8.4.1 Measurement Control and Report

34.123-13GPPPart 1: Protocol conformance specificationRelease 15TSUser Equipment (UE) conformance specification

8.4.1.1 Measurement Control and Report: Intra-frequency measurement for transition from idle mode to CELL_DCH state (FDD)

8.4.1.1.1 Definition

8.4.1.1.2 Conformance requirement

Upon transition from idle mode to CELL_DCH state:

1> if intra-frequency measurements applicable to CELL_DCH state are stored in the variable MEASUREMENT_IDENTITY:

2> if the cell in which the UE transited from idle mode is included in the active set for the CELL_DCH state, the UE shall:

3> begin measurement reporting.

2> otherwise:

3> the UE should not begin the measurement reporting. If the UE does not begin the measurement reporting, the measurement shall be restarted when a MEASUREMENT CONTROL message is received with the corresponding measurement identity.

In CELL_DCH state, the UE shall:

1> transmit a MEASUREMENT REPORT message on the uplink DCCH when the reporting criteria stored in variable MEASUREMENT_IDENTITY are met for any ongoing measurements that are being performed in the UE.

The reporting criteria are fulfilled if either:

– a periodic MEASUREMENT REPORT message shall be sent according to the IE "Periodical Reporting Criteria"; or

– an event in stored IE "Measurement reporting criteria" was triggered. Events and triggering of reports for different measurement types are described in detail in clause 14.

For the measurement, which triggered the MEASUREMENT REPORT message, the UE shall:

1> set the IE "measurement identity" to the measurement identity, which is associated with that measurement in variable MEASUREMENT_IDENTITY;

1> set the IE "measured results" to include measurements according to the IE "reporting quantity" of that measurement stored in variable MEASUREMENT_IDENTITY; and

2> if all the reporting quantities are set to "false":

3> not set the IE "measured results".

1> set the IE "Measured results" in the IE "Additional measured results" according to the IE "reporting quantity" for all measurements associated with the measurement identities included in the "Additional measurements list" stored in variable MEASUREMENT_IDENTITY of the measurement that triggered the measurement report; and

2> if one or more additional measured results are to be included:

3> include only the available additional measured results, and sort them in ascending order according to their IE "measurement identity" in the MEASUREMENT REPORT message.

1> if the MEASUREMENT REPORT message was triggered by an event (i.e. not a periodical report):

The UE shall:

1> transmit the MEASUREMENT REPORT message on the uplink DCCH using either AM or UM RLC according to the stored IE "measurement reporting mode" associated with the measurement identity that triggered the report.

When the MEASUREMENT REPORT message has been submitted to lower layers for transmission:

1> the procedure ends.

Upon reception of a MEASUREMENT CONTROL message the UE shall perform actions specified in TS 25.331 subclause 8.6 unless otherwise specified below.

The UE shall:

1> read the IE "Measurement command";

1> if the IE "Measurement command" has the value "setup":

2> store this measurement in the variable MEASUREMENT_IDENTITY according to the IE "measurement identity", first releasing any previously stored measurement with that identity if that exists;

….

2> for measurement types "inter-RAT measurement" or "inter-frequency measurement":

2> for measurement type "UE positioning measurement":

2> for any other measurement type:

3> if the measurement is valid in the current RRC state of the UE:

4> begin measurements according to the stored control information for this measurement identity.

1> if the IE "Measurement command" has the value "modify":

2> for all IEs present in the MEASUREMENT CONTROL message:

3> if a measurement was stored in the variable MEASUREMENT_IDENTITY associated to the identity by the IE "measurement identity":

4> if the measurement type is quality, UE internal, intra-frequency, inter-frequency or inter-RAT:

5> if the UE is in CELL_FACH state:

6> the UE behaviour is not specified.

4> if measurement type is set to "intra-frequency measurement", for any of the optional IEs "Intra-frequency measurement objects list", "Intra-frequency measurement quantity", "Intra-frequency reporting quantity", "Measurement Validity", "report criteria" and "parameters required for each event" (given "report criteria" is set to "intra-frequency measurement reporting criteria") that are present in the MEASUREMENT CONTROL message:

2> for any other measurement type:

3> resume the measurements according to the new stored measurement control information.

1> if the IE "measurement command" has the value "release":

2> terminate the measurement associated with the identity given in the IE "measurement identity";

2> clear all stored measurement control information related associated to this measurement identity in variable MEASUREMENT_IDENTITY.

If the IE "Reporting Cell Status" is not received for intra-frequency, inter-frequency measurement, or inter-RAT measurement, the UE shall:

1> for intra-frequency measurement, inter-frequency measurement and inter-RAT measurement:

2> exclude the IE "Measured Results" in MEASUREMENT REPORT.

NOTE: The IE "Reporting Cell Status" within "Event Criteria List" defines whether "Cell Measured Results" is present for event-based reporting.

The IE "Reporting Cell Status" is not included in System Information Block 11/12 for periodic intra-frequency measurements. In this case the UE shall assume the default values "Report cells within active set and/or monitored set on used frequency" and "6".Reference

3GPP TS 25.331 clause 8.4.1.8.1, 8.4.1.3, 8.4.2.2, 8.6.7.9.

8.4.1.1.3 Test Purpose

1. To confirm that the UE continues to monitor intra-frequency measurement quantity of the cells listed in System Information Block type 11 or 12 messages, after it has entered CELL_DCH state from idle mode. When the intra-frequency measurement reporting criteria specified in System Information Block type 11 or 12 messages have been met, it shall report the measurements using MEASUREMENT REPORT message(s).

2. To confirm that the UE terminates monitoring and reporting activities for the cells listed in "intra-frequency cell info list" IE in System Information Block type 11 or 12 messages, after it has received a MEASUREMENT CONTROL message that specifies the measurement type to be "intra-frequency measurement" with the same measurement identity as in System Information Block Type 11 or 12 messages. To confirm that the UE reconfigures the monitoring and reporting activities based on the last MEASUREMENT CONTROL message received.

8.4.1.1.4 Method of test

Initial Condition

System Simulator: 3 cells – Cell 1, Cell 2 and Cell 3 are active.

UE: "Registered idle mode on CS" (state 2) or "Registered idle mode on PS" (state 3) in cell 1 as specified in clause 7.4 of TS 34.108, depending on the CN domain supported by the UE If the UE supports both CS and PS domains, the initial UE state shall be "Registered idle mode on CS/PS" (state 7).

Test Procedure

Table 8.4.1.1-1 illustrates the downlink power to be applied for the 3 cells at various time instants of the test execution. Column marked "T0" denotes the initial conditions, while columns marked "T1" and "T2" are to be applied subsequently. The exact instants on which these values shall be applied are described in the texts in this clause.

Table 8.4.1.1-1

Parameter

Unit

Cell 1

Cell 2

Cell 3

T0

T1

T2

T0

T1

T2

T0

T1

T2

UTRA RF Channel Number

Mid Range Test Frequency

Mid Range Test Frequency

Mid Range Test Frequency

CPICH Ec

dBm/3.84 MHz

-60

-60

-60

-70

-60

-75

-80

-60

-60

The UE is initially in idle mode and has selected cell 1 for camping. The System Information Block type 11 messages are modified with respect to the default settings. The key measurement parameters in the modified System Information Block message are as follow: report criteria = "periodic reporting criteria", reporting interval = "64 seconds".

SS prompts the operator to make an outgoing call of a supported traffic class. SS and UE shall execute procedure P3 (for CS service) or P5 (for PS service). Next SS and UE shall execute procedure P7 (for CS service) or P9 (for PS service). Then SS and UE shall execute procedure P11 (for CS service) or P13 (for PS service). The UE shall send a MEASUREMENT REPORT message after reaching CELL_DCH state, reporting cell 2’s CPICH RSCP value. After 64 seconds has passed since SS receives the first MEASUREMENT REPORT message, the UE shall transmit a second MEASUREMENT REPORT message.

NOTE: In P11 or P13 in step 4, in RADIO BEARER SETUP message, IE "Default DPCH Offset Value" and IE "DPCH frame offset" are set to "0".

SS sends a MEASUREMENT CONTROL message on the downlink DCCH. In this message, SS configures an intra-frequency measurement based on the measurement quantity CPICH RSCP. Parameters used in this message are: measurement identity = "1", report criteria = "event-trigger", event identity = "1e", reporting threshold = "-70 dBm". SS checks to see that no MEASUREMENT REPORT messages are sent within the next 64 seconds (which is due to periodic reporting). SS reconfigures the downlink transmission power settings according to values in column "T1" in table 8.4.1.1-1. The UE shall transmit a MEASUREMENT REPORT message when it detects that the CPICH RSCP of cell 3 has risen above the threshold value specified in the previous MEASUREMENT CONTROL message.

SS sends then a new MEASUREMENT CONTROL message to add cell 2 to the list of the cells the UE shall measure. Since the RSCP for cell 2 is above the threshold for event 1e to be triggered, a MEASUREMENT REPORT triggered by cell 2 shall be sent by the UE.

SS reconfigures the downlink transmission power settings according to values in column "T2" in table 8.4.1.1-1. SS sends a new MEASUREMENT CONTROL message on the downlink DCCH. In this message, SS configures an intra-frequency measurement based on the measurement quantity CPICH RSCP. Parameters used in this message are:

measurement identity = "1", report criteria = "event-trigger", event identity = "1a", Reporting range 8db. SS reconfigures the downlink transmission power settings according to values in column "T1" in table 8.4.1.1-1. The UE shall transmit a MEASUREMENT REPORT message when it detects that the condition for event 1a is fulfilled. SS calls for generic procedure C.3 to check that UE is in CELL_DCH state.

Expected Sequence

Step

Direction

Message

Comment

UE

SS

1

System Information Block type 11

The UE is in idle mode and camped onto cell 1. The System Information Block type 11 messages to be transmitted are different from the default settings (see specific message contents)

2

SS executes procedure P3 (clause 7.4.2.1.2) or P5 (clause 7.4.2.2.2) specified in TS 34.108.

3

SS executes procedure P7 (clause 7.4.2.3.2) or P9 (clause 7.4.2.4.2) specified in TS 34.108.

4

SS executes procedure P11 (clause 7.4.2.5.2) or P13 (clause 7.4.2.6.2) specified in TS 34.108.

IE "Default DPCH Offset Value" and IE "DPCH frame offset" in RADIO BEARER SETUP message is set to "0".

5

SS

SS shall wait for a MEASUREMENT REPORT message. This MEASUREMENT REPORT shall be received on or before 64 Seconds.

6

MEASUREMENT REPORT

After receiving this message, SS shall expect to receive the next MEASUREMENT REPORT message after 64 seconds.

6a

MEASUREMENT REPORT

7

MEASUREMENT CONTROL

A measurement with "measurement identity" IE set to "1" is assigned, with the IE "CHOICE reporting criteria" set to "intra-frequency measurement reporting criteria". See specific message content for the rest of the message.

8

SS waits for 64 seconds and verifies that no further MEASUREMENT REPORT messages are detected on the uplink DCCH.

9

SS re-adjusts the downlink transmission power settings according to columns "T1" in table 8.4.1.1-1.

10

MEASUREMENT REPORT

SS verifies that UE transmits a MEASUREMENT REPORT message triggered by cell 3 and containing report the measured CPICH RSCP value of cell 3.

10a

MEASUREMENT CONTROL

A MEASUREMENT CONTROL is sent to the UE to modify the list of the cells the UE shall monitor.

10b

MEASUREMENT REPORT

SS verifies that UE transmits a MEASUREMENT REPORT message triggered by cell 2.

11

SS re-adjusts the downlink transmission power settings according to columns "T2" in table 8.4.1.1-2.

12

MEASUREMENT CONTROL

A measurement with "measurement identity" IE set to "1" is assigned, with the IE "CHOICE reporting criteria" set to "intra-frequency measurement reporting criteria". See specific message content for the rest of the message.

13

SS re-adjusts the downlink transmission power settings according to columns "T1" in table 8.4.1.1-3 and waits 5 seconds.

14

MEASUREMENT REPORT

SS verifies that UE transmits a MEASUREMENT REPORT message to report occurrence of event 1a.

15



CALL C.3

If the test result of C.3 indicates that UE is in CELL_DCH state, the test passes, otherwise it fails.

Specific Message Contents

All messages indicated below shall use the same content as described in default message content, with the following exceptions:

System Information Block type 11 (Step 1)

Use the same System Information Block Type 11 message as found in clause 6.1.0b of TS 34.108, with the following exceptions:

Information Element

Value/remark

Measurement control system information

– Intra-frequency measurement system information

– Intra-frequency measurement identity

Not Present

Absence of this IE is equivalent to default value 1

– Intra-frequency cell info list

– CHOICE intra-frequency cell removal

Not present

(This IE shall be ignored by the UE for SIB11)

– New intra-frequency cells

– Intra-frequency cell id

1

– Cell info

– Cell individual offset

Not present

Absence of this IE is equivalent to default value 0 dB

– Reference time difference to cell

Not Present

– Read SFN Indicator

TRUE

– CHOICE Mode

FDD

– Primary CPICH Info

– Primary Scrambling Code

Refer to clause titled "Default settings for cell No.1 (FDD)" in clause 6.1.4 of TS 34.108

– Primary CPICH TX power

Not Present

– TX Diversity Indicator

FALSE

– Cell selection and Re-selection

Not Present (The IE shall be absent as this is the serving cell)

– Intra-frequency cell id

2

– Cell info

– Cell individual offset

Not present

Absence of this IE is equivalent to default value 0dB

– Reference time difference to cell

1024

– Read SFN Indicator

TRUE

– CHOICE Mode

FDD

– Primary CPICH Info

– Primary Scrambling Code

Refer to clause titled "Default settings for cell No.2 (FDD)" in clause 6.1.4 of TS 34.108

– Primary CPICH TX power

Not Present

– TX Diversity Indicator

FALSE

– Cell selection and Re-selection info

Not present

For neighbouring cell, if HCS is not used and all the parameters in cell selection and re-selection info are Default value, this IE is absent.

– Reporting information for state CELL_DCH

– Intra-frequency reporting quantity

– Reporting quantities for active set cells

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CHOICE mode

FDD

– CPICH Ec/No reporting indicator

FALSE

– CPICH RSCP reporting indicator

FALSE

– Pathloss reporting indicator

FALSE

– Reporting quantities for monitored set cells

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CHOICE mode

FDD

– CPICH Ec/No reporting indicator

FALSE

– CPICH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Measurement Reporting Mode

– Measurement Report Transfer Mode

Acknowledged mode RLC

– Periodical Reporting / Event Trigger Reporting Mode

Periodical reporting

– CHOICE report criteria

Periodic reporting criteria

– Amount of reporting

Infinity

– Reporting interval

64 seconds

MEASUREMENT REPORT (Step 6 and 6a)

NOTE 1: The Cell measured results for Cell 1 may or may not be present.

Information Element

Value/remark

Measurement identity

Check to see if set to 1

Measured Results

– CHOICE measurement

Check to see if set to "Intra-frequency measured results list"

– Intra-frequency measurement results

– Cell measured results

See Note 1

– Cell Identity

Check to see if it is absent

– Cell synchronisation information

Check to see if this IE is absent

– Primary CPICH Info

– Primary Scrambling Code

Check to see if it’s the same code for cell 1 (if present)

– CPICH Ec/No

Check to see if this IE is absent

– CPICH RSCP

Check to see if this IE is absent

– Pathloss

Check to see if this IE is absent

– Cell Identity

Check to see if it is absent

– Cell synchronisation information

Check to see if this IE is absent

– Primary CPICH Info

– Primary Scrambling Code

Check to see if it’s the same code for cell 2

– CPICH Ec/No

Check to see if this IE is absent

– CPICH RSCP

"Checked to see if set to within an acceptable range"

– Pathloss

Check to see if this IE is absent

Measured Results on RACH

Check to see if this IE is absent

Additional Measured results

Check to see if this IE is absent

Event Results

Check to see if this IE is absent

MEASUREMENT CONTROL (Step 7)

Information Element

Value/remark

Measurement Identity

1

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Event Trigger

Additional measurements list

Not Present

CHOICE measurement type

Intra-frequency measurement

– Intra Frequency Cell Info List

– CHOICE intra-frequency cell removal

Remove all intra-frequency cells

– New intra-frequency cells

2 new intra-frequency cells

– Intra-frequency cell id

1

– Cell info

– Cell individual offset

0 dB

– Reference time difference to cell

Not Present

– Read SFN Indicator

FALSE

– CHOICE mode

FDD

– Primary CPICH Info

– Primary Scrambling Code

Set to same code as used for cell 1

– Primary CPICH TX power

Not Present

– TX Diversity Indicator

FALSE

– Intra-frequency cell id

3

– Cell info

– Cell individual offset

0 dB

– Reference time difference to cell

256 chips

– Read SFN Indicator

TRUE

– CHOICE mode

FDD

– Primary CPICH Info

– Primary Scrambling Code

Set to same code as used for cell 3

– Primary CPICH TX power

Not Present

– TX Diversity Indicator

FALSE

– Cell for measurement

Not Present

– Intra-frequency measurement quantity

– Filter Coefficient

Not Present (Default is 0)

– CHOICE Mode

FDD

– Measurement quantity

CPICH RSCP

– Intra-frequency reporting quantity

– Reporting quantities for active set cells

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CHOICE mode

FDD

– CPICH Ec/No reporting indicator

TRUE

– CPICH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting quantities for monitored set cells

– Cell synchronisation information reporting indicator

TRUE

– Cell identity reporting indicator

FALSE

– CHOICE mode

FDD

– CPICH Ec/No reporting indicator

FALSE

– CPICH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting quantities for detected cells

Not present

– Reporting cell status

Not Present

– Measurement validity

Not present

– CHOICE report criteria

Intra-frequency measurement reporting criteria

– Parameters required for each events

– Intra-frequency event identity

1e

– Triggering condition 1

Not present

– Triggering condition 2

Monitored set cells

– Hysteresis

2 (1 dB)

– Threshold used frequency

-70 dBm

– Time to trigger

0 ms

– Reporting cell status

– CHOICE reported cell

Report cells within active and/or monitored set on used frequency or within active and/or monitored set on non-used frequency

– Maximum number of reported cells

3

DPCH compressed mode status info

Not Present

MEASUREMENT REPORT (Step 10)

NOTE 1: Cell measured results for cells 1 and 3 may appear in either order (i.e. cell 1 then cell 3 or cell 3 then cell 1).

Information Element

Value/remark

Measurement identity

Check to see if set to 1

Measured Results

– CHOICE measurement

Check to see if set to "Intra-frequency measured results list"

– Intra-frequency measurement results

– Cell measured results

See Note 1

– Cell Identity

Check to see if it is absent

– Cell synchronisation information

Check to see if it is absent.

– Primary CPICH Info

– Primary Scrambling Code

Check to see if it’s the same code for cell 1

– CPICH Ec/No

Check to see if this IE is present

– CPICH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

– Cell measured results

See Note 1

– Cell Identity

Check to see if it is absent

– Cell synchronisation information

Check to see if this IE is present and that the COUNT-C-SFN frame difference is included in it.

– Primary CPICH Info

– Primary Scrambling Code

Check to see if it’s the same code for cell 3

– CPICH Ec/No

Check to see if this IE is absent

– CPICH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

Measured Results on RACH

Check to see if this IE is absent

Additional Measured Results

Check to see if this IE is absent

Event Results

– CHOICE event result

Check to see if this IE is set to "Intra-frequency measurement event results"

– Intra-frequency event identity

Check to see if this IE is set to "1e"

– Cell measured event results

– CHOICE mode

Check to see if this IE is set to "FDD"

– Primary CPICH info

– Primary Scrambling Code

Check to see if it’s the same code for cell 3

MEASUREMENT CONTROL (Step 10a)

Information Element

Value/remark

Measurement Identity

1

Measurement Command

Modify

Measurement Reporting Mode

Not Present

Additional measurements list

Not Present

CHOICE measurement type

Intra-frequency measurement

– Intra-frequency cell info list

– CHOICE intra-frequency cell removal

Remove no intra-frequency cells

– New intra-frequency info list

1 new intra-frequency cell

– Intra-frequency cell id

2

– Cell info

– Cell individual offset

0 dB

– Reference time difference to cell

0

– Read SFN Indicator

FALSE

– CHOICE mode

FDD

– Primary CPICH Info

– Primary Scrambling Code

Set to same code as used for cell 2

– Primary CPICH TX power

Not Present

– TX Diversity Indicator

FALSE

– Cell for measurement

Not Present

– Intra-frequency measurement quantity

Not Present

– Intra-frequency reporting quantity

Not Present

– Reporting cell status

Not Present

– Measurement validity

Not Present

– CHOICE report criteria

Not Present

MEASUREMENT REPORT (Step 10b)

Information Element

Value/remark

Measurement identity

Check to see if set to 1

Measured Results

– CHOICE measurement

Check to see if set to "Intra-frequency measured results list"

– Intra-frequency measurement results

Check to see if measurement results for 3 cells are included (the order in which the different cells are reported is not important)

– Cell measured results

(for cell 1)

– Cell Identity

Check to see if it is absent

– Cell synchronisation information

Check to see if it is absent.

– Primary CPICH Info

– Primary Scrambling Code

Check to see if it’s the same code for cell 1

– CPICH Ec/No

Check to see if this IE is present

– CPICH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

– Cell measured results

(for cell 2)

– Cell Identity

Check to see if it is absent

– Cell synchronisation information

Check to see if this IE is present and that the COUNT-C-SFN frame difference may or may not be included in it.

– Primary CPICH Info

– Primary Scrambling Code

Check to see if it’s the same code for cell 2

– CPICH Ec/No

Check to see if this IE is absent

– CPICH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

– Cell measured results

(for cell 3)

– Cell Identity

Check to see if it is absent

– Cell synchronisation information

Check to see if this IE is present and that the COUNT-C-SFN frame difference is included in it.

– Primary CPICH Info

– Primary Scrambling Code

Check to see if it’s the same code for cell 3

– CPICH Ec/No

Check to see if this IE is absent

– CPICH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

Measured Results on RACH

Check to see if this IE is absent

Additional Measured Results

Check to see if this IE is absent

Event Results

– CHOICE event result

Check to see if this IE is set to "Intra-frequency measurement event results"

– Intra-frequency event identity

Check to see if this IE is set to "1e"

– Cell measured event results

– CHOICE mode

Check to see if this IE is set to "FDD"

– Primary CPICH info

– Primary Scrambling Code

Check to see if it’s the same code for cell 2

MEASUREMENT CONTROL (Step 12)

Information Element

Value/remark

Measurement Identity

1

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Event Trigger

Additional measurements list

Not Present

CHOICE measurement type

Intra-frequency measurement

– Intra-frequency cell info list

– CHOICE intra-frequency cell removal

Remove all intra-frequency cells

– New intra-frequency cells

2 new intra-frequency cells

– Intra-frequency cell id

1

– Cell info

– Cell individual offset

0 dB

– Reference time difference to cell

Not Present

– Read SFN Indicator

FALSE

– CHOICE mode

FDD

– Primary CPICH Info

– Primary Scrambling Code

Set to same code as used for cell 1

– Primary CPICH TX power

Not Present

– TX Diversity Indicator

FALSE

– Intra-frequency cell id

2

– Cell info

– Cell individual offset

0 dB

– Reference time difference to cell

0 chips

– Read SFN Indicator

FALSE

– CHOICE mode

FDD

– Primary CPICH Info

– Primary Scrambling Code

Set to same code as used for cell 2

– Primary CPICH TX power

Not Present

– TX Diversity Indicator

FALSE

– Cells for measurement

Not Present

– Intra-frequency measurement quantity

– Filter Coefficient

Not Present (Default is 0)

– Measurement quantity

CPICH RSCP

– Intra-frequency reporting quantity

– Reporting quantities for active set cells

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CPICH Ec/No reporting indicator

FALSE

– CPICH RSCP reporting indicator

FALSE

– Pathloss reporting indicator

FALSE

– Reporting quantities for monitored set cells

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CPICH Ec/No reporting indicator

FALSE

– CPICH RSCP reporting indicator

FALSE

– Pathloss reporting indicator

FALSE

– Reporting quantities for detected cells

Not present

– Reporting cell status

Not Present

– Measurement validity

Not present

– CHOICE report criteria

Intra-frequency measurement reporting criteria

– Parameters required for each events

– Intra-frequency event identity

1a

– Triggering condition 1

Not present

– Triggering condition 2

Monitored set cells

– Reporting range constant

16 (8 dB)

– Cells forbidden to affect reporting range

Not Present

– W

0

– Hysteresis

0 (0 dB)

– Threshold used frequency

Not Present

– Reporting deactivation threshold

1

– Replacement activation threshold

Not Present

– Time to trigger

5000 msec

– Amount of reporting

Infinity

– Reporting interval

16 s

– Reporting cell status

Not Present

DPCH compressed mode status info

Not Present

MEASUREMENT REPORT (Step 14)

Information Element

Value/remark

Measurement identity

Check to see if set to 1

Measured Results

Check to see if this IE is absent

Measured Results on RACH

Check to see if this IE is absent

Additional Measured Results

Check to see if this IE is absent

Event Results

– CHOICE event result

– Intra-frequency event identity

Check to see if this IE is set to "1a"

– Cell measured event results

– CHOICE mode

Check to see if this IE is set to "FDD"

– Primary CPICH info

– Primary Scrambling Code

Check to see if it’s the same code for cell 2

8.4.1.1.5 Test Requirement

After step 5 the UE shall start to transmit 2 MEASUREMENT REPORT messages at 64 seconds interval. The measurement quantity "CPICH RSCP" of cell 2 shall be reported in these messages.

After step 7 the UE shall not transmit any MEASUREMENT REPORT messages within 64 seconds after SS has transmitted the MEASUREMENT CONTROL message in step 7.

After step 9 the UE shall transmit a MEASUREMENT REPORT message on the uplink DCCH, to report that the CPICH RSCP value for cell 3 has risen above the threshold stated in the MEASUREMENT CONTROL message transmitted by the SS in step 7. This MEASUREMENT REPORT message shall also contain IE "Event results", indicating the triggering of event ‘1e’ by cell 3. It shall also contain the measured CPICH RSCP value and cell synchronisation information for cell 3, and the measured CPICH Ec/No and RSCP values for cell 1.

After step 10a, the UE shall transmit a MEASUREMENT REPORT message on the uplink DCCH to report that the CPICH RSCP value for cell 2 has risen above the threshold stated in the MEASUREMENT CONTROL message transmitted by the SS in step 10a. The MEASUREMENT REPORT message shall contain the measured CPICH RSCP value and cell synchronisation information for cell 2 and cell 3, as well as the measured CPICH Ec/No and RSCP for cell 1. The IE "Event results" in this message shall indicate that cell 2 has triggered the event.

After step 13, the UE shall transmit a MEASUREMENT REPORT message containing IE "Event results", indicating the triggering of event ‘1a’ by cell 2. The MEASUREMENT REPORT message shall not contain any measured results.

8.4.1.1a Measurement Control and Report: Intra-frequency measurement for transition from idle mode to CELL_DCH state (TDD)

8.4.1.1a.1 Definition

8.4.1.1a.2 Conformance requirement

The UE shall obey the following rules for different measurement types after transiting from idle mode to CELL_DCH state:

Upon transition from idle mode to CELL_DCH state, the UE shall:

1> if intra-frequency measurements applicable to CELL_DCH state are stored in the variable MEASUREMENT_IDENTITY:

2> begin measurement reporting.

Upon reception of a MEASUREMENT CONTROL message the UE shall perform actions specified in subclause 8.6 in TS 25.331 unless otherwise specified below.

The UE shall:

1> read the IE "Measurement command";

1> if the IE "Measurement command" has the value "setup":

2> store this measurement in the variable MEASUREMENT_IDENTITY according to the IE "measurement identity", first releasing any previously stored measurement with that identity if that exists;

2> if the measurement type is quality, UE internal, intra-frequency, inter-frequency or inter-RAT:

3> if, according to its measurement capabilities, the UE does not require compressed mode to perform the measurements:

4> if the measurement is valid in the current RRC state of the UE:

5> begin measurements according to the stored control information for this measurement identity.

2> for any other measurement type:

3> if the measurement is valid in the current RRC state of the UE:

4> begin measurements according to the stored control information for this measurement identity.

1> if the IE "measurement command" has the value "release":

2> terminate the measurement associated with the identity given in the IE "measurement identity";

2> clear all stored measurement control information related associated to this measurement identity in variable MEASUREMENT_IDENTITY.

1> clear the entry for the MEASUREMENT CONTROL message in the table "Accepted transactions" in the variable TRANSACTIONS;

1> if the UE "Additional Measurement List" is present:

2> if the received measurement configuration in this MEASUREMENT CONTROL message or any measurement identities in the "Additional Measurement List" do not all have the same validity:

3> set the variable CONFIGURATION_INCOMPLETE to TRUE.

1> and the procedure ends.

The purpose of the measurement reporting procedure is to transfer measurement results from the UE to UTRAN.

In CELL_DCH state, the UE shall:

  1. transmit a MEASUREMENT REPORT message on the uplink DCCH when the reporting criteria stored in variable MEASUREMENT_IDENTITY are met for any ongoing measurements that are being performed in the UE.

The reporting criteria are fulfilled if either:

– the first measurement has been completed according to the requirements set in [19] or [20] for a newly initiated measurement with periodic reporting; or

– the time period indicated in the stored IE "Periodical reporting criteria" has elapsed since the last measurement report was submitted to lower layers for a given measurement; or

– an event in stored IE "Measurement reporting criteria" was triggered. Events and triggering of reports for different measurement types are described in detail in clause 14.

For the measurement, which triggered the MEASUREMENT REPORT message, the UE shall:

1> set the IE "measurement identity" to the measurement identity, which is associated with that measurement in variable MEASUREMENT_IDENTITY;

1> set the IE "measured results" to include measurements according to the IE "reporting quantity" of that measurement stored in variable MEASUREMENT_IDENTITY; and

2> if all the reporting quantities are set to "false":

3> not set the IE "measured results".

1> set the IE "Measured results" in the IE "Additional measured results" according to the IE "reporting quantity" for all measurements associated with the measurement identities included in the "Additional measurements list" stored in variable MEASUREMENT_IDENTITY of the measurement that triggered the measurement report; and

2> if more than one additional measured result is to be included:

3> include only the available additional measured results, and sort them in ascending order according to their IE "measurement identity" in the MEASUREMENT REPORT message.

1> if the MEASUREMENT REPORT message was triggered by an event (i.e. not a periodical report):

2> set the IE "Event results" according to the event that triggered the report.

The UE shall:

1> transmit the MEASUREMENT REPORT message on the uplink DCCH using either AM or UM RLC according to the stored IE "measurement reporting mode" associated with the measurement identity that triggered the report.

When the MEASUREMENT REPORT message has been submitted to lower layers for transmission:

1> the procedure ends.

Reference

TS 25.331, clauses 8.4.1.8.1, 8.4.2, 8.4.1.3.

8.4.1.1a.3 Test Purpose

1. To confirm that the UE continues to monitor intra-frequency measurement quantity of the cells listed in System Information Block type 11 or 12 messages, after it has entered CELL_DCH state from idle mode. When the intra-frequency measurement reporting criteria specified in System Information Block type 11 or 12 messages have been met, it shall report the measurements using MEASUREMENT REPORT message(s).

2. To confirm that the UE terminates monitoring and reporting activities for the cells listed in "intra-frequency cell info list" IE in System Information Block type 11 or 12 messages, after it has received a MEASUREMENT CONTROL message that specifies the measurement type to be "intra-frequency measurement" with the same measurement identity as in System Information Block Type 11 or 12 messages.

3. To confirm that the UE reconfigures the monitoring and reporting activities based on the last MEASUREMENT CONTROL message received.

8.4.1.1a.4 Method of test

Initial Condition

System Simulator: 3 cells – Cell 1, Cell 2 and Cell 3 are active.

UE: "Registered idle mode on CS" (state 2) or "Registered idle mode on PS" (state 3) in cell 1 as specified in clause 7.4 of TS 34.108, depending on the CN domain supported by the UE If the UE supports both CS and PS domains, the initial UE state shall be "Registered idle mode on CS/PS" (state 7).

Test Procedure

Table 8.4.1.1a-1 illustrates the downlink power to be applied for the 3 cells at various time instants of the test execution.

Column marked "T0" denotes the initial conditions, while column marked as "T1" will be applied during the test.

Table 8.4.1.1a-1

Parameter

Unit

Cell 1

Cell 2

Cell 3

T0

T1

T0

T1

T0

T1

UTRA RF Channel Number

Mid Range Test Frequency

Mid Range Test Frequency

Mid Range Test Frequency

PCCPCH_RSCP

dBm

-69

-69

-74

-64

-79

-67

The UE is initially in idle mode and has selected cell 1 for camping. The System Information Block type 11 messages are modified with respect to the default settings to prevent reporting of "Cell synchronisation information" and also to include cell 2 into the monitored neighbour cell list. The key measurement parameters in the modified System Information Block message are as follow: measurement type = "intra-frequency measurement", measurement quantity = "PCCPCH RSCP", report criteria = "periodic reporting criteria", reporting interval = "64 seconds".

SS prompts the operator to make an outgoing call of a supported traffic class. SS and UE shall execute procedure P3 (for CS service) or P5 (for PS service). Next SS and UE shall execute procedure P7 (for CS service) or P9 (for PS service). Then SS and UE shall execute procedure P11 (for CS service) or P13 (for PS service).

The UE shall send a MEASUREMENT REPORT message after reaching CELL_DCH state, reporting cell 2’s PCCPCH RSCP value. After 64 seconds has passed since SS receives the first MEASUREMENT REPORT message, the UE shall transmit a second MEASUREMENT REPORT message.

SS sends a MEASUREMENT CONTROL message on the downlink DCCH. In this message, SS configures an intra-frequency measurement based on the measurement quantity PCCPCH RSCP. Parameters used in this message are: measurement identity = "1", report criteria = "event-trigger", event identity = "1g". All intra-frequency cells are removed. Cell 3 is included as new intra-frequency cell. SS checks to see that no MEASUREMENT REPORT messages are sent within the next 64 seconds (which is due to periodic reporting). SS reconfigures the downlink transmission power settings according to values in column "T1" in table 8.4.1.1a-1. The UE shall transmit a MEASUREMENT REPORT message when it detects that the PCCPCH RSCP of cell 3 is present. SS sends another MEASUREMENT CONTROL message on the downlink DCCH to include cell 2 in the monitored cells. SS configures an intra-frequency measurement based on the measurement quantity PCCPCH RSCP. Parameters used in this message are: measurement identity = "1", report criteria = "event-trigger", event identity = "1g". The UE shall transmit a MEASUREMENT REPORT message when it detects that the PCCPCH RSCP of cell 2 and indicating cell 2 as a best cell. SS calls for generic procedure C.3 to check that UE is in CELL_DCH state.

SS calls for generic procedure C.3 to check that UE is in CELL_DCH state.

Expected Sequence

Step

Direction

Message

Comment

UE

SS

1

System Information Block type 11

The UE is in idle mode and camped onto cell 1. The System Information Block type 11 messages to be transmitted are different from the default settings (see specific message contents). Cell 2 is included in CELL_INFO LIST.

2

SS executes procedure P3 (clause 7.4.2.1.2) or P5 (clause 7.4.2.2.2) specified in TS 34.108.

UE reaches PS-CELL_DCH or CS-CELL_DCH

3

SS executes procedure P7 (clause 7.4.2.3.2) or P9 (clause 7.4.2.4.2) specified in TS 34.108.

UE reaches PS-DCCH_DCH or CS-DCCH_DCH

4

SS executes procedure P11 (clause 7.4.2.5.2) or P13 (clause 7.4.2.6.2) specified in TS 34.108.

UE reaches PS-DCCH+DTCH_DCH or CS- DCCH+DTCH_DCH

5

SS

SS shall wait for a MEASUREMENT REPORT message. This MEASUREMENT REPORT shall be received on or before 64 Seconds.

6

MEASUREMENT REPORT

After receiving this message, SS shall expect to receive the next MEASUREMENT REPORT message after 64 seconds

7

MEASUREMENT REPORT

7a

7b

8

MEASUREMENT CONTROL

A measurement with "measurement identity" IE set to "1" is assigned, with the IE "CHOICE reporting criteria" set to "intra-frequency measurement reporting criteria". See specific message content for the rest of the message.

9

SS waits for 64 seconds and verifies that no further MEASUREMENT REPORT messages are detected on the uplink DCCH.

10

SS re-adjusts the downlink transmission power settings according to columns "T1" in table 8.4.1.1a-1.

11

MEASUREMENT REPORT

SS verifies that UE transmits a MEASUREMENT REPORT message triggered by cell 3 containing report the measured PCCPCH RSCP value of cell 3.

12

MEASUREMENT CONTROL

A MEASUREMENT CONTROL is sent to the UE to modify the list of the cells the UE shall monitor.

13

MEASUREMENT REPORT

SS verifies that UE transmits a MEASUREMENT REPORT message triggered by cell 2, containing report the measured PCCPCH RSCP value of cell 2. The UE shall report event 1G for change to best cell, cell2.

14



CALL C.3

If the test result of C.3 indicates that UE is in CELL_DCH state, the test passes, otherwise it fails.

Specific Message Contents

All messages indicated below shall use the same content as described in default message content, with the following exceptions:

System Information Block type 11 (Step 1)

Information Element

Value/remark

SIB12 indicator

FALSE

FACH measurement occasion info

Not Present

Measurement control system information

– Use of HCS

Not used

– Intra-frequency measurement system information

– Intra-frequency measurement identity

Not Present

Absence of this IE is equivalent to default value 1

– Intra-frequency cell info list

– CHOICE intra-frequency cell removal

Not present

(This IE shall be ignored by the UE for SIB11)

– New intra-frequency cells

– Intra-frequency cell id

1

– Cell info

– Cell individual offset

Not present

Absence of this IE is equivalent to default value 0 dB

– Reference time difference to cell

Not Present

– Read SFN Indicator

TRUE

– CHOICE Mode

TDD

– Primary CCPCH Info

Refer to clause titled "Default settings for cell No.1 (TDD)" in clause 6.1.4 of TS 34.108

– Cell selection and Re-selection

Not Present (The IE shall be absent as this is the serving cell)

– Intra-frequency cell id

2

– Cell info

– Cell individual offset

Not present

Absence of this IE is equivalent to default value 0dB

– Reference time difference to cell

1024

– Read SFN Indicator

TRUE

– CHOICE Mode

TDD

– Primary CCPCH Info

Refer to clause titled "Default settings for cell No.2 (TDD)" in clause 6.1.4 of TS 34.108

– Cell selection and Re-selection info

Not present

For neighbouring cell, if HCS is not used and all the parameters in cell selection and re-selection info are Default value, this IE is absent.

– Intra-frequency measurement quantity

– Filter Coefficient

Not Present (Default is 0)

– CHOICE Mode

TDD

– Measurement quantity list

– Measurement quantity

PCCPCH RSCP

– Intra-frequency measurement for RACH reporting

Not Present

– Maximum number of reported cells on RACH

Not Present

– Reporting information for state CELL_DCH

– Intra-frequency reporting quantity

– Reporting quantities for active set cells

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CHOICE mode

TDD

– Timeslot ISCP reporting indicator

FALSE

– Proposed TGSN Reporting required

FALSE

– PCCPCH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting quantities for monitored set cells

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CHOICE mode

TDD

– Timeslot ISCP reporting indicator

FALSE

– Proposed TGSN Reporting required

FALSE

– PCCPCH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting quantities for detected cells

Not present

– Measurement Reporting Mode

– Measurement Report Transfer Mode

Acknowledged mode RLC

– Periodical Reporting / Event Trigger Reporting Mode

Periodical reporting

– CHOICE report criteria

Periodic reporting criteria

– Amount of reporting

Infinity

– Reporting interval

64 seconds

– Inter-frequency measurement system information

Not present

– Inter-RAT measurement system information

Not Present

– Traffic volume measurement system information

Not Present

MEASUREMENT REPORT (Step 6 and 7)

Information Element

Value/remark

Measurement identity

Check to see if set to 1

Measured Results

– CHOICE measurement

Check to see if set to "Intra-frequency measured results list"

– Intra-frequency measurement results

– Cell measured results

– Cell Identity

Check to see if it is absent

– Cell synchronisation information

Check to see if this IE is absent

– CHOICE mode

TDD

– Cell parameters Id

Check to see if it’s the same for cell 2

– Proposed TGSN

Check to see if this IE is absent

– Primary CCPCH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

– Timeslot list

Check to see if this IE is absent

– Cell measured results

– Cell Identity

Check to see if this IE is absent

– Cell synchronisation information

Check to see if this IE is absent

– CHOICE mode

TDD

– Cell parameters Id

Check to see if it’s the same for cell 1

– Proposed TGSN

Check to see if this IE is absent

– Primary CCPCH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

– Timeslot list

Check to see if this IE is absent

Measured Results on RACH

Check to see if this IE is absent

Additional Measured results

Check to see if this IE is absent

Event Results

Check to see if this IE is absent

MEASUREMENT CONTROL (Step 8)

Information Element

Value/remark

Measurement Identity

1

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Event Trigger

Additional measurements list

Not Present

CHOICE measurement type

Intra-frequency measurement

– Intra-frequency cell info list

– CHOICE intra-frequency cell removal

Remove all intra-frequency cells

– New intra-frequency cells

2 new intra-frequency cells

– Intra-frequency cell id

3

– Cell info

– Cell individual offset

0 dB

– Reference time difference to cell

0 chips

– Read SFN Indicator

TRUE

– CHOICE mode

TDD

– Primary CCPCH Info

Set to same as used for cell 3

– Intra-frequency cell id

1

– Cell info

– Cell individual offset

0 dB

– Reference time difference to cell

Not Present

– Read SFN Indicator

TRUE

– CHOICE mode

TDD

– Primary CCPCH Info

Set to same code as for cell 1

– Cell for measurement

Not Present

– Intra-frequency measurement quantity

– Filter Coefficient

Not Present (Default is 0)

– CHOICE Mode

TDD

– Measurement quantity

PCCPCH RSCP

– Intra-frequency reporting quantity

– Reporting quantities for active set cells

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CHOICE mode

TDD

– Timeslot ISCP reporting indicator

FALSE

– Proposed TGSN Reporting required

FALSE

– PCCPCH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting quantities for monitored set cells

– Cell synchronisation information reporting indicator

TRUE

– Cell identity reporting indicator

FALSE

– CHOICE mode

TDD

– Timeslot ISCP reporting indicator

FALSE

– Proposed TGSN Reporting required

FALSE

– PCCPCH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting quantities for detected cells

Not present

– Reporting cell status

Not Present

– Measurement validity

Not present

– CHOICE report criteria

Intra-frequency measurement reporting criteria

– Parameters required for each events

– Intra-frequency event identity

1g

– Triggering condition 1

Not present

– Triggering condition 2

Not present

– Hysteresis

2 (1 dB)

– Time to trigger

0 ms

– Reporting cell status

Present

– CHOICE reported cell

Report cells within active and/or monitored set on used frequency or within active and/or monitored set on non-used frequency

– Maximum number of reported cells

3

MEASUREMENT REPORT (Step 11)

Information Element

Value/remark

Measurement identity

Check to see if set to 1

Measured Results

– CHOICE measurement

Check to see if set to "Intra-frequency measured results list"

– Intra-frequency measurement results

Check to see if measurement results for 2 cells are included (the order in which the different cells are reported is not important)

– Cell measured results

(for cell 1)

– Cell Identity

Check to see if it is absent

– Cell synchronisation information

Check to see if this IE is absent

– CHOICE mode

TDD

– Cell parameters Id

Check to see if it’s the same for cell 1

– Proposed TGSN

Check to see if this IE is absent

– Primary CCPCH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

– Timeslot list

Check to see if this IE is absent

– Cell measured results

(for cell 3)

– Cell Identity

Check to see if it is absent

– Cell synchronisation information

Check to see if this IE is present and that the COUNT-C-SFN frame difference is included in it.

– CHOICE mode

TDD

– Cell parameters Id

Check to see if it’s the same for cell 3

– Proposed TGSN

Check to see if this IE is absent

– Primary CCPCH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

– Timeslot list

Check to see if this IE is absent

Measured Results on RACH

Check to see if this IE is absent

Additional Measured Results

Check to see if this IE is absent

Event Results

– CHOICE event result

Check to see if this IE is set to "Intra-frequency measurement event results"

– Intra-frequency event identity

Check to see if this IE is set to "1g"

– Cell measured event results

– CHOICE mode

Check to see if this IE is set to "TDD"

– Cell parameters Id

Check to see if it’s the same for cell 3

MEASUREMENT CONTROL (Step 12)

Information Element

Value/remark

Measurement Identity

1

Measurement Command

Modify

Measurement Reporting Mode

Not Present

Additional measurements list

Not Present

CHOICE measurement type

Intra-frequency measurement

– Intra-frequency cell info list

– CHOICE intra-frequency cell removal

Remove no intra-frequency cells

– New intra-frequency info list

1 new intra-frequency cells

– Intra-frequency cell id

2

– Cell info

– Cell individual offset

0 dB

– Reference time difference to cell

Not Present

– Read SFN Indicator

FALSE

– CHOICE mode

TDD

– Primary CCPCH Info

Set to same as used for cell 2

– Cell for measurement

Not Present

– Intra-frequency measurement quantity

Not Present

– Intra-frequency reporting quantity

Not Present

– Reporting cell status

Not Present

– Measurement validity

Not Present

– CHOICE report criteria

Not Present

MEASUREMENT REPORT (Step 13)

Information Element

Value/remark

Measurement identity

Check to see if set to 1

Measured Results

– CHOICE measurement

Check to see if set to "Intra-frequency measured results list"

– Intra-frequency measurement results

Check to see if measurement results for 3 cells are included (the order in which the different cells are reported is not important)

– Cell measured results

(for cell2)

– Cell Identity

Check to see if it is absent

– Cell synchronisation information

Check to see if this IE is absent

– CHOICE mode

TDD

– Cell parameters Id

Check to see if it’s the same for cell 2

– Proposed TGSN

Check to see if this IE is absent

– Primary CCPCH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

– Timeslot list

Check to see if this IE is absent

– Cell measured results

(for cell1)

– Cell Identity

Check to see if it is absent

– Cell synchronisation information

Absent

– CHOICE mode

TDD

– Cell parameters Id

Check to see if it’s the same for cell 1

– Proposed TGSN

Check to see if this IE is absent

– Primary CCPCH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

– Timeslot list

Check to see if this IE is absent

– Cell measured results

(for cell 3)

– Cell Identity

Check to see if it is absent

– Cell synchronisation information

Check to see if this IE is present and that the COUNT-C-SFN frame difference is included in it.

– CHOICE mode

TDD

– Cell parameters Id

Check to see if it’s the same for cell 3

– Proposed TGSN

Check to see if this IE is absent

– Primary CCPCH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

– Timeslot list

Check to see if this IE is absent

Measured Results on RACH

Check to see if this IE is absent

Additional Measured Results

Check to see if this IE is absent

Event Results

– CHOICE event result

Check to see if this IE is set to "Intra-frequency measurement event results"

– Intra-frequency event identity

Check to see if this IE is set to "1g"

– Cell measured event results

– CHOICE mode

Check to see if this IE is set to "TDD"

– Primary CCPCH Info

Check to see if it’s the same code for cell 2

8.4.1.1a.5 Test Requirement

After step 5 the UE shall start to transmit 2 MEASUREMENT REPORT messages at 64 seconds interval. The measurement quantity "PCCPCH RSCP" of cell 2 shall be reported in these messages.

After step 8 the UE shall not transmit any MEASUREMENT REPORT messages within 64 seconds after SS has transmitted the MEASUREMENT CONTROL message in step 8.

After step 10 the UE shall transmit a MEASUREMENT REPORT message on the uplink DCCH, to report the PCCPCH RSCP value for cell 3. This MEASUREMENT REPORT message shall also contain IE "Event results", indicating the triggering of event ‘1g’ by cell 3. It shall also contain the measured PCCPCH RSCP value and cell synchronisation information for cell 3, and the measured PCCPCH RSCP values for cell 1.

After step 12 the UE shall transmit a MEASUREMENT REPORT message on the uplink DCCH, to report the PCCPCH RSCP value for cell 2. This MEASUREMENT REPORT message shall also contain IE "Event results", indicating the triggering of event ‘1g’ by cell 2.

8.4.1.2 Measurement Control and Report: Inter-frequency measurement for transition from idle mode to CELL_DCH state (FDD)

8.4.1.2.1 Definition

8.4.1.2.2 Conformance requirement

Upon transition from idle mode to CELL_DCH state, the UE shall:

1> stop monitoring the list of cells assigned in the IE "inter-frequency cell info list" in System Information Block type 12 (or System Information Block type 11).

Upon reception of a MEASUREMENT CONTROL message the UE shall:

1> read the IE "Measurement command";

1> if the IE "Measurement command" has the value "setup":

2> store this measurement in the variable MEASUREMENT_IDENTITY according to the IE "measurement identity", first releasing any previously stored measurement with that identity if that exists;

2> for measurement types "inter-RAT measurement" or "inter-frequency measurement" that require measurements on a frequency other than the actually used frequency:

3> if, according to its measurement capabilities, the UE requires compressed mode to perform that measurement type and after reception of this message a compressed mode pattern sequence with an appropriate measurement purpose is active according to the IE "Current TGPS Status Flag" in UE variable TGPS_IDENTITY; or

3> if, according to its measurement capabilities, the UE does not require compressed mode to perform the measurements on at least one supported band of that measurement type:

4> if the measurement is valid in the current RRC state of the UE:

5> begin measurements according to the stored control information for this measurement identity.

If the IE "Reporting Cell Status" is not received for intra-frequency, inter-frequency measurement, or inter-RAT measurement, the UE shall:

1> for intra-frequency measurement, inter-frequency measurement and inter-RAT measurement:

2> exclude the IE "Measured Results" in MEASUREMENT REPORT.

Reference

3GPP TS 25.331 clauses 8.4.1.3, 8.4.1.8.2, 8.6.6.15 and 8.6.7.9

8.4.1.2.3 Test Purpose

1. To confirm that the UE stops monitoring the list of cells assigned in the IE "inter-frequency cell info" in System Information Block type 11 messages, after it enters CELL_DCH state from idle mode.

2. To confirm that the UE, which requires compressed mode, starts to perform inter-frequency measurement and related reporting activities, when it receives a MEASUREMENT CONTROL message with the "DPCH compressed mode status info" IE indicating that a stored compressed mode pattern sequence be simultaneously activated.

3. To confirm that the UE, which does not require compressed mode, starts to perform inter-frequency measurement and related reporting activities when it receives a MEASUREMENT CONTROL message without IE "DPCH compressed mode status info".

4. To confirm that the UE excludes the IE "Measured Results" for any cells in the MEASUREMENT REPORT messages, after it receives a MEASUREMENT CONTROL message with "Reporting cell status" IE omitted.

8.4.1.2.4 Method of test

Initial Condition

System Simulator: 2 cells – Cell 1 and cell 4 are active.

UE: "Registered idle mode on CS" (state 2) or "Registered idle mode on PS" (state 3) in cell 1 as specified in clause 7.4 of TS 34.108, depending on the CN domain supported by the UE. If the UE supports both CS and PS domains, the initial UE state shall be "Registered idle mode on CS/PS" (state 7).

Related ICS/IXIT statements

– Compressed mode required yes/no

Test Procedure

Table 8.4.1.2-1 illustrates the downlink power to be applied for the 2 cells.

Table 8.4.1.2-1

Parameter

Unit

Cell 1

Cell 4

UTRA RF Channel Number

Mid Range Test Frequency

High Range Test Frequency

CPICH Ec

dBm/3.84 MHz

-60

-75

The UE is initially in idle mode and has selected cell 1 for camping.

SS prompts the operator to make an outgoing call for one of the traffic classes supported by the UE. SS and UE shall execute procedure P3 (for CS service) or P5 (for PS service). The RRC CONNECTION SETUP message used in procedure P3 or P5 should contain IE "DPCH compressed mode info", setting the "TGPS status flag" to "Deactivate" and configuring transmission pattern gap sequence with TGPSI=1 only if UE requires compressed mode. Next SS and UE shall execute procedure P7 (for CS service) or P9 (for PS service). Then SS and UE shall execute procedure P11 (for CS service) or P13 (for PS service). An optional PHYSICAL CHANNEL RECONFIGURATION message is transmitted by SS to activate the transmission pattern gap sequence with TGPSI=1, if the UE requires compressed mode to perform inter-frequency measurement. Correspondingly, the UE shall start the compressed mode operations at designated time and respond with PHYSICAL CHANNEL RECONFIGURATION COMPLETE message on the UL DCCH. The UE shall not transmit any MEASUREMENT REPORT messages, which pertain to measurement readings for cells listed in the IE "inter-frequency cell info list" in System Information Block Type 11.

If UE requires compressed mode, SS sends PHYSICAL CHANNEL RECONFIGURATION message on the downlink DCCH, specifying that compressed mode sequence pattern with TGPSI=1 be deactivated. The UE shall reply with PHYSICAL CHANNEL RECONFIGURATION COMPLETE message on the uplink DCCH if UE configures according to the PHYSICAL CHANNEL RECONFIGURATION message.

SS sends MEASUREMENT CONTROL message on the downlink DCCH. In this message, SS requests UE to perform inter-frequency measurement with periodic reporting of CPICH RSCP values for cell 4. If UE requires compressed mode, IE "DPCH compressed status info" IE to activate the transmission gap pattern sequence with TGPSI = 1 is included in this message.

The UE shall start inter-frequency measurement and reporting for cell 4’s CPICH RSCP values. It shall report this measurement result by transmitting MEASUREMENT REPORT messages on uplink DCCH periodically at 16 seconds interval.

SS sends MEASUREMENT CONTROL message on the downlink DCCH omitting the IE "Reporting cell status". The UE shall send MEASUREMENT REPORT messages on the uplink DCCH, with the IE "Cell measured results" excluded in these messages. SS calls for generic procedure C.3 to check that UE is in CELL_DCH state.

Expected Sequence

Step

Direction

Message

Comment

UE

SS

1

System Information Block type 11

The UE is idle mode and camped onto cell 1.System Information Block Type 11 to be transmitted is different from the default settings (see specific message contents)

2

SS executes procedure P3 (clause 7.4.2.1.2) or P5 (clause 7.4.2.2.2) specified in TS 34.108.

SS prompts the operator to make an outgoing call.

3

SS executes procedure P7 (clause 7.4.2.3.2) or P9 (clause 7.4.2.4.2) specified in TS 34.108.

4

SS executes procedure P11 (clause 7.4.2.5.2) or P13 (clause 7.4.2.6.2) specified in TS 34.108.

5

Void (if compressed mode is not required by the UE), or PHYSICAL CHANNEL

RECONFIGURATION (if compressed mode is required by the UE)

If compressed mode is not required (refer ICS/IXIT), then goto step 6. Else, activate the compressed mode operation.

5a

Void (if compressed mode is not required by the UE), or PHYSICAL CHANNEL RECONFIGURATION COMPLETE (if compressed mode is required by the UE)

UE shall remain in CELL_DCH state.

6

SS checks to see that no MEASUREMENT REPORT messages are received for 10 s.

If compressed mode is not required (refer ICS/IXIT), then goto step 9.

7

Void (if compressed mode is not required by the UE), or PHYSICAL CHANNEL RECONFIGURATION (if compressed mode is required by the UE)

Existing compressed mode sequence pattern is de-activated in this message.

8

Void (if compressed mode is not required by the UE), or PHYSICAL CHANNEL RECONFIGURATION COMPLETE (if compressed mode is required by the UE)

UE shall remain in CELL_DCH state.

9

MEASUREMENT CONTROL

SS requests UE to start inter-frequency measurement for cell 4, and performing periodic reporting for cell 4’s CPICH RSCP. See specific message content below.

10

MEASUREMENT REPORT

UE shall report cell 4’s CPICH RSCP reading periodically.

11

MEASUREMENT CONTROL

SS changes the reporting criteria of cell 4 to ‘event 2c’. "Reporting cell status" IE in this message is omitted.

12

MEASUREMENT REPORT

SS monitors the uplink DCCH to make sure that only 1 such message is received almost immediately after step 11. This message shall not contain IE "Inter-frequency cell measured results"

13



CALL C.3

If the test result of C.3 indicates that UE is in CELL_DCH state, the test passes, otherwise it fails.

Specific Message Content

All messages indicated below shall use the same content as described in default message content, with the following exceptions:

System Information Block type 11 (Step 1)

Information Element

Value/remark

SIB12 indicator

FALSE

FACH measurement occasion info

Not Present

Measurement control system information

-Use of HCS

Not used

-Cell selection and reselection quality measure

CPICH Ec/No

– Intra-frequency measurement system information

– Intra-frequency measurement identity

Not present

– Intra-frequency cell info list

– CHOICE intra-frequency cell removal

Not Present

– New intra-frequency cells

– Intra-frequency cell id

1

– Cell info

– Cell individual offset

Not Present

– Reference time difference to cell

Not present

– Read SFN indicator

TRUE

– CHOICE mode

FDD

– Primary CPICH info

– Primary scrambling code

Refer to clause titled "Default settings for cell No.1 (FDD)" in clause 6.1.4 of TS 34.108

– Primary CPICH Tx power

Not present

– TX Diversity indicator

FALSE

– Cell Selection and Re-selection info

Not present

– Cells for measurement

Not present

– Intra-frequency measurement quantity

Not present

– Intra-frequency reporting quantity for RACH reporting

Not present

– Maximum number of reported cells on RACH

Not present

– Reporting information for state CELL_DCH

Not present

– Inter-frequency measurement system information

– Inter-frequency cell info list

– CHOICE inter-frequency cell removal

Not present

– New inter-frequency cells

– Inter-frequency cell id

4

– Frequency info

– CHOICE mode

FDD

– UARFCN uplink (Nu)

Not present

Absence of this IE is equivalent to applying the default duplex distance defined for the operating frequency according to 3GPP TS 25.101 [21]

– UARFCN downlink (Nd)

Reference to table 6.1.2 of TS34.108 for Cell 4

– Cell info

– Cell individual offset

Not Present

– Reference time difference to cell

Not Present

– Read SFN Indicator

FALSE

– CHOICE mode

FDD

– Primary CPICH Info

– Primary Scrambling Code

Refer to clause titled "Default settings for cell No.4 (FDD)" in clause 6.1.4 of TS 34.108

– Primary CPICH TX power

Not Present

– TX Diversity Indicator

FALSE

– Cell selection and re-selection info

Not present

For neighbouring cell, if HCS is not used and all the parameters in cell selection and re-selection info are Default value, this IE is absent.

-Cells for measurement

Not Present

– Inter-RAT measurement system information

Not Present

– Traffic volume measurement system information

Not Present

RRC CONNECTION SETUP (Step 2)

If UE do not require compressed mode, use the message found in TS 34.108 clause 9.

If UE requires compressed mode, use the message found in TS 34.108 clause 9, with the following exceptions:

Information Element

Value/remark

Version

Downlink information common for all radio links

– Downlink DPCH info common for all RL

– Timing Indication

Initialise

– CFN-targetSFN frame offset

Not Present

– Downlink DPCH power control information

– DPC mode

Single TPC

– CHOICE Mode

FDD

– Power offset PPilot-DPDCH

0

– DL rate matching restriction information

Not Present

– Spreading factor

Refer to the parameter set in TS 34.108

– Fixed or flexible position

Fixed

– TFCI existence

FALSE

– Number of bits for Pilot bits (SF=128, 256)

Refer to the parameter set in TS 34.108

– DPCH compressed mode info

– TGPSI

1

– TGPS Status Flag

Deactivate

– TGCFN

Not Present

– Transmission gap pattern sequence configuration parameters

– TGMP

FDD Measurement

– TGPRC

Infinity

– TGSN

4

– TGL1

7

– TGL2

Not Present

– TGD

Undefined

– TGPL1

3

– TGPL2

Not Present

R99 and REL-4 only

– RPP

Mode 0

– ITP

Mode 0

– CHOICE UL/DL Mode

UL and DL, UL only or DL only depending the on UE capability

– Downlink compressed mode method

SF/2 (or Not present depending on the UE capability)

– Uplink compressed mode method

SF/2 or Not present depending on the UE capability

– Downlink frame type

B

– DeltaSIR1

20 (2.0)

– DeltaSIRAfter1

10 (1.0)

– DeltaSIR2

Not Present

– DeltaSIR2After2

Not Present

– N identify abort

Not Present

– T Reconfirm abort

Not Present

– TX Diversity Mode

None

– SSDT information

Not Present

R99 and Rel-4 only

– Default DPCH Offset Value

0

Downlink information for each radio link list

– Downlink information for each radio link

– CHOICE mode

FDD

– Primary CPICH info

– Primary scrambling code

Reference to 34.108

– PDSCH with SHO DCH info

Not Present

– PDSCH code mapping

Not Present

– Downlink DPCH info for each RL

– Primary CPICH usage for channel estimation

Primary CPICH can be used

– DPCH frame offset

Set to value: Default DPCH Offset value mod 38400

– Secondary CPICH info

Not Present

– DL Channelisation code

– Secondary scrambling code

1

– Spreading factor

Reference to 34.108

– Code number

0

– Scrambling code change

No code change

– TPC combination index

0

– SSDT Cell identity

Not present

R99 and Rel-4 only

– Closed loop timing adjustment mode

Not present

SCCPCH information for FACH

Not present

R99 and Rel-4 only

PHYSICAL CHANNEL RECONFIGURATION (Step 5)

Use the same message sub-type in clause 9 of TS 34.108 titled "Non speech in CS" or "Speech in CS" or "Packet to CELL_DCH from CELL_DCH in PS", with Scrambling code change set to Default1 and with the following exceptions:

Information Element

Value/remark

Version

Downlink information common for all radio links

– Downlink DPCH info common for all RL

– Timing Indication

Maintain

– Downlink DPCH power control information

– DPC mode

0 (single)

– CHOICE mode

FDD

– Power offset PPilot-DPDCH

0

– DL rate matching restriction information

Not Present

– Spreading factor

Reference to TS34.108 clause 6.10 Parameter Set

– Fixed or Flexible Position

Reference to TS34.108 clause 6.10 Parameter Set

– TFCI existence

Reference to TS34.108 clause 6.10 Parameter Set

– CHOICE SF

Reference to TS34.108 clause 6.10 Parameter Set

– DPCH compressed mode info

– TGPSI

1

– TGPS Status Flag

Activate

– TGCFN

(Current CFN + (256 – TTI/10msec))mod 256

– Transmission gap pattern sequence configuration parameters

Not Present

Downlink information per radio link list

– Downlink information for each radio link

– Choice mode

FDD

– Primary CPICH info

– Primary scrambling code

Ref. to the Default setting in clause 6.1 (FDD)

– PDSCH with SHO DCH info

Not Present

R99 and Rel-4 only

-PDSCH code mapping

Not Present

R99 and Rel-4 only

– Downlink DPCH info for each RL

– CHOICE mode

FDD

– Primary CPICH usage for channel estimation

Primary CPICH may be used

– DPCH frame offset

Set to value : Default DPCH Offset Value (as currently stored in SS) mod 38 400

– Secondary CPICH info

Not Present

– DL channelisation code

– Secondary scrambling code

1

– Spreading factor

Reference to clause 6.10 Parameter Set

– Code number

0

– Scrambling code change

Set to value Default1: No code change (if the UE has a compressed mode pattern sequence configured in variable TGPS_IDENTITY or included in the message including IE "Downlink DPCH info for each RL", which is using compressed mode method "SF/2")

– TPC combination index

0

– SSDT Cell Identity

Not Present

R99 and Rel-4 only

– Closed loop timing adjustment mode

Not Present

– SCCPCH information for FACH

Not Present

R99 and Rel-4 only

PHYSICAL CHANNEL RECONFIGURATION (Step 7)

Use the same message sub-type in clause 9 of TS 34.108 titled "Non speech in CS" or "Speech in CS" or "Packet to CELL_DCH from CELL_DCH in PS", with Scrambling code change set to Default1 and with the following exceptions:

Information Element

Value/remark

Version

Downlink information common for all radio links

– Downlink DPCH info common for all RL

– Timing Indication

Maintain

– Downlink DPCH power control information

– DPC mode

0 (single)

– CHOICE mode

FDD

– Power offset PPilot-DPDCH

0

– DL rate matching restriction information

Not Present

– Spreading factor

Reference to TS34.108 clause 6.10 Parameter Set

– Fixed or Flexible Position

Reference to TS34.108 clause 6.10 Parameter Set

– TFCI existence

Reference to TS34.108 clause 6.10 Parameter Set

– Number of bits for Pilot bits (SF=128,256)

Reference to TS34.108 clause 6.10 Parameter Set

– DPCH compressed mode info

– Transmission gap pattern sequence

– TGPSI

1

– TPGS status Flag

Deactivate

– TGCFN

– Transmission gap pattern sequence configuration parameters

Not Present

Not Present

– TX Diversity mode

None

– SSDT information

Not Present

R99 and Rel-4 only

– Default DPCH Offset Value

Not Present

Downlink information per radio link list

– Choice mode

FDD

– Primary CPICH info

– Primary scrambling code

Ref. to the Default setting in clause 6.1 (FDD)

– PDSCH with SHO DCH info

Not Present

R99 and Rel-4 only

– PDSCH code mapping

Not Present

R99 and Rel-4 only

– Serving HS-DSCH radio link indicator

FALSE

Rel-5

– Serving E-DCH radio link indicator

FALSE

Rel-6

– Downlink DPCH info for each RL

– CHOICE mode

FDD

– Primary CPICH usage for channel estimation

Primary CPICH may be used

– DPCH frame offset

Set to value : Default DPCH Offset Value (as currently stored in SS) mod 38 400

– Secondary CPICH info

Not Present

– DL channelisation code

– Secondary scrambling code

5

– Spreading factor

Reference to clause 6.10 Parameter Set

– Code number

0

– Scrambling code change

Set to value Default1: No code change (if the UE has a compressed mode pattern sequence configured in variable TGPS_IDENTITY or included in the message including IE "Downlink DPCH info for each RL", which is using compressed mode method "SF/2")

– TPC combination index

0

– SSDT Cell Identity

Not Present

R99 and Rel-4 only

– Closed loop timing adjustment mode

Not Present

– E-AGCH Info

Not Present

Rel-6

– E-HICH Information

Not Present

Rel-6

– E-RGCH Information

Not Present

Rel-6

– SCCPCH information for FACH

Not Present

R99 and Rel-4 only

MEASUREMENT CONTROL (Step 9)

If UE requires compressed mode.

Information Element

Value/remark

Measurement Identity

1

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodical Reporting / Event Trigger Reporting Mode

Periodical reporting

Additional measurements list

Not Present

CHOICE measurement type

Inter-frequency measurement

– Inter-frequency cell info list

– CHOICE inter-frequency cell removal

No inter-frequency cells removed

– New inter-frequency info list

– Inter-frequency cell id

4

– Frequency info

– UARFCN uplink (Nu)

Not present

Absence of this IE is equivalent to applying the default duplex distance defined for the operating frequency according to 3GPP TS 25.101 [21]

– UARFCN downlink (Nd)

UARFCN of the downlink frequency for cell 4

– Cell info

– Cell individual offset

0 dB

– Reference time difference to cell

Not Present

– Read SFN Indicator

FALSE

– CHOICE mode

FDD

– Primary CPICH Info

– Primary Scrambling Code

Set to same code as used for cell 4

– Primary CPICH TX power

Not Present

– TX Diversity Indicator

FALSE

– Cells for measurement

Not Present

– Inter-frequency measurement quantity

– CHOICE reporting criteria

Inter-frequency reporting criteria

– Filter Coefficient

Not Present

– Measurement quantity for frequency quality estimate

CPICH RSCP

– Inter-frequency reporting quantity

– UTRA Carrier RSSI

FALSE

– Frequency quality estimate

FALSE

– Non frequency related cell reporting quantities

– Cell synchronisation information reporting indicator

FALSE

– Cell Identity reporting indicator

FALSE

– CPICH Ec/No reporting indicator

FALSE

– CPICH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting cell status

– CHOICE reported cell

Report cell within active and/or monitored set on used frequency or within active and/or monitored set on non-used frequency

– Maximum number of reported cells

2

– Measurement validity

Not present

– Inter-frequency set update

Not present

– CHOICE report criteria

Periodic reporting criteria

– Amount of reporting

Infinity

– Reporting interval

16 seconds

DPCH compressed mode status info

– TGPS reconfiguration CFN

(Current CFN + (256 – TTI/10msec))mod 256

– Transmission gap pattern sequence

– TGPSI

1

– TGPS Status Flag

Activate

– TGCFN

(Current CFN + (256 – TTI/10msec))mod 256

If UE do not require compressed mode.

Information Element

Value/Remark

Measurement Identity

1

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Periodical reporting

Additional measurements list

Not Present

CHOICE measurement type

Inter-frequency measurement

– Inter-frequency cell info list

– CHOICE inter-frequency cell removal

No inter-frequency cells removed

– New inter-frequency info list

– Inter-frequency cell id

4

– Frequency info

– UARFCN uplink (Nu)

Not present

Absence of this IE is equivalent to applying the default duplex distance defined for the operating frequency according to 3GPP TS 25.101 [21]

– UARFCN downlink (Nd)

UARFCN of the downlink frequency for cell 4

– Cell info

– Cell individual offset

0 dB

– Reference time difference to cell

Not Present

– Read SFN Indicator

FALSE

– CHOICE mode

FDD

– Primary CPICH Info

– Primary Scrambling Code

Set to same code as used for cell 4

– Primary CPICH TX power

Not Present

– TX Diversity Indicator

FALSE

– Cells for measurement

– Inter-frequency cell id

4

– Inter-frequency measurement quantity

– CHOICE reporting criteria

Inter-frequency reporting criteria

– Filter Coefficient

Not Present

– Measurement quantity for frequency quality estimate

CPICH RSCP

– Inter-frequency reporting quantity

– UTRA Carrier RSSI

FALSE

– Frequency quality estimate

FALSE

– Non frequency related cell reporting quantities

– Cell synchronisation information reporting indicator

FALSE

– Cell Identity reporting indicator

FALSE

– CPICH Ec/No reporting indicator

FALSE

– CPICH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting cell status

– CHOICE reported cell

Report cell within active and/or monitored set on used frequency or within active and/or monitored set on non-used frequency

– Maximum number of reported cells

2

– Measurement validity

Not present

– Inter-frequency set update

Not present

– CHOICE report criteria

Periodic reporting criteria

– Amount of reporting

Infinity

– Reporting interval

16 seconds

DPCH compressed mode status info

Not Present

MEASUREMENT REPORT (Step 10)

Information Element

Value/remark

Measurement identity

Check to see if set to 1

Measured Results

– CHOICE measurement

Check to see if set to "Inter-frequency measured results list"

– Inter-frequency measurement results

– Frequency info

– UARFCN uplink

The presence of this IE is not checked

– UARFCN downlink

Check that the value of this IE is set to UARFCN for the downlink corresponding to f4

– UTRA carrier RSSI

Check to see if it is absent

– Inter-frequency cell measurement results

– Cell measured results

– Cell Identity

Check to see if it is absent

– Cell synchronisation information

Check to see if it is absent

– Primary CPICH Info

– Primary Scrambling Code

Check to see if set to the same code for cell 4

– CPICH Ec/No

Check to see if it is absent

– CPICH RSCP

Check to see if it is present

– Pathloss

Check to see if it is absent

Measured Results on RACH

Check to see if it is absent

Additional Measured results

Check to see if it is absent

Event Results

Check to see if it is absent

MEASUREMENT CONTROL (Step 11)

Information Element

Value/remark

Measurement Identity

1

Measurement Command

Set up

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Event Trigger

Additional measurements list

Not Present

CHOICE measurement type

Inter-frequency measurement

– Inter-frequency cell info list

– CHOICE inter-frequency cell removal

No inter-frequency cells removed

– New inter-frequency info list

– Inter-frequency cell id

4

– Frequency info

– UARFCN uplink (Nu)

UARFCN of the uplink frequency for cell 4

– UARFCN downlink (Nd)

Not present

Absence of this IE is equivalent to applying the default duplex distance defined for the operating frequency according to 3GPP TS 25.101 [21]

– Cell info

– Cell individual offset

0 dB

– Reference time difference to cell

Not Present

– Read SFN Indicator

FALSE

– CHOICE mode

FDD

– Primary CPICH Info

– Primary Scrambling Code

Set to same code as used for cell 4

– Primary CPICH TX power

Not Present

– TX Diversity Indicator

FALSE

– Cells for measurement

Not Present

– Inter-frequency measurement quantity

– CHOICE reporting criteria

Inter-frequency reporting criteria

– Filter Coefficient

Not Present

– Measurement quantity for frequency quality estimate

CPICH RSCP

– Inter-frequency reporting quantity

– UTRA Carrier RSSI

FALSE

– Frequency quality estimate

FALSE

– Non frequency related cell reporting quantities

– Cell synchronisation information reporting indicator

FALSE

– Cell Identity reporting indicator

FALSE

– CPICH Ec/No reporting indicator

FALSE

– CPICH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting cell status

Not Present

– Measurement validity

Not present

– Inter-frequency set update

-UE Autonomous update mode

On with no reporting

-Non autonomous update mode

Not Present

– CHOICE report criteria

Inter-frequency measurement reporting criteria

– Parameters required for each event

– Inter-frequency event identity

2c

– Threshold used frequency

Not Present

– W used frequency

Not Present

– Hysteresis

1 (0.5 dB)

– Time to trigger

0 milliseconds

– Reporting cell status

Not Present

– Parameters required for each non-used frequency

– Threshold non used frequency

-85 dBm

– W non used frequency

0

DPCH compressed mode status info

Not Present

MEASUREMENT REPORT (Step 12)

Information Element

Value/remark

Measurement identity

Check to see if set to 1

Measured Results

Check to see if it is absent

Measured Results on RACH

Check to see if it is absent

Additional Measured Results

Check to see if it is absent

Event Results

– CHOICE event result

Check to see if this IE is set to "Inter-frequency measurement event results"

– Inter-frequency event identity

Check to see if this IE is set to "2c"

– Inter-frequency cells

– Frequency info

– UARFCN uplink

The presence of this IE is not checked

– UARFCN downlink

Check that the value of this IE is set to UARFCN for the downlink corresponding to f4

– Non frequency related measurement event results

– CHOICE Mode

Check to see if set to "FDD"

– Primary CPICH info

– Primary Scrambling Code

Check to see if set to the same code as cell 4

8.4.1.2.5 Test Requirement

After step 5 the UE shall not transmit any MEASUREMENT REPORT messages pertaining to the measurement of CPICH RSCP of cell 4.

If UE requires compressed mode operation, after step 5, UE shall activate compressed mode operations at the time indicated by IE "TGCFN" and then transmit PHYSICAL CHANNEL RECONFIGURATION COMPLETE message on uplink DCCH using AM RLC.

If UE requires compressed mode, after step 7, UE shall transmit PHYSICAL CHANNEL RECONFIGURATION COMPLETE message on uplink DCCH using AM RLC.

After step 9 the UE shall transmit MEASUREMENT REPORT messages on uplink DCCH, reporting cell 4’s CPICH RSCP value at periodic time interval of 16 seconds in "inter-frequency cell measurement results" IE.

After step 11 the UE shall transmit only 1 MEASUREMENT REPORT message on the uplink DCCH. In this message, IE "Measured Results" shall be absent.

8.4.1.2a Measurement Control and Report: Inter-frequency measurement for transition from idle mode to CELL_DCH state (TDD)

8.4.1.2a.1 Definition

8.4.1.2a.2 Conformance requirement

Upon transition from idle mode to CELL_DCH state, the UE shall:

1> stop monitoring the list of cells assigned in the IE "inter-frequency cell info list" in System Information Block type 12 (or System Information Block type 11).

Upon reception of a MEASUREMENT CONTROL message the UE shall:

1> read the IE "Measurement command";

1> if the IE "Measurement command" has the value "setup":

2> store this measurement in the variable MEASUREMENT_IDENTITY according to the IE "measurement identity", first releasing any previously stored measurement with that identity if that exists;

2> for measurement types "inter-frequency measurement":

3> if the IE "Inter-frequency cell info list" for that measurement identity is empty; or

3> if, according to its measurement capabilities, the UE does not require compressed mode to perform the measurements:

4> if the measurement is valid in the current RRC state of the UE:

5> begin measurements according to the stored control information for this measurement identity.

If the IE "Reporting Cell Status" is not received for inter-frequency measurement, the UE shall:

1> exclude the IE "Cell Measured Results" for any cell in MEASUREMENT REPORT.

Reference

3GPP TS 25.331 clauses 8.4.1.3, 8.4.1.8.2 and 8.6.7.9

8.4.1.2a.3 Test Purpose

1. To confirm that the UE stops monitoring the list of cells assigned in the IE "inter-frequency cell info" in System Information Block type 11 messages, after it enters CELL_DCH state from idle mode.

2. To confirm that the UE excludes the IE "cell measured results" for any cells in the MEASUREMENT REPORT messages, after it receives a MEASUREMENT CONTROL message with "Reporting cell status" IE omitted.

8.4.1.2a.4 Method of test

Initial Condition

System Simulator: 2 cells – Cell 1 and cell 4 are active.

UE: "Registered idle mode on CS" (state 2) or "Registered idle mode on PS" (state 3) in cell 1 as specified in clause 7.4 of TS 34.108, depending on the CN domain supported by the UE. If the UE supports both CS and PS domains, the initial UE state shall be "Registered idle mode on CS/PS" (state 7).

Test Procedure

Table 8.4.1.2a-1 illustrates the downlink power to be applied for the 2 cells.

Table 8.4.1.2a-1

Parameter

Unit

Cell 1

Cell 4

UTRA RF Channel Number

Mid Range Test Frequency

High Range Test Frequency

PCCPCH RSCP

dBm

-60

-75

The UE is initially in idle mode and has selected cell 1 for camping.

SS prompts the operator to make an outgoing call for one of the traffic classes supported by the UE. SS and UE shall execute procedure P3 (for CS service) or P5 (for PS service). Next SS and UE shall execute procedure P7 (for CS service) or P9 (for PS service). Then SS and UE shall execute procedure P11 (for CS service) or P13 (for PS service).The UE shall not transmit any MEASUREMENT REPORT messages, which pertain to measurement readings for cells listed in the IE "inter-frequency cell info list" in System Information Block Type 11.

SS sends MEASUREMENT CONTROL message on the downlink DCCH. In this message, SS requests UE to perform inter-frequency measurement with periodic reporting of PCCPCH RSCP values for cell 4.

The UE shall start inter-frequency measurement and reporting for cell 4’s PCCPCH RSCP values. It shall report this measurement result by transmitting MEASUREMENT REPORT messages on uplink DCCH periodically at 16 seconds interval.

SS sends MEASUREMENT CONTROL message on the downlink DCCH omitting the IE "Reporting cell status". The UE shall send MEASUREMENT REPORT messages on the uplink DCCH, with the IE "Cell measured results" excluded in these messages. SS calls for generic procedure C.3 to check that UE is in CELL_DCH state.

Expected Sequence

Step

Direction

Message

Comment

UE

SS

1

System Information Block type 11

The UE is idle mode and camped onto cell 1.System Information Block Type 11 to be transmitted is different from the default settings (see specific message contents)

2

SS executes procedure P3 (clause 7.4.2.1.2) or P5 (clause 7.4.2.2.2) specified in TS 34.108.

SS prompts the operator to make an outgoing call.

3

SS executes procedure P7 (clause 7.4.2.3.2) or P9 (clause 7.4.2.4.2) specified in TS 34.108.

4

SS executes procedure P11 (clause 7.4.2.5.2) or P13 (clause 7.4.2.6.2) specified in TS 34.108. UE keeps the connection on the secondary carrier of Cell 2.

5

Void

6

SS checks to see that no MEASUREMENT REPORT messages are received.

7

MEASUREMENT CONTROL

SS requests UE to start inter-frequency measurement for cell 4, and performing periodic reporting for cell 4’s PCCPCH RSCP. See specific message content below.

8

MEASUREMENT REPORT

UE shall report cell 4’s PCCPCH RSCP reading periodically.

9

MEASUREMENT CONTROL

SS changes the reporting criteria of cell 4 to ‘event 2c’. "Reporting cell status" IE in this message is omitted.

10

MEASUREMENT REPORT

SS monitors the uplink DCCH to make sure that only 1 such message is received almost immediately after step 9. This message shall not contain IE "Inter-frequency cell measured results"

11



CALL C.3

If the test result of C.3 indicates that UE is in CELL_DCH state, the test passes, otherwise it fails.

Specific Message Content

All messages indicated below shall use the same content as described in default message content, with the following exceptions:

System Information Block type 11 (Step 1)

Information Element

Value/remark

SIB12 indicator

FALSE

FACH measurement occasion info

Not Present

Measurement control system information

-Use of HCS

Not used

– Intra-frequency measurement system information

– Intra-frequency measurement identity

Not present

– Intra-frequency cell info list

– CHOICE intra-frequency cell removal

Not Present

– New intra-frequency cells

– Intra-frequency cell id

1

– Cell info

– Cell individual offset

Not Present

– Reference time difference to cell

Not present

– Read SFN indicator

TRUE

– CHOICE mode

TDD

– Primary CCPCH Info

Refer to clause titled "Default settings for cell No.1 (TDD)" in clause 6.1.4 of TS 34.108

– Cell Selection and Re-selection info

Not present

– Intra-frequency measurement quantity

Not present

– Intra-frequency reporting quantity for RACH reporting

Not present

– Maximum number of reported cells on RACH

Not present

– Reporting information for state CELL_DCH

Not present

– Inter-frequency measurement system information

– Inter-frequency cell info list

– CHOICE inter-frequency cell removal

Not present

– New inter-frequency cells

– Inter-frequency cell id

4

– Frequency info

– CHOICE mode

TDD

– UARFCN (Nt)

Reference to table 6.1.4 of TS34.108 for Cell 4

– Cell info

– Cell individual offset

Not Present

– Reference time difference to cell

Not Present

– Read SFN Indicator

FALSE

– CHOICE mode

TDD

– Primary CCPCH Info

Refer to clause titled "Default settings for cell No.4 (TDD)" in clause 6.1.4 of TS 34.108

– Primary CCPCH TX power

Not Present

– Timeslot list

Not Present

– Cell selection and re-selection info

Not present

For neigbouring cell, if HCS is not used and all the parameters in cell selection and re-selection info are Default value, this IE is absent.

– Inter-RAT measurement system information

Not Present

– Traffic volume measurement system information

Not Present

RRC CONNECTION SETUP (Step 2)

UE will use the message found in TS 34.108 clause 9.

MEASUREMENT CONTROL (Step 7)

Information Element

Value/Remark

Measurement Identity

1

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Periodical reporting

Additional measurements list

Not Present

CHOICE measurement type

Inter-frequency measurement

– Inter-frequency cell info list

– CHOICE inter-frequency cell removal

No inter-frequency cells removed

– New inter-frequency info list

– Inter-frequency cell id

4

– Frequency info

– CHOICE mode

TDD

– UARFCN (Nt)

UARFCN of the frequency for cell 4

– Cell info

– Cell individual offset

0 dB

– Reference time difference to cell

Not Present

– Read SFN Indicator

FALSE

– CHOICE mode

TDD

– Primary CCPCH Info

Set to same as used for cell 4

– Primary CCPCH TX power

Not Present

– Timeslot list

Not Present

– Cells for measurement

Not Present

– Inter-frequency measurement quantity

– CHOICE reporting criteria

Inter-frequency reporting criteria

– Filter Coefficient

0

– CHOICE mode

TDD

– Measurement quantity for frequency quality estimate

PCCPCH RSCP

– Inter-frequency reporting quantity

– UTRA Carrier RSSI

FALSE

– Frequency quality estimate

FALSE

– Non frequency related cell reporting quantities

– Cell synchronisation information reporting indicator

FALSE

– Cell Identity reporting indicator

FALSE

– CHOICE mode

TDD

– Timeslot ISCP reporting indicator

FALSE

– Proposed TGSN Reporting required

FALSE

– Primary CCPCH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting cell status

– CHOICE reported cell

Report cell within active and/or monitored set on used frequency or within virtual active and/or monitored set on non-used frequency

– Maximum number of reported cells

2

– Measurement validity

Not present

– Inter-frequency set update

Not present

– CHOICE report criteria

Periodic reporting criteria

– Amount of reporting

Infinity

– Reporting interval

16 seconds

DPCH compressed mode status info

Not Present

MEASUREMENT REPORT (Step 8)

Information Element

Value/remark

Measurement identity

Check to see if set to 1

Measured Results

– CHOICE measurement

Check to see if set to "Inter-frequency measured results list"

– Inter-frequency measurement results

– Frequency info

– CHOICE mode

TDD

– UARFCN (Nt)

Check to see if set to the UARFCN of the frequency for cell 4

– UTRA carrier RSSI

Check to see if it is absent

– Inter-frequency cell measurement results

– Cell measured results

– Cell Identity

Check to see if it is absent

– Cell synchronisation information

Check to see if it is absent

– CHOICE mode

TDD

– cell parameters identity

Check to see if set to the same for cell 4

– proposed TGSN

Check to see if it is absent

– PCCPCH RSCP

Check to see if it is present

– Pathloss

Check to see if it is absent

– timeslot list

Check to see if it is absent

Measured Results on RACH

Check to see if it is absent

Additional Measured results

Check to see if it is absent

Event Results

Check to see if it is absent

MEASUREMENT CONTROL (Step 9)

Information Element

Value/remark

Measurement Identity

1

Measurement Command

Set up

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Event Trigger

Additional measurements list

Not Present

CHOICE measurement type

Inter-frequency measurement

– Inter-frequency cell info list

– CHOICE inter-frequency cell removal

No inter-frequency cells removed

– New inter-frequency info list

– Inter-frequency cell id

4

– Frequency info

– UARFCN uplink (Nt)

UARFCN of the frequency for cell 4

– Cell info

– Cell individual offset

0 dB

– Reference time difference to cell

Not Present

– Read SFN Indicator

FALSE

– CHOICE mode

TDD

– Primary CCPCH Info

Set to same as used for cell 4

– Primary CCPCH TX power

Not Present

– Timeslot list

Not Present

– Cells for measurement

Not Present

– Inter-frequency measurement quantity

– CHOICE reporting criteria

Inter-frequency reporting criteria

– Filter Coefficient

0

– CHOICE mode

TDD

– Measurement quantity for frequency quality estimate

PCCPCH RSCP

– Inter-frequency reporting quantity

– UTRA Carrier RSSI

FALSE

– Frequency quality estimate

FALSE

– Non frequency related cell reporting quantities

– Cell synchronisation information reporting indicator

FALSE

– Cell Identity reporting indicator

FALSE

– CHOICE mode

TDD

– Timeslot ISCP reporting indicator

FALSE

– Proposed TGSN Reporting required

FALSE

– Primary CCPCH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Measurement validity

Not present

– Inter-frequency set update

Not present

– CHOICE report criteria

Inter-frequency measurement reporting criteria

– Parameters required for each event

– Inter-frequency event identity

2c

– Threshold used frequency

Not Present

– W used frequency

Not Present

– Hysteresis

1 (0.5 dB)

– Time to trigger

0 milliseconds

– Reporting cell status

Not Present

– Parameters required for each non-used frequency

– Threshold non used frequency

-85 dBm

– W non used frequency

0

DPCH compressed mode status info

Not Present

MEASUREMENT REPORT (Step 10) (3.84 Mcps TDD)

Information Element

Value/remark

Measurement identity

Check to see if set to 1

Measured Results

Check to see if it is absent

Measured Results on RACH

Check to see if it is absent

Additional Measured Results

Check to see if it is absent

Event Results

– CHOICE event result

Check to see if this IE is set to "Inter-frequency measurement event results"

– Inter-frequency event identity

Check to see if this IE is set to "2c"

– Inter-frequency cells

– Frequency info

– CHOICE mode

TDD

– UARFCN(Nt)

Check to see if set to the UARFCN of the frequency for cell 4

– Non frequency related measurement event results

– CHOICE Mode

Check to see if set to "TDD"

– Primary CCPCH info

– CHOICE Mode

Check to see if set to "TDD"

– CHOICE TDD option

Check to see if set to "3.84 Mcps TDD”

– CHOICE Sync Case

Check to see if set to " Sync Case 1”

– Timeslot

Check to see if it’s the same for cell 4 (S/B 0)

– Cell parameters Id

Check to see if it’s the same for cell 4

– SCTD indicator

Check to see if set to "FALSE”

MEASUREMENT REPORT (Step 10) (1.28 Mcps TDD)

Information Element

Value/remark

Measurement identity

Check to see if set to 1

Measured Results

Check to see if it is absent

Measured Results on RACH

Check to see if it is absent

Additional Measured Results

Check to see if it is absent

Event Results

– CHOICE event result

Check to see if this IE is set to "Inter-frequency measurement event results"

– Inter-frequency event identity

Check to see if this IE is set to "2c"

– Inter-frequency cells

– Frequency info

– CHOICE mode

TDD

– UARFCN(Nt)

Check to see if set to the UARFCN of the frequency for cell 4

– Non frequency related measurement event results

– CHOICE Mode

Check to see if set to "TDD"

– Primary CCPCH info

– CHOICE Mode

Check to see if set to "TDD"

– CHOICE TDD option

Check to see if set to "1.28 Mcps TDD”

– TSTD indicator

Check to see if set to "FALSE”

– Cell parameters Id

Check to see if it’s the same for cell 4

– SCTD indicator

Check to see if set to "FALSE”

– Primary CCPCH info

Check to see if set to the same as cell 4

MEASUREMENT REPORT (Step 10) (7.68 Mcps TDD)

Information Element

Value/remark

Measurement identity

Check to see if set to 1

Measured Results

Check to see if it is absent

Measured Results on RACH

Check to see if it is absent

Additional Measured Results

Check to see if it is absent

Event Results

– CHOICE event result

Check to see if this IE is set to "Inter-frequency measurement event results"

– Inter-frequency event identity

Check to see if this IE is set to "2c"

– Inter-frequency cells

– Frequency info

– CHOICE mode

TDD

– UARFCN(Nt)

Check to see if set to the UARFCN of the frequency for cell 4

– Non frequency related measurement event results

– CHOICE Mode

Check to see if set to "TDD"

– Primary CCPCH info

– CHOICE Mode

Check to see if set to "TDD"

– CHOICE TDD option

Check to see if set to "7.68 Mcps TDD”

– CHOICE Sync Case

Check to see if set to " Sync Case 1”

– Timeslot

Check to see if it’s the same for cell 4 (S/B 0)

– Cell parameters Id

Check to see if it’s the same for cell 4

– SCTD indicator

Check to see if set to "FALSE”

8.4.1.2a.5 Test Requirement

After step 5 the UE shall not transmit any MEASUREMENT REPORT messages pertaining to the measurement of PCCPCH RSCP of cell 4.

After step 7 the UE shall transmit MEASUREMENT REPORT messages on uplink DCCH, reporting cell 4’s PCCPCH RSCP value at periodic time interval of 16 seconds in "inter-frequency cell measurement results" IE.

After step 9 the UE shall transmit only 1 MEASUREMENT REPORT message on the uplink DCCH. In this message, IE "inter-frequency cell measured results" shall be absent.

8.4.1.2b Measurement Control and Report: Inter-band measurement for transition from idle mode to CELL_DCH state (FDD)

8.4.1.2b.1 Definition

This test case is identical to test case 8.4.1.2 except that the cells belong to different frequency bands.

8.4.1.2b.2 Conformance requirement

Same conformance requirement as in clause 8.4.1.2.2.

8.4.1.2b.3 Test Purpose

Same test purpose as in clause 8.4.1.2.3 except that the cells belong to different frequency bands.

8.4.1.2b.4 Method of test

Initial Condition

Same initial conditions as in clause 8.4.1.2.4 except that cell 1 and cell 4 use UARFCNs selected from different frequency bands.

Related ICS/IXIT statements

– Compressed mode required yes/no- UE supports multiple bands simultaneously yes/no

Test Procedure

Same test procedure as in clause 8.4.1.2.4.

Note: If the UE supports more than 2 frequency bands, the test may be executed for various band combinations.

Expected Sequence

Same expected sequence as in clause 8.4.1.2.4.

Specific Message Content

Same as Specific Message Content in clause 8.4.1.2.4.

8.4.1.2b.5 Test Requirement

Same test requirement as in clause 8.4.1.2.5.

8.4.1.2c Measurement Control and Report: Inter-frequency measurement for transition from idle mode to CELL_DCH state (Cells belong to different frequency bands for LCR TDD)

8.4.1.2c.1 Definition

This test case is identical to test case 8.4.1.2a except that the cells belong to different frequency bands.

8.4.1.2c.2 Conformance requirement

Same conformance requirement as in clause 8.4.1.2a.2.

8.4.1.2c.3 Test Purpose

Same test purpose as in clause 8.4.1.2a.3 except that the cells belong to different frequency bands.

8.4.1.2c.4 Method of test

Initial Condition

Same initial conditions as in clause 8.4.1.2a.4 except that cell 1 and cell 4 use UARFCNs selected from different frequency bands.

Related ICS/IXIT statements

– Compressed mode required yes/no – UE supports multiple bands simultaneously yes/no

Test Procedure

Same test procedure as in clause 8.4.1.2a.4.

NOTE: If the UE supports more than 2 frequency bands, the test may be executed for various band combinations.

Expected Sequence

Same expected sequence as in clause 8.4.1.2a.4.

Specific Message Content

Same as Specific Message Content in clause 8.4.1.2a.4.

8.4.1.2c.5 Test Requirement

Same test requirement as in clause 8.4.1.2a.5.

8.4.1.3 Measurement Control and Report: Intra-frequency measurement for transition from idle mode to CELL_FACH state (FDD)

8.4.1.3.1 Definition

8.4.1.3.2 Conformance requirement

Upon transition from idle mode to CELL_FACH state, the UE shall:

1> begin or continue monitoring cells listed in the IE "intra-frequency cell info list" received in System Information Block type 12 (or System Information Block type 11).

In CELL_FACH state, the UE shall:

1> include a measurement report in the IE "Measured results on RACH", as specified in the IE "Intra-frequency reporting quantity for RACH reporting" and the IE "Maximum number of reported cells on RACH" in System Information Block type 12 (or "System Information Block Type 11" if "System Information Block Type 12" is not being broadcast);

1> include in the IE "Measured results on RACH" all requested reporting quantities for cells for which measurements are reported.

Upon transition from CELL_FACH to CELL_DCH state, the UE shall:

1> retrieve each set of measurement control information of measurement type "intra-frequency" stored in the variable MEASUREMENT_IDENTITY;

1> if the IE "measurement validity" for a measurement has been assigned the value "CELL_DCH:

2> resume the measurement reporting.

1> if no intra-frequency measurements applicable to CELL_DCH state are stored in the variable MEASUREMENT_IDENTITY:

2> continue monitoring the list of neighbouring cells assigned in the IE "intra-frequency cell info list" in System Information Block type 12 (or System Information Block type 11);

2> if the IE "intra-frequency measurement reporting criteria" was included in System Information Block type 12 (or System Information Block type 11):

3> send the MEASUREMENT REPORT message when reporting criteria in IE "Reporting information for state CELL_DCH" are fulfilled.

Reference

3GPP TS 25.331, clause 8.4.1.9.1, 8.4.1.7.1, 8.4.2.2.

8.4.1.3.3 Test Purpose

  1. To confirm that the UE begins or continues to monitor cells listed in IE "intra-frequency cell info list" of System Information Block type 11 or 12 messages after it has entered CELL_FACH state from idle mode.
  2. To confirm that the UE applies the reporting criteria stated in "intra-frequency measurement reporting criteria" IE in System Information Block Type 11 or 12 in a subsequent transition to CELL_DCH state.
  3. To confirm that the UE reports measured results on RACH messages, if it receives IE "Intra-frequency reporting quantity for RACH reporting" and IE "Maximum number of reported cells on RACH" from System Information Block Type 11 or 12 upon a transition from idle mode to CELL_FACH state.

8.4.1.3.4 Method of test

Initial Condition

System Simulator: 2 cells. Cell 1 and cell 2 are active.

SYSTEM INFORMATION BLOCK TYPE 1 (see specific message contents).

UE: "Registered idle mode on PS" (state 3) in cell 1 as specified in clause 7.4 of TS 34.108. If the UE supports both CS and PS domains, the initial UE state shall be "Registered idle mode on CS/PS" (state 7).

Test Procedure

Table 8.4.1.3-1 illustrates the downlink power to be applied for the 2 cells in this test case.

Table 8.4.1.3-1

Parameter

Unit

Cell 1

Cell 2

UTRA RF Channel Number

Mid Range Test Frequency

Mid Range Test Frequency

CPICH Ec

dBm/3.84 MHz

-60

-67

The UE is initially in idle mode and camps on cell 1. The System Information Block type 11 are modified compared to the default settings. In the System Information Block type 11 messages, reporting of CPICH RSCP is also required for intra-frequency reporting when transmitting RACH messages on cell 1.

SS prompts the operator to make an outgoing call for one of the traffic classes supported by the UE. SS and UE shall execute procedure P6. Next SS and UE shall execute procedure P10. Then SS and UE shall execute procedure P14. SS starts timer T305 and waits until timer T305 expires, the UE shall send a CELL UPDATE message on the CCCH which includes the measured value of cell 1’s CPICH RSCP in IE "Measured results on RACH". SS then replies with CELL UPDATE CONFIRM message on the downlink DCCH, without changing the physical channel resources.

SS transmits PHYSICAL CHANNEL RECONFIGURATION message, and allocates dedicated physical channels to the UE. The UE shall transit to CELL_DCH state and then send a MEASUREMENT REPORT message, correctly stating the measurement identity. The measurement identity indicated shall match the value that was previously broadcast on System Information Block type 11 messages when the UE was still in idle mode. The IE "Measured results" in the MEASUREMENT REPORT messages shall contain measured values of cell 2’s CPICH RSCP.

Expected Sequence

Step

Direction

Message

Comment

UE

SS

1

System Information Block type 1,

System Information Block type 11

The UE is in idle mode and camps onto cell 1. System Information Block type 1 and 11 to be transmitted are different from the default settings (see specific message contents)

2

SS executes procedure P6 (clause 7.4.2.2.2) specified in TS 34.108.

SS prompts the test operator to make an outgoing call.

3

SS executes procedure P10 (clause 7.4.2.4.2) specified in TS 34.108.

4

SS executes procedure P14 (clause 7.4.2.6.2) specified in TS 34.108.

5

Void

6

SS monitors the uplink DCCH to confirm that no MEASUREMENT REPORT messages are detected. SS waits for 5 minutes (for the expiry of T305 timer).

7

CELL UPDATE

This message shall contain IE "Measured results on RACH" reporting the measured CPICH RSCP for cell 1.

8

CELL UPDATE CONFIRM

SS does not change the physical channel configurations.

9

PHYSICAL CHANNEL RECONFIGURATION

SS assigns dedicated physical resources.

10

PHYSICAL CHANNEL RECONFIGURATION COMPLETE

UE shall transit to CELL_DCH state.

11

MEASUREMENT REPORT

UE shall begin to report cell 2’s CPICH RSCP value periodically at 16 seconds interval. The measurement identity shall match the one that is broadcast for use in CELL_DCH in SIB11 in step 1.

Specific Message Content

System Information Block type 1 (Step 1)

Use the same System Information Block Type 1 message as found in clause 6.1.0b of TS 34.108, with the following exceptions:

Information Element

Value/Remarks

UE Timers and constants in connected mode

– T305

5 minutes.

– T312

2

System Information Block type 11 (Step 1)

Use the same System Information Block Type 11 message as found in clause 6.1.0b of TS 34.108, with the following exceptions:

Information Element

Value/remark

SIB12 Indicator

FALSE

Measurement control system information

– Intra-frequency measurement system information

– Intra-frequency measurement identity

5

– Intra-frequency cell info list

– CHOICE intra-frequency cell removal

Not Present

– New intra-frequency cells

– Intra-frequency cell id

1

– Cell info

– Cell individual offset

Not Present

– Reference time difference to cell

Not present

– Read SFN Indicator

FALSE

– CHOICE mode

FDD

– Primary CPICH Info

– Primary Scrambling Code

Refer to clause titled "Default settings for cell No.1 (FDD)" in clause 6.1.4 of TS 34.108

– Primary CPICH TX power

Not Present

– TX Diversity Indicator

FALSE

– Cell selection and Re-selection info

Not present

– Intra-frequency cell id

2

– Cell info

– Cell individual offset

Not Present

– Reference time difference to cell

Not Present

– Read SFN Indicator

TRUE

– CHOICE mode

FDD

– Primary CPICH Info

– Primary Scrambling Code

Refer to clause titled "Default settings for cell No.2 (FDD)" in clause 6.1.4 of TS 34.108

– Primary CPICH TX power

Not Present

– TX Diversity Indicator

FALSE

– Cell selection and Re-selection info

– Qoffset1s,n

Not Present (Default is 0 dB)

– Qoffset2s,n

Not Present

– Maximum allowed UL TX power

0 dBm

– HCS neighbouring cell information

Not Present

– CHOICE Mode

FDD

– Qqualmin

-20dB

– Qrxlevmin

-58 (-115dBm)

– Cells for measurement

Not Present

– Intra-frequency reporting quantity for RACH reporting

– SFN-SFN observed time difference reporting indicator

No report

– CHOICE mode

FDD

– Measurement quantity

CPICH RSCP

– Maximum number of reported cells on RACH

Current cell

– Reporting information for state CELL_DCH

– Intra-frequency reporting quantity

– Reporting quantities for active set cells

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CHOICE mode

FDD

– CPICH Ec/No reporting indicator

TRUE

– CPICH RSCP reporting indicator

FALSE

– Pathloss reporting indicator

FALSE

– Reporting quantities for monitored set cells

– Cell synchronisation information reporting indicator

TRUE

– Cell identity reporting indicator

FALSE

– CHOICE mode

FDD

– CPICH Ec/No reporting indicator

FALSE

– CPICH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged mode RLC

– Periodic Reporting/Event Trigger Reporting Mode

Event trigger

– CHOICE report criteria

Intra-frequency measurement reporting criteria

– Parameters required for each event

– Intra-frequency event identity

1a

– Triggering condition 1

Not Present

– Triggering condition 2

Monitored set cells

– Reporting Range Constant

28 (14 dB)

– Cells forbidden to affect reporting range

Not Present

– W

0.0

– Hysteresis

2 (1.0 dB)

– Threshold used frequency

Not Present

– Reporting deactivation threshold

0

– Replacement activation threshold

Not Present

– Time to trigger

60 ms

– Amount of reporting

Infinity

– Reporting interval

16 seconds

– Reporting Cell Status

– CHOICE reported cell

Report cells within active and/or monitored set on used frequency or within active and/or monitored set on non-used frequency

– Maximum number of reported cells

2

CELL UPDATE (Step 7)

Information Element

Value/remark

U-RNTI

Check to see if set to same U-RNTI value assigned in the execution of procedure P6.

START list

Checked to see if this IE is present

AM_RLC error indication(RB2, RB3 or RB4)

FALSE

AM_RLC error indication(RB>4)

FALSE

Cell update cause

Check to see if set to ‘Periodical cell update’

Failure cause

Check to see if this IE is absent

RB timer indicator

– T314 expired

Checked to see if it is set to ‘FALSE’

– T315 expired

Checked to see if it is set to ‘FALSE’

Measured results on RACH

– Measurement result for current cell

– CHOICE measurement quantity

Check to see if set to ‘CPICH RSCP’

– CPICH RSCP

Checked to see if set to within an acceptable range.

– Measurement results for monitored cells

Checked to see if this IE is absent.

PHYSICAL CHANNEL RECONFIGURATION (Step 9) with the following exception:

Information Element

Value/remark

Downlink information for each radio links

– Choice mode

FDD

– Primary CPICH info

– Primary scrambling code

Ref. to the Default settings in clause 6.1 (FDD)

– PDSCH with SHO DCH info

Not Present

– PDSCH code mapping

Not Present

– Downlink DPCH info for each RL

– CHOICE mode

FDD

– Primary CPICH usage for channel estimation

Primary CPICH may be used

– DPCH frame offset

Set to value : Default DPCH Offset Value mod 38 400

– Secondary CPICH info

Not Present

– DL channelisation code

– Secondary scrambling code

Same value as used for Cell 1

– Spreading factor

Reference to clause 6.10 Parameter Set

– Code number

0

– Scrambling code change

Not present

Use the same message sub-type found in [9] TS 34.108 clause 9, which is entitled "Packet to CELL_DCH from CELL_FACH".

MEASUREMENT REPORT (Step 11)

Information Element

Value/remark

Measurement identity

Check to see if set to 5

Measured Results

– CHOICE measurement

Check to see if set to "Intra-frequency measured results list"

– Intra-frequency measurement results

– Cell measured results

– Cell Identity

Check to see if it is absent

– Cell synchronisation information

Check to see if this IE is absent

– Primary CPICH Info

– Primary Scrambling Code

Check to see if it’s the same code for cell 1

– CPICH Ec/No

Check to see if this IE is present

– CPICH RSCP

Check to see if this IE is absent

– Pathloss

Check to see if this IE is absent

– Cell measured results

– Cell Identity

Check to see if it is absent

– Cell synchronisation information

Check to see if this IE is present and includes IE COUNT-C-SFN frame difference

– Primary CPICH Info

Check to see if it’s the same code for cell 2

– Primary Scrambling Code

Check to see if this IE is absent

– CPICH Ec/No

Check to see if this IE is absent

– CPICH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

Measured Results on RACH

Check to see if this IE is absent

Event Results

– CHOICE event result

Check to see if set to "Intra-frequency measurement event results"

– Intra-frequency event identity

Check to see if set to "1a"

– Cell measurement event results

– CHOICE Mode

Check to see if set to "FDD"

– Primary CPICH info

– Primary Scrambling Code

Check to see if set to the scrambling code of cell 2

8.4.1.3.5 Test Requirement

After step 5 the UE shall not transmit any MEASUREMENT REPORT messages on the uplink DCCH.

After step 6 the UE shall initiate cell update procedure by transmitting CELL UPDATE message on CCCH. In this message, IE "cell update cause" shall be set to "periodic cell update". It shall include IE "measured results on RACH", containing the measurement value for cell 1’s CPICH RSCP.

After step 10 the UE shall transmit MEASUREMENT REPORT messages at 16 seconds interval. In these messages, cell 2’s CPICH RSCP value shall be reported in IE "Measured results". The IE "measurement identity" in this message shall match the IE "Intra-frequency measurement identity" found in System Information Block type 11 messages transmitted in step 1. The MEASUREMENT REPORT messages shall also contain IE "Event results", indicating that intra-frequency event "1a" has triggered in the UE.

8.4.1.3a Measurement Control and Report: Intra-frequency measurement for transition from idle mode to CELL_FACH state (TDD)

8.4.1.3a.1 Definition

8.4.1.3a.2 Conformance requirement

The UE shall obey the follow rules for different measurement types after transiting from idle mode to CELL_FACH state:

Upon transition from idle mode to CELL_FACH state, the UE shall:

1> begin or continue monitoring cells listed in the IE "intra-frequency cell info list" received in System Information Block type 12 (or System Information Block type 11, according to subclause 8.1.1.6.11, TS 25.331).

The purpose of the measurement reporting procedure is to transfer measurement results from the UE to UTRAN.

In CELL_FACH state, the UE shall:

1> transmit a MEASUREMENT REPORT message on the uplink DCCH when the reporting criteria stored in variable MEASUREMENT_IDENTITY are met for any ongoing traffic volume measurement or UE positioning measurement that is being performed in the UE;

1> include a measurement report in the IE "Measured results on RACH", as specified in the IE "Intra-frequency reporting quantity for RACH reporting" and the IE "Maximum number of reported cells on RACH" in System Information Block type 12 (or "System Information Block Type 11" if "System Information Block Type 12" is not being broadcast);

1> include in the IE "Measured results on RACH" all requested reporting quantities for cells for which measurements are reported.

In TDD, if the Radio Bearer associated with the MEASUREMENT_IDENTITY fulfilling the reporting criteria for an ongoing traffic volume measurement is mapped on transport channel of type USCH, the UE shall:

1> initiate the "PUSCH CAPACITY REQUEST" procedure instead of transmitting a MEASUREMENT REPORT (TDD Only).

For the measurement, which triggered the MEASUREMENT REPORT message, the UE shall:

1> set the IE "measurement identity" to the measurement identity, which is associated with that measurement in variable MEASUREMENT_IDENTITY;

1> set the IE "measured results" to include measurements according to the IE "reporting quantity" of that measurement stored in variable MEASUREMENT_IDENTITY; and

2> if all the reporting quantities are set to "false":

3> not set the IE "measured results".

1> set the IE "Measured results" in the IE "Additional measured results" according to the IE "reporting quantity" for all measurements associated with the measurement identities included in the "Additional measurements list" stored in variable MEASUREMENT_IDENTITY of the measurement that triggered the measurement report; and

2> if more than one additional measured results are to be included:

3> include only the available additional measured results, and sort them in ascending order according to their IE "measurement identity" in the MEASUREMENT REPORT message.

1> if the MEASUREMENT REPORT message was triggered by an event (i.e. not a periodical report):

2> set the IE "Event results" according to the event that triggered the report.

The UE shall:

1> transmit the MEASUREMENT REPORT message on the uplink DCCH using either AM or UM RLC according to the stored IE "measurement reporting mode" associated with the measurement identity that triggered the report.

When the MEASUREMENT REPORT message has been submitted to lower layers for transmission:

1> the procedure ends.

Upon reception of a MEASUREMENT CONTROL message the UE shall perform actions specified in subclause 8.6 in TS 25.331 unless otherwise specified below.

The UE shall:

1> read the IE "Measurement command";

1> if the IE "Measurement command" has the value "setup":

2> store this measurement in the variable MEASUREMENT_IDENTITY according to the IE "measurement identity", first releasing any previously stored measurement with that identity if that exists;

2> if the measurement type is quality, UE internal, intra-frequency, inter-frequency or inter-RAT:

3> if, according to its measurement capabilities, the UE does not require compressed mode to perform the measurements:

4> if the measurement is valid in the current RRC state of the UE:

5> begin measurements according to the stored control information for this measurement identity.

2> for any other measurement type:

3> if the measurement is valid in the current RRC state of the UE:

4> begin measurements according to the stored control information for this measurement identity.

1> if the IE "measurement command" has the value "release":

2> terminate the measurement associated with the identity given in the IE "measurement identity";

2> clear all stored measurement control information related associated to this measurement identity in variable MEASUREMENT_IDENTITY.

1> clear the entry for the MEASUREMENT CONTROL message in the table "Accepted transactions" in the variable TRANSACTIONS;

1> if the UE "Additional Measurement List" is present:

2> if the received measurement configuration in this MEASUREMENT CONTROL message, or any measurement identities in the "Additional Measurement List" do not all have the same validity:

3> set the variable CONFIGURATION_INCOMPLETE to TRUE.

1> and the procedure ends.

Reference

TS 25.331, clauses 8.4.1.9.1, 8.4.2, 8.4.1.3

8.4.1.3a.3 Test Purpose

1. To confirm that the UE begins or continues to monitor cells listed in IE "intra-frequency cell info list" of System Information Block type 11 or 12 messages after it has entered CELL_FACH state from idle mode.

2. To confirm that the UE applies the reporting criteria stated in "intra-frequency measurement reporting criteria" IE in System Information Block Type 11 or 12 in a subsequent transition to CELL_DCH state.

3. To confirm that the UE reports measured results on RACH messages, if it receives IE "Intra-frequency reporting quantity for RACH reporting" and IE "Maximum number of reported cells on RACH" from System Information Block Type 11 or 12 upon a transition from idle mode to CELL_FACH state.

8.4.1.3a.4 Method of test

Initial Condition

System Simulator: 2 cells. Cell 1 and cell 2 are active.

UE: "Registered idle mode on PS" (state 3) in cell 1 as specified in clause 7.4 of TS 34.108. If the UE supports both CS and PS domains, the initial UE state shall be "Registered idle mode on CS/PS" (state 7).

Test Procedure

Table 8.4.1.3a-1 illustrates the downlink power to be applied for the 2 cells in this test case.

Table 8.4.1.3a-1

Parameter

Unit

Cell 1

Cell 2

UTRA RF Channel Number

Mid Range Test Frequency

Mid Range Test Frequency

PCCPCH RSCP

dBm

-64

-74

The UE is initially in idle mode and camps on cell 1. The System Information Block type 11 are modified compared to the default settings to prevent reporting of "Cell synchronisation information" and also to include cell 2 into the IE "intra-frequency cell info list".

SS prompts the operator to make an outgoing call for one of the traffic classes supported by the UE. SS and UE shall execute procedure P6. Next SS and UE shall execute procedure P10. Then SS and UE shall execute procedure P14. SS starts timer T305 and waits until timer T305 expires, the UE shall send a CELL UPDATE message on the CCCH which includes the measured value of cell 1’s PCCPCH RSCP in IE "Measured results on RACH". SS then replies with CELL UPDATE CONFIRM message on the downlink DCCH, without changing the physical channel resources.

SS transmits PHYSICAL CHANNEL RECONFIGURATION message, and allocates dedicated physical channels to the UE. The UE shall transit to CELL_DCH state and then send a MEASUREMENT REPORT message, correctly stating the measurement identity. The measurement identity indicated shall match the value that was previously broadcast on System Information Block type 11 messages when the UE was still in idle mode. The IE "Measured results" in the MEASUREMENT REPORT messages shall contain measured values of cell 1, 2’s PCCPCH RSCP.

NOTE: The Radio Bearer associated with the MEASUREMENT_IDENTITY fulfilling the reporting criteria for an ongoing traffic volume measurement must not be mapped on transport channel of type USCH

Expected Sequence

Step

Direction

Message

Comment

UE

SS

1

System Information Block type 1,

System Information Block type 11

The UE is in idle mode and camps onto cell 1. System Information Block type 1 and 11 to be transmitted are different from the default settings (see specific message contents)

2

SS executes procedure P6 (clause 7.4.2.2.2) specified in TS 34.108.

SS prompts the test operator to make an outgoing call.

3

SS executes procedure P10 (clause 7.4.2.4.2) specified in TS 34.108.

UE reaches PS-DCCH FACH

4

SS executes procedure P14 (clause 7.4.2.6.2) specified in TS 34.108.

UE reaches PS-DCCH+DTCH FACH

5

SS monitors the uplink DCCH to confirm that no MEASUREMENT REPORT messages are detected. SS waits for 5 minutes (for the expiry of T305 timer).

6

CELL UPDATE

This message shall contain IE "Measured results on RACH" reporting the measured PCCPCH RSCP for cell 1.

7

CELL UPDATE CONFIRM

SS does not change the physical channel configurations.

8

PHYSICAL CHANNEL RECONFIGURATION

SS assigns dedicated physical resources.

9

PHYSICAL CHANNEL RECONFIGURATION COMPLETE

UE shall transit to CELL_DCH state.

10

MEASUREMENT REPORT

UE shall begin to report cell 1,2’s PCCPCH RSCP value. The measurement identity shall match the one that is broadcast for use in CELL_DCH in SIB11 in step 1.

Specific Message Content

System Information Block type 1 (Step 1)

Information Element

Value/Remarks

UE Timers and constants in connected mode

– T305

5 minutes.

System Information Block type 11 (Step 1)

Information Element

Value/remark

SIB12 indicator

FALSE

FACH measurement occasion info

Not Present

Measurement control system information

– Use of HCS

Not used

– Intra-frequency measurement system information

– Intra-frequency measurement identity

5

– Intra-frequency cell info list

– CHOICE intra-frequency cell removal

Not Present

– New intra-frequency cells

– Intra-frequency cell id

1

– Cell info

– Cell individual offset

Not Present

– Reference time difference to cell

Not present

– Read SFN Indicator

FALSE

– CHOICE mode

TDD

– Primary CCPCH Info

Refer to clause titled "Default settings for cell No.1 (TDD)" in clause 6.1.4 of TS 34.108

– Cell selection and Re-selection info

Not present

– Intra-frequency cell id

2

– Cell info

– Cell individual offset

Not Present

– Reference time difference to cell

Not Present

– Read SFN Indicator

TRUE

– CHOICE mode

TDD

– Primary CCPCH Info

Refer to clause titled "Default settings for cell No.2 (TDD)" in clause 6.1.4 of TS 34.108

– Cell selection and Re-selection info

– Qoffset1s,n

Not Present (Default is 0 dB)

– Maximum allowed UL TX power

0 dBm

– HCS neighbouring cell information

Not Present

– CHOICE Mode

TDD

– Qrxlevmin

-52 (-103dBm)

– Cells for measurement

Not Present

– Intra-frequency Measurement quantity

– Filter Coefficient

Not Present

– CHOICE Mode

TDD

– Measurement quantity list

– Measurement quantity

PCCPCH RSCP

– Intra-frequency reporting quantity for RACH reporting

– SFN-SFN observed time difference reporting indicator

No report

– CHOICE mode

TDD

– Reporting quantity

PCCPCH RSCP

– Maximum number of reported cells on RACH

Current cell

– Reporting information for state CELL_DCH

– Intra-frequency reporting quantity

– Reporting quantities for active set cells

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CHOICE mode

TDD

– PCCPCH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting quantities for monitored set cells

– Cell synchronisation information reporting indicator

TRUE

– Cell identity reporting indicator

FALSE

– CHOICE mode

TDD

– Timeslot ISCP reporting indicator

FALSE

– Proposed TGSN Reporting required

FALSE

– PCCPCH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting quantities for detected set cells

Not present

– Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged mode RLC

– Periodic Reporting/Event Trigger Reporting Mode

Periodical reporting

– CHOICE report criteria

Periodic reporting criteria

– Amount of reporting

Infinity

– Reporting interval

64 seconds

– Inter-frequency measurement system information

Not Present

– Traffic volume measurement system information

Not Present

CELL UPDATE (Step 6)

Information Element

Value/remark

U-RNTI

Check to see if set to same U-RNTI value assigned in the execution of procedure P6.

START list

Checked to see if this IE is present

AM_RLC error indication(RB2, RB3 or RB4)

FALSE

AM_RLC error indication(RB>4)

FALSE

Cell update cause

Check to see if set to ‘Periodical cell update’

Failure cause

Check to see if this IE is absent

Measured results on RACH

– Measurement result for current cell

– CHOICE mode

TDD

– Primary CCPCH RSCP

Checked to see if set to within an acceptable range.

– Measurement results for monitored cells

Checked to see if this IE is absent.

PHYSICAL CHANNEL RECONFIGURATION (Step 8)

Use the same message sub-type found in [9] TS 34.108 clause 9, which is entitled "Packet to CELL_DCH from CELL_FACH".

MEASUREMENT REPORT (Steps 10)

Information Element

Value/remark

Measurement identity

Check to see if set to 1

Measured Results

– CHOICE measurement

Check to see if set to "Intra-frequency measured results list"

– Intra-frequency measurement results

– Cell measured results

– Cell Identity

Check to see if it is absent

– Cell synchronisation information

Check to see if this IE is absent

– CHOICE mode

TDD

– cell parameters identity

Check to see if it’s the same code for cell 1

– proposed TGSN

Check to see if this IE is absent

– PCCPCH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

– timeslotISCP_List

Check to see if this IE is absent

– Cell measured results

– Cell Identity

Check to see if this IE is absent

– Cell synchronisation information

Check to see if this IE is absent

– CHOICE mode

TDD

– cell parameters identity

Check to see if it’s the same code for cell 2

– proposed TGSN

Check to see if this IE is absent

– PCCPCH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

– timeslotISCP_List

Check to see if this IE is absent

Measured Results on RACH

Check to see if this IE is absent

Additional measured results

Check to see if this IE is absent

Event Results

Check to see if this IE is absent

8.4.1.3a.5 Test Requirement

After step 5 the UE shall not transmit any MEASUREMENT REPORT messages on the uplink DCCH.

After step 6 the UE shall initiate cell update procedure by transmitting CELL UPDATE message on CCCH. In this message, IE "cell update cause" shall be set to "periodic cell update". It shall include IE "measured results on RACH", containing the measurement value for cell 1’s PCCPCH RSCP.

After step 9 the UE shall transmit MEASUREMENT REPORT messages. In these messages, cell 1,2’s PCCPCH RSCP value shall be reported in IE "Measured results". The IE "measurement identity" in this message shall match the IE "Intra-frequency measurement identity" found in System Information Block type 11 messages transmitted in step 1. The MEASUREMENT REPORT messages shall not contain IE "Event results".

8.4.1.4 Measurement Control and Report: Inter-frequency measurement for transition from idle mode to CELL_FACH state (FDD)

8.4.1.4.1 Definition

8.4.1.4.2 Conformance requirement

Upon transition from idle mode to CELL_FACH state, the UE shall:

1> begin or continue monitoring cells listed in the IE "inter-frequency cell info list" received in System Information Block type 12 (or System Information Block type 11);

Reference

3GPP TS 25.331, clause 8.4.1.9.2

8.4.1.4.3 Test Purpose

1. To confirm that the UE begins to monitor the list of cells assigned in the IE "inter-frequency cell info list" in System Information Block type 11 or 12 messages, after it enters CELL_FACH state from idle mode. However, it shall not transmit any MEASUREMENT REPORT messages to report measured results for inter-frequency cells.

8.4.1.4.4 Method of test

Initial Condition

System Simulator: 2 cells – Cell 1 and cell 4 are active.

UE: "Registered idle mode on PS" (state 3) in cell 1 as specified in clause 7.4 of TS 34.108, depending on the CN domain supported by the UE. If the UE supports both CS and PS domains, the initial UE state shall be "Registered idle mode on CS/PS" (state 7).

Test Procedure

Table 8.4.1.4-1 illustrates the downlink power to be applied for the 2 cells at various time instants of the test execution. Columns marked "T0" denote the initial conditions, while columns marked "T1 are to be applied subsequently. The exact instants on which these values shall be applied are described in the texts in this clause.

Table 8.4.1.4-1

Parameter

Unit

Cell 1

Cell 4

T0

T1

T0

T1

UTRA RF Channel Number

Mid Range Test Frequency

High Range Test Frequency

CPICH Ec

dBm/3.84 MHz

-60

-75

-75

-60

The UE is initially at idle mode and has selected cell 1 for camping. The System Information Block type 11 messages are modified with respect to the default settings to prevent reporting of "Cell synchronisation information" and also to include cell 4 into the "inter-frequency cell list" IE.

SS prompts the operator to make an outgoing call of a supported traffic class. SS and UE shall execute procedure P6. Next SS and UE shall execute procedure P10. Then SS and UE shall execute procedure P14. The UE shall not transmit any MEASUREMENT REPORT messages, which pertain to measurement readings for inter-frequency cells belonging to the monitored set. SS re-adjusts its downlink power settings according to columns marked "T1" in table 8.4.1.4-1. This is expected to trigger a cell reselection in the UE. The UE shall send CELL UPDATE message to cell 4 in order to report this event. Upon receiving this message, SS replies with the CELL UPDATE CONFIRM message, which includes IE "New C-RNTI", on the downlink DCCH. UE shall then reply with a UTRAN MOBILITY INFORMATION CONFIRM message.

NOTE: If the UE fails the test because of a failure to reselect to a right cell, then the operator may re-run the test.

Expected Sequence

Step

Direction

Message

Comment

UE

SS

1

System Information Block type 11

The UE is in idle mode in cell 1. System Information Block type 11 to be transmitted is different from the default settings (see specific message contents)

2

SS executes procedure P6 (clause 7.4.4.4.2) specified in TS 34.108.

3

SS executes procedure P10 (clause 7.4.2.4.2) specified in TS 34.108.

4

SS executes procedure P6 (clause 7.4.4.4.2) specified in TS 34.108.

5

Void

6

SS checks to see that no MEASUREMENT REPORT messages are received.

7

SS reconfigures the downlink transmission power, according to columns "T1" of table 8.4.1.4-1.

8

CELL UPDATE

UE shall detect that cell 4 has become stronger than cell 1. It sends this message after re-selecting to cell 4

9

CELL UPDATE CONFIRM

Use message content.

10

UTRAN MOBILITY INFORMATION CONFIRM

Specific Message Content

All messages indicated below shall use the same content as described in default message content, with the following exceptions:

System Information Block type 11 (Step 1)

Information Element

Value/remark

SIB12 Indicator

FALSE

FACH measurement occasion info

– FACH Measurement occasion cycle length coefficient

2

– Inter-frequency FDD measurement indicator

TRUE

– Inter-frequency TDD measurement indicator

FALSE

– Inter-RAT measurement indicators

Not Present

Measurement control system information

– Intra-frequency measurement system information

Not Present

– Inter-frequency measurement system information

– Inter-frequency cell info list

– CHOICE inter-frequency cell removal

No inter-frequency cells removed

– New inter-frequency cells

– Inter-frequency cell id

4

– Frequency info

– CHOICE mode

FDD

– UARFCN uplink (Nu)

Not present

Absence of this IE is equivalent to apply the default duplex distance defined for the operating frequency according to 25.101

– UARFCN downlink (Nd)

Reference to table 6.1.2 of TS 34.108 for Cell 4

– Cell info

– Cell individual offset

Not Present

– Reference time difference to cell

Not Present

– Read SFN Indicator

FALSE

– CHOICE mode

FDD

– Primary CPICH Info

– Primary Scrambling Code

Refer to clause titled "Default settings for cell No.4 (FDD)" in clause 6.1.4 of TS 34.108

– Primary CPICH TX power

Not Present

– TX Diversity Indicator

FALSE

– Cell selection and re-selection info

– Qoffsets,n

0 dB

– Maximum allowed UL TX power

0 dBm

– HCS neighbouring cell information

Not Present

– CHOICE Mode

FDD

– Qqualmin

-20dB

– Qrxlevmin

-58 (-115dBm)

– Inter-RAT measurement system information

Not Present

– Traffic volume measurement system information

Not Present

CELL UPDATE (Step 8)

Information Element

Value/remark

U-RNTI

Check to see if set to same U-RNTI assigned during the execution of procedure P6.

Cell update cause

Check to see if it is set to "Cell Reselection"

Protocol error info

Check to see if it is absent or set to FALSE

Measured results on RACH

Check to see if it is absent

Protocol error information

Check to see if it is absent

CELL UPDATE CONFIRM (Step 9)

Use the message sub-type in default message content defined in Annex A, with the following exceptions.

Information Element

Value/Remarks

New C-RNTI

‘1010 1010 1010 1010’

UTRAN MOBILITY INFORMATION CONFIRM (Step 10)

Only the message type is checked.

8.4.1.4.5 Test Requirement

After step 5 the UE shall not transmit any MEASUREMENT REPORT messages pertaining to any measurement quantities for cell 4.

After step 7 the UE shall reselect to cell 4 and transmit a CELL UPDATE message on the uplink CCCH of cell 4.

After step 9, the UE shall transmit a UTRAN MOBILITY INFORMATION CONFIRM message on uplink DCCH AM RLC.

8.4.1.4a Measurement Control and Report: Inter-frequency measurement for transition from idle mode to CELL_FACH state (TDD)

8.4.1.4a.1 Definition

8.4.1.4a.2 Conformance requirement

Upon transition from idle mode to CELL_FACH state, the UE shall:

1> begin or continue monitoring cells listed in the IE "inter-frequency cell info list" received in System Information Block type 12 (or System Information Block type 11);

Reference

3GPP TS 25.331, clause 8.4.1.9.2

8.4.1.4a.3 Test Purpose

1. To confirm that the UE begins to monitor the list of cells assigned in the IE "inter-frequency cell info list" in System Information Block type 11 or 12 messages, after it enters CELL_FACH state from idle mode. However, it shall not transmit any MEASUREMENT REPORT messages to report measured results for inter-frequency cells.

8.4.1.4a.4 Method of test

Initial Condition

System Simulator: 2 cells – Cell 1 and cell 4 are active.

UE: "Registered idle mode on PS" (state 3) in cell 1 as specified in clause 7.4 of TS 34.108, depending on the CN domain supported by the UE. If the UE supports both CS and PS domains, the initial UE state shall be "Registered idle mode on CS/PS" (state 7).

Test Procedure

Table 8.4.1.4a-1 illustrates the downlink power to be applied for the 2 cells at various time instants of the test execution. Columns marked "T0" denote the initial conditions, while columns marked "T1 are to be applied subsequently. The exact instants on which these values shall be applied are described in the texts in this clause.

Table 8.4.1.4a-1

Parameter

Unit

Cell 1

Cell 4

T0

T1

T0

T1

UTRA RF Channel Number

Mid Range Test Frequency

High Range Test Frequency

PCCPCH RSCP

dBm

-60

-75

-75

-60

The UE is initially at idle mode and has selected cell 1 for camping. The System Information Block type 11 messages are modified with respect to the default settings to prevent reporting of "Cell synchronisation information" and also to include cell 4 into the "inter-frequency cell list" IE.

SS prompts the operator to make an outgoing call of a supported traffic class. SS and UE shall execute procedure P6. Next SS and UE shall execute procedure P10. Then SS and UE shall execute procedure P14. The UE shall not transmit any MEASUREMENT REPORT messages, which pertain to measurement readings for inter-frequency cells belonging to the monitored set. SS re-adjusts its downlink power settings according to columns marked "T1" in table 8.4.1.4a-1. This is expected to trigger a cell reselection in the UE. The UE shall send CELL UPDATE message to cell 4 in order to report this event. Upon receiving this message, SS replies with the CELL UPDATE CONFIRM message, which includes IE "New C-RNTI", on the downlink DCCH. UE shall then reply with a UTRAN MOBILITY INFORMATION CONFIRM message.

NOTE: If the UE fails the test because of a failure to reselect to a right cell, then the operator may re-run the test.

Expected Sequence

Step

Direction

Message

Comment

UE

SS

1

System Information Block type 11

The UE is in idle mode in cell 1. System Information Block type 11 to be transmitted is different from the default settings (see specific message contents)

2

SS executes procedure P6 (clause 7.4.4.4.2) specified in TS 34.108.

3

SS executes procedure P10 (clause 7.4.2.4.2) specified in TS 34.108.

4

SS executes procedure P6 (clause 7.4.4.4.2) specified in TS 34.108.

5

Void

6

SS checks to see that no MEASUREMENT REPORT messages are received.

7

SS reconfigures the downlink transmission power, according to columns "T1" of table 8.4.1.4a-1.

8

CELL UPDATE

UE shall detect that cell 4 has become stronger than cell 1. It sends this message after re-selecting to cell 4

9

CELL UPDATE CONFIRM

Use message content.

10

UTRAN MOBILITY INFORMATION CONFIRM

Specific Message Content

All messages indicated below shall use the same content as described in TS 34.108 clause 9, with the following exceptions:

System Information Block type 11 (Step 1)

Information Element

Value/remark

SIB12 Indicator

FALSE

FACH measurement occasion info

– FACH Measurement occasion cycle length coefficient

2

– Inter-frequency FDD measurement indicator

FALSE

– Inter-frequency TDD measurement indicator

TRUE

– Inter-RAT measurement indicators

Not Present

Measurement control system information

– Intra-frequency measurement system information

Not Present

– Inter-frequency measurement system information

– Inter-frequency cell info list

– CHOICE inter-frequency cell removal

No inter-frequency cells removed

– New inter-frequency cells

– Inter-frequency cell id

4

– Frequency info

– CHOICE mode

TDD

– UARFCN (Nt)

Reference to table 6.1.4 of TS 34.108 for Cell 4

– Cell info

– Cell individual offset

Not Present

– Reference time difference to cell

Not Present

– Read SFN Indicator

FALSE

– CHOICE mode

TDD

– Primary CCPCH Info

Refer to clause titled "Default settings for cell No.4 (TDD)" in clause 6.1.4 of TS 34.108

– Primary CCPCH TX power

Not Present

– Timeslot list

Not Present

– Cell selection and re-selection info

– Qoffsets,n

0 dB

– Maximum allowed UL TX power

0 dBm

– HCS neighbouring cell information

Not Present

– CHOICE Mode

TDD

– Qrxlevmin

-52 (-103 dBm)

– Inter-RAT measurement system information

Not Present

– Traffic volume measurement system information

Not Present

CELL UPDATE (Step 8)

Information Element

Value/remark

U-RNTI

Check to see if set to same U-RNTI assigned during the execution of procedure P6.

Cell update cause

Check to see if it is set to "Cell Reselection"

Measured results on RACH

Check to see if it is absent

CELL UPDATE CONFIRM (Step 9)

Use the message sub-type in default message content defined in Annex A, with the following exceptions.

Information Element

Value/Remarks

New C-RNTI

‘1010 1010 1010 1010’

UTRAN MOBILITY INFORMATION CONFIRM (Step 10)

Only the message type is checked.

8.4.1.4a.5 Test Requirement

After step 5 the UE shall not transmit any MEASUREMENT REPORT messages pertaining to any measurement quantities for cell 4.

After step 7 the UE shall reselect to cell 4 and transmit a CELL UPDATE message on the uplink CCCH of cell 4.

After step 9, the UE shall transmit a UTRAN MOBILITY INFORMATION CONFIRM message on uplink DCCH AM RLC.

8.4.1.5 Measurement Control and Report: Intra-frequency measurement for transition from CELL_DCH to CELL_FACH state (FDD)

8.4.1.5.1 Definition

8.4.1.5.2 Conformance requirement

Upon transition from CELL_DCH to CELL_FACH/CELL_PCH/URA_PCH state, the UE shall:

1> stop intra-frequency type measurement reporting;

1> if the transition is due to a reconfiguration message which included the IE "Primary CPICH info" (for FDD) or "Primary CCPCH info" (for TDD), and the UE selects a cell other than that indicated by this IE; or

1> if the transition is due to a reconfiguration message which does not include the IE "Primary CPICH info" (for FDD) or "Primary CCPCH info" (for TDD); or

1> if the transition is not due to a reconfiguration message:

2> delete the measurements of type intra-frequency associated with the variable MEASUREMENT_IDENTITY.

1> begin monitoring cells listed in the IE "intra-frequency cell info list" received in System Information Block type 12 (or System Information Block type 11, according to subclause 8.1.1.6.11 in [8] TS 25.331).

