

Set according to specific test.

– E-UTRA events results list

1 entry

– E-UTRA Carrier Frequency

Downlink EARFCN of Cell 2

– E-UTRA Carrier Frequency

65535

Band > 64

– Reported cells

1 entry

– Physical Cell Identity

PhysicalCellIdentity of Cell 2

– E-UTRA events results extension list

1 entry

Band > 64

– EARFCN extension

Downlink EARFCN of Cell 2

HANDOVER TO UTRAN COMPLETE (Step 23)

Information Element

Value/remark

Message Type

UE Information elements

– START list

Not checked

– CN domain identity

Not checked

– START

Not checked

RB Information elements

– COUNT-C activation time

Not checked

Other Information elements

– Connection Establishment Failure Info Available

TRUE

UE INFORMATION REQUEST (Step 26)

Information Element

Value/remark

Message Type

RRC transaction identifier

Arbitrarily selects an integer between 0 and 3

Integrity check info

– message authentication code

SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I.

– RRC message sequence number

SS provides the value of this IE, from its internal counter.

Logged Measurements Report Request

Not Present

Logged ANR Report Request

Not Present

Connection Establishment Failure Request

TRUE

UE INFORMATION RESPONSE (FDD) (Step 27)

Information Element

Value/remark

Message Type

RRC transaction identifier

Arbitrarily selects an integer between 0 and 3

Integrity check info

– message authentication code

SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I.

– RRC message sequence number

SS provides the value of this IE, from its internal counter.

Connection Establishment Failure Report

– Time Since Failure

[0..172800] Indicates the elapsed time in seconds between Logging and reporting of Connection establishment failure info.

– CHOICE mode

FDD

– Logged Connection Establishment Failure Info-FDD

– Number Of RRC Msg Transmitted

4

– Logged Measurements Failed Cell

– Cell ID

Cell 1

– CPICH RSCP

(0..91)

– CPICH Ec/N0

(0..49)

– CPICH Ec/N0

(0..49)

UE INFORMATION RESPONSE (TDD) (Step 27)

Information Element

Value/remark

Message Type

RRC transaction identifier

Arbitrarily selects an integer between 0 and 3

Integrity check info

– message authentication code

SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I.

– RRC message sequence number

SS provides the value of this IE, from its internal counter.

Connection Establishment Failure Report

– Time Since Failure

[0…172800] Indicates the elapsed time in seconds between Logging and reporting of Connection establishment failure info.

– CHOICE mode

TDD

– Logged Connection Establishment Failure Info-TDD

– Number Of RRC Msg Transmitted

4

– FPACH Received

Not checked

– E-RUCCH Failure

Not checked

– Logged Measurements Failed Cell

– Cell ID

Cell 1

– Primary CCPCH RSCP

(0..91)

8.6.5.1.5 Test requirements

At step 23, The UE shall send HANDOVER TO UTRAN COMPLETE message to SS, and include IE “Connection Establishment Failure Info Available” as True (TP1).

At step 27, The UE shall send an UE INFORMATION RESPONSE message with Connection Establishment Failure Report on cell 1. (TP1).

8.6.5.2 Connection Establishment Failure logging / Logging and reporting / E-UTRA Inter-RAT measurements

8.6.5.2.1 Definition

This test is applicable for all UEs that support Connection Establishment Failure logging services.

8.6.5.2.2 Conformance requirement

[TS 25.331, clause 8.1.3.6 (TP1)]

The UE shall compare the value of the IE "Initial UE identity" in the received RRC CONNECTION SETUP message with the value of the variable INITIAL_UE_IDENTITY.

If the values are different, the UE shall:

1> ignore the rest of the message.

If the values are identical, the UE shall:

1> submit an RRC CONNECTION SETUP COMPLETE message to the lower layers on the uplink DCCH after successful state transition per subclause 8.6.3.3, with the contents set as specified below:

2> if an IE "Logged Connection Establishment Failure Info-FDD" or "Logged Connection Establishment Failure Info-TDD" in variable LOGGED_CONNECTION_ESTABLISHMENT_FAILURE is present and the current Registered PLMN is the same as the PLMN in IE "PLMN Identity" stored in variable LOGGED_CONNECTION_ESTABLISHMENT_FAILURE:

3> include IE "Connection Establishment Failure Info Available".

