8.6.3 Inter-RAT Logged MDT
34.123-13GPPPart 1: Protocol conformance specificationRelease 15TSUser Equipment (UE) conformance specification
8.6.3.1 Logged MDT / E-UTRAN Inter-RAT measurement, logging and reporting / Idle mode
8.6.3.1.1 Definition
8.6.3.1.2 Conformance requirement
[TS 25.304, clause 5.7 (TP1)]
The UE may be configured to perform logging of measurement results in idle mode, CELL_PCH and URA_PCH state with LOGGING MEASUREMENT CONFIGURATION message specified in TS 25.331 [4]. This configuration is valid while the logging duration timer is running.
If the configuration of logged measurements is valid, the UE shall perform logging of measurement results if all of the following conditions are met:
– the UE is in camped normally state in idle mode, CELL_PCH or URA_PCH state;
– RPLMN of the UE is the same as the RPLMN at the point of time of LOGGING MEASUREMENT CONFIGURATION message reception
– the UE is camped on a cell belonging to Area Configuration (see TS 25.331 [4]), if configured;
– the UE is camped on the RAT where the logged measurement configuration was received.
Otherwise, the logging of measurement results shall be suspended.
NOTE: Even if logging of measurement results is suspended, the logging duration timer and time stamp will continue, and the logged measurement configuration and corresponding log are kept.
[TS 25.331, clause 8.5.64.3 (TP1)]
UE Shall:
1> if IE "Logged Measurements Report Request" is present:
2> if Registered PLMN is the same as the IE "PLMN Identity" stored in variable LOGGED_MEAS_REPORT_VARIABLE:
3> if an IE "Logged Measurement Info-FDD" or "Logged Measurement Info-TDD" in variable LOGGED_MEAS_REPORT_VARIABLE is present:
- set IE "Logged Meas Report" in the UE INFORMATION RESPONSE as follows:
5> include the IE "Absolute Time Info" and set it to the value of the IE "Absolute Time Info" in the variable LOGGED_MEAS_REPORT_VARIABLE;
5> include the IE "Trace reference" and set it to the value of IE "Trace reference" in the variable LOGGED_MEAS_REPORT_VARIABLE;
5> include the IE "Trace recording session" and set it to the value of IE "Trace recording session" in the variable LOGGED_MEAS_REPORT_VARIABLE;
5> include the IE "TCE Id" and set it to the value of IE "TCE Id" in the variable LOGGED_MEAS_REPORT_VARIABLE;
5> include the IEs "Logged Measurement Info-FDD" or "Logged Measurement Info-TDD" and set it to include, in the same order as logged, one or more entries from LOGGED_MEAS_REPORT_VARIABLE;
5> clear the logged measurement results included in the list of IEs "Logged Measurement Info-FDD" or "Logged Measurement Info-TDD" from LOGGED_MEAS_REPORT_VARIABLE;
5> if the variable LOGGED_MEAS_REPORT_VARIABLE is not empty:
6> include IE "Logged Meas Available";
2> transmit a UE INFORMATION RESPONSE message on the uplink DCCH using AM RLC.
1> if IE "Logged ANR Report Request" is present:
2> if Registered PLMN is the same as the IE "PLMN Identity" stored in variable LOG_ANR_REPORT_VARIABLE:
3> if IE "Logged ANR Report Info" in variable LOG_ANR_REPORT_VARIABLE is present:
4> set IEs "Logged ANR Report Info" in the UE INFORMATION RESPONSE as follows:
5> include the IEs "Logged ANR Report Info List" and set it to include entries from LOG_ANR_REPORT_VARIABLE;
5> clear the logged measurement results included in the list of IEs "Logged ANR Report Info List" from the LOG_ANR_REPORT_VARIABLE;
5> clear the variable LOG_ANR_CONFIG and stop timer T327.
2> transmit a UE INFORMATION RESPONSE message on the uplink DCCH using AM RLC.
[TS 25.331, clause 8.5.65 (TP1)]
When in idle mode, CELL_PCH or URA_PCH state and Logged Measurements has been configured, the UE shall:
1> Store the available measurements according to the logged measurements configuration in LOGGED_MEAS_CONFIG variable as specified in subclause 8.5.65.2.
[TS 25.331, clause 8.5.65.2 (TP1)]
While T326 is running, the UE shall:
1> perform this logging in accordance with the following:
2> perform the logging while camping normally on an UTRA cell and the RPLMN of the UE is the same as the PLMN Identity stored in LOGGED_MEAS_REPORT_VARIABLE and, if the IE "Area Configuration" is present in variable LOGGED_MEAS_CONFIG, that is part of the concerned area;
2> perform the logging at regular intervals, as defined by the IE "Logging Interval" in variable LOGGED_MEAS_CONFIG;
2> when adding a logged measurement entry in variable LOGGED_MEAS_REPORT_VARIABLE, include the fields in accordance with the following:
3> set the IE "Relative Time Stamp" to indicate time relative to the moment at which the logged measurement configuration was received;
3> if GNSS location information became available during the last logging interval:
4> if the UE has been able to calculate a 3-dimensional position:
5> set IE "Ellipsoid point with altitude" to include the location coordinates;
4>else:
5> set IE "Ellipsoid point" to include the location coordinates:
3> set the IE "Cell ID" to indicate cell identity of the cell the UE is camping on obtained from system information;
3> set the IE "CPICH Ec/N0" and "CPICH RSCP" to include measured quantities of the cell that the UE is camping on for UTRA FDD;
3> set the "P-CCPCH RSCP" to include measured quantities for the cell that the UE is camping on for UTRA 1.28 Mcps TDD;
3> set the IE "Logged Measurements Intra Frequency Neighbouring Cells list", "Logged Measurements Inter Frequency list", "Logged Measurements E-UTRA frequency list", in order of decreasing ranking quantity as used for cell re-selection in each frequency for at most the following number of neighbouring cells; 6 intra-frequency and 3 inter-frequency neighbours per frequency as well as 3 inter-RAT neighbours, per frequency per RAT;
3> set the IE "Logged Measurements GSM Neighbouring Cells list" in order of decreasing RXLEV.
NOTE: The UE includes, only once, the latest available results of the measurement performed for cell reselection, which are performed in accordance with the regular performance requirements as specified in [19].
2> when the memory reserved for the logging of measurements becomes full, stop timer T326 and performs the same actions as performed upon expiry of T326, as specified in 8.5.63.4.
Reference
TS 25.304 clause 5.7, TS 25.331 clauses 8.5.64., 8.5.65 and 8.5.65.2.
8.6.3.1.3 Test Purpose
1. Verify logging and reporting of Logged MDT E-UTRAN Inter-RAT measurements
8.6.3.1.4 Method of test
System Simulator: 1 UTRAN FDD cell (or TDD cell) and 1 E-UTRAN cell. Cell 1 is a UTRAN cell, and Cell 2 is an E-UTRAN Cell. Cell 2 configuration refers to “Cell 1” in TS36.508 clause 6.3. SIB configuration 6 is applied in accordance with TS 34.108 clause 6.1.0a.2.
UE: PS-DCCH+DTCH_DCH (state 6-10) in Cell 1as specified in clause 7.4 of TS 34.108.
Related ICS/IXIT statements
– Compressed mode required yes/no
– UE supports E-UTRAN.
Test Procedure
Table 8.6.3.1illustrates the downlink power to be applied for the 2 cells at various time instants of the test execution. Column marked "T0" denotes the initial condition, while column marked "T1" and "T2" is to be applied subsequently. The exact instants on which these values shall be applied are described in the texts in this clause.
Table 8.6.3.1: Time instances of cell power level and parameter changes
Parameter |
Unit |
Cell 1(UTRA) |
Cell 2(E-UTRA) |
|
T0 |
Cell-specific RS EPRE |
dBm/15kHz |
– |
-90 |
CPICH Ec (UTRA FDD) |
dBm/3.84 MHz |
-65 |
– |
|
PCCPCH Ec(UTRA LCR TDD) |
dBm/1.28 MHz |
-65 |
– |
|
T1 |
Cell-specific RS EPRE |
dBm/15kHz |
– |
-70 |
CPICH Ec (UTRA FDD) |
dBm/3.84 MHz |
-100 |
– |
|
PCCPCH Ec(UTRA LCR TDD) |
dBm/1.28 MHz |
-100 |
– |
|
T2 |
Cell-specific RS EPRE |
dBm/15kHz |
– |
-90 |
CPICH Ec (UTRA FDD) |
dBm/3.84 MHz |
-65 |
– |
|
PCCPCH Ec(UTRA LCR TDD) |
dBm/1.28 MHz |
-65 |
– |
The UE is in CELL_DCH state of cell 1. SS transmits a LOGGING MEASUREMENT CONFIGURATION message to the UE to configure logged measurements.
SS transmits an RRC CONNECTION RELEASE message to the UE to disconnect the connection.
The UE transmits an RRC CONNECTION RELEASE COMPLETE message using unacknowledged mode
Wait 10s to allow UE to activate logging.
SS applies the downlink transmission power settings, according to the values in columns "T1" of table 8.6.3.1. The UE shall find that the cell 2 is better and attempt to perform a cell reselection.
UE reselects to cell 2 and moves to RRC_IDLE.
SS applies the downlink transmission power settings, according to the values in columns "T2" of table 8.6.3.1. The UE shall find that the cell 1 is better and attempt to perform a cell reselection.