Upon transition from CELL_FACH to CELL_DCH state, the UE shall:

1> retrieve each set of measurement control information of measurement type "intra-frequency" stored in the variable MEASUREMENT_IDENTITY;

1> if the IE "measurement validity" for a measurement has been assigned the value "CELL_DCH:

2> resume the measurement reporting.

1> if no intra-frequency measurements applicable to CELL_DCH state are stored in the variable MEASUREMENT_IDENTITY:

2> continue monitoring the list of neighbouring cells assigned in the IE "intra-frequency cell info list" in System Information Block type 12 (or System Information Block type 11, according to subclause 8.1.1.6.11 in [8] TS 25.331);

2> if the IE "intra-frequency measurement reporting criteria" was included in System Information Block type 12 (or System Information Block type 11, according to subclause 8.1.1.6.11 in [8] TS 25.331):

3> send the MEASUREMENT REPORT message when reporting criteria in IE "Reporting information for state CELL_DCH" are fulfilled.

Reference

3GPP TS 25.331, clause 8.4.1.6.1, 8.4.1.7.1

8.4.1.5.3 Test Purpose

1. To confirm that the UE stops performing intra-frequency measurement reporting specified in a MEASUREMENT CONTROL message, when it moves from CELL_DCH state to CELL_FACH state.

2. To confirm that the UE reads the System Information Block type 11 or 12 messages when it enters CELL_FACH state from CELL_DCH state, and starts to monitor the cells listed in the IE "intra-frequency cell info list".

3 To confirm that the UE performs measurements on uplink RACH transmissions and appends the measured results in RACH messages, when it receives IE "intra-frequency reporting quantity for RACH reporting" and IE "Maximum number of reported cells on RACH" in the System Information Block type 11 or 12 messages.

4. To confirm that the UE applies the reporting criteria in IE "intra-frequency reporting criteria" in System Information Block Type 11 or 12 messages following a state transition from CELL_FACH to CELL_DCH, if no intra-frequency measurements applicable to CELL_DCH are stored.

8.4.1.5.4 Method of test

Initial Condition

System Simulator: 3 cells – Cell 1 and cell 2 are active, while cell 3 is switched off..

SYSTEM INFORMATION BLOCK TYPE 1 (see specific message contents).

UE: PS-DCCH+DTCH_DCH (state 6-10) in cell 1 as specified in clause 7.4 of TS 34.108.

Related ICS/IXIT statements

– PS Supported yes/no

Specific Message Contents

For system information block 11 of Cell 1 (gives IE’s which are different from defaults given in 34.108 subclause 6.1) to be transmitted before idle update preamble.

System Information Block type 11

Use the same message sub-type found in clause 6.1 of TS 34.108, with the following exception:

Information Element

Value/remark

SIB12 indicator

FALSE

FACH measurement occasion info

Not Present

Measurement control system information

– Use of HCS

Not used

– Cell selection and reselection quality measure

CPICH RSCP

– Intra-frequency measurement system information

– Intra-frequency measurement identity

Not present

– Intra-frequency cell info list

– CHOICE intra-frequency cell removal

Not present

– New intra-frequency cells

– Intra-frequency cell id

1

– Cell info

– Cell individual offset

Not present

– Reference time difference to cell

Not present

– Read SFN Indicator

FALSE

– CHOICE mode

FDD

– Primary CPICH Info

– Primary Scrambling Code

Refer to clause titled "Default settings for cell No.1 (FDD)" in clause 6.1.4 of TS 34.108

– Primary CPICH TX power

Not Present

– TX Diversity Indicator

FALSE

– Cell selection and Re-selection info

Not present

– Cells for measurement

Not Present

-Intra-frequency measurement quantity

Not Present

-Intra-frequency reporting quantity for RACH reporting

Not Present

-Maximum number of reported cells on RACH

Not Present

-Reporting information for state CELL_DCH

Not Present

– Inter-frequency measurement system information

Not Present

– Inter-RAT measurement system information

Not Present

– Traffic volume measurement system information

Not Present

Test Procedure

Table 8.4.1.5-1 illustrates the downlink power to be applied for the 3 cells at various time instants of the test execution. Columns marked "T0" denote the initial conditions, while columns marked "T1 are to be applied subsequently. The exact instants on which these values shall be applied are described in the texts in this clause.

Table 8.4.1.5-1

Parameter

Unit

Cell 1

Cell 2

Cell 3

T0

T1

T0

T1

T0

T1

UTRA RF Channel Number

Mid Range Test Frequency

Mid Range Test Frequency

Mid Range Test Frequency

CPICH Ec

dBm/3.84 MHz

-60

-60

-70

-85

OFF

-70

The UE is initially in CELL_DCH state. The System Information Block type 11 message is modified compared to the default message contents, in order to prevent the reporting of "Cell synchronisation information". No measurement to be applied by the UE in CELL_DCH state is specified in any of the System Information Block type 11 or 12 messages.

SS sends a MEASUREMENT CONTROL message to UE. In this message, the SS requests the establishment of an intra-frequency measurement for the measurement of cell 2’s CPICH RSCP. At the same time, reporting of CPICH RSCP values of active set cells and monitored set cells are requested with the reporting criteria set to "periodic reporting" and "reporting interval" set to 16 seconds. The UE shall start transmitting MEASUREMENT REPORT messages at 16 seconds interval corresponding to the requested reporting event.

SS transmits PHYSICAL CHANNEL RECONFIGURATION message to move the UE to CELL_FACH. After receiving this message, the UE shall reconfigure itself and reply with a PHYSICAL CHANNEL RECONFIGURATION COMPLETE message on RACH. SS starts T305 timer and SS monitors the uplink channels to verify that no MEASUREMENT REPORT messages are received.

SS reconfigures itself according to the settings in columns marked "T1" in table 8.4.1.5-1. SS transmits System Information Block type 12 messages in cell 1, which include cell 3 into the IE "intra-frequency cell info list" and modifies SIB11 to indicate that SIB12 is now being broadcast. IEs "Intra-frequency reporting quantity for RACH Reporting" and IE "Maximum number of Reported cells on RACH" are also specified in the System Information Type 12 messages. Event type 1a reporting criterion is specified for intra-frequency measurements. SS transmit SYSTEM INFORMATION CHANGE INDICATION message to UE. SS waits until T305 has expired. The UE shall respond with a CELL UPDATE message, which comprises IE "Measured results on RACH" to report the readings of CPICH RSCP for cell 1 and cell 3. SS replies with CELL UPDATE CONFIRM message on the downlink DCCH. This message does not change the physical resources nor allocate any new RNTI identities. SS transmits PHYSICAL CHANNEL RECONFIGURATION message again, and configures dedicated physical channel for both uplink and downlink directions. The UE shall send PHYSICAL CHANNEL RECONFIGURATION COMPLETE message and return to CELL_DCH state. SS listens to the uplink DCCH for MEASUREMENT REPORT messages.

SS shall receive the MEASUREMENT REPORT messages at 500 milliseconds interval.

SS verifies that it includes CPICH RSCP values of the cells 1and 3 in IE "Cell measured results" and the triggering of event ‘1a’ on cell 3 in IE "Event results".

NOTE: If the UE fails the test because of a failure to reselect to a right cell, then the operator may re-run the test.

Expected Sequence

Step

Direction

Message

Comment

UE

SS

1

UE is in PS-DCCH+DTCH_DCH (state 6-10) in cell 1.

2

Void

3

Void

4

Void

5

MEASUREMENT CONTROL

SS requests for measurement of cell 2´s CPICH RSCP value and reporting of CPICH RSCP values of active cells and monitored set cells.

6

MEASUREMENT REPORT

UE shall send periodic report at 16 seconds interval.

7

PHYSICAL CHANNEL RECONFIGURATION

SS moves the UE to CELL_FACH state.

8

PHYSICAL CHANNEL RECONFIGURATION COMPLETE

UE shall move to CELL_FACH state. SS starts T305 timer.

9

Master Information Block, Scheduling Block 1,

System Information Block type 11, 12

SS reconfigures itself according to the settings stated in column "T1" of table 8.4.1.5-1. SIB 11 is modified to indicate that SIB12 is now broadcast and to add cell 2 as a neighbour cell. SIB 12 indicates that cell 3 is included in the IE "intra-frequency cell info list". SS waits for 1 minute and verifies that no MEASUREMENT REPORT messages are detected on the uplink.

10

SYSTEM INFORMATION CHANGE INDICATION

SS waits until T305 has expired.

11

CELL UPDATE

UE shall transmit this message with measured results on RACH channels for cell 1 and cell 3 present in this message.

12

CELL UPDATE CONFIRM

No changes in physical resource allocation and RNTI identities.

13

PHYSICAL CHANNEL RECONFIGURATION

SS configures dedicated physical channels.

14

PHYSICAL CHANNEL RECONFIGURATION COMPLETE

UE shall transit to CELL_DCH state.

15

MEASUREMENT REPORT

Repeated at 500 milliseconds interval

Specific Message Content

System Information Block type 1 (FDD)

Use the default system information block with the same type specified in clause 6.1 of TS 34.108, with the following exceptions:

Information Element

Value/remark

– UE Timers and constants in connected mode

– T312

2

MEASUREMENT CONTROL (Step 5)

Information Element

Value/remark

Measurement Identity

5

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Periodical Reporting

Additional measurements list

Not Present

CHOICE measurement type

Intra-frequency measurement

– Intra-frequency cell info list

– CHOICE intra-frequency cell removal

Remove no intra-frequency cells

– New intra-frequency info list

– Intra-frequency cell id

2

– Cell info

– Cell individual offset

0 dB

– Reference time difference to cell

Not Present

– Read SFN Indicator

FALSE

– CHOICE mode

FDD

– Primary CPICH Info

– Primary Scrambling Code

Set to same code as used for cell 2

– Primary CPICH TX power

Not Present

– TX Diversity Indicator

FALSE

– Cells for measurement

Not Present

– Intra-frequency measurement quantity

– Filter Coefficient

Not Present (Default is 0)

– Measurement quantity

CPICH RSCP

– Intra-frequency reporting quantity

– Reporting quantities for active set cells

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CPICH Ec/No reporting indicator

FALSE

– CPICH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting quantities for monitored set cells

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CPICH Ec/No reporting indicator

FALSE

– CPICH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting quantities for detected cells

Not present

– Reporting cell status

– CHOICE reported cell

Report cells within active and/or monitored set on used frequency or within active and/or monitored set on non-used frequency

– Maximum number of reported cells

2

– Measurement validity

Not present

– CHOICE report criteria

Periodical reporting criteria

– Amount of reporting

Infinity

– Reporting interval

16 seconds

DPCH compressed mode status info

Not Present

MEASUREMENT REPORT (Step 6)

Information Element

Value/remark

Measurement identity

Check to see if set to 5

Measured Results

– CHOICE measurement

Check to see if set to "Intra-frequency measured results list"

– Intra-frequency measured results list

– Cell measured results

– Cell Identity

Check to see if it is absent

– Cell synchronisation information

Check to see if this IE is absent

– Primary CPICH Info

– Primary Scrambling Code

Check to see if it’s the same code for cell 1

– CPICH Ec/No

Check to see if this IE is absent

– CPICH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

– Cell measured results

This object may be absent in the first instance of the MEASUREMENT REPORT, but must be present in subsequent instances. If present the associated IEs should be checked as indicated.

– Cell Identity

Check to see if it is absent

– Cell synchronisation information

Check to see if this IE is absent

– Primary CPICH Info

– Primary Scrambling Code

Check to see if it’s the same code for cell 2

– CPICH Ec/No

Check to see if this IE is absent

– CPICH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

Measured Results on RACH

Check to see if this IE is absent

Additional measured result list

Check to see if this IE is absent

Event results

Check to see if this IE is absent

PHYSICAL CHANNEL RECONFIGURATION (Step 7)

Use the same message sub-type found in [9] TS 34.108 clause 9, which is entitled "(Packet to CELL_FACH from CELL_DCH in PS)"

MASTER INFORMATION BLOCK (Step 9)

Use the same message sub-type found in clause 6.1 of TS 34.108, with the following exception:

Information Element

Value/Remarks

MIB Value Tag

A value that is different from the previous MIB value tag

SB 1 Cell Value tag

Set to (Current SB1 value tag + 1)

SCHEDULING BLOCK 1 (Step 9)

Information Element

Value/remark

SIB 11 Cell Value tag

Set to (Current SIB 11 value tag + 1)

SIB 12 Cell Value tag

Set to (Current SIB 12 value tag + 1)

System Information Block type 11 (Step 9)

Information Element

Value/remark

SIB12 indicator

TRUE

FACH measurement occasion info

Not Present

Measurement control system information

– Intra-frequency measurement system information

– Intra-frequency measurement identity

Not present

– Intra-frequency cell info list

– CHOICE intra-frequency cell removal

Not Present

– New intra-frequency cells

– Intra-frequency cell id

1

– Cell info

– Cell individual offset

Not Present

– Reference time difference to cell

Not present

– Read SFN Indicator

FALSE

– CHOICE mode

FDD

– Primary CPICH Info

– Primary Scrambling Code

Refer to clause titled "Default settings for cell No.1 (FDD)" in clause 6.1.4 of TS 34.108

– Primary CPICH TX power

Not Present

– TX Diversity Indicator

FALSE

– Cell selection and Re-selection info

Not present

– Intra-frequency cell id

2

– Cell info

– Cell individual offset

Not Present

– Reference time difference to cell

Not present

– Read SFN Indicator

TRUE

– CHOICE mode

FDD

– Primary CPICH Info

– Primary Scrambling Code

Refer to clause titled "Default settings for cell No.2 (FDD)" in clause 6.1.4 of TS 34.108

– Primary CPICH TX power

Not Present

– TX Diversity Indicator

FALSE

– Cell selection and Re-selection info

– Qoffsets,n

0 dB

– Maximum allowed UL TX power

0 dBm

– HCS neighbouring cell information

Not Present

– CHOICE Mode

FDD

– Qqualmin

-20dB

– Qrxlevmin

-58 (-115dBm)

– Cells for measurement

Not Present

-Intra-frequency measurement quantity

Not Present

-Intra-frequency reporting quantity for RACH reporting

Not Present

-Maximum number of reported cells on RACH

Not Present

-Reporting information for state CELL_DCH

Not Present

– Inter-frequency measurement system information

Not Present

– Inter-RAT measurement system information

Not Present

– Traffic volume measurement system information

Not Present

System Information Block type 12 (Step 9)

Information Element

Value/remark

FACH measurement occasion info

Not Present

Measurement control system information

– Use of HCS

Not used

– Cell selection and reselection quality measure

CPICH RSCP

– Intra-frequency measurement system information

– Intra-frequency measurement identity

6

– Intra-frequency cell cells

– CHOICE intra-frequency cell removal

Not Present

– New intra-frequency cells

– Intra-frequency cell id

3

– Cell info

– Cell individual offset

Not Present

– Reference time difference to cell

Not Present

– Read SFN Indicator

TRUE

– CHOICE mode

FDD

– Primary CPICH Info

– Primary Scrambling Code

Refer to clause titled "Default settings for cell No.3 (FDD)" in clause 6.1.4 of TS 34.108

– Primary CPICH TX power

Not Present

– TX Diversity Indicator

FALSE

– Cell selection and Re-selection info

– Qoffsets,n

0dB

– Maximum allowed UL TX power

0dBm

– HCS neighbouring cell information

Not Present

– CHOICE Mode

FDD

– Qqualmin

-20dB

– Qrxlevmin

-58 (-115dBm)

– Intra-frequency measurement quantity

– Filter Coefficient

Not Present (Default is 0)

– Measurement quantity

CPICH RSCP

– Intra-frequency reporting quantity for RACH reporting

– SFN-SFN observed time difference reporting indicator

No report

– CHOICE mode

FDD

– Reporting quantity

CPICH RSCP

– Maximum number of reported cells on RACH

Current cell + best neighbour

– Reporting information for state CELL_DCH

– Intra-frequency reporting quantity

– Reporting quantities for active set cells

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CHOICE mode

FDD

– CPICH Ec/No reporting indicator

FALSE

– CPICH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting quantities for monitored set cells

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CHOICE mode

FDD

– CPICH Ec/No reporting indicator

FALSE

– CPICH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting quantities for detected cells

Not present

– Measurement Reporting Mode

– Measurement Report Transfer Mode

Acknowledged mode RLC

– Periodic Reporting/Event Trigger Reporting Mode

Event trigger

– CHOICE report criteria

Intra-frequency measurement reporting criteria

– Parameter required for each event

– Intra-frequency event identity

1a

– Triggering condition 1

Not Present

– Triggering condition 2

Monitored set cells

– Reporting range constant

29 (14.5dB)

– Cells forbidden to affect reporting

Not present

– W

0.0

– Hysteresis

2 (1.0 dB)

– Threshold used frequency

Not Present

– Reporting deactivation threshold

7

– Replacement activation threshold

Not Present

– Time to trigger

60 ms

– Amount of reporting

Infinity

– Reporting Interval

500 milliseconds

– Reporting cell status

– CHOICE reported cell

Report cells within active and/or monitored set on used frequency or within active and/or monitored set on non-used frequency

– Maximum number of reported cells

2

– Inter-frequency measurement system information

Not present

– Inter-RAT measurement system information

Not present

– Traffic volume measurement system information

Not present

SYSTEM INFORMATION CHANGE INDICATION (Step 10)

Information Element

Value/Remarks

BCCH modification info

– MIB Value tag

A value that is different from the previous MIB value tag

CELL UPDATE (Step 11)

Information Element

Value/remark

U-RNTI

Check to see if set to the same value assigned during the execution of procedure P3 or P5.

START list

Checked to see if this IE is present

AM_RLC error indication(RB2, RB3 or RB4)

FALSE

AM_RLC error indication(RB>4)

FALSE

Cell update cause

Check to see if it is set to "Periodical cell update"

Failure case

Check to see if it is absent

Measured results on RACH

– Measurement result for current cell

– CHOICE measurement quantity

Check to see if set to "CPICH RSCP"

– CPICH RSCP

Check to see if it is present

– Measurement results for monitored cells

– SFN-SFN observed time difference

Check to see if it is absent

– Primary CPICH info

– Primary scrambling code

Check to see if the same as cell 3’s code.

– CHOICE measurement quantity

Check to see if set to "CPICH RSCP"

– CPICH RSCP

Check to see if it is present

PHYSICAL CHANNEL RECONFIGURATION (Step 13)

Use the same message sub-type found in [9] TS 34.108 clause 9, which is entitled "(Packet to CELL_DCH from CELL_FACH in PS)".

MEASUREMENT REPORT (Step 15)

Information Element

Value/remark

Measurement identity

Check to see if set to 6

Measured Results

– CHOICE measurement

Check to see if set to "Intra-frequency measured results list"

– Intra-frequency measurement results list

– Cell measured results

– Cell Identity

Check to see if it is absent

– Cell synchronisation information

Check to see if this IE is absent

– Primary CPICH Info

– Primary Scrambling Code

Check to see if it’s the same code for cell 1

– CPICH Ec/No

Check to see if this IE is absent

– CPICH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

– Cell measured results

– Cell Identity

Check to see if it is absent

– Cell synchronisation information

Check to see if this IE is absent

– Primary CPICH Info

– Primary Scrambling Code

Check to see if it’s the same code for cell 3

– CPICH Ec/No

Check to see if this IE is absent

– CPICH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

Measured Results on RACH

Check to see if this IE is absent

Event results

Check to see if this set to ‘Intra-frequency measurement event results’

– Intra-frequency event identity

Check to see if set to ‘1a’

– Cell measurement event results

– CHOICE Mode

Check to see if set to ‘FDD’

– Primary CPICH info

– Primary Scrambling Code

Check to see if set to the same code for cell 3

8.4.1.5.5 Test Requirement

After step 5, the UE shall start to transmit MEASUREMENT REPORT messages at 16 seconds interval. The first message may contain the IE "Cell measured results" to report cell 2’s CPICH RSCP value, subsequent messages shall contain this IE.

After step 8, the UE shall not send any MEASUREMENT REPORT messages containing reporting quantities requested in MEASUREMENT CONTROL messages in step 5.

After step 10, the UE shall perform a cell update procedure and transmit a CELL UPDATE message. In this message, measured values CPICH RSCP for cell 1 and cell 3 shall be included in the IE "measured results on RACH".

After step 14, the UE shall apply the intra-frequency measurement reporting criteria" received in System Information Block type 12 messages of step 9. It shall send MEASUREMENT REPORT messages at 500 milliseconds interval. In these messages, triggering of event ‘1a’ shall be reported in IE "Event results" with IE "Primary CPICH info" containing the primary scrambling code for cell 3.

The message shall contain IE "measured result" to report CPICH RSCP values of cell 1and 3.

8.4.1.5a Measurement Control and Report: Intra-frequency measurement for transition from CELL_DCH to CELL_FACH state (TDD)

8.4.1.5a.1 Definition

8.4.1.5a.2 Conformance requirement

Upon transition from CELL_DCH to CELL_FACH/CELL_PCH/URA_PCH state, the UE shall:

1> stop intra-frequency type measurement reporting;

1> if the transition is due to a reconfiguration message which included the IE "Primary CPICH info" (for FDD) or "Primary CCPCH info" (for TDD), and the UE selects a cell other than that indicated by this IE; or

1> if the transition is due to a reconfiguration message which does not include the IE "Primary CPICH info" (for FDD) or "Primary CCPCH info" (for TDD); or

1> if the transition is not due to a reconfiguration message:

2> delete the measurements of type intra-frequency associated with the variable MEASUREMENT_IDENTITY.

1> begin monitoring cells listed in the IE "intra-frequency cell info list" received in System Information Block type 12 (or System Information Block type 11, according to subclause 8.1.1.6.11 in [8] TS 25.331).

Reference

3GPP TS 25.331, clause 8.4.1.6.1, 8.4.1.7.1

8.4.1.5a.3 Test Purpose

1. To confirm that the UE stops performing intra-frequency measurement reporting specified in a MEASUREMENT CONTROL message, when it moves from CELL_DCH state to CELL_FACH state.

2. To confirm that the UE reads the System Information Block type 11 or 12 messages when it enters CELL_FACH state from CELL_DCH state, and starts to monitor the cells listed in the IE "intra-frequency cell info list".

3 To confirm that the UE performs measurements on uplink RACH transmissions and appends the measured results in RACH messages, when it receives IE "intra-frequency reporting quantity for RACH reporting" and IE "Maximum number of reported cells on RACH" in the System Information Block type 11 or 12 messages.

4. To confirm that the UE applies the reporting criteria in IE "intra-frequency reporting criteria" in System Information Block Type 11 or 12 messages following a state transition from CELL_FACH to CELL_DCH, if no intra-frequency measurements applicable to CELL_DCH are stored.

8.4.1.5a.4 Method of test

Initial Condition

System Simulator: 3 cells – Cell 1 and cell 2 are active, while cell 3 is switched off.

UE: PS-DCCH+DTCH_DCH (state 6-10) in cell 1 as specified in clause 7.4 of TS 34.108.

Specific Message Contents

For MASTER IFORMATION BLOCK and system information block 11 of Cell 1 (gives IE’s which are different from defaults given in 34.108 subclause 6.1) to be transmitted before idle update preamble.

MASTER INFORMATION BLOCK

Use the same message sub-type found in clause 6.1 of TS 34.108, with the following exception:

Information Element

Value/Remarks

MIB Value Tag

A valid MIB value tag as defined in TS 25.331

System Information Block type 11

Use the same message sub-type found in clause 6.1 of TS 34.108, with the following exception:

Information Element

Value/remark

SIB12 indicator

FALSE

FACH measurement occasion info

Not Present

Measurement control system information

– Use of HCS

Not used

– Intra-frequency measurement system information

– Intra-frequency measurement identity

Not present

– Intra-frequency cell info list

– CHOICE intra-frequency cell removal

Not present

– New intra-frequency cells

– Intra-frequency cell id

1

– Cell info

– Cell individual offset

Not present

– Reference time difference to cell

Not present

– Read SFN Indicator

FALSE

– CHOICE mode

TDD

– Primary PCCPCH Info

Refer to clause titled "Default settings for cell No.1 (TDD)" in clause 6.1.4 of TS 34.108

– Cell selection and Re-selection info

Not present

– Cells for measurement

Not Present

-Intra-frequency measurement quantity

Not Present

-Intra-frequency reporting quantity for RACH reporting

Not Present

-Maximum number of reported cells on RACH

Not Present

-Reporting information for state CELL_DCH

Not Present

– Inter-frequency measurement system information

Not Present

– Inter-RAT measurement system information

Not Present

– Traffic volume measurement system information

Not Present

Test Procedure

Table 8.4.1.5a-1 illustrates the downlink power to be applied for the 3 cells at various time instants of the test execution. Columns marked "T0" denote the initial conditions, while column marked as "T1" will be applied during the test.

Table 8.4.1.5a-1

Parameter

Unit

Cell 1

Cell 2

Cell 3

T0

T1

T2

T0

T1

T2

T0

T1

T2

UTRA RF Channel Number

Mid Range Test Frequency

Mid Range Test Frequency

Mid Range Test Frequency

PCCPCH RSCP

dBm

-60

-60

-70

-75

-85

-85

OFF

-70

-60

The UE is initially in CELL_DCH state. The System Information Block type 11 message is modified compared to the default message contents, in order to prevent the reporting of "Cell synchronisation information". No measurement to be applied by the UE in CELL_DCH state is specified in any of the System Information Block type 11 or 12 messages.

SS sends a MEASUREMENT CONTROL message to UE. In this message, the SS requests the establishment of an intra-frequency measurement for the measurement of cell 2’s PCCPCH RSCP. At the same time, reporting of PCCPCH RSCP values of active set cells and monitored set cells are requested with the reporting criteria set to "periodic reporting" and "reporting interval" set to 16 seconds. The UE shall start transmitting MEASUREMENT REPORT messages at 16 seconds interval corresponding to the requested reporting event.

SS transmits PHYSICAL CHANNEL RECONFIGURATION message to move the UE to CELL_FACH. After receiving this message, the UE shall reconfigure itself and reply with a PHYSICAL CHANNEL RECONFIGURATION COMPLETE message on RACH. SS monitors the uplink channels to verify that no MEASUREMENT REPORT messages are received.

SS reconfigures itself according to the settings in columns marked "T1" in table 8.4.1.5a-1. SS transmits System Information Block type 12 messages in cell 1, which include cell 3 into the IE "intra-frequency cell info list" and modifies SIB11 to indicate that SIB12 is now being broadcast. IEs "Intra-frequency reporting quantity for RACH Reporting" and IE "Maximum number of Reported cells on RACH" are also specified in the System Information Type 12 messages. Event type 1g reporting criterion is specified for intra-frequency measurements. SS transmit SYSTEM INFORMATION CHANGE INDICATION message to UE. SS waits until T305 has expired. The UE shall respond with a CELL UPDATE message, which comprises IE "Measured results on RACH" to report the readings of PCCPCH RSCP for cell 1 and cell 3. SS replies with CELL UPDATE CONFIRM message on the downlink DCCH. This message does not change the physical resources nor allocate any new RNTI identities. SS transmits PHYSICAL CHANNEL RECONFIGURATION message again, and configures dedicated physical channel for both uplink and downlink directions. The UE shall send PHYSICAL CHANNEL RECONFIGURATION COMPLETE message and return to CELL_DCH state. SS listens to the uplink DCCH for MEASUREMENT REPORT messages.

SS reconfigures itself according to the settings in columns marked "T2" in table 8.4.1.5a-1. Event 1g is triggered since the best cell is changed to cell 3 from cell 1.

SS shall receive the MEASUREMENT REPORT messages.

SS verifies that it includes PCCPCH RSCP values of the cells 1, 2 and 3 in IE "Cell measured results" and the triggering of event ‘1g’ on cell 3 in IE "Event results".

Expected Sequence

Step

Direction

Message

Comment

UE

SS

1

UE is in PS-DCCH+DTCH_DCH (state 6-10) in cell 1.

2

MEASUREMENT CONTROL

SS requests for measurement of cell 2´s PCCPCH RSCP value and reporting of PCCPCH RSCP values of active cell and monitored set cell.

3

MEASUREMENT REPORT

UE shall send periodic report at 16 seconds interval.

4

PHYSICAL CHANNEL RECONFIGURATION

SS moves the UE to CELL_FACH state.

5

PHYSICAL CHANNEL RECONFIGURATION COMPLETE

UE reaches CELL_FACH state.

6

Master Information Block

System Information Block type 11, 12

SS reconfigures itself according to the settings stated in column "T1" of table 8.4.1.5a-1. SIB 11 is modified to indicate that SIB12 is now broadcast and includes cell 2 as a neighbour cell. SIB 12 indicates that cell 3 is included in the IE "intra-frequency cell info list". Event 1g is also configured for cell 3. SS waits for 1 minute and verifies that no MEASUREMENT REPORT messages are detected on the uplink.

7

SYSTEM INFORMATION CHANGE INDICATION

SS waits until T305 has expired.

8

CELL UPDATE

UE shall transmit this message with measured results on RACH channels for cell 1 and cell 3 present in this message.

9

CELL UPDATE CONFIRM

No changes in physical resource allocation and RNTI identities.

10

PHYSICAL CHANNEL RECONFIGURATION

SS configures dedicated physical channels.

11

PHYSICAL CHANNEL RECONFIGURATION COMPLETE

UE shall transit to CELL_DCH state.

11a

SS reconfigures itself according to the settings stated in column “T2” of table 8.4.1.5a-1.

12

MEASUREMENT REPORT

The UE shall report event 1G for change to best cell, cell3.

Specific Message Content

MEASUREMENT CONTROL (Step 2)

Information Element

Value/remark

Measurement Identity

5

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Periodical Reporting

Additional measurements list

Not Present

CHOICE measurement type

Intra-frequency measurement

– Intra-frequency cell info list

– CHOICE intra-frequency cell removal

Remove no intra-frequency cells

– New intra-frequency info list

– Intra-frequency cell id

2

– Cell info

– Cell individual offset

0 dB

– Reference time difference to cell

Not Present

– Read SFN Indicator

FALSE

– CHOICE mode

TDD

– Primary CCPCH Info

Set to same as used for cell 2

– Cells for measurement

Not Present

– Intra-frequency measurement quantity

– Filter Coefficient

Not Present (Default is 0)

– CHOICE mode

TDD

– Measurement quantity list

– Measurement quantity

PCCPCH RSCP

– Intra-frequency reporting quantity

– Reporting quantities for active set cells

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

CHOICE MODE

TDD

– Timeslot ISCP reporting indicator

FALSE

– Proposed TGSN Reporting required

FALSE

– PCCPCH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting quantities for monitored set cells

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

CHOICE MODE

TDD

– Timeslot ISCP reporting indicator

FALSE

– Proposed TGSN Reporting required

FALSE

– PCCPCH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting quantities for detected cells

Not present

– Reporting cell status

– CHOICE reported cell

Report cells within active and/or monitored set on used frequency or within active and/or monitored set on non-used frequency

– Maximum number of reported cells

2

– Measurement validity

Not present

– CHOICE report criteria

Periodical reporting criteria

– Amount of reporting

Infinity

– Reporting interval

16 seconds

MEASUREMENT REPORT (Step 3)

Information Element

Value/remark

Measurement identity

Check to see if set to 5

Measured Results

– CHOICE measurement

Check to see if set to "Intra-frequency measured results list"

– Intra-frequency measured results list

– Cell measured results

– Cell Identity

Check to see if it is absent

– Cell synchronisation information

Check to see if this IE is absent

– CHOICE mode

TDD

– Cell parameters Id

Check to see if it’s the same for cell 1

– Proposed TGSN

Check to see if this IE is absent

– Primary CCPCH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

– Timeslot list

Check to see if this IE is absent

– Cell measured results

– Cell Identity

Check to see if it is absent

– Cell synchronisation information

Check to see if this IE is absent

– CHOICE mode

TDD

– Cell parameters Id

Check to see if it’s the same for cell 2

– Proposed TGSN

Check to see if this IE is absent

– Primary CCPCH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

– Timeslot list

Check to see if this IE is absent

Measured Results on RACH

Check to see if this IE is absent

Additional measured result list

Check to see if this IE is absent

Event results

Check to see if this IE is absent

PHYSICAL CHANNEL RECONFIGURATION (Step 4)

Use the same message sub-type found in [9] TS 34.108 clause 9, which is entitled "(Packet to CELL_FACH from CELL_DCH in PS)"

MASTER INFORMATION BLOCK (Step 6)

Use the same message sub-type found in clause 6.1 of TS 34.108, with the following exception:

Information Element

Value/Remarks

MIB Value Tag

A valid MIB value tag as defined in TS 25.331 that is different from the previous value

System Information Block type 11 (Step 6)

Information Element

Value/remark

SIB12 indicator

TRUE

FACH measurement occasion info

Not Present

Measurement control system information

– Intra-frequency measurement system information

– Intra-frequency measurement identity

Not present

– Intra-frequency cell info list

– CHOICE intra-frequency cell removal

Not Present

– New intra-frequency cells

– Intra-frequency cell id

1

– Cell info

– Cell individual offset

Not Present

– Reference time difference to cell

Not present

– Read SFN Indicator

FALSE

– CHOICE mode

TDD

– Primary PCCPCH Info

Refer to clause titled "Default settings for cell No.1 (TDD)" in clause 6.1.4 of TS 34.108

– Cell selection and Re-selection info

Not present

– Intra-frequency cell id

2

– Cell info

– Cell individual offset

Not Present

– Reference time difference to cell

Not present

– Read SFN Indicator

FALSE

– CHOICE mode

TDD

– Primary PCCPCH Info

Refer to clause titled "Default settings for cell No.2 (TDD)" in clause 6.1.4 of TS 34.108

– Cell selection and Re-selection info

– Qoffsets,n

0 dB

– Maximum allowed UL TX power

0 dBm

– HCS neighbouring cell information

Not Present

– CHOICE Mode

TDD

– Qrxlevmin

-52 (-103 dBm)

– Cells for measurement

Not Present

-Intra-frequency measurement quantity

Not Present

-Intra-frequency reporting quantity for RACH reporting

Not Present

-Maximum number of reported cells on RACH

Not Present

-Reporting information for state CELL_DCH

Not Present

– Inter-frequency measurement system information

Not Present

– Inter-RAT measurement system information

Not Present

– Traffic volume measurement system information

Not Present

System Information Block type 12 (Step 6)

Information Element

Value/remark

FACH measurement occasion info

Not Present

Measurement control system information

– Use of HCS

Not used

– Intra-frequency measurement system information

– Intra-frequency measurement identity

6

– Intra-frequency cell cells

– CHOICE intra-frequency cell removal

Not Present

– New intra-frequency cells

– Intra-frequency cell id

3

– Cell info

– Cell individual offset

Not Present

– Reference time difference to cell

Not Present

– Read SFN Indicator

FALSE

– CHOICE mode

TDD

– Primary CCPCH Info

Refer to clause titled "Default settings for cell No.3 (TDD)" in clause 6.1.4 of TS 34.108

– Cell selection and Re-selection info

– Qoffsets,n

0dB

– Maximum allowed UL TX power

30dBm

– HCS neighbouring cell information

Not Present

– CHOICE Mode

TDD

– Qrxlevmin

-52 (-103dBm)

– Intra-frequency measurement quantity

– Filter Coefficient

Not Present (Default is 0)

– CHOICE mode

TDD

– Measurement list

– Measurement quantity

PCCPCH RSCP

– Intra-frequency reporting quantity for RACH reporting

– SFN-SFN observed time difference reporting indicator

No report

– CHOICE mode

TDD

– Reporting quantity

PCCPCH RSCP

– Maximum number of reported cells on RACH

Current cell + best neighbour

– Reporting information for state CELL_DCH

– Intra-frequency reporting quantity

– Reporting quantities for active set cells

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CHOICE mode

TDD

– Timeslot ISCP reporting indicator

FALSE

– Proposed TGSN Reporting required

FALSE

– PCCPCH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting quantities for monitored set cells

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CHOICE mode

TDD

– Proposed TGSN Reporting required

FALSE

– PCCPCH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting quantities for detected cells

Not present

– CHOICE report criteria

Intra-frequency measurement reporting criteria

– Parameter required for each event

– Intra-frequency event identity

1g

– Reporting range constant

20.0 dB

– W

0.0

– Hysteresis

2 (1.0 dB)

– Time to trigger

60 ms

– Amount of reporting

absent

– Reporting Interval

absent

– Reporting cell status

– CHOICE reported cell

Report cells within active and/or monitored set on used frequency or within active and/or monitored set on non-used frequency

– Maximum number of reported cells

3

– Inter-frequency measurement system information

Not present

– Inter-RAT measurement system information

Not present

– Traffic volume measurement system information

Not present

SYSTEM INFORMATION CHANGE INDICATION (Step 7)

Information Element

Value/Remarks

BCCH modification info

– MIB Value tag

A valid MIB value tag as defined in TS 25.331 that is different from the previous value

CELL UPDATE (Step 8)

Information Element

Value/remark

U-RNTI

Check to see if set to the same value assigned during the execution of procedure P3 or P5.

START list

Checked to see if this IE is present

AM_RLC error indication(RB2, RB3 or RB4)

FALSE

AM_RLC error indication(RB>4)

FALSE

Cell update cause

Check to see if it is set to "Periodical cell update"

Failure case

Check to see if it is absent

Measured results on RACH

– Measurement result for current cell

– SFN-SFN observed time difference

Not Checked

– CHOICE mode

TDD

– Cell parameters Id

Check to see if the same as cell 1.

– PCCPCH RSCP

Check to see if it is present

– Measurement results for monitored cells

– SFN-SFN observed time difference

Not Checked

– CHOICE mode

TDD

– Cell parameters Id

Check to see if the same as cell 3.

– PCCPCH RSCP

Check to see if it is present

PHYSICAL CHANNEL RECONFIGURATION (Step 10)

Use the same message sub-type found in [9] TS 34.108 clause 9, which is entitled "(Packet to CELL_DCH from CELL_FACH in PS)".

MEASUREMENT REPORT (Step 12)

Information Element

Value/remark

Measurement identity

Check to see if set to 6

Measured Results

– CHOICE measurement

Check to see if set to "Intra-frequency measured results list"

– Intra-frequency measurement results list

– Cell measured results

– Cell Identity

Check to see if it is absent

– Cell synchronisation information

Check to see if this IE is absent

– CHOICE mode

TDD

– Cell parameters Id

Check to see if it’s the same for cell 3

– Proposed TGSN

Check to see if this IE is absent

– Primary CCPCH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

– Timeslot list

Check to see if it is absent

– Cell measured results

– Cell Identity

Check to see if it is absent

– Cell synchronisation information

Check to see if this IE is absent

– CHOICE mode

TDD

– Cell parameters Id

Check to see if it’s the same for cell 1

– Proposed TGSN Reporting required

Check to see if this IE is absent

– Primary CCPCH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

– Timeslot list

Check to see if it is absent

– Cell measured results

– Cell Identity

Check to see if it is absent

– Cell synchronisation information

Check to see if this IE is absent

– Cell parameters Id

Check to see if it’s the same for cell 2

– Proposed TGSN Reporting required

Check to see if this IE is absent

– PCCPCH RSCP reporting indicator

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

Measured Results on RACH

Check to see if this IE is absent

Event results

Check to see if this set to ‘Intra-frequency measurement event results’

– Intra-frequency event identity

Check to see if set to ‘1g’

– Cell measurement event results

– CHOICE Mode

Check to see if set to ‘TDD’

– Cell parameters id

Check to see if it’s the same for cell 3

8.4.1.5a.5 Test Requirement

After step 2, the UE shall start to transmit MEASUREMENT REPORT messages at 16 seconds interval. The message shall contain IE "measured result" to report cell 2’s PCCPCH RSCP value.

After step 5, the UE shall not send any MEASUREMENT REPORT messages containing reporting quantities requested in MEASUREMENT CONTROL messages in step 2.

After step 7, the UE shall perform a cell update procedure and transmit a CELL UPDATE message. In this message, measured values PCCPCH RSCP for cell 1 and cell 3 shall be included in the IE "measured results on RACH".

After step 12, the UE shall apply the intra-frequency measurement reporting criteria" received in System Information Block type 12 messages of step 6. It shall send MEASUREMENT REPORT messages. In these messages, triggering of event ‘1g’ shall be reported in IE "Event results" with IE " Cell parameters Id " containing the same for cell 3.

The message shall contain IE "measured result" to report PCCPCH RSCP values of cell 1, 2 and 3.

8.4.1.6 Measurement Control and Report: Inter-frequency measurement for transition from CELL_DCH to CELL_FACH state (FDD)

8.4.1.6.1 Definition

8.4.1.6.2 Conformance requirement

Upon transition from CELL_DCH to CELL_FACH/ CELL_PCH/URA_PCH state, the UE shall:

1> stop the inter-frequency type measurement reporting assigned in a MEASUREMENT CONTROL message;

1> begin monitoring cells listed in the IE "inter-frequency cell info list" received in System Information Block type 12 (or System Information Block type 11);

1> in CELL_FACH state:

2> perform measurements on other frequencies according to the IE "FACH measurement occasion info".

Reference

3GPP TS 25.331, clause 8.4.1.6.2

8.4.1.6.3 Test Purpose

1. To confirm that UE ceases inter-frequency type measurement reporting assigned in MEASUREMENT CONTROL message when moving from CELL_DCH state to CELL_FACH.

2. To confirm that the UE begins to monitor the cells listed in "inter-frequency cell info" received in System Information Block type 11 or 12 messages, following a state transition from CELL_DCH state to CELL_FACH state.

8.4.1.6.4 Method of test

Initial Condition

System Simulator: 2 cells – Cell 1 and cell 2 are active.

UE: PS-DCCH+DTCH_DCH (state 6-10) in cell 1 as specified in clause 7.4 of TS 34.108.

Related ICS/IXIT statements

– Compressed mode required yes/no

Specific Message contents

System Information Block type 4

Use the same message type found in clause 6.1.0b of TS 34.108, with the following exceptions for Cell 1:

– Qqualmin

-16

For system information block 12 for Cell1 (gives IEs which are different from defaults given in 34.108 sec 6.1) to be transmitted before idle update preamble

System Information Block Type 12

Information Element

Value/remark

FACH measurement occasion info

– FACH Measurement occasion cycle length coefficient

3

– Inter-frequency FDD measurement indicator

FALSE

– Inter-frequency TDD measurement indicator

FALSE

– Inter-RAT measurement indicators

Not Present

Measurement control system information

– Intra-frequency measurement system information

Not Present

– Inter-frequency measurement system information

Not Present

– Inter-RAT measurement system information

Not Present

– Traffic volume measurement system information

Not Present

Test Procedure

Table 8.4.1.6-1 illustrates the downlink power to be applied for the 2 cells at various time instants of the test execution. Columns marked "T0" denote the initial conditions, while columns marked "T1 are to be applied subsequently. The exact instants on which these values shall be applied are described in the texts in this clause.

Table 8.4.1.6-1

Parameter

Unit

Cell 1

Cell 4

T0

T1

T0

T1

UTRA RF Channel Number

Mid Range Test Frequency

High Range Test Frequency

CPICH Ec

dBm/3.84 MHz

-60

-75

-75

-60

The UE is initially in CELL_DCH state. The System Information Block type 12 message is modified with respect to the default settings, so that no measurement tasks are required of the UE. If UE requires compressed mode, SS transmits PHYSICAL CHANNEL RECONFIGURATION message. In this message, IE "DPCH compressed mode info" is present, which indicates that the UE shall apply the given parameters for compressed mode operations. The UE shall return a PHYSICAL CHANNEL RECONFIGURATION COMPLETE message to acknowledge that compressed mode mechanism can be exercised.

SS sends a MEASUREMENT CONTROL message to the UE, including cell 4 into the IE "inter-frequency cell info". The IE "CHOICE reporting criteria" in this message is set to "periodic reporting criteria". SS waits for 8 seconds to allow the periodic timer to expire. The UE shall send a MEASUREMENT REPORT message containing IE "inter-frequency cell measurement results" to report cell 4’s CPICH RSCP value. SS transmits PHYSICAL CHANNEL RECONFIGURATION message and reconfigures common physical channels. The UE shall move to CELL_FACH state and then return a PHYSICAL CHANNEL RECONFIGURATION COMPLETE message to SS.

SS modifies the contents of Master Information Block (MIB) and System Information Block (SIB) type 12. In SIB 12, cell 4 is added to the cells listed in the "inter-frequency cell info" IE. SS transmit SYSTEM INFORMATION CHANGE INDICATION message to UE. SS waits for 8 seconds to detect any uplink MEASUREMENT REPORT messages. SS verifies that no MEASUREMENT REPORT message(s) are received as a result of inter-frequency measurements. SS then reconfigures the downlink transmission power settings of cell 1 and cell 4 according to the values stated in columns "T1" of table 8.4.1.6-1. SS waits for the UE to perform cell re-selection. The UE shall transmit a CELL UPDATE message on the uplink CCCH of cell 4, specifying the "cell update cause" IE as "cell re-selection". SS replies with CELL UPDATE CONFIRM message, which includes IE "New C-RNTI", on the downlink DCCH to complete the cell update procedure. The UE shall reply with a UTRAN MOBILITY INFORMATION CONFIRM message.

NOTE: If the UE fails the test because of a failure to reselect to a right cell, then the operator may re-run the test.

Expected Sequence

Step

Direction

Message

Comment

UE

SS

1

Void

2

If compressed mode is not required (refer ICS/IXIT), goto step 8.

3

Void

4

Void

5

Void

6

PHYSICAL CHANNEL RECONFIGURATION

SS instructs UE to begin compressed mode operation.

7

PHYSICAL CHANNEL RECONFIGURATION COMPLETE

UE shall remain in CELL_DCH state.

8

MEASUREMENT CONTROL

SS indicates that the CPICH RSCP of cell 4 shall be monitored and reported. SS waits for 8 seconds for the reception of MEASUREMENT REPORT message.

9

MEASUREMENT REPORT

UE shall transmit this message to report cell 4’s CPICH RSCP value.

10

PHYSICAL CHANNEL RECONFIGURATION

SS configures common physical channels.

11

PHYSICAL CHANNEL RECONFIGURATION COMPLETE

UE shall moves to CELL_FACH state.

12

Master Information Block,

Scheduling Block 1,

System Information Block type 12

SS modifies MIB and SIB 12. Cell 4 is included in the IE "inter-frequency cell info"

13

SYSTEM INFORMATION CHANGE INDICATION

SS waits for 8 seconds to verify that no MEASUREMENT REPORT messages are detected on the uplink DCCH.

14

SS changes the power settings for cell 1 and cell 4 according to columns marked "T1" of table 8.4.1.6-1, and then waits for the UE to re-select to a new cell.

15

CELL UPDATE

UE shall perform cell re-selection and transmit this message on the new cell.

16

CELL UPDATE CONFIRM

See message content.

17

UTRAN MOBILITY INFORMATION CONFIRM

Specific Message Content

PHYSICAL CHANNEL RECONFIGURATION (Step 6)

Use the same message sub-type found in Annex A, which is entitled "(Packet to CELL_DCH from CELL_DCH in PS)", with the following exceptions in the IE(s) concerned:

Information Element

Value/remark

Version

Downlink information common for all radio links

– Downlink DPCH info common for all RL

Not Present

– CHOICE Mode

FDD

– DPCH compressed mode info

– TGPSI

1

– TGPS Status Flag

Activate

– TGCFN

(Current CFN+(256 – TTI/10msec)) mod 256

– Transmission gap pattern sequence configuration parameters

– TGMP

FDD Measurement

– TGPRC

Infinity

– TGSN

4

– TGL1

7

– TGL2

Not Present

– TGD

undefined

– TGPL1

3

– TGPL2

Not Present

R99 and REL-4 only

– RPP

Mode 0

– ITP

Mode 0

– CHOICE UL/DL Mode

UL and DL or DL only depending on UE capability

– Downlink compressed mode method

SF/2

– Uplink compressed mode method

SF/2 or Not present depending on UE capability

– Downlink frame type

B

– DeltaSIR1

20 (2.0)

– DeltaSIRAfter1

10 (1.0)

– DeltaSIR2

Not Present

– DeltaSIRAfter2

Not Present

– N identify abort

Not Present

– T Reconfirm abort

Not Present

– TX Diversity Mode

None

– SSDT information

Not Present

R99 and Rel-4 only

– Default DPCH Offset Value

Not Present

Downlink information per radio link list

-Downlink information for each radio link

– Choice mode

FDD

– Primary CPICH info

– Primary scrambling code

Ref. to the Default setting in clause 6.1 (FDD)

– PDSCH with SHO DCH info

Not Present

R99 and Rel-4 only

-PDSCH code mapping

Not Present

R99 and Rel-4 only

– Downlink DPCH info for each RL

– CHOICE mode

FDD

– Primary CPICH usage for channel estimation

Primary CPICH may be used

– DPCH frame offset

Set to value : Default DPCH Offset Value (as currently stored in SS) mod 38 400

– Secondary CPICH info

Not Present

– DL channelisation code

– Secondary scrambling code

1

– Spreading factor

Reference to clause 6.10 Parameter Set

– Code number

0

– Scrambling code change

No code change

– TPC combination index

0

– SSDT Cell Identity

Not Present

R99 and Rel-4 only

– Closed loop timing adjustment mode

Not Present

MEASUREMENT CONTROL (Step 8)

Information Element

Value/remark

Measurement Identity

15

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Periodical Reporting

Additional measurements list

Not Present

CHOICE measurement type

Inter-frequency measurement

– Inter-frequency cell info list

– CHOICE inter-frequency cell removal

No inter-frequency cells removed

– New inter-frequency info list

– Inter-frequency cell id

4

– Frequency info

– UARFCN uplink (Nu)

Not present

Absence of this IE is equivalent to applying the default duplex distance defined for the operating frequency according to 3GPP TS 25.101 [21]

– UARFCN downlink (Nd)

UARFCN of the downlink frequency for cell 4

– Cell info

– Cell individual offset

0 dB

– Reference time difference to cell

Not Present

– Read SFN Indicator

FALSE

– CHOICE Mode

FDD

– Primary CPICH Info

– Primary Scrambling Code

Set to same code as used for cell 4

– Primary CPICH TX power

Not Present

– TX Diversity Indicator

FALSE

– Cells for measurement

– Inter-frequency cell id

4

– Inter-frequency measurement quantity

– CHOICE reporting criteria

Inter-frequency reporting criteria

– Filter Coefficient

0

– Measurement quantity for frequency quality estimate

CPICH RSCP

– Inter-frequency reporting quantity

– UTRA Carrier RSSI

FALSE

– Frequency quality estimate

FALSE

– Non frequency related cell reporting quantities

– Cell synchronisation information reporting indicator

FALSE

– Cell Identity reporting indicator

FALSE

– CPICH Ec/No reporting indicator

FALSE

– CPICH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting cell status

– CHOICE reported cell

Report cells within active and/or monitored set on used frequency or within active and/or monitored set on non-used frequency

– Maximum number of reported cells

2

– Measurement validity

– UE state

CELL_DCH

– Inter-frequency set update

Not Present

– CHOICE report criteria

Periodic reporting criteria

– Amount of reporting

Infinity

– Reporting interval

8 seconds

DPCH compressed mode status info

Not Present

MEASUREMENT REPORT (Step 9)

Information Element

Value/remark

Measurement identity

Check to see if set to 15

Measured Results

– CHOICE measurement

Check to see if set to "Inter-frequency measured results list"

– Inter-frequency measurement results

– Frequency info

– UARFCN uplink

The presence of this IE is not checked

– UARFCN downlink

Check that the value of this IE is set to UARFCN for the downlink corresponding to f4

– UTRA carrier RSSI

Check to see if it is absent

– Inter-frequency cell measurement results

– Cell measured results

– Cell Identity

Check to see if it is absent

– Cell synchronisation information

Check to see if it is absent

– Primary CPICH Info

– Primary Scrambling Code

Check to see if set to the same code for cell 4

– CPICH Ec/No

Check to see if it is absent

– CPICH RSCP

Check to see if it is present

– Pathloss

Check to see if it is absent

Measured Results on RACH

Check to see if it is absent

Event Results

Check to see if it is absent

PHYSICAL CHANNEL RECONFIGURATION (Step 10)

If UE do not require compressed mode, use the same message sub-type found in TS 34.108 clause 9, which is entitled "(Packet to CELL_FACH from CELL_DCH in PS)".

If UE requires compressed mode, use the same message sub-type found in TS34.108 clause 9, which is entitled "(Packet to CELL_FACH from CELL_DCH in PS)", with the following exceptions in the IE(s) concerned:

Information Element

Value/Remarks

Version

Downlink information common for all radio links

– Downlink DPCH info common for all RL

Not Present

– CHOICE mode

FDD

– DPCH compressed mode info

– TGPSI

1

– TGPS Status Flag

Deactivate

– TGCFN

Not Present

– Transmission gap pattern sequence

configuration parameters

Not Present

– TX Diversity Mode

None

– SSDT information

Not Present

R99 and Rel-4 only

– Default DPCH Offset Value

Not Present

Master Information Block (Step 12)

Information Element

Value/Remarks

MIB value tag

A valid MIB value tag as defined in TS 25.331 that is different from the previous value

SB 1 Cell Value tag

Set to (Current SB1 value tag + 1)

Scheduling Block 1 (Step 12)

Information Element

Value/remark

SIB 12 Cell Value tag

Set to (Current SIB 12 value tag + 1)

System Information Block type 12 (Step 12)

Information Element

Value/remark

FACH measurement occasion info

– FACH Measurement occasion cycle length coefficient

3

– Inter-frequency FDD measurement indicator

TRUE

– Inter-frequency TDD measurement indicator

FALSE

– Inter-RAT measurement indicators

Not Present

Measurement control system information

– Use of HCS

Not used

– Cell selection and reselection quality measure

CPICH RSCP

– Intra-frequency measurement system information

Not Present

– Inter-frequency measurement system information

– Inter-frequency cell info list

– CHOICE Inter-frequency cell removal

Not Present

– New inter-frequency cells

– Inter-frequency cell id

4

– Frequency info

– CHOICE mode

FDD

– UARFCN uplink (Nu)

Not present

Absence of this IE is equivalent to applying the default duplex distance defined for the operating frequency according to 3GPP TS 25.101 [21]

– UARFCN downlink (Nd)

Reference to table 6.1.2 of TS 34.108 for Cell 4

– Cell info

– Cell individual offset

Not Present

– Reference time difference to cell

Not Present

– Read SFN indicator

FALSE

– CHOICE Mode

FDD

– Primary CPICH info

– Primary scrambling code

Refer to clause titled "Default settings for cell No.4 (FDD)" in clause 6.1.4 of TS 34.108

– Primary CPICH Tx power

Not Present

– TX diversity indicator

FALSE

– Cell selection and re-selection info

Not Present

– Inter-RAT measurement system information

Not Present

– Traffic volume measurement system information

Not Present

SYSTEM INFORMATION CHANGE INDICATION (Step 13)

Information Element

Value/Remarks

BCCH modification info

– MIB Value tag

A valid MIB value tag as defined in TS 25.331 that is different from the previous value

CELL UPDATE (Step 15)

Information Element

Value/remark

U-RNTI

Check to see if same to value assigned in P3 or P5 as described in TS34.108 clause 7.4.2

Cell update cause

Check to see if it is set to "Cell Reselection"

Protocol error info

Check to see if it is absent or set to FALSE

Measured results on RACH

Check to see if it is absent

Protocol error information

Check to see if it is absent

CELL UPDATE CONFIRM (Step 16)

Use the same message sub-type found in Annex A, with the following exceptions.

Information Element

Value/Remarks

New C-RNTI

‘1010 1010 1010 1010’

UTRAN MOBILITY INFORMATION CONFIRM (Step 17)

Only the message type is checked.

8.4.1.6.5 Test Requirement

If UE requires compressed mode, after step 6, the UE shall transmit PHYSICAL CHANNEL RECONFIGURATION COMPLETE message on the uplink DCCH using AM RLC.

After step 8 the UE shall transmit MEASUREMENT REPORT message to report cell 4’s RSCP value in the IE "inter-frequency cell measured results".

After step 10, the UE shall transmit PHYSICAL CHANNEL RECONFIGURATION COMPLETE message on the uplink DCCH using AM RLC.

After step 11 the UE shall stop sending MEASUREMENT REPORT messages, which contain inter-frequency measured results for cell 4’s CPICH RSCP value.

After step 14 the UE shall transmit CELL UPDATE message on the uplink CCCH of cell 4, and the "cell update cause" IE shall be set to "cell reselection".

After step 16, the UE shall transmit UTRAN MOBILITY INFORMATION CONFIRM message on the uplink DCCH AM RLC.

8.4.1.6a Measurement Control and Report: Inter-frequency measurement for transition from CELL_DCH to CELL_FACH state (TDD)

8.4.1.6a.1 Definition

8.4.1.6a.2 Conformance requirement

Upon transition from CELL_DCH to CELL_FACH/ CELL_PCH/URA_PCH state, the UE shall:

1> stop the inter-frequency type measurement reporting assigned in a MEASUREMENT CONTROL message;

1> begin monitoring cells listed in the IE "inter-frequency cell info list" received in System Information Block type 12 (or System Information Block type 11);

1> in CELL_FACH state:

2> perform measurements on other frequencies according to the IE "FACH measurement occasion info".

Reference

3GPP TS 25.331, clause 8.4.1.6.2

8.4.1.6a.3 Test Purpose

1. To confirm that UE ceases inter-frequency type measurement reporting assigned in MEASUREMENT CONTROL message when moving from CELL_DCH state to CELL_FACH.

2. To confirm that the UE begins to monitor the cells listed in "inter-frequency cell info" received in System Information Block type 11 or 12 messages, following a state transition from CELL_DCH state to CELL_FACH state.

8.4.1.6a.4 Method of test

Initial Condition

System Simulator: 2 cells – Cell 1 and cell 2 are active.

UE: PS-DCCH+DTCH_DCH (state 6-10) in cell 1 as specified in clause 7.4 of TS 34.108.

Test Procedure

Table 8.4.1.6a-1 illustrates the downlink power to be applied for the 2 cells at various time instants of the test execution. Columns marked "T0" denote the initial conditions, while columns marked "T1 are to be applied subsequently. The exact instants on which these values shall be applied are described in the texts in this clause.

Table 8.4.1.6a-1

Parameter

Unit

Cell 1

Cell 4

T0

T1

T0

T1

UTRA RF Channel Number

Mid Range Test Frequency

High Range Test Frequency

PCCPCH RSCP

dBm

-60

-75

-75

-60

The UE is initially in CELL_DCH state. The System Information Block type 12 message is modified with respect to the default settings, so that no measurement tasks are required of the UE.

SS sends a MEASUREMENT CONTROL message to the UE, including cell 4 into the IE "inter-frequency cell info". The IE "CHOICE reporting criteria" in this message is set to "periodic reporting criteria". SS waits for 8 seconds to allow the periodic timer to expire. The UE shall send a MEASUREMENT REPORT message containing IE "inter-frequency cell measurement results" to report cell 4’s PCCPCH RSCP value. SS transmits PHYSICAL CHANNEL RECONFIGURATION message and reconfigures common physical channels. The UE shall move to CELL_FACH state and then return a PHYSICAL CHANNEL RECONFIGURATION COMPLETE message to SS.

SS modifies the contents of Master Information Block (MIB) and System Information Block (SIB) type 12. In SIB 12, cell 4 is added to the cells listed in the "inter-frequency cell info" IE. SS transmit SYSTEM INFORMATION CHANGE INDICATION message to UE. SS waits for 8 seconds to detect any uplink MEASUREMENT REPORT messages. SS verifies that no MEASUREMENT REPORT message(s) are received as a result of inter-frequency measurements. SS then reconfigures the downlink transmission power settings of cell 1 and cell 4 according to the values stated in columns "T1" of table 8.4.1.6a-1. SS waits for the UE to perform cell re-selection. The UE shall transmit a CELL UPDATE message on the uplink CCCH of cell 4, specifying the "cell update cause" IE as "cell re-selection". SS replies with CELL UPDATE CONFIRM message, which includes IE "New C-RNTI", on the downlink DCCH to complete the cell update procedure. The UE shall reply with a UTRAN MOBILITY INFORMATION CONFIRM message.

NOTE: If the UE fails the test because of a failure to reselect to a right cell, then the operator may re-run the test.

Expected Sequence

Step

Direction

Message

Comment

UE

SS

1

System Information Block type 12

PS-DCCH+DTCH_DCH (state 6-10) in cell 1. System Information Block type 12 is modified with respect to the default settings. All measurement and reporting activities are disabled in this message.

2

MEASUREMENT CONTROL

SS indicates that the PCCPCH RSCP of cell 4 shall be monitored and reported. SS waits for 8 seconds for the reception of MEASUREMENT REPORT message.

3

MEASUREMENT REPORT

UE shall transmit this message to report cell 4’s PCCPCH RSCP value.

4

PHYSICAL CHANNEL RECONFIGURATION

SS configures common physical channels.

5

PHYSICAL CHANNEL RECONFIGURATION COMPLETE

UE shall moves to CELL_FACH state.

6

Master Information Block,

System Information Block type 12

SS modifies MIB and SIB 12. Cell 4 is included in the IE "inter-frequency cell info"

7

SYSTEM INFORMATION CHANGE INDICATION

SS waits for 8 seconds to verify that no MEASUREMENT REPORT messages are detected on the uplink DCCH.

8

SS changes the power settings for cell 1 and cell 4 according to columns marked "T1" of table 8.4.1.6a-1, and then waits for the UE to re-select to a new cell.

9

CELL UPDATE

UE shall perform cell re-selection and transmit this message on the new cell.

10

CELL UPDATE CONFIRM

See message content.

11

UTRAN MOBILITY INFORMATION CONFIRM

Specific Message Content

System Information Block Type 12 (Step 1)

Information Element

Value/remark

FACH measurement occasion info

– FACH Measurement occasion cycle length coefficient

2

– Inter-frequency FDD measurement indicator

FALSE

– Inter-frequency TDD measurement indicator

FALSE

– Inter-RAT measurement indicators

Not Present

Measurement control system information

– Intra-frequency measurement system information

Not Present

– Inter-frequency measurement system information

Not Present

– Inter-RAT measurement system information

Not Present

– Traffic volume measurement system information

Not Present

MEASUREMENT CONTROL (Step 2)

Information Element

Value/remark

Measurement Identity

15

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Periodical Reporting

Additional measurements list

Not Present

CHOICE measurement type

Inter-frequency measurement

– Inter-frequency cell info list

– CHOICE inter-frequency cell removal

No inter-frequency cells removed

– New inter-frequency info list

– Inter-frequency cell id

4

– Frequency info

– UARFCN (Nt)

UARFCN of the frequency for cell 4

– Cell info

– Cell individual offset

0 dB

– Reference time difference to cell

Not Present

– Read SFN Indicator

FALSE

– CHOICE Mode

TDD

– Primary CCPCH Info

Set to same as used for cell 4

– Primary CCPCH TX power

Not Present

– Timeslot list

Not Present

– Cells for measurement

– Inter-frequency cell id

4

– Inter-frequency measurement quantity

– CHOICE reporting criteria

Inter-frequency reporting criteria

– Filter Coefficient

0

– Measurement quantity for frequency quality estimate

PCCPCH RSCP

– Inter-frequency reporting quantity

– UTRA Carrier RSSI

FALSE

– Frequency quality estimate

FALSE

– Non frequency related cell reporting quantities

– Cell synchronisation information reporting indicator

FALSE

– Cell Identity reporting indicator

FALSE

– Timeslot ISCP reporting indicator

FALSE

– Proposed TGSN Reporting required

FALSE

– Primary CCPCH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting cell status

– CHOICE reported cell

Report cells within active and/or monitored set on used frequency or within active and/or monitored set on non-used frequency

– Maximum number of reported cells

2

– Measurement validity

– UE state

CELL_DCH

– Inter-frequency set update

Not Present

– CHOICE report criteria

Periodic reporting criteria

– Amount of reporting

Infinity

– Reporting interval

8 seconds

DPCH compressed mode status info

Not Present

MEASUREMENT REPORT (Step 3)

Information Element

Value/remark

Measurement identity

Check to see if set to 15

Measured Results

– CHOICE measurement

Check to see if set to "Inter-frequency measured results list"

– Inter-frequency measurement results

– Frequency info

– CHOICE mode

TDD

– UARFCN(Nt)

Check to see if set to the UARFCN of the frequency for cell 4

– UTRA carrier RSSI

Check to see if it is absent

– Inter-frequency cell measurement results

– Cell measured results

– Cell Identity

Check to see if it is absent

– Cell synchronisation information

Check to see if it is absent

– CHOICE mode

TDD

– cell parameters identity

Check to see if set to the same for cell 4

– proposed TGSN

Check to see if it is absent

– PCCPCH RSCP

Check to see if it is present

– Pathloss

Check to see if it is absent

– timeslot list

Check to see if it is absent

Measured Results on RACH

Check to see if it is absent

Event Results

Check to see if it is absent

PHYSICAL CHANNEL RECONFIGURATION (Step 4)

If UE do not require compressed mode, use the same message sub-type found in TS 34.108 clause 9, which is entitled "(Packet to CELL_FACH from CELL_DCH in PS)".

Master Information Block (Step 12)

Information Element

Value/Remarks

MIB value tag

A valid MIB value tag as defined in TS 25.331 that is different from the previous value

System Information Block type 12 (Step 6)

Information Element

Value/remark

FACH measurement occasion info

– FACH Measurement occasion cycle length coefficient

2

– Inter-frequency FDD measurement indicator

FALSE

– Inter-frequency TDD measurement indicator

TRUE

– Inter-RAT measurement indicators

Not Present

Measurement control system information

– Use of HCS

Not used

– Intra-frequency measurement system information

Not Present

– Inter-frequency measurement system information

– Inter-frequency cell info list

– CHOICE Inter-frequency cell removal

Not Present

– New inter-frequency cells

– Inter-frequency cell id

4

– Frequency info

– CHOICE mode

TDD

– UARFCN (Nt)

Reference to table 6.1.4 of TS 34.108 for Cell 4

– Cell info

– Cell individual offset

Not Present

– Reference time difference to cell

Not Present

– Read SFN indicator

FALSE

– CHOICE Mode

TDD

– Primary CCPCH info

Refer to clause titled "Default settings for cell No.4 (TDD)" in clause 6.1.4 of TS 34.108

– Cell selection and re-selection info

Not Present

– Inter-RAT measurement system information

Not Present

– Traffic volume measurement system information

Not Present

SYSTEM INFORMATION CHANGE INDICATION (Step 7)

Information Element

Value/Remarks

BCCH modification info

– MIB Value tag

A valid MIB value tag as defined in TS 25.331 that is different from the previous value

CELL UPDATE (Step 9)

Information Element

Value/remark

U-RNTI

Check to see if same to value assigned in P3 or P5

Cell update cause

Check to see if it is set to "Cell Reselection"

Measured results on RACH

Check to see if it is absent

CELL UPDATE CONFIRM (Step 10)

Use the same message sub-type found in TS 34.108 clause 9, with the following exceptions.

Information Element

Value/Remarks

New C-RNTI

‘1010 1010 1010 1010’

UTRAN MOBILITY INFORMATION CONFIRM (Step 11)

Only the message type is checked.

8.4.1.6a.5 Test Requirement

After step 2 the UE shall transmit MEASUREMENT REPORT message to report cell 4’s RSCP value in the IE "inter-frequency cell measured results".

After step 4, the UE shall transmit PHYSICAL CHANNEL RECONFIGURATION COMPLETE message on the uplink DCCH using AM RLC.

After step 5 the UE shall stop sending MEASUREMENT REPORT messages, which contain inter-frequency measured results for cell 4’s PCCPCH RSCP value.

After step 8 the UE shall transmit CELL UPDATE message on the uplink CCCH of cell 4, and the "cell update cause" IE shall be set to "cell reselection".

After step 10, the UE shall transmit UTRAN MOBILITY INFORMATION CONFIRM message on the uplink DCCH AM RLC.

8.4.1.7 Measurement Control and Report: Intra-frequency measurement for transition from CELL_FACH to CELL_DCH state (FDD)

8.4.1.7.1 Definition

8.4.1.7.2 Conformance requirement

Upon transition from CELL_FACH to CELL_DCH state:

1> if intra-frequency measurements applicable to CELL_DCH state are stored in the variable MEASUREMENT_IDENTITY:

2> if the cell in which the UE transited from CELL_FACH state is included in the active set for the CELL_DCH state, the UE shall:

3> resume the measurement reporting.

2> otherwise:

3> the UE should not resume the measurement reporting. If the UE does not resume the measurement reporting, the measurement shall be restarted when a MEASUREMENT CONTROL message is received with the corresponding measurement identity.

Upon cell reselection while in CELL_FACH/CELL_PCH/URA_PCH state and the cell reselection has occurred after the measurement control information was stored, the UE shall:

1> delete all measurements of type intra-frequency, inter-frequency, and inter-RAT associated with the variable MEASUREMENT_IDENTITY;

1> delete the traffic volume measurements that have not been set up or modified through a MEASUREMENT CONTROL message.

Upon reception of a MEASUREMENT CONTROL message the UE shall perform actions specified in subclause 8.6 unless otherwise specified below.

The UE shall:

1> read the IE "Measurement command";

1> if the IE "Measurement command" has the value "setup":

2> store this measurement in the variable MEASUREMENT_IDENTITY according to the IE "measurement identity", first releasing any previously stored measurement with that identity if that exists;

2> if the measurement type is quality, UE internal, intra-frequency, inter-frequency or inter-RAT:

3> if the UE is in CELL_FACH state:

4> the UE behaviour is not specified.

2> for measurement types "inter-RAT measurement" or "inter-frequency measurement" that require measurements on a frequency other than the actually used frequency:

2> for measurement type "inter-frequency measurement" that requires measurements only on the same frequency as the actually used frequency:

2> for measurement type "UE positioning measurement":

2> for any other measurement type:

3> if the measurement is valid in the current RRC state of the UE:

4> begin measurements according to the stored control information for this measurement identity.

1> if the IE "Measurement command" has the value "modify":

2> for all IEs present in the MEASUREMENT CONTROL message:

3> if a measurement was stored in the variable MEASUREMENT_IDENTITY associated to the identity by the IE "measurement identity":

4> if the measurement type is quality, UE internal, intra-frequency, inter-frequency or inter-RAT:

5> if the UE is in CELL_FACH state:

6> the UE behaviour is not specified.

4> if measurement type is set to "intra-frequency measurement", for any of the optional IEs "Intra-frequency measurement objects list", "Intra-frequency measurement quantity", "Intra-frequency reporting quantity", "Measurement Validity", "report criteria" and "parameters required for each event" (given "report criteria" is set to "intra-frequency measurement reporting criteria") that are present in the MEASUREMENT CONTROL message:

5> replace the corresponding information (the IEs listed above and all their children) stored in variable MEASUREMENT_IDENTITY associated to the identity indicated by the IE "measurement identity" with the one received in the MEASUREMENT CONTROL message;

5> leave all other stored information elements unchanged in the variable MEASUREMENT_IDENTITY.

1> if the IE "measurement command" has the value "release":

2> terminate the measurement associated with the identity given in the IE "measurement identity";

2> clear all stored measurement control information related associated to this measurement identity in variable MEASUREMENT_IDENTITY.

"If the IE "Reporting Cell Status" is received, the UE shall set the IE "Measured Results" in MEASUREMENT REPORT as follows. The UE shall:

1>      for intra-frequency measurement and inter-frequency measurement:
        2>      include the IE "Cell Measured Results" for cells (excluding cells of another RAT) that satisfy the condition (such as "Report cells within active set") specified in the IE "Reporting Cell Status", in descending order by the measurement quantity"

If the IE "Cells for measurement" has been included in a MEASUREMENT CONTROL message, only monitored set cells explicitly indicated for a given intra-frequency (resp. inter-frequency, interRAT) measurement by the IE "Cells for measurement" shall be considered for measurement. If the IE "Cells for measurement" has not been included in a MEASUREMENT CONTROL message, all of the intra-frequency (resp. inter-frequency, inter RAT) cells stored in the variable CELL_INFO_LIST shall be considered for measurement. The IE "Cells for measurement" is not applicable to active set cells or virtual active set cells e.g. when the triggering condition refers to active set cells, the UE shall consider all active set cells in the CELL_INFO_LIST for measurement irrespective if these cells are explicitly indicated by the IE "Cells for measurement".

Reference

3GPP TS 25.331, clause 8.4.1.3, 8.4.1.6a, 8.4.1.7.1, 8.4.0 and 8.6.7.9

8.4.1.7.3 Test Purpose

– To confirm that UE retrieves stored measurement control information for intra-frequency measurement type with "measurement validity" assigned to "CELL_DCH", after it enters CELL_DCH state from CELL_FACH state.

– To confirm that the UE continues to monitor the neighbouring cells listed "intra-frequency cell info" IE in the System Information Block type 11 or 12 messages, if no intra-frequency measurements applicable to CELL_DCH are stored.

– To confirm that the UE transmits MEASUREMENT REPORT messages if reporting criteria stated in IE "intra-frequency measurement reporting criteria" in System Information Block type 11 or 12 messages are fulfilled.

– To confirm that a MEASUREMENT CONTROL message received in CELL_DCH state overrides the measurement and associated reporting contexts maintained in the UE by virtue of System Information Block type 11 or 12.

– To confirm that the UE delete all measurements of type intra-frequency upon cell reselection while in CELL_FACH.

8.4.1.7.4 Method of test

Initial Condition

System Simulator: 3 cells – Cell 1, cell 2 and cell 3 are active.

SYSTEM INFORMATION BLOCK TYPE 1 (see specific message contents).

UE: PS-DCCH+DTCH_FACH (state 6-11).

Test Procedure

Table 8.4.1.7-1 illustrates the downlink power to be applied for the 3 cells at various time instants of the test execution. Column marked "T0" denotes the initial conditions, while columns marked "T1" are to be applied subsequently. The exact instants on which these values shall be applied are described in the text in this clause.

Table 8.4.1.7-1

Parameter

Unit

Cell 1

Cell 2

Cell 3

T0

T1

T2

T0

T1

T2

T0

T1

T2

UTRA RF Channel Number

Mid Range Test Frequency

Mid Range Test Frequency

Mid Range Test Frequency

CPICH Ec

dBm/3.84 MHz

-60

-70

-70

-65

-60

-60

-70

-70

-60

The UE is brought to CELL_FACH state in cell 1. (step 1) SS sends SYSTEM INFORMATION CHANGE INDICATION message to UE to inform UE of the modification in the system information.

SS sends a RADIO BEARER RECONFIGURATION message to UE (step2), and configures dedicated physical channels on both uplink and downlink directions. The UE shall move to CELL_DCH state and then return RADIO BEARER RECONFIGURATION COMPLETE message (step3). The UE shall send a MEASUREMENT REPORT message containing IE "Measured results" to report cell 2’s CPICH RSCP value and IE "event results" to report triggering of event type "1e" (step 4). After receiving the MEASUREMENT REPORT message, SS transmits a MEASUREMENT CONTROL message with only cell 3 included in the IE "intra-frequency cell info" (step 5). After receiving such a message, the UE shall transmit another set of MEASUREMENT REPORT message for measurement identity = 11. SS verifies that measurement readings for cell 3 ‘s CPICH RSCP are reported in IE "cell measured results" in this message (step 6). Cell 3 shall also trigger event 1e for the measurement that the UE had stored from system information, so a MEASUREMENT REPORT message shall be received for measurement identity = 10 (step 6a) as well. The order of steps 6 and 6a is not important and could be reversed.

Next, SS sends a PHYSICAL CHANNEL RECONFIGURATION message (step 7). SS configures common physical channels for both the uplink and the downlink directions. The UE shall transit to CELL_FACH state and then reply with a PHYSICAL CHANNEL RECONFIGURATION COMPLETE message (step 8). SS waits and checks the uplink RACH to confirm that no MEASUREMENT REPORT messages are received (step 9).

SS transmits then a RADIO BEARER RECONFIGURATION message to the UE, to move it to CELL_DCH state (step 9a). The UE shall move to that state, and transmit a RADIO BEARER RECONFIGURATION COMPLETE message to SS (step 9b). Shortly after, a MEASUREMENT REPORT message shall be received that has been triggered by cell 2, i.e. the UE shall have deleted the measurement configured through the MEASUREMENT CONTROL message of step 5, and instead apply the measurement configured in SIB12: a MEASUREMENT REPORT message with measurement identity 10 shall be received while no such message with measurement identity 11 shall be sent by the UE (step 9c).

SS transmits MEASUREMENT CONTROL message on the downlink DCCH, to configure intra-frequency measurements with validity CELL_DCH (step 10). The UE shall send a MEASUREMENT REPORT message (with IE “Measurement identity” = 12) to the SS triggered by cell 2 (step 14).

SS transmits a PHYSICAL CHANNEL RECONFIGURATION message to the UE to move it to CELL_FACH state (step 14a). The UE shall move to that state and transmit a PHYSICAL CHANNEL RECONFIGURATION COMPLETE message to SS (step 14b). SS shall wait and check that no MEASUREMENT REPORT messages are detected on the uplink DCCH (step 14c).

SS transmits a RADIO BEARER RECONFIGURATION message to the UE, to move it to CELL_DCH state (step 14d). The UE shall move to that state, and transmit a RADIO BEARER RECONFIGURATION COMPLETE message to SS (step 14e). Shortly after, a MEASUREMENT REPORT message shall be received that has been triggered by cell 2, i.e. the UE shall have retrieved the measurement configured through the MEASUREMENT CONTROL message of step 10 (step 14f)..

Following the reception of the MEASUREMENT REPORT messages, SS commands the UE using MEASUREMENT CONTROL message to release measurement control information stored in "measurement identity" = 12 (step 16). Thereafter, SS verifies that no MEASUREMENT REPORT messages are detected on the uplink DCCH with "measurement identity" = 12 (step 16a). After this requirement is satisfied, SS sends MEASUREMENT CONTROL on the downlink DCCH once more (step 17). This message is identical to the one sent in step 10 (see specific message content). A MEASUREMENT REPORT message shall be received from the UE triggered by cell 2 (step 17a).

SS transmits a PHYSICAL CHANNEL RECONFIGURATION message on the downlink DCCH and configures common physical channel (step 18). The UE shall transit to CELL_FACH state and then respond with a PHYSICAL CHANNEL RECONFIGURATION COMPLETE message (step 19). SS monitors the uplink DCCH once more to verify that no MEASUREMENT REPORT messages are detected (step 20). SS modifies the downlink transmission power of the respect cells according to the settings in columns "T1" in table 8.4.1.7-1. System information block type 11 and System Information Block type 12 for cell 2 shall be different from the default settings according to what is defined in the specific message content part of this section (step 21). The UE shall initiate a cell re-selection procedure. This is verified in the SS when a CELL UPDATE message is received on the uplink CCCH with the "cell update cause" IE set to "cell reselection" (step 22). SS transmits a CELL UPDATE CONFIRM message, which includes "New C-RNTI", on the DCCH (step 23). Then the UE shall reply with UTRAN MOBILITY INFORMATION CONFIRM message (step 23a). Next, SS sends a RADIO BEARER RECONFIGURATION message on the downlink DCCH, assigning dedicated physical channels in both uplink and downlink directions (step 24). The UE shall respond with a RADIO BEARER RECONFIGURATION COMPLETE message and then return to CELL_DCH state (step 25). SS modifies the downlink transmission power of all cells according to the settings in columns "T2" in table 8.4.1.7-1. UE shall then send MEASUREMENT REPORT messages reporting cell 3’s CPICH RSCP according to the content in System Information Block type 12 messages broadcasted in cell 2 (step 21).SS transmits a MEASUREMENT CONTROL message (step 27) whereby the measurement identity is set to the same value as that in the SIB type 12 messages (step 21). UE shall send MEASUREMENT REPORT message (step 28) reporting cell 3’s CPICH RSCP according to the MEASUREMENT CONTROL message (step 27).

NOTE: If the UE fails the test because of a failure to reselect to a right cell, then the operator may re-run the test.

Expected Sequence

Step

Direction

Message

Comment

UE

SS

1

System Information Block type 11 and 12, Master Information Block, Scheduling Block 1

UE is initially in PS-DCCH+DTCH_FACH (state 6-11) in cell 1. System Information Block type 11 and 12 messages are changed with respect to the default contents according to the descriptions in "Specific Message Contents" clause.

1a

SYSTEM INFORMATION CHANGE INDICATION

2

RADIO BEARER RECONFIGURATION

SS configures dedicated physical channels.

3

RADIO BEARER RECONFIGURATION COMPLETE

UE shall move to CELL_DCH state.

4

MEASUREMENT REPORT

Reports cell 2’s CPICH RSCP measurement value, with “measurement identity” IE set to “10”.

5

MEASUREMENT CONTROL

Cell 3 is added to the list of monitored set of the UE.

6

MEASUREMENT REPORT

Cell 3 shall trigger the event 1e configured in the measurement identity 11.

NOTE: due to ambiguity in 25.331 – two interpretations can be given. These are shown in the specific message contents below.

6a

MEASUREMENT REPORT

Cell 3 shall also trigger the event 1e configured in the measurement identity 10. The order of steps 6 and 6a could be reversed.

7

PHYSICAL CHANNEL RECONFIGURATION

SS configures PRACH and S-CCPCH physical channels.

8

PHYSICAL CHANNEL RECONFIGURATION COMPLETE

UE shall move to CELL_FACH state.

9

SS waits and checks that no MEASUREMENT REPORT messages are sent by UE.

9a

RADIO BEARER RECONFIGURATION

SS configures dedicated physical channels.

9b

RADIO BEARER RECONFIGURATION COMPLETE

UE shall move to CELL_DCH state.

9c

MEASUREMENT REPORT

UE shall report cell 2’s CPICH RSCP measurement value, with “measurement identity” IE set to “10”.

9d

Void

9e

Void

10

MEASUREMENT CONTROL

SS instructs the UE to setup intra-frequency measurement and reporting for cell 2 (already available as neighbouring cell in UE). Measurement validity" IE is set to CELL_DCH state.

11

12

Void

13

Void

13a

Void

14

MEASUREMENT REPORT

UE reports cell 2’s measured results for CPICH RSCP, with “measurement identity” IE set to “12”.

14a

PHYSICAL CHANNEL RECONFIGURATION

SS configures PRACH and S-CCPCH physical channels.

14b

PHYSICAL CHANNEL RECONFIGURATION COMPLETE

UE shall move to CELL_FACH state.

14c

SS waits and check that no MEASUREMENT REPORT messages are sent by the UE.

14d

RADIO BEARER RECONFIGURATION

SS configures dedicated physical channels.

14e

RADIO BEARER RECONFIGURATION COMPLETE

UE shall move to CELL_DCH state.

14f

MEASUREMENT REPORT

UE shall have retrieved and resumed the measurement set up through the MEASUREMENT CONTROL of step 10.The “measurement identity” IE shall be set to “12”.

15

Void

16

MEASUREMENT CONTROL

Terminate all the intra-frequency measurement and reporting activities related to "measurement identity" = 12.

16a

SS waits and verifies that UE stops transmitting MEASUREMENT REPORT messages with “measurement identity” = 12.

17

MEASUREMENT CONTROL

This message is the same as in step 10.

17a

MEASUREMENT REPORT

UE shall transmit a MEASUREMENT REPORT message triggered by cell 2, with “measurement identity” IE set to “12”.

17b

Void

18

PHYSICAL CHANNEL RECONFIGURATION

Allocates common physical channels.

19

PHYSICAL CHANNEL RECONFIGURATION COMPLETE

UE shall move to CELL_FACH state.

20

SS checks that no MEASUREMENT REPORT messages are received.

21

System Information Block type 11

System Information Block type 12

SS sends SIB11 and SIB12 with specific values to Cell2.

SS reconfigures the downlink transmission power settings for cells 1 to 3 according to column "T1" in table 8.4.1.7.

22

CELL UPDATE

UE shall re-selects to cell 2 and then perform a cell update procedure.

23

CELL UPDATE CONFIRM

UE shall stay in CELL_FACH state.

23a

UTRAN MOBILITY INFORMATION CONFIRM

24

RADIO BEARER RECONFIGURATION

Dedicated physical channels are assigned to the UE in this message.

25

RADIO BEARER RECONFIGURATION COMPLETE

UE shall return to CELL_DCH state. UE shall not send Measurement Report message with “measurement identity” = ‘12’.

25a

SS reconfigures the downlink transmission power settings of all cells according to column “T2” in table 8.4.1.7-1.

26

MEASUREMENT REPORT

UE begins to report cell 3’s measured results for CPICH RSCP, with “measurement identity” IE set to “1”.

27

MEASUREMENT CONTROL

28

MEASUREMENT REPORT

UE shall transmit a MEASUREMENT REPORT message triggered by cell 3, with “measurement identity” IE set to “1”.

Specific Message Content

System Information Block type 1 (FDD)

Use the default system information block with the same type specified in clause 6.1 of TS 34.108, with the following exceptions:

Information Element

Value/remark

– UE Timers and constants in connected mode

– T312

2

Master Information Block (Step 1)

Information Element

Value/Remarks

MIB Value Tag

A valid MIB value tag as defined in TS 25.331 that is different from the previous value

SB 1 Cell Value tag

Set to (Current SB 1 value tag + 1)

Scheduling Block 1 (Step 1)

Information Element

Value/remark

SIB 11 Cell Value tag

Set to (Current SIB 11 value tag + 1)

SIB 12 Cell Value tag

Set to (Current SIB 12 value tag + 1)

System Information Block type 11 for cell 1 (Step 1)

All messages content below shall use the same content as described in default message content specified in clause 6.1 of TS 34.108, with the following exception:

Information Element

Value/remark

SIB12 indicator

TRUE

FACH measurement occasion info

Not Present

Measurement control system information

– Use of HCS

Not used

– Cell selection and reselection quality measure

CPICH RSCP

– Intra-frequency measurement system information

– Intra-frequency measurement identity

Not present

– Intra-frequency cell info list

– CHOICE intra-frequency cell removal

Not present

– New intra-frequency cells

– Intra-frequency cell id

1

– Cell info

– Cell individual offset

Not present

– Reference time difference to cell

Not present

– Read SFN indicator

FALSE

– CHOICE mode

FDD

– Primary CPICH info

– Primary scrambling code

Refer to clause titled "Default settings for cell No.1 (FDD)" in clause 6.1.4 of TS34.108

– Primary CPICH Tx power

Not present

– TX Diversity indicator

FALSE

– Cell Selection and Re-selection info

Not present

– Cells for measurement

Not present

– Intra-frequency measurement quantity

Not present

– Intra-frequency reporting quantity for RACH reporting

Not present

– Maximum number of reported cells on RACH

Not present

– Reporting information for state CELL_DCH

Not present

– Inter-frequency measurement system information

As per 34.108 clause 6.1.0b – Contents of System Information Block type 11 (FDD)

– Inter-RAT measurement system information

Not present

– Traffic volume measurement system information

Not Present

System Information Block type 12 for cell 1 (Step 1)

Information Element

Value/remark

FACH measurement occasion info

Not Present

Measurement control system information

– Use of HCS

Not used

– Cell selection and reselection quality measure

CPICH RSCP

– Intra-frequency measurement system information

– Intra-frequency measurement identity

10

– Intra-frequency cell info list

– CHOICE intra-frequency cell removal

Not present

– New intra-frequency cells

– Intra-frequency cell id

2

– Cell info

– Cell individual offset

Not present

– Reference time difference to cell

Not present

– Read SFN Indicator

FALSE

– CHOICE mode

FDD

– Primary CPICH Info

– Primary Scrambling Code

Refer to clause titled "Default settings for cell No.2 (FDD)" in clause 6.1.4 of TS 34.108

– Primary CPICH TX power

Not Present

– TX Diversity Indicator

FALSE

– Cell selection and Re-selection info

Not Present

– Cells for measurement

Not Present

– Intra-frequency measurement quantity

– Filter Coefficient

Not present

– CHOICE mode

FDD

– Measurement quantity

CPICH RSCP

– Intra-frequency reporting quantity for RACH reporting

Not present

– Maximum number of reported cells on RACH

No report

– Reporting information for state CELL_DCH

– Intra-frequency reporting quantity

– Reporting quantities for active set cells

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CHOICE mode

FDD

– CPICH Ec/No reporting indicator

FALSE

– CPICH RSCP reporting indicator

FALSE

– Pathloss reporting indicator

FALSE

– Reporting quantities for monitored set cells

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

TRUE

– CHOICE mode

FDD

– CPICH Ec/No reporting indicator

FALSE

– CPICH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting quantities for detected cells

Not present

– Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged mode RLC

– Periodic Reporting/Event Trigger Reporting Mode

Event trigger

– CHOICE report criteria

Intra-frequency measurement reporting criteria

– Parameter required for each event

– Intra-frequency event identity

1e

– Triggering condition 1

Not present

– Triggering condition 2

Monitored set cells

– Reporting range constant

Not present

– Cells forbidden to affect reporting range

Not present

– W

Not present

– Hysteresis

0 (0 dB)

– Threshold used frequency

-80 dBm

– Reporting deactivation threshold

Not present

– Replacement activation threshold

Not present

– Time to trigger

0

– Amount of reporting

Not Present

– Reporting Interval

Not Present

– Reporting cell status

– CHOICE reported cells

Report cells within monitored set cells on used frequency

– Maximum number of reported cells

3

– Inter-frequency measurement system information

Not Present

– Inter-RAT measurement system information

Not Present

– Traffic volume measurement system information

Not Present

SYSTEM INFORMATION CHANGE INDICATION (Step 1a)

Information Element

Value/Remarks

BCCH modification info

– MIB Value Tag

A valid MIB value tag as defined in TS 25.331 that is different from the previous value

– BCCH modification time

Not Present

RADIO BEARER RECONFIGURATION (Step 2, Step 9a, Step 14d and Step 24)

Use the same message type found in Annex A, with condition set to A4.

MEASUREMENT REPORT (Steps 4 and 9c)

Information Element

Value/remark

Measurement identity

Check to see if set to 10

Measured Results

– CHOICE measurement

Check to see if set to "Intra-frequency measured results list"

– Intra-frequency measurement results

– Cell measured results

– Cell Identity

Check to see if this IE is absent

– Cell synchronisation information

Check to see if this IE is absent

– Primary CPICH Info

– Primary Scrambling Code

Check to see if it’s the same code for cell 2

– CPICH Ec/No

Check to see if this IE is absent

– CPICH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

Measured Results on RACH

Check to see if this IE is absent

Additional measured results

Check to see if this IE is absent

Event Results

– CHOICE event result

Check to see if it’s set to ‘Intra-frequency measurement event results’

– Intra-frequency event identity

Check to see if this IE is set to ‘1e’

– Cell measurement event results

– Primary CPICH info

– Primary scrambling code

Check to see if it’s the same code for cell 2

MEASUREMENT CONTROL (Step 5)

Information Element

Value/remark

Measurement Identity

11

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Event Trigger

Additional measurements list

Not Present

CHOICE measurement type

Intra-frequency measurement

– Intra-frequency cell info list

– CHOICE intra-frequency cell removal

Remove no intra-frequency cells

– New intra-frequency info list

– Intra-frequency cell id

3

– Cell info

– Cell individual offset

0 dB

– Reference time difference to cell

Not Present

– Read SFN Indicator

FALSE

– CHOICE mode

FDD

– Primary CPICH Info

– Primary Scrambling Code

Set to same code as used for cell 3

– Primary CPICH TX power

Not Present

– TX Diversity Indicator

FALSE

– Cells selection and Re-selection info

Not Present

– Cells for measurement

– Intra-frequency cell id

3

– Intra-frequency measurement quantity

– Filter Coefficient

Not Present

– Measurement quantity

CPICH RSCP

– Intra-frequency reporting quantity

– Reporting quantities for active set cells

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CPICH Ec/No reporting indicator

FALSE

– CPICH RSCP reporting indicator

FALSE

– Pathloss reporting indicator

FALSE

– Reporting quantities for monitored set cells

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

TRUE

– CPICH Ec/No reporting indicator

FALSE

– CPICH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting quantities for detected cells

Not present

– Reporting cell status

Not present

– Measurement validity

Not present

– CHOICE report criteria

Intra-frequency measurement criteria

– Parameters required for each event

– Intra-frequency event identity

1e

– Triggering condition 1

Not Present

– Triggering condition 2

Monitored set cells

– Hysteresis

0 (0 dB)

– Threshold used frequency

-90 dBm

– Time to Trigger

0

– Amount of reporting

Not Present

– Reporting interval

Not Present

– Reporting cell status

– CHOICE reported cells

Report cells within monitored set cells on used frequency

– Maximum number of reported cells

3

DPCH compressed mode status info

Not Present

MEASUREMENT REPORT (Step 6)

NOTE: Due to ambiguity in 25.331 – two interpretations can be given for MEASUREMENT REPORT

Information Element

Value/remark

Measurement identity

Check to see if set to 11

Measured Results

– CHOICE measurement

Check to see if set to "Intra-frequency measured results list"

– Intra-frequency measurement results

– Cell measured results

– Cell Identity

Check to see if this IE is absent

– Cell synchronisation information

Check to see if this IE is absent

– Primary CPICH Info

– Primary Scrambling Code

Check to see if it’s the same code for cell 2

– CPICH Ec/No

Check to see if this IE is absent

– CPICH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

– Cell measured results

– Cell Identity

Check to see if this IE is absent

– Cell synchronisation information

Check to see if this IE is absent

– Primary CPICH Info

– Primary Scrambling Code

Check to see if it’s the same code for cell 3

– CPICH Ec/No

Check to see if this IE is absent

– CPICH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

Measured Results on RACH

Check to see if this IE is absent

Additional measured results

Check to see if this IE is absent

Event Results

– CHOICE event result

Check to see if it’s set to ‘Intra-frequency measurement event results’

– Intra-frequency event identity

Check to see if this IE is set to ‘1e’

– Cell measurement event results

– Primary CPICH info

– Primary scrambling code

Check to see if it’s the same code for cell 3

MEASUREMENT REPORT (Step 6)

NOTE: Due to ambiguity in 25.331 – two interpretations can be given for MEASUREMENT REPORT

Information Element

Value/remark

Measurement identity

Check to see if set to 11

Measured Results

– CHOICE measurement

Check to see if set to "Intra-frequency measured results list"

– Intra-frequency measurement results

– Cell measured results

– Cell Identity

Check to see if this IE is absent

– Cell synchronisation information

Check to see if this IE is absent

– Primary CPICH Info

– Primary Scrambling Code

Check to see if it’s the same code for cell 3

– CPICH Ec/No

Check to see if this IE is absent

– CPICH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

Measured Results on RACH

Check to see if this IE is absent

Additional measured results

Check to see if this IE is absent

Event Results

– CHOICE event result

Check to see if it’s set to ‘Intra-frequency measurement event results’

– Intra-frequency event identity

Check to see if this IE is set to ‘1e’

– Cell measurement event results

– Primary CPICH info

– Primary scrambling code

Check to see if it’s the same code for cell 3

MEASUREMENT REPORT (Step 6a)

Information Element

Value/remark

Measurement identity

Check to see if set to 10

Measured Results

– CHOICE measurement

Check to see if set to "Intra-frequency measured results list"

– Intra-frequency measurement results

– Cell measured results

– Cell Identity

Check to see if this IE is absent

– Cell synchronisation information

Check to see if this IE is absent

– Primary CPICH Info

– Primary Scrambling Code

Check to see if it’s the same code for cell 2

– CPICH Ec/No

Check to see if this IE is absent

– CPICH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

– Cell measured results

– Cell Identity

Check to see if this IE is absent

– Cell synchronisation information

Check to see if this IE is absent

– Primary CPICH Info

– Primary Scrambling Code

Check to see if it’s the same code for cell 3

– CPICH Ec/No

Check to see if this IE is absent

– CPICH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

Measured Results on RACH

Check to see if this IE is absent

Additional measured results

Check to see if this IE is absent

Event Results

– CHOICE event result

Check to see if it’s set to ‘Intra-frequency measurement event results

– Intra-frequency event identity

Check to see if this IE is set to ‘1e’

– Cell measurement event results

– Primary CPICH info

– Primary scrambling code

Check to see if it’s the same code for cell 3

PHYSICAL CHANNEL RECONFIGURATION (Steps 7, 14a and 18)

Use the same message sub-type found in clause 9 of TS 34.108, which is entitled "Packet to CELL_FACH from CELL_DCH in PS".

MEASUREMENT CONTROL (Steps 10 and 17)

Information Element

Value/remark

Measurement Identity

12

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Event Trigger

Additional measurements list

Not Present

CHOICE measurement type

Intra-frequency measurement

– Intra-frequency cell info list

Not Present

– Intra-frequency measurement quantity

– Filter Coefficient

Not Present

– Measurement quantity

CPICH RSCP

– Intra-frequency reporting quantity

– Reporting quantities for active set cells

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CPICH Ec/No reporting indicator

FALSE

– CPICH RSCP reporting indicator

FALSE

– Pathloss reporting indicator

FALSE

– Reporting quantities for monitored set cells

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

TRUE

– CPICH Ec/No reporting indicator

FALSE

– CPICH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting quantities for detected cells

Not present

– Reporting cell status

Not present

– Measurement validity

– UE state

CELL_DCH

– CHOICE report criteria

Intra-frequency measurement criteria

– Parameters required for each event

– Intra-frequency event identity

1e

– Triggering condition 1

Not Present

– Triggering condition 2

Monitored set cells

– Hysteresis

0 (0 dB)

– Threshold Used Frequency

-80 dBm

– Time to Trigger

0

– Amount of reporting

Not Present

– Reporting interval

Not Present

– Reporting cell status

– CHOICE reported cell

Report cells within monitored set cells on used frequency

– Maximum number of reported cells

1

DPCH compressed mode status info

Not Present

MEASUREMENT REPORT (Steps 14, 14f and 17a)

Information Element

Value/remark

Measurement identity

Check to see if set to 12

Measured Results

– CHOICE measurement

Check to see if set to "Intra-frequency measured results list"

– Intra-frequency measurement results

– Cell measured results

– Cell Identity

Check to see if this IE is absent

– Cell synchronisation information

Check to see if this IE is absent

– Primary CPICH Info

– Primary Scrambling Code

Check to see if it’s the same code for cell 2

– CPICH Ec/No

Check to see if this IE is absent

– CPICH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

Measured Results on RACH

Additional measured results

Check to see if this IE is absent

Event Results

– CHOICE event result

Check to see if it’s set to ‘Intra-frequency measurement event results

– Intra-frequency event identity

Check to see if this IE is set to ‘1e’

– Cell measurement event results

– Primary CPICH info

– Primary scrambling code

Check to see if it’s the same code for cell 2

MEASUREMENT CONTROL (Step 16)

Information Element

Value/remark

Measurement Identity

12

Measurement Command

Release

Measurement Reporting Mode

Not Present

Additional measurements list

Not Present

CHOICE Measurement type

Not Present

DPCH compressed mode status info

Not Present

System Information Block type 11 for cell 2 (Step 21)

All messages content below shall use the same content as described in default message content specified in clause 6.1 of TS 34.108, with the following exception:

Information Element

Value/Remark

SIB12 indicator

TRUE

FACH measurement occasion info

Not Present

Measurement control system information

– Use of HCS

Not used

– Cell selection and reselection quality measure

CPICH RSCP

– Intra-frequency measurement system information

– Intra-frequency measurement identity

Not present

– Intra-frequency cell info list

– CHOICE intra-frequency cell removal

Not Present

– New intra-frequency cells

– Intra-frequency cell id

2

– Cell info

– Cell individual offset

Not Present

– Reference time difference to cell

Not present

– Read SFN indicator

FALSE

– CHOICE mode

FDD

– Primary CPICH info

– Primary scrambling code

Refer to clause titled "Default settings for cell No.2 (FDD)" in clause 6.1.4

– Primary CPICH Tx power

Not present

– TX Diversity indicator

FALSE

– Cell Selection and Re-selection info

Not present

– Intra-frequency cell id

1

– Cell info

– Cell individual offset

Not Present

– Reference time difference to cell

Not present

– Read SFN indicator

TRUE

– CHOICE mode

FDD

– Primary CPICH info

– Primary scrambling code

Refer to clause titled "Default settings for cell No.1 (FDD)" in clause 6.1.4

– Primary CPICH Tx power

Not present

– TX Diversity indicator

FALSE

– Cell Selection and Re-selection info

Not present

– Intra-frequency cell id

3

– Cell info

– Cell individual offset

Not Present

– Reference time difference to cell

Not present

– Read SFN indicator

TRUE

– CHOICE mode

FDD

– Primary CPICH info

– Primary scrambling code

Refer to clause titled "Default settings for cell No.3 (FDD)" in clause 6.1.4

– Primary CPICH Tx power

Not present

– TX Diversity indicator

FALSE

– Cell Selection and Re-selection info

Not present

– Cells for measurement

Not present

– Intra-frequency measurement quantity

– Filter coefficient

Not Present

– CHOICE mode

FDD

– Measurement quantity

CPICH RSCP

– Intra-frequency reporting quantity for RACH reporting

Not present

– Maximum number of reported cells on RACH

Not present

– Reporting information for state CELL_DCH

Not present

System Information Block type 12 for cell 2 (Step 21)

Information Element

Value/Remark

FACH measurement occasion info

Not Present

Measurement control system information

– Use of HCS

Not used

– Cell selection and reselection quality measure

CPICH RSCP

– Intra-frequency measurement system information

– Intra-frequency measurement identity

Not present

– Intra-frequency cell info list

Not Present

– Intra-frequency measurement quantity

– Filter coefficient

Not Present

– CHOICE mode

FDD

– Measurement quantity

CPICH RSCP

– Intra-frequency reporting quantity for RACH reporting

Not present

– Maximum number of reported cells on RACH

Not present

– Reporting information for state CELL_DCH

– Intra-frequency reporting quantity

– Reporting quantities for active set cells

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

TRUE

– CHOICE mode

FDD

– CPICH Ec/N0 reporting indicator

FALSE

– CPICH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting quantities for monitored set cells

– Cell synchronisation information reporting indicator

TRUE

– Cell identity reporting indicator

TRUE

– CHOICE mode

FDD

– CPICH Ec/N0 reporting indicator

FALSE

– CPICH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting quantities for detected set cells

Not Present

– Measurement reporting mode

– Measurement Report Transfer Mode

Acknowledged mode RLC

– Periodic Reporting/Event Trigger Reporting Mode

Event trigger

– CHOICE report criteria

Intra-frequency measurement reporting criteria

– Intra-frequency measurement reporting criteria

– Intra-frequency event identity

1a

– Triggering condition 2

Monitored set cells

– Reporting Range Constant

10 (5dB)

– Cells forbidden to affect Reporting range

Not Present

– W

0

– Hysteresis

0 (0 dB)

– Threshold Used Frequency

Not Present

– Reporting deactivation threshold

2

– Replacement activation threshold

Not Present

– Time to trigger

640

– Amount of reporting

4

– Reporting interval

4000

– Reporting cell status

– CHOICE reported cell

Report cell within active set and/or monitored set cells on used frequency

– Maximum number of reported cells

3

– Inter-frequency measurement system information

Not present

– Inter-RAT measurement system information

Not present

– Traffic volume measurement system information

Not Present

– UE internal measurement system information

Not Present

CELL UPDATE (Step 22)

Information Element

Value/remark

U-RNTI

Check to see if set to the previous assigned U-RNTI value

START List

Check to see if it is present

AM_RLC error indication(RB2, RB3 or RB4)

Checked to see if it is set to FALSE

AM_RLC error indication(RB>4)

Checked to see if it is set to FALSE

Cell Update Cause

Check to see if set to "Cell Reselection"

RB timer indicator

– T314 expired

Checked to see if it is set to ‘FALSE’

– T315 expired

Checked to see if it is set to ‘FALSE’

Measured results on RACH

Check to see if it is absent

CELL UPDATE CONFIRM (Step 23)

Use the default message content of the same message type in Annex A, with the following exceptions.

Information Element

Value/Remarks

New C-RNTI

‘1010 1010 1010 1010’

UTRAN MOBILITY INFORMATION CONFIRM (Step 23a)

Only the message type is checked.

MEASUREMENT REPORT (Step 26)

Information Element

Value/Remarks

Measurement identity

Check to see if set to 1

Measured Results

– CHOICE measurement

Check to see if set to "Intra-frequency measured results list"

– Intra-frequency measurement results

– Cell measured results

– Cell Identity

Check to see if this IE is absent

– Cell synchronisation information

Check to see if this IE is absent

– Primary CPICH Info

– Primary Scrambling Code

Check to see if it’s the same code for cell 2

– CPICH Ec/No

Check to see if this IE is absent

– CPICH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

– Cell Identity

Check to see if this IE is absent

– Cell synchronisation information

Check to see if this IE is present

– Primary CPICH Info

– Primary Scrambling Code

Check to see if it’s the same code for cell 3

– CPICH Ec/No

Check to see if this IE is absent

– CPICH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

– Cell Identity

Check to see if this IE is absent

– Cell synchronisation information

Check to see if this IE is present

– Primary CPICH Info

– Primary Scrambling Code

Check to see if it’s the same code for cell 1

– CPICH Ec/No

Check to see if this IE is absent

– CPICH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

Measured Results on RACH

Check to see if this IE is absent

Additional measured results

Check to see if this IE is absent

Event Results

– CHOICE event result

Check to see if it’s set to ‘Intra-frequency measurement event results’

– Intra-frequency event identity

Check to see if this IE is set to ‘1a’

– Cell measurement event results

– CHOICE mode

FDD

– Primary CPICH info

– Primary scrambling code

Check to see if it’s the same code for cell 3

NOTE: Cells 2 and 3 can be received in any order

MEASUREMENT CONTROL (Step 27)

Information Element

Value/remark

Measurement Identity

1

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Event Trigger

Additional measurements list

Not Present

CHOICE measurement type

Intra-frequency measurement

– Intra-frequency cell info list

– CHOICE intra-frequency cell removal

Remove no intra-frequency cells

– New intra-frequency info list

Not present

– Cells for measurement

– Intra-frequency cell id

3

– Intra-frequency measurement quantity

– Filter Coefficient

Not Present

– Measurement quantity

CPICH RSCP

– Intra-frequency reporting quantity

– Reporting quantities for active set cells

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CPICH Ec/No reporting indicator

FALSE

– CPICH RSCP reporting indicator

FALSE

– Pathloss reporting indicator

FALSE

– Reporting quantities for monitored set cells

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

TRUE

– CPICH Ec/No reporting indicator

FALSE

– CPICH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting quantities for detected cells

Not present

– Reporting cell status

Not present

– Measurement validity

Not present

– CHOICE report criteria

Intra-frequency measurement criteria

– Parameters required for each event

– Intra-frequency event identity

1e

– Triggering condition 1

Not Present

– Triggering condition 2

Monitored set cells

– Hysteresis

0 (0 dB)

– Threshold used frequency

-90 dBm

– Time to Trigger

0

– Amount of reporting

Not Present

– Reporting interval

Not Present

– Reporting cell status

– CHOICE reported cells

Report cells within monitored set cells on used frequency

– Maximum number of reported cells

1

DPCH compressed mode status info

Not Present

MEASUREMENT REPORT (Step 28)

Information Element

Value/remark

Measurement identity

Check to see if set to 1

Measured Results

– CHOICE measurement

Check to see if set to "Intra-frequency measured results list"

– Intra-frequency measurement results

– Cell measured results

– Cell Identity

Check to see if this IE is absent

– Cell synchronisation information

Check to see if this IE is absent

– CHOICE mode

FDD

– Primary CPICH Info

– Primary Scrambling Code

Check to see if it’s the same code for cell 3

– CPICH Ec/No

Check to see if this IE is absent

– CPICH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

Measured Results on RACH

Check to see if this IE is absent

Additional measured results

Check to see if this IE is absent

Event Results

– CHOICE event result

Check to see if it’s set to ‘Intra-frequency measurement event results’

– Intra-frequency event identity

Check to see if this IE is set to ‘1e’

– Cell measurement event results

– Primary CPICH info

– Primary scrambling code

Check to see if it’s the same code for cell 3

8.4.1.7.5 Test Requirement

After step 3 the UE shall report cell 2’s CPICH RSCP value by transmitting MEASUREMENT REPORT messages.

After step 5 the UE shall transmit two MEASUREMENT REPORT messages which contain measured results of cell 3’s CPICH RSCP value only, one for measurement identity 10 and one for measurement identity 11.

After step 9 and step 11 the UE shall not transmit MEASUREMENT REPORT messages, which pertain to intra-frequency type measurement reporting.

After step 9b, the UE shall transmit a MEASUREMENT REPORT according to what is broadcast in SIB 11 and 12 of cell 1, and MEASUREMENT REPORT message pertaining to the MEASUREMENT CONTROL message that it had received in step 5.

After steps 13 and 14e, the UE shall resume the measurement and reporting activities as specified in MEASUREMENT CONTROL message received in step 10. The UE shall transmit MEASUREMENT REPORT messages, containing measured results of cell 2’s CPICH RSCP value.

After step 16 the UE shall stop measurement activities pertaining to event triggered reporting of cell 2’s CPICH RSCP, no MEASUREMENT REPORT messages shall be detectable by the SS on the uplink DCCH with “measurement identity” = 12.

After step 17, the UE shall transmit a MEASUREMENT REPORT message to the SS as specified in the MEASUREMENT CONTROL message received in step 17.

After step 21 the UE shall re-select to cell 2 and initiate a cell update procedure. SS shall receive a CELL UPDATE message on the uplink CCCH of cell 2, with the "cell update cause" IE stated as "cell re-selection".

After step 23, the UE shall transmit UTRAN MOBILITY INFORMATION CONFIRM message on the uplink DCCH AM RLC.

After step 25, UE shall not send MEASUREMENT REPORT message with “measurement identity” = ‘12’.

After step 25a the UE shall report cell 3’s CPICH RSCP value by transmitting MEASUREMENT REPORT messages.

After step 27, UE shall send MEASUREMENT REPORT message with “measurement identity” = ‘1’.

8.4.1.7a Measurement Control and Report: Intra-frequency measurement for transition from CELL_FACH to CELL_DCH state (TDD)

8.4.1.7a.1 Definition

8.4.1.7a.2 Conformance requirement

Upon transition from CELL_FACH to CELL_DCH state:

1> if intra-frequency measurements applicable to CELL_DCH state are stored in the variable MEASUREMENT_IDENTITY:

2> if the cell in which the UE transited from CELL_FACH state is included in the active set for the CELL_DCH state, the UE shall:

3> resume the measurement reporting.

2> otherwise:

3> the UE should not resume the measurement reporting. If the UE does not resume the measurement reporting, the measurement shall be restarted when a MEASUREMENT CONTROL message is received with the corresponding measurement identity.

Upon cell reselection while in CELL_FACH/CELL_PCH/URA_PCH state and the cell reselection has occurred after the measurement control information was stored, the UE shall:

1> delete all measurements of type intra-frequency, inter-frequency, and inter-RAT associated with the variable MEASUREMENT_IDENTITY;

1> delete the traffic volume measurements that have not been set up or modified through a MEASUREMENT CONTROL message.

Upon reception of a MEASUREMENT CONTROL message the UE shall perform actions specified in subclause 8.6 unless otherwise specified below.

The UE shall:

1> read the IE "Measurement command";

1> if the IE "Measurement command" has the value "setup":

2> store this measurement in the variable MEASUREMENT_IDENTITY according to the IE "measurement identity", first releasing any previously stored measurement with that identity if that exists;

2> if the measurement type is quality, UE internal, intra-frequency, inter-frequency or inter-RAT:

3> if the UE is in CELL_FACH state:

4> the UE behaviour is not specified.

2> for measurement types "inter-RAT measurement" or "inter-frequency measurement" that require measurements on a frequency other than the actually used frequency:

2> for measurement type "inter-frequency measurement" that requires measurements only on the same frequency as the actually used frequency:

2> for measurement type "UE positioning measurement":

2> for any other measurement type:

3> if the measurement is valid in the current RRC state of the UE:

4> begin measurements according to the stored control information for this measurement identity.

1> if the IE "Measurement command" has the value "modify":

2> for all IEs present in the MEASUREMENT CONTROL message:

3> if a measurement was stored in the variable MEASUREMENT_IDENTITY associated to the identity by the IE "measurement identity":

4> if the measurement type is quality, UE internal, intra-frequency, inter-frequency or inter-RAT:

5> if the UE is in CELL_FACH state:

6> the UE behaviour is not specified.

4> if measurement type is set to "intra-frequency measurement", for any of the optional IEs "Intra-frequency measurement objects list", "Intra-frequency measurement quantity", "Intra-frequency reporting quantity", "Measurement Validity", "report criteria" and "parameters required for each event" (given "report criteria" is set to "intra-frequency measurement reporting criteria") that are present in the MEASUREMENT CONTROL message:

5> replace the corresponding information (the IEs listed above and all their children) stored in variable MEASUREMENT_IDENTITY associated to the identity indicated by the IE "measurement identity" with the one received in the MEASUREMENT CONTROL message;

5> leave all other stored information elements unchanged in the variable MEASUREMENT_IDENTITY.

1> if the IE "measurement command" has the value "release":

2> terminate the measurement associated with the identity given in the IE "measurement identity";

2> clear all stored measurement control information related associated to this measurement identity in variable MEASUREMENT_IDENTITY.

If the IE "Reporting Cell Status" is received, the UE shall set the IE "Measured Results" in MEASUREMENT REPORT as follows. The UE shall:

1> for intra-frequency measurement and inter-frequency measurement:

2> include the IE "Cell Measured Results" for cells (excluding cells of another RAT) that satisfy the condition (such as "Report cells within active set") specified in the IE "Reporting Cell Status", in descending order by the measurement quantity"

If the IE "Cells for measurement" has been included in a MEASUREMENT CONTROL message, only monitored set cells explicitly indicated for a given intra-frequency (resp. inter-frequency, interRAT) measurement by the IE "Cells for measurement" shall be considered for measurement. If the IE "Cells for measurement" has not been included in a MEASUREMENT CONTROL message, all of the intra-frequency (resp. inter-frequency, inter RAT) cells stored in the variable CELL_INFO_LIST shall be considered for measurement. The IE "Cells for measurement" is not applicable to active set cells or virtual active set cells e.g. when the triggering condition refers to active set cells, the UE shall consider all active set cells in the CELL_INFO_LIST for measurement irrespective if these cells are explicitly indicated by the IE "Cells for measurement".

Reference

3GPP TS 25.331, clause 8.4.1.3, 8.4.1.6a, 8.4.1.7.1, 8.4.0 and 8.6.7.9

8.4.1.7a.3 Test Purpose

– To confirm that UE retrieves stored measurement control information for intra-frequency measurement type with "measurement validity" assigned to "CELL_DCH", after it enters CELL_DCH state from CELL_FACH state.

– To confirm that the UE continues to monitor the neighbouring cells listed "intra-frequency cell info" IE in the System Information Block type 11 or 12 messages, if no intra-frequency measurements applicable to CELL_DCH are stored.

– To confirm that the UE transmits MEASUREMENT REPORT messages if reporting criteria stated in IE "intra-frequency measurement reporting criteria" in System Information Block type 11 or 12 messages are fulfilled.

– To confirm that a MEASUREMENT CONTROL message received in CELL_DCH state overrides the measurement and associated reporting contexts maintained in the UE by virtue of System Information Block type 11 or 12 messages only if the measurement identities defined within the MEASUREMENT CONTROL message and System Information Block type 11 or 12 are identical.

– To confirm that the UE delete all measurements of type intra-frequency upon cell reselection while in CELL_FACH.

8.4.1.7a.4 Method of test

Initial Condition

System Simulator: 3 cells – Cell 1, cell 2 and cell 3 are active.

SYSTEM INFORMATION BLOCK TYPE 1 (see specific message contents).

UE: PS-DCCH+DTCH_FACH (state 6-11).

Test Procedure

Table 8.4.1.7a-1 illustrates the downlink power to be applied for the 3 cells at various time instants of the test execution. Column marked "T0" denotes the initial conditions, while columns marked "T1" are to be applied subsequently. The exact instants on which these values shall be applied are described in the text in this clause.

Table 8.4.1.7a-1

Parameter

Unit

Cell 1

Cell 2

Cell 3

T0

T1

T2

T3

T4

T5

T6

T0

T1

T2

T3

T4

T5

T6

T0

T1

T2

T3

T4

T5

T6

UTRA RF Channel Number

Mid Range Test Frequency

Mid Range Test Frequency

PCCPCH Ec

dBm/1.28 MHz

-60

-70

-60

-70

-60

-73

-78

-70

-60

-70

-60

-70

-60

-73

-75

-75

-75

-75

-75

-78

-60

The UE is brought to CELL_FACH state in cell 1. (step 1) SS sends SYSTEM INFORMATION CHANGE INDICATION message to UE to inform UE of the modification in the system information.

SS sends a RADIO BEARER RECONFIGURATION message to UE (step2), and configures dedicated physical channels on both uplink and downlink directions. The UE shall move to CELL_DCH state and then return RADIO BEARER RECONFIGURATION COMPLETE message (step3). SS reconfigures the downlink transmission power settings for cells 1 to 3 according to column "T1" in table 8.4.1.7a .The UE shall send a MEASUREMENT REPORT message containing IE “Measured results” to report cell 2’s PCCPCH RSCP value and IE “event results” to report triggering of event type “1g” (step 4). After receiving the MEASUREMENT REPORT message, SS transmits a MEASUREMENT CONTROL message with cell 3 included in the IE “new intra-frequency cell info” (step 5). After receiving such a message, the UE shall transmit another set of MEASUREMENT REPORT message for measurement identity = 11. SS verifies that measurement readings for cell 1,2,3 ‘s PCCPCHCH RSCP are reported in IE “cell measured results” in this message (step 6). SS modifies the downlink transmission power of the respect cells according to the settings in columns “T2” in table 8.4.1.7a-1. The UE shall send a MEASUREMENT REPORT message containing IE “Measured results” to report cell 1’s PCCPCH RSCP value and IE “event results” to report triggering of event type “1g” (step 6b).Next, SS sends a PHYSICAL CHANNEL RECONFIGURATION message (step 7). SS configures common physical channels for both the uplink and the downlink directions. The UE shall transit to CELL_FACH state and then reply with a PHYSICAL CHANNEL RECONFIGURATION COMPLETE message (step 8). SS waits and checks the uplink RACH to confirm that no MEASUREMENT REPORT messages are received (step 9).

SS transmits then a RADIO BEARER RECONFIGURATION message to the UE, to move it to CELL_DCH state (step 9a). The UE shall move to that state, and transmit a RADIO BEARER RECONFIGURATION COMPLETE message to SS (step 9b). SS modifies the downlink transmission power of the respect cells according to the settings in columns “T3” in table 8.4.1.7a-1.Shortly after, a MEASUREMENT REPORT message shall be received which has been triggered by cell 2, i.e. the UE shall have deleted the measurement configured through the MEASUREMENT CONTROL message of step 5, and instead apply the measurement configured in SIB12: a MEASUREMENT REPORT message with measurement identity 10 shall be received while no such message with measurement identity 11 shall be sent by the UE (step 9c). SS modifies the downlink transmission power of the respect cells according to the settings in columns “T4” in table 8.4.1.7a-1. The UE shall send a MEASUREMENT REPORT message containing IE “Measured results” to report cell 1’s PCCPCH RSCP value and IE “event results” to report triggering of event type “1g”.

SS transmits MEASUREMENT CONTROL message on the downlink DCCH, to configure periodic intra-frequency measurements with validity CELL_DCH (step 10). The UE shall send a MEASUREMENT REPORT message (with IE “Measurement identity” = 12) to the SS (step 14).

SS transmits a PHYSICAL CHANNEL RECONFIGURATION message to the UE to move it to CELL_FACH state (step 14a). The UE shall move to that state and transmit a PHYSICAL CHANNEL RECONFIGURATION COMPLETE message to SS (step 14b). SS shall wait and check that no MEASUREMENT REPORT messages are detected on the uplink DCCH (step 14c).

SS transmits a RADIO BEARER RECONFIGURATION message to the UE, to move it to CELL_DCH state (step 14d). The UE shall move to that state, and transmit a RADIO BEARER RECONFIGURATION COMPLETE message to SS (step 14e). Shortly after, a MEASUREMENT REPORT message shall be received, i.e. the UE shall have retrieved the measurement configured through the MEASUREMENT CONTROL message of step 10, instead of the ones that are broadcast in SIB12 (step 14f).

Following the reception of the MEASUREMENT REPORT message, SS commands the UE using MEASUREMENT CONTROL message to release measurement control information stored in “measurement identity” = 12 (step 15). Thereafter, SS verifies that no MEASUREMENT REPORT messages are detected on the uplink DCCH (step 16). After this requirement is satisfied, SS sends MEASUREMENT CONTROL on the downlink DCCH once more (step 17). This message is identical to the one sent in step 10 (see specific message content). A periodical MEASUREMENT REPORT message shall be received from the UE (step 17a).

SS transmits a PHYSICAL CHANNEL RECONFIGURATION message on the downlink DCCH and configures common physical channel (step 18). The UE shall transit to CELL_FACH state and then respond with a PHYSICAL CHANNEL RECONFIGURATION COMPLETE message (step 19). SS monitors the uplink DCCH once more to verify that no MEASUREMENT REPORT messages are detected (step 20). System information block type 11 and System Information Block type 12 for cell 2 shall be different from the default settings according to what is defined in the specific message content part of this section (step 21). SS modifies the downlink transmission power of the respect cells according to the settings in columns “T5” in table 8.4.1.7a-1. The UE shall initiate a cell re-selection procedure. This is verified in the SS when a CELL UPDATE message is received on the uplink CCCH with the “cell update cause” IE set to “cell reselection” (step 22). SS transmits a CELL UPDATE CONFIRM message, which includes “New C-RNTI”, on the DCCH (step 23). Then the UE shall reply with UTRAN MOBILITY INFORMATION CONFIRM message (step 23a). Next, SS sends a RADIO BEARER RECONFIGURATION message on the downlink DCCH, assigning dedicated physical channels in both uplink and downlink directions (step 24). The UE shall respond with a RADIO BEARER RECONFIGURATION COMPLETE message and then return to CELL_DCH state (step 25). SS modifies the downlink transmission power of all cells according to the settings in columns “T6” in table 8.4.1.7a-1. UE shall then send MEASUREMENT REPORT messages reporting cell 3’s PCCPCH RSCP according to the content in System Information Block type 12 messages broadcasted in cell 2 (step 21).SS transmits a MEASUREMENT CONTROL message (step 27) whereby the measurement identity is set to the same value as that in the SIB type 12 messages (step 21). UE shall send MEASUREMENT REPORT message (step 28) reporting cell 1,2,3’s PCCPCH RSCP according to the MEASUREMENT CONTROL message (step 27).

NOTE: If the UE fails the test because of a failure to reselect to a right cell, then the operator may re-run the test.

Expected Sequence

Step

Direction

Message

Comment

UE

SS

1

System Information Block type 11 and 12

UE is initially in PS-DCCH+DTCH_FACH (state 6-11) in cell 1. System Information Block type 11 and 12 messages are changed with respect to the default contents according to the descriptions in “Specific Message Contents” clause.

1a

SYSTEM INFORMATION CHANGE INDICATION

2

RADIO BEARER RECONFIGURATION

SS configures dedicated physical channels.

3

RADIO BEARER RECONFIGURATION COMPLETE

UE shall move to CELL_DCH state.

3a

SS reconfigures the downlink transmission power settings for cells 1 to 3 according to column "T1" in table 8.4.1.7a

4

MEASUREMENT REPORT

Reports cell 2’s PCCPCH RSCP measurement value, with “measurement identity” IE set to “10”.

5

MEASUREMENT CONTROL

A periodic measurement is setup with measurement identity of 11. Cell 3 is added to the list of monitored set of the UE.

6

MEASUREMENT REPORT

SS shall receive a MEASUREMENT REPORT message after the period set in step 5 in which the report for cell 1,cell 2 and cell 3 are included.

6a

SS reconfigures the downlink transmission power settings for cells 1 to 3 according to column "T2" in table 8.4.1.7a

6b

MEASUREMENT REPORT

Cell 1 shall trigger the event 1g and a MEASUREMENT REPORT message shall be sent to SS with the measurement identity 10.

7

PHYSICAL CHANNEL RECONFIGURATION

SS configures PRACH and S-CCPCH physical channels.

8

PHYSICAL CHANNEL RECONFIGURATION COMPLETE

UE shall move to CELL_FACH state.

9

SS waits and checks that no MEASUREMENT REPORT messages are sent by UE.

9a

RADIO BEARER RECONFIGURATION

SS configures dedicated physical channels.

9b

RADIO BEARER RECONFIGURATION COMPLETE

UE shall move to CELL_DCH state.

9b1

SS reconfigures the downlink transmission power settings for cells 1 to 3 according to column "T3" in table 8.4.1.7a

9c

MEASUREMENT REPORT

Cell 2 shall trigger the event 1g and a MEASUREMENT REPORT message shall be sent to SS with the measurement identity 10.

9d

SS reconfigures the downlink transmission power settings for cells 1 to 3 according to column "T4" in table 8.4.1.7a

9e

MEASUREMENT REPORT

Cell 1 shall trigger the event 1g and a MEASUREMENT REPORT message shall be sent to SS with the measurement identity 10.

10

MEASUREMENT CONTROL

SS instructs the UE to setup intra-frequency measurement with measurement identity of 12. Measurement validity" IE is set to CELL_DCH state.

11

Void

12

Void

13

Void

14

MEASUREMENT REPORT

UE reports cell 1 and cell 2’s measured results for PCCPCH RSCP, with “measurement identity” IE set to “12”.

14a

PHYSICAL CHANNEL RECONFIGURATION

SS configures PRACH and S-CCPCH physical channels.

14b

PHYSICAL CHANNEL RECONFIGURATION COMPLETE

UE shall move to CELL_FACH state.

14c

SS waits and check that no MEASUREMENT REPORT messages are sent by the UE.

14d

RADIO BEARER RECONFIGURATION

SS configures dedicated physical channels.

14e

RADIO BEARER RECONFIGURATION COMPLETE

UE shall move to CELL_DCH state.

14f

MEASUREMENT REPORT

UE shall have retrieved and resumed the measurement set up through the MEASUREMENT CONTROL of step 10.The “measurement identity” IE shall be set to “12”.

15

MEASUREMENT CONTROL

Terminate all the intra-frequency measurement and reporting activities related to "measurement identity" = 12.

16

SS waits and verifies that UE stop transmitting MEASUREMENT REPORT messages.

17

MEASUREMENT CONTROL

This message is the same as in step 10.

17a

MEASUREMENT REPORT

UE shall transmit a MEASUREMENT REPORT message with “measurement identity” IE set to “12”.

18

PHYSICAL CHANNEL RECONFIGURATION

Allocates common physical channels.

19

PHYSICAL CHANNEL RECONFIGURATION COMPLETE

UE shall move to CELL_FACH state.

20

SS checks that no MEASUREMENT REPORT messages are received.

21

System Information Block type 11

System Information Block type 12

SS sends SIB11 and SIB12 with specific values to Cell2.

SS reconfigures the downlink transmission power settings for cells 1 to 3 according to column "T5" in table 8.4.1.7a.

22

CELL UPDATE

UE shall re-selects to cell 2 and then perform a cell update procedure.

23

CELL UPDATE CONFIRM

UE shall stay in CELL_FACH state.

23a

UTRAN MOBILITY INFORMATION CONFIRM

24

RADIO BEARER RECONFIGURATION

Dedicated physical channels are assigned to the UE in this message.

25

RADIO BEARER RECONFIGURATION COMPLETE

UE shall return to CELL_DCH state. UE shall not send Measurement Report message with “measurement identity” = ‘12’.

25a

SS reconfigures the downlink transmission power settings of all cells according to column “T6” in table 8.4.1.7a-1.

26

MEASUREMENT REPORT

UE begins to report cell 3’s measured results for PCCPCH RSCP, with “measurement identity” IE set to “1”,event is 1g.

27

MEASUREMENT CONTROL

SS instructs the UE to setup period intra-frequency measurement. “measurement identity” IE set to “1”

28

MEASUREMENT REPORT

UE shall transmit a period MEASUREMENT REPORT message, with “measurement identity” IE set to “1”.

Specific Message Content

System Information Block type 1 (TDD)

Use the default system information block with the same type specified in clause 6.1 of TS 34.108, with the following exceptions:

Information Element

Value/remark

– UE Timers and constants in connected mode

– T312

2

Master Information Block (Step 1)

Information Element

Value/Remarks

MIB Value Tag

A valid MIB value tag as defined in TS 25.331 that is different from the previous value

System Information Block type 11 for cell 1 (Step 1)

All messages content below shall use the same content as described in default message content specified in clause 6.1 of TS 34.108, with the following exception:

Information Element

Value/remark

SIB12 indicator

TRUE

FACH measurement occasion info

Not Present

Measurement control system information

– Use of HCS

Not used

– Cell selection and reselection quality measure

PCCPCH RSCP

– Intra-frequency measurement system information

– Intra-frequency measurement identity

Not present

– Intra-frequency cell info list

– CHOICE intra-frequency cell removal

Not present

– New intra-frequency cells

– Intra-frequency cell id

1

– Cell info

– Cell individual offset

Not present

– Reference time difference to cell

Not present

– Read SFN indicator

FALSE

– CHOICE mode

TDD

– Primary CCPCH info

– TSTD indicator

FALSE

– Cell parameters Id

Refer to clause titled "Default settings for cell No.1 (TDD)" in clause 6.1.4 of TS34.108

– SCTD indicator

FALSE

– Primary CCPCH Tx power

Not present

– timeslot info list

Not present

– Cell Selection and Re-selection info

Not present

– Cells for measurement

Not present

– Intra-frequency measurement quantity

Not present

– Intra-frequency reporting quantity for RACH reporting

Not present

– Maximum number of reported cells on RACH

Not present

– Reporting information for state CELL_DCH

Not present

System Information Block type 12 for cell 1 (Step 1)

Information Element

Value/remark

FACH measurement occasion info

Not Present

Measurement control system information

– Use of HCS

Not used

– Cell selection and reselection quality measure

PCCPCH RSCP

– Intra-frequency measurement system information

– Intra-frequency measurement identity

10

– Intra-frequency cell info list

– CHOICE intra-frequency cell removal

Not present

– New intra-frequency cells

– Intra-frequency cell id

2

– Cell info

– Cell individual offset

Not present

– Reference time difference to cell

Not present

– Read SFN Indicator

FALSE

– CHOICE mode

TDD

– Primary CCPCH Info

– TSTD indicator

FALSE

– Cell parameters Id

Refer to clause titled "Default settings for cell No.2 (TDD)" in clause 6.1.4 of TS34.108

– SCTD indicator

FALSE

– Primary CCPCH Tx power

Not present

– timeslot info list

Not present

– Cell selection and Re-selection info

Not Present

– Cells for measurement

Not Present

– Intra-frequency measurement quantity

– Filter Coefficient

Not present

– CHOICE mode

TDD

– Measurement quantity

PCCPCH RSCP

– Intra-frequency reporting quantity for RACH reporting

Not present

– Maximum number of reported cells on RACH

No report

– Reporting information for state CELL_DCH

– Intra-frequency reporting quantity

– Reporting quantities for active set cells

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CHOICE mode

TDD

– Timeslot ISCP reporting indicator

FALSE

– Proposed TGSN Reporting required

FALSE

– PCCPCH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting quantities for monitored set cells

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CHOICE mode

TDD

– Timeslot ISCP reporting indicator

FALSE

– Proposed TGSN Reporting required

FALSE

– PCCPCH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting quantities for detected cells

Not present

– Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged mode RLC

– Periodic Reporting/Event Trigger Reporting Mode

Event trigger

– CHOICE report criteria

Intra-frequency measurement reporting criteria

– Parameter required for each event

– Intra-frequency event identity

1g

– Reporting range constant

Not present

– W

Not present

– Hysteresis

2 (1 dB)

– Time to trigger

0

– Amount of reporting

Not Present

– Reporting Interval

Not Present

– Reporting cell status

– CHOICE reported cells

Report cells within active and monitored set cells on used frequency

– Maximum number of reported cells

3

– Inter-frequency measurement system information

Not Present

– Inter-RAT measurement system information

Not Present

– Traffic volume measurement system information

Not Present

SYSTEM INFORMATION CHANGE INDICATION (Step 1a)

Information Element

Value/Remarks

BCCH modification info

– MIB Value Tag

A valid MIB value tag as defined in TS 25.331 that is different from the previous value

– BCCH modification time

Not Present

RADIO BEARER RECONFIGURATION (Step 2, Step 9a, Step 14d and Step 24)

Use the same message type found in Annex A, with condition set to A4.

MEASUREMENT REPORT (Steps 4 and 9c)

Information Element

Value/remark

Measurement identity

Check to see if set to 10

Measured Results

– CHOICE measurement

Check to see if set to "Intra-frequency measured results list"

– Intra-frequency measurement results

– Cell measured results

– Cell Identity

Check to see if this IE is absent

– Cell synchronisation information

Check to see if this IE is absent

– CHOICE mode

TDD

– cell parameters identity

Check to see if it’s the same code for cell 1

– proposed TGSN

Check to see if this IE is absent

– PCCPCH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

– timeslotISCP_List

Check to see if this IE is absent

– Cell measured results

– Cell Identity

Check to see if this IE is absent

– Cell synchronisation information

Check to see if this IE is absent

– CHOICE mode

TDD

– cell parameters identity

Check to see if it’s the same code for cell 2

– proposed TGSN

Check to see if this IE is absent

– PCCPCH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

– timeslotISCP_List

Check to see if this IE is absent

Measured Results on RACH

Check to see if this IE is absent

Additional measured results

Check to see if this IE is absent

Event Results

– CHOICE event result

Check to see if it’s set to ‘Intra-frequency measurement event results’

– Intra-frequency event identity

Check to see if this IE is set to ‘1g’

– Cell measurement event results

– Cell parameters Id

Check to see if it’s the same code for cell 2

MEASUREMENT CONTROL (Step 5).