When the RRC CONNECTION SETUP COMPLETE message has been submitted to lower layers for transmission the UE shall:

[TS 25.331, clause 8.1.3.10(TP1)]

If the UE receives an RRC CONNECTION REJECT message which contains an IE "Initial UE identity" with a value which is identical to the value of the IE "Initial UE identity" in the most recent RRC CONNECTION REQUEST message sent by the UE; but the RRC CONNECTION REJECT message contains a protocol error causing the variable PROTOCOL_ERROR_REJECT to be set to TRUE according to clause 9, the UE shall perform procedure specific error handling as follows:

The UE shall:

1> stop timer T300 or T318, whichever one is running; and

1> clear the entry for the RRC CONNECTION REJECT message in the table "Rejected transactions" in the variable TRANSACTIONS;

1> if V300 is equal to or smaller than N300:

2> set the variable PROTOCOL_ERROR_INDICATOR to TRUE;

2> set the IEs in the RRC CONNECTION REQUEST message according to subclause 8.1.3.3;

2> perform the mapping of the Access Class to an Access Service Class as specified in subclause 8.5.13, and apply the given Access Service Class when accessing the RACH or the common E-DCH (for the Enhanced Uplink in CELL_FACH and Idle mode);

2> submit a new RRC CONNECTION REQUEST message to the lower layers for transmission on the uplink CCCH;

2> increment counter V300;

2> restart timer T300 when the MAC layer indicates success or failure to transmit the message.

1> if V300 is greater than N300:

2> if the UE supports logging of failed RRC Connection Establishment, perform the actions specified in subclause 8.1.3.11;

2> enter idle mode;

2> perform the actions specified in subclause 8.5.2 when entering idle mode from connected mode;

2> consider the procedure to be successful;

2> the procedure ends.

[TS 25.331, clause 8.1.3.11 (TP1)]

If the RRC connection establishment fails and the UE supports logging of failed RRC Connection Establishment, the UE shall perform logging of information for later retrieval. The UE shall store connection establishment failure information in the variable LOGGED_CONNECTION_ESTABLISHMENT_FAILURE by setting its fields as follows:

1> clear the information included in the variable LOGGED_CONNECTION_ESTABLISHMENT_FAILURE, if any;

1> set the IE "PLMN Identity" to the same value as the selected PLMN [4];

1> set the IE "Number Of RRC Msg Transmitted" to indicate the number of times the RRC CONNECTION REQUEST message was transmitted by the UE during the failed RRC Connection Establishment procedure.

1> for TDD:

2> set the IE "FPACH Received" to TRUE if FPACH was received during the failed RRC Connection Establishment procedure.

2> if common E-DCH was used, include the IE "E-RUCCH Failure" and set it to TRUE if failure indication of the E-RUCCH transmission was received during the failed RRC Connection Establishment procedure.

1> set the IE "PLMN Identity" of the Logged Measurements Failed Cell to indicate the IE "PLMN Identity" obtained from system information of the cell where the connection establishment failure was detected;

1> set the IE "Cell ID" to indicate cell identity obtained from system information of the cell where the connection establishment failure was detected;

1> set the IE "CPICH Ec/N0" and "CPICH RSCP" to include measured quantities of the cell where the connection establishment failure was detected for UTRA FDD;

1> set the "P-CCPCH RSCP" to include measured quantities for the cell where the connection establishment failure was detected for UTRA 1.28 Mcps TDD;

1> set the IE "Logged Measurements Intra Frequency Neighbouring Cells list", "Logged Measurements Inter Frequency list", "Logged Measurements E-UTRA frequency list", "Logged Measurements E-UTRA frequency extension list", in order of decreasing ranking quantity as used for cell re-selection in each frequency for at most the following number of neighbouring cells; 6 intra-frequency and 3 inter-frequency neighbours per frequency as well as 3 inter-RAT neighbours, per frequency per RAT;

1> set the IE "Logged Measurements GSM Neighbouring Cells list" in order of decreasing RXLEV.

NOTE: The UE includes the latest available results of the measurement performed for cell reselection, which are performed in accordance with the regular performance requirements as specified in [19].

