18.3.2 Combinations on DPCH

34.123-13GPPPart 1: Protocol conformance specificationRelease 15TSUser Equipment (UE) conformance specification

18.3.2.1 Stand-alone UL:1.7 DL:1.7 kbps SRBs for DCCH

Test to verify establishment and signalling of stand-alone signalling reference radio bearer configuration as specified in TS 34.108, clause 6.11.6.4.1.1.

The test case is performed by running test case 9.4.1 (Location updating / accepted) using the stand-alone signalling reference radio bearer configuration as specified in TS 34.108, clause 6.11.6.4.1.1.

18.3.2.1a Stand-alone UL:1.7 DL:1.7 kbps SRBs for DCCH (multiframe)

Test to verify establishment and signalling of stand-alone signalling reference radio bearer configuration as specified in TS 34.108, clause 6.11.6.4.1.1a.

The test case is performed by running test case 9.4.1 (Location updating / accepted) using the stand-alone signalling reference radio bearer configuration as specified in TS 34.108, clause 6.11.6.4.1.1a.

18.3.2.2 Stand-alone UL:3.4 DL:3.4 kbps SRBs for DCCH

Test to verify establishment and signalling of stand-alone signalling reference radio bearer configuration as specified in TS 34.108, clause 6.11.6.4.1.2.

The test case is performed by running test case 9.4.1 (Location updating / accepted) using the stand-alone signalling reference radio bearer configuration as specified in TS 34.108, clause 6.11.6.4.1.2.

18.3.2.3 Stand-alone UL:13.6 DL:13.6 kbps SRBs for DCCH

Implicitly tested.

NOTE The stand-alone UL:13.6 DL:13.6 kbps SRBs for DCCH in TS 34.108, clause 6.11.6.4.1.3 is the default signalling radio bearer used in the generic setup procedure as specified in TS 34.108 clause 7.

18.3.2.4 Conversational / speech / UL:12.2 DL:12.2 kbps / CS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH

18.3.2.4.1 Conformance requirement

The UE shall be able to establish the UTRAN requested radio bearers within the UE’s signalled radio access capabilities.

The UE shall correctly transfer user data from peer to peer RLC entities according to the requested radio bearer configuration.

Reference(s)

3GPP TS 25.331, clause 8.2.1

3GPP TS 25.2xx series (Physical Layer)

3GPP TS 25.321 (MAC)

3GPP TS 25.322 (RLC)

18.3.2.4.2 Test purpose

To verify radio bearer establishment and correct data transfer for reference radio bearer configuration as specified in TS 34.108, clause 6.11.6.4.1.4.

18.3.2.4.3 Method of test

Uplink TFS:

TFI

RB5

(RAB subflow #1)

RB6

(RAB subflow #2)

RB7

(RAB subflow #3)

DCCH

TFS

TF0, bits

0x81(alt. 1×0)

0x103

0x60

0x148

TF1, bits

1×39

1×103

1×60

1×148

TF2, bits

1×81

N/A

N/A

N/A

Uplink TFCS:

TFCI

(RB5, RB6, RB7, DCCH)

UL_TFC0

(TF0, TF0, TF0, TF0)

UL_TFC1

(TF1, TF0, TF0, TF0)

UL_TFC2

(TF2, TF1, TF1, TF0)

UL_TFC3

(TF0, TF0, TF0, TF1)

UL_TFC4

(TF1, TF0, TF0, TF1)

UL_TFC5

(TF2, TF1, TF1, TF1)

Downlink TFS:

RB5

(RAB subflow #1)

RB6

(RAB subflow #2)

RB7

(RAB subflow #3)

DCCH

TFS

TF0, bits

0x81(alt. 1×0)

0x103

0x60

0x148

TF1, bits

1×39

1×103

1×60

1×148

TF2, bits

1×81

N/A

N/A

N/A

Downlink TFCS:

TFCI

(RB5, RB6, RB7, DCCH)

DL_TFC0

(TF0, TF0, TF0, TF0)

DL_TFC1

(TF1, TF0, TF0, TF0)

DL_TFC2

(TF2, TF1, TF1, TF0)

