8.6.2 Logged MDT
34.123-13GPPPart 1: Protocol conformance specificationRelease 15TSUser Equipment (UE) conformance specification
8.6.2.1 Logged MDT / Intra-frequency measurement, logging and reporting / Idle mode
8.6.2.1.1 Definition
8.6.2.1.2 Conformance requirement
[TS 25.304, clause 5.7 (TP1, TP2)]
The UE may be configured to perform logging of measurement results in idle mode, CELL_PCH and URA_PCH state with LOGGING MEASUREMENT CONFIGURATION message specified in TS 25.331 [4]. This configuration is valid while the logging duration timer is running.
If the configuration of logged measurements is valid, the UE shall perform logging of measurement results if all of the following conditions are met:
– the UE is in camped normally state in idle mode, CELL_PCH or URA_PCH state;
– RPLMN of the UE is the same as the RPLMN at the point of time of LOGGING MEASUREMENT CONFIGURATION message reception
– the UE is camped on a cell belonging to Area Configuration (see TS 25.331 [4]), if configured;
– the UE is camped on the RAT where the logged measurement configuration was received.
Otherwise, the logging of measurement results shall be suspended.
NOTE: Even if logging of measurement results is suspended, the logging duration timer and time stamp will continue, and the logged measurement configuration and corresponding log are kept.
[TS 25.331, clause 8.1.3.6 (TP3)]
The UE shall compare the value of the IE "Initial UE identity" in the received RRC CONNECTION SETUP message with the value of the variable INITIAL_UE_IDENTITY.
If the values are different, the UE shall:
1> ignore the rest of the message.
If the values are identical, the UE shall:
…
1> submit an RRC CONNECTION SETUP COMPLETE message to the lower layers on the uplink DCCH after successful state transition per subclause 8.6.3.3, with the contents set as specified below:
…
2> if an IE "Logged ANR Report Info" in variable LOG_ ANR_REPORT_VARIABLE is present and the registered PLMN is the same as one of the PLMNs in the IE "PLMN Identity" or IE "Equivalent PLMN Identity List" stored in variable LOG_ANR_REPORT_VARIABLE:
3> include IE "ANR Logging Results Available".
…
When the RRC CONNECTION SETUP COMPLETE message has been submitted to lower layers for transmission the UE shall:
…
[TS 25.331, clause 8.5.63.3 (TP1)]
Upon receiving the LOGGING MEASUREMENT CONFIGURATION message the UE shall:
1> if IE "Logged Measurements Configuration Info" is present:
2> if stored, discard the existing logged measurement configuration as well as the logged measurement information as specified in 8.5.66;
2> store the received IEs "Logging Duration", "Logging Interval", "Area Configuration" if included in IE "Logged Measurements Configuration Info" in variable LOGGED_MEAS_CONFIG and IEs "Absolute Time Info", "Trace reference", "Trace recording session" and "TCE Id" in variable LOGGED_MEAS_REPORT_VARIABLE;
2> store the current Registered PLMN in the IE "PLMN Identity" in variable LOGGED_MEAS_REPORT_VARIABLE;
2> start timer T326 with the timer value set to the IE "Logging Duration".
NOTE: The UE should not stop timer T326 unless explicitly stated when it moves to another RAT.
1> if IE "Logged ANR configuration Info" is present:
2> if variable LOG_ANR_CONFIG was already stored, discard the existing logged measurement configuration for ANR purpose as well as the associated logged measurement information as specified in 8.5.68;
2> store the received IEs in the IE "Logged ANR configuration Info" in variable LOG_ANR_CONFIG;
2> store the current Registered PLMN in the IE "PLMN Identity" in variable LOG_ANR_REPORT_VARIABLE;
2> store the list of Equivalent PLMNs in the IE "Equivalent PLMN Identity List" in variable LOG_ANR_REPORT_VARIABLE;
2> start timer T327 with the timer value set to the IE "Logging Duration" included in IE "Logged ANR configuration Info".
[TS 25.331, clause 8.5.64.3 (TP2)]
UE Shall:
1> if IE "Logged Measurements Report Request" is present:
2> if Registered PLMN is the same as the IE "PLMN Identity" stored in variable LOGGED_MEAS_REPORT_VARIABLE:
3> if an IE "Logged Measurement Info-FDD" or "Logged Measurement Info-TDD" in variable LOGGED_MEAS_REPORT_VARIABLE is present:
- set IE "Logged Meas Report" in the UE INFORMATION RESPONSE as follows:
5> include the IE "Absolute Time Info" and set it to the value of the IE "Absolute Time Info" in the variable LOGGED_MEAS_REPORT_VARIABLE;
5> include the IE "Trace reference" and set it to the value of IE "Trace reference" in the variable LOGGED_MEAS_REPORT_VARIABLE;
5> include the IE "Trace recording session" and set it to the value of IE "Trace recording session" in the variable LOGGED_MEAS_REPORT_VARIABLE;
5> include the IE "TCE Id" and set it to the value of IE "TCE Id" in the variable LOGGED_MEAS_REPORT_VARIABLE;
5> include the IEs "Logged Measurement Info-FDD" or "Logged Measurement Info-TDD" and set it to include, in the same order as logged, one or more entries from LOGGED_MEAS_REPORT_VARIABLE;
5> clear the logged measurement results included in the list of IEs "Logged Measurement Info-FDD" or "Logged Measurement Info-TDD" from LOGGED_MEAS_REPORT_VARIABLE;
5> if the variable LOGGED_MEAS_REPORT_VARIABLE is not empty:
6> include IE "Logged Meas Available";
2> transmit a UE INFORMATION RESPONSE message on the uplink DCCH using AM RLC.
…
[TS 25.331, clause 8.5.65 (TP1, TP2)]
When in idle mode, CELL_PCH or URA_PCH state and Logged Measurements has been configured, the UE shall:
1> Store the available measurements according to the logged measurements configuration in LOGGED_MEAS_CONFIG variable as specified in subclause 8.5.65.2.
[TS 25.331, clause 8.5.65.2 (TP1, TP2, TP4)]
While T326 is running, the UE shall:
1> perform this logging in accordance with the following:
2> perform the logging while camping normally on an UTRA cell and the RPLMN of the UE is the same as the PLMN Identity stored in LOGGED_MEAS_REPORT_VARIABLE and, if the IE "Area Configuration" is present in variable LOGGED_MEAS_CONFIG, that is part of the concerned area;
2> perform the logging at regular intervals, as defined by the IE "Logging Interval" in variable LOGGED_MEAS_CONFIG;
2> when adding a logged measurement entry in variable LOGGED_MEAS_REPORT_VARIABLE, include the fields in accordance with the following:
3> set the IE "Relative Time Stamp" to indicate time relative to the moment at which the logged measurement configuration was received;
3> if GNSS location information became available during the last logging interval:
4> if the UE has been able to calculate a 3-dimensional position:
5> set IE "Ellipsoid point with altitude" to include the location coordinates;
4>else:
5> set IE "Ellipsoid point" to include the location coordinates:
3> set the IE "Cell ID" to indicate cell identity of the cell the UE is camping on obtained from system information;
3> set the IE "CPICH Ec/N0" and "CPICH RSCP" to include measured quantities of the cell that the UE is camping on for UTRA FDD;
3> set the "P-CCPCH RSCP" to include measured quantities for the cell that the UE is camping on for UTRA 1.28 Mcps TDD;
3> set the IE "Logged Measurements Intra Frequency Neighbouring Cells list", "Logged Measurements Inter Frequency list", "Logged Measurements E-UTRA frequency list", in order of decreasing ranking quantity as used for cell re-selection in each frequency for at most the following number of neighbouring cells; 6 intra-frequency and 3 inter-frequency neighbours per frequency as well as 3 inter-RAT neighbours, per frequency per RAT;
3> set the IE "Logged Measurements GSM Neighbouring Cells list" in order of decreasing RXLEV.
NOTE: The UE includes, only once, the latest available results of the measurement performed for cell reselection, which are performed in accordance with the regular performance requirements as specified in [19].
2> when the memory reserved for the logging of measurements becomes full, stop timer T326 and performs the same actions as performed upon expiry of T326, as specified in 8.5.63.4.
Reference
3GPP TS 25.304 clause 5.7 and TS 25.331 clauses 8.1.3.6, 8.5.63.3, 8.5.64.3, 8.5.65, 8.5.65.2.
8.6.2.1.3 Test Purpose
1. Verify logging of configured Logged MDT measurements in Idle mode.
2. Verify logging and reporting of Logged MDT Intra-frequency measurements.
3. Verify indication of availability of Logged MDT measurements at RRC connection establishment.
4. Verify presence of correct time stamp in Logged MDT measurement reports.
8.6.2.1.4 Method of test
Initial Condition
System Simulator: 2 cells, Cell 1 and Cell 2 are active. Cell 1 and Cell 2 belongs to same PLMN, but have different Location Area Codes.
UE: PS-DCCH+DTCH_DCH (state 6-10) in Cell 1 as specified in clause 7.4 of TS 34.108.
Test Procedure
Table 8.6.2.1-1 illustrates the downlink power to be applied for the 2 cells at various time instants of the test execution. Column marked "T0" denotes the initial conditions, while column marked "T1" is to be applied subsequently. The exact instants on which these values shall be applied are described in the texts in this clause.
Table 8.6.2.1-1
Parameter |
Unit |
Cell 1 |
Cell 2 |
||
T0 |
T1 |
T0 |
T1 |
||
UTRA RF Channel Number |
Mid Range Test Frequency |
Mid Range Test Frequency |
|||
CPICH Ec (FDD) |
dBm/3.84MHz |
-60 |
-69 |
-69 |
-60 |
P-CCPCH RSCP (TDD) |
dBm |
-60 |
-69 |
-69 |
-60 |
The UE is in CELL_DCH state of cell 1. SS transmits a LOGGING MEASUREMENT CONFIGURATION message to the UE to configure logged measurements.
The SS transmits a RRC CONNECTION RELEASE message to release the RRC connection.
The UE transmits a RRC CONNECTION RELEASE COMPLETE message and enters idle mode.
The SS waits 5s to allow UE to activate logging.
SS configures its downlink transmission power settings according to columns "T1" in Table 8.6.2.1-1.
The UE re-selects to Cell2 and performs Routing area update procedure. After completion of this procedure the UE is brought to idle mode and SS sends a paging message to the UE. The UE transmits a RRC CONNECTION REQUEST message and SS respond by transmitting a RRC CONNECTION SETUP. The UE transmits a RRC CONNECTION SETUP COMPLETE message with IE “Logged Meas Available” present.
SS transmits a UE INFORMATION REQUEST message with IE "Logged Measurements Report Request" present.
UE shall transmits a UE INFORMATION REPONSE message, and include IE "Logged Measurement Info-FDD" or "Logged Measurement Info-TDD".
Expected Sequence
Step |
Direction |
Message |
Comment |
|
---|---|---|---|---|
UE |
SS |
|||
1 |
<– |
LOGGING MEASUREMENT CONFIGURATION |
||
2 |
<– |
RRC CONNECTION RELEASE |
SS transmits a RRC CONNECTION RELEASE message to release the RRC connection. |
|
3 |
–> |
RRC CONNECTION RELEASE COMPLETE |
UE confirms the connection release and returns to Idle mode. |
|
4 |
Wait 5s to allow UE to activate logging. |
|||
5 |
– |
– |
SS applies the downlink transmission power settings, according to the values in columns "T1" of table 8.6.2.1-1. The UE shall find that the cell 2 is better and attempt to perform a cell reselection. |
|
6 |
– |
– |
The UE re-selects to Cell2 and performs Routing area update procedure. After completion of this procedure the UE is brought to idle mode. |
|
7 |
<– |
Paging |
SS transmits a Paging message on Cell 2. |
|
8 |
–> |
RRC CONNECTION REQUEST |
The UE transmits an RRC CONNECTION REQUEST message. |
|
9 |
<– |
RRC CONNECTION SETUP |
SS transmit an RRC CONNECTION SETUP message. |
|
10 |
–> |
RRC CONNECTION SETUP COMPLETE |
The UE shall transmit an RRC CONNECTION SETUP COMPLETE message with IE “Logged Meas Available” present. |
|
10A |
–> |
RRC: INITIAL DIRECT TRANSFER NAS: SERVICE REQUEST |
The UE transmits SERVICE REQUEST message. |
|
10B |
Steps 6 to 9 defined in TS34.108 clause 7.2.4.2 occurs to complete the service request procedure. |
|||
11 |
<– |
UE INFORMATION REQUEST |
SS transmits a UE INFORMATION REQUEST message with IE" Logged Measurements Report Request" set to “true”. |
|
12 |
–> |
UE INFORMATION RESPONSE |
UE shall transmit a UE INFORMATION RESPONSE message. |
Specific Message Contents
All messages have the same content as defined in 34.108 clause 9 with the following exceptions:
LOGGING MEASUREMENT CONFIGURATION (Step 1)
Information Element |
Value/remark |
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged ANR configuration Info |
|
– Absolute Time Info |
Set to value corresponding to the absolute time when the message is sent |
– Logging Duration |
10 min |
– Logging Interval |
|
– Trace reference |
|
– PLMN Identity |
Same as MIB |
– Trace ID |
‘0EF’H |
-Trace recording session |
‘1A’H |
– TCE Id |
‘5’H |
– CHOICE Area Configuration |
Not present |
RRC CONNECTION SETUP COMPLETE (step 9)
Information Element |
Value/remark |
Message Type |
|
RRC transaction identifier |
The value of this IE is checked to see that it matches the value of the same IE transmitted in the downlink RRC CONNECTION SETUP message. |
Logged Meas Available |
True |
UE INFORMATION REQUEST (Step 11)
Information Element |
Value/remark |
---|---|
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Measurements Report Request |
TRUE |
Logged ANR Report Request |
Not Present |
UE INFORMATION RESPONSE (FDD) (Step 12)
Information Element |
Value/remark |
---|---|
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Meas Report |
|
– Absolute Time Info |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace reference |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace recording session |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– TCE Id |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– CHOICE mode |
FDD |
– List of measurements FDD |
At least 1 entry where at least one entry complies to entry with index ‘x’ below. |
– Logged Measurement Info-FDD[x] |
|
– Relative Time Stamp[x] |
Checked to be present with a value bigger than 0. |
– Logged Measurements Serving Cell[x] |
|
– Cell ID[x] |
Cell 1 |
– Primary CCPCH RSCP[x] |
(0..91) |
– CPICH Ec/N0 |
(0..49) |
– Logged Measurements Intra Frequency list[x] |
Only 1 intra Frequency cell |
– Primary CPICH info |
Set to the scrambling code for cell 2 |
– CPICH RSCP |
(0..91) |
– CPICH Ec/N0 |
(0..49) |
– Logged Meas Available |
Not checked |
UE INFORMATION RESPONSE (TDD) (Step 12)
Information Element |
Value/remark |
---|---|
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Meas Report |
|
– Absolute Time Info |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace reference |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace recording session |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– TCE Id |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– CHOICE mode |
TDD |
– List of measurements TDD |
At least 1 entry where at least one entry complies to entry with index ‘x’ below. |
– Logged Measurement Info-TDD[x] |
|
– Relative Time Stamp[x] |
Checked to be present with a value bigger than 0. |
– Logged Measurements Serving Cell[x] |
|
– Cell ID |
Cell 1 |
– Primary CCPCH RSCP |
(0..91) |
– Logged Measurements Intra Frequency list[x] |
Only 1 intra Frequency cell |
– Cell parameters Id |
Cell parameter Id of Cell 2 |
– Primary CCPCH RSCP |
(0..91) |
– Logged Meas Available |
Not checked |
8.6.2.1.5 Test requirement
At step 10 the UE shall transmit a RRC CONNECTION SETUP COMPLETE message on uplink DCCH including the IE “Logged Meas Available” (TP3).
At step 12 the UE shall transmit a UE INFORMATION RESPONSE message includes IE “Logged Meas Report" with logged Measurements of Cell 2 in the “Logged Measurements Intra Frequency Neighbouring Cells list” with the IE Absolute Time Info set equal to the value configured when the logged measurement configuration was received and the Relative Time Stamp indicating a value bigger than 0 indicating the elapsed time since the logged measurement configuration was received (TP1, TP2, TP4).
8.6.2.1a Logged MDT / Intra-frequency measurement, logging and reporting / Idle mode/PLMN list
8.6.2.1a.1 Definition
8.6.2.1a.2 Conformance requirement
[TS 25.304, clause 5.7 (TP1, TP2)]
The UE may be configured to perform logging of measurement results in idle mode, CELL_PCH and URA_PCH state with LOGGING MEASUREMENT CONFIGURATION message specified in TS 25.331 [4]. This configuration is valid while the logging duration timer is running.
If the configuration of logged measurements is valid, the UE shall perform logging of measurement results if all of the following conditions are met:
– the UE is in camped normally state in idle mode, CELL_PCH or URA_PCH state;
– the RPLMN of the UE is present in the MDT PLMN identity list, if received in the LOGGING MEASUREMENT CONFIGURATION message, or the RPLMN of the UE is the same as the RPLMN at the point of time of LOGGING MEASUREMENT CONFIGURATION message reception
– the UE is camped on a cell belonging to Area Configuration (see TS 25.331 [4]), if configured;
– the UE is camped on the RAT where the logged measurement configuration was received.
Otherwise, the logging of measurement results shall be suspended.
NOTE: Even if logging of measurement results is suspended, the logging duration timer and time stamp will continue, and the logged measurement configuration and corresponding log are kept.
[TS 25.331, clause 8.1.3.6 (TP1)]
The UE shall compare the value of the IE "Initial UE identity" in the received RRC CONNECTION SETUP message with the value of the variable INITIAL_UE_IDENTITY.
If the values are different, the UE shall:
1> ignore the rest of the message.
If the values are identical, the UE shall:
…
1> submit an RRC CONNECTION SETUP COMPLETE message to the lower layers on the uplink DCCH after successful state transition per subclause 8.6.3.3, with the contents set as specified below:
…
2> if an IE "Logged Measurement Info-FDD" or "Logged Measurement Info-TDD" in variable LOGGED_MEAS_REPORT_VARIABLE is present and registered PLMN is present in the IE "PLMN Identity List" stored in variable LOGGED_MEAS_REPORT_VARIABLE:
3> include IE "Logged Meas Available".
…
When the RRC CONNECTION SETUP COMPLETE message has been submitted to lower layers for transmission the UE shall:
…
[TS 25.331, clause 8.5.64.3 (TP2)]
UE Shall:
1> if IE "Logged Measurements Report Request" is present:
2> if Registered PLMN is present in the IE "PLMN Identity List" stored in variable LOGGED_MEAS_REPORT_VARIABLE:
3> if an IE "Logged Measurement Info-FDD" or "Logged Measurement Info-TDD" in variable LOGGED_MEAS_REPORT_VARIABLE is present:
- set IE "Logged Meas Report" in the UE INFORMATION RESPONSE as follows:
5> include the IE "Absolute Time Info" and set it to the value of the IE "Absolute Time Info" in the variable LOGGED_MEAS_REPORT_VARIABLE;
5> include the IE "Trace reference" and set it to the value of IE "Trace reference" in the variable LOGGED_MEAS_REPORT_VARIABLE;
5> include the IE "Trace recording session" and set it to the value of the IE "Trace recording session" in the variable LOGGED_MEAS_REPORT_VARIABLE;
5> include the IE "TCE Id" and set it to the value of IE "TCE Id" in the variable LOGGED_MEAS_REPORT_VARIABLE;
5> include the IEs "Logged Measurement Info-FDD" or "Logged Measurement Info-TDD" and set it to include, in the same order as logged, one or more entries from LOGGED_MEAS_REPORT_VARIABLE;
5> clear the logged measurement results included in the list of IEs "Logged Measurement Info-FDD" or "Logged Measurement Info-TDD" from LOGGED_MEAS_REPORT_VARIABLE;
5> if the variable LOGGED_MEAS_REPORT_VARIABLE is not empty:
6> include IE "Logged Meas Available";
2> transmit a UE INFORMATION RESPONSE message on the uplink DCCH using AM RLC.
…
Reference
3GPP TS 25.304 clause 5.7 and TS 25.331 clauses 8.1.3.6, 8.5.64.3,
8.6.2.1a.3 Test Purpose
1. Verify indication of availability of Logged MDT measurements at RRC connection establishment in the cell that belongs to the PLMN included in LOGGING MEASUREMENT CONFIGURATION message.
2. Verify that Logged Meas Report (logged in idle mode) is reported in UE INFORMATION RESPONSE message.
8.6.2.1a.4 Method of test
Initial Condition
System Simulator: 2 cells, Cell 1 and Cell 2 are active.
UE: PS-DCCH+DTCH_DCH (state 6-10) in Cell 1 as specified in clause 7.4 of TS 34.108, the Attach Accept message in P2 procedure includes PLMN2 in the equivalent PLMN list.
Test Procedure
Table 8.6.2.1a-1 illustrates the downlink power to be applied for the 2 cells at various time instants of the test execution. Column marked "T0" denotes the initial conditions, while column marked "T1" is to be applied subsequently. The exact instants on which these values shall be applied are described in the texts in this clause.
Table 8.6.2.1a-1
Parameter |
Unit |
Cell 1 |
Cell 2 |
||
T0 |
T1 |
T0 |
T1 |
||
UTRA RF Channel Number |
Mid Range Test Frequency |
Mid Range Test Frequency |
|||
CPICH Ec (FDD) |
dBm/3.84MHz |
-60 |
-69 |
-69 |
-60 |
P-CCPCH RSCP (TDD) |
dBm |
-60 |
-69 |
-69 |
-60 |
PLMN |
PLMN 1 |
PLMN 2 |
The UE is in CELL_DCH state of cell 1. SS transmits a LOGGING MEASUREMENT CONFIGURATION message to the UE to configure logged measurements.
The SS transmits a RRC CONNECTION RELEASE message to release the RRC connection.
The UE transmits a RRC CONNECTION RELEASE COMPLETE message and enters idle mode
The SS waits 5s to allow UE to activate logging.
SS configures its downlink transmission power settings according to columns "T1" in Table 8.6.2.1a-1
The UE transmits a RRC CONNECTION REQUEST message and SS respond by transmitting a RRC CONNECTION SETUP. The UE transmits a RRC CONNECTION SETUP COMPLETE message with IE “Logged Meas Available” present.
Complete ROUTING AREA UPDATE procedure.
SS transmits a UE INFORMATION REQUEST message with IE "Logged Measurements Report Request" present.
UE shall transmits a UE INFORMATION REPONSE message, and include IE "Logged Measurement Info-FDD" or "Logged Measurement Info-TDD".