Information Element

Value/remark

Measurement Identity

11

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Periodical Reporting

Additional measurements list

Not Present

CHOICE measurement type

Intra-frequency measurement

– Intra-frequency cell info list

– CHOICE intra-frequency cell removal

Remove no intra-frequency cells

– New intra-frequency info list

– Intra-frequency cell id

3

– Cell info

– Cell individual offset

0 dB

– Reference time difference to cell

Not Present

– Read SFN Indicator

FALSE

– CHOICE mode

TDD

– Primary CCPCH Info

– TSTD indicator

FALSE

– Cell parameters Id

Refer to clause titled "Default settings for cell No.2 (TDD)" in clause 6.1.4 of TS34.108

– SCTD indicator

FALSE

– Primary CCPCH Tx power

Not present

– timeslot info list

Not present

– Cells selection and Re-selection info

Not Present

– Cells for measurement

Not Present

– Intra-frequency measurement quantity

– Filter Coefficient

Not Present

– Measurement quantity

PCCPCH RSCP

– Intra-frequency reporting quantity

– Reporting quantities for active set cells

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CHOICE mode

TDD

– Timeslot ISCP reporting indicator

FALSE

– Proposed TGSN Reporting required

FALSE

– PCCPCH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting quantities for monitored set cells

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CHOICE mode

TDD

– Timeslot ISCP reporting indicator

FALSE

– Proposed TGSN Reporting required

FALSE

– PCCPCH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting quantities for detected cells

Not present

– Reporting cell status

Not present

– Measurement validity

Not present

– CHOICE report criteria

Periodical reporting criteria

– reporting amount

infinity

– reportingInterval

64s

DPCH compressed mode status info

Not Present

MEASUREMENT REPORT (Steps 6)

Information Element

Value/remark

Measurement identity

Check to see if set to 11

Measured Results

– CHOICE measurement

Check to see if set to "Intra-frequency measured results list"

– Intra-frequency measurement results

– Cell measured results

– Cell Identity

Check to see if this IE is absent

– Cell synchronisation information

Check to see if this IE is absent

– CHOICE mode

TDD

– cell parameters identity

Check to see if it’s the same code for cell 2

– proposed TGSN

Check to see if this IE is absent

– PCCPCH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

– timeslotISCP_List

Check to see if this IE is absent

– Cell measured results

– Cell Identity

Check to see if this IE is absent

– Cell synchronisation information

Check to see if this IE is absent

– CHOICE mode

TDD

– cell parameters identity

Check to see if it’s the same code for cell 1

– proposed TGSN

Check to see if this IE is absent

– PCCPCH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

– timeslotISCP_List

Check to see if this IE is absent

– Cell measured results

– Cell Identity

Check to see if this IE is absent

– Cell synchronisation information

Check to see if this IE is absent

– CHOICE mode

TDD

– cell parameters identity

Check to see if it’s the same code for cell 3

– proposed TGSN

Check to see if this IE is absent

– PCCPCH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

– timeslotISCP_List

Check to see if this IE is absent

Measured Results on RACH

Check to see if this IE is absent

Additional measured results

Check to see if this IE is absent

Event Results

Check to see if this IE is absent

MEASUREMENT REPORT (Steps 6b)

Information Element

Value/remark

Measurement identity

Check to see if set to 10

Measured Results

– CHOICE measurement

Check to see if set to "Intra-frequency measured results list"

– Intra-frequency measurement results

– Cell measured results

– Cell Identity

Check to see if this IE is absent

– Cell synchronisation information

Check to see if this IE is absent

– CHOICE mode

TDD

– cell parameters identity

Check to see if it’s the same code for cell 1

– proposed TGSN

Check to see if this IE is absent

– PCCPCH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

– timeslotISCP_List

Check to see if this IE is absent

– Cell measured results

– Cell Identity

Check to see if this IE is absent

– Cell synchronisation information

Check to see if this IE is absent

– CHOICE mode

TDD

– cell parameters identity

Check to see if it’s the same code for cell 2

– proposed TGSN

Check to see if this IE is absent

– PCCPCH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

– timeslotISCP_List

Check to see if this IE is absent

– Cell measured results

– Cell Identity

Check to see if this IE is absent

– Cell synchronisation information

Check to see if this IE is absent

– CHOICE mode

TDD

– cell parameters identity

Check to see if it’s the same code for cell 3

– proposed TGSN

Check to see if this IE is absent

– PCCPCH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

Measured Results on RACH

Check to see if this IE is absent

Additional measured results

Check to see if this IE is absent

Event Results

– CHOICE event result

Check to see if it’s set to ‘Intra-frequency measurement event results’

– Intra-frequency event identity

Check to see if this IE is set to ‘1g’

– Cell measurement event results

– Cell parameters Id

Check to see if it’s the same code for cell 1

PHYSICAL CHANNEL RECONFIGURATION (Steps 7, 14a and 18)

Use the same message sub-type found in clause 9 of TS 34.108, which is entitled "Packet to CELL_FACH from CELL_DCH in PS".

MEASUREMENT REPORT (Steps 9e)

Information Element

Value/remark

Measurement identity

Check to see if set to 10

Measured Results

– CHOICE measurement

Check to see if set to "Intra-frequency measured results list"

– Intra-frequency measurement results

– Cell measured results

– Cell Identity

Check to see if this IE is absent

– Cell synchronisation information

Check to see if this IE is absent

– CHOICE mode

TDD

– cell parameters identity

Check to see if it’s the same code for cell 1

– proposed TGSN

Check to see if this IE is absent

– PCCPCH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

– timeslotISCP_List

Check to see if this IE is absent

– Cell measured results

– Cell Identity

Check to see if this IE is absent

– Cell synchronisation information

Check to see if this IE is absent

– CHOICE mode

TDD

– cell parameters identity

Check to see if it’s the same code for cell 2

– proposed TGSN

Check to see if this IE is absent

– PCCPCH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

– timeslotISCP_List

Check to see if this IE is absent

Measured Results on RACH

Check to see if this IE is absent

Additional measured results

Check to see if this IE is absent

Event Results

– CHOICE event result

Check to see if it’s set to ‘Intra-frequency measurement event results’

– Intra-frequency event identity

Check to see if this IE is set to ‘1g’

– Cell measurement event results

– Cell parameters Id

Check to see if it’s the same code for cell 1

MEASUREMENT CONTROL (Step 10 and 17).

Information Element

Value/remark

Measurement Identity

12

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Periodical Reporting

Additional measurements list

Not Present

CHOICE measurement type

Intra-frequency measurement

– Intra-frequency cell info list

– CHOICE intra-frequency cell removal

Remove no intra-frequency cells

– New intra-frequency info list

Not Present

– Cells for measurement

Not Present

– Intra-frequency measurement quantity

– Filter Coefficient

Not Present

– Measurement quantity

PCCPCH RSCP

– Intra-frequency reporting quantity

– Reporting quantities for active set cells

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CHOICE mode

TDD

– Timeslot ISCP reporting indicator

FALSE

– Proposed TGSN Reporting required

FALSE

– PCCPCH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting quantities for monitored set cells

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CHOICE mode

TDD

– Timeslot ISCP reporting indicator

FALSE

– Proposed TGSN Reporting required

FALSE

– PCCPCH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting quantities for detected cells

Not present

– Reporting cell status

Not present

– Measurement validity

CELL DCH

– CHOICE report criteria

Periodical reporting criteria

– reporting amount

infinity

– reportingInterval

64s

DPCH compressed mode status info

Not Present

MEASUREMENT REPORT (Steps 14, 14f and 17a)

Information Element

Value/remark

Measurement identity

Check to see if set to 12

Measured Results

– CHOICE measurement

Check to see if set to "Intra-frequency measured results list"

– Intra-frequency measurement results

– Cell measured results

– Cell Identity

Check to see if this IE is absent

– Cell synchronisation information

Check to see if this IE is absent

– CHOICE mode

TDD

– cell parameters identity

Check to see if it’s the same code for cell 1

– proposed TGSN

Check to see if this IE is absent

– PCCPCH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

– timeslotISCP_List

Check to see if this IE is absent

– Cell measured results

– Cell Identity

Check to see if this IE is absent

– Cell synchronisation information

Check to see if this IE is absent

– CHOICE mode

TDD

– cell parameters identity

Check to see if it’s the same code for cell 2

– proposed TGSN

Check to see if this IE is absent

– PCCPCH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

– timeslotISCP_List

Check to see if this IE is absent

Measured Results on RACH

Check to see if this IE is absent

Additional measured results

Check to see if this IE is absent

Event Results

Check to see if this IE is absent

MEASUREMENT CONTROL (Step 15)

Information Element

Value/remark

Measurement Identity

12

Measurement Command

Release

Measurement Reporting Mode

Not Present

Additional measurements list

Not Present

CHOICE Measurement type

Not Present

DPCH compressed mode status info

Not Present

System Information Block type 11 for cell 2 (Step 21)

All messages content below shall use the same content as described in default message content specified in clause 6.1 of TS 34.108, with the following exception:

Information Element

Value/Remark

SIB12 indicator

TRUE

FACH measurement occasion info

Not Present

Measurement control system information

– Use of HCS

Not used

– Cell selection and reselection quality measure

PCCPCH RSCP

– Intra-frequency measurement system information

– Intra-frequency measurement identity

Not present

– Intra-frequency cell info list

– CHOICE intra-frequency cell removal

Not Present

– New intra-frequency cells

– Intra-frequency cell id

2

– Cell info

– Cell individual offset

Not Present

– Reference time difference to cell

Not present

– Read SFN indicator

FALSE

– CHOICE mode

TDD

– Primary CCPCH info

– TSTD indicator

FALSE

– Cell parameters Id

Refer to clause titled "Default settings for cell No.1 (TDD)" in clause 6.1.4 of TS34.108

– SCTD indicator

FALSE

– Primary CCPCH Tx power

Not present

– timeslot info list

Not present

– Cell Selection and Re-selection info

Not present

– Intra-frequency cell id

1

– Cell info

– Cell individual offset

Not Present

– Reference time difference to cell

Not present

– Read SFN indicator

TRUE

– CHOICE mode

TDD

– Primary CCPCH info

– TSTD indicator

FALSE

– Cell parameters Id

Refer to clause titled "Default settings for cell No.1 (TDD)" in clause 6.1.4 of TS34.108

– SCTD indicator

FALSE

– Primary CCPCH Tx power

Not present

– timeslot info list

Not present

– Cell Selection and Re-selection info

Not present

– Intra-frequency cell id

3

– Cell info

– Cell individual offset

Not Present

– Reference time difference to cell

Not present

– Read SFN indicator

TRUE

– CHOICE mode

TDD

– Primary CCPCH info

– TSTD indicator

FALSE

– Cell parameters Id

Refer to clause titled "Default settings for cell No.1 (TDD)" in clause 6.1.4 of TS34.108

– SCTD indicator

FALSE

– Primary CCPCH Tx power

Not present

– timeslot info list

Not present

– Cell Selection and Re-selection info

Not present

– Cells for measurement

Not present

– Intra-frequency measurement quantity

– Filter coefficient

Not Present

– CHOICE mode

TDD

– Measurement quantity

PCCPCH RSCP

– Intra-frequency reporting quantity for RACH reporting

Not present

– Maximum number of reported cells on RACH

Not present

– Reporting information for state CELL_DCH

Not present

System Information Block type 12 for cell 2 (Step 21)

Information Element

Value/Remark

FACH measurement occasion info

Not Present

Measurement control system information

– Use of HCS

Not used

– Cell selection and reselection quality measure

PCCPCH RSCP

– Intra-frequency measurement system information

– Intra-frequency measurement identity

Not present

– Intra-frequency cell info list

Not Present

– Intra-frequency measurement quantity

– Filter coefficient

Not Present

– CHOICE mode

TDD

– Measurement quantity

PCCPCH RSCP

– Intra-frequency reporting quantity for RACH reporting

Not present

– Maximum number of reported cells on RACH

Not present

– Reporting information for state CELL_DCH

– Intra-frequency reporting quantity

– Reporting quantities for active set cells

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CHOICE mode

TDD

– Timeslot ISCP reporting indicator

FALSE

– Proposed TGSN Reporting required

FALSE

– PCCPCH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting quantities for monitored set cells

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CHOICE mode

TDD

– Timeslot ISCP reporting indicator

FALSE

– Proposed TGSN Reporting required

FALSE

– PCCPCH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting quantities for detected set cells

Not Present

– Measurement reporting mode

– Measurement Report Transfer Mode

Acknowledged mode RLC

– Periodic Reporting/Event Trigger Reporting Mode

Event trigger

– CHOICE report criteria

Intra-frequency measurement reporting criteria

– Intra-frequency measurement reporting criteria

– Intra-frequency event identity

1g

– W

0

– Hysteresis

2 (1dB)

– Threshold Used Frequency

Not Present

– Reporting deactivation threshold

2

– Replacement activation threshold

Not Present

– Time to trigger

0

– Amount of reporting

Not Present

– Reporting interval

Not Present

– Reporting cell status

– CHOICE reported cell

Report cell within active set and/or monitored set cells on used frequency

– Maximum number of reported cells

3

– Inter-frequency measurement system information

Not present

– Inter-RAT measurement system information

Not present

– Traffic volume measurement system information

Not Present

– UE internal measurement system information

Not Present

CELL UPDATE (Step 22)

Information Element

Value/remark

U-RNTI

– SRNC Identity

Check to see if set to ‘0000 0000 0001’

– S-RNTI

Check to see if set to ‘0000 0000 0000 0000 0001’

START List

Check to see if it is present

AM_RLC error indication(RB2, RB3 or RB4)

Checked to see if it is set to FALSE

AM_RLC error indication(RB>4)

Checked to see if it is set to FALSE

Cell Update Cause

Check to see if set to ‘Cell Re-selection’

RB timer indicator

– T314 expired

Checked to see if it is set to ‘FALSE’

– T315 expired

Checked to see if it is set to ‘FALSE’

Measured results on RACH

Check to see if it is absent

CELL UPDATE CONFIRM (Step 23)

Use the default message content of the same message type in Annex A, with the following exceptions.

Information Element

Value/Remarks

New C-RNTI

‘1010 1010 1010 1010’

UTRAN MOBILITY INFORMATION CONFIRM (Step 23a)

Only the message type is checked.

MEASUREMENT REPORT (Step 26)

Information Element

Value/Remarks

Measurement identity

Check to see if set to 1

Measured Results

– CHOICE measurement

Check to see if set to "Intra-frequency measured results list"

– Intra-frequency measurement results

– Cell measured results

– Cell Identity

Check to see if this IE is absent

– Cell synchronisation information

Check to see if this IE is absent

– CHOICE mode

TDD

– cell parameters identity

Check to see if it’s the same code for cell 3

– proposed TGSN

Check to see if this IE is absent

– PCCPCH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

– timeslotISCP_List

Check to see if this IE is absent

– Cell Identity

Check to see if this IE is absent

– Cell synchronisation information

Check to see if this IE is present

– CHOICE mode

TDD

– cell parameters identity

Check to see if it’s the same code for cell 2

– proposed TGSN

Check to see if this IE is absent

– PCCPCH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

– timeslotISCP_List

– Cell Identity

Check to see if this IE is absent

– Cell synchronisation information

Check to see if this IE is present

– CHOICE mode

TDD

– cell parameters identity

Check to see if it’s the same code for cell 1

– proposed TGSN

Check to see if this IE is absent

– PCCPCH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

– timeslotISCP_List

Measured Results on RACH

Check to see if this IE is absent

Additional measured results

Check to see if this IE is absent

Event Results

– CHOICE event result

Check to see if it’s set to ‘Intra-frequency measurement event results’

– Intra-frequency event identity

Check to see if this IE is set to ‘1g’

– Cell measurement event results

– CHOICE mode

TDD

– Cell parameters Id

Check to see if it’s the same code for cell 3

NOTE: Cells 2 and 3 can be received in any order

MEASUREMENT CONTROL (Step 27)

Information Element

Value/remark

Measurement Identity

1

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Period

Additional measurements list

Not Present

CHOICE measurement type

Intra-frequency measurement

– Intra-frequency cell info list

– CHOICE intra-frequency cell removal

Remove no intra-frequency cells

– New intra-frequency info list

Not Present

– Cells for measurement

Not Present

– Intra-frequency measurement quantity

– Filter Coefficient

Not Present

– Measurement quantity

PCCPCH RSCP

– Intra-frequency reporting quantity

– Reporting quantities for active set cells

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CHOICE mode

TDD

– Timeslot ISCP reporting indicator

FALSE

– Proposed TGSN Reporting required

FALSE

– PCCPCH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting quantities for monitored set cells

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CHOICE mode

TDD

– Timeslot ISCP reporting indicator

FALSE

– Proposed TGSN Reporting required

FALSE

– PCCPCH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting quantities for detected cells

Not present

– Reporting cell status

Not present

– Measurement validity

Not present

– CHOICE report criteria

period measurement criteria

– reporting amount

infinity

– reportingInterval

64s

DPCH compressed mode status info

Not Present

MEASUREMENT REPORT (Step 28)

Information Element

Value/Remarks

Measurement identity

Check to see if set to 1

Measured Results

– CHOICE measurement

Check to see if set to "Intra-frequency measured results list"

– Intra-frequency measurement results

– Cell measured results

– Cell Identity

Check to see if this IE is absent

– Cell synchronisation information

Check to see if this IE is absent

– CHOICE mode

TDD

– cell parameters identity

Check to see if it’s the same code for cell 3

– proposed TGSN

Check to see if this IE is absent

– PCCPCH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

– timeslotISCP_List

Check to see if this IE is absent

– Cell Identity

Check to see if this IE is absent

– Cell synchronisation information

Check to see if this IE is present

– CHOICE mode

TDD

– cell parameters identity

Check to see if it’s the same code for cell 2

– proposed TGSN

Check to see if this IE is absent

– PCCPCH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

– timeslotISCP_List

– Cell Identity

Check to see if this IE is absent

– Cell synchronisation information

Check to see if this IE is present

– CHOICE mode

TDD

– cell parameters identity

Check to see if it’s the same code for cell 1

– proposed TGSN

Check to see if this IE is absent

– PCCPCH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

– timeslotISCP_List

Measured Results on RACH

Check to see if this IE is absent

Additional measured results

Check to see if this IE is absent

Event Results

Check to see if this IE is absent

8.4.1.7a.5 Test Requirement

After step 3 the UE shall report cell 2’s PCCPCH RSCP value by transmitting MEASUREMENT REPORT messages.

After step 9 and step 11 the UE shall not transmit MEASUREMENT REPORT messages, which pertain to intra-frequency type measurement reporting.

After step 9b, the UE shall transmit a MEASUREMENT REPORT according to what is broadcast in SIB 11 and 12 of cell 1, and MEASUREMENT REPORT message pertaining to the MEASUREMENT CONTROL message that it had received in step 5.

After steps 13 and 14e, the UE shall resume the measurement and reporting activities as specified in MEASUREMENT CONTROL message received in step 10. The UE shall transmit MEASUREMENT REPORT messages, containing measured results of cell 2’s PCCPCH RSCP value.

After step 15 the UE shall stop measurement activities pertaining to periodic reporting of cell 2’s PCCPCH RSCP, no MEASUREMENT REPORT messages shall be detectable by the SS on the uplink DCCH.

After step 17, the UE shall transmit a MEASUREMENT REPORT message to the SS as specified in the MEASUREMENT CONTROL message received in step 17.

After step 21 the UE shall re-select to cell 2 and initiate a cell update procedure. SS shall receive a CELL UPDATE message on the uplink CCCH of cell 2, with the "cell update cause" IE stated as "cell re-selection".

After step 23, the UE shall transmit UTRAN MOBILITY INFORMATION CONFIRM message on the uplink DCCH AM RLC.

After step 25, UE shall not send MEASUREMENT REPORT message with “measurement identity” = ‘12’.

After step 25a the UE shall report cell 3’s PCCPCH RSCP value by transmitting MEASUREMENT REPORT messages.

After step 27, UE shall send MEASUREMENT REPORT message with “measurement identity” = ‘1’.

8.4.1.8 Measurement Control and Report: Inter-frequency measurement for transition from CELL_FACH to CELL_DCH state (FDD)

8.4.1.8.1 Definition

8.4.1.8.2 Conformance requirement

Upon transition from CELL_FACH to CELL_DCH state, the UE shall:

1> if inter-frequency measurements applicable to CELL_DCH state are stored in the variable MEASUREMENT_IDENTITY:

2> if the cell in which the UE transited from CELL_FACH state is included in the active set for the CELL_DCH state, the UE shall:

3> resume the measurement reporting.

2> otherwise, the UE shall:

3> not resume the measurement reporting. The measurement shall be restarted when a MEASUREMENT CONTROL message is received with the corresponding measurement identity.

If the IE "DPCH compressed mode info" is included, and if the IE group "transmission gap pattern sequence configuration parameters" is included, the UE shall for each transmission gap pattern sequence perform the following consistency checks:

1> if UE, according to its measurement capabilities, and for the measurement purpose indicated by IE "TGMP", requires UL compressed mode for measurements on any of the cells to be measured according to UE variable CELL_INFO_LIST, and CHOICE ‘UL/DL mode’ indicates ‘DL only’:

2> set the variable INVALID_CONFIGURATION to TRUE.

1> if UE, according to its measurement capabilities, and for the measurement purpose indicated by IE "TGMP", requires DL compressed mode for measurements on any of the cells to be measured according to UE variable CELL_INFO_LIST, and CHOICE ‘UL/DL mode’ indicates ‘UL only’:

2> set the variable INVALID_CONFIGURATION to TRUE.

1> if UE already has an active transmission gap pattern sequence that, according to IE "TGMP", has the same measurement purpose, and both patterns will be active after the new configuration has been taken into use:

2> set the variable INVALID_CONFIGURATION to TRUE.

If variable INVALID_CONFIGURATION has value FALSE after UE has performed the checks above, the UE shall:

1> if pattern sequence corresponding to IE "TGPSI" is already active (according to "TGPS Status Flag"):

2> deactivate this pattern sequence at the beginning of the frame, indicated by IE "Activation time" received in this message, when the new configuration received in this message is taken into use.

1> update each pattern sequence to the variable TGPS_IDENTITY according to the IE "TGPSI";

1> update into the variable TGPS_IDENTITY the configuration information defined by IE group" transmission gap pattern sequence configuration parameters ";

1> after the new configuration has been taken into use:

2> activate the stored pattern sequence corresponding to each IE "TGPSI" for which the "TGPS status flag" is set to "activate" at the time indicated by IE "TGCFN"; and

2> begin the inter-frequency corresponding to the pattern sequence measurement purpose of each activated pattern sequence;

2> if the new configuration is taken into use at the same CFN as indicated by IE "TGCFN":

3> start the concerned pattern sequence immediately at that CFN.

1> monitor if the parallel transmission gap pattern sequences create an illegal overlap, and in case of overlap, take actions as specified in TS 25.331 subclause 8.2.11.2.

Reference

3GPP TS 25.331 clause 8.4.1.7.2, 8.6.6.15

8.4.1.8.3 Test Purpose

1. To confirm that the UE resumes inter-frequency measurements and reporting stored for which the measurement control information has IE "measurement validity" assigned to the value "CELL_DCH", after it re-enters CELL_DCH state from CELL_FACH state.

2. To confirm that the UE resumes inter-frequency measurement and reporting activities after it has received a MEASUREMENT CONTROL message specifying that a stored compressed mode pattern sequence be re-activated.

8.4.1.8.4 Method of test

Initial Condition

System Simulator: 2 cells – Cell 1, cell 5 are active.

SYSTEM INFORMATION BLOCK TYPE 1 (see specific message contents).

UE: PS-DCCH+DTCH_DCH (State 6-10) in cell 1 as specified in clause 7.4 of TS 34.108.

Related ICS/IXIT statements

– Compressed mode required yes/no

Table 8.4.1.8-1 illustrates the downlink power to be applied for the 2 cells in this test.

Table 8.4.1.8-1

Para-meter

Unit

Cell 1

Cell 5

UTRA RF Channel Number

Mid Range Test Frequency

High Range Test Frequency

CPICH Ec

dBm/3.84 MHz

-60

-75

The UE is in CELL_DCH state in cell 1 (step 1). SS transmits MEASUREMENT CONTROL message to add cell 5 into the IE "inter-frequency cell info" (step 2). If UE requires compressed mode, SS checks that no MEASUREMENT REPORT messages are detected on the uplink DCCH after it has transmitted the MEASUREMENT CONTROL message. (step 3). SS checks that the UE sends a MEASUREMENT REPORT message on the uplink DCCH only if UE does not require compressed mode.

SS sends a PHYSICAL CHANNEL RECONFIGURATION message on the downlink DCCH to move the UE to CELL_FACH state (step 4). The UE shall reconfigure itself to receive and transmit using the common physical channels assigned, and send PHYSICAL CHANNEL RECONFIGURATION COMPLETE on the uplink DCCH (step 5). SS modifies the content of Master Information Block and System Information Block type 12 messages, including cell 5 in the IE "inter-frequency cell info" (step 6) and providing FACH Measurement Occasion Info. SS transmits SYSTEM INFORMATION CHANGE INDICATION message to UE. Once again, SS verifies that the UE does not transmit MEASUREMENT REPORT messages in the uplink direction (step 7).

SS sends PHYSICAL CHANNEL RECONFIGURATION message, and configures dedicated physical. If UE requires compressed mode, in this message, SS commands the UE to start applying compressed mode mechanism for DPCH. The UE shall move to CELL_DCH state and then reply with PHYSICAL CHANNEL RECONFIGURATION COMPLETE message (step 9). The UE shall transmit 1 MEASUREMENT REPORT message, containing the selected frequency quality estimate (in this case CPICH RSCP) of cell 5. The UE shall also report the triggering of event ‘2c’ in the IE "Event results" of MEASUREMENT REPORT message (step 10).

SS transmits a MEASUREMENT CONTROL message on the downlink DCCH using AM-RLC (step 11). The UE shall transmit MEASUREMENT REPORT messages at 2 seconds interval (step 12).

If UE requires compressed mode, SS transmits a PHYSICAL CHANNEL RECONFIGURATION message and deactivates the compressed mode pattern sequence with "TGPSI" IE set to 1 (step 13). The UE shall respond by sending PHYSICAL CHANNEL RECONFIGURATION COMPLETE message and also either stop the periodic reporting activities or continue the periodic measurement reporting without any measured results (step 14).

Following this if UE requires compressed mode, SS sends a MEASUREMENT CONTROL message and re-activates the compressed mode pattern sequence by using the "DPCH compressed mode status info" IE (step 15). SS confirms that the UE has reconfigured itself to start measurement reporting with measured results included again. The SS shall receive MEASUREMENT REPORT messages continuously at 2 seconds interval (step 16). The SS then sends a MEASUREMENT CONTROL ordering the UE to release the measurement corresponding to identity 14, and to stop compressed mode (step 17). At reception of that message, the UE shall stop compressed mode and delete the measurement corresponding to that identity (step 18). The SS then transmits a PHYSICAL CHANNEL RECONFIGURATION message to the UE to order the UE to start compressed mode once again (step 19). The UE answers with a PHYSICAL CHANNEL RECONFIGURATION COMPLETE message, and starts compressed mode (step 20). SS checks then that it does not receive any MEASUREMENT REPORT message from the UE after that point (step 21).

Expected Sequence

Step

Direction

Message

Comment

UE

SS

1

The initial state of UE is in CELL_DCH state of cell 1.

2

MEASUREMENT CONTROL

SS specifies inter-frequency measurement and reporting parameters for cell 5, with "measurement validity" IE present and "UE state" set to "CELL_DCH".

3

MEASUREMENT REPORT

If compressed mode is not required (refer ICS/IXIT), SS checks that UE transmit this message, or else SS checks that no MEASUREMENT REPORT messages are detected on the uplink DCCH.

4

PHYSICAL CHANNEL RECONFIGURATION

SS moves the UE to CELL_FACH state.

5

PHYSICAL CHANNEL RECONFIGURATION COMPLETE

UE shall move to CELL_FACH state.

6

Master Information Block, Scheduling Block 1

System Information Block type 12

SS modifies MIB and SIB 12 including cell 5 in "inter-frequency cell info", and providing FACH Measurement occasion info.

7

SYSTEM INFORMATION CHANGE INDICATION

After SS transmits this message, SS confirms that there are no transmissions of MEASUREMENT REPORT message in the uplink direction.

8

PHYSICAL CHANNEL RECONFIGURATION

See specific message content below.

9

PHYSICAL CHANNEL RECONFIGURATION COMPLETE

10

MEASUREMENT REPORT

UE shall resume inter-frequency measurement task for cell 5 and report the measured CPICH RSCP value for cell 5.

(See Specific Message Contents)

11

MEASUREMENT CONTROL

SS changes the reporting criteria for cell 5 to ‘periodic reporting’

12

MEASUREMENT REPORT

UE shall begin to transmit this message at 2 seconds interval. If compressed mode is not required (refer ICS/IXIT), the test ends here.

13

PHYSICAL CHANNEL RECONFIGURATION

SS deactivates the currently used pattern sequence for compressed mode operation.

14

PHYSICAL CHANNEL RECONFIGURATION COMPLETE

UE stays in CELL_DCH state. SS verifies that either no MEASUREMENT REPORT messages are received, or MEASUREMENT REPORTS are received every 2s with IE “Measured results” not included.

15

MEASUREMENT CONTROL

SS activates the pattern sequence stored by the UE.

16

MEASUREMENT REPORT

SS checks that MEASURE-MENT REPORT messages with IE “Measured results” included are received at 2 seconds interval.

17

MEASUREMENT CONTROL

SS orders the UE to release the measurement with identity 14, and to stop compressed mode.

18

SS waits for 5s to check that UE does not send MEASUREMENT REPORT. This verifies that the UE has stopped compressed mode.

19

PHYSICAL CHANNEL RECONFIGURATION

SS orders the UE to start compressed mode again.

20

PHYSICAL CHANNEL RECONFIGURATION COMPLETE

The UE transmits the response message and starts compressed mode

21

SS wait for 5s to check that the UE does not send any MEASUREMENT REPORT.

Specific Message Content

Unless explicitly stated, the messages below shall be used.

System Information Block type 1 (FDD)

Use the default system information block with the same type specified in clause 6.1 of TS 34.108, with the following exceptions:

Information Element

Value/remark

– UE Timers and constants in connected mode

– T312

2

MEASUREMENT CONTROL (Step 2)

Information Element

Value/remark

Measurement Identity

14

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Event Trigger

Additional measurements list

Not Present

CHOICE measurement type

Inter-frequency measurement

– Inter-frequency cell info list

– CHOICE inter-frequency cell removal

No inter-frequency cells removed

– New inter-frequency info list

– Inter-frequency cell id

5

– Frequency info

– UARFCN uplink (Nu)

Not present

Absence of this IE is equivalent to applying the default duplex distance defined for the operating frequency according to 3GPP TS 25.101 [21]

– UARFCN downlink (Nd)

UARFCN of the downlink frequency for cell 5

– Cell info

– Cell individual offset

0 dB

– Reference time difference to cell

Not Present

– Read SFN Indicator

FALSE

– CHOICE Mode

FDD

– Primary CPICH Info

– Primary Scrambling Code

Set to same code as used for cell 5

– Primary CPICH TX power

Not Present

– TX Diversity Indicator

FALSE

– Cells for measurement

Not Present

– Inter-frequency measurement quantity

– CHOICE reporting criteria

Inter-frequency reporting criteria

– Filter Coefficient

0

– Measurement quantity for frequency quality estimate

CPICH RSCP

– Inter-frequency reporting quantity

– UTRA Carrier RSSI

FALSE

– Frequency quality estimate

FALSE

– Non frequency related cell reporting quantities

– Cell synchronisation information reporting indicator

FALSE

– Cell Identity reporting indicator

TRUE

– CPICH Ec/No reporting indicator

FALSE

– CPICH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting cell status

Not present

– Measurement validity

– UE State

CELL_DCH

– Inter-frequency set update

-UE autonomous update

On with no reporting

– Non autonomous update mode

Not Present

– CHOICE report criteria

Inter-frequency measurement reporting criteria

– Parameters required for each event

– Inter-frequency event identity

2c

– Threshold used frequency

Not Present

– W used frequency

Not Present

– Hysteresis

2 (1 dB)

– Time to trigger

10 ms

– Reporting cell status

– CHOICE reported cell

Report cells within active and/or monitored set on used frequency or within active and/or monitored set on non-used frequency

– Maximum number of reported cells

2

– Parameters required for each non-used frequency

– Threshold non used frequency

-85 dBm

– W non-used frequency

0.0

DPCH compressed mode status info

Not Present

PHYSICAL CHANNEL RECONFIGURATION (Step 4)

Use the same message sub-type found in [9] TS 34.108 clause 9 titled "(Packet to CELL_FACH from CELL_DCH in PS)".

Information Element

Value/Remark

Version

– Downlink information for each radio link

– Choice mode

FDD

– Primary CPICH info

– Primary scrambling code

Scrambling code for cell 1. Ref. to the Default setting in TS34.108 clause 6.1 (FDD)

– PDSCH with SHO DCH info

Not Present

– PDSCH code mapping

Not Present

– Downlink DPCH info for each RL

Not Present

– SCCPCH Information for FACH

Not Present

R99 and Rel-4 only

Master Information Block (Step 6)

Information Element

Value/Remark

MIB Value Tag

A valid MIB value tag as defined in TS 25.331 that is different from the previous value

SB 1 Cell Value tag

Set to (Current SB1 value tag + 1)

Scheduling Block 1 (Step 6)

Information Element

Value/remark

SIB 12 Cell Value tag

Set to (Current SIB 12 value tag + 1)

System Information Block type 12 (Step 6)

Information Element

Value/remark

FACH measurement occasion info

– FACH Measurement occasion cycle length coefficient

3

– Inter-frequency FDD measurement indicator

TRUE

– Inter-frequency TDD measurement indicator

FALSE

– Inter-RAT measurement indicators

Not Present

Measurement control system information

-Use of HCS

Not used

-Cell selection and reselection quality measure

CPICH RSCP

– Intra-frequency measurement system information

Not Present

– Inter-frequency measurement system information

– Inter-frequency cell info list

– CHOICE inter-frequency cells removal

Not Present

– New inter-frequency info list

– Inter-frequency cell id

Set to id of cell 5

– Cell info

– Cell individual offset

Not Present

– Reference time difference to cell

Not Present

– Read SFN Indicator

FALSE

– CHOICE Mode

FDD

– Primary CPICH Info

– Primary Scrambling Code

Refer to clause titled "Default settings for cell No.5 (FDD)" in clause 6.1.4

– Primary CPICH TX power

Not Present

– TX Diversity Indicator

FALSE

– Cell selection and Re-selection info

Not Present – use default values

– Inter-RAT measurement system information

Not Present

– Traffic volume measurement system information

Not Present

PHYSICAL CHANNEL RECONFIGURATION (Step 8)

Use the same message sub-type found in [9] TS 34.108 clause 9 titled ("Packet to CELL_DCH from CELL_FACH in PS")

Information Element

Value/Remark

Version

New U-RNTI

Not Present

New C-RNTI

Not Present

New DSCH-RNTI

Not Present

RRC State indicator

CELL_DCH

UTRAN DRX cycle length coefficient

Not Present

CN information info

Not Present

URA identity

Not Present

Downlink counter synchronisation info

Not Present

Frequency info

Not Present

Maximum allowed UL TX power

Not Present

CHOICE mode

FDD

– Downlink PDSCH information

Not Present

Downlink information common for all radio links

– CHOICE mode

FDD

– DPCH compressed mode info

– TGPSI

1

– TGPS Status Flag

Activate

– TGCFN

(Current CFN+(256 – TTI/10msec)) mod 256

– Transmission gap pattern sequence

configuration parameters

– TGMP

FDD Measurement

– TGPRC

Infinity

– TGSN

4

– TGL1

7

– TGL2

Not Present

– TGD

undefined

– TGPL1

3

– TGPL2

Not Present

R99 and REL-4 only

– RPP

Mode 0

– ITP

Mode 0

– CHOICE UL/DL Mode

UL and DL, UL only or DL only (depending on the UE capability)

– Downlink compressed mode method

SF/2 (or not sent, depending on the UE capability)

– Uplink compressed mode method

SF/2 (or not sent, depending on the UE capability)

– Downlink frame type

B

– DeltaSIR1

20 (2.0)

– DeltaSIRAfter1

10 (1.0)

– DeltaSIR2

Not Present

– DeltaSIRAfter2

Not Present

– N identify abort

Not Present

– T Reconfirm abort

Not Present

– TX Diversity mode

Not Present

– SSDT information

Not Present

R99 and Rel-4 only

– Default DPCH Offset Value

Not Present

MEASUREMENT REPORT (Step 3)

Information Element

Value/remark

Measurement identity

Check to see if set to 14

Measured Results

– CHOICE measurement

Check to see if set to "Inter-frequency measured results list"

– Inter-frequency measurement results

– Frequency info

– UARFCN uplink

The presence of this IE is not checked

– UARFCN downlink

Check that the value of this IE is set to UARFCN for the downlink corresponding to f5

– UTRA carrier RSSI

Check to see if it is absent

– Inter-frequency cell measurement results

– Cell measured results

– Cell Identity

Check to see if it is absent

– Cell synchronisation information

Check to see if it is absent

– Primary CPICH Info

– Primary Scrambling Code

Check to see if set to the same code for cell 5

– CPICH Ec/No

Check to see if it is absent

– CPICH RSCP

Check to see if it is present

– Pathloss

Check to see if it is absent

Measured Results on RACH

Check to see if it is absent

Event Results

– CHOICE event result

Inter-frequency event results

– Inter-frequency event identity

Check to see if it’s set to ‘2c’

– Inter-frequency cells

– Frequency Info

– UARFCN uplink

The presence of this IE is not checked

– UARFCN downlink

Check that the value of this IE is set to UARFCN for the downlink corresponding to f5

– Non frequency related measurement event results

– Primary CPICH Info

– Primary Scrambling Code

Check to see if set to the same code for cell 5

MEASUREMENT CONTROL (Step 11)

Information Element

Value/remark

Measurement Identity

14

Measurement Command

Set up

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Periodical reporting

Additional measurements list

Not Present

CHOICE measurement type

Inter-frequency measurement

– Inter-frequency cell info list

– CHOICE inter-frequency cell removal

No inter-frequency cells removed

– New inter-frequency info list

– Inter-frequency cell id

5

– Frequency info

– UARFCN uplink (Nu)

Not present

Absence of this IE is equivalent to applying the default duplex distance defined for the operating frequency according to 3GPP TS 25.101 [21]

– UARFCN downlink (Nd)

UARFCN of the downlink frequency for cell 5

– Cell info

– Cell individual offset

0 dB

– Reference time difference to cell

Not Present

– Read SFN Indicator

FALSE

– CHOICE Mode

FDD

– Primary CPICH Info

– Primary Scrambling Code

Set to same code as used for cell 5

– Primary CPICH TX power

Not Present

– TX Diversity Indicator

FALSE

– Cells for measurement

– Inter-frequency cell id

5

– Inter-frequency measurement quantity

– CHOICE reporting criteria

Inter-frequency reporting criteria

– Filter Coefficient

0

– Measurement quantity for frequency quality estimate

CPICH RSCP

– Inter-frequency reporting quantity

– UTRA Carrier RSSI

FALSE

– Frequency quality estimate

FALSE

– Non frequency related cell reporting quantities

– Cell synchronisation information reporting indicator

FALSE

– Cell Identity reporting indicator

TRUE

– CPICH Ec/No reporting indicator

FALSE

– CPICH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting cell status

– CHOICE reported cell

Report cells within active and/or monitored set on used frequency or within active and/or monitored set on non-used frequency

– Maximum number of reported cells

2

– Measurement validity

Not Present

– Inter-frequency set update

Not Present

– CHOICE report criteria

Periodic reporting criteria

– Amount of reporting

Infinity

– Reporting interval

2000 milliseconds

DPCH compressed mode status info

Not Present

MEASUREMENT REPORT (Step 12, 16)

Information Element

Value/remark

Measurement identity

Check to see if set to 14

Measured Results

– CHOICE measurement

Check to see if set to "Inter-frequency measured results list"

– Inter-frequency measurement results

– Frequency info

– UARFCN uplink

The presence of this IE is not checked

– UARFCN downlink

Check that the value of this IE is set to UARFCN for the downlink corresponding to f5

– UTRA carrier RSSI

Check to see if it is absent

– Inter-frequency cell measurement results

– Cell measured results

– Cell Identity

Check to see if is absent

– Cell synchronisation information

Check to see if it is absent

– Primary CPICH Info

– Primary Scrambling Code

Check to see if set to the same code for cell 5

– CPICH Ec/No

Check to see if it is absent

– CPICH RSCP

Check to see if it is present

– Pathloss

Check to see if it is absent

– CFN-SFN observed time difference

Check to see if it is absent

Measured Results on RACH

Check to see if it is absent

Event Results

Check to see if it is absent

PHYSICAL CHANNEL RECONFIGURATION (Step 13)

Information Element

Value/Remark

Version

Activation time

(256+CFN-(CFN MOD 8 + 8))MOD 256

New U-RNTI

Not Present

New C-RNTI

Not Present

New DSCH-RNTI

Not Present

RRC State indicator

CELL_DCH

UTRAN DRX cycle length coefficient

Not Present

CN information info

Not Present

URA identity

Not Present

Downlink counter synchronisation info

Not Present

Frequency info

Not Present

Maximum allowed UL TX power

Not Present

CHOICE channel requirement

Not Present

CHOICE mode

FDD

>Downlink PDSCH information

Not Present

Downlink information common for all radio links

– Downlink DPCH info common for all RL

Not Present

– CHOICE mode

FDD

– DPCH compressed mode info

– TGPSI

1

– TGPS Status Flag

Deactivate

– TGCFN

Not Present

– Transmission gap pattern sequence

configuration parameters

Not Present

– TX Diversity mode

Not Present

– SSDT information

Not Present

R99 and Rel-4 only

– Default DPCH Offset Value

Not Present

Downlink information for each radio link

Not Present

MEASUREMENT CONTROL (Step 15)

Information Element

Value/remark

Measurement Identity

14

Measurement Command

Modify

Measurement Reporting Mode

Not Present

Additional measurements list

Not Present

CHOICE measurement type

Not Present

DPCH compressed mode status info

– TGPS reconfiguration CFN

(Current CFN+(256 – TTI/10msec)) mod 256

– Transmission gap pattern sequence

– TGPSI

1

– TGPS Status Flag

Activate

– TGCFN

(Current CFN+(256 – TTI/10msec)) mod 256

MEASUREMENT CONTROL (Step 17)

Information Element

Value/remark

Measurement Identity

14

Measurement Command

Release

Measurement Reporting Mode

Not Present

Additional measurements list

Not Present

CHOICE measurement type

Not Present

DPCH compressed mode status info

– TGPS reconfiguration CFN

(Current CFN+(256 – TTI/10msec)) mod 256

– Transmission gap pattern sequence

– TGPSI

1

– TGPS Flag

Deactivate

– TGCFN

Not present

PHYSICAL CHANNEL RECONFIGURATION (Step 19)

Information Element

Value/Remark

Version

Activation time

Not Present

New U-RNTI

Not Present

New C-RNTI

Not Present

New DSCH-RNTI

Not Present

RRC State indicator

CELL_DCH

UTRAN DRX cycle length coefficient

Not Present

CN information info

Not Present

URA identity

Not Present

Downlink counter synchronisation info

Not Present

Frequency info

Not Present

Maximum allowed UL TX power

Not Present

CHOICE channel requirement

Not Present

CHOICE mode

FDD

– Downlink PDSCH information

Not Present

Downlink information common for all radio links

– Downlink DPCH info common for all RL

Not Present

– CHOICE mode

FDD

– DPCH compressed mode info

– TGPSI

1

– TGPS Status Flag

Activate

– TGCFN

(Current CFN+(256 – TTI/10msec)) mod 256

– Transmission gap pattern sequence

configuration parameters

– TGMP

FDD Measurement

– TGPRC

Infinity

– TGSN

4

– TGL1

7

– TGL2

Not Present

– TGD

undefined

– TGPL1

3

– TGPL2

Not Present

R99 and REL-4 only

– RPP

Mode 0

– ITP

Mode 0

– CHOICE UL/DL Mode

UL and DL, UL only or DL only (depending on the UE capability)

– Downlink compressed mode method

SF/2 (or not sent, depending on the UE capability)

– Uplink compressed mode method

SF/2 (or not sent, depending on the UE capability)

– Downlink frame type

B

– DeltaSIR1

20 (2.0)

– DeltaSIRAfter1

10 (1.0)

– DeltaSIR2

Not Present

– DeltaSIRAfter2

Not Present

– N identify abort

Not Present

– T Reconfirm abort

Not Present

– TX Diversity mode

Not Present

– SSDT information

Not Present

R99 and Rel-4 only

– Default DPCH Offset Value

Not Present

Downlink information for each radio link

– CHOICE mode

FDD

– Primary CPICH info

Set to scrambling code of cell 1

– Cell ID

Not present

– PDSCH with SHO DCH info

Not present

– PDSCH code mapping

Not present

– Downlink DPCH info for each RL

– CHOICE mode

FDD

– Primary CPICH usage for channel estimation

Primary CPICH may be used

– DPCH frame offset

Set to value Default DPCH Offset Value (as currently stored in SS) mod 38400

– Secondary CPICH info

Not present

– DL channelisation code

– Secondary scrambling code

5

– Spreading factor

Reference to TS34.108 clause 6.10 Parameter Set

– Code number

Same as the code currently allocated to the UE

– Scrambling code change

Code change

– TPC combination index

0

– SSDT cell identity

Not present

R99 and Rel-4 only

– Closed loop timing adjustment mode

Not present

8.4.1.8.5 Test Requirement

After step 2, if UE requires compressed mode the UE shall not send any MEASUREMENT REPORT messages on the uplink DCCH of cell 1. If UE do not require compressed mode, the UE shall send a MEASUREMENT REPORT message on the uplink DCCH of cell 1.

After step 4 and 8, UE shall transmit PHYSICAL CHANNEL RECONFIGURATION COMPLETE message on the uplink DCCH using AM RLC.

After step 8, the UE shall start compressed mode using the method specified in the PHYSICAL CHANNEL RECONFIGURATION message sent in step 8.

After step 9 the UE shall transmit a MEASUREMENT REPORT message, containing the IE "measured results" reporting cell 5’s CPICH RSCP. The UE shall also report the triggering of event ‘2c’ by including IE "Event results" in the MEASUREMENT REPORT message.

After step 11 the UE shall send MEASUREMENT REPORT messages, containing cell 5’s CPICH RSCP measured value in IE "Measured results" at 2 seconds interval. The "Event results" IE shall be omitted in these messages.

If UE requires compressed mode, after step 14, the UE shall either not transmit any MEASUREMENT REPORT messages at all, or continue to transmit MEASUREMENT REPORT messages every 2s, but without including IE “Measured results”.

If UE requires compressed mode, after step 15, the UE shall start compressed mode and resume the transmission of MEASUREMENT REPORT messages with identical contents as in those received after step 11.

After step 17, the UE shall deactivate compressed mode.

After step 20, the UE shall not transmit any MEASUREMENT REPORT message to SS.

8.4.1.8a Measurement Control and Report: Inter-frequency measurement for transition from CELL_FACH to CELL_DCH state (TDD)

8.4.1.8a.1 Definition

8.4.1.8a.2 Conformance requirement

Upon transition from CELL_FACH to CELL_DCH state, the UE shall:

if inter-frequency measurements applicable to CELL_DCH state are stored in the variable MEASUREMENT_IDENTITY:

2> if the cell in which the UE transited from CELL_FACH state is included in the active set for the CELL_DCH state, the UE shall:

3> resume the measurement reporting.

2> otherwise, the UE shall:

3> not resume the measurement reporting. The measurement shall be restarted when a MEASUREMENT CONTROL message is received with the corresponding measurement identity.

Reference

3GPP TS 25.331 clause 8.4.1.7.2

8.4.1.8a.3 Test Purpose

1. To confirm that the UE resumes inter-frequency measurements and reporting stored for which the measurement control information has IE "measurement validity" assigned to the value "CELL_DCH", after it re-enters CELL_DCH state from CELL_FACH state.

8.4.1.8a.4 Method of test

Initial Condition

System Simulator: 2 cells – Cells 1 and cell 5 are active.

UE: PS-DCCH+DTCH_DCH (State 6-10) in cell 1 as specified in clause 7.4 of TS 34.108.

Test Procedure

Table 8.4.1.8a-1 illustrates the downlink power to be applied for the 2 cells in this test.

Table 8.4.1.8a-1

Para-meter

Unit

Cell 1

Cell 5

UTRA RF Channel Number

Mid Range Test Frequency

High Range Test Frequency

PCCPCH RSCP

dBm

-60

-75

Test procedure when the initial condition is that the UE is connected to the PS domain:

The UE is in CELL_DCH state in cell 1 (step 1). SS transmits MEASUREMENT CONTROL message to add cell 5 into the IE "inter-frequency cell info" (step 2). SS checks that UE transmit this message, or else SS checks that the UE sends a MEASUREMENT REPORT messages on the uplink DCCH (step 3).

SS sends a PHYSICAL CHANNEL RECONFIGURATION message on the downlink DCCH to move the UE to CELL_FACH state (step 4). The UE shall reconfigure itself to receive and transmit using the common physical channels assigned, and send PHYSICAL CHANNEL RECONFIGURATION COMPLETE on the uplink DCCH (step 5). SS modifies the content of Master Information Block and System Information Block type 12 messages, including cell 5 in the IE "inter-frequency cell info" (step 6) and providing FACH Measurement Occasion Info. SS transmits SYSTEM INFORMATION CHANGE INDICATION message to UE. Once again, SS verifies that the UE does not transmit MEASUREMENT REPORT messages in the uplink direction (step 7).

SS sends PHYSICAL CHANNEL RECONFIGURATION message, and configures dedicated physical (step 8). The UE shall move to CELL_DCH state and then reply with PHYSICAL CHANNEL RECONFIGURATION COMPLETE message (step 9). The UE shall transmit 1 MEASUREMENT REPORT message, containing the selected frequency quality estimate (in this case PCCPCH RSCP) of cell 5. The UE shall also report the triggering of event ‘2c’ in the IE "Event results" of MEASUREMENT REPORT message (step 10).

SS transmits a MEASUREMENT CONTROL message on the downlink DCCH using AM-RLC (step 10). The UE shall transmit MEASUREMENT REPORT messages at 2 seconds interval (step 12).

Expected Sequence

Step

Direction

Message

Comment

UE

SS

1

The initial state of UE is in CELL_DCH state of cell 1.

2

MEASUREMENT CONTROL

SS specifies inter-frequency measurement and reporting parameters for cell 5, with "measurement validity" IE present and "UE state" set to "CELL_DCH".

3

MEASUREMENT REPORT

SS checks that UE transmit this message.

4

PHYSICAL CHANNEL RECONFIGURATION

SS moves the UE to CELL_FACH state.

5

PHYSICAL CHANNEL RECONFIGURATION COMPLETE

UE shall move to CELL_FACH state.

6

Master Information Block

System Information Block type 12

SS modifies MIB and SIB 12 including cell 5 in the list of cells in IE "inter-frequency cell info", and providing FACH Measurement occasion info.

7

SYSTEM INFORMATION CHANGE INDICATION

After SS transmits this message, SS confirms that there are no transmissions of MEASUREMENT REPORT message in the uplink direction.

8

PHYSICAL CHANNEL RECONFIGURATION

SS moves the UE to CELL_DCH state.

9

PHYSICAL CHANNEL RECONFIGURATION COMPLETE

UE shall move to CELL_DCH state.

10

MEASUREMENT REPORT

UE shall resume inter-frequency measurement task for cell 5 and report the measured PCCPCH RSCP value for cell 5.

11

MEASUREMENT CONTROL

SS changes the reporting criteria for cell 5 to ‘periodic reporting’

12

MEASUREMENT REPORT

UE shall begin to transmit this message at 2 seconds interval.

Specific Message Content

Unless explicitly stated, the messages below shall be used for both the CS case and the PS case.

MEASUREMENT CONTROL (Step 2)

Information Element

Value/remark

Measurement Identity

14

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Event Trigger

Additional measurements list

Not Present

CHOICE measurement type

Inter-frequency measurement

– Inter-frequency cell info list

– CHOICE inter-frequency cell removal

No inter-frequency cells removed

– New inter-frequency info list

– Inter-frequency cell id

5

– Frequency info

– CHOICE mode

TDD

– UARFCN (Nt)

UARFCN of the frequency for cell 5

– Cell info

– Cell individual offset

0 dB

– Reference time difference to cell

Not Present

– Read SFN Indicator

FALSE

– CHOICE Mode

TDD

– Primary CCPCH Info

Set to same code as used for cell 5

– Cells for measurement

Not Present

– Inter-frequency measurement quantity

– CHOICE reporting criteria

Inter-frequency reporting criteria

– Filter Coefficient

0

– Measurement quantity for frequency quality estimate

PCCPCH RSCP

– Inter-frequency reporting quantity

– UTRA Carrier RSSI

FALSE

– Frequency quality estimate

FALSE

– Non frequency related cell reporting quantities

– Cell synchronisation information reporting indicator

FALSE

– Cell Identity reporting indicator

TRUE

– CHOICE mode

TDD

– Timeslot ISCP reporting indicator

FALSE

– Proposed TGSN Reporting required

FALSE

– Primary CCPCH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Measurement validity

– UE State

CELL_DCH

– Inter-frequency set update

-UE autonomous update

On with no reporting

– Non autonomous update mode

Not Present

– CHOICE report criteria

Inter-frequency measurement reporting criteria

– Parameters required for each event

– Inter-frequency event identity

2c

– Threshold used frequency

Not Present

– W used frequency

Not Present

– Hysteresis

2 (1 dB)

– Time to trigger

10 seconds

– Reporting cell status

– CHOICE reported cell

Report cells within active and/or monitored set on used frequency or within active and/or monitored set on non-used frequency

– Maximum number of reported cells

2

– Parameters required for each non-used frequency

– Threshold non used frequency

-85 dBm

– W non-used frequency

0.0

DPCH compressed mode status info

Not Present

PHYSICAL CHANNEL RECONFIGURATION (Step 4)

Use the same message sub-type found in TS 34.108 clause 9 titled "(Packet to CELL_FACH from CELL_DCH in PS)".

Information Element

Value/Remark

Version

– Downlink information for each radio link

– Choice mode

TDD

– Primary CCPCH info

For cell 1. Ref. to the Default setting in TS34.108 clause 6.1 (TDD)

– PDSCH with SHO DCH info

Not Present

– PDSCH code mapping

Not Present

– Downlink DPCH info for each RL

Not Present

– SCCPCH Information for FACH

Not Present

R99 and Rel-4 only

Master Information Block (Step 6)

Information Element

Value/Remark

MIB Value Tag

A valid MIB value tag as defined in TS 25.331 that is different from the previous value

System Information Block type 12 (Step 6)

Information Element

Value/remark

FACH measurement occasion info

– FACH Measurement occasion cycle length coefficient

3

– Inter-frequency FDD measurement indicator

FALSE

– Inter-frequency TDD measurement indicator

TRUE

– Inter-RAT measurement indicators

Not Present

Measurement control system information

-Use of HCS

Not used

– Intra-frequency measurement system information

Not Present

– Inter-frequency measurement system information

– Inter-frequency cell info list

– CHOICE inter-frequency cells removal

Not Present

– New inter-frequency info list

– Inter-frequency cell id

Set to id of cell 5

– Cell info

– Cell individual offset

Not Present

– Reference time difference to cell

Not Present

– Read SFN Indicator

FALSE

– CHOICE Mode

TDD

– Primary CCPCH Info

Refer to clause titled "Default settings for cell No.5 (TDD)" in clause 6.1.4

– Primary CCPCH TX power

Not Present

– Timeslot list

Not Present

– Cell selection and Re-selection info

Not Present – use default values

– Inter-RAT measurement system information

Not Present

– Traffic volume measurement system information

Not Present

PHYSICAL CHANNEL RECONFIGURATION (Step 8 only for the PS case)

UE will use the same message sub-type found in [9] TS 34.108 clause 9, which is entitled "(Packet to CELL_DCH from CELL_FACH in PS)".

MEASUREMENT REPORT (Step 3, 10)

Information Element

Value/remark

Measurement identity

Check to see if set to 14

Measured Results

– CHOICE measurement

Check to see if set to "Inter-frequency measured results list"

– Inter-frequency measurement results

– Frequency info

– CHOICE mode

TDD

– UARFCN

Check to see if set to the UARFCN of the frequency for cell 5

– UTRA carrier RSSI

Check to see if it is absent

– Inter-frequency cell measurement results

– Cell measured results

– Cell Identity

Check to see if it is absent

– SFN-SFN observed time difference

Check to see if it is absent

– Cell synchronisation information

Check to see if it is absent

– CHOICE mode

TDD

– Cell parameters Id

Check to see if it’s the same for cell 5

– Timeslot ISCP

Check to see if it is absent

– Proposed TGSN

Check to see if it is absent

– Primary CCPCH Info

Check to see if set to the same code for cell 5

– PCCPCH RSCP

Check to see if it is present

– Pathloss

Check to see if it is absent

Measured Results on RACH

Check to see if it is absent

Event Results

– CHOICE event result

Inter-frequency event results

– Inter-frequency event identity

Check to see if it’s set to ‘2c’

– Inter-frequency cells

– Frequency Info

– CHOICE mode

TDD

– UARFCN

Check to see if set to the UARFCN of the frequency for cell 5

– Non frequency related measurement event results

– Primary CCPCH Info

Check to see if set to the same for cell 5

MEASUREMENT CONTROL (Step 11)

Information Element

Value/remark

Measurement Identity

14

Measurement Command

Set up

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Periodical reporting

Additional measurements list

Not Present

CHOICE measurement type

Inter-frequency measurement

– Inter-frequency cell info list

– CHOICE inter-frequency cell removal

No inter-frequency cells removed

– New inter-frequency info list

– Inter-frequency cell id

5

– Frequency info

– CHOICE mode

TDD

– UARFCN uplink (Nt)

UARFCN of the frequency for cell 5

– Cell info

– Cell individual offset

0 dB

– Reference time difference to cell

Not Present

– Read SFN Indicator

FALSE

– CHOICE Mode

TDD

– Primary CCPCH Info

Set to same as used for cell 5

– Cells for measurement

– Inter-frequency cell id

5

– Inter-frequency measurement quantity

– CHOICE reporting criteria

Inter-frequency reporting criteria

– Filter Coefficient

0

– Measurement quantity for frequency quality estimate

PCCPCH RSCP

– Inter-frequency reporting quantity

– UTRA Carrier RSSI

FALSE

– Frequency quality estimate

FALSE

– Non frequency related cell reporting quantities

– Cell synchronisation information reporting indicator

FALSE

– Cell Identity reporting indicator

TRUE

– CHOICE mode

TDD

– Timeslot ISCP reporting indicator

FALSE

– Proposed TGSN Reporting required

FALSE

– PCCPCH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting cell status

– CHOICE reported cell

Report cells within active and/or monitored set on used frequency or within active and/or monitored set on non-used frequency

– Maximum number of reported cells

2

– Measurement validity

Not Present

– Inter-frequency set update

Not Present

– CHOICE report criteria

Periodic reporting criteria

– Amount of reporting

Infinity

– Reporting interval

2000 milliseconds

DPCH compressed mode status info

Not Present

MEASUREMENT REPORT (Step 12)

Information Element

Value/remark

Measurement identity

Check to see if set to 14

Measured Results

– CHOICE measurement

Check to see if set to "Inter-frequency measured results list"

– Inter-frequency measurement results

– Frequency info

– UARFCN

Check to see if set to the UARFCN of the frequency for cell 5

– UTRA carrier RSSI

Check to see if it is absent

– Inter-frequency cell measurement results

– Cell measured results

– Cell Identity

Check to see if is absent

– Cell synchronisation information

Check to see if it is absent

– CHOICE mode

TDD

– Cell parameters Id

Check to see if it’s the same for cell 5

– Timeslot ISCP

Check to see if it is absent

– Proposed TGSN

Check to see if it is absent

– Primary CCPCH Info

Check to see if set to the same for cell 5

– PCCPCH RSCP

Check to see if it is present

– Pathloss

Check to see if it is absent

– CFN-SFN observed time difference

Check to see if it is absent

Measured Results on RACH

Check to see if it is absent

Event Results

Check to see if it is absent

8.4.1.8a.5 Test Requirement

After step 2,. UE shall send a MEASUREMENT REPORT message on the uplink DCCH of cell 1.

After step 4 and 8, UE shall transmit PHYSICAL CHANNEL RECONFIGURATION COMPLETE message on the uplink DCCH using AM RLC.

After step 9 the UE shall transmit a MEASUREMENT REPORT message, containing the IE "measured results" reporting cell 5’s PCCPCH RSCP. The UE shall also report the triggering of event ‘2c’ by including IE "Event results" in the MEASUREMENT REPORT message.

After step 11 the UE shall send MEASUREMENT REPORT messages, containing cell 5’s PCCPCH RSCP measured value in IE "Measured results" at 2 seconds interval. The "Event results" IE shall be omitted in these messages.

8.4.1.9 Measurement Control and Report: Unsupported measurement in the UE

8.4.1.9.1 Definition

8.4.1.9.2 Conformance requirement

If UTRAN instructs the UE to perform a measurement that is not supported by the UE, the UE shall:

1> retain the measurement configuration that was valid before the MEASUREMENT CONTROL message was received;

1> set the IE "RRC transaction identifier" in the MEASUREMENT CONTROL FAILURE message to the value of "RRC transaction identifier" in the entry for the MEASUREMENT CONTROL message in the table "Accepted transactions" in the variable TRANSACTIONS; and

1> clear that entry.

1> set the cause value in IE "failure cause" to "unsupported measurement";

1> submit the MEASUREMENT CONTROL FAILURE message to lower layers for transmission on the DCCH using AM RLC;

1> continue with any ongoing processes and procedures as if the invalid MEASUREMENT CONTROL message has not been received;

1> and the procedure ends.

Reference

3GPP TS 25.331 clause 8.4.1.4

8.4.1.9.3 Test purpose

1. To confirm that the UE transmits a MEASUREMENT CONTROL FAILURE message, with the value "unsupported measurement" in IE "failure cause" when the SS instructs the UE to perform an unsupported measurement by sending a MEASUREMENT CONTROL message. To confirm that the UE retains its existing valid measurement configuration, after receiving a MEASUREMENT CONTROL message containing an unsupported measurement.

8.4.1.9.4 Method of test

Initial Condition

System Simulator: 1cell

UE: CS-DCCH+DTCH_DCH (State 6-9) or PS-DCCH+DTCH_DCH (State 6-10) in cell 1 as specified in clause 7.4 of TS 34.108, depending on the CN domain supported by the UE.

[Editor’s note: It is assumed in this test that the UE under test does not possess any inter-RAT measurement capability. The mandatory type(s) of measurement capability that shall be implemented by the UE is to be discussed]

Test Procedure

The UE is in the CELL_DCH state. SS sends MEASUREMENT CONTROL message to command the UE to perform internal measurement and reporting for UE transmitted power. The UE shall transmit MEASUREMENT REPORT messages on DCCH at 1 second interval. The SS transmits a MEASUREMENT CONTROL message to configure inter-RAT measurements. The UE hall transmit a MEASUREMENT CONTROL FAILURE message on the uplink DCCH using AM RLC. SS verifies that the UE continues to transmit MEASURMENT REPORT messages on uplink DCCH.

Expected sequence

Step

Direction

Message

Comment

UE

SS

1

The UE is in the CELL_DCH state.

2

MEASUREMENT CONTROL

UE internal measurement and reporting is requested.

3

MEASUREMENT REPORT

Contains estimated reading for UE transmitted power.

4

MEASUREMENT CONTROL

Inter-RAT measurements are requested in this message

5

MEASUREMENT CONTROL FAILURE

The value "unsupported measurement" is set in IE "failure cause".

6

MEASUREMENT REPORT

SS verifies that UE continue to send this message on uplink DCCH.

Specific Message Content

MEASUREMENT CONTROL (Step 2)

Information Element

Value/remark

Measurement Identity

1

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Periodical Reporting

Additional measurements list

Not Present

CHOICE measurement type

UE internal measurement

– UE internal measurement quantity

– CHOICE mode

FDD

– Measurement quantity

UE Transmitted Power

– Filter Coefficient

0

– UE internal reporting quantity

– UE Transmitted Power

TRUE

– CHOICE mode

FDD

– UE Rx-Tx time difference

FALSE

– CHOICE report criteria

Periodical reporting criteria

– Amount of reporting

Infinity

– Reporting interval

1000 msec

DPCH compressed mode status info

Not present

MEASUREMENT REPORT (Step 3 and Step 6)

Information Element

Value/remark

Measurement Identity number

Check to see if it’s set to ‘1’

Measured Results

– CHOICE measurement

Check to see if it’s set to "UE internal measured results"

– CHOICE mode

Check to see if it’s set to "FDD"

– UE Transmitted Power

Check to see if the reported power is compatible with RF class

– UE Rx-Tx report entries

Check to see if it is absent

Measured Results on RACH

Check to see if it is absent

Additional Measured results

Check to see if it is absent

Event results

Check to see if it is absent

MEASUREMENT CONTROL (Step 4)

Information Element

Value/remark

Version

RRC transaction identifier

Select an arbitrary an integer between 0 and 3

Measurement Identity

2

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

Additional measurements list

Not Present

CHOICE measurement type

Inter-RAT measurement

– Inter-RAT cell info list

– CHOICE inter-RAT cell removal

Remove no inter-RAT cells

– New inter-RAT cells

– Inter-RAT cell id

1

– CHOICE Radio Access Technology

GSM

– Cell individual offset

0

– Cell selection and re-selection info

Not Present

– BSIC

Set to the BSIC code of cell 2

– BSIC ARFCN

Set to the ARFCN assigned to cell 2

– Output power

Not Present

– Cells for measurement

– Inter-RAT cell id

2

– Inter-RAT measurement quantity

– CHOICE system

GSM

– Measurement quantity

GSM Carrier RSSI

– Filter Coefficient

0

– BSIC verification required

Not required

– Inter-RAT reporting quantity

– UTRAN estimate quantity

FALSE

– CHOICE system

GSM

– Pathloss

FALSE

– Observed time difference to GSM cell Reporting indicator

FALSE

R99 and Rel-4 only

– GSM Carrier RSSI

TRUE

– Reporting cell status

Not Present

– CHOICE report criteria

No reporting

DPCH compressed mode status info

Not Present

MEASUREMENT CONTROL FAILURE (Step 5)

Information Element

Value/remark

RRC transaction identifier

Check if it is set to the same value of the same IE in the MEASUREMENT CONTROL message sent in Step 4.

Failure cause

Check if it is set to "Unsupported measurement"

8.4.1.9.5 Test requirement

After step 2 the UE shall transmit a MEASUREMENT REPORT messages at 1 second interval. In these messages, the IE "CHOICE measurement" shall be set to "UE internal measured results", and it shall contain the measured UL transmitted power reading in IE "UE Transmitted Power".

After step 4 the UE shall transmit a MEASUREMENT CONTROL FAILURE message. In this message, the value "unsupported measurement" shall be specified in IE "failure cause".

After step 5 the UE shall continue to transmit MEASUREMENT REPORT messages on the uplink DCCH, with the contents of the messages identical to that received by SS after step 2.

8.4.1.10 Measurement Control and Report: Failure (Invalid Message Reception)

8.4.1.10.1 Definition

8.4.1.10.2 Conformance requirement

If the MEASUREMENT CONTROL message contains a protocol error causing the variable PROTOCOL_ERROR_REJECT to be set to TRUE according to TS 25.331 clause 9, the UE shall perform procedure specific error handling as follows. The UE shall:

1> set the IE "RRC transaction identifier" in the MEASUREMENT CONTROL FAILURE message to the value of "RRC transaction identifier" in the entry for the MEASUREMENT CONTROL message in the table "Rejected transactions" in the variable TRANSACTIONS; and

1> clear that entry.

1> set the IE "failure cause" to the cause value "protocol error";

1> include the IE "Protocol error information" with contents set to the value of the variable PROTOCOL_ERROR_INFORMATION;

1> submit the MEASUREMENT CONTROL FAILURE message to lower layers for transmission on the DCCH using AM RLC;

1> continue with any ongoing processes and procedures as if the invalid MEASUREMENT CONTROL message has not been received;

1> and the procedure ends.

Reference

3GPP TS 25.331 clauses 8.4.1.5 and 9.2

8.4.1.10.3 Test Purpose

1. To confirm that the UE continues its ongoing processes and procedures after it has received an invalid MEASUREMENT CONTROL message.

2. To confirm that the UE transmits MEASUREMENT CONTROL FAILURE message, after it has received an invalid MEASUREMENT CONTROL message.

8.4.1.10.4 Method of test

Initial Condition

System Simulator: 1 cell.

UE: CS-DCCH+DTCH_DCH (State 6-9) or PS-DCCH+DTCH_DCH (State 6-10) in cell 1 as specified in clause 7.4 of TS 34.108, depending on the CN domain supported by the UE.

Test Procedure

The UE is initially brought to CELL_DCH. SS transmits a MEASUREMENT CONTROL message to the UE, commanding it to start transmitting report messages for the reporting quantity "UE Transmitted Power". SS waits for the UE to transmit MEASUREMENT RERORT message on the uplink DCCH. After the MEASUREMENT REPORT message is received, SS transmits an invalid MEASUREMENT CONTROL message again. The UE shall reply with MEASURMENT CONTROL FAILURE message as it has detected a protocol error. It shall continue to report its UL transmission power level using MEASUREMENT REPORT messages.

Expected Sequence

Step

Direction

Message

Comment

UE

SS

1

The UE is CELL_DCH state in cell 1.

2

MEASUREMENT CONTROL

SS transmits this message on downlink DCCH to instruct UE to start reporting the quantity "UE transmitted power".

3

MEASUREMENT REPORT

UE shall send this message periodically at 32 seconds interval

4

MEASURMENT CONTROL

See message content.

5

MEASUREMENT CONTROL FAILURE

UE shall continue its current measurement and reporting processes and procedures after sending this message.

6

MEASUREMENT REPORT

UE shall continue to transmit this message to the SS at 32 seconds interval.

Specific Message Content

MEASUREMENT CONTROL (Step 2)

Information Element

Value/remark

Measurement Identity

3

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Periodical Reporting

Additional measurements list

Not Present

CHOICE measurement type

UE internal measurement

– UE internal measurement quantity

– Measurement quantity

UE Transmitted Power

– Filter coefficient

0

– UE internal reporting quantity

– UE Transmitted Power

TRUE

– UE Rx-Tx time difference

FALSE

CHOICE report criteria

Periodical reporting criteria

– Amount of reporting

Infinity

– Reporting interval

32 seconds

DPCH compressed mode status info

Not Present

MEASUREMENT REPORT (Step 3 and Step 6)

Information Element

Value/remark

Measurement identity

Check to see if set to 3

Measured Results

CHOICE measurement

Check to see if set to "UE internal measurement results"

– CHOICE mode

Check to see if it’s set to "FDD"

– UE Transmitted Power

Check to see if the reported power is compatible with RF class

– UE Rx-Tx report entries

Check to see if this IE is absent

Measured Results on RACH

Check to see if this IE is absent

Additional Measured results

Check to see if this IE is absent

Event Results

Check to see if this IE is absent

MEASUREMENT CONTROL (Step 4)

Use the MEASUREMENT CONTROL message as defined in [9] TS 34.108 clause 9, with the following exceptions:

Information Element

Value/Remark

Critical extensions

’FF’H

MEASUREMENT CONTROL FAILURE (Step 5)

Information Element

Value/remark

Failure cause

Check to see if set to "protocol error"

Protocol error information

Check to see if set to " Message extension not comprehended "

8.4.1.10.5 Test Requirement

After step 4 the UE shall transmit MEASUREMENT CONTROL FAILURE message, stating the IE "failure cause" as "protocol error" and IE "protocol error information" as "Message extension not comprehended".

After step 5 the UE shall continue to send MEASUREMENT REPORT, with the measurement identity number set to 3 and "measured results" IE containing measured readings of UE Tx power, at 32 seconds interval.

8.4.1.11 Void

8.4.1.12 Void

8.4.1.13 Void

8.4.1.14 Measurement Control and Report: Cell forbidden to affect reporting range (FDD)

8.4.1.14.1 Definition

8.4.1.14.2 Conformance requirement

The reporting range affects the reporting events 1A and 1B. The reporting range is defined as a function of all the Primary CPICHs in the active set. If the parameter W is set to 0, the reporting range is defined relative to the best Primary CPICH. However, there could be cases where it is good to forbid a specific Primary CPICH to affect the reporting range. This mechanism could be effective if the operator knows by experience that the quality of a Primary CPICH is very unstable in a specific area and therefore should not affect the reporting of the other Primary CPICHs.

The UE shall ignore that a Primary CPICH is forbidden to affect the reporting range if all of the following conditions are fulfilled:

– the Primary CPICH is included in active set; and

– all cells in active set are defined as Primary CPICHs forbidden to affect the reporting range.

Reference

3GPP TS 25.331 clause 14.1.2.1, 14.1.2.2, clause 14.1.5.4

8.4.1.14.3 Test Purpose

1. To confirm that the UE reports the triggering of event 1A to the SS, if a primary CPICH currently measured by the UE enters the reporting range.

2. To confirm that the UE reports the triggering of event 1B to the SS, if a primary CPICH currently measured by the UE leaves the reporting range.

3. To confirm that the UE use the forbidden cell indicated in the MEASUREMENT CONTROL message to affect the reporting range.

4. To confirm that the UE ignores that a primary CPICH is forbidden to affect the reporting range when (a) the primary CPICH concerned is included in active set and (b) all cells in the active set are defined as primary CPICHs forbidden to affect the reporting range.

8.4.1.14.4 Method of test

Initial Condition

System Simulator: 3 cells – Cell 1, cell 2 and cell 3 are active. SCH_Ec is set to 0 dB relative to CPICH_Ec.

UE: CS-DCCH+DTCH _DCH (State 6-9) or PS-DCCH+DTCH_DCH (State 6-10) in cell 1 as specified in clause 7.4 of TS 34.108, depending on the CN domain supported by the UE.

Test Procedure

Table 8.4.1.14-1 illustrates the downlink power to be applied for the 3 cells at various time instants of the test execution. Column marked "T0" denotes the initial conditions. The exact instants on which these values shall be applied are described in the texts in this clause.

Table 8.4.1.14-1

Parameter

Unit

Cell1

Cell2

Cell3

T0

T1

T2

T3

T0

T1

T2

T3

T0

T1

T2

T3

UTRA RF Channel

Mid Range Test Frequency

Mid Range Test Frequency

Mid Range Test Frequency

CPICH Ec

dBm/3.84 MHz

-55

-55

-60

-60

-60

-63

-67

-67

-68

-66

-66

-74

The UE is initially in CELL_DCH state of cell 1.

SS sends a MEASUREMENT CONTROL message with cell 1, cell 2 and cell 3 listed in IE "intra-frequency cell info list". In this message the IE "CHOICE reporting criteria" is set to "intra-frequency measurement report criteria", with the IE "intra-frequency event identity" set to "1A". The IE "reporting range" is set to 9 dB in the MEASUREMENT CONTROL message. The UE shall send a MEASUREMENT REPORT on the uplink DCCH, which contains the IE "Event results" to report that intra-frequency event 1A is triggered by cell 2.

SS executes the active set update procedure, requesting that cell 2 be added to the active set. The UE shall respond with ACTIVE SET UPDATE COMPLETE message on the uplink DCCH and then include cell 2 into its current active set. SS sends a MEASUREMENT CONTROL message to command that cell 1 in the active set is forbidden to affect the reporting range for event 1A. SS reconfigures the downlink transmission power settings according to values in column "T1" in table 8.4.1.14-1. The UE shall transmit a MEASUREMENT REPORT message on the uplink DCCH to report the triggering of intra-frequency event 1A. In this message, the IE "Events results" shall indicate that intra-frequency event 1A is triggered by cell 3. SS executes the active set update procedure, requesting that cell 3 be added to the active set. The UE shall respond with ACTIVE SET UPDATE COMPLETE message on the uplink DCCH and then include cell 3 into its current active set. SS sends a MEASUREMENT CONTROL message to command that cell 1 in the active set is forbidden to affect the reporting range for event 1B. The IE "reporting range" is set to 7 dB in the MEASUREMENT CONTROL message. SS checks that no measurement report is sent by the UE. SS reconfigures the downlink transmission power settings according to values in column "T2" in table 8.4.1.14-1. SS sends a MEASUREMENT CONTROL message to command that cell 1 in the active set to be removed from the "forbidden to affect the reporting range for event 1B" cell list. SS reconfigures the downlink transmission power settings according to values in column "T3" in table 8.4.1.14-1. The UE shall transmit a MEASUREMENT REPORT message on the uplink DCCH to report the triggering of intra-frequency event 1B. In this message, the IE "Events results" shall indicate that intra-frequency event 1B is triggered by cell 3. SS reconfigures the downlink transmission power settings according to values in column "T2" in table 8.4.1.14-1. SS sends a MEASUREMENT CONTROL message to command that all cells in the active set are forbidden to update the reporting range for event 1B. SS reconfigures the downlink transmission power settings according to values in column "T3" in table 8.4.1.14-1. The UE shall transmit a MEASUREMENT REPORT message on the uplink DCCH to report the triggering of intra-frequency event 1B. In these messages, the IE "Events results" shall indicate that intra-frequency event 1B is triggered by cell 3.

Expected sequence

Step

Direction

Message

Comment

UE

SS

1

MEASUREMENT CONTROL

UE is initially in CELL_DCH state in cell 1. Cell 1, cell 2 and cell 3 are listed in IE "Intra-frequency cell info list". The IE "CHOICE reporting criteria" is set to "Intra-frequency measurement reporting criteria" and IE "Intra-frequency event identity" is set to "1A", with IE "reporting range" set to 9 dB.

2

MEASUREMENT REPORT

Measurement made on cell 2 shall trigger event 1A

3

ACTIVE SET UPDATE

SS requests UE to add cell 2 into active set.

4

ACTIVE SET UPDATE COMPLETE

5

MEASUREMENT CONTROL

SS request UE to monitor cell 3 for event ‘1A’. SS set cell 1 to be forbidden to affect reporting range. IE “Reporting Range” set to 7 dB.

5a

SS configures the downlink power according to column ‘T1’ of table 8.4.1.14-1.

6

MEASUREMENT REPORT

Measurement made on cell 3 shall trigger event 1A

6a

ACTIVE SET UPDATE

SS requests UE to add cell 3 into active set.

6b

ACTIVE SET UPDATE COMPLETE

7

MEASUREMENT CONTROL

SS set cell 1 to be forbidden to affect reporting range for event ‘1B’.

7a

SS checks that no measurement report is sent by the UE for 20 seconds.

7b

SS configures the downlink power according to column ‘T2’ of table 8.4.1.14-1.

7c

MEASUREMENT CONTROL

Cell 1 shall not be forbidden to affect event ‘1B’.

7d

SS configures the downlink power according to column ‘T3’ of table 8.4.1.14-1.

8

MEASUREMENT REPORT

Measurement made on cell 3 shall trigger event 1B.

8a

SS configures the downlink power according to column ‘T2’ of table 8.4.1.14-1.

9

Void

9a

Void

10

Void

11

MEASUREMENT CONTROL

SS request UE to monitor cell 3 for event ‘1B’. SS forbids all cells in active list to affect the reporting range. The SS requests UE to report the CPICH RSCP value of the active set cells.

11a

SS configures the downlink power according to column ‘T3’ of table 8.4.1.14-1.

12

MEASUREMENT REPORT

Specific Message Contents

MEASUREMENT CONTROL (Step 1)

The contents of MEASUREMENT CONTROL message for this test step is identical to the same message found in [9] TS 34.108 clause 9 with the following exceptions:

Information Element

Value/remark

RRC transaction identifier

1

Measurement Identity

1

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Event Trigger

Additional measurements list

Not Present

CHOICE measurement type

Intra-frequency measurement

– Intra-frequency cell info list

– CHOICE intra-frequency cell removal

Remove no intra-frequency

– New intra-frequency info list

– Intra-frequency cell id

1

– Cell info

– Cell individual offset

Not present

Absence of this IE is equivalent to default value 0dB

– Reference time difference to cell

Not Present

– Read SFN Indicator

FALSE

– CHOICE Mode

FDD

– Primary CPICH Info

– Primary Scrambling Code

Set to same code as used for cell 1

– Primary CPICH TX power

Not Present

– TX Diversity Indicator

FALSE

– Intra-frequency cell id

2

– Cell info

– Cell individual offset

Not present

Absence of this IE is equivalent to default value 0dB

– Reference time difference to cell

Not Present

– Read SFN Indicator

TRUE

– CHOICE Mode

FDD

– Primary CPICH Info

– Primary Scrambling Code

Set to same code as used for cell 2

– Primary CPICH TX power

Not Present

– TX Diversity Indicator

FALSE

– Intra-frequency cell id

3

– Cell info

– Cell individual offset

Not present

Absence of this IE is equivalent to default value 0dB

– Reference time difference to cell

Not Present

– Read SFN Indicator

TRUE

– CHOICE Mode

FDD

– Primary CPICH Info

– Primary Scrambling Code

Set to same code as used for cell 3

– Primary CPICH TX power

Not Present

– TX Diversity Indicator

FALSE

– Cell for measurement

– Intra-frequency cell id

1, 2 and 3

– Intra-frequency measurement quantity

– Filter Coefficient

0

– Measurement quantity

CPICH RSCP

– Intra-frequency reporting quantity

– Reporting quantities for active set cells

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CPICH Ec/No reporting indicator

FALSE

– CPICH RSCP reporting indicator

FALSE

– Pathloss reporting indicator

FALSE

– Reporting quantities for monitored set cells

– Cell synchronisation information reporting indicator

TRUE

– Cell identity reporting indicator

FALSE

– CPICH Ec/No reporting indicator

FALSE

– CPICH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting quantities for detected cells

Not present

– Reporting cell status

Not present

– Measurement validity

Not present

– CHOICE report criteria

Intra-frequency measurement reporting criteria

– Parameters required for each events

– Intra-frequency event identity

1a

– Triggering conditions 1

Not Present

– Triggering conditions 2

monitored set cells

– Reporting range

18 (9.0 dB)

– Cells forbidden to affect reporting range

Not Present

– W

0

– Hysteresis

0 (0 dB)

– Threshold used frequency

Not Present

– Reporting deactivation threshold

3

– Replacement activation threshold

Not Present

– Time to trigger

0 msec

– Amount of reporting

Infinity

– Reporting interval

4000

– Reporting cell status

– CHOICE reported cells

Report cells within monitored set on used frequency

– Maximum number of reported cells

3

DPCH compressed mode status info

Not Present

MEASUREMENT REPORT (Step 2)

NOTE 1: Cell measured results for cell 3 may or may not be present (depends upon the capability of the UE and test uncertainties in power level)

Information Element

Value/remark

Measurement identity

Check to see if set to 1

Measured Results

– CHOICE measurement

Check to see if set to "Intra-frequency measured results list"

– Intra-frequency measurement results

– Cell measured results

– Cell Identity

Check to see if it is absent

– Cell synchronisation information

Check to see if this IE is present and includes IE COUNT-C-SFN frame difference

– Primary CPICH Info

– Primary Scrambling Code

Check to see if it’s the same code for cell 2

– CPICH Ec/No

Check to see if this IE is absent

– CPICH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

– Cell measured results

– Cell Identity

Check to see if it is absent

– Cell synchronisation information

Check to see if this IE is present and includes IE COUNT-C-SFN frame difference

– Primary CPICH Info

– Primary Scrambling Code

Check to see if it’s the same code for cell 3

– CPICH Ec/No

Check to see if this IE is absent

– CPICH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

Measured Results on RACH

Check to see if this IE is absent

Additional Measured Results

Check to see if this IE is absent

Event Results

Check to see if set to ‘Intra-frequency measurement event results’

– Intra-frequency event identity

Check to see if set to ‘1a’

– Cell measurement event results

– CHOICE Mode

Check to see if set to ‘FDD’

– Primary CPICH info

– Primary Scrambling Code

Check to see if set to the same code for cell 2

ACTIVE SET UPDATE (Step 3)

The contents of ACTIVE SET UPDATE message for this test step is identical to the same message found in Clause 9 of TS 34.108 with the following exceptions:

Information Element

Value/remark

Version

RRC transaction identifier

0

Radio link addition information

– Primary CPICH Info

– Primary Scrambling Code

Set to same code as assigned for cell 2

– Downlink DPCH info for each RL

– CHOICE mode

FDD

– Primary CPICH usage for channel estimation

P-CPICH can be used.

– DPCH frame offset

Calculated value from Cell synchronisation information

– Secondary CPICH info

Not Present

– DL channelisation code

This IE is repeated for all existing downlink DPCHs allocated to the UE

– Secondary scrambling code

1

– Spreading factor

Refer to TS 34.108 clause 6.10.2.4 "Typical radio parameter sets"

– Code Number

For each DPCH, assign the same code number in the current code given in cell 1.

– Scrambling code change

Not Present

– TPC Combination Index

0

– SSDT Cell Identity

Not Present

R99 and Rel-4 only

– Close loop timing adjustment mode

Not Present

– TFCI Combining Indicator

FALSE

– SCCPCH information for FACH

Not Present

R99 and Rel-4 only

Radio link removal information

Not Present

ACTIVE SET UPDATE COMPLETE (Step 4 and 6b)

Information Element

Value/remark

RRC transaction identifier

Check to see if it is set to 0

MEASUREMENT CONTROL (Step 5)

The contents of MEASUREMENT CONTROL message for this test step is identical to the same message found in [9] TS 34.108 clause 9 with the following exceptions:

Information Element

Value/remark

RRC transaction identifier

1

Measurement Identity

1

Measurement Command

Modify

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Event Trigger

Additional measurements list

Not Present

CHOICE measurement type

Intra-frequency measurement

– Intra-frequency cell info list

Not Present

– Intra-frequency measurement quantity

Not Present

– Intra-frequency reporting quantity

Not Present

– CHOICE report criteria

Intra-frequency measurement reporting criteria

– Parameters required for each events

– Intra-frequency event identity

1a

– Triggering conditions 1

Not Present

– Triggering conditions 2

monitored set cells

– Reporting range

14 (7.0 dB)

– Cells forbidden to affect reporting range

– CHOICE Mode

FDD

– Primary CPICH info

– Primary scrambling code

Set to the same code as in cell 1

– W

0

– Hysteresis

0 (0 dB)

– Threshold used frequency

Not Present

– Reporting deactivation threshold

3

– Replacement activation threshold

Not Present

– Time to trigger

0 msec

– Amount of reporting

Infinity

– Reporting interval

4000

– Reporting cell status

– CHOICE reported cells

Report cells within monitored set on used frequency

– Maximum number of reported cells

3

DPCH compressed mode status info

Not Present

MEASUREMENT REPORT (Step 6)

Information Element

Value/remark

Measurement identity

Check to see if set to 1

Measured Results

– CHOICE measurement

Check to see if set to "Intra-frequency measured results list"

– Intra-frequency measurement results

– Cell measured results

– Cell Identity

Check to see if it is absent

– Cell synchronisation information

Check to see if this IE is present and includes IE COUNT-C-SFN frame difference

– Primary CPICH Info

– Primary Scrambling Code

Check to see if it’s the same code for cell 3

– CPICH Ec/No

Check to see if this IE is absent

– CPICH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

Measured Results on RACH

Check to see if this IE is absent

Additional Measured Results

Check to see if this IE is absent

Event Results

Check to see if set to ‘Intra-frequency measurement event results’

– Intra-frequency event identity

Check to see if set to ‘1a’

– Cell measurement event results

– CHOICE Mode

Check to see if set to ‘FDD’

– Primary CPICH info

– Primary Scrambling Code

Check to see if set to the same code for cell 3

ACTIVE SET UPDATE (Step 6a)

The contents of ACTIVE SET UPDATE message for this test step is identical to the same message found in Clause 9 of TS 34.108 with the following exceptions:

Information Element

Value/remark

Version

RRC transaction identifier

0

Radio link addition information

– Primary CPICH Info

– Primary Scrambling Code

Set to same code as assigned for cell 3

– Downlink DPCH info for each RL

– CHOICE mode

FDD

– Primary CPICH usage for channel estimation

P-CPICH can be used.

– DPCH frame offset

Calculated value from Cell synchronisation information

– Secondary CPICH info

Not Present

– DL channelisation code

This IE is repeated for all existing downlink DPCHs allocated to the UE

– Secondary scrambling code

2

– Spreading factor

Refer to TS 34.108 clause 6.10.2.4 "Typical radio parameter sets"

– Code Number

For each DPCH, assign the same code number in the current code given in cell 1.

– Scrambling code change

Not Present

– TPC Combination Index

0

– SSDT Cell Identity

Not Present

R99 and Rel-4 only

– Close loop timing adjustment mode

Not Present

– TFCI Combining Indicator

FALSE

– SCCPCH information for FACH

Not Present

R99 and Rel-4 only

Radio link removal information

Not Present

MEASUREMENT CONTROL (Step 7)

The contents of MEASUREMENT CONTROL message for this test step is identical to the same message found in [9] TS 34.108 clause 9 with the following exceptions:

Information Element

Value/remark

RRC transaction identifier

1

Measurement Identity

1

Measurement Command

Modify

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Event Trigger

Additional measurements list

Not Present

CHOICE measurement type

Intra-frequency measurement

– Intra-frequency cell info list

Not Present

– Intra-frequency measurement quantity

Not Present

– Intra-frequency reporting quantity

Not Present

– CHOICE report criteria

Intra-frequency measurement reporting criteria

– Parameters required for each events

– Intra-frequency event identity

1b

– Triggering conditions 1

Active set cells

– Triggering conditions 2

Not Present

– Reporting range

14 (7.0 dB)

– Cells forbidden to affect reporting range

– CHOICE Mode

FDD

– Primary CPICH info

– Primary scrambling code

Set to the same code as in cell 1

– W

0

– Hysteresis

0 (0 dB)

– Time to trigger

0 msec

– Reporting cell status

– CHOICE reported cells

Report cells within monitored set on used frequency

– Maximum number of reported cells

3

DPCH compressed mode status info

Not Present

MEASUREMENT CONTROL (Step 7c)

The contents of MEASUREMENT CONTROL message for this test step is identical to the same message found in [9] TS 34.108 clause 9 with the following exceptions:

Information Element

Value/remark

RRC transaction identifier

1

Measurement Identity

1

Measurement Command

Modify

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Event Trigger

Additional measurements list

Not Present

CHOICE measurement type

Intra-frequency measurement

– Intra-frequency cell info list

Not Present

– Intra-frequency measurement quantity

Not Present

– Intra-frequency reporting quantity

Not Present

– CHOICE report criteria

Intra-frequency measurement reporting criteria

– Parameters required for each events

– Intra-frequency event identity

1b

– Triggering conditions 1

Active set cells

– Triggering conditions 2

Not Present

– Reporting range

21 (10.5 dB)

– Cells forbidden to affect reporting range

Not Present

– W

0

– Hysteresis

0 (0 dB)

– Time to trigger

0 msec

– Reporting cell status

– CHOICE reported cells

Report cells within monitored set on used frequency

– Maximum number of reported cells

3

DPCH compressed mode status info

Not Present

MEASUREMENT REPORT (Step 8)

Information Element

Value/remark

Measurement identity

Check to see if set to 1

Measured Results

Not Present

Measured Results on RACH

Check to see if this IE is absent

Additional Measured Results

Check to see if this IE is absent

Event Results

Check to see if set to ‘Intra-frequency measurement event results’

– Intra-frequency event identity

Check to see if set to ‘1b’

– Cell measurement event results

– CHOICE Mode

Check to see if set to ‘FDD’

– Primary CPICH info

– Primary Scrambling Code

Check to see if set to the same code for cell 3

MEASUREMENT CONTROL (Step 11)

The contents of MEASUREMENT CONTROL message for this test step is identical to the same message found in Clause 9 of TS 34.108 with the following exceptions:

Information Element

Value/remark

RRC transaction identifier

1

Measurement Identity

1

Measurement Command

Modify

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Event Trigger

Additional measurements list

Not Present

CHOICE measurement type

Intra-frequency measurement

– Intra-frequency cell info list

Not Present

– Intra-frequency measurement quantity

Not Present

– Intra-frequency reporting quantity

– Reporting quantities for active set cells

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CPICH Ec/No reporting indicator

FALSE

– CPICH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting quantities for monitored set cells

– Cell synchronisation information reporting indicator

TRUE

– Cell identity reporting indicator

FALSE

– CPICH Ec/No reporting indicator

FALSE

– CPICH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting quantities for detected cells

Not present

– CHOICE report criteria

Intra-frequency measurement reporting criteria

– Parameters required for each events

– Intra-frequency event identity

1b

– Triggering conditions 1

Active set cells

– Triggering conditions 2

Not Present

– Reporting range

21 (10.5 dB)

– Cells forbidden to affect reporting range

– CHOICE Mode

FDD

– Primary CPICH info

– Primary scrambling code

Set to the same code as in cell 1

– CHOICE Mode

FDD

– Primary CPICH info

– Primary scrambling code

Set to the same code as in cell 2

– CHOICE Mode

FDD

– Primary CPICH info

– Primary scrambling code

Set to the same code as in cell 3

– W

0

– Hysteresis

0 (0 dB)

– Time to trigger

0 msec

– Reporting cell status

– CHOICE reported cells

Report cells within active set

– Maximum number of reported cells

3

DPCH compressed mode status info

Not Present

MEASUREMENT REPORT (Step 12)

Information Element

Value/remark

Measurement identity

Check to see if set to 1

Measured Results

– CHOICE measurement

Check to see if set to "Intra-frequency measured results list"

– Intra-frequency measurement results

– Cell measured results

– Cell Identity

Check to see if it is absent

– Cell synchronisation information

Check to see if it is absent

– Primary CPICH Info

– Primary Scrambling Code

Check to see if it’s the same code for cell 1

– CPICH Ec/No

Check to see if this IE is absent

– CPICH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

– Cell measured results

– Cell Identity

Check to see if it is absent

– Cell synchronisation information

Check to see if it is absent

– Primary CPICH Info

– Primary Scrambling Code

Check to see if it’s the same code for cell 2

– CPICH Ec/No

Check to see if this IE is absent

– CPICH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

– Cell measured results

– Cell Identity

Check to see if it is absent

– Cell synchronisation information

Check to see if it is absent

– Primary CPICH Info

– Primary Scrambling Code

Check to see if it’s the same code for cell 3

– CPICH Ec/No

Check to see if this IE is absent

– CPICH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

Measured Results on RACH

Check to see if this IE is absent

Additional Measured Results

Check to see if this IE is absent

Event Results

Check to see if set to ‘Intra-frequency measurement event results’

– Intra-frequency event identity

Check to see if set to ‘1b’

– Cell measurement event results

– CHOICE Mode

Check to see if set to ‘FDD’

– Primary CPICH info

– Primary Scrambling Code

Check to see if set to the same code for cell 3

8.4.1.14.5 Test requirement

After step 1, the UE shall send a MEASUREMENT REPORT message on the uplink DCCH. The message shall contain the IE "Event results" to report that cell 2 has triggered intra-frequency event 1A.

After step 3, the UE shall send a ACTIVE SET UPDATE COMPLETE message on the uplink DCCH.

After step 5a, the UE shall transmit MEASUREMENT REPORT message on the uplink DCCH. The message shall contain IE "Event results" to report that cell 3 has triggered intra-frequency event 1A.

After step 6a, the UE shall send a ACTIVE SET UPDATE COMPLETE message on the uplink DCCH.

After step 7d, the UE shall transmit MEASUREMENT REPORT message on the uplink DCCH. The message shall contain IE "Event results" to report that cell 3 has triggered intra-frequency event 1B.

After step 11a, the UE shall send a MEASUREMENT REPORT message on the uplink DCCH. The message shall contain IE "Event results" to report that cell 3 has triggered intra-frequency event 1B.

8.4.1.15 Measurement Control and Report: Configuration Incomplete

8.4.1.15.1 Definition

8.4.1.15.2 Conformance requirement

If IE "Traffic volume measurement" is received by the UE in a MEASUREMENT CONTROL message, where IE "measurement command" has the value "setup", but IE "Traffic volume measurement quantity" or IE "Traffic volume reporting quantity" is not received, the UE shall:

1> clear all stored measurement control information related associated to this measurement identity in variable MEASUREMENT_IDENTITY;

1> set the variable CONFIGURATION_INCOMPLETE to TRUE.

If IE "Measurement Reporting Mode" is not received by the UE in MEASUREMENT CONTROL message, where IE "measurement command" has the value "setup", the UE shall:

1> clear all stored measurement control information related associated to this measurement identity in variable MEASUREMENT_IDENTITY;

1> set the variable CONFIGURATION_INCOMPLETE to TRUE.

If IE "Inter-frequency measurement" is received by the UE in a MEASUREMENT CONTROL message, where IE "measurement command" has the value "setup", but IE "Inter-frequency measurement quantity", IE "Inter-frequency reporting quantity" or "CHOICE Report criteria" is not received, the UE shall:

1> clear all stored measurement control information related associated to this measurement identity in variable MEASUREMENT_IDENTITY;

1> set the variable CONFIGURATION_INCOMPLETE to TRUE;

If IE "Intra-frequency measurement" is received by the UE in a MEASUREMENT CONTROL message, where IE "measurement command" has the value "setup", but IE "Intra-frequency measurement quantity", IE "Intra-frequency reporting quantity" or "CHOICE Report criteria" is not received, the UE shall:

1> clear all stored measurement control information related associated to this measurement identity in variable MEASUREMENT_IDENTITY;

1> set the variable CONFIGURATION_INCOMPLETE to TRUE.

If IE "Quality measurement" is received by the UE in a MEASUREMENT CONTROL message, where IE "measurement command" has the value "setup", but IE "Quality reporting quantity" is not received, the UE shall:

1> clear all stored measurement control information related associated to this measurement identity in variable MEASUREMENT_IDENTITY;

1> set the variable CONFIGURATION_INCOMPLETE to TRUE.

If IE "UE internal measurement" is received by the UE in a MEASUREMENT CONTROL message, where IE "measurement command" has the value "setup", but IE "UE internal measurement quantity" or IE "UE internal reporting quantity" is not received, the UE shall:

1> clear all stored measurement control information related associated to this measurement identity in variable MEASUREMENT_IDENTITY;

1> set the variable CONFIGURATION_INCOMPLETE to TRUE.

If the variable CONFIGURATION_INCOMPLETE is set to TRUE, the UE shall:

1> retain the measurement configuration that was valid before the MEASUREMENT CONTROL message was received;

1> set the IE "RRC transaction identifier" in the MEASUREMENT CONTROL FAILURE message to the value of "RRC transaction identifier" in the entry for the MEASUREMENT CONTROL message in the table "Accepted transactions" in the variable TRANSACTIONS and clear that entry;

1> clear the variable CONFIGURATION_INCOMPLETE;

1> set the cause value in IE "failure cause" to "Configuration incomplete";

1> submit the MEASUREMENT CONTROL FAILURE message to lower layers for transmission on the DCCH using AM RLC;

1> continue with any ongoing processes and procedures as if the invalid MEASUREMENT CONTROL message has not been received;

1> and the procedure ends.

Reference

3GPP TS 25.331 clause 8.4.1.4a, 8.6.7.10, 8.6.7.13, 8.6.7.14, 8.6.7.16, 8.6.7.17, 8.6.7.18

8.4.1.15.3 Test Purpose

1. To confirm that the UE sends a MEASUREMENT CONTROL FAILURE message, after receiving a MEASUREMENT CONTROL message with IE "Measurement command" set to "Setup" and the following contents:

– "CHOICE measurement type" IE is set to "Intra-frequency measurement" and "Intra-frequency measurement quantity" is omitted; or

– "CHOICE measurement type" IE is set to "Inter-frequency measurement" and "Inter-frequency reporting quantity" is omitted; or

– "Reporting mode" IE is omitted. or

– "CHOICE measurement type" IE is set to "Quality measurement" and IE "Quality reporting quantity" is omitted or

– "CHOICE measurement type" IE is set to "UE internal measurement" and IE "UE internal measurement quantity" is omitted or

– "CHOICE measurement type" IE is set to "UE internal measurement" and IE "UE internal reporting quantity" is omitted or

– "CHOICE measurement type" IE is set to "Traffic volume measurement" and IE "Traffic volume measurement quantity" is omitted or

– "CHOICE measurement type" IE is set to "Traffic volume measurement" and IE "Traffic volume reporting quantity" is omitted

2. To confirm that the UE set the "failure cause" IE to value "incomplete configuration" in the uplink MEASUREMENT CONTROL FAILURE message.

8.4.1.15.4 Method of test

Initial Condition

System Simulator: 1 cell.

UE: CS-DCCH+DTCH_DCH (State 6-9) or PS-DCCH+DTCH_DCH (State 6-10) in cell 1 as specified in clause 7.4 of TS 34.108, depending on the CN domain supported by the UE.

Test Procedure

The UE is initially brought to CELL_DCH. SS then send a MEASUREMENT CONTROL message to UE. The UE shall perform periodical traffic volume measurement according to this message and then transmit MEASUREMENT REPORT message back to SS.

SS transmits a MEASUREMENT CONTROL message to the UE, commanding it to start an intra-frequency measurement and reporting task. However, IE "Intra-frequency measurement quantity" is absent in the message. The UE shall not establish the intra-frequency measurement. It shall send a MEASUREMENT CONTROL FAILURE message to report that a "configuration incomplete" error has been detected.

Next, SS sends the MEASUREMENT CONTROL message once more. In this message, SS commands the establishment of an inter-frequency measurement and reporting task, but IE "Inter-frequency reporting quantity" is omitted in this message. The UE shall not establish the intra-frequency measurement. It shall send a MEASUREMENT CONTROL FAILURE message to report that a "configuration incomplete" error has been detected.

Next, SS sends a third MEASUREMENT CONTROL message. In this message, SS commands the establishment of an intra-frequency measurement and reporting task, but IE "Measurement reporting mode" is omitted in this message. The UE shall not establish the intra-frequency measurement. It shall send a MEASUREMENT CONTROL FAILURE message to report that a "configuration incomplete" error has been detected.

Next, SS sends a fourth MEASUREMENT CONTROL message. In this message, SS commands the establishment of a quality measurement and reporting task, but IE "Quality reporting quantity" is omitted in this message. The UE shall not establish the quality measurement. It shall send a MEASUREMENT CONTROL FAILURE message to report that a "configuration incomplete" error has been detected.

Next, SS sends a fifth MEASUREMENT CONTROL message. In this message, SS commands the establishment of UE internal measurement and reporting task, but IE "UE internal measurement quantity" is omitted in this message. The UE shall not establish the UE internal measurement. It shall send a MEASUREMENT CONTROL FAILURE message to report that a "configuration incomplete" error has been detected.

Next, SS sends a sixth MEASUREMENT CONTROL message. In this message, SS commands the establishment of UE internal measurement and reporting task, but IE "UE internal reporting quantity" is omitted in this message. The UE shall not establish the UE internal measurement. It shall send a MEASUREMENT CONTROL FAILURE message to report that a "configuration incomplete" error has been detected.

Next, SS sends a seventh MEASUREMENT CONTROL message. In this message, SS commands the establishment of a traffic volume measurement and reporting task, but IE "Traffic volume measurement quantity" is omitted in this message. The UE shall not establish the traffic volume measurement. It shall send a MEASUREMENT CONTROL FAILURE message to report that a "configuration incomplete" error has been detected.

In the final sequence, SS sends an eight MEASUREMENT CONTROL message. In this message, SS commands the establishment of a traffic volume measurement and reporting task, but IE "Traffic volume reporting quantity" is omitted in this message. The UE shall not establish the traffic volume measurement. It shall send a MEASUREMENT CONTROL FAILURE message to report that a "configuration incomplete" error has been detected. UE shall continue its traffic volume measurement and send MEASUREMENT REPORT messages back to SS periodically. SS calls for generic procedure C.3 to check that UE is in CELL_DCH state.

Expected Sequence

Step

Direction

Message

Comment

UE

SS

1

The UE is CELL_DCH state in cell 1.

1a

MEASUREMENT CONTROL

SS requests UE to perform periodical traffic volume measurement.

1b

MEASUREMENT REPORT

2

MEASUREMENT CONTROL

SS commands the start of an intra-frequency measurement and reporting task. IE "Intra-frequency measurement quantity" is absent.

3

MEASUREMENT CONTROL FAILURE

UE reports the occurrence of "incomplete configuration"

4

MEASUREMENT CONTROL

SS commands the start of an inter-frequency measurement and reporting task. IE "Inter-frequency reporting quantity" is absent.

5

MEASUREMENT CONTROL FAILURE

UE reports the occurrence of "incomplete configuration"

6

MEASUREMENT CONTROL

SS commands the start of an inter-frequency measurement and reporting task. IE "Measurement reporting mode" is absent.

7

MEASUREMENT CONTROL FAILURE

UE reports the occurrence of "incomplete configuration"

8

MEASUREMENT CONTROL

SS commands the start of a Quality measurement and reporting task. IE "Quality reporting quantity" is absent.

9

MEASUREMENT CONTROL FAILURE

UE reports the occurrence of "incomplete configuration"

10

MEASUREMENT CONTROL

SS commands the start of an UE internal measurement and reporting task. IE "UE internal measurement quantity" is absent.

11

MEASUREMENT CONTROL FAILURE

UE reports the occurrence of "incomplete configuration"

12

MEASUREMENT CONTROL

SS commands the start of an UE internal measurement and reporting task. IE "UE internal reporting quantity" is absent.

13

MEASUREMENT CONTROL FAILURE

UE reports the occurrence of "incomplete configuration"

14

MEASUREMENT CONTROL

SS commands the start of a Traffic volume measurement and reporting task. IE "Traffic volume measurement quantity" is absent.

15

MEASUREMENT CONTROL FAILURE

UE reports the occurrence of "incomplete configuration"

16

MEASUREMENT CONTROL

SS commands the start of a Traffic volume measurement and reporting task. IE "Traffic volume reporting quantity" is absent.

17

MEASUREMENT CONTROL FAILURE

UE reports the occurrence of "incomplete configuration"

18

MEASUREMENT REPORT

19



CALL C.3

If the test result of C.3 indicates that UE is in CELL_DCH state, the test passes, otherwise it fails.

Specific Message Content

MEASUREMENT CONTROL (Step 1a)

Use the MEASUREMENT CONTROL message as defined in [9] TS 34.108 clause 9, with the following exceptions:

Information Element

Value/Remark

Measurement Identity

1

Measurement Command

Setup

Measurement reporting mode

– Measurement Report Transfer Mode

Acknowledged mode RLC

– Periodical Reporting / Event Trigger Reporting Mode

Periodical Reporting

Additional measurement list

Not Present

CHOICE measurement type

Traffic Volume Measurement

– Traffic volume measurement object list

– Uplink transport channel type

DCH

– UL Target Transport Channel ID

5

– Traffic volume measurement quantity

– Measurement quantity

RLC Buffer Payload

– Time Interval to take an average or a variance

Not Present

– Traffic volume reporting quantity

– RLC Buffer Payload for each RB

True

– Average of RLC Buffer Payload for each RB

False

– Variance of RLC Buffer Payload for each RB

False

– Measurement validity

– UE state

All states

– CHOICE Reporting criteria

Periodical Reporting Criteria

– Amount of reporting

Infinity

– Reporting interval

8000

DPCH compressed mode status

Not Present

MEASUREMENT REPORT (Step 1b and 18)

Check to see if the same message type found in [9] TS 34.108 Clause 9 is received, with the following exceptions:

Information Element

Value/Remarks

Measurement identity

1

Measured Results

– CHOICE measurement

Traffic volume measured results list

– Traffic volume measurement results

– RB identity

1

– RLC buffer payload

Check to see if this IE is present

– RLC buffer payload average

Check to see if this IE is absent

– RLC buffer payload variance

Check to see if this IE is absent

– RB identity

2

– RLC buffer payload

Check to see if this IE is present

– RLC buffer payload average

Check to see if this IE is absent

– RLC buffer payload variance

Check to see if this IE is absent

– RB identity

3

– RLC buffer payload

Check to see if this IE is present

– RLC buffer payload average

Check to see if this IE is absent

– RLC buffer payload variance

Check to see if this IE is absent

– RB identity

4

– RLC buffer payload

Check to see if this IE is present

– RLC buffer payload average

Check to see if this IE is absent

– RLC buffer payload variance

Check to see if this IE is absent

Measured results on RACH

Check to see if this IE is absent

Additional measured results

Check to see if this IE is absent

Event results

Check to see if this IE is absent

MEASUREMENT CONTROL (Step 2)

Information Element

Value/remark

Measurement Identity

1

RRC transaction Identifier

Arbitrarily selected between 0 and 3

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Report Transfer Mode

Acknowledged mode RLC

– Periodical Reporting/Event Trigger Reporting Mode

Periodical reporting

Additional measurements list

Not Present

CHOICE measurement type

Intra-frequency measurement

– Intra-frequency cell info list

– CHOICE intra-frequency cell removal

Remove no intra-frequency cells

– New intra-frequency cell

Not Present

– Cell for measurement

– Intra-frequency cell id

Set to id of cell 1

– Intra-frequency measurement quantity

Not Present

– Intra-frequency reporting quantity

– Reporting quantities for active set cells

– SFN-SFN observed time difference reporting indicator

No report

– Cell synchronization information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CHOICE mode

FDD

– CPICH Ec/No reporting indicator

FALSE

– CPICH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting quantities for monitored set cells

– SFN-SFN observed time difference reporting indicator

No report

– Cell synchronization information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CHOICE mode

FDD

– CPICH Ec/No reporting indicator

FALSE

– CPICH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting cell status

– CHOICE reported cell

Report cells within active set

– Maximum number of reported cells

1

– Measurement validity

CELL_DCH

– CHOICE report criteria

Periodical reporting criteria

– Amount of reporting

Infinity

– Reporting interval

32 seconds

DPCH compressed mode status info

Not Present

MEASUREMENT CONTROL FAILURE (Step 3)

Information Element

Value/remark

RRC transaction identifier

Check if it is set to the same value of the same IE in the MEASUREMENT CONTROL message sent in Step 2

Failure cause

Check to see if set to "incomplete configuration"

MEASUREMENT CONTROL (Step 4) (Note 1)

Information Element

Value/remark

Measurement Identity

2

RRC transaction Identifier

Arbitrarily selected between 0 and 3

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Report Transfer Mode

Acknowledged mode RLC

– Periodical Reporting/Event Trigger Reporting Mode

Periodical reporting

Additional measurements list

Not Present

CHOICE measurement type

Inter-frequency measurement

– Inter-frequency cell info list

– CHOICE inter-frequency cell removal

No inter-frequency cells removed

– New inter-frequency cell

– Inter-frequency cell id

Set to id of cell 4

– Frequency info

– CHOICE Mode

FDD

– UARFCN uplink (Nu)

Set to the same UARFCN as cell 4 in clause 6.1 of TS 34.108

– UARFCN downlink (Nu)

Set to the same UARFCN as cell 4 in clause 6.1 of TS 34.108

– Cell info

– Cell individual offset

0 dB

– Reference time difference to cell

0 chips

– Read SFN Indicator

FALSE

– CHOICE mode

FDD

– Primary CPICH Info

– Primary Scrambling Code

Set to same code as used for cell 4

– Primary CPICH TX power

Not Present

– TX Diversity Indicator

FALSE

– Cell selection and re-selection info

Not Present

– Cell for measurement

– Inter-frequency cell id

Set to id of cell 4

– Inter-frequency measurement quantity

– CHOICE reporting criteria

Inter-frequency reporting criteria

– Filter coefficients

0

– CHOICE mode

FDD

– Measurement quantity for frequency quality estimate

CPICH RSCP

– Inter-frequency reporting quantity

Not Present

– Reporting cell status

– CHOICE reported cell

Report cells within monitored set on non-used frequency

– Maximum number of reported cells

1

– Measurement validity

CELL_DCH

– CHOICE report criteria

Periodical reporting criteria

– Amount of reporting

Infinity

– Reporting interval

32 seconds

– Inter-frequency set update

Not Present

DPCH compressed mode status info

Not Present

MEASUREMENT CONTROL FAILURE (Step 5)

Information Element

Value/remark

RRC transaction identifier

Check if it is set to the same value of the same IE in the MEASUREMENT CONTROL message sent in Step 4

Failure cause

Check to see if set to "incomplete configuration"

MEASUREMENT CONTROL (Step 6)

Information Element

Value/remark

Measurement Identity

3

RRC transaction Identifier

Arbitrarily selected between 0 and 3

Measurement Command

Setup

Measurement Reporting Mode

Not Present

Additional measurements list

Not Present

CHOICE measurement type

Intra-frequency measurement

– Intra-frequency cell info list

– CHOICE intra-frequency cell removal

Remove no intra-frequency cells

– New intra-frequency cell

Not Present

– Cell for measurement

– Intra-frequency cell id

Set to id of cell 1

– Intra-frequency measurement quantity

– Filter coefficient

0

– CHOICE mode

FDD

– Measurement quantity

CPICH RSCP

– Intra-frequency reporting quantity

– Reporting quantities for active set cells

– SFN-SFN observed time difference reporting indicator

No report

– Cell synchronization information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CHOICE mode

FDD

– CPICH Ec/No reporting indicator

FALSE

– CPICH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting quantities for monitored set cells

– SFN-SFN observed time difference reporting indicator

No report

– Cell synchronization information reporting indicator

No report

– Cell identity reporting indicator

FALSE

– CHOICE mode

FDD

– CPICH Ec/No reporting indicator

FALSE

– CPICH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting cell status

– CHOICE reported cell

Report cells within active set

– Maximum number of reported cells

1

– Measurement validity

CELL_DCH

– CHOICE report criteria

Periodical reporting criteria

– Amount of reporting

Infinity

– Reporting interval

32 seconds

DPCH compressed mode status info

Not Present

MEASUREMENT CONTROL FAILURE (Step 7)

Information Element

Value/remark

RRC transaction identifier

Check if it is set to the same value of the same IE in the MEASUREMENT CONTROL message sent in Step 6

Failure cause

Check to see if set to "incomplete configuration"

MEASUREMENT CONTROL (Step 8)

Information Element

Value/remark

Measurement identity

16

Measurement command

Setup

– CHOICE measurement type

Quality measurement

– Quality reporting quantity

Not present

– Reporting criteria

Periodical reporting criteria

– Reporting amount

Infinity

– Reporting interval

64 sec

Measurement reporting mode

– Transfer Mode

Acknowledged mode

– Periodical or event trigger

Periodic

Additional measurement list

Not Present

DPCH compressed mode status

Not Present

MEASUREMENT CONTROL FAILURE (Step 9)

Information Element

Value/remark

RRC transaction identifier

Check if it is set to the same value of the same IE in the MEASUREMENT CONTROL message sent in Step 8

Failure cause

Check to see if set to "incomplete configuration"

MEASUREMENT CONTROL (Step 10)

Information Element

Value/remark

Measurement Identity

1

Measurement Command

Setup

CHOICE measurement type

UE internal measurement

– UE internal measurement quantity

Not present

– UE internal reporting quantity

– UE Transmitted Power

TRUE

– CHOICE mode

FDD

– UE Rx-Tx time difference

FALSE

– CHOICE report criteria

Periodical reporting criteria

– Amount of reporting

Infinity

– Reporting interval

1000 msec

Measurement Reporting Mode

Not Present

Additional measurements list

Not Present

DPCH compressed mode status

Not Present

MEASUREMENT CONTROL FAILURE (Step 11)

Information Element

Value/remark

RRC transaction identifier

Check if it is set to the same value of the same IE in the MEASUREMENT CONTROL message sent in Step 10

Failure cause

Check to see if set to "incomplete configuration"

MEASUREMENT CONTROL (Step 12)

Information Element

Value/remark

Measurement Identity

1

Measurement Command

Setup

CHOICE measurement type

UE internal measurement

– UE internal measurement quantity

– CHOICE mode

FDD

– Measurement quantity

UE Transmitted Power

– Filter Coefficient

0

– UE internal reporting quantity

Not present

– CHOICE report criteria

Periodical reporting criteria

– Amount of reporting

Infinity

– Reporting interval

1000 msec

Measurement Reporting Mode

Not Present

Additional measurements list

Not Present

DPCH compressed mode status

Not Present

MEASUREMENT CONTROL FAILURE (Step 13)

Information Element

Value/remark

RRC transaction identifier

Check if it is set to the same value of the same IE in the MEASUREMENT CONTROL message sent in Step 12

Failure cause

Check to see if set to "incomplete configuration"

MEASUREMENT CONTROL (Step 14)

Information Element

Value/remark

Measurement Identity

1

Measurement Command

Setup

– CHOICE measurement type

Traffic Volume Measurement

– Traffic volume measurement object list

Not Present

– Traffic volume measurement quantity

Not present

– Traffic volume reporting quantity

– RB buffer payload

True

– RB buffer payload average

TRUE

– RB buffer payload variance

False

– Measurement validity

Not Present

– Report criteria

Periodical Reporting Criteria

– Reporting amount

8

– Reporting interval

8 Sec

Measurement reporting mode

– Transfer Mode

Acknowledged mode

– Periodical or event trigger

Periodic

Additional measurement list

Not Present

DPCH compressed mode status

Not Present

MEASUREMENT CONTROL FAILURE (Step 15)

Information Element

Value/remark

RRC transaction identifier

Check if it is set to the same value of the same IE in the MEASUREMENT CONTROL message sent in Step 14

Failure cause

Check to see if set to "incomplete configuration"

MEASUREMENT CONTROL (Step 16)

Information Element

Value/remark

Measurement Identity

1

Measurement Command

Setup

– CHOICE measurement type

Traffic Volume Measurement

– Traffic volume measurement object list

Not Present

– Traffic volume measurement quantity

RLC Buffer Payload

– Traffic volume reporting quantity

Not present

– Measurement validity

Not Present

– Report criteria

Periodical Reporting Criteria

– Reporting amount

8

– Reporting interval

8 Sec

Measurement reporting mode

– Transfer Mode

Acknowledged mode

– Periodical or event trigger

Periodic

Additional measurement list

Not Present

DPCH compressed mode status

Not Present

MEASUREMENT CONTROL FAILURE (Step 17)

Information Element

Value/remark

RRC transaction identifier

Check if it is set to the same value of the same IE in the MEASUREMENT CONTROL message sent in Step 16

Failure cause

Check to see if set to "incomplete configuration"

NOTE: For the MEASUREMENT CONTROL message in step 4, cell 4 is signalled to be added as a new cell into the UE’s inter-frequency cell list. However, SS does not need to transmit cell 4 in the downlink, as the UE is not expected to perform measurement and reporting for this cell.

8.4.1.15.5 Test Requirement

After step 1a, the UE shall transmit a MEASUREMENT REPORT message on the uplink DCCH, reporting the RLC buffer payload of each RBs mapped on DCH at every 8s interval.

After step 2, 4, 6, 8, 10, 12, 14 and step 16, the UE shall transmit MEASUREMENT CONTROL FAILURE message, stating the IE "failure cause" as "incomplete configuration". The UE shall not transmit any MEASUREMENT REPORT messages during the execution of this test case.

After step 17, the UE shall transmit a MEASUREMENT REPORT message on the uplink DCCH, reporting the RLC buffer payload of each RBs mapped on DCH at every 8s interval.

8.4.1.16 Measurement Control and Report: Traffic volume measurement for transition from idle mode to CELL_FACH state

8.4.1.16.1 Definition

8.4.1.16.2 Conformance requirement

Upon transition from idle mode to CELL_FACH state, the UE shall:

1> store the measurement control information from the IE "Traffic volume measurement system information" received in System Information Block type 12 (or System Information Block type 11, according to subclause 8.1.1.6.11) in the variable MEASUREMENT_IDENTITY;

1> begin traffic volume measurement reporting according to the assigned information.

Upon reception of a MEASUREMENT CONTROL message the UE shall perform actions specified in TS 25.331 subclause 8.6 unless otherwise specified below.

The UE shall:

1> read the IE "Measurement command";

1> if the IE "Measurement command" has the value "setup":

2> store this measurement in the variable MEASUREMENT_IDENTITY according to the IE "measurement identity", first releasing any previously stored measurement with that identity if that exists;

2> for measurement types "inter-RAT measurement" or "inter-frequency measurement":

2> for measurement type "UE positioning measurement":

2> for any other measurement type:

3> if the measurement is valid in the current RRC state of the UE:

4> begin measurements according to the stored control information for this measurement identity.

Reference

3GPP TS 25.331 clause 8.4.1.9.4, 3GPP TS 25.331 clause 8.4.1.3.

8.4.1.16.3 Test Purpose

1. To confirm that after a state transition from idle mode to CELL_FACH state, the UE shall begin a traffic volume type measurement, as specified in System Information Block type 11 or 12 messages on BCCH.

2. To confirm that in CELL_FACH state, the UE shall send a MEASUREMENT REPORT message when reporting criteria is satisfied. During CELL_FACH state, if the UE receives a MEASUREMENT CONTROL message, it shall perform the measurement and reporting tasks based on the MEASUREMENT CONTROL message received.

8.4.1.16.4 Method of test

Initial Condition

System Simulator: 1cell

UE: "Registered idle mode on PS" (state 3) in cell 1 as specified in clause 7.4 of TS 34.108. If the UE supports both CS and PS domains, the initial UE state shall be "Registered idle mode on CS/PS" (state 7).

Test Procedure

The UE is initially in idle mode. The System Information Block type 11 message is modified with respect to the default settings to request UE to perform traffic volume measurements. Key measurement parameters are as follows: measurement quantity = "RLC Buffer Payload", report criteria = "periodic reporting criteria", reporting interval = "6 seconds", reporting amount = ‘infinity’. The System Information type 12 message is not broadcasted.

SS prompts the operator to make an outgoing call for one of the traffic classes supported by the UE. SS and UE shall execute procedure P6. Then the UE shall begin traffic volume measurements, and shall send MEASUREMENT REPORT message after completing first measurement. Next SS and UE shall execute procedure P10. Then SS and UE shall execute procedure P14.

UE shall continue to send MEASUREMENT REPORT messages at 6 seconds interval.

SS sends MEASUREMENT CONTROL message to the UE. This message overwrites measurement information saved from System information type 11. Key measurement parameters are as follow: measurement type = "traffic volume measurement", measurement quantity = "RLC Buffer Payload", report criteria = "Event triggered, event 4B: Transport Channel Traffic Volume becomes smaller than an absolute threshold ", Time to trigger = "5 seconds", pending time after trigger = "16 seconds", "reporting threshold = ‘4K’. Since there is no uplink traffic, UE shall send MEASUREMENT REPORT message after 5 seconds (time to trigger interval). SS calls for generic procedure C.2 to check that UE is in CELL_FACH state.

Expected Sequence

Step

Direction

Message

Comment

UE

SS

1

System Information Block type 11

The UE is idle mode and camped onto cell 1. System Information Block type 11 to be transmitted is different from the default settings (see specific message contents)

2

SS executes procedure P6 (clause 7.4.2.2.2) specified in TS 34.108.

SS prompts the test operator to make an outgoing call.

2a

MEASUREMENT REPORT

The UE shall send the first MEASUREMENT REPORT message, as specified in SIB11.

3

SS executes procedure P10 (clause 7.4.2.4.2) specified in TS 34.108.

4

SS executes procedure P14 (clause 7.4.2.6.2) specified in TS 34.108.

5

Void

6

MEASUREMENT REPORT

The report is received within 6 seconds (reporting interval)

7

MEASUREMENT REPORT

Time difference between any two consecutive MEASUREMENT REPORT messages should be 6 Seconds.

8

MEASUREMENT CONTROL

Traffic volume measurement reporting is requested if measurement is below threshold.

9

SS monitors the uplink DCCH to confirm that no MEASUREMENT REPORT messages are received in 5 seconds.

10

MEASUREMENT REPORT

Measurement report because event 4b is triggered

11



CALL C.2

If the test result of C.2 indicates that UE is in CELL_FACH state, the test passes, otherwise it fails.

Specific Message Content

System Information Block type 11 (Step 1) (FDD)

Information Element

Value/remark

SIB12 indicator

FALSE

FACH measurement occasion info

Not Present

Measurement control system information

– Use of HCS

Not used

– Cell selection and reselection quality measure

CPICH RSCP

– Intra-frequency measurement system information

– Intra-frequency measurement identity

Not Present

– Intra-frequency cell info list

– CHOICE intra-frequency cell removal

Remove no intra-frequency cells

– New intra-frequency cells

– Intra-frequency cell id

1

– Cell info

– Cell individual offset

0 dB

– Reference time difference to cell

Not Present

– Read SFN indicator

TRUE

– CHOICE mode

FDD

– Primary CPICH info

– Primary scrambling code

Set to same code as used for cell 1

– Primary CPICH Tx power

Not Present

– TX Diversity indicator

FALSE

– Cells for measurement

Not Present

– Intra-frequency measurement quantity

Not Present

– Intra-frequency reporting quantity for RACH reporting

Not Present

– Maximum number of reported cells on RACH

Not Present

– Reporting information for state CELL_DCH

Not Present

– Inter-frequency measurement system information

Not Present

– Inter-RAT measurement system information

Not Present

– Traffic volume measurement system information

– Traffic volume measurement ID

4

– Traffic volume measurement object list

Rach

– Traffic volume measurement quantity

RLC Buffer Payload

– Traffic volume reporting quantity

– RB buffer payload

True

– RB buffer payload average

False

– RB buffer payload variance

False

– Traffic volume measurement reporting criteria

Not Present

– Measurement validity

All States except CELL_DCH

– Measurement reporting mode

– Measurement report transfer mode

Acknowledged Mode

– Periodical or event trigger

Periodical

– Report criteria system Information

Periodical reporting criteria

– Reporting amount

Infinity

– Reporting interval

6 seconds

System Information Block type 11 (Step 1) (TDD)

Information Element

Value/remark

SIB12 indicator

FALSE

FACH measurement occasion info

Not Present

Measurement control system information

– Use of HCS

Not used

– Intra-frequency measurement system information

– Intra-frequency measurement identity

Not Present

– Intra-frequency cell info list

– CHOICE intra-frequency cell removal

Remove no intra-frequency cells

– New intra-frequency cells

– Intra-frequency cell id

1

– Cell info

– Cell individual offset

0 dB

– Reference time difference to cell

Not Present

– Read SFN indicator

TRUE

– CHOICE mode

TDD

– Primary CCPCH info

Set to same as used for cell 1

– TX Diversity indicator

FALSE

– Cells for measurement

Not Present

– Intra-frequency measurement quantity

Not Present

– Intra-frequency reporting quantity for RACH reporting

Not Present

– Maximum number of reported cells on RACH

Not Present

– Reporting information for state CELL_DCH

Not Present

– Inter-frequency measurement system information

Not Present

– Inter-RAT measurement system information

Not Present

– Traffic volume measurement system information

– Traffic volume measurement ID

4

– Traffic volume measurement object list

RACH

– Traffic volume measurement quantity

RLC Buffer Payload

– Traffic volume reporting quantity

– RB buffer payload

TRUE

– RB buffer payload average

False

– RB buffer payload variance

False

– Traffic volume measurement reporting criteria

Not Present

– Measurement validity

All States except CELL_DCH

– Measurement reporting mode

– Measurement report transfer mode

Acknowledged Mode

– Periodical or event trigger

Periodical

– Report criteria system Information

Periodical reporting criteria

– Reporting amount

Infinity

– Reporting interval

6 seconds

MEASUREMENT REPORT (Step 2a)

The order in which the RBs are reported is not checked.

Information Element

Value/remark

Measurement identity

Check to see if set to 4

Measured Results

– CHOICE measurement

Check to see if set to "traffic volume measured results list"

– Traffic volume measurement results

– RB identity

1

– RLC buffer payload

Check to see if this IE is present

– RLC buffer payload average

Check to see if this IE is absent

– RLC buffer payload variance

Check to see if this IE is absent

– RB identity

2

– RLC buffer payload

Check to see if this IE is present

– RLC buffer payload average

Check to see if this IE is absent

– RLC buffer payload variance

Check to see if this IE is absent

– RB identity

3

– RLC buffer payload

Check to see if this IE is present

– RLC buffer payload average

Check to see if this IE is absent

– RLC buffer payload variance

Check to see if this IE is absent

– RB identity

4

– RLC buffer payload

Check to see if this IE is present

– RLC buffer payload average

Check to see if this IE is absent

– RLC buffer payload variance

Check to see if this IE is absent

Measured results on RACH

Check to see if this IE is absent

Additional measured results

Check to see if this IE is absent

Event results

Check to see if this IE is absent

MEASUREMENT REPORT (Step 6 and 7)

The order in which the RBs are reported is not checked.

Information Element

Value/remark

Measurement identity

Check to see if set to 4

Measured Results

– CHOICE measurement

Check to see if set to "traffic volume measured results list"

– Traffic volume measurement results

– RB identity

1

– RLC buffer payload

Check to see if this IE is present

– RLC buffer payload average

Check to see if this IE is absent

– RLC buffer payload variance

Check to see if this IE is absent

– RB identity

2

– RLC buffer payload

Check to see if this IE is present

– RLC buffer payload average

Check to see if this IE is absent

– RLC buffer payload variance

Check to see if this IE is absent

– RB identity

3

– RLC buffer payload

Check to see if this IE is present

– RLC buffer payload average

Check to see if this IE is absent

– RLC buffer payload variance

Check to see if this IE is absent

– RB identity

4

– RLC buffer payload

Check to see if this IE is present

– RLC buffer payload average

Check to see if this IE is absent

– RLC buffer payload variance

Check to see if this IE is absent

– RB identity

20

– RLC buffer payload

Check to see if this IE is present

– RLC buffer payload average

Check to see if this IE is absent

– RLC buffer payload variance

Check to see if this IE is absent

Measured results on RACH

Check to see if this IE is absent

Additional measured results

Check to see if this IE is absent

Event results

Check to see if this IE is absent

MEASUREMENT CONTROL (Step 8)

Information Element

Value/remark

Measurement Identity

4

Measurement Command

Setup

– CHOICE measurement type

Traffic Volume Measurement

– Traffic volume measurement object list

Not Present

– Traffic volume measurement quantity

RLC Buffer Payload

– Traffic volume reporting quantity

– RB buffer payload

True

– RB buffer payload average

False

– RB buffer payload variance

False

– Measurement validity

Not Present

– CHOICE reporting criteria

Traffic Volume Measurement Reporting Criteria

– Parameters sent for each transport channel

– Uplink transport channel type

Rach

– UL Transport Channel ID

Not Present

– Parameters required for each Event

– Traffic volume event identity

4B

– Reporting threshold

4K

– Time to trigger

5000 ms

– Pending time after trigger

16000 ms

– Tx interruption after trigger

Not Present

Measurement reporting mode

– Transfer Mode

Acknowledged mode

– Periodical or event trigger

Event trigger

Additional measurement list

Not Present

DPCH compressed mode status

Not Present

MEASUREMENT REPORT (Step 10)

The order in which the RBs are reported is not checked.

Information Element

Value/remark

Measurement identity

4

Measured Results

– CHOICE measurement

Traffic volume measured results list

– Traffic volume measurement results

– RB identity

1

– RLC buffer payload

Check to see if this IE is present

– RLC buffer payload average

Check to see if this IE is absent

– RLC buffer payload variance

Check to see if this IE is absent

– RB identity

2

– RLC buffer payload

Check to see if this IE is present

– RLC buffer payload average

Check to see if this IE is absent

– RLC buffer payload variance

Check to see if this IE is absent

– RB identity

3

– RLC buffer payload

Check to see if this IE is present

– RLC buffer payload average

Check to see if this IE is absent

– RLC buffer payload variance

Check to see if this IE is absent

– RB identity

4

– RLC buffer payload

Check to see if this IE is present

– RLC buffer payload average

Check to see if this IE is absent

– RLC buffer payload variance

Check to see if this IE is absent

– RB identity

20

– RLC buffer payload

Check to see if this IE is present

– RLC buffer payload average

Check to see if this IE is absent

– RLC buffer payload variance

Check to see if this IE is absent

Measured results on RACH

Check to see if this IE is absent

Additional measured results

Check to see if this IE is absent

Event results

Traffic Volume Measurement Event Results

– Uplink transport channel type causing the event

Rach

– UL Transport Channel identity

Not Present

– Traffic volume event identity

4B

8.4.1.16.5 Test Requirement

After step 5 the UE shall send MEASUREMENT REPORT messages on the uplink DCCH contain RLC buffer payload information for all SRBs. After 6 seconds UE shall send second MEASUREMENT REPORT messages contain RLC buffer payload information for all SRBs and RAB.

After step 8 the UE shall overwrite measurement information received from system information type 11 with measurement information in MEASUREMENT CONTROL message. The UE shall not send MEASUREMENT REPORT message within time to trigger interval. After step 9 the UE shall transmit MEASUREMENT REPORT messages with event identity 4B.

8.4.1.17 Measurement Control and Report: Traffic volume measurement for transition from idle mode to CELL_DCH state

8.4.1.17.1 Definition

8.4.1.17.2 Conformance requirement

Upon transition from idle mode to CELL_DCH state, the UE shall:

1> begin a traffic volume type measurement, assigned in System Information Block type 11 (or System Information Block type 12.

Upon reception of a MEASUREMENT CONTROL message the UE shall perform actions specified in TS 25.331 subclause 8.6 unless otherwise specified below.

The UE shall:

1> read the IE "Measurement command";

1> if the IE "Measurement command" has the value "setup":

2> store this measurement in the variable MEASUREMENT_IDENTITY according to the IE "measurement identity", first releasing any previously stored measurement with that identity if that exists;

2> for measurement types "inter-RAT measurement" or "inter-frequency measurement":

2> for measurement type "UE positioning measurement":

2> for any other measurement type:

3> if the measurement is valid in the current RRC state of the UE:

4> begin measurements according to the stored control information for this measurement identity.

Reference

3GPP TS 25.331 clause 8.4.1.8.4, 3GPP TS 25.331 clause 8.4.1.3.