The UE transmits an RRC CONNECTION REQUEST message to SS.
SS transmits an RRC CONNECTION SETUP message to the UE.
The UE transmits an RRC CONNECTION SETUP COMPLETE message to SS, and enters CELL_DCH state.
The UE performs RAU procedure on Cell 1.
SS transmits a UE INFORMATION REQUEST message, and the IE "Logged Measurements Report Request" is present.
The UE shall transmit a UE INFORMATION REPONSE message, with IE "Logged Measurement Info-FDD" or "Logged Measurement Info-TDD". And Logged Measurements of Cell 2 is in the Logged Measurements inter RAT Neighbouring Cells list”.
SS transmits an RRC CONNECTION RELEASE message to the UE to disconnect the connection.
The UE transmits an RRC CONNECTION RELEASE COMPLETE message using unacknowledged mode
Expected Sequence
Step |
Direction |
Message |
Comment |
|
---|---|---|---|---|
UE |
SS |
|||
1 |
ß |
LOGGING MEASUREMENT CONFIGURATION |
Include IE “Logged Measurements Configuration Info”, with “Logging Interval” set as 2.56s and “Logging Duration” set as 10min. |
|
2 |
ß |
RRC CONNECTION RELEASE |
||
3 |
à |
RRC CONNECTION RELEASE COMPLETE |
The UE sends this message before it completes state transition. |
|
4 |
– |
– |
Wait 10s to allow UE to activate logging. |
|
5 |
– |
– |
SS applies the downlink transmission power settings, according to the values in columns "T1" of table 8.6.3.1. The UE shall find that the cell 2 is better and attempt to perform a cell reselection. |
|
6 |
– |
– |
Call generic procedure in 36.508 subclause 6.4.2.7A-1, UE reselects to cell 2. The UE performs a TAU procedure and the RRC Connection is released. |
|
7 |
– |
– |
SS applies the downlink transmission power settings, according to the values in columns "T2" of table 8.6.3.1. The UE shall find that the cell 1 is better and attempt to perform a cell reselection. |
|
10 |
à |
RRC CONNECTION REQUEST |
||
11 |
ß |
RRC CONNECTION SETUP |
||
12 |
à |
RRC CONNECTION SETUP COMPLETE |
||
13 |
– |
– |
Call steps 4 to 8 in generic procedure in 36.508 subclause 6.4.2.8-1, the UE performs a RAU procedure on Cell 1. |
|
14 |
ß |
UE INFORMATION REQUEST |
SS transmits a UE INFORMATION REQUEST message with IE "Logged Measurements Report Request" set to “true”. |
|
15 |
à |
UE INFORMATION RESPONSE |
The UE shall send a UE INFORMATION RESPONSE message. And Logged Measurements of Cell 2 is in the Logged Measurements E-UTRA frequency list. |
|
16 |
ß |
RRC CONNECTION RELEASE |
||
17 |
à |
RRC CONNECTION RELEASE COMPLETE |
The UE sends this message before it completes state transition. |
Specific Message Contents
Conditions for specific message contents
Condition |
Explanation |
Band > 64 |
If E-UTRA band > 64 is selected |
LOGGING MEASUREMENT CONFIGURATION (Step 1)
Information Element |
Value/remark |
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged ANR configuration Info |
|
– Absolute Time Info |
Set to value corresponding to the absolute time when the message is sent |
– Logging Duration |
10 min |
– Logging Interval |
|
– Trace reference |
|
– PLMN Identity |
Same as MIB |
– Trace ID |
‘0EF’H |
-Trace recording session |
‘1A’H |
– TCE Id |
‘5’H |
– CHOICE Area Configuration |
Not present |
UE INFORMATION REQUEST (Step 14)
Information Element |
Value/remark |
---|---|
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Measurements Report Request |
TRUE |
Logged ANR Report Request |
Not Present |
UE INFORMATION RESPONSE (FDD) (Step 15)
Information Element |
Value/remark |
Conditions |
---|---|---|
Message Type |
||
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
|
Integrity check info |
||
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
|
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
|
Logged Meas Report |
||
– Absolute Time Info |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
|
– Trace reference |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
|
– PLMN Identity |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
|
– Trace ID |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
|
– Trace recording session |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
|
– TCE Id |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
|
– CHOICE mode |
FDD |
|
– List of measurements FDD |
At least 1 entry where at least one entry complies to entry with index ‘x’ below. |
|
– Logged Measurement Info-FDD[x] |
||
– Relative Time Stamp[x] |
Not checked |
|
– Logged Measurements Serving Cell[x] |
||
– Cell ID[x] |
Cell 1 |
|
– Primary CCPCH RSCP[x] |
(0..91) |
|
– CPICH Ec/N0 |
(0..49) |
|
– Logged Measurements Inter-RAT Neighbour cells list [x] |
||
– Logged Measurements E-UTRA frequency list |
1 entry |
|
– E-UTRA Carrier Frequency |
Same as cell 2 |
|
– E-UTRA Carrier Frequency |
65535 |
Band > 64 |
– Logged Measurements E-UTRA Frequency Neighbours List |
1 entry |
|
– Physical Cell Identity |
Same as cell 2 |
|
– RSRP |
(0..97) |
|
– RSRQ |
(0..34) |
|
– Logged Measurements E-UTRA frequency extension list |
1 entry |
Band > 64 |
– EARFCN extension |
Same as cell 2 |
|
– Logged Meas Available |
Not checked |
UE INFORMATION RESPONSE (TDD) (Step 15)
Information Element |
Value/remark |
Conditions |
---|---|---|
Message Type |
||
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
|
Integrity check info |
||
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
|
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
|
Logged Meas Report |
||
– Absolute Time Info |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
|
– Trace reference |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
|
– PLMN Identity |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
|
– Trace ID |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
|
– Trace recording session |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
|
– TCE Id |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
|
– CHOICE mode |
TDD |
|
– List of measurements TDD |
At least 1 entry where at least one entry complies to entry with index ‘x’ below. |
|
– Logged Measurement Info-TDD[x] |
||
– Relative Time Stamp[x] |
Not checked |
|
– Logged Measurements Serving Cell[x] |
||
– Cell ID |
Cell 1 |
|
– Primary CCPCH RSCP |
(0..91) |
|
– Logged Measurements Inter-RAT Neighbour cells list |
||
– Logged Measurements E-UTRA frequency list |
1 entry |
|
– E-UTRA Carrier Frequency |
Same as cell 2 |
|
– E-UTRA Carrier Frequency |
65535 |
Band > 64 |
– Logged Measurements E-UTRA Frequency Neighbours List |
1 entry |
|
– Physical Cell Identity |
Same as cell 2 |
|
– RSRP |
(0..97) |
|
– RSRQ |
(0..34) |
|
– Logged Measurements E-UTRA frequency extension list |
1 entry |
Band > 64 |
– EARFCN extension |
Same as cell 2 |
|
– Logged Meas Available |
Not checked |
8.6.3.1.5 Test requirement
At step 15, the UE shall transmit a UE INFORMATION RESPONSE message, with IE “Logged Measurements Inter-RAT Neighbour cells list” include Logged Measurements of Cell 2 (TP1).
8.6.3.2 Logged MDT / GERAN Inter-RAT measurement, logging and reporting / Idle mode
8.6.3.2.1 Definition
8.6.3.2.2 Conformance requirement
[TS 25.304, clause 5.7 (TP1)]
The UE may be configured to perform logging of measurement results in idle mode, CELL_PCH and URA_PCH state with LOGGING MEASUREMENT CONFIGURATION message specified in TS 25.331 [4]. This configuration is valid while the logging duration timer is running.
If the configuration of logged measurements is valid, the UE shall perform logging of measurement results if all of the following conditions are met:
– the UE is in camped normally state in idle mode, CELL_PCH or URA_PCH state;
– RPLMN of the UE is the same as the RPLMN at the point of time of LOGGING MEASUREMENT CONFIGURATION message reception
– the UE is camped on a cell belonging to Area Configuration (see TS 25.331 [4]), if configured;
– the UE is camped on the RAT where the logged measurement configuration was received.
Otherwise, the logging of measurement results shall be suspended.
NOTE: Even if logging of measurement results is suspended, the logging duration timer and time stamp will continue, and the logged measurement configuration and corresponding log are kept.
[TS 25.331, clause 8.5.65.2 (TP1)]
While T326 is running, the UE shall:
1> perform this logging in accordance with the following:
2> perform the logging while camping normally on an UTRA cell and the RPLMN of the UE is the same as the PLMN Identity stored in LOGGED_MEAS_REPORT_VARIABLE and, if the IE "Area Configuration" is present in variable LOGGED_MEAS_CONFIG, that is part of the concerned area;
2> perform the logging at regular intervals, as defined by the IE "Logging Interval" in variable LOGGED_MEAS_CONFIG;
2> when adding a logged measurement entry in variable LOGGED_MEAS_REPORT_VARIABLE, include the fields in accordance with the following:
3> set the IE "Relative Time Stamp" to indicate time relative to the moment at which the logged measurement configuration was received;
3> if GNSS location information became available during the last logging interval:
4> if the UE has been able to calculate a 3-dimensional position:
5> set IE "Ellipsoid point with altitude" to include the location coordinates;
4> else:
5> set IE "Ellipsoid point" to include the location coordinates:
3> set the IE "Cell ID" to indicate cell identity of the cell the UE is camping on obtained from system information;
3> set the IE "CPICH Ec/N0" and "CPICH RSCP" to include measured quantities of the cell that the UE is camping on for UTRA FDD;
3> set the "P-CCPCH RSCP" to include measured quantities for the cell that the UE is camping on for UTRA 1.28 Mcps TDD;
3> set the IE "Logged Measurements Intra Frequency Neighbouring Cells list", "Logged Measurements Inter Frequency list", "Logged Measurements E-UTRA frequency list", in order of decreasing ranking quantity as used for cell re-selection in each frequency for at most the following number of neighbouring cells; 6 intra-frequency and 3 inter-frequency neighbours per frequency as well as 3 inter-RAT neighbours, per frequency per RAT;
3> set the IE "Logged Measurements GSM Neighbouring Cells list" in order of decreasing RXLEV.