Expected Sequence
Step |
Direction |
Message |
Comment |
|
---|---|---|---|---|
UE |
SS |
|||
1 |
<– |
LOGGING MEASUREMENT CONFIGURATION |
||
2 |
<– |
RRC CONNECTION RELEASE |
SS transmits a RRC CONNECTION RELEASE message to release the RRC connection. |
|
3 |
–> |
RRC CONNECTION RELEASE COMPLETE |
UE confirms the connection release and returns to Idle mode. |
|
4 |
– |
– |
Wait 5s to allow UE to activate logging. |
|
5 |
– |
– |
SS applies the downlink transmission power settings, according to the values in columns "T1" of table 8.6.2.1a-1. The UE shall find that the cell 2 is better and attempt to perform a cell reselection. |
|
6 |
–> |
RRC CONNECTION REQUEST |
The UE transmits an RRC CONNECTION REQUEST message. |
|
7 |
<– |
RRC CONNECTION SETUP |
SS transmit an RRC CONNECTION SETUP message. |
|
8 |
–> |
RRC CONNECTION SETUP COMPLETE |
The UE shall transmit an RRC CONNECTION SETUP COMPLETE message with IE “Logged Meas Available” present. |
|
9 |
–> |
RRC: INITIAL DIRECT TRANSFER NAS: ROUTING AREA UPDATE REQUEST |
The UE transmits a ROUTING AREA UPDATE REQUEST message. |
|
10 |
<– |
RRC: DOWNLINK DIRECT TRANSFER NAS: ROUTING AREA UPDATE ACCEPT |
The SS transmits a ROUTING AREA UPDATE ACCEPT message. |
|
11 |
–> |
RRC: UPLINK DIRECT TRANSFER NAS: ROUTING AREA UPDATE COMPLETE |
The UE transmits a ROUTING AREA UPDATE COMPLETE message. |
|
12 |
<– |
UE INFORMATION REQUEST |
SS transmits a UE INFORMATION REQUEST message with IE" Logged Measurements Report Request" set to “true”. |
|
13 |
–> |
UE INFORMATION RESPONSE |
UE shall transmit a UE INFORMATION RESPONSE message. |
Specific Message Contents
All messages have the same content as defined in 34.108 clause 9 with the following exceptions:
LOGGING MEASUREMENT CONFIGURATION (Step 1)
Information Element |
Value/remark |
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Measurements Configuration Info |
|
– Absolute Time Info |
Set to value corresponding to the absolute time when the message is sent |
– Logging Duration |
10 min |
– Logging Interval |
2.56 |
– Trace reference |
|
– PLMN Identity |
Same as MIB |
– Trace ID |
‘0EF’H |
-Trace recording session |
‘1A’H |
– TCE Id |
‘5’H |
– CHOICE Area Configuration |
Not present |
– PLMN Identity List |
|
– PLMN Identity |
PLMN2 |
RRC CONNECTION SETUP COMPLETE (step 8)
Information Element |
Value/remark |
Message Type |
|
RRC transaction identifier |
The value of this IE is checked to see that it matches the value of the same IE transmitted in the downlink RRC CONNECTION SETUP message. |
Logged Meas Available |
True |
UE INFORMATION REQUEST (Step 12)
Information Element |
Value/remark |
---|---|
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Measurements Report Request |
TRUE |
Logged ANR Report Request |
Not Present |
UE INFORMATION RESPONSE (FDD) (Step 13)
Information Element |
Value/remark |
---|---|
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Meas Report |
|
– Absolute Time Info |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace reference |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace recording session |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– TCE Id |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– CHOICE mode |
FDD |
– List of measurements FDD |
At least 1 entry where at least one entry complies to entry with index ‘x’ below. |
– Logged Measurement Info-FDD[x] |
|
– Relative Time Stamp[x] |
Checked to be present with a value bigger than 0. |
– Logged Measurements Serving Cell[x] |
|
– PLMN Identity |
PLMN 1 |
– Cell ID[x] |
Cell 1 |
– Primary CCPCH RSCP[x] |
(0..91) |
– CPICH Ec/N0 |
(0..49) |
– Logged Measurements Intra Frequency list[x] |
Only 1 intra Frequency cell |
– Primary CPICH info |
Set to the scrambling code for cell 2 |
– CPICH RSCP |
(0..91) |
– CPICH Ec/N0 |
(0..49) |
– Logged Meas Available |
Not checked |
UE INFORMATION RESPONSE (TDD) (Step 13)
Information Element |
Value/remark |
---|---|
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Meas Report |
|
– Absolute Time Info |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace reference |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace recording session |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– TCE Id |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– CHOICE mode |
TDD |
– List of measurements TDD |
At least 1 entry where at least one entry complies to entry with index ‘x’ below. |
– Logged Measurement Info-TDD[x] |
|
– Relative Time Stamp[x] |
Checked to be present with a value bigger than 0. |
– Logged Measurements Serving Cell[x] |
|
– PLMN Identity |
PLMN 1 |
– Cell ID |
Cell 1 |
– Primary CCPCH RSCP |
(0..91) |
– Logged Measurements Intra Frequency list[x] |
Only 1 intra Frequency cell |
– Cell parameters Id |
Cell parameter Id of Cell 2 |
– Primary CCPCH RSCP |
(0..91) |
– Logged Meas Available |
Not checked |
8.6.2.1a.5 Test requirement
At step 8 the UE shall transmit a RRC CONNECTION SETUP COMPLETE message on uplink DCCH including the IE “Logged Meas Available” (TP1).
At step 13 the UE shall transmit a UE INFORMATION RESPONSE message includes IE “Logged Meas Report" with logged Measurements of Cell 2 in the “Logged Measurements Intra Frequency Neighbouring Cells list” (TP2).
8.6.2.2 Logged MDT / Intra-frequency measurement, logging and reporting / CELL_PCH
8.6.2.2.1 Definition
8.6.2.2.2 Conformance requirement
[TS 25.304, clause 5.7 (TP1)]
The UE may be configured to perform logging of measurement results in idle mode, CELL_PCH and URA_PCH state with LOGGING MEASUREMENT CONFIGURATION message specified in TS 25.331 [4]. This configuration is valid while the logging duration timer is running.
If the configuration of logged measurements is valid, the UE shall perform logging of measurement results if all of the following conditions are met:
– the UE is in camped normally state in idle mode, CELL_PCH or URA_PCH state;
– RPLMN of the UE is the same as the RPLMN at the point of time of LOGGING MEASUREMENT CONFIGURATION message reception
– the UE is camped on a cell belonging to Area Configuration (see TS 25.331 [4]), if configured;
– the UE is camped on the RAT where the logged measurement configuration was received.
Otherwise, the logging of measurement results shall be suspended.
NOTE: Even if logging of measurement results is suspended, the logging duration timer and time stamp will continue, and the logged measurement configuration and corresponding log are kept.
[TS 25.331, clause 8.3.1.3 (TP3)]
In case of cell update procedure the UE shall transmit a CELL UPDATE message.
…
The UE shall set the IEs in the CELL UPDATE message as follows:
…
1> if an IE "Logged Measurement Info-FDD" or "Logged Measurement Info-TDD" in variable LOGGED_MEAS_REPORT_VARIABLE is present and registered PLMN is the same as the IE "PLMN Identity" stored in variable LOGGED_MEAS_REPORT_VARIABLE:
2> include IE "Logged Meas Available".
…
[TS 25.331, clause 8.5.63.3 (TP1)]
Upon receiving the LOGGING MEASUREMENT CONFIGURATION message the UE shall:
1> if IE "Logged Measurements Configuration Info" is present:
2> if stored, discard the existing logged measurement configuration as well as the logged measurement information as specified in 8.5.66;
2> store the received IEs "Logging Duration", "Logging Interval", "Area Configuration" if included in IE "Logged Measurements Configuration Info" in variable LOGGED_MEAS_CONFIG and IEs "Absolute Time Info", "Trace reference", "Trace recording session" and "TCE Id" in variable LOGGED_MEAS_REPORT_VARIABLE;
2> store the current Registered PLMN in the IE "PLMN Identity" in variable LOGGED_MEAS_REPORT_VARIABLE;
2> start timer T326 with the timer value set to the IE "Logging Duration".
NOTE: The UE shall not stop timer T326 unless explicitly stated when it moves to another RAT.
…
[TS 25.331, clause 8.5.64.3 (TP2)]
UE Shall:
1> if IE "Logged Measurements Report Request" is present:
2> if Registered PLMN is the same as the IE "PLMN Identity" stored in variable LOGGED_MEAS_REPORT_VARIABLE:
3> if an IE "Logged Measurement Info-FDD" or "Logged Measurement Info-TDD" in variable LOGGED_MEAS_REPORT_VARIABLE is present:
- set IE "Logged Meas Report" in the UE INFORMATION RESPONSE as follows:
5> include the IE "Absolute Time Info" and set it to the value of the IE "Absolute Time Info" in the variable LOGGED_MEAS_REPORT_VARIABLE;
5> include the IE "Trace reference" and set it to the value of IE "Trace reference" in the variable LOGGED_MEAS_REPORT_VARIABLE;
5> include the IE "Trace recording session" and set it to the value of IE "Trace recording session" in the variable LOGGED_MEAS_REPORT_VARIABLE;
5> include the IE "TCE Id" and set it to the value of IE "TCE Id" in the variable LOGGED_MEAS_REPORT_VARIABLE;
5> include the IEs "Logged Measurement Info-FDD" or "Logged Measurement Info-TDD" and set it to include, in the same order as logged, one or more entries from LOGGED_MEAS_REPORT_VARIABLE;
5> clear the logged measurement results included in the list of IEs "Logged Measurement Info-FDD" or "Logged Measurement Info-TDD" from LOGGED_MEAS_REPORT_VARIABLE;
5> if the variable LOGGED_MEAS_REPORT_VARIABLE is not empty:
6> include IE "Logged Meas Available";
2> transmit a UE INFORMATION RESPONSE message on the uplink DCCH using AM RLC.
…
[TS 25.331, clause 8.5.65 (TP1, TP2)]
When in idle mode, CELL_PCH or URA_PCH state and Logged Measurements has been configured, the UE shall:
1> Store the available measurements according to the logged measurements configuration in LOGGED_MEAS_CONFIG variable as specified in subclause 8.5.65.2.
[TS 25.331, clause 8.5.65.2 (TP1, TP2)]
While T326 is running, the UE shall:
1> perform this logging in accordance with the following:
2> perform the logging while camping normally on an UTRA cell and the RPLMN of the UE is the same as the PLMN Identity stored in LOGGED_MEAS_REPORT_VARIABLE and, if the IE "Area Configuration" is present in variable LOGGED_MEAS_CONFIG, that is part of the concerned area;
2> perform the logging at regular intervals, as defined by the IE "Logging Interval" in variable LOGGED_MEAS_CONFIG;
2> when adding a logged measurement entry in variable LOGGED_MEAS_REPORT_VARIABLE, include the fields in accordance with the following:
3> set the IE "Relative Time Stamp" to indicate time relative to the moment at which the logged measurement configuration was received;
3> if GNSS location information became available during the last logging interval:
4> if the UE has been able to calculate a 3-dimensional position:
5> set IE "Ellipsoid point with altitude" to include the location coordinates;
4>else:
5> set IE "Ellipsoid point" to include the location coordinates:
3> set the IE "Cell ID" to indicate cell identity of the cell the UE is camping on obtained from system information;
3> set the IE "CPICH Ec/N0" and "CPICH RSCP" to include measured quantities of the cell that the UE is camping on for UTRA FDD;
3> set the "P-CCPCH RSCP" to include measured quantities for the cell that the UE is camping on for UTRA 1.28 Mcps TDD;
3> set the IE "Logged Measurements Intra Frequency Neighbouring Cells list", "Logged Measurements Inter Frequency list", "Logged Measurements E-UTRA frequency list", in order of decreasing ranking quantity as used for cell re-selection in each frequency for at most the following number of neighbouring cells; 6 intra-frequency and 3 inter-frequency neighbours per frequency as well as 3 inter-RAT neighbours, per frequency per RAT;
3> set the IE "Logged Measurements GSM Neighbouring Cells list" in order of decreasing RXLEV.
NOTE: The UE includes, only once, the latest available results of the measurement performed for cell reselection, which are performed in accordance with the regular performance requirements as specified in [19].
2> when the memory reserved for the logging of measurements becomes full, stop timer T326 and performs the same actions as performed upon expiry of T326, as specified in 8.5.63.4.
Reference
3GPP TS 25.304 clause 5.7 and TS 25.331 clauses 8.3.1.3, 8.5.63, 8.5.65, 8.5.65.2.
8.6.2.2.3 Test Purpose
1. Verify logging of configured Logged MDT measurements in CELL_PCH state.
2. Verify logging and reporting of Logged MDT Intra-frequency measurements.
3. Verify indication of availability of Logged MDT measurements in CELL UPDATE message.
8.6.2.2.4 Method of test
Initial Condition
System Simulator: 2 cells, Cell 1 and Cell 2 are active.
SYSTEM INFORMATION BLOCK TYPE 4 (see specific message contents).
UE: PS-DCCH+DTCH_DCH (state 6-10) in Cell 1 as specified in clause 7.4 of TS 34.108.
Test Procedure
Table 8.6.2.2-1 illustrates the downlink power to be applied for the 2 cells at various time instants of the test execution. Column marked "T0" denotes the initial conditions, while column marked "T1" is to be applied subsequently. The exact instants on which these values shall be applied are described in the texts in this clause.
Table 8.6.2.2-1
Parameter |
Unit |
Cell 1 |
Cell 2 |
||
T0 |
T1 |
T0 |
T1 |
||
UTRA RF Channel Number |
Mid Range Test Frequency |
Mid Range Test Frequency |
|||
CPICH Ec (FDD) |
dBm/3.84MHz |
-60 |
-69 |
-69 |
-60 |
P-CCPCH RSCP (TDD) |
dBm |
-60 |
-69 |
-69 |
-60 |
The UE is in CELL_DCH state of cell 1. SS transmits a LOGGING MEASUREMENT CONFIGURATION message to the UE to configure logged measurements.
SS transmits a PHYSICAL CHANNEL RECONFIGURATION message, which invokes the UE to transit from CELL_DCH to CELL_PCH.
The UE transmits a PHYSICAL CHANNEL RECONFIGURATION COMPLETE message and enters CELL_PCH state.
Wait 5s to allow UE to activate logging.
SS configures its downlink transmission power settings according to columns "T1" in Table 8.6.2.2-1
When the UE detects the presence of cell 2, it moves to CELL_FACH state and transmits a CELL UPDATE message on the uplink CCCH. The IE "Logged Meas Available" shall be present in the message.
Upon reception of CELL_UPDATE message, SS replies with a CELL UPDATE CONFIRM message with the IE "RRC State Indicator" set to "CELL_DCH".
SS transmits a UE INFORMATION REQUEST message, and the IE "Logged Measurements Report Request" is present.
UE shall transmits a UE INFORMATION REPONSE message, and include IE "Logged Measurement Info-FDD" or "Logged Measurement Info-TDD".
Expected Sequence
Step |
Direction |
Message |
Comment |
|
---|---|---|---|---|
UE |
SS |
|||
1 |
|
LOGGING MEASUREMENT CONFIGURATION |
||
1a |
SS waits for 200msec to ensure UE acts upon Step 1 before proceeding to next step. |
|||
2 |
|
PHYSICAL CHANNEL RECONFIGURATION |
The IE "RRC state indicator" is set to "CELL_PCH". |
|
3 |
|
PHYSICAL CHANNEL RECONFIGURATION COMPLETE |
The UE sends this message before it completes state transition. |
|
4 |
Wait 5s to allow UE to activate logging. |
|||
5 |
SS applies the downlink transmission power settings, according to the values in columns "T1" of table 8.6.2.2-1. The UE shall find that the cell 2 is better and attempt to perform a cell reselection. |
|||
6 |
|
CELL UPDATE |
The UE moves to CELL_FACH state and transmits this message with the IE "Logged Meas Available" set as true |
|
7 |
|
CELL UPDATE CONFIRM |
IE "RRC State Indicator" is set to "CELL_DCH". |
|
7a |
|
PHYSICAL CHANNEL RECONFIGURATION COMPLETE |
||
8 |
|
UE INFORMATION REQUEST |
SS transmits a UE INFORMATION REQUEST message with IE" Logged Measurements Report Request" set to “true”. |
|
9 |
|
UE INFORMATION RESPONSE |
UE shall transmit a UE INFORMATION RESPONSE message. |
Specific Message Contents
SYSTEM INFORMATION BLOCK TYPE 4
Use the same message type found in clause 6.1.0b of TS 34.108, with the following exceptions for Cell 1:
– Qqualmin |
-16 |
All messages have the same content as defined in 34.108 clause 9 with the following exceptions:
LOGGING MEASUREMENT CONFIGURATION (Step 1)
Information Element |
Value/remark |
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged ANR configuration Info |
|
– Absolute Time Info |
Set to value corresponding to the absolute time when the message is sent |
– Logging Duration |
10 min |
– Logging Interval |
2.57 |
– Trace reference |
|
– PLMN Identity |
Same as MIB |
– Trace ID |
‘0EF’H |
-Trace recording session |
‘1A’H |
– TCE Id |
‘5’H |
– CHOICE Area Configuration |
Not present |
PHYSICAL CHANNEL RECONFIGURATION (Steps 2)
Use the same message sub-type titled "Packet to CELL_PCH from CELL_DCH in PS" in TS 34.108 clause 9 with following exceptions.
Information Element |
Value/remark |
Downlink information for each radio link |
|
-Primary CPICH info |
|
-Primary scrambling code |
100 |
CELL UPDATE (Step 6)
The same message found in TS 34.108 clause 9 shall be transmitted by the UE on the uplink CCCH, with the exception of the following IEs:
Information Element |
Value/remark |
U-RNTI |
|
– SRNC Identity |
Check to see if set to ‘0000 0000 0001’ |
– S-RNTI |
Check to see if set to ‘0000 0000 0000 0000 0001’ |
Cell Update Cause |
Check to see if set to ‘Cell Re-selection’ |
Logged Meas Available |
TRUE |
CELL UPDATE CONFIRM (Step 7)
Use the same message sub-type found in TS 34.108, clause 9 with the following exceptions:
Information Element |
Value/remark |
RRC State indicator |
CELL_DCH |
CHOICE channel requirement |
|
Uplink DPCH info |
Same as the set defined in RADIO BEARER SETUP message found in TS 34.108 clause 9 under condition A4. |
Downlink information common for all radio links |
Same as the set defined in RADIO BEARER SETUP message found in TS 34.108 clause 9 under condition A4. |
Downlink information per radio link list |
Same as the set defined in RADIO BEARER SETUP message found in TS 34.108 clause 9 under condition A4. |
UE INFORMATION REQUEST (Step 8)
Information Element |
Value/remark |
---|---|
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Measurements Report Request |
TRUE |
Logged ANR Report Request |
Not Present |
UE INFORMATION RESPONSE (FDD) (Step 9)
Information Element |
Value/remark |
---|---|
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Meas Report |
|
– Absolute Time Info |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace reference |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace recording session |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– TCE Id |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– CHOICE mode |
FDD |
– List of measurements FDD |
At least 1 entry where at least one entry complies to entry with index ‘x’ below. |
– Logged Measurement Info-FDD[x] |
|
– Relative Time Stamp[x] |
Not checked |
– Logged Measurements Serving Cell[x] |
|
– Cell ID[x] |
Cell 1 |
– Primary CCPCH RSCP[x] |
(0..91) |
– CPICH Ec/N0 |
(0..49) |
– Logged Measurements Intra Frequency list[x] |
Only 1 intra Frequency cell |
– Primary CPICH info |
Set to the scrambling code for cell 2 |
– CPICH RSCP |
(0..91) |
– CPICH Ec/N0 |
(0..49) |
– Logged Meas Available |
Not checked |
UE INFORMATION RESPONSE (TDD) (Step 9)
Information Element |
Value/remark |
---|---|
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Meas Report |
|
– Absolute Time Info |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace reference |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace recording session |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– TCE Id |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– CHOICE mode |
TDD |
– List of measurements TDD |
At least 1 entry where at least one entry complies to entry with index ‘x’ below. |
– Logged Measurement Info-TDD[x] |
|
– Relative Time Stamp[x] |
Not checked |
– Logged Measurements Serving Cell[x] |
|
– Cell ID |
Cell 1 |
– Primary CCPCH RSCP |
(0..91) |
– Logged Measurements Intra Frequency list[x] |
Only 1 intra Frequency cell |
– Cell parameters Id |
Cell parameter Id of Cell 2 |
– Primary CCPCH RSCP |
(0..91) |
– Logged Meas Available |
Not checked |
8.6.2.2.5 Test requirement
At step 6 the UE shall transmit a CELL UPDATE message on uplink DCCH including the IE “Logged Meas Available” (TP3).
At step 9 the UE shall transmit a UE INFORMATION RESPONSE message includes IE “Logged Meas Report" with logged Measurements of Cell 2 in the “Logged Measurements Intra Frequency Neighbouring Cells list” (TP1, TP2).
8.6.2.2a Logged MDT / Intra-frequency measurement, logging and reporting / CELL_PCH/PLMN list
8.6.2.2a.1 Definition
8.6.2.2a.2 Conformance requirement
[TS 25.304, clause 5.7 (TP1, TP2)]
The UE may be configured to perform logging of measurement results in idle mode, CELL_PCH and URA_PCH state with LOGGING MEASUREMENT CONFIGURATION message specified in TS 25.331 [4]. This configuration is valid while the logging duration timer is running.
If the configuration of logged measurements is valid, the UE shall perform logging of measurement results if all of the following conditions are met:
– the UE is in camped normally state in idle mode, CELL_PCH or URA_PCH state;
– the RPLMN of the UE is present in the MDT PLMN identity list, if received in the LOGGING MEASUREMENT CONFIGURATION message, or the RPLMN of the UE is the same as the RPLMN at the point of time of LOGGING MEASUREMENT CONFIGURATION message reception
– the UE is camped on a cell belonging to Area Configuration (see TS 25.331 [4]), if configured;
– the UE is camped on the RAT where the logged measurement configuration was received.
Otherwise, the logging of measurement results shall be suspended.
NOTE: Even if logging of measurement results is suspended, the logging duration timer and time stamp will continue, and the logged measurement configuration and corresponding log are kept.
[TS 25.331, clause 8.3.1.3 (TP1)]
In case of cell update procedure the UE shall transmit a CELL UPDATE message.
…
The UE shall set the IEs in the CELL UPDATE message as follows:
…
1> if an IE "Logged Measurement Info-FDD" or "Logged Measurement Info-TDD" in variable LOGGED_MEAS_REPORT_VARIABLE is present and registered PLMN is the same as the IE "PLMN Identity" stored in variable LOGGED_MEAS_REPORT_VARIABLE:
2> include IE "Logged Meas Available".
…
[TS 25.331, clause 8.5.64.3 (TP2)]
UE Shall:
1> if IE "Logged Measurements Report Request" is present:
2> if Registered PLMN is present in the IE "PLMN Identity List" stored in variable LOGGED_MEAS_REPORT_VARIABLE:
3> if an IE "Logged Measurement Info-FDD" or "Logged Measurement Info-TDD" in variable LOGGED_MEAS_REPORT_VARIABLE is present:
- set IE "Logged Meas Report" in the UE INFORMATION RESPONSE as follows:
5> include the IE "Absolute Time Info" and set it to the value of the IE "Absolute Time Info" in the variable LOGGED_MEAS_REPORT_VARIABLE;
5> include the IE "Trace reference" and set it to the value of IE "Trace reference" in the variable LOGGED_MEAS_REPORT_VARIABLE;
5> include the IE "Trace recording session" and set it to the value of the IE "Trace recording session" in the variable LOGGED_MEAS_REPORT_VARIABLE;
5> include the IE "TCE Id" and set it to the value of IE "TCE Id" in the variable LOGGED_MEAS_REPORT_VARIABLE;
5> include the IEs "Logged Measurement Info-FDD" or "Logged Measurement Info-TDD" and set it to include, in the same order as logged, one or more entries from LOGGED_MEAS_REPORT_VARIABLE;
5> clear the logged measurement results included in the list of IEs "Logged Measurement Info-FDD" or "Logged Measurement Info-TDD" from LOGGED_MEAS_REPORT_VARIABLE;
5> if the variable LOGGED_MEAS_REPORT_VARIABLE is not empty:
6> include IE "Logged Meas Available";
2> transmit a UE INFORMATION RESPONSE message on the uplink DCCH using AM RLC.
…
Reference
3GPP TS 25.304 clause 5.7 and TS 25.331 clauses 8.3.1.3, 8.5.64.3,
8.6.2.2a.3 Test Purpose
1. Verify indication of availability of Logged MDT measurements obtained in CELL_PCH state at cell update procedure in the cell that belongs to the PLMN included in LOGGING MEASUREMENT CONFIGURATION message.
2. Verify that Logged Meas Report (logged in CELL_PCH state) is reported in UE INFORMATION RESPONSE message.
8.6.2.2a.4 Method of test
Initial Condition
System Simulator: 2 cells, Cell 1 and Cell 2 are active.
UE: PS-DCCH+DTCH_DCH (state 6-10) in Cell 1 as specified in clause 7.4 of TS 34.108, the Attach Accept message in P2 procedure includes PLMN2 in the equivalent PLMN list.
Test Procedure
Table 8.6.2.2a-1 illustrates the downlink power to be applied for the 2 cells at various time instants of the test execution. Column marked "T0" denotes the initial conditions, while column marked "T1" is to be applied subsequently. The exact instants on which these values shall be applied are described in the texts in this clause.
Table 8.6.2.2a-1
Parameter |
Unit |
Cell 1 |
Cell 2 |
||
T0 |
T1 |
T0 |
T1 |
||
UTRA RF Channel Number |
Mid Range Test Frequency |
Mid Range Test Frequency |
|||
CPICH Ec (FDD) |
dBm/3.84MHz |
-60 |
-69 |
-69 |
-60 |
P-CCPCH RSCP (TDD) |
dBm |
-60 |
-69 |
-69 |
-60 |
PLMN |
PLMN 1 |
PLMN 2 |
The UE is in CELL_DCH state of cell 1. SS transmits a LOGGING MEASUREMENT CONFIGURATION message to the UE to configure logged measurements.
SS transmits a PHYSICAL CHANNEL RECONFIGURATION message, which invokes the UE to transit from CELL_DCH to CELL_PCH.
The UE transmits a PHYSICAL CHANNEL RECONFIGURATION COMPLETE message and enters CELL_PCH state.
Wait 5s to allow UE to activate logging.
SS configures its downlink transmission power settings according to columns "T1" in Table 8.6.2.2a-1
When the UE detects the presence of cell 2, it moves to CELL_FACH state and transmits a CELL UPDATE message on the uplink CCCH. The IE "Logged Meas Available" shall be present in the message.
Upon reception of CELL_UPDATE message, SS replies with a CELL UPDATE CONFIRM message with the IE "RRC State Indicator" set to "CELL_DCH".
Completes ROUTING AREA UPDATE procedure.