8.4.1.17.3 Test Purpose

1. To confirm that after a state transition from idle mode to CELL_DCH state, the UE begin a traffic volume type measurement, as specified in System Information Block type 11 or 12 messages on BCCH. When entering CELL_DCH state, the UE shall send a MEASUREMENT REPORT message when reporting criteria is satisfied.

2. During CELL_DCH state, if the UE receives a MEASUREMENT CONTROL message, it shall perform the measurement and reporting tasks based on the MEASUREMENT CONTROL message received.

8.4.1.17.4 Method of test

Initial Condition

System Simulator: 1cell

UE: "Registered idle mode on CS" (state 2) or "Registered idle mode on PS" (state 3) in cell 1 as specified in clause 7.4 of TS 34.108, depending on the CN domain supported by the UE. If the UE supports both CS and PS domains, the initial UE state shall be "Registered idle mode on CS/PS" (state 7).

Test Procedure

The UE is initially in idle mode. The System Information Block type 11 message is modified with respect to the default settings to request UE to perform traffic volume measurements. Key measurement parameters are as follows: measurement quantity = "Average RLC Buffer Payload", report criteria = "Event triggered, event 4B", reporting threshold = "8K", report transfer mode = "Unacknowledged mode". The System Information type 12 message is not broadcasted.

SS prompts the operator to make an outgoing call of a supported traffic class. SS and UE shall execute procedure P3 (for CS service) or P5 (for PS service). Next SS and UE shall execute procedure P7 (for CS service) or P9 (for PS service). Then SS and UE shall execute procedure P11 (for CS service) or P13 (for PS service).

UE shall begin traffic volume measurements after entering in CELL_DCH state. The UE shall send MEASUREMENT REPORT message because uplink traffic is below threshold.

SS sends MEASUREMENT CONTROL message to the UE. This message reconfigures measurement information saved from System information type 11. Key measurement parameters are as follow: measurement type = "traffic volume measurement", measurement quantity = "RLC Buffer Payload", report criteria = "Periodic reporting criteria", reporting interval = "8 seconds", reporting amount = "8". The UE shall periodically send MEASUREMENT REPORT message to report RLC Buffer Payload for each RB.

SS sends MEASUREMENT CONTROL message to release traffic volume measurement. UE shall not send measurement report after receiving this message. SS calls for generic procedure C.3 to check that UE is in CELL_DCH state.

Expected Sequence

Step

Direction

Message

Comment

UE

SS

1

System Information Block type 11

The UE is idle mode and camped onto cell 1. System Information Block type 11 to be transmitted is different from the default settings (see specific message contents)

2

SS executes procedure P3 (clause 7.4.2.1.2) or P5 (clause 7.4.2.2.2) specified in TS 34.108.

3

SS executes procedure P7 (clause 7.4.2.3.2) or P9 (clause 7.4.2.4.2) specified in TS 34.108.

4

SS executes procedure P11 (clause 7.4.2.5.2) or P13 (clause 7.4.2.6.2) specified in TS 34.108.

5

Void

6

MEASUREMENT REPORT

Event 4B is triggered on DCH 5. This message should come on RB1.

6a

MEASUREMENT REPORT

Event 4B is triggered on DCH 1. This message should come on RB1 (only for PS)

7

MEASUREMENT CONTROL

Periodic Traffic volume measurement reporting is requested.

8

MEASUREMENT REPORT

This message should come on RB2.This MEASUREMENT REPORT shall be received on or before 8 Seconds.

9

MEASUREMENT REPORT

Time difference between earlier and this MEASUREMENT REPORT message should be 8 Seconds.

10

MEASUREMENT CONTROL

Release traffic volume measurement.

11

Wait for 8 Seconds to confirm that UE does not send measurement report message.

12



CALL C.3

If the test result of C.3 indicates that UE is in CELL_DCH state, the test passes, otherwise it fails.

Specific Message Content

System Information Block type 11 (Step 1) (FDD)

Information Element

Value/remark

SIB12 indicator

FALSE

FACH measurement occasion info

Not Present

Measurement control system information

– Use of HCS

Not used

– Cell selection and reselection quality measure

CPICH RSCP

– Intra-frequency measurement system information

– Intra-frequency measurement identity

Not Present

– Intra-frequency cell info list

– CHOICE intra-frequency cell removal

Remove no intra-frequency cells

– New intra-frequency cells

– Intra-frequency cell id

1

– Cell info

– Cell individual offset

0 dB

– Reference time difference to cell

Not Present

– Read SFN indicator

TRUE

– CHOICE mode

FDD

– Primary CPICH info

– Primary scrambling code

Set to same code as used for cell 1

– Primary CPICH Tx power

Not Present

– TX Diversity indicator

FALSE

– Cells for measurement

Not Present

– Intra-frequency measurement quantity

Not Present

– Intra-frequency reporting quantity for RACH reporting

Not Present

– Maximum number of reported cells on RACH

Not Present

– Reporting information for state CELL_DCH

Not Present

– Inter-frequency measurement system information

Not Present

– Inter-RAT measurement system information

Not Present

– Traffic volume measurement system information

– Traffic volume measurement ID

2

– Traffic volume measurement object list

Not Present

– Traffic volume measurement quantity

Average RLC Buffer Payload

– Time Interval to take an average

200 msec

– Traffic volume reporting quantity

– RB buffer payload

False

– RB buffer payload average

True

– RB buffer payload variance

False

– Traffic volume measurement reporting criteria

Not Present

– Measurement validity

CELL_DCH

– Measurement reporting mode

– Measurement report transfer mode

Unacknowledged Mode

– Periodical or event trigger

Event Trigger

– CHOICE reporting criteria

Traffic volume measurement reporting criteria

– Parameters sent for each transport channel

– Uplink transport channel type

Not Present

– UL transport channel id

Not Present

– Parameters required for each Event

– Traffic volume event identity

4B

– Reporting threshold

8K

– Time to trigger

5000 ms

– Pending time after trigger

16000 ms

– Tx interruption after trigger

Not Present

System Information Block type 11 (Step 1) (TDD)

Information Element

Value/remark

SIB12 indicator

FALSE

FACH measurement occasion info

Not Present

Measurement control system information

– Use of HCS

Not used

– Intra-frequency measurement system information

– Intra-frequency measurement identity

Not Present

– Intra-frequency cell info list

– CHOICE intra-frequency cell removal

Remove no intra-frequency cells

– New intra-frequency cells

– Intra-frequency cell id

1

– Cell info

– Cell individual offset

0 dB

– Reference time difference to cell

Not Present

– Read SFN indicator

TRUE

– CHOICE mode

TDD

– Primary CCPCH info

Set to same as used for cell 1

– TX Diversity indicator

FALSE

– Cells for measurement

Not Present

– Intra-frequency measurement quantity

Not Present

– Intra-frequency reporting quantity for RACH reporting

Not Present

– Maximum number of reported cells on RACH

Not Present

– Reporting information for state CELL_DCH

Not Present

– Inter-frequency measurement system information

Not Present

– Inter-RAT measurement system information

Not Present

– Traffic volume measurement system information

– Traffic volume measurement ID

2

– Traffic volume measurement object list

Not Present

– Traffic volume measurement quantity

Average RLC Buffer Payload

– Traffic volume reporting quantity

– Time Interval to take an average

200 msec

– RB buffer payload

FALSE

– RB buffer payload average

TRUE

– RB buffer payload variance

FALSE

– Traffic volume measurement reporting criteria

Not Present

– Measurement validity

CELL_DCH

– Measurement reporting mode

– Measurement report transfer mode

Unacknowledged Mode

– Periodical or event trigger

Event Trigger

– Report criteria system Information

Traffic volume reporting criteria

– Event specific parameters

– Event id

4B

– Reporting threshold

8K

– Time to trigger

5000 ms

– Pending time after trigger

16000 ms

– Tx interruption after trigger

Not Present

MEASUREMENT REPORT (Step 6/6a)

The order in which the RBs are reported is not checked.

Information Element

Value/remark

Measurement identity

Check to see if set to 2

Measured Results

– CHOICE measurement

Check to see if set to "traffic volume measured results list"

– Traffic volume measurement results

– RB identity

1

– RLC buffer payload

Check to see if this IE is absent

– RLC buffer payload average

Check to see if this IE is present

– RLC buffer payload variance

Check to see if this IE is absent

– RB identity

2

– RLC buffer payload

Check to see if this IE is absent

– RLC buffer payload average

Check to see if this IE is present

– RLC buffer payload variance

Check to see if this IE is absent

– RB identity

3

– RLC buffer payload

Check to see if this IE is absent

– RLC buffer payload average

Check to see if this IE is present

– RLC buffer payload variance

Check to see if this IE is absent

– RB identity

4

– RLC buffer payload

Check to see if this IE is absent

– RLC buffer payload average

Check to see if this IE is present

– RLC buffer payload variance

Check to see if this IE is absent

– RB identity

20 (for the PS case only)

– RLC buffer payload

Check to see if this IE is absent

– RLC buffer payload average

Check to see if this IE is present

– RLC buffer payload variance

Check to see if this IE is absent

Measured results on RACH

Check to see if this IE is absent

Additional measured results

Check to see if this IE is absent

Event results

– UL transport channel type causing the event

DCH

– UL Transport Channel identity

5 (step 6), 1(step 6a)

– Traffic volume event identity

4B

MEASUREMENT CONTROL (Step 7)

Information Element

Value/remark

Measurement Identity

2

Measurement Command

Set up

Measurement reporting mode

– Transfer Mode

Acknowledged mode

– Periodical or event trigger

Periodic

Additional measurement list

Not Present

CHOICE measurement type

Traffic Volume Measurement

– Traffic volume measurement object list

– Uplink transport channel type

DCH

– UL Target Transport Channel ID

5

– Traffic volume measurement quantity

– Measurement quantity

RLC Buffer Payload

– Time Interval to take an average or a variance

Not Present

– Traffic volume reporting quantity

– RLC Buffer Payload for each RB

True

– Average of RLC Buffer Payload for each RBe

False

– Variance of RLC Buffer Payload for each RB

False

– Measurement validity

Not Present

– CHOICE Reporting criteria

Periodical Reporting Criteria

– Amount of reporting

8

– Reporting interval

8 Sec

DPCH compressed mode status

Not Present

MEASUREMENT REPORT (Step 8,9)

The order in which the RBs are reported is not checked.

Information Element

Value/remark

Measurement identity

2

Measured Results

– CHOICE measurement

Traffic volume measured results list

– Traffic volume measurement results

– RB identity

1

– RLC buffer payload

Check to see if this IE is present

– RLC buffer payload average

Check to see if this IE is absent

– RLC buffer payload variance

Check to see if this IE is absent

– RB identity

2

– RLC buffer payload

Check to see if this IE is present

– RLC buffer payload average

Check to see if this IE is absent

– RLC buffer payload variance

Check to see if this IE is absent

– RB identity

3

– RLC buffer payload

Check to see if this IE is present

– RLC buffer payload average

Check to see if this IE is absent

– RLC buffer payload variance

Check to see if this IE is absent

– RB identity

4

– RLC buffer payload

Check to see if this IE is present

– RLC buffer payload average

Check to see if this IE is absent

– RLC buffer payload variance

Check to see if this IE is absent

Measured results on RACH

Check to see if this IE is absent

Additional measured results

Check to see if this IE is absent

Event results

Check to see if this IE is absent

MEASUREMENT CONTROL (Step 10)

Information Element

Value/remark

Measurement Identity

2

Measurement Command

Release

Measurement reporting mode

Not Present

Additional measurement list

Not Present

DPCH compressed mode status

Not Present

8.4.1.17.5 Test Requirement

After step 5, due to triggering of event 4B, the UE shall send MEASUREMENT REPORT message using unacknowledged mode of RLC. After step 7, UE shall send MEASUREMENT REPORT message using Acknowledged mode of RLC. After 8 seconds UE shall send second MEASUREMENT REPORT message. After step 10, the UE shall not send MEASUREMENT REPORT message.

8.4.1.18 Measurement Control and Report: Traffic volume measurement for transition from CELL_FACH state to CELL_DCH state

8.4.1.18.1 Definition

8.4.1.18.2 Conformance requirement

Upon transition from CELL_FACH to CELL_DCH state, the UE shall:

– retrieve each set of measurement control information of measurement type "traffic volume" stored;

– if the optional IE "measurement validity" for this measurement has not been included:

– delete the measurement;

– if the IE "measurement validity" for the measurement has been included, and the IE "UE state" has been assigned to value "all states except CELL_DCH":

– stop measurement reporting; and

– save the measurement to be used after the next transition to CELL_FACH state;

– if the IE "measurement validity" for the measurement has been included, and the IE "UE state" has been assigned to value "all states":

– continue measurement reporting;

– if the IE "measurement validity" has been included and the IE "UE state" has been assigned to value "CELL_DCH":

– resume this measurement and associated reporting;

– if no traffic volume type measurement has been assigned to the UE with a MEASUREMENT CONTROL message when transiting to CELL_DCH state:

– continue an ongoing traffic volume type measurement, assigned in System Information Block type 11 or System Information Block type 12.

Reference

3GPP TS 25.331 clause 8.4.1.7.4

8.4.1.18.3 Test Purpose

1. To confirm that the UE performs traffic volume measurements and the associated reporting when it enters CELL_DCH state from CELL_FACH state, and that such measurement contexts (and optionally, the reporting context) valid for CELL_DCH state have been previously stored.

2. To confirm that the UE shall continue to perform traffic volume measurement listed in the System Information Block type 11 or 12 messages, if no previously assigned measurements are present. The UE shall transmit MEASUREMENT REPORT messages if reporting conditions stated in System Information Block type 11 or 12 messages have been satisfied.

8.4.1.18.4 Method of test

Initial Condition

System Simulator: 1 cell

SYSTEM INFORMATION BLOCK TYPE 1 (see specific message contents).

UE: PS-DCCH+DTCH_FACH (state 6-11) as specified in clause 7.4 of TS 34.108

Test Procedure

Initially the UE is in CELL_FACH state. MEASUREMENT CONTROL message is sent to the UE to establish traffic volume measurement context with optional IE "measurement validity" is not present. The UE shall perform measurement and reporting as assigned in MEASUREMENT CONTROL message. RADIO BEARER RECONFIGURATION procedure is used to take the UE from CELL_FACH state to CELL_DCH state. While entering CELL_DCH state from CELL_FACH state, the UE shall delete traffic volume measurement contexts if optional IE "measurement validity" is not present. So, in CELL_DCH state UE shall not perform traffic volume measurement and reporting. UE is taken to the CELL_FACH state from CELL_DCH state using RADIO BEARER RECONFIGURATION procedure. The UE shall not send MEASUREMENT REPORT message as measurement context is already deleted.

The behaviour of the UE when moved from CELL_FACH state to CELL_DCH state and assigned traffic volume measurement context is present with IE "measurement validity" is set to "All But CELL_DCH state" or "CELL_DCH state" or "All states" is tested in a similar way.

When the UE is in CELL_FACH state, System Information is modified to assign traffic volume measurement and reporting to the UE. No previously assigned traffic volume measurement contexts are present in the UE. A SYSTEM INFORMATION CHANGE INDICATION is sent on FACH to inform the UE about the change. The UE is taken to CELL_DCH state from CELL_FACH state using RADIO BEARER RECONFIGURATION procedure. In CELL_DCH state the UE shall continue traffic volume measurement and reporting as assigned in System Information. Traffic volume measurement and reporting is released by sending MEASUREMENT CONTROL message.

Expected Sequence

Step

Direction

Message

Comment

UE

SS

1

MEASUREMENT CONTROL

Optional IE "measurement validity" is not included.

2

MEASUREMENT REPORT

3

RADIO BEARER RECONFIGURATION

4

RADIO BEARER RECONFIGURATION COMPLETE

While entering in CELL_DCH state from CELL_FACH state UE shall delete measurement context setup by MEASUREMENT CONTROL message (Step 1).

5

SS waits for 8 seconds to confirm that there is no MEASUREMENT REPORT message from UE.

6

RADIO BEARER RECONFIGURATION

7

RADIO BEARER RECONFIGURATION COMPLETE

UE is in CELL_FACH state.

8

SS waits for 8 seconds to confirm that there is no MEASUREMENT REPORT message from UE.

9

MEASUREMENT CONTROL

IE "measurement validity" is set to "All But CELL_DCH".

10

MEASUREMENT REPORT

.

11

RADIO BEARER RECONFIGURATION

12

RADIO BEARER RECONFIGURATION COMPLETE

While entering in CELL_DCH state from CELL_FACH state UE shall stop traffic volume measurement setup by MEASUREMENT CONTROL message (Step 9).

13

SS waits for 8 seconds to confirm that there is no MEASUREMENT REPORT message from UE.

14

MEASUREMENT CONTROL

UE shall release measurement context setup by MEASUREMENT CONTROL message (Step 9).

15

RADIO BEARER RECONFIGURATION

16

RADIO BEARER RECONFIGURATION COMPLETE

UE is in CELL_FACH state.

17

MEASUREMENT CONTROL

IE "measurement validity" is set to "CELL_DCH".

18

SS waits for 8 seconds to confirm that there is no MEASUREMENT REPORT message from UE.

19

RADIO BEARER RECONFIGURATION

20

RADIO BEARER RECONFIGURATION COMPLETE

While entering in CELL_DCH state from CELL_FACH state UE shall start traffic volume measurement setup by MEASUREMENT CONTROL message (Step 17).

21

MEASUREMENT REPORT

22

MEASUREMENT CONTROL

UE shall release measurement context setup by MEASUREMENT CONTROL message (Step 17)

23

RADIO BEARER RECONFIGURATION

24

RADIO BEARER RECONFIGURATION COMPLETE

UE is in CELL_FACH state.

25

MEASUREMENT CONTROL

IE "measurement validity" is set to "All states".

26

MEASUREMENT REPORT

27

RADIO BEARER RECONFIGURATION

28

RADIO BEARER RECONFIGURATION COMPLETE

While entering in CELL_DCH state from CELL_FACH state UE shall continue traffic volume measurement setup by MEASUREMENT CONTROL message (Step 25).

29

MEASUREMENT REPORT

30

MEASUREMENT CONTROL

UE shall release measurement context setup by MEASUREMENT CONTROL message (Step 25)

31

RADIO BEARER RECONFIGURATION

32

RADIO BEARER RECONFIGURATION COMPLETE

UE is in CELL_FACH state.

33

MIB, Scheduling Block 1, and SIB12 modified

Traffic volume measurements and reporting is assigned to UE

33a

SYSTEM INFORMATION CHANGE INDICATION

34

MEASUREMENT REPORT

35

RADIO BEARER RECONFIGURATION

36

RADIO BEARER RECONFIGURATION COMPLETE

While entering in CELL_DCH state from CELL_FACH state UE shall continue traffic volume measurement assigned in System Information (Step 33).

37

MEASUREMENT REPORT

38

MEASUREMENT CONTROL

UE shall release measurement context assigned in System Information (Step 33).

Specific Message Content

System Information Block type 1 (FDD or 1.28Mcps TDD)

Use the default system information block with the same type specified in clause 6.1 of TS 34.108, with the following exceptions:

Information Element

Value/remark

– UE Timers and constants in connected mode

– T312

2

MEASUREMENT CONTROL (Step 1)

Information Element

Value/remark

Measurement Identity

1

Measurement Command

Setup

– CHOICE measurement type

Traffic Volume Measurement

– Traffic volume measurement object list

Not Present

– Traffic volume measurement quantity

RLC Buffer Payload

– Traffic volume reporting quantity

– RB buffer payload

True

– RB buffer payload average

False

– RB buffer payload variance

False

– Measurement validity

Not Present

– Report criteria

Periodical Reporting Criteria

– Reporting amount

8

– Reporting interval

8 Sec

Measurement reporting mode

– Transfer Mode

Acknowledged mode

– Periodical or event trigger

Periodic

Additional measurement list

Not Present

DPCH compressed mode status

Not Present

MEASUREMENT REPORT (Step 2)

The order in which the RBs are reported is not checked.

Information Element

Value/remark

Measurement identity

1

Measured Results

– CHOICE measurement

Traffic volume measured results list

– Traffic volume measurement results

– RB identity

1

– RLC buffer payload

Check to see if this IE is present

– RLC buffer payload average

Check to see if this IE is absent

– RLC buffer payload variance

Check to see if this IE is absent

– RB identity

2

– RLC buffer payload

Check to see if this IE is present

– RLC buffer payload average

Check to see if this IE is absent

– RLC buffer payload variance

Check to see if this IE is absent

– RB identity

3

– RLC buffer payload

Check to see if this IE is present

– RLC buffer payload average

Check to see if this IE is absent

– RLC buffer payload variance

Check to see if this IE is absent

– RB identity

4

– RLC buffer payload

Check to see if this IE is present

– RLC buffer payload average

Check to see if this IE is absent

– RLC buffer payload variance

Check to see if this IE is absent

– RB identity

20

– RLC buffer payload

Check to see if this IE is present

– RLC buffer payload average

Check to see if this IE is absent

– RLC buffer payload variance

Check to see if this IE is absent

Measured results on RACH

Check to see if this IE is absent

Additional measured results

Check to see if this IE is absent

Event results

Check to see if this IE is absent

RADIO BEARER RECONFIGURATION (Step 3, 11, 19, 27, and 35)

Use the same message type found in TS 34.108 clause 9 with condition set to A4.

RADIO BEARER RECONFIGURATION (Step 6, 15, 23, and 31)

Use the same message type found in TS 34.108 clause 9 with condition set to A5.

MEASUREMENT CONTROL (Step 9)

The contents of this message are identical to MEASUREMENT CONTROL (Step 1) message with the following exceptions:

Information Element

Value/remark

Measurement Identity

2

Measurement Command

Setup

– CHOICE measurement type

Traffic Volume Measurement

– Measurement validity

All But CELL_DCH

MEASUREMENT REPORT (Step 10)

The contents of this message are identical to MEASUREMENT REPORT (Step 2) message with the following exceptions:

Information Element

Value/Remarks

Measurement identity

2

MEASUREMENT CONTROL (Step 14)

Information Element

Value/remark

Measurement Identity

2

Measurement Command

Release

Measurement reporting mode

Not Present

Additional measurement list

Not Present

DPCH compressed mode status

Not Present

MEASUREMENT CONTROL (Step 17)

The contents of this message are identical to MEASUREMENT CONTROL (Step 1) message with the following exceptions:

Information Element

Value/remark

Measurement Identity

3

Measurement Command

Setup

– CHOICE measurement type

Traffic Volume Measurement

– Measurement validity

CELL_DCH

MEASUREMENT REPORT (Step 21)

The contents of this message are identical to MEASUREMENT REPORT (Step 2) message with the following exceptions:

Information Element

Value/Remarks

Measurement identity

3

MEASUREMENT CONTROL (Step 22)

The contents of this message are identical to MEASUREMENT CONTROL (Step 14) message with the following exceptions:

Information Element

Value/Remark

Measurement Identity

3

MEASUREMENT CONTROL (Step 25)

The contents of this message are identical to MEASUREMENT CONTROL (Step 1) message with the following exceptions:

Information Element

Value/remark

Measurement Identity

4

Measurement Command

Setup

– CHOICE measurement type

Traffic Volume Measurement

– Traffic volume measurement object list

– UL transport channel identity

RACH

– UL transport channel identity

DCH :1

– UL transport channel identity

DCH : 5

– Measurement validity

All States

MEASUREMENT REPORT (Step 26, and 29)

The contents of this message are identical to MEASUREMENT REPORT (Step 2) message with the following exceptions:

Information Element

Value/Remarks

Measurement identity

4

MEASUREMENT CONTROL (Step 30)

The contents of this message are identical to MEASUREMENT CONTROL (Step 14) message with the following exceptions:

Information Element

Value/Remark

Measurement Identity

4

Master Information Block (Step 33)

Information Element

Value/Remarks

MIB Value Tag

A valid MIB value tag as defined in TS 25.331 that is different from the previous value

SB 1 Cell Value tag

Set to (Current SB 1 value tag + 1)

Scheduling Block 1 (Step 33)

Information Element

Value/remark

SIB 12 Cell Value tag

Set to (Current SIB 12 value tag + 1)

System Information Block type 12 (Step 33) (FDD)

Information Element

Value/remark

FACH measurement occasion info

Not Present

Measurement control system information

– Use of HCS

Not used

– Cell selection and reselection quality measure

CPICH RSCP

– Intra-frequency measurement system information

– Intra-frequency measurement identity

Not Present

– Intra-frequency cell info list

– CHOICE intra-frequency cell removal

Remove no intra-frequency cells

– New intra-frequency cells

– Intra-frequency cell id

1

– Cell info

– Cell individual offset

0 dB

– Reference time difference to cell

Not Present

– Read SFN indicator

TRUE

– CHOICE mode

FDD

– Primary CPICH info

– Primary scrambling code

Set to same code as used for cell 1

– Primary CPICH Tx power

Not Present

– TX Diversity indicator

FALSE

– Cells for measurement

Not Present

– Intra-frequency measurement quantity

Not Present

– Intra-frequency reporting quantity for RACH reporting

Not Present

– Maximum number of reported cells on RACH

Not Present

– Reporting information for state CELL_DCH

Not Present

– Inter-frequency measurement system information

Not Present

– Inter-RAT measurement system information

Not Present

– Traffic volume measurement system information

– Traffic volume measurement ID

5

– Traffic volume measurement object list

– UL transport channel identity

RACH

– UL transport channel identity

DCH :1

– UL transport channel identity

DCH : 5

– Traffic volume measurement quantity

RLC Buffer Payload

– Traffic volume reporting quantity

– RB buffer payload

True

– RB buffer payload average

False

– RB buffer payload variance

False

– Traffic volume measurement reporting criteria

Not Present

– Measurement validity

All states

– Measurement reporting mode

– Measurement report transfer mode

Acknowledged Mode

– Periodical or event trigger

Periodical

– Report criteria system Information

Periodical reporting criteria

– Reporting amount

Infinity

– Reporting interval

8 seconds

System Information Block type 12 (Step 1) (TDD)

Information Element

Value/remark

FACH measurement occasion info

Not Present

Measurement control system information

– Use of HCS

Not used

– Intra-frequency measurement system information

– Intra-frequency measurement identity

Not Present

– Intra-frequency cell info list

– CHOICE intra-frequency cell removal

Remove no intra-frequency cells

– New intra-frequency cells

– Intra-frequency cell id

1

– Cell info

– Cell individual offset

0 dB

– Reference time difference to cell

Not Present

– Read SFN indicator

TRUE

– CHOICE mode

TDD

– Primary CCPCH info

Set to same as used for cell 1

– TX Diversity indicator

FALSE

– Cells for measurement

Not Present

– Intra-frequency measurement quantity

Not Present

– Intra-frequency reporting quantity for RACH reporting

Not Present

– Maximum number of reported cells on RACH

Not Present

– Reporting information for state CELL_DCH

Not Present

– Inter-frequency measurement system information

Not Present

– Inter-RAT measurement system information

Not Present

– Traffic volume measurement system information

– Traffic volume measurement ID

5

– Traffic volume measurement object list

– UL transport channel identity

RACH

– UL transport channel identity

DCH :1

– UL transport channel identity

DCH : 5

– Traffic volume measurement quantity

RLC Buffer Payload

– Traffic volume reporting quantity

– RB buffer payload

TRUE

– RB buffer payload average

FALSE

– RB buffer payload variance

FALSE

– Traffic volume measurement reporting criteria

Not Present

– Measurement validity

All states

– Measurement reporting mode

– Measurement report transfer mode

Acknowledged Mode

– Periodical or event trigger

Periodical

– Report criteria system Information

Periodical reporting criteria

– Reporting amount

Infinity

– Reporting interval

8 seconds

SYSTEM INFORMATION CHANGE INDICATION (Step 33a)

Information Element

Value/Remarks

Paging record list

Not Present

BCCH modification info

– MIB Value Tag

A valid MIB value tag as defined in TS 25.331 that is different from the previous value

– BCCH modification time

Not Present

MEASUREMENT REPORT (Step 34, and 37)

The contents of this message are identical to MEASUREMENT REPORT (Step 2) message with the following exceptions:

Information Element

Value/Remarks

Measurement identity

5

MEASUREMENT CONTROL (Step 38)

The contents of this message are identical to MEASUREMENT CONTROL (Step 14) message with the following exceptions:

Information Element

Value/Remark

Measurement Identity

5

8.4.1.18.5 Test Requirement

The UE shall send MEASUREMENT REPORT message in steps 21, 29 and 37. The UE shall not send MEASUREMENT REPORT message in steps 5, 8, and 13.

8.4.1.18a Measurement Control and Report: Traffic volume measurement for transition from Enhanced CELL_FACH state (common E-DCH in UL and HS-DSCH DL) to CELL_DCH state

8.4.1.18a.1 Definition

8.4.1.18a.2 Conformance requirement

Upon transition from CELL_FACH to CELL_DCH state, the UE shall:

1> retrieve each set of measurement control information of measurement type "traffic volume" stored in the variable MEASUREMENT_IDENTITY;

2> if the optional IE "measurement validity" for this measurement has not been included:

3> delete the measurement associated with the variable MEASUREMENT_IDENTITY.

2> if the IE "measurement validity" for the measurement has been included, and the IE "UE state" has been assigned to value "all states except CELL_DCH":

3> stop measurement reporting; and

3> save the measurement associated with the variable MEASUREMENT_IDENTITY to be used after the next transition to CELL_FACH/CELL_PCH/URA_PCH state.

2> if the IE "measurement validity" for the measurement has been included, and the IE "UE state" has been assigned to value "all states":

3> if variable READY_FOR_COMMON_EDCH is set to FALSE before state transition:

4> continue measurement reporting.

3> else:

4> for FDD:

5> resume this measurement and associated reporting.

4> for 1.28 Mcps TDD:

5> continue measurement reporting.

2> if the IE "measurement validity" has been included and the IE "UE state" has been assigned to value "CELL_DCH":

3> resume this measurement and associated reporting.

1> if no traffic volume type measurement has been assigned to the UE with a MEASUREMENT CONTROL message that is valid in CELL_DCH and has the same identity as the one indicated in the IE "Traffic volume measurement system information":

2> store the measurement control information from the IE "Traffic volume measurement system information" received in System Information Block type 12 (or System Information Block type 11, according to subclause 8.1.1.6.11) in the variable MEASUREMENT_IDENTITY;

2> begin traffic volume measurement reporting according to the assigned information.

When a traffic volume measurement is set up, the UE shall:

1> for FDD, if variable READY_FOR_COMMON_EDCH is set to TRUE:

2> if one transport channel that is referenced in the IE "Traffic volume measurement object" as "DCH" and IE "measurement validity" is set to "all states except CELL_DCH":

3> the uplink transport channel on which the UE is supposed to report in CELL_FACH state is of type E-DCH.

1> for 1.28 Mcps TDD, if one transport channel that is referenced in the IE "Traffic volume measurement object" as "USCH" and the IE "UL target transport channel id" is set to 32 and IE "measurement validity" is set to "all states" or "all states except CELL_DCH":

2> the uplink transport channel on which the UE is supposed to report is of type E-DCH.

[…]

Reference

3GPP TS 25.331 clause 8.4.1.7.4, 14.4.2

8.4.1.18a.3 Test Purpose

1. To confirm that the UE performs traffic volume measurements and the associated reporting when it enters CELL_DCH state from enhanced CELL_FACH state (common E-DCH in UL), and that such measurement contexts (and optionally, the reporting context) valid for CELL_DCH state have been previously stored.

2. To confirm that the UE shall continue to perform traffic volume measurement listed in the System Information Block type 11 or 12 messages, if no previously assigned measurements are present. The UE shall transmit MEASUREMENT REPORT messages if reporting conditions stated in System Information Block type 11 or 12 messages have been satisfied.

8.4.1.18a.4 Method of test

Initial Condition

System Simulator: 1 cell

SYSTEM INFORMATION BLOCK TYPE 1 and 5 (see specific message contents).

UE: PS-DCCH+DTCH_FACH (state 6-11) as specified in clause 7.4 of TS 34.108.

Related ICS/IXIT statement(s)

– UE supports FDD or 1.28Mcps TDD

– UE supports common E-DCH

Test Procedure

Initially the UE is in Enhanced CELL_FACH state (common E-DCH in UL). MEASUREMENT CONTROL message is sent to the UE to establish traffic volume measurement context with optional IE "measurement validity" is not present. The UE shall perform measurement and reporting as assigned in MEASUREMENT CONTROL message. RADIO BEARER RECONFIGURATION procedure is used to take the UE from Enhanced CELL_FACH state (common E-DCH in UL) to CELL_DCH state. While entering CELL_DCH state from Enhanced CELL_FACH state (common E-DCH in UL), the UE shall delete traffic volume measurement contexts if optional IE "measurement validity" is not present. So, in CELL_DCH state UE shall not perform traffic volume measurement and reporting. UE is taken to the Enhanced CELL_FACH state (common E-DCH in UL) from CELL_DCH state using RADIO BEARER RECONFIGURATION procedure. The UE shall not send MEASUREMENT REPORT message as measurement context is already deleted.

The behaviour of the UE when moved from Enhanced CELL_FACH state (common E-DCH in UL) to CELL_DCH state and assigned traffic volume measurement context is present with IE "measurement validity" is set to "All But CELL_DCH state" or "CELL_DCH state" or "All states" is tested in a similar way.

When the UE is in Enhanced CELL_FACH state (common E-DCH in UL), System Information is modified to assign traffic volume measurement and reporting to the UE. No previously assigned traffic volume measurement contexts are present in the UE. A SYSTEM INFORMATION CHANGE INDICATION is sent on FACH to inform the UE about the change. The UE is taken to CELL_DCH state from Enhanced CELL_FACH state (common E-DCH in UL) using RADIO BEARER RECONFIGURATION procedure. In CELL_DCH state the UE shall continue traffic volume measurement and reporting as assigned in System Information. Traffic volume measurement and reporting is released by sending MEASUREMENT CONTROL message.

Expected Sequence

Step

Direction

Message

Comment

UE

SS

1

MEASUREMENT CONTROL

Optional IE "measurement validity" is not included.

2

MEASUREMENT REPORT

3

RADIO BEARER RECONFIGURATION

4

RADIO BEARER RECONFIGURATION COMPLETE

While entering in CELL_DCH state from Enhanced CELL_FACH state (common E-DCH in UL) UE shall delete measurement context setup by MEASUREMENT CONTROL message (Step 1).

5

SS waits for 8 seconds to confirm that there is no MEASUREMENT REPORT message from UE.

6

RADIO BEARER RECONFIGURATION

7

RADIO BEARER RECONFIGURATION COMPLETE

UE is in Enhanced CELL_FACH state (common E-DCH in UL).

8

SS waits for 8 seconds to confirm that there is no MEASUREMENT REPORT message from UE.

9

MEASUREMENT CONTROL

IE "measurement validity" is set to "All But CELL_DCH".

10

MEASUREMENT REPORT

.

11

RADIO BEARER RECONFIGURATION

12

RADIO BEARER RECONFIGURATION COMPLETE

While entering in CELL_DCH state from Enhanced CELL_FACH state (common E-DCH in UL) UE shall stop traffic volume measurement setup by MEASUREMENT CONTROL message (Step 9).

13

SS waits for 8 seconds to confirm that there is no MEASUREMENT REPORT message from UE.

14

MEASUREMENT CONTROL

UE shall release measurement context setup by MEASUREMENT CONTROL message (Step 9).

15

RADIO BEARER RECONFIGURATION

16

RADIO BEARER RECONFIGURATION COMPLETE

UE is in Enhanced CELL_FACH state (common E-DCH in UL).

17

MEASUREMENT CONTROL

IE "measurement validity" is set to "CELL_DCH".

18

SS waits for 8 seconds to confirm that there is no MEASUREMENT REPORT message from UE.

19

RADIO BEARER RECONFIGURATION

20

RADIO BEARER RECONFIGURATION COMPLETE

While entering in CELL_DCH state from Enhanced CELL_FACH state (common E-DCH in UL) UE shall start traffic volume measurement setup by MEASUREMENT CONTROL message (Step 17).

21

MEASUREMENT REPORT

22

MEASUREMENT CONTROL

UE shall release measurement context setup by MEASUREMENT CONTROL message (Step 17)

23

RADIO BEARER RECONFIGURATION

24

RADIO BEARER RECONFIGURATION COMPLETE

UE is in Enhanced CELL_FACH state (common E-DCH in UL).

25

MEASUREMENT CONTROL

IE "measurement validity" is set to "All states".

26

MEASUREMENT REPORT

27

RADIO BEARER RECONFIGURATION

28

RADIO BEARER RECONFIGURATION COMPLETE

While entering in CELL_DCH state from Enhanced CELL_FACH state (common E-DCH in UL) UE shall continue traffic volume measurement setup by MEASUREMENT CONTROL message (Step 25).

29

MEASUREMENT REPORT

30

MEASUREMENT CONTROL

UE shall release measurement context setup by MEASUREMENT CONTROL message (Step 25)

31

RADIO BEARER RECONFIGURATION

32

RADIO BEARER RECONFIGURATION COMPLETE

UE is in Enhanced CELL_FACH state (common E-DCH in UL).

33

MIB, Scheduling Block 1, and SIB12 modified

Traffic volume measurements and reporting is assigned to UEs

33a

SYSTEM INFORMATION CHANGE INDICATION

34

MEASUREMENT REPORT

35

RADIO BEARER RECONFIGURATION

36

RADIO BEARER RECONFIGURATION COMPLETE

While entering in CELL_DCH state from Enhanced CELL_FACH state (common E-DCH in UL) UE shall continue traffic volume measurement assigned in System Information (Step 33).

37

MEASUREMENT REPORT

38

MEASUREMENT CONTROL

UE shall release measurement context assigned in System Information (Step 33).

Specific Message Content

System Information Block type 1 (FDD or 1.28Mcps TDD)

Use the default system information block with the same type specified in clause 6.1 of TS 34.108, with the following exceptions:

Information Element

Value/remark

– UE Timers and constants in connected mode

– T312

2

SYSTEM INFORMATION BLOCK TYPE 5 (FDD)

Use the same message type found in clause 6.1 of TS 34.108 condition B3 “Only for cells which configure common E-DCH and HS-DSCH reception in CELL_FACH”..

SYSTEM INFORMATION BLOCK TYPE 5 (1.28Mcps TDD)

Use the same message type found in clause 6.1 of TS 34.108 condition B1 “Only for cells which configure common E-DCH and HS-DSCH reception in CELL_FACH”..

MEASUREMENT CONTROL (Step 1)

Information Element

Value/remark

Measurement Identity

1

Measurement Command

Setup

– CHOICE measurement type

Traffic Volume Measurement

– Traffic volume measurement object list

Not Present

– Traffic volume measurement quantity

RLC Buffer Payload

– Traffic volume reporting quantity

– RB buffer payload

True

– RB buffer payload average

False

– RB buffer payload variance

False

– Measurement validity

Not Present

– Report criteria

Periodical Reporting Criteria

– Reporting amount

8

– Reporting interval

8 Sec

Measurement reporting mode

– Transfer Mode

Acknowledged mode

– Periodical or event trigger

Periodic

Additional measurement list

Not Present

DPCH compressed mode status

Not Present

MEASUREMENT REPORT (Step 2)

The order in which the RBs are reported is not checked.

Information Element

Value/remark

Measurement identity

1

Measured Results

– CHOICE measurement

Traffic volume measured results list

– Traffic volume measurement results

– RB identity

1

– RLC buffer payload

Check to see if this IE is present

– RLC buffer payload average

Check to see if this IE is absent

– RLC buffer payload variance

Check to see if this IE is absent

– RB identity

2

– RLC buffer payload

Check to see if this IE is present

– RLC buffer payload average

Check to see if this IE is absent

– RLC buffer payload variance

Check to see if this IE is absent

– RB identity

3

– RLC buffer payload

Check to see if this IE is present

– RLC buffer payload average

Check to see if this IE is absent

– RLC buffer payload variance

Check to see if this IE is absent

– RB identity

4

– RLC buffer payload

Check to see if this IE is present

– RLC buffer payload average

Check to see if this IE is absent

– RLC buffer payload variance

Check to see if this IE is absent

– RB identity

25

– RLC buffer payload

Check to see if this IE is present

– RLC buffer payload average

Check to see if this IE is absent

– RLC buffer payload variance

Check to see if this IE is absent

Measured results on RACH

Check to see if this IE is absent

Additional measured results

Check to see if this IE is absent

Event results

Check to see if this IE is absent

RADIO BEARER RECONFIGURATION (Step 3, 11, 19, 27, and 35) (FDD)

Use the same message type found in TS 34.108 clause 9 with condition set to A4.

Information Element

Value/remark

– RB information to be affected

Same as the set defined in RADIO BEARER SETUP message found in TS 34.108 clause 9 under condition A30 for SRB1, 2, 3 and 4 and RB25

– Added or Reconfigured UL TrCH information

Same as the set defined in RADIO BEARER SETUP message found in TS 34.108 clause 9 under condition A30

– Added or Reconfigured DL TrCH information

Same as the set defined in RADIO BEARER SETUP message found in TS 34.108 clause 9 under condition A30

– Uplink DPCH info

Same as the set defined in RADIO BEARER SETUP message found in TS 34.108 clause 9 under condition A30

– E-DCH info

Same as the set defined in RADIO BEARER SETUP message found in TS 34.108 clause 9 under condition A30

– Downlink HS-PDSCH Information

Same as the set defined in RADIO BEARER SETUP message found in TS 34.108 clause 9 under condition A30

– Downlink information common for all radio links

Same as the set defined in RADIO BEARER SETUP message found in TS 34.108 clause 9 under condition A30

– Downlink information for each radio link list

Same as the set defined in RADIO BEARER SETUP message found in TS 34.108 clause 9 under condition A30

RADIO BEARER RECONFIGURATION (Step 3, 11, 19, 27, and 35)(1.28Mcps TDD)

Use the same message type found in TS 34.108 clause 9 with condition set to A4.

Information Element

Value/remark

– RB information to be affected

Same as the set defined in RADIO BEARER SETUP message found in TS 34.108 clause 9 under condition A24 for SRB1, 2, 3 and 4 and RB25

– Added or Reconfigured UL TrCH information

Same as the set defined in RADIO BEARER SETUP message found in TS 34.108 clause 9 under condition A24

– Added or Reconfigured DL TrCH information

Same as the set defined in RADIO BEARER SETUP message found in TS 34.108 clause 9 under condition A24

– Uplink DPCH info

Same as the set defined in RADIO BEARER SETUP message found in TS 34.108 clause 9 under condition A24

– E-DCH info

Same as the set defined in RADIO BEARER SETUP message found in TS 34.108 clause 9 under condition A24

– Downlink HS-PDSCH Information

Same as the set defined in RADIO BEARER SETUP message found in TS 34.108 clause 9 under condition A24

– Downlink information common for all radio links

Same as the set defined in RADIO BEARER SETUP message found in TS 34.108 clause 9 under condition A24

– Downlink information for each radio link list

Same as the set defined in RADIO BEARER SETUP message found in TS 34.108 clause 9 under condition A24

RADIO BEARER RECONFIGURATION (Step 6, 15, 23, and 31)

Use the same message as specified for "Packet to CELL_FACH from CELL_DCH in PS" (condition A5) in TS 34.108 clause 9, except for the following, except for the following:

Information Element

Value/remark

– New C-RNTI

‘1010 1010 1010 1011’

– New H-RNTI

‘1010 1010 1010 1011’

– New Primary E-RNTI

‘1010 1010 1010 1011’

– RB information to be affected

– RB identity

1

– RB mapping info

– Information for each multiplexing option

1 RB Mux Option

– RLC logical channel mapping indicator

Not Present

– Number of Uplink RLC logical channels

1

– Uplink transport channel type

E-DCH

– Logical channel identity

1

– E-DCH MAC-d low identity

1

– DDI

1

– CHOICE RLC PDU size

Fixed size

– RLC PDU size list

1 RLC PDU size

– RLC PDU size

144 bits

– Include in scheduling info

FALSE

– MAC logical channel priority

1

– Downlink RLC logical channel info

– Number of RLC logical channels

1

– Downlink transport channel type

HS-DSCH

– DL DCH Transport channel identity

Not present

– DL DSCH Transport channel identity

Not present

– CHOICE DL MAC header type

MAC-ehs

– DL HS-DSCH MAC-ehs Queue ID

0

– Logical channel identity

1

– RB information to be affected

– RB identity

2

– RB mapping info

– Information for each multiplexing option

1 RBMuxOption

– RLC logical channel mapping indicator

Not Present

– Number of RLC logical channels

1

– Uplink transport channel type

E-DCH

– Logical channel identity

2

– E-DCH MAC-d flow identity

1

– DDI

2

– CHOICE RLC PDU size

Fixed size

– RLC PDU size list

1 RLC PDU size

– RLC PDU size

144 bits

– Include in scheduling info

FALSE

– MAC logical channel priority

2

– Downlink RLC logical channel info

– Number of RLC logical channels

1

– Downlink transport channel type

HS-DSCH

– DL DCH Transport channel identity

Not Present

– DL DSCH Transport channel identity

Not Present

– CHOICE DL MAC header type

MAC-ehs

– DL HS-DSCH MAC-ehs Queue Id

1

– Logical channel identity

2

– RB information to be affected

– RB identity

3

– RB mapping info

– Information for each multiplexing option

1 RBMuxOption

– RLC logical channel mapping indicator

Not Present

– Number of RLC logical channels

1

– Uplink transport channel type

E-DCH

– Logical channel identity

3

– E-DCH MAC-d flow identity

1

– CHOICE RLC PDU size

Fixed size

– DDI

3

– RLC PDU size list

1 RLC PDU size

– RLC PDU size

144 bits

– Include in scheduling info

FALSE

– MAC logical channel priority

3

– Downlink RLC logical channel info

– Number of RLC logical channels

1

– Downlink transport channel type

HS-DSCH

– DL DCH Transport channel identity

Not Present

– DL DSCH Transport channel identity

Not Present

– CHOICE DL MAC header type

MAC-ehs

– DL HS-DSCH MAC-ehs Queue Id

1

– Logical channel identity

3

– RB information to be affected

– RB identity

4

– RB mapping info

– Information for each multiplexing option

1 RBMuxOption

– RLC logical channel mapping indicator

Not Present

– Number of RLC logical channels

1

– Uplink transport channel type

E-DCH

– Logical channel identity

4

– E-DCH MAC-d flow identity

1

– CHOICE RLC PDU size

Fixed size

– DDI

4

– RLC PDU size list

1 RLC PDU size

– RLC PDU size

144 bits

– Include in scheduling info

FALSE

– MAC logical channel priority

4

– Downlink RLC logical channel info

– Number of RLC logical channels

1

– Downlink transport channel type

HS-DSCH

– DL DCH Transport channel identity

Not Present

– DL DSCH Transport channel identity

Not Present

– CHOICE DL MAC header type

MAC-ehs

– DL HS-DSCH MAC-ehs Queue Id

1

– Logical channel identity

4

– RB information to be affected

– RB identity

25

– RB mapping info

– Information for each multiplexing option

1 RBMuxOption

– RLC logical channel mapping indicator

Not Present

– Number of RLC logical channels

1

– Uplink transport channel type

E-DCH

– Logical channel identity

7

– E-DCH MAC-d flow identity

1

– CHOICE RLC PDU size

Flexible size

– Length indicator size

15 bit

– Minimum UL RLC PDU size

96 bits

– Largest UL RLC PDU size

400 bits

– Include in scheduling info

FALSE

– MAC logical channel priority

4

– Downlink RLC logical channel info

– Number of RLC logical channels

1

– Downlink transport channel type

HS-DSCH

– DL DCH Transport channel identity

Not Present

– DL DSCH Transport channel identity

Not Present

– CHOICE DL MAC header type

MAC-ehs

– DL HS-DSCH MAC-ehs Queue Id

0

– Logical channel identity

7

Deleted UL TrCH information

– Uplink transport channel type

E-DCH

– E-DCH MAC-d flow identity

3

Deleted DL TrCH information

– Downlink transport channel type

HS-DSCH

– Downlink transport channel type

HS-DSCH

– DL HS-DSCH MAC-ehs reordering queue

3

MEASUREMENT CONTROL (Step 9)

The contents of this message are identical to MEASUREMENT CONTROL (Step 1) message with the following exceptions:

Information Element

Value/remark

Measurement Identity

2

Measurement Command

Setup

– CHOICE measurement type

Traffic Volume Measurement

– Measurement validity

All But CELL_DCH

MEASUREMENT REPORT (Step 10)

The contents of this message are identical to MEASUREMENT REPORT (Step 2) message with the following exceptions:

Information Element

Value/Remarks

Measurement identity

2

MEASUREMENT CONTROL (Step 14)

Information Element

Value/remark

Measurement Identity

2

Measurement Command

Release

Measurement reporting mode

Not Present

Additional measurement list

Not Present

DPCH compressed mode status

Not Present

MEASUREMENT CONTROL (Step 17)

The contents of this message are identical to MEASUREMENT CONTROL (Step 1) message with the following exceptions:

Information Element

Value/remark

Measurement Identity

3

Measurement Command

Setup

– CHOICE measurement type

Traffic Volume Measurement

– Measurement validity

CELL_DCH

MEASUREMENT REPORT (Step 21)

The contents of this message are identical to MEASUREMENT REPORT (Step 2) message with the following exceptions:

Information Element

Value/Remarks

Measurement identity

3

MEASUREMENT CONTROL (Step 22)

The contents of this message are identical to MEASUREMENT CONTROL (Step 14) message with the following exceptions:

Information Element

Value/Remark

Measurement Identity

3

MEASUREMENT CONTROL (Step 25) (FDD)

The contents of this message are identical to MEASUREMENT CONTROL (Step 1) message with the following exceptions:

Information Element

Value/remark

Measurement Identity

4

Measurement Command

Setup

– CHOICE measurement type

Traffic Volume Measurement

– Traffic volume measurement object list

– UL transport channel type

DCH

– UL transport channel identity

1 (Not used as common E-DCH resource used in CELL_FACH state and E-DCH used in CELL_DCH but value must be supplied for ASN.1 backwards compatibility)

– Measurement validity

All States

MEASUREMENT CONTROL (Step 25)(1.28Mcps TDD)

The contents of this message are identical to MEASUREMENT CONTROL (Step 1) message with the following exceptions:

Information Element

Value/remark

Measurement Identity

4

Measurement Command

Setup

– CHOICE measurement type

Traffic Volume Measurement

– Traffic volume measurement object list

– UL transport channel type

USCH

– UL transport channel identity

1 (Not used as common E-DCH resource used in CELL_FACH state and E-DCH used in CELL_DCH but value must be supplied for ASN.1 backwards compatibility)

– Measurement validity

All States

MEASUREMENT REPORT (Step 26, and 29)

The contents of this message are identical to MEASUREMENT REPORT (Step 2) message with the following exceptions:

Information Element

Value/Remarks

Measurement identity

4

MEASUREMENT CONTROL (Step 30)

The contents of this message are identical to MEASUREMENT CONTROL (Step 14) message with the following exceptions:

Information Element

Value/Remark

Measurement Identity

4

Master Information Block (Step 33)

Information Element

Value/Remarks

MIB Value Tag

A valid MIB value tag as defined in TS 25.331 that is different from the previous value

SB 1 Cell Value tag

Set to (Current SB 1 value tag + 1)

Scheduling Block 1 (Step 33)

Information Element

Value/remark

SIB 12 Cell Value tag

Set to (Current SIB 12 value tag + 1)

System Information Block type 12 (Step 33)

Information Element

Value/remark

FACH measurement occasion info

Not Present

Measurement control system information

– Use of HCS

Not used

– Cell selection and reselection quality measure

CPICH RSCP

– Intra-frequency measurement system information

– Intra-frequency measurement identity

Not Present

– Intra-frequency cell info list

– CHOICE intra-frequency cell removal

Remove no intra-frequency cells

– New intra-frequency cells

– Intra-frequency cell id

1

– Cell info

– Cell individual offset

0 dB

– Reference time difference to cell

Not Present

– Read SFN indicator

TRUE

– CHOICE mode

FDD

– Primary CPICH info

– Primary scrambling code

Set to same code as used for cell 1

– Primary CPICH Tx power

Not Present

– TX Diversity indicator

FALSE

– Cells for measurement

Not Present

– Intra-frequency measurement quantity

Not Present

– Intra-frequency reporting quantity for RACH reporting

Not Present

– Maximum number of reported cells on RACH

Not Present

– Reporting information for state CELL_DCH

Not Present

– Inter-frequency measurement system information

Not Present

– Inter-RAT measurement system information

Not Present

– Traffic volume measurement system information

– Traffic volume measurement ID

5

– Traffic volume measurement object list

– UL transport channel type

DCH

– UL transport channel identity

1 (Not used as common E-DCH resource used in CELL_FACH state and E-DCH used in CELL_DCH but value must be supplied for ASN.1 backwards compatibility)

– Traffic volume measurement quantity

RLC Buffer Payload

– Traffic volume reporting quantity

– RB buffer payload

True

– RB buffer payload average

False

– RB buffer payload variance

False

– Traffic volume measurement reporting criteria

Not Present

– Measurement validity

All states

– Measurement reporting mode

– Measurement report transfer mode

Acknowledged Mode

– Periodical or event trigger

Periodical

– Report criteria system Information

Periodical reporting criteria

– Reporting amount

Infinity

– Reporting interval

8 seconds

System Information Block type 12 (Step 33)(1.28Mcps TDD)

Information Element

Value/remark

FACH measurement occasion info

Not Present

Measurement control system information

– Use of HCS

Not used

– Cell selection and reselection quality measure

CPICH RSCP

– Intra-frequency measurement system information

– Intra-frequency measurement identity

Not Present

– Intra-frequency cell info list

– CHOICE intra-frequency cell removal

Remove no intra-frequency cells

– New intra-frequency cells

– Intra-frequency cell id

1

– Cell info

– Cell individual offset

0 dB

– Reference time difference to cell

Not Present

– Read SFN indicator

TRUE

– CHOICE mode

TDD

– Primary CCPCH info

– CHOICE mode

TDD

– CHOICE TDD option

1.28 Mcps TDD

– TSTD indicator

FALSE

– Cell parameters ID

Set to same code as used for cell 1

– SCTD indicator

FALSE

– Primary CCPCH Tx power

Not Present

– Timeslot list

Not Present

– Cells for measurement

Not Present

– Intra-frequency measurement quantity

Not Present

– Intra-frequency reporting quantity for RACH reporting

Not Present

– Maximum number of reported cells on RACH

Not Present

– Reporting information for state CELL_DCH

Not Present

– Inter-frequency measurement system information

Not Present

– Inter-RAT measurement system information

Not Present

– Traffic volume measurement system information

– Traffic volume measurement ID

5

– Traffic volume measurement object list

– UL transport channel type

USCH

– UL transport channel identity

1 (Not used as common E-DCH resource used in CELL_FACH state and E-DCH used in CELL_DCH but value must be supplied for ASN.1 backwards compatibility)

– Traffic volume measurement quantity

RLC Buffer Payload

– Traffic volume reporting quantity

– RB buffer payload

True

– RB buffer payload average

False

– RB buffer payload variance

False

– Traffic volume measurement reporting criteria

Not Present

– Measurement validity

All states

– Measurement reporting mode

– Measurement report transfer mode

Acknowledged Mode

– Periodical or event trigger

Periodical

– Report criteria system Information

Periodical reporting criteria

– Reporting amount

Infinity

– Reporting interval

8 seconds

SYSTEM INFORMATION CHANGE INDICATION (Step 33a)

Information Element

Value/Remarks

Paging record list

Not Present

BCCH modification info

– MIB Value Tag

A valid MIB value tag as defined in TS 25.331 that is different from the previous value

– BCCH modification time

Not Present

MEASUREMENT REPORT (Step 34, and 37)

The contents of this message are identical to MEASUREMENT REPORT (Step 2) message with the following exceptions:

Information Element

Value/Remarks

Measurement identity

5

MEASUREMENT CONTROL (Step 38)

The contents of this message are identical to MEASUREMENT CONTROL (Step 14) message with the following exceptions:

Information Element

Value/Remark

Measurement Identity

5

8.4.1.18a.5 Test Requirement

The UE shall send MEASUREMENT REPORT message in steps 21, 29 and 37. The UE shall not send MEASUREMENT REPORT message in steps 5, 8, and 13.

8.4.1.19 Measurement Control and Report: Traffic volume measurement for transition from CELL_DCH to CELL_FACH state

8.4.1.19.1 Definition

8.4.1.19.2 Conformance requirement

Upon transition from CELL_DCH to CELL_FACH or CELL_PCH or URA_PCH state, the UE shall:

1> retrieve each set of measurement control information of measurement type "traffic volume" stored in the variable MEASUREMENT_IDENTITY; and

2> if the optional IE "measurement validity" for this measurement has not been included:

3> delete the measurement associated with the variable MEASUREMENT_IDENTITY.

2> if the IE "measurement validity" for the measurement has been included, and the IE "UE state" has been assigned to value "CELL_DCH":

3> stop measurement reporting;

3> store the measurement associated with the variable MEASUREMENT_IDENTITY to be used after the next transition to CELL_DCH state.

2> if the IE "measurement validity" for the measurement has been included, and the IE "UE state" has been assigned to value "all states":

3> continue measurement reporting.

2> if the IE "measurement validity" has been included and the IE "UE state" has been assigned to value "all states except CELL_DCH":

3> resume this measurement and associated reporting.

1> if no traffic volume type measurement has been assigned to the UE with a MEASUREMENT CONTROL message that is valid in CELL_FACH or CELL_PCH or URA_PCH states (stored in the variable MEASUREMENT_IDENTITY), which has the same identity as the one indicated in the IE "Traffic volume measurement system information":

2> store the measurement control information from the IE "Traffic volume measurement system information" received in System Information Block type 12 (or System Information Block type 11, according to subclause 8.1.1.6.11) in the variable MEASUREMENT_IDENTITY;

2> begin traffic volume measurement reporting according to the assigned information.

Reference

3GPP TS 25.331 clauses 8.4.1.6.6.

8.4.1.19.3 Test Purpose

1. The UE shall performs traffic volume measurements and the associated reporting when it enters CELL_FACH state from CELL_DCH state, and that such measurement contexts (and optionally, the reporting context) valid for CELL_FACH state have been previously stored.

2. The UE shall perform traffic volume measurement listed in the System Information Block type 11 or 12 messages, if no previously assigned measurements are present. The UE shall transmit MEASUREMENT REPORT messages if reporting conditions has been satisfied.

Reference

3GPP TS 25.331 clause 8.4.1.6.6

8.4.1.19.4 Method of test

Initial Condition

System Simulator: 1 cell

SYSTEM INFORMATION BLOCK TYPE 1 (see specific message contents).

UE: PS-DCCH+DTCH_DCH (state 6-10) as specified in clause 7.4 of TS 34.108

Test Procedure

Initially the UE is in CELL_DCH state. MEASUREMENT CONTROL message is sent to the UE to establish traffic volume measurement context with optional IE "measurement validity" is not present. The UE shall perform measurement and reporting as assigned in MEASUREMENT CONTROL message. RADIO BEARER RECONFIGURATION procedure is used to take the UE from CELL_DCH state to CELL_FACH state. While entering CELL_FACH state from CELL_DCH state, the UE shall delete traffic volume measurement contexts if optional IE "measurement validity" is not present. So, in CELL_FACH state UE shall not perform traffic volume measurement and reporting. UE is taken to the CELL_DCH state from CELL_FACH state using RADIO BEARER RECONFIGURATION procedure. The UE shall not send MEASUREMENT REPORT message as measurement context is already deleted.

The behaviour of the UE when moved from CELL_DCH state to CELL_FACH state and assigned traffic volume measurement context is present with IE "measurement validity" is set to "All But CELL_DCH state" or "CELL_DCH state" or "All states" is tested in a similar way.

When the UE is in CELL_DCH state, System Information is modified to assign traffic volume measurement and reporting to the UE. No previously assigned traffic volume measurement contexts are present in the UE. The UE is taken to CELL_FACH state from CELL_DCH state using RADIO BEARER RECONFIGURATION procedure. In CELL_FACH state the UE shall perform traffic volume measurement and reporting as assigned in System Information. Traffic volume measurement and reporting is released by sending MEASUREMENT CONTROL message.

Expected Sequence

Step

Direction

Message

Comment

UE

SS

1

MEASUREMENT CONTROL

Optional IE "measurement validity" is not included.

2

MEASUREMENT REPORT

3

RADIO BEARER RECONFIGURATION

4

RADIO BEARER RECONFIGURATION COMPLETE

While entering in CELL_FACH state from CELL_DCH state UE shall delete measurement context setup by MEASUREMENT CONTROL message (Step 1).

5

SS waits for 8 seconds to confirm that there is no MEASUREMENT REPORT message from UE.

6

RADIO BEARER RECONFIGURATION

7

RADIO BEARER RECONFIGURATION COMPLETE

UE is in CELL_DCH state.

8

SS waits for 8 seconds to confirm that there is no MEASUREMENT REPORT message from UE.

9

MEASUREMENT CONTROL

IE "measurement validity" is set to "All But CELL_DCH".

10

SS waits for 8 seconds to confirm that there is no MEASUREMENT REPORT message from UE.

11

RADIO BEARER RECONFIGURATION

12

RADIO BEARER RECONFIGURATION COMPLETE

While entering in CELL_FACH state from CELL_DCH state UE shall start traffic volume measurement setup by MEASUREMENT CONTROL message (Step 9).

13

MEASUREMENT REPORT

14

MEASUREMENT CONTROL

UE shall release measurement context setup by MEASUREMENT CONTROL message (Step 9).

15

RADIO BEARER RECONFIGURATION

16

RADIO BEARER RECONFIGURATION COMPLETE

UE is in CELL_DCH state.

17

MEASUREMENT CONTROL

IE "measurement validity" is set to "CELL_DCH".

18

MEASUREMENT REPORT

19

RADIO BEARER RECONFIGURATION

20

RADIO BEARER RECONFIGURATION COMPLETE

While entering in CELL_FACH state from CELL_DCH state UE shall stop traffic volume measurement setup by MEASUREMENT CONTROL message (Step 17).

21

SS waits for 8 seconds to confirm that there is no MEASUREMENT REPORT message from UE.

22

MEASUREMENT CONTROL

UE shall release measurement context setup by MEASUREMENT CONTROL message (Step 17)

23

RADIO BEARER RECONFIGURATION

24

RADIO BEARER RECONFIGURATION COMPLETE

UE is in CELL_DCH state.

25

MEASUREMENT CONTROL

IE "measurement validity" is set to "All states".

26

MEASUREMENT REPORT

27

RADIO BEARER RECONFIGURATION

28

RADIO BEARER RECONFIGURATION COMPLETE

While entering in CELL_FACH state from CELL_DCH state UE shall continue traffic volume measurement setup by MEASUREMENT CONTROL message (Step 25).

29

MEASUREMENT REPORT

30

MEASUREMENT CONTROL

UE shall release measurement context setup by MEASUREMENT CONTROL message (Step 25)

31

RADIO BEARER RECONFIGURATION

32

RADIO BEARER RECONFIGURATION COMPLETE

UE is in CELL_DCH state.

33

SIB12 modified

Traffic volume measurements and reporting is assigned to UEs

34

RADIO BEARER RECONFIGURATION

35

RADIO BEARER RECONFIGURATION COMPLETE

While entering in CELL_FACH state from CELL_DCH state UE shall start traffic volume measurement as assigned in System Information (Step 33).

36

MEASUREMENT REPORT

37

MEASUREMENT CONTROL

UE shall release measurement context assigned in System Information (Step 33).

Specific Message Content

System Information Block type 1 (FDD or 1.28Mcps TDD)

Use the default system information block with the same type specified in clause 6.1 of TS 34.108, with the following exceptions:

Information Element

Value/remark

– UE Timers and constants in connected mode

– T312

2

MEASUREMENT CONTROL (Step 1)

Information Element

Value/remark

Measurement Identity

1

Measurement Command

Setup

– CHOICE measurement type

Traffic Volume Measurement

– Traffic volume measurement object list

Not Present

– Traffic volume measurement quantity

RLC Buffer Payload

– Traffic volume reporting quantity

– RB buffer payload

True

– RB buffer payload average

False

– RB buffer payload variance

False

– Measurement validity

Not Present

– Report criteria

Periodical Reporting Criteria

– Reporting amount

8

– Reporting interval

8 Sec

Measurement reporting mode

– Transfer Mode

Acknowledged mode

– Periodical or event trigger

Periodic

Additional measurement list

Not Present

DPCH compressed mode status

Not Present

MEASUREMENT REPORT (Step 2)

The order in which the RBs are reported is not checked.

Information Element

Value/remark

Measurement identity

1

Measured Results

– CHOICE measurement

Traffic volume measured results list

– Traffic volume measurement results

– RB identity

1

– RLC buffer payload

Check to see if this IE is present

– RLC buffer payload average

Check to see if this IE is absent

– RLC buffer payload variance

Check to see if this IE is absent

– RB identity

2

– RLC buffer payload

Check to see if this IE is present

– RLC buffer payload average

Check to see if this IE is absent

– RLC buffer payload variance

Check to see if this IE is absent

– RB identity

3

– RLC buffer payload

Check to see if this IE is present

– RLC buffer payload average

Check to see if this IE is absent

– RLC buffer payload variance

Check to see if this IE is absent

– RB identity

4

– RLC buffer payload

Check to see if this IE is present

– RLC buffer payload average

Check to see if this IE is absent

– RLC buffer payload variance

Check to see if this IE is absent

– RB identity

20

– RLC buffer payload

Check to see if this IE is present

– RLC buffer payload average

Check to see if this IE is absent

– RLC buffer payload variance

Check to see if this IE is absent

Measured results on RACH

Check to see if this IE is absent

Additional measured results

Check to see if this IE is absent

Event results

Check to see if this IE is absent

RADIO BEARER RECONFIGURATION (Step 3, 11, 19, 27, and 34)

Use the same message type found in TS 34.108 clause 9 with condition set to A5.

RADIO BEARER RECONFIGURATION (Step 6, 15, 23, and 31)

Use the same message type found in TS 34.108 clause 9 with condition set to A4.

MEASUREMENT CONTROL (Step 9)

The contents of this message are identical to MEASUREMENT CONTROL (Step 1) message with the following exceptions:

Information Element

Value/remark

Measurement Identity

2

Measurement Command

Setup

– CHOICE measurement type

Traffic Volume Measurement

– Measurement validity

All But CELL_DCH

MEASUREMENT REPORT (Step 13)

The contents of this message are identical to MEASUREMENT REPORT (Step 2) message with the following exceptions:

Information Element

Value/Remarks

Measurement identity

2

MEASUREMENT CONTROL (Step 14)

Information Element

Value/remark

Measurement Identity

2

Measurement Command

Release

Measurement reporting mode

Not Present

Additional measurement list

Not Present

DPCH compressed mode status

Not Present

MEASUREMENT CONTROL (Step 17)

The contents of this message are identical to MEASUREMENT CONTROL (Step 1) message with the following exceptions:

Information Element

Value/remark

Measurement Identity

3

Measurement Command

Setup

– CHOICE measurement type

Traffic Volume Measurement

– Measurement validity

CELL_DCH

MEASUREMENT REPORT (Step 18)

The contents of this message are identical to MEASUREMENT REPORT (Step 2) message with the following exceptions:

Information Element

Value/Remarks

Measurement identity

3

MEASUREMENT CONTROL (Step 22)

The contents of this message are identical to MEASUREMENT CONTROL (Step 14) message with the following exceptions:

Information Element

Value/Remark

Measurement Identity

3

MEASUREMENT CONTROL (Step 25)

The contents of this message are identical to MEASUREMENT CONTROL (Step 1) message with the following exceptions:

Information Element

Value/remark

Measurement Identity

4

Measurement Command

Setup

– CHOICE measurement type

Traffic Volume Measurement

– Traffic volume measurement object list

– UL transport channel identity

RACH

– UL transport channel identity

DCH :1

– UL transport channel identity

DCH : 5

– Measurement validity

All States

MEASUREMENT REPORT (Step 26, and 29)

The contents of this message are identical to MEASUREMENT REPORT (Step 2) message with the following exceptions:

Information Element

Value/Remarks

Measurement identity

4

MEASUREMENT CONTROL (Step 30)

The contents of this message are identical to MEASUREMENT CONTROL (Step 14) message with the following exceptions:

Information Element

Value/Remark

Measurement Identity

4

System Information Block type 12 (Step 33) (FDD)

Information Element

Value/remark

FACH measurement occasion info

Not Present

Measurement control system information

– Use of HCS

Not used

– Cell_selection_and_reselection_quality

CPICH RSCP

– Intra-frequency measurement system information

– Intra-frequency measurement identity

1

– Intra-frequency cell info list

– CHOICE intra-frequency cell removal

Remove no intra-frequency cells

– New intra-frequency cells

– Intra-frequency cell id

1

– Cell info

– Cell individual offset

0 dB

– Reference time difference to cell

Not Present

– Read SFN indicator

TRUE

– CHOICE mode

FDD

– Primary CPICH info

– Primary scrambling code

Set to same code as used for cell 1

– Primary CPICH Tx power

Not Present

– TX Diversity indicator

FALSE

– Cell selection and re-selection info for SIB11/12

– Qoffset1s,n

0dB

– Qoffset1s,n

Not present

– Maximum allowed UL Tx Power

Reference to table 6.1.1

– HCS neighbouring cell information

Not Present

– CHOICE mode

FDD

– Qqualmin

Reference to table 6.1.1

– Qrxlevmin

Reference to table 6.1.1

– Intra-frequency measurement quantity

Not Present

– Intra-frequency reporting quantity for RACH reporting

Not Present

– Maximum number of reported cells on RACH

Not Present

– Reporting information for state CELL_DCH

Not Present

– Inter-frequency measurement system information

Not Present

– Inter-RAT measurement system information

Not Present

– Traffic volume measurement system information

– Traffic volume measurement ID

5

– Traffic volume measurement object list

Not Present

– Traffic volume measurement quantity

RLC Buffer Payload

– Traffic volume reporting quantity

– RB buffer payload

True

– RB buffer payload average

False

– RB buffer payload variance

False

– Traffic volume measurement reporting criteria

Not Present

– Measurement validity

Not Present

– Measurement reporting mode

– Measurement report transfer mode

Acknowledged Mode

– Periodical or event trigger

Periodical

– Report criteria system Information

Periodical reporting criteria

– Reporting amount

Infinity

– Reporting interval

8 seconds

System Information Block type 12 (Step 33) (TDD)

Information Element

Value/remark

FACH measurement occasion info

Not Present

Measurement control system information

– Use of HCS

Not used

– Intra-frequency measurement system information

– Intra-frequency measurement identity

Not Present

– Intra-frequency cell info list

– CHOICE intra-frequency cell removal

Remove no intra-frequency cells

– New intra-frequency cells

– Intra-frequency cell id

1

– Cell info

– Cell individual offset

0 dB

– Reference time difference to cell

Not Present

– Read SFN indicator

TRUE

– CHOICE mode

TDD

– Primary CCPCH info

Set to same as used for cell 1

– TX Diversity indicator

FALSE

– Cell selection and re-selection info for SIB11/12

– Qoffset1s,n

0dB

– Qoffset1s,n

Not present

– Maximum allowed UL Tx Power

Reference to table 6.1.1

– HCS neighbouring cell information

Not Present

– CHOICE mode

TDD

– Qrxlevmin

Reference to table 6.1.1

– Cells for measurement

Not Present

– Intra-frequency measurement quantity

Not Present

– Intra-frequency reporting quantity for RACH reporting

Not Present

– Maximum number of reported cells on RACH

Not Present

– Reporting information for state CELL_DCH

Not Present

– Inter-frequency measurement system information

Not Present

– Inter-RAT measurement system information

Not Present

– Traffic volume measurement system information

– Traffic volume measurement ID

5

– Traffic volume measurement object list

Not Present

– Traffic volume measurement quantity

RLC Buffer Payload

– Traffic volume reporting quantity

– RB buffer payload

TRUE

– RB buffer payload average

FALSE

– RB buffer payload variance

FALSE

– Traffic volume measurement reporting criteria

Not Present

– Measurement validity

Not Present

– Measurement reporting mode

– Measurement report transfer mode

Acknowledged Mode

– Periodical or event trigger

Periodical

– Report criteria system Information

Periodical reporting criteria

– Reporting amount

Infinity

– Reporting interval

8 seconds

MEASUREMENT REPORT (Step 36)

The contents of this message are identical to MEASUREMENT REPORT (Step 2) message with the following exceptions:

Information Element

Value/Remarks

Measurement identity

5

MEASUREMENT CONTROL (Step 37)

The contents of this message are identical to MEASUREMENT CONTROL (Step 14) message with the following exceptions:

Information Element

Value/Remark

Measurement Identity

5

8.4.1.19.5 Test Requirement

The UE shall send MEASUREMENT REPORT message in steps 13, 29 and 36. The UE shall not send MEASUREMENT REPORT message in steps 5, 8, and 21.

8.4.1.20 Void

8.4.1.21 Void

8.4.1.22 Measurement Control and Report: Quality measurements

8.4.1.22.1 Definition

8.4.1.22.2 Conformance requirement

Upon reception of a MEASUREMENT CONTROL message the UE shall perform actions specified in TS 25.331 subclause 8.6 unless otherwise specified below.

The UE shall:

1> read the IE "Measurement command";

1> if the IE "Measurement command" has the value "setup":

2> store this measurement in the variable MEASUREMENT_IDENTITY according to the IE "measurement identity", first releasing any previously stored measurement with that identity if that exists;

2> for measurement types "inter-RAT measurement" or "inter-frequency measurement":

2> for measurement type "UE positioning measurement":

2> for any other measurement type:

3> if the measurement is valid in the current RRC state of the UE:

4> begin measurements according to the stored control information for this measurement identity.

Reference

3GPP TS 25.331 clause 8.4.1.3

8.4.1.22.3 Test Purpose

1. To confirm that the UE performs quality measurement as specified in MEASUREMENT CONTROL message received. In CELL_DCH state, the UE shall send MEASUREMENT REPORT message when the reporting criteria is fulfilled for any ongoing quality measurement.

8.4.1.22.4 Method of test

Initial Condition

System Simulator: 1 cell

UE: CS-DCCH+DTCH_DCH (State 6-9) or PS-DCCH+DTCH_DCH (State 6-10) as specified in clause 7.4 of TS 34.108, depending on the CN domain(s) supported by the UE.

Test Procedure

The UE is in CELL_DCH state. MEASUREMENT CONTROL message is sent to UE to assign quality measurement and reporting. As assigned in MEASUREMENT CONTROL message, the UE shall periodically send MEASUREMENT REPORT message reporting BLER of downlink transport channel(s). SS calls for generic procedure C.3 to check that UE is in CELL_DCH state.

Expected Sequence

Step

Direction

Message

Comment

UE

SS

1

MEASUREMENT CONTROL

The UE is requested to perform "Quality measurements"

2

MEASUREMENT REPORT

3

MEASUREMENT REPORT

UE shall send second MEASUREMENT REPORT message after 64 seconds.

4



CALL C.3

If the test result of C.3 indicates that UE is in CELL_DCH state, the test passes, otherwise it fails.

Specific Message Content

MEASUREMENT CONTROL (Step 1) (FDD)

Information Element

Value/remark

Measurement identity

16

Measurement command

Setup

Measurement reporting mode

– Measurement Report Transfer Mode

Acknowledged mode RLC

– Periodical Reporting / Event Trigger Reporting Mode

Periodical reporting

Additional measurement list

Not Present

– CHOICE measurement type

Quality measurement

– Quality reporting quantity

– DL transport channel BLER

True

– Transport channels for BLER reporting

Not present

– CHOICE mode

FDD

– CHOICE report criteria

Periodical reporting criteria

– Reporting amount

Infinity

– Reporting interval

64 sec

DPCH compressed mode status

Not Present

MEASUREMENT CONTROL (Step 1) (1.28 Mcps TDD)

Information Element

Value/remark

Measurement identity

16

Measurement command

Setup

– CHOICE measurement type

Quality measurement

– Quality reporting quantity

– DL transport channel BLER

True

– Transport channels for BLER reporting

Not present

– CHOICE mode

TDD

– SIR measurement list

– TFCS ID

Not present

– CHOICE Reporting criteria

Periodical reporting criteria

– Reporting amount

Infinity

– Reporting interval

64 sec

Measurement reporting mode

– Transfer Mode

Acknowledged mode

– Periodical or event trigger

Periodic

Additional measurement list

Not Present

DPCH compressed mode status

Not Present

MEASUREMENT REPORT (Step 2,3) (FDD)

In case of CS speech call,

Information Element

Value/remark

Measurement identity

16

Measured Results

– CHOICE measurement

Quality measurement

– BLER measurement results list

– Transport channel identity

6

– DL transport channel BLER

Check to see if this IE is present

– Transport channel identity

7

– DL transport channel BLER

Check to see if this IE is present

– Transport channel identity

8

– DL transport channel BLER

Check to see if this IE is present

– Transport channel identity

10

– DL transport channel BLER

Check to see if this IE is present

– CHOICE mode

FDD

Measured results on RACH

Check to see if this IE is absent

Additional measured results

Check to see if this IE is absent

Event results

Check to see if this IE is absent

MEASUREMENT REPORT (Step 2,3) (1.28 Mcps TDD)

Information Element

Value/remark

Measurement identity

16

Measured Results

– CHOICE measurement

Quality measurement

– BLER measurement results list

– DL Transport channel identity

10

– DL transport channel BLER

Check to see if this IE is present

– CHOICE Mode

TDD

– SIR measurement results

Check to see if this IE is absent

Measured results on RACH

Check to see if this IE is absent

Additional measured results

Check to see if this IE is absent

Event results

Check to see if this IE is absent

In any cases except CS speech call:

Information Element

Value/remark

Measurement identity

16

Measured Results

– CHOICE measurement

Quality measurement

– BLER measurement results list

– Transport channel identity

6

– DL transport channel BLER

Check to see if this IE is present

– Transport channel identity

10

– DL transport channel BLER

Check to see if this IE is present

– CHOICE mode

FDD

Measured results on RACH

Check to see if this IE is absent

Additional measured results

Check to see if this IE is absent

Event results

Check to see if this IE is absent

8.4.1.22.5 Test Requirement

In step 2 and 3, the UE shall send MEASUREMENT REPORT message to report BLER for downlink DCH transport channel.

8.4.1.23 Measurement Control and Report: Intra-frequency measurement for events 1C and 1D

8.4.1.23.1 Definition

8.4.1.23.2 Conformance requirement

1. When event 1C is configured in the UE, the UE shall:

1> if "Measurement quantity" is "pathloss" and Equation 1 below is fulfilled for one or more primary CPICHs, or if "Measurement quantity" is "CPICH Ec/N0" or "CPICH RSCP", and Equation 2 below is fulfilled for one or more primary CPICHs, for each of these primary CPICHs:

2> if all required reporting quantities are available for that cell; and

2> if the equations have been fulfilled for a time period indicated by "Time to trigger", and if the primary CPICH that is better is not included in the active set but the other primary CPICH is any of the primary CPICHs included in the active set, and if that first primary CPICH is not included in the "cells triggered" in the variable TRIGGERED_1C_EVENT:

3> include that primary CPICH in the "cells recently triggered" in the variable TRIGGERED_1C_EVENT.

1> if the value of "Replacement activation threshold" for this event is less than or equal to the current number of cells in the active set or equal to 0 and if any primary CPICHs are stored in the "cells recently triggered" in the variable TRIGGERED_1C_EVENT:

2> if "Reporting interval" for this event is not equal to 0:

3> if the IE "Periodical reporting running" in the variable TRIGGERED_1C_EVENT is set to FALSE:

4> start a timer for with the value of "Reporting interval" for this event and set the IE "Periodical reporting running" in the variable TRIGGERED_1C_EVENT to TRUE.

3> set "sent reports" for that primary CPICH in the variable TRIGGERED_1C_EVENT to 1.

2> send a measurement report with IEs set as below:

3> set in "intra-frequency measurement event results": "Intrafrequency event identity" to "1c"; and

3> include in "cell measurement event results" all entries of the "cells recently triggered" in the variable TRIGGERED_1C_EVENT not in the active set as well as the "primary CPICH info" of all the primary CPICHs in the active set for which the measured value is worse (i.e. greater for pathloss and less for the other measurement quantities) than the one of the entry in "cell recently triggered" that has the best measured value. The "primary CPICH info" for those cells shall be ordered according to their measured value taking into account their cell individual offset, beginning with the best cell to the worst one;

3> set the IE "measured results" and the IE "additional measured results" according to subclause 8.4.2, not taking into account the cell individual offset for each cell.

2> ….

2. This section applies to R99 & Rel-4 releases:

When an intra-frequency measurement configuring event 1d is set up, the UE shall:

1> create a variable TRIGGERED_1D_EVENT related to that measurement, which shall initially contain the best cell in the active set when the measurement is initiated;

1> delete this variable when the measurement is released.

When event 1D is configured in the UE, the UE shall:

1> if "Measurement quantity" is "pathloss" and Equation 1 below is fulfilled for a primary CPICH that is not stored in "Best cell" in variable BEST_CELL_1D_EVENT, or if "Measurement quantity" is "CPICH Ec/N0" or "CPICH RSCP", and Equation 2 below is fulfilled for a primary CPICH that is not stored in "Best cell" in variable BEST_CELL_1D_EVENT:

NOTE: If the equations are simultaneously fulfilled for more than one primary CPICH, the UE should report only one event 1D, triggered by the best primary CPICH.

2> if all required reporting quantities are available for that cell, and if the equations have been fulfilled for a time period indicated by "Time to trigger":

3> set "best cell" in the variable BEST_CELL_1D_EVENT to that primary CPICH that triggered the event;

3> send a measurement report with IEs set as below:

4> set in "intra-frequency measurement event results"; "Intrafrequency event identity" to "1d" and "cell measurement event results" to the CPICH info of the primary CPICH that triggered the report, not taking into account the cell individual offset for each cell.

4> set the IE "measured results" and the IE "additional measured results" according to subclause 8.4.2, not taking into account the cell individual offset for each cell.

NOTE: Event 1D can be triggered by an active or by a non-active CPICH.

3. This section applies from Rel-5 releases onwards:

When an intra-frequency measurement configuring event 1d is set up, the UE shall:

1> create a variable TRIGGERED_1D_EVENT related to that measurement, which shall initially contain the best cell in the active set when the measurement is initiated;

1> delete this variable when the measurement is released.

1> As soon as the best cell in the active set has been evaluated by the UE (and stored in the TRIGGERED_1D_EVENT variable) and provided that there is more than one cell in the active set, trigger an immediate measurement report with IEs set as below:

2> set in "intra-frequency measurement event results"; "Intrafrequency event identity" to "1d" and "cell measurement event results" to the CPICH info of the primary CPICH stored in the TRIGGERED_1D_EVENT variable;

2> set the IE "measured results" and the IE "additional measured results" according to subclause 8.4.2

When event 1D is configured in the UE, the UE shall:

1> if IE "useCIO" is present and its value is TRUE, take into account the Cell Individual Offset for evaluation of the Equation 1 and 2, otherwise do not take it into account.

1> if "Measurement quantity" is "pathloss" and Equation 1 below is fulfilled for a primary CPICH that is not stored in "Best cell" in variable BEST_CELL_1D_EVENT, or if "Measurement quantity" is "CPICH Ec/N0" or "CPICH RSCP", and Equation 2 below is fulfilled for a primary CPICH that is not stored in "Best cell" in variable BEST_CELL_1D_EVENT:

NOTE: If the equations are simultaneously fulfilled for more than one primary CPICH, the UE should report only one event 1D, triggered by the best primary CPICH.

2> if all required reporting quantities are available for that cell, and if the equations have been fulfilled for a time period indicated by "Time to trigger" and if IE "Triggering condition 2" is absent or if it is present and that primary CPICH is part of cells allowed to trigger the event according to "Triggering condition 2":

3> set "best cell" in the variable BEST_CELL_1D_EVENT to that primary CPICH that triggered the event;

3> send a measurement report with IEs set as below:

4> set in "intra-frequency measurement event results"; "Intrafrequency event identity" to "1d" and "cell measurement event results" to the CPICH info of the primary CPICH that triggered the report.

4> set the IE "measured results" and the IE "additional measured results" according to subclause 8.4.2.

Reference

3GPP TS 25.331 clause 14.1.2.3, 14.1.2.4.

8.4.1.23.3 Test Purpose

1.A To confirm that the UE sends MEASUREMENT REPORT message if event 1C is configured, and number of cells in active set is greater than or equal to ‘Replacement activation threshold’ parameter, and if monitored or detected primary CPICH on same frequency becomes better than a primary CPICH in active set.

1.B To confirm that the UE does not send MEASUREMENT REPORT message indicating event 1C if number of cells in active set is less than ‘Replacement activation threshold’ parameter, and if monitored or detected primary CPICH on same frequency becomes better than a primary CPICH in active set.

1.C To confirm that the UE stops periodic reporting of event 1C if the cell that triggered event 1C is added into active set.

2.A To confirm that from Rel-5 onwards the UE sends a MEASUREMENT REPORT message as soon as event 1D is configured, when there is more than one cell in the active set.

2.B To confirm that the UE sends MEASUREMENT REPORT message if event 1D is configured and intra-frequency measurement indicates change in best cell.

8.4.1.23.4 Method of test

Initial Condition

System Simulator: 3 cells – The initial configurations of the 3 cells in the SS shall follow the values indicated in the column marked "T0" in table 8.4.1.23-1. The table is found in "Test Procedure" clause.

UE: CS-DCCH+DTCH_DCH (State 6-9) or PS-DCCH+DTCH_DCH (State 6-10) in cell 1 as specified in clause 7.4 of TS 34.108, depending on the CN domain supported by the UE.

Test Procedure

Table 8.4.1.23-1 illustrates the downlink power to be applied for the 3 cells at various time instants of the test execution. Column marked "T0" denotes the initial conditions, while columns marked "T1", "T2", “T3” and “T4” are to be applied subsequently. The exact instants on which these values shall be applied are described in the text in this clause.

Table 8.4.1.23-1

Parameter

Unit

Cell 1

Cell 2

Cell 3

T0

T1

T2

T3

T4

T0

T1

T2

T3

T4

T0

T1

T2

T3

T4

UTRA RF Channel Number

Mid Range Test Frequency

Mid Range Test Frequency

Mid Range Test Frequency

CPICH Ec

dBm

-60

-60

-60

-60

-66

-80

-60

-70

-70

OFF

-80

-60

OFF

-70

-60

The UE is initially in CELL_DCH state of cell 1 and has received the default broadcast information from SIB11/12 in Cell 1.

SS configures its downlink transmission power settings according to columns "T1" in table 8.4.1.23-1. UE shall be triggered to transmit a MEASUREMENT REPORT message, which includes the primary scrambling code for cell 2.

SS then performs a soft handover procedure by sending ACTIVE SET UPDATE message on the downlink DCCH. The UE shall reply with an ACTIVE SET UPDATE COMPLETE message on the uplink DCCH, and include cell 2 to the active set when the activation time specified has elapsed.

SS configures its downlink transmission power settings according to columns "T2" in table 8.4.1.23-1

SS then ask the UE to perform Intra-frequency measurement and report event 1C and event 1D. In MEASUREMENT CONTROL message, IE ‘Replacement activation threshold’ is set to 3 and IE ‘Cell individual offset’ is set to +6 dBm for Cell 3. From Rel-5 onwards the UE will send an initial measurement report containing the best cell due to event 1D configuration (R99 & Rel-4 UE releases shall not send a MESUREMENT REPORT). SS configures itself according to the values in columns "T3" shown above. Cell 3 becomes better than Cell 2 that is in active set of the UE, due to parameter ‘Cell Individual offset’ for Cell 3. However the UE shall not send MEASUREMENT REPORT message indicating event 1C because number of cells in active set is less than parameter ‘Replacement Activation Threshold’.

SS then sends MEASUREMENT CONTROL message to the UE to modify earlier configured intra-frequency measurement. Now, IE ‘Replacement activation threshold’ is set to 1. MEASUREMENT CONTROL message contains only those IEs that are modified and the UE shall continue to use current values of parameters that are not modified. The UE sends MEASUREMENT REPORT message reporting event 1C, monitored Cell 3 is better than Cell 2 that is in active set. The UE sends second MEASUREMENT REPORT message reporting event 1C after 4 seconds, equals to parameter ‘Reporting interval’.

SS then performs soft handover procedure by sending ACTIVE SET UPDATE message on the downlink DCCH. In this message SS commands UE to add Cell 3 and remove Cell 2 from active set. The UE shall reply with an ACTIVE SET UPDATE COMPLETE message. The UE shall also stop periodic reporting of event 1C because the Cell that triggered it is added into active set. SS then configures itself according to the values in columns "T4" shown above. This triggers event 1D and the UE sends MEASUREMENT REPORT message indicating Cell 3 as a best cell. SS calls for generic procedure C.3 to check that UE is in CELL_DCH state.

Expected Sequence

Step

Direction

Message

Comment

UE

SS

0

UE is initially in CELL_DCH state in cell 1.

0a

SS configures its downlink transmission power settings according to columns "T1" in table 8.4.1.23-1

0b

MEASUREMENT REPORT

See specific message contents for this message.

0c

SS configures its downlink transmission power settings according to columns "T2" in table 8.4.1.23-1

1

ACTIVE SET UPDATE

SS command the UE to add Cell 2 in active set.

2

ACTIVE SET UPDATE COMPLETE

3

MEASUREMENT CONTROL

Event 1C and 1D are configured. IE "Replacement activation threshold" is set to 3.

R99 & Rel-4 UE’s will go directly to step 4

3a

MEASUREMENT REPORT (Rel-5 onwards)

Event 1D is triggered. The UE shall report that Cell 1 is the best cell.

4

SS re-adjusts the downlink transmission power settings according to columns "T3" in table 8.4.1.23-1.

5

Check for 10 seconds, the UE shall not send MEASUREMENT REPORT message.

6

MEASUREMENT CONTROL

Measurement configured in step 3 is modified to set parameter ‘replacement activation threshold’ to 1.

7

MEASUREMENT REPORT

Event 1C is triggered. The UE shall report that Cell 3 is better than Cell 2. The report is received within 4 seconds (reporting interval)

8

MEASUREMENT REPORT

The UE shall send second report after 4 seconds (Reporting interval)

9

ACTIVE SET UPDATE

SS command the UE to replace Cell 2 in active set by Cell 3.

10

ACTIVE SET UPDATE COMPLETE

11

Check for 10 seconds, the UE shall not send MEASUREMENT REPORT message.

12

SS re-adjusts the downlink transmission power settings according to columns "T4" in table 8.4.1.23-1.

13

MEASUREMENT REPORT

The UE shall report event 1D change of best cell

14



CALL C.3

If the test result of C.3 indicates that UE is in CELL_DCH state, the test passes, otherwise it fails.

Specific Message Contents

All messages indicated below shall use the same content as described in default message content, with the following exceptions:

MEASUREMENT REPORT (Step 0b)

Information Element

Value/remark

Message Type

Integrity check info

– Message authentication code

This IE is checked to see if it is present. The value is compared against the XMAC-I value computed by SS. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I.

– RRC Message sequence number

This IE is checked to see if it is present. The value is used by SS to compute the XMAC-I value.

Measurement identity

1

Measured Results

– Intra-frequency measured results

Check to see if measurement results for 3 cells are included (the order in which the different cells are reported is not important)

– Cell measured results

– Cell Identity

Checked that this IE is absent

– Cell synchronisation information

Checked that this IE is absent

– Primary CPICH info

– Primary scrambling code

Refer to clause titled "Default settings for cell No.1 (FDD)" in clause 6.1 of TS 34.108

– CPICH Ec/N0

Checked that this IE is absent

– CPICH RSCP

Checked that this IE is present

– Pathloss

Checked that this IE is absent

– Cell measured results

– Cell Identity

Checked that this IE is absent

– Cell synchronisation information

Checked that this IE is present and includes IE COUNT-C-SFN frame difference

– Primary CPICH info

– Primary scrambling code

Refer to clause titled "Default settings for cell No.2 (FDD)" in clause 6.1 of TS 34.108

– CPICH Ec/N0

Checked that this IE is absent

– CPICH RSCP

Checked that this IE is present

– Pathloss

Checked that this IE is absent

– Cell measured results

– Cell Identity

Checked that this IE is absent

– Cell synchronisation information

Checked that this IE is present and includes IE COUNT-C-SFN frame difference

– Primary CPICH info

– Primary scrambling code

Refer to clause titled "Default settings for cell No.3 (FDD)" in clause 6.1 of TS 34.108

– CPICH Ec/N0

Checked that this IE is absent

– CPICH RSCP

Checked that this IE is present

– Pathloss

Checked that this IE is absent

Measured results on RACH

Checked that this IE is absent

Additional measured results

Checked that this IE is absent

Event results

– Intra-frequency measurement event results

– Intra-frequency event identity

1a

– Cell measurement event results

– Primary CPICH info

The UE may include either or both of the following cells.(the order in which the different cells are reported is not important)

– Primary scrambling code

Refer to clause titled "Default settings for cell No.2 (FDD)" in clause 6.1 of TS 34.108

– Primary scrambling code

Refer to clause titled "Default settings for cell No.3 (FDD)" in clause 6.1 of TS 34.108

ACTIVE SET UPDATE (Step 1)

Information Element

Value/remark

Version

Radio link addition information

– Primary CPICH Info

– Primary scrambling code

Primary scrambling code of Cell 2

– Downlink DPCH info for each RL

– CHOICE mode

FDD

– Primary CPICH usage for channel estimation

P-CPICH may be used.

– DPCH frame offset

Calculated value from Cell synchronisation information

– Secondary CPICH info

Not present

– DL channelisation code

This IE is repeated for all existing downlink DPCHs allocated to the UE

– Secondary scrambling code

1

– Spreading factor

Refer to the parameter set in TS 34.108

– Code number

For each DPCH, assign the same code number in the current code given in cell 1.

– Scrambling code change

Not present

– TPC combination index

0

– SSDT cell identity

Not present

R99 and Rel-4 only

– Close loop timing adjustment mode

Not present

– TFCI combining indicator

TRUE

– SCCPCH information for FACH

Not present

R99 and Rel-4 only

MEASUREMENT CONTROL (Step 3)

Information Element

Value/remark

Measurement identity

1

Measurement command

Setup

– CHOICE measurement type

Intra-frequency measurement

– Intra-frequency cell info list

– Intra-frequency cell removal

Remove no intra-frequency cells

– New intra-frequency info list

– Intra-frequency cell id

Id of Cell 3

– Cell info

– Cell individual offset

6 dBm

– Reference time difference to cell

Not present

– Read SFN indicator

FALSE

– CHOICE mode

FDD

– Primary CPICH Info

– Primary scrambling code

Primary scrambling code of Cell 3

– Primary CPICH TX power

Not present

– TX Diversity Indicator

FALSE

– Cell selection and Re-selection Info

Not Present

– Cell for measurement

– Intra-frequency cell id list

Set to id of cell 1, 2 and 3.

– Intra-frequency measurement quantity

– Filter Coefficient

0

– Measurement quantity

CPICH RSCP

– Intra-frequency reporting quantity

– Reporting quantities for active set cells

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CPICH Ec/No reporting indicator

FALSE

– CPICH RSCP reporting indicator

FALSE

– Pathloss reporting indicator

FALSE

– Reporting quantities for monitored set cells

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CPICH Ec/No reporting indicator

FALSE

– CPICH RSCP reporting indicator

FALSE

– Pathloss reporting indicator

FALSE

– Reporting quantities for detected cells

Not present

– Reporting cell status

Not present

– Measurement validity

Not present

– CHOICE report criteria

Intra-frequency measurement reporting criteria

– Parameters required for each events

– Intra-frequency event identity

1C

– Replacement activation threshold

3

– Reporting amount

16

– Reporting interval

4 seconds

– Hysteresis

4 (2dB)

– Time to trigger

10 mSec

– Reporting cell status

Not present

– Intra-frequency event identity

1D

– Hysteresis

4(2dB)

– Time to trigger

10 mSec

– Reporting cell status

Not present

Measurement reporting mode

– Measurement reporting transfer mode

Acknowledged mode RLC

– Periodic reporting / Event trigger reporting mode

Event trigger

Additional measurement list

Not present

DPCH compressed mode status info

Not present

MEASUREMENT REPORT (Step 3a)

Information Element

Value/remark

Measurement identity

1

Measured results

Check to see if this IE is absent

Measured results on RACH

Check to see if this IE is absent

Additional Measured results

Check to see if this IE is absent

Event results

Check to see if set to "Intra-frequency event results"

– Event ID

Check to see if set to "1D"

– Cell measurement event results

– Primary scrambling code

Check to see if set to "Primary scrambling code of Cell 1"

MEASUREMENT CONTROL (Step 6)

Information Element

Value/remark

Measurement identity

1

Measurement command

Modify

– CHOICE measurement type

Intra-frequency measurement

– Intra-frequency cell info list

Not present

– Intra-frequency measurement quantity

Not present

– Intra-frequency reporting quantity

Not present

– Reporting cell status

Not present

– Measurement validity

Not present

– CHOICE report criteria

Intra-frequency measurement reporting criteria

– Parameters required for each events

– Intra-frequency event identity

1C

– Replacement activation threshold

1

– Reporting amount

16

– Reporting interval

4 seconds

– Hysteresis

4 (2dB)

– Time to trigger

10 mSec

– Reporting cell status

Not present

– Intra-frequency event identity

1D

– Hysteresis

4(2dB)

– Time to trigger

10 mSec

– Reporting cell status

Not present

Measurement reporting mode

Not present

Additional measurement list

Not present

DPCH compressed mode status info

Not present

MEASUREMENT REPORT (Step 7 and 8)

Information Element

Value/remark

Measurement identity

1

Measured results

Check to see if this IE is absent

Measured results on RACH

Check to see if this IE is absent

Additional Measured results

Check to see if this IE is absent

Event results

Checked to see if set to "Intra Frequency Event results"

– Event ID

Check to see if set to "1C"

– Cell measurement event results

– Primary scrambling code

Check to see if set to Primary scrambling code of Cell 3

– Primary scrambling code

Check to see if set to Primary scrambling code of Cell 2

ACTIVE SET UPDATE (Step 9)

Information Element

Value/remark

Version

Radio link addition information

– Primary CPICH Info

– Primary scrambling code

Primary scrambling code of Cell 3

– Downlink DPCH info for each RL

– CHOICE mode

FDD

– Primary CPICH usage for channel estimation

P-CPICH may be used.

– DPCH frame offset

Calculated value from Cell synchronisation information

– Secondary CPICH info

Not present

– DL channelisation code

This IE is repeated for all existing downlink DPCHs allocated to the UE

– Secondary scrambling code

1

– Spreading factor

Refer to the parameter set in TS 34.108

– Code Number

For each DPCH, assign the same code number in the current code given in cell 1.

– Scrambling code change

No code change

– TPC Combination Index

0

– SSDT Cell Identity

Not present

R99 and Rel-4 only

– Close loop timing adjustment mode

Not present

– TFCI Combining Indicator

FALSE

– SCCPCH information for FACH

Not present

R99 and Rel-4 only

Radio link removal information

– Primary CPICH Info

– Primary scrambling code

Primary scrambling code of Cell 2

MEASUREMENT REPORT (Step 13)

Information Element

Value/remark

Measurement identity

1

Measured results

Check to see if this IE is absent

Measured results on RACH

Check to see if this IE is absent

Additional Measured results

Check to see if this IE is absent

Event results

Check to see if set to "Intra-frequency event results"

– Event ID

Check to see if set to "1D"

– Cell measurement event results

– Primary scrambling code

Check to see if set to "Primary scrambling code of Cell 3"

8.4.1.23.5 Test Requirement

2.A In step 3a a R99 or Rel-4 UE shall not send MEASUREMENT REPORT message, but a Rel-5 and onwards UE shall send a MEASUREMENT REPORT message indicating event 1D.

1.A In steps 7 and 8 the UE shall send MEASUREMENT REPORT message indicating event 1C. IE ‘Cell measurement event results’ in MEASUREMENT REPORT message shall contain primary scrambling code of Cell 3 and Cell 2 in that order.

1.B In step 5 the UE shall not send MEASUREMENT REPORT message.

1.C In step 11 the UE shall not send MEASUREMENT REPORT message.

2.B In step 13 the UE shall send MEASUREMENT REPORT message indicating event 1D. IE ‘Cell measurement event results’ in MEASUREMENT REPORT message shall contain primary scrambling code of Cell 3.

8.4.1.24 Measurement Control and Report: Inter-frequency measurement for event 2A

8.4.1.24.1 Definition

8.4.1.24.2 Conformance requirement

When event 2a is configured in the UE within a measurement, the UE shall:

1> when the measurement is initiated or resumed:

2> store the used frequency in the variable BEST_FREQUENCY_2A_EVENT.

1> if equation 1 below has been fulfilled for a time period indicated by "Time to trigger" for a frequency included for that event and which is not stored in the variable BEST_FREQUENCY_2A_EVENT:

2> send a measurement report with IEs set as below:

3> set in "inter-frequency measurement event results":

4> "inter-frequency event identity" to "2a"; and

4> "Frequency info" to the frequency that triggered the event; and

4> "Non frequency related measurement event results" to the "Primary CPICH info" of the best primary CPICH for FDD cells or "Primary CCPCH info" to the "Cells parameters ID" of the best primary CCPCH for TDD cells on that frequency, not taking into account the cell individual offset;

3> if a non-used frequency triggered the measurement report:

4> set the IE "measured results" and the IE "additional measured results" according to TS 25.331 subclause 8.4.2, not taking into account the cell individual offset;

3> if the used frequency triggered the measurement report:

4> do not include the IE "Inter-frequency measured results list" in the measurement report;

2> update the variable BEST_FREQUENCY_2A_EVENT with that frequency.

Equation 1:

The variables in the formula are defined as follows:

QNot Best is the quality estimate of a frequency not stored the "best frequency" in the variable BEST_FREQUENCY_2A_EVENT.

QBest is the quality estimate of the frequency stored in "best frequency" in the variable BEST_FREQUENCY_2A_EVENT.

H2a is the hysteresis parameter for the event 2a in that measurement.

Reference

3GPP TS 25.331 clause 14.2.1.1

8.4.1.24.3 Test Purpose

1.A To confirm that the UE sends MEASUREMENT REPORT message if event 2A is configured, and if any of the non- used frequencies quality estimate becomes better than the currently used frequency quality estimate.

1.B To confirm that the UE does not send MEASUREMENT REPORT message indicating event 2A if hysteresis condition is not fulfilled.

1.C To confirm that the UE does not send MEASUREMENT REPORT message indicating event 2A if time to trigger condition is not fulfilled.

8.4.1.24.4 Method of test

Initial Condition

System Simulator: 2 cells – The initial configurations of the 2 cells in the SS shall follow the values indicated in the column marked "T0" in table 8.4.1.24-1. The table is found in "Test Procedure" clause.

UE: CS-DCCH+DTCH_DCH (State 6-9) or PS-DCCH+DTCH_DCH (State 6-10) in cell 1 as specified in clause 7.4 of TS 34.108, depending on the CN domain supported by the UE.

Related ICS/IXIT statements

– Compressed mode required yes/no

Test Procedure

Table 8.4.1.24-1 illustrates the downlink power to be applied for the 2 cells at various time instants of the test execution. Column marked "T0" denotes the initial conditions, while columns marked "T1", "T2", "T3", "T4" and "T5" are to be applied subsequently. The exact instants on which these values shall be applied are described in the text in this clause.

Table 8.4.1.24-1

Parameter

Unit

Cell 1

Cell 4

T0

T1

T2

T3

T4

T5

T0

T1

T2

T3

T4

T5

UTRA RF Channel Number

Mid Range Test Frequency

High Range Test Frequency

CPICH Ec (FDD)

dBm/
3.84 Mhz

-65

-63

-65

-70

-65

-70

-75

-60

-75

-55

-75

-55

P-CCPCH RSCP (TDD)

dBm

-65

-63

-65

-70

-65

-70

-75

-60

-75

-55

-75

-55

P-CCPCH TS (3.84Mcps TDD and 7.68Mcps TDD)

TS 0

TS 4

The UE is initially in CELL_DCH state of cell 1. SS commands the UE to perform measurements of transmitted power using MEASUREMENT CONTROL message. This measurement is setup to confirm that while sending MEASUREMENT REPORT message, the UE sets IE "Additional measured results" correctly. If UE requires compressed mode (for FDD only), SS performs PHYSICAL CHANNEL RECONFIGURATION procedure to activate compressed mode. SS then commands the UE to perform Inter-frequency measurements and report event 2A by sending MEASUREMENT CONTROL message. In MEASUREMENT CONTROL message, IE "Hysteresis" is set to 14.5 dB and IE "Additional measurement list" is set to id of "UE Internal measurements" configured earlier. SS then configures itself according to the values in columns "T1" shown above. Even though quality estimate for Cell 4 has become better than that of Cell 1, event 2A will not be triggered since hysteresis condition is not fulfilled. SS then configures itself according to the values in columns "T2" shown above.

SS sends MEASUREMENT CONTROL message to modify parameter "Hysteresis" of Inter-frequency measurements to 1 dB. SS then configures Cell 1 and Cell 4 according to columns "T3" for short duration (less than 5 seconds), and then configures itself according to columns "T4" shown above. The UE will not send MEASUREMENT REPORT message because time to trigger condition is not fulfilled. SS then configures itself according to the values in columns "T5" shown above. The UE sends MEASUREMENT REPORT message reporting even 2A as well as measurement of transmitted power.

SS calls for generic procedure C.3 to check that UE is in CELL_DCH state.

Important Note: Duration between time instant "T3" and "T4" (between steps 9 and 10 of expected sequence) must be less than 5 seconds.

Expected Sequence

Step

Direction

Message

Comment

UE

SS

1

MEASUREMENT CONTROL

To setup UE Internal measurement.

If Compressed Mode not required (refer ICS/IXIT) go to step 4

2

PHYSICAL CHANNEL RECONFIGURATION

SS instructs UE to begin compressed mode operation.

(for FDD only)

3

PHYSICAL CHANNEL RECONFIGURATION COMPLETE

(for FDD only)

4

MEASUREMENT CONTROL

SS commands the UE to perform Inter-frequency measurements and to report event 2A.

5

SS re-adjusts the downlink transmission power settings according to columns "T1" in table 8.4.1.24-1.

6

Check for 10 seconds, the UE shall not send MEASUREMENT REPORT message, as hysteresis condition is not fulfilled.

7

SS re-adjusts the downlink transmission power settings according to columns "T2" in table 8.4.1.24-1.

8

MEASUREMENT CONTROL

Modify hysteresis parameter for event 2A.

9

SS re-adjusts the downlink transmission power settings according to columns "T3" in table 8.4.1.24-1.

10

SS re-adjusts the downlink transmission power settings according to columns "T4" in table 8.4.1.24-1. This step should be completed within 5 seconds after completing step 9.

11

Check for 10 seconds, the UE shall not send MEASUREMENT REPORT message, as time to trigger condition is not fulfilled.

12

SS re-adjusts the downlink transmission power settings according to columns "T5" in table 8.4.1.24-1.

13

MEASUREMENT REPORT

This message should come at least 5 seconds later after changing power setting of Cell 4.

14



CALL C.3

If the test result of C.3 indicates that UE is in CELL_DCH state, the test passes, otherwise it fails.

Specific Message Contents

All messages indicated below shall use the same content as described in default message content, with the following exceptions:

MEASUREMENT CONTROL (Step 1) (FDD)

Information Element

Value/remark

Measurement identity

1

Measurement command

Setup

CHOICE measurement type

UE internal measurement

– UE internal measurement quantity

– Measurement quantity

UE transmitted power

– Filter Coefficient

4

– UE internal reporting quantity

– UE Transmitted Power

TRUE

– CHOICE mode

FDD

– UE Rx-Tx time difference

FALSE

– CHOICE report criteria

No reporting

Measurement reporting mode

– Measurement Report Transfer Mode

Acknowledged mode RLC

– Periodical Reporting / Event Trigger Reporting Mode

Event Trigger Reporting Mode

Additional measurements list

Not present

DPCH compressed mode status

Not present

MEASUREMENT CONTROL (Step 1) (1.28 Mcps TDD)

Information Element

Value/remark

Measurement identity

1

Measurement command

Setup

CHOICE measurement type

UE internal measurement

– UE internal measurement quantity

– Measurement quantity

UE transmitted power

– Filter Coefficient

4

– UE internal reporting quantity

– UE Transmitted Power

TRUE

– CHOICE mode

TDD

-CHOICE TDD option

1.28 Mcps TDD

– TADV info

FALSE

– CHOICE report criteria

No reporting

Measurement reporting mode

– Measurement Report Transfer Mode

Acknowledged mode RLC

– Periodical Reporting / Event Trigger Reporting Mode

Event Trigger Reporting Mode

Additional measurements list

Not present

DPCH compressed mode status

Not present

MEASUREMENT CONTROL (Step 1) (3.84 Mcps TDD)

Information Element

Value/remark

Measurement identity

1

Measurement command

Setup

CHOICE measurement type

UE internal measurement

– UE internal measurement quantity

– Measurement quantity

UE transmitted power

– Filter Coefficient

4

– UE internal reporting quantity

– UE Transmitted Power

TRUE

– CHOICE mode

TDD

-CHOICE TDD option

3.84 Mcps TDD

– Applied TA

FALSE

– CHOICE report criteria

No reporting

Measurement reporting mode

– Measurement Report Transfer Mode

Acknowledged mode RLC

– Periodical Reporting / Event Trigger Reporting Mode

Event Trigger Reporting Mode

Additional measurements list

Not present

DPCH compressed mode status

Not present

MEASUREMENT CONTROL (Step 1) (7.68 Mcps TDD)

Information Element

Value/remark

Measurement identity

1

Measurement command

Setup

CHOICE measurement type

UE internal measurement

– UE internal measurement quantity

– Measurement quantity

UE transmitted power

– Filter Coefficient

4

– UE internal reporting quantity

– UE Transmitted Power

TRUE

– CHOICE mode

TDD

-CHOICE TDD option

7.68 Mcps TDD

– Applied TA

FALSE

– CHOICE report criteria

No reporting

Measurement reporting mode

– Measurement Report Transfer Mode

Acknowledged mode RLC

– Periodical Reporting / Event Trigger Reporting Mode

Event Trigger Reporting Mode

Additional measurements list

Not present

DPCH compressed mode status

Not present

PHYSICAL CHANNEL RECONFIGURATION (Step 2) (FDD)

Use the same message sub-type found in clause 9 of TS 34.108, which is entitled "(Packet to CELL_DCH from CELL_DCH in PS)FDD", with the following exceptions in the IE(s) concerned:

Information Element

Value/remark

Version

Downlink information common for all radio links

– Downlink DPCH info common for all RL

– Timing Indication

Maintain

– Downlink DPCH power control information

– DPC mode

0 (Single)

– CHOICE Mode

FDD

– Power offset PPilot-DPDCH

0

– DL rate matching restriction information

Not present

– Spreading factor

Refer to the parameter set in TS 34.108

– Fixed or flexible position

Flexible

– TFCI existence

TRUE

– Number of bits for Pilot bits (SF=128, 256)

Not present

– DPCH compressed mode info

– TGPSI

1

– TGPS status flag

Activate

– TGCFN

(Current CFN+(256 – TTI/10msec)) mod 256

– Transmission gap pattern sequence configuration parameters

– TGMP

FDD Measurement

– TGPRC

Infinity

– TGSN

4

– TGL1

7

– TGL2

Not Present

– TGD

Undefined

– TGPL1

3

– TGPL2

Not Present

R99 and REL-4 only

– RPP

Mode 0

– ITP

Mode 0

– CHOICE UL/DL mode

UL and DL or DL only or UL only depending on UE capability

– Downlink compressed mode method

SF/2

– Uplink compressed mode method

SF/2 or Not present depending on UE capability

– Downlink frame type

B

– DeltaSIR1

20 (2.0)

– DeltaSIRAfter1

10 (1.0)

– DeltaSIR2

Not present

– DeltaSIRAfter2

Not present

– N identify abort

Not present

– T Reconfirm abort

Not present

– TX diversity mode

None

– SSDT information

Not present

R99 and Rel-4 only

– Default DPCH offset value

Not present

MEASUREMENT CONTROL (Step 4) (FDD)

Information Element

Value/remark

Measurement identity

2

Measurement command

Setup

– CHOICE measurement type

Inter-frequency measurement

– Inter-frequency cell info list

– Inter-frequency cell removal

Not present

– New inter-frequency info list

– Inter-frequency cell id

Id of Cell 4

– Frequency Information

Frequency of Cell 4

– Cell info

– Cell individual offset

Not present

– Reference time difference to cell

Not present

– CHOICE mode

FDD

– Read SFN Indicator

FALSE

– Primary CPICH Info

– Primary scrambling code

Primary scrambling code of Cell 4

– Primary CPICH TX power

Not present

– TX Diversity Indicator

FALSE

– Cell for measurement

Not present

– Inter-frequency measurement quantity

– Filter Coefficient

0

– Frequency quality estimate quantity

CPICH RSCP

– Inter-frequency reporting quantity

– UTRAN carrier RSSI

FALSE

– Frequency quality estimate

FALSE

– Non frequency related quantities

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CPICH Ec/No reporting indicator

FALSE

– CPICH RSCP reporting indicator

FALSE

– Pathloss reporting indicator

FALSE

– Measurement validity

CELL_DCH state

– Inter-frequency SET UPDATE

– UE autonomous update mode

On with no reporting

– CHOICE report criteria

Inter-frequency measurement reporting criteria

– Parameters required for each events

– Inter-frequency event identity

2A

– Used frequency threshold

Not present

– Used frequency W

0

– Hysteresis

29 (14.5 dB)

– Time to trigger

5000 mSec

– Reporting cell status

Not present

– Non-used frequency parameter list

– Non-used frequency threshold

-72 dBm

– Non-used frequency W

0

Measurement reporting mode

– Measurement reporting transfer mode

Acknowledged mode RLC

– Periodic reporting / Event trigger reporting mode

Event trigger

Additional measurement list

– Measurement identity

1

DPCH compressed mode status info

Not present

MEASUREMENT CONTROL (Step 4) (1.28 Mcps TDD)

Information Element

Value/remark

Measurement identity

2

Measurement command

Setup

– CHOICE measurement type

Inter-frequency measurement

– Inter-frequency measurement objects list

– Inter-frequency cell removal

Not present

– New inter-frequency cells

– Inter-frequency cell id

Id of Cell 4

– Frequency Info

Frequency of Cell 4

– Cell info

– Cell individual offset

Not present

– Reference time difference to cell

Not present

– Read SFN Indicator

FALSE

– CHOICE mode

TDD

– Primary CCPCH Info

-CHOICE TDD option

1.28 Mcps TDD

– Cell parameters ID

Cell parameters ID of Cell 4

– Primary CCPCH TX power

Not present

– Timeslot list

Not present

– Cell for measurement

Not present

– Inter-frequency measurement quantity

– CHOICE reporting criteria

Inter-frequency reporting criteria

– Filter Coefficient

0

– Measurement quantity for frequency quality estimate

P-CCPCH RSCP

– Inter-frequency reporting quantity

– UTRAN carrier RSSI

FALSE

– Frequency quality estimate

FALSE

– Non frequency related quantities

– SFN-SFN observed time difference reporting indicator

No report

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CHOICE mode

TDD

– Timeslot ISCP reporting indicator

FALSE

– Proposed TGSN reporting indicator

FALSE

– Primary CCPCH RSCP reporting indicator

FALSE

– Pathloss reporting indicator

FALSE

– Measurement validity

CELL_DCH state

– CHOICE report criteria

Inter-frequency measurement reporting criteria

– Parameters required for each events

– Inter-frequency event identity

2A

– Threshold used frequency

Not present

– W used frequency

0

– Hysteresis

29 (14.5 dB)

– Time to trigger

5000 mSec

– Reporting cell status

Not present

– Parameters required for each non-used frequency

– Threshold non-used frequency

-72 dBm

– W non-used frequency

0

Measurement reporting mode

– Measurement reporting transfer mode

Acknowledged mode RLC

– Periodic reporting / Event trigger reporting mode

Event trigger

Additional measurement list

– Measurement identity

1

DPCH compressed mode status info

Not present

MEASUREMENT CONTROL (Step 4) (3.84 Mcps TDD)

Information Element

Value/remark

Measurement identity

2

Measurement command

Setup

– CHOICE measurement type

Inter-frequency measurement

– Inter-frequency measurement objects list

– Inter-frequency cell removal

Not present

– New inter-frequency cells

– Inter-frequency cell id

Id of Cell 4

– Frequency Info

Frequency of Cell 4

– Cell info

– Cell individual offset

Not present

– Reference time difference to cell

Not present

– Read SFN Indicator

FALSE

– CHOICE mode

TDD

– Primary CCPCH Info

– CHOICE mode

TDD

– CHOICE TDD option

3.84 Mcps TDD

– CHOICE SyncCase

SyncCase 1

– Timeslot

4

– Cell parameters ID

Cell parameters ID of Cell 4

– SCTD indicator

FALSE

– Primary CCPCH TX power

Not present

– Timeslot list

Not present

– Cell for measurement

Not present

– Inter-frequency measurement quantity

– CHOICE reporting criteria

Inter-frequency reporting criteria

– Filter Coefficient

0

– CHOICE mode

TDD

– Measurement quantity for frequency quality estimate

P-CCPCH RSCP

– Inter-frequency reporting quantity

– UTRAN carrier RSSI

FALSE

– Frequency quality estimate

FALSE

– Non frequency related quantities

– SFN-SFN observed time difference reporting indicator

No report

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CHOICE mode

TDD

– Timeslot ISCP reporting indicator

FALSE

– Proposed TGSN reporting indicator

FALSE

– Primary CCPCH RSCP reporting indicator

FALSE

– Pathloss reporting indicator

FALSE

– Measurement validity

CELL_DCH state

– CHOICE report criteria

Inter-frequency measurement reporting criteria

– Parameters required for each events

– Inter-frequency event identity

2A

– Threshold used frequency

Not present

– W used frequency

0

– Hysteresis

29 (14.5 dB)

– Time to trigger

5000 mSec

– Reporting cell status

Not present

– Parameters required for each non-used frequency

– Threshold non-used frequency

-72 dBm

– W non-used frequency

0

Measurement reporting mode

– Measurement reporting transfer mode

Acknowledged mode RLC

– Periodic reporting / Event trigger reporting mode

Event trigger

Additional measurement list

– Measurement identity

1

DPCH compressed mode status info

Not present

MEASUREMENT CONTROL (Step 4) (7.68 Mcps TDD)

Information Element

Value/remark

Measurement identity

2

Measurement command

Setup

– CHOICE measurement type

Inter-frequency measurement

– Inter-frequency measurement objects list

– Inter-frequency cell removal

Not present

– New inter-frequency cells

– Inter-frequency cell id

Id of Cell 4

– Frequency Info

Frequency of Cell 4

– Cell info

– Cell individual offset

Not present

– Reference time difference to cell

Not present

– Read SFN Indicator

FALSE

– CHOICE mode

TDD

– Primary CCPCH Info

– CHOICE mode

TDD

– CHOICE TDD option

7.68 Mcps TDD

– CHOICE SyncCase

SyncCase 1

– Timeslot

4

– Cell parameters ID

Cell parameters ID of Cell 4

– SCTD indicator

FALSE

– Primary CCPCH TX power

Not present

– Timeslot list

Not present

– Cell for measurement

Not present

– Inter-frequency measurement quantity

– CHOICE reporting criteria

Inter-frequency reporting criteria

– Filter Coefficient

0

– CHOICE mode

TDD

– Measurement quantity for frequency quality estimate

P-CCPCH RSCP

– Inter-frequency reporting quantity

– UTRAN carrier RSSI

FALSE

– Frequency quality estimate

FALSE

– Non frequency related quantities

– SFN-SFN observed time difference reporting indicator

No report

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CHOICE mode

TDD

– Timeslot ISCP reporting indicator

FALSE

– Proposed TGSN reporting indicator

FALSE

– Primary CCPCH RSCP reporting indicator

FALSE

– Pathloss reporting indicator

FALSE

– Measurement validity

CELL_DCH state

– CHOICE report criteria

Inter-frequency measurement reporting criteria

– Parameters required for each events

– Inter-frequency event identity

2A

– Threshold used frequency

Not present

– W used frequency

0

– Hysteresis

29 (14.5 dB)

– Time to trigger

5000 mSec

– Reporting cell status

Not present

– Parameters required for each non-used frequency

– Threshold non-used frequency

-72 dBm

– W non-used frequency

0

Measurement reporting mode

– Measurement reporting transfer mode

Acknowledged mode RLC

– Periodic reporting / Event trigger reporting mode

Event trigger

Additional measurement list

– Measurement identity

1

DPCH compressed mode status info

Not present

MEASUREMENT CONTROL (Step 8)

Information Element

Value/remark

Measurement identity

2

Measurement command

Modify

– CHOICE measurement type

Inter-frequency measurement

– Inter-frequency cell info list

– Inter-frequency cell removal

Not present

– New inter-frequency info list

Not present

– Cell for measurement

Not present

– Inter-frequency measurement quantity

Not present

– Inter-frequency reporting quantity

Not present

– Measurement validity

Not present

– UE autonomous update mode

Not present

– CHOICE report criteria

Inter-frequency measurement reporting criteria

– Parameters required for each events

– Inter-frequency event identity

2A

– Threshold used frequency

Not present

– W used frequency

0

– Hysteresis

2 (1 dB)

– Time to trigger

5000 mSec

– Reporting cell status

Not present

– Parameters required for each non-used frequency

– Threshold non-used frequency

-72 dBm

– W non-used frequency

0

Measurement reporting mode

Not present

Additional measurement list

Not present

DPCH compressed mode status info

Not present

MEASUREMENT REPORT (Step 13) (FDD)

Information Element

Value/remark

Measurement identity

Check to see if set to 2

Measured results

Check to see if it is absent

Measured results on RACH

Check to see if it is absent

Additional measured results

– Measured results

UE internal measured results

– UE transmitted power

Check to see if it is present

– UE RX TX report entry list

Check to see if it is absent

Event results

Inter-frequency measurement event results,

– Inter-frequency event identity

2A

– Cell measurement event results

– Frequency info

– UARFCN uplink

The presence of this IE is not checked

– UARFCN downlink

Check that the value of this IE is set to UARFCN for the downlink corresponding to f4

– Primary CPICH info

– Primary scrambling code

Primary scrambling code of Cell 4

MEASUREMENT REPORT (Step 13) (1.28 Mcps TDD)

Information Element

Value/remark

Measurement identity

Check to see if set to 2

Measured results

Check to see if it is absent

Measured results on RACH

Check to see if it is absent

Additional measured results

– Measured results

UE internal measured results

– UE transmitted power

Check to see if it is present

– TADV

Check to see if it is absent

Event results

Check to see if set to “Inter-frequency measurement event results”

– Inter-frequency event identity

Check to see if set to “2A”

– Inter-frequency Cells

– Frequency info

Check to see if set to Frequency of Cell 4

– Non frequency related measurement event results

– CHOICE mode

Check to see if set to “TDD”

– Primary CCPCH info

– Cell parameters ID

Check to see if set to Cell parameter ID of Cell 4

MEASUREMENT REPORT (Step 13) (3.84 Mcps TDD)

Information Element

Value/remark

Measurement identity

Check to see if set to 2

Measured results

Check to see if it is absent

Measured results on RACH

Check to see if it is absent

Additional measured results

– Measured results

UE internal measured results

CHOICE mode

Check to see if set to “TDD”

– UE transmitted power

Check to see if it is present

CHOICE TDD option

Check to see if set to “3.84 Mcps TDD”

– Applied TA

Check to see if it is absent

Event results

Check to see if set to “Inter-frequency measurement event results”

– Inter-frequency event identity

Check to see if set to “2A”

– Inter-frequency Cells

– Frequency info

Check to see if set to Frequency of Cell 4

– Non frequency related measurement event results

CHOICE mode

Check to see if set to “TDD”

– Primary CCPCH info

CHOICE mode

Check to see if set to “TDD”

CHOICE TDD option

Check to see if set to “3.48 Mcps TDD”

CHOISE SyncCase

Check to see if set to “Sync Case 1”

– Timeslot

Check to see if set to “4”

– Cell parameters ID

Check to see if set to Cell parameter ID of Cell 4

– SCTD indicator

Check to see if set to “FALSE”

MEASUREMENT REPORT (Step 13) (7.68 Mcps TDD)

Information Element

Value/remark

Measurement identity

Check to see if set to 2

Measured results

Check to see if it is absent

Measured results on RACH

Check to see if it is absent

Additional measured results

– Measured results

UE internal measured results

CHOICE mode

Check to see if set to “TDD”

– UE transmitted power

Check to see if it is present

CHOICE TDD option

Check to see if set to “7.68 Mcps TDD”

– Applied TA

Check to see if it is absent

Event results

Check to see if set to “Inter-frequency measurement event results”

– Inter-frequency event identity

Check to see if set to “2A”

– Inter-frequency Cells

– Frequency info

Check to see if set to Frequency of Cell 4

– Non frequency related measurement event results

CHOICE mode

Check to see if set to “TDD”

– Primary CCPCH info

CHOICE mode

Check to see if set to “TDD”

CHOICE TDD option

Check to see if set to “7.68 Mcps TDD”

CHOISE SyncCase

Check to see if set to “Sync Case 1”

– Timeslot

Check to see if set to “4”

– Cell parameters ID

Check to see if set to Cell parameter ID of Cell 4

– SCTD indicator

Check to see if set to “FALSE”

8.4.1.24.5 Test Requirement

1.A In step 13 the UE shall send MEASUREMENT REPORT message indicating event 2A. IE ‘ Inter-frequency Cells ‘ in MEASUREMENT REPORT message shall contain frequency information and primary scrambling code (for FDD) or Cell parameters ID (forTDD) of Cell 4.

1.B In step 6, the UE shall not send MEASUREMENT REPORT message.

1.C In step 11, the UE shall not send MEASUREMENT REPORT message.

8.4.1.24a Measurement Control and Report: Inter-band measurement for event 2A

8.4.1.24a.1 Definition

This test case is identical to test case 8.4.1.24 except that the cells belong to different frequency bands.

8.4.1.24a.2 Conformance requirement

Same conformance requirement as in clause 8.4.1.24.2.

8.4.1.24a.3 Test Purpose

Same test purpose as in clause 8.4.1.24.3 except that the cells belong to different frequency bands.

8.4.1.24a.4 Method of test

Initial Condition

Same initial conditions as in clause 8.4.1.24.4 except that cell1 and cell4 use URAFCNs selected from different frequency band.

Related ICS/IXIT statements

– Compressed mode required yes/no

– UE supports multiple bands simultaneously yes/no

Test Procedure

Same test procedure as in clause 8.4.1.24.4.

Note: If the UE supports more than 2 frequency bands, the test may be executed for various band combinations.

Expected Sequence

Same expected sequence as in clause 8.4.1.24.4.

Specific Message Content

Same specific message content as in clause 8.4.1.24.4.

8.4.1.24a.5 Test Requirement

Same test requirement as in clause 8.4.1.24.5.

8.4.1.25 Measurement Control and Report: Inter-frequency measurement for events 2B and 2E

8.4.1.25.1 Definition

8.4.1.25.2 Conformance requirement

When event 2b is configured in the UE within a measurement, the UE shall:

1> if equations 1 and 2 below have been fulfilled for a time period indicated by "Time to Trigger" from the same instant, respectively for one or several non-used frequencies included for that event and for the used frequency:

2> if any of those non-used frequency is not stored in the variable TRIGGERED_2B_EVENT:

3> store the non-used frequencies that triggered the event and that were not previously stored in the variable TRIGGERED_2B_EVENT into that variable;

3> send a measurement report with IEs set as below:

4> set in "inter-frequency measurement event results":

5> "inter-frequency event identity" to "2b"; and

5> for each non-used frequency that triggered the event, beginning with the best frequency:

6> "Frequency info" to that non-used frequency; and

6> "Non frequency related measurement event results" to the "Primary CPICH info" of the best primary CPICH for FDD cells or "Primary CCPCH info" to the "Cell parameters ID" of the best primary CCPCH for TDD cells on that non-used frequency, not taking into account the cell individual offset;

4> set the IE "measured results" and the IE "additional measured results" according to TS 25.331 subclause 8.4.2, not taking into account the cell individual offset;

1> if equation 3 below is fulfilled for a non-used frequency stored in the variable TRIGGERED_2B_EVENT:

2> remove that non-used frequency from the variable TRIGGERED_2B_EVENT.

1> if equation 4 below is fulfilled for the used frequency:

2> clear the variable TRIGGERED_2B_EVENT.

Triggering conditions:

Equation 1:

The variables in the formula are defined as follows:

QNon used is the quality estimate of a non-used frequency that becomes better than an absolute threshold.

TNon used 2b is the absolute threshold that applies for this non-used frequency in that measurement.

H2b is the hysteresis parameter for the event 2b.

Equation 2:

The variables in the formula are defined as follows:

QUsed is the quality estimate of the used frequency.

TUsed 2b is the absolute threshold that applies for the used frequency in that measurement.

H2b is the hysteresis parameter for the event 2b.

Leaving triggered state condition:

Equation 3:

The variables in the formula are defined as follows:

QNon used is the quality estimate of a non-used frequency that is stored in the variable TRIGGERED_2B_EVENT.

TNon used 2b is the absolute threshold that applies for this non-used frequency in that measurement.

H2b is the hysteresis parameter for the event 2b.

Equation 4:

The variables in the formula are defined as follows:

QUsed is the quality estimate of the used frequency.

TUsed 2b is the absolute threshold that applies for the used frequency in that measurement.

H2b is the hysteresis parameter for the event 2b.

When event 2e is configured in the UE within a measurement, the UE shall:

1> if equation 1 below has been fulfilled for one or several non-used frequencies included for that event during the time "Time to trigger":

2> if any of those non-used frequencies is not stored in the variable TRIGGERED_2E_EVENT:

3> store the non-used frequencies that triggered the event and that were not previously stored in the variable TRIGGERED_2E_EVENT into that variable;

3> send a measurement report with IEs set as below:

4> set in "inter-frequency measurement event results":

5> "inter-frequency event identity" to "2e"; and

5> for each non-used frequency that triggered the event, beginning with the best frequency:

6> "Frequency info" to that non-used frequency; and

6> "Non frequency related measurement event results" to the "Primary CPICH info" of the best primary CPICH for FDD cells or "Primary CCPCH info" to the "Cell parameters ID" of the best primary CCPCH for TDD cells on that non-used frequency, not taking into account the cell individual offset;

4> set the IE "measured results" and the IE "additional measured results" according to TS 25.331 subclause 8.4.2, not taking into account the cell individual offset;

1> if equation 2 below is fulfilled for a non-used frequency stored in the variable TRIGGERED_2E_EVENT:

2> remove that non-used frequency from the variable TRIGGERED_2E_EVENT.

Triggering condition:

Equation 1:

The variables in the formula are defined as follows:

QNon used is the quality estimate of a non-used frequency that becomes worse than an absolute threshold.

TNon used 2e is the absolute threshold that applies for that non-used frequency for that event.

H2e is the hysteresis parameter for the event 2e.

Leaving triggered state condition:

Equation 2:

The variables in the formula are defined as follows:

QNon used is the quality estimate of a non-used frequency stored in the variable TRIGGERED_2E_EVENT.

TNon used 2e is the absolute threshold that applies for that non-used frequency for that event.

H2e is the hysteresis parameter for the event 2e.

Reference

3GPP TS 25.331 clause 14.2.1.2, 14.2.1.5.

8.4.1.25.3 Test Purpose

1. To confirm that the UE sends MEASUREMENT REPORT message when event 2E is configured and the estimated quality of a non-used frequency is below the value of the IE "Threshold non-used frequency". This MEASUREMENT REPORT message shall contain at least the best primary CPICH info (for FDD) or primary CCPCH info (for TDD) on the non-used frequency that triggered the event.

2. To confirm that the UE sends MEASUREMENT REPORT message when event 2B is configured and estimated quality of the currently used frequency is below the value of the IE "Threshold used frequency" and the estimated quality of a non-used frequency is above the value of the IE "Threshold non-used frequency". This MEASUREMENT REPORT message shall contain at least the best primary CPICH info (for FDD) or primary CCPCH info (for TDD)on the non-used frequency that triggered the event.

8.4.1.25.4 Method of test

Initial Condition

System Simulator: 2 cells – The initial configurations of the 2 cells in the SS shall follow the values indicated in the column marked "T0" in table 8.4.1.25-1. The table is found in "Test Procedure" clause.

UE: CS-DCCH+DTCH_DCH (State 6-9) or PS-DCCH+DTCH_DCH (State 6-10) in cell 1 as specified in clause 7.4 of TS 34.108, depending on the CN domain supported by the UE.

Related ICS/IXIT statements

– Compressed mode required yes/no

Test Procedure

Table 8.4.1.25-1 illustrates the downlink power to be applied for the 2 cells at various time instants of the test execution. Column marked "T0" denotes the initial conditions, while columns marked "T1" and "T2" are to be applied subsequently. The exact instants on which these values shall be applied are described in the text in this clause.

Table 8.4.1.25-1

Parameter

Unit

Cell 1

Cell 4

T0

T1

T2

T0

T1

T2

UTRA RF Channel Number

Mid Range Test Frequency

High Range Test Frequency

CPICH Ec (FDD)

dBm/3.84 MHz

-55

-55

-85

-85

-55

-55

P-CCPCH RSCP(TDD)

dBm

-60

-60

-80

-80

-60

-60

P-CCPCH TS (3.84 Mcps TDD) and 7.68 Mcps TDD

TS 0

TS 4

The UE is initially in CELL_DCH state of cell 1. SS commands the UE to perform Inter-frequency measurements and report event 2B and event 2E by sending MEASUREMENT CONTROL message. Note that the Filter Coefficient IE has a value of 4 so Layer 3 Filtering applies in this case.

If UE requires compressed mode, SS performs PHYSICAL CHANNEL RECONFIGURATION procedure to activate compressed mode (for FDD only).

Since quality estimate of non-used frequency is below threshold, the UE sends MEASUREMENT REPORT message indicating event 2E.