NOTE: The UE includes, only once, the latest available results of the measurement performed for cell reselection, which are performed in accordance with the regular performance requirements as specified in [19].
2> when the memory reserved for the logging of measurements becomes full, stop timer T326 and performs the same actions as performed upon expiry of T326, as specified in 8.5.63.4.
[TS 25.331, clause 8.5.64.3 (TP1)]
UE Shall:
1> if IE "Logged Measurements Report Request" is present:
2> if Registered PLMN is the same as the IE "PLMN Identity" stored in variable LOGGED_MEAS_REPORT_VARIABLE:
3> if an IE "Logged Measurement Info-FDD" or "Logged Measurement Info-TDD" in variable LOGGED_MEAS_REPORT_VARIABLE is present:
- set IE "Logged Meas Report" in the UE INFORMATION RESPONSE as follows:
5> include the IE "Absolute Time Info" and set it to the value of the IE "Absolute Time Info" in the variable LOGGED_MEAS_REPORT_VARIABLE;
5> include the IE "Trace reference" and set it to the value of IE "Trace reference" in the variable LOGGED_MEAS_REPORT_VARIABLE;
5> include the IE "Trace recording session" and set it to the value of IE "Trace recording session" in the variable LOGGED_MEAS_REPORT_VARIABLE;
5> include the IE "TCE Id" and set it to the value of IE "TCE Id" in the variable LOGGED_MEAS_REPORT_VARIABLE;
5> include the IEs "Logged Measurement Info-FDD" or "Logged Measurement Info-TDD" and set it to include, in the same order as logged, one or more entries from LOGGED_MEAS_REPORT_VARIABLE;
5> clear the logged measurement results included in the list of IEs "Logged Measurement Info-FDD" or "Logged Measurement Info-TDD" from LOGGED_MEAS_REPORT_VARIABLE;
5> if the variable LOGGED_MEAS_REPORT_VARIABLE is not empty:
6> include IE "Logged Meas Available";
2> transmit a UE INFORMATION RESPONSE message on the uplink DCCH using AM RLC.
1> if IE "Logged ANR Report Request" is present:
2> if Registered PLMN is the same as the IE "PLMN Identity" stored in variable LOG_ANR_REPORT_VARIABLE:
3> if IE "Logged ANR Report Info" in variable LOG_ANR_REPORT_VARIABLE is present:
4> set IEs "Logged ANR Report Info" in the UE INFORMATION RESPONSE as follows:
5> include the IEs "Logged ANR Report Info List" and set it to include entries from LOG_ANR_REPORT_VARIABLE;
5> clear the logged measurement results included in the list of IEs "Logged ANR Report Info List" from the LOG_ANR_REPORT_VARIABLE;
5> clear the variable LOG_ANR_CONFIG and stop timer T327.
2> transmit a UE INFORMATION RESPONSE message on the uplink DCCH using AM RLC.
[TS 37.320, clause 5.1.1.3.1 (TP1)]
A UE configured to perform Logged MDT measurements indicates the availability of Logged MDT measurements, by means of an indicator, in RRCConnectionSetupComplete message during connection establishment. Furthermore, the indicator (possibly updated) shall be provided within E-UTRAN handover and re-establishment, and UTRAN procedures involving the change of SRNC (SRNC relocation), CELL UPDATE, URA UPDATE messages as well as MEASUREMENT REPORT message in case of state transition to CELL_FACH without CELL UPDATE. The UE includes the indication in one of these messages at every transition to RRC Connected mode even though the logging period has not ended, upon connection to RAT which configured the UE to perform Logged MDT measurements and RPLMN which is equal to a PLMN in the MDT PLMN list.
The indicator shall be also provided in UEInformationResponse message during MDT report retrieval in case the UE has not transferred the total log in one RRC message in order to indicate the remaining data availability.
The UE will not indicate the availability of MDT measurements in another RAT or in a PLMN that is not in the MDT PLMN list.
The network may decide to retrieve the logged measurements based on this indication. In case Logged MDT measurements are retrieved before the completion of the pre-defined logging duration, the reported measurement results are deleted, but MDT measurement logging will continue according to ongoing logged measurement configuration.
In case the network does not retrieve Logged MDT measurements, UE should store non-retrieved measurements for 48 hours from the moment the duration timer for logging expired. There is no requirement to store non-retrieved data beyond 48 hours. In addition, all logged measurement configuration and the log shall be removed by the UE at switch off or detach.
Reference
TS 25.304 clause 5.7, TS 25.331 clauses 8.5.65.2, 8.5.64.3 and TS37.320 clause 5.1.1.3.1.
8.6.3.2.3 Test Purpose
1. Verify logging and reporting of Logged MDT GERAN Inter-RAT measurements
8.6.3.2.4 Method of test
Initial Condition
System Simulator: 2 cells – cell 1 and cell 9 are active. Cell 1 is UTRA FDD or TDD cells. Cell 9 is GSM cell. The PLMN of Cell 1 and Cell 9 are the same.
UE: PS-DCCH+DTCH_DCH (state 6-10) in cell 1 as specified in clause 7.4 of TS 34.108.
Test Procedure
Table 8.6.3.2-1and Table 8.6.3.2-2 illustrates the downlink power levels and other changing parameters to be applied for the cells at various time instants of the test execution. Row marked "T0" denotes the initial conditions after preamble, while columns marked "T1" is to be applied subsequently.
Table 8.6.3.2-1: Time instances of cell power level and parameter changes
Parameter |
Unit |
Cell 1 |
||
T0 |
T1 |
T2 |
||
UTRA RF Channel Number |
Mid Range Test Frequency |
|||
CPICH Ec |
dBm/3.84MHz |
-60 |
-80 |
-60 |
PCCPCH_RSCP (TDD) |
dBm |
-60 |
-80 |
-60 |
Table 8.6.3.2-2
Parameter |
Unit |
Cell 9 (GSM) |
||
T0 |
T1 |
T2 |
||
Test Channel |
1 |
|||
RF Signal Level |
dBm |
-90 |
-48 |
-90 |
RXLEV_ACCESS_MIN |
dBm |
-100 |
-100 |
-100 |
FDD_Qmin |
dB |
-20 |
-20 |
-20 |
FDD_Qoffset |
dBm |
0 |
0 |
0 |
The UE is in CELL_DCH state of cell 1. SS transmits a LOGGING MEASUREMENT CONFIGURATION message to the UE to configure logged measurements.
SS transmits an RRC CONNECTION RELEASE message to the UE to disconnect the connection.
The UE transmits an RRC CONNECTION RELEASE COMPLETE message using unacknowledged mode
Wait 10s to allow UE to activate logging.
SS applies the downlink transmission power settings, according to the values in columns "T1" of table 8.6.3.2-1 and table 8.6.3.2-2. The UE shall find that the cell 9 is better and attempt to perform a cell reselection.
UE reselects to GERAN cell 9 and complete routing area update procedure on cell 9.
SS applies the downlink transmission power settings, according to the values in columns "T2" of table 8.6.3.2-1 and table 8.6.3.2-2. The UE shall find that the cell 1 is better and attempt to perform a cell reselection.
The UE transmits an RRC CONNECTION REQUEST message to SS.
SS transmits an RRC CONNECTION SETUP message to the UE.
The UE transmits an RRC CONNECTION SETUP COMPLETE message to SS, and enters CELL_DCH state.
SS completes routing area update procedure on cell 1.
SS transmits a UE INFORMATION REQUEST message, and the IE "Logged Measurements Report Request" is present.
The UE shall transmit a UE INFORMATION REPONSE message, with IE "Logged Measurement Info-FDD" or "Logged Measurement Info-TDD". And Logged Measurements of Cell 9 is in the Logged Measurements inter RAT Neighbouring Cells list”.