SS transmits a UE INFORMATION REQUEST message, and the IE "Logged Measurements Report Request" is present.
UE shall transmits a UE INFORMATION REPONSE message, and include IE "Logged Measurement Info-FDD" or "Logged Measurement Info-TDD".
Expected Sequence
Step |
Direction |
Message |
Comment |
|
---|---|---|---|---|
UE |
SS |
|||
1 |
|
LOGGING MEASUREMENT CONFIGURATION |
||
2 |
|
PHYSICAL CHANNEL RECONFIGURATION |
The IE "RRC state indicator" is set to "CELL_PCH". |
|
3 |
|
PHYSICAL CHANNEL RECONFIGURATION COMPLETE |
The UE sends this message before it completes state transition. |
|
4 |
– |
– |
Wait 5s to allow UE to activate logging. |
|
5 |
– |
– |
SS applies the downlink transmission power settings, according to the values in columns "T1" of table 8.6.2.2a-1. The UE shall find that the cell 2 is better and attempt to perform a cell reselection. |
|
6 |
|
CELL UPDATE |
The UE moves to CELL_FACH state and transmits this message with the IE "Logged Meas Available" set as true |
|
7 |
|
CELL UPDATE CONFIRM |
IE "RRC State Indicator" is set to "CELL_DCH". |
|
7a |
|
PHYSICAL CHANNEL RECONFIGURATION COMPLETE |
||
8 |
–> |
RRC: INITIAL DIRECT TRANSFER NAS: ROUTING AREA UPDATE REQUEST |
The UE transmits a ROUTING AREA UPDATE REQUEST message. |
|
9 |
<– |
RRC: DOWNLINK DIRECT TRANSFER NAS: ROUTING AREA UPDATE ACCEPT |
The SS transmits a ROUTING AREA UPDATE ACCEPT message. |
|
10 |
–> |
RRC: UPLINK DIRECT TRANSFER NAS: ROUTING AREA UPDATE COMPLETE |
The UE transmits a ROUTING AREA UPDATE COMPLETE message. |
|
11 |
|
UE INFORMATION REQUEST |
SS transmits a UE INFORMATION REQUEST message with IE" Logged Measurements Report Request" set to “true”. |
|
12 |
|
UE INFORMATION RESPONSE |
UE shall transmit a UE INFORMATION RESPONSE message. |
Specific Message Contents
All messages have the same content as defined in 34.108 clause 9 with the following exceptions:
LOGGING MEASUREMENT CONFIGURATION (Step 1)
Information Element |
Value/remark |
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged ANR configuration Info |
|
– Absolute Time Info |
Set to value corresponding to the absolute time when the message is sent |
– Logging Duration |
10 min |
– Logging Interval |
2.57 |
– Trace reference |
|
– PLMN Identity |
Same as MIB |
– Trace ID |
‘0EF’H |
-Trace recording session |
‘1A’H |
– TCE Id |
‘5’H |
– CHOICE Area Configuration |
Not present |
– PLMN Identity List |
|
– PLMN Identity |
PLMN2 |
PHYSICAL CHANNEL RECONFIGURATION (Steps 2)
Use the same message sub-type titled "Packet to CELL_PCH from CELL_DCH in PS" in TS 34.108 clause 9 with following exceptions:
Information Element |
Value/remark |
Downlink information for each radio link |
|
-Primary CPICH info |
|
-Primary scrambling code |
100 |
CELL UPDATE (Step 6)
The same message found in TS 34.108 clause 9 shall be transmitted by the UE on the uplink CCCH, with the exception of the following IEs:
Information Element |
Value/remark |
U-RNTI |
|
– SRNC Identity |
Check to see if set to ‘0000 0000 0001’ |
– S-RNTI |
Check to see if set to ‘0000 0000 0000 0000 0001’ |
Cell Update Cause |
Check to see if set to ‘Cell Re-selection’ |
Logged Meas Available |
TRUE |
CELL UPDATE CONFIRM (Step 7)
Use the same message sub-type found in TS 34.108, clause 9 with the following exceptions:
Information Element |
Value/remark |
RRC State indicator |
CELL_DCH |
CHOICE channel requirement |
|
Uplink DPCH info |
Same as the set defined in RADIO BEARER SETUP message found in TS 34.108 clause 9 under condition A4. |
Downlink information common for all radio links |
Same as the set defined in RADIO BEARER SETUP message found in TS 34.108 clause 9 under condition A4. |
Downlink information per radio link list |
Same as the set defined in RADIO BEARER SETUP message found in TS 34.108 clause 9 under condition A4. |
UE INFORMATION REQUEST (Step 11)
Information Element |
Value/remark |
---|---|
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Measurements Report Request |
TRUE |
Logged ANR Report Request |
Not Present |
UE INFORMATION RESPONSE (FDD) (Step 12)
Information Element |
Value/remark |
---|---|
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Meas Report |
|
– Absolute Time Info |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace reference |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace recording session |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– TCE Id |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– CHOICE mode |
FDD |
– List of measurements FDD |
At least 1 entry where at least one entry complies to entry with index ‘x’ below. |
– Logged Measurement Info-FDD[x] |
|
– Relative Time Stamp[x] |
Not checked |
– Logged Measurements Serving Cell[x] |
|
– PLMN Identity |
PLMN 1 |
– Cell ID[x] |
Cell 1 |
– Primary CCPCH RSCP[x] |
(0..91) |
– CPICH Ec/N0 |
(0..49) |
– Logged Measurements Intra Frequency list[x] |
Only 1 intra Frequency cell |
– Primary CPICH info |
Set to the scrambling code for cell 2 |
– CPICH RSCP |
(0..91) |
– CPICH Ec/N0 |
(0..49) |
– Logged Meas Available |
Not checked |
UE INFORMATION RESPONSE (TDD) (Step 12)
Information Element |
Value/remark |
---|---|
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Meas Report |
|
– Absolute Time Info |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace reference |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace recording session |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– TCE Id |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– CHOICE mode |
TDD |
– List of measurements TDD |
At least 1 entry where at least one entry complies to entry with index ‘x’ below. |
– Logged Measurement Info-TDD[x] |
|
– Relative Time Stamp[x] |
Not checked |
– Logged Measurements Serving Cell[x] |
|
– PLMN Identity |
PLMN 1 |
– Cell ID |
Cell 1 |
– Primary CCPCH RSCP |
(0..91) |
– Logged Measurements Intra Frequency list[x] |
Only 1 intra Frequency cell |
– Cell parameters Id |
Cell parameter Id of Cell 2 |
– Primary CCPCH RSCP |
(0..91) |
– Logged Meas Available |
Not checked |
8.6.2.2a.5 Test requirement
At step 6 the UE shall transmit a CELL UPDATE message on uplink DCCH including the IE “Logged Meas Available” (TP1).
At step 12 the UE shall transmit a UE INFORMATION RESPONSE message includes IE “Logged Meas Report" with logged Measurements of Cell 2 in the “Logged Measurements Intra Frequency Neighbouring Cells list” (TP2).
8.6.2.3 Logged MDT / Inter-frequency measurement, logging and reporting / URA_PCH
8.6.2.3.1 Definition
8.6.2.3.2 Conformance requirement
[TS 25.304, clause 5.7 (TP1)]
The UE may be configured to perform logging of measurement results in idle mode, CELL_PCH and URA_PCH state with LOGGING MEASUREMENT CONFIGURATION message specified in TS 25.331 [4]. This configuration is valid while the logging duration timer is running.
If the configuration of logged measurements is valid, the UE shall perform logging of measurement results if all of the following conditions are met:
– the UE is in camped normally state in idle mode, CELL_PCH or URA_PCH state;
– RPLMN of the UE is the same as the RPLMN at the point of time of LOGGING MEASUREMENT CONFIGURATION message reception
– the UE is camped on a cell belonging to Area Configuration (see TS 25.331 [4]), if configured;
– the UE is camped on the RAT where the logged measurement configuration was received.
Otherwise, the logging of measurement results shall be suspended.
NOTE: Even if logging of measurement results is suspended, the logging duration timer and time stamp will continue, and the logged measurement configuration and corresponding log are kept.
[TS 25.331, clause 8.3.1.3 (TP3)]
…
In case of URA update procedure the UE shall transmit a URA UPDATE message.
…
The UE shall set the IEs in the URA UPDATE message as follows:
…
1> if an IE "Logged Measurement Info-FDD" or "Logged Measurement Info-TDD" in variable LOGGED_MEAS_REPORT_VARIABLE is present and registered PLMN is the same as the IE "PLMN Identity" stored in variable LOGGED_MEAS_REPORT_VARIABLE:
2> include IE "Logged Meas Available".
…
[TS 25.331, clause 8.5.63.3 (TP1)]
Upon receiving the LOGGING MEASUREMENT CONFIGURATION message the UE shall:
1> if IE "Logged Measurements Configuration Info" is present:
2> if stored, discard the existing logged measurement configuration as well as the logged measurement information as specified in 8.5.66;
2> store the received IEs "Logging Duration", "Logging Interval", "Area Configuration" if included in IE "Logged Measurements Configuration Info" in variable LOGGED_MEAS_CONFIG and IEs "Absolute Time Info", "Trace reference", "Trace recording session" and "TCE Id" in variable LOGGED_MEAS_REPORT_VARIABLE;
2> store the current Registered PLMN in the IE "PLMN Identity" in variable LOGGED_MEAS_REPORT_VARIABLE;
2> start timer T326 with the timer value set to the IE "Logging Duration".
NOTE: The UE shall not stop timer T326 unless explicitly stated when it moves to another RAT.
…
[TS 25.331, clause 8.5.64.3 (TP2)]
UE Shall:
1> if IE "Logged Measurements Report Request" is present:
2> if Registered PLMN is the same as the IE "PLMN Identity" stored in variable LOGGED_MEAS_REPORT_VARIABLE:
3> if an IE "Logged Measurement Info-FDD" or "Logged Measurement Info-TDD" in variable LOGGED_MEAS_REPORT_VARIABLE is present:
- set IE "Logged Meas Report" in the UE INFORMATION RESPONSE as follows:
5> include the IE "Absolute Time Info" and set it to the value of the IE "Absolute Time Info" in the variable LOGGED_MEAS_REPORT_VARIABLE;
5> include the IE "Trace reference" and set it to the value of IE "Trace reference" in the variable LOGGED_MEAS_REPORT_VARIABLE;
5> include the IE "Trace recording session" and set it to the value of IE "Trace recording session" in the variable LOGGED_MEAS_REPORT_VARIABLE;
5> include the IE "TCE Id" and set it to the value of IE "TCE Id" in the variable LOGGED_MEAS_REPORT_VARIABLE;
5> include the IEs "Logged Measurement Info-FDD" or "Logged Measurement Info-TDD" and set it to include, in the same order as logged, one or more entries from LOGGED_MEAS_REPORT_VARIABLE;
5> clear the logged measurement results included in the list of IEs "Logged Measurement Info-FDD" or "Logged Measurement Info-TDD" from LOGGED_MEAS_REPORT_VARIABLE;
5> if the variable LOGGED_MEAS_REPORT_VARIABLE is not empty:
6> include IE "Logged Meas Available";
2> transmit a UE INFORMATION RESPONSE message on the uplink DCCH using AM RLC.
…
[TS 25.331, clause 8.5.65 (TP1, TP2)]
When in idle mode, CELL_PCH or URA_PCH state and Logged Measurements has been configured, the UE shall:
1> Store the available measurements according to the logged measurements configuration in LOGGED_MEAS_CONFIG variable as specified in subclause 8.5.65.2.
[TS 25.331, clause 8.5.65.2 (TP1, TP2)]
While T326 is running, the UE shall:
1> perform this logging in accordance with the following:
2> perform the logging while camping normally on an UTRA cell and the RPLMN of the UE is the same as the PLMN Identity stored in LOGGED_MEAS_REPORT_VARIABLE and, if the IE "Area Configuration" is present in variable LOGGED_MEAS_CONFIG, that is part of the concerned area;
2> perform the logging at regular intervals, as defined by the IE "Logging Interval" in variable LOGGED_MEAS_CONFIG;
2> when adding a logged measurement entry in variable LOGGED_MEAS_REPORT_VARIABLE, include the fields in accordance with the following:
3> set the IE "Relative Time Stamp" to indicate time relative to the moment at which the logged measurement configuration was received;
3> if GNSS location information became available during the last logging interval:
4> if the UE has been able to calculate a 3-dimensional position:
5> set IE "Ellipsoid point with altitude" to include the location coordinates;
4>else:
5> set IE "Ellipsoid point" to include the location coordinates:
3> set the IE "Cell ID" to indicate cell identity of the cell the UE is camping on obtained from system information;
3> set the IE "CPICH Ec/N0" and "CPICH RSCP" to include measured quantities of the cell that the UE is camping on for UTRA FDD;
3> set the "P-CCPCH RSCP" to include measured quantities for the cell that the UE is camping on for UTRA 1.28 Mcps TDD;
3> set the IE "Logged Measurements Intra Frequency Neighbouring Cells list", "Logged Measurements Inter Frequency list", "Logged Measurements E-UTRA frequency list", in order of decreasing ranking quantity as used for cell re-selection in each frequency for at most the following number of neighbouring cells; 6 intra-frequency and 3 inter-frequency neighbours per frequency as well as 3 inter-RAT neighbours, per frequency per RAT;
3> set the IE "Logged Measurements GSM Neighbouring Cells list" in order of decreasing RXLEV.
NOTE: The UE includes, only once, the latest available results of the measurement performed for cell reselection, which are performed in accordance with the regular performance requirements as specified in [19].
2> when the memory reserved for the logging of measurements becomes full, stop timer T326 and performs the same actions as performed upon expiry of T326, as specified in 8.5.63.4.
8.6.2.3.3 Test Purpose
1. Verify logging of configured Logged MDT measurements in URA_PCH state
2. Verify logging and reporting of Logged MDT Inter-frequency measurements
3. Verify indication of availability of Logged MDT measurements in URA UPDATE message
8.6.2.3.4 Method of test
Initial Condition
System Simulator: 2 cells, Cell 1 and Cell 4 are active.
SYSTEM INFORMATION BLOCK TYPE 4 (see specific message contents).
UE: PS-DCCH+DTCH_DCH (state 6-10) in Cell 1 as specified in clause 7.4 of TS 34.108.
Test Procedure
Table 8.6.2.3-1 illustrates the downlink power to be applied for the 2 cells at various time instants of the test execution. Column marked "T0" denotes the initial conditions, while column marked "T1" is to be applied subsequently. The exact instants on which these values shall be applied are described in the texts in this clause.
Table 8.6.2.3-1
Parameter |
Unit |
Cell 1 |
Cell 4 |
||
T0 |
T1 |
T0 |
T1 |
||
UTRA RF Channel Number |
Mid Range Test Frequency |
High Range Test Frequency |
|||
CPICH Ec (FDD) |
dBm/3.84MHz |
-60 |
-69 |
-69 |
-60 |
P-CCPCH RSCP (TDD) |
dBm |
-60 |
-69 |
-69 |
-60 |
URA ID |
URA-ID 1 |
URA-ID 2 |
The UE is in CELL_DCH state of cell 1. SS transmits a LOGGING MEASUREMENT CONFIGURATION message to the UE to configure logged measurements.
SS transmits a PHYSICAL CHANNEL RECONFIGURATION message, which invokes the UE to transit from CELL_DCH to URA_PCH.
The UE transmits a PHYSICAL CHANNEL RECONFIGURATION COMPLETE message and enters URA_PCH state.
Wait 5s to allow UE to activate logging.
SS configures its downlink transmission power settings according to columns "T1" in Table 8.6.2.3-1.
When the UE detects the presence of cell 4, it moves to CELL_FACH state and transmits a URA UPDATE message on the uplink CCCH. The IE "Logged Meas Available" shall be present in the message.
Upon reception of URA_UPDATE message, SS replies with a URA UPDATE CONFIRM message with the IE "RRC State Indicator" set to "URA_PCH".
SS Pages the UE using Paging type 1 message, receives Cell-Update message from UE and SS can transmits Cell-Update message with the IE ‘RRC State Indicator” set to CELL-DCH.
SS transmits a UE INFORMATION REQUEST message, and the IE "Logged Measurements Report Request" is present.
UE shall transmits a UE INFORMATION REPONSE message, and include IE "Logged Measurement Info-FDD" or "Logged Measurement Info-TDD".
Expected Sequence
Step |
Direction |
Message |
Comment |
|
---|---|---|---|---|
UE |
SS |
|||
1 |
|
LOGGING MEASUREMENT CONFIGURATION |
The UE is in idle mode and camped onto cell 1. |
|
2 |
|
PHYSICAL CHANNEL RECONFIGURATION |
The IE "RRC state indicator" is set to "URA_PCH". |
|
3 |
|
PHYSICAL CHANNEL RECONFIGURATION COMPLETE |
The UE sends this message before it completes state transition. |
|
4 |
Wait 5s to allow UE to activate logging. |
|||
5 |
SS applies the downlink transmission power settings, according to the values in columns "T1" of table 8.6.2.3-1. The UE shall find that the Cell 4 is better and attempt to perform a cell reselection. |
|||
6 |
|
URA UPDATE |
The UE transmits this message with the IE "Logged Meas Available" set as true |
|
7 |
|
URA UPDATE CONFIRM |
IE "RRC State Indicator" is set to "URA_PCH". |
|
7a |
SS waits for 5 seconds before proceeding to next step. |
|||
7b |
|
PAGING TYPE 1 |
SS transmits Paging Type 1 message to UE. |
|
7c |
|
CELL UPDATE |
The UE transmits Cell-Update message. |
|
7d |
|
CELL UPDATE CONFIRM |
IE “RRC State Indicator” is set to Cell-DCH. |
|
7e |
|
PHYSICAL CHANNEL RECONFIGURATION COMPLETE |
||
8 |
|
UE INFORMATION REQUEST |
SS transmits a UE INFORMATION REQUEST message with IE "Logged Measurements Report Request" set to “true”. |
|
9 |
|
UE INFORMATION RESPONSE |
UE shall transmit a UE INFORMATION RESPONSE message includes IE “Logged Meas Report". |
Specific Message Contents
LOGGING MEASUREMENT CONFIGURATION (Step 1)
Information Element |
Value/remark |
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged ANR configuration Info |
|
– Absolute Time Info |
Set to value corresponding to the absolute time when the message is sent |
– Logging Duration |
10 min |
– Logging Interval |
2.56 |
– Trace reference |
|
– PLMN Identity |
Same as MIB |
– Trace ID |
‘0EF’H |
-Trace recording session |
‘1A’H |
– TCE Id |
‘5’H |
– CHOICE Area Configuration |
Not present |
PHYSICAL CHANNEL RECONFIGURATION (Steps 2)
Use the same message sub-type titled "Packet to URA_PCH from CELL_DCH in PS" in TS 34.108 clause 9.
URA UPDATE (Step 6)
The same message found in TS 34.108 clause 9 shall be transmitted by the UE on the uplink CCCH, with the exception of the following IEs:
Information Element |
Value/remark |
U-RNTI |
|
– SRNC Identity |
Check to see if set to ‘0000 0000 0001’ |
– S-RNTI |
Check to see if set to ‘0000 0000 0000 0000 0001’ |
URA Update Cause |
Check to see if set to ‘change of URA’ |
Logged Meas Available |
TRUE |
PAGING TYPE 1 (Step 7b)
Information Element |
Value/remark |
Message Type |
|
Paging record list |
Only 1 entry |
Paging record |
|
– CHOICE Used paging identity |
UTRAN identity |
– U-RNTI |
|
– SRNC Identity |
Set to the previously assigned SRNC identity |
– S-RNTI |
Set to previously assigned S-RNTI |
– CN originated page to connected mode UE |
Not Present |
BCCH modification info |
Not Present |
CELL UPDATE (Step 7c)
Check to see if the same message type found in TS 34.108, clause 9 is received, with the following exceptions:
Information Element |
Value/remark |
U-RNTI |
Checked to see if it is set to the same values as in step 7b |
– SRNC identity |
|
– S-RNTI |
|
Cell update cause |
Paging response |
CELL UPDATE CONFIRM (Step 7d)
Use the same message sub-type found in TS 34.108, clause 9 with the following exceptions:
Information Element |
Value/remark |
RRC State indicator |
CELL_DCH |
CHOICE channel requirement |
|
Uplink DPCH info |
Same as the set defined in RADIO BEARER SETUP message found in TS 34.108 clause 9 under condition A4. |
Downlink information common for all radio links |
Same as the set defined in RADIO BEARER SETUP message found in TS 34.108 clause 9 under condition A4. |
Downlink information per radio link list |
Same as the set defined in RADIO BEARER SETUP message found in TS 34.108 clause 9 under condition A4. |
UE INFORMATION REQUEST (Step 8)
Information Element |
Value/remark |
---|---|
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Measurements Report Request |
TRUE |
Logged ANR Report Request |
Not Present |
UE INFORMATION RESPONSE (FDD) (Step 9)
Information Element |
Value/remark |
---|---|
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Meas Report |
|
– Absolute Time Info |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace reference |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace recording session |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– TCE Id |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– CHOICE mode |
FDD |
– List of measurements FDD |
At least 1 entry where at least one entry complies to entry with index ‘x’ below. |
– Logged Measurement Info-FDD[x] |
|
– Relative Time Stamp[x] |
Not checked |
– Logged Measurements Serving Cell[x] |
|
– Cell ID[x] |
Cell 1 |
– Primary CCPCH RSCP[x] |
(0..91) |
– CPICH Ec/N0 |
(0..49) |
– Logged Measurements Inter Frequency Neighbouring Cells list[x] |
Only 1 inter Frequency |
– Frequency Info |
f2 |
– Logged Measurements Inter-frequency Neighbouring Cells list |
Only 1 cell |
– Primary CPICH info |
Set to the scrambling code for cell 4 |
– CPICH RSCP |
(0..91) |
– CPICH Ec/N0 |
(0..49) |
– Logged Meas Available |
Not checked |
UE INFORMATION RESPONSE (TDD) (Step 9)
Information Element |
Value/remark |
---|---|
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Meas Report |
|
– Absolute Time Info |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace reference |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace recording session |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– TCE Id |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– CHOICE mode |
TDD |
– List of measurements TDD |
At least 1 entry where at least one entry complies to entry with index ‘x’ below. |
– Logged Measurement Info-TDD[x] |
|
– Relative Time Stamp[x] |
Not checked |
– Logged Measurements Serving Cell[x] |
|
– Cell ID |
Cell 1 |
– Primary CCPCH RSCP |
(0..91) |
– Logged Measurements Inter Frequency Neighbouring Cells list[x] |
Only 1 inter Frequency |
– Frequency Info |
Frequency of Cell 4 |
– Logged Measurements Inter-frequency Neighbouring Cells list |
Only 1 cell |
– Cell parameters Id |
Cell parameter Id of Cell 4 |
– Primary CCPCH RSCP |
(0..91) |
– Logged Meas Available |
Not checked |
8.6.2.3.5 Test requirement
At step 6 the UE shall transmit a URA UPDATE message on uplink DCCH including the IE “Logged Meas Available” (TP3).
At step 9 the UE shall transmit a UE INFORMATION RESPONSE message includes IE “Logged Meas Report" with logged Measurements of Cell 4 in the “Logged Measurements Inter Frequency Neighbouring Cells list” (TP1, TP2).
8.6.2.3a Logged MDT / Intra-frequency measurement, logging and reporting / URA_PCH / PLMN list
8.6.2.3a.1 Definition
8.6.2.3a.2 Conformance requirement
[TS 25.304, clause 5.7 (TP1, TP2)]
The UE may be configured to perform logging of measurement results in idle mode, CELL_PCH and URA_PCH state with LOGGING MEASUREMENT CONFIGURATION message specified in TS 25.331 [4]. This configuration is valid while the logging duration timer is running.
If the configuration of logged measurements is valid, the UE shall perform logging of measurement results if all of the following conditions are met:
– the UE is in camped normally state in idle mode, CELL_PCH or URA_PCH state;
– the RPLMN of the UE is present in the MDT PLMN identity list, if received in the LOGGING MEASUREMENT CONFIGURATION message, or the RPLMN of the UE is the same as the RPLMN at the point of time of LOGGING MEASUREMENT CONFIGURATION message reception
– the UE is camped on a cell belonging to Area Configuration (see TS 25.331 [4]), if configured;
– the UE is camped on the RAT where the logged measurement configuration was received.
Otherwise, the logging of measurement results shall be suspended.
NOTE: Even if logging of measurement results is suspended, the logging duration timer and time stamp will continue, and the logged measurement configuration and corresponding log are kept.
[TS 25.331, clause 8.3.1.3 (TP1)]
…
In case of URA update procedure the UE shall transmit a URA UPDATE message.