SS then configures itself according to the values in columns "T1" shown above. Now quality estimate of used and non-used frequency is above threshold and hence neither event 2B nor event 2E will be triggered. SS then configures itself according to the values in columns "T2" shown above. Quality estimate for used frequency is now below threshold, while that of non-used frequency is above threshold, the UE sends MEASUREMENT REPORT message to report event 2B.

SS calls for generic procedure C.3 to check that UE is in CELL_DCH state.

Expected Sequence

Step

Direction

Message

Comment

UE

SS

1

MEASUREMENT CONTROL

SS commands the UE to perform Inter-frequency measurements and to report event 2B and 2E.

If Compressed Mode not required (refer ICS/IXIT) go to step 4

2

PHYSICAL CHANNEL RECONFIGURATION

SS instructs UE to begin compressed mode operation.

(for FDD only)

3

PHYSICAL CHANNEL RECONFIGURATION COMPLETE

(for FDD only)

4

MEASUREMENT REPORT

The UE shall report event 2E. Time duration between activation of compressed mode and reception of this message should be at least 5 seconds.

Layer 3 Filtering causes an additional delay.

5

SS re-adjusts the downlink transmission power settings according to columns "T1" in table 8.4.1.25-1.

6

Check for 10 seconds the UE shall not send measurement report message.

7

SS re-adjusts the downlink transmission power settings according to columns "T2" in table 8.4.1.25-1.

8

MEASUREMENT REPORT

The UE shall report event 2B. Time duration between changing power levels according to columns "T2" and reception of this message should be at least 5 seconds. Layer 3 Filtering causes an additional delay. For Cell 1 the CPICH Ec value of -80 dBm(for FDD)or the P-CCPCH RSCP value of -75 dBm (for TDD) would have to be reported at least three times from the Physical Layer to cause the Cell 1 frequency threshold to be reached. Depending on tolerance values this number will be greater (CPICH Ec (for FDD) or P-CCPCH RSCP(for TDD) is +/- 3 dBm, SS set Hysteresis value is +/- 2dB)

9



CALL C.3

If the test result of C.3 indicates that UE is in CELL_DCH state, the test passes, otherwise it fails.

Specific Message Contents

All messages indicated below shall use the same content as described in default message content, with the following exceptions:

MEASUREMENT CONTROL (Step 1)(FDD)

Information Element

Value/remark

Measurement identity

4

Measurement command

Setup

– CHOICE measurement type

Inter-frequency measurement

– Inter-frequency cell info list

– Inter-frequency cell removal

Not present

– New inter-frequency info list

– Inter-frequency cell id

Id of Cell 4

– Frequency Information

Frequency of Cell 4

– Cell info

– Cell individual offset

Not present

– Reference time difference to cell

Not present

– CHOICE mode

FDD

– Read SFN Indicator

FALSE

– Primary CPICH Info

– Primary scrambling code

Primary scrambling code of Cell 4

– Primary CPICH TX power

Not present

– TX Diversity Indicator

FALSE

– Cell for measurement

Not present

– Inter-frequency measurement quantity

– Filter Coefficient

4

– Frequency quality estimate quantity

CPICH RSCP

– Inter-frequency reporting quantity

– UTRAN Carrier RSSI

FALSE

– Frequency quality estimate

FALSE

– Non frequency related quantities

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CPICH Ec/No reporting indicator

FALSE

– CPICH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Measurement validity

Not present

– Inter-frequency SET UPDATE

– UE autonomous update mode

On with no reporting

– CHOICE report criteria

Inter-frequency measurement reporting criteria

– Parameters required for each events

– Inter-frequency event identity

2E

– Hysteresis

2 (1 dB)

– Time to trigger

5000 mSec

– Reporting cell status

Not present

– Non used frequency parameter list

– Non used frequency threshold

-70 dBm

– Non used frequency W

0

– Inter-frequency event identity

2B

– Used frequency threshold

-70 dBm

– Used frequency W

0.4

– Hysteresis

2 (1 dB)

– Time to trigger

5000 mSec

– Reporting cell status

Within active set or within virtual active set or of the other RAT

– Maximum number of reporting cells

1

– Non used frequency parameter list

– Non used frequency threshold

-70 dBm

– Non used frequency W

0

Measurement reporting mode

– Measurement reporting transfer mode

Unacknowledged Mode RLC

– Periodic reporting / Event trigger reporting mode

Event trigger

Additional measurement list

Not present

DPCH compressed mode status info

Not present

MEASUREMENT CONTROL (Step 1)( 1.28 Mcps TDD)

Information Element

Value/remark

Measurement identity

4

Measurement command

Setup

– CHOICE measurement type

Inter-frequency measurement

– Inter-frequency measurement objects list

– Inter-frequency cell removal

Not present

– New inter-frequency cells

– Inter-frequency cell id

Id of Cell 4

– Frequency Information

Frequency of Cell 4

– Cell info

– Cell individual offset

Not present

– Reference time difference to cell

Not present

– Read SFN Indicator

FALSE

– CHOICE mode

TDD

– Primary CCPCH Info

– CHOICE mode

TDD

– CHOICE TDD option

1.28 Mcps TDD

– TSTD Indicator

FALSE

– Cell parameters ID

Cell parameters ID of Cell 4

– Primary CCPCH TX power

Not present

– Timeslot list

Not present

– Cell for measurement

Not present

– Inter-frequency measurement quantity

– CHOICE reporting criteria

Inter-frequency reporting criteria

– Filter Coefficient

4

– CHOICE mode

TDD

– Measurement quantity for frequency quality estimate

P-CCPCH RSCP

– Inter-frequency reporting quantity

– UTRAN Carrier RSSI

FALSE

– Frequency quality estimate

FALSE

– Non frequency related quantities

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CHOICE mode

TDD

– Timeslot ISCP reporting indicator

FALSE

– Proposed TGSN reporting indicator

FALSE

– Primary CCPCH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Measurement validity

Not present

– CHOICE report criteria

Inter-frequency measurement reporting criteria

– Parameters required for each events

– Inter-frequency event identity

2E

– Hysteresis

2 (1 dB)

– Time to trigger

5000 mSec

– Reporting cell status

Not present

– Parameters required for each non-used frequency

– Threshold non used frequency

-70dBm

– W non-used frequency

0

– Inter-frequency event identity

2B

– Threshold used frequency

-70 dBm

– W used frequency

0.4

– Hysteresis

2 (1 dB)

– Time to trigger

5000 mSec

– Reporting cell status

Within active set or within virtual active set or of the other RAT

– Maximum number of reporting cells

1

– Parameters required for each non-used frequency

– Threshold non used frequency

-70 dBm

– W non-used frequency

0

Measurement reporting mode

– Measurement reporting transfer mode

Unacknowledged Mode RLC

– Periodic reporting / Event trigger reporting mode

Event trigger

Additional measurement list

Not present

DPCH compressed mode status info

Not present

MEASUREMENT CONTROL (Step 1)( 3.84 Mcps TDD)

Information Element

Value/remark

Measurement identity

4

Measurement command

Setup

– CHOICE measurement type

Inter-frequency measurement

– Inter-frequency measurement objects list

– Inter-frequency cell removal

Not present

– New inter-frequency cells

– Inter-frequency cell id

Id of Cell 4

– Frequency Information

Frequency of Cell 4

– Cell info

– Cell individual offset

Not present

– Reference time difference to cell

Not present

– Read SFN Indicator

FALSE

– CHOICE mode

TDD

– Primary CCPCH Info

– CHOICE mode

TDD

– CHOICE TDD option

3.84 Mcps TDD

– CHOICE SyncCase

SyncCase 1

– Timeslot

4

– Cell parameters ID

Cell parameters ID of Cell 4

– SCTD indicator

FALSE

– Primary CCPCH TX power

Not present

– Timeslot list

Not present

– Cell for measurement

Not present

– Inter-frequency measurement quantity

– CHOICE reporting criteria

Inter-frequency reporting criteria

– Filter Coefficient

4

– CHOICE mode

TDD

– Measurement quantity for frequency quality estimate

P-CCPCH RSCP

– Inter-frequency reporting quantity

– UTRAN Carrier RSSI

FALSE

– Frequency quality estimate

FALSE

– Non frequency related quantities

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CHOICE mode

TDD

– Timeslot ISCP reporting indicator

FALSE

– Proposed TGSN reporting indicator

FALSE

– Primary CCPCH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Measurement validity

Not present

– CHOICE report criteria

Inter-frequency measurement reporting criteria

– Parameters required for each events

– Inter-frequency event identity

2E

– Hysteresis

2 (1 dB)

– Time to trigger

5000 mSec

– Reporting cell status

Within active set or within virtual active set or of the other RAT

– Parameters required for each non-used frequency

– Threshold non used frequency

-70dBm

– W non-used frequency

0

– Inter-frequency event identity

2B

– Threshold used frequency

-70 dBm

– W used frequency

0.4

– Hysteresis

2 (1 dB)

– Time to trigger

5000 mSec

– Reporting cell status

Not present

– Maximum number of reporting cells

1

– Parameters required for each non-used frequency

– Threshold non used frequency

-70 dBm

– W non-used frequency

0

Measurement reporting mode

– Measurement reporting transfer mode

Unacknowledged Mode RLC

– Periodic reporting / Event trigger reporting mode

Event trigger

Additional measurement list

Not present

DPCH compressed mode status info

Not present

MEASUREMENT CONTROL (Step 1)( 3.84 Mcps TDD)

Information Element

Value/remark

Measurement identity

4

Measurement command

Setup

– CHOICE measurement type

Inter-frequency measurement

– Inter-frequency measurement objects list

– Inter-frequency cell removal

Not present

– New inter-frequency cells

– Inter-frequency cell id

Id of Cell 4

– Frequency Information

Frequency of Cell 4

– Cell info

– Cell individual offset

Not present

– Reference time difference to cell

Not present

– Read SFN Indicator

FALSE

– CHOICE mode

TDD

– Primary CCPCH Info

– CHOICE mode

TDD

– CHOICE TDD option

7.68 Mcps TDD

– CHOICE SyncCase

SyncCase 1

– Timeslot

4

– Cell parameters ID

Cell parameters ID of Cell 4

– SCTD indicator

FALSE

– Primary CCPCH TX power

Not present

– Timeslot list

Not present

– Cell for measurement

Not present

– Inter-frequency measurement quantity

– CHOICE reporting criteria

Inter-frequency reporting criteria

– Filter Coefficient

4

– CHOICE mode

TDD

– Measurement quantity for frequency quality estimate

P-CCPCH RSCP

– Inter-frequency reporting quantity

– UTRAN Carrier RSSI

FALSE

– Frequency quality estimate

FALSE

– Non frequency related quantities

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CHOICE mode

TDD

– Timeslot ISCP reporting indicator

FALSE

– Proposed TGSN reporting indicator

FALSE

– Primary CCPCH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Measurement validity

Not present

– CHOICE report criteria

Inter-frequency measurement reporting criteria

– Parameters required for each events

– Inter-frequency event identity

2E

– Hysteresis

2 (1 dB)

– Time to trigger

5000 mSec

– Reporting cell status

Within active set or within virtual active set or of the other RAT

– Parameters required for each non-used frequency

– Threshold non used frequency

-70dBm

– W non-used frequency

0

– Inter-frequency event identity

2B

– Threshold used frequency

-70 dBm

– W used frequency

0.4

– Hysteresis

2 (1 dB)

– Time to trigger

5000 mSec

– Reporting cell status

Not present

– Maximum number of reporting cells

1

– Parameters required for each non-used frequency

– Threshold non used frequency

-70 dBm

– W non-used frequency

0

Measurement reporting mode

– Measurement reporting transfer mode

Unacknowledged Mode RLC

– Periodic reporting / Event trigger reporting mode

Event trigger

Additional measurement list

Not present

DPCH compressed mode status info

Not present

PHYSICAL CHANNEL RECONFIGURATION (Step 2)

Use the same message sub-type found in Annex A, which is entitled "(Packet to CELL_DCH from CELL_DCH in PS)", with the following exceptions in the IE(s) concerned:

Information Element

Value/remark

Version

Downlink information common for all radio links

– Downlink DPCH info common for all RL

– Timing Indication

Maintain

– Downlink DPCH power control information

– DPC mode

0 (Single)

– CHOICE Mode

FDD

– Power offset PPilot-DPDCH

0

– DL rate matching restriction information

Not present

– Spreading factor

Refer to the parameter set in TS 34.108

– Fixed or flexible position

Flexible

– TFCI existence

TRUE

– Number of bits for Pilot bits (SF=128, 256)

Not present

– DPCH compressed mode info

– TGPSI

1

– TGPS status flag

Activate

– TGCFN

(Current CFN+(256 – TTI/10msec)) mod 256

– Transmission gap pattern sequence configuration parameters

– TGMP

FDD Measurement

– TGPRC

Infinity

– TGSN

4

– TGL1

7

– TGL2

Not Present

– TGD

Undefined

– TGPL1

3

– TGPL2

Not Present

R99 and REL-4 only

– RPP

Mode 0

– ITP

Mode 0

– CHOICE UL/DL mode

UL and DL or DL only or UL only depending on UE capability

– Downlink compressed mode method

SF/2

– Uplink compressed mode method

SF/2 or Not present depending on UE capability

– Downlink frame type

A

– DeltaSIR1

20 (2.0)

– DeltaSIRAfter1

10 (1.0)

– DeltaSIR2

Not present

– DeltaSIRAfter2

Not present

– N identify abort

Not present

– T Reconfirm abort

Not present

– TX diversity mode

None

– SSDT information

Not present

R99 and Rel-4 only

– Default DPCH offset value

Not present

MEASUREMENT REPORT (Step 4) (FDD)

Information Element

Value/remark

Measurement identity

Check to see if set to 4

Measured results

Check to see if it is absent

Measured results on RACH

Check to see if it is absent

Additional measured results

Check to see if it is absent

Event results

Inter-frequency measurement event results,

– Inter-frequency event identity

2E

– Cell measurement event results

– Frequency info

– UARFCN uplink (Nu)

The presence of this IE is not checked

– UARFCN downlink (Nd)

Check that the value of this IE is set to UARFCN for the downlink corresponding to f4

– Primary CPICH info

– Primary scrambling code

Primary scrambling code of Cell 4

MEASUREMENT REPORT (Step 4) (1.28 Mcps TDD)

Information Element

Value/remark

Measurement identity

Check to see if set to 4

Measured results

Check to see if it is absent

Measured results on RACH

Check to see if it is absent

Additional measured results

Check to see if it is absent

Event results

– CHOICE event results

Check to see if set to “Inter-frequency measurement event results”

– Inter-frequency event identity

Check to see if set to “2E”

– Inter-frequency cells

– Frequency info

Check to see if set to Frequency of Cell 4

– Non-frequency related measurement event results

– CHOICE mode

Check to see if set to “TDD”

– Primary CCPCH info

– CHOICE mode

Check to see if set to “TDD”

– CHOICE mode option

Check to see if set to “1.28 Mcps TDD”

– TSTD Indicator

Check to see if set to “FALSE”

– Cell parameters ID

Check to see if set to Cell parameters ID of Cell 4

– SCTD Indicator

Check to see if set to “FALSE”

MEASUREMENT REPORT (Step 4) (3.84 Mcps TDD)

Information Element

Value/remark

Measurement identity

Check to see if set to 4

Measured results

Check to see if it is absent

Measured results on RACH

Check to see if it is absent

Additional measured results

Check to see if it is absent

Event results

– CHOICE event results

Check to see if set to “Inter-frequency measurement event results”

– Inter-frequency event identity

Check to see if set to “2E”

– Inter-frequency cells

– Frequency info

Check to see if set to Frequency of Cell 4

– Non-frequency related measurement event results

– CHOICE mode

Check to see if set to “TDD”

– Primary CCPCH info

CHOICE mode

Check to see if set to “TDD”

– CHOICE mode option

Check to see if set to “3.48 Mcps TDD”

CHOISE SyncCase

Check to see if set to “Sync Case 1”

– Timeslot

Check to see if set to “4”

– Cell parameters ID

Check to see if set to Cell parameters ID of Cell 4

– SCTD indicator

Check to see if set to “FALSE”

MEASUREMENT REPORT (Step 4) (7.68 Mcps TDD)

Information Element

Value/remark

Measurement identity

Check to see if set to 4

Measured results

Check to see if it is absent

Measured results on RACH

Check to see if it is absent

Additional measured results

Check to see if it is absent

Event results

– CHOICE event results

Check to see if set to “Inter-frequency measurement event results”

– Inter-frequency event identity

Check to see if set to “2E”

– Inter-frequency cells

– Frequency info

Check to see if set to Frequency of Cell 4

– Non-frequency related measurement event results

– CHOICE mode

Check to see if set to “TDD”

– Primary CCPCH info

CHOICE mode

Check to see if set to “TDD”

– CHOICE mode option

Check to see if set to “7.68 Mcps TDD”

CHOISE SyncCase

Check to see if set to “Sync Case 1”

– Timeslot

Check to see if set to “4”

– Cell parameters ID

Check to see if set to Cell parameters ID of Cell 4

– SCTD indicator

Check to see if set to “FALSE”

MEASUREMENT REPORT (Step 8) (FDD)

Information Element

Value/remark

Measurement identity

4

Measured results

Inter-frequency measured results

– Frequency info

– UARFCN uplink

The presence of this IE is not checked

– UARFCN downlink

Check that the value of this IE is set to UARFCN for the downlink corresponding to f4

– UTRA carrier RSSI

Check to see if it is absent

– Inter-frequency cell measured results

– Cell Identity

Check to see if it is absent

– Cell synchronisation information

Check to see if this IE is absent

– Mode Specific Info

FDD

– Primary CPICH Info

– Primary scrambling code

Primary scrambling code for cell 4

– CPICH Ec/No

Check to see if it is absent

– CPICH RSCP

Check to see if it is present

– Pathloss

Check to see if it is absent

Measured results on RACH

Check to see if it is absent

Additional measured results

Check to see if it is absent

Event results

Inter-frequency measurement event results,

– Inter-frequency event identity

2B

– Cell measurement event results

– Frequency info

– UARFCN uplink

The presence of this IE is not checked

– UARFCN downlink

Check that the value of this IE is set to UARFCN for the downlink corresponding to f4

– Primary CPICH info

– Primary scrambling code

Primary scrambling code of Cell 4

MEASUREMENT REPORT (Step 8) (1.28 Mcps TDD)

Information Element

Value/remark

Measurement identity

Check to see if set to 4

Measured results

Check to see if it set to “Inter-frequency measured results list”

– Frequency information

Check to see if set to Frequency of Cell 4

– UTRA carrier RSSI

Check to see if it is absent

– Inter-frequency cell measured results

– Cell measurement results

– Cell Identity

Check to see if it is absent

– Cell synchronisation information

Check to see if this IE is absent

– CHOICE mode

Check to see if set to “TDD”

– Cell parameters ID

Check to see if set to Cell parameters ID for cell 4

– Proposed TGSN

Check to see if it is absent

– Primary CCPCH RSCP

Check to see if it is present

– Pathloss

Check to see if it is absent

– Timeslot List/ISCP

Check to see if it is absent

Measured results on RACH

Check to see if it is absent

Additional measured results

Check to see if it is absent

Event results

– CHOICE event results

Check to see if set to “Inter-frequency measurement event results”

– Inter-frequency event identity

Check to see if set to “2B”

– Inter-frequency cells

– Frequency info

Check to see if set to Frequency of Cell 4

– Non-frequency related measurement event results

– CHOICE mode

Check to see if set to “TDD”

– Primary CCPCH info

– CHOICE mode

Check to see if set to “TDD”

– CHOICE mode option

Check to see if set to “1.28 Mcps TDD”

– TSTD Indicator

Check to see if set to “FALSE”

– Cell parameters ID

Check to see if set to Cell parameters ID of Cell 4

– SCTD Indicator

Check to see if set to “FALSE”

MEASUREMENT REPORT (Step 8) (3.84Mcps TDD)

Information Element

Value/remark

Measurement identity

Check to see if set to 4

Measured results

Check to see if it set to “Inter-frequency measured results list”

– Frequency information

Check to see if set to Frequency of Cell 4

– UTRA carrier RSSI

Check to see if it is absent

– Inter-frequency cell measured results

– Cell measurement results

– Cell Identity

Check to see if it is absent

– Cell synchronisation information

Check to see if this IE is absent

– CHOICE mode

Check to see if set to “TDD”

– Cell parameters ID

Check to see if set to Cell parameters ID for cell 4

– Proposed TGSN

Check to see if it is absent

– Primary CCPCH RSCP

Check to see if it is present

– Pathloss

Check to see if it is absent

– Timeslot list/ISCP

Check to see if it is absent

Measured results on RACH

Check to see if it is absent

Additional measured results

Check to see if it is absent

Event results

– CHOICE event results

Check to see if set to “Inter-frequency measurement event results”

– Inter-frequency event identity

Check to see if set to “2B”

– Inter-frequency cells

– Frequency info

Check to see if set to Frequency of Cell 4

– Non-frequency related measurement event results

– CHOICE mode

Check to see if set to “TDD”

– Primary CCPCH info

CHOICE mode

Check to see if set to “TDD”

– CHOICE mode option

Check to see if set to “3.84 Mcps TDD”

CHOISE SyncCase

Check to see if set to “Sync Case 1”

– Timeslot

Check to see if set to “4”

– Cell parameters ID

Check to see if set to Cell parameters ID of Cell 4

– SCTD indicator

Check to see if set to “FALSE”

MEASUREMENT REPORT (Step 8) (7.68Mcps TDD)

Information Element

Value/remark

Measurement identity

Check to see if set to 4

Measured results

Check to see if it set to “Inter-frequency measured results list”

– Frequency information

Check to see if set to Frequency of Cell 4

– UTRA carrier RSSI

Check to see if it is absent

– Inter-frequency cell measured results

– Cell measurement results

– Cell Identity

Check to see if it is absent

– Cell synchronisation information

Check to see if this IE is absent

– CHOICE mode

Check to see if set to “TDD”

– Cell parameters ID

Check to see if set to Cell parameters ID for cell 4

– Proposed TGSN

Check to see if it is absent

– Primary CCPCH RSCP

Check to see if it is present

– Pathloss

Check to see if it is absent

– Timeslot list/ISCP

Check to see if it is absent

Measured results on RACH

Check to see if it is absent

Additional measured results

Check to see if it is absent

Event results

– CHOICE event results

Check to see if set to “Inter-frequency measurement event results”

– Inter-frequency event identity

Check to see if set to “2B”

– Inter-frequency cells

– Frequency info

Check to see if set to Frequency of Cell 4

– Non-frequency related measurement event results

– CHOICE mode

Check to see if set to “TDD”

– Primary CCPCH info

CHOICE mode

Check to see if set to “TDD”

– CHOICE mode option

Check to see if set to “7.68 Mcps TDD”

CHOISE SyncCase

Check to see if set to “Sync Case 1”

– Timeslot

Check to see if set to “4”

– Cell parameters ID

Check to see if set to Cell parameters ID of Cell 4

– SCTD indicator

Check to see if set to “FALSE”

8.4.1.25.5 Test Requirement

1. In step 4 the UE shall send MEASUREMENT REPORT message indicating event 2E. IE "Cell measurement event results" in this message shall contain frequency information and primary scrambling code(for FDD) or Cell parameters ID (TDD) of Cell 4.

2. In step 8 the UE shall send MEASUREMENT REPORT message indicating event 2B. IE "Cell measurement event results" in this message shall contain frequency information and primary scrambling code (for FDD) or Cell parameters ID (TDD) of Cell 4.

8.4.1.25a Measurement Control and Report: Inter-band measurement for events 2B and 2E

8.4.1.25a.1 Definition

This test case is identical to test case 8.4.1.25 except that the cells belong to different frequency bands.

8.4.1.25a.2 Conformance requirement

Same conformance requirement as in clause 8.4.1.25.2.

8.4.1.25a.3 Test Purpose

Same test purpose as in clause 8.4.1.25.3 except that the cells belong to different frequency bands.

8.4.1.25a.4 Method of test

Initial Condition

Same initial conditions as in clause 8.4.1.25.4 except that cell1 and cell4 use URAFCNs selected from different frequency bands.

Related ICS/IXIT statements

– Compressed mode required yes/no

– UE supports multiple bands simultaneously yes/no

Test Procedure

Same test procedure as in clause 8.4.1.25.4.

Note: If the UE supports more than 2 frequency bands, the test may be executed for various band combinations.

Expected Sequence

Same expected sequence as in clause 8.4.1.25.4.

Specific Message Content

Same specific message content as in clause 8.4.1.25.4.

8.4.1.25a.5 Test Requirement

Same test requirement as in clause 8.4.1.25.5.

8.4.1.26 Measurement Control and Report: Measurement for events 2D and 2F

8.4.1.26.1 Definition

8.4.1.26.2 Conformance requirement

When event 2d is configured in the UE within a measurement, the UE shall:

1> if equation 1 below has been fulfilled for the used frequency during the time "Time to trigger":

2> if the variable TRIGGERED_2D_EVENT is set to FALSE:

3> set the variable TRIGGERED_2D_EVENT to TRUE;

3> send a measurement report with IEs set as below:

4> set in "inter-frequency event results": "inter-frequency event identity" to "2d" and no IE "Inter-frequency cells";

4> set the IE "measured results" and the IE "additional measured results" according to TS 25.331 subclause 8.4.2.

1> if the variable TRIGGERED_2D_EVENT is set to TRUE and if equation 2 is fulfilled for the used frequency:

2> set the variable TRIGGERED_2D_EVENT to FALSE.

Triggering condition:

Equation 1:

The variables in the formula are defined as follows:

QUsed is the quality estimate of the used frequency.

TUsed 2d is the absolute threshold that applies for the used frequency and event 2d.

H2d is the hysteresis parameter for the event 2d.

Leaving triggered state condition:

Equation 2:

The variables in the formula are defined as follows:

QUsed is the quality estimate of the used frequency.

TUsed 2d is the absolute threshold that applies for the used frequency and event 2d.

H2d is the hysteresis parameter for the event 2d.

When event 2f is configured in the UE within a measurement, the UE shall:

1> if equation 1 below has been fulfilled for the used frequency during the time "Time to trigger":

2> if the variable TRIGGERED_2F_EVENT is set to FALSE:

3> set the variable TRIGGERED_2F_EVENT to TRUE;

3> send a measurement report with IEs set as below:

4> set in "inter-frequency event results": "inter-frequency event identity" to "2f", and no IE "Inter-frequency cells";

4> set the IE "measured results" and the IE "additional measured results" according to TS 25.331 subclause 8.4.2.

1> if the variable TRIGGERED_2F_EVENT is set to TRUE and if equation 2 is fulfilled for the used frequency:

2> set the variable TRIGGERED_2F_EVENT to FALSE.

Triggering condition:

Equation 1:

The variables in the formula are defined as follows:

QUsed is the quality estimate of the used frequency.

TUsed 2f is the absolute threshold that applies for the used frequency and event 2f.

H2f is the hysteresis parameter for the event 2f.

Leaving triggered state condition:

Equation 2:

The variables in the formula are defined as follows:

QUsed is the quality estimate of the used frequency.

TUsed 2f is the absolute threshold that applies for the used frequency and event 2f.

H2f is the hysteresis parameter for the event 2f.

Reference

3GPP TS 25.331 clause 14.2.1.4, 14.2.1.6

8.4.1.26.3 Test Purpose

1. To confirm that the UE sends MEASUREMENT REPORT message when event 2F is configured and estimated quality of the currently used frequency is above the value of the IE "Threshold used frequency".

2. To confirm that the UE sends MEASUREMENT REPORT message when event 2D is configured and estimated quality of the currently used frequency is below the value of the IE "Threshold used frequency".

8.4.1.26.4 Method of test

Initial Condition

System Simulator: 1 cells – The initial configurations of the cell in the SS shall follow the values indicated in the column marked "T0" in table 8.4.1.26-1. The table is found in "Test Procedure" clause.

UE: CS-DCCH+DTCH_DCH (State 6-9) or PS-DCCH+DTCH_DCH (State 6-10) in cell 1 as specified in clause 7.4 of TS 34.108, depending on the CN domain supported by the UE.

Test Procedure

Table 8.4.1.26-1 illustrates the downlink power to be applied for the cell at various time instants of the test execution. Column marked "T0" denotes the initial conditions, while columns marked "T1" is to be applied subsequently. The exact instant on which these values shall be applied is described in the text in this clause.

Table 8.4.1.26-1

Parameter

Unit

Cell 1

T0

T1

UTRA RF Channel Number

Mid Range Test Frequency

CPICH Ec (FDD)

dBm/3.84 MHz

-55

-75

P-CCPCH RSCP(TDD)

dBm

-60

-75

The UE is initially in CELL_DCH state of cell 1. SS commands the UE to perform Inter-frequency measurements and report event 2D and/or event 2F by sending MEASUREMENT CONTROL message. Since quality estimate of used frequency is above threshold, the UE sends MEASUREMENT REPORT message indicating event 2F. SS then configures itself according to the values in columns "T1" shown above. Quality estimate for used frequency is now below threshold, the UE sends MEASUREMENT REPORT message to report it. SS calls for generic procedure C.3 to check that UE is in CELL_DCH state.

Expected Sequence

Step

Direction

Message

Comment

UE

SS

1

Void

2

Void

3

Void

4

MEASUREMENT CONTROL

SS commands the UE to perform Inter-frequency measurements and to report event 2D and 2F.

5

MEASUREMENT REPORT

The UE shall report event 2F

6

SS re-adjusts the downlink transmission power settings according to columns "T1" in table 8.4.1.26-1.

7

MEASUREMENT REPORT

The UE shall report event 2D.

8



CALL C.3

If the test result of C.3 indicates that UE is in CELL_DCH state, the test passes, otherwise it fails.

Specific Message Contents

All messages indicated below shall use the same content as described in default message content, with the following exceptions.

MEASUREMENT CONTROL (Step 4) (FDD)

Information Element

Value/remark

Measurement identity

10

Measurement command

Setup

– CHOICE measurement type

Inter-frequency measurement

– Inter-frequency cell info list

– Inter-frequency cell removal

Not present

– New inter-frequency info list

– Inter-frequency cell id

Any valid identity other than that of Cell 1

– Frequency Information

Any valid frequency other than that of Cell 1

– Cell info

– Cell individual offset

Not present

– Reference time difference to cell

Not present

– CHOICE mode

FDD

– Read SFN Indicator

FALSE

– Primary CPICH Info

– Primary scrambling code

Any value of Primary scrambling code

– Primary CPICH TX power

Not present

– TX Diversity Indicator

FALSE

– Cell for measurement

Not present

– Inter-frequency measurement quantity

– Filter Coefficient

4

– Frequency quality estimate quantity

CPICH RSCP

– Inter-frequency reporting quantity

– UTRAN Carrier RSSI

FALSE

– Frequency quality estimate

FALSE

– Non frequency related quantities

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CPICH Ec/No reporting indicator

FALSE

– CPICH RSCP reporting indicator

FALSE

– Pathloss reporting indicator

FALSE

– Measurement validity

CELL_DCH state

– UE autonomous update mode

Not present

– CHOICE report criteria

Inter-frequency measurement reporting criteria

– Parameters required for each events

– Inter-frequency event identity

2D

– Used frequency threshold

-70 dBm

– Used frequency W

0

– Hysteresis

2 (1 dB)

– Time to trigger

5000 mSec

– Reporting cell status

Not present

– Inter-frequency event identity

2F

– Used frequency threshold

-70 dBm

– Used frequency W

0

– Hysteresis

2 (1 dB)

– Time to trigger

5000 mSec

– Reporting cell status

Not present

Measurement reporting mode

– Measurement reporting transfer mode

Unacknowledged Mode RLC

– Periodic reporting / Event trigger reporting mode

Event trigger

Additional measurement list

Not present

DPCH compressed mode status info

Not present

MEASUREMENT CONTROL (Step 4) (1.28 Mcps TDD)

Information Element

Value/remark

Measurement identity

10

Measurement command

Setup

Measurement reporting mode

– Measurement reporting transfer mode

Unacknowledged Mode RLC

– Periodic reporting / Event trigger reporting mode

Event trigger

Additional measurement list

Not present

– CHOICE measurement type

Inter-frequency measurement

– Inter-frequency measurement objects list

– Inter-frequency cell removal

Not present

– New inter-frequency info list

– Inter-frequency cell id

Any valid identity other than that of Cell 1

– Frequency Information

Any valid frequency other than that of Cell 1

– Cell info

– Cell individual offset

0

– Reference time difference to cell

Not present

– Read SFN Indicator

FALSE

– CHOICE mode

TDD

– Primary CCPCH Info

– CHOICE Mode

TDD

– CHOICE TDD option

1.28 Mcps TDD

– TSTD indicator

FALSE

– Cell parameters ID

Any value of Cell parameters ID

– SCTD indicator

FALSE

– Primary CCPCH TX power

Not present

– Timeslot list

Not present

– Cell for measurement

Not present

– Inter-frequency measurement quantity

– CHOICE reporting criteria

Inter-frequency reporting criteria

– Filter Coefficient

4

– CHOICE mode

TDD

– Measurement quantity for frequency quality estimate

P-CCPCH RSCP

– Inter-frequency reporting quantity

– UTRAN Carrier RSSI

FALSE

– Frequency quality estimate

FALSE

– Non frequency related quantities

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CHOICE mode

TDD

– Timeslot ISCP reporting indicator

FALSE

– Proposed TGSN reporting indicator

FALSE

– Primary CCPCH RSCP reporting indicator

FALSE

– Pathloss reporting indicator

FALSE

– Measurement validity

CELL_DCH state

– CHOICE report criteria

Inter-frequency measurement reporting criteria

– Parameters required for each events

– Inter-frequency event identity

2D

– Threshold used frequency

-70 dBm

– W used frequency

0

– Hysteresis

2 (1 dB)

– Time to trigger

5000 mSec

– Reporting cell status

Not present

– Maximum number of reported cells

2

– Inter-frequency event identity

2F

– Threshold used frequency

-70 dBm

– W used frequency

0

– Hysteresis

2 (1 dB)

– Time to trigger

5000 mSec

– Reporting cell status

Not present

DPCH compressed mode status info

Not present

MEASUREMENT CONTROL (Step 4) (3.84 Mcps TDD)

Information Element

Value/remark

Release

Measurement identity

10

Measurement command

Setup

Measurement reporting mode

– Measurement reporting transfer mode

Unacknowledged Mode RLC

– Periodic reporting / Event trigger reporting mode

Event trigger

Additional measurement list

Not present

– CHOICE measurement type

Inter-frequency measurement

– Inter-frequency measurement objects list

– Inter-frequency cell removal

Not present

– New inter-frequency info list

– Inter-frequency cell id

Any valid identity other than that of Cell 1

– Frequency Information

Any valid frequency other than that of Cell 1

– Cell info

– Cell individual offset

0

– Reference time difference to cell

Not present

– Read SFN Indicator

FALSE

– CHOICE mode

TDD

– Primary CCPCH Info

– CHOICE Mode

TDD

– CHOICE TDD option

3.84 Mcps TDD

REL-4

– Cell parameters ID

Any value of Cell parameters ID

– SCTD indicator

FALSE

– Primary CCPCH TX power

Not present

– Timeslot list

Not present

– Cell for measurement

Not present

– Inter-frequency measurement quantity

– CHOICE reporting criteria

Inter-frequency reporting criteria

– Filter Coefficient

4

– CHOICE mode

TDD

– Measurement quantity for frequency quality estimate

P-CCPCH RSCP

– Inter-frequency reporting quantity

– UTRAN Carrier RSSI

FALSE

– Frequency quality estimate

FALSE

– Non frequency related quantities

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CHOICE mode

TDD

– Timeslot ISCP reporting indicator

FALSE

– Proposed TGSN reporting indicator

FALSE

– Primary CCPCH RSCP reporting indicator

FALSE

– Pathloss reporting indicator

FALSE

– Measurement validity

CELL_DCH state

– CHOICE report criteria

Inter-frequency measurement reporting criteria

– Parameters required for each events

– Inter-frequency event identity

2D

– Threshold used frequency

-70 dBm

– W used frequency

0

– Hysteresis

2 (1 dB)

– Time to trigger

5000 mSec

– Reporting cell status

Not present

– Inter-frequency event identity

2F

– Threshold used frequency

-70 dBm

– W used frequency

0

– Hysteresis

2 (1 dB)

– Time to trigger

5000 mSec

– Reporting cell status

Not present

DPCH compressed mode status info

Not present

MEASUREMENT CONTROL (Step 4) (7.68 Mcps TDD)

Information Element

Value/remark

Release

Measurement identity

10

Measurement command

Setup

Measurement reporting mode

– Measurement reporting transfer mode

Unacknowledged Mode RLC

– Periodic reporting / Event trigger reporting mode

Event trigger

Additional measurement list

Not present

– CHOICE measurement type

Inter-frequency measurement

– Inter-frequency measurement objects list

– Inter-frequency cell removal

Not present

– New inter-frequency info list

– Inter-frequency cell id

Any valid identity other than that of Cell 1

– Frequency Information

Any valid frequency other than that of Cell 1

– Cell info

– Cell individual offset

0

– Reference time difference to cell

Not present

– Read SFN Indicator

FALSE

– CHOICE mode

TDD

– Primary CCPCH Info

– CHOICE Mode

TDD

– CHOICE TDD option

7.68 Mcps TDD

REL-7

– Cell parameters ID

Any value of Cell parameters ID

– SCTD indicator

FALSE

– Primary CCPCH TX power

Not present

– Timeslot list

Not present

– Cell for measurement

Not present

– Inter-frequency measurement quantity

– CHOICE reporting criteria

Inter-frequency reporting criteria

– Filter Coefficient

4

– CHOICE mode

TDD

– Measurement quantity for frequency quality estimate

P-CCPCH RSCP

– Inter-frequency reporting quantity

– UTRAN Carrier RSSI

FALSE

– Frequency quality estimate

FALSE

– Non frequency related quantities

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CHOICE mode

TDD

– Timeslot ISCP reporting indicator

FALSE

– Proposed TGSN reporting indicator

FALSE

– Primary CCPCH RSCP reporting indicator

FALSE

– Pathloss reporting indicator

FALSE

– Measurement validity

CELL_DCH state

– CHOICE report criteria

Inter-frequency measurement reporting criteria

– Parameters required for each events

– Inter-frequency event identity

2D

– Threshold used frequency

-70 dBm

– W used frequency

0

– Hysteresis

2 (1 dB)

– Time to trigger

5000 mSec

– Reporting cell status

Not present

– Inter-frequency event identity

2F

– Threshold used frequency

-70 dBm

– W used frequency

0

– Hysteresis

2 (1 dB)

– Time to trigger

5000 mSec

– Reporting cell status

Not present

DPCH compressed mode status info

Not present

MEASUREMENT REPORT (Step 5) (FDD)

Information Element

Value/remark

Measurement identity

Check to see if set to 10

Measured results

Check to see if it is absent

Measured results on RACH

Check to see if it is absent

Additional measured results

Check to see if it is absent

Event results

Inter-frequency measurement event results,

– Inter-frequency event identity

2F

MEASUREMENT REPORT (Step 5)( TDD)

Information Element

Value/remark

Measurement identity

Check to see if set to 10

Measured results

Check to see if it is absent

Measured results on RACH

Check to see if it is absent

Additional measured results

Check to see if it is absent

Event results

– CHOICE event results

Check to see if set to Inter-frequency measurement event results,

– Inter-frequency event identity

Check to see if set to 2F

MEASUREMENT REPORT (Step 7) (FDD)

Information Element

Value/remark

Measurement identity

Check to see if set to 10

Measured results

Check to see if it is absent

Measured results on RACH

Check to see if it is absent

Additional measured results

Check to see if it is absent

Event results

Inter-frequency measurement event results,

– Inter-frequency event identity

2D

MEASUREMENT REPORT (Step 7)( TDD)

Information Element

Value/remark

Measurement identity

Check to see if set to 10

Measured results

Check to see if it is absent

Measured results on RACH

Check to see if it is absent

Additional measured results

Check to see if it is absent

Event results

– CHOICE event results

Check to see if set to Inter-frequency measurement event results,

– Inter-frequency event identity

Check to see if set to 2D

8.4.1.26.5 Test Requirement

1. In step 5 the UE shall send MEASUREMENT REPORT message indicating event 2F.

2. In step 7 the UE shall send MEASUREMENT REPORT message indicating event 2D.

8.4.1.27 Measurement Control and Report: UE internal measurement for events 6A and 6B

8.4.1.27.1 Definition

8.4.1.27.2 Conformance requirement

When event 6A is ordered by UTRAN in a measurement control message, the UE shall send a measurement report when the UE transmission power (for TDD within a single TS) becomes larger than a predefined threshold. The corresponding report identifies the threshold that was exceeded.

When event 6B is ordered by UTRAN in a measurement control message, the UE shall send a measurement report when the UE transmission power (for TDD within a single TS) becomes less than a predefined threshold. The corresponding report identifies the threshold that the UE Tx power went below.

Reference

3GPP TS 25.331, clauses 14.6.2.1 and 14.6.2.2.

8.4.1.27.3 Test Purpose

1. To confirm that the UE performs UE internal measurements and reporting for events 6A and 6B, when requested by the UTRAN to do so in the MEASUREMENT CONTROL message.

8.4.1.27.4 Method of test

Initial Condition

System Simulator: 1 cell, cell 1.

UE: CS-DCCH+DTCH_DCH (State 6-9) or PS-DCCH+DTCH_DCH (State 6-10) in cell 1 as specified in clause 7.4 of TS 34.108, depending on the CN domain supported by the UE.

Test Procedure

The UE is in CELL_DCH state in cell 1, after successfully executing procedures P11 or P13 as specified in clause 7.4 of TS 34.108. Next, SS transmits MEASUREMENT CONTROL message to request the UE to perform UE internal measurements and reporting for events 6A and 6B.

SS increases the UE Tx power above the threshold set to event 6A. After ‘time to trigger’ UE sends MEASUREMENT REPORT, triggered by event 6A, to SS.

SS decreases the UE Tx power below the threshold set to event 6B. After ‘time to trigger’ UE sends MEASUREMENT REPORT, triggered by event 6B, to SS. SS calls for generic procedure C.3 to check that UE is in CELL_DCH state.

Expected Sequence

Step

Direction

Message

Comment

UE

SS

1

UE is initially in CELL_DCH state in cell 1.

2

MEASUREMENT CONTROL

SS requests for measurement and reporting of events 6A and 6B.

3

SS sets the UE transmission power above 18 dBm.

4

MEASUREMENT REPORT

UE shall send 6A event measurement report.

5

SS sets the UE transmission power below 15 dBm.

6

MEASUREMENT REPORT

UE shall send 6B event measurement report.

7



CALL C.3

If the test result of C.3 indicates that UE is in CELL_DCH state, the test passes, otherwise it fails.

Specific Message Content

MEASUREMENT CONTROL (Step 2) (FDD)

Information Element

Value/remark

Measurement Identity

5

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Event Trigger Reporting

Additional measurements list

Not Present

CHOICE measurement type

UE internal measurement

– UE internal measurement

– UE internal measurement quantity

Present

-CHOICE mode

FDD

-UE internal measurement quantity

UE Transmitted Power

-Filter coefficient

0

– UE internal reporting quantity

Present

– UE Transmitted Power

TRUE

– CHOICE mode

FDD

– UE Rx-Tx time difference

FALSE

– CHOICE report criteria

UE internal measurement reporting criteria

– Parameters sent for each UE internal

measurement event

-UE internal event identity

6A

-Time-to-trigger

100 milliseconds

-UE Transmitted Power Tx power threshold

18 dBm

-UE internal event identity

6B

-Time-to-trigger

100 milliseconds

-UE Transmitted Power Tx power threshold

15 dBm

DPCH compressed mode status info

Not Present

MEASUREMENT CONTROL (Step 2)( 1.28 Mcps TDD)

Information Element

Value/remark

Measurement Identity

5

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Event Trigger

Additional measurements list

Not Present

CHOICE measurement type

UE internal measurement

– UE internal measurement quantity

-CHOICE mode

TDD

– measurement quantity

UE Transmitted Power

-Filter coefficient

0

– UE internal reporting quantity

– UE Transmitted Power

TRUE

– CHOICE mode

TDD

– CHOICE TDD option

1.28 Mcps TDD

– TADV info

FALSE

– CHOICE report criteria

UE internal measurement reporting criteria

– Parameters sent for each UE internal measurement event

-UE internal event identity

6A

-Time-to-trigger

100 milliseconds

-UE Transmitted Power Tx power threshold

18 dBm

-UE internal event identity

6B

-Time-to-trigger

100 milliseconds

-UE Transmitted Power Tx power threshold

15 dBm

DPCH compressed mode status info

Not Present

MEASUREMENT REPORT (Step 4) (FDD)

Information Element

Value/remark

Measurement identity

Check to see if set to 5

Measured Results

– CHOICE measurement

Check to see if set to "UE Internal measured results"

– UE internal measured results

-CHOICE mode

Check to see if set to "FDD"

UE Transmitted Power

Check to see if present and value is reasonable

Measured Results on RACH

Check to see if this IE is absent

Event results

-CHOICE event result

Check to see if set to "UE internal measurement event results"

-UE internal event identity

Check to see if set to "6A"

-CHOICE mode

Check to see if set to "FDD"

-Primary CPICH info

Check to see if this IE is absent

MEASUREMENT REPORT (Step 4)(1.28Mcps TDD)

Information Element

Value/remark

Measurement identity

Check to see if set to 5

Measured Results

– CHOICE measurement

Check to see if set to "UE Internal measured results"

-CHOICE mode

Check to see if set to "TDD"

UE Transmitted Power

Check to see if present and value is reasonable

Measured Results on RACH

Check to see if this IE is absent

Event results

-CHOICE event result

Check to see if set to "UE internal measurement event results"

-UE internal event identity

Check to see if set to "6A"

MEASUREMENT REPORT (Step 6) (FDD)

Information Element

Value/remark

Measurement identity

Check to see if set to 5

Measured Results

– CHOICE measurement

Check to see if set to "UE Internal measured results"

– UE internal measured results

-CHOICE mode

Check to see if set to "FDD"

UE Transmitted Power

Check to see if present and value is reasonable

Measured Results on RACH

Check to see if this IE is absent

Event results

-CHOICE event result

Check to see if set to "UE internal measurement event results"

-UE internal event identity

Check to see if set to "6B"

-CHOICE mode

Check to see if set to "FDD"

-Primary CPICH info

Check to see if this IE is absent

MEASUREMENT REPORT (Step 6)(1.28 Mcps TDD)

Information Element

Value/remark

Measurement identity

Check to see if set to 5

Measured Results

– CHOICE measurement

Check to see if set to "UE Internal measured results"

-CHOICE mode

Check to see if set to "TDD"

– UE Transmitted Power

Check to see if present and value is reasonable

Measured Results on RACH

Check to see if this IE is absent

Event results

-CHOICE event result

Check to see if set to "UE internal measurement event results"

-UE internal event identity

Check to see if set to "6B"

8.4.1.27.5 Test Requirement

After step 3, the UE shall transmit MEASUREMENT REPORT message, containing measured results for UE transmitted power. The ‘Event results’ IE contains event identity 6A.

After step 5, the UE shall transmit MEASUREMENT REPORT message, containing measured results for UE transmitted power. The ‘Event results’ IE contains event identity 6B.

8.4.1.28 Measurement Control and Report: UE internal measurement for events 6F (FDD) and 6G

8.4.1.28.1 Definition

8.4.1.28.2 Conformance requirement

When event 6F is ordered by UTRAN in a MEASUREMENT CONTROL message, the UE shall send a measurement report message when the UE Rx-Tx time difference becomes larger than the threshold defined by the IE "UE Rx-Tx time difference threshold".

When event 6G is ordered by UTRAN in a MEASUREMENT CONTROL message, the UE shall send a measurement report when the UE Rx-Tx time difference becomes less than the threshold defined by the IE "UE Rx-Tx time difference threshold".

Reference

3GPP TS 25.331, clauses 14.6.2.6 and 14.6.2.7.

8.4.1.28.3 Test Purpose

1. To confirm that the UE performs UE internal measurements and reporting for events 6F and 6G, when requested by the UTRAN to do so in the MEASUREMENT CONTROL message.

8.4.1.28.4 Method of test

Initial Condition

System Simulator: 2 cells – The initial configuration of the cells in the SS shall follow the values indicated in table 6.1.2 of TS 34.108.

UE: CS-DCCH+DTCH_DCH (State 6-9) or PS-DCCH+DTCH_DCH (State 6-10) in cell 1 as specified in clause 7.4 of TS 34.108, depending on the CN domain supported by the UE.

Test Procedure

Table 8.4.1.28 illustrates the downlink power to be applied for the 2 cells at various time instants of the test execution. Columns marked "T0" denote the initial conditions, while columns marked "T1" and "T2" are to be applied subsequently. The exact instants on which these values shall be applied are described in the texts in this clause.

Table 8.4.1.28

Parameter

Unit

Cell 1

Cell 2

T0

T1

T2

T0

T1

T2

UTRA RF Channel Number

Mid Range Test Frequency

Mid Range Test Frequency

CPICH Ec (FDD)

dBm/3.84MHz

-60

-60

-60

-75

-60

-70

The UE is in CELL_DCH state in cell 1, after successfully executing procedures P11 or P13 as specified in clause 7.4 of TS 34.108.

SS configures its downlink transmission power settings according to columns "T1" in table 8.4.128. UE shall be triggered to transmit a MEASUREMENT REPORT message, which includes the primary scrambling code for cell 2.

After the MEASUREMENT REPORT message is received, SS then performs an active set update procedure by sending ACTIVE SET UPDATE REQUEST message on the downlink DCCH. Cell 2 is to be added to the active set, according to the content of this downlink message. The UE shall reply with an ACTIVE SET UPDATE COMPLETE message on the uplink DCCH, and include cell 2 to the active set when the activation time specified has elapsed. SS then configures its downlink transmission power settings according to columns "T2" in table 8.4.1.28.. SS sets the initial timing of cell 2 to be the timing of cell 1 – 5 chips.

Next, SS transmits MEASUREMENT CONTROL message to request the UE to perform UE internal measurements and reporting for events 6F and 6G.

SS adjusts the Tx timing of cell 2 above the threshold set to event 6F. After ‘time to trigger’ UE sends MEASUREMENT REPORT, triggered by event 6F, to SS.

SS adjusts the Tx timing of cell 2 below the threshold set to event 6G. After ‘time to trigger’ UE sends MEASUREMENT REPORT, triggered by event 6G, to SS. SS calls for generic procedure C.3 to check that UE is in CELL_DCH state.

Expected Sequence

Step

Direction

Message

Comment

UE

SS

1

UE is initially in CELL_DCH state in cell 1.

1a

SS configures its downlink transmission power settings according to columns "T1" in table 8.4.1.28.

1b

MEASUREMENT REPORT

See specific message contents for this message.

2

ACTIVE SET UPDATE

SS asks UE to add cell 2 into the active set.

3

ACTIVE SET UPDATE COMPLETE

3a

SS configures its downlink transmission power settings according to columns "T2" in table 8.4.1.28

4

MEASUREMENT CONTROL

SS requests for measurement and reporting of events 6F and 6G.

5

SS switches the Tx timing of Cell 2, with respect to Cell 1 to a delay of – 19 chips.

6

MEASUREMENT REPORT

UE shall send 6F event measurement report.

7

SS switches the Tx timing of Cell 2 with respect to Cell 1 to a delay of 19 chips.

8

MEASUREMENT REPORT

UE shall send 6G event measurement report.

9



CALL C.3

If the test result of C.3 indicates that UE is in CELL_DCH state, the test passes, otherwise it fails.

Specific Message Content

MEASUREMENT REPORT (Step 1b)

Information Element

Value/remark

Message Type

Integrity check info

– Message authentication code

This IE is checked to see if it is present. The value is compared against the XMAC-I value computed by SS. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I.

– RRC Message sequence number

This IE is checked to see if it is present. The value is used by SS to compute the XMAC-I value.

Measurement identity

1

Measured Results

– Intra-frequency measured results

Check to see if measurement results for 2 cells are included (the order in which the different cells are reported is not important)

– Cell measured results

– Cell Identity

Checked that this IE is absent

– Cell synchronisation information

Checked that this IE is absent

– Primary CPICH info

– Primary scrambling code

Refer to clause titled "Default settings for cell No.1 (FDD)" in clause 6.1 of TS 34.108

– CPICH Ec/N0

Checked that this IE is absent

– CPICH RSCP

Checked that this IE is present

– Pathloss

Checked that this IE is absent

– Cell measured results

– Cell Identity

Checked that this IE is absent

– Cell synchronisation information

Checked that this IE is present and includes IE COUNT-C-SFN frame difference

– Primary CPICH info

– Primary scrambling code

Refer to clause titled "Default settings for cell No.2 (FDD)" in clause 6.1 of TS 34.108

– CPICH Ec/N0

Checked that this IE is absent

– CPICH RSCP

Checked that this IE is present

– Pathloss

Checked that this IE is absent

Measured results on RACH

Checked that this IE is absent

Additional measured results

Checked that this IE is absent

Event results

– Intra-frequency measurement event results

– Intra-frequency event identity

1a

– Cell measurement event results

– Primary CPICH info

– Primary scrambling code

Refer to clause titled "Default settings for cell No.2 (FDD)" in clause 6.1 of TS 34.108

ACTIVE SET UPDATE (Step 2)

The contents of ACTIVE SET UPDATE message for this test step is identical to the same message found in Annex A with the following exceptions:

Information Element

Value/remark

Version

RRC transaction identifier

0

Activation Time

[256+Current CFN-[current CFN mod 8 + 8 ]]MOD 256

Radio link addition information

– Primary CPICH Info

– Primary Scrambling Code

Set to same code as assigned for cell 2

– Downlink DPCH info for each RL

– CHOICE mode

FDD

– Primary CPICH usage for channel estimation

P-CPICH can be used.

– DPCH frame offset

Calculated value from Cell synchronisation information

– Secondary CPICH info

Not Present

– DL channelisation code

This IE is repeated for all existing downlink DPCHs allocated to the UE

– Secondary scrambling code

1

– Spreading factor

Reference to TS34.108 clause 6.10 Parameter Set

– Code Number

For each DPCH, assign the same code number in the current code given in cell 1.

– Scrambling code change

Not Present

– TPC Combination Index

0

– SSDT Cell Identity

Not Present

R99 and Rel-4 only

– Close loop timing adjustment mode

Not Present

– TFCI Combining Indicator

FALSE

– SCCPCH information for FACH

Not Present

R99 and Rel-4 only

Radio link removal information

Not Present

ACTIVE SET UPDATE COMPLETE (Step 3)

Information Element

Value/remark

RRC transaction identifier

Check to see if it is set to 0

MEASUREMENT CONTROL (Step 4)

Information Element

Value/remark

Measurement Identity

5

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Event Trigger Reporting

Additional measurements list

Not Present

CHOICE measurement type

UE internal measurement

– UE internal measurement

-UE Internal measurement quantity

Present

– CHOICE mode

FDD

– Measurement quantity

UE Rx-Tx time difference

– Filter coefficient

0

– UE internal reporting quantity

Present

– UE Transmitted Power

FALSE

– CHOICE mode

FDD

– UE Rx-Tx time difference

TRUE

– CHOICE report criteria

UE internal measurement reporting criteria

– Parameters sent for each UE internal

measurement event

-UE internal event identity

6F

-Time-to-trigger

0 milliseconds

-UE Rx-Tx time difference threshold

1037

-UE internal event identity

6G

-Time-to-trigger

0 milliseconds

-UE Rx-Tx time difference threshold

1011

DPCH compressed mode status info

Not Present

MEASUREMENT REPORT (Step 6)

Information Element

Value/remark

Measurement identity

Check to see if set to 5

Measured Results

– CHOICE measurement

Check to see if set to "UE Internal measured results"

– UE internal measured results

-CHOICE mode

Check to see if set to "FDD"

UE Rx-Tx report entries

– Primary CPICH info

-Primary scrambling code

Check to see if set to codes assigned for cell 1 & cell 2. UE may report the measured results for the cells in any order.

-UE Rx-Tx time difference type 1

Check to see if present and value is reasonable

Measured Results on RACH

Check to see if this IE is absent

Event results

-CHOICE event result

Check to see if set to "UE internal measurement event results"

-UE internal event identity

Check to see if set to "6F"

-CHOICE mode

Check to see if set to "FDD"

-Primary CPICH info

-Primary scrambling code

Check to see if set to code assigned for cell 2.

MEASUREMENT REPORT (Step 8)

Information Element

Value/remark

Measurement identity

Check to see if set to 5

Measured Results

– CHOICE measurement

Check to see if set to "UE Internal measured results"

– UE internal measured results

-CHOICE mode

Check to see if set to "FDD"

UE Rx-Tx report entries

– Primary CPICH info

-Primary scrambling code

Check to see if set to codes assigned for cell 1 & cell 2.

UE may report the measured results for the cells in any order.

-UE Rx-Tx time difference type 1

Check to see if present and value is reasonable

Measured Results on RACH

Check to see if this IE is absent

Event results

-CHOICE event result

Check to see if set to "UE internal measurement event results"

-UE internal event identity

Check to see if set to "6G"

-CHOICE mode

Check to see if set to "FDD"

-Primary CPICH info

-Primary scrambling code

Check to see if set to code assigned for cell 2

8.4.1.28.5 Test Requirement

After step 5, the UE shall transmit MEASUREMENT REPORT message, containing measured results for UE Rx-Tx time difference. The ‘Event results’ IE contains event identity 6F.

After step 7, the UE shall transmit MEASUREMENT REPORT message, containing measured results for UE Rx-Tx time difference. The ‘Event results’ IE contains event identity 6G.

8.4.1.28a Measurement Control and Report: UE internal measurement for event 6F (1.28 Mcps TDD)

8.4.1.28a.1 Definition

8.4.1.28a.2 Conformance requirement

When event 6F is ordered by UTRAN in a MEASUREMENT CONTROL message, the UE shall send a MEASUREMENT REPORT message when the absolute value of the difference between the measured TADV and the TADV stored in the variable TRIGGERED_6F_EVENT becomes larger than the threshold defined by the IE " TADV Threshold ".

Reference

3GPP TS 25.331, clauses 14.6.2.6a

8.4.1.28a.3 Test Purpose

1. To confirm that the UE performs UE internal measurements and reporting for event 6F, when requested by the UTRAN to do so in the MEASUREMENT CONTROL message.

8.4.1.28a.4 Method of test

Initial Condition

System Simulator: 1 cell

UE: CS-DCCH+DTCH_DCH (State 6-9) or PS-DCCH+DTCH_DCH (State 6-10) in cell 1 as specified in clause 7.4 of TS 34.108, depending on the CN domain supported by the UE.

Test Procedure

The UE is in CELL_DCH state.

SS transmits MEASUREMENT CONTROL message to request the UE to perform UE internal measurements and reporting for event 6F.

SS adjusts the Tx timing of cell 1 until the time difference indicated by TADV becomes above the threshold set to event 6F. After ‘time to trigger’ UE sends MEASUREMENT REPORT, triggered by event 6F, to SS.

SS calls for generic procedure C.3 to check that UE is in CELL_DCH state.

Expected Sequence

Step

Direction

Message

Comment

UE

SS

1

UE is initially in CELL_DCH state in cell 1.

2

MEASUREMENT CONTROL

SS requests for measurement and reporting of event 6F.

3

SS adjusts the Tx timing of cell 1 until the time difference indicated by TADV becomes above a certain threshold.

4

MEASUREMENT REPORT

UE shall send 6F event measurement report.

5



CALL C.3

If the test result of C.3 indicates that UE is in CELL_DCH state, the test passes, otherwise it fails.

Specific Message Content

MEASUREMENT CONTROL (Step 2)

Information Element

Value/remark

Measurement Identity

5

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Event Trigger

Additional measurements list

Not Present

CHOICE measurement type

UE internal measurement

-UE Internal measurement quantity

– CHOICE mode

TDD

– Measurement quantity

TADV

– Filter coefficient

0

– UE internal reporting quantity

– UE Transmitted Power

FALSE

– CHOICE mode

TDD

– CHOICE TDD option

1.28 Mcps TDD

– TADV info

TRUE

– CHOICE report criteria

UE internal measurement reporting criteria

– Parameters sent for each UE internal measurement event

-UE internal event identity

6F

-Time-to-trigger

0

– TADV threshold

60

DPCH compressed mode status info

Not Present

MEASUREMENT REPORT (Step 4)

Information Element

Value/remark

Measurement identity

Check to see if set to 5

Measured Results

– CHOICE measurement

Check to see if set to "UE Internal measured results"

-CHOICE mode

Check to see if set to "TDD"

– CHOICE TDD option

Check to see if set to “1.28 Mcps TDD”

– TADV

Check to see if present and value is reasonable

Measured Results on RACH

Check to see if this IE is absent

Event results

-CHOICE event result

Check to see if set to "UE internal measurement event results"

-UE internal event identity

Check to see if set to "6F"

8.4.1.28a.5 Test Requirement

After step 3, the UE shall transmit MEASUREMENT REPORT message, containing measured results for TADV. The ‘Event results’ IE contains event identity 6F.

8.4.1.29 Measurement Control and Report: Event based Traffic Volume measurement in CELL_FACH state.

8.4.1.29.1 Definition

8.4.1.29.2 Conformance requirement

Upon reception of a MEASUREMENT CONTROL message the UE shall perform actions specified in TS 25.331 subclause 8.6 unless otherwise specified below.

The UE shall:

1> read the IE "Measurement command";

1> if the IE "Measurement command" has the value "setup":

2> store this measurement in the variable MEASUREMENT_IDENTITY according to the IE "measurement identity", first releasing any previously stored measurement with that identity if that exists;

2> for measurement types "inter-RAT measurement" or "inter-frequency measurement":

2> for measurement type "UE positioning measurement":

2> for any other measurement type:

3> if the measurement is valid in the current RRC state of the UE:

4> begin measurements according to the stored control information for this measurement identity.

For traffic volume measurements in the UE only one quantity is compared with the thresholds. This quantity is Transport Channel Traffic Volume (which equals the sum of Buffer Occupancies of RBs multiplexed onto a transport channel) in number of bytes. Every TTI, UE measures the Transport Channel Traffic Volume for each transport channel and compares it with the configured thresholds. If the monitored Transport Channel Traffic Volume exceeds an absolute threshold, i.e. if TCTV>Reporting threshold, this is an event (event 4a) that could trigger a report. The corresponding report specifies at least which measurement ID the event that triggered the report belongs to.

In CELL_FACH state, the UE shall:

1> transmit a MEASUREMENT REPORT message on the uplink DCCH when the reporting criteria stored in variable MEASUREMENT_IDENTITY are met for any ongoing traffic volume measurement or UE positioning measurement that is being performed in the UE;

1> include a measurement report in the IE "Measured results on RACH", as specified in the IE "Intra-frequency reporting quantity for RACH reporting" and the IE "Maximum number of reported cells on RACH" in System Information Block type 12 (or "System Information Block Type 11" if "System Information Block Type 12" is not being broadcast);

1> include in the IE "Measured results on RACH" all requested reporting quantities for cells for which measurements are reported.

Reference

3GPP TS 25.331, clause 14.4.2.1, 3GPP TS 25.331, clause 8.4.1.3, 8.4.2.2.

8.4.1.29.3 Test Purpose

1. To verify that in CELL_FACH state when event 4a triggered at TVM set up UE sends Measurement Report with correct measurement identity and indication of UL transport channel type, radio bearer identities and corresponding RLC buffer payloads in number of bytes.

2 To verify that in CELL_FACH state when event 4a triggered after TVM set up UE sends Measurement Report with correct measurement identity and indication of UL transport channel type, radio bearer identities and corresponding RLC buffer payloads in number of bytes.

3. To confirm that the UE sends MEASUREMENT REPORT message, with measurement report in IE "Measurement results on RACH" as specified in System Information Block type 12.

8.4.1.29.4 Method of test

Initial Condition

System Simulator: 1 cell

UE: Idle state (State 3 or State 7) as specified in clause 7.4 of TS 34.108.

System Information Block type 11 or 12 does not include Traffic Volume measurement system information.

Test Procedure

The UE is brought to the CELL_FACH state after a successful incoming call attempt. The SS follows the procedure in TS 34.108 clause 7.1.3 (Mobile Terminated), to set up a user RAB, but with the default RAB replaced by the one described in 34.108, clause 6.10.2.4.3.2(for FDD) , clause 6.10.3.4.4.2(for 3.84 Mcps TDD), clause 6.11.5.4.4.2(for 1.28 Mcps TDD) or clause 6.11.6.4.4.2(for 7.68 Mcps TDD): Interactive/Background 32 kbps PS RAB + SRBs for CCCH + SRB for DCCH + SRB for BCCH for DL and 6.10.2.4.4.1: Interactive/Background 32 kbps PS RAB + SRB for CCCH + SRB for DCCH (for FDD), 6.10.2.4.4.1: Interactive/Background 12.8 kbps PS RAB + SRB for CCCH + SRB for DCCH (for 3.84 Mcps TDD), clause 6.11.5.4.5.2 Interactive/Background 32 kbps PS RAB + SRB for CCCH + SRBs for DCCH for UL(for 1.28Mcps TDD) or 6.11.6.4.4.1: Interactive/Background 12.8 kbps PS RAB + SRB for CCCH + SRB for DCCH (for 7.68 Mcps TDD) for DL. The radio bearer is placed into UE test loop mode 1 described in 34.109 clause 5.3. The System Information Block type 12 is modified compared to the default settings so that CPICH RSCP (for FDD) or P-CCPCH RSCP (for TDD) is reported for intra-frequency reporting when transmitting RACH messages. After this modification, SS configures transport channel traffic volume so as to exceed threshold and then sends to UE MEASUREMENT CONTROL message, which includes traffic volume measurement control parameters e.g. uplink transport channel type and reporting threshold. Transport channel traffic volume exceeds threshold and after ‘time to trigger’ UE sends MEASUREMENT REPORT to SS. SS does not respond and after ‘pending time after trigger’ UE sends the same MEASUREMENT REPORT again. SS configures UE’s transport channel load decreases to zero and UE sends no MEASUREMENT REPORT message. SS configures transport channel traffic volume so as to exceed threshold again and after ‘time to trigger’ UE sends MEASUREMENT REPORT message to SS. After ‘pending time after trigger’ UE sends again same MEASUREMENT REPORT message. SS calls for generic procedure C.2 to check that UE is in CELL_FACH state.

Expected Sequence

Step

Direction

Message

Comment

UE

SS

1

PAGING TYPE1

The SS transmits the message, which includes a allocated identity (P-TMSI).

1a

RRC CONNECTION REQUEST

1b

RRC CONNECTION SETUP

1c

RRC CONNECTION SETUP COMPLETE

1d

SERVICE REQUEST

1e

AUTHENTICATION AND CIPHERING REQUEST

1f

AUTHENTICATION AND CIPHERING RESPONSE

1g

SECURITY MODE COMMAND

1h

SECURITY MODE COMPLETE

1i

ACTIVATE RB TEST MODE

TC

1j

ACTIVATE RB TEST MODE COMPLETE

1k

RADIO BEARER SETUP

RRC RAB SETUP

See specific message contents for this message

1l

RADIO BEARER SETUP COMPLETE

1m

CLOSED UE TEST LOOP

TC

UE Test Loop Mode1

1n

CLOSED UE TEST LOOP COMPLETE

TC

1o

MASTER INFORMATION BLOCK, SCHEDULING BLOCK 1,

SYSTEM INFORMATION BLOCK TYPE 12

System Information Block type 12 is different from the default settings (see specific message contents)

1p

SYSTEM INFORMATION CHANGE INDICATION

To notify the modification of SYSTEM INFORMATION BLOCK TYPE 12, this message Is transmitted.

1q

SS configures transport channel traffic volume so as to exceed threshold.

2

MEASUREMENT CONTROL

SS provides Traffic Volume measurement criteria to UE.

3

MEASUREMENT REPORT

UE reports that Traffic Volume measurement event 4A is triggered.

4

MEASUREMENT REPORT

UE repeats message after 1100 ms.

4a

SS configures UE’s transport channel load decreases to zero

4b

SS receive no MEASUREMENT REPORT message.

4c

SS configures transport channel traffic volume so as to exceed threshold

4d

MEASUREMENT REPORT

UE reports that Traffic Volume measurement event 4A is triggered.

4e

MEASUREMENT REPORT

UE repeats message after 1100 ms.

5



CALL C.2

If the test result of C.2 indicates that UE is in CELL_FACH state, the test passes, otherwise it fails.

Specific Message Content

PAGING TYPE 1 (Step 1)

Information Element

Value/remark

Message Type

Paging record list

Only 1 entry

Paging record

CHOICE Used paging identity

CN identity

– Paging cause

Terminating Call with one of the supported services

– CN domain identity

PS Domain

– CHOICE UE Identity

P-TMSI

– p-TMSI

Allocated identity during the attach procedure.

BCCH modification info

Not Present

RRC CONNECTION REQUEST (Step 1a)

Information Element

Value/remark

Message type

Initial UE identity

Same as the IMSI stored in the TEST USIM card, or the registered TMSI or P-TMSI

Establishment Cause

Check to see if it is set to the same value as "Paging Cause" IE in the PAGING TYPE 1 message transmitted on step 1

Protocol Error Indicator

Check to see if it is set to FALSE

Measured results on RACH

Not checked.

System Information Block type 12 (Step 1o) (FDD)

Use the same message sub-type found in clause 6.1 of TS 34.108, with the following exception:

Information Element

Value/remark

FACH measurement occasion info

Not Present

Measurement control system information

– Use of HCS

Not used

– Cell selection and reselection quality measure

CPICH RSCP

– Intra-frequency measurement system information

– Intra-frequency measurement identity

5

– Intra-frequency cell info list

– CHOICE intra-frequency cell removal

Remove no intra-frequency cells

– New intra-frequency cells

– Intra-frequency cell id

1

– Cell info

– Cell individual offset

0 dB

– Reference time difference to cell

Not present

– Read SFN Indicator

TRUE

– CHOICE mode

FDD

– Primary CPICH Info

– Primary Scrambling Code

Set to same code as used for cell 2

– Primary CPICH TX power

Not Present

– TX Diversity Indicator

FALSE

– Cell selection and re-selection info for SIB12

– Qoffset1s,n

0dB

– Qoffset2s,n

Not present

– Maximum allowed UL Tx Power

Reference to table 6.1.1

– HCS neighbouring cell information

Not Present

– CHOICE mode

FDD

– Qqualmin

Reference to table 6.1.1

– Qrxlevmin

Reference to table 6.1.1

– Intra-frequency cell id

2

– Cell info

– Cell individual offset

0 dB

– Reference time difference to cell

Not present

– Read SFN Indicator

TRUE

– CHOICE mode

FDD

– Primary CPICH Info

– Primary Scrambling Code

Set to same code as used for cell 3

– Primary CPICH TX power

Not Present

– TX Diversity Indicator

FALSE

– Cell selection and re-selection info for SIB12

– Qoffset1s,n

0dB

– Qoffset2s,n

Not present

– Maximum allowed UL Tx Power

Reference to table 6.1.1

– HCS neighbouring cell information

Not Present

– CHOICE mode

FDD

– Qqualmin

Reference to table 6.1.1

– Qrxlevmin

Reference to table 6.1.1

– Intra-frequency cell id

3

– Cell info

– Cell individual offset

0 dB

– Reference time difference to cell

Not present

– Read SFN Indicator

TRUE

– CHOICE mode

FDD

– Primary CPICH Info

– Primary Scrambling Code

Set to same code as used for cell 4

– Primary CPICH TX power

Not present

– TX Diversity Indicator

FALSE

– Cell selection and re-selection info for SIB12

– Qoffset1s,n

0dB

– Qoffset2s,n

Not present

– Maximum allowed UL Tx Power

Reference to table 6.1.1

– HCS neighbouring cell information

Not Present

– CHOICE mode

FDD

– Qqualmin

Reference to table 6.1.1

– Qrxlevmin

Reference to table 6.1.1

– Intra-frequency cell id

4

– Cell info

– Cell individual offset

0 dB

– Reference time difference to cell

Not present

– Read SFN Indicator

TRUE

– CHOICE mode

FDD

– Primary CPICH Info

– Primary Scrambling Code

Set to same code as used for cell 5

– Primary CPICH TX power

Not present

– TX Diversity Indicator

FALSE

– Cell selection and re-selection info for SIB12

– Qoffset1s,n

0dB

– Qoffset2s,n

Not present

– Maximum allowed UL Tx Power

Reference to table 6.1.1

– HCS neighbouring cell information

Not Present

– CHOICE mode

FDD

– Qqualmin

Reference to table 6.1.1

– Qrxlevmin

Reference to table 6.1.1

– Intra-frequency Measurement quantity

– Filter Coefficient

Not Present

– Measurement quantity

CPICH RSCP

– Intra-frequency measurement for RACH reporting

– SFN-SFN observed time difference

No report

– Reporting quantity

CPICH RSCP

– Maximum number of reported cells on RACH

Current cell

– Reporting information for state CELL_DCH

– Intra-frequency reporting quantity

– Reporting quantities for active set cells

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CPICH Ec/No reporting indicator

FALSE

– CPICH RSCP reporting indicator

FALSE

– Pathloss reporting indicator

FALSE

– Reporting quantities for monitored set cells

– Cell synchronisation information reporting indicator

TRUE

– Cell identity reporting indicator

FALSE

– CPICH Ec/No reporting indicator

FALSE

– CPICH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting quantities for detected set cells

Not present

– Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged mode RLC

– Periodic Reporting/Event Trigger Reporting Mode

Event trigger

– CHOICE report criteria

Intra-frequency measurement reporting criteria

– Parameters required for each event

– Intra-frequency event identity

1a

– Triggering condition 1

Not Present

– Triggering condition 2

Monitored set cells

– Reporting Range Constant

29 (14.5 dB)

– Cells forbidden to affect reporting range

Not Present

– W

0.0

– Hysteresis

2 (1 dB)

– Threshold used frequency

Not Present

– Reporting deactivation threshold

0

– Replacement activation threshold

Not Present

– Time to trigger

60 ms

– Amount of reporting

Infinity

– Reporting interval

16 seconds

– Reporting Cell Status

– CHOICE reported cell

Report cells within active and/or monitored set on used frequency or within active and/or monitored set on non-used frequency

– Maximum number of reported cells

2

– Inter-frequency measurement system information

Not Present

– Traffic volume measurement system information

Not Present

System Information Block type 12 (Step 1o) (1.28 Mcps TDD)

Use the same message sub-type found in clause 6.1 of TS 34.108, with the following exception:

Information Element

Value/remark

FACH measurement occasion info

Not Present

Measurement control system information

– Use of HCS

Not used

– Cell selection and reselection quality measure

CPICH RSCP

– Intra-frequency measurement system information

– Intra-frequency measurement identity

5

– Intra-frequency cell info list

– CHOICE intra-frequency cell removal

Remove no intra-frequency cells

– New intra-frequency cells

– Intra-frequency cell id

1

– Cell info

– Cell individual offset

0 dB

– Reference time difference to cell

Not present

– Read SFN Indicator

FALSE

– CHOICE mode

TDD

– Primary CCPCH Info

– CHOICE TDD option

1.28 Mcps TDD

– Cell parameters ID

Set to same Cell parameters ID as used for cell 1

– Primary CCPCH TX power

Not Present

– Timeslot list

Not Present

– Cell selection and Re-selection info

Not present

– Intra-frequency Measurement quantity

– Filter Coefficient

Not Present

– CHOICE mode

TDD

– Measurement quantity

P-CCPCH RSCP

– Intra-frequency measurement for RACH reporting

– SFN-SFN observed time difference

No report

– CHOICE mode

TDD

– Reporting quantity

P-CCPCH RSCP

– Maximum number of reported cells on RACH

Current cell

– Reporting information for state CELL_DCH

– Intra-frequency reporting quantity

– Reporting quantities for active set cells

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CHOICE mode

TDD

– Timeslot ISCP reporting indicator

FALSE

– Proposed TGSN reporting indicator

FALSE

– Primary CCPCH RSCP reporting indicator

FALSE

– Pathloss reporting indicator

FALSE

– Reporting quantities for monitored set cells

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CHOICE mode

TDD

– Timeslot ISCP reporting indicator

FALSE

– Proposed TGSN reporting indicator

FALSE

– Primary CCPCH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting quantities for detected set cells

Not present

– Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged mode RLC

– Periodic Reporting/Event Trigger Reporting Mode

Event trigger

– CHOICE report criteria

Intra-frequency measurement reporting criteria

– Parameters required for each event

– Intra-frequency event identity

1g

– Triggering condition 1

Not Present

– Triggering condition 2

Not Present

– Reporting Range Constant

Not Present

– Cells forbidden to affect reporting range

Not Present

– W

Not Present

– Hysteresis

2 (1.0 dB)

– Threshold used frequency

Not Present

– Reporting deactivation threshold

Not Present

– Replacement activation threshold

Not Present

– Time to trigger

60 ms

– Amount of reporting

Infinity

– Reporting interval

16 seconds

– Reporting Cell Status

– CHOICE reported cell

Report cells within active and/or monitored set on used frequency or within virtual active and/or monitored set on non-used frequency

– Maximum number of reported cells

2

– Inter-frequency measurement system information

Not Present

– Traffic volume measurement system information

Not Present

System Information Block type 12 (Step 1o) (3.84 Mcps TDD)

Use the same message sub-type found in clause 6.1 of TS 34.108, with the following exception:

Information Element

Value/remark

FACH measurement occasion info

Not Present

Measurement control system information

– Use of HCS

Not used

– Cell selection and reselection quality measure

CPICH RSCP

– Intra-frequency measurement system information

– Intra-frequency measurement identity

5

– Intra-frequency cell info list

– CHOICE intra-frequency cell removal

Remove no intra-frequency cells

– New intra-frequency cells

– Intra-frequency cell id

1

– Cell info

– Cell individual offset

0 dB

– Reference time difference to cell

Not present

– Read SFN Indicator

FALSE

– CHOICE mode

TDD

– Primary CCPCH Info

– CHOICE TDD option

3.84 Mcps TDD

– Cell parameters ID

Set to same Cell parameters ID as used for cell 1

– Primary CCPCH TX power

Not Present

– Timeslot list

Not Present

– Cell selection and Re-selection info

Not present

– Intra-frequency Measurement quantity

– Filter Coefficient

Not Present

– CHOICE mode

TDD

– Measurement quantity

P-CCPCH RSCP

– Intra-frequency measurement for RACH reporting

– SFN-SFN observed time difference

No report

– CHOICE mode

TDD

– Reporting quantity

P-CCPCH RSCP

– Maximum number of reported cells on RACH

Current cell

– Reporting information for state CELL_DCH

– Intra-frequency reporting quantity

– Reporting quantities for active set cells

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CHOICE mode

TDD

– Timeslot ISCP reporting indicator

FALSE

– Proposed TGSN reporting indicator

FALSE

– Primary CCPCH RSCP reporting indicator

FALSE

– Pathloss reporting indicator

FALSE

– Reporting quantities for monitored set cells

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CHOICE mode

TDD

– Timeslot ISCP reporting indicator

FALSE

– Proposed TGSN reporting indicator

FALSE

– Primary CCPCH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting quantities for detected set cells

Not present

– Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged mode RLC

– Periodic Reporting/Event Trigger Reporting Mode

Event trigger

– CHOICE report criteria

Intra-frequency measurement reporting criteria

– Parameters required for each event

– Intra-frequency event identity

1g

– Triggering condition 1

Not Present

– Triggering condition 2

Not Present

– Reporting Range Constant

Not Present

– Cells forbidden to affect reporting range

Not Present

– W

Not Present

– Hysteresis

2 (1.0 dB)

– Threshold used frequency

Not Present

– Reporting deactivation threshold

Not Present

– Replacement activation threshold

Not Present

– Time to trigger

60 ms

– Amount of reporting

Infinity

– Reporting interval

16 seconds

– Reporting Cell Status

– CHOICE reported cell

Report cells within active and/or monitored set on used frequency or within virtual active and/or monitored set on non-used frequency

– Maximum number of reported cells

2

– Inter-frequency measurement system information

Not Present

– Traffic volume measurement system information

Not Present

System Information Block type 12 (Step 1o) (7.68 Mcps TDD)

Use the same message sub-type found in clause 6.1 of TS 34.108, with the following exception:

Information Element

Value/remark

FACH measurement occasion info

Not Present

Measurement control system information

– Use of HCS

Not used

– Cell selection and reselection quality measure

CPICH RSCP

– Intra-frequency measurement system information

– Intra-frequency measurement identity

5

– Intra-frequency cell info list

– CHOICE intra-frequency cell removal

Remove no intra-frequency cells

– New intra-frequency cells

– Intra-frequency cell id

1

– Cell info

– Cell individual offset

0 dB

– Reference time difference to cell

Not present

– Read SFN Indicator

FALSE

– CHOICE mode

TDD

– Primary CCPCH Info

– CHOICE TDD option

7.68 Mcps TDD

– Cell parameters ID

Set to same Cell parameters ID as used for cell 1

– Primary CCPCH TX power

Not Present

– Timeslot list

Not Present

– Cell selection and Re-selection info

Not present

– Intra-frequency Measurement quantity

– Filter Coefficient

Not Present

– CHOICE mode

TDD

– Measurement quantity

P-CCPCH RSCP

– Intra-frequency measurement for RACH reporting

– SFN-SFN observed time difference

No report

– CHOICE mode

TDD

– Reporting quantity

P-CCPCH RSCP

– Maximum number of reported cells on RACH

Current cell

– Reporting information for state CELL_DCH

– Intra-frequency reporting quantity

– Reporting quantities for active set cells

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CHOICE mode

TDD

– Timeslot ISCP reporting indicator

FALSE

– Proposed TGSN reporting indicator

FALSE

– Primary CCPCH RSCP reporting indicator

FALSE

– Pathloss reporting indicator

FALSE

– Reporting quantities for monitored set cells

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CHOICE mode

TDD

– Timeslot ISCP reporting indicator

FALSE

– Proposed TGSN reporting indicator

FALSE

– Primary CCPCH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting quantities for detected set cells

Not present

– Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged mode RLC

– Periodic Reporting/Event Trigger Reporting Mode

Event trigger

– CHOICE report criteria

Intra-frequency measurement reporting criteria

– Parameters required for each event

– Intra-frequency event identity

1g

– Triggering condition 1

Not Present

– Triggering condition 2

Not Present

– Reporting Range Constant

Not Present

– Cells forbidden to affect reporting range

Not Present

– W

Not Present

– Hysteresis

2 (1.0 dB)

– Threshold used frequency

Not Present

– Reporting deactivation threshold

Not Present

– Replacement activation threshold

Not Present

– Time to trigger

60 ms

– Amount of reporting

Infinity

– Reporting interval

16 seconds

– Reporting Cell Status

– CHOICE reported cell

Report cells within active and/or monitored set on used frequency or within virtual active and/or monitored set on non-used frequency

– Maximum number of reported cells

2

– Inter-frequency measurement system information

Not Present

– Traffic volume measurement system information

Not Present

MASTER INFORMATION BLOCK (Step 1o)

Use the same message sub-type found in clause 6.1 of TS 34.108, with the following exception:

Information Element

Value/remark

MIB Value tag

A valid MIB value tag as defined in TS 25.331 that is different from the previous value

SB 1 Cell Value tag

Set to (Current SB 1 value tag + 1)

SCHEDULING BLOCK 1 (Step 1o)

Information Element

Value/remark

SIB 12 Cell Value tag

Set to (Current SIB 12 value tag + 1)

SYSTEM INFORMATION CHANGE INDICATION (Step 1p)

Information Element

Value/remark

Message Type

BCCH modification info

MIB Value Tag

A valid MIB value tag as defined in TS 25.331 that is different from the previous value

BCCH Modification time

Not Present

MEASUREMENT CONTROL (Step 2)

Information Element

Value/remark

Measurement Identity

15

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Event Trigger

Additional measurements list

Not Present

CHOICE measurement type

Traffic volume measurement

– Traffic volume measurement object

– Uplink transport channel type

RACH

– Traffic volume measurement quantity

– Measurement quantity

RLC buffer payload

– Traffic volume reporting quantity

– RLC Buffer Payload for each RB

TRUE

– Average of RLC Buffer Payload for each RB

FALSE

– Variance of RLC Buffer Payload for each RB

FALSE

– Measurement validity

– UE state

All states except CELL_DCH

CHOICE report criteria

Traffic volume measurement reporting criteria

– Parameters sent for each transport channel

– Parameters required for each event

– Traffic volume event identity

4a

– Reporting threshold

8

– Time to trigger

100

– Pending time after trigger

1000

– Tx interruption after trigger

250

MEASUREMENT REPORT (Step 3, step 4, step 4d and step 4e) (FDD)

The order in which the RBs are reported is not checked.

Information Element

Value/remark

Measurement identity

Check to see if set to 15

Measured Results

– CHOICE measurement

Check to see if set to "Traffic volume measured results list"

– Traffic volume measurement results

– RB Identity

1

– RLC Buffers Payload

Check to see if this IE is present

– Average of RLC Buffer Payload

Check to see if this IE is absent

– Variance of RLC Buffer Payload

Check to see if this IE is absent

– RB Identity

2

– RLC Buffers Payload

Check to see if this IE is present

– Average of RLC Buffer Payload

Check to see if this IE is absent

– Variance of RLC Buffer Payload

Check to see if this IE is absent

– RB Identity

3

– RLC Buffers Payload

Check to see if this IE is present

– Average of RLC Buffer Payload

Check to see if this IE is absent

– Variance of RLC Buffer Payload

Check to see if this IE is absent

– RB Identity

4

– RLC Buffers Payload

Check to see if this IE is present

– Average of RLC Buffer Payload

Check to see if this IE is absent

– Variance of RLC Buffer Payload

Check to see if this IE is absent

– RB Identity

20

– RLC Buffers Payload

Check to see if the value is above the threshold

– Average of RLC Buffer Payload

Check to see if this IE is absent

– Variance of RLC Buffer Payload

Check to see if this IE is absent

Measured Results on RACH

– Measurement result for current cell

Check to see if set to ‘CPICH RSCP’

– CHOICE measurement quantity

– CPICH RSCP

Checked to see if this IE is present and within the acceptable range

Additional Measured results

Not checked

Event Results

– Uplink transport channel type causing the event

Check to see if set to "RACH"

– UL transport channel identity

Check that this IE is absent

– Traffic volume event identity

Check to see if set to "4a"

MEASUREMENT REPORT (Step 3, step 4, step 4d and step 4e) (TDD)

Information Element

Value/remark

Measurement identity

Check to see if set to 15

Measured Results

– CHOICE measurement

Check to see if set to "Traffic volume measured results list"

– Traffic volume measurement results

– RB Identity

1

– RLC Buffers Payload

Check to see if this IE is present

– Average of RLC Buffer Payload

Check to see if this IE is absent

– Variance of RLC Buffer Payload

Check to see if this IE is absent

– RB Identity

2

– RLC Buffers Payload

Check to see if this IE is present

– Average of RLC Buffer Payload

Check to see if this IE is absent

– Variance of RLC Buffer Payload

Check to see if this IE is absent

– RB Identity

3

– RLC Buffers Payload

Check to see if this IE is present

– Average of RLC Buffer Payload

Check to see if this IE is absent

– Variance of RLC Buffer Payload

Check to see if this IE is absent

– RB Identity

4

– RLC Buffers Payload

Check to see if this IE is present

– Average of RLC Buffer Payload

Check to see if this IE is absent

– Variance of RLC Buffer Payload

Check to see if this IE is absent

– RB Identity

20

– RLC Buffers Payload

Check to see if the value is above the threshold

– Average of RLC Buffer Payload

Check to see if this IE is absent

– Variance of RLC Buffer Payload

Check to see if this IE is absent

Measured Results on RACH

– Measurement result for current cell

– CHOICE mode

Check to see if set to’TDD’

– Primary CCPCH RSCP

Checked to see if this IE is present and the value is within an acceptable range

– Measurement results for monitored cells

– CHOICE mode

Check to see if set to’TDD’

– Primary CCPCH RSCP

Checked to see if this IE is absent

Additional Measured results

Not checked

Event Results

CHOICE event result

Check to see if set to’Traffic volume measurement event results’

– Uplink transport channel type causing the event

Check to see if set to "RACH"

– UL transport channel identity

Check to see that is not set

– Traffic volume event identity

Check to see if set to "4a"

8.4.1.29.5 Test Requirement

In step 3 UE sends MEASUREMENT REPORT with correct measurement identity indication. RB identity and RLC buffers payload has reasonable values. The IE "measured results on RACH", containing the measurement value for cell 1’s CPICH RSCP (for FDD) or P-CCPCH RSCP (for TDD) shall be included in this message.

In step 4, 4d and 4e UE repeats message sent in step 3.

After step 3 UE is not allowed to send user data during the ‘Tx interruption after trigger’ timer is running.

8.4.1.30 Measurement Control and Report: Event based Traffic Volume measurement in CELL_DCH state.

8.4.1.30.1 Definition

8.4.1.30.2 Conformance requirement

Upon reception of a MEASUREMENT CONTROL message the UE shall perform actions specified in TS 25.331 subclause 8.6 unless otherwise specified below.

The UE shall:

1> read the IE "Measurement command";

1> if the IE "Measurement command" has the value "setup":

2> store this measurement in the variable MEASUREMENT_IDENTITY according to the IE "measurement identity", first releasing any previously stored measurement with that identity if that exists;

2> for measurement types "inter-RAT measurement" or "inter-frequency measurement":

2> for measurement type "UE positioning measurement":

2> for any other measurement type:

3> if the measurement is valid in the current RRC state of the UE:

4> begin measurements according to the stored control information for this measurement identity.

For traffic volume measurements in the UE only one quantity is compared with the thresholds. This quantity is Transport Channel Traffic Volume (which equals the sum of Buffer Occupancies of RBs multiplexed onto a transport channel) in number of bytes. Every TTI, UE measures the Transport Channel Traffic Volume for each transport channel and compares it with the configured thresholds.

If the monitored Transport Channel Traffic Volume exceeds an absolute threshold, i.e. if TCTF>Reporting threshold, this is an event (event 4a) that could trigger a report. The corresponding report specifies at least which measurement ID the event that triggered the report belongs to.

If the monitored Transport Channel Traffic Volume becomes smaller than an absolute threshold, i.e. if TCTF<Reporting threshold, this is an event (4b) that could trigger a report. The corresponding report specifies at least which measurement ID the event that triggered the report belongs to.

Reference

3GPP TS 25.331, clause 14.4.2.2, 3GPP TS 25.331, clause 8.4.1.3.

8.4.1.30.3 Test Purpose

1. To verify that in CELL_DCH state when event 4a or 4b triggered at setup TVM UE sends RRC: Measurement Report with correct measurement identity and indication of uplink transport channel type and identity, radio bearer identities and corresponding RLC buffer payloads in number of bytes.

2. To verify that in CELL_DCH state when event 4a or 4b triggered after setup TVM UE sends RRC: Measurement Report with correct measurement identity and indication of uplink transport channel type and identity, radio bearer identities and corresponding RLC buffer payloads in number of bytes.

8.4.1.30.4 Method of test

Initial Condition

System Simulator: 1 cell

UE: Idle state (State 3 or State 7) as specified in clause 7.4 of TS 34.108.

System Information Block type 11 nor 12 does not include Traffic Volume measurement system information.

Test Procedure

The UE is brought to the CELL_DCH state after a successful incoming call attempt. The SS follows the procedure in TS 34.108 clause 7.1.3 (Mobile Terminated), to set up a user RAB, but with the default RAB replaced by the one described in 34.108, clause 6.10.2.4.1.26: Interactive or background / UL: 64 DL: 64 kbps / PS RAB + UL: 3.4 DL: 3.4 kbps SRBs for DCCH. The SS limits the UE allowed Uplink transport format combinations according to the ‘Restricted UL TFCIs’, using the RRC Transport Format Combination control procedure. The radio bearer is placed into UE test loop mode 1 described in TS 34.109 clause 5.3. SS configures UE’s transport channel traffic volume to exceeds threshold. SS sends to UE RRC: MEASUREMENT CONTROL messages, which includes in addition to measurement identity traffic volume measurement control parameters e.g. uplink transport channel type and identity and reporting threshold for events 4a, and after ‘time to trigger’ UE sends RRC: MEASUREMENT REPORT message to SS. SS does not respond and after ‘pending time after trigger’ UE sends again same RRC: MEASUREMENT REPORT message. SS configures UE’s transport channel load decreases to zero and sends UE RRC: MEASUREMENT CONTROL messages, which includes in addition to measurement identity traffic volume measurement control parameters e.g. uplink transport channel type and identity and reporting threshold for event 4b. Event 4b triggers and after ‘time to trigger’ UE sends RRC: MEASUREMENT REPORT message to SS. SS does not respond and after ‘pending time after trigger’ UE sends again same RRC: MEASUREMENT REPORT message. SS increases transport channel traffic volume to exceeds threshold. Event 4a is triggered and after ‘time to trigger’ UE sends RRC: MEASUREMENT REPORT message to SS. SS decreases transport channel traffic volume to zero. Event 4b is triggered and after ‘time to trigger’ UE sends RRC: MEASUREMENT REPORT message to SS. SS calls for generic procedure C.3 to check that UE is in CELL_DCH state.

Expected Sequence

Step

Direction

Message

Comment

UE

SS

1

PAGING TYPE1

The SS transmits the message, which includes a allocated identity (P-TMSI).

1a

RRC CONNECTION REQUEST

1b

RRC CONNECTION SETUP

1c

RRC CONNECTION SETUP COMPLETE

1d

SERVICE REQUEST

1e

AUTHENTICATION AND CIPHERING REQUEST

1f

AUTHENTICATION AND CIPHERING RESPONSE

1g

SECURITY MODE COMMAND

1h

SECURITY MODE COMPLETE

1i

ACTIVATE RB TEST MODE

TC

1j

ACTIVATE RB TEST MODE COMPLETE

1k

RADIO BEARER SETUP

RRC RAB SETUP

See specific message contents for this message

1l

RADIO BEARER SETUP COMPLETE

1la

TRANSPORT FORMAT COMBINATION CONTROL (DCCH)

The SS transmits the message, to setup the needed traffic for the test purpose.

1m

CLOSED UE TEST LOOP

TC

UE Test Loop Mode1

1n

CLOSED UE TEST LOOP COMPLETE

TC

1o

SS configures transport channel traffic volume so as to exceed threshold

2

MEASUREMENT CONTROL

SS provides Traffic Volume measurement criteria (event 4a) to UE.

3

Void

4

MEASUREMENT REPORT

UE’s transport channel is loaded. UE reports that Traffic Volume measurement event 4A is triggered.

5

MEASUREMENT REPORT

UE repeats message after 2100 ms.

5a

UE’s transport channel traffic volume decreases to zero.

5b

MEASUREMENT CONTROL

SS provides Traffic Volume measurement criteria (event 4b) to UE.

6

MEASUREMENT REPORT

UE reports that Traffic Volume measurement event 4B is triggered.

7

MEASUREMENT REPORT

UE repeats message after 2100 ms.

7a

SS increases transport channel traffic volume so as to exceed threshold

7b

MEASUREMENT REPORT

IE "Measurement Identity" is set to "15".

7c

UE’s transport channel traffic volume decreases to zero.

7d

MEASUREMENT REPORT

IE "Measurement Identity" is set to "14".

8



CALL C.3

If the test result of C.3 indicates that UE is in CELL_DCH state, the test passes, otherwise it fails.

Specific Message Content

PAGING TYPE 1 (Step 1)

Information Element

Value/remark

Message Type

Paging record list

Only 1 entry

Paging record

CHOICE Used paging identity

CN identity

– Paging cause

Terminating Call with one of the supported services

– CN domain identity

PS Domain

– CHOICE UE Identity

p-TMSI

– p-TMSI

Allocated identity during the attach procedure

BCCH modification info

Not Present

RRC CONNECTION REQUEST (Step 1a)

Information Element

Value/remark

Message type

Initial UE identity

Same as the IMSI stored in the TEST USIM card, or the registered TMSI or P-TMSI

Establishment Cause

Check to see if it is set to the same value as "Paging Cause" IE in the PAGING TYPE 1 message transmitted on step 1

Protocol Error Indicator

Check to see if it is set to FALSE

Measured results on RACH

Not checked.

TRANSPORT FORMAT COMBINATION CONTROL (Step 1 la )

Information Element

Value/remark

TrCH information elements

-DPCH/PUSCH TFCS uplink in uplink

– Allowed TFI

0,1,5,6

MEASUREMENT CONTROL (Step 2)

Information Element

Value/remark

Measurement Identity

15

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Event Trigger

Additional measurements list

Not Present

CHOICE measurement type

– Traffic volume measurement objects

– Uplink transport channel type

DCH

– UL target transport channel ID

1

– Traffic volume measurement quantity

– Measurement quantity

RLC buffer payload

– Traffic volume reporting quantity

– RLC Buffer Payload for each RB

TRUE

– Average of RLC Buffer Payload for each RB

FALSE

– Variance of RLC Buffer Payload for each RB

FALSE

– Measurement validity

– UE state

CELL_DCH

– Traffic volume measurement reporting criteria

– Uplink transport channel type

Not present

– UL Transport Channel ID

Not present

– Traffic volume event identity

4a

– Reporting threshold

256

– Time to trigger

100

– Pending time after trigger

2000

– Tx interruption after trigger

Not present

MEASUREMENT CONTROL (Step 5b)

Information Element

Value/remark

Measurement Identity

14

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Event Trigger

Additional measurements list

Not Present

CHOICE measurement type

– Traffic volume measurement objects

– Uplink transport channel type

DCH

– UL target transport channel ID

1

– Traffic volume measurement quantity

– Measurement quantity

RLC buffer payload

– Traffic volume reporting quantity

– RLC Buffer Payload for each RB

TRUE

– Average of RLC Buffer Payload for each RB

FALSE

– Variance of RLC Buffer Payload for each RB

FALSE

– Measurement validity

– UE state

CELL_DCH

– Traffic volume measurement reporting criteria

– Uplink transport channel type

Not present

– UL Transport Channel ID

Not present

– Traffic volume event identity

4b

– Reporting threshold

32

– Time to trigger

100

– Pending time after trigger

2000

– Tx interruption after trigger

Not present

MEASUREMENT REPORT (Step 4, step 5 and step 7b)

Information Element

Value/remark

Measurement identity

Check to see if set to 15

Measured Results

– CHOICE measurement

Check to see if set to "Traffic volume measured results list"

– Traffic volume measurement results

– RB Identity

20

– RLC Buffers Payload

Check to see if the value is above the threshold

– Average of RLC Buffer Payload

Check to see if this IE is absent

– Variance of RLC Buffer Payload

Check to see if this IE is absent

Measured Results on RACH

Not checked

Additional Measured results

Not checked

Event Results

– Uplink transport channel type causing the

Check to see if set to "DCH"

event

– UL transport channel identity

Check to see if set to "1"

– Traffic volume event identity

Check to see if set to "4a"

MEASUREMENT REPORT (Step 6, step 7 and 7d)

Information Element

Value/remark

Measurement identity

Check to see if set to 14

Measured Results

– CHOICE measurement

Check to see if set to "Traffic volume measured results list"

– Traffic volume measurement results

– RB identity

Check that value is 20

– RLC buffers payload

Check that value is below the threshold

Measured Results on RACH

Not checked

Additional Measured results

Not checked

Event Results

– Uplink transport channel type causing the

Check to see if set to "DCH"

event

– UL transport channel identity

Check to see if set to "1"

– Traffic volume event identity

Check to see if set to "4b"

8.4.1.30.5 Test Requirement

In steps 4, 5, 6, 7, 7b and 7d UE sends RRC: MEASUREMENT REPORT with correct measurement identity indication. RB identity and RLC buffers payload has correct values. Measurement identity, transport channel type, transport channel identity and event identity has to match with set values.

8.4.1.31 Measurement Control and Report: Inter-RAT measurement in CELL_DCH state.

8.4.1.31.1 Definition

8.4.1.31.2 Conformance requirement

A UE supporting both FDD (or TDD) and GSM shall be able to perform the GSM RSSI measurement and the GSM Initial BSIC identification measurement.

If, according to its capabilities, the UE requires compressed mode to perform GSM RSSI measurements, the UE shall perform GSM RSSI measurements in the gaps of a compressed mode pattern sequence specified for GSM RSSI measurement purpose.

If, according to its capabilities, the UE requires compressed mode to perform GSM Initial BSIC identification measurements, the UE shall perform GSM Initial BSIC identification in a compressed mode pattern sequence specified for Initial BSIC identification measurement purpose.

Reference

3GPP TS 25.133, clause 8.1.2.5; 3GPP TS 25.331, clauses 8.6.7.6, 14.3.2.

8.4.1.31.3 Test Purpose

Purpose of this test is to verify that UE is capable to perform GSM RSSI and GSM Initial BSIC identification measurements.

8.4.1.31.4 Method of test

Initial Condition

System Simulator: 1 UTRAN FDD cell (or TDD cell) and 2 GSM cells.

Parameter

Unit

Cell 1 (GSM)

Cell 2 (GSM)

Test Channel

#

1

2

RF Signal Level

dBm

-70

-85

BCCH ARFCN

#

Value according to the GSM band under test (see 3GPP 34.123-1 table 6.5 for details on the ARFCN)

Value according to the GSM band under test (see 3GPP 34.123-1 table 6.5 for details on the ARFCN)

CELL identity

#

0

1

BSIC

#

BSIC1

BSIC2

UE: CELL_DCH state, state 6-9 as specified in clause 7.4 of TS 34.108.

System Information Block type 11 nor 12 does not include Inter-RAT measurement system information.

Related ICS/IXIT statements

– Compressed mode required yes/no

– UE supports GSM-P, GSM-E, GSM-DCS, GSM-450, GSM-480, GSM-PCS, GSM-850.

Test Procedure

The UE is brought to the CELL_DCH state after a successful outgoing call attempt. If the UE requires compressed mode (refer ICS/IXIT), the SS sends a PHYSICAL CHANNEL RECONFIGURATION message to the UE to configure the compressed mode pattern sequence parameters. Two compressed mode patterns are configured, according to the message specified below. When the PHYSICAL CHANNEL RECONFIGURATION COMPLETE is received from the UE, the SS sends a MEASUREMENT CONTROL message.

The first RRC: MEASUREMENT CONTROL message is used to provide measurement control parameters (GSM RSSI) to the UE and to start compressed mode for the measurement if required according to the UE capabilities. The UE replies according to request by sending RRC: MEASUREMENT REPORT messages periodically to SS. Reporting period is 4000 ms.

After two RRC: MEASUREMENT REPORT messages, the SS sends a second RRC: MEASUREMENT CONTROL message to start GSM Initial BSIC identification measurement. The UE replies similarly as in GSM RSSI measurement case but now with a period of 12000ms.

The SS calls for generic procedure C.3 to check that UE is in CELL_DCH state.

Expected Sequence

Step

Direction

Message

Comment

UE

SS

1

The UE is brought to the CELL_DCH state in the cell 1. If the UE does not require compressed mode (refer ICS/IXIT), then goto step 4.

2

PHYSICAL CHANNEL RECONFIGURATION

Compressed mode pattern sequence parameters are loaded to UE.

3

PHYSICAL CHANNEL RECONFIGURATION COMPLETE

4

MEASUREMENT CONTROL

SS provides GSM RSSI measurement control parameters to UE. If the UE requires compressed mode (refer ICS/IXIT), compressed mode for GSM RSSI measurement is started.

5

MEASUREMENT REPORT

UE reports measurement results of GSM RSSI measurement to SS.

6

MEASUREMENT REPORT

Next periodical measurement report.

7

MEASUREMENT CONTROL

SS provides GSM Initial BSIC identification measurement control parameters to UE. If the UE requires compressed mode (refer ICS/IXIT),compressed mode for GSM Initial BSIC identification measurement is started.

8

MEASUREMENT REPORT

UE reports measurement results of GSM Initial BSIC identification measurement to SS.

9

MEASUREMENT REPORT

Next periodical measurement report.

10



CALL C.3

If the test result of C.3 indicates that UE is in CELL_DCH state, the test passes, otherwise it fails.

Specific Message Content

PHYSICAL CHANNEL RECONFIGURATION (Step 2)

Use the same message sub-type as in TS 34.108 titled "Speech in CS", with Scrambling code change set to Default1 and with the following exceptions:

Information Element

Value/remark

Version

Downlink information common for all radio links

– DPCH compressed mode info

– TGPSI

1

– TGPS Status Flag

Deactivate

– TGCFN

Not present

– Transmission gap pattern sequence configuration parameters

– TGMP

GSM Carrier RSSI Measurement

– TGPRC

Infinity

– TGSN

4

– TGL1

7

– TGL2

Not present

– TGD

undefined

– TGPL1

12

– TGPL2

Not present

R99 and REL-4 only

– RPP

Mode 0

– ITP

Mode 0

CHOICE UL/DL Mode

UL&DL or UL-only or DL-only (depends on UE’s Measurement capability)

– Downlink compressed mode method

SF/2

– Uplink compressed mode method

SF/2

– Downlink frame type

A

– DeltaSIR1

20 (2.0)

– DeltaSIRAfter1

10 (1.0)

– DeltaSIR2

Not Present

– DeltaSIR2After2

Not Present

– N identify abort

Not Present

– T Reconfirm abort

Not Present

– TGPSI

2

– TGPS Status Flag

Deactivate

– TGCFN

Not present

– Transmission gap pattern sequence configuration parameters

– TGMP

GSM Initial BSIC identification

– TGPRC

Infinity

– TGSN

4

– TGL1

7

– TGL2

Not present

– TGD

undefined

– TGPL1

8

– TGPL2

Not present

R99 and REL-4 only

– RPP

Mode 0

– ITP

Mode 0

CHOICE UL/DL Mode

UL&DL or UL-only or DL-only (depends on UE’s Measurement capability)

– Downlink compressed mode method

SF/2

– Uplink compressed mode method

SF/2

– Downlink frame type

A

– DeltaSIR1

20 (2.0)

– DeltaSIRAfter1

10 (1.0)

– DeltaSIR2

Not Present

– DeltaSIR2After2

Not Present

– N identify abort

128

– T Reconfirm abort

Not Present

Downlink information per radio link list

– Choice mode

FDD

– Primary CPICH info

– Primary scrambling code

Ref. to the Default setting in clause 6.1 (FDD)

– PDSCH with SHO DCH info

Not Present

R99 and Rel-4 only

– PDSCH code mapping

Not Present

R99 and Rel-4 only

– Serving HS-DSCH radio link indicator

FALSE

Rel-5

– Serving E-DCH radio link indicator

FALSE

Rel-6

– Downlink DPCH info for each RL

– CHOICE mode

FDD

– Primary CPICH usage for channel estimation

Primary CPICH may be used

– DPCH frame offset

Set to value : Default DPCH Offset Value (as currently stored in SS) mod 38 400

– Secondary CPICH info

Not Present

– DL channelisation code

– Secondary scrambling code

5

– Spreading factor

Reference to clause 6.10 Parameter Set

– Code number

0

– Scrambling code change

Set to value Default1: No code change (if the UE has a compressed mode pattern sequence configured in variable TGPS_IDENTITY or included in the message including IE "Downlink DPCH info for each RL", which is using compressed mode method "SF/2")

– TPC combination index

0

– SSDT Cell Identity

Not Present

R99 and Rel-4 only

– Closed loop timing adjustment mode

Not Present

– E-AGCH Info

Not Present

Rel-6

– E-HICH Information

Not Present

Rel-6

– E-RGCH Information

Not Present

Rel-6

– SCCPCH information for FACH

Not Present

R99 and Rel-4 only

MEASUREMENT CONTROL (Step 4)(FDD)

Information Element

Value/remark

Measurement Identity

15

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Periodical reporting

Additional measurements list

Not Present

CHOICE measurement type

– inter-RAT measurement

– inter-RAT measurement object list

CHOICE Inter-RAT Cell Removal

Remove no inter-RAT cells

– New inter-RAT cells

– inter-RAT cell id

0

CHOICE Radio Access Technology

GSM

– Cell individual offset

0

– Cell selection and re-selection info

Not present

– BSIC

BSIC1

– Band indicator

GSM/DCS-1800 or GSM/PCS-1900 (dependent on band used)

– BCCH ARFCN

Value according to the GSM band under test (see 3GPP 34.123-1 table 6.5 for details on the ARFCN)

– inter-RAT cell id

1

CHOICE Radio Access Technology

GSM

– Cell individual offset

0

– Cell selection and re-selection info

Not present

– BSIC

BSIC2

– Band indicator

GSM/DCS-1800 or GSM/PCS-1900 (dependent on band used)

– BCCH ARFCN

Value according to the GSM band under test (see 3GPP 34.123-1 table 6.5 for details on the ARFCN)

– Cell for measurement

Not present

– inter-RAT measurement quantity

– Measurement quantity for UTRAN quality estimate

Not present

CHOICE system

GSM

– Measurement quantity

GSM carrier RSSI

– Filter coefficient

0

– BSIC verification required

not required

– inter-RAT reporting quantity

UTRAN estimated quality

FALSE

CHOICE system

GSM

– Observed time difference to GSM cell reporting indicator

FALSE

– GSM carrier RSSI reporting indicator

TRUE

– Reporting cell status

CHOICE reported cell

– Reported cells within active set or within

virtual active set or of the other RAT

– Maximum number of reported cells

6

CHOICE report criteria

– Periodical reporting criteria

– Amount of reporting

infinity

– Reporting interval

4000

Physical channel information elements

– DPCH compressed mode status info

If the UE requires compressed mode (refer ICS/IXIT), this IE is present and contains the IEs as follows. If the UE does not require compressed mode (refer ICS/IXIT), this IE is not present.

– TGPS reconfiguration CFN

(Current CFN + (256 – TTI/10msec))mod 256

– Transmission gap pattern sequence

– TGPSI

1

– TGPS status flag

Activate

– TGCFN

(Current CFN + (256 – TTI/10msec))mod 256

MEASUREMENT CONTROL (Step 4)(TDD)

Information Element

Value/remark

Measurement Identity

15

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Periodical reporting

Additional measurements list

Not Present

CHOICE measurement type

– inter-RAT measurement

– inter-RAT measurement object list

CHOICE Inter-RAT Cell Removal

Remove no inter-RAT cells

– New inter-RAT cells

– inter-RAT cell id

0

CHOICE Radio Access Technology

GSM

– Cell individual offset

0

– Cell selection and re-selection info

Not present

– BSIC

BSIC1

– Band indicator

GSM/DCS-1800 or GSM/PCS-1900 (dependent on band used)

– BCCH ARFCN

Value according to the GSM band under test (see 3GPP 34.123-1 table 6.5 for details on the ARFCN)

– inter-RAT cell id

1

CHOICE Radio Access Technology

GSM

– Cell individual offset

0

– Cell selection and re-selection info

Not present

– BSIC

BSIC2

– Band indicator

GSM/DCS-1800 or GSM/PCS-1900 (dependent on band used)

– BCCH ARFCN

Value according to the GSM band under test (see 3GPP 34.123-1 table 6.5 for details on the ARFCN)

– Cell for measurement

Not present

– inter-RAT measurement quantity

– Measurement quantity for UTRAN quality estimate

Not present

CHOICE system

GSM

– Measurement quantity

GSM carrier RSSI

– Filter coefficient

0

– BSIC verification required

not required

– inter-RAT reporting quantity

UTRAN estimated quality

FALSE

CHOICE system

GSM

– Observed time difference to GSM cell reporting indicator

FALSE

– GSM carrier RSSI reporting indicator

TRUE

– Reporting cell status

CHOICE reported cell

– Reported cells within active set or within

virtual active set or of the other RAT

– Maximum number of reported cells

6

CHOICE report criteria

– Periodical reporting criteria

– Amount of reporting

infinity

– Reporting interval

4000

MEASUREMENT REPORT, if the UE requires compressed mode (refer ICS/IXIT) (Step 5 and step 6)

Information Element

Value/remark

Version

Measurement identity

Check to see if set to 15

Measured Results

– CHOICE measurement

Check to see if set to "Inter-RAT measured results list"

– Inter-RAT measured result list

– CHOICE system

GSM

– Measured GSM cells

– GSM carrier RSSI

Check to see if present

CHOICE BSIC

Check to see if present

– Observed time difference to GSM cell

Check that not present

R99 and Rel-4 only

– GSM carrier RSSI

Check to see if present

CHOICE BSIC

Check to see if present

– Observed time difference to GSM cell

Check that not present

R99 and Rel-4 only

Measured results on RACH

Check that not present

Additional Measured results

Check that not present

Event results

Check that not present

MEASUREMENT REPORT, if the UE doesn’t requires compressed mode (refer ICS/IXIT) (Step 5 and step 6)

Information Element

Value/remark

Version

Measurement identity

Check to see if set to 15

Measured Results

– CHOICE measurement

Check to see if set to "Inter-RAT measured results list"

– Inter-RAT measured result list

– CHOICE system

GSM

– Measured GSM cells

– GSM carrier RSSI

Check to see if present

CHOICE BSIC

verified BSIC

– Inter-RAT cell id

Check that is set to "0"

– Observed time difference to GSM cell

Check that not present

R99 and Rel-4 only

– GSM carrier RSSI

Check to see if present

CHOICE BSIC

verified BSIC

– Inter-RAT cell id

Check that is set to "1"

– Observed time difference to GSM cell

Check that not present

R99 and Rel-4 only

Measured results on RACH

Check that not present

Additional Measured results

Check that not present

Event results

Check that not present

MEASUREMENT REPORT (1.28Mcps TDD) (Step 5 and step 6)

Information Element

Value/remark

Version

Measurement identity

Check to see if set to 15

Measured Results

Check that not present

Measured results on RACH

Check that not present

Additional Measured results

Check that not present

Non Critical Extensions

– Additional Measured results – LCR

– CHOICE measurement

Check to see if set to "Inter-RAT measured results list"

– Inter-RAT measured result list

– CHOICE system

GSM

– Measured GSM cells

– GSM carrier RSSI

Check to see if present

CHOICE BSIC

Check to see if present

– Observed time difference to GSM cell

Check that not present

R99 and Rel-4 only

– GSM carrier RSSI

Check to see if present

CHOICE BSIC

Check to see if present

– Observed time difference to GSM cell

Check that not present

R99 and Rel-4 only

Event results

Check that not present

MEASUREMENT CONTROL (Step 7)

Information Element

Value/remark

Measurement Identity

15

Measurement Command

Modify

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Periodical reporting

Additional measurements list

Not Present

CHOICE measurement type

– inter-RAT measurement

– inter-RAT measurement object list

Not present

– inter-RAT measurement quantity

– Measurement quantity for UTRAN quality estimate

Not present

CHOICE system

GSM

– Measurement quantity

GSM carrier RSSI

– Filter coefficient

0

– BSIC verification required

required

– inter-RAT reporting quantity

UTRAN estimated quality

FALSE

CHOICE system

GSM

– Observed time difference to GSM

FALSE

cell reporting indicator

– GSM carrier RSSI reporting indicator

TRUE

– Reporting cell status

CHOICE reported cell

– Reported cells within active set or within

virtual active set or of the other RAT

– Maximum number of reported cells

6

CHOICE report criteria

– Periodical reporting criteria

– Amount of reporting

infinity

– Reporting interval

12000

Physical channel information elements

– DPCH compressed mode status info

If the UE requires compressed mode (refer ICS/IXIT), this IE is present and contains the IEs as follows. If the UE does not require compressed mode (refer ICS/IXIT), this IE is not present.

– TGPS reconfiguration CFN

(Current CFN + (256 – TTI/10msec))mod 256

– Transmission gap pattern sequence

– TGPSI

1

– TGPS status flag

Deactivate

– TGCFN

Not present

– TGPSI

2

– TGPS status flag

Activate

– TGCFN

(Current CFN + (256 – TTI/10msec))mod 256

MEASUREMENT REPORT, if the UE requires compressed mode (refer ICS/IXIT) (Step 8)

EITHER

Information Element

Value/remark

Version

Measurement identity

Check to see if set to 15

Measured Results

– CHOICE measurement

Check to see if set to "Inter-RAT measured results list"

– Inter-RAT measured result list

– CHOICE system

GSM

– Measured GSM cells

– GSM carrier RSSI

Not checked

CHOICE BSIC

Verified BSIC

– Inter-RAT cell id

Check that is set to "0"

– Observed time difference to GSM cell

Check that not present

R99 and Rel-4 only

Measured results on RACH

Check that not present

Additional Measured results

Check that not present

Event results

Check that not present

OR

Information Element

Value/remark

Version

Measurement identity

Check to see if set to 15

Measured Results

– CHOICE measurement

Check to see if set to "Inter-RAT measured results list"

– Inter-RAT measured result list

– CHOICE system

GSM

– Measured GSM cells

– GSM carrier RSSI

Not checked

CHOICE BSIC

Verified BSIC

– Inter-RAT cell id

Check that is set to "0" or “1”

– Observed time difference to GSM cell

Check that not present

R99 and Rel-4 only

– GSM carrier RSSI

Not checked

CHOICE BSIC

Verified BSIC

– Inter-RAT cell id

Check that is set to "1" or “0” (the cell id shall be different from the first reported cell id)

– Observed time difference to GSM cell

Check that not present

R99 and Rel-4 only

Measured results on RACH

Check that not present

Additional Measured results

Check that not present

Event results

Check that not present

MEASUREMENT REPORT, if the UE does not require compressed mode (refer ICS/IXIT) (Step 8)

Information Element

Value/remark

Version

Measurement identity

Check to see if set to 15

Measured Results

– CHOICE measurement

Check to see if set to "Inter-RAT measured results list"

– Inter-RAT measured result list

– CHOICE system

GSM

– Measured GSM cells

– GSM carrier RSSI

Check to see if present

CHOICE BSIC

Verified BSIC

– Inter-RAT cell id

Check that is set to "0"

– Observed time difference to GSM cell

Check that not present

R99 and Rel-4 only

– GSM carrier RSSI

Check to see if present

CHOICE BSIC

Verified BSIC

– Inter-RAT cell id

Check that is set to "1"

– Observed time difference to GSM cell

Check that not present

R99 and Rel-4 only

Measured results on RACH

Check that not present

Additional Measured results

Check that not present

Event results

Check that not present

MEASUREMENT REPORT (Step 8) (1.28 Mcps TDD)

Information Element

Value/remark

Version

Measurement identity

Check to see if set to 15

Measured Results

Check that not present

Measured results on RACH

Check that not present

Additional Measured results

Check that not present

Non Critical Extensions

– Additional Measured results – LCR

– CHOICE measurement

Check to see if set to "Inter-RAT measured results list"

– Inter-RAT measured result list

– CHOICE system

GSM

– Measured GSM cells

– GSM carrier RSSI

Check to see if present

CHOICE BSIC

Verified BSIC

– Inter-RAT cell id

Check that is set to "0"

– Observed time difference to GSM cell

Check that not present

R99 and Rel-4 only

– GSM carrier RSSI

Check to see if present

CHOICE BSIC

Verified BSIC

– Inter-RAT cell id

Check that is set to "1"

– Observed time difference to GSM cell

Check that not present

R99 and Rel-4 only

Event results

Check that not present

MEASUREMENT REPORT (Step 9)

Either:

Information Element

Value/remark

Version

Measurement identity

Check to see if set to 15

Measured Results

– CHOICE measurement

Check to see if set to "Inter-RAT measured results list"

– Inter-RAT measured result list

– CHOICE system

GSM

– Measured GSM cells

– GSM carrier RSSI

Not checked

CHOICE BSIC

Verified BSIC

– Inter-RAT cell id

Check that is set to "0" or “1”

– Observed time difference to GSM cell

Check that not present

R99 and Rel-4 only

– GSM carrier RSSI

Not checked

CHOICE BSIC

Verified BSIC

– Inter-RAT cell id

Check that is set to "1" or “0” (the cell id shall be different from the first reported cell id)

– Observed time difference to GSM cell

Check that not present

R99 and Rel-4 only

Measured results on RACH

Check that not present

Additional Measured results

Check that not present

Event results

Check that not present

Or:

Information Element

Value/remark

Version

Measurement identity

Check to see if set to 15

Measured Results

Check that not present

Measured results on RACH

Check that not present

Additional Measured results

Check that not present

Event results

Check that not present

MEASUREMENT REPORT (Step 9) (1.28 Mcps TDD)

Either:

Information Element

Value/remark

Version

Measurement identity

Check to see if set to 15

Measured Results

Check that not present

Measured results on RACH

Check that not present

Additional Measured results

Check that not present

Non Critical Extensions

– Additional Measured results – LCR

– CHOICE measurement

Check to see if set to "Inter-RAT measured results list"

– Inter-RAT measured result list

– CHOICE system

GSM

– Measured GSM cells

– GSM carrier RSSI

Not checked

CHOICE BSIC

Verified BSIC

– Inter-RAT cell id

Check that is set to "0" or “1”

– Observed time difference to GSM cell

Check that not present

R99 and Rel-4 only

– GSM carrier RSSI

Not checked

CHOICE BSIC

Verified BSIC

– Inter-RAT cell id

Check that is set to "1" or “0” (the cell id shall be different from the first reported cell id)

– Observed time difference to GSM cell

Check that not present

R99 and Rel-4 only

Event results

Check that not present

Or:

Information Element

Value/remark

Version

Measurement identity

Check to see if set to 15

Measured Results

Check that not present

Measured results on RACH

Check that not present

Additional Measured results

Check that not present

Event results

Check that not present

8.4.1.31.5 Test Requirement

In step 5 and step 6 UE reports correctly GSM RSSI values.

In step 8 UE reports correctly BSIC values.

In step 9 UE sends the next periodical report.

Reporting period is the requested one.

8.4.1.32 Void

8.4.1.33 Measurement Control and Report: Inter-RAT measurement, event 3a

8.4.1.33.1 Definition

8.4.1.33.2 Conformance requirement

1. When this event is ordered by UTRAN in a MEASUREMENT CONTROL message the UE shall send a report when the estimated quality of the currently used frequency is below the value of the IE "Threshold own system" and the hysteresis and time to trigger conditions are fulfilled and the estimated quality of the other system is above the value of the IE "Threshold other system" and the hysteresis and time to trigger conditions are fulfilled.

2. If the IE "DPCH Compressed Mode Status Info" is present, [in the MEASUREMENT CONTROL message]:

– after the time indicated by IE "TGPS reconfiguration CFN" has elapsed:

– activate the pattern sequence stored in the variable TGPS_IDENTITY corresponding to each IE "TGPSI" for which the "TGPS status flag" is set to "activate" at the time indicated by IE "TGCFN"; and

– begin the inter-frequency and/or inter-RAT measurements corresponding to the pattern sequence measurement purpose of each activated pattern sequence;

– if the values of IE "TGPS reconfiguration CFN" and IE "TGCFN" are equal:

– start the concerned pattern sequence immediately at that CFN;

– not alter pattern sequences stored in variable TGPS_IDENTITY, but not identified in IE "TGPSI"

Alternative 3 for R99 and Rel-4 only:

3. The UE shall perform GSM RSSI measurements in the gaps of compressed mode pattern sequence specified for GSM RSSI measurement purpose. The UE shall perform Initial BSIC identification in compressed mode pattern sequence specified for Initial BSIC identification measurement purpose. The UE shall be able to measure the "Observed time difference to GSM cell" during a compressed mode pattern sequence configured for this purpose. The UE shall perform BSIC re-confirmation in compressed mode pattern sequence specified for BSIC re-confirmation measurement purpose.

Alternative 3a for Rel-5 onwards:

3a. The UE shall perform GSM RSSI measurements in the gaps of compressed mode pattern sequence specified for GSM RSSI measurement purpose. The UE shall perform Initial BSIC identification in compressed mode pattern sequence specified for Initial BSIC identification measurement purpose. The UE shall perform BSIC re-confirmation in compressed mode pattern sequence specified for BSIC re-confirmation measurement purpose.

4. If the IE "Inter-RAT measurement quantity" is received in a MEASUREMENT CONTROL message and CHOICE system is GSM, the UE shall:

– if IE "BSIC verification required" is set to "required", for cells that match any of the BCCH ARFCN and BSIC combinations in the list of inter-RAT cells that the UE has received in IE "Inter-RAT cell info list", and that has a "verified" BSIC:

– report measurement quantities according to IE "inter-RAT reporting quantity" taking into account the restrictions defined in TS 25.331 clause 8.6.7.6;

– trigger inter-RAT events according to IE "inter-RAT measurement reporting criteria"; and

– perform event evaluation for event-triggered reporting after BSIC has been verified for a GSM cell

– indicate non-verified BSIC for a GSM cell in the "Inter-RAT measured results list" IE

5. The UE shall include measured results in MEASUREMENT REPORT as specified in the IE "Inter-RAT reporting quantity".

Alternative 6 for R99 and Rel-4 only:

6. If IE "Observed time difference to GSM cell Reporting indicator " is set to "TRUE" [, the UE shall]:

include optional IE "Observed time difference to GSM cell" with the value set to the time difference to that GSM cell for the GSM cells that have a BSIC that is "verified", and that match any of the BCCH ARFCN and BSIC combinations in the list of inter-RAT cells that the UE has received in IE "Inter-RAT cell info list".

– if IE "GSM Carrier RSSI" is set to "TRUE"[, the UE shall]:

– include optional IE "GSM Carrier RSSI" with a value set to the measured RXLEV to that GSM cell in IE "Inter-RAT measured results list".

– if the BSIC of reported GSM cell is "verified"[, the UE shall]:

– set the CHOICE BSIC to "Verified BSIC" and IE "inter-RAT cell id" to the value that GSM cell had in the IE "Inter-RAT cell info list";

Alternative 6a for Rel-5 onwards:

6a. If

– IE "GSM Carrier RSSI" is set to "TRUE"[, the UE shall]:

– include optional IE "GSM Carrier RSSI" with a value set to the measured RXLEV to that GSM cell in IE "Inter-RAT measured results list".

– if the BSIC of reported GSM cell is "verified"[, the UE shall]:

– set the CHOICE BSIC to "Verified BSIC" and IE "inter-RAT cell id" to the value that GSM cell had in the IE "Inter-RAT cell info list";

7. If the IE "Reporting Cell Status" is received, the UE shall set the IE "Measured Results" in MEASUREMENT REPORT as follows.

– the maximum number of the IE "Cell Measured Results" to be included in the IE "Measured Results" is the number specified in "Reporting Cell Status".

Reference

3GPP TS 25.331 clauses 8.4.1.3, 8.6.7.5, 8.6.7.6, 8.6.7.9, 14.3.1.1, 14.3.2.1, 14.3.2.2, 14.3.2.3.

8.4.1.33.3 Test Purpose

1. To confirm that the UE starts compressed mode and inter-RAT measurements when so required by the network in a MEASUREMENT CONTROL message.

2. To confirm that the UE sends MEASUREMENT REPORT message if event 3a is configured, if the quality of the currently used UTRAN frequency is below a given threshold and the estimated quality of the other system is above a certain threshold.

3. To confirm that the hysteresis and time to trigger behaviours for event 3a are correctly implemented.

4. To confirm that the UE verifies the BSIC of the cell triggering the event if so required by UTRAN and if the proper compressed mode patterns have been configured in the UE by UTRAN.

5. To confirm that the content of the MEASUREMENT REPORT sent by the UE is according to what was required by UTRAN.

NOTE: Test purpose 1 verifies conformance requirement 1 and 2.

NOTE: Test purpose 2 and 3 verifies conformance requirement 1.

NOTE: Test purpose 4 verifies conformance requirement 2, 3 and 4.

NOTE: Test purpose 5 verifies conformance requirement 4, 5, 6 and 7.

8.4.1.33.4 Method of test

Initial Condition

System simulator: 1 UTRAN FDD cell (or TDD cell) and 3 GSM cells. The initial configurations of the 3 cells in the SS shall follow the values indicated in the column marked T0. The table is found in "Test procedure". The UTRAN FDD cell shall use UARFCN according to the band under test except in the case of where FDD band VIII is tested and GSM900 is used for the Inter-RAT cells, then “High Range” test frequency for Band VIII is used instead, to avoid the test channels overlapping.

UE: CS-DCCH+DTCH_DCH (State 6-9) or PS-DCCH+DTCH_DCH (State 6-10) in cell 1 (UTRA) as specified in clause 7.4 of TS 34.108, depending on the CN domain supported by the UE.

Related ICS/IXIT statements

– Compressed mode required yes/no

– UE supports GSM-P, GSM-E, GSM-DCS, GSM-450, GSM-480, GSM-PCS, GSM-850.

Test procedure

Table 8.4.1.33.4-1

Parameter

Unit

Cell 1 (GSM)

Cell 2 (GSM)

Cell 3 (GSM)

T0

T1

T2

T3

T4

T0

T1

T2

T3

T4

T0

T1

T2

T3

T4

Test Channel

#

GSM Ch.1

GSM Ch.2

GSM Ch.3

BCCH ARFCN

#

Value according to the GSM band under test (see 3GPP 34.123-1 table 6.5 for details on the ARFCN)

Value according to the GSM band under test (see 3GPP 34.123-1 table 6.5 for details on the ARFCN)

Value according to the GSM band under test (see 3GPP 34.123-1 table 6.5 for details on the ARFCN)

CELL identity

#

0

1

2

BSIC

#

BSIC 1

BSIC 2

BSIC 3

RF Signal Level

dBm

-85

-85

-70

-76

-70

-85

-85

-85

-84

-84

-90

-90

-90

-90

-90

Table 8.4.1.33.4-2

Parameter

Unit

Cell 1 (UTRA)

T0

T1

T2

T3

T4

UTRA RF Channel Number

Mid Range Test Frequency

CPICH Ec (FDD)

dBm/3.84Mhz

-60

-80

-80

-80

-60

P-CCPCH (TDD)

dBm

-60

-80

-80

-80

-60

The two tables above illustrate the downlink power to be applied for the two cells at various instants of the test execution. Column marked "T0" denotes the initial conditions, while columns marked "T1", "T2", "T3" and "T4" indicate the values to be applied subsequently.

The UE is initially in CELL_DCH state as specified in clause 7.4 of TS 34.108. UTRA cell 1 is the only cell in the active set of the UE. If the UE requires compressed mode (refer ICS/IXIT), the SS sends a PHYSICAL CHANNEL RECONFIGURATION message to the UE to configure the compressed mode pattern sequence parameters to the UE. Three compressed mode patterns are configured, according to the message specified below. When the PHYSICAL CHANNEL RECONFIGURATION COMPLETE is received from the UE, the SS sends a MEASUREMENT CONTROL message to the UE, to set up inter-RAT measurements. Event 3a is set up in this message, and if the UE requires compressed mode (refer ICS/IXIT), compressed mode is activated.

At instant T1, the CPICH Ec drops as described in table 8.4.1.33.4-2.

At instant T2, the RF signal for GSM cell 1 increases, and crosses the threshold for the other system defined for event 3a.

After reception of the MEASUREMENT REPORT message, at instant T3, the RF signal strength for GSM cell 2 increases but remains below the threshold for the other system for event 3a. During that time, the RF signal strength for GSM cell 1 decreases, but remains above the releasing condition for event 3a.

At instant T4, the RF signal strength for GSM cell 1 increases above the threshold for the other system for event 3a+hysteresis. SS calls for generic procedure C.3 to check that UE is in CELL_DCH state.

Expected Sequence

Step

Direction

Message

Comment

UE

SS

1

The UE is brought to the CELL_DCH state in the cell 1.

If the UE does not require compressed mode (refer ICS/IXIT), then goto step 4.

2

PHYSICAL CHANNEL RECONFIGURATION

Compressed mode pattern sequence parameters are loaded to UE.

3

PHYSICAL CHANNEL RECONFIGURATION COMPLETE

4

MEASUREMENT CONTROL

SS configures event 3a in the UE. If the UE requires compressed mode (refer ICS/IXIT), compressed mode is started.

5

SS re-adjusts the downlink transmission power settings according to columns "T1" in tables 8.4.1.33.4-1 and 8.4.1.33.4-2.

6

SS waits for approximately 10 seconds and verifies that no MEASUREMENT REPORT messages are detected on uplink DCCH.

7

SS re-adjusts the downlink transmission power settings according to columns "T2" in tables 8.4.1.33.4-1 and 8.4.1.33.4-2.

8

MEASUREMENT REPORT

After about 2s, the UE sends a MEASUREMENT REPORT to SS triggered by event 3a.

9

SS re-adjusts the downlink transmission power settings according to columns "T3" in tables 8.4.1.33.4-1 and 8.4.1.33.4-2.

10

SS waits for approximately 10 seconds and verifies that no MEASUREMENT REPORT messages are detected on uplink DCCH.

11

SS re-adjusts the downlink transmission power settings according to columns "T4" in tables 8.4.1.33.4-1 and 8.4.1.33.4-2.

12

SS waits for approximately 10 seconds and verifies that no MEASUREMENT REPORT messages are detected on uplink DCCH.

13



CALL C.3

If the test result of C.3 indicates that UE is in CELL_DCH state, the test passes, otherwise it fails.