Expected Sequence
Step |
Direction |
Message |
Comment |
|
---|---|---|---|---|
UE |
SS |
|||
1 |
ß |
LOGGING MEASUREMENT CONFIGURATION |
Include IE “Logged Measurements Configuration Info”, with “Logging Interval” set as 2.56s and “Logging Duration” set as 10min. |
|
2 |
ß |
RRC CONNECTION RELEASE |
||
3 |
à |
RRC CONNECTION RELEASE COMPLETE |
The UE sends this message before it completes state transition. |
|
4 |
Wait 10s to allow UE to activate logging. |
|||
5 |
– |
– |
SS applies the downlink transmission power settings, according to the values in columns "T1" of table 8.6.3.2-1 and table 8.6.3.2-2. The UE shall find that the cell 9 is better and attempt to perform a cell reselection. |
|
6 |
|
CHANNEL REQUEST |
The SS receives this burst on the RACH of cell 9(GSM cell). (triggered by UE routing area update procedure) |
|
7 |
|
IMMEDIATE ASSIGNMENT |
Sent on AGCH. |
|
8 |
SS |
The SS completes the routing area update procedure requested by the UE. |
||
9 |
– |
– |
SS applies the downlink transmission power settings, according to the values in columns "T2" of table 8.6.3.2-1 and table 8.6.3.2-2. The UE shall find that the cell 1 is better and attempt to perform a cell reselection. |
|
10 |
à |
RRC CONNECTION REQUEST |
||
11 |
ß |
RRC CONNECTION SETUP |
||
12 |
à |
RRC CONNECTION SETUP COMPLETE |
||
13 |
– |
– |
The SS completes the Routing Area Update procedure requested by the UE. |
|
14 |
ß |
UE INFORMATION REQUEST |
SS transmits a UE INFORMATION REQUEST message with IE "Logged Measurements Report Request" set to “true”. |
|
15 |
à |
UE INFORMATION RESPONSE |
The UE shall send a UE INFORMATION RESPONSE message. And Logged Measurements of Cell 9 is in the Logged Measurements GSM frequency list. |
Specific Message Contents
LOGGING MEASUREMENT CONFIGURATION (Step 1)
Information Element |
Value/remark |
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged ANR configuration Info |
|
– Absolute Time Info |
Set to value corresponding to the absolute time when the message is sent |
– Logging Duration |
10 min |
– Logging Interval |
|
– Trace reference |
|
– PLMN Identity |
Same as MIB |
– Trace ID |
‘0EF’H |
-Trace recording session |
‘1A’H |
– TCE Id |
‘5’H |
– CHOICE Area Configuration |
Not present |
UE INFORMATION REQUEST (Step 14)
Information Element |
Value/remark |
---|---|
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Measurements Report Request |
TRUE |
Logged ANR Report Request |
Not Present |
UE INFORMATION RESPONSE (FDD) (Step 14)
Information Element |
Value/remark |
---|---|
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Meas Report |
|
– Absolute Time Info |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace reference |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– PLMN Identity |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace ID |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace recording session |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– TCE Id |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– CHOICE mode |
FDD |
– List of measurements FDD |
At least 1 entry where at least one entry complies to entry with index ‘x’ below. |
– Logged Measurement Info-FDD[x] |
|
– Relative Time Stamp[x] |
Not checked |
– Logged Measurements Serving Cell[x] |
|
– Cell ID[x] |
Cell 1 |
– Primary CCPCH RSCP[x] |
(0..91) |
– CPICH Ec/N0 |
(0..49) |
– Logged Measurements Inter-RAT Neighbour cells list |
|
– Logged Measurements GSM Neighbouring Cells list |
|
– BSIC |
Same as cell 9 |
– Band indicator |
Same as cell 9 |
– BCCH ARFCN |
Same as cell 9 |
– GSM carrier RSSI |
(0…63) |
– Logged Meas Available |
Not checked |
UE INFORMATION RESPONSE (TDD) (Step 15)
Information Element |
Value/remark |
---|---|
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Meas Report |
|
– Absolute Time Info |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace reference |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– PLMN Identity |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace ID |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace recording session |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– TCE Id |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– CHOICE mode |
TDD |
– List of measurements TDD |
At least 1 entry where at least one entry complies to entry with index ‘x’ below. |
– Logged Measurement Info-TDD[x] |
|
– Relative Time Stamp[x] |
Not checked |
– Logged Measurements Serving Cell[x] |
|
– Cell ID |
Cell 1 |
– Primary CCPCH RSCP |
(0..91) |
– Logged Measurements Inter-RAT Neighbour cells list |
|
– Logged Measurements GSM Neighbouring Cells list |
1 entry |
– BSIC |
Same as cell 9 |
– Band indicator |
Same as cell 9 |
– BCCH ARFCN |
Same as cell 9 |
– GSM carrier RSSI |
(0…63) |
– Logged Meas Available |
Not checked |
8.6.3.2.5 Test requirement
At step 15, the UE shall transmit a UE INFORMATION RESPONSE message, with IE “Logged Measurements Inter-RAT Neighbour cells list” include Logged Measurements of Cell 9 (TP1).
8.6.3.3 Logged MDT / Maintaining logged measurement configuration / UTRAN to E-UTRAN Inter-RAT mobility
8.6.3.3.1 Definition
8.6.3.3.2 Conformance requirement
[TS 25.304, clause 5.7 (TP1, TP2)]
The UE may be configured to perform logging of measurement results in idle mode, CELL_PCH and URA_PCH state with LOGGING MEASUREMENT CONFIGURATION message specified in TS 25.331 [4]. This configuration is valid while the logging duration timer is running.
If the configuration of logged measurements is valid, the UE shall perform logging of measurement results if all of the following conditions are met:
– the UE is in camped normally state in idle mode, CELL_PCH or URA_PCH state;
– RPLMN of the UE is the same as the RPLMN at the point of time of LOGGING MEASUREMENT CONFIGURATION message reception
– the UE is camped on a cell belonging to Area Configuration (see TS 25.331 [4]), if configured;
– the UE is camped on the RAT where the logged measurement configuration was received.
Otherwise, the logging of measurement results shall be suspended.
NOTE: Even if logging of measurement results is suspended, the logging duration timer and time stamp will continue, and the logged measurement configuration and corresponding log are kept.
[TS 25.331, clause 8.3.6.3 (TP1, TP2)]
The UE shall be able to receive a HANDOVER TO UTRAN COMMAND message and perform an inter-RAT handover, even if no prior UE measurements have been performed on the target UTRAN cell and/or frequency.
The UE shall act upon all received information elements as specified in subclause 8.6, unless specified otherwise in the following.
The UE may:
1> maintain a list of the set of cells to which the UE has Radio Links if the IE "Cell ID" is present.
The UE shall:
…
1> if an IE "Logged Measurement Info-FDD" or "Logged Measurement Info-TDD" in variable LOGGED_MEAS_REPORT_VARIABLE is present and registered PLMN is the same as the IE "PLMN Identity" stored in variable LOGGED_MEAS_REPORT_VARIABLE:
2> include IE "Logged Meas Available".
…
1> and the procedure ends.
[TS 25.331, clause 8.5.63.3 (TP1, TP2)]
Upon receiving the LOGGING MEASUREMENT CONFIGURATION message the UE shall:
1> if IE "Logged Measurements Configuration Info" is present:
2> if stored, discard the existing logged measurement configuration as well as the logged measurement information as specified in 8.5.66;
2> store the received IEs "Logging Duration", "Logging Interval", "Area Configuration" if included in IE "Logged Measurements Configuration Info" in variable LOGGED_MEAS_CONFIG and IEs "Absolute Time Info", "Trace reference", "Trace recording session" and "TCE Id" in variable LOGGED_MEAS_REPORT_VARIABLE;
2> store the current Registered PLMN in the IE "PLMN Identity" in variable LOGGED_MEAS_REPORT_VARIABLE;
2> start timer T326 with the timer value set to the IE "Logging Duration".
NOTE: The UE should not stop timer T326 unless explicitly stated when it moves to another RAT.
1> if IE "Logged ANR configuration Info" is present:
2> if variable LOG_ANR_CONFIG was already stored, discard the existing logged measurement configuration for ANR purpose as well as the associated logged measurement information as specified in 8.5.68;
2> store the received IEs in the IE "Logged ANR configuration Info" in variable LOG_ANR_CONFIG;
2> store the current Registered PLMN in the IE "PLMN Identity" in variable LOG_ANR_REPORT_VARIABLE;
2> store the list of Equivalent PLMNs in the IE "Equivalent PLMN Identity List" in variable LOG_ANR_REPORT_VARIABLE;
2> start timer T327 with the timer value set to the IE "Logging Duration" included in IE "Logged ANR configuration Info".
Reference
TS 25.304 clause 5.7, TS 25.331 clauses 8.5.6.3 and 8.5.63.3.
8.6.3.3.3 Test Purpose
1. Verify indication of availability of Logged MDT measurements in HANDOVER TO UTRAN COMMAND message.
2. Verify that logged measurement configurations and logs are maintained despite periods of interruptions due to UE transitions to E-UTRAN.
8.6.3.3.4 Method of test
System Simulator: 1 UTRAN FDD cell (or TDD cell) and 1 E-UTRAN cell. Cell 1 is a UTRAN cell, and Cell 2 is an E-UTRAN Cell. Cell 2 configuration refers to “Cell 1” in TS36.508 clause 6.3.
UE: PS-DCCH+DTCH_DCH (state 6-10) in Cell 1as specified in clause 7.4 of TS 34.108.
Related ICS/IXIT statements
– Compressed mode required yes/no
– UE supports E-UTRAN.
Test Procedure
Table 8.6.3.3 illustrates the downlink power to be applied for the 2 cells at various time instants of the test execution. Column marked "T0" denotes the initial condition. Subsequent configurations marked “T1”, “T2” are applied at the points indicated described in the texts in this clause.