…
The UE shall set the IEs in the URA UPDATE message as follows:
…
1> if an IE "Logged Measurement Info-FDD" or "Logged Measurement Info-TDD" in variable LOGGED_MEAS_REPORT_VARIABLE is present and registered PLMN is the same as the IE "PLMN Identity" stored in variable LOGGED_MEAS_REPORT_VARIABLE:
2> include IE "Logged Meas Available".
…
[TS 25.331, clause 8.5.64.3 (TP2)]
UE Shall:
1> if IE "Logged Measurements Report Request" is present:
2> if Registered PLMN is present in the IE "PLMN Identity List" stored in variable LOGGED_MEAS_REPORT_VARIABLE:
3> if an IE "Logged Measurement Info-FDD" or "Logged Measurement Info-TDD" in variable LOGGED_MEAS_REPORT_VARIABLE is present:
- set IE "Logged Meas Report" in the UE INFORMATION RESPONSE as follows:
5> include the IE "Absolute Time Info" and set it to the value of the IE "Absolute Time Info" in the variable LOGGED_MEAS_REPORT_VARIABLE;
5> include the IE "Trace reference" and set it to the value of IE "Trace reference" in the variable LOGGED_MEAS_REPORT_VARIABLE;
5> include the IE "Trace recording session" and set it to the value of the IE "Trace recording session" in the variable LOGGED_MEAS_REPORT_VARIABLE;
5> include the IE "TCE Id" and set it to the value of IE "TCE Id" in the variable LOGGED_MEAS_REPORT_VARIABLE;
5> include the IEs "Logged Measurement Info-FDD" or "Logged Measurement Info-TDD" and set it to include, in the same order as logged, one or more entries from LOGGED_MEAS_REPORT_VARIABLE;
5> clear the logged measurement results included in the list of IEs "Logged Measurement Info-FDD" or "Logged Measurement Info-TDD" from LOGGED_MEAS_REPORT_VARIABLE;
5> if the variable LOGGED_MEAS_REPORT_VARIABLE is not empty:
6> include IE "Logged Meas Available";
2> transmit a UE INFORMATION RESPONSE message on the uplink DCCH using AM RLC.
…
Reference
3GPP TS 25.304 clause 5.7 and TS 25.331 clauses 8.3.1.3, 8.5.64.3,
8.6.2.3a.3 Test Purpose
1. Verify indication of availability of Logged MDT measurements obtained in URA_PCH state at URA update procedure in the cell that belongs to the PLMN included in LOGGING MEASUREMENT CONFIGURATION message.
2. Verify that Logged Meas Report (logged in URA_PCH state) is reported in UE INFORMATION RESPONSE message.
8.6.2.3a.4 Method of test
Initial Condition
System Simulator: 2 cells, Cell 1 and Cell 2 are active.
UE: PS-DCCH+DTCH_DCH (state 6-10) in Cell 1 as specified in clause 7.4 of TS 34.108, the Attach Accept message in P2 procedure includes PLMN2 in the equivalent PLMN list.
Test Procedure
Table 8.6.2.3a-1 illustrates the downlink power to be applied for the 2 cells at various time instants of the test execution. Column marked "T0" denotes the initial conditions, while column marked "T1" is to be applied subsequently. The exact instants on which these values shall be applied are described in the texts in this clause.
Table 8.6.2.3a-1
Parameter |
Unit |
Cell 1 |
Cell 2 |
||
T0 |
T1 |
T0 |
T1 |
||
UTRA RF Channel Number |
Mid Range Test Frequency |
Mid Range Test Frequency |
|||
CPICH Ec (FDD) |
dBm/3.84MHz |
-60 |
-69 |
-69 |
-60 |
P-CCPCH RSCP (TDD) |
dBm |
-60 |
-69 |
-69 |
-60 |
URA ID |
URA-ID 1 |
URA-ID 2 |
|||
PLMN |
PLMN 1 |
PLMN 2 |
T he UE is in CELL_DCH state of cell 1. SS transmits a LOGGING MEASUREMENT CONFIGURATION message to the UE to configure logged measurements.
SS transmits a PHYSICAL CHANNEL RECONFIGURATION message, which invokes the UE to transit from CELL_DCH to URA_PCH.
The UE transmits a PHYSICAL CHANNEL RECONFIGURATION COMPLETE message and enters URA_PCH state.
Wait 5s to allow UE to activate logging.
SS configures its downlink transmission power settings according to columns "T1" in Table 8.6.2.3a-1.
When the UE detects the presence of cell 2, it moves to CELL_FACH state and transmits a URA UPDATE message on the uplink CCCH. The IE "Logged Meas Available" shall be present in the message.
Upon reception of URA_UPDATE message, SS replies with a URA UPDATE CONFIRM message with the IE "RRC State Indicator" set to "CELL_DCH".
Completes ROUTING AREA UPDATE procedure.
SS transmits a UE INFORMATION REQUEST message, and the IE "Logged Measurements Report Request" is present.
UE shall transmits a UE INFORMATION REPONSE message, and include IE "Logged Measurement Info-FDD" or "Logged Measurement Info-TDD".
Expected Sequence
Step |
Direction |
Message |
Comment |
|
---|---|---|---|---|
UE |
SS |
|||
1 |
|
LOGGING MEASUREMENT CONFIGURATION |
||
1a |
SS waits for 200msec to ensure UE acts upon Step 1 before proceeding to next step. |
|||
2 |
|
PHYSICAL CHANNEL RECONFIGURATION |
The IE "RRC state indicator" is set to "URA_PCH". |
|
3 |
|
PHYSICAL CHANNEL RECONFIGURATION COMPLETE |
The UE sends this message before it completes state transition. |
|
4 |
– |
– |
Wait 5s to allow UE to activate logging. |
|
5 |
– |
– |
SS applies the downlink transmission power settings, according to the values in columns "T1" of table 8.6.2.3a-1. The UE shall find that the Cell 2 is better and attempt to perform a cell reselection. |
|
6 |
|
URA UPDATE |
The UE transmits this message with the IE "Logged Meas Available" set as true |
|
7 |
|
URA UPDATE CONFIRM |
IE "RRC State Indicator" is set to "CELL_DCH". |
|
8 |
–> |
RRC: INITIAL DIRECT TRANSFER NAS: ROUTING AREA UPDATE REQUEST |
The UE transmits a ROUTING AREA UPDATE REQUEST message. |
|
9 |
<– |
RRC: DOWNLINK DIRECT TRANSFER NAS: ROUTING AREA UPDATE ACCEPT |
The SS transmits a ROUTING AREA UPDATE ACCEPT message. |
|
10 |
–> |
RRC: UPLINK DIRECT TRANSFER NAS: ROUTING AREA UPDATE COMPLETE |
The UE transmits a ROUTING AREA UPDATE COMPLETE message. |
|
11 |
|
UE INFORMATION REQUEST |
SS transmits a UE INFORMATION REQUEST message with IE "Logged Measurements Report Request" set to “true”. |
|
12 |
|
UE INFORMATION RESPONSE |
UE shall transmit a UE INFORMATION RESPONSE message includes IE “Logged Meas Report". |
Specific Message Contents
SYSTEM INFORMATION BLOCK TYPE 4
Use the same message type found in clause 6.1.0b of TS 34.108, with the following exceptions for Cell 1:
– Qqualmin |
-16 |
LOGGING MEASUREMENT CONFIGURATION (Step 1)
Information Element |
Value/remark |
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged ANR configuration Info |
|
– Absolute Time Info |
Set to value corresponding to the absolute time when the message is sent |
– Logging Duration |
10 min |
– Logging Interval |
|
– Trace reference |
|
– PLMN Identity |
Same as MIB |
– Trace ID |
‘0EF’H |
-Trace recording session |
‘1A’H |
– TCE Id |
‘5’H |
– CHOICE Area Configuration |
Not present |
– PLMN Identity List |
|
– PLMN Identity |
PLMN2 |
PHYSICAL CHANNEL RECONFIGURATION (Steps 2)
Use the same message sub-type titled "Packet to URA_PCH from CELL_DCH in PS" in TS 34.108 clause 9.
URA UPDATE (Step 6)
The same message found in TS 34.108 clause 9 shall be transmitted by the UE on the uplink CCCH, with the exception of the following IEs:
Information Element |
Value/remark |
U-RNTI |
|
– SRNC Identity |
Check to see if set to ‘0000 0000 0001’ |
– S-RNTI |
Check to see if set to ‘0000 0000 0000 0000 0001’ |
URA Update Cause |
Check to see if set to ‘change of URA’ |
Logged Meas Available |
TRUE |
UE INFORMATION REQUEST (Step 11)
Information Element |
Value/remark |
---|---|
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Measurements Report Request |
TRUE |
Logged ANR Report Request |
Not Present |
UE INFORMATION RESPONSE (FDD) (Step 12)
Information Element |
Value/remark |
---|---|
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Meas Report |
|
– Absolute Time Info |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace reference |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace recording session |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– TCE Id |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– CHOICE mode |
FDD |
– List of measurements FDD |
At least 1 entry where at least one entry complies to entry with index ‘x’ below. |
– Logged Measurement Info-FDD[x] |
|
– Relative Time Stamp[x] |
Not checked |
– Logged Measurements Serving Cell[x] |
|
– PLMN Identity |
PLMN 1 |
– Cell ID[x] |
Cell 1 |
– Primary CCPCH RSCP[x] |
(0..91) |
– CPICH Ec/N0 |
(0..49) |
– Logged Measurements Intra Frequency list[x] |
Only 1 intra Frequency cell |
– Primary CPICH info |
Set to the scrambling code for cell 2 |
– CPICH RSCP |
(0..91) |
– CPICH Ec/N0 |
(0..49) |
– Logged Meas Available |
Not checked |
UE INFORMATION RESPONSE (TDD) (Step 12)
Information Element |
Value/remark |
---|---|
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Meas Report |
|
– Absolute Time Info |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace reference |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace recording session |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– TCE Id |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– CHOICE mode |
TDD |
– List of measurements TDD |
At least 1 entry where at least one entry complies to entry with index ‘x’ below. |
– Logged Measurement Info-TDD[x] |
|
– Relative Time Stamp[x] |
Not checked |
– Logged Measurements Serving Cell[x] |
|
– PLMN Identity |
PLMN 1 |
– Cell ID |
Cell 1 |
– Primary CCPCH RSCP |
(0..91) |
– Logged Measurements Intra Frequency list[x] |
Only 1 intra Frequency cell |
– Cell parameters Id |
Cell parameter Id of Cell 2 |
– Primary CCPCH RSCP |
(0..91) |
– Logged Meas Available |
Not checked |
8.6.2.3a.5 Test requirement
At step 6 the UE shall transmit a URA UPDATE message on uplink DCCH including the IE “Logged Meas Available” (TP1).
At step 12 the UE shall transmit a UE INFORMATION RESPONSE message includes IE “Logged Meas Report" with logged Measurements of Cell 2 in the “Logged Measurements Intra Frequency Neighbouring Cells list” (TP2).
8.6.2.4 Logged MDT / Intra-frequency measurement, logging and reporting / Idle mode / Limiting area scope
8.6.2.4.1 Definition
This test is applicable for all UEs that support Logged MDT services.
8.6.2.4.2 Conformance requirement
[TS 25.304, clause 5.7 (TP1, TP2, TP3)]
The UE may be configured to perform logging of measurement results in idle mode, CELL_PCH and URA_PCH state with LOGGING MEASUREMENT CONFIGURATION message specified in TS 25.331 [4]. This configuration is valid while the logging duration timer is running.
If the configuration of logged measurements is valid, the UE shall perform logging of measurement results if all of the following conditions are met:
– the UE is in camped normally state in idle mode, CELL_PCH or URA_PCH state;
– RPLMN of the UE is the same as the RPLMN at the point of time of LOGGING MEASUREMENT CONFIGURATION message reception
– the UE is camped on a cell belonging to Area Configuration (see TS 25.331 [4]), if configured;
– the UE is camped on the RAT where the logged measurement configuration was received.
Otherwise, the logging of measurement results shall be suspended.
NOTE: Even if logging of measurement results is suspended, the logging duration timer and time stamp will continue, and the logged measurement configuration and corresponding log are kept.
[TS 25.331, clause 8.5.65.2 (TP1, TP2, TP3)]
While T326 is running, the UE shall:
1> perform this logging in accordance with the following:
2> perform the logging while camping normally on an UTRA cell and the RPLMN of the UE is the same as the PLMN Identity stored in LOGGED_MEAS_REPORT_VARIABLE and, if the IE "Area Configuration" is present in variable LOGGED_MEAS_CONFIG, that is part of the concerned area;
2> perform the logging at regular intervals, as defined by the IE "Logging Interval" in variable LOGGED_MEAS_CONFIG;
2> when adding a logged measurement entry in variable LOGGED_MEAS_REPORT_VARIABLE, include the fields in accordance with the following:
3> set the IE "Relative Time Stamp" to indicate time relative to the moment at which the logged measurement configuration was received;
3> if GNSS location information became available during the last logging interval:
4> if the UE has been able to calculate a 3-dimensional position:
5> set IE "Ellipsoid point with altitude" to include the location coordinates;
4>else:
5> set IE "Ellipsoid point" to include the location coordinates:
3> set the IE "Cell ID" to indicate cell identity of the cell the UE is camping on obtained from system information;
3> set the IE "CPICH Ec/N0" and "CPICH RSCP" to include measured quantities of the cell that the UE is camping on for UTRA FDD;
3> set the "P-CCPCH RSCP" to include measured quantities for the cell that the UE is camping on for UTRA 1.28 Mcps TDD;
3> set the IE "Logged Measurements Intra Frequency Neighbouring Cells list", "Logged Measurements Inter Frequency list", "Logged Measurements E-UTRA frequency list", in order of decreasing ranking quantity as used for cell re-selection in each frequency for at most the following number of neighbouring cells; 6 intra-frequency and 3 inter-frequency neighbours per frequency as well as 3 inter-RAT neighbours, per frequency per RAT;
3> set the IE "Logged Measurements GSM Neighbouring Cells list" in order of decreasing RXLEV.
NOTE: The UE includes, only once, the latest available results of the measurement performed for cell reselection, which are performed in accordance with the regular performance requirements as specified in [19].
2> when the memory reserved for the logging of measurements becomes full, stop timer T326 and performs the same actions as performed upon expiry of T326, as specified in 8.5.63.4.
Reference
TS 25.304 clause 5.7 and TS 25.331 clause 8.5.65.2
.8.6.2.4.3 Test Purpose
1. Verify limiting area scope logging of configured Logged MDT measurements when area scope based on cell list is configured
2. Verify limiting area scope logging of configured Logging MDT measurements when area scope based on list of Location Areas is configured
3. Verify limiting area scope logging of configured Logging MDT measurements when area scope based on list of Routing Areas is configured.
8.6.2.4.4 Method of test
Initial conditions
System Simulator:
3 cells, cell 1, cell 2 and cell 3.
User Equipment:
UE: PS-DCCH+DTCH_DCH (state 6-10) in Cell 1 as specified in clause 7.4 of TS 34.108.
Test procedure
Table 8.6.2.4.4-1 illustrates the downlink power to be applied for the 3 cells. Column marked "T0" denotes the initial conditions, while columns marked "T1", "T2", “T3”,"T4", “T5” and “T6” are to be applied subsequently. The exact instants on which these values shall be applied are described in the text in this clause.
Parameter |
Unit |
Cell 1 |
Cell 2 |
Cell 3 |
||||||||||||||||||
T0 |
T1 |
T2 |
T3 |
T4 |
T5 |
T6 |
T0 |
T1 |
T2 |
T3 |
T4 |
T5 |
T6 |
T0 |
T1 |
T2 |
T3 |
T4 |
T5 |
T6 |
||
UTRA RF Channel Number |
Mid Range Test Frequency |
Mid Range Test Frequency |
Mid Range Test Frequency |
|||||||||||||||||||
LAC |
1 |
2 |
1 |
|||||||||||||||||||
RAC |
1 |
2 |
2 |
|||||||||||||||||||
CPICH Ec (FDD) |
dBm/3.84 MHz |
-60 |
OFF |
OFF |
-60 |
OFF |
OFF |
-60 |
OFF |
-60 |
OFF |
OFF |
-60 |
OFF |
OFF |
OFF |
OFF |
-60 |
OFF |
OFF |
-60 |
OFF |
P-CCPCH RSCP(TDD) |
dBm |
-60 |
OFF |
OFF |
-60 |
OFF |
OFF |
-60 |
OFF |
-60 |
OFF |
OFF |
-60 |
OFF |
OFF |
OFF |
OFF |
-60 |
OFF |
OFF |
-60 |
OFF |
a) SS transmits a LOGGING MEASUREMENT CONFIGURATION message with a cell list on Cell 1 and only Cell 3 in the configured cell list. SS changes Cell 1, Cell 2 and Cell 3 level, and the UE moves to idle mode on Cell 2.Verify Logging MDT measurements on Cell 2.
b) SS changes Cell 1, Cell 2 and Cell 3 level, and the UE moves to idle mode on Cell 3. Verify Logging MDT measurements on Cell 3.
c) Re-configure logged measurement with limiting area scope using Location Areas list, only Cell 2 belongs to Location Areas in the list. SS changes Cell 1, Cell 2 and Cell 3 level, and the UE moves to idle mode on Cell 1. Verify Logging MDT measurements on Cell 1.
d) SS changes Cell 1, Cell 2 and Cell 3 level, and the UE moves to idle mode on Cell 2. Verify Logging MDT measurements on Cell 2.
e) Re-configure logged measurement with limiting area scope using Routing Areas list and only Cell 1 belongs to Routing Areas in configured Routing Areas list. SS changes Cell 1, Cell 2 and Cell 3 level, and the UE moves to idle mode on Cell 3. Verify Logging MDT measurements on Cell 3.
f) SS changes Cell 1, Cell 2 and Cell 3 level, and the UE moves to idle mode on Cell 1. Verify Logging MDT measurements on Cell 1.