[TS 25.331, clause 8.5.64.3 (TP1)]

UE Shall:

1> if IE "Connection Establishment Failure Request" is present:

2> if Registered PLMN is the same as the PLMN in the IE "PLMN Identity" stored in variable LOGGED_CONNECTION_ESTABLISHMENT_FAILURE:

3> set IE "Connection Establishment Failure Report" in the UE INFORMATION RESPONSE as follows:

4> include the IE "Logged Connection Establishment Failure Info-FDD" or "Logged Connection Establishment Failure Info-TDD" and set it to include the entry from the variable LOGGED_CONNECTION_ESTABLISHMENT_FAILURE;

4> set the IE "Time Since Failure" to indicate the elapsed time starting from the Logging of the Connection establishment failure information that is stored in the variable LOGGED_CONNECTION_ESTABLISHMENT_FAILURE.

3> clear the variable LOGGED_CONNECTION_ESTABLISHMENT_FAILURE;

1> transmit a UE INFORMATION RESPONSE message on the uplink DCCH using AM RLC.

Reference

TS 25.304 clause 5.7 and TS 25.331 clause 8.3.1.6, 8.3.1.10, 8.1.3.11 and 8.5.64.3

.8.6.5.2.3 Test Purpose

1. Verify that E-UTRA neighbour cell information (IE "Logged Measurements E-UTRA frequency list") is reported in connection establishment failure information in UE INFORMATION RESPONSE message.

8.6.5.2.4 Method of test

Initial conditions

System Simulator:

2 cells, Cell 1 and Cell 2(E-UTRA)

User Equipment:

UE: Registered Idle mode (state 3) in Cell 1 as specified in clause 7.4 of TS 34.108.

Test procedure

Table 8.6.5.2 illustrates the downlink power to be applied for the 2 cells at various time instants of the test execution. Column marked "T0" denotes the initial condition, while column marked "T1" and "T2" is to be applied subsequently. The exact instants on which these values shall be applied are described in the texts in this clause.

Table 8.6.5.2: Time instances of cell power level and parameter changes

Parameter

Unit

Cell 1(UTRA)

Cell 2(E-UTRA)

T0

Cell-specific RS EPRE

dBm/15kHz

-90

CPICH Ec (UTRA FDD)

dBm/3.84 MHz

-65

PCCPCH Ec(UTRA LCR TDD)

dBm/1.28 MHz

-65

T1

Cell-specific RS EPRE

dBm/15kHz

-70

CPICH Ec (UTRA FDD)

dBm/3.84 MHz

-100

PCCPCH Ec(UTRA LCR TDD)

dBm/1.28 MHz

-100

T2

Cell-specific RS EPRE

dBm/15kHz

-90

CPICH Ec (UTRA FDD)

dBm/3.84 MHz

-65

PCCPCH Ec(UTRA LCR TDD)

dBm/1.28 MHz

-65

SS applies the downlink transmission power settings, according to the values in columns "T1" of table 8.6.5.2. The UE shall find that the cell 2 is better and attempt to perform a cell reselection.

UE reselects to cell 2 and moves to RRC_IDLE mode.

SS applies the downlink transmission power settings, according to the values in columns "T2" of table 8.6.5.2. The UE shall find that the cell 1 is and perform a cell reselection to cell1.

The SS sends Paging message to UE.

The UE sends RRC CONNECTION REQUEST message to SS, and SS does not send any message to UE. Waits 2 seconds make T300 expire.

Repeats last procedure 3 times make V300>N300.

The SS sends Paging message to UE.

The UE transmits an RRC CONNECTION REQUEST message.

When the UE receives RRC CONNECTION SETUP message, the UE should transmit an RRC CONNECTION SETUP COMPLETE message including IE "Connection Establishment Failure Info Available".

The UE transmits SERVICE REQUEST message.

The SS sends an UE INFORMATION REQUEST message to get Connection Establishment Failure Report.

The UE shall send an UE INFORMATION RESPONSE message with Connection Establishment Failure Report on cell 1, include the "Logged Measurements E-UTRA Frequency Neighbours List" with Cell 2 information in the Report.

The SS sends RRC CONNECTION RELEASE message to UE, and makes UE enter idle mode.

Expected sequence

Step

Direction

Message

Comments

UE

SS

1

SS applies the downlink transmission power settings, according to the values in columns "T1" of table 8.6.5.2. The UE shall find that the cell 2 is better and attempt to perform a cell reselection.

2

Call generic procedure in 36.508 subclause 6.4.2.7A-1, UE reselects to cell 2. The UE performs a TAU procedure and the RRC Connection is released.

3

SS applies the downlink transmission power settings, according to the values in columns "T2" of table 8.6.5.2. The UE shall find that the cell 1 is better and attempt to perform a cell reselection.