T2 |
Cell-specific RS EPRE |
dBm/15kHz |
– |
-90 |
|
CPICH Ec (UTRA FDD) |
dBm/3.84 MHz |
-65 |
– |
||
PCCPCH Ec(UTRA LCR TDD) |
dBm/1.28 MHz |
-65 |
– |
Table 8.6.3.3: Time instances of cell power level and parameter changes
Parameter |
Unit |
Cell 1(UTRA) |
Cell 2(E-UTRA) |
Remark |
|
T0 |
Cell-specific RS EPRE |
dBm/15kHz |
– |
-90 |
|
CPICH Ec (UTRA FDD) |
dBm/3.84 MHz |
-65 |
– |
||
PCCPCH Ec(UTRA LCR TDD) |
dBm/1.28 MHz |
-65 |
– |
||
T1 |
Cell-specific RS EPRE |
dBm/15kHz |
– |
-70 |
The power level values are such that entering conditions for event 3a are satisfied. |
CPICH Ec (UTRA FDD) |
dBm/3.84 MHz |
-100 |
– |
||
PCCPCH Ec (UTRA LCR TDD) |
dBm/1.28 MHz |
-100 |
– |
||
T2 |
Cell-specific RS EPRE |
dBm/15kHz |
– |
-90 |
|
CPICH Ec (UTRA FDD) |
dBm/3.84 MHz |
-65 |
– |
||
PCCPCH Ec(UTRA LCR TDD) |
dBm/1.28 MHz |
-65 |
– |
The UE is in CELL_DCH state of cell 1. SS transmits a LOGGING MEASUREMENT CONFIGURATION message to the UE to configure logged measurements.
SS transmits an RRC CONNECTION RELEASE message to the UE to disconnect the connection.
The UE transmits an RRC CONNECTION RELEASE COMPLETE message using unacknowledged mode.
Wait 10s to allow UE to activate logging.
The UE transmits an RRC CONNECTION REQUEST message to SS.
SS transmits an RRC CONNECTION SETUP message to the UE.
The UE transmits an RRC CONNECTION SETUP COMPLETE message to SS, and enters CELL_DCH state.
The UE transmits SERVICE REQUEST message.
SS sends PHYSICAL CHANNEL RECONFIGURATION message to the UE to configure the compressed mode pattern sequence parameters. When the PHYSICAL CHANNEL RECONFIGURATION COMPLETE is received from the UE, the SS sends a MEASUREMENT CONTROL message.
SS adjusts cell power level according to columns "T1" in tables 8.6.3.3, and UE send MEASUREMENT REPORT to SS.
The UE receive “HANDOVER FROM UTRAN COMMAND” message from cell1, and handover to E-UTRAN cell 2,
SS adjust cell power level according to columns "T2" in tables 8.6.3.3, and UE sends MeasurementReport message to SS.
SS transmits a MobilityFromEUTRACommand message to UE.
The UE handover to UTRAN cell from E-UTRAN cell, and send HANDOVER TO UTRAN COMPLETE message and complete handover to Cell 1.
SS transmits a UE INFORMATION REQUEST message, and the IE "Logged Measurements Report Request" is present.
The UE shall transmit a UE INFORMATION REPONSE message, with IE "Logged Measurement Info-FDD" or "Logged Measurement Info-TDD".
Expected Sequence
Step |
Direction |
Message |
Comment |
|
---|---|---|---|---|
UE |
SS |
|||
1 |
ß |
LOGGING MEASUREMENT CONFIGURATION |
Include IE “Logged Measurements Configuration Info”, with “Logging Interval” set as 2.56s and “Logging Duration” set as 10min. |
|
2 |
ß |
RRC CONNECTION RELEASE |
||
3 |
à |
RRC CONNECTION RELEASE COMPLETE |
The UE sends this message before it completes state transition. |
|
4 |
Wait 10s to allow UE to activate logging. |
|||
5 |
à |
RRC CONNECTION REQUEST |
By outgoing call operation. |
|
6 |
ß |
RRC CONNECTION SETUP |
||
7 |
à |
RRC CONNECTION SETUP COMPLETE |
||
7a |
–> |
RRC: INITIAL DIRECT TRANSFER NAS: SERVICE REQUEST |
The UE transmits SERVICE REQUEST message. |
|
– |
– |
– |
For FDD, Steps 8 to 9 describe behaviour that depends on the UE capability; the "lower case letter" identifies a step sequence that takes place if a capability is supported. For TDD, go to Step 10. |
|
8 |
|
PHYSICAL CHANNEL RECONFIGURATION |
Compressed mode pattern sequence parameters are loaded to UE. |
|
9 |
|
PHYSICAL CHANNEL RECONFIGURATION COMPLETE |
||
10 |
|
MEASUREMENT CONTROL |
SS configures event 3a in the UE. If the UE requires compressed mode (refer ICS/IXIT), compressed mode is started. |
|
11 |
SS re-adjusts the downlink transmission power settings according to columns "T1" in tables 8.6.3.3. |
|||
12 |
|
MEASUREMENT REPORT |
After about 2s, the UE sends a MEASUREMENT REPORT to SS triggered by event 3a. |
|
13 |
ß |
HANDOVER FROM UTRAN COMMAND |
The SS transmits a HANDOVER FROM UTRAN COMMAND message to UE. |
|
14 |
|
RRCConnectionReconfigurationComplete |
The UE shall send a RRCConnectionReconfigurationComplete message to cell 2. |
|
15 |
ß |
RRCConnectionReconfiguration |
The SS transmits an RRCConnectionReconfiguration message to setup inter RAT measurement on Cell 2. |
|
16 |
|
RRCConnectionReconfigurationComplete |
The UE transmits an RRCConnectionReconfigurationComplete message to confirm the setup of inter RAT measurement on Cell 2. |
|
17 |
SS re-adjusts the downlink transmission power settings according to columns "T2" in tables 8.6.3.3. |
|||
18 |
|
MeasurementReport |
The UE transmits a MeasurementReport message to cell 2. |
|
19 |
ß |
MobilityFromEUTRACommand |
The SS transmits a MobilityFromEUTRACommand message on Cell 2. |
|
20 |
|
HANDOVER TO UTRAN COMPLETE |
The UE transmit a HANDOVER TO UTRAN COMPLETE message on cell 1. |
|
21 |
ß |
SECURITY MODE COMMAND |
The SS transmits a SECURITY MODE COMMAND message on Cell 1 in order to activate integrity protection. |
|
22 |
|
SECURITY MODE COMPLETE |
The UE transmits a SECURITY MODE COMPLETE message on Cell 1. |
|
23 |
ß |
UE INFORMATION REQUEST |
SS transmits a UE INFORMATION REQUEST message with IE "Logged Measurements Report Request" set to “true”. |
|
24 |
à |
UE INFORMATION RESPONSE |
The UE shall send a UE INFORMATION RESPONSE message, with IE "Logged Measurement Info-FDD" or "Logged Measurement Info-TDD" |
Specific Message Contents
Conditions for specific message contents
Condition |
Explanation |
Band > 64 |
If E-UTRA band > 64 is selected |
LOGGING MEASUREMENT CONFIGURATION (Step 1)
Information Element |
Value/remark |
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged ANR configuration Info |
|
– Absolute Time Info |
Set to value corresponding to the absolute time when the message is sent |
– Logging Duration |
10 min |
– Logging Interval |
|
– Trace reference |
|
– PLMN Identity |
Same as MIB |
– Trace ID |
‘0EF’H |
-Trace recording session |
‘1A’H |
– TCE Id |
‘5’H |
– CHOICE Area Configuration |
Not present |
PHYSICAL CHANNEL RECONFIGURATION (FDD) (Step 8)
Information Element |
Value/remark |
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an unused integer between 0 to 3 |
Integrity check info |
|
– Message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Integrity protection mode info |
Not Present |
Ciphering mode info |
Not Present |
Activation time |
Not Present |
Delay restriction flag |
Not Present |
New U-RNTI |
Not Present |
New C-RNTI |
Not Present |
New H-RNTI |
Not Present |
New Primary E-RNTI |
Not Present |
New Secondary E-RNTI |
Not Present |
RRC State indicator |
CELL_DCH |
UE Mobility State Indicator |
Not Present |
UTRAN DRX cycle length coefficient |
Not Present |
CN information info |
Not Present |
URA identity |
Not Present |
RNC support for change of UE capability |
Not Present |
Reconfiguration in response to requested change of UE capability |
Not Present |
Downlink counter synchronization info |
Not Present |
Frequency info |
Not Present |
DTX-DRX timing information |
Not Present |
DTX-DRX Information |
Not Present |
HS-SCCH less Information |
Not Present |
MIMO parameters |
Not Present |
HARQ Info |
Not Present |
Maximum allowed UL TX power |
Not Present |
CHOICE channel requirement |
Not Present |
E-DCH Info |
Not Present |
Downlink HS-PDSCH Information |
Not Present |
Downlink information common for all radio links |
|
– Downlink DPCH info common for all RL |
Not Present |
– DPCH compressed mode info |
|
– TGPSI |
1 |
– TGPS Status Flag |
Deactivate |
– TGCFN |
Not Present |
– Transmission gap pattern sequence configuration parameters |
|
– TGMP |
E-UTRA measurement |
– TGPRC |
Infinity |
– TGSN |
8 |
– TGL1 |
10 |
– TGL2 |
Not Present |
– TGD |
undefined |
– TGPL1 |
12 |
– TGPL2 |
Not Present |
– RPP |
Mode 0 |
– ITP |
Mode 0 |
– CHOICE UL/DL Mode |
UL and DL, UL only or DL only (depending on the UE capability) |
– Downlink compressed mode method |
HLS(or not sent, depending on the UE capability) |
– Uplink compressed mode method |
HLS(or not sent, depending on the UE capability) |
– Downlink frame type |
B |
– DeltaSIR1 |
20 (2.0) |
– DeltaSIRAfter1 |
10 (1.0) |
– DeltaSIR2 |
Not Present |
– DeltaSIRAfter2 |
Not Present |
– N identify abort |
Not Present |
– T Reconfirm abort |
Not Present |
– TX Diversity mode |
Not Present |
– SSDT information |
Not Present |
– Default DPCH Offset Value |
Not Present |
Downlink information for each radio link |
Not Present |
MBMS PL Service Restriction Information |
Not Present |
MEASUREMENT CONTROL (FDD) (Step 10)
Information Element |
Value/remark |
Conditions |
Message Type |
||
RRC transaction identifier |
Arbitrarily selects an unused integer between 0 to 3 |
|
Integrity check info |
||
– Message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
|
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
|
Measurement Identity |
3 |
|
Measurement Command |
Setup |
|
Measurement Reporting Mode |
||
– Measurement Report Transfer Mode |
Acknowledged mode RLC |
|
– Periodical Reporting/Event Trigger Reporting Mode |
Event trigger |
|
Additional measurement list |
Not present |
|
CHOICE Measurement type |
Inter-RAT measurement |
|