Expected sequence
Step |
Direction |
Message |
Comments |
|
---|---|---|---|---|
UE |
SS |
|||
1 |
<– |
LOGGING MEASUREMENT CONFIGURATION |
SS transmits a LOGGING MEASUREMENT CONFIGURATION message with a cell list on Cell 1. Only Cell 3 in configured cell list. |
|
2 |
<– |
RRC CONNECTION RELEASE |
SS transmits a RRC CONNECTION RELEASE message to release the RRC connection. |
|
3 |
–> |
RRC CONNECTION RELEASE COMPLETE |
UE confirms the connection release and returns to Idle mode. |
|
4 |
– |
SS changes Cell 1, Cell 2 and Cell 3 level according to the T1 in Table 8.6.2.4.4-1. Call generic procedure in 36.508 subclause 6.4.2.8-1, UE reselects to cell 2. The UE performs a RAU procedure and the RRC Connection is released. |
||
5 |
– |
– |
Wait 10 seconds for UE logging interval timer to expire at least once |
|
6 |
<– |
Paging |
SS transmits a Paging message. |
|
7 |
–> |
RRC CONNECTION REQUEST |
The UE transmits an RRC CONNECTION REQUEST message. |
|
8 |
<– |
RRC CONNECTION SETUP |
SS transmit an RRC CONNECTION SETUP message. |
|
9 |
–> |
RRC CONNECTION SETUP COMPLETE |
The UE shall transmit an RRC CONNECTION SETUP COMPLETE message with IE “Logged Meas Available” not present. |
|
10 |
–> |
RRC: INITIAL DIRECT TRANSFER NAS: SERVICE REQUEST |
The UE transmits SERVICE REQUEST message. |
|
11 |
<– |
RRC CONNECTION RELEASE |
SS transmits a RRC CONNECTION RELEASE message to release the RRC connection. |
|
12 |
–> |
RRC CONNECTION RELEASE COMPLETE |
The UE confirms the connection release and returns to Idle mode. |
|
13 |
– |
– |
SS changes Cell 1, Cell 2 and Cell 3 level according to the T2 in Table 8.6.2.4.4-1. Call generic procedure in 36.508 subclause 6.4.2.8-1, UE reselects to cell 3. The UE performs a RAU procedure and the RRC Connection is released. |
|
14 |
Wait 10 seconds for UE logging interval timer to expire at least once |
|||
15 |
<– |
Paging |
SS transmits a Paging message. |
|
16 |
–> |
RRC CONNECTION REQUEST |
The UE transmits an RRC CONNECTION REQUEST message. |
|
17 |
<– |
RRC CONNECTION SETUP |
SS transmit an RRC CONNECTION SETUP message. |
|
18 |
–> |
RRC CONNECTION SETUP COMPLETE |
The UE shall transmit an RRC CONNECTION SETUP COMPLETE message including IE “Logged Meas Available”. |
|
19 |
–> |
RRC: INITIAL DIRECT TRANSFER NAS: SERVICE REQUEST |
The UE transmits SERVICE REQUEST message. |
|
20 |
<– |
UE INFORMATION REQUEST |
SS send an UE INFORMATION REQUEST message to get logMeasReport. |
|
21 |
–> |
UE INFORMATION RESPONSE |
The UE shall send an UE INFORMATION RESPONSE message with Logged Meas Report of Cell 3. |
|
22 |
<– |
LOGGING MEASUREMENT CONFIGURATION |
SS transmits a LOGGING MEASUREMENT CONFIGURATION message with a using Location Areas list on Cell 3, only Cell 2 belongs to Location Areas in the list. |
|
23 |
<– |
RRC CONNECTION RELEASE |
SS transmits a RRC CONNECTION RELEASE message to release RRC connection and moves to idle mode on Cell 3. |
|
24 |
–> |
RRC CONNECTION RELEASE COMPLETE |
UE confirms the connection release and returns to Idle mode |
|
25 |
– |
– |
SS changes Cell 1, Cell 2 and Cell 3 level according to the T3 in Table 8.6.2.4.4-1. Call generic procedure in 36.508 subclause 6.4.2.8-1, UE reselects to cell 1. The UE performs a RAU procedure and the RRC Connection is released. |
|
26 |
Wait 10 seconds for UE logging interval timer to expire at least once |
|||
27 |
<– |
Paging |
SS transmits a Paging message. |
|
28 |
–> |
RRC CONNECTION REQUEST |
The UE transmits an RRC CONNECTION REQUEST message. |
|
29 |
<– |
RRC CONNECTION SETUP |
SS transmit an RRC CONNECTION SETUP message. |
|
30 |
–> |
RRC CONNECTION SETUP COMPLETE |
The UE shall transmit an RRC CONNECTION SETUP COMPLETE message with IE “Logged Meas Available” not present. |
|
31 |
–> |
RRC: INITIAL DIRECT TRANSFER NAS: SERVICE REQUEST |
The UE transmits SERVICE REQUEST message. |
|
32 |
<– |
RRC CONNECTION RELEASE |
SS transmits a RRC CONNECTION RELEASE message to release the RRC connection. |
|
33 |
–> |
RRC CONNECTION RELEASE COMPLETE |
The UE confirms the connection release and returns to Idle mode. |
|
34 |
– |
– |
SS changes power level of Cell 1, Cell 2, and Cell 3 according to the T4 in Table 8.6.2.4.4-1. Call generic procedure in 36.508 subclause 6.4.2.8-1, UE reselects to cell 2. The UE performs a RAU procedure and the RRC Connection is released. |
|
35 |
Wait 10 seconds for UE logging interval timer to expire at least once. |
|||
36 |
<– |
Paging |
SS transmits a Paging message on Cell 2. |
|
37 |
–> |
RRC CONNECTION REQUEST |
The UE transmits an RRC CONNECTION REQUEST message on Cell 2. |
|
38 |
<– |
RRC CONNECTION SETUP |
SS transmit an RRC CONNECTION SETUP message on Cell 2. |
|
39 |
–> |
RRC CONNECTION SETUP COMPLETE |
The UE shall transmit an RRC CONNECTION SETUP COMPLETE message including IE “Logged Meas Available”. |
|
40 |
–> |
RRC: INITIAL DIRECT TRANSFER NAS: SERVICE REQUEST |
The UE transmits SERVICE REQUEST message. |
|
41 |
<– |
UE INFORMATION REQUEST |
SS send a UE INFORMATION REQUEST message to get logMeasReport. |
|
42 |
–> |
UE INFORMATION RESPONSE |
The UE shall send an UE INFORMATION RESPONSE message with Logged Meas Report of Cell 2. |
|
43 |
<– |
LOGGING MEASUREMENT CONFIGURATION |
SS transmits a LOGGING MEASUREMENT CONFIGURATION message with a Routing Areas List on Cell 2. Only Cell 1 belongs to Routing Areas in configured Routing Areas list. |
|
44 |
<– |
RRC CONNECTION RELEASE |
SS transmits a RRC CONNECTION RELEASE message to release RRC connection and moves to idle mode on Cell 2. |
|
45 |
–> |
RRC CONNECTION RELEASE COMPLETE |
UE confirms the connection release and returns to Idle mode. |
|
46 |
– |
– |
SS changes Cell 1, Cell 2 and Cell 3 level according to the T5 in Table 8.6.2.4.4-1. Call generic procedure in 36.508 subclause 6.4.2.8-1, UE reselects to cell 3. The UE performs a RAU procedure and the RRC Connection is released. |
|
47 |
– |
Wait 10 seconds for UE logging interval timer to expire at least once |
||
48 |
<– |
Paging |
SS transmits a Paging message. |
|
49 |
–> |
RRC CONNECTION REQUEST |
The UE transmits an RRC CONNECTION REQUEST message. |
|
50 |
<– |
RRC CONNECTION SETUP |
SS transmit an RRC CONNECTION SETUP message. |
|
51 |
–> |
RRC CONNECTION SETUP COMPLETE |
The UE shall transmit an RRC CONNECTION SETUP COMPLETE message and IE “Logged Meas Available” is not present. |
|
52 |
–> |
RRC: INITIAL DIRECT TRANSFER NAS: SERVICE REQUEST |
The UE transmits SERVICE REQUEST message. |
|
53 |
<– |
RRC CONNECTION RELEASE |
SS transmits an RRC CONNECTION RELEASE message to release the RRC connection. |
|
54 |
–> |
RRC CONNECTION RELEASE COMPLETE |
UE confirms the connection release and returns to Idle mode. |
|
55 |
– |
– |
SS changes Cell 1, Cell 2 and Cell 3 level according to the T6 in Table 8.6.2.4.4-1. Call generic procedure in 36.508 subclause 6.4.2.8-1, UE reselects to cell 1. The UE performs a RAU procedure and the RRC Connection is released. |
|
56 |
– |
– |
Wait 10 seconds for UE logging interval timer to expire at least once |
|
57 |
<– |
Paging |
SS transmits a Paging message on Cell 1. |
|
58 |
–> |
RRC CONNECTION REQUEST |
The UE transmits an RRC CONNECTION REQUEST message on Cell1. |
|
59 |
<– |
RRC CONNECTION SETUP |
SS transmit an RRC CONNECTION SETUP message on Cell 1. |
|
60 |
–> |
RRC CONNECTION SETUP COMPLETE |
The UE shall transmit an RRC CONNECTION SETUP COMPLETE message including IE Logged Meas Available. |
|
61 |
–> |
RRC: INITIAL DIRECT TRANSFER NAS: SERVICE REQUEST |
The UE transmits SERVICE REQUEST message. |
|
62 |
<– |
UE INFORMATION REQUEST |
SS send a UE INFORMATION REQUEST message to get logMeasReport. |
|
63 |
–> |
UE INFORMATION RESPONSE |
The UE shall send an UE INFORMATION RESPONSE message with Logged Meas Report of Cell 1? |
|
64 |
<– |
RRC CONNECTION RELEASE |
SS transmits an RRC CONNECTION RELEASE message to release the RRC connection. |
|
65 |
–> |
RRC CONNECTION RELEASE COMPLETE |
UE confirms the connection release and returns to Idle mode. |
Specific message contents
All messages have the same content as defined in 34.108 clause 9 with the following exceptions:
LOGGING MEASUREMENT CONFIGURATION (Step 1)
Information Element |
Value/remark |
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Measurements Configuration Info |
|
– Absolute Time Info |
Set to value corresponding to the absolute time when the message is sent |
– Logging Duration |
10 min |
– Logging Interval |
2.59 |
– Trace reference |
|
– PLMN Identity |
Same as MIB |
– Trace ID |
‘0EF’H |
-Trace recording session |
‘1A’H |
– TCE Id |
‘5’H |
– CHOICE Area Configuration |
|
– Cell IDList |
|
– Cell ID |
Cell 3 |
RRC CONNECTION SETUP COMPLETE (step 9)
Information Element |
Value/remark |
Message Type |
|
RRC transaction identifier |
The value of this IE is checked to see that it matches the value of the same IE transmitted in the downlink RRC CONNECTION SETUP message. |
Logged Meas Available |
Not present |
RRC CONNECTION SETUP COMPLETE (step 18)
Information Element |
Value/remark |
Message Type |
|
RRC transaction identifier |
The value of this IE is checked to see that it matches the value of the same IE transmitted in the downlink RRC CONNECTION SETUP message. |
Logged Meas Available |
True |
UE INFORMATION RESPONSE (FDD) (Step 21)
Information Element |
Value/remark |
---|---|
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Meas Report |
|
– Absolute Time Info |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace reference |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– PLMN Identity |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace ID |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace recording session |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– TCE Id |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– CHOICE mode |
FDD |
– List of measurements FDD |
At least 1 entry where at least one entry complies to entry with index ‘x’ below. |
– Logged Measurement Info-FDD[x] |
|
– Relative Time Stamp[x] |
Not checked |
– Logged Measurements Serving Cell[x] |
|
– Cell ID[x] |
Cell 3 |
– Primary CCPCH RSCP[x] |
(0..91) |
– CPICH Ec/N0 |
(0..49) |
– Logged Meas Available |
Not checked |
UE INFORMATION RESPONSE (TDD) (Step 21)
Information Element |
Value/remark |
---|---|
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Meas Report |
|
– Absolute Time Info |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace reference |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace recording session |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– PLMN Identity |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace ID |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– TCE Id |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– CHOICE mode |
TDD |
– List of measurements TDD |
At least 1 entry where at least one entry complies to entry with index ‘x’ below. |
– Logged Measurement Info-TDD[x] |
|
– Relative Time Stamp[x] |
Not checked |
– Logged Measurements Serving Cell[x] |
|
– Cell ID |
Cell 3 |
– Primary CCPCH RSCP |
(0..91) |
– Logged Meas Available |
Not checked |
LOGGING MEASUREMENT CONFIGURATION (Step 22)
Information Element |
Value/remark |
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged ANR configuration Info |
|
– Absolute Time Info |
Set to value corresponding to the absolute time when the message is sent |
– Logging Duration |
10 min |
– Logging Interval |
|
– Trace reference |
|
– PLMN Identity |
Same as MIB |
– Trace ID |
‘0EF’H |
-Trace recording session |
‘1A’H |
– TCE Id |
‘5’H |
– CHOICE Area Configuration |
|
– Location Area Code List |
|
– LAI |
|
– PLMN identity |
Same as MIB |
– LAC |
2 |
RRC CONNECTION SETUP COMPLETE (step 30)
Information Element |
Value/remark |
Message Type |
|
RRC transaction identifier |
The value of this IE is checked to see that it matches the value of the same IE transmitted in the downlink RRC CONNECTION SETUP message. |
Logged Meas Available |
Not present |
RRC CONNECTION SETUP COMPLETE (step 39)
Information Element |
Value/remark |
Message Type |
|
RRC transaction identifier |
The value of this IE is checked to see that it matches the value of the same IE transmitted in the downlink RRC CONNECTION SETUP message. |
Logged Meas Available |
True |
UE INFORMATION RESPONSE (FDD) (Step 42)
Information Element |
Value/remark |
---|---|
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Meas Report |
|
– Absolute Time Info |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace reference |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– PLMN Identity |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace ID |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace recording session |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– TCE Id |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– CHOICE mode |
FDD |
– List of measurements FDD |
At least 1 entry where at least one entry complies to entry with index ‘x’ below. |
– Logged Measurement Info-FDD[x] |
|
– Relative Time Stamp[x] |
Not checked |
– Logged Measurements Serving Cell[x] |
|
– Cell ID[x] |
Cell 2 |
– Primary CCPCH RSCP[x] |
(0..91) |
– CPICH Ec/N0 |
(0..49) |
– Logged Meas Available |
Not checked |
UE INFORMATION RESPONSE (TDD) (Step 42)
Information Element |
Value/remark |
---|---|
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Meas Report |
|
– Absolute Time Info |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace reference |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– PLMN Identity |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace ID |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace recording session |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– TCE Id |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– CHOICE mode |
TDD |
– List of measurements TDD |
At least 1 entry where at least one entry complies to entry with index ‘x’ below. |
– Logged Measurement Info-TDD[x] |
|
– Relative Time Stamp[x] |
Not checked |
– Logged Measurements Serving Cell[x] |
|
– Cell ID |
Cell 2 |
– Primary CCPCH RSCP |
(0..91) |
– Logged Meas Available |
Not checked |
LOGGING MEASUREMENT CONFIGURATION (Step 43)
Information Element |
Value/remark |
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Measurements Configuration Info |
|
– Absolute Time Info |
Set to value corresponding to the absolute time when the message is sent |
– Logging Duration |
10 min |
– Logging Interval |
2.56 |
– Trace reference |
|
– PLMN Identity |
Same as MIB |
– Trace ID |
‘0EF’H |
-Trace recording session |
‘1A’H |
– TCE Id |
‘5’H |
– CHOICE Area Configuration |
|
– Routing Code Area List |
|
– RAI |
|
– LAI |
PLMN identity set to Same as MIB, and LAC=1 |
– RAC |
1 |
RRC CONNECTION SETUP COMPLETE (step 51)
Information Element |
Value/remark |
Message Type |
|
RRC transaction identifier |
The value of this IE is checked to see that it matches the value of the same IE transmitted in the downlink RRC CONNECTION SETUP message. |
Logged Meas Available |
Not present |
RRC CONNECTION SETUP COMPLETE (step 60)
Information Element |
Value/remark |
Message Type |
|
RRC transaction identifier |
The value of this IE is checked to see that it matches the value of the same IE transmitted in the downlink RRC CONNECTION SETUP message. |
Logged Meas Available |
True |
UE INFORMATION RESPONSE (FDD) (Step 63)
Information Element |
Value/remark |
---|---|
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Meas Report |
|
– Absolute Time Info |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 29 |
– Trace reference |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 29 |
– PLMN Identity |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 29 |
– Trace ID |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 29 |
– Trace recording session |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 29 |
– TCE Id |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 29 |
– CHOICE mode |
FDD |
– List of measurements FDD |
At least 1 entry where at least one entry complies to entry with index ‘x’ below. |
– Logged Measurement Info-FDD[x] |
|
– Relative Time Stamp[x] |
Not checked |
– Logged Measurements Serving Cell[x] |
|
– Cell ID[x] |
Cell 1 |
– Primary CCPCH RSCP[x] |
(0..91) |
– CPICH Ec/N0 |
(0..49) |
– Logged Meas Available |
Not checked |
UE INFORMATION RESPONSE (TDD) (Step 63)
Information Element |
Value/remark |
---|---|
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Meas Report |
|
– Absolute Time Info |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 29 |
– Trace reference |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 29 |
– PLMN Identity |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 29 |
– Trace ID |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 29 |
– Trace recording session |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 29 |
– TCE Id |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 29 |
– CHOICE mode |
TDD |
– List of measurements TDD |
At least 1 entry where at least one entry complies to entry with index ‘x’ below. |
– Logged Measurement Info-TDD[x] |
|
– Relative Time Stamp[x] |
Not checked |
– Logged Measurements Serving Cell[x] |
|
– Cell ID |
Cell 1 |
– Primary CCPCH RSCP |
(0..91) |
– Logged Meas Available |
Not checked |
8.6.2.4.5 Test requirements
At step 9, the UE shall transmit an RRC CONNECTION SETUP COMPLETE message with IE “Logged Meas Available” not present (TP1).
At step 18, the UE shall transmit an RRC CONNECTION SETUP COMPLETE message including IE “Logged Meas Available” (TP1).
At step 21, the UE shall send an UE INFORMATION RESPONSE message with Logged Meas Report of Cell 3(TP1).
At step 30, the UE shall transmit an RRC CONNECTION SETUP COMPLETE message with IE “Logged Meas Available” not present (TP2).
At step 39, the UE shall transmit an RRC CONNECTION SETUP COMPLETE message including IE “Logged Meas Available” (TP2).
At step 42, the UE shall send an UE INFORMATION RESPONSE message with Logged Meas Report of Cell 2 (TP2).
At step 51, the UE shall transmit an RRC CONNECTION SETUP COMPLETE message with IE “Logged Meas Available” not present (TP3).
At step 60 the UE shall transmit an RRC CONNECTION SETUP COMPLETE message including IE “Logged Meas Available” (TP3).
At step 63 the UE shall send an UE INFORMATION RESPONSE message with Logged Meas Report of Cell 1(TP3).
8.6.2.4a Logged MDT / Intra-frequency measurement, logging and reporting / Idle mode / Limiting area scope / Cell ID list with PLMN identity
8.6.2.4a.1 Definition
This test is applicable for all UEs that support Logged MDT services.
8.6.2.4a.2 Conformance requirement
[TS 25.304, clause 5.7 (TP1, TP2)]
The UE may be configured to perform logging of measurement results in idle mode, CELL_PCH and URA_PCH state with LOGGING MEASUREMENT CONFIGURATION message specified in TS 25.331 [4]. This configuration is valid while the logging duration timer is running.
If the configuration of logged measurements is valid, the UE shall perform logging of measurement results if all of the following conditions are met:
– the UE is in camped normally state in idle mode, CELL_PCH or URA_PCH state;
– the RPLMN of the UE is present in the MDT PLMN identity list, if received in the LOGGING MEASUREMENT CONFIGURATION message, or the RPLMN of the UE is the same as the RPLMN at the point of time of LOGGING MEASUREMENT CONFIGURATION message reception
– the UE is camped on a cell belonging to Area Configuration (see TS 25.331 [4]), if configured;
– the UE is camped on the RAT where the logged measurement configuration was received.
Otherwise, the logging of measurement results shall be suspended.
NOTE: Even if logging of measurement results is suspended, the logging duration timer and time stamp will continue, and the logged measurement configuration and corresponding log are kept.
[TS 25.331, clause 8.5.65.2 (TP1, TP2)]
While T326 is running, the UE shall:
1> perform this logging in accordance with the following:
2> perform the logging while camping normally on an UTRA cell and the RPLMN of the UE is present in the "PLMN Identity List" stored in LOGGED_MEAS_REPORT_VARIABLE and, if the IE "Area Configuration" is present in variable LOGGED_MEAS_CONFIG, that is part of the concerned area;
2> perform the logging at regular intervals, as defined by the IE "Logging Interval” in variable LOGGED_MEAS_CONFIG;
2> when adding a logged measurement entry in variable LOGGED_MEAS_REPORT_VARIABLE, include the fields in accordance with the following:
3> set the IE "Relative Time Stamp" to indicate time relative to the moment at which the logged measurement configuration was received;
3> if GNSS location information became available during the last logging interval:
4> if the UE has been able to calculate a 3-dimensional position:
5> set IE "Ellipsoid point with altitude" or the IE "Ellipsoid point with altitude and uncertainty ellipsoid" to include the location coordinates;
4>else:
5> set IE "Ellipsoid point" or the IE "Ellipsoid point with uncertainty circle" or the IE "Ellipsoid point with uncertainty ellipse" to include the location coordinates:
4> a value of the IE "Confidence", different from "0" should be calculated, as the probability that the UE is located within the uncertainty region of the one of the IEs "Ellipsoid point with uncertainty ellipse" or "Ellipsoid point with altitude and uncertainty ellipsoid".
3> set the IE "PLMN Identity" of the Logged Measurements Serving Cell to indicate the PLMN Identity of the cell the UE is camping on obtained from system information;
3> set the IE "Cell ID" to indicate cell identity of the cell the UE is camping on obtained from system information;
3> set the IE "CPICH Ec/N0" and "CPICH RSCP" to include measured quantities of the cell that the UE is camping on for UTRA FDD;
3> set the "P-CCPCH RSCP" to include measured quantities for the cell that the UE is camping on for UTRA 1.28 Mcps TDD;
3> set the IE "Logged Measurements Intra Frequency Neighbouring Cells list", "Logged Measurements Inter Frequency list", "Logged Measurements E-UTRA frequency list", "Logged Measurements E-UTRA frequency extension list", in order of decreasing ranking quantity as used for cell re-selection in each frequency for at most the following number of neighbouring cells; 6 intra-frequency and 3 inter-frequency neighbours per frequency as well as 3 inter-RAT neighbours, per frequency per RAT;
3> set the IE "Logged Measurements GSM Neighbouring Cells list" in order of decreasing RXLEV.
NOTE: The UE includes, only once, the latest available results of the measurement performed for cell reselection, which are performed in accordance with the regular performance requirements as specified in [19].
2> when the memory reserved for the logging of measurements becomes full, stop timer T326 and performs the same actions as performed upon expiry of T326, as specified in 8.5.63.4.
Reference
TS 25.304 clause 5.7 and TS 25.331 clause 8.5.65.2
.8.6.2.4a.3 Test Purpose
1. Verify UE is logging when area scope based on Cell ID list with PLMN identity is configured and UE is camping on a cell in the Cell ID list with PLMN identity.
2. Verify UE is not logging of configured Logging MDT measurements when area scope based on Cell ID list with PLMN identity is configured and UE is camping on a cell not included in the Cell ID list with PLMN identity
8.6.2.4a.4 Method of test
Initial conditions
System Simulator:
3 cells, cell 1, cell 2 and cell 3.
User Equipment:
UE: PS-DCCH+DTCH_DCH (state 6-10) in Cell 1 as specified in clause 7.4 of TS 34.108, the Attach Accept message in P2 procedure includes PLMN2 in the equivalent PLMN list.
Test procedure
Table 8.6.2.4a.4-1 illustrates the downlink power to be applied for the 3 cells. Column marked "T0" denotes the initial conditions, while columns marked "T1", "T2" are to be applied subsequently. The exact instants on which these values shall be applied are described in the text in this clause.
Parameter |
Unit |
Cell 1 |
Cell 2 |
Cell 3 |
||||||
T0 |
T1 |
T2 |
T0 |
T1 |
T2 |
T0 |
T1 |
T2 |
||
UTRA RF Channel Number |
Mid Range Test Frequency |
Mid Range Test Frequency |
Mid Range Test Frequency |
|||||||
CPICH Ec (FDD) |
dBm/3.84 MHz |
-60 |
OFF |
OFF |
OFF |
-60 |
OFF |
OFF |
OFF |
-60 |
P-CCPCH RSCP(TDD) |
dBm |
-60 |
OFF |
OFF |
OFF |
-60 |
OFF |
OFF |
OFF |
-60 |
PLMN |
PLMN 1 |
PLMN 2 |
PLMN 2 |
a) SS transmits a LOGGING MEASUREMENT CONFIGURATION message with a cell list on Cell 1 and only Cell 3 in the configured cell list. SS changes Cell 1, Cell 2 and Cell 3 power levels, and the UE moves to idle mode on Cell 2.Verify Logging MDT measurements on Cell 2.
b) SS changes Cell 1, Cell 2 and Cell 3 power levels, and the UE moves to idle mode on Cell 3. Verify Logging MDT measurements on Cell 3.
Expected sequence
Step |
Direction |
Message |
Comments |
|
---|---|---|---|---|
UE |
SS |
|||
1 |
<– |
LOGGING MEASUREMENT CONFIGURATION |
SS transmits a LOGGING MEASUREMENT CONFIGURATION message with a cell list on Cell 1. Only Cell 3 is in a configured cell list. |
|
2 |
<– |
RRC CONNECTION RELEASE |
SS transmits a RRC CONNECTION RELEASE message to release the RRC connection. |
|
3 |
–> |
RRC CONNECTION RELEASE COMPLETE |
UE confirms the connection release and returns to Idle mode. |
|
4 |
– |
– |
SS changes Cell 1, Cell 2 and Cell 3 level according to the T1 in Table 8.6.2.4a.4-1. UE performs cell reselection and the UE moves to idle mode on Cell 2. |
|
5 |
– |
Wait 10 seconds for UE logging interval timer to expire at least once. |
||
6 |
<– |
Paging |
SS transmits a Paging message. |
|
7 |
–> |
RRC CONNECTION REQUEST |
The UE transmits an RRC CONNECTION REQUEST message. |
|
8 |
<– |
RRC CONNECTION SETUP |
SS transmit an RRC CONNECTION SETUP message. |
|
9 |
–> |
RRC CONNECTION SETUP COMPLETE |
The UE shall transmit an RRC CONNECTION SETUP COMPLETE message with IE “Logged Meas Available” not present. |
|
10 |
–> |
RRC: INITIAL DIRECT TRANSFER NAS: SERVICE REQUEST |
The UE transmits SERVICE REQUEST message. |
|
11 |
<– |
RRC CONNECTION RELEASE |
SS transmits a RRC CONNECTION RELEASE message to release the RRC connection. |
|
12 |
–> |
RRC CONNECTION RELEASE COMPLETE |
The UE confirms the connection release and returns to Idle mode. |
|
13 |
SS changes Cell 1, Cell 2 and Cell 3 level according to the T2 in Table 8.6.2.4a.4-1. UE performs cell reselection and the UE moves to idle mode on Cell 3. |
|||
14 |
Wait 10 seconds for UE logging interval timer to expire at least once |
|||
15 |
<– |
Paging |
SS transmits a Paging message. |
|
16 |
–> |
RRC CONNECTION REQUEST |
The UE transmits an RRC CONNECTION REQUEST message. |
|
17 |
<– |
RRC CONNECTION SETUP |
SS transmit an RRC CONNECTION SETUP message. |
|
18 |
–> |
RRC CONNECTION SETUP COMPLETE |
The UE shall transmit an RRC CONNECTION SETUP COMPLETE message including IE “Logged Meas Available”. |
|
19 |
–> |
RRC: INITIAL DIRECT TRANSFER NAS: SERVICE REQUEST |
The UE transmits SERVICE REQUEST message. |
|
20 |
<– |
UE INFORMATION REQUEST |
SS send an UE INFORMATION REQUEST message to get logMeasReport. |
|
21 |
–> |
UE INFORMATION RESPONSE |
The UE shall send an UE INFORMATION RESPONSE message with Logged Meas Report of Cell 3. |
Specific message contents
All messages have the same content as defined in 34.108 clause 9 with the following exceptions:
LOGGING MEASUREMENT CONFIGURATION (Step 1)
Information Element |
Value/remark |
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Measurements Configuration Info |
|
– Absolute Time Info |
Set to value corresponding to the absolute time when the message is sent |
– Logging Duration |
10 min |
– Logging Interval |
2.56 |
– Trace reference |
|
– PLMN Identity |
Same as MIB |
– Trace ID |
‘0EF’H |
-Trace recording session |
‘1A’H |
– TCE Id |
‘5’H |
– CHOICE Area Configuration |
|
– Cell IDList |
|
– Cell ID |
Cell 3 |
– PLMN Identity |
PLMN2 |
– PLMN Identity List |
|
– PLMN Identity |
PLMN2 |
RRC CONNECTION SETUP COMPLETE (step 9)
Information Element |
Value/remark |
Message Type |
|
RRC transaction identifier |
The value of this IE is checked to see that it matches the value of the same IE transmitted in the downlink RRC CONNECTION SETUP message. |
Logged Meas Available |
Not present |
RRC CONNECTION SETUP COMPLETE (step 18)
Information Element |
Value/remark |
Message Type |
|
RRC transaction identifier |
The value of this IE is checked to see that it matches the value of the same IE transmitted in the downlink RRC CONNECTION SETUP message. |
Logged Meas Available |
True |
UE INFORMATION RESPONSE (FDD) (Step 21)
Information Element |
Value/remark |
---|---|
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Meas Report |
|
– Absolute Time Info |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace reference |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– PLMN Identity |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace ID |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace recording session |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– TCE Id |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– CHOICE mode |
FDD |
– List of measurements FDD |
At least 1 entry where at least one entry complies to entry with index ‘x’ below. |
– Logged Measurement Info-FDD[x] |
|
– Relative Time Stamp[x] |
Not checked |
– Logged Measurements Serving Cell[x] |
|
– PLMN Identity |
PLMN2 |
– Cell ID[x] |
Cell 3 |
– Primary CCPCH RSCP[x] |
(0..91) |
– CPICH Ec/N0 |
(0..49) |
– Logged Meas Available |
Not checked |
UE INFORMATION RESPONSE (TDD) (Step 21)
Information Element |
Value/remark |
---|---|
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Meas Report |
|
– Absolute Time Info |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace reference |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace recording session |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– PLMN Identity |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace ID |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– TCE Id |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– CHOICE mode |
TDD |
– List of measurements TDD |
At least 1 entry where at least one entry complies to entry with index ‘x’ below. |
– Logged Measurement Info-TDD[x] |
|
– Relative Time Stamp[x] |
Not checked |
– Logged Measurements Serving Cell[x] |
|
– PLMN Identity |
PLMN2 |
– Cell ID |
Cell 3 |
– Primary CCPCH RSCP |
(0..91) |
– Logged Meas Available |
Not checked |
8.6.2.4a.5 Test requirements
At step 9, the UE shall transmit an RRC CONNECTION SETUP COMPLETE message with IE “Logged Meas Available” not present (TP2).
At step 18, the UE shall transmit an RRC CONNECTION SETUP COMPLETE message including IE “Logged Meas Available” (TP1).