4

Call generic procedure in 36.508 subclause 6.4.2.8-1, UE reselects to Cell 1. The UE performs a RAU procedure and the RRC Connection is released.

5

<–

Paging

SS transmits a Paging message.

6

–>

RRC CONNECTION REQUEST

The UE transmits an RRC CONNECTION REQUEST message.

7

SS does not send any message to UE. Waits 2 seconds make T300 expire.

8

Repeats “step 6 and step 7” 3 times make V300>N300.

9

Waiting 5 seconds allows UE to enter idle mode and perform Connection Establishment Failure logging

10

<–

Paging

SS transmits a Paging message.

11

–>

RRC CONNECTION REQUEST

The UE transmits an RRC CONNECTION REQUEST message.

12

<–

RRC CONNECTION SETUP

SS transmit an RRC CONNECTION SETUP message.

13

–>

RRC CONNECTION SETUP COMPLETE

The UE shall transmit an RRC CONNECTION SETUP COMPLETE message including IE "Connection Establishment Failure Info Available".

14

–>

RRC: INITIAL DIRECT TRANSFER

NAS: SERVICE REQUEST

The UE transmits SERVICE REQUEST message.

15

<–

UE INFORMATION REQUEST

SS sends an UE INFORMATION REQUEST message to get Connection Establishment Failure Report.

16

–>

UE INFORMATION RESPONSE

The UE shall send an UE INFORMATION RESPONSE message with Connection Establishment Failure Report on cell 1.

17

<–

RRC CONNECTION RELEASE

SS transmits a RRC CONNECTION RELEASE message to release RRC connection and moves to idle mode.

18

–>

RRC CONNECTION RELEASE COMPLETE

UE confirms the connection release and returns to Idle mode

Specific message contents

All messages have the same content as defined in 34.108 clause 9 with the following exceptions:

SYSTEM INFORMATION TYPE 1 (Initial conditions and all steps)

– UE Timers and constants in idle mode

-T300

2000 milliseconds

-N300

3

-T312

10 seconds

– N312

1

SYSTEM INFORMATION BLOCK TYPE 19 (Initial conditions and all steps)

Use same message sub-clause 6.1 of TS 34.108, with the exception of that frequency of Cell 2 is listed in the IE "E-UTRA frequency and priority info list".

Conditions for specific message contents

Condition

Explanation

Band > 64

If E-UTRA band > 64 is selected

RRC CONNECTION SETUP COMPLETE (step 13)

Information Element

Value/remark

Message Type

RRC transaction identifier

The value of this IE is checked to see that it matches the value of the same IE transmitted in the downlink RRC CONNECTION SETUP message.

Connection Establishment Failure Info Available

TRUE

UE INFORMATION REQUEST (Step 15)

Information Element

Value/remark

Message Type

RRC transaction identifier

Arbitrarily selects an integer between 0 and 3

Integrity check info

– message authentication code

SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I.

– RRC message sequence number

SS provides the value of this IE, from its internal counter.

Logged Measurements Report Request

Not Present

Logged ANR Report Request

Not Present

Connection Establishment Failure Request

TRUE

UE INFORMATION RESPONSE (FDD) (Step 16)

Information Element

Value/remark

Conditions

Message Type

RRC transaction identifier

Arbitrarily selects an integer between 0 and 3

Integrity check info

– message authentication code

SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I.

– RRC message sequence number

SS provides the value of this IE, from its internal counter.

Connection Establishment Failure Report

– Time Since Failure

[0…172800] Indicates the elapsed time in seconds between Logging and reporting of Connection establishment failure info.

– CHOICE mode

FDD

– Logged Connection Establishment Failure Info-FDD

– Number Of RRC Msg Transmitted

4

– Logged Measurements Failed Cell

– Cell ID

Cell 1

– CPICH RSCP

(0..91)

– CPICH Ec/N0

(0..49)

– Logged Measurements Inter-RAT Neighbour cells list

– Logged Measurements E-UTRA frequency list

1 entry

– E-UTRA Carrier Frequency

Same as cell 2

– E-UTRA Carrier Frequency

65535

Band > 64

– Logged Measurements E-UTRA Frequency Neighbours List

1 entry

– Physical Cell Identity

Same as cell 2

– RSRP

(0..97)

– RSRQ

(0..34)