Specific Message Content

PHYSICAL CHANNEL RECONFIGURATION (Step 2)

Use the same message sub-type in clause 9 of TS 34.108 titled "Non speech in CS" or "Speech in CS" or "Packet to CELL_DCH from CELL_DCH in PS, with Scrambling code change set to Default1 and with the following exceptions:

Information Element

Value/remark

Version

Downlink information common for all radio links

– DPCH compressed mode info

– TGPSI

1

– TGPS Status Flag

Deactivate

– TGCFN

Not present

– Transmission gap pattern sequence configuration parameters

– TGMP

GSM Carrier RSSI Measurement

– TGPRC

Infinity

– TGSN

4

– TGL1

7

– TGL2

Not present

– TGD

undefined

– TGPL1

12

– TGPL2

Not present

R99 and REL-4 only

– RPP

Mode 1

– ITP

Mode 0

CHOICE UL/DL Mode

UL&DL or UL-only or DL-only (depends on UE’s Measurement capability)

– Downlink compressed mode method

SF/2

– Uplink compressed mode method

SF/2

– Downlink frame type

A

– DeltaSIR1

10 (1.0)

– DeltaSIRAfter1

5 (0.5)

– DeltaSIR2

Not Present

– DeltaSIR2After2

Not Present

– N identify abort

Not Present

– T Reconfirm abort

Not Present

– TGPSI

2

– TGPS Status Flag

Deactivate

– TGCFN

Not present

– Transmission gap pattern sequence configuration parameters

– TGMP

GSM BSIC identification

– TGPRC

Infinity

– TGSN

4

– TGL1

7

– TGL2

Not present

– TGD

undefined

– TGPL1

8

– TGPL2

Not present

R99 and REL-4 only

– RPP

Mode 1

– ITP

Mode 0

CHOICE UL/DL Mode

UL&DL or UL-only or DL-only (depends on UE’s Measurement capability)

– Downlink compressed mode method

SF/2

– Uplink compressed mode method

SF/2

– Downlink frame type

A

– DeltaSIR1

10 (1.0)

– DeltaSIRAfter1

5 (0.5)

– DeltaSIR2

Not Present

– DeltaSIR2After2

Not Present

– N identify abort

66

– T Reconfirm abort

Not Present

– TGPSI

3

– TGPS Status Flag

Deactivate

– TGCFN

Not present

– Transmission gap pattern sequence configuration parameters

– TGMP

GSM BSIC re-confirmation

– TGPRC

Infinity

– TGSN

4

– TGL1

7

– TGL2

Not present

– TGD

undefined

– TGPL1

8

– TGPL2

Not present

R99 and REL-4 only

– RPP

Mode 1

– ITP

Mode 0

CHOICE UL/DL Mode

UL&DL or UL-only or DL-only (depends on UE’s Measurement capability)

– Downlink compressed mode method

SF/2

– Uplink compressed mode method

SF/2

– Downlink frame type

A

– DeltaSIR1

10 (1.0)

– DeltaSIRAfter1

5 (0.5)

– DeltaSIR2

Not Present

– DeltaSIR2After2

Not Present

– N identify abort

Not Present

– T Reconfirm abort

10 (5 s)

Downlink information per radio link list

– Choice mode

FDD

– Primary CPICH info

– Primary scrambling code

Ref. to the Default setting in clause 6.1 (FDD)

– PDSCH with SHO DCH info

Not Present

R99 and Rel-4 only

– PDSCH code mapping

Not Present

R99 and Rel-4 only

– Serving HS-DSCH radio link indicator

FALSE

Rel-5

– Serving E-DCH radio link indicator

FALSE

Rel-6

– Downlink DPCH info for each RL

– CHOICE mode

FDD

– Primary CPICH usage for channel estimation

Primary CPICH may be used

– DPCH frame offset

Set to value : Default DPCH Offset Value (as currently stored in SS) mod 38 400

– Secondary CPICH info

Not Present

– DL channelisation code

– Secondary scrambling code

5

– Spreading factor

Reference to clause 6.10 Parameter Set

– Code number

0

– Scrambling code change

Set to value Default1: No code change (if the UE has a compressed mode pattern sequence configured in variable TGPS_IDENTITY or included in the message including IE "Downlink DPCH info for each RL", which is using compressed mode method "SF/2")

– TPC combination index

0

– SSDT Cell Identity

Not Present

R99 and Rel-4 only

– Closed loop timing adjustment mode

Not Present

– E-AGCH Info

Not Present

Rel-6

– E-HICH Information

Not Present

Rel-6

– E-RGCH Information

Not Present

Rel-6

– SCCPCH information for FACH

Not Present

R99 and Rel-4 only

MEASUREMENT CONTROL (Step 4) (FDD)

Information Element

Value/remark

Measurement Identity

3

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Event triggered

Additional measurements list

Not Present

CHOICE measurement type

– inter-RAT measurement

– inter-RAT measurement object list

CHOICE Inter-RAT Cell Removal

Remove all inter-RAT cells

-Remove all inter-RAT cells

(No Data)

New inter-RAT cells (1 to <MaxCellMeas>)

– inter-RAT cell id

0

CHOICE Radio Access Technology

GSM

– Cell individual offset

0

– Cell selection and re-selection info

Not present

– BSIC

BSIC1

– Band indicator

GSM/DCS-1800 or GSM/PCS-1900 (dependent on band used)

– BCCH ARFCN

Value according to the GSM band under test (see 3GPP 34.123-1 table 6.5 for details on the ARFCN)

– inter-RAT cell id

1

CHOICE Radio Access Technology

GSM

– Cell individual offset

0

– Cell selection and re-selection info

Not present

– BSIC

BSIC2

– Band indicator

GSM/DCS-1800 or GSM/PCS-1900 (dependent on band used)

– BCCH ARFCN

Value according to the GSM band under test (see 3GPP 34.123-1 table 6.5 for details on the ARFCN)

– inter-RAT cell id

2

CHOICE Radio Access Technology

GSM

– Cell individual offset

0

– Cell selection and re-selection info

Not present

– BSIC

BSIC3

– Band indicator

DCS 1800 band used

– BCCH ARFCN

39

– Cell for measurement

Not present

– inter-RAT measurement quantity

– Measurement quantity for UTRAN quality estimate

– Intra-frequency measurement quantity

– Filter coefficient

0

– CHOICE mode

FDD

– Measurement quantity

CPICH RSCP

CHOICE system

GSM

– Measurement quantity

GSM carrier RSSI

– Filter coefficient

0

– BSIC verification required

required

– inter-RAT reporting quantity

CHOICE system

GSM

– Observed time difference to GSM cell reporting indicator

FALSE

– GSM carrier RSSI reporting indicator

TRUE

CHOICE report criteria

– Inter-RAT measurements reporting criteria

– Parameters required for each event

(1 to<maxMeasEvent>)

– Inter-RAT event identity

3a

– Threshold own system

-66

– W

0

– Threshold other system

-80

– Hysteresis

5 (2.5 dB)

– Time to Trigger

640 ms

– Reporting cell status

Report cells within active set or within virtual active set or of the other RAT

– Maximum number of reported cells

2 cells

Physical channel information elements

– DPCH compressed mode status info

If the UE requires compressed mode (refer ICS/IXIT), this IE is present and contains the IEs as follows. If the UE does not require compressed mode (refer ICS/IXIT), this IE is not present.

– TGPS reconfiguration CFN

(Current CFN + (250 – TTI/10msec))mod 256

– Transmission gap pattern sequence (1 to <MaxTGPS>)

– TGPSI

1

– TGPS status flag

Activate

– TGCFN

(Current CFN + (252 – TTI/10msec))mod 256

– TGPSI

2

– TGPS status flag

Activate

– TGCFN

(Current CFN + (254 – TTI/10msec))mod 256

– TGPSI

3

– TGPS status flag

Activate

– TGCFN

(Current CFN + (250 – TTI/10msec))mod 256

MEASUREMENT CONTROL (Step 4) (TDD)

Information Element

Value/remark

Measurement Identity

3

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Event triggered

Additional measurements list

Not Present

CHOICE measurement type

– inter-RAT measurement

– inter-RAT measurement object list

CHOICE Inter-RAT Cell Removal

Remove all inter-RAT cells

-Remove all inter-RAT cells

(No Data)

New inter-RAT cells (1 to <MaxCellMeas>)

– inter-RAT cell id

0

CHOICE Radio Access Technology

GSM

– Cell individual offset

0

– Cell selection and re-selection info

Not present

– BSIC

BSIC1

– Band indicator

DCS 1800 band used

– BCCH ARFCN

1

– inter-RAT cell id

1

CHOICE Radio Access Technology

GSM

– Cell individual offset

0

– Cell selection and re-selection info

Not present

– BSIC

BSIC2

– Band indicator

DCS 1800 band used

– BCCH ARFCN

7

– inter-RAT cell id

2

CHOICE Radio Access Technology

GSM

– Cell individual offset

0

– Cell selection and re-selection info

Not present

– BSIC

BSIC3

– Band indicator

DCS 1800 band used

– BCCH ARFCN

39

– Cell for measurement

Not present

– inter-RAT measurement quantity

– Measurement quantity for UTRAN quality estimate

– Intra-frequency measurement quantity

– Filter coefficient

0

– CHOICE mode

TDD

– Measurement quantity

CCPCH RSCP

CHOICE system

GSM

– Measurement quantity

GSM carrier RSSI

– Filter coefficient

0

– BSIC verification required

required

– inter-RAT reporting quantity

CHOICE system

GSM

– Observed time difference to GSM cell reporting indicator

FALSE

– GSM carrier RSSI reporting indicator

TRUE

CHOICE report criteria

– Inter-RAT measurements reporting criteria

– Parameters required for each event

(1 to<maxMeasEvent>)

– Inter-RAT event identity

3a

– Threshold own system

-66

– W

0

– Threshold other system

-80

– Hysteresis

5 (2.5 dB)

– Time to Trigger

640 ms

– Reporting cell status

Report cells within active set or within virtual active set or of the other RAT

– Maximum number of reported cells

2 cells

Physical channel information elements

MEASUREMENT REPORT (Step 8)

Information Element

Value/remark

Version

Measurement identity

Check to see if set to 3

Measured Results

– CHOICE measurement

Check to see if set to "Inter-RAT measured results list"

– Inter-RAT measured result list

– CHOICE system

GSM

– Measured GSM cells

Check that measurement results for two GSM cells are included

– GSM carrier RSSI

Check that measurement result is reasonable. RXLEV is mapped to a value between 0 and 63. The RSSI bits are numbered b0 to b5, where b0 is the least significant bit. When mapping the RXLEV value to the RSSI bit string, the first/ leftmost bit of the bit string contains the most significant bit.

CHOICE BSIC

Check it is set to verified BSIC

– inter-RAT cell id

Check that it is set to 0.

– Observed time difference to GSM cell

Check that not present

R99 and Rel-4 only

– GSM carrier RSSI

Check that measurement result is reasonable

CHOICE BSIC

Verified BSIC

– inter-RAT cell id

Check that is set to 1

– Observed time difference to GSM cell

Check that not present

R99 and Rel-4 only

Measured results on RACH

Check that not present

Additional Measured results

Check that not present

Event results

Check that the IE is included

– CHOICE event result

Check that this is set to inter-RAT measurement event results

– Inter-RAT event identity

Check that this is set to 3a

– Cells to report (1 to <maxCellMeas>)

Check that <maxCellMeas> is set to 1

– CHOICE BSIC

Check that this is set to verified BSIC

– Inter-RAT cell id

Check that this is set to 0.

MEASUREMENT REPORT (Step 8) (1.28 Mcps TDD)

Information Element

Value/remark

Version

Measurement identity

Check to see if set to 3

Measured Results

Check that not present

Measured results on RACH

Check that not present

Additional Measured results

Check that not present

Non Critical Extensions

– Additional Measured results – LCR

– CHOICE measurement

Check to see if set to "Inter-RAT measured results list"

– Inter-RAT measured result list

– CHOICE system

GSM

– Measured GSM cells

Check that measurement results for two GSM cells are included

– GSM carrier RSSI

Check that measurement result is reasonable. RXLEV is mapped to a value between 0 and 63. The RSSI bits are numbered b0 to b5, where b0 is the least significant bit. When mapping the RXLEV value to the RSSI bit string, the first/ leftmost bit of the bit string contains the most significant bit.

CHOICE BSIC

Check it is set to verified BSIC

– inter-RAT cell id

Check that it is set to 0.

– Observed time difference to GSM cell

Check that not present

R99 and Rel-4 only

– GSM carrier RSSI

Check that measurement result is reasonable

CHOICE BSIC

Verified BSIC

– inter-RAT cell id

Check that is set to 1

– Observed time difference to GSM cell

Check that not present

R99 and Rel-4 only

Event results

Check that the IE is included

– CHOICE event result

Check that this is set to inter-RAT measurement event results

– Inter-RAT event identity

Check that this is set to 3a

– Cells to report (1 to <maxCellMeas>)

Check that <maxCellMeas> is set to 1

– CHOICE BSIC

Check that this is set to verified BSIC

– Inter-RAT cell id

Check that this is set to 0.

8.4.1.33.5 Test requirement

The UE shall not send any measurement report between instants T1 and T2.

Event 3a shall be triggered in the UE (i.e. the transmission of the MEASUREMENT REPORT) after instant T2.

Between instants T2 and T3, no MEASUREMENT REPORT message shall be received from the UE (since the hysteresis condition for triggering event 3a is not fulfilled).

No MEASUREMENT REPORT message shall be received from the UE after instant T4 (since the signal strength for cell 1 has not dropped under Threshold for event 3a-hysteresis).

8.4.1.34 Measurement Control and Report: Inter-RAT measurement, event 3b

8.4.1.34.1 Definition

8.4.1.34.2 Conformance requirement

If the IE "Inter-RAT cell info list" is received in a MEASUREMENT CONTROL message, the UE shall update the variable CELL_INFO_LIST accordingly and in the following order. The UE shall:

– if the IE "Removed Inter-RAT cells" is received, at the position indicated by the IE "Inter-RAT cell id":

– clear the cell information stored in the variable CELL_INFO_LIST; and

– mark the position "vacant";

– if the IE "New Inter-RAT cells" is received, for each cell, and in the same order as the cells appear in the IE:

– update the variable CELL_INFO_LIST as follows:

– if the IE "Inter-RAT cell id" is received:

– store received cell information at this position in the Inter-RAT cell info list in the variable CELL_INFO_LIST, possibly overwriting any existing information in this position; and

– mark the position "occupied";

– if the IE "Inter-RAT cell id" is not received:

– store the received cell information at the first vacant position in ascending order in the Inter-RAT cell info list in the variable CELL_INFO_LIST; and

– mark the position as "occupied";

When event 3b is configured in the UE within a measurement, the UE shall:

1> if the other RAT is GSM, and if IE "BSIC verification required" is set to "required":

2> if equation 1 below has been fulfilled for a time period indicated by "time to trigger" for one or several GSM cells that match any of the BCCH ARFCN and BSIC combinations considered in that inter-RAT measurement:

3> if the inter-RAT cell id of any of those GSM cell is not stored in the variable TRIGGERED_3B_EVENT:

4> store the inter-RAT cell ids of the GSM cells that triggered the event and that were not previously stored in the variable TRIGGERED_3B_EVENT into that variable;

4> send a measurement report with IEs set as below:

5> set in "inter-RAT measurement event result": "inter-RAT event identity" to "3b", "CHOICE BSIC" to "verified BSIC" and "Inter-RAT cell id" to the GSM cells that triggered the event (worst one first);

5> set the IE "measured results" and the IE "additional measured results" according to TS 25.331 subclause 8.4.2 , not taking into account the cell individual offset;

2> if equation 2 below is fulfilled for a GSM cell whose inter-RAT cell id is stored in the variable TRIGGERED_3B_EVENT:

3> remove the inter-RAT cell id of that GSM cell from the variable TRIGGERED_3B_EVENT.

1> if the other RAT is GSM, and if IE "BSIC verification required" is set to "not required":

2> if equation 1 below has been fulfilled for a time period indicated by "time to trigger" for one or several of the BCCH ARFCNs considered in that inter-RAT measurement:

3> if any of those BCCH ARFCN is not stored into the variable TRIGGERED_3B_EVENT:

4> store the BCCH ARFCNs that triggered the event and that were not previously stored in the variable TRIGGERED_3B_EVENT into that variable;

4> send a measurement report with IEs set as below:

5> set in "inter-RAT measurement event result": "inter-RAT event identity" to "3b", "CHOICE BSIC" to "non verified BSIC" and "BCCH ARFCN" to BCCH ARFCNs that triggered the event (worst one first);

5> set the IE "measured results" and the IE "additional measured results" according to 8.4.2, not taking into account the cell individual offset;

2> if equation 2 below is fulfilled for a BCCH ARFCN that is stored in the variable TRIGGERED_3B_EVENT:

3> remove that BCCH ARFCN from the variable TRIGGERED_3B_EVENT.

Triggering condition:

Equation 1:

The variables in the formula are defined as follows:

MOther RAT is the measurement quantity for the cell of the other system.

CIOOther RAT is the cell individual offset for the cell of the other system.

TOther RAT is the absolute threshold that applies for the other system in that measurement.

H3b is the hysteresis parameter for event 3b.

Leaving triggered state condition:

Equation 2:

The variables in the formula are defined as follows:

MOther RAT is the measurement quantity for the cell of the other system. MOther RAT is expressed in dBm.

CIOOther RAT is the cell individual offset for the cell of the other system.

TOther RAT is the absolute threshold that applies for the other system in that measurement.

H3b is the hysteresis parameter for event 3b.

Reference

3GPP TS 25.331 clause 8.6.7.3, 14.3.1.2

8.4.1.34.3 Test Purpose

1 To confirm that the UE sends MEASUREMENT REPORT message if event 3b is configured, if the estimated quality of the other system is below a given threshold.

2 To confirm that the hysteresis and time to trigger behaviours for event 3b are correctly implemented. To confirm that the UE updates the list of inter-RAT cells it stores according to what is ordered in the MEASUREMENT CONTROL messages received from UTRAN.

8.4.1.34.4 Method of test

Initial Condition

System simulator: 1 UTRAN FDD cell (or TDD cell) and 3 GSM cells. The initial configurations of the 3 GSM cells in the SS shall follow the values indicated in the column marked T0. The table is found in "Test procedure". The UTRAN FDD cell shall use UARFCN according to the band under test except in the case of where FDD band VIII is tested and GSM900 is used for the Inter-RAT cells, then “High Range” test frequency for Band VIII is used instead, to avoid the test channels overlapping.

UE: CS-DCCH+DTCH_DCH (State 6-9) or PS-DCCH+DTCH_DCH (State 6-10) in cell 1 (UTRA) as specified in clause 7.4 of TS 34.108, depending on the CN domain supported by the UE.

Related ICS/IXIT statements

– Compressed mode required yes/no

– UE supports GSM-P, GSM-E, GSM-DCS, GSM-450, GSM-480, GSM-PCS, GSM-850.

Test procedure

Table 8.4.1.34.4-1

Parameter

Unit

Cell 1 (GSM)

Cell 2 (GSM)

Cell 3 (GSM)

T0

T1

T0

T1

T0

T1

Test Channel

#

GSM Ch.1

GSM Ch.2

GSM Ch.3

BCCH ARFCN

#

Value according to the GSM band under test (see 3GPP 34.123-1 table 6.5 for details on the ARFCN)

Value according to the GSM band under test (see 3GPP 34.123-1 table 6.5 for details on the ARFCN)

Value according to the GSM band under test (see 3GPP 34.123-1 table 6.5 for details on the ARFCN)

CELL identity

#

0

1

2

BSIC

#

BSIC 1

BSIC 2

BSIC 3

RF Signal Level

dBm

-70

-90

-70

-70

-90

-90

The table above illustrate the downlink power to be applied for the cells at various instants of the test execution. Column marked "T0" denotes the initial conditions, while column marked "T1" indicates the values to be applied subsequently.

The UE is initially in CELL_DCH state as specified in clause 7.4 of TS 34.108. UTRA cell 1 is the only cell in the active set of the UE. If the UE requires compressed mode (refer ICS/IXIT), the SS sends a PHYSICAL CHANNEL RECONFIGURATION message to the UE to configure the compressed mode pattern sequence parameters to the UE. Three compressed mode patterns are configured, according to the message specified below. When the PHYSICAL CHANNEL RECONFIGURATION COMPLETE is received from the UE, the SS sends a MEASUREMENT CONTROL message to the UE, to set up inter-RAT measurements. Event 3b is set up in this message, and if the UE requires compressed mode (refer ICS/IXIT), compressed mode is activated. The monitored GSM cells at measurement establishment are GSM cells 1 and 2.

At instant T1, the RF signal strength for GSM cell 1 drops as described in table 8.4.1.34.4-1.

When the MEASUREMENT REPORT has been received by the SS, a MEASUREMENT CONTROL message is sent to the UE, to add GSM cell 3 to the monitored GSM cells.

A second MEASUREMENT REPORT triggered by event 3b shall be received shortly after by the SS. SS calls for generic procedure C.3 to check that UE is in CELL_DCH state.

Expected Sequence

Step

Direction

Message

Comment

UE

SS

1

The UE is brought to the CELL_DCH state in the cell 1.

If the UE does not require compressed mode (refer ICS/IXIT), then goto step 4.

2

PHYSICAL CHANNEL RECONFIGURATION

Compressed mode pattern sequence parameters are loaded to UE.

3

PHYSICAL CHANNEL RECONFIGURATION COMPLETE

4

MEASUREMENT CONTROL

SS configures event 3b in the UE. If the UE requires compressed mode (refer ICS/IXIT), compressed mode is started.

5

SS waits for approximately 10 seconds and verifies that no MEASUREMENT REPORT messages are detected on uplink DCCH.

6

SS re-adjusts the downlink transmission power settings according to columns "T1" in tables 8.4.1.34.4-1.

7

MEASUREMENT REPORT

After about 1020m s, the UE sends a MEASUREMENT REPORT to SS triggered by event 3b.

8

MEASUREMENT CONTROL

SS adds GSM cell 3 to the list of the monitored GSM cells.

9

MEASUREMENT REPORT

After about 5.8 s, the UE sends a MEASUREMENT REPORT to SS triggered by event 3b.

10



CALL C.3

If the test result of C.3 indicates that UE is in CELL_DCH state, the test passes, otherwise it fails.

Specific Message Content

PHYSICAL CHANNEL RECONFIGURATION (Step 2)

Use the same message sub-type in clause 9 of TS 34.108 titled "Non speech in CS" or "Speech in CS" or "Packet to CELL_DCH from CELL_DCH in PS, with Scrambling code change set to Default1 and with the following exceptions:

Information Element

Value/remark

Version

Downlink information common for all radio links

– DPCH compressed mode info

– TGPSI

1

– TGPS Status Flag

Deactivate

– TGCFN

Not present

– Transmission gap pattern sequence configuration parameters

– TGMP

GSM Carrier RSSI Measurement

– TGPRC

Infinity

– TGSN

4

– TGL1

7

– TGL2

Not present

– TGD

undefined

– TGPL1

12

– TGPL2

Not present

R99 and REL-4 only

– RPP

Mode 0

– ITP

Mode 0

CHOICE UL/DL Mode

UL&DL or UL-only or DL-only (depends on UE’s Measurement capability)

– Downlink compressed mode method

SF/2

– Uplink compressed mode method

SF/2

– Downlink frame type

A

– DeltaSIR1

10 (1.0)

– DeltaSIRAfter1

5 (0.5)

– DeltaSIR2

Not Present

– DeltaSIR2After2

Not Present

– N identify abort

Not Present

– T Reconfirm abort

Not Present

– TGPSI

2

– TGPS Status Flag

Deactivate

– TGCFN

Not present

– Transmission gap pattern sequence configuration parameters

– TGMP

GSM BSIC identification

– TGPRC

Infinity

– TGSN

4

– TGL1

7

– TGL2

Not present

– TGD

undefined

– TGPL1

8

– TGPL2

Not present

R99 and REL-4 only

– RPP

Mode 0

– ITP

Mode 0

CHOICE UL/DL Mode

UL&DL or UL-only or DL-only (depends on UE’s Measurement capability)

– Downlink compressed mode method

SF/2

– Uplink compressed mode method

SF/2

– Downlink frame type

A

– DeltaSIR1

10 (1.0)

– DeltaSIRAfter1

5 (0.5)

– DeltaSIR2

Not Present

– DeltaSIR2After2

Not Present

– N identify abort

66

– T Reconfirm abort

Not Present

– TGPSI

3

– TGPS Status Flag

Deactivate

– TGCFN

Not present

– Transmission gap pattern sequence configuration parameters

– TGMP

GSM BSIC re-confirmation

– TGPRC

Infinity

– TGSN

4

– TGL1

7

– TGL2

Not present

– TGD

undefined

– TGPL1

8

– TGPL2

Not present

R99 and REL-4 only

– RPP

Mode 0

– ITP

Mode 0

CHOICE UL/DL Mode

UL&DL or UL-only or DL-only (depends on UE’s Measurement capability)

– Downlink compressed mode method

SF/2

– Uplink compressed mode method

SF/2

– Downlink frame type

A

– DeltaSIR1

10 (1.0)

– DeltaSIRAfter1

5 (0.5)

– DeltaSIR2

Not Present

– DeltaSIR2After2

Not Present

– N identify abort

Not Present

– T Reconfirm abort

10 (5 s)

Downlink information per radio link list

– Choice mode

FDD

– Primary CPICH info

– Primary scrambling code

Ref. to the Default setting in clause 6.1 (FDD)

– PDSCH with SHO DCH info

Not Present

R99 and Rel-4 only

– PDSCH code mapping

Not Present

R99 and Rel-4 only

– Serving HS-DSCH radio link indicator

FALSE

Rel-5

– Serving E-DCH radio link indicator

FALSE

Rel-6

– Downlink DPCH info for each RL

– CHOICE mode

FDD

– Primary CPICH usage for channel estimation

Primary CPICH may be used

– DPCH frame offset

Set to value : Default DPCH Offset Value (as currently stored in SS) mod 38 400

– Secondary CPICH info

Not Present

– DL channelisation code

– Secondary scrambling code

5

– Spreading factor

Reference to clause 6.10 Parameter Set

– Code number

0

– Scrambling code change

Set to value Default1: No code change (if the UE has a compressed mode pattern sequence configured in variable TGPS_IDENTITY or included in the message including IE "Downlink DPCH info for each RL", which is using compressed mode method "SF/2")

– TPC combination index

0

– SSDT Cell Identity

Not Present

R99 and Rel-4 only

– Closed loop timing adjustment mode

Not Present

– E-AGCH Info

Not Present

Rel-6

– E-HICH Information

Not Present

Rel-6

– E-RGCH Information

Not Present

Rel-6

– SCCPCH information for FACH

Not Present

R99 and Rel-4 only

MEASUREMENT CONTROL (Step 4)(FDD)

Information Element

Value/remark

Measurement Identity

3

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Event triggered

Additional measurements list

Not Present

CHOICE measurement type

– inter-RAT measurement

– inter-RAT measurement object list

CHOICE Inter-RAT Cell Removal

Remove all inter-RAT cells

-Remove all inter-RAT cells

(No Data)

New inter-RAT cells (1 to <MaxCellMeas>)

– inter-RAT cell id

0

CHOICE Radio Access Technology

GSM

– Cell individual offset

0

– Cell selection and re-selection info

Not present

– BSIC

BSIC1

– Band indicator

GSM/DCS-1800 or GSM/PCS-1900 (dependent on band used)

– BCCH ARFCN

Value according to the GSM band under test (see 3GPP 34.123-1 table 6.5 for details on the ARFCN)

– inter-RAT cell id

1

CHOICE Radio Access Technology

GSM

– Cell individual offset

0

– Cell selection and re-selection info

Not present

– BSIC

BSIC2

– Band indicator

GSM/DCS-1800 or GSM/PCS-1900 (dependent on band used)

– BCCH ARFCN

Value according to the GSM band under test (see 3GPP 34.123-1 table 6.5 for details on the ARFCN)

– Cell for measurement

Not present

– inter-RAT measurement quantity

– Measurement quantity for UTRAN quality estimate

Not included

CHOICE system

GSM

– Measurement quantity

GSM carrier RSSI

– Filter coefficient

0

– BSIC verification required

required

– inter-RAT reporting quantity

CHOICE system

GSM

– Observed time difference to GSM

FALSE

cell reporting indicator

– GSM carrier RSSI reporting indicator

TRUE

CHOICE report criteria

– Inter-RAT measurements reporting criteria

– Parameters required for each event

(1 to<maxMeasEvent>)

– Inter-RAT event identity

3b

– Threshold own system

Not included

– W

Not included

– Threshold other system

-80

– Hysteresis

2 (1 dB)

– Time to Trigger

60 ms

– Reporting cell status

Report cells within active set or within virtual active set or of the other RAT

– Maximum number of reported cells

3

Physical channel information elements

– DPCH compressed mode status info

If the UE requires compressed mode (refer ICS/IXIT), this IE is present and contains the IEs as follows. If the UE does not require compressed mode (refer ICS/IXIT), this IE is not present.

– TGPS reconfiguration CFN

(Current CFN + (250 – TTI/10msec))mod 256

– Transmission gap pattern sequence (1 to <MaxTGPS>)

– TGPSI

1

– TGPS status flag

Activate

– TGCFN

(Current CFN + (252 – TTI/10msec))mod 256

– TGPSI

2

– TGPS status flag

Activate

– TGCFN

(Current CFN + (254 – TTI/10msec))mod 256

– TGPSI

3

– TGPS status flag

Activate

– TGCFN

(Current CFN + (250 – TTI/10msec))mod 256

MEASUREMENT CONTROL (Step 4)(TDD)

Information Element

Value/remark

Measurement Identity

3

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Event triggered

Additional measurements list

Not Present

CHOICE measurement type

– inter-RAT measurement

– inter-RAT measurement object list

CHOICE Inter-RAT Cell Removal

Remove all inter-RAT cells

-Remove all inter-RAT cells

(No Data)

New inter-RAT cells (1 to <MaxCellMeas>)

– inter-RAT cell id

0

CHOICE Radio Access Technology

GSM

– Cell individual offset

0

– Cell selection and re-selection info

Not present

– BSIC

BSIC1

– Band indicator

GSM/DCS-1800 or GSM/PCS-1900 (dependent on band used)

– BCCH ARFCN

Value according to the GSM band under test (see 3GPP 34.123-1 table 6.5 for details on the ARFCN)

– inter-RAT cell id

1

CHOICE Radio Access Technology

GSM

– Cell individual offset

0

– Cell selection and re-selection info

Not present

– BSIC

BSIC2

– Band indicator

GSM/DCS-1800 or GSM/PCS-1900 (dependent on band used)

– BCCH ARFCN

Value according to the GSM band under test (see 3GPP 34.123-1 table 6.5 for details on the ARFCN)

– Cell for measurement

Not present

– inter-RAT measurement quantity

– Measurement quantity for UTRAN quality estimate

Not included

CHOICE system

GSM

– Measurement quantity

GSM carrier RSSI

– Filter coefficient

0

– BSIC verification required

required

– inter-RAT reporting quantity

CHOICE system

GSM

– Observed time difference to GSM

FALSE

cell reporting indicator

– GSM carrier RSSI reporting indicator

TRUE

CHOICE report criteria

– Inter-RAT measurements reporting criteria

– Parameters required for each event

(1 to<maxMeasEvent>)

– Inter-RAT event identity

3b

– Threshold own system

Not included

– W

Not included

– Threshold other system

-80

– Hysteresis

2 (1 dB)

– Time to Trigger

60 ms

– Reporting cell status

Report cells within active set or within virtual active set or of the other RAT

– Maximum number of reported cells

3

MEASUREMENT REPORT (Step 7)

Information Element

Value/remark

Version

Measurement identity

Check to see if set to 3

Measured Results

– CHOICE measurement

Check to see if set to "Inter-RAT measured results list"

– Inter-RAT measured result list

– CHOICE system

GSM

– Measured GSM cells

Check that measurement results for two GSM cells are included

– GSM carrier RSSI

Check that measurement result is reasonable. RXLEV is mapped to a value between 0 and 63. The RSSI bits are numbered b0 to b5, where b0 is the least significant bit. When mapping the RXLEV value to the RSSI bit string, the first/ leftmost bit of the bit string contains the most significant bit.

CHOICE BSIC

Check it is set to verified BSIC

– inter-RAT cell id

Check that it is set to 1

– Observed time difference to GSM cell

Check that the IE is not included

R99 and Rel-4 only

– GSM carrier RSSI

Check that measurement result is reasonable

CHOICE BSIC

Verified BSIC

– inter-RAT cell id

Check that it is set to 0.

– Observed time difference to GSM cell

Check that the IE is not present

R99 and Rel-4 only

Measured results on RACH

Check that not present

Additional Measured results

Check that not present

Event results

Check that the IE is included

– CHOICE event result

Check that this is set to inter-RAT measurement event results

– Inter-RAT event identity

Check that this is set to 3b

– Cells to report (1 to <maxCellMeas>)

Check that <maxCellMeas> is set to 1

– CHOICE BSIC

Check that this is set to verified BSIC

– Inter-RAT cell id

Check that this is set to 0.

MEASUREMENT REPORT (Step 7) (1.28 Mcps TDD)

Information Element

Value/remark

Version

Measurement identity

Check to see if set to 3

Measured Results

Check that not present

Measured results on RACH

Check that not present

Additional Measured results

Check that not present

Non Critical Extensions

– Additional Measured results – LCR

– CHOICE measurement

Check to see if set to "Inter-RAT measured results list"

– Inter-RAT measured result list

– CHOICE system

GSM

– Measured GSM cells

Check that measurement results for two GSM cells are included

– GSM carrier RSSI

Check that measurement result is reasonable. RXLEV is mapped to a value between 0 and 63. The RSSI bits are numbered b0 to b5, where b0 is the least significant bit. When mapping the RXLEV value to the RSSI bit string, the first/ leftmost bit of the bit string contains the most significant bit.

CHOICE BSIC

Check it is set to verified BSIC

– inter-RAT cell id

Check that it is set to 1

– Observed time difference to GSM cell

Check that the IE is not included

R99 and Rel-4 only

– GSM carrier RSSI

Check that measurement result is reasonable

CHOICE BSIC

Verified BSIC

– inter-RAT cell id

Check that it is set to 0.

– Observed time difference to GSM cell

Check that the IE is not present

R99 and Rel-4 only

Event results

Check that the IE is included

– CHOICE event result

Check that this is set to inter-RAT measurement event results

– Inter-RAT event identity

Check that this is set to 3b

– Cells to report (1 to <maxCellMeas>)

Check that <maxCellMeas> is set to 1

– CHOICE BSIC

Check that this is set to verified BSIC

– Inter-RAT cell id

Check that this is set to 0.

MEASUREMENT CONTROL (Step 8)

Information Element

Value/remark

Measurement Identity

3

Measurement Command

Modify

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Not present

– Periodic Reporting / Event Trigger Reporting Mode

Not present

Additional measurements list

Not Present

CHOICE measurement type

– inter-RAT measurement

– inter-RAT measurement object list

CHOICE Inter-RAT Cell Removal

Remove no inter-RAT cells

New inter-RAT cells (1 to <MaxCellMeas>)

– inter-RAT cell id

Not present

CHOICE Radio Access Technology

GSM

– Cell individual offset

0

– Cell selection and re-selection info

Not present

– BSIC

BSIC3

– Band indicator

GSM/DCS-1800 or GSM/PCS-1900 (dependent on band used)

– BCCH ARFCN

Value according to the GSM band under test (see 3GPP 34.123-1 table 6.5 for details on the ARFCN)

– Cell for measurement

Not present

– inter-RAT measurement quantity

Not present

CHOICE report criteria

– Inter-RAT measurements reporting criteria

– Parameters required for each event (1 to<maxMeasEvent>)

Not Present

Physical channel information elements

Not present

MEASUREMENT REPORT (Step 9)

Information Element

Value/remark

Version

Measurement identity

Check to see if set to 3

Measured Results

– CHOICE measurement

Check to see if set to "Inter-RAT measured results list"

– Inter-RAT measured result list

– CHOICE system

GSM

– Measured GSM cells

Check that measurement results for three GSM cells are included

– GSM carrier RSSI

Check that measurement result is reasonable. RXLEV is mapped to a value between 0 and 63. The RSSI bits are numbered b0 to b5, where b0 is the least significant bit. When mapping the RXLEV value to the RSSI bit string, the first/ leftmost bit of the bit string contains the most significant bit.

CHOICE BSIC

Check it is set to verified BSIC

– inter-RAT cell id

Check that it is set to 1

– Observed time difference to GSM cell

Check that the IE is not included

R99 and Rel-4 only

– GSM carrier RSSI

Check that measurement result is reasonable

CHOICE BSIC

Verified BSIC

– inter-RAT cell id

Check that is set to 0 or 2.

– Observed time difference to GSM cell

Check that the IE is not present

R99 and Rel-4 only

– GSM carrier RSSI

Check that measurement result is reasonable

CHOICE BSIC

Verified BSIC

– inter-RAT cell id

Check that is set to 0 or 2 and that this inter-RAT cell id is different from the two previous inter-RAT cell id.

– Observed time difference to GSM cell

Check that the IE is not present

R99 and Rel-4 only

Measured results on RACH

Check that not present

Additional Measured results

Check that not present

Event results

Check that the IE is included

– CHOICE event result

Check that this is set to inter-RAT measurement event results

– Inter-RAT event identity

Check that this is set to 3b

– Cells to report (1 to <maxCellMeas>)

Check that <maxCellMeas> is set to 1

– CHOICE BSIC

Check that this is set to verified BSIC

– Inter-RAT cell id

Check that this is set to 2.

MEASUREMENT REPORT (Step 9) (1.28 Mcps TDD)

Information Element

Value/remark

Version

Measurement identity

Check to see if set to 3

Measured Results

Check that not present

Measured results on RACH

Check that not present

Additional Measured results

Check that not present

Non Critical Extensions

– Additional Measured results – LCR

– CHOICE measurement

Check to see if set to "Inter-RAT measured results list"

– Inter-RAT measured result list

– CHOICE system

GSM

– Measured GSM cells

Check that measurement results for three GSM cells are included

– GSM carrier RSSI

Check that measurement result is reasonable. RXLEV is mapped to a value between 0 and 63. The RSSI bits are numbered b0 to b5, where b0 is the least significant bit. When mapping the RXLEV value to the RSSI bit string, the first/ leftmost bit of the bit string contains the most significant bit.

CHOICE BSIC

Check it is set to verified BSIC

– inter-RAT cell id

Check that it is set to 1

– Observed time difference to GSM cell

Check that the IE is not included

R99 and Rel-4 only

– GSM carrier RSSI

Check that measurement result is reasonable

CHOICE BSIC

Verified BSIC

– inter-RAT cell id

Check that is set to 0 or 2.

– Observed time difference to GSM cell

Check that the IE is not present

R99 and Rel-4 only

– GSM carrier RSSI

Check that measurement result is reasonable

CHOICE BSIC

Verified BSIC

– inter-RAT cell id

Check that is set to 0 or 2 and that this inter-RAT cell id is different from the two previous inter-RAT cell id.

– Observed time difference to GSM cell

Check that the IE is not present

R99 and Rel-4 only

Event results

Check that the IE is included

– CHOICE event result

Check that this is set to inter-RAT measurement event results

– Inter-RAT event identity

Check that this is set to 3b

– Cells to report (1 to <maxCellMeas>)

Check that <maxCellMeas> is set to 1

– CHOICE BSIC

Check that this is set to verified BSIC

– Inter-RAT cell id

Check that this is set to 2.

8.4.1.34.5 Test requirement

Between instants T0 and T1, the UE shall not send any MEASUREMENT REPORT message to the SS.

Event 3b shall be triggered in the UE (i.e. the transmission of the first MEASUREMENT REPORT message shall begin) after instant T1.

After the reception by the UE of the second MEASUREMENT CONTROL message, the UE shall begin to transmit the second MEASUREMENT REPORT message (since the signal strength for GSM cell 3 is below the threshold for triggering event 3b).

8.4.1.35 Measurement Control and Report: Inter-RAT measurement, event 3c

8.4.1.35.1 Definition

8.4.1.35.2 Conformance requirement

When event 3c is configured in the UE within a measurement, the UE shall:

1> if the other RAT is GSM, and if IE "BSIC verification required" is set to "required":

2> if equation 1 below has been fulfilled for a time period indicated by "time to trigger" for one or several GSM cells that match any of the BCCH ARFCN and BSIC combinations considered in that inter-RAT measurement:

3> if the inter-RAT cell id of any of those GSM cell is not stored in the variable TRIGGERED_3C_EVENT:

4> store the Inter-RAT cell ids of the GSM cells that triggered the event and that were not previously stored in the variable TRIGGERED_3C_EVENT into that variable;

4> send a measurement report with IEs set as below:

5> set in "inter-RAT measurement event result": "inter-RAT event identity" to "3c", "CHOICE BSIC" to "verified BSIC" and "Inter-RAT cell id" to the GSM cells that triggered the event (best one first);

5> set the IE "measured results" and the IE "additional measured results" according to 8.4.2, not taking into account the cell individual offset;

2> if equation 2 below is fulfilled for a GSM cell whose inter-RAT cell id is stored in the variable TRIGGERED_3C_EVENT:

3> remove the inter-RAT cell id of that GSM cell from the variable TRIGGERED_3C_EVENT.

1> if the other RAT is GSM, and if IE "BSIC verification required" is set to "not required":

2> if equation 1 below has been fulfilled for a time period indicated by "time to trigger" for one or several of the BCCH ARFCNs considered in that inter-RAT measurement:

3> if any of those BCCH ARFCN is not stored into the variable TRIGGERED_3C_EVENT:

4> store the BCCH ARFCNs that triggered the event and that were not previously stored in the variable TRIGGERED_3C_EVENT into that variable;

4> send a measurement report with IEs set as below:

5> set in "inter-RAT measurement event result": "inter-RAT event identity" to "3c", "CHOICE BSIC" to "non verified BSIC" and "BCCH ARFCN" to BCCH ARFCNs that triggered the event (best one first);

5> set the IE "measured results" and the IE "additional measured results" according to TS 25.331 subclause 8.4.2, not taking into account the cell individual offset;

2> if equation 2 is fulfilled for a BCCH ARFCN that is stored in the variable TRIGGERED_3C_EVENT:

3> remove that BCCH ARFCN from the variable TRIGGERED_3C_EVENT.

Triggering condition:

Equation 1:

The variables in the formula are defined as follows:

MOther RAT is the measurement quantity for the cell of the other system. MOther RAT is expressed in dBm.

CIOOther RAT is the cell individual offset for the cell of the other system.

TOther RAT is the absolute threshold that applies for the other system in that measurement.

H3c is the hysteresis parameter for event 3c.

Leaving triggered state condition:

Equation 2:

The variables in the formula are defined as follows:

MOther RAT is the measurement quantity for the cell of the other system. MOther RAT is expressed in dBm.

CIOOther RAT is the cell individual offset for the cell of the other system.

TOther RAT is the absolute threshold that applies for the other system in that measurement.

H3c is the hysteresis parameter for event 3c.

Reference

3GPP TS 25.331 clauses 14.3.1.3, 8.4.2.2.

8.4.1.35.3 Test Purpose

1 To confirm that the UE sends MEASUREMENT REPORT message if event 3c is configured, and if the quality of the other system becomes better than the given threshold for event 3c.

2 To confirm that no other UE MEASUREMENT REPORT message is sent by the UE for a cell that has already triggered event 3c as long as the hysteresis condition for triggering once again event 3c has not been fulfilled.

8.4.1.35.4 Method of test

Initial Condition

System simulator: 1 UTRAN FDD cell (or TDD cell) and 2 GSM cells. The initial configurations of the 2 GSM cells in the SS shall follow the values indicated in the column marked T0. The table is found in "Test procedure".

UE: CELL CS-DCCH+DTCH_DCH (State 6-9) or PS-DCCH+DTCH_DCH (State 6-10) in cell 1 (UTRA) as specified in clause 7.4 of TS 34.108, depending on the CN domain supported by the UE.

Related ICS/IXIT statements

– Compressed mode required yes/no

– UE supports GSM-P, GSM-E, GSM-DCS, GSM-450, GSM-480, GSM-PCS, GSM-850.

Test procedure

Table 8.4.1.35.4-1

Parameter

Unit

Cell 1 (GSM)

Cell 2 (GSM)

T0

T1

T2

T3

T0

T1

T2

T3

Test Channel

#

GSM Ch.1

GSM Ch.2

BCCH ARFCN

#

Value according to the GSM band under test (see 3GPP 34.123-1 table 6.5 for details on the ARFCN)

Value according to the GSM band under test (see 3GPP 34.123-1 table 6.5 for details on the ARFCN)

CELL identity

#

0

1

BSIC

#

BSIC 1

BSIC 2

RF Signal Level

dBm

-90

-75

-80

-75

-75

-75

-75

-75

The table above illustrate the downlink power to be applied for the two cells at various instants of the test execution. Column marked "T0" denotes the initial conditions, while column marked "T1", "T2" and "T3" indicate the values to be applied subsequently.

The UE is initially in CELL_DCH state as specified in clause 7.4 of TS 34.108. UTRA cell 1 is the only cell in the active set of the UE. If the UE requires compressed mode (refer ICS/IXIT), the SS sends a PHYSICAL CHANNEL RECONFIGURATION message to the UE to configure the compressed mode pattern sequence parameters to the UE. Three compressed mode patterns are configured, according to the message specified below. When the PHYSICAL CHANNEL RECONFIGURATION COMPLETE is received from the UE, the SS sends a MEASUREMENT CONTROL message to the UE, to set up inter-RAT measurements. Event 3c is set up in this message, and if the UE requires compressed mode (refer ICS/IXIT), compressed mode is activated.

At instant T1, the RF signal strength for GSM cell 1 increases as described in table 8.4.1.35.4-1.

At instant T2, the RF signal strength for GSM cell 1 drops as described in table 8.4.1.35.4-1, and at instant T3, it increases again to its previous level. SS calls for generic procedure C.3 to check that UE is in CELL_DCH state.

Expected Sequence

Step

Direction

Message

Comment

UE

SS

1

The UE is brought to the CELL_DCH state in the cell 1.

If the UE does not require compressed mode (refer ICS/IXIT), then goto step 4.

2

PHYSICAL CHANNEL RECONFIGURATION

Compressed mode pattern sequence parameters are loaded to UE.

3

PHYSICAL CHANNEL RECONFIGURATION COMPLETE

4

MEASUREMENT CONTROL

SS configures event 3c in the UE. If the UE requires compressed mode (refer ICS/IXIT), compressed mode is started.

5

SS waits for approximately 10 seconds and verifies that no MEASUREMENT REPORT messages are detected on uplink DCCH.

6

SS re-adjusts the downlink transmission power settings according to columns "T1" in table 8.4.1.35.4-1.

7

MEASUREMENT REPORT

After about 0.9 s, the UE sends a MEASUREMENT REPORT to SS triggered by event 3c.

8

SS re-adjusts the downlink transmission power settings according to columns "T2" in table 8.4.1.35.4-1.

9

SS re-adjusts the downlink transmission power settings according to columns "T3" in table 8.4.1.35.4-1.

10

SS waits for approximately 10 seconds and verifies that no MEASUREMENT REPORT messages are detected on uplink DCCH.

11



CALL C.3

If the test result of C.3 indicates that UE is in CELL_DCH state, the test passes, otherwise it fails.

Specific Message Content

PHYSICAL CHANNEL RECONFIGURATION (Step 2)

Use the same message sub-type in clause 9 of TS 34.108 titled "Non speech in CS" or "Speech in CS" or "Packet to CELL_DCH from CELL_DCH in PS, with Scrambling code change set to Default1 and with the following exceptions:

Information Element

Value/remark

Version

Downlink information common for all radio links

– DPCH compressed mode info

– TGPSI

1

– TGPS Status Flag

Deactivate

– TGCFN

Not present

– Transmission gap pattern sequence configuration parameters

– TGMP

GSM Carrier RSSI Measurement

– TGPRC

Infinity

– TGSN

4

– TGL1

7

– TGL2

Not present

– TGD

undefined

– TGPL1

12

– TGPL2

Not present

R99 and REL-4 only

– RPP

Mode 0

– ITP

Mode 0

CHOICE UL/DL Mode

UL&DL or UL-only or DL-only (depends on UE’s Measurement capability)

– Downlink compressed mode method

SF/2

– Uplink compressed mode method

SF/2

– Downlink frame type

A

– DeltaSIR1

10 (1.0)

– DeltaSIRAfter1

5 (0.5)

– DeltaSIR2

Not Present

– DeltaSIR2After2

Not Present

– N identify abort

Not Present

– T Reconfirm abort

Not Present

– TGPSI

2

– TGPS Status Flag

Deactivate

– TGCFN

Not present

– Transmission gap pattern sequence configuration parameters

– TGMP

GSM BSIC identification

– TGPRC

Infinity

– TGSN

4

– TGL1

7

– TGL2

Not present

– TGD

undefined

– TGPL1

8

– TGPL2

Not present

R99 and REL-4 only

– RPP

Mode 0

– ITP

Mode 0

CHOICE UL/DL Mode

UL&DL or UL-only or DL-only (depends on UE’s Measurement capability)

– Downlink compressed mode method

SF/2

– Uplink compressed mode method

SF/2

– Downlink frame type

A

– DeltaSIR1

10 (1.0)

– DeltaSIRAfter1

5 (0.5)

– DeltaSIR2

Not Present

– DeltaSIR2After2

Not Present

– N identify abort

66

– T Reconfirm abort

Not Present

– TGPSI

3

– TGPS Status Flag

Deactivate

– TGCFN

Not present

– Transmission gap pattern sequence configuration parameters

– TGMP

GSM BSIC re-confirmation

– TGPRC

Infinity

– TGSN

4

– TGL1

7

– TGL2

Not present

– TGD

undefined

– TGPL1

8

– TGPL2

Not present

R99 and REL-4 only

– RPP

Mode 0

– ITP

Mode 0

CHOICE UL/DL Mode

UL&DL or UL-only or DL-only (depends on UE’s Measurement capability)

– Downlink compressed mode method

SF/2

– Uplink compressed mode method

SF/2

– Downlink frame type

A

– DeltaSIR1

10 (1.0)

– DeltaSIRAfter1

5 (0.5)

– DeltaSIR2

Not Present

– DeltaSIR2After2

Not Present

– N identify abort

Not Present

– T Reconfirm abort

10 (5 s)

Downlink information per radio link list

– Choice mode

FDD

– Primary CPICH info

– Primary scrambling code

Ref. to the Default setting in clause 6.1 (FDD)

– PDSCH with SHO DCH info

Not Present

R99 and Rel-4 only

– PDSCH code mapping

Not Present

R99 and Rel-4 only

– Serving HS-DSCH radio link indicator

FALSE

Rel-5

– Serving E-DCH radio link indicator

FALSE

Rel-6

– Downlink DPCH info for each RL

– CHOICE mode

FDD

– Primary CPICH usage for channel estimation

Primary CPICH may be used

– DPCH frame offset

Set to value : Default DPCH Offset Value (as currently stored in SS) mod 38 400

– Secondary CPICH info

Not Present

– DL channelisation code

– Secondary scrambling code

5

– Spreading factor

Reference to clause 6.10 Parameter Set

– Code number

0

– Scrambling code change

Set to value Default1: No code change (if the UE has a compressed mode pattern sequence configured in variable TGPS_IDENTITY or included in the message including IE "Downlink DPCH info for each RL", which is using compressed mode method "SF/2")

– TPC combination index

0

– SSDT Cell Identity

Not Present

R99 and Rel-4 only

– Closed loop timing adjustment mode

Not Present

– E-AGCH Info

Not Present

Rel-6

– E-HICH Information

Not Present

Rel-6

– E-RGCH Information

Not Present

Rel-6

– SCCPCH information for FACH

Not Present

R99 and Rel-4 only

MEASUREMENT CONTROL (Step 4)(FDD)

Information Element

Value/remark

Measurement Identity

3

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Event triggered

Additional measurements list

Not Present

CHOICE measurement type

– inter-RAT measurement

– inter-RAT measurement object list

CHOICE Inter-RAT Cell Removal

Remove all inter-RAT cells

-Remove all inter-RAT cells

(No Data)

New inter-RAT cells (1 to <MaxCellMeas>)

– inter-RAT cell id

0

CHOICE Radio Access Technology

GSM

– Cell individual offset

10

– Cell selection and re-selection info

Not present

– BSIC

BSIC1

– Band indicator

GSM/DCS-1800 or GSM/PCS-1900 (dependent on band used)

– BCCH ARFCN

Value according to the GSM band under test (see 3GPP 34.123-1 table 6.5 for details on the ARFCN)

– inter-RAT cell id

1

CHOICE Radio Access Technology

GSM

– Cell individual offset

-3

– Cell selection and re-selection info

Not present

– BSIC

BSIC2

– Band indicator

GSM/DCS-1800 or GSM/PCS-1900 (dependent on band used)

– BCCH ARFCN

Value according to the GSM band under test (see 3GPP 34.123-1 table 6.5 for details on the ARFCN)

– Cell for measurement

Not present

– inter-RAT measurement quantity

– Measurement quantity for UTRAN quality estimate

Not included

CHOICE system

GSM

– Measurement quantity

GSM carrier RSSI

– Filter coefficient

0

– BSIC verification required

required

– inter-RAT reporting quantity

CHOICE system

GSM

– Observed time difference to GSM cell reporting indicator

FALSE

– GSM carrier RSSI reporting indicator

TRUE

CHOICE report criteria

– Inter-RAT measurements reporting criteria

– Parameters required for each event

(1 to<maxMeasEvent>)

– Inter-RAT event identity

3c

– Threshold own system

Not included

– W

Not included

– Threshold other system

-74

– Hysteresis

5 (2.5 dB)

– Time to Trigger

100 ms

– Reporting cell status

Report cells within active set or within virtual active set or of the other RAT

– Maximum number of reported cells

2

Physical channel information elements

– DPCH compressed mode status info

If the UE requires compressed mode (refer ICS/IXIT), this IE is present and contains the IEs as follows. If the UE does not require compressed mode (refer ICS/IXIT), this IE is not present.

– TGPS reconfiguration CFN

(Current CFN + (250 – TTI/10msec))mod 256

– Transmission gap pattern sequence (1 to <MaxTGPS>)

– TGPSI

1

– TGPS status flag

Activate

– TGCFN

(Current CFN + (252 – TTI/10msec))mod 256

– TGPSI

2

– TGPS status flag

Activate

– TGCFN

(Current CFN + (254 – TTI/10msec))mod 256

– TGPSI

3

– TGPS status flag

Activate

– TGCFN

(Current CFN + (250 – TTI/10msec))mod 256

MEASUREMENT CONTROL (Step 4)(TDD)

Information Element

Value/remark

Measurement Identity

3

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Event triggered

Additional measurements list

Not Present

CHOICE measurement type

– inter-RAT measurement

– inter-RAT measurement object list

CHOICE Inter-RAT Cell Removal

Remove all inter-RAT cells

-Remove all inter-RAT cells

(No Data)

New inter-RAT cells (1 to <MaxCellMeas>)

– inter-RAT cell id

0

CHOICE Radio Access Technology

GSM

– Cell individual offset

10

– Cell selection and re-selection info

Not present

– BSIC

BSIC1

– Band indicator

GSM/DCS-1800 or GSM/PCS-1900 (dependent on band used)

– BCCH ARFCN

Value according to the GSM band under test (see 3GPP 34.123-1 table 6.5 for details on the ARFCN)

– inter-RAT cell id

1

CHOICE Radio Access Technology

GSM

– Cell individual offset

-3

– Cell selection and re-selection info

Not present

– BSIC

BSIC2

– Band indicator

GSM/DCS-1800 or GSM/PCS-1900 (dependent on band used)

– BCCH ARFCN

Value according to the GSM band under test (see 3GPP 34.123-1 table 6.5 for details on the ARFCN)

– Cell for measurement

Not present

– inter-RAT measurement quantity

– Measurement quantity for UTRAN quality estimate

Not included

CHOICE system

GSM

– Measurement quantity

GSM carrier RSSI

– Filter coefficient

0

– BSIC verification required

required

– inter-RAT reporting quantity

CHOICE system

GSM

– Observed time difference to GSM cell reporting indicator

FALSE

– GSM carrier RSSI reporting indicator

TRUE

CHOICE report criteria

– Inter-RAT measurements reporting criteria

– Parameters required for each event

(1 to<maxMeasEvent>)

– Inter-RAT event identity

3c

– Threshold own system

Not included

– W

Not included

– Threshold other system

-74

– Hysteresis

5 (2.5 dB)

– Time to Trigger

100 ms

– Reporting cell status

Report cells within active set or within virtual active set or of the other RAT

– Maximum number of reported cells

2

MEASUREMENT REPORT (Step 7)

Information Element

Value/remark

Version

Measurement identity

Check to see if set to 3

Measured Results

– CHOICE measurement

Check to see if set to "Inter-RAT measured results list"

– Inter-RAT measured result list

– CHOICE system

GSM

– Measured GSM cells

Check that measurement results for two GSM cells are included

– GSM carrier RSSI

Check that measurement result is reasonable. RXLEV is mapped to a value between 0 and 63. The RSSI bits are numbered b0 to b5, where b0 is the least significant bit. When mapping the RXLEV value to the RSSI bit string, the first/ leftmost bit of the bit string contains the most significant bit.

CHOICE BSIC

Check it is set to verified BSIC

– inter-RAT cell id

Check that it is set to either 0 or 1

– Observed time difference to GSM cell

Check that the IE is not included

R99 and Rel-4 only

– GSM carrier RSSI

Check that measurement result is reasonable

CHOICE BSIC

Verified BSIC

– inter-RAT cell id

Check that is set to 1 if the previous inter-RAT cell id was set to 0 or to 0 if the previous cell if was set to 1.

– Observed time difference to GSM cell

Check that the IE is not present

R99 and Rel-4 only

Measured results on RACH

Check that not present

Additional Measured results

Check that not present

Event results

Check that the IE is included

– CHOICE event result

Check that this is set to inter-RAT measurement event results

– Inter-RAT event identity

Check that this is set to 3c

– Cells to report (1 to <maxCellMeas>)

Check that <maxCellMeas> is set to 1

– CHOICE BSIC

Check that this is set to verified BSIC

– Inter-RAT cell id

Check that this is set to 0.

MEASUREMENT REPORT (Step 7) (1.28 Mcps TDD)

Information Element

Value/remark

Version

Measurement identity

Check to see if set to 3

Measured Results

Check that not present

Measured results on RACH

Check that not present

Additional Measured results

Check that not present

Non Critical Extensions

– Additional Measured results – LCR

– CHOICE measurement

Check to see if set to "Inter-RAT measured results list"

– Inter-RAT measured result list

– CHOICE system

GSM

– Measured GSM cells

Check that measurement results for two GSM cells are included

– GSM carrier RSSI

Check that measurement result is reasonable. RXLEV is mapped to a value between 0 and 63. The RSSI bits are numbered b0 to b5, where b0 is the least significant bit. When mapping the RXLEV value to the RSSI bit string, the first/ leftmost bit of the bit string contains the most significant bit.

CHOICE BSIC

Check it is set to verified BSIC

– inter-RAT cell id

Check that it is set to either 0 or 1

– Observed time difference to GSM cell

Check that the IE is not included

R99 and Rel-4 only

– GSM carrier RSSI

Check that measurement result is reasonable

CHOICE BSIC

Verified BSIC

– inter-RAT cell id

Check that is set to 1 if the previous inter-RAT cell id was set to 0 or to 0 if the previous cell if was set to 1.

– Observed time difference to GSM cell

Check that the IE is not present

R99 and Rel-4 only

Event results

Check that the IE is included

– CHOICE event result

Check that this is set to inter-RAT measurement event results

– Inter-RAT event identity

Check that this is set to 3c

– Cells to report (1 to <maxCellMeas>)

Check that <maxCellMeas> is set to 1

– CHOICE BSIC

Check that this is set to verified BSIC

– Inter-RAT cell id

Check that this is set to 0.

8.4.1.35.5 Test requirement

After instant T1, since the cell individual offset for GSM cell 1 is +10 dB, event 3c shall be triggered in the UE, i.e. the UE shall begin to transmit a MEASUREMENT REPORT to the SS. Note that GSM cell 2 has not triggered event 3c even though the RF signal strength for GSM cell 2 is the same as for cell 1, because the cell individual offset for GSM cell 2 is -3 dB.

After instant T2, no MEASUREMENT REPORT shall be received from the UE, since GSM cell 1 has already triggered event 3c, and since the RF signal strength has not dropped enough for the leaving condition to be met.

8.4.1.36 Measurement Control and Report: Inter-RAT measurement, event 3d

8.4.1.36.1 Definition

8.4.1.36.2 Conformance requirement

When event 3d is configured in the UE within a measurement, the UE shall:

1> if the other RAT is GSM, and if IE "BSIC verification required" is set to "required":

2> when the measurement is initiated or resumed:

3> store in the variable BEST_CELL_3D_EVENT the Inter-RAT cell id of the GSM cell that has the best measured quantity among the GSM cells that match any of the BCCH ARFCN and BSIC combinations considered in that inter-RAT measurement

3> send a measurement report with IE set as below:

4> set in "inter-RAT measurement event result": "inter-RAT event identity" to "3d", "CHOICE BSIC" to "verified BSIC" and "Inter-RAT cell id" to the GSM cell that is stored in the variable BEST_CELL_3D_EVENT;

4> set the IE "measured results" and the IE "additional measured results" according to TS 25.331 subclause 8.4.2, not taking into account the cell individual offset;

2> if equation 1 has been fulfilled for a time period indicated by "time to trigger" for a GSM cell that is different from the one stored in BEST_CELL_3D_EVENT and that matches any of the BCCH ARFCN and BSIC combinations considered in that inter-RAT measurement:

3> store the Inter-RAT cell id of that GSM cell in the variable BEST_CELL_3D_EVENT;

3> send a measurement report with IEs set as below:

4> set in "inter-RAT measurement event result": "inter-RAT event identity" to "3d", "CHOICE BSIC" to "verified BSIC" and "Inter-RAT cell id" to the GSM cell is now stored in BEST_CELL_3D_EVENT;

4> set the IE "measured results" and the IE "additional measured results" according to TS 25.331 subclause 8.4.2, not taking into account the cell individual offset;

1> if the other RAT is GSM, and if IE "BSIC verification required" is set to "not required":

2> when the measurement is initiated or resumed:

3> store in the variable BEST_CELL_3D_EVENT the BCCH ARFCN of the GSM cell that has the best measured quantity among the BCCH ARFCNs considered in that inter-RAT measurement;

3> send a measurement report with IE set as below:

4> set in "inter-RAT measurement event result": "inter-RAT event identity" to "3d", "CHOICE BSIC" to "non verified BSIC" and "BCCH ARFCN" to the BCH ARFCN that is stored in the variable BEST_CELL_3D_EVENT;

4> set the IE "measured results" and the IE "additional measured results" according to TS 25.331 subclause 8.4.2, not taking into account the cell individual offset;

2> if equation 1 below has been fulfilled for a time period indicated by "time to trigger" for one of the BCCH ARFCNs considered in that inter-RAT measurement and different from the one stored in BEST_CELL_3D_EVENT:

3> store the BCCH ARFCN of that GSM cell in the variable BEST_CELL_3D_EVENT;

3> send a measurement report with IEs set as below:

4> set in "inter-RAT measurement event result": "inter-RAT event identity" to "3d", "CHOICE BSIC" to "non verified BSIC" and "BCCH ARFCN" to the BCCH ARFCN that is now stored in the variable BEST_CELL_3D_EVENT;

4> set the IE "measured results" and the IE "additional measured results" according to TS 25.331 subclause 8.4.2, not taking into account the cell individual offset;

Equation 1:

The variables in the formula are defined as follows:

MNew is the measurement quantity for a GSM cell that is not stored in the variable BEST_CELL_3D.

MBest is the measurement quantity for a GSM cell that is stored in the variable BEST_CELL_3D.

H3d is the hysteresis parameter for event 3d.

Reference

3GPP TS 25.331 clause 14.3.1.4.

8.4.1.36.3 Test Purpose

1. To confirm that the UE sends MEASUREMENT REPORT message if event 3d is configured, and if the best cell changes in the other system. To confirm that no other UE MEASUREMENT REPORT message is sent by the UE for a cell that has already triggered event 3d as long as the hysteresis condition for triggering once again event 3d has not been fulfilled.

8.4.1.36.4 Method of test

Initial Condition

System simulator: 1 UTRAN FDD cell (or TDD cell) and 2 GSM cells. The initial configurations of the 2 GSM cells in the SS shall follow the values indicated in the column marked T0. The table is found in "Test procedure".

UE: CS-DCCH+DTCH_DCH (State 6-9) or PS-DCCH+DTCH_DCH (State 6-10) in cell 1 (UTRA) as specified in clause 7.4 of TS 34.108, depending on the CN domain supported by the UE.

Related ICS/IXIT statements

– Compressed mode required yes/no

– UE supports GSM-P, GSM-E, GSM-DCS, GSM-450, GSM-480, GSM-PCS, GSM-850.

Test procedure

Table 8.4.1.36.4-1

Parameter

Unit

Cell 1 (GSM)

Cell 2 (GSM)

T0

T1

T0

T1

Test Channel

#

GSM Ch.1

GSM Ch.2

BCCH ARFCN

#

Value according to the GSM band under test (see 3GPP 34.123-1 table 6.5 for details on the ARFCN)

Value according to the GSM band under test (see 3GPP 34.123-1 table 6.5 for details on the ARFCN)

CELL identity

#

0

1

BSIC

#

BSIC 1

BSIC 2

RF Signal Level

dBm

-70

-90

-90

-70

The table above illustrate the downlink power to be applied for the two cells at various instants of the test execution. Column marked "T0" denotes the initial conditions, while column marked "T1"indicates the values to be applied subsequently.

The UE is initially in CELL_DCH state as specified in clause 7.4 of TS 34.108. UTRA cell 1 is the only cell in the active set of the UE. If the UE requires compressed mode (refer ICS/IXIT), the SS sends a PHYSICAL CHANNEL RECONFIGURATION message to the UE to configure the compressed mode pattern sequence parameters to the UE. Three compressed mode patterns are configured, according to the message specified below. When the PHYSICAL CHANNEL RECONFIGURATION COMPLETE is received from the UE, the SS sends a MEASUREMENT CONTROL message to the UE, to set up inter-RAT measurements. Event 3d is set up in this message, and if the UE requires compressed mode (refer ICS/IXIT), compressed mode is activated.

At instant T1, the RF signal strength for GSM cell 1 increases while the RF signal strength for GSM cell 2 decreases as described in table 8.4.1.36.4-1.

A MEASUREMENT CONTROL is then sent to the UE that releases the inter-RAT measurement, and deactivates compressed mode. SS calls for generic procedure C.3 to check that UE is in CELL_DCH state.

Expected Sequence

Step

Direction

Message

Comment

UE

SS

1

The UE is brought to the CELL_DCH state in the cell 1.

If the UE does not require compressed mode (refer ICS/IXIT), then goto step 4.

2

PHYSICAL CHANNEL RECONFIGURATION

Compressed mode pattern sequence parameters are loaded to UE.

3

PHYSICAL CHANNEL RECONFIGURATION COMPLETE

4

MEASUREMENT CONTROL

SS configures event 3d in the UE. If the UE requires compressed mode (refer ICS/IXIT), compressed mode is started.

5

MEASUREMENT REPORT

The UE sends a MEASUREMENT REPORT to UTRAN indicating which is/are the best GSM cell/Cells just after the initiation of the measurement

SS should wait long enough for the reception of this message as UE that needs compressed mode takes time to activate compressed mode patterns as well as complete BSIC verification before sending the report

6

SS re-adjusts the downlink transmission power settings according to columns "T1" in tables 8.4.1.36.4-1.

7

MEASUREMENT REPORT

The UE sends a MEASUREMENT REPORT to SS triggered by event 3d. SS should wait long enough for the reception of this message as UE that needs compressed mode takes time to complete BSIC verification before sending the report

8

MEASUREMENT CONTROL

SS releases the inter-RAT measurements, and, if the UE requires compressed mode (refer ICS/IXIT), deactivates compressed mode.

9

If the UE requires compressed mode (refer ICS/IXIT), SS checks that the UE has deactivated compressed mode.

10



CALL C.3

If the test result of C.3 indicates that UE is in CELL_DCH state, the test passes, otherwise it fails.

Specific Message Content

PHYSICAL CHANNEL RECONFIGURATION (Step 2)

Use the same message sub-type in clause 9 of TS 34.108 titled "Non speech in CS" or "Speech in CS" or "Packet to CELL_DCH from CELL_DCH in PS, with Scrambling code change set to Default1 and with the following exceptions:

Information Element

Value/remark

Version

Downlink information common for all radio links

– DPCH compressed mode info

– TGPSI

1

– TGPS Status Flag

Deactivate

– TGCFN

Not present

– Transmission gap pattern sequence configuration parameters

– TGMP

GSM Carrier RSSI Measurement

– TGPRC

Infinity

– TGSN

4

– TGL1

7

– TGL2

Not present

– TGD

undefined

– TGPL1

12

– TGPL2

Not present

R99 and REL-4 only

– RPP

Mode 0

– ITP

Mode 0

CHOICE UL/DL Mode

UL&DL or UL-only or DL-only (depends on UE’s Measurement capability) depends on UE’s Measurement capability)

– Downlink compressed mode method

SF/2

– Uplink compressed mode method

SF/2

– Downlink frame type

A

– DeltaSIR1

10 (1.0)

– DeltaSIRAfter1

5 (0.5)

– DeltaSIR2

Not Present

– DeltaSIR2After2

Not Present

– N identify abort

Not Present

– T Reconfirm abort

Not Present

– TGPSI

2

– TGPS Status Flag

Deactivate

– TGCFN

Not present

– Transmission gap pattern sequence configuration parameters

– TGMP

GSM BSIC identification

– TGPRC

Infinity

– TGSN

4

– TGL1

7

– TGL2

Not present

– TGD

undefined

– TGPL1

8

– TGPL2

Not present

R99 and REL-4 only

– RPP

Mode 0

– ITP

Mode 0

CHOICE UL/DL Mode

UL&DL or UL-only or DL-only (depends on UE’s Measurement capability)

– Downlink compressed mode method

SF/2

– Uplink compressed mode method

SF/2

– Downlink frame type

A

– DeltaSIR1

10 (1.0)

– DeltaSIRAfter1

5 (0.5)

– DeltaSIR2

Not Present

– DeltaSIR2After2

Not Present

– N identify abort

66

– T Reconfirm abort

Not Present

– TGPSI

3

– TGPS Status Flag

Deactivate

– TGCFN

Not present

– Transmission gap pattern sequence configuration parameters

– TGMP

GSM BSIC re-confirmation

– TGPRC

Infinity

– TGSN

4

– TGL1

7

– TGL2

Not present

– TGD

undefined

– TGPL1

8

– TGPL2

Not present

R99 and REL-4 only

– RPP

Mode 0

– ITP

Mode 0

CHOICE UL/DL Mode

UL&DL or UL-only or DL-only (depends on UE’s Measurement capability)

– Downlink compressed mode method

SF/2

– Uplink compressed mode method

SF/2

– Downlink frame type

A

– DeltaSIR1

10 (1.0)

– DeltaSIRAfter1

5 (0.5)

– DeltaSIR2

Not Present

– DeltaSIR2After2

Not Present

– N identify abort

Not Present

– T Reconfirm abort

10 (5 s)

Downlink information per radio link list

– Choice mode

FDD

– Primary CPICH info

– Primary scrambling code

Ref. to the Default setting in clause 6.1 (FDD)

– PDSCH with SHO DCH info

Not Present

R99 and Rel-4 only

– PDSCH code mapping

Not Present

R99 and Rel-4 only

– Serving HS-DSCH radio link indicator

FALSE

Rel-5

– Serving E-DCH radio link indicator

FALSE

Rel-6

– Downlink DPCH info for each RL

– CHOICE mode

FDD

– Primary CPICH usage for channel estimation

Primary CPICH may be used

– DPCH frame offset

Set to value : Default DPCH Offset Value (as currently stored in SS) mod 38 400

– Secondary CPICH info

Not Present

– DL channelisation code

– Secondary scrambling code

5

– Spreading factor

Reference to clause 6.10 Parameter Set

– Code number

0

– Scrambling code change

Set to value Default1: No code change (if the UE has a compressed mode pattern sequence configured in variable TGPS_IDENTITY or included in the message including IE "Downlink DPCH info for each RL", which is using compressed mode method "SF/2")

– TPC combination index

0

– SSDT Cell Identity

Not Present

R99 and Rel-4 only

– Closed loop timing adjustment mode

Not Present

– E-AGCH Info

Not Present

Rel-6

– E-HICH Information

Not Present

Rel-6

– E-RGCH Information

Not Present

Rel-6

– SCCPCH information for FACH

Not Present

R99 and Rel-4 only

MEASUREMENT CONTROL (Step 4)(FDD)

Information Element

Value/remark

Measurement Identity

3

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Event triggered

Additional measurements list

Not Present

CHOICE measurement type

– inter-RAT measurement

– inter-RAT measurement object list

CHOICE Inter-RAT Cell Removal

Remove all inter-RAT cells

-Remove all inter-RAT cells

(No Data)

New inter-RAT cells (1 to <MaxCellMeas>)

– inter-RAT cell id

Not present

CHOICE Radio Access Technology

GSM

– Cell individual offset

0

– Cell selection and re-selection info

Not present

– BSIC

BSIC1

– Band indicator

GSM/DCS-1800 or GSM/PCS-1900 (dependent on band used)

– BCCH ARFCN

Value according to the GSM band under test (see 3GPP 34.123-1 table 6.5 for details on the ARFCN)

– inter-RAT cell id

Not present

CHOICE Radio Access Technology

GSM

– Cell individual offset

0

– Cell selection and re-selection info

Not present

– BSIC

BSIC2

– Band indicator

GSM/DCS-1800 or GSM/PCS-1900 (dependent on band used)

– BCCH ARFCN

Value according to the GSM band under test (see 3GPP 34.123-1 table 6.5 for details on the ARFCN)

– Cell for measurement

Not present

– inter-RAT measurement quantity

– Measurement quantity for UTRAN quality estimate

Not included

CHOICE system

GSM

– Measurement quantity

GSM carrier RSSI

– Filter coefficient

0

– BSIC verification required

required

– inter-RAT reporting quantity

CHOICE system

GSM

– Observed time difference to GSM cell reporting indicator

FALSE

– GSM carrier RSSI reporting indicator

TRUE

CHOICE report criteria

– Inter-RAT measurements reporting criteria

– Parameters required for each event

(1 to<maxMeasEvent>)

– Inter-RAT event identity

3d

– Threshold own system

Not present

– W

Not present

– Threshold other system

Not present

– Hysteresis

5 (2.5 dB)

– Time to Trigger

200 ms

– Reporting cell status

Report cells within active set or within virtual active set or of the other RAT

– Maximum number of reported cells

2

Physical channel information elements

– DPCH compressed mode status info

If the UE requires compressed mode (refer ICS/IXIT), this IE is present and contains the IEs as follows. If the UE does not require compressed mode (refer ICS/IXIT), this IE is not present.

– TGPS reconfiguration CFN

(Current CFN + (250 – TTI/10msec))mod 256

– Transmission gap pattern sequence (1 to <MaxTGPS>)

– TGPSI

1

– TGPS status flag

Activate

– TGCFN

(Current CFN + (252 – TTI/10msec))mod 256

– TGPSI

2

– TGPS status flag

Activate

– TGCFN

(Current CFN + (254 – TTI/10msec))mod 256

– TGPSI

3

– TGPS status flag

Activate

– TGCFN

(Current CFN + (250 – TTI/10msec))mod 256

MEASUREMENT CONTROL (Step 4)(TDD)

Information Element

Value/remark

Measurement Identity

3

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Event triggered

Additional measurements list

Not Present

CHOICE measurement type

– inter-RAT measurement

– inter-RAT measurement object list

CHOICE Inter-RAT Cell Removal

Remove all inter-RAT cells

-Remove all inter-RAT cells

(No Data)

New inter-RAT cells (1 to <MaxCellMeas>)

– inter-RAT cell id

Not present

CHOICE Radio Access Technology

GSM

– Cell individual offset

0

– Cell selection and re-selection info

Not present

– BSIC

BSIC1

– Band indicator

GSM/DCS-1800 or GSM/PCS-1900 (dependent on band used)

– BCCH ARFCN

Value according to the GSM band under test (see 3GPP 34.123-1 table 6.5 for details on the ARFCN)

– inter-RAT cell id

Not present

CHOICE Radio Access Technology

GSM

– Cell individual offset

0

– Cell selection and re-selection info

Not present

– BSIC

BSIC2

– Band indicator

GSM/DCS-1800 or GSM/PCS-1900 (dependent on band used)

– BCCH ARFCN

Value according to the GSM band under test (see 3GPP 34.123-1 table 6.5 for details on the ARFCN)

– Cell for measurement

Not present

– inter-RAT measurement quantity

– Measurement quantity for UTRAN quality estimate

Not included

CHOICE system

GSM

– Measurement quantity

GSM carrier RSSI

– Filter coefficient

0

– BSIC verification required

required

– inter-RAT reporting quantity

CHOICE system

GSM

– Observed time difference to GSM cell reporting indicator

FALSE

– GSM carrier RSSI reporting indicator

TRUE

CHOICE report criteria

– Inter-RAT measurements reporting criteria

– Parameters required for each event

(1 to<maxMeasEvent>)

– Inter-RAT event identity

3d

– Threshold own system

Not present

– W

Not present

– Threshold other system

Not present

– Hysteresis

5 (2.5 dB)

– Time to Trigger

200 ms

– Reporting cell status

Report cells within active set or within virtual active set or of the other RAT

– Maximum number of reported cells

2

MEASUREMENT REPORT (Step 5)

Information Element

Value/remark

Version

Measurement identity

Check to see if set to 3

Measured Results

– CHOICE measurement

Check to see if set to "Inter-RAT measured results list"

– Inter-RAT measured result list

– CHOICE system

GSM

– Measured GSM cells

Optional to have both Cells since a UE requiring compressed mode for inter-RAT measurements may take longer time for BSIC verification and hence need not include both the Cells

– GSM carrier RSSI

Check that measurement result is reasonable. RXLEV is mapped to a value between 0 and 63. The RSSI bits are numbered b0 to b5, where b0 is the least significant bit. When mapping the RXLEV value to the RSSI bit string, the first/ leftmost bit of the bit string contains the most significant bit.

CHOICE BSIC

Check it is set to verified BSIC

– inter-RAT cell id

Check that it is set to 0

– Observed time difference to GSM cell

Check that the IE is not included

R99 and Rel-4 only

– GSM carrier RSSI

Check that measurement result is reasonable (Optional as this can be included only if BSIC verification is completed)

CHOICE BSIC

Verified BSIC (Optional as this can be included only if BSIC verification is completed)

– inter-RAT cell id

Check that it is set to 1(Optional)

– Observed time difference to GSM cell

Check that the IE is not present (Optional)

R99 and Rel-4 only

Measured results on RACH

Check that not present

Additional Measured results

Check that not present

Event results

Check that the IE is included

– CHOICE event result

Check that this is set to inter-RAT measurement event results

– Inter-RAT event identity

Check that this is set to 3d

– Cells to report (1 to <maxCellMeas>)

Check that <maxCellMeas> is set to 1

– CHOICE BSIC

Check that this is set to verified BSIC

– Inter-RAT cell id

Check that this is set to 0.

MEASUREMENT REPORT (Step 5) (1.28 Mcps TDD)

Information Element

Value/remark

Version

Measurement identity

Check to see if set to 3

Measured Results

Check that not present

Measured results on RACH

Check that not present

Additional Measured results

Check that not present

Non Critical Extensions

– Additional Measured results – LCR

– CHOICE measurement

Check to see if set to "Inter-RAT measured results list"

– Inter-RAT measured result list

– CHOICE system

GSM

– Measured GSM cells

Optional to have both Cells since a UE requiring compressed mode for inter-RAT measurements may take longer time for BSIC verification and hence need not include both the Cells

– GSM carrier RSSI

Check that measurement result is reasonable. RXLEV is mapped to a value between 0 and 63. The RSSI bits are numbered b0 to b5, where b0 is the least significant bit. When mapping the RXLEV value to the RSSI bit string, the first/ leftmost bit of the bit string contains the most significant bit.

CHOICE BSIC

Check it is set to verified BSIC

– inter-RAT cell id

Check that it is set to 0

– Observed time difference to GSM cell

Check that the IE is not included

R99 and Rel-4 only

– GSM carrier RSSI

Check that measurement result is reasonable (Optional as this can be included only if BSIC verification is completed)

CHOICE BSIC

Verified BSIC (Optional as this can be included only if BSIC verification is completed)

– inter-RAT cell id

Check that it is set to 1(Optional)

– Observed time difference to GSM cell

Check that the IE is not present (Optional)

R99 and Rel-4 only

Event results

Check that the IE is included

– CHOICE event result

Check that this is set to inter-RAT measurement event results

– Inter-RAT event identity

Check that this is set to 3d

– Cells to report (1 to <maxCellMeas>)

Check that <maxCellMeas> is set to 1

– CHOICE BSIC

Check that this is set to verified BSIC

– Inter-RAT cell id

Check that this is set to 0.

MEASUREMENT REPORT (Step 7)

Information Element

Value/remark

Version

Measurement identity

Check to see if set to 3

Measured Results

– CHOICE measurement

Check to see if set to "Inter-RAT measured results list"

– Inter-RAT measured result list

– CHOICE system

GSM

– Measured GSM cells

Check that measurement results for two GSM cells are included

– GSM carrier RSSI

Check that measurement result is reasonable. RXLEV is mapped to a value between 0 and 63. The RSSI bits are numbered b0 to b5, where b0 is the least significant bit. When mapping the RXLEV value to the RSSI bit string, the first/ leftmost bit of the bit string contains the most significant bit.

CHOICE BSIC

Check it is set to verified BSIC

– inter-RAT cell id

Check that it is set to 1

– Observed time difference to GSM cell

Check that the IE is not included

R99 and Rel-4 only

– GSM carrier RSSI

Check that measurement result is reasonable

CHOICE BSIC

Verified BSIC

– inter-RAT cell id

Check that it is set to 0.

– Observed time difference to GSM cell

Check that the IE is not present

R99 and Rel-4 only

Measured results on RACH

Check that not present

Additional Measured results

Check that not present

Event results

Check that the IE is included

– CHOICE event result

Check that this is set to inter-RAT measurement event results

– Inter-RAT event identity

Check that this is set to 3d

– Cells to report (1 to <maxCellMeas>)

Check that <maxCellMeas> is set to 1

– CHOICE BSIC

Check that this is set to verified BSIC

– Inter-RAT cell id

Check that this is set to 1.

MEASUREMENT REPORT (Step 7) (1.28 Mcps TDD)

Information Element

Value/remark

Version

Measurement identity

Check to see if set to 3

Measured Results

Check that not present

Measured results on RACH

Check that not present

Additional Measured results

Check that not present

Non Critical Extensions

– Additional Measured results – LCR

– CHOICE measurement

Check to see if set to "Inter-RAT measured results list"

– Inter-RAT measured result list

– CHOICE system

GSM

– Measured GSM cells

Check that measurement results for two GSM cells are included

– GSM carrier RSSI

Check that measurement result is reasonable. RXLEV is mapped to a value between 0 and 63. The RSSI bits are numbered b0 to b5, where b0 is the least significant bit. When mapping the RXLEV value to the RSSI bit string, the first/ leftmost bit of the bit string contains the most significant bit.

CHOICE BSIC

Check it is set to verified BSIC

– inter-RAT cell id

Check that it is set to 1

– Observed time difference to GSM cell

Check that the IE is not included

R99 and Rel-4 only

– GSM carrier RSSI

Check that measurement result is reasonable

CHOICE BSIC

Verified BSIC

– inter-RAT cell id

Check that it is set to 0.

– Observed time difference to GSM cell

Check that the IE is not present

R99 and Rel-4 only

Event results

Check that the IE is included

– CHOICE event result

Check that this is set to inter-RAT measurement event results

– Inter-RAT event identity

Check that this is set to 3d

– Cells to report (1 to <maxCellMeas>)

Check that <maxCellMeas> is set to 1

– CHOICE BSIC

Check that this is set to verified BSIC

– Inter-RAT cell id

Check that this is set to 1.

MEASUREMENT CONTROL (Step 8)

Information Element

Value/remark

Measurement Identity

3

Measurement Command

Release

Physical channel information elements

– DPCH compressed mode status info

If the UE requires compressed mode (refer ICS/IXIT), this IE is present and contains the IEs as follows. If the UE does not require compressed mode (refer ICS/IXIT), this IE is not present.

– TGPS reconfiguration CFN

(Current CFN + (256 – TTI/10msec))mod 256

– Transmission gap pattern sequence (1 to <MaxTGPS>)

– TGPSI

1

– TGPS status flag

Deactivate

– TGCFN

Not present

– TGPSI

2

– TGPS status flag

Deactivate

– TGCFN

Not present

– TGPSI

3

– TGPS status flag

Deactivate

– TGCFN

Not present

8.4.1.36.5 Test requirement

Shortly after the UE has received the first MEASUREMENT CONTROL message it shall transmit a MEASUREMENT REPORT to the SS.

After instant T1, the UE shall begin to transmit a MEASUREMENT REPORT triggered by event 3d to the SS.

After receiving the second MEASUREMENT CONTROL message, the UE shall then stop running compressed mode.

8.4.1.37 Measurement Control and Report: UE internal measurement, event 6c

8.4.1.37.1 Definition

8.4.1.37.2 Conformance requirement

When this event is ordered by UTRAN in a measurement control message, the UE shall send a measurement report when the UE Tx power reaches its minimum value.

Reference

3GPP TS 25.331 clause 14.6.2.3.

8.4.1.37.3 Test Purpose

1. To confirm that the UE sends a measurement report for event 6c when the UE Tx power reaches its minimum value when event 6c has been configured in the UE through a MEASUREMENT CONTROL message.

8.4.1.37.4 Method of test

Initial Condition

System simulator: 1 UTRAN cell.

UE: CS-DCCH+DTCH_DCH (State 6-9) or PS-DCCH+DTCH_DCH (State 6-10) in cell 1 as specified in clause 7.4 of TS 34.108, depending on the CN domain supported by the UE.

Test procedure

The UE is initially in CELL_DCH state as specified in clause 7.4 of TS 34.108.

The SS sends a MEASUREMENT CONTROL message to the UE that configures event 6c.

For FDD and 1.28 Mcps TDD: The SS sends TPC_cmd equal to -1 until the transmitter power of the UE reaches its minimum value.

For 3.84 Mcps TDD and 7.68 Mcps TDD: The SS sets the ISCP reported for the timeslot containing the uplink DPCH to the minimum reportable value (< -120)

SS calls for generic procedure C.3 to check that UE is in CELL_DCH state.

Expected sequence

Step

Direction

Message

Comment

UE

SS

1

The UE is brought to the CELL_DCH state in the cell 1.

2

MEASUREMENT CONTROL

SS configures event 6c in the UE.

3

For FDD and 1.28 Mcps TDD: The SS sends TPC_cmd equal to -1 until the transmitter power of the UE reaches its minimum value, which shall be below –50 dBm.

3a

For 3.84 Mcps TDD and 7.68 Mcps: The SS sets the ISCP reported for the timeslot containing the uplink DPCH to the minimum reportable value (< -120)

4

MEASUREMENT REPORT

After about 10 ms, the UE sends a MEASUREMENT REPORT to SS triggered by event 6c.

5



CALL C.3

If the test result of C.3 indicates that UE is in CELL_DCH state, the test passes, otherwise it fails.

Specific message content

MEASUREMENT CONTROL (Step 2) (FDD)

Information Element

Value/remark

Measurement Identity

6

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Event triggered

Additional measurements list

Not Present

CHOICE measurement type

– UE internal measurement

– UE internal measurement quantity

UE Transmitter Power

– Filter coefficient

0

– UE internal reporting quantity

– UE Transmitted power

TRUE

CHOICE mode

– UE Rx-Tx time difference

FALSE

CHOICE report criteria

– UE internal measurement reporting criteria

– Parameters sent for each UE internal measurement event

1 event

– UE internal event identity

event 6c

– Time to trigger

10

MEASUREMENT CONTROL (Step 2)( 1.28 Mcps TDD)

Information Element

Value/remark

Measurement Identity

6

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Event trigger

Additional measurements list

Not Present

CHOICE measurement type

UE internal measurement

– CHOICE mode

TDD

– measurement quantity

UE Transmitter Power

– Filter coefficient

0

– UE internal reporting quantity

– UE Transmitted power

TRUE

– CHOICE mode

TDD

– CHOICE TDD option

1.28 Mcps TDD

– TADV info

FALSE

– CHOICE report criteria

UE internal measurement reporting criteria

– Parameters sent for each UE internal measurement event

– UE internal event identity

6c

– Time to trigger

0

MEASUREMENT CONTROL (Step 2) (3.84 Mcps TDD)

Information Element

Value/remark

Measurement Identity

6

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Event trigger

Additional measurements list

Not Present

CHOICE measurement type

UE internal measurement

– CHOICE mode

TDD

– measurement quantity

UE Transmitter Power

– Filter coefficient

0

– UE internal reporting quantity

– UE Transmitted power

TRUE

– CHOICE mode

TDD

– CHOICE TDD option

3.84 Mcps TDD

– Applied TA

FALSE

– CHOICE report criteria

UE internal measurement reporting criteria

– Parameters sent for each UE internal measurement event

– UE internal event identity

6c

– Time to trigger

0

MEASUREMENT CONTROL (Step 2) (7.68 Mcps TDD)

Information Element

Value/remark

Measurement Identity

6

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Event trigger

Additional measurements list

Not Present

CHOICE measurement type

UE internal measurement

– CHOICE mode

TDD

– measurement quantity

UE Transmitter Power

– Filter coefficient

0

– UE internal reporting quantity

– UE Transmitted power

TRUE

– CHOICE mode

TDD

– CHOICE TDD option

7.68 Mcps TDD

– Applied TA

FALSE

– CHOICE report criteria

UE internal measurement reporting criteria

– Parameters sent for each UE internal measurement event

– UE internal event identity

6c

– Time to trigger

0

MEASUREMENT REPORT (Step 4) (FDD)

Information Element

Value/remark

Measurement identity

Check to see if set to 6

Measured Results

– CHOICE measurement

Check to see if set to "UE internal measurement"

– UE internal measured results

– UE Transmitted Power

Check that this IE is set a value that is equal to –50 dBm.

– UE Rx-Tx report entities

Check that this IE is not included

Measured results on RACH

Check that this IE is not included

Additional measured results

Check that this IE is not included

Event Results

CHOICE event result

Check that this IE is set to UE internal measurement event results

UE internal measurement results

UE internal event identity

Check that this IE is set to 6c

CHOICE mode

Primary CPICH info

This IE should not be included

MEASUREMENT REPORT (Step 4) (1.28 Mcps TDD)

Information Element

Value/remark

Measurement identity

Check to see if set to 6

Measured Results

– CHOICE measurement

Check to see if set to "UE internal measured results "

-CHOICE mode

Check to see if set to TDD

– UE Transmitted Power

Check that this IE is set a value that is below –49 dBm.

– CHOICE TDD option

Check to see if set to”1.28 Mcps TDD”

– TADV

Check that this IE is not included

Measured results on RACH

Check that this IE is not included

Additional measured results

Check that this IE is not included

Event Results

CHOICE event result

Check that this IE is set to UE internal measurement event results

UE internal measurement results

UE internal event identity

Check that this IE is set to 6c

MEASUREMENT REPORT (Step 4) (3.84 Mcps TDD)

Information Element

Value/remark

Measurement identity

Check to see if set to 6

Measured Results

– CHOICE measurement

Check to see if set to "UE internal measured results "

-CHOICE mode

Check to see if set to TDD

– UE Transmitted Power

Check that this IE is set a value that is below –45 dBm.

– CHOICE TDD option

Check to see if set to”3.84 Mcps TDD”

– Applied TA

Check that this IE is not included

Measured results on RACH

Check that this IE is not included

Additional measured results

Check that this IE is not included

Event Results

CHOICE event result

Check that this IE is set to UE internal measurement event results

UE internal measurement results

UE internal event identity

Check that this IE is set to 6c

MEASUREMENT REPORT (Step 4) (7.68 Mcps TDD)

Information Element

Value/remark

Measurement identity

Check to see if set to 6

Measured Results

– CHOICE measurement

Check to see if set to "UE internal measured results "

-CHOICE mode

Check to see if set to TDD

– UE Transmitted Power

Check that this IE is set a value that is below –45 dBm.

– CHOICE TDD option

Check to see if set to”7.68 Mcps TDD”

– Applied TA

Check that this IE is not included

Measured results on RACH

Check that this IE is not included

Additional measured results

Check that this IE is not included

Event Results

CHOICE event result

Check that this IE is set to UE internal measurement event results

UE internal measurement results

UE internal event identity

Check that this IE is set to 6c

8.4.1.37.5 Test requirement

The UE shall then begin transmitting a MEASUREMENT REPORT message to SS triggered by event 6c when its transmit power has reached its minimum output power. The minimum transmitted power of the UE shall be less than –50dBm.(for FDD), -49dBm (for 1.28 Mcps TDD), and -45dBm (for 3.84 Mcps TDD and 7.68 Mcps TDD)

8.4.1.38 Measurement Control and Report: UE internal measurement, event 6d

8.4.1.38.1 Definition

8.4.1.38.2 Conformance requirement

When this event is ordered by UTRAN in a measurement control message, the UE shall send a measurement report when the UE Tx power reaches its maximum value.

Reference

3GPP TS 25.331 clause 14.6.2.4

8.4.1.38.3 Test Purpose

1. To confirm that the UE sends a measurement report for event 6d when the UE Tx power reaches its maximum value when event 6d has been configured in the UE through a MEASUREMENT CONTROL message.

8.4.1.38.4 Method of test

Initial Condition

System simulator: 1 UTRAN cell.

UE: CS-DCCH+DTCH_DCH (State 6-9) or PS-DCCH+DTCH_DCH (State 6-10) in cell 1 as specified in clause 7.4 of TS 34.108, depending on the CN domain supported by the UE.

Test procedure

The UE is initially in CELL_DCH state as specified in clause 7.4 of TS 34.108.

For FDD and 1.28 Mcps TDD: The SS sends TPC_cmd equal to +1 until the transmitter power of the UE reaches its maximum value.

For 3.84 Mcps TDD and 7.68 Mcps TDD: The SS sets the ISCP reported for the timeslot containing the uplink DPCH to the maximum reportable.

SS calls for generic procedure C.3 to check that UE is in CELL_DCH state.

Expected sequence

Step

Direction

Message

Comment

UE

SS

1

The UE is brought to the CELL_DCH state in the cell 1.

2

MEASUREMENT CONTROL

SS configures event 6d in the UE.

3

For FDD and 1.28 Mcps TDD: The SS sends TPC_cmd equal to +1 until the transmitter power of the UE reaches its maximum value.

3a

For 3.84 Mcps TDD and 7.68 Mcps TDD: The SS sets the ISCP reported for the timeslot containing the uplink DPCH to the maximum reportable.

4

MEASUREMENT REPORT

After about 200 ms, the UE sends a MEASUREMENT REPORT to SS triggered by event 6d.

5



CALL C.3

If the test result of C.3 indicates that UE is in CELL_DCH state, the test passes, otherwise it fails.

MEASUREMENT CONTROL (Step 2) (FDD)

Information Element

Value/remark

Measurement Identity

6

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Event triggered

Additional measurements list

Not Present

CHOICE measurement type

– UE internal measurement

– UE internal measurement quantity

UE Transmitter Power

– Filter coefficient

0

– UE internal reporting quantity

– UE Transmitted power

TRUE

– CHOICE mode

– UE Rx-Tx time difference

FALSE

CHOICE report criteria

– UE internal measurement reporting criteria

– Parameters sent for each UE internal measurement event

1 event

– UE internal event identity

event 6d

– Time to trigger

200

MEASUREMENT CONTROL (Step 2)( 1.28 Mcps TDD)

Information Element

Value/remark

Measurement Identity

6

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Event triggered

Additional measurements list

Not Present

CHOICE measurement type

UE internal measurement

– CHOICE mode

TDD

– measurement quantity

UE Transmitter Power

– Filter coefficient

0

– UE internal reporting quantity

– UE Transmitted power

TRUE

– CHOICE mode

TDD

– CHOICE TDD option

1.28 Mcps TDD

– TADV info

FALSE

– CHOICE report criteria

UE internal measurement reporting criteria

– Parameters sent for each UE internal measurement event

– UE internal event identity

6d

– Time to trigger

200

MEASUREMENT CONTROL (Step 2) (3.84 Mcps TDD)

Information Element

Value/remark

Measurement Identity

6

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Event triggered

Additional measurements list

Not Present

CHOICE measurement type

UE internal measurement

– CHOICE mode

TDD

– measurement quantity

UE Transmitter Power

– Filter coefficient

0

– UE internal reporting quantity

– UE Transmitted power

TRUE

– CHOICE mode

TDD

– CHOICE TDD option

3.84 Mcps TDD

– Applied TA

FALSE

– CHOICE report criteria

UE internal measurement reporting criteria

– Parameters sent for each UE internal measurement event

– UE internal event identity

6d

– Time to trigger

200

MEASUREMENT CONTROL (Step 2) (7.68 Mcps TDD)

Information Element

Value/remark

Measurement Identity

6

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Event triggered

Additional measurements list

Not Present

CHOICE measurement type

UE internal measurement

– CHOICE mode

TDD

– measurement quantity

UE Transmitter Power

– Filter coefficient

0

– UE internal reporting quantity

– UE Transmitted power

TRUE

– CHOICE mode

TDD

– CHOICE TDD option

7.68 Mcps TDD

– Applied TA

FALSE

– CHOICE report criteria

UE internal measurement reporting criteria

– Parameters sent for each UE internal measurement event

– UE internal event identity

6d

– Time to trigger

200

MEASUREMENT REPORT (Step 4) (FDD)

Information Element

Value/remark

Measurement identity

Check to see if set to 6

Measured Results

– CHOICE measurement

Check to see if set to "UE internal measurement"

– UE internal measured results

– UE Transmitted Power

Check that this IE is set to the maximum out power of the UE.

– UE Rx-Tx report entities

Check that this IE is not included

Measured results on RACH

Check that this IE is not included

Additional measured results

Check that this IE is not included

Event Results

CHOICE event result

Check that this IE is set to UE internal measurement event results

UE internal measurement results

UE internal event identity

Check that this IE is set to 6d

CHOICE mode

Primary CPICH info

This IE should not be included

MEASUREMENT REPORT (Step 4)(1.28 Mcps TDD)

Information Element

Value/remark

Measurement identity

Check to see if set to 6

Measured Results

– CHOICE measurement

Check to see if set to "UE internal measured results "

– CHOICE mode

Check to see if set to TDD

– UE Transmitted Power

Check that this IE is set to the maximum out power of the UE.

– CHOICE TDD option

Check to see if set to “1.28 Mcps TDD”

– TADV

Check that this IE is not included

Measured results on RACH

Check that this IE is not included

Additional measured results

Check that this IE is not included

Event Results

CHOICE event result

Check that this IE is set to UE internal measurement event results

UE internal event identity

Check that this IE is set to 6d

MEASUREMENT REPORT (Step 4) (3.84 Mcps TDD)

Information Element

Value/remark

Measurement identity

Check to see if set to 6

Measured Results

– CHOICE measurement

Check to see if set to "UE internal measured results "

– CHOICE mode

Check to see if set to TDD

– UE Transmitted Power

Check that this IE is set to the maximum out power of the UE.

– CHOICE TDD option

Check to see if set to “3.84 Mcps TDD”

– Applied TA

Check that this IE is not included

Measured results on RACH

Check that this IE is not included

Additional measured results

Check that this IE is not included

Event Results

CHOICE event result

Check that this IE is set to UE internal measurement event results

UE internal event identity

Check that this IE is set to 6d

MEASUREMENT REPORT (Step 4) (7.68 Mcps TDD)

Information Element

Value/remark

Measurement identity

Check to see if set to 6

Measured Results

– CHOICE measurement

Check to see if set to "UE internal measured results "

– CHOICE mode

Check to see if set to TDD

– UE Transmitted Power

Check that this IE is set to the maximum out power of the UE.

– CHOICE TDD option

Check to see if set to “7.68 Mcps TDD”

– Applied TA

Check that this IE is not included

Measured results on RACH

Check that this IE is not included

Additional measured results

Check that this IE is not included

Event Results

CHOICE event result

Check that this IE is set to UE internal measurement event results

UE internal event identity

Check that this IE is set to 6d

8.4.1.38.5 Test requirement

The UE shall then begin transmitting a MEASUREMENT REPORT message to SS triggered by event 6d when its transmit power has reached its maximum. The maximum transmitted power of the UE shall be according to the class of the UE.

8.4.1.39 Measurement Control and Report: UE internal measurement, event 6e

8.4.1.39.1 Definition

8.4.1.39.2 Conformance requirement

When this event is ordered by UTRAN in a measurement control message, the UE shall send a measurement report when the UE RSSI reaches the UE’s dynamic receiver range.

Reference

3GPP TS 25.331 clause 14.6.2.5

8.4.1.39.3 Test Purpose

1. To confirm that the UE sends a measurement report for event 6e when the UE RSSI reaches the UE’s dynamic receiver range when event 6e has been configured in the UE through a MEASUREMENT CONTROL message.

8.4.1.39.4 Method of test

Initial Condition

System simulator: 1 UTRAN cell.

UE: CS-DCCH+DTCH_DCH (State 6-9) or PS-DCCH+DTCH_DCH (State 6-10) in cell 1 as specified in clause 7.4 of TS 34.108, depending on the CN domain supported by the UE.

Test procedure

The UE is initially in CELL_DCH state as specified in clause 7.4 of TS 34.108.

The SS increases its output power by 1dB step until the UE RSSI reaches the UE’s receiver dynamic range. SS calls for generic procedure C.3 to check that UE is in CELL_DCH state.

Expected sequence

Step

Direction

Message

Comment

UE

SS

1

The UE is brought to the CELL_DCH state in the cell 1.

2

MEASUREMENT CONTROL

SS configures event 6e in the UE.

3

The SS increases its output power by 1 dB steps until the UE RSSI reaches the UE’s receiver dynamic range.

4

MEASUREMENT REPORT

The UE sends a MEASUREMENT REPORT to SS triggered by event 6e.

5



CALL C.3

If the test result of C.3 indicates that UE is in CELL_DCH state, the test passes, otherwise it fails.

MEASUREMENT CONTROL (Step 2) (FDD)

Information Element

Value/remark

Measurement Identity

6

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Event triggered

Additional measurements list

Not Present

CHOICE measurement type

– UE internal measurement

– UE internal measurement quantity

UTRA Carrier RSSI

– Filter coefficient

0

– UE internal reporting quantity

– UE Transmitted Power

TRUE

– CHOICE mode

FDD

– UE Rx-Tx time difference

FALSE

CHOICE report criteria

– UE internal measurement reporting criteria

– Parameters sent for each UE internal measurement event

1 event

– UE internal event identity

event 6e

– Time to trigger

0

MEASUREMENT CONTROL (Step 2) (1.28 Mcps TDD)

Information Element

Value/remark

Measurement Identity

6

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Event triggered

Additional measurements list

Not Present

CHOICE measurement type

UE internal measurement

– UE internal measurement quantity

– CHOICE mode

TDD

– measurement quantity

UTRA Carrier RSSI

– Filter coefficient

0

– UE internal reporting quantity

– UE Transmitted Power

False

– CHOICE mode

TDD

– CHOICE TDD option

1.28 Mcps TDD

– TADV info

False

CHOICE report criteria

UE internal measurement reporting criteria

– Parameters sent for each UE internal measurement event

– UE internal event identity

6e

– Time to trigger

0

MEASUREMENT CONTROL (Step 2) (3.84 Mcps TDD)

Information Element

Value/remark

Measurement Identity

6

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Event triggered

Additional measurements list

Not Present

CHOICE measurement type

UE internal measurement

– UE internal measurement quantity

– CHOICE mode

TDD

– measurement quantity

UTRA Carrier RSSI

– Filter coefficient

0

– UE internal reporting quantity

– UE Transmitted Power

False

– CHOICE mode

TDD

– CHOICE TDD option

3.84 Mcps TDD

– Tadvance

False

CHOICE report criteria

UE internal measurement reporting criteria

– Parameters sent for each UE internal measurement event

– UE internal event identity

6e

– Time to trigger

0

MEASUREMENT CONTROL (Step 2) (7.68 Mcps TDD)

Information Element

Value/remark

Measurement Identity

6

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Event triggered

Additional measurements list

Not Present

CHOICE measurement type

UE internal measurement

– UE internal measurement quantity

– CHOICE mode

TDD

– measurement quantity

UTRA Carrier RSSI

– Filter coefficient

0

– UE internal reporting quantity

– UE Transmitted Power

False

– CHOICE mode

TDD

– CHOICE TDD option

7.68 Mcps TDD

– Tadvance

False

CHOICE report criteria

UE internal measurement reporting criteria

– Parameters sent for each UE internal measurement event

– UE internal event identity

6e

– Time to trigger

0

MEASUREMENT REPORT (Step 4) (FDD)

Information Element

Value/remark

Measurement identity

Check to see if set to 6

Measured Results

– CHOICE measurement

UE internal measured results

– CHOICE mode

FDD

– UE transmitted power

Check that this value is within reasonable range of value.

– UE Rx-TX report entries

Check that this IE is not included

Measured results on RACH

Check that this IE is not included

Additional measured results

Check that this IE is not included

Event Results

CHOICE event result

Check that this IE is set to UE internal measurement event results

UE internal measurement results

UE internal event identity

Check that this IE is set to 6e

CHOICE mode

Primary CPICH info

This IE should not be included

MEASUREMENT REPORT (Step 4) (TDD)

Information Element

Value/remark

Measurement identity

Check to see if set to 6

Measured Results

Check that this IE is not included

Measured results on RACH

Check that this IE is not included

Additional measured results

Check that this IE is not included

Event Results

CHOICE event result

Check that this IE is set to UE internal measurement event results

UE internal event identity

Check that this IE is set to 6e

8.4.1.39.5 Test requirement

The UE shall then begin transmitting a MEASUREMENT REPORT message to SS triggered by event 6e when the UE RSSI reaches the UE’s receiver dynamic range.

8.4.1.40 Measurement Control and Report: Inter-RAT measurement, event 3C, in CELL_DCH state using sparse compressed mode pattern

8.4.1.40.1 Definition

8.4.1.40.2 Conformance requirement

1. Upon reception of a MEASUREMENT CONTROL message the UE shall perform actions specified in 3GPP TS 25.331 clause 8.6 unless otherwise specified below.

The UE shall:

– read the IE "Measurement command";

– if the IE "measurement command" has the value "setup":

– store this measurement in the variable MEASUREMENT_IDENTITY according to the IE "measurement identity", possibly overwriting the measurement previously stored with that identity;

– for measurement types "inter-RAT measurement" or "inter-frequency measurement":

– if, according to its measurement capabilities, the UE requires compressed mode to perform the measurements and a compressed mode pattern sequence with an appropriate measurement purpose is simultaneously activated by the IE "DPCH compressed mode status info"; or

– if, according to its measurement capabilities, the UE does not require compressed mode to perform the measurements:

– begin measurements according to the stored control information for this measurement identity;

2. Event 3c: The estimated quality of other system is above a certain threshold. When this event is ordered by UTRAN in a measurement control message the UE shall send a report when the estimated quality of the other system is above the value of the IE "Threshold other system" and the hysteresis and time to trigger conditions are fulfilled. The corresponding report contains information specific for the other system.

Reference

3GPP TS 25.331 clause 8.4.1.3, 14.3.1.3.

8.4.1.40.3 Test Purpose

This test case is only applicable to UEs supporting both FDD and GSM, and which require compressed mode to perform the GSM related measurements.

1. To verify that the UE performs Inter-RAT measurement using a sparse compressed mode pattern as specified in the MEASUREMENT CONTROL message.

  1. To verify that the UE send MEASUREMENT REPORT message when event 3C is triggered, and if the quality of the other system becomes better than the given threshold for event 3c.

3. To confirm that no other UE MEASUREMENT REPORT message is sent by the UE for a cell that has already triggered event 3c as long as the hysteresis condition for triggering once again event 3c has not been fulfilled.

8.4.1.40.4 Method of test

Table 8.4.1.40.4-1 Sparse compressed mode pattern for Inter RAT measurement

TGMP

TGCFN

TGPRC

TGSN

TGL1

TGL2

TGD

TGPL1

TGPL2

Comment

GSM carrier RSSI measurement

Note 1

Inf.

4

7

Not sent

undefined

16

See note 2

Set-up to monitor 12 GSM neighbours every second measurement period, i.e. every second 480ms period.

GSM Initial BSIC identification

Note 1

Inf.

8

14

Not sent

undefined

24

See note 2

Equal to Pattern 6 in TS 25.133 table 8.7.

GSM BSIC re-confirmation

Note 1

Inf.

8

14

Not sent

undefined

24

See note 2

Equal to Pattern 12 in TS 25.133 table 8.8.

NOTE 1: TGCFN can be found in the MEASUREMENT CONTROL message.

NOTE 2: For R99 and Rel-4: TGPL2 is not sent. For Rel-5 and later releases: Not applicable.

Initial Condition

System simulator: 1 UTRAN FDD cell and 2 GSM cells. The initial configurations of the cells in the SS shall follow the values indicated in the column marked T0 in table 8.4.1.40-2. The UTRAN FDD cell shall use UARFCN according to the band under test except in the case of where FDD band VIII is tested and GSM900 is used for the Inter-RAT cells, then “High Range” test frequency for Band VIII is used instead, to avoid the test channels overlapping.

UE: CS-DCCH+DTCH_DCH (State 6-9) or PS-DCCH+DTCH_DCH (State 6-10) in cell 1 (UTRA) as specified in clause 7.4 of TS 34.108, depending on the CN domain supported by the UE.

Related ICS/IXIT statements

– UE supports GSM-P, GSM-E, GSM-DCS, GSM-450, GSM-480, GSM-PCS, GSM-850.

Test procedure

Table 8.4.1.40.4-2 Inter-RAT cell specific data

Parameter

Unit

Cell 1 (GSM)

Cell 2 (GSM)

T0

T1

T2

T3

T0

T1

T2

T3

Test Channel

#

GSM Ch.1

GSM Ch.2

BCCH ARFCN

#

Value according to the GSM band under test (see 3GPP 34.123-1 table 6.5 for details on the ARFCN)

Value according to the GSM band under test (see 3GPP 34.123-1 table 6.5 for details on the ARFCN)

CELL identity

#

0

1

BSIC

#

BSIC 1

BSIC 2

RF Signal Level

dBm

-90

-75

-80

-75

-75

-75

-75

-75

GSM cell 3 to 12 as indicated in the a MEASUREMENT CONTROL message shall not be active in the test, i.e. no BCCH carrier shall be transmitted for GSM cell 3 to 12 in this test.

The table above illustrate the downlink power to be applied for the two cells at various instants of the test execution. Column marked "T0" denotes the initial conditions, while column marked "T1", "T2" and "T3" indicate the values to be applied subsequently.

The UE is initially in CELL_DCH state as specified in clause 7.4 of TS 34.108. UTRA cell 1 is the only cell in the active set of the UE. The SS sends a PHYSICAL CHANNEL RECONFIGURATION message to the UE to configure the compressed mode pattern sequence parameters to the UE. Three compressed mode patterns are configured, according to the message specified below. When the PHYSICAL CHANNEL RECONFIGURATION COMPLETE is received from the UE, the SS sends a MEASUREMENT CONTROL message to the UE, to set up inter-RAT measurements on 12 GSM cells. Event 3c is set up in this message, and compressed mode is activated.

At instant T1, the RF signal strength for GSM cell 1 increases as described in table 8.4.1.40.4-2, since the cell individual offset for GSM cell 1 is 10 dB, event 3c shall be triggered in the UE. A MEASUREMENT REPORT shall be sent to the SS. Note that GSM cell 2 has not triggered event 3c even though the RF signal strength for GSM cell 2 is the same as for cell 1, because the cell individual offset for GSM cell 2 is -3 dB.

At instant T2, the RF signal strength for GSM cell 1 drops as described in table 8.4.1.40.4-2, and at instant T3, it increases again to its previous level. No MEASUREMENT REPORT shall be received from the UE, since GSM cell 1 has already triggered event 3c, and since the RF signal strength has not dropped enough for the leaving condition to be met. SS calls for generic procedure C.3 to check that UE is in CELL_DCH state.

Expected Sequence

Step

Direction

Message

Comment

UE

SS

1

The UE is brought to the CELL_DCH state in the cell 1.

2

PHYSICAL CHANNEL RECONFIGURATION

Compressed mode pattern sequence parameters are loaded to UE.

3

PHYSICAL CHANNEL RECONFIGURATION COMPLETE

4

MEASUREMENT CONTROL

SS configures event 3c in the UE, compressed mode is started.

5

SS waits for approximately 10 seconds and verifies that no MEASUREMENT REPORT messages are detected on uplink DCCH.

6

SS re-adjusts the downlink transmission power settings according to columns "T1" in table 8.4.1.40.4-2.

7

MEASUREMENT REPORT

After about 1.6 s, the UE sends a MEASUREMENT REPORT to SS triggered by event 3c.

8

SS re-adjusts the downlink transmission power settings according to columns "T2" in table 8.4.1.40.4-2.

9

SS re-adjusts the downlink transmission power settings according to columns "T3" in table 8.4.1.40.4-2.

10

SS waits for approximately 10 seconds and verifies that no MEASUREMENT REPORT messages are detected on uplink DCCH.

11



CALL C.3

If the test result of C.3 indicates that UE is in CELL_DCH state, the test passes, otherwise it fails.

Specific Message Content

PHYSICAL CHANNEL RECONFIGURATION (Step 2)

Use the same message sub-type in clause 9 of TS 34.108 titled "Non speech in CS" or "Speech in CS" or "Packet to CELL_DCH from CELL_DCH in PS, with Scrambling code change set to Default1 and with the following exceptions:

Information Element

Value/remark

Version

Downlink information common for all radio links

– DPCH compressed mode info

– TGPSI

1

– TGPS Status Flag

Deactivate

– TGCFN

Not present

– Transmission gap pattern sequence configuration parameters

– TGMP

GSM Carrier RSSI Measurement

– TGPRC

Infinity

– TGSN

4

– TGL1

7

– TGL2

Not present

– TGD

undefined

– TGPL1

16

– TGPL2

Not present

R99 and REL-4 only

– RPP

Mode 0

– ITP

Mode 0

CHOICE UL/DL Mode

UL&DL or UL-only or DL-only (depends on UE’s Measurement capability)

– Downlink compressed mode method

SF/2

– Uplink compressed mode method

SF/2

– Downlink frame type

A

– DeltaSIR1

10 (1.0)

– DeltaSIRAfter1

5 (0.5)

– DeltaSIR2

Not Present

– DeltaSIR2After2

Not Present

– N identify abort

Not Present

– T Reconfirm abort

Not Present

– TGPSI

2

– TGPS Status Flag

Deactivate

– TGCFN

Not present

– Transmission gap pattern sequence configuration parameters

– TGMP

GSM BSIC identification

– TGPRC

Infinity

– TGSN

8

– TGL1

14

– TGL2

Not present

– TGD

undefined

– TGPL1

24

– TGPL2

Not present

R99 and REL-4 only

– RPP

Mode 0

– ITP

Mode 0

CHOICE UL/DL Mode

UL&DL or UL-only or DL-only (depends on UE’s Measurement capability)

– Downlink compressed mode method

SF/2

– Uplink compressed mode method

SF/2

– Downlink frame type

A

– DeltaSIR1

10 (1.0)

– DeltaSIRAfter1

5 (0.5)

– DeltaSIR2

Not Present

– DeltaSIR2After2

Not Present

– N identify abort

66

– T Reconfirm abort

Not Present

– TGPSI

3

– TGPS Status Flag

Deactivate

– TGCFN

Not present

– Transmission gap pattern sequence configuration parameters

– TGMP

GSM BSIC re-confirmation

– TGPRC

Infinity

– TGSN

8

– TGL1

14

– TGL2

Not present

– TGD

undefined

– TGPL1

24

– TGPL2

Not present

R99 and REL-4 only

– RPP

Mode 0

– ITP

Mode 0

CHOICE UL/DL Mode

UL&DL or UL-only or DL-only (depends on UE’s Measurement capability)

– Downlink compressed mode method

SF/2

– Uplink compressed mode method

SF/2

– Downlink frame type

A

– DeltaSIR1

10 (1.0)

– DeltaSIRAfter1

5 (0.5)

– DeltaSIR2

Not Present

– DeltaSIR2After2

Not Present

– N identify abort

Not Present

– T Reconfirm abort

10 (5 s)

Downlink information per radio link list

– Choice mode

FDD

– Primary CPICH info

– Primary scrambling code

Ref. to the Default setting in clause 6.1 (FDD)

– PDSCH with SHO DCH info

Not Present

R99 and Rel-4 only

– PDSCH code mapping

Not Present

R99 and Rel-4 only

– Serving HS-DSCH radio link indicator

FALSE

Rel-5

– Serving E-DCH radio link indicator

FALSE

Rel-6

– Downlink DPCH info for each RL

– CHOICE mode

FDD

– Primary CPICH usage for channel estimation

Primary CPICH may be used

– DPCH frame offset

Set to value : Default DPCH Offset Value (as currently stored in SS) mod 38 400

– Secondary CPICH info

Not Present

– DL channelisation code

– Secondary scrambling code

5

– Spreading factor

Reference to clause 6.10 Parameter Set

– Code number

0

– Scrambling code change

Set to value Default1: No code change (if the UE has a compressed mode pattern sequence configured in variable TGPS_IDENTITY or included in the message including IE "Downlink DPCH info for each RL", which is using compressed mode method "SF/2")

– TPC combination index

0

– SSDT Cell Identity

Not Present

R99 and Rel-4 only

– Closed loop timing adjustment mode

Not Present

– E-AGCH Info

Not Present

Rel-6

– E-HICH Information

Not Present

Rel-6

– E-RGCH Information

Not Present

Rel-6

– SCCPCH information for FACH

Not Present

R99 and Rel-4 only

MEASUREMENT CONTROL (Step 4)

Information Element

Value/remark

Measurement Identity

3

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Event triggered

Additional measurements list

Not Present

CHOICE measurement type

– inter-RAT measurement

– inter-RAT measurement object list

CHOICE Inter-RAT Cell Removal

Remove all inter-RAT cells

-Remove all inter-RAT cells

(No Data)

New inter-RAT cells (1 to <MaxCellMeas>)

– inter-RAT cell id

0

CHOICE Radio Access Technology

GSM

– Cell individual offset

10

– Cell selection and re-selection info

Not present

– BSIC

BSIC1

– Band indicator

GSM/DCS-1800 or GSM/PCS-1900 (dependent on band used)

– BCCH ARFCN

Value according to the GSM band under test (see 3GPP 34.123-1 table 6.5 for details on the ARFCN)

– inter-RAT cell id

1

CHOICE Radio Access Technology

GSM

– Cell individual offset

-3

– Cell selection and re-selection info

Not present

– BSIC

BSIC2

– Band indicator

GSM/DCS-1800 or GSM/PCS-1900 (dependent on band used)

– BCCH ARFCN

Value according to the GSM band under test (see 3GPP 34.123-1 table 6.5 for details on the ARFCN)

– inter-RAT cell id

2

CHOICE Radio Access Technology

GSM

– Cell individual offset

0

– Cell selection and re-selection info

Not present

– BSIC

BSIC3

– Band indicator

GSM/DCS-1800 or GSM/PCS-1900 (dependent on band used)

– BCCH ARFCN

Value according to the GSM band under test (see 3GPP 34.123-1 table 6.5 for details on the ARFCN)

– inter-RAT cell id

3

CHOICE Radio Access Technology

GSM

– Cell individual offset

0

– Cell selection and re-selection info

Not present

– BSIC

BSIC4

– Band indicator

GSM/DCS-1800 or GSM/PCS-1900 (dependent on band used)

– BCCH ARFCN

Value according to the GSM band under test (see 3GPP 34.123-1 table 6.5 for details on the ARFCN)

– inter-RAT cell id

4

CHOICE Radio Access Technology

GSM

– Cell individual offset

0

– Cell selection and re-selection info

Not present

– BSIC

BSIC5

– Band indicator

GSM/DCS-1800 or GSM/PCS-1900 (dependent on band used)

– BCCH ARFCN

Value according to the GSM band under test (see 3GPP 34.123-1 table 6.5 for details on the ARFCN)

– inter-RAT cell id

5

CHOICE Radio Access Technology

GSM

– Cell individual offset

0

– Cell selection and re-selection info

Not present

– BSIC

BSIC6

– Band indicator

GSM/DCS-1800 or GSM/PCS-1900 (dependent on band used)

– BCCH ARFCN

Value according to the GSM band under test (see 3GPP 34.123-1 table 6.5 for details on the ARFCN)

– inter-RAT cell id

6

CHOICE Radio Access Technology

GSM

– Cell individual offset

0

– Cell selection and re-selection info

Not present

– BSIC

BSIC7

– Band indicator

GSM/DCS-1800 or GSM/PCS-1900 (dependent on band used)

– BCCH ARFCN

Value according to the GSM band under test (see 3GPP 34.123-1 table 6.5 for details on the ARFCN)

– inter-RAT cell id

7

CHOICE Radio Access Technology

GSM

– Cell individual offset

0

– Cell selection and re-selection info

Not present

– BSIC

BSIC8

– Band indicator

GSM/DCS-1800 or GSM/PCS-1900 (dependent on band used)

– BCCH ARFCN

Value according to the GSM band under test (see 3GPP 34.123-1 table 6.5 for details on the ARFCN)

– inter-RAT cell id

8

CHOICE Radio Access Technology

GSM

– Cell individual offset

0

– Cell selection and re-selection info

Not present

– BSIC

BSIC9

– Band indicator

GSM/DCS-1800 or GSM/PCS-1900 (dependent on band used)

– BCCH ARFCN

Value according to the GSM band under test (see 3GPP 34.123-1 table 6.5 for details on the ARFCN)

– inter-RAT cell id

9

CHOICE Radio Access Technology

GSM

– Cell individual offset

0

– Cell selection and re-selection info

Not present

– BSIC

BSIC10

– Band indicator

GSM/DCS-1800 or GSM/PCS-1900 (dependent on band used)

– BCCH ARFCN

Value according to the GSM band under test (see 3GPP 34.123-1 table 6.5 for details on the ARFCN)

– inter-RAT cell id

10

CHOICE Radio Access Technology

GSM

– Cell individual offset

0

– Cell selection and re-selection info

Not present

– BSIC

BSIC11

– Band indicator

GSM/DCS-1800 or GSM/PCS-1900 (dependent on band used)

– BCCH ARFCN

Value according to the GSM band under test (see 3GPP 34.123-1 table 6.5 for details on the ARFCN)

– inter-RAT cell id

11

CHOICE Radio Access Technology

GSM

– Cell individual offset

0

– Cell selection and re-selection info

Not present

– BSIC

BSIC12

– Band indicator

GSM/DCS-1800 or GSM/PCS-1900 (dependent on band used)

– BCCH ARFCN

Value according to the GSM band under test (see 3GPP 34.123-1 table 6.5 for details on the ARFCN)

– Cell for measurement

Not present

– inter-RAT measurement quantity

– Measurement quantity for UTRAN quality estimate

Not included

CHOICE system

GSM

– Measurement quantity

GSM carrier RSSI

– Filter coefficient

0

– BSIC verification required

required

– inter-RAT reporting quantity

CHOICE system

GSM

– Observed time difference to GSM

FALSE

cell reporting indicator

– GSM carrier RSSI reporting indicator

TRUE

CHOICE report criteria

– Inter-RAT measurements reporting criteria

– Parameters required for each event

(1 to<maxMeasEvent>)

– Inter-RAT event identity

3c

– Threshold own system

Not included

– W

Not included

– Threshold other system

-74

– Hysteresis

5 (2.5 dB)

– Time to Trigger

100 ms

– Reporting cell status

Report cells within active set or within virtual active set or of the other RAT

– Maximum number of reported cells

2

Physical channel information elements

– DPCH compressed mode status info

– TGPS reconfiguration CFN

(Current CFN + (256 – 11 – TTI/10msec))mod 256

– Transmission gap pattern sequence (1 to <MaxTGPS>)

– TGPSI

1

– TGPS status flag

Activate

– TGCFN

(Current CFN + (256 – 11 – TTI/10msec)) mod 256

– TGPSI

2

– TGPS status flag

Activate

– TGCFN

(Current CFN + (256 – 7 – TTI/10msec)) mod 256

– TGPSI

3

– TGPS status flag

Activate

– TGCFN

(Current CFN + (256 – TTI/10msec)) mod 256

MEASUREMENT REPORT (Step 7)

Information Element

Value/remark

Version

Measurement identity

Check to see if set to 3

Measured Results

– CHOICE measurement

Check to see if set to "Inter-RAT measured results list"

– Inter-RAT measured result list

– CHOICE system

GSM

– Measured GSM cells

Check that measurement results for two GSM cells are included

– GSM carrier RSSI

Check that measurement result is reasonable. RXLEV is mapped to a value between 0 and 63. The RSSI bits are numbered b0 to b5, where b0 is the least significant bit. When mapping the RXLEV value to the RSSI bit string, the first/ leftmost bit of the bit string contains the most significant bit.

CHOICE BSIC

Check it is set to verified BSIC

– inter-RAT cell id

Check that it is set to either 0 or 1

– Observed time difference to GSM cell

Check that the IE is not included

R99 and Rel-4 only

– GSM carrier RSSI

Check that measurement result is reasonable

CHOICE BSIC

Verified BSIC

– inter-RAT cell id

Check that is set to 1 if the previous inter-RAT cell id was set to 0 or to 0 if the previous cell if was set to 1.

– Observed time difference to GSM cell

Check that the IE is not present

R99 and Rel-4 only

Measured results on RACH

Check that not present

Additional Measured results

Check that not present

Event results

Check that the IE is included

– CHOICE event result

Check that this is set to inter-RAT measurement event results

– Inter-RAT event identity

Check that this is set to 3c

– Cells to report (1 to <maxCellMeas>)

Check that <maxCellMeas> is set to 1

– CHOICE BSIC

Check that this is set to verified BSIC

– Inter-RAT cell id

Check that this is set to 0.

8.4.1.40.5 Test Requirement

After instant T1, since the cell individual offset for GSM cell 1 is +10 dB, event 3c shall be triggered in the UE, i.e. the UE shall begin to transmit a MEASUREMENT REPORT to the SS. Note that GSM cell 2 has not triggered event 3c even though the RF signal strength for GSM cell 2 is the same as for cell 1, because the cell individual offset for GSM cell 2 is -3 dB.

After instant T2, no MEASUREMENT REPORT shall be received from the UE, since GSM cell 1 has already triggered event 3c, and since the RF signal strength has not dropped enough for the leaving condition to be met.

8.4.1.41 Measurement Control and Report: Additional Measurements list

8.4.1.41.1 Definition

8.4.1.41.2 Conformance requirement

For the measurement, which triggered the MEASUREMENT REPORT message, the UE shall:

…..

1> set the IE "Measured results" in the IE "Additional measured results" according to the IE "reporting quantity" for all measurements associated with the measurement identities included in the "Additional measurements list" stored in variable MEASUREMENT_IDENTITY of the measurement that triggered the measurement report; and

2> if more than one additional measured results are to be included:

  1. include only the available additional measured results, and sort them in ascending order according to their IE "measurement identity" in the MEASUREMENT REPORT message.

……

If the IE "Additional Measurement List" is received in a MEASUREMENT CONTROL message, the UE shall:

1> if the received measurement configuration in this MEASUREMENT CONTROL message, or any measurement referenced in the "Additional Measurement List" do not all have the same validity (for this consistency check the UE should assume "CELL_DCH" as the measurement validity for measurements of type "inter-RAT", "UE internal", and "quality"):

2> set the variable CONFIGURATION_INCOMPLETE to TRUE.

1> if any of the measurements referenced in the "Additional Measurement List" is an intra-frequency, inter-frequency or inter-RAT measurement, and this measurement is configured with event based reporting:

2> the UE behaviour is not specified.

1> if the result of this MEASUREMENT CONTROL message is such that more than one additional measurement of the same type will be referenced in the IE "Additional Measurement List" in the MEASUREMENT_IDENTITY variable:

2> the UE behaviour is not specified.

If the measurement configured with the MEASUREMENT CONTROL message triggers a measurement report, the UE shall also include the reporting quantities for the measurements referenced by the additional measurement identities. The contents of the IE "Additional Measured results" is completely determined by the measurement configuration of the referenced additional measurement.

…..

Reference

3GPP TS 25.331, clause 8.4.2.2, 8.6.7.22

8.4.1.41.3 Test Purpose

1. To confirm that the UE reports measured results for a referenced additional measurement.

2. To confirm that the UE transmits MEASUREMENT REPORT messages for a measurement, also if this measurement is referenced as an additional measurement by another measurement.

8.4.1.41.4 Method of test

Initial Condition

System Simulator: 1 cell, cell 1.

UE: CS-DCCH+DTCH_DCH (State 6-9) or PS-DCCH+DTCH_DCH (State 6-10) in cell 1 as specified in clause 7.4 of TS 34.108, depending on the CN domain supported by the UE.

Test Procedure

The UE is in CELL_DCH state in cell 1, after successfully executing procedures P11 or P13 as specified in clause 7.4 of TS 34.108. Next, SS transmits MEASUREMENT CONTROL message to request the UE to perform UE internal measurements and reporting for events 6A and 6B, followed by a MEASUREMENT CONTROL message to request the UE to perform a periodic intra-frequency measurement. The intra-frequency measurement configuration references as an additional measurement the measurement defined by the first MEASUREMENT CONTROL message.

The UE will start to periodically send MEASUREMENT REPORT messages for the intra-frequency measurement. The reports shall include the UE Tx power as an additional measurement result.

After two MEASUREMENT REPORT messages, the SS increases the UE Tx power above the threshold set to event 6A. After ‘time to trigger’ the UE sends MEASUREMENT REPORT, triggered by event 6A, to the SS.

Next the SS decreases the UE Tx power below the threshold set for event 6B. After ‘time to trigger’ UE sends MEASUREMENT REPORT, triggered by event 6B, to the SS.

Expected Sequence

Step

Direction

Message

Comment

UE

SS

1

void

2

MEASUREMENT CONTROL

SS requests for measurement and reporting for events 6A and 6B.

3

MEASUREMENT CONTROL

SS requests a periodic intra-frequency measurement.

3a

à

MEASUREMENT REPORT

UE shall send a periodical measurement report.

Check the current transmission power of UE from the IE transmitted power FDD or TDD of measurement report.

3b

SS sets the UE transmission power between 6dbm and 18 dBm.

4

MEASUREMENT REPORT

5

MEASUREMENT REPORT

Time difference between earlier and this MEASUREMENT REPORT message should be 32 seconds.

6

SS sets the UE transmission power above 18 dBm.

7

MEASUREMENT REPORT

UE shall send 6A event measurement report.

8

SS sets the UE transmission power below 6 dBm.

9

MEASUREMENT REPORT

UE shall send 6B event measurement report.