DL_TFC3

(TF0, TF0, TF0, TF1)

DL_TFC4

(TF1, TF0, TF0, TF1)

DL_TFC5

(TF2, TF1, TF1, TF1)

Sub-tests:

Sub-test

Downlink TFCS

under test

Uplink TFCS

Under test

Implicitly tested

Restricted UL TFCIs

(note 1)

UL RLC SDU size

(note 2)

Test data size

(note 2)

1

DL_TFC1

UL_TFC1

DL_TFC0, DL_TFC3, UL_TFC0, UL_TFC3

UL_TFC0, UL_TFC1,

UL_TFC2,

UL_TFC3,

UL_TFC4

RB5: 39 bits

RB6: 103 bits

RB7: 60 bits

RB5: 39 bits

RB6: No data

RB7: No data

2

DL_TFC2

UL_TFC2

DL_TFC0, DL_TFC3, UL_TFC0, UL_TFC3

UL_TFC0, UL_TFC1,

UL_TFC2,

UL_TFC3, UL_TFC5

RB5: 81 bits

RB6: 103 bits

RB7: 60 bits

RB5: 81 bits

RB6: 103 bits

RB7: 60 bits

NOTE 1: UL_TFC0, UL_TFC1, UL_TFC2 and UL_TFC3 are part of minimum set of TFCIs.

NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs.

See 18.3.1.1 for test procedure.

18.3.2.4.4 Test requirements

See 18.3.1.1 for definition of step 10 and step 15.

1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.

2. At step 15 the UE transmitted transport format shall be

– for sub-test 1: RB5/TF1 (1×39).

– for sub-test 2: RB5/TF2 (1×81); RB6/TF1 (1×103); and RB7/TF1 (1×60).

3. At step 15 the UE shall return

– for sub-test 1: an RLC SDU on RB5 having the same content as sent by SS; and no data shall be received on RB6 or RB7.

– for sub-test 2: an RLC SDU on each of RB5, RB6 and RB7 having the same content as sent by SS

18.3.2.4a Conversational / speech / UL:(12.2 7.95 5.9 4.75) DL:(12.2 7.95 5.9 4.75) kbps / CS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH.

18.3.2.4a.1 Conformance requirement

See clause 18.3.2.4.1.

18.3.2.4a.2 Test purpose

Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.11.6.4.1.4a.

18.3.2.4a.3 Method of test

Uplink TFS:

TFI

RB5

(RAB subflow #1)

RB6

(RAB subflow #2)

RB7

(RAB subflow #3)

DCCH

TFS

TF0, bits

0x81(alt. 1×0)

0x103

0x60

0x148

TF1, bits

1×39

1×53

1×60

1×148

TF2, bits

1×42

1×63

N/A

N/A

TF3, bits

1×55

1×84

N/A

N/A

TF4, bits

1×75

1×103

N/A

N/A

TF5, bits

1×81

N/A

N/A

N/A

Uplink TFCS:

TFCI

(RB5, RB6, RB7,DCCH)

UL_TFC0

(TF0, TF0, TF0, TF0)

UL_TFC1

(TF1, TF0, TF0, TF0)

UL_TFC2

(TF2, TF1, TF0, TF0)

UL_TFC3

(TF3, TF2, TF0, TF0)

UL_TFC4

(TF4, TF3, TF0, TF0)

UL_TFC5

(TF5, TF4, TF1, TF0)

UL_TFC6

(TF0, TF0, TF0, TF1)

UL_TFC7

(TF1, TF0, TF0, TF1)

UL_TFC8

(TF2, TF1, TF0, TF1)

UL_TFC9

(TF3, TF2, TF0, TF1)

UL_TFC10

(TF4, TF3, TF0, TF1)

UL_TFC11

(TF5, TF4, TF1, TF1)

Downlink TFS:

RB5

(RAB subflow #1)

RB6

(RAB subflow #2)

RB7

(RAB subflow #3)

DCCH

TFS

TF0, bits

0x81(alt. 1×0)

0x103

0x60

0x148

TF1, bits

1×39

1×53

1×60

1×148

TF2, bits

1×42

1×63

N/A

N/A

TF3, bits

1×55

1×84

N/A

N/A

TF4, bits

1×75

1×103

N/A

N/A

TF5, bits

1×81

N/A

N/A

N/A

Downlink TFCS:

TFCI

(RB5, RB6, RB7, DCCH)

DL_TFC0

(TF0, TF0, TF0, TF0)

DL_TFC1

(TF1, TF0, TF0, TF0)

DL_TFC2

(TF2, TF1, TF0, TF0)

DL_TFC3

(TF3, TF2, TF0, TF0)

DL_TFC4

(TF4, TF3, TF0, TF0)

DL_TFC5

(TF5, TF4, TF1, TF0)

DL_TFC6

(TF0, TF0, TF0, TF1)

DL_TFC7

(TF1, TF0, TF0, TF1)

DL_TFC8

(TF2, TF1, TF0, TF1)

DL_TFC9

(TF3, TF2, TF0, TF1)

DL_TFC10

(TF4, TF3, TF0, TF1)

DL_TFC11

(TF5, TF4, TF1, TF1)

Sub-tests:

Sub-test

Downlink TFCS

under test

Uplink TFCS

Under test

Implicitly tested

Restricted UL TFCIs

(note 1)

UL RLC SDU size

(note 2)

Test data size

(note 2)

1

DL_TFC1

UL_TFC1

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6

UL_TFC0, UL_TFC1,

UL_TFC2,

UL_TFC3,

UL_TFC4,

UL_TFC5,

UL_TFC6,

UL_TFC7

RB5: 39 bits

RB6: 103 bits

RB7: 60 bits

RB5: 39 bits

RB6: No data

RB7: No data

2

DL_TFC2

UL_TFC2

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6

UL_TFC0, UL_TFC1,

UL_TFC2,

UL_TFC3,

UL_TFC4,

UL_TFC5,

UL_TFC6, UL_TFC8

RB5: 42 bits

RB6: 53 bits

RB7: 60 bits

RB5: 42 bits

RB6: 53 bits

RB7: No data

3

DL_TFC3

UL_TFC3

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC

UL_TFC0, UL_TFC1,

UL_TFC2,

UL_TFC3,

UL_TFC4,

UL_TFC5,

UL_TFC6, UL_TFC9

RB5: 55 bits

RB6: 63 bits

RB7: 60 bits

RB5: 55 bits

RB6: 63 bits

RB7: No data

4

DL_TFC4

UL_TFC4

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6

UL_TFC0, UL_TFC1,

UL_TFC2,

UL_TFC3,

UL_TFC4,

UL_TFC5,

UL_TFC6, UL_TFC10

RB5: 75 bits

RB6: 84 bits

RB7: 60 bits

RB5: 75 bits

RB6: 84 bits

RB7: No data

5

DL_TFC5

UL_TFC5

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6

UL_TFC0, UL_TFC1,

UL_TFC2,

UL_TFC3,

UL_TFC4,

UL_TFC5,

UL_TFC6, UL_TFC11

RB5: 81 bits

RB6: 103 bits

RB7: 60 bits

RB5: 81 bits

RB6: 103 bits

RB7: 60 bits

NOTE 1: UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3, UL_TFC4, UL_TFC5 and UL_TFC6 are part of minimum set of TFCIs.

NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs.

See clause 18.3.1.1 for test procedure.

18.3.2.4a.4 Test requirements

See 18.3.1.1 for definition of step 10 and step 15.

1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.

2. At step 15 the UE transmitted transport format shall be

– for sub-test 1: RB5/TF1 (1×39).

– for sub-test 2: RB5/TF2 (1×42) and RB6/TF1 (1×53)

– for sub-test 3: RB5/TF3 (1×55) and RB6/TF2 (1×63)

– for sub-test 4: RB5/TF4 (1×75) and RB6/TF3 (1×84)

– for sub-test 5: RB5/TF5 (1×81), RB6/TF4 (1×103) and RB7/TF1 (1×60)

3. At step 15 the UE shall return

– for sub-test 1: an RLC SDU on RB5 having the same content as sent by SS; and no data shall be received on RB6 or RB7.

– for sub-test 2,3 and 4: an RLC SDU on RB5 and RB6 having the same content as sent by SS; and no data shall be received on RB7.