– Logged Measurements E-UTRA frequency extension list

1 entry

Band > 64

– EARFCN extension

Same as cell 2

UE INFORMATION RESPONSE (TDD) (Step 16)

Information Element

Value/remark

Conditions

Message Type

RRC transaction identifier

Arbitrarily selects an integer between 0 and 3

Integrity check info

– message authentication code

SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I

– RRC message sequence number

SS provides the value of this IE, from its internal counter

Connection Establishment Failure Report

– Time Since Failure

[0…172800] Indicates the elapsed time in seconds between Logging and reporting of Connection establishment failure info

– CHOICE mode

TDD

– Logged Connection Establishment Failure Info-TDD

– Number Of RRC Msg Transmitted

4

– FPACH Received

Not checked

– E-RUCCH Failure

Not checked

– Logged Measurements Failed Cell

– Cell ID

Cell 1

– Primary CCPCH RSCP

(0..91)

– Logged Measurements Inter-RAT Neighbour cells list

– Logged Measurements E-UTRA frequency list

1 entry

– E-UTRA Carrier Frequency

Same as cell 2

– E-UTRA Carrier Frequency

65535

Band > 64

– Logged Measurements E-UTRA Frequency Neighbours List

1 entry

– Physical Cell Identity

Same as cell 2

– RSRP

(0..97)

– RSRQ

(0..34)

– Logged Measurements E-UTRA frequency extension list

1 entry

Band > 64

– EARFCN extension

Same as cell 2

8.6.5.2.5 Test requirements

At step 16, The UE shall send an UE INFORMATION RESPONSE message with Connection Establishment Failure Report on cell 1 and include the "Logged Measurements E-UTRA Frequency Neighbours List" with Cell 2 information in the Report. (TP1).

8.6.5.3 Connection Establishment Failure logging / Logging and reporting / GERAN Inter-RAT measurements

8.6.5.3.1 Definition

This test is applicable for all UEs that support Connection Establishment Failure logging services.

8.6.5.3.2 Conformance requirement

[TS 25.331, clause 8.1.3.6 (TP1)]

The UE shall compare the value of the IE "Initial UE identity" in the received RRC CONNECTION SETUP message with the value of the variable INITIAL_UE_IDENTITY.

If the values are different, the UE shall:

1> ignore the rest of the message.

If the values are identical, the UE shall:

1> submit an RRC CONNECTION SETUP COMPLETE message to the lower layers on the uplink DCCH after successful state transition per subclause 8.6.3.3, with the contents set as specified below:

2> if an IE "Logged Connection Establishment Failure Info-FDD" or "Logged Connection Establishment Failure Info-TDD" in variable LOGGED_CONNECTION_ESTABLISHMENT_FAILURE is present and the current Registered PLMN is the same as the PLMN in IE "PLMN Identity" stored in variable LOGGED_CONNECTION_ESTABLISHMENT_FAILURE:

3> include IE "Connection Establishment Failure Info Available".

When the RRC CONNECTION SETUP COMPLETE message has been submitted to lower layers for transmission the UE shall:

[TS 25.331, clause 8.1.3.10(TP1)]

If the UE receives an RRC CONNECTION REJECT message which contains an IE "Initial UE identity" with a value which is identical to the value of the IE "Initial UE identity" in the most recent RRC CONNECTION REQUEST message sent by the UE; but the RRC CONNECTION REJECT message contains a protocol error causing the variable PROTOCOL_ERROR_REJECT to be set to TRUE according to clause 9, the UE shall perform procedure specific error handling as follows:

The UE shall:

1> stop timer T300 or T318, whichever one is running; and

1> clear the entry for the RRC CONNECTION REJECT message in the table "Rejected transactions" in the variable TRANSACTIONS;

1> if V300 is equal to or smaller than N300:

2> set the variable PROTOCOL_ERROR_INDICATOR to TRUE;

2> set the IEs in the RRC CONNECTION REQUEST message according to subclause 8.1.3.3;

2> perform the mapping of the Access Class to an Access Service Class as specified in subclause 8.5.13, and apply the given Access Service Class when accessing the RACH or the common E-DCH (for the Enhanced Uplink in CELL_FACH and Idle mode);

2> submit a new RRC CONNECTION REQUEST message to the lower layers for transmission on the uplink CCCH;

2> increment counter V300;

2> restart timer T300 when the MAC layer indicates success or failure to transmit the message.