– CHOICE Inter-RAT measurement objects |
E-UTRA frequency list |
|
– CHOICE E-UTRA frequency removal |
Remove no frequencies |
|
– New frequencies |
||
– E-UTRA carrier frequency |
Downlink EARFCN of E-UTRA Cell |
|
– E-UTRA carrier frequency |
65535 |
Band > 64 |
– EARFCN extension |
Downlink EARFCN of E-UTRA Cell |
Band > 64 |
– Measurement bandwidth |
Same downlink system bandwidth as used for E-UTRA Cell |
|
– Blacklisted cells list |
Not present |
|
– Inter-RAT measurement quantity |
||
– Measurement quantity for UTRAN quality estimate |
||
– Filter coefficient |
0 |
|
– CHOICE mode |
FDD |
|
– Measurement quantity |
CPICH Ec/N0 |
|
– CHOICE system |
E-UTRA |
|
– Measurement quantity |
RSRP |
|
– Filter coefficient |
0 |
|
– Inter-RAT reporting quantity |
||
– UTRAN estimated quality |
FALSE |
|
– CHOICE system |
E-UTRA |
|
– Reporting quantity |
both |
|
– Reporting cell status |
Not present |
|
– CHOICE report criteria |
Inter-RAT measurement reporting criteria |
|
– Parameters required for each event |
1 entry |
|
– Inter-RAT event identity |
Set according to specific test. |
|
– Threshold own system |
-66 dB |
|
– W |
0 |
|
– Threshold other system |
-55 (-80 dBm) |
|
– Hysteresis |
0 |
|
– Time to trigger |
10 ms |
|
– Reporting cell status |
||
– CHOICE reported cell |
Report cells within active set or within virtual active set or of the other RAT |
|
– Maximum number of reported cells |
2 |
|
– Idle Interval Information |
Not present |
|
DPCH Compressed mode status info |
||
– TGPS reconfiguration CFN |
(Current CFN + (250 – TTI/10msec)) mod 256 |
|
– Transmission gap pattern sequence |
1 entry |
|
– TGPSI |
1 |
|
– TGPS Status Flag |
activate |
|
– TGCFN |
(Current CFN + (252 – TTI/10msec)) mod 256 |
MEASUREMENT CONTROL (TDD) (Step 10)
Information Element |
Value/remark |
Conditions |
Message Type |
||
RRC transaction identifier |
Arbitrarily selects an unused integer between 0 to 3 |
|
Integrity check info |
||
– Message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
|
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
|
Measurement Identity |
3 |
|
Measurement Command |
Setup |
|
Measurement Reporting Mode |
||
– Measurement Report Transfer Mode |
Acknowledged mode RLC |
|
– Periodical Reporting/Event Trigger Reporting Mode |
Event trigger |
|
Additional measurement list |
Not present |
|
CHOICE Measurement type |
Inter-RAT measurement |
|
– CHOICE Inter-RAT measurement objects |
E-UTRA frequency list |
|
– CHOICE E-UTRA frequency removal |
Remove no frequencies |
|
– New frequencies |
||
– E-UTRA carrier frequency |
Downlink EARFCN of E-UTRA Cell |
|
– E-UTRA carrier frequency |
65535 |
Band > 64 |
– EARFCN extension |
Downlink EARFCN of E-UTRA Cell |
Band > 64 |
– Measurement bandwidth |
Same downlink system bandwidth as used for E-UTRA Cell |
|
– Blacklisted cells list |
Not present |
|
– Inter-RAT measurement quantity |
||
– Measurement quantity for UTRAN quality estimate |
||
– Filter coefficient |
0 |
|
– CHOICE mode |
TDD |
|
– Measurement quantity |
Primary CCPCH RSCP |
|
– CHOICE system |
E-UTRA |
|
– Measurement quantity |
RSRP |
|
– Filter coefficient |
0 |
|
– Inter-RAT reporting quantity |
||
– UTRAN estimated quality |
FALSE |
|
– CHOICE system |
E-UTRA |
|
– Reporting quantity |
both |
|
– Reporting cell status |
Not present |
|
– CHOICE report criteria |
Inter-RAT measurement reporting criteria |
|
– Parameters required for each event |
1 entry |
|
– Inter-RAT event identity |
Set according to specific test. |
|
– Threshold own system |
-66 dB |
|
– W |
0 |
|
– Threshold other system |
-55 (-80 dBm) |
|
– Hysteresis |
0 |
|
– Time to trigger |
10 ms |
|
– Reporting cell status |
||
– CHOICE reported cell |
Report cells within active set or within virtual active set or of the other RAT |
|
– Maximum number of reported cells |
2 |
|
– Idle Interval Information |
Not present |
|
DPCH Compressed mode status info |
Not present |
MEASUREMENT REPORT (Step 12)
Information Element |
Value/remark |
Conditions |
Integrity check info |
||
– Message authentication code |
This IE is checked to see if it is present. The value is compared against the XMAC-I value computed by SS. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
|
– RRC Message sequence number |
This IE is checked to see if it is present. The value is used by SS to compute the XMAC-I value. |
|
Activation time |
(256+CFN-(CFN MOD 8 + 8)) MOD 256 |
|
Measurement identity |
3 |
|
Measured Results |
Not present |
|
Measured results on RACH |
Not present |
|
Additional measured results |
Not present |
|
Event results |
Not present |
|
Inter-RAT cell info indication |
Not present |
|
E-UTRA Measured Results |
||
– E-UTRA measured results list |
1 entry |
|
– E-UTRA Carrier Frequency |
||
– Measured E-UTRA cells |
1 entry |
|
– Physical Cell Identity |
PhysicalCellIdentity of Cell 2 |
|
– RSRP |
Set according to specific test. |
|
– RSRQ |
Set according to specific test. |
|
E-UTRA Event Results |
||
– Inter-RAT event identity |
Set according to specific test. |
|
– E-UTRA events results list |
1 entry |
|
– E-UTRA Carrier Frequency |
Downlink EARFCN of Cell 2 |
|
– E-UTRA Carrier Frequency |
65535 |
Band > 64 |
– Reported cells |
1 entry |
|
– Physical Cell Identity |
PhysicalCellIdentity of Cell 2 |
|
– E-UTRA events results extension list |
1 entry |
Band > 64 |
– EARFCN extension |
Downlink EARFCN of Cell 2 |
HANDOVER TO UTRAN COMPLETE (Step 20)
Information Element |
Value/remark |
Message Type |
|
UE Information elements |
|
START list |
Not checked |
– CN domain identity |
Not checked |
– START |
Not checked |
RB Information elements |
|
– COUNT-C activation time |
Not checked |
Other Information elements |
|
– Logged Meas Available |
TRUE |
UE INFORMATION RESPONSE (FDD) (Step 24)
Information Element |
Value/remark |
Conditions |
---|---|---|
Message Type |
||
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
|
Integrity check info |
||
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
|
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
|
Logged Meas Report |
||
– Absolute Time Info |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
|
– Trace reference |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
|
– PLMN Identity |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
|
– Trace ID |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
|
– Trace recording session |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
|
– TCE Id |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
|
– CHOICE mode |
FDD |
|
– List of measurements FDD |
At least 1 entry where at least one entry complies to entry with index ‘x’ below. |
|
– Logged Measurement Info-FDD[x] |
||
– Relative Time Stamp[x] |
Not checked |
|
– Logged Measurements Serving Cell[x] |
||
– Cell ID[x] |
Cell 1 |
|
– Primary CCPCH RSCP[x] |
(0..91) |
|
– CPICH Ec/N0 |
(0..49) |
|
– Logged Measurements Inter-RAT Neighbour cells list |
||
– Logged Measurements E-UTRA frequency list |
1 entry |
|
– E-UTRA Carrier Frequency |
Same as cell 2 |
|
– E-UTRA Carrier Frequency |
65535 |
Band > 64 |
– Logged Measurements E-UTRA Frequency Neighbours List |
1 entry |
|
– Physical Cell Identity |
Same as cell 2 |
|
– RSRP |
(0..97) |
|
– RSRQ |
(0..34) |
|
– Logged Measurements E-UTRA frequency extension list |
1 entry |
|
– EARFCN extension |
Same as cell 2 |
Band > 64 |
– Logged Meas Available |
Not checked |
UE INFORMATION RESPONSE (TDD) (Step 24)
Information Element |
Value/remark |
Conditions |
---|---|---|
Message Type |
||
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
|
Integrity check info |
||
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
|
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
|
Logged Meas Report |
||
– Absolute Time Info |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
|
– Trace reference |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
|
– PLMN Identity |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
|
– Trace ID |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
|
– Trace recording session |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
|
– TCE Id |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
|
– CHOICE mode |
TDD |
|
– List of measurements TDD |
At least 1 entry where at least one entry complies to entry with index ‘x’ below. |
|
– Logged Measurement Info-TDD[x] |
||
– Relative Time Stamp[x] |
Not checked |
|
– Logged Measurements Serving Cell[x] |
||
– Cell ID |
Cell 1 |
|
– Primary CCPCH RSCP |
(0..91) |
|
– Logged Measurements Inter-RAT Neighbour cells list |
||
– Logged Measurements E-UTRA frequency list |
1 entry |
|
– E-UTRA Carrier Frequency |
Same as cell 2 |
|
– E-UTRA Carrier Frequency |
65535 |
Band > 64 |
– Logged Measurements E-UTRA Frequency Neighbours List |
1 entry |
|
– Physical Cell Identity |
Same as cell 2 |
|
– RSRP |
(0..97) |
|
– RSRQ |
(0..34) |
|
– Logged Measurements E-UTRA frequency extension list |
1 entry |
|
– EARFCN extension |
Same as cell 2 |
Band > 64 |
– Logged Meas Available |
Not checked |
8.6.3.3.5 Test requirement
At step 20, the UE shall transmit a HANDOVER TO UTRAN COMPLETE message, with the IE "Logged Meas Available" on Cell 1 (TP1).