Specific Message Content

MEASUREMENT CONTROL (Step 2)(FDD)

Information Element

Value/remark

Measurement Identity

5

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Event Trigger Reporting

Additional measurements list

Not Present

CHOICE measurement type

UE internal measurement

– UE internal measurement

– UE internal measurement quantity

Present

-CHOICE mode

FDD

-UE internal measurement quantity

UE Transmitted Power

-Filter coefficient

0

– UE internal reporting quantity

Present

– UE Transmitted Power

TRUE

– CHOICE mode

FDD

– UE Rx-Tx time difference

FALSE

– CHOICE report criteria

UE internal measurement reporting criteria

– Parameters sent for each UE internal

measurement event

-UE internal event identity

6A

-Time-to-trigger

100 milliseconds

-UE Transmitted Power Tx power threshold

18 dBm

-UE internal event identity

6B

-Time-to-trigger

100 milliseconds

-UE Transmitted Power Tx power threshold

6 dBm

DPCH compressed mode status info

Not Present

MEASUREMENT CONTROL (Step 2)(1.28Mcps TDD)

Information Element

Value/remark

Measurement Identity

5

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Event Trigger Reporting

Additional measurements list

Not Present

CHOICE measurement type

UE internal measurement

– UE internal measurement

– UE internal measurement quantity

Present

-CHOICE mode

TDD

-UE internal measurement quantity

UE Transmitted Power

-Filter coefficient

0

– UE internal reporting quantity

Present

– UE Transmitted Power

TRUE

– CHOICE mode

TDD

– CHOICE TDD option

1.28 Mcps TDD

– TADV info

FALSE

– CHOICE report criteria

UE internal measurement reporting criteria

– Parameters sent for each UE internal

measurement event

-UE internal event identity

6A

-Time-to-trigger

100 milliseconds

-UE Transmitted Power Tx power threshold

18 dBm

-UE internal event identity

6B

-Time-to-trigger

100 milliseconds

-UE Transmitted Power Tx power threshold

6 dBm

DPCH compressed mode status info

Not Present

MEASUREMENT CONTROL (Step 3) (FDD)

Information Element

Value/remark

Measurement Identity

1

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Periodical Reporting

Additional measurements list

– Additional measurement identity

5

CHOICE measurement type

Intra-frequency measurement

– Intra-frequency cell info list

Not Present

– Intra-frequency measurement quantity

– Filter Coefficient

Not Present (Default is 0)

– Measurement quantity

CPICH RSCP

– Intra-frequency reporting quantity

– Reporting quantities for active set cells

– SFN-SFN observed time difference reporting indicator

No report

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CPICH Ec/No reporting indicator

FALSE

– CPICH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting quantities for monitored set cells

– SFN-SFN observed time difference reporting indicator

No report

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CPICH Ec/No reporting indicator

FALSE

– CPICH RSCP reporting indicator

FALSE

– Pathloss reporting indicator

FALSE

– Reporting quantities for detected cells

Not present

– Reporting cell status

– CHOICE reported cell

Report cells within active set

– Maximum number of reported cells

2

– Measurement validity

CELL_DCH

– CHOICE report criteria

Periodical reporting criteria

– Amount of reporting

Infinity

– Reporting interval

32 seconds

DPCH compressed mode status info

Not Present

MEASUREMENT CONTROL (Step 3)( 1.28Mcps TDD)

Information Element

Value/remark

Measurement Identity

1

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Periodical Reporting

Additional measurements list

– Additional measurement identity

5

CHOICE measurement type

Intra-frequency measurement

– Intra-frequency cell info list

Not Present

– Intra-frequency measurement quantity

– Filter Coefficient

Not Present (Default is 0)

– Measurement quantity

PCCPCH RSCP

– Intra-frequency reporting quantity

– Reporting quantities for active set cells

– SFN-SFN observed time difference reporting indicator

No report

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CHOICE mode

TDD

– Timeslot ISCP reporting indicator

FALSE

– Proposed TGSN Reporting required

FALSE

– PCCPCH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting quantities for monitored set cells

– SFN-SFN observed time difference reporting indicator

No report

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CPICH Ec/No reporting indicator

FALSE

– CPICH RSCP reporting indicator

FALSE

– Pathloss reporting indicator

FALSE

– Reporting quantities for detected cells

Not present

– Reporting cell status

– CHOICE reported cell

Report cells within active set

– Maximum number of reported cells

1

– Measurement validity

CELL_DCH

– CHOICE report criteria

Periodical reporting criteria

– Amount of reporting

Infinity

– Reporting interval

32 seconds

DPCH compressed mode status info

Not Present

MEASUREMENT REPORT (Step 3a) (FDD)

Information Element

Value/remark

Measurement identity

Check to see if set to 1

Measured Results

– CHOICE measurement

Check to see if set to "Intra-frequency measured results list"

– Intra-frequency measurement results

– Cell measured results

– Cell Identity

Check to see if this IE is absent

– SFN-SFN observed time difference

Check to see if this IE is absent

– Cell synchronisation information

Check to see if this IE is absent

– Primary CPICH Info

– Primary Scrambling Code

Check to see if it’s the same code for cell 1

– CPICH Ec/No

Check to see if this IE is absent

– CPICH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

Measured Results on RACH

Check to see if this IE is absent

Additional Measured Results

– Measured results

UE internal measured results

– UE transmitted power

Check to see if it is present

– UE RX TX report entry list

Check to see if it is absent

Event Results

Check to see if this IE is absent

MEASUREMENT REPORT (Step 3a) (1.28Mcps TDD)

Information Element

Value/remark

Measurement identity

Check to see if set to 1

Measured Results

– CHOICE measurement

Check to see if set to "Intra-frequency measured results list"

– Intra-frequency measurement results

– Cell measured results

– Cell Identity

Check to see if this IE is absent

– Cell synchronisation information

Check to see if this IE is absent

– CHOICE mode

– Cell parameters Id

Check to see if it’s the same code for cell 1

– Proposed TGSN

Check to see if this IE is absent

– Primary CCPCH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

– Timeslot list

Check to see if this IE is absent

Measured Results on RACH

Check to see if this IE is absent

Additional Measured Results

– Measured results

UE internal measured results

– UE transmitted power

Check to see if it is present

– UE RX TX report entry list

Check to see if it is absent

Event Results

Check to see if this IE is absent

MEASUREMENT REPORT (Step 4 and step 5) (FDD)

Information Element

Value/remark

Measurement identity

Check to see if set to 1

Measured Results

– CHOICE measurement

Check to see if set to "Intra-frequency measured results list"

– Intra-frequency measurement results

– Cell measured results

– Cell Identity

Check to see if this IE is absent

– SFN-SFN observed time difference

Check to see if this IE is absent

– Cell synchronisation information

Check to see if this IE is absent

– Primary CPICH Info

– Primary Scrambling Code

Check to see if it’s the same code for cell 1

– CPICH Ec/No

Check to see if this IE is absent

– CPICH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

Measured Results on RACH

Check to see if this IE is absent

Additional Measured Results

– Measured results

UE internal measured results

– UE transmitted power

Check to see if it is present and value is reasonable

– UE RX TX report entry list

Check to see if it is absent

Event Results

Check to see if this IE is absent

MEASUREMENT REPORT (Step 4 and step 5) (1.28Mcps TDD)

Information Element

Value/remark

Measurement identity

Check to see if set to 1

Measured Results

– CHOICE measurement

Check to see if set to "Intra-frequency measured results list"

– Intra-frequency measurement results

– Cell measured results

– Cell Identity

Check to see if this IE is absent

– Cell synchronisation information

Check to see if this IE is absent

– CHOICE mode

– Cell parameters Id

Check to see if it’s the same code for cell 1

– Proposed TGSN

Check to see if this IE is absent

– Primary CCPCH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

– Timeslot list

Check to see if this IE is absent

Measured Results on RACH

Check to see if this IE is absent

Additional Measured Results

– Measured results

UE internal measured results

– UE transmitted power

Check to see if it is present and value is reasonable

– UE RX TX report entry list

Check to see if it is absent

Event Results

Check to see if this IE is absent

MEASUREMENT REPORT (Step 7) (FDD)

Information Element

Value/remark

Measurement identity

Check to see if set to 5

Measured Results

– CHOICE measurement

Check to see if set to "UE Internal measured results"

– UE internal measured results

-CHOICE mode

Check to see if set to "FDD"

UE Transmitted Power

Check to see if present and value is reasonable

Measured Results on RACH

Check to see if this IE is absent

Event results

-CHOICE event result

Check to see if set to "UE internal measurement event results"

-UE internal event identity

Check to see if set to "6A"

-CHOICE mode

Check to see if set to "FDD"

-Primary CPICH info

Check to see if this IE is absent

MEASUREMENT REPORT (Step 7) (1.28Mcps TDD)

Information Element

Value/remark

Measurement identity

Check to see if set to 5

Measured Results

– CHOICE measurement

Check to see if set to "UE Internal measured results"

– UE internal measured results

-CHOICE mode

Check to see if set to "TDD"

-UE Transmitted Power list

UE Transmitted Power

Check to see if present and value is reasonable

Measured Results on RACH

Check to see if this IE is absent

Event results

-CHOICE event result

Check to see if set to "UE internal measurement event results"

-UE internal event identity

Check to see if set to "6A"

-CHOICE mode

Check to see if set to "TDD"

MEASUREMENT REPORT (Step 9) (FDD)

Information Element

Value/remark

Measurement identity

Check to see if set to 5

Measured Results

– CHOICE measurement

Check to see if set to "UE Internal measured results"

– UE internal measured results

-CHOICE mode

Check to see if set to "FDD"

UE Transmitted Power

Check to see if present and value is reasonable

Measured Results on RACH

Check to see if this IE is absent

Event results

-CHOICE event result

Check to see if set to "UE internal measurement event results"

-UE internal event identity

Check to see if set to "6B"

-CHOICE mode

Check to see if set to "FDD"

-Primary CPICH info

Check to see if this IE is absent

MEASUREMENT REPORT (Step 9) (1.28Mcps TDD)

Information Element

Value/remark

Measurement identity

Check to see if set to 5

Measured Results

– CHOICE measurement

Check to see if set to "UE Internal measured results"

– UE internal measured results

-CHOICE mode

Check to see if set to "TDD"

-UE Transmitted Power list

UE Transmitted Power

Check to see if present and value is reasonable

Measured Results on RACH

Check to see if this IE is absent

Event results

-CHOICE event result

Check to see if set to "UE internal measurement event results"

-UE internal event identity

Check to see if set to "6B"

-CHOICE mode

Check to see if set to "TDD"

8.4.1.41.5 Test Requirement

After step 3, the UE shall periodically transmit a MEASUREMENT REPORT message for measurement identity 5. In addition to the CPICH RSCP, these reports shall also include the UL Tx power with a reasonable value.

After step 6, the UE shall transmit a MEASUREMENT REPORT message, containing measured results for UE transmitted power. The ‘Event results’ IE contains event identity 6A.

After step 8, the UE shall transmit a MEASUREMENT REPORT message, containing measured results for UE transmitted power. The ‘Event results’ IE contains event identity 6B.

8.4.1.42 Measurement Control and Report: Change of Compressed Mode Method

8.4.1.42.1 Definition

8.4.1.42.2 Conformance requirement

If variable INVALID_CONFIGURATION has value FALSE after UE has performed the checks above, the UE shall:

1> if pattern sequence corresponding to IE "TGPSI" is already active (according to "Current TGPS Status Flag") in the variable TGPS_IDENTITY):

2> if the "TGPS Status Flag" in this message is set to "deactivate" for the corresponding pattern sequence:

3> deactivate this pattern sequence at the beginning of the frame, indicated by IE "Activation time"(see subclause 8.6.3.1) received in this message, when the new configuration received in this message is taken into use.

3> set the "Current TGPS Status Flag" for this pattern sequence in the variable TGPS_IDENTITY to "inactive" at the frame, indicated by IE "Activation time" (see subclause 8.6.3.1) received in this message, when the new configuration received in this message is taken into use.

2> if the "TGPS Status Flag" in this message is set to "activate" for the corresponding pattern sequence:

3> deactivate this pattern sequence at the beginning of the frame, indicated by IE "Activation time"(see subclause 8.6.3.1) received in this message, when the new configuration received in this message is taken into use.

NOTE1: The temporary deactivation of pattern sequences for which the status flag is set to "activate" can be used by the network to align the timing of already active patterns with newly activated patterns.

NOTE2: The deactivation of pattern sequences only occurs as a result of RRC messages received by the UE, i.e. the UE does not set the "Current TGPS Status Flag" to "inactive" after the final gap of a finite length pattern sequence.

1> update each pattern sequence to the variable TGPS_IDENTITY according to the IE "TGPSI";

1> update into the variable TGPS_IDENTITY the configuration information defined by IE group" transmission gap pattern sequence configuration parameters ";

1> after the instant in which the message is to be executed, as specified in subclause 8.6.3.1:

2> activate the stored pattern sequence corresponding to each IE "TGPSI" for which the "TGPS status flag" in the variable TGPS_IDENTITY is set to "activate" at the time indicated by IE "TGCFN"; and

2> set the "Current TGPS Status Flag" for this pattern sequence in the variable TGPS_IDENTITY to "active".

NOTE1: If the pattern is activated with a message that includes the IE "Activation time", and if the CFN value indicated by the IE "Activation Time" and the CFN value indicated by the TGCFN are included in the same TTI (but not at the TTI boundary) common to all the transport channels that are multiplexed onto the reference CCTrCh (as defined in subclause 8.6.3.1), and if the CFN value indicated by the TGCFN is equal or higher than the CFN value indicated by the IE "Activation Time" (as defined in subclause 8.6.3.1) value, the UE behaviour is not specified.

NOTE2: If the pattern is activated with a message used to perform timing re-initialised hard handover, the UE can start evaluating the activation of the pattern (i.e. compare the value of the CFN in the new configuration with the value of the TGCFN) at any time between the message activation time and the completion of the synchronisation procedure A.

2> if the IE "DPCH compressed mode info" is included in a message used to perform a Hard Handover with change of frequency (see subclause 8.3.5); or

2> if the IE "DPCH compressed mode info" is included in a message used to transfer the UE from Cell_FACH to Cell_DCH, and the cell in which the UE transited from CELL_FACH state is not included in the active set for the CELL_DCH state (see subclause 8.4.1.7.2):

3> not begin the inter-frequency measurement reporting corresponding to the pattern sequence measurement purpose of each activated pattern sequence.

2> else:

3> begin the inter-frequency measurement reporting corresponding to the pattern sequence measurement purpose of each activated pattern sequence.

2> begin the inter-RAT measurement reporting corresponding to the pattern sequence measurement purpose of each activated pattern sequence;

2> if the new configuration is taken into use at the same CFN as indicated by IE "TGCFN":

3> start the concerned pattern sequence immediately at that CFN.

1> monitor if the parallel transmission gap pattern sequences create an illegal overlap, and in case of overlap, take actions as specified in subclause 8.2.11.2.

….

Uplink and downlink compressed mode methods are described in TS 25.212. For UL "higher layer scheduling" compressed mode method and transport format combination selection, see TS 25.321.

Reference

3GPP TS 25.331 clause 8.6.6.15.

8.4.1.42.3 Test purpose

To confirm that the UE supports change of compressed mode method included in a RADIO BEARER SETUP message.

To confirm that the UE supports change of compressed mode method included in a RADIO BEARER RELEASE message.

8.4.1.42.4 Method of test

Initial Condition

System Simulator: 3 cells – Cell 1 on frequency f1, cell 4 on frequency f2 and cell 5 on frequency f3.

UE: "PS-DCCH_DCH" (state 6-7) as specified in clause 7.4 of TS 34.108.

This test case applies only for UEs requiring compressed mode to perform inter- frequency measurements and supporting both PS and CS domains.

Test Procedure

Table 8.4.1.42-1 illustrates the downlink power to be applied for the 3 cells, as well as the frequency and scrambling code for each cell.

Table 8.4.1.42-1a

Parameter

Unit

Cell 1

Frequency

f1

Scrambling code

Scrambling code 1

T0

T1

T2

T3

T4

T5

CPICH Ec

dBm/3.84 MHz

-60

-70

-70

-60

-70

-70

Table 8.4.1.42-1b

Parameter

Unit

Cell 4

Cell 5

Frequency

f2

f3

Scrambling code

Scrambling code 3

Scrambling code 2

T0

T1

T2

T3

T4

T5

T0

T1

T2

T3

T4

T5

CPICH Ec

dBm/3.84 MHz

-95

-60

-60

-95

-60

-60

-95

-95

-60

-95

-95

-60

The UE is initially in CELL_DCH, and has only cell 1 in its active set.

The SS transmits a PHYSICAL CHANNEL RECONFIGURATION message to download compressed mode parameters in the UE but without activating compressed mode. The UE shall answer with a PHYSICAL CHANNEL RECONFIGURATION COMPLETE message.

The SS then sets up inter-frequency measurements (event 2b), by sending a MEASUREMENT CONTROL message to the UE.

The SS waits for 2560 ms for the UE to activate compressed mode.

At instant T1, the downlink power is changed according to what is shown in table 8.4.1.42-1. Frequency f2 shall then trigger event 2b, and the UE shall transmit a MEASUREMENT REPORT message to the SS.

The SS establishes PS domain RAB and changes compressed mode method (from SF/2 to HLS) by sending a RADIO BEARER SETUP message on DCCH using AM-RLC. The UE shall answer with a RADIO BEARER SETUP COMPLETE message.

At instant T2, the downlink power is changed according to what is shown in table 8.4.1.42-1. Frequency f3 shall then trigger event 2b, and the UE shall transmit a MEASUREMENT REPORT message to the SS.

At instant T3, the downlink power is changed according to what is shown in table 8.4.1.42-1.The increased quality of the used frequency should result in clearing of the concerning TRIGGERED_2B_EVENT.

The SS initiates an MT CS call, establishes a CS domain RAB and changes the compressed mode method to (from HLS to SF/2), by sending a RADIO BEARER SETUP message on DCCH using AM-RLC. The UE shall answer with a RADIO BEARER SETUP COMPLETE message.

At instant T4, the downlink power is changed according to what is shown in table 8.4.1.42-1. Frequency f2 shall then trigger event 2b, and the UE shall transmit a MEASUREMENT REPORT message to the SS.

Next, the SS releases the CS domain RAB and changes compressed mode method (from SF/2 to HLS) by sending a RADIO BEARER RELEASE message on DCCH using AM-RLC. The UE shall answer with a RADIO BEARER RELEASE COMPLETE message.

At instant T5, the downlink power is changed according to what is shown in table 8.4.1.42-1. Frequency f3 shall then trigger event 2b, and the UE shall transmit a MEASUREMENT REPORT message to the SS.

Expected Sequence

Step

Direction

Message

Comment

UE

SS

1

PHYSICAL CHANNEL RECONFIGURATION

SS downloads compressed mode parameters (using SF/2 method) without activating compressed mode

2

PHYSICAL CHANNEL RECONFIGURATION COMPLETE

The UE acknowledges the downloading of compressed mode parameters

3

MEASUREMENT CONTROL

The SS configures inter-frequency measurements in the UE and activates compressed mode

4

The SS changes the power of the cells according to column T1 in table 8.4.1.42-1.

5

MEASUREMENT REPORT

Frequency f2 triggers event 2b in the UE, which sends a MEASUREMENT REPORT message to the SS.

5a

RADIO BEARER SETUP

SS establishes PS domain RAB and changes compressed mode method to HLS.

5b

RADIO BEARER SETUP COMPLETE

The UE acknowledges the establishment of the RAB and the compressed mode method change.

5c

The SS changes the power of the cells according to column T2 in table 8.4.1.42-1.

5d

MEASUREMENT REPORT

Frequency f3 triggers event 2b in the UE, which sends a MEASUREMENT REPORT message to the SS.

5e

The SS changes the power of the cells according to T3 in table 8.4.1.42-1 (so the UE can trigger event 2b again for both frequencies if suitable conditions arise)

5f

PAGING TYPE 2

Initiates MT CS call

5g

INITIAL DIRECT TRANSFER

(PAGING RESPONSE)

RR

5h

DOWNLINK DIRECT TRANSFER

(AUTHENTICATION REQUEST)

MM

5i

UPLINK DIRECT TRANSFER

(AUTHENTICATION RESPONSE)

MM

5j

SECURITY MODE COMMAND

5k

SECURITY MODE COMPLETE

5l

DOWNLINK DIRECT TRANSFER

(SET UP)

CC

5m

UPLINK DIRECT TRANSFER

(CALL CONFIRMED)

CC

6

RADIO BEARER SETUP

SS establishes CS domain RAB and changes to SF/2 compressed mode method

7

RADIO BEARER SETUP COMPLETE

The UE acknowledges the establishment of the RAB and the compressed mode method change.

7a

UPLINK DIRECT TRANSFER

(ALERTING)

CC (This message is optional)

7b

UPLINK DIRECT TRANSFER

(CONNECT)

CC

7c

DOWNLINK DIRECT TRANSFER

(CONNECT ACKNOWLEDGE)

CC

8

The SS changes the power of the cells according to column T4 in table 8.4.1.42-1.

9

MEASUREMENT REPORT

Frequency f2 triggers event 2b in the UE, which sends a MEASUREMENT REPORT message to the SS.

10

Void

11

Void

12

Void

13

Void

14

Void

15

RADIO BEARER RELEASE

SS releases the CS domain RAB and changes compressed mode method toHLS.

16

RADIO BEARER RELEASE COMPLETE

The UE acknowledges the release of the RAB and the compressed mode method change.

17

The SS changes the power of the cells according to column T5 in table 8.4.1.42-1.

18

MEASUREMENT REPORT

Frequency f3 triggers event 2b in the UE, which sends a MEASUREMENT REPORT message to the SS.

Specific Message Content

All messages shall use the same content as defined in [9] TS 34.108 clause 9, with the following exceptions:

PHYSICAL CHANNEL RECONFIGURATION MESSAGE (Step 1)

Information Element

Value/Remark

Version

Activation time

Not Present

New U-RNTI

Not Present

New C-RNTI

Not Present

New DSCH-RNTI

Not Present

RRC State indicator

CELL_DCH

UTRAN DRX cycle length coefficient

Not Present

CN information info

Not Present

URA identity

Not Present

Downlink counter synchronisation info

Not Present

Frequency info

Not Present

Maximum allowed UL TX power

Not Present

CHOICE channel requirement

Not Present

CHOICE mode

FDD

– Downlink PDSCH information

Not Present

Downlink information common for all radio links

– Downlink DPCH info common for all RL

Not Present

– DPCH compressed mode info

– TGPSI

1

– TGPS Status Flag

Deactivate

– TGCFN

Not present

– Transmission gap pattern sequence configuration parameters

– TGMP

FDD Measurement

– TGPRC

Infinity

– TGSN

4

– TGL1

7

– TGL2

Not Present

– TGD

undefined

– TGPL1

3

– TGPL2

Not Present

R99 and REL-4 only

– RPP

Mode 0

– ITP

Mode 0

– CHOICE UL/DL Mode

UL and DL, UL only or DL only (depending on the UE capability)

– Downlink compressed mode method

SF/2 (or not sent, depending on the UE capability)

– Uplink compressed mode method

SF/2 (or not sent, depending on the UE capability)

– Downlink frame type

B

– DeltaSIR1

20 (2.0)

– DeltaSIRAfter1

10 (1.0)

– DeltaSIR2

Not Present

– DeltaSIRAfter2

Not Present

– N identify abort

Not Present

– T Reconfirm abort

Not Present

– TX Diversity mode

Not Present

– SSDT information

Not Present

R99 and Rel-4 only

– Default DPCH Offset Value

Not Present

Downlink information for each radio link

Same as the set defined in RADIO BEARER SETUP message found in TS 34.108 clause 9 under condition A3.

MEASUREMENT CONTROL (Step 3)

Information Element

Value/Remark

Measurement Identity

2

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodical Reporting / Event Trigger Reporting Mode

Event Trigger

Additional measurements list

Not Present

CHOICE measurement type

Inter-frequency measurement

– Inter-frequency cell info list

– CHOICE inter-frequency cell removal

No inter-frequency cells removed

– New inter-frequency info list

2 inter-frequency cells

– Inter-frequency cell id

4

– Frequency info

– UARFCN uplink (Nu)

Not present

Absence of this IE is equivalent to applying the default duplex distance defined for the operating frequency according to 3GPP TS 25.101 [21]

– UARFCN downlink (Nd)

UARFCN for the downlink corresponding to f2

– Cell info

– Cell individual offset

0 dB

– Reference time difference to cell

Not present

– Read SFN Indicator

FALSE

– CHOICE Mode

FDD

– Primary CPICH Info

– Primary Scrambling Code

Scrambling code 3

– Primary CPICH TX power

Not Present

– TX Diversity Indicator

FALSE

– Inter-frequency cell id

5

– Frequency info

– UARFCN uplink (Nu)

Not present

Absence of this IE is equivalent to applying the default duplex distance defined for the operating frequency according to 3GPP TS 25.101 [21]

– UARFCN downlink (Nd)

UARFCN for the downlink corresponding to f3

– Cell info

– Cell individual offset

0 dB

– Reference time difference to cell

Not present

– Read SFN Indicator

FALSE

– CHOICE Mode

FDD

– Primary CPICH Info

Not present

– Primary Scrambling Code

Scrambling code 2

– Primary CPICH TX power

Not Present

– TX Diversity Indicator

FALSE

– Cells for measurement

Not present

– Inter-frequency measurement quantity

– CHOICE reporting criteria

Inter-frequency reporting criteria

– Filter Coefficient

0

– Measurement quantity for frequency quality estimate

CPICH RSCP

– Inter-frequency reporting quantity

– UTRA Carrier RSSI

FALSE

– Frequency quality estimate

FALSE

– Non frequency related cell reporting quantities

– SFN-SFN observed time difference reporting indicator

No report

– Cell synchronisation information reporting indicator

FALSE

– Cell Identity reporting indicator

TRUE

– CPICH Ec/No reporting indicator

FALSE

– CPICH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting cell status

Not present

– Measurement validity

– UE State

CELL_DCH

– Inter-frequency set update

– UE autonomous update

On with no reporting

– Non autonomous update mode

Not present

– CHOICE report criteria

Inter-frequency measurement reporting criteria

– Parameters required for each event

– Inter-frequency event identity

2b

– Threshold used frequency

-65 dBm

– W used frequency

0.0

– Hysteresis

2 (1 dB)

– Time to trigger

100 ms

– Reporting cell status

Report cells within monitored and/or virtual active set on non-used frequency

– Maximum number of reported cells per
reported non-used frequency

2

– Parameters required for each non-used
frequency

– Threshold non used frequency

-68 dBm

– W non-used frequency

0

DPCH compressed mode status info

– TGPS reconfiguration CFN

(Current CFN + (256 – TTI/10msec))mod 256

– Transmission gap pattern sequence

– TGPSI

1

– TGPS Status Flag

Activate

– TGCFN

(Current CFN + (256 – TTI/10msec))mod 256

MEASUREMENT REPORT (Step 5,9)

Information Element

Value/Remark

Message Type

Integrity check info

– Message authentication code

This IE is checked to see if it is present. The value is compared against the XMAC-I value computed by SS. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I.

– RRC Message sequence number

This IE is checked to see if it is present. The value is used by SS to compute the XMAC-I value.

Measurement identity

2

Measured Results

– Inter-frequency measured results list

– Frequency info

-CHOICE mode

FDD

– UARFCN uplink

The presence of this IE is not checked

– UARFCN downlink

Check that the value of this IE is set to UARFCN for the downlink corresponding to f2

– UTRA carrier RSSI

Check that this IE is absent

– Inter-frequency cell measurement results

Check that the value of this IE is set to 1 cell reported

– Cell measured results

– Cell Identity

Check that this IE is absent

– SFN-SFN observed time difference

Check that this IE is absent

– Cell synchronisation information

Check that this IE is absent

– Primary CPICH info

– Primary scrambling code

Check that the value of this IE is set to Scrambling code 3

– CPICH Ec/N0

Check that this IE is absent

– CPICH RSCP

Check that this IE is present

– Pathloss

Check that this IE is absent

Measured results on RACH

Check that this IE is absent

Additional measured results

Check that this IE is absent

Event results

– Inter-frequency measurement event results

– Inter-frequency event identity

2b

– Inter-frequency cells

– Frequency info

-CHOICE mode

FDD

– UARFCN uplink

The presence of this IE is not checked

– UARFCN downlink

Check that the value of this IE is set to UARFCN for the downlink corresponding to f2

– Non freq related measurement event results

– Primary CPICH info

– Primary scrambling code

Check that the value of this IE is set to Scrambling code 3

RADIO BEARER SETUP (Step 5a)

Use the same message sub-type found in TS 34.108 clause 9, which is entitled "Packet to CELL_DCH from CELL_DCH in PS", with Scrambling code change set to Default1 and with the following modifications:

Information Element

Value/Remark

Version

– DPCH compressed mode info

– TGPSI

1

– TGPS Status Flag

Activate

– TGCFN

(Current CFN + (256 – TTI/10msec))mod 256

– Transmission gap pattern sequence configuration parameters

– TGMP

FDD Measurement

– TGPRC

Infinity

– TGSN

4

– TGL1

7

– TGL2

Not Present

– TGD

undefined

– TGPL1

3

– TGPL2

Not Present

R99 and REL-4 only

– RPP

Mode 0

– ITP

Mode 0

– CHOICE UL/DL Mode

UL and DL, UL only or DL only (depending on the UE capability)

– Downlink compressed mode method

HLS(or not sent, depending on the UE capability)

– Uplink compressed mode method

HLS(or not sent, depending on the UE capability)

– Downlink frame type

B

– DeltaSIR1

20 (2.0)

– DeltaSIRAfter1

10 (1.0)

– DeltaSIR2

Not Present

– DeltaSIRAfter2

Not Present

– N identify abort

Not Present

– T Reconfirm abort

Not Present

Downlink information for each radio link list

 

 

– Downlink information for each radio link

 

 

– Choice mode

FDD

 

– Primary CPICH info

 

 

– Primary scrambling code

Ref. to the Default setting in clause 6.1 (FDD)

 

– PDSCH with SHO DCH info

Not Present

R99 and Rel-4 only

– PDSCH code mapping

Not Present

R99 and Rel-4 only

– Serving HS-DSCH radio link indicator

FALSE

Rel-5

– Downlink DPCH info for each RL

 

 

– Primary CPICH usage for channel estimation

Primary CPICH may be used

 

– DPCH frame offset

Set to value Default DPCH Offset Value (as currently stored in SS) mod 38 400

 

– Secondary CPICH info

Not Present

 

– DL channelisation code

 

 

– Secondary scrambling code

1

 

– Spreading factor

Reference to clause 6.10 Parameter Set

 

– Code number

0

 

– Scrambling code change

Set to value Default1: No code change (if the UE has a compressed mode pattern sequence configured in variable TGPS_IDENTITY or included in the message including IE "Downlink DPCH info for each RL", which is using compressed mode method "SF/2")

– TPC combination index

0

 

– SSDT Cell Identity

Not Present

R99 and Rel-4 only

– Closed loop timing adjustment mode

Not Present

 

– SCCPCH information for FACH

Not Present

R99 and Rel-4 only  

Downlink information for each radio link list

 

 

– Downlink information for each radio link

 

 

– Choice mode

FDD

 

– Primary CPICH info

 

 

– Primary scrambling code

Ref. to the Default setting in clause 6.1 (FDD)

 

– PDSCH with SHO DCH info

Not Present

R99 and Rel-4 only

– PDSCH code mapping

Not Present

R99 and Rel-4 only

– Serving HS-DSCH radio link indicator

FALSE

Rel-5

– Downlink DPCH info for each RL

Not present

 

– SCCPCH information for FACH

Not Present

R99 and Rel-4 only   

PAGING TYPE 2 (Step 5f)

Use the same message type found in TS 34.108 clause 9.

RADIO BEARER SETUP (Step 6)

Use the same message sub-type found in TS 34.108 clause 9, which is entitled "Non speech to CELL_DCH from CELL_DCH in CS" or "Speech to CELL_DCH from CELL_DCH in CS", with Scrambling code change set to Default1 and with the following modifications:

Information Element

Value/Remark

Version

– DPCH compressed mode info

– TGPSI

1

– TGPS Status Flag

Activate

– TGCFN

(Current CFN + (256 – TTI/10msec))mod 256

– Transmission gap pattern sequence configuration parameters

– TGMP

FDD Measurement

– TGPRC

Infinity

– TGSN

4

– TGL1

7

– TGL2

Not Present

– TGD

undefined

– TGPL1

3

– TGPL2

Not Present

R99 and REL-4 only

– RPP

Mode 0

– ITP

Mode 0

– CHOICE UL/DL Mode

UL and DL, UL only or DL only (depending on the UE capability)

– Downlink compressed mode method

SF/2(or not sent, depending on the UE capability)

– Uplink compressed mode method

SF/2(or not sent, depending on the UE capability)

– Downlink frame type

B

– DeltaSIR1

20 (2.0)

– DeltaSIRAfter1

10 (1.0)

– DeltaSIR2

Not Present

– DeltaSIRAfter2

Not Present

– N identify abort

Not Present

– T Reconfirm abort

Not Present

Downlink information for each radio link list

 

 

– Downlink information for each radio link

 

 

– Choice mode

FDD

 

– Primary CPICH info

 

 

– Primary scrambling code

Ref. to the Default setting in clause 6.1 (FDD)

 

– PDSCH with SHO DCH info

Not Present

R99 and Rel-4 only

– PDSCH code mapping

Not Present

R99 and Rel-4 only

– Serving HS-DSCH radio link indicator

FALSE

Rel-5

– Downlink DPCH info for each RL

 

 

– Primary CPICH usage for channel estimation

Primary CPICH may be used

 

– DPCH frame offset

Set to value Default DPCH Offset Value (as currently stored in SS) mod 38 400

 

– Secondary CPICH info

Not Present

 

– DL channelisation code

 

 

– Secondary scrambling code

1

 

– Spreading factor

Reference to clause 6.10 Parameter Set

 

– Code number

0

 

– Scrambling code change

Set to value Default1: No code change (if the UE has a compressed mode pattern sequence configured in variable TGPS_IDENTITY or included in the message including IE "Downlink DPCH info for each RL", which is using compressed mode method "SF/2")

– TPC combination index

0

 

– SSDT Cell Identity

Not Present

R99 and Rel-4 only

– Closed loop timing adjustment mode

Not Present

 

– SCCPCH information for FACH

Not Present

R99 and Rel-4 only  

Downlink information for each radio link list

 

 

– Downlink information for each radio link

 

 

– Choice mode

FDD

 

– Primary CPICH info

 

 

– Primary scrambling code

Ref. to the Default setting in clause 6.1 (FDD)

 

– PDSCH with SHO DCH info

Not Present

R99 and Rel-4 only

– PDSCH code mapping

Not Present

R99 and Rel-4 only

– Serving HS-DSCH radio link indicator

FALSE

Rel-5

– Downlink DPCH info for each RL

Not present

– SCCPCH information for FACH

Not Present

R99 and Rel-4 only

MEASUREMENT REPORT (Step 5d,18)

NOTE: Due to ambiguity in 25.331 clause 14.2.1.2 – two interpretations can be given for MEASUREMENT REPORT

Information Element

Value/Remark

Message Type

Integrity check info

– Message authentication code

This IE is checked to see if it is present. The value is compared against the XMAC-I value computed by SS. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I.

– RRC Message sequence number

This IE is checked to see if it is present. The value is used by SS to compute the XMAC-I value.

Measurement identity

2

Measured Results

– Inter-frequency measured results list

– Frequency info

-CHOICE mode

FDD

– UARFCN uplink

The presence of this IE is not checked

– UARFCN downlink

Check that the value of this IE is set to UARFCN for the downlink corresponding to f3

– UTRA carrier RSSI

Check that this IE is absent

– Inter-frequency cell measurement results

Check that the value of this IE is set to 1 cell reported

– Cell measured results

– Cell Identity

Check that this IE is absent

– SFN-SFN observed time difference

Check that this IE is absent

– Cell synchronisation information

Check that this IE is absent

– Primary CPICH info

– Primary scrambling code

Check that the value of this IE is set to Scrambling code 2 (on f3)

– CPICH Ec/N0

Check that this IE is absent

– CPICH RSCP

Check that this IE is present

– Pathloss

Check that this IE is absent

Measured results on RACH

Check that this IE is absent

Additional measured results

Check that this IE is absent

Event results

– Inter-frequency measurement event results

– Inter-frequency event identity

2b

– Inter-frequency cells

– Frequency info

-CHOICE mode

FDD

– UARFCN uplink

The presence of this IE is not checked

– UARFCN downlink

Check that the value of this IE is set to UARFCN for the downlink corresponding to f3

– Non freq related measurement event results

– Primary CPICH info

– Primary scrambling code

Check that the value of this IE is set to Scrambling code 2 (on f3)

OR:

Information Element

Value/Remark

Message Type

Integrity check info

– Message authentication code

This IE is checked to see if it is present. The value is compared against the XMAC-I value computed by SS. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I.

– RRC Message sequence number

This IE is checked to see if it is present. The value is used by SS to compute the XMAC-I value.

Measurement identity

2

Measured Results

– Inter-frequency measured results list

Check to see if measurement results for 2 cells are included (the order in which the different cells are reported is not important)

– Frequency info

-CHOICE mode

FDD

– UARFCN uplink

Check that the value of this IE is set to UARFCN for the uplink corresponding to f2 (Could be absent in case the duplex distance is the default duplex distance)

– UARFCN downlink

Check that the value of this IE is set to UARFCN for the downlink corresponding to f2

– UTRA carrier RSSI

Check that this IE is absent

– Inter-frequency cell measurement results

Check that the value of this IE is set to 2 cells reported

– Cell measured results

– Cell Identity

Check that this IE is absent

– SFN-SFN observed time difference

Check that this IE is absent

– Cell synchronisation information

Check that this IE is absent

– Primary CPICH info

– Primary scrambling code

Check that the value of this IE is set to Scrambling code 3 (on f2)

– CPICH Ec/N0

Check that this IE is absent

– CPICH RSCP

Check that this IE is present

– Pathloss

Check that this IE is absent

– Frequency info

-CHOICE mode

FDD

– UARFCN uplink

Check that the value of this IE is set to UARFCN for the uplink corresponding to f3(Could be absent in case the duplex distance is the default duplex distance)

– UARFCN downlink

Check that the value of this IE is set to UARFCN for the downlink corresponding to f3

– UTRA carrier RSSI

Check that this IE is absent

– Inter-frequency cell measurement results

– Cell measured results

– Cell Identity

Check that this IE is absent

– SFN-SFN observed time difference

Check that this IE is absent

– Cell synchronisation information

Check that this IE is absent

– Primary CPICH info

– Primary scrambling code

Check that the value of this IE is set to Scrambling code Scrambling code 2 (on f3)

– CPICH Ec/N0

Check that this IE is absent

– CPICH RSCP

Check that this IE is present

– Pathloss

Check that this IE is absent

Measured results on RACH

Check that this IE is absent

Additional measured results

Check that this IE is absent

Event results

– Inter-frequency measurement event results

Check to see if event results for 2 cells are included (the order in which the different cells are reported is not important)

– Inter-frequency event identity

2b

– Inter-frequency cells

– Frequency info

-CHOICE mode

FDD

– UARFCN uplink

Check that the value of this IE is set to UARFCN for the uplink corresponding to f2 (Could be absent in case the duplex distance is the default duplex distance)

– UARFCN downlink

Check that the value of this IE is set to UARFCN for the downlink corresponding to f2

– Non freq related measurement event results

– Primary CPICH info

– Primary scrambling code

Check that the value of this IE is set to Scrambling code 3 (on f2)

– Frequency info

-CHOICE mode

FDD

– UARFCN uplink

Check that the value of this IE is set to UARFCN for the uplink corresponding to f3(Could be absent in case the duplex distance is the default duplex distance)

– UARFCN downlink

Check that the value of this IE is set to UARFCN for the downlink corresponding to f3

– Non freq related measurement event results

– Primary CPICH info

– Primary scrambling code

Check that the value of this IE is set to Scrambling code 2 (on f3)

RADIO BEARER RELEASE (Step 15)

Use the same message sub-type found in TS 34.108 clause 9, which is entitled “Non speech in CS” or "Speech in CS", with Scrambling code change set to Default1 and with the following modifications

Information Element

Value/Remark

Version

– DPCH compressed mode info

– TGPSI

1

– TGPS Status Flag

Activate

– TGCFN

(Current CFN + (256 – TTI/10msec))mod 256

– Transmission gap pattern sequence configuration parameters

– TGMP

FDD Measurement

– TGPRC

Infinity

– TGSN

4

– TGL1

7

– TGL2

Not Present

– TGD

undefined

– TGPL1

3

– TGPL2

Not Present

R99 and REL-4 only

– RPP

Mode 0

– ITP

Mode 0

– CHOICE UL/DL Mode

UL and DL, UL only or DL only (depending on the UE capability)

– Downlink compressed mode method

HLS(or not sent, depending on the UE capability)

– Uplink compressed mode method

HLS(or not sent, depending on the UE capability)

– Downlink frame type

B

– DeltaSIR1

20 (2.0)

– DeltaSIRAfter1

10 (1.0)

– DeltaSIR2

Not Present

– DeltaSIRAfter2

Not Present

– N identify abort

Not Present

– T Reconfirm abort

Not Present

Downlink information for each radio link list

-Downlink information for each radio link

– Choice mode

FDD

– Primary CPICH info

– Primary scrambling code

Ref. to the Default setting in clause 6.1 (FDD)

– PDSCH with SHO DCH info

Not Present

R99 and Rel-4 only

– PDSCH code mapping

Not Present

R99 and Rel-4 only

– Serving HS-DSCH radio link indicator

FALSE

Rel-5

– Serving E-DCH radio link indicator

FALSE

Rel-6

– Downlink DPCH info for each RL

– Primary CPICH usage for channel estimation

Primary CPICH may be used

– DPCH frame offset

Set to value Default DPCH Offset Value (as currently stored in SS) mod 38 400

– Secondary CPICH info

Not Present

– Secondary scrambling code

– channelisation code

– DL channelisation code

– Secondary scrambling code

3

– Spreading factor

Reference to clause 6.10 Parameter Set

– Code number

0

– Scrambling code change

Set to value Default1: No code change (if the UE has a compressed mode pattern sequence configured in variable TGPS_IDENTITY or included in the message including IE "Downlink DPCH info for each RL", which is using compressed mode method "SF/2")

Set to value: OMIT (otherwise)

Default2

– TPC combination index

0

– SSDT Cell Identity

Not Present

R99 and Rel-4 only

– Closed loop timing adjustment mode

Not Present

– E-AGCH Info

Not present

Rel-6

– E-HICH Information

Not present

Rel-6

– E-RGCH Information

Not present

Rel-6

– SCCPCH information for FACH

Not Present

R99 and Rel-4 only

8.4.1.42.5 Test Requirement

After step 1, the UE shall transmit a PHYSICAL CHANNEL RECONFIGURATION COMPLETE message to the SS to acknowledge the downloading of compressed mode parameters that were included in the PHYSICAL CHANNEL RECONFIGURATION message of step 1.

After step 4, the UE shall transmit a MEASUREMENT REPORT message triggered by frequency f2. That message shall only include cell 4 within the IE event results.

After step 5a, the UE shall send a RADIO BEARER SETUP COMPLETE message to the SS to acknowledge the establishment of the RAB and the change of compressed mode method that were included in the RADIO BEARER SETUP message of step 5a.

After step 5c, the UE shall transmit a MEASUREMENT REPORT message triggered by frequency f3.

After step 6, the UE shall send a RADIO BEARER SETUP COMPLETE message to acknowledge the establishment of the RAB and the compressed mode method change that were included in the RADIO BEARER SETUP message of step 6.

After step 8, the UE shall transmit a MEASUREMENT REPORT message triggered by frequency f2. That message shall only include cell 4 within the IE event results.

After step 15, the UE shall send a RADIO BEARER RELEASE COMPLETE message to acknowledge the release of the RAB and the compressed mode method change that were included in the RADIO BEARER RELEASE message of step 15.

After step 17, the UE shall transmit a MEASUREMENT REPORT message triggered by frequency f3.

8.4.1.43 Measurement Control and Report: Compressed Mode Reconfiguration

8.4.1.43.1 Definition

8.4.1.43.2 Conformance requirement

If variable INVALID_CONFIGURATION has value FALSE after UE has performed the checks above, the UE shall:

1> if pattern sequence corresponding to IE "TGPSI" is already active (according to "Current TGPS Status Flag") in the variable TGPS_IDENTITY):

2> if the "TGPS Status Flag" in this message is set to "deactivate" for the corresponding pattern sequence:

3> deactivate this pattern sequence at the beginning of the frame, indicated by IE "Activation time"(see subclause 8.6.3.1) received in this message, when the new configuration received in this message is taken into use.

3> set the "Current TGPS Status Flag" for this pattern sequence in the variable TGPS_IDENTITY to "inactive" at the frame, indicated by IE "Activation time" (see subclause 8.6.3.1) received in this message, when the new configuration received in this message is taken into use.

2> if the "TGPS Status Flag" in this message is set to "activate" for the corresponding pattern sequence:

3> deactivate this pattern sequence at the beginning of the frame, indicated by IE "Activation time"(see subclause 8.6.3.1) received in this message, when the new configuration received in this message is taken into use.

NOTE 1: The temporary deactivation of pattern sequences for which the status flag is set to "activate" can be used by the network to align the timing of already active patterns with newly activated patterns.

NOTE 2: The deactivation of pattern sequences only occurs as a result of RRC messages received by the UE, i.e. the UE does not set the "Current TGPS Status Flag" to "inactive" after the final gap of a finite length pattern sequence.

1> update each pattern sequence to the variable TGPS_IDENTITY according to the IE "TGPSI";

1> update into the variable TGPS_IDENTITY the configuration information defined by IE group" transmission gap pattern sequence configuration parameters ";

1> after the instant in which the message is to be executed, as specified in subclause 8.6.3.1:

2> activate the stored pattern sequence corresponding to each IE "TGPSI" for which the "TGPS status flag" in the variable TGPS_IDENTITY is set to "activate" at the time indicated by IE "TGCFN"; and

2> set the "Current TGPS Status Flag" for this pattern sequence in the variable TGPS_IDENTITY to "active".

NOTE 1: If the pattern is activated with a message that includes the IE "Activation time", and if the CFN value indicated by the IE "Activation Time" and the CFN value indicated by the TGCFN are included in the same TTI (but not at the TTI boundary) common to all the transport channels that are multiplexed onto the reference CCTrCh (as defined in subclause 8.6.3.1), and if the CFN value indicated by the TGCFN is equal or higher than the CFN value indicated by the IE "Activation Time" (as defined in subclause 8.6.3.1) value, the UE behaviour is not specified.

NOTE 2: If the pattern is activated with a message used to perform timing re-initialised hard handover, the UE can start evaluating the activation of the pattern (i.e. compare the value of the CFN in the new configuration with the value of the TGCFN) at any time between the message activation time and the completion of the synchronisation procedure A.

2> if the IE "DPCH compressed mode info" is included in a message used to perform a Hard Handover with change of frequency (see subclause 8.3.5); or

2> if the IE "DPCH compressed mode info" is included in a message used to transfer the UE from Cell_FACH to Cell_DCH, and the cell in which the UE transited from CELL_FACH state is not included in the active set for the CELL_DCH state (see subclause 8.4.1.7.2):

3> not begin the inter-frequency measurement reporting corresponding to the pattern sequence measurement purpose of each activated pattern sequence.

2> else:

3> begin the inter-frequency measurement reporting corresponding to the pattern sequence measurement purpose of each activated pattern sequence.

2> begin the inter-RAT measurement reporting corresponding to the pattern sequence measurement purpose of each activated pattern sequence;

2> if the new configuration is taken into use at the same CFN as indicated by IE "TGCFN":

3> start the concerned pattern sequence immediately at that CFN.

1> monitor if the parallel transmission gap pattern sequences create an illegal overlap, and in case of overlap, take actions as specified in subclause 8.2.11.2.

If the IE "DPCH compressed mode info" is included, and if the IE group "transmission gap pattern sequence configuration parameters" is not included, the UE shall:

1> if, as the result of this message, UE will have more than one transmission gap pattern sequence with the same measurement purpose active (according to IEs "TGMP" and "Current TGPS Status Flag" in variable TGPS_IDENTITY):

2> set the variable CONFIGURATION_INCOMPLETE to TRUE.

1> if there is any pending "TGPS reconfiguration CFN" or any pending "TGCFN":

2> the UE behaviour is unspecified.

1> if pattern sequence corresponding to IE "TGPSI" is already active (according to "Current TGPS Status Flag" in the variable TGPS_IDENTITY):

2> if the "TGPS Status Flag" in this message is set to "deactivate" for the corresponding pattern sequence:

3> deactivate this pattern sequence at the beginning of the frame, indicated by IE "Activation time"(see subclause 8.6.3.1) received in this message, when the new configuration received in this message is taken into use;

3> set the "Current TGPS Status Flag" for this pattern sequence in the variable TGPS_IDENTITY to "inactive" at the frame, indicated by IE "Activation time"(see subclause 8.6.3.1) received in this message, when the new configuration received in this message is taken into use.

2> if the "TGPS Status Flag" in this message is set to "activate" for the corresponding pattern sequence:

3> deactivate this pattern sequence at the beginning of the frame, indicated by IE "Activation time"(see subclause 8.6.3.1) received in this message, when the new configuration received in this message is taken into use.

NOTE 1: The temporary deactivation of pattern sequences for which the status flag is set to "activate" can be used by the network to align the timing of already active patterns with newly activated patterns.

NOTE 2: The deactivation of pattern sequences only occurs as a result of RRC messages received by the UE, i.e. the UE does not set the "Current TGPS Status Flag" to "inactive" after the final gap of a finite length pattern sequence.

1> after the instant in which the message is to be executed, as specified in subclause 8.6.3.1:

2> activate the stored pattern sequence corresponding to each IE "TGPSI" for which the "TGPS status flag" is set to "activate" at the time indicated by IE "TGCFN"; and

NOTE 1: If the pattern is activated with a message that includes the IE "Activation time", and if the CFN value indicated by the IE "Activation Time" and the CFN value indicated by the TGCFN are included in the same TTI (but not at the TTI boundary) common to all the transport channels that are multiplexed onto the reference CCTrCh (as defined in subclause 8.6.3.1), and if the CFN value indicated by the TGCFN is equal or higher than the CFN value indicated by the IE "Activation Time" (as defined in subclause 8.6.3.1) value, the UE behaviour is not specified.

NOTE 2: If the pattern is activated with a message used to perform timing re-initialised hard handover, the UE can start evaluating the activation of the pattern (i.e. compare the value of the CFN in the new configuration with the value of the TGCFN) at any time between the message activation time and the completion of the synchronisation procedure A.

2> set the "Current TGPS Status Flag" for this pattern sequence in the variable TGPS_IDENTITY to "active".

2> if the IE "DPCH compressed mode info" is included in a message used to perform a Hard Handover with change of frequency (see subclause 8.3.5); or

2> if the IE "DPCH compressed mode info" is included in a message used to transfer the UE from Cell_FACH to Cell_DCH, and the cell in which the UE transited from CELL_FACH state is not included in the active set for the CELL_DCH state (see subclause 8.4.1.7.2):

3> not begin the inter-frequency measurement reporting corresponding to the pattern sequence measurement purpose of each activated pattern sequence.

2> else:

3> begin the inter-frequency measurement reporting corresponding to the pattern sequence measurement purpose of each activated pattern sequence.

2> begin the inter-RAT measurement reporting corresponding to the pattern sequence measurement purpose of each activated pattern sequence;

2> if the new configuration is taken into use at the same CFN as indicated by IE "TGCFN":

3> start the concerned pattern sequence immediately at that CFN.

For transmission gap pattern sequences stored in variable TGPS_IDENTITY, but not identified in IE "TGPSI" (either due to the absence of the IE "DPCH compressed mode info" in the received message or due to not receiving the corresponding TGPSI value in the IE "DPCH compressed mode info"), the UE shall:

1> if the received message implies a timing re-initialised hard handover (see subclause 8.3.5.1):

2> deactivate such transmission gap pattern sequences at the beginning of the frame, indicated by IE "Activation time" (see subclause 8.6.3.1) received in this message; and

2> set IE "Current TGPS Status Flag" in corresponding UE variable TGPS_IDENTITY to ‘inactive’.

1> if the received message not implies a timing re-initialised hard handover (see subclause 8.3.5.1):

2> continue such transmission gap pattern sequence according to IE "Current TGPS Status Flag" in the corresponding UE variable TGPS_IDENTITY.

Uplink and downlink compressed mode methods are described in [27]. For UL "higher layer scheduling" compressed mode method and transport format combination selection, see [15].

Reference

3GPP TS 25.331 clause 8.6.6.15.

8.4.1.43.3 Test purpose

To confirm that the UE supports de- activation of compressed mode included in a RADIO BEARER SETUP message.

To confirm that the UE supports reconfiguration of transport channel parameters (rate reduction PS RAB) and change of compressed mode method included in a TRANSPORT CHANNEL RECONFIGURATION message.

To confirm that the UE supports change of compressed mode included in a RADIO BEARER RELEASE message.

To confirm that the UE supports reconfiguration of transport channel parameters (rate increase PS RAB) without performing hard handover included in a TRANSPORT CHANNEL RECONFIGURATION message.

8.4.1.43.4 Method of test

Initial Condition

System Simulator: 3 cells – Cell 1 on frequency f1, cell 4 on frequency f2 and cell 5 on frequency f3.

UE: "CS-DCCH + DTCH_DCH" (state 6-9) as specified in clause 7.4 of TS 34.108.

This test case applies only for UEs requiring compressed mode to perform inter- frequency measurements and supporting both PS and CS domains.

Test Procedure

Table 8.4.1.43-1 illustrates the downlink power to be applied for the 3 cells, as well as the frequency and scrambling code for each cell.

Table 8.4.1.43-1a

Parameter

Unit

Cell 1

Frequency

f1

Scrambling code

Scrambling code 1

T0

T1

T2

T3

T4

T5

CPICH Ec

dBm/3.84 MHz

-60

-70

-70

-60

-70

-70

Table 8.4.1.43-1b

Parameter

Unit

Cell 4

Cell 5

Frequency

f2

f3

Scrambling code

Scrambling code 3

Scrambling code 2

T0

T1

T2

T3

T4

T5

T0

T1

T2

T3

T4

T5

CPICH Ec

dBm/3.84 MHz

-95

-60

-60

-95

-60

-60

-95

-95

-60

-95

-95

-60

The UE is initially in CELL_DCH, and has only cell 1 in its active set.

Next, SS transmits a PHYSICAL CHANNEL RECONFIGURATION message to download compressed mode parameters in the UE without activating compressed mode. The UE shall answer with a PHYSICAL CHANNEL RECONFIGURATION COMPLETE message.

The SS then sets up inter-frequency measurements (event 2b) and activates compressed mode, by sending a MEASUREMENT CONTROL message to the UE.

The SS waits for 2560 ms for the UE to activate compressed mode.

The test operator is prompted to setup a PS call. The SS establishes a PS domain RAB and de-activates compressed mode, by sending a RADIO BEARER SETUP message on DCCH using AM-RLC. The UE shall answer with a RADIO BEARER SETUP COMPLETE message.

At instant T1, the downlink power is changed according to what is shown in table 8.4.1.43-1. The SS shall then verify that the UE does not transmit a MEASUREMENT REPORT message.

Next the SS downloads compressed mode parameters and activates compressed mode (using HLS method) by sending a PHYSICAL CHANNEL RECONFIGURATION message on DCCH using AM-RLC. The UE shall answer with a PHYSICAL CHANNEL RECONFIGURATION COMPLETE message.

Frequency f2 shall then trigger event 2b, and the UE shall transmit a MEASUREMENT REPORT message to the SS.

Next, SS transmits a TRANSPORT CHANNEL RECONFIGURATION message to reconfigure transport channel parameters (rate reduction PS RAB) and to change compressed mode method (to SF/2). The UE shall answer with a TRANSPORT CHANNEL RECONFIGURATION COMPLETE message.

At instant T2, the downlink power is changed according to what is shown in table 8.4.1.43-1. Frequency f3 shall then trigger event 2b, and the UE shall transmit a MEASUREMENT REPORT message to the SS.

At instant T3, the downlink power is changed according to what is shown in table 8.4.1.43-1.The increased quality of the used frequency should result in clearing of the concerning TRIGGERED_2B_EVENT.

Next, SS transmits a RADIO BEARER RELEASE message to release the CS domain RAB and change compressed mode method (from SF/2 to HLS). The UE shall answer with a RADIO BEARER RELEASE COMPLETE message.

At instant T4, the downlink power is changed according to what is shown in table 8.4.1.43-1. Frequency f2 shall then trigger event 2b, and the UE shall transmit a MEASUREMENT REPORT message to the SS.

Next, SS transmits a TRANSPORT CHANNEL RECONFIGURATION message to reconfigure transport channel parameters (rate increase PS RAB) – without performing hard handover. The UE shall answer with a TRANSPORT CHANNEL RECONFIGURATION COMPLETE message.

At instant T5, the downlink power is changed according to what is shown in table 8.4.1.43-1. Frequency f3 shall then trigger event 2b, and the UE shall transmit a MEASUREMENT REPORT message to the SS.

Expected Sequence

Step

Direction

Message

Comment

UE

SS

1

PHYSICAL CHANNEL RECONFIGURATION

SS downloads compressed mode parameters (using SF/2 method) without activating compressed mode.

2

PHYSICAL CHANNEL RECONFIGURATION COMPLETE

The UE acknowledges the downloading of compressed mode parameters.

3

MEASUREMENT CONTROL

The SS configures inter-frequency measurements in the UE and activates compressed mode.

3a

SS waits for 2560 ms.

3b

INITIAL DIRECT TRANSFER

(SERVICE REQUEST)

GMM ( PS session setup is initiated from the UE side).

3c

DOWNLINK DIRECT TRANSFER

(AUTHENTICATION AND CIPHERING REQUEST)

GMM

3d

UPLINK DIRECT TRANSFER

(AUTHENTICATION AND CIPHERING RESPONSE)

GMM

3e

SECURITY MODE COMMAND

3f

SECURITY MODE COMPLETE

3g

UPLINK DIRECT TRANSFER

(ACTIVATE PDP CONTEXT REQUEST)

SM

4

RADIO BEARER SETUP

SS establishes PS domain RAB and de- activates compressed mode.

5

RADIO BEARER SETUP COMPLETE

The UE acknowledges the establishment of the RAB and the de- activation of compressed mode

5a

DOWNLINK DIRECT TRANSFER

(ACTIVATE PDP CONTEXT ACCEPT)

SM

6

The SS changes the power of the cells according to column T1 in table 8.4.1.43-1.

7

SS verifies that the UE does not transmit a MEASUREMENT REPORT message to the SS.

8

PHYSICAL CHANNEL RECONFIGURATION

SS downloads compressed mode parameters (using HLS method) and activates compressed mode.

9

PHYSICAL CHANNEL RECONFIGURATION COMPLETE

The UE acknowledges the downloading of compressed mode parameters and the activation of compressed mode.

10

MEASUREMENT REPORT

Frequency f2 triggers event 2b in the UE, which sends a MEASUREMENT REPORT message to the SS.

11

TRANSPORT CHANNEL RECONFIGURATION

SS reconfigures transport channel parameters (rate reduction PS RAB) and changes compressed mode method to SF/2.

Rate should be reduced to 0 kbps – no PS RAB room left to use for gap.

12

TRANSPORT CHANNEL RECONFIGURATION COMPLETE

The UE acknowledges the transport channel reconfiguration and the change of compressed mode method

13

The SS changes the power of the cells according to column T2 in table 8.4.1.43-1.

14

MEASUREMENT REPORT

Frequency f3 triggers event 2b in the UE, which sends a MEASUREMENT REPORT message to the SS.

15

The SS changes the power of the cells according to T3 in table 8.4.1.43-1 (so the UE can trigger event 2b again for both frequencies).

16

RADIO BEARER RELEASE

SS releases the CS domain RAB and changes compressed mode method to HLS.

17

RADIO BEARER RELEASE COMPLETE

The UE acknowledges the release of the RAB and the compressed mode method change.

18

The SS changes the power of the cells according to column T4 in table 8.4.1.43-1.

19

MEASUREMENT REPORT

Frequency f2 triggers event 2b in the UE, which sends a MEASUREMENT REPORT message to the SS.

20

TRANSPORT CHANNEL RECONFIGURATION

SS reconfigures transport channel parameters (rate increase PS RAB) – without performing hard handover.

21

TRANSPORT CHANNEL RECONFIGURATION COMPLETE

The UE acknowledges the transport channel parameters change.

22

The SS changes the power of the cells according to column T5 in table 8.4.1.43-1.

23

MEASUREMENT REPORT

Frequency f3 triggers event 2b in the UE, which sends a MEASUREMENT REPORT message to the SS.

Specific Message Content

All messages shall use the same content as defined in [9] TS 34.108 clause 9, with the following exceptions:

PHYSICAL CHANNEL RECONFIGURATION MESSAGE (Step 1)

Information Element

Value/Remark

Version

Activation time

Not Present

New U-RNTI

Not Present

New C-RNTI

Not Present

New DSCH-RNTI

Not Present

RRC State indicator

CELL_DCH

UTRAN DRX cycle length coefficient

Not Present

CN information info

Not Present

URA identity

Not Present

Downlink counter synchronisation info

Not Present

Frequency info

Not Present

Maximum allowed UL TX power

Not Present

CHOICE channel requirement

Not Present

CHOICE mode

FDD

– Downlink PDSCH information

Not Present

Downlink information common for all radio links

– Downlink DPCH info common for all RL

Not Present

– DPCH compressed mode info

– TGPSI

1

– TGPS Status Flag

Deactivate

– TGCFN

Not present

– Transmission gap pattern sequence configuration parameters

– TGMP

FDD Measurement

– TGPRC

Infinity

– TGSN

4

– TGL1

7

– TGL2

Not Present

– TGD

undefined

– TGPL1

3

– TGPL2

Not Present

R99 and REL-4 only

– RPP

Mode 0

– ITP

Mode 0

– CHOICE UL/DL Mode

UL and DL, UL only or DL only (depending on the UE capability)

– Downlink compressed mode method

SF/2(or not sent, depending on the UE capability)

– Uplink compressed mode method

SF/2(or not sent, depending on the UE capability)

– Downlink frame type

B

– DeltaSIR1

20 (2.0)

– DeltaSIRAfter1

10 (1.0)

– DeltaSIR2

Not Present

– DeltaSIRAfter2

Not Present

– N identify abort

Not Present

– T Reconfirm abort

Not Present

– TX Diversity mode

Not Present

– SSDT information

Not Present

R99 and Rel-4 only

– Default DPCH Offset Value

Not Present

Downlink information for each radio link

Not Present

MEASUREMENT CONTROL (Step 3)

Information Element

Value/Remark

Measurement Identity

2

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodical Reporting / Event Trigger Reporting Mode

Event Trigger

Additional measurements list

Not Present

CHOICE measurement type

Inter-frequency measurement

– Inter-frequency cell info list

– CHOICE inter-frequency cell removal

No inter-frequency cells removed

– New inter-frequency info list

2 inter-frequency cells

– Inter-frequency cell id

4

– Frequency info

– UARFCN uplink (Nu)

Not present

Absence of this IE is equivalent to applying the default duplex distance defined for the operating frequency according to 3GPP TS 25.101 [21]

– UARFCN downlink (Nd)

UARFCN for the downlink corresponding to f2

– Cell info

– Cell individual offset

0 dB

– Reference time difference to cell

Not present

– Read SFN Indicator

FALSE

– CHOICE Mode

FDD

– Primary CPICH Info

– Primary Scrambling Code

Scrambling code 3

– Primary CPICH TX power

Not Present

– TX Diversity Indicator

FALSE

– Inter-frequency cell id

5

– Frequency info

– UARFCN uplink (Nu)

Not present

Absence of this IE is equivalent to applying the default duplex distance defined for the operating frequency according to 3GPP TS 25.101 [21]

– UARFCN downlink (Nd)

UARFCN for the downlink corresponding to f3

– Cell info

– Cell individual offset

0 dB

– Reference time difference to cell

Not present

– Read SFN Indicator

FALSE

– CHOICE Mode

FDD

– Primary CPICH Info

Not present

– Primary Scrambling Code

Scrambling code 2

– Primary CPICH TX power

Not Present

– TX Diversity Indicator

FALSE

– Cells for measurement

Not present

– Inter-frequency measurement quantity

– CHOICE reporting criteria

Inter-frequency reporting criteria

– Filter Coefficient

0

– Measurement quantity for frequency quality estimate

CPICH RSCP

– Inter-frequency reporting quantity

– UTRA Carrier RSSI

FALSE

– Frequency quality estimate

FALSE

– Non frequency related cell reporting quantities

– SFN-SFN observed time difference reporting indicator

No report

– Cell synchronisation information reporting indicator

FALSE

– Cell Identity reporting indicator

TRUE

– CPICH Ec/No reporting indicator

FALSE

– CPICH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting cell status

Not present

– Measurement validity

– UE State

CELL_DCH

– Inter-frequency set update

– UE autonomous update

On with no reporting

– Non autonomous update mode

Not present

– CHOICE report criteria

Inter-frequency measurement reporting criteria

– Parameters required for each event

– Inter-frequency event identity

2b

– Threshold used frequency

-70 dBm

– W used frequency

0.0

– Hysteresis

2 (1 dB)

– Time to trigger

100 ms

– Reporting cell status

Report cells within monitored and/or virtual active set on non-used frequency

– Maximum number of reported cells per
reported non-used frequency

2

Parameters required for each non-used
frequency

– Threshold non used frequency

-65 dBm

– W non-used frequency

0

DPCH compressed mode status info

– TGPS reconfiguration CFN

(Current CFN + (256 – TTI/10msec))mod 256

– Transmission gap pattern sequence

– TGPSI

1

– TGPS Status Flag

Activate

– TGCFN

(Current CFN + (256 – TTI/10msec))mod 256

RADIO BEARER SETUP (Step 4)

Use the same message sub-type found in TS 34.108 clause 9, which is entitled " Packet RAB Setup after Speech RAB Setup in CELL_DCH ", with the following modifications:

Information Element

Value/Remark

– DPCH compressed mode info

– TGPSI

1

– TGPS Status Flag

De-activate

– TGCFN

Not present

PHYSICAL CHANNEL RECONFIGURATION MESSAGE (Step 8)

Information Element

Value/Remark

Version

Activation time

Not Present

New U-RNTI

Not Present

New C-RNTI

Not Present

New DSCH-RNTI

Not Present

RRC State indicator

CELL_DCH

UTRAN DRX cycle length coefficient

Not Present

CN information info

Not Present

URA identity

Not Present

Downlink counter synchronisation info

Not Present

Frequency info

Not Present

Maximum allowed UL TX power

Not Present

CHOICE channel requirement

Not Present

CHOICE mode

FDD

– Downlink PDSCH information

Not Present

Downlink information common for all radio links

– Downlink DPCH info common for all RL

Not Present

– DPCH compressed mode info

– TGPSI

1

– TGPS Status Flag

Activate

– TGCFN

(Current CFN + (256 – TTI/10msec))mod 256

– Transmission gap pattern sequence configuration parameters

– TGMP

FDD Measurement

– TGPRC

Infinity

– TGSN

4

– TGL1

7

– TGL2

Not Present

– TGD

undefined

– TGPL1

3

– TGPL2

Not Present

R99 and REL-4 only

– RPP

Mode 0

– ITP

Mode 0

– CHOICE UL/DL Mode

UL and DL, UL only or DL only (depending on the UE capability)

– Downlink compressed mode method

HLS(or not sent, depending on the UE capability)

– Uplink compressed mode method

HLS(or not sent, depending on the UE capability)

– Downlink frame type

B

– DeltaSIR1

20 (2.0)

– DeltaSIRAfter1

10 (1.0)

– DeltaSIR2

Not Present

– DeltaSIRAfter2

Not Present

– N identify abort

Not Present

– T Reconfirm abort

Not Present

– TX Diversity mode

Not Present

– SSDT information

Not Present

R99 and Rel-4 only

– Default DPCH Offset Value

Not Present

Downlink information for each radio link

Not Present

MEASUREMENT REPORT (Step 10,19)

Information Element

Value/Remark

Message Type

Integrity check info

– Message authentication code

This IE is checked to see if it is present. The value is compared against the XMAC-I value computed by SS. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I.

– RRC Message sequence number

This IE is checked to see if it is present. The value is used by SS to compute the XMAC-I value.

Measurement identity

2

Measured Results

– Inter-frequency measured results list

– Frequency info

-CHOICE mode

FDD

– UARFCN uplink

The presence of this IE is not checked

– UARFCN downlink

Check that the value of this IE is set to UARFCN for the downlink corresponding to f2

– UTRA carrier RSSI

Check that this IE is absent

– Inter-frequency cell measurement results

Check that the value of this IE is set to 1 cell reported

– Cell measured results

– Cell Identity

Check that this IE is absent

– SFN-SFN observed time difference

Check that this IE is absent

– Cell synchronisation information

Check that this IE is absent

– Primary CPICH info

– Primary scrambling code

Check that the value of this IE is set to Scrambling code 3

– CPICH Ec/N0

Check that this IE is absent

– CPICH RSCP

Check that this IE is present

– Pathloss

Check that this IE is absent

Measured results on RACH

Check that this IE is absent

Additional measured results

Check that this IE is absent

Event results

– Inter-frequency measurement event results

– Inter-frequency event identity

2b

– Inter-frequency cells

– Frequency info

-CHOICE mode

FDD

– UARFCN uplink

The presence of this IE is not checked

– UARFCN downlink

Check that the value of this IE is set to UARFCN for the downlink corresponding to f2

– Non freq related measurement event results

– Primary CPICH info

– Primary scrambling code

Check that the value of this IE is set to Scrambling code 3

TRANSPORT CHANNEL RECONFIGURATION (Step 11)

The contents of TRANSPORT CHANNEL RECONFIGURATION message in this test case is identical to the message sub-type titled "Packet to CELL_DCH from CELL_DCH in PS" in 34.108 [9], with the following exceptions:

Information Element

Value/remark

Version

UL Transport channel information for all transport channels

Do not include TFCs with TF’s other than TF0 for PS RAB

Added or Reconfigured UL TrCH information

Reconfigure PS RAB TFS, only include TF0 and UL Transport channel identity as 4

DL Transport channel information common for all transport channel

Do not include TFCs with TF’s other than TF0 for PS RAB

Added or Reconfigured DL TrCH information

Reconfigure PS RAB TFS, only include TF0 and DL Transport channel identity as 9

Frequency info

Not Present

Maximum allowed UL TX power

Not Present

Downlink information common for all radio links

– DPCH compressed mode info

– TGPSI

1

– TGPS Status Flag

Activate

– TGCFN

(Current CFN + (256 – TTI/10msec))mod 256

– Transmission gap pattern sequence configuration parameters

– TGMP

FDD Measurement

– TGPRC

Infinity

– TGSN

4

– TGL1

7

– TGL2

Not Present

– TGD

undefined

– TGPL1

3

– TGPL2

Not Present

R99 and REL-4 only

– RPP

Mode 0

– ITP

Mode 0

– CHOICE UL/DL Mode

UL and DL, UL only or DL only (depending on the UE capability)

– Downlink compressed mode method

SF/2(or not sent, depending on the UE capability)

– Uplink compressed mode method

SF/2(or not sent, depending on the UE capability)

– Downlink frame type

B

– DeltaSIR1

20 (2.0)

– DeltaSIRAfter1

10 (1.0)

– DeltaSIR2

Not Present

– DeltaSIRAfter2

Not Present

– N identify abort

Not Present

– T Reconfirm abort

Not Present

– TX Diversity mode

Not Present

– SSDT information

Not Present

R99 and Rel-4 only

– Default DPCH Offset Value

Not Present

MEASUREMENT REPORT (Step 14,23)

NOTE: Due to ambiguity in 25.331 clause 14.2.1.2 – two interpretations can be given for MEASUREMENT REPORT

Information Element

Value/Remark

Message Type

Integrity check info

– Message authentication code

This IE is checked to see if it is present. The value is compared against the XMAC-I value computed by SS. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I.

– RRC Message sequence number

This IE is checked to see if it is present. The value is used by SS to compute the XMAC-I value.

Measurement identity

2

Measured Results

– Inter-frequency measured results list

– Frequency info

-CHOICE mode

FDD

– UARFCN uplink

Check that the value of this IE is set to UARFCN for the uplink corresponding to f3 (Could be absent in case the duplex distance is the default duplex distance)

– UARFCN downlink

Check that the value of this IE is set to UARFCN for the downlink corresponding to f3

– UTRA carrier RSSI

Check that this IE is absent

– Inter-frequency cell measurement results

Check that the value of this IE is set to 1 cell reported

– Cell measured results

– Cell Identity

Check that this IE is absent

– SFN-SFN observed time difference

Check that this IE is absent

– Cell synchronisation information

Check that this IE is absent

– Primary CPICH info

– Primary scrambling code

Check that the value of this IE is set to Scrambling code 2 (on f3)

– CPICH Ec/N0

Check that this IE is absent

– CPICH RSCP

Check that this IE is present

– Pathloss

Check that this IE is absent

Measured results on RACH

Check that this IE is absent

Additional measured results

Check that this IE is absent

Event results

– Inter-frequency measurement event results

– Inter-frequency event identity

2b

– Inter-frequency cells

– Frequency info

-CHOICE mode

FDD

– UARFCN uplink

Check that the value of this IE is set to UARFCN for the uplink corresponding to f3 (Could be absent in case the duplex distance is the default duplex distance)

– UARFCN downlink

Check that the value of this IE is set to UARFCN for the downlink corresponding to f3

– Non freq related measurement event results

– Primary CPICH info

– Primary scrambling code

Check that the value of this IE is set Scrambling code 2 (on f3)

OR:

Information Element

Value/Remark

Message Type

Integrity check info

– Message authentication code

This IE is checked to see if it is present. The value is compared against the XMAC-I value computed by SS. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I.

– RRC Message sequence number

This IE is checked to see if it is present. The value is used by SS to compute the XMAC-I value.

Measurement identity

2

Measured Results

– Inter-frequency measured results list

– Frequency info

-CHOICE mode

FDD

– UARFCN uplink

The presence of this IE is not checked

– UARFCN downlink

Check that the value of this IE is set to UARFCN for the downlink corresponding to f2 or f3

– UTRA carrier RSSI

Check that this IE is absent

– Inter-frequency cell measurement results

Check that the value of this IE is set to 1 cell reported

– Cell measured results

– Cell Identity

Check that this IE is absent

– SFN-SFN observed time difference

Check that this IE is absent

– Cell synchronisation information

Check that this IE is absent

– Primary CPICH info

– Primary scrambling code

Check that the value of this IE is set to Scrambling code 3 (on f2) or Scrambling code 2 (on f3)

– CPICH Ec/N0

Check that this IE is absent

– CPICH RSCP

Check that this IE is present

– Pathloss

Check that this IE is absent

– Frequency info

-CHOICE mode

FDD

– UARFCN uplink

The presence of this IE is not checked

– UARFCN downlink

Check that the value of this IE is set to UARFCN for the downlink corresponding to f2 or f3

– UTRA carrier RSSI

Check that this IE is absent

– Inter-frequency cell measurement results

Check that the value of this IE is set to 1 cell reported

– Cell measured results

– Cell Identity

Check that this IE is absent

– SFN-SFN observed time difference

Check that this IE is absent

– Cell synchronisation information

Check that this IE is absent

– Primary CPICH info

– Primary scrambling code

Check that the value of this IE is set to Scrambling code 3 (on f2) or Scrambling code 2 (on f3)

– CPICH Ec/N0

Check that this IE is absent

– CPICH RSCP

Check that this IE is present

– Pathloss

Check that this IE is absent

Measured results on RACH

Check that this IE is absent

Additional measured results

Check that this IE is absent

Event results

– Inter-frequency measurement event results

– Inter-frequency event identity

2b

– Inter-frequency cells

– Frequency info

-CHOICE mode

FDD

– UARFCN uplink

The presence of this IE is not checked

– UARFCN downlink

Check that the value of this IE is set to UARFCN for the downlink corresponding to f2 or f3

– Non freq related measurement event results

– Primary CPICH info

– Primary scrambling code

Check that the value of this IE is set to Scrambling code 3 (on f2) or Scrambling code 2 (on f3)

– Frequency info

-CHOICE mode

FDD

– UARFCN uplink

The presence of this IE is not checked

– UARFCN downlink

Check that the value of this IE is set to UARFCN for the downlink corresponding to f2 or f3

– Non freq related measurement event results

– Primary CPICH info

– Primary scrambling code

Check that the value of this IE is set to Scrambling code 3 (on f2) or Scrambling code 2 (on f3)

RADIO BEARER RELEASE (Step 16)

Use the same message sub-type found in TS 34.108 clause 9, which is entitled "Non speech in CS" or "Speech in CS", with the following modifications:

Information Element

Value/Remark

Version

Added or Reconfigured UL TrCH information

– Uplink transport channel type

DCH

– UL Transport channel identity

4

– TFS

– CHOICE Transport channel type

Dedicated transport channels

– Dynamic Transport format information

– RLC Size

Reference to 6.11.4b in TS34.108

– Number of TBs and TTI List

(This IE is repeated for TFI number.)

– Transmission Time Interval

Not Present

– Number of Transport blocks

Reference to 6.11.4b in TS34.108

– CHOICE Logical channel list

All

– Semi-static Transport Format information

– Transmission time interval

Reference to 6.11.4b in TS34.108

– Type of channel coding

Reference to 6.11.4b in TS34.108

– Coding Rate

Reference to 6.11.4b in TS34.108

– Rate matching attribute

Reference to 6.11.4b in TS34.108

– CRC size

Reference to 6.11.4b in TS34.108

Added or Reconfigured DL TrCH information

– Downlink transport channel type

DCH

– DL Transport channel identity

9

– CHOICE DL parameters

Same as UL

– Uplink transport channel type

DCH

– UL TrCH identity

4

– DCH quality target

– BLER Quality value

Not Present

CHOICE channel requirement

– Uplink DPCH power control info

Uplink DPCH info

– DPCCH power offset

-40 (-80dB)

– PC Preamble

1 frame

– SRB delay

7 frames

– Power Control Algorithm

Algorithm1

– ACK

Not Present

– NACK

Not Present

– Ack-Nack repetition factor

Not Present

– TPC step size

0 (1dB)

– Scrambling code type

Long

– Scrambling code number

0 (0 to 16777215)

– Number of DPDCH

Not Present(1)

– spreading factor

Reference to 6.11.4b in TS34.108

– TFCI existence

Reference to 6.11.4b in TS34.108

– Number of FBI bit

Reference to 6.11.4b in TS34.108

– Puncturing Limit

Reference to 6.11.4b in TS34.108

Downlink information common for all radio links

– Downlink DPCH info common for all RL

– Timing indicator

Maintain

– CFN-targetSFN frame offset

Not Present

– Downlink DPCH power control information

– DPC mode

0 (single)

– CHOICE mode

FDD

– Power offset PPilot-DPDCH

0

– DL rate matching restriction information

Not Present

– Spreading factor

Reference to 6.11.4b in TS34.108

– Fixed or Flexible Position

Reference to 6.11.4b in TS34.108

– TFCI existence

Reference to 6.11.4b in TS34.108

– CHOICE SF

Reference to 6.11.4b in TS34.108

– DPCH compressed mode info

– TGPSI

1

– TGPS Status Flag

Activate

– TGCFN

(Current CFN + (256 – TTI/10msec))mod 256

– Transmission gap pattern sequence configuration parameters

– TGMP

FDD Measurement

– TGPRC

Infinity

– TGSN

4

– TGL1

7

– TGL2

Not Present

– TGD

undefined

– TGPL1

3

– TGPL2

Not Present

R99 and REL-4 only

– RPP

Mode 0

– ITP

Mode 0

– CHOICE UL/DL Mode

UL and DL, UL only or DL only (depending on the UE capability)

– Downlink compressed mode method

HLS(or not sent, depending on the UE capability)

– Uplink compressed mode method

HLS(or not sent, depending on the UE capability)

– Downlink frame type

B

– DeltaSIR1

20 (2.0)

– DeltaSIRAfter1

10 (1.0)

– DeltaSIR2

Not Present

– DeltaSIRAfter2

Not Present

– N identify abort

Not Present

– T Reconfirm abort

Not Present

TRANSPORT CHANNEL RECONFIGURATION (Step 20)

The content of the TRANSPORT CHANNEL RECONFIGURATION message at this step is identical to the message sub-type titled "Packet to CELL_DCH from CELL_DCH in PS" in 34.108 [9].

8.4.1.43.5 Test Requirement

After step 1, the UE shall send a PHYSICAL CHANNEL RECONFIGURATION COMPLETE message to the SS to acknowledge the downloading of the compressed mode parameters without activating compressed mode that were included in the PHYSICAL CHANNEL RECONFIGURATION message of step 1.

After step 4, the UE shall send a RADIO BEARER SETUP COMPLETE message to acknowledge the establishment of the PS domain RAB and the de- activation of compressed mode that were included in the RADIO BEARER SETUP message of step 4.

After step 6, the UE shall not transmit a MEASUREMENT REPORT message.

After step 8, the UE shall send a PHYSICAL CHANNEL RECONFIGURATION COMPLETE message to the SS to acknowledge the downloading of the compressed mode parameters and the activation of compressed mode that were included in the PHYSICAL CHANNEL RECONFIGURATION message of step 8.

After step 9, the UE shall transmit a MEASUREMENT REPORT message triggered by frequency f2. That message shall only include cell 4 within the IE event results.

After step 11, the UE shall transmit a TRANSPORT CHANNEL RECONFIGURATION COMPLETE message to the SS to acknowledge the change of transport channel parameters and the change of compressed mode method that were included in the TRANSPORT CHANNEL RECONFIGURATION message of step 11.

After step 13, the UE shall transmit a MEASUREMENT REPORT message triggered by frequency f3.

After step 17, the UE shall transmit a RADIO BEARER RELEASE COMPLETE message to the SS to acknowledge the release of the RAB and the change of compressed mode method that were included in the RADIO BEARER RELEASE message of step 17.

After step 18, the UE shall transmit a MEASUREMENT REPORT message triggered by frequency f2. That message shall only include cell 4 within the IE event results.

After step 20, the UE shall transmit a TRANSPORT CHANNEL RECONFIGURATION COMPLETE message to the SS to acknowledge the change of transport channel parameters that were included in the TRANSPORT CHANNEL RECONFIGURATION message of step 20.

After step 22, the UE shall transmit a MEASUREMENT REPORT message triggered by frequency f3.

8.4.1.44 Measurement Control and Report: Intra-frequency measurement for events 1H and 1I (TDD)

8.4.1.44.1 Definition

8.4.1.44.2 Conformance requirement

When event 1h is configured in the UE, the UE shall:

1> if equation 1 is fulfilled for a time period indicated by "Time to trigger" and if that P-CCPCH is not included in the IE "cells triggered" in the variable TRIGGERED_1H_EVENT:

2> include that P-CCPCH in the IE "cells triggered" in the variable TRIGGERED_1H_EVENT;

2> send a measurement report with the IEs set as below:

3> set in "intra-frequency measurement event results": "Intrafrequency event identity" to "1h" and in "cell measurement event results" the "Cell parameters ID" of the P-CCPCH that triggered the report;

3> include in "Cell measured results" the "Timeslot ISCP" of those cells that are included in the variable TRIGGERED_1H_EVENT.

1> if a primary CCPCH is included in the "cells triggered" in the variable TRIGGERED_1H_EVENT:

2> send a measurement report with IEs set as below:

3> set in "intra-frequency measurement event results": "Intrafrequency event identity" to "1h" and "cell measurement event results" to the "Cell parameters ID" of the P-CCPCH that triggered the report;

3> set in "measured results " the "Timeslot ISCP" of those cells that are included in the variable TRIGGERED_1H_EVENT and "additional measured results" according to subclause 8.4.2 in TS 25.331, not taking into account the cell individual offset for each cell.

1> if Equation 2 below is fulfilled for a primary CCPCH:

2> if a primary CCPCH is included in the "cells triggered" in the variable TRIGGERED_1H_EVENT:

3> remove the entry of that primary CCPCH from "cells triggered" in the variable TRIGGERED_1H_EVENT.

The UE shall use the equations below for evaluation of reporting event 1h:

Equation 1

Equation 2

The variables in the formula are defined as follows:

Mi is the Timeslot ISCP of the currently evaluated cell i expressed in mW

Oi is the cell individual offset of the currently evaluated cell i

T1h is the Threshold for event 1h

H1h is the hysteresis parameter for the event 1h.

Before any evaluation is done, the Timeslot ISCP expressed in mW is filtered according to subclause 8.6.7.2. in TS 25.331

When event 1i is configured in the UE, the UE shall:

1> if equation 1 is fulfilled for a time period indicated by "Time to trigger" and if that P-CCPCH is not included in the IE "cells triggered" in the variable TRIGGERED_1I_EVENT:

2> include that P-CCPCH in the IE "cells triggered" in the variable TRIGGERED_1I_EVENT;

2> send a measurement report with the IEs set as below:

3> set in "intra-frequency measurement event results": "Intrafrequency event identity" to "1i" and in "cell measurement event results" to the "Cell parameters ID" of the P-CCPCH that triggered the report;

3> include in "measured results" the "Timeslot ISCP" of those cells that are included in the variable TRIGGERED_1I_EVENT and "additional measured results" according to 8.4.2 in TS 25.331, not taking into account the cell individual offset for each cell.

1> if a primary CCPCH is included in the "cells triggered" in the variable TRIGGERED_1I_EVENT:

2> if Equation 2 below is fulfilled for a primary CCPCH:

3> if a primary CCPCH is included in the "cells triggered" in the variable TRIGGERED_1I_EVENT:

4> remove the entry of that primary CCPCH from "cells triggered" in the variable TRIGGERED_1I_EVENT.

The UE shall use the equation below for evaluation of reporting event 1i:

Equation 1

Equation 2

The variables in the formula are defined as follows:

Mi is the Timeslot ISCP of the currently evaluated cell i expressed in mW

Oi is the cell individual offset of the currently evaluated cell i

T1i is the Threshold for event 1i

H1i is the hysteresis parameter for the event 1i.

Before any evaluation is done, the Timeslot ISCP expressed in mW is filtered according to subclause 8.6.7.2. in TS 25.331

Reference

3GPP TS 25.331 clause 14.1.3.2, 14.1.3.3.

8.4.1.44.3 Test Purpose

1. To confirm that the UE sends MEASUREMENT REPORT message if event 1I is configured and intra-frequency measurement indicates that Timeslot ISCP is above a certain threshold

2. To confirm that the UE sends MEASUREMENT REPORT message if event 1H is configured, and intra-frequency measurement indicates that Timeslot ISCP is below a certain threshold

8.4.1.44.4 Method of test

8.4.1.44.4.1 3.84 Mcps option

<FFS>

8.4.1.44.4.2 1.28 Mcps option

Initial Condition

System Simulator: 1 cell – The initial configurations of the cell in the SS shall follow the values indicated in the column marked "T1" in table 8.4.1.44.4.2-1. Threshold for events 1H and 1I are specified in table 8.4.1.44.4.2-2

UE: CS-DCCH+DTCH_DCH (State 6-9) or PS-DCCH+DTCH_DCH (State 6-10) in cell 1 as specified in clause 7.4 of TS 34.108, depending on the CN domain supported by the UE.

The test consists of four successive time periods, with a time duration of T1, T2, T3 and T4 respectively. Two cells shall be present in the test, being cell 1 the current serving cell. Timeslot ISCP values are specified for the cell, to check against a certain threshold.

Test Procedure

Table 8.4.1.44.4.2-1 illustrates the Cell 1 specific test parameters for correct event 1H and 1I reporting in AWGN propagation condition. The other RF values needed for the test are referred to section 8 in TS 34.122

Column marked "T1" denotes the initial conditions, while columns marked "T2", "T3" and "T4" are to be applied subsequently. The exact instants on which these values shall be applied are described in the text below.

Table 8.4.1.44.4.2-1

Parameter

Unit

Cell 1

T1

T2

T3

T4

UTRA RF Channel Number

Channel 1

DL timeslot number

6

PCCPCH RSCP

dBm

n.a.

TS ISCP, Note 1

-74

-64

-74

-64

dBm / 1.28 MHz

-70

NOTE 1: The TS ISCP level is a calculated value.

Table 8.4.1.44.4.2-2

Parameter

Unit

Value

Comment

Threshold used frequency

dBm

-69

Applicable for event 1H, cell 1 timeslot 6

Threshold used frequency

dBm

-69

Applicable for event 1I, cell 1 timeslot 6

The UE is initially in CELL_DCH state of cell 1. System Information Block type 11 is configured according to allow measurement for intra-frequency, 1 Cell is defined and Timeslot 6 is defined for measurements. SS then sends MEASUREMENT CONTROL message to the UE to modify earlier configured intra-frequency measurement and a primary CCPCH is included in the "cells triggered" in the variable TRIGGERED_1I_EVENT and TRIGGERED_1H_EVENT.

UE shall report TRIGGERED_1H_EVENT or TRIGGERED_1I_EVENT in the different time periods during the test. SS re-adjusts the downlink transmission power settings according to columns "T2", "T3" and "T4" successively in table 8.4.1.44.4.2-1

SS calls for generic procedure C.3 to check that UE is in CELL_DCH state.

Expected Sequence

Step

Direction

Message

Comment

UE

SS

1

System Information Block type 11

The UE is in CELL_DCH and camped onto cell 1. The System Information Block type 11 messages to be transmitted are different from the default settings

2

MEASUREMENT CONTROL

Event 1I and 1H are configured. IEs and threshold values are included

3

MEASUREMENT REPORT

Event 1H is triggered. The UE shall report that for cell 1 timeslot 6, ISCP is below than threshold

4

SS re-adjusts the downlink transmission power settings according to columns "T2" in table 8.4.1.44.4.2-1.

5

MEASUREMENT REPORT

Event 1I is triggered. The UE shall report that for cell 1 timeslot 6 ISCP is above threshold

6

SS re-adjusts the downlink transmission power settings according to columns "T3" in table 8.4.1.44.4.2-1.

7

MEASUREMENT REPORT

Event 1H is triggered. The UE shall report that for cell 1 timeslot 6, ISCP is below than threshold

8

SS re-adjusts the downlink transmission power settings according to columns "T4" in table 8.4.1.44.4.2-1.

9

MEASUREMENT REPORT

Event 1I is triggered. The UE shall report that for cell 1 timeslot 6 ISCP is above threshold

10



CALL C.3

If the test result of C.3 indicates that UE is in CELL_DCH state, the test passes, otherwise it fails

Specific Message Contents

All messages indicated below shall use the same content as described in default message content, with the following exceptions.

System Information Block type 11 (Step 1)

Information Element

Value/remark

SIB12 indicator

FALSE

FACH measurement occasion info

Not Present

Measurement control system information

– Use of HCS

Not used

– Cell selection and reselection quality measure

CPICH RSCP

– Intra-frequency measurement system information

– Intra-frequency measurement identity

Not Present

Absence of this IE is equivalent to default value 1

– Intra-frequency cell info list

– CHOICE intra-frequency cell removal

Not present

(This IE shall be ignored by the UE for SIB11)

– New intra-frequency cells

– Intra-frequency cell id

1

– Cell info

– Cell individual offset

Not present

Absence of this IE is equivalent to default value 0 dB

– Reference time difference to cell

Not Present

– Read SFN Indicator

FALSE

– CHOICE Mode

TDD

– Primary CCPCH Info

Refer to clause titled "Default settings for cell No.1 (TDD)" in clause 6.1.4 of TS 34.108

– Primary CCPCH TX Power

Not present

– Timeslot List

– Timeslot Number

6

– Burst Type

Type 1

– Cell selection and Re-selection

Not Present (The IE shall be absent as this is the serving cell)

– Intra-frequency measurement quantity

Not present

– Intra-frequency measurement for RACH reporting

Not Present

– Maximum number of reported cells on RACH

Not Present

– Reporting information for state CELL_DCH

Not Present

– Inter-frequency measurement system information

Not present

– Inter-RAT measurement system information

Not Present

– Traffic volume measurement system information

Not Present

MEASUREMENT CONTROL (Step 2)

Information Element

Value/remark

Measurement Identity

1

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Event Trigger

Additional measurements list

Not Present

CHOICE measurement type

Intra-frequency measurement

– Intra-frequency cell info list

Not present

– Intra-frequency measurement quantity

– Filter Coefficient

0

– CHOICE Mode

TDD

– Measurement quantity

PCCPCH RSCP

– Intra-frequency reporting quantity

– Reporting quantities for active set cells

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– Timeslot ISCP reporting indicator

TRUE

– Proposed TGSN reporting indicator

FALSE

– PCCPCH RSCP reporting indicator

FALSE

– Pathloss reporting indicator

FALSE

– Reporting quantities for monitored set cells

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– Timeslot ISCP reporting indicator

FALSE

– Proposed TGSN reporting indicator

FALSE

– PCCPCH RSCP reporting indicator

FALSE

– Pathloss reporting indicator

FALSE

– Measurement validity

Not present

– CHOICE report criteria

Intra-frequency measurement reporting criteria

– Parameters required for each events

– Intra-frequency event identity

1h

– Threshold used frequency

-69 dB

– Hysteresis

0 (0 dB)

– Time to Trigger

0

– Intra-frequency event identity

1i

– Threshold used frequency

-69 dB

– Hysteresis

0 (0 dB)

– Time to Trigger

0

MEASUREMENT REPORT (Step 3)

Information Element

Value/remark

Measurement identity

Check to see if set to 1

Measured Results

– CHOICE measurement

Check to see if set to "Intra-frequency measured results list"

– Cell measured results

– Cell Identity

Check to see if it is absent

– Cell synchronisation information

Check to see if this IE is absent

– Cell parameters ID

Check to see if it’s the same for cell 1

– PCCPCH RSCP

Check to see if this IE is absent

– Pathloss

Check to see if this IE is absent

– Timeslot ISCP

Check to see if this IE is present

Measured Results on RACH

Check to see if this IE is absent

Additional Measured Results

Check to see if this IE is absent

Event Results

– CHOICE event result

Check to see if this IE is set to "Intra-frequency measurement event results"

– Intra-frequency event identity

Check to see if this IE is set to "1H"

MEASUREMENT REPORT (Step 5)

Information Element

Value/remark

Measurement identity

Check to see if set to 1

Measured Results

– CHOICE measurement

Check to see if set to "Intra-frequency measured results list"

– Cell measured results

– Cell Identity

Check to see if it is absent

– Cell synchronisation information

Check to see if this IE is absent

– Cell parameters ID

Check to see if it’s the same for cell 1

– PCCPCH RSCP

Check to see if this IE is absent

– Pathloss

Check to see if this IE is absent

– Timeslot ISCP

Check to see if this IE is present

Measured Results on RACH

Check to see if this IE is absent

Additional Measured Results

Check to see if this IE is absent

Event Results

– CHOICE event result

Check to see if this IE is set to "Intra-frequency measurement event results"

– Intra-frequency event identity

Check to see if this IE is set to "1I"

MEASUREMENT REPORT (Step 7)

Information Element

Value/remark

Measurement identity

Check to see if set to 1

Measured Results

– CHOICE measurement

Check to see if set to "Intra-frequency measured results list"

– Cell measured results

– Cell Identity

Check to see if it is absent

– Cell synchronisation information

Check to see if this IE is absent

– Cell parameters ID

Check to see if it’s the same for cell 1

– PCCPCH RSCP

Check to see if this IE is absent

– Pathloss

Check to see if this IE is absent

– Timeslot ISCP

Check to see if this IE is present

Measured Results on RACH

Check to see if this IE is absent

Additional Measured Results

Check to see if this IE is absent

Event Results

– CHOICE event result

Check to see if this IE is set to "Intra-frequency measurement event results"

– Intra-frequency event identity

Check to see if this IE is set to "1H"

MEASUREMENT REPORT (Step 9)

Information Element

Value/remark

Measurement identity

Check to see if set to 1

Measured Results

– CHOICE measurement

Check to see if set to "Intra-frequency measured results list"

– Cell measured results

– Cell Identity

Check to see if it is absent

– Cell synchronisation information

Check to see if this IE is absent

– Cell parameters ID

Check to see if it’s the same for cell 1

– PCCPCH RSCP

Check to see if this IE is absent

– Pathloss

Check to see if this IE is absent

– Timeslot ISCP

Check to see if this IE is present

Measured Results on RACH

Check to see if this IE is absent

Additional Measured Results

Check to see if this IE is absent

Event Results

– CHOICE event result

Check to see if this IE is set to "Intra-frequency measurement event results"

– Intra-frequency event identity

Check to see if this IE is set to "1I"

8.4.1.44.5 Test Requirement

The UE shall send one event 1H triggered measurement report, with a measurement reporting delay less than 400 ms from the beginning of time period T2.

The UE shall send one event 1I triggered measurement report, with a measurement reporting delay less than 400 ms from the beginning of time period T3.

The UE shall send one event 1H triggered measurement report, with a measurement reporting delay less than 400 ms from the beginning of time period T4.

The UE shall not send event 1H or 1I triggered measurement reports, as long as the reporting criteria are not fulfilled.

8.4.1.45 Measurement Control and Report: Intra-frequency measurement for event 1G (TDD)

8.4.1.45.1 Definition

8.4.1.45.2 Conformance requirement

When event 1G is configured in the UE, the UE shall:

1> if the equation 1 is fulfilled for a P-CCPCHs during the time "Time to trigger" and if that P-CCPCH is not included in the "primary CCPCH info" in the variable TRIGGERED_1G_EVENT:

2> include that P-CCPCH in "cells triggered" in the variable TRIGGERED_1G_EVENT;

2> send a measurement report with IEs set as below:

3> set in "intra-frequency measurement event results": "Intrafrequency event identity" to "1g";

3> set the first entry in "cell measurement event results" to the "Cell parameters ID" of the P-CCPCH which was stored in the variable TRIGGERED_1G_EVENT;

3> include all entries in "cells triggered" in variable TRIGGERED_1G_EVENT in "cell measurement event results" in the measurement report in descending order according to:

where M is the P-CCPCH RSCP and O the individual offset of a cell;

3> set the IE "measured results" and the IE "additional measured results" according to subclause 8.4.2, not taking into account the cell individual offset for each cell.

1> if Equation 2 below is fulfilled for a primary CCPCH:

2> if a primary CCPCH is included in the "cells triggered" in the variable TRIGGERED_1G_EVENT:

3> remove the entry of that primary CCPCH from "cells triggered" in the variable TRIGGERED_1G_EVENT;

The UE shall use the equations below for evaluation of reporting event 1g:

Equation 1

The variables in the formula are defined as follows:

Mprevious_best is the current P-CCPCH RSCP of the previous best cell expressed in mW

Oprevious_best is the cell individual offset of the previous best cell

Mi is the current P-CCPCH RSCP of the currently evaluated cell i expressed in mW

Oi is the cell individual offset of the currently evaluated cell i

H1g is the hysteresis parameter for the event 1g.

Equation 2

The variables in the formula are defined as follows:

Mprevious_best is the current P-CCPCH RSCP of the previous best cell expressed in mW

Oprevious_best is the cell individual offset of the previous best cell

Mi is the current P-CCPCH RSCP of the currently evaluated cell i expressed in mW

Oi is the cell individual offset of the currently evaluated cell i

H1g is the hysteresis parameter for the event 1g.

Reference

3GPP TS 25.331, clauses 14.1.3.1

8.4.1.45.3 Test Purpose

1. To confirm that the UE sends MEASUREMENT REPORT message if event 1G is configured and intra-frequency measurement indicates change of best cell.

8.4.1.45.4 Method of test

Initial Condition

System Simulator: 2 cell(cell 1 and cell 2 are active).The initial configurations of the 2 cells in the SS shall follow the values indicated in the column marked "T0" in table 8.4.1.45-1. The table is found in "Test Procedure" clause.

UE: CS-DCCH+DTCH_DCH (State 6-9) or PS-DCCH+DTCH_DCH (State 6-10) in cell 1 as specified in clause 7.4 of TS 34.108, depending on the CN domain supported by the UE.

Test Procedure

Table 8.4.1.45-1 illustrates the downlink power to be applied for the 2 cells at various time instants of the test execution. Column marked "T0" denotes the initial conditions, while column marked "T1" is to be applied subsequently. The exact instants on which these values shall be applied are described in the text in this clause.

Table 8.4.1.45-1

Parameter

Unit

Cell 1

Cell 2

T0

T1

T0

T1

UTRA RFChannel Number

Mid Range Test Frequency

Mid Range Test Frequency

P-CCPCH RSCP

dBm

-65

-65

-70

-60

P-CCPCH TS (3.84 Mcps TDD and 7.68 Mcps TDD)

TS 0

TS 0

The UE is initially in CELL_DCH state of cell 1.

SS transmits MEASUREMENT CONTROL message to request the UE to perform intra-frequency measurement. The key measurement parameters are as follow: measurement type = "intra-frequency measurement", measurement quantity = "PCCPCH RSCP", report criteria = "periodic reporting criteria", reporting interval = "64 seconds". UE shall transmit a MEASUREMENT REPORT message and another after 64 seconds.

SS transmits a new MEASUREMENT CONTROL message to request UE to perform intra-frequency measurement and report Event 1G. All intra-frequency cells are removed, and Cell 2 is included as new intra-frequency cell. SS checks to see that no MEASUREMENT REPORT messages are sent within the next 64 seconds (which is due to periodic reporting).

SS reconfigures the downlink transmission power settings according to values in column "T1" in table 8.4.1.45-1. The UE shall transmit a MEASUREMENT REPORT message when it detects that the PCCPCH RSCP of cell 2 and indicating Cell 2 as a best cell. SS calls for generic procedure C.3 to check that UE is in CELL_DCH state.

Expected Sequence

Step

Direction

Message

Comment

UE

SS

0

The UE is in CELL_DCH of cell 1.

1

MEASUREMENT CONTROL

Intra-frequency measurement is configured.

2

MEASUREMENT REPORT

The message should be repeated after 64 seconds

3

MEASUREMENT REPORT

4

MEASUREMENT CONTROL

Event 1G is configured

5

SS wait for 64seconds to verify that no MEASUREMENT REPORTmessage is received

6

SS re-adjusts the downlink transmission power settings according to columns "T1" in table 8.4.1.45-1.

7

MEASUREMENT REPORT

UE report that Event 1G is triggered and cell 2 is the best cell

8



CALL C.3

If the test result of C.3 indicates that UE is in CELL_DCH state, the test passes, otherwise it fails.

Specific Message Content

MEASUREMENT CONTROL (Step 1) (1.28 Mcps TDD)

Information Element

Value/remark

Measurement identity

16

Measurement command

Setup

– CHOICE measurement type

Intra-frequency measurement

– Intra Frequency Cell Info List

– CHOICE Intra-frequency cell removal

Remove no intra-frequency cells

– New intra-frequency info list

– Intra-frequency cell id

1

– Cell info

– Cell individual offset

0 dB

– Reference time difference to cell

Not Present

– Read SFN Indicator

FALSE

– CHOICE mode

TDD

– Primary CCPCH Info

– CHOICE TDD option

1.28 Mcps TDD

– Cell parameters ID

Set to same cell parameters ID as used for cell 1

– Cell for measurement

Not Present

– Intra-frequency measurement quantity

– Filter coefficient

0

– Measurement quantity

P-CCPCH RSCP

– Intra-frequency reporting quantity

– Reporting quantities for active set cells

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– PCCPCH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting quantities for monitored set cells

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– PCCPCH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting quantities for detected cells

Not Present

– Reporting cell status

– CHOICE reported cell

Report cells within active and/or monitored set on used frequency or within active and/or monitored set on non-used frequency

– Maximum number of reported cells

3

– Measurement validity

Not Present

– CHOICE report criteria

Periodical reporting criteria

– Amount of reporting

Infinity

– Reporting interval

64 sec

Measurement reporting mode

– Transfer Mode

Acknowledged mode

– Periodical or event trigger

Periodical reporting

Additional measurement list

Not Present

DPCH compressed mode status

Not Present

MEASUREMENT CONTROL (Step 1) (3.84 Mcps TDD)

Information Element

Value/remark

Measurement identity

16

Measurement command

Setup

– CHOICE measurement type

Intra-frequency measurement

– Intra Frequency Cell Info List

– CHOICE Intra-frequency cell removal

Remove no intra-frequency cells

– New intra-frequency info list

– Intra-frequency cell id

1

– Cell info

– Cell individual offset

0 dB

– Reference time difference to cell

Not Present

– Read SFN Indicator

FALSE

– CHOICE mode

TDD

– Primary CCPCH Info

– CHOICE TDD option

3.84 Mcps TDD

– CHOICE SyncCase

Sync Case 1

– Timeslot

0

– Cell parameters ID

Set to same cell parameters ID as used for cell 1

– Cell for measurement

Not Present

– Intra-frequency measurement quantity

– Filter coefficient

0

– Measurement quantity

P-CCPCH RSCP

– Intra-frequency reporting quantity

– Reporting quantities for active set cells

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– PCCPCH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting quantities for monitored set cells

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– PCCPCH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting quantities for detected cells

Not Present

– Reporting cell status

Not Present

– Measurement validity

Not Present

– CHOICE report criteria

Periodical reporting criteria

– Amount of reporting

Infinity

– Reporting interval

64 sec

Measurement reporting mode

– Transfer Mode

Acknowledged mode

– Periodical or event trigger

Periodical reporting

Additional measurement list

Not Present

DPCH compressed mode status

Not Present

MEASUREMENT CONTROL (Step 1) (7.68 Mcps TDD)

Information Element

Value/remark

Measurement identity

16

Measurement command

Setup

– CHOICE measurement type

Intra-frequency measurement

– Intra Frequency Cell Info List

– CHOICE Intra-frequency cell removal

Remove no intra-frequency cells

– New intra-frequency info list

– Intra-frequency cell id

1

– Cell info

– Cell individual offset

0 dB

– Reference time difference to cell

Not Present

– Read SFN Indicator

FALSE

– CHOICE mode

TDD

– Primary CCPCH Info

– CHOICE TDD option

7.68 Mcps TDD

– CHOICE SyncCase

Sync Case 1

– Timeslot

0

– Cell parameters ID

Set to same cell parameters ID as used for cell 1

– Cell for measurement

Not Present

– Intra-frequency measurement quantity

– Filter coefficient

0

– Measurement quantity

P-CCPCH RSCP

– Intra-frequency reporting quantity

– Reporting quantities for active set cells

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– PCCPCH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting quantities for monitored set cells

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– PCCPCH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting quantities for detected cells

Not Present

– Reporting cell status

Not Present

– Measurement validity

Not Present

– CHOICE report criteria

Periodical reporting criteria

– Amount of reporting

Infinity

– Reporting interval

64 sec

Measurement reporting mode

– Transfer Mode

Acknowledged mode

– Periodical or event trigger

Periodical reporting

Additional measurement list

Not Present

DPCH compressed mode status

Not Present

MEASUREMENT REPORT (Step 2 and 3) (TDD)

Information Element

Value/remark

Measurement identity

Check to see if set to 16

Measured Results

– CHOICE measurement

Check to see if set to “Intra-frequency measured results list”

– Cell measured results

– Cell Identity

Check to see if is absent

– Cell synchronisation information

Check to see if is absent

– cell parameters ID

Check to see if it is the same for cell 1

– PCCPCH RSCP

Check to see if is present and value is reasonable

– Pathloss

Check to see if is absent

Measured results on RACH

Check to see if is absent

Additional measured results

Check to see if is absent

Event results

Check to see if is absent

MEASUREMENT CONTROL (Step 4) (TDD)

Information Element

Value/remark

Measurement identity

16

Measurement command

Setup

– CHOICE measurement type

Intra-frequency measurement

– Intra Frequency Cell Info List

– CHOICE Intra-frequency cell removal

Remove all intra-frequency cells

– New intra-frequency info list

– Intra-frequency cell id

1

– Cell info

– Cell individual offset

0 dB

– Reference time difference to cell

Not Present

– Read SFN Indicator

FALSE

– CHOICE mode

TDD

– Primary CCPCH Info

Set to same cell parameters ID as used for cell 1

– Intra-frequency cell id

2

– Cell info

– Cell individual offset

0 dB

– Reference time difference to cell

Not Present

– Read SFN Indicator

FALSE

– CHOICE mode

TDD

– Primary CCPCH Info

Set to same cell parameters ID as used for cell 2

– Cell for measurement

Not Present

– Intra-frequency measurement quantity

– Filter coefficient

0

– Measurement quantity

P-CCPCH RSCP

– Intra-frequency reporting quantity

– Reporting quantities for active set cells

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– PCCPCH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting quantities for monitored set cells

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– PCCPCH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting quantities for detected cells

Not Present

– Reporting cell status

Not Present

– Measurement validity

Not Present

– CHOICE report criteria

Intra-frequency measurement reporting criteria

– Parameters required for each events

– Intra-frequency event identity

1g

– Triggering condition 1

Not Present

– Triggering condition 2

Not Present

– Reporting range Constant

Not Present

– Cells forbidden to affect reporting range

Not Present

– W

Not Present

– Hysteresis

2 (1 dB)

– Reporting deactivation threshold

Not Present

– Replacement activation threshold

Not Present

– Time to trigger

0 ms

– Amount of reporting

Infinity

– Reporting interval

Not Present

– Reporting cell status

Not Present

– CHOICE reported cell

Report cells within active and/or monitored set on used frequency or within active and/or monitored set on non-used frequency

– Maximum number of reported cells

2

Measurement reporting mode

– Transfer Mode

Acknowledged mode

– Periodical or event trigger

Event trigger

Additional measurement list

Not Present

DPCH compressed mode status

Not Present

MEASUREMENT REPORT (Step 7) (TDD)

Information Element

Value/remark

Measurement identity

Check to see if set to 16

Measured Results

– CHOICE measurement

Check to see if set to “Intra-frequency measured results list”

– Cell measured results

– Cell Identity

Check to see if is absent

– Cell synchronisation information

Check to see if is absent

– cell parameters ID

Check to see if it is the same for cell 1

– PCCPCH RSCP

Check to see if is present and value is reasonable

– Pathloss

Check to see if is absent

– Cell Identity

Check to see if is absent

– Cell synchronisation information

Check to see if is absent

– cell parameters ID

Check to see if it is the same for cell 2

– PCCPCH RSCP

Check to see if is present and value is reasonable

– Pathloss

Check to see if is absent

Measured results on RACH

Check to see if is absent

Additional measured results

Check to see if is absent

Event results

Check to see if is absent

– CHOICE event result

Check to see if set to “Intra-frequency measurement event results”

– Intra-frequency event identity

Check to see if set to “1g”

– Cell measurement event results

– CHOICE mode

Check to see if set to “TDD”

– Cell parameters Id

Check to see if it is the same for cell 2

8.4.1.45.5 Test Requirement

After step 1, the UE shall transmit MEASUREMENT REPORT message periodically with the interval of 64 seconds.

After step 4, the UE shall not transmit any MEASUREMENT REPORT message.

After step 6, the UE shall transmit MEASUREMENT REPORT message, containing measured results for P-CCPCH RSCP. The ‘Event results’ IE contains event identity 1G.

8.4.1.46 Void

8.4.1.47 Measurement Control and Report: Event triggered periodic measurement for event 1B (FDD)

8.4.1.47.1 Definition

8.4.1.47.2 Conformance requirement

When an intra-frequency measurement configuring event 1b is set up, the UE shall:

1> create a variable TRIGGERED_1B_EVENT related to that measurement, which shall initially be empty;

1> delete this variable when the measurement is released.

When event 1B is configures in the UE, the UE shall:

1> if "Measurement quantity" is "pathloss" and Equation 1 below is fulfilled for one or more primary CPICHs, or if "Measurement quantity" is "CPICH Ec/N0" or "CPICH RSCP", and Equation 2 below is fulfilled for one or more primary CPICHs, for each of these primary CPICHs:

2> if all required reporting quantities are available for that cell, and if the equations have been fulfilled for a time period indicated by "Time to trigger", and if that primary CPICH is part of cells allowed to trigger the event according to "Triggering condition 1", and if that primary CPICH is not included in the "cells triggered" in the variable TRIGGERED_1B_EVENT:

3> include that primary CPICH in the "cells recently triggered" in the variable TRIGGERED_1B_EVENT.

1> if any primary CPICHs are stored in the "cells recently triggered" in the variable TRIGGERED_1B_EVENT:

2> if "Periodic reporting info-1b" is present, and "Reporting interval" for this event is not equal to 0:

3> if the IE "Periodical reporting running" in the variable TRIGGERED_1B_EVENT is set to FALSE:

4> start a timer with the value of "Reporting interval" for this event and set the IE "Periodical reporting running" in the variable TRIGGERED_1B_EVENT to TRUE;

3> set "sent reports" for the primary CPICHs in "cells recently triggered" in the variable TRIGGERED_1B_EVENT to 1.

2> send a measurement report with IEs set as below:

3> set in "intra-frequency measurement event results": "Intrafrequency event identity" to "1b"; and

3> include in "cell measurement event results" all entries of "cells recently triggered" in the variable TRIGGERED_1B_EVENT in ascending order according to the configured measurement quantity taking into account the cell individual offset for each of those cells;

3> set the IE "measured results" and the IE "additional measured results" according to subclause 8.4.2, not taking into account the cell individual offset for each cell.

2> move all entries from IE "cells recently triggered" to "cells triggered" in the variable TRIGGERED_1B_EVENT.

1> if the timer for the periodical reporting has expired:

2> if any primary CPICH is included in the "cells triggered" in the variable TRIGGERED_1B_EVENT:

  1. if "Periodic reporting info-1b" is present:

4> if "Reporting interval" is not equal to 0, and if "Amount of reporting" is greater than "sent reports" stored for any of these primary CPICHs, in "cells triggered" in the variable TRIGGERED_1B_EVENT:

5> increment the stored counter "sent reports" for all CPICHs in "cell triggered" in variable TRIGGERED_1B_EVENT;

5> start a timer with the value of "Reporting interval-1b" for this event;

5> send a measurement report with IEs set as below:

6> set in "intra-frequency measurement event results": "Intrafrequency event identity" to "1b"; and

6> include in "cell measurement event results" all entries of the variable TRIGGERED_1B_EVENT with value of IE "sent reports" smaller than value of "Amount of reporting" in ascending order according to the configured measurement quantity taking into account the cell individual offset for each of those cells;

6> set the IE "measured results" and the IE "additional measured results" according to subclause 8.4.2, not taking into account the cell individual offset for each cell.

5> if "sent reports" in variable TRIGGERED_1B_EVENT is greater than "Amount of reporting" for all entries:

6> set the IE "Periodical Reporting running" in the variable TRIGGERED_1B_EVENT to FALSE and disable the timer for the periodical reporting.

1> if "Measurement quantity" is "pathloss" and Equation 3 below is fulfilled for a primary CPICH, or if "Measurement quantity" is "CPICH Ec/N0" or "CPICH RSCP", and Equation 4 below is fulfilled for a primary CPICH; or

1> if a primary CPICH is no longer part of the cells allowed to trigger the event according to the "Triggering condition 1":

2> if that primary CPICH is included in the "cells triggered" in the variable TRIGGERED_1B_EVENT:

3> remove the entry of that primary CPICH from "cells triggered" in the variable TRIGGERED_1B_EVENT.

————————————————————————————————————–

When a cell enters the removal range and triggers event 1B, the UE shall transmit a MEASUREMENT REPORT to the UTRAN and typically this may result in the removal of the weakest active cell. If the UTRAN is unable to receive MEASUREMENT REPORT after the maximum retransmission, it is beneficial to receive continuous reports in this case as well.

The UE shall revert to periodical measurement reporting if the UTRAN does not update the active set after the transmission of the measurement report. This is illustrated in Figure 14.1.4.1a. During periodic reporting the UE shall transmit MEASUREMENT REPORT messages to the UTRAN at predefined intervals.

Event-triggered periodic measurement reporting shall be terminated if:

1> there are no longer any monitored cell(s) within the removal range; or

1> the UTRAN has removed cells from the active set so that there are no longer the minimum amount of active cells for event 1B to be triggered; or

1> the UE has sent the maximum number of MEASUREMENT REPORT messages (defined by the "amount of reporting" parameter).

The reporting period is assigned by the UTRAN (with the "Reporting interval" parameter). If the reporting interval is set to zero, event-triggered periodic measurement reporting shall not be applied.

Reference

3GPP TS 25.331 clause 14.1.2.2, clause 14.1.4.1a

8.4.1.47.3 Test Purpose

  1. To confirm that the UE reverts to periodical measurement reporting of event 1B, after event 1B has been initially triggered, when primary CPICH currently measured by the UE leaves the reporting range.
  2. To confirm that the event triggered periodic measurement reporting is terminated after UE no longer finds any monitored cell within the removal range.
  3. To confirm that the event triggered periodic measurement reporting is terminated after UTRAN has removed cells from the active set so that there is no longer the minimum amount of active cells for event 1B to be triggered.
  4. To confirm that the event triggered periodic measurement is no longer triggered if the reporting interval is set to zero.
  5. To confirm that the event-triggered periodic measurement reporting is terminated after UE has sent the maximum number of MEASUREMENT REPORT messages (defined by the "amount of reporting" parameter).

8.4.1.47.4 Method of test

Initial Condition

System Simulator: 2 Cells – Cell 1, Cell 2 are active.

UE: CS-DCCH+DTCH_DCH (State 6-9) or PS-DCCH+DTCH_DCH (State 6-10) in cell 1 as specified in clause 7.4 of TS 34.108, depending on the CN domain supported by the UE.

Test Procedure

Table 8.4.1.47-1

Parameter

Unit

Cell1

Cell2

T0

T1

T0

T1

UTRA RF Channel

Mid Range Test Frequency

Mid Range Test Frequency

CPICH Ec

dBm/3.84MHz

-60

-60

-66

-75

Table 8.4.1.47-1 illustrates the downlink power to be applied for the 2 cells at various time instants of the test execution.

The UE is initially in CELL_DCH state in Cell 1 with the downlink transmission power settings according to values in column “T0” in table 8.4.1.47-1.
SS sends a MEASUREMENT CONTROL message to set up events 1A & 1B. In this message the IE “periodicReportingInfo-1b” is included with “reportingInterval” set to a non-zero value. The IE "reporting range" is set to 9dB. The UE shall send a MEASUREMENT REPORT on the uplink DCCH, which contains the IE "Event results" to report that event 1A has been triggered by Cell 2.
SS executes the ACTIVE SET UPDATE procedure, requesting Cell 2 to be added to the active set. When the UE receives this message, it shall configure layer 1 to begin reception without affecting the current uplink and downlink activities of existing radio links. The UE shall transmit an ACTIVE SET UPDATE COMPLETE message to the SS on the uplink DCCH using AM RLC.

SS reconfigures the downlink transmission power settings according to values in column “T1” in table 8.4.1.47-1. The UE shall transmit a MEASUREMENT REPORT message on the uplink DCCH to report the triggering of event 1B. In this message, the IE "Events results" shall indicate that event 1B has been triggered by Cell 2. SS does not respond to the first report and waits for a few more reports, say half the number of the value as defined by the IE "amount of reporting" in the MEASUREMENT CONTROL message.

SS now reconfigures the downlink transmission power settings according to values in column “T0” in table 8.4.1.47-1 so as to get the power levels of Cell 2 go above event 1B reporting range threshold. UE now stops triggering any more event 1B measurement reports.

SS reconfigures the downlink transmission power settings according to values in column “T1” in table 8.4.1.47-1. UE shall transmit a MEASUREMENT REPORT message on the uplink DCCH to report the triggering of event 1B. In this message, the IE "Events results" shall indicate that event 1B has been triggered by Cell 2. SS waits for a few reports, say half the number of the value as defined by the IE "amount of reporting" in the MEASUREMENT CONTROL message.

SS executes the ACTIVE SET UPDATE procedure, requesting Cell 2 to be removed from the active set. The UE shall respond with ACTIVE SET UPDATE COMPLETE message on the uplink DCCH indicating the successful removal of Cell 2 from the current active set. . The UE should however stop transmitting Measurement Reports for event 1B for Cell 2, as Cell 1 is now the only active cell. SS waits for 10s to make sure that no further measurement reports for event 1B are triggered.

SS sends a MEASUREMENT CONTROL message to modify the configuration of event 1B. The IE “reporting interval” is now set to zero.

SS executes the ACTIVE SET UPDATE procedure, requesting Cell 2 to be added to the active set. When the UE receives this message, the UE shall configure layer 1 to begin reception without affecting the current uplink and downlink activities of existing radio links. The UE shall transmit an ACTIVE SET UPDATE COMPLETE message to the SS on the uplink DCCH using AM RLC.

The UE shall send a MEASUREMENT REPORT on the uplink DCCH, which contains the IE "Event results" to report that intra-frequency event 1B is triggered by Cell 2. SS waits for 10s to make sure that no further Measurement Reports are triggered for event 1B.

SS reconfigures the downlink transmission power settings according to values in column “T0” in table 8.4.1.47-1 and sends a MEASUREMENT CONTROL message to modify the configuration of event 1B. The IE “reportingInterval” is set back to a non-zero value.

SS reconfigures the downlink transmission power settings according to values in column “T1” in table 8.4.1.47-1.
The UE shall transmit a MEASUREMENT REPORT message on the uplink DCCH to report the triggering of event 1B. In this message, the IE "Events results" shall indicate that event 1B is triggered by Cell 2. SS waits to receive the full number of reports as defined by the IE "amount of reporting" in the last received MEASUREMENT CONTROL message. SS waits for 10s to make sure that no further measurement reports are triggered.

SS calls for generic procedure C.3 to check that UE is in CELL_DCH state.

Expected Sequence

Step

Direction

Message

Comment

UE

SS

1

MEASUREMENT CONTROL

UE is initially in CELL_DCH state in Cell 1.

SS set up events 1A & 1B in the UE. The IE “PeriodicReportingInfo-1b” is present with “reportingInterval” set to a non zero value.

2

MEASUREMENT REPORT

Measurement made on Cell 2 shall trigger event 1A.

3

ACTIVE SET UPDATE

SS requests UE to add Cell 2 into the active set.

4

ACTIVE SET UPDATE COMPLETE

5

SS configures the downlink power according to column “T1” of table 8.4.1.47-1.

6

MEASUREMENT REPORT

Measurement made on Cell 2 shall trigger event 1B and should be repeated every 8s.

7

SS waits for half the number of event 1B reports, i.e. half to that mentioned in the IE “amount of reporting”.

8

SS configures the downlink power according to column “T0” of table 8.4.1.47-1.

9

SS waits for 10s to verify that no MEASUREMENT REPORT for Event 1B message is received.

10

SS configures the downlink power according to column “T1” of table 8.4.1.47-1.

11

MEASUREMENT REPORT

Measurement made on Cell 2 shall trigger event 1B & should be repeated every 8s. SS waits for half the number of reports, i.e. half to that mentioned in the IE “amount of reporting”.

12

ACTIVE SET UPDATE

SS requests UE to remove Cell 2 from the active set.

13

ACTIVE SET UPDATE COMPLETE

Only Cell 1 is in the active set now.

14

Void

15

.

SS checks that no measurement report for Event 1B is sent by the UE for 10s.

16

MEASUREMENT CONTROL

Event 1B configuration is modified, “reporting Interval” is now set to ‘no periodical reporting’.

17

ACTIVE SET UPDATE

SS requests UE to add Cell 2 to the active set.

18

ACTIVE SET UPDATE COMPLETE

Cell 1 & Cell 2 are in the active set now.

19

MEASUREMENT REPORT

Triggers just one measurement report indicating event 1B (periodic event triggered measurements terminated)

20

SS checks that no measurement report is sent by the UE for 10s.

21

SS configures the downlink power according to column “T0” of table 8.4.1.47-1.

22

MEASUREMENT CONTROL

Event 1B configuration is modified, “reporting Interval” is now set back to a non-zero value.

23

SS configures the downlink power according to column “T1” of table 8.4.1.47-1.

24

MEASUREMENT REPORT

Measurement made on cell 2 shall trigger event 1B

25

SS waits to receive the full number of reports as defined in the IE "amount of reporting" in Measurement Control

26

SS checks that no measurement report is sent by the UE for 10s.

27



CALL C.3

If the test result of C.3 indicates that UE is in CELL_DCH state, the test passes, otherwise it fails.

Specific Message Contents

All messages indicated below shall use the same content as described in default message content found in [9] TS 34.108 clause 9, with the following exceptions:

MEASUREMENT CONTROL (Step 1)

Information Element

Value/remark

RRC transaction identifier

1

Measurement Identity

1

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Event Trigger

Additional measurements list

Not Present

CHOICE measurement type

Intra-frequency measurement

– Intra-frequency cell info list

– CHOICE intra-frequency cell removal

Remove no intra-frequency

– New intra-frequency info list

– Intra-frequency cell id

2

– Cell info

– Cell individual offset

Not present

Absence of this IE is equivalent to default value 0dB

– Reference time difference to cell

Not Present

– Read SFN Indicator

TRUE

– CHOICE Mode

FDD

– Primary CPICH Info

– Primary Scrambling Code

Set to same code as used for cell 2

– Primary CPICH TX power

Not Present

– TX Diversity Indicator

FALSE

– Cell for measurement

– Intra-frequency cell id

1, 2

– Intra-frequency measurement quantity

– Filter Coefficient

0

– Measurement quantity

CPICH RSCP

– Intra-frequency reporting quantity

– Reporting quantities for active set cells

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CPICH Ec/No reporting indicator

FALSE

– CPICH RSCP reporting indicator

FALSE

– Pathloss reporting indicator

FALSE

– Reporting quantities for monitored set cells

– Cell synchronisation information reporting indicator

TRUE

– Cell identity reporting indicator

FALSE

– CPICH Ec/No reporting indicator

FALSE

– CPICH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting quantities for detected cells

Not present

– Reporting cell status

Not present

– Measurement validity

Not present

– CHOICE report criteria

Intra-frequency measurement reporting criteria

– Parameters required for each events

– Intra-frequency event identity

1a

– Triggering conditions 1

Not Present

– Triggering conditions 2

Monitored set cells

– Reporting range

18 (9.0 dB)

– Cells forbidden to affect reporting range

Not Present

– W

0

– Hysteresis

0 (0 dB)

– Threshold used frequency

Not Present

– Reporting deactivation threshold

3

– Replacement activation threshold

Not Present

– Time to trigger

0 msec

– Amount of reporting

1

– Reporting interval

No periodical reporting

– Reporting cell status

– CHOICE reported cells

Report cells within monitored set on used frequency

– Maximum number of reported cells

2

– Intra-frequency event identity

1b

– Triggering conditions 1

ActiveSetCellsOnly

– Triggering conditions 2

Not Present 

– Reporting range

18 (9.0 dB)

– Cells forbidden to affect reporting range

Not Present

– W

0

– Reporting deactivation threshold

Not Present

– Replacement activation threshold

Not Present

– Hysteresis

0 (0 dB)

– Threshold used frequency

Not Present

– Time to trigger

0 msec

– Reporting cell status

Not Present

– PeriodicReportingInfo-1b

– Amount of reporting

16

– Reporting interval

8000

DPCH compressed mode status info

Not Present

MEASUREMENT REPORT (Step 2)

Information Element

Value/remark

Measurement identity

Check to see if set to 1

Measured Results

– CHOICE measurement

Check to see if set to "Intra-frequency measured results list"

– Intra-frequency measurement results

– Cell measured results

– Cell Identity

Check to see if it is absent

– Cell synchronisation information

Checked that this IE is present and includes IE COUNT-C-SFN frame difference

– Primary CPICH Info

– Primary Scrambling Code

Check to see if it’s the same code for Cell 2

– CPICH Ec/No

Check to see if this IE is absent

– CPICH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

Measured Results on RACH

Check to see if this IE is absent

Additional Measured Results

Check to see if this IE is absent

Event Results

Check to see if set to ‘Intra-frequency measurement event results’

– Intra-frequency event identity

Check to see if set to ‘1a’

– Cell measurement event results

– CHOICE Mode

Check to see if set to ‘FDD’

– Primary CPICH info

– Primary Scrambling Code

Check to see if set to the same code for Cell 2

ACTIVE SET UPDATE (Step 3 & 17)

Information Element

Value/remark

RRC transaction identifier

0

Radio link addition information

– Primary CPICH Info

– Primary Scrambling Code

Set to same code as assigned for Cell 2

– Downlink DPCH info for each RL

– CHOICE mode

FDD

– Primary CPICH usage for channel estimation

P-CPICH can be used

– DPCH frame offset

Calculated value from Cell synchronisation information

– Secondary CPICH info

Not Present

– DL channelisation code

This IE is repeated for all existing downlink DPCHs allocated to the UE

– Secondary scrambling code

1

– Spreading factor

Refer to TS 34.108 clause 6.10.2.4 "Typical radio parameter sets"

– Code Number

For each DPCH, assign the same code number in the current code given in Cell 1.

– Scrambling code change

Not Present

– TPC Combination Index

0

– SSDT Cell Identity

Not Present

– Close loop timing adjustment mode

Not Present

– TFCI Combining Indicator

FALSE

– SCCPCH information for FACH

Not Present

Radio link removal information

Not Present

ACTIVE SET UPDATE COMPLETE (Steps 4, 13 & 18)

Information Element

Value/remark

RRC transaction identifier

Check to see if it is set to 0

MEASUREMENT REPORT (Steps 6, 7, 11, 19, 24 & 25)

Information Element

Value/remark

Measurement identity

Check to see if set to 1

Measured Results

Check to see if this IE is absent

Measured Results on RACH

Check to see if this IE is absent

Additional Measured Results

Check to see if this IE is absent

Event Results

Check to see if set to ‘Intra-frequency measurement event results’

– Intra-frequency event identity

Check to see if set to ‘1b’

– Cell measurement event results

– CHOICE Mode

Check to see if set to ‘FDD’

– Primary CPICH info

– Primary Scrambling Code

Check to see if set to the same code for Cell 2

ACTIVE SET UPDATE (Step 12)

Information Element

Value/remark

RRC transaction identifier

0

Radio link removal information

– Primary CPICH Info

– Primary Scrambling Code

Set to same code as assigned for Cell 2

MEASUREMENT CONTROL (Step 16)

Information Element

Value/remark

RRC transaction identifier

1

Measurement Identity

1

Measurement Command

Modify

Measurement Reporting Mode

Not Present

Additional measurements list

Not Present

CHOICE measurement type

Intra-frequency measurement

– Intra-frequency cell info list

Not Present

– Intra-frequency measurement quantity

Not Present

– Intra-frequency reporting quantity

Not Present

– Measurement validity

Not present

– CHOICE report criteria

Intra-frequency measurement reporting criteria

– Parameters required for each events

– Intra-frequency event identity

1b

– Triggering conditions 1

ActiveSetCellsOnly

– Triggering conditions 2

Not Present

– Reporting range

18 (9.0 dB)

– Cells forbidden to affect reporting range

Not Present

– W

0

– Reporting deactivation threshold

Not Present

– Replacement activation threshold

Not Present

– Hysteresis

0 (0 dB)

– Threshold used frequency

Not Present

– Time to trigger

100 msec

– Reporting cell status

Not present

– PeriodicReportingInfo-1b

– Amount of reporting

16

– Reporting interval

No periodical reporting

DPCH compressed mode status info

Not Present

MEASUREMENT CONTROL (Step 22)

Information Element

Value/remark

RRC transaction identifier

1

Measurement Identity

1

Measurement Command

Modify

Measurement Reporting Mode

Not Present

Additional measurements list

Not Present

CHOICE measurement type

Intra-frequency measurement

– Intra-frequency event identity

1b

– Triggering conditions 1

ActiveSetCellsOnly

– Triggering conditions 2

Not Present

– Reporting range

18 (9.0 dB)

– Cells forbidden to affect reporting range

Not Present

– W

0

– Reporting deactivation threshold

Not Present

– Replacement activation threshold

Not Present

– Hysteresis

(0 dB)

– Threshold used frequency

Not Present

– Time to trigger

0 msec

– Reporting cell status

Not present

– PeriodicReportingInfo-1b

– Amount of reporting

16

– Reporting interval

8000

DPCH compressed mode status info

Not Present

8.4.1.47.5 Test requirement

After step 1, the UE shall send a MEASUREMENT REPORT message on the uplink DCCH. The message shall contain the IE "Event results" to report that Cell 2 has triggered intra-frequency event 1A.

After step 3, the UE shall send an ACTIVE SET UPDATE COMPLETE message on the uplink DCCH indicating the successful addition of Cell 2 to the active set.

After step 5, the UE shall transmit a number of MEASUREMENT REPORTS on the uplink DCCH. The message shall contain IE "Event results" to report that Cell 2 has triggered intra-frequency event 1B.

After step 10, the UE shall start to transmit a number of MEASUREMENT REPORTS on the uplink DCCH. The message shall contain IE "Event results" to report that Cell 2 has triggered intra-frequency event 1B.

After step 12, the UE shall send an ACTIVE SET UPDATE COMPLETE message on the uplink DCCH indicating the successful removal of Cell 2 from the active set.

After step 17, UE shall send an ACTIVE SET UPDATE COMPLETE message on the uplink DCCH indicating the successful addition of Cell 2 to the active set.

After step 18, the UE shall transmit just one MEASUREMENT REPORT message on the uplink DCCH indicating that the periodic event-triggered reporting is now terminated for event 1B. The message shall contain IE "Event results" to report that Cell 2 has triggered intra-frequency event 1B.

After step 23, the UE shall start to transmit a series of MEASUREMENT REPORTs equal to the number as mentioned in the IE ‘ amount of reports’, on the uplink DCCH with the IE "Event results” indicating that Cell 2 has triggered intra-frequency event 1B.

SS waits to see that no further Measurement reports are received in addition to what is mentioned in the IE ’amount of reporting’.

8.4.1.48 Measurement Control and Report: Combined Inter-frequency measurement for event 2b and Inter-RAT measurement, event 3a (FDD)

8.4.1.48.1 Definition

8.4.1.48.2 Conformance requirement

When event 2b is configured in the UE within a measurement, the UE shall:

1> if equations 1 and 2 below have been fulfilled for a time period indicated by "Time to Trigger" from the same instant, respectively for one or several non-used frequencies included for that event and for the used frequency:

2> if any of those non-used frequency is not stored in the variable TRIGGERED_2B_EVENT:

3> store the non-used frequencies that triggered the event and that were not previously stored in the variable TRIGGERED_2B_EVENT into that variable;

3> send a measurement report with IEs set as below:

4> set in "inter-frequency measurement event results":

5> "inter-frequency event identity" to "2b"; and

5> for each non-used frequency that triggered the event, beginning with the best frequency:

6> "Frequency info" to that non-used frequency; and

6> "Non frequency related measurement event results" to the "Primary CPICH info" of the best primary CPICH for FDD cells or "Primary CCPCH info" to the "Cell parameters ID" of the best primary CCPCH for TDD cells on that non-used frequency, not taking into account the cell individual offset;

4> set the IE "measured results" and the IE "additional measured results" according to TS 25.331 subclause 8.4.2, not taking into account the cell individual offset;

1> if equation 3 below is fulfilled for a non-used frequency stored in the variable TRIGGERED_2B_EVENT:

2> remove that non-used frequency from the variable TRIGGERED_2B_EVENT.

1> if equation 4 below is fulfilled for the used frequency:

2> clear the variable TRIGGERED_2B_EVENT.

Triggering conditions:

Equation 1:

The variables in the formula are defined as follows:

QNon used is the quality estimate of a non-used frequency that becomes better than an absolute threshold.

TNon used 2b is the absolute threshold that applies for this non-used frequency in that measurement.

H2b is the hysteresis parameter for the event 2b.

Equation 2:

The variables in the formula are defined as follows:

QUsed is the quality estimate of the used frequency.

TUsed 2b is the absolute threshold that applies for the used frequency in that measurement.

H2b is the hysteresis parameter for the event 2b.

Leaving triggered state condition:

Equation 3:

The variables in the formula are defined as follows:

QNon used is the quality estimate of a non-used frequency that is stored in the variable TRIGGERED_2B_EVENT.

TNon used 2b is the absolute threshold that applies for this non-used frequency in that measurement.

H2b is the hysteresis parameter for the event 2b.

Equation 4:

The variables in the formula are defined as follows:

QUsed is the quality estimate of the used frequency.

TUsed 2b is the absolute threshold that applies for the used frequency in that measurement.

H2b is the hysteresis parameter for the event 2b.

…..

When an inter-RAT measurement configuring event 3a is set up, the UE shall:

1> create a variable TRIGGERED_3A_EVENT related to that measurement, which shall initially be empty;

1> delete this variable when the measurement is released.

When event 3a is configured in the UE within a measurement, the UE shall:

1> if the other RAT is GSM, and if IE "BSIC verification required" is set to "required":

2> if equations 1 and 2 below have both been fulfilled for a time period indicated by "Time to trigger" from the same instant, respectively for the used UTRAN frequency and for one or several GSM cells that match any of the BCCH ARFCN and BSIC combinations considered in that inter-RAT measurement:

3> if the Inter-RAT cell id of any of those GSM cells is not stored in the variable TRIGGERED_3A_EVENT:

4> store the Inter-RAT cell ids of the GSM cells that triggered the event and that were not previously stored in the variable TRIGGERED_3A_EVENT into that variable.

4> send a measurement report with IEs set as below:

5> in "inter-RAT measurement event result": "inter-RAT event identity" to "3a", "CHOICE BSIC" to "verified BSIC" and "Inter-RAT cell id" to the GSM cells that triggered the event (best one first), taking into account the cell individual offset of the GSM cells;

5> "measured results" and possible "additional measured results" according to subclause 8.6.7.5 and 8.4.2, respectively, not taking into account the cell individual offset.