1> if V300 is greater than N300:

2> if the UE supports logging of failed RRC Connection Establishment, perform the actions specified in subclause 8.1.3.11;

2> enter idle mode;

2> perform the actions specified in subclause 8.5.2 when entering idle mode from connected mode;

2> consider the procedure to be successful;

2> the procedure ends.

[TS 25.331, clause 8.1.3.11 (TP1)]

If the RRC connection establishment fails and the UE supports logging of failed RRC Connection Establishment, the UE shall perform logging of information for later retrieval. The UE shall store connection establishment failure information in the variable LOGGED_CONNECTION_ESTABLISHMENT_FAILURE by setting its fields as follows:

1> clear the information included in the variable LOGGED_CONNECTION_ESTABLISHMENT_FAILURE, if any;

1> set the IE "PLMN Identity" to the same value as the selected PLMN [4];

1> set the IE "Number Of RRC Msg Transmitted" to indicate the number of times the RRC CONNECTION REQUEST message was transmitted by the UE during the failed RRC Connection Establishment procedure.

1> for TDD:

2> set the IE "FPACH Received" to TRUE if FPACH was received during the failed RRC Connection Establishment procedure.

2> if common E-DCH was used, include the IE "E-RUCCH Failure" and set it to TRUE if failure indication of the E-RUCCH transmission was received during the failed RRC Connection Establishment procedure.

1> set the IE "PLMN Identity" of the Logged Measurements Failed Cell to indicate the IE "PLMN Identity" obtained from system information of the cell where the connection establishment failure was detected;

1> set the IE "Cell ID" to indicate cell identity obtained from system information of the cell where the connection establishment failure was detected;

1> set the IE "CPICH Ec/N0" and "CPICH RSCP" to include measured quantities of the cell where the connection establishment failure was detected for UTRA FDD;

1> set the "P-CCPCH RSCP" to include measured quantities for the cell where the connection establishment failure was detected for UTRA 1.28 Mcps TDD;

1> set the IE "Logged Measurements Intra Frequency Neighbouring Cells list", "Logged Measurements Inter Frequency list", "Logged Measurements E-UTRA frequency list", "Logged Measurements E-UTRA frequency extension list", in order of decreasing ranking quantity as used for cell re-selection in each frequency for at most the following number of neighbouring cells; 6 intra-frequency and 3 inter-frequency neighbours per frequency as well as 3 inter-RAT neighbours, per frequency per RAT;

1> set the IE "Logged Measurements GSM Neighbouring Cells list" in order of decreasing RXLEV.

NOTE: The UE includes the latest available results of the measurement performed for cell reselection, which are performed in accordance with the regular performance requirements as specified in [19].

[TS 25.331, clause 8.5.64.3 (TP1)]

UE Shall:

1> if IE "Connection Establishment Failure Request" is present:

2> if Registered PLMN is the same as the PLMN in the IE "PLMN Identity" stored in variable LOGGED_CONNECTION_ESTABLISHMENT_FAILURE:

3> set IE "Connection Establishment Failure Report" in the UE INFORMATION RESPONSE as follows:

4> include the IE "Logged Connection Establishment Failure Info-FDD" or "Logged Connection Establishment Failure Info-TDD" and set it to include the entry from the variable LOGGED_CONNECTION_ESTABLISHMENT_FAILURE;

4> set the IE "Time Since Failure" to indicate the elapsed time starting from the Logging of the Connection establishment failure information that is stored in the variable LOGGED_CONNECTION_ESTABLISHMENT_FAILURE.

3> clear the variable LOGGED_CONNECTION_ESTABLISHMENT_FAILURE;

1> transmit a UE INFORMATION RESPONSE message on the uplink DCCH using AM RLC.

Reference

TS 25.304 clause 5.7 and TS 25.331 clause 8.3.1.6, 8.3.1.10, 8.1.3.11 and 8.5.64.3

.8.6.5.3.3 Test Purpose

1. Verify that GERAN neighbour cell information (IE "Logged Measurements GSM Neighbouring Cells list") is reported in connection establishment failure information in UE INFORMATION RESPONSE message.

8.6.5.3.4 Method of test

Initial conditions

System Simulator:

2 cells, Cell 1 (UTRAN) and Cell 9(GERAN)

User Equipment:

UE: Registered Idle mode (state 3) in Cell 1 as specified in clause 7.4 of TS 34.108.