At step 24, the UE shall transmit a UE INFORMATION RESPONSE message includes IE “Logged Meas Report" with logged Measurements of Cell 1 and Cell 2 (TP2).
8.6.3.4 Logged MDT / Maintaining logged measurement configuration / UTRAN to GERAN Inter-RAT mobility
8.6.3.4.1 Definition
8.6.3.4.2 Conformance requirement
[TS 25.304, clause 5.7 (TP1)]
The UE may be configured to perform logging of measurement results in idle mode, CELL_PCH and URA_PCH state with LOGGING MEASUREMENT CONFIGURATION message specified in TS 25.331 [4]. This configuration is valid while the logging duration timer is running.
If the configuration of logged measurements is valid, the UE shall perform logging of measurement results if all of the following conditions are met:
– the UE is in camped normally state in idle mode, CELL_PCH or URA_PCH state;
– RPLMN of the UE is the same as the RPLMN at the point of time of LOGGING MEASUREMENT CONFIGURATION message reception.
– the UE is camped on a cell belonging to Area Configuration (see TS 25.331 [4]), if configured;
– the UE is camped on the RAT where the logged measurement configuration was received.
Otherwise, the logging of measurement results shall be suspended.
NOTE: Even if logging of measurement results is suspended, the logging duration timer and time stamp will continue, and the logged measurement configuration and corresponding log are kept.
[TS 25.331, clause 8.5.65.2 (TP1)]
While T326 is running, the UE shall:
1> perform this logging in accordance with the following:
2> perform the logging while camping normally on an UTRA cell and the RPLMN of the UE is the same as the PLMN Identity stored in LOGGED_MEAS_REPORT_VARIABLE and, if the IE "Area Configuration" is present in variable LOGGED_MEAS_CONFIG, that is part of the concerned area;
2> perform the logging at regular intervals, as defined by the IE "Logging Interval" in variable LOGGED_MEAS_CONFIG;
2> when adding a logged measurement entry in variable LOGGED_MEAS_REPORT_VARIABLE, include the fields in accordance with the following:
3> set the IE "Relative Time Stamp" to indicate time relative to the moment at which the logged measurement configuration was received;
3> if GNSS location information became available during the last logging interval:
4> if the UE has been able to calculate a 3-dimensional position:
5> set IE "Ellipsoid point with altitude" to include the location coordinates;
4> else:
5> set IE "Ellipsoid point" to include the location coordinates:
3> set the IE "Cell ID" to indicate cell identity of the cell the UE is camping on obtained from system information;
3> set the IE "CPICH Ec/N0" and "CPICH RSCP" to include measured quantities of the cell that the UE is camping on for UTRA FDD;
3> set the "P-CCPCH RSCP" to include measured quantities for the cell that the UE is camping on for UTRA 1.28 Mcps TDD;
3> set the IE "Logged Measurements Intra Frequency Neighbouring Cells list", "Logged Measurements Inter Frequency list", "Logged Measurements E-UTRA frequency list", in order of decreasing ranking quantity as used for cell re-selection in each frequency for at most the following number of neighbouring cells; 6 intra-frequency and 3 inter-frequency neighbours per frequency as well as 3 inter-RAT neighbours, per frequency per RAT;
3> set the IE "Logged Measurements GSM Neighbouring Cells list" in order of decreasing RXLEV.
NOTE: The UE includes, only once, the latest available results of the measurement performed for cell reselection, which are performed in accordance with the regular performance requirements as specified in [19].
2> when the memory reserved for the logging of measurements becomes full, stop timer T326 and performs the same actions as performed upon expiry of T326, as specified in 8.5.63.4.
[TS 25.331, clause 8.5.64.3 (TP1)]
UE Shall:
1> if IE "Logged Measurements Report Request" is present:
2> if Registered PLMN is the same as the IE "PLMN Identity" stored in variable LOGGED_MEAS_REPORT_VARIABLE:
3> if an IE "Logged Measurement Info-FDD" or "Logged Measurement Info-TDD" in variable LOGGED_MEAS_REPORT_VARIABLE is present:
- set IE "Logged Meas Report" in the UE INFORMATION RESPONSE as follows:
5> include the IE "Absolute Time Info" and set it to the value of the IE "Absolute Time Info" in the variable LOGGED_MEAS_REPORT_VARIABLE;
5> include the IE "Trace reference" and set it to the value of IE "Trace reference" in the variable LOGGED_MEAS_REPORT_VARIABLE;
5> include the IE "Trace recording session" and set it to the value of IE "Trace recording session" in the variable LOGGED_MEAS_REPORT_VARIABLE;
5> include the IE "TCE Id" and set it to the value of IE "TCE Id" in the variable LOGGED_MEAS_REPORT_VARIABLE;
5> include the IEs "Logged Measurement Info-FDD" or "Logged Measurement Info-TDD" and set it to include, in the same order as logged, one or more entries from LOGGED_MEAS_REPORT_VARIABLE;
5> clear the logged measurement results included in the list of IEs "Logged Measurement Info-FDD" or "Logged Measurement Info-TDD" from LOGGED_MEAS_REPORT_VARIABLE;
5> if the variable LOGGED_MEAS_REPORT_VARIABLE is not empty:
6> include IE "Logged Meas Available";
2> transmit a UE INFORMATION RESPONSE message on the uplink DCCH using AM RLC.
1> if IE "Logged ANR Report Request" is present:
2> if Registered PLMN is the same as the IE "PLMN Identity" stored in variable LOG_ANR_REPORT_VARIABLE:
3> if IE "Logged ANR Report Info" in variable LOG_ANR_REPORT_VARIABLE is present:
4> set IEs "Logged ANR Report Info" in the UE INFORMATION RESPONSE as follows:
5> include the IEs "Logged ANR Report Info List" and set it to include entries from LOG_ANR_REPORT_VARIABLE;
5> clear the logged measurement results included in the list of IEs "Logged ANR Report Info List" from the LOG_ANR_REPORT_VARIABLE;
5> clear the variable LOG_ANR_CONFIG and stop timer T327.
2> transmit a UE INFORMATION RESPONSE message on the uplink DCCH using AM RLC.
[TS 37.320, clause 5.1.1.3.1 (TP2)]
A UE configured to perform Logged MDT measurements indicates the availability of Logged MDT measurements, by means of an indicator, in RRCConnectionSetupComplete message during connection establishment. Furthermore, the indicator (possibly updated) shall be provided within E-UTRAN handover and re-establishment, and UTRAN procedures involving the change of SRNC (SRNC relocation), CELL UPDATE, URA UPDATE messages as well as MEASUREMENT REPORT message in case of state transition to CELL_FACH without CELL UPDATE. The UE includes the indication in one of these messages at every transition to RRC Connected mode even though the logging period has not ended, upon connection to RAT which configured the UE to perform Logged MDT measurements and RPLMN which is equal to a PLMN in the MDT PLMN list.
The indicator shall be also provided in UEInformationResponse message during MDT report retrieval in case the UE has not transferred the total log in one RRC message in order to indicate the remaining data availability.
The UE will not indicate the availability of MDT measurements in another RAT or in a PLMN that is not in the MDT PLMN list.
The network may decide to retrieve the logged measurements based on this indication. In case Logged MDT measurements are retrieved before the completion of the pre-defined logging duration, the reported measurement results are deleted, but MDT measurement logging will continue according to ongoing logged measurement configuration.
In case the network does not retrieve Logged MDT measurements, UE should store non-retrieved measurements for 48 hours from the moment the duration timer for logging expired. There is no requirement to store non-retrieved data beyond 48 hours. In addition, all logged measurement configuration and the log shall be removed by the UE at switch off or detach.
Reference
TS 25.304 clause 5.7, TS 25.331 clauses 8.5.65.2, 8.5.64.3 and TS37.320 clause 5.1.1.3.1.