At step 21, the UE shall send an UE INFORMATION RESPONSE message with Logged Meas Report of Cell 3(TP1).
8.6.2.5 Logged MDT / Release of logged MDT measurement configuration / Expire of duration timer
8.6.2.5.1 Definition
8.6.2.5.2 Conformance requirement
[TS 25.331, clause 8.5.63.3 (TP1, TP2)]
Upon receiving the LOGGING MEASUREMENT CONFIGURATION message the UE shall:
1> if IE "Logged Measurements Configuration Info" is present:
2> if stored, discard the existing logged measurement configuration as well as the logged measurement information as specified in 8.5.66;
2> store the received IEs "Logging Duration", "Logging Interval", "Area Configuration" if included in IE "Logged Measurements Configuration Info" in variable LOGGED_MEAS_CONFIG and IEs "Absolute Time Info", "Trace reference", "Trace recording session" and "TCE Id" in variable LOGGED_MEAS_REPORT_VARIABLE;
2> store the current Registered PLMN in the IE "PLMN Identity" in variable LOGGED_MEAS_REPORT_VARIABLE;
2> start timer T326 with the timer value set to the IE "Logging Duration".
NOTE: The UE shall not stop timer T326 unless explicitly stated when it moves to another RAT.
1> if IE "Logged ANR configuration Info" is present:
2> if variable LOG_ANR_CONFIG was already stored, discard the existing logged measurement configuration for ANR purpose as well as the associated logged measurement information as specified in 8.5.68;
2> store the received IEs in the IE "Logged ANR configuration Info" in variable LOG_ANR_CONFIG;
2> store the current Registered PLMN in the IE "PLMN Identity" in variable LOG_ANR_REPORT_VARIABLE;
2> store the list of Equivalent PLMNs in the IE "Equivalent PLMN Identity List" in variable LOG_ANR_REPORT_VARIABLE;
2> start timer T327 with the timer value set to the IE "Logging Duration" included in IE "Logged ANR configuration Info".
When in idle mode, CELL_PCH or URA_PCH state and Logged Measurements has been configured, the UE shall:
1> Store the available measurements according to the logged measurements configuration in LOGGED_MEAS_CONFIG variable as specified in subclause 8.5.65.2.
[TS 25.331, clause 8.5.63.4 (TP1)]
When timer T326 expires, the UE shall:
1> release variable LOGGED_MEAS_CONFIG.
The UE is allowed to release stored logged measurements, i.e. to release LOGGED_MEAS_REPORT_VARIABLE 48 hours after T326 expiry.
[TS 25.331, clause 8.5.64.3 (TP2)]
UE Shall:
1> if IE "Logged Measurements Report Request" is present:
2> if Registered PLMN is the same as the IE "PLMN Identity" stored in variable LOGGED_MEAS_REPORT_VARIABLE:
3> if an IE "Logged Measurement Info-FDD" or "Logged Measurement Info-TDD" in variable LOGGED_MEAS_REPORT_VARIABLE is present:
- set IE "Logged Meas Report" in the UE INFORMATION RESPONSE as follows:
5> include the IE "Absolute Time Info" and set it to the value of the IE "Absolute Time Info" in the variable LOGGED_MEAS_REPORT_VARIABLE;
5> include the IE "Trace reference" and set it to the value of IE "Trace reference" in the variable LOGGED_MEAS_REPORT_VARIABLE;
5> include the IE "Trace recording session" and set it to the value of IE "Trace recording session" in the variable LOGGED_MEAS_REPORT_VARIABLE;
5> include the IE "TCE Id" and set it to the value of IE "TCE Id" in the variable LOGGED_MEAS_REPORT_VARIABLE;
5> include the IEs "Logged Measurement Info-FDD" or "Logged Measurement Info-TDD" and set it to include, in the same order as logged, one or more entries from LOGGED_MEAS_REPORT_VARIABLE;
5> clear the logged measurement results included in the list of IEs "Logged Measurement Info-FDD" or "Logged Measurement Info-TDD" from LOGGED_MEAS_REPORT_VARIABLE;
5> if the variable LOGGED_MEAS_REPORT_VARIABLE is not empty:
6> include IE "Logged Meas Available";
2> transmit a UE INFORMATION RESPONSE message on the uplink DCCH using AM RLC.
1> if IE "Logged ANR Report Request" is present:
2> if Registered PLMN is the same as one of the PLMNs in the IE "PLMN Identity" or IE "Equivalent PLMN Identity List" stored in variable LOG_ANR_REPORT_VARIABLE:
3> if IE "Logged ANR Report Info" in variable LOG_ANR_REPORT_VARIABLE is present:
4> set IEs "Logged ANR Report Info" in the UE INFORMATION RESPONSE as follows:
5> include the IEs "Logged ANR Report Info List" and set it to include entries from LOG_ANR_REPORT_VARIABLE;
5> clear the logged measurement results included in the list of IEs "Logged ANR Report Info List" from the LOG_ANR_REPORT_VARIABLE;
5> clear the variable LOG_ANR_CONFIG and stop timer T327.
2> transmit a UE INFORMATION RESPONSE message on the uplink DCCH using AM RLC.
[TS 25.331, clause 8.5.65.2 (TP1, TP2)]
While T326 is running, the UE shall:
1> perform this logging in accordance with the following:
2> perform the logging while camping normally on an UTRA cell and the RPLMN of the UE is the same as the PLMN Identity stored in LOGGED_MEAS_REPORT_VARIABLE and, if the IE "Area Configuration" is present in variable LOGGED_MEAS_CONFIG, that is part of the concerned area;
2> perform the logging at regular intervals, as defined by the IE "Logging Interval" in variable LOGGED_MEAS_CONFIG;
2> when adding a logged measurement entry in variable LOGGED_MEAS_REPORT_VARIABLE, include the fields in accordance with the following:
3> set the IE "Relative Time Stamp" to indicate time relative to the moment at which the logged measurement configuration was received;
3> if GNSS location information became available during the last logging interval:
4> if the UE has been able to calculate a 3-dimensional position:
5> set IE "Ellipsoid point with altitude" to include the location coordinates;
4>else:
5> set IE "Ellipsoid point" to include the location coordinates:
3> set the IE "Cell ID" to indicate cell identity of the cell the UE is camping on obtained from system information;
3> set the IE "CPICH Ec/N0" and "CPICH RSCP" to include measured quantities of the cell that the UE is camping on for UTRA FDD;
3> set the "P-CCPCH RSCP" to include measured quantities for the cell that the UE is camping on for UTRA 1.28 Mcps TDD;
3> set the IE "Logged Measurements Intra Frequency Neighbouring Cells list", "Logged Measurements Inter Frequency list", "Logged Measurements E-UTRA frequency list", in order of decreasing ranking quantity as used for cell re-selection in each frequency for at most the following number of neighbouring cells; 6 intra-frequency and 3 inter-frequency neighbours per frequency as well as 3 inter-RAT neighbours, per frequency per RAT;
3> set the IE "Logged Measurements GSM Neighbouring Cells list" in order of decreasing RXLEV.
NOTE: The UE includes, only once, the latest available results of the measurement performed for cell reselection, which are performed in accordance with the regular performance requirements as specified in [19].
2> when the memory reserved for the logging of measurements becomes full, stop timer T326 and performs the same actions as performed upon expiry of T326, as specified in 8.5.63.4.
Reference
3GPP TS 25.331 clauses 8.5.63.3, 8.5.63.4, 8.5.64.3 and 8.5.65.2
8.6.2.5.3 Test Purpose
1. Verify release of Logged MDT measurement configuration up on stop or expire of logging duration timer.
2. Verify that UE, when being requested to report logged MDT measurements before the duration timer has expired, deletes the reported logged MDT measurements.
8.6.2.5.4 Method of test
Initial Condition
System Simulator: Cell 1 is active.
UE: PS-DCCH+DTCH_DCH (state 6-10) in Cell 1 as specified in clause 7.4 of TS 34.108.
Test Procedure
The UE is in CELL_DCH state of cell 1. SS transmits a LOGGING MEASUREMENT CONFIGURATION message to the UE to configure logged measurements.
SS transmits an RRC CONNECTION RELEASE message to the UE to disconnect the connection.
The UE transmits an RRC CONNECTION RELEASE COMPLETE message using unacknowledged mode
Wait 5s to allow UE to activate logging.
SS request Logged Meas Report until all the Logged Meas Report has been transmitted.
SS transmits a UE INFORMATION REQUEST message, and the IE "Logged Measurements Report Request" is present.
The UE shall transmit a UE INFORMATION REPONSE message, without IE “Logged Meas Report ".
SS transmits an RRC CONNECTION RELEASE message to the UE to disconnect the connection.
The UE transmits an RRC CONNECTION RELEASE COMPLETE message using unacknowledged mode
Wait 10 minutes for UE performing the logging at regular time intervals as to ensure timer T326 has expired.
The UE transmits an RRC CONNECTION REQUEST message to SS.
SS transmits an RRC CONNECTION SETUP message to the UE.
The UE transmits an RRC CONNECTION SETUP COMPLETE message to SS, and enters CELL_DCH state.
SS request Logged Meas Report until all the Logged Meas Report has been transmitted.
SS transmits an RRC CONNECTION RELEASE message to the UE to disconnect the connection.
The UE transmits an RRC CONNECTION RELEASE COMPLETE message using unacknowledged mode.
Wait 10 s.
The UE transmits an RRC CONNECTION REQUEST message to SS.
SS transmits an RRC CONNECTION SETUP message to the UE.
The UE transmits an RRC CONNECTION SETUP COMPLETE message to SS, and without IE "Logged Meas Available"
Expected Sequence
Step |
Direction |
Message |
Comment |
|
---|---|---|---|---|
UE |
SS |
|||
1 |
|
LOGGING MEASUREMENT CONFIGURATION |
Include IE “Logged Measurements Configuration Info”, with “Logging Interval” set as 2.56s and “Logging Duration” set as 10min. |
|
2 |
|
RRC CONNECTION RELEASE |
||
3 |
|
RRC CONNECTION RELEASE COMPLETE |
||
4 |
Wait 5s to allow UE to active logging. |
|||
5 |
|
RRC CONNECTION REQUEST |
By outgoing call operation. |
|
6 |
|
RRC CONNECTION SETUP |
||
7 |
|
RRC CONNECTION SETUP COMPLETE |
||
7A |
|
RRC: INITIAL DIRECT TRANSFER NAS: SERVICE REQUEST |
The UE transmits SERVICE REQUEST message. |
|
– |
– |
– |
EXCEPTION: In parallel to the events described in steps 8 to 11 below, steps 6 to 13 defined in TS34.108 clause 7.2.4.2 occurs to complete service request procedure. |
|
8 |
|
UE INFORMATION REQUEST |
SS transmits a UE INFORMATION REQUEST message with IE "Logged Measurements Report Request" set to “true”. |
|
9 |
|
UE INFORMATION RESPONSE |
||
EXCEPTION: In case the IE “Logged Meas Available” present in IE “Logged Meas Report” in message UE INFORMATION RESPONSE in step 9, steps 9a1 and 9a2 will be executed. |
||||
9a1 |
|
UE INFORMATION REQUEST |
SS transmits a UE INFORMATION REQUEST message with IE "Logged Measurements Report Request" set to “true”. |
|
9a2 |
|
UE INFORMATION RESPONSE |
||
EXCEPTION: In case the IE “Logged Meas Available” present in IE “Logged Meas Report” in message UE INFORMATION RESPONSE in step 9a2, steps 9a1 and 9a2 will be executed again. |
||||
10 |
|
UE INFORMATION REQUEST |
SS transmits a UE INFORMATION REQUEST message with IE "Logged Measurements Report Request" set to “true”. |
|
11 |
|
UE INFORMATION RESPONSE |
The UE shall send a UE INFORMATION RESPONSE message, without IE “Logged Meas Report”. |
|
12 |
|
RRC CONNECTION RELEASE |
||
13 |
|
RRC CONNECTION RELEASE COMPLETE |
The UE sends this message before it completes state transition. |
|
14 |
Wait 10 min for UE performing the logging at regular time intervals as to ensure timer T326 has expired. |
|||
15 |
|
RRC CONNECTION REQUEST |
By outgoing call operation. |
|
16 |
|
RRC CONNECTION SETUP |
||
17 |
|
RRC CONNECTION SETUP COMPLETE |
||
17A |
|
RRC: INITIAL DIRECT TRANSFER NAS: SERVICE REQUEST |
The UE transmits SERVICE REQUEST message. |
|
– |
– |
– |
EXCEPTION: In parallel to the events described in steps 18 to 19a2 below, steps 6 to 13 defined in TS34.108 clause 7.2.4.2 occurs to complete service request procedure. |
|
18 |
|
UE INFORMATION REQUEST |
SS transmits a UE INFORMATION REQUEST message with IE "Logged Measurements Report Request" set to “true”. |
|
19 |
|
UE INFORMATION RESPONSE |
The UE sends a UE INFORMATION RESPONSE message; include IE “Logged Meas Report” of Cell 1. |
|
EXCEPTION: In case the IE “Logged Meas Available” present in IE “Logged Meas Report” in message UE INFORMATION RESPONSE in step 19, steps 19a1 and 19a2 will be executed. |
||||
19a1 |
|
UE INFORMATION REQUEST |
SS transmits a UE INFORMATION REQUEST message with IE "Logged Measurements Report Request" set to “true”. |
|
19a2 |
|
UE INFORMATION RESPONSE |
||
EXCEPTION: In case the IE “Logged Meas Available” present in IE “Logged Meas Report” in message UE INFORMATION RESPONSE in step 19a2, steps 19a1 and 19a2 will be executed again. |
||||
20 |
|
RRC CONNECTION RELEASE |
||
21 |
|
RRC CONNECTION RELEASE COMPLETE |
||
Void |
Wait 10s. |
|||
22 |
|
RRC CONNECTION REQUEST |
By outgoing call operation. |
|
23 |
|
RRC CONNECTION SETUP |
||
24 |
|
RRC CONNECTION SETUP COMPLETE |
The UE shall transmit a RRC CONNECTION SETUP COMPLETE message, without IE “Logged Meas Available”. |
Specific Message Contents
All messages have the same content as defined in 34.108 clause 9 with the following exceptions:
LOGGING MEASUREMENT CONFIGURATION (Step 1)
Information Element |
Value/remark |
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Measurements Configuration Info |
|
– Absolute Time Info |
Set to value corresponding to the absolute time when the message is sent |
– Logging Duration |
10 min |
– Logging Interval |
2.56 |
– Trace reference |
|
– PLMN Identity |
Same as MIB |
– Trace ID |
‘0EF’H |
-Trace recording session |
‘1A’H |
– TCE Id |
‘5’H |
– CHOICE Area Configuration |
Not present |
UE INFORMATION REQUEST (Step 8 and 10)
Information Element |
Value/remark |
---|---|
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Measurements Report Request |
TRUE |
Logged ANR Report Request |
Not Present |
UE INFORMATION RESPONSE (FDD) (Step 9)
Information Element |
Value/remark |
---|---|
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Meas Report |
|
– Absolute Time Info |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace reference |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– PLMN Identity |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace ID |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace recording session |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– TCE Id |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– CHOICE mode |
FDD |
– List of measurements FDD |
At least 1 entry where at least one entry complies to entry with index ‘x’ below. |
– Logged Measurement Info-FDD[x] |
|
– Relative Time Stamp[x] |
Not checked |
– Logged Measurements Serving Cell[x] |
|
– Cell ID |
Cell 1 |
– Primary CCPCH RSCP |
(0..91) |
– CPICH Ec/N0 |
(0..49) |
– Logged Meas Available |
Not present or TRUE |
UE INFORMATION RESPONSE (TDD) (Step 9)
Information Element |
Value/remark |
---|---|
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Meas Report |
|
– Absolute Time Info |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace reference |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– PLMN Identity |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace ID |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace recording session |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– TCE Id |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– CHOICE mode |
TDD |
– List of measurements TDD |
At least 1 entry where at least one entry complies to entry with index ‘x’ below. |
– Logged Measurement Info-TDD[x] |
|
– Relative Time Stamp[x] |
Not checked |
– Logged Measurements Serving Cell[x] |
|
– Cell ID |
Cell 1 |
– Primary CCPCH RSCP |
(0..91) |
– Logged Meas Available |
Not present or TRUE |
UE INFORMATION RESPONSE (FDD) (Step 9a2)
Information Element |
Value/remark |
---|---|
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Meas Report |
|
– Absolute Time Info |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace reference |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– PLMN Identity |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace ID |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace recording session |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– TCE Id |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– CHOICE mode |
FDD |
– List of measurements FDD |
At least 1 entry where at least one entry complies to entry with index ‘x’ below. |
– Logged Measurement Info-FDD[x] |
|
– Relative Time Stamp[x] |
Not checked |
– Logged Measurements Serving Cell[x] |
|
– Cell ID |
Cell 1 |
– Primary CCPCH RSCP |
(0..91) |
– CPICH Ec/N0 |
(0..49) |
– Logged Meas Available |
Not present or TRUE |
UE INFORMATION RESPONSE (TDD) (Step 9a2)
Information Element |
Value/remark |
---|---|
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Meas Report |
|
– Absolute Time Info |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace reference |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– PLMN Identity |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace ID |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace recording session |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– TCE Id |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– CHOICE mode |
TDD |
– List of measurements TDD |
At least 1 entry where at least one entry complies to entry with index ‘x’ below. |
– Logged Measurement Info-TDD[x] |
|
– Relative Time Stamp[x] |
Not checked |
– Logged Measurements Serving Cell[x] |
|
– Cell ID |
Cell 1 |
– Primary CCPCH RSCP |
(0..91) |
– Logged Meas Available |
Not present or TRUE |
UE INFORMATION RESPONSE (Step 11)
Information Element |
Value/remark |
---|---|
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Meas Report |
Not present |
UE INFORMATION RESPONSE (FDD) (Step 19)
Information Element |
Value/remark |
---|---|
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Meas Report |
|
– Absolute Time Info |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace reference |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– PLMN Identity |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace ID |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace recording session |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– TCE Id |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– CHOICE mode |
FDD |
– List of measurements FDD |
At least 1 entry where at least one entry complies to entry with index ‘x’ below. |
– Logged Measurement Info-FDD[x] |
|
– Relative Time Stamp[x] |
Not checked |
– Logged Measurements Serving Cell[x] |
|
– Cell ID |
Cell 1 |
– Primary CCPCH RSCP |
(0..91) |
– CPICH Ec/N0 |
(0..49) |
– Logged Meas Available |
Not present or TRUE |
UE INFORMATION RESPONSE (TDD) (Step 19)
Information Element |
Value/remark |
---|---|
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Meas Report |
|
– Absolute Time Info |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace reference |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– PLMN Identity |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace ID |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace recording session |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– TCE Id |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– CHOICE mode |
TDD |
– List of measurements TDD |
At least 1 entry where at least one entry complies to entry with index ‘x’ below. |
– Logged Measurement Info-TDD[x] |
|
– Relative Time Stamp[x] |
Not checked |
– Logged Measurements Serving Cell[x] |
|
– Cell ID |
Cell 1 |
– Primary CCPCH RSCP |
(0..91) |
– Logged Meas Available |
Not present or TRUE |
UE INFORMATION RESPONSE (FDD) (Step 19a2)
Information Element |
Value/remark |
---|---|
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Meas Report |
|
– Absolute Time Info |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace reference |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– PLMN Identity |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace ID |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace recording session |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– TCE Id |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– CHOICE mode |
FDD |
– List of measurements FDD |
At least 1 entry where at least one entry complies to entry with index ‘x’ below. |
– Logged Measurement Info-FDD[x] |
|
– Relative Time Stamp[x] |
Not checked |
– Logged Measurements Serving Cell[x] |
|
– Cell ID |
Cell 1 |
– Primary CCPCH RSCP |
(0..91) |
– CPICH Ec/N0 |
(0..49) |
– Logged Meas Available |
Not present or TRUE |
UE INFORMATION RESPONSE (TDD) (Step 19a2)
Information Element |
Value/remark |
---|---|
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Meas Report |
|
– Absolute Time Info |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace reference |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– PLMN Identity |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace ID |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace recording session |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– TCE Id |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– CHOICE mode |
TDD |
– List of measurements TDD |
At least 1 entry where at least one entry complies to entry with index ‘x’ below. |
– Logged Measurement Info-TDD[x] |
|
– Relative Time Stamp[x] |
Not checked |
– Logged Measurements Serving Cell[x] |
|
– Cell ID |
Cell 1 |
– Primary CCPCH RSCP |
(0..91) |
– Logged Meas Available |
Not present or TRUE |
RRC CONNECTION SETUP COMPLETE (step 24)
Information Element |
Value/remark |
Message Type |
|
RRC transaction identifier |
The value of this IE is checked to see that it matches the value of the same IE transmitted in the downlink RRC CONNECTION SETUP message. |
Logged Meas Available |
Not present |
8.6.2.5.5 Test requirement
At step 11, the UE shall send an UE INFORMATION RESPONSE message, without IE “Logged Meas Report” (TP2).
At step 24, the UE shall transmit a RRC CONNECTION SETUP COMPLETE message, without IE “Logged Meas Available” (TP1).
8.6.2.6 Logged MDT / Release of logged MDT measurement configuration / Reception of new logged measurement configuration, Detach or UE power off
8.6.2.6.1 Definition
8.6.2.6.2 Conformance requirement
[TS 25.331, clause 8.5.63.3 (TP1, TP2)]
Upon receiving the LOGGING MEASUREMENT CONFIGURATION message the UE shall:
1> if IE "Logged Measurements Configuration Info" is present:
2> if stored, discard the existing logged measurement configuration as well as the logged measurement information as specified in 8.5.66;
2> store the received IEs "Logging Duration", "Logging Interval", "Area Configuration" if included in IE "Logged Measurements Configuration Info" in variable LOGGED_MEAS_CONFIG and IEs "Absolute Time Info", "Trace reference", "Trace recording session" and "TCE Id" in variable LOGGED_MEAS_REPORT_VARIABLE;
2> store the current Registered PLMN in the IE "PLMN Identity" in variable LOGGED_MEAS_REPORT_VARIABLE;
2> start timer T326 with the timer value set to the IE "Logging Duration".
NOTE: The UE shall not stop timer T326 unless explicitly stated when it moves to another RAT.
1> if IE "Logged ANR configuration Info" is present:
2> if variable LOG_ANR_CONFIG was already stored, discard the existing logged measurement configuration for ANR purpose as well as the associated logged measurement information as specified in 8.5.68;
2> store the received IEs in the IE "Logged ANR configuration Info" in variable LOG_ANR_CONFIG;
2> store the current Registered PLMN in the IE "PLMN Identity" in variable LOG_ANR_REPORT_VARIABLE;
2> store the list of Equivalent PLMNs in the IE "Equivalent PLMN Identity List" in variable LOG_ANR_REPORT_VARIABLE;
2> start timer T327 with the timer value set to the IE "Logging Duration" included in IE "Logged ANR configuration Info".
When in idle mode, CELL_PCH or URA_PCH state and Logged Measurements has been configured, the UE shall:
1> Store the available measurements according to the logged measurements configuration in LOGGED_MEAS_CONFIG variable as specified in subclause 8.5.65.2.
[TS 25.331, clause 8.5.66.2 (TP1, TP2)]
The UE initiates the procedure upon receiving a logged measurement configuration in UTRAN or in another RAT. The UE also shall initiate the procedure upon switch off or detach.
The UE shall:
1> if stored, discard the existing logged measurement configuration as well as the logged measurement information, i.e. release the UE variables LOGGED MEAS CONFIG and LOGGED_MEAS_REPORT_VARIABLE and stop timer T326.
Reference
TS 25.331 clauses 8.5.63.3, 8.5.66.2
8.6.2.6.3 Test Purpose
1. Verify release of logged measurement configuration and logs up on reception of new logged measurement configuration
2. Verify release of logged measurement configuration and logs upon UE switch off or detach
8.6.2.6.4 Method of test
Initial Condition
System Simulator: Cell 1 is active.
UE: PS-DCCH+DTCH_DCH (state 6-10) in Cell 1 as specified in clause 7.4 of TS 34.108.
Related ICS/IXIT statement(s)
Switch off button Yes/No.
Test Procedure
The UE is in CELL_DCH state of cell 1. SS transmits a LOGGING MEASUREMENT CONFIGURATION message to the UE to configure logged measurements.
SS transmits an RRC CONNECTION RELEASE message to the UE to disconnect the connection.
The UE transmits an RRC CONNECTION RELEASE COMPLETE message using unacknowledged mode
Wait 10s to allow UE to activate logging.
The UE transmits an RRC CONNECTION REQUEST message to SS.
SS transmits an RRC CONNECTION SETUP message to the UE.
The UE transmits an RRC CONNECTION SETUP COMPLETE message to SS, and enters CELL_DCH state.