Test procedure

Table 8.6.5.3-1 and table 8.6.5.3-2 illustrate the downlink power to be applied for the 3 cells at various time instants of the test execution. Columns marked "T0" denote the initial conditions, while column marked “T1” and “T2” is to be applied subsequently. The exact instants on which these values shall be applied are described in the texts in this clause.

Table 8.6.5.3-1

Parameter

Unit

Cell 1 (UTRA)

T0

T1

T2

UTRA RF Channel Number

Mid Range

Test Frequency

CPICH Ec(FDD)

dBm/3.84MHz

-60

-80

-60

PCCPCH_RSCP (TDD)

dBm

-60

-80

-60

Table 8.6.5.3-2

Parameter

Unit

Cell 9 (GSM)

T0

T1

T2

Test Channel

1

RF Signal Level

dBm

-90

-48

-90

RXLEV_ACCESS_MIN

dBm

-100

FDD_Qmin

dB

-20

FDD_Qoffset

dBm

0

The SS configures its downlink transmission power settings according to columns "T1" in tables 8.6.5.3-1 and 8.6.5.3-2. The UE performs cell re-selection to Cell 9 and performs RAU procedure.

The SS configures its downlink transmission power settings according to columns "T2" in tables 8.6.5.3-1 and 8.6.5.3-2. The UE performs cell re-selection to Cell 1 and performs RAU procedure.

The UE sends RRC CONNECTION REQUEST message to SS, and SS does not send any message to UE. Waits 2 seconds make T300 expire.

Repeats last procedure 3 times make V300>N300.

The SS sends Paging message to UE.

The UE transmits an RRC CONNECTION REQUEST message.

When the UE receives RRC CONNECTION SETUP message, the UE should transmit an RRC CONNECTION SETUP COMPLETE message including IE "Connection Establishment Failure Info Available".

The UE transmits SERVICE REQUEST message.

The SS sends an UE INFORMATION REQUEST message to get Connection Establishment Failure Report.

The UE shall send an UE INFORMATION RESPONSE message with Connection Establishment Failure Report on cell 1, include the “Logged Measurements GSM Neighbouring Cells list" with Cell 9 information in the Report.

The SS sends RRC CONNECTION RELEASE message to UE, and makes UE enter idle mode.

Expected sequence

Step

Direction

Message

Comments

UE

SS

1

SS

The SS switches its downlink transmission power settings to columns "T1" in tables 8.6.5.3-1 and 8.6.5.3-2.

2

à

CHANNEL REQUEST

The SS receives this burst on the RACH of cell 9(GSM cell). (triggered by UE RAU procedure)

3

ß

IMMEDIATE ASSIGNMENT

Sent on AGCH.

4

SS

The SS completes the RAU procedure requested by the UE.

5

ß

CHANNEL RELEASE

The SS transmits a channel release to return the UE to idle mode on Cell 9

6

SS

The SS switches its downlink transmission power settings to columns "T2" in tables 8.6.5.3-1 and 8.6.5.3-2.

7

à

RRC CONNECTION REQUEST

The SS waits for RRC CONNECTION REQUEST on CCCH from the UE on Cell 1 (triggered by UE RAU procedure).

8

ß

RRC CONNECTION SETUP

9

à

RRC CONNECTION SETUP COMPLETE

10

SS

The SS completes the RAU procedure requested by the UE.

11

ß

RRC CONNECTION RELEASE

12

à

RRC CONNECTION RELEASE COMPLETE

UE moves to IDLE mode state in Cell 1.

13

<–

Paging

SS transmits a Paging message.

14

–>

RRC CONNECTION REQUEST

The UE transmits an RRC CONNECTION REQUEST message.

15

SS does not send any message to UE. Waits 2 seconds make T300 expire.

16

Repeats “step 14 and step 15” 3 times make V300>N300.

17

Waiting 5 seconds allows UE to enter idle mode and perform Connection Establishment Failure logging

18

<–

Paging

SS transmits a Paging message.

19

–>

RRC CONNECTION REQUEST

The UE transmits an RRC CONNECTION REQUEST message.

20

<–

RRC CONNECTION SETUP

SS transmit an RRC CONNECTION SETUP message.

21

–>

RRC CONNECTION SETUP COMPLETE

The UE shall transmit an RRC CONNECTION SETUP COMPLETE message including IE "Connection Establishment Failure Info Available".