2> if equation 4 is fulfilled for a GSM cell whose inter-RAT cell id is stored in the variable TRIGGERED_3A_EVENT:

3> remove the inter-RAT cell id of that GSM cell from the variable TRIGGERED_3A_EVENT.

2> if equation 3 is fulfilled for the used frequency in UTRAN:

3> clear the variable TRIGGERED_3A_EVENT.

1> if the other RAT is GSM, and if IE "BSIC verification required" is set to "not required":

2> if equations 1 and 2 below have been fulfilled for a time period indicated by "Time to trigger" from the same instant, respectively for the used UTRAN frequency and for one or several BCCH ARFCNs considered in that inter-RAT measurement:

3> if any of those BCCH ARFCNs is not stored into the variable TRIGGERED_3A_EVENT:

4> store the BCCH ARFCNs that triggered the event and that were not previously stored in the variable TRIGGERED_3A_EVENT into that variable;

4> send a measurement report with IEs set as below:

5> in "inter-RAT measurement event result": "inter-RAT event identity" to "3a", "CHOICE BSIC" to "non verified BSIC" and "BCCH ARFCN" to BCCH ARFCNs that triggered the event (best one first), taking into account the cell individual offset of the GSM cells;

5> "measured results" and possible "additional measured results" according to subclause 8.6.7.5 and 8.4.2, respectively, not taking into account the cell individual offset.

2> if equation 4 is fulfilled for a BCCH ARFCN that is stored in the variable TRIGGERED_3A_EVENT:

3> remove that BCCH ARFCN from the variable TRIGGERED_3A_EVENT.

2> if equation 3 is fulfilled for the used frequency in UTRAN:

3> clear the variable TRIGGERED_3A_EVENT.

Triggering conditions:

Equation 1:

The variables in the formula are defined as follows:

QUsed is the quality estimate of the used UTRAN frequency.

TUsed is the absolute threshold that applies for the used frequency in that measurement.

H3a is the hysteresis parameter for event 3a.

Equation 2:

The variables in the formula are defined as follows:

MOther RAT is the measurement quantity for the cell of the other system.

CIOOther RAT is the cell individual offset for the cell of the other system.

TOther RAT is the absolute threshold that applies for the other system in that measurement.

H3a is the hysteresis parameter for event 3a.

Leaving triggered state conditions:

Equation 3:

The variables in the formula are defined as follows:

QUsed is the quality estimate of the used UTRAN frequency.

TUsed is the absolute threshold that applies for the used frequency in that measurement.

H3a is the hysteresis parameter for event 3a.

Equation 4:

The variables in the formula are defined as follows:

MOther RAT is the measurement quantity for the cell of the other system. MOther RAT is expressed in dBm.

CIOOther RAT is the cell individual offset for the cell of the other system.

TOther RAT is the absolute threshold that applies for the other system in that measurement.

H3a is the hysteresis parameter for event 3a.

H3c is the hysteresis parameter for event 3c.

Reference

3GPP TS 25.331 clauses 14.2.1.2, 14.3.1.1.

8.4.1.48.3 Test Purpose

1. To confirm that the UE sends MEASUREMENT REPORT message when event 2b and 3a are configured and estimated quality of the currently used frequency is below the value of the IE "Threshold used frequency" and the estimated quality of a non-used frequency is above the value of the IE "Threshold non-used frequency". This MEASUREMENT REPORT message shall contain at least the best primary CPICH info of the non-used frequency that triggered the event.

2. To confirm that the UE sends MEASUREMENT REPORT message when event 2b and 3a are configured and estimated quality of the currently used UTRAN frequency is below the value of the IE "Threshold own system" and the estimated quality of the other system is above the value of the IE "Threshold other system". This MEASUREMENT REPORT message shall contain the inter-RAT cell id of the GSM cell that triggered the event.

8.4.1.48.4 Method of test

Initial Condition

System Simulator: 2 UTRAN FDD cells and 1 GSM cell. The initial configurations of the 3 cells in the SS shall follow the values indicated in the column marked "T0" in table 8.4.1.48-1. The table is found in "Test Procedure" clause.

The UTRAN FDD cell 4 shall use UARFCN according to the band under test except in the case of where FDD band II is tested and GSM1900 is used for the Inter-RAT cell, then “Low Range” test frequency for Cell 4 in band II is used instead, to avoid the test channels overlapping.

UE: CS-DCCH+DTCH_DCH (State 6-9) or PS-DCCH+DTCH_DCH (State 6-10) in cell 1 as specified in clause 7.4 of TS 34.108, depending on the CN domain supported by the UE.

Related ICS/IXIT statements

– Compressed mode required yes/no

Test Procedure

Table 8.4.1.48-1 and 8.4.1.48-2 illustrates the downlink power to be applied for the 3 cells at various time instants of the test execution. Column marked "T0" denotes the initial conditions, while columns marked "T1" and "T2" are to be applied subsequently. The exact instants on which these values shall be applied are described in the text in this clause.

Table 8.4.1.48-1

Parameter

Unit

Cell 1

Cell 4

T0

T1

T2

T0

T1

T2

UTRA RF Channel Number

Mid Range Test Frequency

High Range Test Frequency

CPICH Ec (FDD)

dBm/3.84 Mhz

-60

-80

-80

-80

-60

-80

Qrxlevmin

dBm

-115 (Note)

Note Qrxlevmin is set to minimum value (-115) to avoid that cell trigger “out of service” condition.

Table 8.4.1.48-2

Parameter

Unit

Cell 9

(GSM)

T0

T1

T2

Test Channel

GSM Ch.1

BCCH ARFCN

Value according to the GSM band under test (see 3GPP 34.123-1 table 6.5 for details on the ARFCN)

CELL identity

0

BSIC

BSIC 1

RF Signal Level

DBm

-90

-90

-70

The UE is initially in CELL_DCH on Cell1. UTRA cell 1 is the only cell in the active set of the UE. If the UE requires compressed mode (refer ICS/IXIT), the SS sends a PHYSICAL CHANNEL RECONFIGURATION message to the UE to configure the compressed mode pattern sequence parameters to the UE. Four compressed mode patterns: one for inter-frequency handover and three for inter-RAT handover (RSSI, BSIC decoding and BSIC reconfirmation) are configured, according to the message specified below. When the PHYSICAL CHANNEL RECONFIGURATION COMPLETE is received from the UE, the SS sends two MEASUREMENT CONTROL messages to the UE, to set up inter-frequency and inter-RAT measurements respectively. Event 2b and 3a is set up in these message, and if the UE requires compressed mode (refer ICS/IXIT), compressed mode is activated.

The SS then configures the UTRA cells Cell1 and Cell4 and the GSM cell Cell9 according to the values in columns "T1" in table 8.4.1.48-1 and table 8.4.1.48-2. As the estimate for the used frequency is below the threshold configured by the IE " Threshold used frequency " (-70dBm) and the estimate for the non-used frequency is above the threshold configured by the IE "Threshold non-used frequency" (-70dBm) then event 2b is triggered by the UE. The SS waits for the MEASUREMENT REPORT message from the UE reporting event 2b.

The SS then configures the UTRA cells Cell1 and Cell4 and the GSM cell Cell9 according to the values in columns "T2" in table 8.4.1.48-1 and table 8.4.1.48-2. As the estimated quality of the currently used UTRAN frequency is below the value of the IE "Threshold own system" (-70dBm) and the estimated quality of the other system is above the value of the IE "Threshold other system" (-80 dBm) then event 3a is triggered by the UE. The SS waits for a MEASUREMENT REPORT message from the UE reporting event 3a.

The SS calls for generic procedure C.3 to check that UE is in CELL_DCH state.

Expected Sequence

Step

Direction

Message

Comment

UE

SS

1

ß

The UE is brought to the CELL_DCH state in cell 1.

If Compressed Mode not required (refer ICS/IXIT) go to step 4

2

ß

PHYSICAL CHANNEL RECONFIGURATION

SS instructs UE to configure compressed mode patterns for inter-frequency and inter-RAT.

3

à

PHYSICAL CHANNEL RECONFIGURATION COMPLETE

4

ß

MEASUREMENT CONTROL

SS sets measurement parameters for event 2b .

5

ß

MEASUREMENT CONTROL

If UE require compressed mode (refer ICS/IXIT) then SS activates compressed mode operation for Inter-RAT and Inter-frequency.

SS commands the UE to perform Inter-RAT measurements and Inter-frequency to report event 3a and event 2b.

6

 

 

SS re-adjusts the downlink transmission power settings according to columns "T1" in table 8.4.1.48-1 and table 8.4.1.48-2.

7

à

MEASUREMENT REPORT

Measurement report indicating event 2b. This message should come at least 640 ms later after changing power setting of Cell 4. Layer 3 Filtering causes an additional delay.

8

 

 

SS re-adjusts the downlink transmission power settings according to columns "T2" in table 8.4.1.48-1 and table 8.4.1.48-2.

9

à

MEASUREMENT REPORT

Measurement report indicating event 3a. This message should come at least 640 ms later after changing power setting of Cell 9.

10

ßà

CALL C.3

If the test result of C.3 indicates that UE is in CELL_DCH state, the test passes, otherwise it fails.

Specific Message Contents

All messages indicated below shall use the same content as described in default message content, with the following exceptions:

PHYSICAL CHANNEL RECONFIGURATION (Step 2)

Use the same message sub-type found in clause 9 of TS 34.108, which is entitled "(Packet to CELL_DCH from CELL_DCH in PS)", with Scrambling code change set to Default1 and with the following exceptions in the IE(s) concerned:

Four compressed mode patterns: one for inter-frequency handover and three for inter-RAT handover (RSSI, BSIC decoding and BSIC reconfirmation) are configured, based on the compressed mode pattern in clause 6.8.2.2 of 34.108

Information Element

Value/remark

Version

Downlink information common for all radio links

 

– DPCH compressed mode info

 

– TGPSI

1

– TGPS status flag

Deactivate

– TGCFN

Not Present

– Transmission gap pattern sequence configuration parameters

 

– TGMP

FDD Measurement

– TGPRC

Infinity

– TGSN

8

– TGL1

14

– TGL2

Not Present

– TGD

undefined

– TGPL1

12

– TGPL2

Not Present

R99 and Rel-4 only

– RPP

Mode 0

– ITP

Mode 0

– CHOICE UL/DL mode

UL and DL or DL only or UL only depending on UE capability

– Downlink compressed mode method

SF/2

– Uplink compressed mode method

SF/2 or Not present depending on UE capability

– Downlink frame type

A

– DeltaSIR1

20 (2.0)

– DeltaSIRAfter1

10 (1.0)

– DeltaSIR2

Not present

– DeltaSIRAfter2

Not present

– N identify abort

Not present

– T Reconfirm abort

Not present

– TGPSI

2

– TGPS Status Flag

Deactivate

– TGCFN

Not present

– Transmission gap pattern sequence configuration parameters

 

– TGMP

GSM Carrier RSSI Measurement

– TGPRC

Infinity

– TGSN

8

– TGL1

14

– TGL2

Not present

– TGD

60

– TGPL1

24

– TGPL2

Not present

R99 and Rel-4

– RPP

Mode 0

– ITP

Mode 0

CHOICE UL/DL Mode

UL&DL or UL-only or DL-only (depends on UE’s Measurement capability)

– Downlink compressed mode method

SF/2

– Uplink compressed mode method

SF/2 or Not present depending on UE capability

– Downlink frame type

A

– DeltaSIR1

10 (1.0)

– DeltaSIRAfter1

5 (0.5)

– DeltaSIR2

Not Present

– DeltaSIR2After2

Not Present

– N identify abort

Not Present

– T Reconfirm abort

Not Present

– TGPSI

3

– TGPS Status Flag

Deactivate

– TGCFN

Not present

– Transmission gap pattern sequence configuration parameters

 

– TGMP

GSM BSIC identification

– TGPRC

Infinity

– TGSN

8

– TGL1

14

– TGL2

Not present

– TGD

45

– TGPL1

24

– TGPL2

Not present

R99 and Rel-4

– RPP

Mode 0

– ITP

Mode 0

CHOICE UL/DL Mode

UL&DL or UL-only or DL-only (depends on UE’s Measurement capability)

– Downlink compressed mode method

SF/2

– Uplink compressed mode method

SF/2 or Not present depending on UE capability

– Downlink frame type

A

– DeltaSIR1

10 (1.0)

– DeltaSIRAfter1

5 (0.5)

– DeltaSIR2

Not Present

– DeltaSIR2After2

Not Present

– N identify abort

66

– T Reconfirm abort

Not Present

– TGPSI

4

– TGPS Status Flag

Deactivate

– TGCFN

Not present

– Transmission gap pattern sequence configuration parameters

 

– TGMP

GSM BSIC re-confirmation

– TGPRC

Infinity

– TGSN

8

– TGL1

14

– TGL2

Not present

– TGD

undefined

– TGPL1

24

– TGPL2

Not present

R99 and Rel-4

– RPP

Mode 0

– ITP

Mode 0

CHOICE UL/DL Mode

UL&DL or UL-only or DL-only (depends on UE’s Measurement capability)

– Downlink compressed mode method

SF/2

– Uplink compressed mode method

SF/2 or Not present depending on UE capability

– Downlink frame type

A

– DeltaSIR1

10 (1.0)

– DeltaSIRAfter1

5 (0.5)

– DeltaSIR2

Not Present

– DeltaSIR2After2

Not Present

– N identify abort

Not Present

– T Reconfirm abort

10 (5 s)

Downlink information per radio link list

– Choice mode

FDD

– Primary CPICH info

– Primary scrambling code

Ref. to the Default setting in clause 6.1 (FDD)

– PDSCH with SHO DCH info

Not Present

R99 and Rel-4 only

– PDSCH code mapping

Not Present

R99 and Rel-4 only

– Serving HS-DSCH radio link indicator

FALSE

Rel-5

– Serving E-DCH radio link indicator

FALSE

Rel-6

– Downlink DPCH info for each RL

– CHOICE mode

FDD

– Primary CPICH usage for channel estimation

Primary CPICH may be used

– DPCH frame offset

Set to value : Default DPCH Offset Value (as currently stored in SS) mod 38 400

– Secondary CPICH info

Not Present

– DL channelisation code

– Secondary scrambling code

5

– Spreading factor

Reference to clause 6.10 Parameter Set

– Code number

0

– Scrambling code change

Set to value Default1: No code change (if the UE has a compressed mode pattern sequence configured in variable TGPS_IDENTITY or included in the message including IE "Downlink DPCH info for each RL", which is using compressed mode method "SF/2")

– TPC combination index

0

– SSDT Cell Identity

Not Present

R99 and Rel-4 only

– Closed loop timing adjustment mode

Not Present

– E-AGCH Info

Not Present

Rel-6

– E-HICH Information

Not Present

Rel-6

– E-RGCH Information

Not Present

Rel-6

– SCCPCH information for FACH

Not Present

R99 and Rel-4 only

MEASUREMENT CONTROL (Step 4)

Information Element

Value/remark

Measurement identity

2

Measurement command

Setup

Measurement reporting mode

 

– Measurement reporting transfer mode

Acknowledged mode RLC

– Periodic reporting / Event trigger reporting mode

Event trigger

Additional measurement list

Not present

CHOICE measurement type

Inter-frequency measurement

– Inter-frequency cell info list

 

– Inter-frequency cell removal

Not present

– New inter-frequency info list

 

– Inter-frequency cell id

Id of Cell 4

– Frequency Information

Frequency of Cell 4

– Cell info

 

– Cell individual offset

Default value

– Reference time difference to cell

Not present

– CHOICE mode

FDD

– Read SFN Indicator

FALSE

– Primary CPICH Info

 

– Primary scrambling code

Primary scrambling code of Cell 4

– Primary CPICH TX power

Not present

– TX Diversity Indicator

FALSE

– Cell for measurement

Not present

– Inter-frequency measurement quantity

 

– Filter Coefficient

4

– Frequency quality estimate quantity

CPICH RSCP

– Inter-frequency reporting quantity

 

– UTRAN carrier RSSI

FALSE

– Frequency quality estimate

FALSE

– Non frequency related quantities

 

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CPICH Ec/No reporting indicator

FALSE

– CPICH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Measurement validity

CELL_DCH state

– Inter-frequency SET UPDATE

 

– UE autonomous update mode

On with no reporting

– CHOICE report criteria

Inter-frequency measurement reporting criteria

– Parameters required for each events

 

– Inter-frequency event identity

2b

– Threshold used frequency

-70 dBm

– W used frequency

0

– Hysteresis

2 (1 dB)

– Time to trigger

640 ms

– Reporting cell status

Within active set or within virtual active set or of the other RAT

– Maximum number of reporting cells

1

– Non used frequency parameter list

 

– Threshold non used frequency

-70 dBm

– W non-used frequency

0

DPCH compressed mode status info

Not Present

MEASUREMENT CONTROL (Step 5)

Information Element

Value/remark

Measurement Identity

3

Measurement Command

Setup

Measurement Reporting Mode

 

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Event triggered

Additional measurements list

Not Present

CHOICE measurement type

 

– inter-RAT measurement

 

– inter-RAT measurement object list

 

CHOICE Inter-RAT Cell Removal

Remove all inter-RAT cells

-Remove all inter-RAT cells

(No Data)

New inter-RAT cells (1 to <MaxCellMeas>)

– inter-RAT cell id

Id of Cell9

CHOICE Radio Access Technology

GSM

– Cell individual offset

0

– Cell selection and re-selection info

Not present

– BSIC

BSIC1

– Band indicator

GSM/DCS-1800 or GSM/PCS-1900 (dependent on band used)

– BCCH ARFCN

Value according to the GSM band under test (see 3GPP 34.123-1 table 6.5 for details on the ARFCN)

– Cell for measurement

Not present

– inter-RAT measurement quantity

 

– Measurement quantity for UTRAN quality estimate

– Intra-frequency measurement quantity

 

– Filter coefficient

0

– CHOICE mode

FDD

– Measurement quantity

CPICH RSCP

CHOICE system

GSM

– Measurement quantity

GSM carrier RSSI

– Filter coefficient

0

– BSIC verification required

Required

– inter-RAT reporting quantity

 

CHOICE system

GSM

– Observed time difference to GSM cell reporting indicator

FALSE

– GSM carrier RSSI reporting indicator

TRUE

CHOICE report criteria

 

– Inter-RAT measurements reporting criteria

 

– Parameters required for each event

 

(1 to<maxMeasEvent>)

– Inter-RAT event identity

3a

– Threshold own system

-70 dBm

– W

0

– Threshold other system

-80 dBm

– Hysteresis

2 (1 dB)

– Time to Trigger

640 ms

– Reporting cell status

Report cells within active set or within virtual active set or of the other RAT

– Maximum number of reported cells

1

Physical channel information elements

 

– DPCH compressed mode status info

If the UE requires compressed mode (refer ICS/IXIT), this IE is present and contains the IEs as follows. If the UE does not require compressed mode (refer ICS/IXIT), this IE is not present.

– TGPS reconfiguration CFN

(Current CFN+(232-TTI/10msec))mod256

– Transmission gap pattern sequence (1 to <MaxTGPS>)

– TGPSI

1

– TGPS status flag

Activate

– TGCFN

(TGPS reconfiguration CFN +6)mod 256

– TGPSI

2

– TGPS status flag

Activate

– TGCFN

(TGPS reconfiguration CFN +10)mod 256

– TGPSI

3

– TGPS status flag

Activate

– TGCFN

(TGPS reconfiguration CFN +24)mod 256

– TGPSI

4

– TGPS status flag

Activate

– TGCFN

(TGPS reconfiguration CFN +21)mod 256

MEASUREMENT REPORT (Step 7)

Information Element

Value/remark

Measurement identity

Check to see if set to 2

Measured results

– Frequency info

– UARFCN uplink

The presence of this IE is not checked

– UARFCN downlink

Check that the value of this IE is set to UARFCN for the downlink corresponding to f4

– UTRA carrier RSSI

Check to see if it is not present

– Inter-frequency cell measured results

 

– Cell Identity

Check to see if it is not present

– Cell synchronisation information

Check to see if it is not present

– Mode Specific Info

FDD

– Primary CPICH Info

 

– Primary scrambling code

Primary scrambling code for cell 4

– CPICH Ec/No

Check to see if it is not present

– CPICH RSCP

Check that measurement result is present

– Pathloss

Check to see if it is not present

Measured results on RACH

Check to see if it is not present

Additional measured results

Check to see if it is not present

Event results

Inter-frequency measurement event results,

– Inter-frequency event identity

2b

– Cell measurement event results

 

– Frequency info

– UARFCN uplink

The presence of this IE is not checked

– UARFCN downlink

Check that the value of this IE is set to UARFCN for the downlink corresponding to f4

– Primary CPICH info

 

– Primary scrambling code

Primary scrambling code of Cell 4

MEASUREMENT REPORT (Step 9)

Information Element

Value/remark

Version

Measurement identity

Check to see if set to 3

Measured Results

 

– CHOICE measurement

Check to see if set to "Inter-RAT measured results list"

– Inter-RAT measured result list

 

– CHOICE system

GSM

– Measured GSM cells

Check that measurement results for one GSM cells is included

– GSM carrier RSSI

Check that measurement result is present

CHOICE BSIC

Check it is set to verified BSIC

– inter-RAT cell id

Check that it is set to Cell id for Cell9

– Observed time difference to GSM cell

Check to see if it is not present

R99 and Rel-4 only

Measured results on RACH

Check to see if it is not present

Additional Measured results

Check to see if it is not present

Event results

Check that the IE is present

– CHOICE event result

Check that this is set to inter-RAT measurement event results

– Inter-RAT event identity

Check that this is set to 3a

– Cells to report (1 to <maxCellMeas>)

Check that <maxCellMeas> is set to 1

– CHOICE BSIC

Check that this is set to verified BSIC

– Inter-RAT cell id

Check that this is set to Cell id of Cell 9.

8.4.1.48.5 Test Requirement

1. In step 7 the UE shall send a MEASUREMENT REPORT message indicating event 2b. IE ‘Inter-frequency Cells’ in MEASUREMENT REPORT message shall contain frequency information and primary scrambling code of Cell 4.

2 In step 9 the UE shall send a MEASUREMENT REPORT message indicating event 3a with IE “Inter-RAT cell id” indicating Cell 9.

8.4.1.48a Measurement Control and Report: Combined Inter-frequency measurement for event 2b and Inter-RAT measurement, event 3a (TDD)

8.4.1.48a.1 Definition

8.4.1.48a.2 Conformance requirement

When event 2b is configured in the UE within a measurement, the UE shall:

1> if equations 1 and 2 below have been fulfilled for a time period indicated by "Time to Trigger" from the same instant, respectively for one or several non-used frequencies included for that event and for the used frequency:

2> if any of those non-used frequency is not stored in the variable TRIGGERED_2B_EVENT:

3> store the non-used frequencies that triggered the event and that were not previously stored in the variable TRIGGERED_2B_EVENT into that variable;

3> send a measurement report with IEs set as below:

4> set in "inter-frequency measurement event results":

5> "inter-frequency event identity" to "2b"; and

5> for each non-used frequency that triggered the event, beginning with the best frequency:

6> "Frequency info" to that non-used frequency; and

6> "Non frequency related measurement event results" to the "Primary CPICH info" of the best primary CPICH for FDD cells or "Primary CCPCH info" to the "Cell parameters ID" of the best primary CCPCH for TDD cells on that non-used frequency, not taking into account the cell individual offset;

4> set the IE "measured results" and the IE "additional measured results" according to TS 25.331 subclause 8.4.2, not taking into account the cell individual offset;

1> if equation 3 below is fulfilled for a non-used frequency stored in the variable TRIGGERED_2B_EVENT:

2> remove that non-used frequency from the variable TRIGGERED_2B_EVENT.

1> if equation 4 below is fulfilled for the used frequency:

2> clear the variable TRIGGERED_2B_EVENT.

Triggering conditions:

Equation 1:

The variables in the formula are defined as follows:

QNon used is the quality estimate of a non-used frequency that becomes better than an absolute threshold.

TNon used 2b is the absolute threshold that applies for this non-used frequency in that measurement.

H2b is the hysteresis parameter for the event 2b.

Equation 2:

The variables in the formula are defined as follows:

QUsed is the quality estimate of the used frequency.

TUsed 2b is the absolute threshold that applies for the used frequency in that measurement.

H2b is the hysteresis parameter for the event 2b.

Leaving triggered state condition:

Equation 3:

The variables in the formula are defined as follows:

QNon used is the quality estimate of a non-used frequency that is stored in the variable TRIGGERED_2B_EVENT.

TNon used 2b is the absolute threshold that applies for this non-used frequency in that measurement.

H2b is the hysteresis parameter for the event 2b.

Equation 4:

The variables in the formula are defined as follows:

QUsed is the quality estimate of the used frequency.

TUsed 2b is the absolute threshold that applies for the used frequency in that measurement.

H2b is the hysteresis parameter for the event 2b.

…..

When an inter-RAT measurement configuring event 3a is set up, the UE shall:

1> create a variable TRIGGERED_3A_EVENT related to that measurement, which shall initially be empty;

1> delete this variable when the measurement is released.

When event 3a is configured in the UE within a measurement, the UE shall:

1> if the other RAT is GSM, and if IE "BSIC verification required" is set to "required":

2> if equations 1 and 2 below have both been fulfilled for a time period indicated by "Time to trigger" from the same instant, respectively for the used UTRAN frequency and for one or several GSM cells that match any of the BCCH ARFCN and BSIC combinations considered in that inter-RAT measurement:

3> if the Inter-RAT cell id of any of those GSM cells is not stored in the variable TRIGGERED_3A_EVENT:

4> store the Inter-RAT cell ids of the GSM cells that triggered the event and that were not previously stored in the variable TRIGGERED_3A_EVENT into that variable.

4> send a measurement report with IEs set as below:

5> in "inter-RAT measurement event result": "inter-RAT event identity" to "3a", "CHOICE BSIC" to "verified BSIC" and "Inter-RAT cell id" to the GSM cells that triggered the event (best one first), taking into account the cell individual offset of the GSM cells;

5> "measured results" and possible "additional measured results" according to subclause 8.6.7.5 and 8.4.2, respectively, not taking into account the cell individual offset.

2> if equation 4 is fulfilled for a GSM cell whose inter-RAT cell id is stored in the variable TRIGGERED_3A_EVENT:

3> remove the inter-RAT cell id of that GSM cell from the variable TRIGGERED_3A_EVENT.

2> if equation 3 is fulfilled for the used frequency in UTRAN:

3> clear the variable TRIGGERED_3A_EVENT.

1> if the other RAT is GSM, and if IE "BSIC verification required" is set to "not required":

2> if equations 1 and 2 below have been fulfilled for a time period indicated by "Time to trigger" from the same instant, respectively for the used UTRAN frequency and for one or several BCCH ARFCNs considered in that inter-RAT measurement:

3> if any of those BCCH ARFCNs is not stored into the variable TRIGGERED_3A_EVENT:

4> store the BCCH ARFCNs that triggered the event and that were not previously stored in the variable TRIGGERED_3A_EVENT into that variable;

4> send a measurement report with IEs set as below:

5> in "inter-RAT measurement event result": "inter-RAT event identity" to "3a", "CHOICE BSIC" to "non verified BSIC" and "BCCH ARFCN" to BCCH ARFCNs that triggered the event (best one first), taking into account the cell individual offset of the GSM cells;

5> "measured results" and possible "additional measured results" according to subclause 8.6.7.5 and 8.4.2, respectively, not taking into account the cell individual offset.

2> if equation 4 is fulfilled for a BCCH ARFCN that is stored in the variable TRIGGERED_3A_EVENT:

3> remove that BCCH ARFCN from the variable TRIGGERED_3A_EVENT.

2> if equation 3 is fulfilled for the used frequency in UTRAN:

3> clear the variable TRIGGERED_3A_EVENT.

Triggering conditions:

Equation 1:

The variables in the formula are defined as follows:

QUsed is the quality estimate of the used UTRAN frequency.

TUsed is the absolute threshold that applies for the used frequency in that measurement.

H3a is the hysteresis parameter for event 3a.

Equation 2:

The variables in the formula are defined as follows:

MOther RAT is the measurement quantity for the cell of the other system.

CIOOther RAT is the cell individual offset for the cell of the other system.

TOther RAT is the absolute threshold that applies for the other system in that measurement.

H3a is the hysteresis parameter for event 3a.

Leaving triggered state conditions:

Equation 3:

The variables in the formula are defined as follows:

QUsed is the quality estimate of the used UTRAN frequency.

TUsed is the absolute threshold that applies for the used frequency in that measurement.

H3a is the hysteresis parameter for event 3a.

Equation 4:

The variables in the formula are defined as follows:

MOther RAT is the measurement quantity for the cell of the other system. MOther RAT is expressed in dBm.

CIOOther RAT is the cell individual offset for the cell of the other system.

TOther RAT is the absolute threshold that applies for the other system in that measurement.

H3a is the hysteresis parameter for event 3a.

H3c is the hysteresis parameter for event 3c.

Reference

3GPP TS 25.331 clauses 14.2.1.2, 14.3.1.1.

8.4.1.48a.3 Test Purpose

1. To confirm that the UE sends MEASUREMENT REPORT message when event 2b and 3a are configured and estimated quality of the currently used frequency is below the value of the IE "Threshold used frequency" and the estimated quality of a non-used frequency is above the value of the IE "Threshold non-used frequency". This MEASUREMENT REPORT message shall contain at least the best primary CCPCH info of the non-used frequency that triggered the event.

2. To confirm that the UE sends MEASUREMENT REPORT message when event 2b and 3a are configured and estimated quality of the currently used UTRAN frequency is below the value of the IE "Threshold own system" and the estimated quality of the other system is above the value of the IE "Threshold other system". This MEASUREMENT REPORT message shall contain the inter-RAT cell id of the GSM cell that triggered the event.

8.4.1.48a.4 Method of test

Initial Condition

System Simulator: 2 UTRAN TDD cells and 1 GSM cell. The initial configurations of the 3 cells in the SS shall follow the values indicated in the column marked "T0" in table 8.4.1.48a-1. The table is found in "Test Procedure" clause.

UE: CS-DCCH+DTCH_DCH (State 6-9) or PS-DCCH+DTCH_DCH (State 6-10) in cell 1 as specified in clause 7.4 of TS 34.108, depending on the CN domain supported by the UE.

Related ICS/IXIT statements

– Compressed mode required yes/no

Test Procedure

Table 8.4.1.48a-1 and 8.4.1.48a-2 illustrates the downlink power to be applied for the 3 cells at various time instants of the test execution. Column marked "T0" denotes the initial conditions, while columns marked "T1" and "T2" are to be applied subsequently. The exact instants on which these values shall be applied are described in the text in this clause.

Table 8.4.1.48a-1

Parameter

Unit

Cell 1

Cell 4

T0

T1

T2

T0

T1

T2

UTRA RF Channel Number

Mid Range Test Frequency

High Range Test Frequency

P-CCPCH (TDD)

dBm

-60

-80

-80

-80

-60

-80

Qrxlevmin

dBm

-115 (Note)

Note: Qrxlevmin is set to minimum value (-115) to avoid that cell trigger “out of service” condition.

Table 8.4.1.48a-2

Parameter

Unit

Cell 9

(GSM)

T0

T1

T2

Test Channel

GSM Ch.1

BCCH ARFCN

Value according to the GSM band under test (see 3GPP 34.123-1 table 6.5 for details on the ARFCN)

CELL identity

0

BSIC

BSIC 1

RF Signal Level

DBm

-90

-90

-70

The UE is initially in CELL_DCH on Cell1. UTRA cell 1 is the only cell in the active set of the UE. the SS sends two MEASUREMENT CONTROL messages to the UE, to set up inter-frequency and inter-RAT measurements respectively. Event 2b and 3a is set up in these message.

The SS then configures the UTRA cells Cell1 and Cell4 and the GSM cell Cell9 according to the values in columns "T1" in table 8.4.1.48a-1 and table 8.4.1.48a-2. As the estimate for the used frequency is below the threshold configured by the IE " Threshold used frequency " (-70dBm) and the estimate for the non-used frequency is above the threshold configured by the IE "Threshold non-used frequency" (-70dBm) then event 2b is triggered by the UE. The SS waits for the MEASUREMENT REPORT message from the UE reporting event 2b.

The SS then configures the UTRA cells Cell1 and Cell4 and the GSM cell Cell9 according to the values in columns "T2" in table 8.4.1.48a-1 and table 8.4.1.48a-2. As the estimated quality of the currently used UTRAN frequency is below the value of the IE "Threshold own system" (-70dBm) and the estimated quality of the other system is above the value of the IE "Threshold other system" (-80 dBm) then event 3a is triggered by the UE. The SS waits for a MEASUREMENT REPORT message from the UE reporting event 3a.

The SS calls for generic procedure C.3 to check that UE is in CELL_DCH state.

Expected Sequence

Step

Direction

Message

Comment

UE

SS

1

ß

The UE is brought to the CELL_DCH state in cell 1.

2

ß

MEASUREMENT CONTROL

SS sets measurement parameters for event 2b .

3

ß

MEASUREMENT CONTROL

SS commands the UE to perform Inter-RAT measurements and Inter-frequency to report event 3a and event 2b.

4

 

 

SS re-adjusts the downlink transmission power settings according to columns "T1" in table 8.4.1.48a-1 and table 8.4.1.48a-2.

5

à

MEASUREMENT REPORT

Measurement report indicating event 2b. This message should come at least 640 ms later after changing power setting of Cell 4. Layer 3 Filtering causes an additional delay.

6

 

 

SS re-adjusts the downlink transmission power settings according to columns "T2" in table 8.4.1.48a-1 and table 8.4.1.48a-2.

7

à

MEASUREMENT REPORT

Measurement report indicating event 3a. This message should come at least 640 ms later after changing power setting of Cell 9.

8

ßà

CALL C.3

If the test result of C.3 indicates that UE is in CELL_DCH state, the test passes, otherwise it fails.

9

10

Specific Message Contents

All messages indicated below shall use the same content as described in default message content, with the following exceptions:

MEASUREMENT CONTROL (Step 2)

Information Element

Value/remark

Measurement identity

2

Measurement command

Setup

Measurement reporting mode

 

– Measurement reporting transfer mode

Acknowledged mode RLC

– Periodic reporting / Event trigger reporting mode

Event trigger

Additional measurement list

Not present

CHOICE measurement type

Inter-frequency measurement

– Inter-frequency cell info list

 

– Inter-frequency cell removal

Not present

– New inter-frequency info list

 

– Inter-frequency cell id

Id of Cell 4

– Frequency Information

Frequency of Cell 4

– Cell info

 

– Cell individual offset

Default value

– Reference time difference to cell

Not present

– CHOICE mode

TDD

– Read SFN Indicator

FALSE

– Primary CCPCH Info

 

– Primary scrambling code

Primary scrambling code of Cell 4

– Primary CCPCH TX power

Not present

– TX Diversity Indicator

FALSE

– Cell for measurement

Not present

– Inter-frequency measurement quantity

 

– Filter Coefficient

4

– Frequency quality estimate quantity

PCCPCH RSCP

– Inter-frequency reporting quantity

 

– UTRAN carrier RSSI

FALSE

– Frequency quality estimate

FALSE

– Non frequency related quantities

 

– Cell synchronisation information reporting indicator

FALSE

– Cell identity reporting indicator

FALSE

– CPICH Ec/No reporting indicator

FALSE

– CPICH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Measurement validity

CELL_DCH state

– Inter-frequency SET UPDATE

 

– UE autonomous update mode

On with no reporting

– CHOICE report criteria

Inter-frequency measurement reporting criteria

– Parameters required for each events

 

– Inter-frequency event identity

2b

– Threshold used frequency

-70 dBm

– W used frequency

0

– Hysteresis

2 (1 dB)

– Time to trigger

640 ms

– Reporting cell status

Within active set or within virtual active set or of the other RAT

– Maximum number of reporting cells

1

– Non used frequency parameter list

 

– Threshold non used frequency

-70 dBm

– W non-used frequency

0

DPCH compressed mode status info

Not Present

MEASUREMENT CONTROL (Step 3)

Information Element

Value/remark

Measurement Identity

3

Measurement Command

Setup

Measurement Reporting Mode

 

– Measurement Reporting Transfer Mode

Acknowledged Mode RLC

– Periodic Reporting / Event Trigger Reporting Mode

Event triggered

Additional measurements list

Not Present

CHOICE measurement type

 

– inter-RAT measurement

 

– inter-RAT measurement object list

 

CHOICE Inter-RAT Cell Removal

Remove all inter-RAT cells

-Remove all inter-RAT cells

(No Data)

New inter-RAT cells (1 to <MaxCellMeas>)

– inter-RAT cell id

Id of Cell9

CHOICE Radio Access Technology

GSM

– Cell individual offset

0

– Cell selection and re-selection info

Not present

– BSIC

BSIC1

– Band indicator

GSM/DCS-1800 or GSM/PCS-1900 (dependent on band used)

– BCCH ARFCN

Value according to the GSM band under test (see 3GPP 34.123-1 table 6.5 for details on the ARFCN)

– Cell for measurement

Not present

– inter-RAT measurement quantity

 

– Measurement quantity for UTRAN quality estimate

– Intra-frequency measurement quantity

 

– Filter coefficient

0

– CHOICE mode

TDD

– Measurement quantity

PCCPCH RSCP

CHOICE system

GSM

– Measurement quantity

GSM carrier RSSI

– Filter coefficient

0

– BSIC verification required

Required

– inter-RAT reporting quantity

 

CHOICE system

GSM

– Observed time difference to GSM cell reporting indicator

FALSE

– GSM carrier RSSI reporting indicator

TRUE

CHOICE report criteria

 

– Inter-RAT measurements reporting criteria

 

– Parameters required for each event

 

(1 to<maxMeasEvent>)

– Inter-RAT event identity

3a

– Threshold own system

-70 dBm

– W

0

– Threshold other system

-80 dBm

– Hysteresis

2 (1 dB)

– Time to Trigger

640 ms

– Reporting cell status

Report cells within active set or within virtual active set or of the other RAT

– Maximum number of reported cells

1

MEASUREMENT REPORT (Step 5)

Information Element

Value/remark

Measurement identity

Check to see if set to 2

Measured results

Check to see if it set to “Inter-frequency measured results list”

– Frequency information

Check to see if set to Frequency of Cell 4

– UTRA carrier RSSI

Check to see if it is absent

– Inter-frequency cell measured results

– Cell measurement results

– Cell Identity

Check to see if it is absent

– Cell synchronisation information

Check to see if this IE is absent

– CHOICE mode

Check to see if set to “TDD”

– Cell parameters ID

Check to see if set to Cell parameters ID for cell 4

– Proposed TGSN

Check to see if it is absent

– Primary CCPCH RSCP

Check to see if it is present

– Pathloss

Check to see if it is absent

– Timeslot List/ISCP

Check to see if it is absent

Measured results on RACH

Check to see if it is absent

Additional measured results

Check to see if it is absent

Event results

– CHOICE event results

Check to see if set to “Inter-frequency measurement event results”

– Inter-frequency event identity

Check to see if set to “2B”

– Inter-frequency cells

– Frequency info

Check to see if set to Frequency of Cell 4

– Non-frequency related measurement event results

– CHOICE mode

Check to see if set to “TDD”

– Primary CCPCH info

– CHOICE mode

Check to see if set to “TDD”

– CHOICE mode option

Check to see if set to “1.28 Mcps TDD”

– TSTD Indicator

Check to see if set to “FALSE”

– Cell parameters ID

Check to see if set to Cell parameters ID of Cell 4

– SCTD Indicator

Check to see if set to “FALSE”

MEASUREMENT REPORT (Step 7)

Information Element

Value/remark

Version

Measurement identity

Check to see if set to 3

Measured Results

 

– CHOICE measurement

Check to see if set to "Inter-RAT measured results list"

– Inter-RAT measured result list

 

– CHOICE system

GSM

– Measured GSM cells

Check that measurement results for one GSM cells is included

– GSM carrier RSSI

Check that measurement result is present

CHOICE BSIC

Check it is set to verified BSIC

– inter-RAT cell id

Check that it is set to Cell id for Cell9

– Observed time difference to GSM cell

Check to see if it is not present

R99 and Rel-4 only

Measured results on RACH

Check to see if it is not present

Additional Measured results

Check to see if it is not present

Event results

Check that the IE is present

– CHOICE event result

Check that this is set to inter-RAT measurement event results

– Inter-RAT event identity

Check that this is set to 3a

– Cells to report (1 to <maxCellMeas>)

Check that <maxCellMeas> is set to 1

– CHOICE BSIC

Check that this is set to verified BSIC

– Inter-RAT cell id

Check that this is set to Cell id of Cell 9.

8.4.1.48a.5 Test Requirement

1. In step 7 the UE shall send a MEASUREMENT REPORT message indicating event 2b. IE ‘Inter-frequency Cells’ in MEASUREMENT REPORT message shall contain frequency information and primary scrambling code of Cell 4.

2 In step 9 the UE shall send a MEASUREMENT REPORT message indicating event 3a with IE “Inter-RAT cell id” indicating Cell 9.

8.4.1.49 Measurement Control and Report: Intra-frequency measurement for event 1J

8.4.1.49.1 Definition

8.4.1.49.2 Conformance requirement

When an intra-frequency measurement configuring event 1j is set up, the UE shall:

1> create a variable TRIGGERED_1J_EVENT related to that measurement, which shall initially be empty;

1> delete this variable when the measurement is released.

When event 1J is configured in the UE, the UE shall:

1> if "Measurement quantity" is "pathloss" and Equation 1 below is fulfilled for one or more primary CPICHs, or if "Measurement quantity" is "CPICH Ec/N0" or "CPICH RSCP", and Equation 2 below is fulfilled for one or more primary CPICHs, for each of these primary CPICHs:

2> if all required reporting quantities are available for that cell; and

2> if the equations have been fulfilled for a time period indicated by "Time to trigger", and if the primary CPICH that is better is not included in the E-DCH active set but included in DCH active set and the other primary CPICH is any of the primary CPICHs included in the E-DCH active set, and if that first primary CPICH is not included in the "cells triggered" in the variable TRIGGERED_1J_EVENT:

3> include that primary CPICH in the "cells recently triggered" in the variable TRIGGERED_1J_EVENT.

1> if the value of "Replacement activation threshold" for this event is less than or equal to the current number of cells in the E-DCH active set or equal to 0 and if any primary CPICHs are stored in the "cells recently triggered" in the variable TRIGGERED_1J_EVENT:

2> if "Reporting interval" for this event is not equal to 0:

3> if the IE "Periodical reporting running" in the variable TRIGGERED_1J_EVENT is set to FALSE:

4> start a timer for with the value of "Reporting interval" for this event and set the IE "Periodical reporting running" in the variable TRIGGERED_1J_EVENT to TRUE.

3> set "sent reports" for that primary CPICH in the variable TRIGGERED_1J_EVENT to 1.

2> send a measurement report with IEs set as below:

3> set in "intra-frequency measurement event results": "Intrafrequency event identity" to "1J"; and

3> include in "cell measurement event results" all entries of the "cells recently triggered" in the variable TRIGGERED_1J_EVENT not in the E-DCH active set but included in DCH active set as well as the "primary CPICH info" of all the primary CPICHs in the E-DCH active set for which the measured value is worse (i.e. greater for pathloss and less for the other measurement quantities) than the one of the entry in "cell recently triggered" that has the best measured value taking into account their cell individual offset. The "primary CPICH info" for those cells shall be ordered according to their measured value taking into account their cell individual offset, beginning with the best cell to the worst one;

3> set the IE "measured results" and the IE "additional measured results" according to subclause 8.4.2, not taking into account the cell individual offset for each cell.

2> …

Reference

3GPP TS 25.331 clause 14.1.2.7

8.4.1.49.3 Test Purpose

1. To confirm that the UE sends MEASUREMENT REPORT message if event 1J is configured, and the number of cells in the E-DCH active set is greater than or equal to ‘Replacement activation threshold’ parameter, and if the primary CPICH that is not included in the E-DCH active set but included in the DCH active set becomes better than any of the primary CPICHs included in the E-DCH active set.

2. To confirm that the UE does not send MEASUREMENT REPORT message indicating event 1J if the number of cells in the active E-DCH set is less than ‘Replacement activation threshold’ parameter, even if the primary CPICH that is not included in the E-DCH active set but included in the DCH active set becomes better than any of the primary CPICHs included in the E-DCH active set.

3. To confirm that the UE does not send MEASUREMENT REPORT message indicating event 1J, even if the cell that is not in the DCH active set becomes better than any of the primary CPICHs included in the E-DCH active set.

4. To confirm that the UE stops periodic reporting of event 1J when the “sent reports” in variable TRIGGERED_1J_EVENT is greater than “Amount of reporting”.

8.4.1.49.4 Method of Test

Initial Condition

System Simulator: 3 cells – The initial configuration of the 3 cells in the SS shall follow the values indicated in the column marked “T0” in table 8.4.1.49-1. The table is found in “Test Procedure” clause

UE: PS-DCCH +DTCH_HS-DSCH +DTCH_E-DCH (state 6-18) under condition A12 in Cell 1 as specified in clause 7.4 of TS 34.108

Related ICS/IXIT statement(s)

– UE supports FDD

– UE supports HS-PDSCH

– UE supports E-DPDCH

Test Procedure

Table 8.4.1.49-1 illustrates the downlink power to be applied for the 3 cells at various instants of the test execution. Columns marked “T0” denotes the initial conditions, while “T1”, “T2”, “T3”, “T4”, and “T5” are to be applied subsequently. The exact instants on which these values shall be applied are described in the text in this clause.

Table 8.4.1.49-1

Parameter

Unit

Cell 1

T0

T1

T2

T3

T4

T5

UTRA RF Channel Number

Ch.1

CPICH Ec (FDD)

dBm/3.84Mhz

-60

-60

-60

-60

-66

-66

Parameter

Unit

Cell 2

T0

T1

T2

T3

T4

T5

UTRA RF Channel Number

Ch.1

CPICH Ec (FDD)

dBm/3.84Mhz

-80

-60

-72

-72

-78

-60

Parameter

Unit

Cell 3

T0

T1

T2

T3

T4

T5

UTRA RF Channel Number

Ch.1

CPICH Ec (FDD)

dBm/3.84Mhz

-80

-60

-78

-66

-60

-60

The UE is in the CELL_DCH state and has a radio bearer mapped on E-DCH and HS-DSCH established with active E-DCH transmission and HS-DSCH reception.

SS configures its downlink transmission power settings according to columns "T1" in table 8.4.1.49-1. UE shall be triggered to transmit a MEASUREMENT REPORT message, which includes the primary scrambling code for cell 2.

SS performs a soft handover by sending ACTIVE SET UPDATE on the DL DCCH. The UE shall respond with ACTIVE SET UPDATE COMPLETE on the uplink DCCH and include Cell 2 and Cell 3 in the DCH active set.

SS configures its downlink transmission power settings according to columns "T2" in table 8.4.1.49-1.Setup event 1J by MEASUREMENT CONTROL with IE. ‘Replacement activation threshold’ set to 1.

SS configures itself according to the values in columns "T3" by increasing the power of Cell 3 (but not above Cell 1 and outside the reporting range for Cell 1). There shall be no measurement reports generated for this condition.

SS configures itself according to the values in columns "T4" to trigger event 1J and waits for 10 seconds. There shall be 2 measurement reports reporting event 1J. The "cell measurement event" of the measurement report contains the information of primary CPICH for Cell 3 and Cell 1.

SS removes Cell 2 from the DCH active set by sending ACTIVE SET UPDATE on the DL DCCH. The UE shall respond with ACTIVE SET UPDATE COMPLETE on the uplink DCCH

SS configures itself according to the values in the columns "T5". Cell 2 is better than Cell 1, however the UE shall not send a MEASUREMENT REPORT message indicating event 1J as the event is only triggered for cells in the DCH active set.

The SS then sends MEASUREMENT CONTROL message to the UE to modify the earlier configured 1J measurement. Now IE ‘Replacement activation threshold’ is set to 2. MEASUREMENT CONTROL messages contain only those IEs that are modified and the UE shall continue to use current values of parameters that are not modified. Add Cell 2 to the DCH active set by sending ACTIVE SET UPDATE on the DL DCCH. The UE shall respond with ACTIVE SET UPDATE COMPLETE. Now Cell 2 is better than Cell 1 and is in the DCH active set. However the UE shall not send MEASUREMENT REPORT message indicating 1J because the number of cells in the E-DCH active set is less than parameter "Replacement Activation Threshold". The SS then sends MEASUREMENT CONTROL message to set the IE ‘Replacement activation threshold’ back to 1 and wait 10 seconds. There shall be 2 measurement reports reporting event 1J. The “cell measurement event” of the measurement report contains the information of primary CPICH for Cell 2,3 and 1.

SS calls for generic procedure C.3 to check that UE is in CELL_DCH state.

Expected Sequence

Step

Direction

Message

Comment

UE

SS

0

UE is initially in CELL_DCH state in cell 1.

0a

SS configures its downlink transmission power settings according to columns "T1" in table 8.4.1.49-1

0b

MEASUREMENT REPORT

See specific message contents for this message.

0c

SS configures its downlink transmission power settings according to columns "T2" in table 8.4.1.49-1

1

ACTIVE SET UPDATE

SS command the UE to add Cell 2 and Cell 3 in the DCH active set.

2

ACTIVE SET UPDATE COMPLETE

3

MEASUREMENT CONTROL

Event 1J is setup. IE "Replacement activation threshold" is set to 1.

4

SS re-adjusts the downlink transmission power settings according to columns "T3" in table 8.4.1.49-1.

5

Check for 10 seconds, the UE shall not send MEASUREMENT REPORT message.

6

SS re-adjusts the downlink transmission power settings according to columns "T4" in table 8.4.1.49-1.

7

MEASUREMENT REPORT

Event 1J is triggered. The UE report contains the information of primary CPICH for Cell 3 and Cell 1.

8

MEASUREMENT REPORT

The UE shall send a second report. Check for 10 seconds, the UE shall send no further measurement reports

9

ACTIVE SET UPDATE

SS command the UE to remove Cell 2 from the DCH active set

10

ACTIVE SET UPDATE COMPLETE

11

SS re-adjusts the downlink transmission power settings according to columns "T5" in table 8.4.1.49-1.

12

Check for 10 seconds, the UE shall not send MEASUREMENT REPORT MESSAGE (Cell 2 is not in the active DCH set)

13

MEASUREMENT CONTROL

Event 1J is setup to set IE "Replacement activation threshold" is set to 2.

14

ACTIVE SET UPDATE

SS commands the UE to add Cell 2 back to the DCH active set

15

ACTIVE SET UPDATE COMPLETE

16

Check for 10 seconds, the UE shall not send MEASUREMENT REPORT MESSAGE (number of cells in the E-DCH active set is less than threshold)

17

MEASUREMENT CONTROL

Event 1J is setup to set IE "Replacement activation threshold" back to 1.

18

MEASUREMENT REPORT

Event 1J is triggered. The UE report contains the information of primary CPICH for cell3, Cell 2 and Cell 1.

19

MEASUREMENT REPORT

The UE shall send second report. Check for 10 seconds, the UE shall send no further measurement reports

20



CALL C.3

If the test result of C.3 indicates that UE is in CELL_DCH state, the test passes, otherwise it fails.

Specific Message Contents

All messages indicated below shall use the same content as described in TS 34.108 clause 9, with the following exceptions:

MEASUREMENT REPORT (Step 0b)

Information Element

Value/remark

Message Type

Integrity check info

– Message authentication code

This IE is checked to see if it is present. The value is compared against the XMAC-I value computed by SS. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I.

– RRC Message sequence number

This IE is checked to see if it is present. The value is used by SS to compute the XMAC-I value.

Measurement identity

1

Measured Results

– Intra-frequency measured results

Check to see if measurement results for 3 cells are included (the order in which the different cells are reported is not important)

– Cell measured results

– Cell Identity

Checked that this IE is absent

– Cell synchronisation information

Checked that this IE is absent

– Primary CPICH info

– Primary scrambling code

Refer to clause titled "Default settings for cell No.1 (FDD)" in clause 6.1 of TS 34.108

– CPICH Ec/N0

Checked that this IE is absent

– CPICH RSCP

Checked that this IE is present

– Pathloss

Checked that this IE is absent

– Cell measured results

– Cell Identity

Checked that this IE is absent

– Cell synchronisation information

Checked that this IE is present and includes IE COUNT-C-SFN frame difference

– Primary CPICH info

– Primary scrambling code

Refer to clause titled "Default settings for cell No.2 (FDD)" in clause 6.1 of TS 34.108

– CPICH Ec/N0

Checked that this IE is absent

– CPICH RSCP

Checked that this IE is present

– Pathloss

Checked that this IE is absent

– Cell measured results

– Cell Identity

Checked that this IE is absent

– Cell synchronisation information

Checked that this IE is present and includes IE COUNT-C-SFN frame difference

– Primary CPICH info

– Primary scrambling code

Refer to clause titled "Default settings for cell No.3 (FDD)" in clause 6.1 of TS 34.108

– CPICH Ec/N0

Checked that this IE is absent

– CPICH RSCP

Checked that this IE is present

– Pathloss

Checked that this IE is absent

Measured results on RACH

Checked that this IE is absent

Additional measured results

Checked that this IE is absent

Event results

– Intra-frequency measurement event results

– Intra-frequency event identity

1a

– Cell measurement event results

– Primary CPICH info

The UE may include either or both of the following cells.(the order in which the different cells are reported is not important)

– Primary scrambling code

Refer to clause titled "Default settings for cell No.2 (FDD)" in clause 6.1 of TS 34.108

– Primary scrambling code

Refer to clause titled "Default settings for cell No.3 (FDD)" in clause 6.1 of TS 34.108

ACTIVE SET UPDATE (Step 1)

Information Element

Value/remark

Version

Radio link addition information

– Primary CPICH info

– Primary scrambling code

Primary scrambling code of Cell 2

– Downlink DPCH info for each RL

– CHOICE MODE

FDD

– Primary CPICH usage for channel estimation

Primary CPICH may be used

– DPCH frame offset

Calculated value from Cell synchronisation information

– Secondary CPICH info

Not Present

– DL channelisation code

This IE is repeated for all existing downlink DPCHs allocated to the UE on Cell 2

– Secondary scrambling code

1

– Spreading factor

Reference to TS34.108 clause 6 Parameter Set

– Code number

For each DPCH, assign the same code number in the current code given in cell 1

– Scrambling code change

Not Present

– TPC combination index

0

– Closed loop timing adjustment mode

Not Present

– Primary CPICH info

– Primary scrambling code

Primary scrambling code of Cell 3

– Downlink DPCH info for each RL

– CHOICE MODE

FDD

– Primary CPICH usage for channel estimation

Primary CPICH may be used

– DPCH frame offset

Calculated value from Cell synchronisation information

– Secondary CPICH info

Not Present

– DL channelisation code

This IE is repeated for all existing downlink DPCHs allocated to the UE on Cell 3

– Secondary scrambling code

1

– Spreading factor

Reference to TS34.108 clause 6 Parameter Set

– Code number

For each DPCH, assign the same code number in the current code given in cell 1

– Scrambling code change

Not Present

– TPC combination index

0

– SSDT cell identity

Not Present

– Closed loop timing adjustment mode

Not Present

MEASUREMENT CONTROL (Steps 3 and 17)

Information Element

Value/remark

Measurement Identity

1

Measurement Command

Setup

Measurement Reporting Mode

– Measurement Report Transfer Mode

Acknowledged mode RLC

– Periodical Reporting/Event Trigger Reporting Mode

Periodical reporting

CHOICE Measurement type

Intra-frequency measurement

– Intra-frequency measurement

– Intra-frequency cell info list

– CHOICE intra-frequency cell removal

Remove no intra-frequency cells

– New intra-frequency cells

– Intra-frequency cell-id

Id of Cell 2

– Cell info

– Cell individual offset

0 (0dB)

– Reference time difference to cell

Not Present

– Read SFN number

FALSE

– CHOICE mode

FDD

– Primary CPICH info

– Primary scrambling code

Primary scrambling code of Cell 2

– Primary CPICH Tx power

Not Present

– TX Diversity indicator

FALSE

– Cell Selection and Re-selection Info

Not Present

– Intra-frequency cell-id

Id of Cell 3

– Cell info

– Cell individual offset

0 (0dB)

– Reference time difference to cell

Not Present

– Read SFN number

FALSE

– CHOICE mode

FDD

– Primary CPICH info

– Primary scrambling code

Primary scrambling code of Cell 3

– Primary CPICH Tx power

Not Present

– TX Diversity indicator

FALSE

– Cell Selection and Re-selection Info

Not Present

– Cells for measurement

– Intra-frequency cell id list

Set to id of cell 1, 2 and 3

– Intra-frequency measurement quantity

– Filter coefficient

0

– Measurement quantity

CPICH RSCP

– Intra-frequency reporting quantity

– Reporting quantities for active set cells

– Cell synchronization information reporting indicator

FALSE

– Cell Identity reporting indicator

FALSE

– CPICH Ec/N0 reporting indicator

FALSE

– CPICH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting quantities for monitored set cells

– Cell synchronization information reporting indicator

FALSE

– Cell Identity reporting indicator

FALSE

– CPICH Ec/N0 reporting indicator

FALSE

– CPICH RSCP reporting indicator

TRUE

– Pathloss reporting indicator

FALSE

– Reporting quantities for detected set cells

Not Present

– Reporting cell status

Not Present

– Measurement validity

Not Present

– CHOICE report criteria

Intra-frequency measurement reporting criteria

– Parameters required for each event

– Intra-frequency event identity

1J

– Hysteresis

0

– Replacement activation threshold

1

– Time to trigger

200 ms

– Amount of reporting

2

– Reporting interval

500 ms

– Reporting cell status

– Report cells within active set and/or monitored set cells on used frequency

– Maximum number of reported cells

3

DPCH Compressed mode status info

Not Present

MEASUREMENT REPORT (Step 7 and 8)

Information Element

Value/remark

Measurement identity

1

Measured Results

– CHOICE measurement

Check to see if set to "Intra-frequency measured results list"

– Intra-frequency measurement results

Check to see if measurement results for 3 cells are included

– Cell measured results

– Cell Identity

Check to see if it is absent

– Cell synchronisation information

Check to see if this IE is absent

– Primary CPICH Info

– Primary Scrambling Code

Check to see if it’s the same code for cell 3

– CPICH Ec/No

Check to see if this IE is absent

– CPICH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

– Cell measured results

– Cell Identity

Check to see if it is absent

– Cell synchronisation information

Check to see if this is absent

– Primary CPICH Info

– Primary Scrambling Code

Check to see if it’s the same code for cell 1

– CPICH Ec/No

Check to see if this IE is absent

– CPICH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

– Cell measured results

– Cell Identity

Check to see if it is absent

– Cell synchronisation information

Check to see if this is absent

– Primary CPICH Info

– Primary Scrambling Code

Check to see if it’s the same code for cell 2

– CPICH Ec/No

Check to see if this IE is absent

– CPICH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

Additional Measured results

Check to see if this IE is absent

Event results

Check to see if set to “Intra-frequency measurement event results“

– Intra-frequency event identity

Check to see if set to “1J”

– Cell measurement event results

– Primary CPICH info

Check to see if set to “Primary scrambling code of Cell 3

– Primary CPICH info

Check to see if set to “Primary scrambling code of Cell 1

ACTIVE SET UPDATE (Step 9)

Information Element

Value/remark

Version

Radio link removal information

– Primary CPICH info

– Primary scrambling code

Primary scrambling code of Cell 2

MEASUREMENT CONTROL (step 13)

Use the same message as defined for steps 3 and 17 with the exception of the following IE

Information Element

Value/remark

CHOICE report criteria

Intra-frequency measurement reporting criteria

– Parameters required for each event

– Intra-frequency event identity

1J

– Hysteresis

0

– Replacement activation threshold

2

– Time to trigger

200 ms

– Amount of reporting

2

– Reporting interval

500 ms

– Reporting cell status

– Report cells within active set and/or monitored set cells on used frequency

– Maximum number of reported cells

3

ACTIVE SET UPDATE (Step 14)

Information Element

Value/remark

Version

Radio link addition information

– Primary CPICH info

– Primary scrambling code

Primary scrambling code of Cell 2

– Downlink DPCH info for each RL

– CHOICE MODE

FDD

– Primary CPICH usage for channel estimation

Primary CPICH may be used

– DPCH frame offset

Calculated value from Cell synchronisation information

– Secondary CPICH info

Not Present

– DL channelisation code

This IE is repeated for all existing downlink DPCHs allocated to the UE on Cell 2

– Secondary scrambling code

1

– Spreading factor

Reference to TS34.108 clause 6 Parameter Set

– Code number

For each DPCH, assign the same code number in the current code given in cell 1

– Scrambling code change

Not Present

– TPC combination index

0

– Closed loop timing adjustment mode

Not Present

– TPC combination index

0

– SSDT cell identity

Not Present

– Closed loop timing adjustment mode

Not Present

MEASUREMENT REPORT (Step 18 and 19)

Information Element

Value/remark

Measurement identity

1

Measured Results

Check to see if this IE is present

– CHOICE measurement

Check to see if set to "Intra-frequency measured results list"

– Intra-frequency measurement results

Check to see if measurement results for 3 cells are included (the order in which cells 2 and 3 are reported is not important)

– Cell measured results

– Cell Identity

Check to see if it is absent

– Cell synchronisation information

Check to see if this IE is absent

– Primary CPICH Info

– Primary Scrambling Code

Check to see if it’s the same code for cell 2

– CPICH Ec/No

Check to see if this IE is absent

– CPICH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

– Cell measured results

– Cell Identity

Check to see if it is absent

– Cell synchronisation information

Check to see if this is absent

– Primary CPICH Info

– Primary Scrambling Code

Check to see if it’s the same code for cell 3

– CPICH Ec/No

Check to see if this IE is absent

– CPICH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

– Cell measured results

– Cell Identity

Check to see if it is absent

– Cell synchronisation information

Check to see if this is absent

– Primary CPICH Info

– Primary Scrambling Code

Check to see if it’s the same code for cell 1

– CPICH Ec/No

Check to see if this IE is absent

– CPICH RSCP

Check to see if this IE is present

– Pathloss

Check to see if this IE is absent

Measured Results on RACH

Check to see if this IE is absent

Additional Measured results

Check to see if this IE is absent

Event results

Check to see if set to “Intra-frequency measurement event results“

– Intra-frequency event identity

Check to see if set to “1J”

– Cell measurement event results

Check to see if measurement results for 3 cells are included (the order in which cells 2 and 3 are reported is not important)

– Primary CPICH info

Check to see if set to “Primary scrambling code of Cell 3”

– Primary CPICH info

Check to see if set to “Primary scrambling code of Cell 2

– Primary CPICH info

Check to see if set to “Primary scrambling code of Cell 1

8.4.1.49.5 Test Requirement

In steps 7, 8, 18 and 19 the UE shall send a MEASUREMENT REPORT indicating event 1J. For steps 7 and 8 the IE ‘Cell measurement event results’ in the MEASUREMENT REPORT message should contain primary scrambling codes of Cell 3 and Cell 1. For steps 18 and 19 the IE ‘Cell measurement event results’ in the MEASUREMENT REPORT message should contain primary scrambling codes of Cell 2 and Cell 1.

In step 16 the UE shall not send a MEASUREMENT REPORT message.

In step 12 the UE shall not send a MEASUREMENT REPORT message.

In steps 7 and 8 the UE shall send 2 measurement reports only.

8.4.1.50 Measurement reporting when moving from CELL_PCH to CELL_FACH

8.4.1.50.1 Definition and applicability

All UEs which support FDD and HS-PDSCH in CELL_PCH and URA_PCH.

8.4.1.50.2 Conformance requirement

In CELL_PCH or URA_PCH state, the UE shall:

1> if the measurement reporting is not initiated according to subclause 8.5.40:

2> first perform the cell update procedure according to subclause 8.3.1, using the cause "uplink data transmission", in order to transit to CELL_FACH state; and then

2> transmit a MEASUREMENT REPORT message on the uplink DCCH when the reporting criteria stored in variable MEASUREMENT_IDENTITY are fulfilled for any ongoing UE positioning measurement which is being performed in the UE.

For FDD, the UE in CELL_PCH state shall:

1> if variable H_RNTI is set:

2> if the measurement reporting is initiated according to subclause 8.5.40:

3> set the IE "measurement identity" to "16";

3> not set the IE "measured results";

3> include the IE "measured results on RACH";

3> if an event triggered traffic volume measurement has been configured:

4> if the TCTV is larger than the threshold in the IE "Reporting threshold" for a traffic volume measurement stored in the MEASUREMENT_IDENTITY variable and that traffic volume measurement has "measurement identity" equal to 4, "Traffic volume event identity" equal to "4a", "Measurement validity" equal to "all states" or "all states except CELL_DCH":

5> set the IE "Traffic volume event identity" to "4a";

  1. and then transmit the MEASUREMENT REPORT message on the uplink DCCH using AM RLC; when the MEASUREMENT REPORT message has been submitted to lower layers for transmission the procedure ends.

When the IE "HS-DSCH paging system information" is included in System Information Block type 5 or System Information Block type 5bis and the UE is in CELL_PCH or URA_PCH state, the UE shall:

1> set the variable HS_DSCH_RECEPTION_GENERAL to TRUE;

1> if variable H_RNTI and variable C_RNTI are set:

2> if the UE is in CELL_PCH state:

3> use the value of the variable H_RNTI as UE identity in the HS-SCCH reception procedure in the physical layer for DCCH or DTCH reception; and

3> for BCCH reception perform HS-DSCH reception procedures by listening to the first indexed HS-SCCH code listed in the IE "HS-SCCH channelisation code" with "BCCH specific H-RNTI" as received in IE "HS-DSCH common system information" from System Information Block type 5 or System Information Block type 5bis.

3> if the UE detects the value of the variable H_RNTI in the HS-SCCH reception procedure:

4> initiate the measurement report procedure as specified in subclause 8.4.2:

5> if the UE has an uplink RLC PDU on RB1 or upwards to transmit:

6> move to CELL_FACH;

6> stop timer T319 if it is running.

3> if the UE has uplink RLC data PDU or uplink RLC control PDU on RB1 or upwards to transmit:

4> initiate the measurement report procedure as specified in subclause 8.4.2:

4> move to CELL_FACH state;

4> stop timer T319 if it is running.

Reference

3GPP TS 25.331 clause 8.5.40 and 8.4.2

8.4.1.50.3 Test purpose

1. To confirm that the UE performs measurements reporting on SRB2 when moving from Cell PCH state to Cell FACH state when HS-DSCH is configured with dedicated H-RNTI

2. To confirm that the UE performs measurements reporting with a cell update procedure when moving from Cell PCH state to Cell FACH state when HS-DSCH is configured with no dedicated H-RNTI.

8.4.1.50.4 Method of test

Initial Condition

System Simulator: 1 cell

UE: CELL_FACH state as specified in clause 7.4 of TS 34.108, with a valid H-RNTI

The UE is registered in both CS and PS domains.

Test Procedure

The UE is in the CELL_FACH state with HS-DSCH reception enabled. The SS transmits a PHYSICAL CHANNEL RECONFIGURATION message with IE "RRC State Indicator" set to "CELL_PCH " and assigns a dedicated H_RNTI. The UE shall reply with PHYSICAL CHANNEL RECONFIGURATION COMPLETE message and move to CELL_PCH state. The SS transmits a UE CAPABILITY ENQUIRY message. This triggers the UE to move to CELL_FACH state and transmit a MEASUREMENT REPORT and UE CAPABILITY INFORMATION message on the uplink DCCH using RLC-AM mode. SS completes the procedure by transmitting a UE CAPABILITY INFORMATION CONFIRM message. The UE shall remain in CELL_FACH state.

The SS then transmits a PHYSICAL CHANNEL RECONFIGURATION message with IE "RRC State Indicator" set to "CELL_PCH " and with no dedicated H_RNTI. The UE shall reply with PHYSICAL CHANNEL RECONFIGURATION COMPLETE message and move to CELL_PCH state. The SS transmits a PAGING TYPE 1 message which includes a matched identifier and the optional IE "CN originated page to connected mode UE" The UE then moves to CELL_FACH state and transmits a CELL UPDATE message to the SS on the uplink CCCH, with the IE "Cell update cause" set to value "uplink data transmission" and IE ‘Measurement Results on RACH’ containing the measured CPICH RSCP for cell 1 . After receiving such a message, SS transmits a CELL UPDATE CONFIRM message on downlink DCCH mapped to HS-DSCH. Then the UE shall transmit an UTRAN MOBILITY INFORMATION CONFIRM message on the uplink DCCH to acknowledge the receipt of the new UE identities. The UE shall stay in CELL_FACH state and transmit an INITIAL DIRECT TRANSFER message using AM RLC on DCCH.

Expected sequence

Step

Direction

Message

Comment

UE

SS

1

The UE is brought to CELL_FACH state.

2

PHYSICAL CHANNEL RECONFIGURATION

IE "RRC State Indicator" set to "CELL_PCH" and dedicated H-RNTI

3

PHYSICAL CHANNEL RECONFIGURATION COMPLETE

UE moves to CELL_PCH state.

4

UE CAPABILITY ENQUIRY

5

MEASUREMENT REPORT

This message shall contain IE "Measured results on RACH" reporting the measured CPICH RSCP for cell 1 and the "Measurement identity" to "16

6

UE CAPABILITY INFORMATION

The order of MEASUREMENT REPORT and UE CAPABILITY INFORMATION is not important.

6a

UE CAPABILITY INFORMATION CONFIRM

7

PHYSICAL CHANNEL RECONFIGURATION

IE "RRC State Indicator" set to "CELL_PCH" and no dedicated H-RNTI

8

PHYSICAL CHANNEL RECONFIGURATION COMPLETE

UE moves to CELL_PCH state.

9

PAGING TYPE 1

Includes Matched identifier and optional IE “CN originated page to connected mode UE"

10

CELL UPDATE

The UE moves to CELL FACH state and transmit this message which is set to "uplink data transmission" in IE "Cell update cause". This message shall contain IE "Measured results on RACH" reporting the measured CPICH RSCP for cell 1

11

CELL UPDATE CONFIRM

See message content .

12

UTRAN MOBILITY INFORMATION CONFIRM

13

INITIAL DIRECT TRANSFER

Response to the paging message sent in step 9

14



CALL C.2

If the test result of C.2 indicates that UE is in CELL_FACH state, the test passes, otherwise it fails.

Specific Message Contents

System Information Block type 11 (Step 1)

Use the same System Information Block Type 11 message as found in clause 6.1.0b of TS 34.108, with the following exceptions:

Information Element

Value/remark

Intra-frequency reporting quantity for RACH reporting

– SFN-SFN observed time difference reporting indicator

No report

– CHOICE mode

FDD

– Measurement quantity

CPICH RSCP

– Maximum number of reported cells on RACH

Current cell

PHYSICAL CHANNEL RECONFIGURATION (Step 2)

Use the same message sub-type found in TS 34.108 clause 9, which is entitled "Packet to CELL_FACH from CELL_FACH in PS", with the following exceptions:

Information Element

Value/remark

New C-RNTI

‘1010 1010 1010 1010’

New H-RNTI

Set to an arbitrary string different from ‘1010 1010 1010 1010’

RRC State Indicator

CELL_PCH

UTRAN DRX cycle length coefficient

3

UE CAPABILITY ENQUIRY (Step 4)

Use the same message sub-type found in TS 34.108 clause 9.1.

PAGING TYPE 1 (Step 9)

Information Element

Value/remark

Message Type

Paging record list

Only 1 entry

Paging record

– CHOICE Used paging identity

UTRAN identity

– U-RNTI

– SRNC Identity

Set to the previously assigned SRNC identity

– S-RNTI

Set to previously assigned S-RNTI

– CN originated page to connected mode UE

-Paging cause

Terminating Conversational Call

-CN domain identity

CS Domain

-Paging record type identifier

Set to "TMSI (GSM-MAP)/P-TMSI" for UEs supporting GSM-MAP core network type or "TMSI (DS-41)" for UEs supporting ANSI-41 core network type.

BCCH modification info

Not Present

MEASUREMENT REPORT (Step 5)

Information Element

Value/remark

Message Type

Integrity check info

– Message authentication code

This IE is checked to see if it is present. The value is compared against the XMAC-I value computed by SS. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I.

– RRC Message sequence number

This IE is checked to see if it is present. The value is used by SS to compute the XMAC-I value.

Measurement identity

16

Measured Results

NOT PRESENT

Measured results on RACH

Checked that this IE is present

Additional measured results

Checked that this IE is absent

Event results

Checked that this IE is absent

GSM OTD reference cell

Checked that this IE is absent

Inter-RAT cell info indication

Checked that this IE is absent

UE CAPABILITY INFORMATION (Step 6)

Use the same message sub-type found in TS 34.108 clause 9.

UE CAPABILITY INFORMATION CONFIRM (Step 6a)

Use the same message sub-type found in TS 34.108 clause 9.1.

PHYSICAL CHANNEL RECONFIGURATION (Step 7)

Use the same message sub-type found in TS 34.108 clause 9, which is entitled "Packet to CELL_FACH from CELL_FACH in PS", with the following exceptions:

Information Element

Value/remark

New H-RNTI

NOT PRESENT

RRC State Indicator

CELL_PCH

UTRAN DRX cycle length coefficient

3

CELL UPDATE (Step 10)

The same message found in TS 34.108 clause 9 shall be transmitted by the UE on the uplink CCCH, with the exception of the following IEs:

Information Element

Value/remark

U-RNTI

– SRNC Identity

Check to see if set to ‘0000 0000 0001’

– S-RNTI

Check to see if set to ‘0000 0000 0000 0000 0001’

Cell Update Cause

Check to see if set to ‘uplink data transmission’

Measured results on RACH

Checked that this IE is present

CELL UPDATE CONFIRM (Step 11)

Use the same message sub-type found in TS 34.108 clause 9, with the following exceptions:

Information Element

Value/remark

New H-RNTI

Set to an arbitrary string different from ‘1010 1010 1010 1010’

INITIAL DIRECT TRANSFER (Step13) – for UEs supporting GSM-MAP core networks

Check to see if the same message type found in TS 34.108 clause 9 is received, with the following exceptions:

Information Element

Value/remark

CN domain identity

CS domain

Intra Domain NAS Node Selector

– CHOICE version

R99

— CHOICE CN type

GSM

— CHOICE Routing basis

Local(P)TMSI

—- Routing parameter

This bit string is set to bits b14 through b23 of the TMSI.

The TMSI consists of 4 octets (32bits). This can be represented by a string of bits numbered from b0 to b31, with bit b0 being the least significant.

The "Routing parameter" bit string consists of bits b14 through b23 of the TMSI.

The first/ leftmost/ most significant bit of the bit string contains bit b23 of the TMSI

— Entered parameter

Not checked

NAS message

Not checked

INITIAL DIRECT TRANSFER (Step13) – for UEs supporting ANSI-41 core networks

Information Element

Value/remark

CN domain identity

CS Domain

Intra Domain NAS Node Selector

– CHOICE version

ANSI-41: Bitstring(14), all bits set to 0

NAS message

Not checked

START

Not checked

Measured results on RACH

Not checked

8.4.1.50.5 Test requirement

After step 2, UE shall transmit a PHYSICAL CHANNEL RECONFIGURATION COMPLETE message and move to CELL_PCH state.

After step 4, the UE shall move to CELL_FACH state and transmits a RRC STATUS message and MEASUREMENT REPORT message on SRB2 containing the IE "Measured results on RACH" reporting the measured CPICH RSCP for cell 1 and the IE "Measurement identity" set to "16".

After step 7, the UE shall transmit a PHYSICAL CHANNEL RECONFIGURATION COMPLETE message and move to CELL_PCH state.

After step 10, the UE shall move to CELL_FACH state and initiate a cell update procedure and transmits a CELL UPDATE message on RACH containing the IE "Measured results on RACH" reporting the measured CPICH RSCP for cell 1.

After step 12, the UE shall transmit a UTRAN MOBILITY INFORMATION CONFIRM message on the uplink DCCH using AM RLC.

After step 13, UE shall transmit a INITIAL DIRECT TRANSFER message to SS using AM RLC on DCCH.

8.4.1.51 Measurement Control and Report: Inter-frequency measurement for events 2C for CSG cells

8.4.1.51.1 Definition

Test to verify the UE can report the 2c events for CSG cells.

8.4.1.51.2 Conformance requirement

1. Event 2c: The estimated quality of a non-used frequency is above a certain threshold

When an inter-frequency measurement configuring event 2c is set up, the UE shall:

1> create a variable TRIGGERED_2C_EVENT related to that measurement, which shall initially be empty;

1> delete this variable when the measurement is released.

When event 2c is configured in the UE within a measurement, the UE shall:

1> if equation 1 below has been fulfilled for one or several non-used frequencies included for that event during the time "Time to trigger":

2> if any of those non-used frequencies is not stored in the variable TRIGGERED_2C_EVENT:

2> if the CSG virtual active set has been updated, since the last measurement report for this event associated with CSG measurement, for any of those non-used frequency which are stored in the variable TRIGGERED_2C_EVENT:

3> store the non-used frequencies that triggered the event and that were not previously stored in the variable TRIGGERED_2C_EVENT into that variable;

3> send a measurement report with IEs set as below:

4> set in "inter-frequency measurement event results":

5> "inter-frequency event identity" to "2c"; and

5> for each non-used frequency that triggered the event, beginning with the best frequency:

6> "Frequency info" to that non-used frequency; and

6> "Non frequency related measurement event results" to the "Primary CPICH info" of the best primary CPICH for FDD cells or "Primary CCPCH info" to the "Cell parameters ID" of the best primary CCPCH for TDD cells on that non-used frequency, not taking into account the cell individual offset.

4> include in IE "Inter-frequency measured results list" the measured results for each non-used frequency that triggered the event, not taking into account the cell individual offset;

4> set the IE "additional measured results" according to subclause 8.4.2 not taking into account the cell individual offset.

1> if equation 1 below has been fulfilled but the CSG virtual active set is updated for a non-used frequency included for that event:

2> restart evaluation of this event for this frequency.

1> if equation 2 below is fulfilled for a non-used frequency stored in the variable TRIGGERED_2C_EVENT:

2> remove that non-used frequency from the variable TRIGGERED_2C_EVENT.

Triggering condition:

Equation 1:

The variables in the formula are defined as follows:

QNon used is the quality estimate of a non-used frequency that becomes better than an absolute threshold.

TNon used 2c is the absolute threshold that applies for this non-used frequency in that measurement.

H2c is the hysteresis parameter for the event 2c.

Leaving triggered state condition:

Equation 2:

The variables in the formula are defined as follows:

QNon used is the quality estimate of a non-used frequency stored in the variable TRIGGERED_2C_EVENT.

TNon used 2c is the absolute threshold that applies for this non-used frequency in that measurement.

H2c is the hysteresis parameter for the event 2c.

Reference

1: 3GPP TS 25.331 clause 14.2.1.3.

8.4.1.51.3 Test purpose

1. To confirm that the UE sends MEASUREMENT REPORT message when event 2c is configured and a non-used frequency is above a certain threshold. This MEASUREMENT REPORT message shall contain at least the best primary CPICH info (for FDD) on the non-used frequency that triggered the event and the best primary CPICH info is of the CSG cell present in CSG virtual active set.

2. To confirm that event 2C triggered for a non-used frequency when another CSG cell becomes stronger than the CSG cell in CSG virtual active set.

3. To confirm that evaluation of event 2C is re-started when CSG virtual active set is updated.

8.4.1.51.4 Method of test

Initial Condition

System Simulator:

4 cells: Cell 1, cell 4, cell 6 and cell5 are used. Column marked "T0" in table 8.4.1.51-1 found in "Test Procedure" clause denotes the initial power conditions.

The CSG id of the Cell 5 is 2 and cell 6 is 3. Cell 4 does not broadcast CSG ID.

Cell1 is on f1.

Cell 4, cell 6 and cell 5 are on f2.

User Equipment:

The UE’s Allowed CSG List contains CSG Ids 2 & 3. UE’s operator CSG list is empty.

The UE is PS-DCCH+DTCH_DCH (state 6-10) or CS-DCCH+DTCH_DCH (state 6-9) or PS+CS-DCCH+DTCH_DCH (state 6-14) in cell 1 as specified in clause 7.4 of TS 34.108, depending on the CN domain(s) supported by the UE.

Related ICS/IXIT statement(s)

– UE supports FDD

– UE supports compressed mode

– UE supports inter-frequency SI acquisition for HO.

Test Procedure

Table8.4.1.51-1 illustrates the downlink power to be applied for the 4 cells.

Table 8.4.1.51-1

Parameter

Unit

Cell 1

Cell4

Cell 5

Cell 6

Test Channel

1

2

2

T0

T1

T2

T0

T1

T2

T0

T1

T2

T0

T1

T2

CPICH_Ec

dBm/3.84MHz

-65

-65

-65

-75

-55

OFF

-75

-65

-65

OFF

OFF

-55

The UE is initially in CELL_DCH and has a radio bearer with the cell 1.

At instant T0, the downlink is according to what is shown in table 8.4.1.51-1. The SS then sets up an intra-frequency measurement (event 1c) and an inter-frequency CSG measurement (event 2c), by sending separate MEASUREMENT CONTROL messages to the UE. Configuration of event 1c is important for the UE to construct CSG VAS active set.

The SS configures then compressed mode (if required), to prepare the UE for inter-frequency measurements, by sending a PHYSICAL CHANNEL RECONFIGURATION message on DCCH using AM-RLC. The UE shall answer with a PHYSICAL CHANNEL RECONFIGURATION COMPLETE message.

At instant T1, the downlink power is changed according to what is shown in table 8.4.1.51-1. The UE shall thus send a MEASUREMENT REPORT with 2c event to the SS. The MEASUREMENT REPORT message contains PSC of Cell-5 (which is a CSG cell) and not PSC of Cell-4 (which is a non-CSG cell), since event 2c is configured for CSG cells.

At instant T2, the downlink power is changed according to what is shown in table 8.4.1.51-1. The UE shall thus send a MEASUREMENT REPORT with 2c event to the SS with PSC of Cell-6. This happens due to Cell-6 being stronger CSG cell than Cell-5. However, this measurement report is not sent before summation of time-to-triggers of both event 1c and 2c.

Expected sequence

Step

Direction

Message

Comment

UE

SS

1

The SS maintains the power of the three cells according to column T0 in table 8.4.1.51 -1

2

MEASUREMENT CONTROL

The SS configures an intra-frequency measurement to the UE. Event 1c is configured.

3

MEASUREMENT CONTROL

The SS configures an inter-frequency measurement to the UE. Event 2c is configured. If Compressed Mode not required (refer ICS/IXIT) go to step 6

4

PHYSICAL CHANNELRECONFIGURATION

The SS instructs UE to begin compressed mode operation.

(for FDD only)

5

PHYSICAL CHANNELRECONFIGURATION COMPLETE

(for FDD only)

6

The SS re-adjusts the downlink transmission power settings of the cells according to columns "T1" in table8.4.1.51 -1.

7

MEASUREMENT REPORT

The UE sends a measurement report including the measured PSC for cell 5 and event 2c.

8

The SS re-adjusts the downlink transmission power settings of the cells according to columns "T2" in table 8.4.1.51-1.

9

MEASUREMENT REPORT

The UE sends a measurement report including the PSC for cell 6 and event 2c.

Check that this measurement report should not come before 10 sec (i.e., 5000ms TTT of event 1c + 5000ms TTT of event 2c)

Specific Message Contents

MEASUREMENT CONTROL (Step 2)

Use the same message sub-type found in TS 34.108, clause 9, with the following exceptions

Information Element

Value/remark

Measurement identity

1

Measurement command

Measurement reporting mode

– Measurement reporting transfer mode

– Periodic reporting / Event trigger reporting mode

Setup

Acknowledged mode RLC

Event trigger

CHOICE measurement type

Intra-frequency measurement

– intra-frequency measurement

– Intra-frequency cell info list

– Cells for measurement

– Intra-frequency cell id

– Cell info

– Cell individual offset

– Reference time difference to cell

– Read SFN number

– CHOICE mode

– Primary CPICH info

– Primary scrambling code

– Primary CPICH Tx power

– TX Diversity indicator

– Intra-frequency measurement quantity

– Filter Coefficient

– CHOICE mode

– FDD

– Measurement quantity

Set to same code as used for cell 1

0 (0dB)

Not Present

FALSE

FDD

100

Not Present

FALSE

0

CPICH RSCP

– CHOICE report criteria

Intra-frequency measurement reporting criteria

– Intra-frequency measurement reporting criteria

– Parameters required for each events

– Intra-frequency event identity

1c

– Hysteresis

4 (2dB)

– Replacement activation threshold

3

– Time to trigger

5000 ms

– Amount of reporting

16

– Reporting interval

4000ms

– Reporting cell status

Not present

MEASUREMENT CONTROL (Step 3)

Information Element

Value/remark

Measurement identity

2

Measurement command

Measurement reporting mode

– Measurement reporting transfer mode

– Periodic reporting / Event trigger reporting mode

Additional measurement list

Setup

Unacknowledged Mode RLC

Event trigger

Not present

CHOICE measurement type

Inter-frequency measurement

– inter-frequency measurement

– Inter-frequency cell info list

– Inter-frequency cell removal

Not Present

– New inter-frequency cells

– Inter-frequency cell id

4

– Frequency info

Set to same code as used for cell 4

– cell info

– Cell individual offset

– Reference time difference to cell

Not present

Not present

– Read SFN indicator

FALSE

– CHOICE mode

-FDD

– Primary CPICH info

– Primary Scrambling Code

– Primary CPICH Tx power

– TX Diversity Indicator

– Inter-frequency cell id

– Frequency info

– cell info

– Cell individual offset

– Reference time difference to cell

– Read SFN indicator

– CHOICE mode

-FDD

– Primary CPICH info

– Primary Scrambling Code

– Primary CPICH Tx power

– TX Diversity Indicator

– Inter-frequency cell id

– Frequency info

– cell info

– Cell individual offset

– Reference time difference to cell

– Read SFN indicator

– CHOICE mode

-FDD

– Primary CPICH info

– Primary Scrambling Code

– Primary CPICH Tx power

– TX Diversity Indicator

– Cell for measurement

– CSG Inter-frequency cell info

– CSG Frequency info

– Frequency info

– CSG Inter-frequency cell info for the frequency

– CSG cell info list

– CHOICE mode

– Start PSC

– Number of PSCs

– Inter-frequency SI Acquisition

– Inter-frequency measurement quantity

– Filter Coefficient

– Frequency quality estimate quantity

– Inter-frequency reporting quantity

– UTRAN Carrier RSSI

– Frequency quality estimate

– Non frequency related quantities

– Cell synchronisation information reporting indicator

– Cell identity reporting indicator

– CPICH Ec/No reporting indicator

– CPICH RSCP reporting indicator

– Pathloss reporting indicator

Set to same code as used for cell 4

Not present

FALSE

5

Frequency of Cell 5

Not present

Not present

FALSE

Primary scrambling code of Cell 5

Not present

FALSE

6

Frequency of Cell 6

Not present

Not present

FALSE

Primary scrambling code of Cell 6

Not present

FALSE

Not present

Frequency of Cell 4, 5, 6

FDD

300

100

Not present

4

CPICH RSCP

FALSE

FALSE

FALSE

FALSE

FALSE

TRUE

FALSE

– Measurement validity

CELL_DCH state

– inter-frequency set update

– UE autonomous update mode

On with no reporting

– CHOICE report criteria

– Inter-frequency measurement reporting criteria

– Parameters required for each event

– Inter-frequency event identity

2c

– Hysteresis

– Time to trigger

– Reporting cell status

2(1dB)

5000 mSec

Not present

– Parameters required for each non-used frequency

– Threshold non used frequency

-70 dBm

– W non used frequency

DPCH compressed mode status info

0

Not present

PHYSICAL CHANNEL RECONFIGURATION (Step 4)

Use the same message sub-type found in Annex A, which is entitled "(Packet to CELL_DCH from CELL_DCH in PS)", with the following exceptions in the IE(s) concerned:

Information Element

Value/remark

Version

Downlink information common for all radio links

– Downlink DPCH info common for all RL

– Timing Indication

Maintain

– Downlink DPCH power control information

– DPC mode

0 (Single)

– CHOICE Mode

FDD

– Power offset PPilot-DPDCH

0

– DL rate matching restriction information

Not present

– Spreading factor

Refer to the parameter set in TS 34.108

– Fixed or flexible position

Flexible

– TFCI existence

TRUE

– Number of bits for Pilot bits (SF=128, 256)

Not present

– DPCH compressed mode info

– TGPSI

1

– TGPS status flag

Activate

– TGCFN

(Current CFN+(256 – TTI/10msec)) mod 256

– Transmission gap pattern sequence configuration parameters

– TGMP

FDD Measurement

– TGPRC

Infinity

– TGSN

4

– TGL1

7

– TGL2

Not Present

– TGD

Undefined

– TGPL1

3

– TGPL2

Not Present

R99 and Rel-4 only

– RPP

Mode 0

– ITP

Mode 0

– CHOICE UL/DL mode

UL and DL or DL only or UL only depending on UE capability

– Downlink compressed mode method

SF/2

– Uplink compressed mode method

SF/2 or Not present depending on UE capability

– Downlink frame type

A

– DeltaSIR1

20 (2.0)

– DeltaSIRAfter1

10 (1.0)

– DeltaSIR2

Not present

– DeltaSIRAfter2

Not present

– N identify abort

Not present

– T Reconfirm abort

Not present

– TX diversity mode

None

– SSDT information

Not present

R99 and Rel-4 only

– Default DPCH offset value

Not present

MEASUREMENT REPORT (Step 7)

Information Element

Value/remark

Measurement identity

Check to see if set to 2

Measured results

Check to see if it is absent

Additional measured results

Check to see if it is absent

Event results

Inter-frequency measurement event results,

– CHOICE event result

– Inter-frequency measurement event results

– Inter-frequency event identity

2c

– Inter-frequency cells

– Frequency info

Set to same code as used for cell 5

– Non frequency related measurement event results

– CHOICE mode

– FDD

– Primary CPICH info

– Primary scrambling code

Set to same code as used for cell 5

MEASUREMENT REPORT (Step 9)

Information Element

Value/remark

Measurement identity

Check to see if set to 2

Measured results

Check to see if it is absent

Additional measured results

Check to see if it is absent

Event results

Inter-frequency measurement event results,

– CHOICE event result

– Inter-frequency measurement event results

– Inter-frequency event identity

2c

– Inter-frequency cells

– Frequency info

Frequency of cell 6

– Non frequency related measurement event results

– CHOICE mode

– FDD

– Primary CPICH info

– Primary scrambling code

Set to same code as used for cell 6

8.4.1.51.5 Test requirement

1. At step 7, the UE sends 2c event to the SS. IE "Inter-frequency measurement event results" in this message shall contain frequency information and primary scrambling code of Cell 5.

2. At step 9, the UE sends 2c event to the SS. IE "Inter-frequency measurement event results " in this message shall contain frequency information and primary scrambling code of Cell 6. This message shall only be sent after 10 secs of SS adjusting its power as per Step 8.

8.4.1.52 Measurement Control and Report: Inter-frequency measurement for events 2B for CSG cells

8.4.1.52.1 Definition

Test to verify the UE can report the 2b events for CSG cells.

8.4.1.52.2 Conformance requirement

1: Event 2b: The estimated quality of the currently used frequency is below a certain threshold and the estimated quality of a non-used frequency is above a certain threshold.

When an inter-frequency measurement configuring event 2b is set up, the UE shall:

1> create a variable TRIGGERED_2B_EVENT related to that measurement, which shall initially be empty;

1> delete this variable when the measurement is released.

When event 2b is configured in the UE within a measurement, the UE shall:

1> if equations 1 and 2 below have been fulfilled for a time period indicated by "Time to Trigger" from the same instant, respectively for one or several non-used frequencies included for that event and for the used frequency:

2> if any of those non-used frequency is not stored in the variable TRIGGERED_2B_EVENT:

2> if the CSG virtual active set has been updated, since the last measurement report for this event associated with CSG measurement, for any of those non-used frequency which are stored in the variable TRIGGERED_2B_EVENT:

3> store the non-used frequencies that triggered the event and that were not previously stored in the variable TRIGGERED_2B_EVENT into that variable;

3> send a measurement report with IEs set as below:

4> set in "inter-frequency measurement event results":

5> "inter-frequency event identity" to "2b"; and

5> for each non-used frequency that triggered the event, beginning with the best frequency:

6> "Frequency info" to that non-used frequency; and

6> "Non frequency related measurement event results" to the "Primary CPICH info" of the best primary CPICH for FDD cells or "Primary CCPCH info" to the "Cell parameters ID" of the best primary CCPCH for TDD cells on that non-used frequency, not taking into account the cell individual offset.

4> include in IE "Inter-frequency measured results list" the measured results for each non-used frequency that triggered the event, not taking into account the cell individual offset;

4> set the IE "additional measured results" according to subclause 8.4.2, not taking into account the cell individual offset.

1> if this equations 1 and 2 below have been fulfilled but the CSG virtual active set is updated for a frequency included for that event:

2> restart evaluation of this event for this frequency.

1> if equation 3 below is fulfilled for a non-used frequency stored in the variable TRIGGERED_2B_EVENT:

2> remove that non-used frequency from the variable TRIGGERED_2B_EVENT.

1> if equation 4 below is fulfilled for the used frequency:

2> clear the variable TRIGGERED_2B_EVENT.

Triggering conditions:

Equation 1:

The variables in the formula are defined as follows:

QNon used is the quality estimate of a non-used frequency that becomes better than an absolute threshold.

TNon used 2b is the absolute threshold that applies for this non-used frequency in that measurement.

H2b is the hysteresis parameter for the event 2b.

Equation 2:

The variables in the formula are defined as follows:

QUsed is the quality estimate of the used frequency.

TUsed 2b is the absolute threshold that applies for the used frequency in that measurement.

H2b is the hysteresis parameter for the event 2b.

Leaving triggered state condition:

Equation 3:

The variables in the formula are defined as follows:

QNon used is the quality estimate of a non-used frequency that is stored in the variable TRIGGERED_2B_EVENT.

TNon used 2b is the absolute threshold that applies for this non-used frequency in that measurement.

H2b is the hysteresis parameter for the event 2b.

Equation 4:

The variables in the formula are defined as follows:

QUsed is the quality estimate of the used frequency.

TUsed 2b is the absolute threshold that applies for the used frequency in that measurement.

H2b is the hysteresis parameter for the event 2b.

Reference

1: 3GPP TS 25.331 clause 14.2.1.2.

8.4.1.52.3 Test purpose

1. To confirm that the UE sends MEASUREMENT REPORT message when event 2B is configured and estimated quality of the currently used frequency is below the value of the IE "Threshold used frequency" and the estimated quality of a non-used frequency is above the value of the IE "Threshold non-used frequency". This MEASUREMENT REPORT message shall contain at least the best primary CPICH info (for FDD) on the non-used frequency that triggered the event and the best primary CPICH info is of the CSG cell present in CSG virtual active set.

2. To confirm that event 2B triggered for a non-used frequency when another CSG cell becomes stronger than the CSG cell in CSG virtual active set.

3. To confirm that evaluation of event 2B is re-started when CSG virtual active set is updated.

8.4.1.52.4 Method of test

Initial Condition

System Simulator:

4 cells: Cell 1, cell 4, cell 6 and cell 5 are used. Column marked "T0" in table 8.4.1.52-1 found in "Test Procedure" clause denotes the initial power conditions.

The CSG id of the Cell5 is 2 and cell 6 is 3. Cell 4 does not broadcast CSG ID.

Cell1 is on f1.

Cell 4, cell 6 and cell 5 are on f2.

User Equipment:

The UE’s Allowed CSG List contains CSG Ids 2 & 3. UE’s operator CSG list is empty.

The UE is PS-DCCH+DTCH_DCH (state 6-10) or CS-DCCH+DTCH_DCH (state 6-9) or PS+CS-DCCH+DTCH_DCH (state 6-14) in cell 1 as specified in clause 7.4 of TS 34.108, depending on the CN domain(s) supported by the UE.

Related ICS/IXIT statement(s)

– UE supports FDD

– UE supports compressed mode

– UE supports inter-frequency SI acquisition for HO.

Test Procedure

Table 8.4.1.52-1 illustrates the downlink power to be applied for the 4 cells.

Table 8.4.1.52-1

Parameter

Unit

Cell 1

Cell4

Cell 5

Cell 6

Test Channel

1

2

2

T0

T1

T2

T0

T1

T2

T0

T1

T2

T0

T1

T2

CPICH_Ec

dBm/3.84MHz

-55

-75

-75

-55

-55

OFF

-65

-65

-65

OFF

OFF

-55

The UE is initially in CELL_DCH and has a radio bearer with the cell 1.

At instant T0, the downlink is according to what is shown in table 8.4.1.52-1. The SS then sets up an intra-frequency measurement (event 1c) and an inter-frequency CSG measurement (event 2b), by sending separate MEASUREMENT CONTROL messages to the UE. Configuration of event 1c is important for the UE to construct CSG VAS active set.

The SS configures then compressed mode (if required), to prepare the UE for inter-frequency measurements, by sending a PHYSICAL CHANNEL RECONFIGURATION message on DCCH using AM-RLC. The UE shall answer with a PHYSICAL CHANNEL RECONFIGURATION COMPLETE message.

At instant T1, the downlink power is changed according to what is shown in table 8.4.1.52-1. The UE shall thus send a MEASUREMENT REPORT with 2b event to the SS. The MEASUREMENT REPORT message contains PSC of Cell-5 (which is a CSG cell) and not PSC of Cell-4 (which is a non-CSG cell), since event 2b is configured for CSG cells.

At instant T2, the downlink power is changed according to what is shown in table 8.4.1.52-1. The UE shall thus send a MEASUREMENT REPORT with 2b event to the SS with PSC of Cell-6. This happens due to Cell-6 being stronger CSG cell than Cell-5. However, this measurement report is not sent before summation of time-to-triggers of both event 1c and 2b.

Expected sequence

Step

Direction

Message

Comment

UE

SS

1

The SS maintains the power of the cells according to column T0 in table 8.4.1.52-1

2

MEASUREMENT CONTROL

The SS configures an intra-frequency measurement to the UE. Event 1c is configured.

3

MEASUREMENT CONTROL

The SS configures an inter-frequency CSG measurement to the UE. Event 2b is configured. If Compressed Mode not required (refer ICS/IXIT) go to step 6

4

PHYSICAL CHANNELRECONFIGURATION

The SS instructs UE to begin compressed mode operation.

(for FDD only)

5

PHYSICAL CHANNELRECONFIGURATION COMPLETE

(for FDD only)

6

The SS re-adjusts the downlink transmission power settings of the cells according to columns "T1" in table 8.4.1.52-1.

7

MEASUREMENT REPORT

The UE sends a measurement report including the PSC for cell 5 and event 2b.

8

The SS re-adjusts the downlink transmission power settings of the cells according to columns "T2" in table 8.4.1.52-1.

9

MEASUREMENT REPORT

The UE sends a measurement report including the PSC for cell 6 and event 2b.

Check that this measurement report should not come before 10 sec (i.e., 5000ms TTT of event 1c + 5000ms TTT of event 2b)

Specific Message Contents

MEASUREMENT CONTROL (Step 2)

Use the same message sub-type found in TS 34.108, clause 9, with the following exceptions

Information Element

Value/remark

Measurement identity

1

Measurement command

Measurement reporting mode

– Measurement reporting transfer mode

– Periodic reporting / Event trigger reporting mode

Setup

Acknowledged mode RLC

Event trigger

CHOICE measurement type

Intra-frequency measurement

– intra-frequency measurement

– Intra-frequency cell info list

– Cells for measurement

– Intra-frequency cell id

– Cell info

– Cell individual offset

– Reference time difference to cell

– Read SFN number

– CHOICE mode

– Primary CPICH info

– Primary scrambling code

– Primary CPICH Tx power

– TX Diversity indicator

– Intra-frequency measurement quantity

– Filter Coefficient

– CHOICE mode

– FDD

– Measurement quantity

Set to same code as used for cell 1

0 (0dB)

Not Present

FALSE

FDD

100

Not Present

FALSE

0

CPICH RSCP

– CHOICE report criteria

Intra-frequency measurement reporting criteria

– Intra-frequency measurement reporting criteria

– Parameters required for each events

– Intra-frequency event identity

1c

– Hysteresis

4 (2dB)

– Replacement activation threshold

3

– Time to trigger

5000 ms

– Amount of reporting

16

– Reporting interval

4000ms

– Reporting cell status

Not present

MEASUREMENT CONTROL (Step 3)

Information Element

Value/remark

Measurement identity

2

Measurement command

Measurement reporting mode

– Measurement reporting transfer mode

– Periodic reporting / Event trigger reporting mode

Additional measurement list

Setup

Unacknowledged Mode RLC

Event trigger

Not present

CHOICE measurement type

Inter-frequency measurement

– inter-frequency measurement

– Inter-frequency cell info list

– Inter-frequency cell removal

Not Present

– New inter-frequency cells

– Inter-frequency cell id

4

– Frequency info

Set to same code as used for cell 4

– cell info

– Cell individual offset

– Reference time difference to cell

Not present

Not present

– Read SFN indicator

FALSE

– CHOICE mode

-FDD

– Primary CPICH info

– Primary Scrambling Code

– Primary CPICH Tx power

– TX Diversity Indicator

– Inter-frequency cell id

– Frequency info

– cell info

– Cell individual offset

– Reference time difference to cell

– Read SFN indicator

– CHOICE mode

-FDD

– Primary CPICH info

– Primary Scrambling Code

– Primary CPICH Tx power

– TX Diversity Indicator

– Inter-frequency cell id

– Frequency info

– cell info

– Cell individual offset

– Reference time difference to cell

– Read SFN indicator

– CHOICE mode

-FDD

– Primary CPICH info

– Primary Scrambling Code

– Primary CPICH Tx power

– TX Diversity Indicator

– Cell for measurement

– CSG Inter-frequency cell info

– CSG Frequency info

– Frequency info

– CSG Inter-frequency cell info for the frequency

– CSG cell info list

– CHOICE mode

– Start PSC

– Number of PSCs

– Inter-frequency SI Acquisition

– Inter-frequency measurement quantity

– Filter Coefficient

– Frequency quality estimate quantity

– Inter-frequency reporting quantity

– UTRAN Carrier RSSI

– Frequency quality estimate

– Non frequency related quantities

– Cell synchronisation information reporting indicator

– Cell identity reporting indicator

– CPICH Ec/No reporting indicator

– CPICH RSCP reporting indicator

– Pathloss reporting indicator

Set to same code as used for cell 4

Not present

FALSE

5

Frequency of Cell 5

Not present

Not present

FALSE

Primary scrambling code of Cell 5

Not present

FALSE

6

Frequency of Cell 6

Not present

Not present

FALSE

Primary scrambling code of Cell 6

Not present

FALSE

Not present

Frequency of Cell 4, 5, 6

FDD

300

100

Not present

4

CPICH RSCP

FALSE

FALSE

FALSE

FALSE

FALSE

TRUE

FALSE

– Measurement validity

CELL_DCH state

– inter-frequency set update

– UE autonomous update mode

On with no reporting

– CHOICE report criteria

– Inter-frequency measurement reporting criteria

– Parameters required for each event

– Inter-frequency event identity

2b

– Threshold used frequency

-70dBm

– W used frequency

0.0

– Hysteresis

– Time to trigger

– Reporting cell status

2(1dB)

5000 mSec

Not present

– Parameters required for each non-used frequency

– Threshold non used frequency

-70 dBm

– W non used frequency

DPCH compressed mode status info

0

Not present

PHYSICAL CHANNEL RECONFIGURATION (Step 4)

Use the same message sub-type found in Annex A, which is entitled "(Packet to CELL_DCH from CELL_DCH in PS)", with the following exceptions in the IE(s) concerned:

Information Element

Value/remark

Downlink information common for all radio links

– Downlink DPCH info common for all RL

– Timing Indication

Maintain

– Downlink DPCH power control information

– DPC mode

0 (Single)

– CHOICE Mode

FDD

– Power offset PPilot-DPDCH

0

– DL rate matching restriction information

Not present

– Spreading factor

Refer to the parameter set in TS 34.108

– Fixed or flexible position

Flexible

– TFCI existence

TRUE

– Number of bits for Pilot bits (SF=128, 256)

Not present

– DPCH compressed mode info

– TGPSI

1

– TGPS status flag

Activate

– TGCFN

(Current CFN+(256 – TTI/10msec)) mod 256

– Transmission gap pattern sequence configuration parameters

– TGMP

FDD Measurement

– TGPRC

Infinity

– TGSN

4

– TGL1

7

– TGL2

Not Present

– TGD

Undefined

– TGPL1

3

– TGPL2

Not Present

– RPP

Mode 0

– ITP

Mode 0

– CHOICE UL/DL mode

UL and DL or DL only or UL only depending on UE capability

– Downlink compressed mode method

SF/2

– Uplink compressed mode method

SF/2 or Not present depending on UE capability

– Downlink frame type

A

– DeltaSIR1

20 (2.0)

– DeltaSIRAfter1

10 (1.0)

– DeltaSIR2

Not present

– DeltaSIRAfter2

Not present

– N identify abort

Not present

– T Reconfirm abort

Not present

– TX diversity mode

None

– SSDT information

Not present

– Default DPCH offset value

Not present

MEASUREMENT REPORT (Step 7)

Information Element

Value/remark

Measurement identity

Check to see if set to 2

Measured results

Check to see if it is absent

Additional measured results

Check to see if it is absent

Event results

Inter-frequency measurement event results,

– CHOICE event result

– Inter-frequency measurement event results

– Inter-frequency event identity

2b

– Inter-frequency cells

– Frequency info

Set to same code as used for cell 5

– Non frequency related measurement event results

– CHOICE mode

– FDD

– Primary CPICH info

– Primary scrambling code

Set to same code as used for cell 5

MEASUREMENT REPORT (Step 9)

Information Element

Value/remark

Measurement identity

Check to see if set to 2

Measured results

Check to see if it is absent

Additional measured results

Check to see if it is absent

Event results

Inter-frequency measurement event results,

– CHOICE event result

– Inter-frequency measurement event results

– Inter-frequency event identity

2b

– Inter-frequency cells

– Frequency info

Frequency of cell 6

– Non frequency related measurement event results

– CHOICE mode

– FDD

– Primary CPICH info

– Primary scrambling code

Set to same code as used for cell 6

8.4.1.52.5 Test requirement

1. At step 7, the UE sends 2b event to the SS. IE "Inter-frequency measurement event results" in this message shall contain frequency information and primary scrambling code of Cell 5.

2. At step 9, the UE sends 2b event to the SS. IE "Inter-frequency measurement event results" in this message shall contain frequency information and primary scrambling code of Cell 6. This message shall only be sent after 10 secs of SS adjusting its power as per Step 8.

8.4.1.53 Measurement Control and Report: Application layer measurement

8.4.1.53.1 Definition

8.4.1.53.2 Conformance requirement

25.331[8] clause 8.4.1 and clause 8.4.2 RRC MEASUREMENT procedure.

Upon reception of a MEASUREMENT CONTROL message the UE shall perform actions specified in TS 25.331 subclause 8.4.1 and 8.4.2 unless otherwise specified below.

The UE shall:

1> read the IE "Measurement command";

1> if the IE "Measurement command" has the value "setup":

2> store this measurement in the variable MEASUREMENT_IDENTITY according to the IE "measurement identity", first releasing any previously stored measurement with that identity if that exists;

2> for measurement type "Application layer measurement configuration":

3> if the UE is not in CELL_DCH or CELL_FACH state:

4> the UE behaviour is unspecified.

3> else:

4> forward the content of the IE "Application layer measurement configuration" to upper layers.

25.331[8] subclause 8.4.1 TP2

1> if any configured application layer measurement configuration is to be released, the UE shall:

2> inform upper layers to clear the stored "Application layer measurement configuration".

25.331[8] subclause 8.4.2 TP1

Measurement Report

In CELL_DCH state, the UE shall:

1> transmit a MEASUREMENT REPORT message on the uplink DCCH when the reporting criteria stored in variable MEASUREMENT_IDENTITY are met for any ongoing measurements that are being performed in the UE.

The reporting criteria are fulfilled if either:

– a periodic MEASUREMENT REPORT message shall be sent according to the IE "Periodical Reporting Criteria"; or

– an event in stored IE "Measurement reporting criteria" was triggered. Events and triggering of reports for different measurement types are described in detail in clause 14.

– a "Container for application layer measurement reporting" is received from upper layers.

For the measurement, which triggered the MEASUREMENT REPORT message, the UE shall:

1> if measurement type "Application layer measurement configuration" is configured and the UE is in CELL_DCH state:

2> set the IE "Application layer measurement reporting" to include measurements according to the IE "Application layer measurement configuration" of that measurement stored in variable MEASUREMENT_IDENTITY.

The UE shall:

1> transmit the MEASUREMENT REPORT message on the uplink DCCH using either AM or UM RLC according to the stored IE "measurement reporting mode" associated with the measurement identity that triggered the report.

25.331[8] clause 6.3 Signalling Radio Bearers TP1

The Radio Bearers (RB) available for transmission of RRC messages are defined as "signalling radio bearers" and are specified in the following. The UE and UTRAN shall select the signalling radio bearers for RRC messages using RLC-TM, RLC-UM or RLC-AM on the DCCH and CCCH, according to the following:

– Signalling radio bearer RB0 shall be used for all messages sent on the CCCH (UL: RLC-TM, DL: RLC-UM).

– Signalling radio bearer RB1 shall be used for all messages sent on the DCCH, when using RLC unacknowledged mode (RLC-UM).

– Signalling radio bearer RB2 shall be used for all messages sent on the DCCH, when using RLC acknowledged mode (RLC-AM), except for the RRC messages carrying higher layer (NAS) signalling and the MEASUREMENT REPORT message carrying the IE "Application layer measurement reporting".

– Signalling radio bearer RB3 and optionally Signalling radio bearer RB4 shall be used for the RRC messages carrying higher layer (NAS) signalling and sent on the DCCH in RLC acknowledged mode (RLC-AM), as specified in subclauses 8.1.8., 8.1.9 and 8.1.10.

– Signalling radio bearer RB4 shall be used for UE INFORMATION RESPONSE message and the MEASUREMENT REPORT message carrying the IE "Application layer measurement reporting".

– Additionally, RBs whose identities shall be set between 5 and 32 may be used as signalling radio bearer for the RRC messages on the DCCH sent in RLC transparent mode (RLC-TM).

– RRC messages on the SHCCH are mapped either on RACH or on the USCH in the uplink using TM and either on FACH or on the DSCH using RLC-UM. These messages are only specified for TDD mode.

– RRC messages on the MCCH are mapped on FACH using RLC-UM. The transport channel configuration for MCCH is indicated on BCCH. For this signalling radio bearer no identity is applied.

– RRC messages on the MSCH are mapped on FACH using RLC-UM. The transport channel configuration for MSCH is indicated on MCCH. For this signalling radio bearer no identity is applied.

Reference 3GPP TS 25.331[8] clauses 8.4.1.3 and 8.4.2 and 6.3

8.4.1.53.3 Test Purpose

1. To confirm that UE in CELL_DCH, if receives Application layer measurement configuration, it shall forward the Application layer measurement report received from the upper layer in the uplink DCCH, and to confirm that UE transmit Application layer measurement over SRB4.

2. To confirm that UE won’t forward the Application layer measurement report received from the upper layer unless it’s configured.

8.4.1.53.4 Method of test

Initial Condition

Radio environment: Static Channel: Normal propagation condition described in 34.108 [9] clause 5.2.2, ideal channel quality to ensure reliable data transfer in air interface;

System Simulator: 1 cell

UE:

– The UE shall be operated under normal test conditions.

– Registered Idle Mode on PS (state3).

Test Procedure

The UE is initially in Registered Idle Mode on PS (state3), and then the procedure P5 specified in TS 34.108 [9] clause7 is called to make the UE to transit to CELL_DCH. To execute procedure P5, all specific message contents are used as specified in TS 34.108[9] clause 9 with the exception in step 3. For step3, the message of the same type titled “RRC CONNECTION SETUP message: UM (Transition to CELL_DCH or in CELL_FACH)” including Signalling RB information to setup titled (AM DCCH for NAS_DT Low priority) under condition A2.

Cause UE upper layer to send an APPLICATION LAYER MEASUREMENT REPORT to UE RRC layer.

SS is not expected to receive an APPLICATION LAYER MEASUREMENT REPORT from UE because APPLICATION LAYER MEASUREMENT is not setup previously;

SS sends MEASUREMENT CONTROL message to UE to setup APPLICATION LAYER MEASUREMENT;

Cause UE upper layer to provide 3 APPLICATION LAYER MEASUREMENT REPORTs to UE RRC layer successively every 5 seconds, the lengths of which are 1000, 4000 and 8000 bytes respectively;

SS is expected to receive 3 APPLICATION LAYER MEASUREMENT REPORTs forwarded by UE within less than 30 seconds.

SS sends MEASUREMENT CONTROL message to UE to release APPLICATION LAYER MEASUREMENT;

Cause UE upper layer to provide one APPLICATION LAYER MEASUREMENT REPORTs, the length of which are 1000 bytes;

SS is not expected to receive any the APPLICATION LAYER MEASUREMENT REPORT due to the measurement is released.

Expected Sequence

Step

Direction

Message(Control Plane)

Comments

UE

SS

0

Call the procedure P5 specified in TS 34.108 [9] clause7 to make the UE to transit to CELL_DCH

1

Cause UE high layer to provide APPLICATION LAYER MEASUREMENT REPORT with 1000 bytes "Container for application layer measurement reporting"

(Note1)

2

WAIT 20 seconds No MEASUREMENT REPORT

3

MEASUREMENT CONTROL(setup Application layer measurement)

RRC

Setup Application layer measurement

4

5

Cause UE high layer to provide APPLICATION LAYER MEASUREMENT REPORT with 1000 bytes "Container for application layer measurement reporting" (Note1)

6

SS waits 5 seconds from step3

7

Cause UE high layer to provide APPLICATION LAYER MEASUREMENT REPORT with 4000 bytes "Container for application layer measurement reporting" (Note1)

8

SS waits 5 seconds from step5

9

Cause UE high layer to provide APPLICATION LAYER MEASUREMENT REPORT with 8000 bytes "Container for application layer measurement reporting" (Note1)

10.1

APPLICATION LAYER MEASUREMENT REPORT with 1000 bytes "Container for application layer measurement reporting"

It could happen in parallel to steps 6-9

10.2

APPLICATION LAYER MEASUREMENT REPORT with 4000 bytes "Container for application layer measurement reporting"

It could happen in parallel to steps 6-9

10.3

APPLICATION LAYER MEASUREMENT REPORT with 8000 bytes "Container for application layer measurement reporting"

It could happen in parallel to steps 6-9

11

Timer expiration 30 seconds after step6

SS should have received 3 Application measurement reports each corresponding to previously transmitted Generate Application Layer Measurement Report command, and all the MEASUREMENT REPORTs must be transmitted on SRB4.

12

MEASUREMENT CONTROL (release Application layer measurement)

13

Cause UE high layer to provide APPLICATION LAYER MEASUREMENT REPORT with 1000 bytes "Container for application layer measurement reporting" (Note1)

14

Wait 20 seconds and verify that no further MEASUREMENT REPORT messages are detected on the uplink DCCH.

Note1: This indication may be triggered with the AT command +CAPPLEVMR specified in TS 27.007 clause 8.79 or any alternative way

Specific Message Contents

MEASUREMENT CONTROL (Step 3) (FDD)

Information Element

Value/remark

Measurement identity

16

Measurement command

Setup

– CHOICE measurement type

Application layer measurement configuration

-Container for application layer measurement configuration

Octet string (1…1000)

Additional measurement list

Not Present

MEASUREMENT REPORT (Step10) (FDD)

Information Element

Value/remark

Measurement identity

16

Measured Results

– CHOICE measurement

Application layer measurement report

Container for application layer measurement reporting

Octets string (1…8000)

MEASUREMENT CONTROL (Step12) (FDD)

Information Element

Value/remark

Measurement identity

16

Measurement command

Release

– CHOICE measurement type

Application layer measurement configuration

-Container for application layer measurement configuration

.

Additional measurement list

Not Present

8.4.1.53.5 Test Requirement

In step2 SS is not expected to receive any APPLICATION LAYER MEASUREMENT REPORT from UE;

In step10 SS is expected to receive all the MEASUREMENT REPORTs received on SRB4 and each of the container is identical to the one in the corresponding GENERATE APPLICATION LAYER MEASUREMENT REPORT;

In step14 SS is not expected to receive any APPLICATION LAYER MEASUREMENT REPORT from UE

8.4.1.54 Void

8.4.1.55 Void

8.4.1.56 Cell Update: Application layer measurement report available in URA_PCH

8.4.1.56.1 Definition

8.4.1.56.2 Conformance requirement

A UE shall initiate the cell update procedure in the following cases:

1> Uplink data transmission:

1> Transfer of application layer measurement report:

2> if the UE is in URA_PCH, CELL_PCH or CELL_FACH state; and

2> if the UE has received a "Container for application layer measurement reporting" which has not yet been sent:

3> perform cell update using the cause "application layer measurement report available".

NOTE: If the UE is not transferred to CELL_DCH after having successfully performed cell update using the cause "application layer measurement report available", the UE shall discard the application layer measurement report.

Reference 3GPP TS 25.331 clause 8.3.1

8.4.1.56.3 Test purpose

1. To confirm that the UE executes a cell update procedure when the UE has received a “Container for application layer measurement reporting” data which has not yet been sent if the UE is in URA_PCH state.

8.4.1.56.4 Method of test

Initial Condition

System Simulator: 1cell

UE: Registered Idle Mode on PS (state3)

Test Procedure

The UE is initially in Registered Idle Mode on PS (state3), and then the procedure P5 specified in TS 34.108 [9] clause7 is called to make the UE to transit to CELL_DCH. To execute procedure P5, all specific message contents are used as specified in TS 34.108[9] clause 9 with the exception in step 3. For step3, the message of the same type titled “RRC CONNECTION SETUP message: UM (Transition to CELL_DCH or in CELL_FACH)” including Signalling RB information to setup titled (AM DCCH for NAS_DT Low priority) under condition A2.

Then SS sends MEASUREMENT CONTROL message to UE to setup APPLICATION LAYER MEASUREMENT;

The SS transmits a PHYSICAL CHANNEL RECONFIGURATION message with IE "RRC State Indicator" set to "URA_PCH". The UE shall reply with PHYSICAL CHANNEL RECONFIGURATION COMPLETE message and move to URA_PCH state. Cause UE upper layer to send a "Container for application layer measurement reporting" to UE RRC layer, The UE then moves to CELL_FACH state and transmits a CELL UPDATE message to the SS on the uplink CCCH, with the IE "Cell update cause" set to value " Application layer measurement report available ". After receiving such a message, SS transmits CELL UPDATE CONFIRM message on downlink DCCH. Then the UE shall transmit “RADIO BEARER RECONFIGURATION COMPLETE” message to SS. The UE shall stay in CELL_DCH state and sent a MEASUREMENT REPORT message on the uplink DCCH to indicating “Application layer measurement reporting" using AM RLC on DCCH.

Expected sequence

Step

Direction

Message

Comment

UE

SS

0

Call the procedure P5 specified in TS 34.108 [9] clause7 to make the UE to transit to CELL_DCH

1

MEASUREMENT CONTROL(setup Application layer measurement)

RRC

Setup Application layer measurement

2

Wait 1 second for the measurement procedure to take effect.

3

PHYSICAL CHANNEL RECONFIGURATION

IE "RRC State Indicator" set to "URA_PCH"

4

PHYSICAL CHANNEL RECONFIGURATION COMPLETE

UE moves to URA_PCH state.

5

Cause UE high layer to provide APPLICATION LAYER MEASUREMENT REPORT with 1000 bytes "Container for application layer measurement reporting"

(Note1)

6

CELL UPDATE

The UE shall move to CELL FACH state and initiate cell update with the message set to “application layer measurement report available" in IE "Cell update cause".

7

CELL UPDATE CONFIRM

See message content.

8

RADIO BEAR RECONFIGURATION COMPLETE

See message content.

9

MEASUREMENT REPORT

Indicating “Application layer measurement reporting

10

RRC CONNECTION RELEASE

SS send RRC connection release to UE

11

RRC CONNECTION RELEASE COMPLETE

Note1: This indication may be triggered with the AT command +CAPPLEVMR specified in TS 27.007 clause 8.79 or any alternative way

Specific Message Contents

PHYSICAL CHANNEL RECONFIGURATION (Step 3)

Use the same message sub-type found in TS 34.108 clause 9, which is entitled "Packet to URA_PCH from CELL_DCH in PS ", with the following exceptions:

Information Element

Value/remark

New C-RNTI

Not Present

RRC State Indicator

URA_PCH

CELL UPDATE (Step 6)

The same message found in TS 34.108 clause 9 shall be transmitted by the UE on the uplink CCCH, with the exception of the following IEs:

Information Element

Value/remark

Cell Update Cause

Check to see if set to ‘Application layer measurement report available ‘

CELL UPDATE CONFIRM (Step 7)

Use the same message sub-type found in TS 34.108 clause 9, with the following exceptions:

Information Element

Value/remark

RRC State indicator

CELL_DCH

RB information to reconfigure list

Note1

DL Transport channel information common for all transport channels

Note1

Added or Reconfigured DL TrCH information

Note1

UL Transport channel information common for all transport channels

Note1

Added or Reconfigured UL TrCH information

Note1

Uplink DPCH info

Note1

Downlink information common for all radio links

Note1

Downlink information per radio link list

Note1

Note1: The according message contents of RADIO BEARER RECONFIGURATION message: AM or UM in TS 34.108 clause 9 entitled “Packet to CELL_DCH from CELL_FACH in PS”

RADIO BEARER RECONFIGURATION COMPLETE (Step 8)

Use the same message sub-type found in TS 34.108 clause 9.

MEASUREMENT REPORT (Step 9)

Check to see if the same message type found in TS 34.108 clause 9 is received, with the following exceptions:

Information Element

Value/remark

Measurement identity

16

Measured Results

– CHOICE measurement

Application layer measurement report

Container for application layer measurement reporting

Octets string (1…8000)

8.4.1.56.5 Test requirement

After step 6, the UE shall move to CELL_FACH state to initiate a cell update procedure and transmits a CELL UPDATE message which is set to “Container for application layer measurement reporting “in IE "Cell update cause".

After step 8, the UE shall transmit a RADIO BEARER RECONFIGURATION COMPLETE message on the uplink DCCH using AM RLC.

After step 9, UE shall transmit MEASUREMENT REPORT message to SS using AM RLC on DCCH SRB4.

8.4.1.57 Cell Update: Application layer measurement report available in CELL_PCH

8.4.1.57.1 Definition

8.4.1.57.2 Conformance requirement

A UE shall initiate the cell update procedure in the following cases:

1> Uplink data transmission:

1> Transfer of application layer measurement report:

2> if the UE is in URA_PCH, CELL_PCH or CELL_FACH state; and

2> if the UE has received a "Container for application layer measurement reporting" which has not yet been sent:

3> perform cell update using the cause "application layer measurement report available".

NOTE: If the UE is not transferred to CELL_DCH after having successfully performed cell update using the cause "application layer measurement report available", the UE shall discard the application layer measurement report.

Reference 3GPP TS 25.331 clause 8.3.1

8.4.1.57.3 Test purpose

1. To confirm that the UE executes a cell update procedure when the UE has received a “Container for application layer measurement reporting” data which has not yet been sent if the UE is in CELL_PCH state.

8.4.1.57.4 Method of test

Initial Condition

System Simulator: 1cell

UE: Registered Idle Mode on PS (state3).

Test Procedure

The UE is initially in Registered Idle Mode on PS (state3), and then the procedure P5 specified in TS 34.108 [9] clause7 is called to make the UE to transit to CELL_DCH. To execute procedure P5, all specific message contents are used as specified in TS 34.108[9] clause 9 with the exception in step 3. For step3, the message of the same type titled “RRC CONNECTION SETUP message: UM (Transition to CELL_DCH or in CELL_FACH)” including Signalling RB information to setup titled (AM DCCH for NAS_DT Low priority) under condition A2.

Then SS sends MEASUREMENT CONTROL message to UE to setup APPLICATION LAYER MEASUREMENT;

The SS transmits a PHYSICAL CHANNEL RECONFIGURATION message with IE "RRC State Indicator" set to "CELL_PCH". The UE shall reply with PHYSICAL CHANNEL RECONFIGURATION COMPLETE message and move to CELL_PCH state. Cause UE upper layer to send a "Container for application layer measurement reporting" to UE RRC layer, The UE then moves to CELL_FACH state and transmits a CELL UPDATE message to the SS on the uplink CCCH, with the IE "Cell update cause" set to value " Application layer measurement report available ". After receiving such a message, SS transmits CELL UPDATE CONFIRM message on downlink DCCH. Then the UE shall transmit “RADIO BEARER RECONFIGURATION COMPLETE” message to SS. The UE shall stay in CELL_DCH state and sent a MEASUREMENT REPORT message on the uplink DCCH to indicating “Application layer measurement reporting" using AM RLC on DCCH.

Expected sequence

Step

Direction

Message

Comment

UE

SS

0

Call the procedure P5 specified in TS 34.108 [9] clause7 to make the UE to transit to CELL_DCH

1

MEASUREMENT CONTROL(setup Application layer measurement)

RRC

Setup Application layer measurement

2

Wait 1 second for the measurement procedure to take effect.

3

PHYSICAL CHANNEL RECONFIGURATION

IE "RRC State Indicator" set to "CELL_PCH"

4

PHYSICAL CHANNEL RECONFIGURATION COMPLETE

UE moves to CELL_PCH state

5

Cause UE high layer to provide APPLICATION LAYER MEASUREMENT REPORT with 1000 bytes "Container for application layer measurement reporting" (Note1)

6

CELL UPDATE

The UE shall move to CELL FACH state and initiate cell update with the message set to “application layer measurement report available" in IE "Cell update cause"

7

CELL UPDATE CONFIRM

See message content

8

RADIO BEAR RECONFIGURATION COMPLETE

See message content

9

MEASUREMENT REPORT

Indicating “Application layer measurement reporting

10

RRC CONNECTION RELEASE

SS send RRC connection release to UE

11

RRC CONNECTION RELEASE COMPLETE

Note1: This indication may be triggered with the AT command +CAPPLEVMR specified in TS 27.007 clause 8.79or any alternative way

Specific Message Contents

PHYSICAL CHANNEL RECONFIGURATION (Step 3)

Use the same message sub-type found in TS 34.108 clause 9, which is entitled "Packet to CELL_PCH from CELL_DCH in PS", with the following exceptions:

Information Element

Value/remark

New C-RNTI

Not Present

RRC State Indicator

CELL_PCH

CELL UPDATE (Step 6)

The same message found in TS 34.108 clause 9 shall be transmitted by the UE on the uplink CCCH, with the exception of the following IEs:

Information Element

Value/remark

Cell Update Cause

Check to see if set to ‘Application layer measurement report available ‘

CELL UPDATE CONFIRM (Step 7)

Use the same message sub-type found in TS 34.108 clause 9, with the following exceptions:

Information Element

Value/remark

RRC State indicator

CELL_DCH

RB information to reconfigure list

Note1

DL Transport channel information common for all transport channels

Note1

Added or Reconfigured DL TrCH information

Note1

UL Transport channel information common for all transport channels

Note1

Added or Reconfigured UL TrCH information

Note1

Uplink DPCH info

Note1

Downlink information common for all radio links

Note1

Downlink information per radio link list

Note1

Note1: Reconfiguration of transport channels and physical channels refer to the contents of RADIO BEARER RECONFIGURATION message: AM or UM in TS 34.108 clause 9 entitled Packet to “CELL_DCH from CELL_FACH in PS”

RADIO BEARER RECONFIGURATION COMPLETE (Step 8)

Use the same message sub-type found in TS 34.108 clause 9.

MEASUREMENT REPORT (step 9)

Check to see if the same message type found in TS 34.108 clause 9 is received, with the following exceptions:

Information Element

Value/remark

Measurement identity

16

Measured Results

– CHOICE measurement

Application layer measurement report

Container for application layer measurement reporting

Octets string (1…8000).

8.4.1.57.5 Test requirement

After step 6, the UE shall move to CELL_FACH state to initiate a cell update procedure and transmits a CELL UPDATE message which is set to “Container for application layer measurement reporting “in IE "Cell update cause".

After step 8, the UE shall transmit a RADIO BEARER RECONFIGURATION COMPLETE message on the uplink DCCH using AM RLC.

After step 9, UE shall transmit MEASUREMENT REPORT message to SS using AM RLC on DCCH SRB4.

8.4.1.58 Cell Update: Application layer measurement report available in CELL_FACH

8.4.1.58.1 Definition

8.4.1.58.2 Conformance requirement

A UE shall initiate the cell update procedure in the following cases:

1> Uplink data transmission:

1> Transfer of application layer measurement report:

2> if the UE is in URA_PCH, CELL_PCH or CELL_FACH state; and

2> if the UE has received a "Container for application layer measurement reporting" which has not yet been sent:

3> perform cell update using the cause "application layer measurement report available".

NOTE: If the UE is not transferred to CELL_DCH after having successfully performed cell update using the cause "application layer measurement report available", the UE shall discard the application layer measurement report.

Reference 3GPP TS 25.331 clause 8.3.1

8.4.1.58.3 Test purpose

1. To confirm that the UE executes a cell update procedure when the UE has received a “Container for application layer measurement reporting” data which has not yet been sent if the UE is in CELL_FACH state.

8.4.1.58.4 Method of test

Initial Condition

System Simulator: 1cell

UE: Registered Idle Mode on PS (state3).

Test Procedure

The UE is initially in Registered Idle Mode on PS (state3), and then the procedure P5 specified in TS 34.108 [9] clause7 is called to make the UE to transit to CELL_DCH. To execute procedure P5, all specific message contents are used as specified in TS 34.108[9] clause 9 with the exception in step 3. For step3, the message of the same type titled “RRC CONNECTION SETUP message: UM (Transition to CELL_DCH or in CELL_FACH)” including Signalling RB information to setup titled (AM DCCH for NAS_DT Low priority) under condition A2.

Then SS sends MEASUREMENT CONTROL message to UE to setup APPLICATION LAYER MEASUREMENT;

UE is initially in CELL_FACH state. Cause UE upper layer to send a "Container for application layer measurement reporting" to UE RRC layer, The UE then transmits a CELL UPDATE message to the SS on the uplink CCCH, with the IE "Cell update cause" set to value " Application layer measurement report available ". After receiving such a message, SS transmits CELL UPDATE CONFIRM message on downlink DCCH. Then the UE shall transmit “RADIO BEARER RECONFIGURATION COMPLETE” message to SS. The UE shall stay in CELL_DCH state and sent a MEASUREMENT REPORT message on the uplink DCCH to indicating “Application layer measurement reporting" using AM RLC on DCCH.

Expected sequence

Step

Direction

Message

Comment

UE

SS

0

Call the procedure P5 specified in TS 34.108 [9] clause7 to make the UE to transit to CELL_DCH

1

MEASUREMENT CONTROL(setup Application layer measurement)

RRC

Setup Application layer measurement

2

Wait 1 second for the measurement procedure to take effect.

3

PHYSICAL CHANNEL RECONFIGURATION

IE "RRC State Indicator" set to "CELL_FACH"

1

Cause UE high layer to provide APPLICATION LAYER MEASUREMENT REPORT with 1000 bytes "Container for application layer measurement reporting".

Note1

5

CELL UPDATE

The UE shall move to CELL FACH state and initiate cell update with the message set to “application layer measurement report available" in IE "Cell update cause".

6

CELL UPDATE CONFIRM

See message content.

7

RADIO BEAR RECONFIGURATION COMPLETE

See message content.

8

MEASUREMENT REPORT

Indicating “Application layer measurement reporting

9

RRC CONNECTION RELEASE

SS send RRC connection release to UE

10

RRC CONNECTION RELEASE COMPLETE

Note1: This indication may be triggered with the AT command +CAPPLEVMR specified in TS 27.007 clause 8.79 or any alternative way

Specific Message Contents

CELL UPDATE (Step 5)

The same message found in TS 34.108 clause 9 shall be transmitted by the UE on the uplink CCCH, with the exception of the following IEs:

Information Element

Value/remark

Cell Update Cause

Check to see if set to ‘Application layer measurement report available ‘

CELL UPDATE CONFIRM (Step 6)

Use the same message sub-type found in TS 34.108 clause 9, with the following exceptions:

Information Element

Value/remark

RRC State indicator

CELL_DCH

RB information to reconfigure list

Note1

DL Transport channel information common for all transport channels

Note1

Added or Reconfigured DL TrCH information

Note1

UL Transport channel information common for all transport channels

Note1

Added or Reconfigured UL TrCH information

Note1

Uplink DPCH info

Note1

Downlink information common for all radio links

Note1

Downlink information per radio link list

Note1

Note1: Reconfiguration of transport channels and physical channels refer to the contents of RADIO BEARER RECONFIGURATION message: AM or UM in TS 34.108 clause 9 entitled “Packet to CELL_DCH from CELL_FACH in PS”

RADIO BEARER RECONFIGURATION COMPLETE (Step 7)

Use the same message sub-type found in TS 34.108 clause 9.

MEASUREMENT REPORT (Step 8)

Check to see if the same message type found in TS 34.108 clause 9 is received, with the following exceptions:

Information Element

Value/remark

Measurement identity

16

Measured Results

– CHOICE measurement

Application layer measurement report

Container for application layer measurement reporting

Octets string (1…8000).

8.4.1.58.5 Test requirement

After step 5, the UE shall move to CELL_FACH state to initiate a cell update procedure and transmits a CELL UPDATE message which is set to “Container for application layer measurement reporting “in IE "Cell update cause".

After step 7, the UE shall transmit a RADIO BEARER RECONFIGURATION COMPLETE message on the uplink DCCH using AM RLC.

After step 8, UE shall transmit MEASUREMENT REPORT message to SS using AM RLC on DCCH SRB4.