SS transmits a LOGGING MEASUREMENT CONFIGURATION message to the UE to configure logged measurements.
SS transmits a UE INFORMATION REQUEST message, and the IE "Logged Measurements Report Request" is present.
The UE shall transmit a UE INFORMATION REPONSE message, without IE “Logged Meas Report ".
SS transmits an RRC CONNECTION RELEASE message to the UE to disconnect the connection.
The UE transmits an RRC CONNECTION RELEASE COMPLETE message using unacknowledged mode
Wait 10s to allow UE to activate logging.
The UE transmits an RRC CONNECTION REQUEST message to SS.
SS transmits an RRC CONNECTION SETUP message to the UE.
The UE transmits an RRC CONNECTION SETUP COMPLETE message to SS, and enters CELL_DCH state.
SS transmits a UE INFORMATION REQUEST message, and the IE "Logged Measurements Report Request" is present.
The UE shall transmit a UE INFORMATION REPONSE message, without IE “Logged Meas Report” based on the message LOGGING MEASUREMENT CONFIGURATION in step 1.
SS transmits an RRC CONNECTION RELEASE message to the UE to disconnect the connection.
The UE transmits an RRC CONNECTION RELEASE COMPLETE message using unacknowledged mode.
Wait 10s to allow UE to activate logging.
The UE is switched off, or detaches from the network.
The UE is switched on, or attaches to the network.
The UE registered on the network.
Wait 10s
The UE transmits an RRC CONNECTION REQUEST message to SS.
SS transmits an RRC CONNECTION SETUP message to the UE.
The UE transmits an RRC CONNECTION SETUP COMPLETE message to SS, and without IE "Logged Meas Available"
Expected Sequence
Step |
Direction |
Message |
Comment |
|
---|---|---|---|---|
UE |
SS |
|||
1 |
|
LOGGING MEASUREMENT CONFIGURATION |
Include IE “Logged Measurements Configuration Info”, with “Logging Interval” set as 2.56s and “Logging Duration” set as 10min. |
|
2 |
|
RRC CONNECTION RELEASE |
||
3 |
|
RRC CONNECTION RELEASE COMPLETE |
||
4 |
Wait 10s to allow UE to activate logging. |
|||
5 |
|
RRC CONNECTION REQUEST |
By outgoing call operation. |
|
6 |
|
RRC CONNECTION SETUP |
||
7 |
|
RRC CONNECTION SETUP COMPLETE |
||
7A |
|
RRC: INITIAL DIRECT TRANSFER NAS: SERVICE REQUEST |
The UE transmits SERVICE REQUEST message. |
|
– |
– |
– |
EXCEPTION: In parallel to the events described in steps 8 to 11 below, steps 6 to 13 defined in TS34.108 clause 7.2.4.2 occurs to complete service request procedure. |
|
8 |
|
LOGGING MEASUREMENT CONFIGURATION |
Include IE “Logged Measurements Configuration Info”, with “Logging Interval” set as 2.56s and “Logging Duration” set as 10min. |
|
9 |
|
UE INFORMATION REQUEST |
SS transmits a UE INFORMATION REQUEST message with IE "Logged Measurements Report Request" set to “true”. |
|
10 |
|
UE INFORMATION RESPONSE |
The UE shall send a UE INFORMATION RESPONSE message, without IE “Logged Meas Report”. |
|
11 |
|
RRC CONNECTION RELEASE |
||
12 |
|
RRC CONNECTION RELEASE COMPLETE |
The UE sends this message before it completes state transition. |
|
13 |
Wait 10s to allow UE to activate logging. |
|||
14 |
|
RRC CONNECTION REQUEST |
By outgoing call operation. |
|
15 |
|
RRC CONNECTION SETUP |
||
16 |
|
RRC CONNECTION SETUP COMPLETE |
||
16A |
–> |
RRC: INITIAL DIRECT TRANSFER NAS: SERVICE REQUEST |
The UE transmits SERVICE REQUEST message. |
|
– |
– |
– |
EXCEPTION: In parallel to the events described in steps 17 to 18 below, steps 6 to 13 defined in TS34.108 clause 7.2.4.2 occurs to complete service request procedure. |
|
17 |
|
UE INFORMATION REQUEST |
SS transmits a UE INFORMATION REQUEST message with IE "Logged Measurements Report Request" set to “true”. |
|
18 |
|
UE INFORMATION RESPONSE |
The UE shall send a UE INFORMATION RESPONSE message, with IE “Logged Meas Report” present. And the IE “Logged Meas Report” does not include logged measurement reports based on the message LOGGING MEASUREMENT CONFIGURATION in step 1. |
|
19 |
|
RRC CONNECTION RELEASE |
||
20 |
|
RRC CONNECTION RELEASE COMPLETE |
||
21 |
Wait 10s to allow UE to activate logging. |
|||
22 |
The UE is powered down or switched off and initiates a detach. |
|||
23 |
The UE is powered up or switched on and initiates an attach. |
|||
24-36 |
Steps 1 to 13 of the generic test procedure in TS 34.108 subclause 7.2.2.2.3 are performed to complete the registration on the network. |
|||
37 |
Wait 10s to allow UE to activate logging. |
|||
38 |
|
RRC CONNECTION REQUEST |
By outgoing call operation. |
|
39 |
|
RRC CONNECTION SETUP |
||
40 |
|
RRC CONNECTION SETUP COMPLETE |
The UE shall transmit a RRC CONNECTION SETUP COMPLETE message, without IE “Logged Meas Available”. |
Specific Message Contents
All messages have the same content as defined in 34.108 clause 9 with the following exceptions:
LOGGING MEASUREMENT CONFIGURATION (Step 1 and 8)
Information Element |
Value/remark |
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Measurements Configuration Info |
|
– Absolute Time Info |
Set to value corresponding to the absolute time when the message is sent |
– Logging Duration |
10 min |
– Logging Interval |
2.56 |
– Trace reference |
|
– PLMN Identity |
Same as MIB |
– Trace ID |
‘0EF’H |
-Trace recording session |
‘1A’H |
– TCE Id |
‘5’H |
– CHOICE Area Configuration |
Not present |
RRC CONNECTION SETUP COMPLETE (step 7)
Information Element |
Value/remark |
Message Type |
|
RRC transaction identifier |
The value of this IE is checked to see that it matches the value of the same IE transmitted in the downlink RRC CONNECTION SETUP message. |
Logged Meas Available |
TRUE |
UE INFORMATION REQUEST (Steps 9 and 17)
Information Element |
Value/remark |
---|---|
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Measurements Report Request |
TRUE |
Logged ANR Report Request |
Not Present |
UE INFORMATION RESPONSE (Step 10)
Information Element |
Value/remark |
---|---|
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Meas Report |
Not present |
UE INFORMATION RESPONSE (FDD) (Step 18)
Information Element |
Value/remark |
---|---|
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Meas Report |
|
– Absolute Time Info |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 8 |
– Trace reference |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 8 |
– PLMN Identity |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 8 |
– Trace ID |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 8 |
– Trace recording session |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 8 |
– TCE Id |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 8 |
– CHOICE mode |
FDD |
– List of measurements FDD |
At least 1 entry where at least one entry complies to entry with index ‘x’ below. |
– Logged Measurement Info-FDD[x] |
|
– Relative Time Stamp[x] |
Not checked |
– Logged Measurements Serving Cell[x] |
|
– Cell ID[x] |
Cell 1 |
– Primary CCPCH RSCP[x] |
(0..91) |
– CPICH Ec/N0 |
(0..49) |
UE INFORMATION RESPONSE (TDD) (Step 18)
Information Element |
Value/remark |
---|---|
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Meas Report |
|
– Absolute Time Info |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 8 |
– Trace reference |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 8 |
– PLMN Identity |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 8 |
– Trace ID |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 8 |
– Trace recording session |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 8 |
– TCE Id |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 8 |
– CHOICE mode |
TDD |
– List of measurements TDD |
At least 1 entry where at least one entry complies to entry with index ‘x’ below. |
– Logged Measurement Info-TDD[x] |
|
– Relative Time Stamp[x] |
Not checked |
– Logged Measurements Serving Cell[x] |
|
– Cell ID |
Cell 1 |
– Primary CCPCH RSCP |
(0..91) |
RRC CONNECTION SETUP COMPLETE (step 40)
Information Element |
Value/remark |
Message Type |
|
RRC transaction identifier |
The value of this IE is checked to see that it matches the value of the same IE transmitted in the downlink RRC CONNECTION SETUP message. |
Logged Meas Available |
Not present |
8.6.2.6.5 Test requirement
At step 10, the UE shall send a UE INFORMATION RESPONSE message, without IE “Logged Meas Report” (TP1).
At step18, the UE shall send a UE INFORMATION RESPONSE message, with IE “Logged Meas Report”. And the IE “Logged Meas Report” does not include logged measurement reports based on the message LOGGING MEASUREMENT CONFIGURATION in step 1. (TP1).
At step 40, the UE shall transmit a RRC CONNECTION SETUP COMPLETE message, without IE “Logged Meas Available” (TP2).
8.6.2.7 Logged MDT / Maintaining logged measurement configuration / UE state transitions and mobility
8.6.2.7.1 Definition
8.6.2.7.2 Conformance requirement
[TS 25.304, clause 5.7 (TP1, TP2, TP3, TP4)]
The UE may be configured to perform logging of measurement results in idle mode, CELL_PCH and URA_PCH state with LOGGING MEASUREMENT CONFIGURATION message specified in TS 25.331 [4]. This configuration is valid while the logging duration timer is running.
If the configuration of logged measurements is valid, the UE shall perform logging of measurement results if all of the following conditions are met:
– the UE is in camped normally state in idle mode, CELL_PCH or URA_PCH state;
– RPLMN of the UE is the same as the RPLMN at the point of time of LOGGING MEASUREMENT CONFIGURATION message reception
– the UE is camped on a cell belonging to Area Configuration (see TS 25.331 [4]), if configured;
– the UE is camped on the RAT where the logged measurement configuration was received.
Otherwise, the logging of measurement results shall be suspended.
NOTE: Even if logging of measurement results is suspended, the logging duration timer and time stamp will continue, and the logged measurement configuration and corresponding log are kept.
[TS 25.331, clause 8.5.65.2 (TP2, TP3, TP4)]
While T326 is running, the UE shall:
1> perform this logging in accordance with the following:
2> perform the logging while camping normally on an UTRA cell and the RPLMN of the UE is the same as the PLMN Identity stored in LOGGED_MEAS_REPORT_VARIABLE and, if the IE "Area Configuration" is present in variable LOGGED_MEAS_CONFIG, that is part of the concerned area;
2> perform the logging at regular intervals, as defined by the IE "Logging Interval" in variable LOGGED_MEAS_CONFIG;
2> when adding a logged measurement entry in variable LOGGED_MEAS_REPORT_VARIABLE, include the fields in accordance with the following:
3> set the IE "Relative Time Stamp" to indicate time relative to the moment at which the logged measurement configuration was received;
3> if GNSS location information became available during the last logging interval:
4> if the UE has been able to calculate a 3-dimensional position:
5> set IE "Ellipsoid point with altitude" to include the location coordinates;
4>else:
5> set IE "Ellipsoid point" to include the location coordinates:
3> set the IE "Cell ID" to indicate cell identity of the cell the UE is camping on obtained from system information;
3> set the IE "CPICH Ec/N0" and "CPICH RSCP" to include measured quantities of the cell that the UE is camping on for UTRA FDD;
3> set the "P-CCPCH RSCP" to include measured quantities for the cell that the UE is camping on for UTRA 1.28 Mcps TDD;
3> set the IE "Logged Measurements Intra Frequency Neighbouring Cells list", "Logged Measurements Inter Frequency list", "Logged Measurements E-UTRA frequency list", in order of decreasing ranking quantity as used for cell re-selection in each frequency for at most the following number of neighbouring cells; 6 intra-frequency and 3 inter-frequency neighbours per frequency as well as 3 inter-RAT neighbours, per frequency per RAT;
3> set the IE "Logged Measurements GSM Neighbouring Cells list" in order of decreasing RXLEV.
NOTE: The UE includes, only once, the latest available results of the measurement performed for cell reselection, which are performed in accordance with the regular performance requirements as specified in [19].
2> when the memory reserved for the logging of measurements becomes full, stop timer T326 and performs the same actions as performed upon expiry of T326, as specified in 8.5.63.4.
[TS 25.331, clause 13.4.48 (TP2, TP3, TP4)]
This variable contains parameters related to Logged Measurements. This variable shall not be deleted upon transition to idle mode and when the UE moves to another RAT.
Information Element/Group name |
Need |
Multi |
Type and reference |
Semantics description |
Version |
Logged Measurements Configuration Info |
MP |
Logged Measurements Configuration Info 10.3.7.132 |
REL-10 |
[TS 25.331, clause 13.4.49 (TP2, TP3, TP4)]
This variable includes the logged measurements information. This variable shall not be deleted upon transition to Idle mode and when the UE moves to another RAT. The UE shall store the logged measurements during 48 hours after expiry of the timer T326.
Information Element/Group name |
Need |
Multi |
Type and reference |
Semantics description |
Version |
Trace reference |
MP |
Trace Reference 10.3.7.133 |
Parameter trace reference: See TS 32.422 [81] |
REL-10 |
|
Trace recording session |
MP |
Trace Recording Session 10.3.7.134 |
Parameter trace recording session reference: See TS 32.422 [81] |
REL-10 |
|
TCE Id |
MP |
TCE Id 10.3.7.135 |
Parameter TCE Id: See TS 32.422 [81] |
REL-10 |
|
PLMN Identity |
MP |
PLMN identity 10.3.1.11 |
REL-10 |
||
Absolute Time Info |
MP |
Bit Sting (48) |
Indicates the reference to network absolute time absoluteTimeInfo provided at the point of measurement logging configuration. Format is YY-MM-DD HH:MM:SS using BCD encoding |
REL-10 |
|
CHOICE mode |
MP |
REL-10 |
|||
>FDD |
REL-10 |
||||
>>List of measurements FDD |
0..MaxLoggedMeas |
REL-10 |
|||
>>>Logged Measurement Info-FDD |
MP |
Logged Measurement Info-FDD 10.3.7.129 |
REL-10 |
||
>TDD |
REL-10 |
||||
>>List of measurements TDD |
0..MaxLoggedMeas |
REL-10 |
|||
>>>Logged Measurement Info-TDD |
MP |
Logged Measurement Info-TDD 10.3.7.130 |
REL-10 |
Reference
TS 25.304 clause 5.7 and TS 25.331 clauses 8.5.65.2, 13.4.48, 13.4.49
8.6.2.7.3 Test Purpose
1. Verify that UE is not indicating availability of Logged MDT measurements when UE has moved to a non MDT PLMN cell
2. Verify that logged measurement configurations and logs are maintained despite periods of interruptions due to UE transitions to CELL_FACH or CELL_DCH
3. Verify that logged measurement configurations and logs are maintained despite periods of interruptions due to UE change to a non MDT PLMN cell
4. Verify that logging is stopped (but duration timer is kept running) when UE changes from "camp normally" state to "any cell selection" or "camp on any cell" states and resumes logging when returning to "camp normally" state
8.6.2.7.4 Method of test
Initial Condition
System Simulator: 2 cells, Cell 1 and Cell 2.
UE: PS-DCCH+DTCH_DCH (state 6-10) in Cell 1 as specified in clause 7.4 of TS 34.108.
Test Procedure
Table 8.6.2.7 illustrates the downlink power to be applied for the 2 cells at various time instants of the test execution. Column marked "T0" denotes the initial condition. Subsequent configurations marked “T1”, “T2”, “T3”and “T4” are applied at the points indicated described in the texts in this clause.
Table 8.6.2.7
|
Parameter |
Unit |
Cell 1 |
Cell 2 |
Cell 3 |
UTRA RF Channel Number |
Mid Range Test Frequency |
Mid Range Test Frequency |
Mid Range Test Frequency |
||
PLMN |
PLMN 1 |
PLMN 2 |
PLMN 1 |
||
T0 |
CPICH Ec (FDD) |
dBm/3.84MHz |
-60 |
Off |
Off |
P-CCPCH RSCP (TDD) |
dBm |
-60 |
Off |
Off |
|
T1 |
CPICH Ec (FDD) |
dBm/3.84MHz |
-69 |
-60 |
Off |
P-CCPCH RSCP (TDD) |
dBm |
-69 |
-60 |
Off |
|
T2 |
CPICH Ec (FDD) |
dBm/3.84MHz |
Off |
-69 |
-60 |
P-CCPCH RSCP (TDD) |
dBm |
Off |
-69 |
-60 |
|
T3 |
CPICH Ec (FDD) |
dBm/3.84MHz |
Off |
Off |
Off |
P-CCPCH RSCP (TDD) |
dBm |
Off |
Off |
Off |
|
T4 |
CPICH Ec (FDD) |
dBm/3.84MHz |
Off |
Off |
-60 |
P-CCPCH RSCP (TDD) |
dBm |
Off |
Off |
-60 |
The UE is in CELL_DCH state of cell 1. SS transmits a LOGGING MEASUREMENT CONFIGURATION message to the UE to configure logged measurements.
SS transmits a PHYSICAL CHANNEL RECONFIGURATION message, which invokes the UE to transit from CELL_DCH to CELL_PCH.
The UE transmits a PHYSICAL CHANNEL RECONFIGURATION COMPLETE message and enters CELL_PCH state.
Wait 10s to allow UE to activate logging.
SS configures its downlink transmission power settings according to columns "T1" in table 8.6.2.7.
When the UE detects the presence of cell 2, it moves to CELL_FACH state and transmits a CELL UPDATE message without IE "Logged Meas Available".
Upon reception of CELL_UPDATE message, SS replies with a CELL UPDATE CONFIRM message, the IE "RRC State Indicator" set to "CELL_PCH".
Wait 10s to allow UE to activate logging.
SS configures its downlink transmission power settings according to columns "T2" in table 8.6.2.7.
When the UE detects the presence of cell 3, it moves to CELL_FACH state and transmits a CELL UPDATE message with IE "Logged Meas Available".
Upon reception of CELL_UPDATE message, SS replies with a CELL UPDATE CONFIRM message.
SS transmits an RRC CONNECTION RELEASE message to the UE to disconnect the connection.
The UE transmits an RRC CONNECTION RELEASE COMPLETE message using unacknowledged mode.
Wait 10s to allow UE to activate logging.
The UE transmits an RRC CONNECTION REQUEST message to SS.
SS transmits an RRC CONNECTION SETUP message to the UE.
The UE transmits an RRC CONNECTION SETUP COMPLETE message to SS, and enters CELL_DCH state.
SS transmits a UE INFORMATION REQUEST message, and the IE "Logged Measurements Report Request" is present.
The UE shall transmit a UE INFORMATION REPONSE message, with IE "Logged Meas Report" including logged report of Cell 1 and Cell 3.
SS transmits an RRC CONNECTION RELEASE message to the UE to disconnect the connection.
The UE transmits an RRC CONNECTION RELEASE COMPLETE message using unacknowledged mode
Wait 10s to allow UE to activate logging.
SS configures its downlink transmission power settings according to columns "T3" in table 8.6.2.7.
Wait 30s.
SS configures its downlink transmission power settings according to columns "T4" in table 8.6.2.7.
Wait 10s to allow UE to activate logging.
The UE transmits an RRC CONNECTION REQUEST message to SS.
SS transmits an RRC CONNECTION SETUP message to the UE.
The UE transmits an RRC CONNECTION SETUP COMPLETE message to SS, and enters CELL_DCH state.
SS transmits a UE INFORMATION REQUEST message, and the IE "Logged Measurements Report Request" is present.
The UE shall transmit a UE INFORMATION REPONSE message, with IE “Logged Meas Report” of Cell 2.
Expected Sequence
Step |
Direction |
Message |
Comment |
|
---|---|---|---|---|
UE |
SS |
|||
1 |
|
LOGGING MEASUREMENT CONFIGURATION |
Include IE “Logged Measurements Configuration Info”, with “Logging Interval” set as 2.56s and “Logging Duration” set as 10min. |
|
2 |
|
PHYSICAL CHANNEL RECONFIGURATION |
The IE "RRC state indicator" is set to "CELL_PCH". |
|
3 |
|
PHYSICAL CHANNEL RECONFIGURATION COMPLETE |
The UE sends this message before it completes state transition. |
|
4 |
Wait 10s to allow UE to activate logging. |
|||
5 |
SS configures its downlink transmission power settings according to columns "T1" in table 8.6.2.7. |
|||
6 |
|
CELL UPDATE |
The UE moves to CELL_FACH state and transmits this message without the IE "Logged Meas Available" on Cell 2. |
|
7 |
|
CELL UPDATE CONFIRM |
IE "RRC State Indicator" is set to "CELL_PCH". |
|
8 |
Wait 10s to allow UE to activate logging. |
|||
9 |
SS configures its downlink transmission power settings according to columns "T2" in table 8.6.2.7. |
|||
10 |
|
CELL UPDATE |
The UE moves to CELL_FACH state and transmits this message with the IE "Logged Meas Available" on Cell 3. |
|
11 |
|
CELL UPDATE CONFIRM |
IE "RRC State Indicator" is set to "CELL_DCH". |
|
12 |
|
RRC CONNECTION RELEASE |
||
13 |
|
RRC CONNECTION RELEASE COMPLETE |
The UE sends this message before it completes state transition. |
|
14 |
Wait 10s to allow UE to activate logging. |
|||
15 |
|
RRC CONNECTION REQUEST |
By outgoing call operation. |
|
16 |
|
RRC CONNECTION SETUP |
||
17 |
|
RRC CONNECTION SETUP COMPLETE |
||
17A |
–> |
RRC: INITIAL DIRECT TRANSFER NAS: SERVICE REQUEST |
The UE transmits SERVICE REQUEST message. |
|
– |
– |
– |
EXCEPTION: In parallel to the events described in steps 18 to 19 below, steps 6 to 13 defined in TS34.108 clause 7.2.4.2 occurs to complete service request procedure. |
|
18 |
|
UE INFORMATION REQUEST |
SS transmits a UE INFORMATION REQUEST message with IE "Logged Measurements Report Request" set to “true”. |
|
19 |
|
UE INFORMATION RESPONSE |
The UE shall send a UE INFORMATION RESPONSE message, with IE “Logged Meas Report” including logged report of Cell1 and Cell 3. |
|
19A |
|
RRC CONNECTION RELEASE |
||
19B |
|
RRC CONNECTION RELEASE COMPLETE |
||
20 |
Wait 10s to allow UE to activate logging. |
|||
21 |
SS configures its downlink transmission power settings according to columns "T3" in table 8.6.2.7. |
|||
22 |
Wait 30s to allow UE to activate logging. |
|||
23 |
SS configures its downlink transmission power settings according to columns "T4" in table 8.6.2.7. |
|||
24 |
Wait 10s to allow UE to activate logging. |
|||
25 |
|
RRC CONNECTION REQUEST |
By outgoing call operation. |
|
26 |
|
RRC CONNECTION SETUP |
||
27 |
|
RRC CONNECTION SETUP COMPLETE |
||
27A |
–> |
RRC: INITIAL DIRECT TRANSFER NAS: SERVICE REQUEST |
The UE transmits SERVICE REQUEST message. |
|
28 |
|
UE INFORMATION REQUEST |
SS transmits a UE INFORMATION REQUEST message with IE "Logged Measurements Report Request" set to “true”. |
|
29 |
|
UE INFORMATION RESPONSE |
The UE shall send a UE INFORMATION RESPONSE message, with IE “Logged Meas Report” including logged report of Cell 3. |
Specific Message Contents
All messages have the same content as defined in 34.108 clause 9 with the following exceptions:
LOGGING MEASUREMENT CONFIGURATION (Step 1)
Information Element |
Value/remark |
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Measurements Configuration Info |
|
– Absolute Time Info |
Set to value corresponding to the absolute time when the message is sent |
– Logging Duration |
10 min |
– Logging Interval |
|
– Trace reference |
|
– PLMN Identity |
Same as MIB |
– Trace ID |
‘0EF’H |
-Trace recording session |
‘1A’H |
– TCE Id |
‘5’H |
– CHOICE Area Configuration |
Not present |
CELL UPDATE (Step 6)
Use the message sub-type in default message content defined in 3GPP TS 34.108 [9] clause 9, with the following exceptions.
Information Element |
Value/remark |
Cell Update Cause |
‘Cell Re-selection’ |
Logged Meas Available |
Not present |
CELL UPDATE (Step 10)
Use the message sub-type in default message content defined in 3GPP TS 34.108 [9] clause 9, with the following exceptions.