22

–>

RRC: INITIAL DIRECT TRANSFER

NAS: SERVICE REQUEST

The UE transmits SERVICE REQUEST message.

23

<–

UE INFORMATION REQUEST

SS sends an UE INFORMATION REQUEST message to get Connection Establishment Failure Report.

24

–>

UE INFORMATION RESPONSE

The UE shall send an UE INFORMATION RESPONSE message with Connection Establishment Failure Report on cell 1.

25

<–

RRC CONNECTION RELEASE

SS transmits a RRC CONNECTION RELEASE message to release RRC connection and moves to idle mode.

26

–>

RRC CONNECTION RELEASE COMPLETE

UE confirms the connection release and returns to Idle mode

Specific message contents

All messages have the same content as defined in 34.108 clause 9 with the following exceptions:

SYSTEM INFORMATION TYPE 1 (Initial conditions and all steps)

– UE Timers and constants in idle mode

-T300

2000 milliseconds

-N300

3

-T312

10 seconds

– N312

1

SYSTEM INFORMATION BLOCK TYPE 11 (Initial conditions and all steps)

Use same message sub-clause 6.1 of TS 34.108, with the exception of that Cell 9 is listed in the Inter-RAT cell id.

RRC CONNECTION SETUP COMPLETE (step 21)

Information Element

Value/remark

Message Type

RRC transaction identifier

The value of this IE is checked to see that it matches the value of the same IE transmitted in the downlink RRC CONNECTION SETUP message.

Connection Establishment Failure Info Available

TRUE

UE INFORMATION REQUEST (Step 23)

Information Element

Value/remark

Message Type

RRC transaction identifier

Arbitrarily selects an integer between 0 and 3

Integrity check info

– message authentication code

SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I.

– RRC message sequence number

SS provides the value of this IE, from its internal counter.

Logged Measurements Report Request

Not Present

Logged ANR Report Request

Not Present

Connection Establishment Failure Request

TRUE

UE INFORMATION RESPONSE (FDD) (Step 24)

Information Element

Value/remark

Message Type

RRC transaction identifier

Arbitrarily selects an integer between 0 and 3

Integrity check info

– message authentication code

SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I.

– RRC message sequence number

SS provides the value of this IE, from its internal counter.

Connection Establishment Failure Report

– Time Since Failure

[0…172800] Indicates the elapsed time in seconds between Logging and reporting of Connection establishment failure info.

– CHOICE mode

FDD

– Logged Connection Establishment Failure Info-FDD

– Number Of RRC Msg Transmitted

4

– Logged Measurements Failed Cell

– Cell ID

Cell 1

– CPICH RSCP

(0..91)

– CPICH Ec/N0

(0..49)

– Logged Measurements Inter-RAT Neighbour cells list

1 entry

– Logged Measurements GSM Neighbouring Cells list

1 entry

– BSIC

Same as Cell 9

– Band indicator

Same as Cell 9

– BCCH ARFCN

Same as Cell 9

– GSM carrier RSSI

(0…63)

UE INFORMATION RESPONSE (TDD) (Step 24)

Information Element

Value/remark

Message Type

RRC transaction identifier

Arbitrarily selects an integer between 0 and 3

Integrity check info

– message authentication code

SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I.

– RRC message sequence number

SS provides the value of this IE, from its internal counter.

Connection Establishment Failure Report

– Time Since Failure

[0…172800] Indicates the elapsed time in seconds between Logging and reporting of Connection establishment failure info.

– CHOICE mode

TDD

– Logged Connection Establishment Failure Info-TDD

– Number Of RRC Msg Transmitted

4

– FPACH Received

Not checked

– E-RUCCH Failure

Not checked

– Logged Measurements Failed Cell

– Cell ID

Cell 1

– Primary CCPCH RSCP

(0..91)

– Logged Measurements Inter-RAT Neighbour cells list

– Logged Measurements GSM Neighbouring Cells list

1 entry

– BSIC

Same as Cell 9

– Band indicator

Same as Cell 9

– BCCH ARFCN

Same as Cell 9

– GSM carrier RSSI

(0…63)

8.6.5.3.5 Test requirements

At step 24, The UE shall send an UE INFORMATION RESPONSE message with Connection Establishment Failure Report on cell 1 and include the “Logged Measurements GSM Neighbouring Cells list” with Cell 9 information in the Report. (TP1).