8.6.3.4.3 Test Purpose
1. Verify indication of availability of Logged MDT measurements in HANDOVER TO UTRAN COMMAND message.
2. Verify that logged measurement configurations and logs are maintained despite periods of interruptions due to UE transitions to other RAT.
8.6.3.4.4 Method of test
Initial Condition
System Simulator: 2 cells – cell 1 and cell 9 are active. Cell 1 is UTRA FDD or TDD cells. Cell 9 is GSM cell. The PLMN of Cell 1 and Cell 9 are the same.
UE: CELL_DCH (state 6-9) in cell 1 as specified in clause 7.4 of TS 34.108.
Test Procedure
Table 8.6.3.4-1
Parameter |
Unit |
Cell 1 (UTRA) |
||
T0 |
T1 |
T2 |
||
UTRA RF Channel Number |
Mid Range Test Frequency |
|||
CPICH Ec(FDD) |
dBm/3.84MHz |
-60 |
-80 |
-60 |
PCCPCH_RSCP (TDD) |
dBm |
-60 |
-80 |
-60 |
Table 8.6.3.4-2
Parameter |
Unit |
Cell 9 (GSM) |
||
T0 |
T1 |
T2 |
||
Test Channel |
1 |
|||
RF Signal Level |
dBm |
-90 |
-48 |
-90 |
RXLEV_ACCESS_MIN |
dBm |
-100 |
||
FDD_Qmin |
dB |
-20 |
||
FDD_Qoffset |
dBm |
0 |
Table 8.6.3.4-1 and table 8.6.3.4-2 illustrate the downlink power to be applied for the 2 cells at various time instants of the test execution. Columns marked "T0" denote the initial conditions, while column marked “T1” and “T2” is to be applied subsequently. The exact instants on which these values shall be applied are described in the texts in this clause.
The UE is in CELL_DCH state of cell 1.
SS transmits a LOGGING MEASUREMENT CONFIGURATION message to the UE to configure logged measurements.
SS disconnects the CS call.
SS transmits an RRC CONNECTION RELEASE message to the UE to disconnect the connection.
The UE transmits an RRC CONNECTION RELEASE COMPLETE message using unacknowledged mode.
Wait 10s to allow UE to activate logging.
The SS configures its downlink transmission power settings according to columns "T1" in tables’ 8.6.3.4-1 and 8.6.3.4-2. The UE performs cell re-selection to Cell 9 and performs location update.
UE triggers an MO call and enters U10 call active state.
The SS configures its downlink transmission power settings according to columns "T2" in tables’ 8.6.3.4-1 and 8.6.3.4-2.
The SS sends a MEASUREMENT INFORMATION to trigger the MS to perform measurements on the UTRAN cell.
The UE sends a MEASUREMENT REPORT to SS.
The SS sends INTERSYSTEM TO UTRAN HANDOVER COMMAND indicating the dedicated channel of the target cell to the MS through the GSM serving cell.
The UE handover to UTRAN cell from GERAN cell, and send HANDOVER TO UTRAN COMMAND message.
SS transmits a UE INFORMATION REQUEST message, and the IE "Logged Measurements Report Request" is present.
The UE shall transmit a UE INFORMATION REPONSE message, with IE "Logged Measurement Info-FDD" or "Logged Measurement Info-TDD".
Expected Sequence
Step |
Direction |
Message |
Comment |
|
---|---|---|---|---|
UE |
SS |
|||
1 |
ß |
LOGGING MEASUREMENT CONFIGURATION |
Include IE “Logged Measurements Configuration Info”, with “Logging Interval” set as 2.56s and “Logging Duration” set as 10min. |
|
2 |
<- |
DISCONNECT |
SS disconnects the CS call |
|
3 |
-> |
RELEASE |
||
4 |
<- |
RELEASE COMPLETE |
||
5 |
ß |
RRC CONNECTION RELEASE |
||
6 |
à |
RRC CONNECTION RELEASE COMPLETE |
The UE sends this message before it completes state transition. |
|
7 |
Wait 10s to allow UE to activate logging. |
|||
8 |
The SS configures its downlink transmission power settings according to columns "T1" in tables’ 8.6.3.4-1 and 8.6.3.4-2. The UE performs cell re-selection to Cell 9. |
|||
9 |
|
CHANNEL REQUEST |
The SS receives this burst on the RACH of cell 9(GSM cell). (triggered by UE location update procedure or RAU procedure) |
|
10 |
|
IMMEDIATE ASSIGNMENT |
Sent on AGCH. |
|
11 |
SS |
The SS completes the Location Update procedure or RAU procedure requested by the UE. |
||
12-28 |
– |
– |
The generic test procedure in TS 51.010-1 sub clause 10.2.3 are performed NOTE: Mobile originating CS call is established. |
|
29 |
– |
– |
The SS configures its downlink transmission power settings according to columns "T2" in tables’ 8.6.3.4-1 and 8.6.3.4-2. |
|
30 |
|
MEASUREMENT INFORMATION |
||
31 |
|
MEASUREMENT REPORT |
Including Measurement Results on the UTRAN cell in Step 4 |
|
32 |
|
INTERSYSTEM TO UTRAN HANDOVER COMMAND |
Send on cell 9 (GSM cell) |
|
33 |
|
HANDOVER TO UTRAN COMPLETE |
The UE transmit a HANDOVER TO UTRAN COMPLETE message on cell 1. |
|
34 |
ß |
SECURITY MODE COMMAND |
The SS transmits a SECURITY MODE COMMAND message on Cell 1 in order to activate integrity protection. |
|
35 |
|
SECURITY MODE COMPLETE |
The UE transmits a SECURITY MODE COMPLETE message on Cell 1. |
|
36 |
ß |
UE INFORMATION REQUEST |
SS transmits a UE INFORMATION REQUEST message with IE "Logged Measurements Report Request" set to “true”. |
|
37 |
à |
UE INFORMATION RESPONSE |
The UE shall send a UE INFORMATION RESPONSE message, with IE "Logged Measurement Info-FDD" or "Logged Measurement Info-TDD" |
Specific Message Contents
LOGGING MEASUREMENT CONFIGURATION (Step 1)
Information Element |
Value/remark |
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged ANR configuration Info |
|
– Absolute Time Info |
Set to value corresponding to the absolute time when the message is sent |
– Logging Duration |
10 min |
– Logging Interval |
|
– Trace reference |
|
– PLMN Identity |
Same as MIB |
– Trace ID |
‘0EF’H |
-Trace recording session |
‘1A’H |
– TCE Id |
‘5’H |
– CHOICE Area Configuration |
Not present |
HANDOVER TO UTRAN COMPLETE (Step 33)
Information Element |
Value/remark |
Message Type |
|
UE Information elements |
|
START list |
Not checked |
– CN domain identity |
Not checked |
– START |
Not checked |
RB Information elements |
|
– COUNT-C activation time |
Not checked |
Other Information elements |
|
– Logged Meas Available |
TRUE |
FFS
UE INFORMATION RESPONSE (FDD) (Step 37)
Information Element |
Value/remark |
---|---|
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Meas Report |
|
– Absolute Time Info |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace reference |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– PLMN Identity |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace ID |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace recording session |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– TCE Id |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– CHOICE mode |
FDD |
– List of measurements FDD |
At least 1 entry where at least one entry complies to entry with index ‘x’ below. |
– Logged Measurement Info-FDD[x] |
|
– Relative Time Stamp[x] |
Not checked |
– Logged Measurements Serving Cell[x] |
|
– Cell ID[x] |
Cell 1 |
– Primary CCPCH RSCP[x] |
(0..91) |
– CPICH Ec/N0 |
(0..49) |
– Logged Measurements Inter-RAT Neighbour cells list |
|
– Logged Measurements GSM Neighbouring Cells list |
|
– BSIC |
Same as cell 9 |
– Band indicator |
Same as cell 9 |
– BCCH ARFCN |
Same as cell 9 |
– GSM carrier RSSI |
(0…63) |
– Logged Meas Available |
Not checked |
UE INFORMATION RESPONSE (TDD) (Step 37)
Information Element |
Value/remark |
---|---|
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Meas Report |
|
– Absolute Time Info |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace reference |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– PLMN Identity |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace ID |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace recording session |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– TCE Id |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– CHOICE mode |
TDD |
– List of measurements TDD |
At least 1 entry where at least one entry complies to entry with index ‘x’ below. |
– Logged Measurement Info-TDD[x] |
|
– Relative Time Stamp[x] |
Not checked |
– Logged Measurements Serving Cell[x] |
|
– Cell ID |
Cell 1 |
– Primary CCPCH RSCP |
(0..91) |
– Logged Measurements Inter-RAT Neighbour cells list |
|
– Logged Measurements GSM Neighbouring Cells list |
1 entry |
– BSIC |
Same as cell 9 |
– Band indicator |
Same as cell 9 |
– BCCH ARFCN |
Same as cell 9 |
– GSM carrier RSSI |
(0…63) |
– Logged Meas Available |
Not checked |
8.6.3.4.5 Test requirement
At step 33, the UE shall transmit a HANDOVER TO UTRAN COMPLETE message, with the IE "Logged Meas Available" on Cell 1 (TP1).
At step 37, the UE shall transmit a UE INFORMATION RESPONSE message includes IE “Logged Meas Report" with logged Measurements of Cell 1 and Cell 9 (TP2).