Information Element |
Value/remark |
Cell Update Cause |
‘Cell Re-selection’ |
Logged Meas Available |
TRUE |
UE INFORMATION REQUEST (Steps 18 and 28)
Information Element |
Value/remark |
---|---|
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Measurements Report Request |
TRUE |
Logged ANR Report Request |
Not Present |
UE INFORMATION RESPONSE (FDD) (Step 19)
Information Element |
Value/remark |
---|---|
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Meas Report |
|
– Absolute Time Info |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace reference |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– PLMN Identity |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace ID |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace recording session |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– TCE Id |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– CHOICE mode |
FDD |
– List of measurements FDD |
At least one entry complies to entry with index ‘x’ below for cell 1 and at least one entry complies to entry with index ‘y’ below for cell 3. |
– Logged Measurement Info-FDD[x] |
|
– Relative Time Stamp[x] |
Not checked |
– Logged Measurements Serving Cell[x] |
|
– Cell ID |
Cell 1 |
– Primary CCPCH RSCP |
(0..91) |
– CPICH Ec/N0 |
(0..49) |
– Logged Measurement Info-FDD[y] |
|
– Relative Time Stamp[y] |
Not checked |
– Logged Measurements Serving Cell[y] |
|
– Cell ID |
Cell 3 |
– Primary CCPCH RSCP |
(0..91) |
– CPICH Ec/N0 |
(0..49) |
– Logged Meas Available |
Not checked |
UE INFORMATION RESPONSE (TDD) (Step 19)
Information Element |
Value/remark |
---|---|
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Meas Report |
|
– Absolute Time Info |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace reference |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– PLMN Identity |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace ID |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace recording session |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– TCE Id |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– CHOICE mode |
TDD |
– List of measurements TDD |
At least one entry complies to entry with index ‘x’ below for cell 1 and at least one entry complies to entry with index ‘y’ below for cell 3. |
– Logged Measurement Info-TDD[x] |
|
– Relative Time Stamp[x] |
Not checked |
– Logged Measurements Serving Cell[x] |
|
– Cell ID |
Cell 1 |
– Primary CCPCH RSCP |
(0..91) |
– Logged Measurement Info-TDD[y] |
|
– Relative Time Stamp[y] |
Not checked |
– Logged Measurements Serving Cell[y] |
|
– Cell ID |
Cell 3 |
– Primary CCPCH RSCP |
(0..91) |
– Logged Meas Available |
Not checked |
UE INFORMATION RESPONSE (FDD) (Step 29)
Information Element |
Value/remark |
---|---|
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Meas Report |
|
– Absolute Time Info |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace reference |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– PLMN Identity |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace ID |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace recording session |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– TCE Id |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– CHOICE mode |
FDD |
– List of measurements FDD |
At least one entry complies to entry with index ‘x’ below for cell 3 and the number of entries shall no more than 20/2.56. |
– Logged Measurement Info-FDD[x] |
|
– Relative Time Stamp[x] |
Not checked |
– Logged Measurements Serving Cell[x] |
|
– Cell ID |
Cell 3 |
– Primary CCPCH RSCP |
(0..91) |
– CPICH Ec/N0 |
(0..49) |
– Logged Meas Available |
Not checked |
UE INFORMATION RESPONSE (TDD) (Step 29)
Information Element |
Value/remark |
---|---|
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Meas Report |
|
– Absolute Time Info |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace reference |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– PLMN Identity |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace ID |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace recording session |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– TCE Id |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– CHOICE mode |
TDD |
– List of measurements TDD |
At least one entry complies to entry with index ‘x’ below for cell 3 and the number of entries shall no more than 20/2.56. |
– Logged Measurement Info-TDD[x] |
|
– Relative Time Stamp[x] |
Not checked |
– Logged Measurements Serving Cell[x] |
|
– Cell ID |
Cell 3 |
– Primary CCPCH RSCP |
(0..91) |
– Logged Meas Available |
Not checked |
8.6.2.7.5 Test requirement
At step 6, the UE shall transmit a CELL UPDATE message without the IE "Logged Meas Available" on Cell 2 (TP1).
At step 10, the UE shall transmit a CELL UPDATE message with the IE "Logged Meas Available" set as TRUE on Cell 3 (TP3).
At step 19, the UE shall transmit a UE INFORMATION RESPONSE message, with IE “Logged Meas Report” including logged report of Cell1 and Cell 3 (TP2).
At step 29, the UE shall transmit a UE INFORMATION RESPONSE message, with IE “Logged Meas Report” including logged report of Cell 3. And the number of entries in the List of measurements FDD or TDD shall be no more than the expected logged measurement result entries within 20 seconds of logging periods (TP4).
8.6.2.8 Logged MDT / Reporting / Location information
8.6.2.8.1 Definition
8.6.2.8.2 Conformance requirement
[TS 25.331, clause 8.5.65.2]
While T326 is running, the UE shall:
1> perform this logging in accordance with the following:
2> perform the logging while camping normally on an UTRA cell and the RPLMN of the UE is the same as the PLMN Identity stored in LOGGED_MEAS_REPORT_VARIABLE and, if the IE "Area Configuration" is present in variable LOGGED_MEAS_CONFIG, that is part of the concerned area;
2> perform the logging at regular intervals, as defined by the IE "Logging Interval" in variable LOGGED_MEAS_CONFIG;
2> when adding a logged measurement entry in variable LOGGED_MEAS_REPORT_VARIABLE, include the fields in accordance with the following:
3> set the IE "Relative Time Stamp" to indicate time relative to the moment at which the logged measurement configuration was received;
3> if GNSS location information became available during the last logging interval:
4> if the UE has been able to calculate a 3-dimensional position:
5> set IE "Ellipsoid point with altitude" to include the location coordinates;
4>else:
5> set IE "Ellipsoid point" to include the location coordinates:
3> set the IE "Cell ID" to indicate cell identity of the cell the UE is camping on obtained from system information;
3> set the IE "CPICH Ec/N0" and "CPICH RSCP" to include measured quantities of the cell that the UE is camping on for UTRA FDD;
3> set the "P-CCPCH RSCP" to include measured quantities for the cell that the UE is camping on for UTRA 1.28 Mcps TDD;
3> set the IE "Logged Measurements Intra Frequency Neighbouring Cells list", "Logged Measurements Inter Frequency list", "Logged Measurements E-UTRA frequency list", in order of decreasing ranking quantity as used for cell re-selection in each frequency for at most the following number of neighbouring cells; 6 intra-frequency and 3 inter-frequency neighbours per frequency as well as 3 inter-RAT neighbours, per frequency per RAT;
3> set the IE "Logged Measurements GSM Neighbouring Cells list" in order of decreasing RXLEV.
NOTE: The UE includes, only once, the latest available results of the measurement performed for cell reselection, which are performed in accordance with the regular performance requirements as specified in [19].
2> when the memory reserved for the logging of measurements becomes full, stop timer T326 and performs the same actions as performed upon expiry of T326, as specified in 8.5.63.4.
Reference
3GPP TS 25.331 clause 8.5.65.2.
8.6.2.8.3 Test Purpose
1. Verify presence of location information in Logged MDT measurement reports.
8.6.2.8.4 Method of test
Initial Condition
System Simulator: 2 cells, Cell 1 and Cell 2 are active.
UE: PS-DCCH+DTCH_DCH (state 6-10) in Cell 1 as specified in clause 7.4 of TS 34.108.
The UE’s positioning engine (e.g. standalone GNSS receiver) should be provided with any necessary stimulus to allow it to provide the position. This shall be done by use of the test function Update UE Location Information defined in TS 34.109 [10], if supported by the UE according to pc_UpdateUE_LocationInformation. Otherwise, or in addition any other suitable method may also be used.
Test Procedure
Same as the test procedure in subclause 8.2.6.1.4
Specific Message Contents
All messages have the same content as the specific messages in clause 8.2.6.1.4 with the following exceptions:
UE INFORMATION RESPONSE (FDD) (Step 12)
Information Element |
Value/remark |
---|---|
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Meas Report |
|
– Absolute Time Info |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace reference |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace recording session |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– TCE Id |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– CHOICE mode |
FDD |
– List of measurements FDD |
At least 1 entry where at least one entry complies to entry with index ‘x’ below. |
– Logged Measurement Info-FDD[x] |
|
– Relative Time Stamp[x] |
Checked to be present with a value bigger than 0. |
– Logged Measurements Serving Cell[x] |
|
– Cell ID[x] |
Cell 1 |
– Primary CCPCH RSCP[x] |
(0..91) |
– CPICH Ec/N0 |
(0..49) |
– Logged Measurements Intra Frequency list[x] |
Only 1 intra Frequency cell |
– Primary CPICH info |
Set to the scrambling code for cell 2 |
– CPICH RSCP |
(0..91) |
– CPICH Ec/N0 |
(0..49) |
– CHOICE GNSS UE Position |
Ellipsoid or Ellipsoid with altitude |
– Ellipsoid point |
If CHOICE GNSS UE Position is ’Ellipsoid’ then check to be present |
– Ellipsoid point with altitude |
If CHOICE GNSS UE Position is ’Ellipsoid with altitude’ then check to be present |
– Logged Meas Available |
Not checked |
UE INFORMATION RESPONSE (TDD) (Step 12)
Information Element |
Value/remark |
---|---|
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Meas Report |
|
– Absolute Time Info |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace reference |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace recording session |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– TCE Id |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– CHOICE mode |
TDD |
– List of measurements TDD |
At least 1 entry where at least one entry complies to entry with index ‘x’ below. |
– Logged Measurement Info-TDD[x] |
|
– Relative Time Stamp[x] |
Checked to be present with a value bigger than 0. |
– Logged Measurements Serving Cell[x] |
|
– Cell ID |
Cell 1 |
– Primary CCPCH RSCP |
(0..91) |
– Logged Measurements Intra Frequency list[x] |
Only 1 intra Frequency cell |
– Cell parameters Id |
Cell parameter Id of Cell 2 |
– Primary CCPCH RSCP |
(0..91) |
– CHOICE GNSS UE Position |
Ellipsoid or Ellipsoid with altitude |
– Ellipsoid point |
If CHOICE GNSS UE Position is ’Ellipsoid’ then check to be present |
– Ellipsoid point with altitude |
If CHOICE GNSS UE Position is ’Ellipsoid with altitude’ then check to be present |
– Logged Meas Available |
Not checked |
8.6.2.8.5 Test requirement
Test step numbers as per expected sequence table in subclause 8.6.2.1.4.
At step 12 the UE shall transmit a UE INFORMATION RESPONSE message includes IE “Logged Meas Report" with logged Measurements of Cell 2 in the “Logged Measurements Intra Frequency Neighbouring Cells list” with the IE Ellipsoid point or IE Ellipsoid point with altitude present (TP1).
8.6.2.9 Logged MDT / Logging and reporting / PLMN list / PLMN change
8.6.2.9.1 Definition
This test is applicable for all UEs that support Enhancement of Logged MDT services.
8.6.2.9.2 Conformance requirement
[TS 25.304, clause 5.7 (TP1, TP2)]
The UE may be configured to perform logging of measurement results in idle mode, CELL_PCH and URA_PCH state with LOGGING MEASUREMENT CONFIGURATION message specified in TS 25.331 [4]. This configuration is valid while the logging duration timer is running.
If the configuration of logged measurements is valid, the UE shall perform logging of measurement results if all of the following conditions are met:
– the UE is in camped normally state in idle mode, CELL_PCH or URA_PCH state;
– the RPLMN of the UE is present in the MDT PLMN identity list, if received in the LOGGING MEASUREMENT CONFIGURATION message, or the RPLMN of the UE is the same as the RPLMN at the point of time of LOGGING MEASUREMENT CONFIGURATION message reception
– the UE is camped on a cell belonging to Area Configuration (see TS 25.331 [4]), if configured;
– the UE is camped on the RAT where the logged measurement configuration was received.
Otherwise, the logging of measurement results shall be suspended.
NOTE: Even if logging of measurement results is suspended, the logging duration timer and time stamp will continue, and the logged measurement configuration and corresponding log are kept.
[TS 25.331, clause 8.1.3.6 (TP1, TP2)]
The UE shall compare the value of the IE "Initial UE identity" in the received RRC CONNECTION SETUP message with the value of the variable INITIAL_UE_IDENTITY.
If the values are different, the UE shall:
1> ignore the rest of the message.
If the values are identical, the UE shall:
…
1> submit an RRC CONNECTION SETUP COMPLETE message to the lower layers on the uplink DCCH after successful state transition per subclause 8.6.3.3, with the contents set as specified below:
…
2> if an IE "Logged Measurement Info-FDD" or "Logged Measurement Info-TDD" in variable LOGGED_MEAS_REPORT_VARIABLE is present and registered PLMN is present in the IE "PLMN Identity List" stored in variable LOGGED_MEAS_REPORT_VARIABLE:
3> include IE "Logged Meas Available".
…
When the RRC CONNECTION SETUP COMPLETE message has been submitted to lower layers for transmission the UE shall:
…
[TS 25.331, clause 8.5.65.2 (TP1, TP2)]
While T326 is running, the UE shall:
1> perform this logging in accordance with the following:
2> perform the logging while camping normally on an UTRA cell and the RPLMN of the UE is present in the "PLMN Identity List" stored in LOGGED_MEAS_REPORT_VARIABLE and, if the IE "Area Configuration" is present in variable LOGGED_MEAS_CONFIG, that is part of the concerned area;
2> perform the logging at regular intervals, as defined by the IE "Logging Interval” in variable LOGGED_MEAS_CONFIG;
2> when adding a logged measurement entry in variable LOGGED_MEAS_REPORT_VARIABLE, include the fields in accordance with the following:
3> set the IE "Relative Time Stamp" to indicate time relative to the moment at which the logged measurement configuration was received;
3> if GNSS location information became available during the last logging interval:
4> if the UE has been able to calculate a 3-dimensional position:
5> set IE "Ellipsoid point with altitude" or the IE "Ellipsoid point with altitude and uncertainty ellipsoid" to include the location coordinates;
4>else:
5> set IE "Ellipsoid point" or the IE "Ellipsoid point with uncertainty circle" or the IE "Ellipsoid point with uncertainty ellipse" to include the location coordinates:
4> a value of the IE "Confidence", different from "0" should be calculated, as the probability that the UE is located within the uncertainty region of the one of the IEs "Ellipsoid point with uncertainty ellipse" or "Ellipsoid point with altitude and uncertainty ellipsoid".
3> set the IE "PLMN Identity" of the Logged Measurements Serving Cell to indicate the PLMN Identity of the cell the UE is camping on obtained from system information;
3> set the IE "Cell ID" to indicate cell identity of the cell the UE is camping on obtained from system information;
3> set the IE "CPICH Ec/N0" and "CPICH RSCP" to include measured quantities of the cell that the UE is camping on for UTRA FDD;
3> set the "P-CCPCH RSCP" to include measured quantities for the cell that the UE is camping on for UTRA 1.28 Mcps TDD;
3> set the IE "Logged Measurements Intra Frequency Neighbouring Cells list", "Logged Measurements Inter Frequency list", "Logged Measurements E-UTRA frequency list", "Logged Measurements E-UTRA frequency extension list", in order of decreasing ranking quantity as used for cell re-selection in each frequency for at most the following number of neighbouring cells; 6 intra-frequency and 3 inter-frequency neighbours per frequency as well as 3 inter-RAT neighbours, per frequency per RAT;
3> set the IE "Logged Measurements GSM Neighbouring Cells list" in order of decreasing RXLEV.
NOTE: The UE includes, only once, the latest available results of the measurement performed for cell reselection, which are performed in accordance with the regular performance requirements as specified in [19].
2> when the memory reserved for the logging of measurements becomes full, stop timer T326 and performs the same actions as performed upon expiry of T326, as specified in 8.5.63.4.
Reference
TS 25.304 clause 5.7 and TS 25.331 clause 8.3.1.6, 8.5.65.2
.8.6.2.9.3 Test Purpose
1. Verify that IE "Logged Meas Available" is not indicated in the cell that does not belong to the PLMN included in LOGGING MEASUREMENT CONFIGURATION message.
2. Verify that IE "Logged Meas Available" is indicated in the cell that belongs to the PLMN included in LOGGING MEASUREMENT CONFIGURATION message.
8.6.2.9.4 Method of test
Initial conditions
System Simulator:
3 cells, cell 1, cell 2 and cell 3.
User Equipment:
UE: PS-DCCH+DTCH_DCH (state 6-10) in Cell 1 as specified in clause 7.4 of TS 34.108.
Test procedure
Table 8.6.2.9 illustrates the downlink power to be applied for the 3 cells. Column marked "T0" denotes the initial conditions, while columns marked "T1", "T2" are to be applied subsequently. The exact instants on which these values shall be applied are described in the text in this clause.
Table 8.6.2.9
Parameter |
Unit |
Cell 1 |
Cell 2 |
Cell 3 |
||||||
T0 |
T1 |
T2 |
T0 |
T1 |
T2 |
T0 |
T1 |
T2 |
||
UTRA RF Channel Number |
Mid Range Test Frequency |
Mid Range Test Frequency |
Mid Range Test Frequency |
|||||||
CPICH Ec (FDD) |
dBm/3.84 MHz |
-60 |
OFF |
OFF |
OFF |
-60 |
OFF |
OFF |
OFF |
-60 |
P-CCPCH RSCP(TDD) |
dBm |
-60 |
OFF |
OFF |
OFF |
-60 |
OFF |
OFF |
OFF |
-60 |
PLMN |
PLMN 1 |
PLMN 2 |
PLMN 3 |
a) SS transmits a LOGGING MEASUREMENT CONFIGURATION message with a cell list on Cell 1 and only Cell 3 in the configured cell list. SS changes Cell 1, Cell 2 and Cell 3 power levels, and the UE moves to idle mode on Cell 2.Verify Logging MDT measurements on Cell 2.
b) SS changes Cell 1, Cell 2 and Cell 3 power levels, and the UE moves to idle mode on Cell 3. Verify Logging MDT measurements on Cell 3.
Expected sequence
Step |
Direction |
Message |
Comments |
|
---|---|---|---|---|
UE |
SS |
|||
1 |
<– |
LOGGING MEASUREMENT CONFIGURATION |
SS transmits a LOGGING MEASUREMENT CONFIGURATION message with a cell list on Cell 1. Only Cell 3 in configured cell list. |
|
2 |
<– |
RRC CONNECTION RELEASE |
SS transmits a RRC CONNECTION RELEASE message to release the RRC connection. |
|
3 |
–> |
RRC CONNECTION RELEASE COMPLETE |
UE confirms the connection release and returns to Idle mode. |
|
4 |
– |
– |
Wait 10 seconds for UE logging interval timer to expire at least once |
|
5 |
– |
– |
SS changes Cell 1, Cell 2 and Cell 3 level according to the T1 in Table 8.6.2.9. |
|
6 |
– |
– |
UE select PLMN 2 and Cell2. Call PS Registration procdeure in TS34.108 clause 7.2.2.2.3 on cell 2, and enter idle mode. |
|
7 |
– |
– |
Wait 10 seconds for UE logging interval timer to expire at least once |
|
8 |
<– |
Paging |
SS transmits a Paging message. |
|
9 |
–> |
RRC CONNECTION REQUEST |
The UE transmits an RRC CONNECTION REQUEST message. |
|
10 |
<– |
RRC CONNECTION SETUP |
SS transmit an RRC CONNECTION SETUP message. |
|
11 |
–> |
RRC CONNECTION SETUP COMPLETE |
The UE shall transmit an RRC CONNECTION SETUP COMPLETE message with IE “Logged Meas Available” not present. |
|
12 |
<– |
RRC CONNECTION RELEASE |
SS transmits a RRC CONNECTION RELEASE message to release the RRC connection. |
|
13 |
–> |
RRC CONNECTION RELEASE COMPLETE |
The UE confirms the connection release and returns to Idle mode. |
|
14 |
– |
– |
SS changes Cell 1, Cell 2 and Cell 3 level according to the T2 in Table 8.6.2.9. |
|
15 |
– |
– |
UE select PLMN 3 and Cell3. Call PS Registration procdeure in TS34.108 clause 7.2.2.2.3 on cell 3, and enter idle mode. |
|
16 |
Wait 10 seconds for UE logging interval timer to expire at least once |
|||
17 |
<– |
Paging |
SS transmits a Paging message. |
|
18 |
–> |
RRC CONNECTION REQUEST |
The UE transmits an RRC CONNECTION REQUEST message. |
|
19 |
<– |
RRC CONNECTION SETUP |
SS transmit an RRC CONNECTION SETUP message. |
|
20 |
–> |
RRC CONNECTION SETUP COMPLETE |
The UE shall transmit an RRC CONNECTION SETUP COMPLETE message including IE “Logged Meas Available”. |
|
21 |
–> |
RRC: INITIAL DIRECT TRANSFER NAS: SERVICE REQUEST |
The UE transmits SERVICE REQUEST message. |
|
22 |
<– |
UE INFORMATION REQUEST |
SS send an UE INFORMATION REQUEST message to get logMeasReport. |
|
23 |
–> |
UE INFORMATION RESPONSE |
The UE shall send an UE INFORMATION RESPONSE message with Logged Meas Report of Cell 3. |
Specific message contents
All messages have the same content as defined in 34.108 clause 9 with the following exceptions:
LOGGING MEASUREMENT CONFIGURATION (Step 1)
Information Element |
Value/remark |
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Measurements Configuration Info |
|
– Absolute Time Info |
Set to value corresponding to the absolute time when the message is sent |
– Logging Duration |
10 min |
– Logging Interval |
2.56 |
– Trace reference |
|
– PLMN Identity |
Same as MIB |
– Trace ID |
‘0EF’H |
-Trace recording session |
‘1A’H |
– TCE Id |
‘5’H |
– CHOICE Area Configuration |
Not present |
– PLMN Identity List |
|
– PLMN Identity |
PLMN3 |
RRC CONNECTION SETUP COMPLETE (step 11)
Information Element |
Value/remark |
Message Type |
|
RRC transaction identifier |
The value of this IE is checked to see that it matches the value of the same IE transmitted in the downlink RRC CONNECTION SETUP message. |
Logged Meas Available |
Not present |
RRC CONNECTION SETUP COMPLETE (step 20)
Information Element |
Value/remark |
Message Type |
|
RRC transaction identifier |
The value of this IE is checked to see that it matches the value of the same IE transmitted in the downlink RRC CONNECTION SETUP message. |
Logged Meas Available |
True |
UE INFORMATION RESPONSE (FDD) (Step 23)
Information Element |
Value/remark |
---|---|
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Meas Report |
|
– Absolute Time Info |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace reference |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– PLMN Identity |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace ID |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace recording session |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– TCE Id |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– CHOICE mode |
FDD |
– List of measurements FDD |
At least 2 entry where at least one entry complies to entry with index ‘x’ and at least one entry with index ’y’ below. |
– Logged Measurement Info-FDD[x] |
|
– Relative Time Stamp[x] |
Not checked |
– Logged Measurements Serving Cell[x] |
|
– PLMN Identity |
PLMN1 |
– Cell ID |
Cell 1 |
– Primary CCPCH RSCP |
(0..91) |
– CPICH Ec/N0 |
(0..49) |
– Logged Measurement Info-FDD[y] |
|
– Relative Time Stamp[y] |
Not checked |
– Logged Measurements Serving Cell[y] |
|
– PLMN Identity[y] |
PLMN3 |
– Cell ID |
Cell 3 |
– Primary CCPCH RSCP |
(0..91) |
– CPICH Ec/N0 |
(0..49) |
– Logged Meas Available |
Not checked |
UE INFORMATION RESPONSE (TDD) (Step 23)
Information Element |
Value/remark |
---|---|
Message Type |
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Integrity check info |
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
Logged Meas Report |
|
– Absolute Time Info |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace reference |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace recording session |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– PLMN Identity |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– Trace ID |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– TCE Id |
Same value as sent by SS in LOGGING MEASUREMENT CONFIGURATION in step 1 |
– CHOICE mode |
TDD |
– List of measurements TDD |
At least 2 entry where at least one entry complies to entry with index ‘x’ and at least one entry with index ’y’ below. |
– Logged Measurement Info-TDD[x] |
|
– Relative Time Stamp[x] |
Not checked |
– Logged Measurements Serving Cell[x] |
|
– PLMN Identity |
PLMN1 |
– Cell ID |
Cell 1 |
– Primary CCPCH RSCP |
(0..91) |
– Logged Measurement Info-TDD[y] |
|
– Relative Time Stamp[y] |
Not checked |
– Logged Measurements Serving Cell[y] |
|
– PLMN Identity |
PLMN3 |
– Cell ID |
Cell 3 |
– Primary CCPCH RSCP |
(0..91) |
– Logged Meas Available |
Not checked |
8.6.2.9.5 Test requirements
At step 11, the UE shall transmit an RRC CONNECTION SETUP COMPLETE message with IE “Logged Meas Available” not present (TP1).
At step 20, the UE shall transmit an RRC CONNECTION SETUP COMPLETE message including IE “Logged Meas Available” (TP2).
At step 23, the UE shall send an UE INFORMATION RESPONSE message with Logged Meas Report of Cell 1 and Cell 3(TP2).