– for sub-test 5: an RLC SDU on each of RB5, RB6 and RB7 having the same content as sent by SS.

18.3.2.5 Conversational / speech / UL:10.2 DL:10.2 kbps / CS RAB + UL:3.4 DL: 3.4 kbps SRBs for DCCH

18.3.2.5.1 Conformance requirement

See clause 18.3.2.4.1.

18.3.2.5.2 Test purpose

To verify radio bearer establishment and correct data transfer for reference radio bearer configuration as specified in TS 34.108, clause 6.11.6.4.1.5.

18.3.2.5.3 Method of test

Uplink TFS:

TFI

RB5

(RAB subflow #1)

RB6

(RAB subflow #2)

RB7

(RAB subflow #3)

DCCH

TFS

TF0, bits

0x65(alt. 1×0)

0x99

0x40

0x148

TF1, bits

1×39

1×99

1×40

1×148

TF2, bits

1×65

N/A

N/A

N/A

Uplink TFCS:

TFCI

(RB5, RB6, RB7,DCCH)

UL_TFC0

(TF0, TF0, TF0, TF0)

UL_TFC1

(TF1, TF0, TF0, TF0)

UL_TFC2

(TF2, TF1, TF1, TF0)

UL_TFC3

(TF0, TF0, TF0, TF1)

UL_TFC4

(TF1, TF0, TF0, TF1)

UL_TFC5

(TF2, TF1, TF1, TF1)

Downlink TFS:

RB5

(RAB subflow #1)

RB6

(RAB subflow #2)

RB7

(RAB subflow #3)

DCCH

TFS

TF0, bits

0x65(alt. 1×0)

0x99

0x40

0x148

TF1, bits

1×39

1×99

1×40

1×148

TF2, bits

1×65

N/A

N/A

N/A

Downlink TFCS:

TFCI

(RB5, RB6, RB7, DCCH)

DL_TFC0

(TF0, TF0, TF0, TF0)

DL_TFC1

(TF1, TF0, TF0, TF0)

DL_TFC2

(TF2, TF1, TF1, TF0)

DL_TFC3

(TF0, TF0, TF0, TF1)

DL_TFC4

(TF1, TF0, TF0, TF1)

DL_TFC5

(TF2, TF1, TF1, TF1)

Sub-tests:

Sub-test

Downlink TFCS

under test

Uplink TFCS

Under test

Implicitly tested

Restricted UL TFCIs

(note 1)

UL RLC SDU size

(note 2)

Test data size

(note 2)

1

DL_TFC1

UL_TFC1

DL_TFC0, DL_TFC3, UL_TFC0, UL_TFC3

UL_TFC0, UL_TFC1, UL_TFC2,

UL_TFC3,

UL_TFC4

RB5: 39 bits

RB6: 99 bits

RB7: 40 bits

RB5: 39 bits

RB6: No data

RB7: No data

2

DL_TFC2

UL_TFC2

DL_TFC0, DL_TFC3, UL_TFC0, UL_TFC3

UL_TFC0, UL_TFC1, UL_TFC2,

UL_TFC3, UL_TFC5

RB5: 65 bits

RB6: 99 bits

RB7: 40 bits

RB5: 65 bits

RB6: 99 bits

RB7: 40 bits

NOTE 1: UL_TFC0, UL_TFC1, UL_TFC2 and UL_TFC3 are part of minimum set of TFCIs.

NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs.

See clause 18.3.1.1 for test procedure.

18.3.2.5.4 Test requirements

See 18.3.1.1 for definition of step 10 and step 15.

1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.

2. At step 15 the UE transmitted transport format shall be

– for sub-test 1: RB5/TF1 (1×39).

– for sub-test 2: RB5/TF2 (1×65); RB6/TF1 (1×99); and RB7/TF1 (1×40).

3. At step 15 the UE shall return

– for sub-test 1: an RLC SDU on RB5 having the same content as sent by SS; and no data shall be received on RB6 or RB7.

– for sub-test 2: an RLC SDU on each of RB5, RB6 and RB7 having the same content as sent by SS.

18.3.2.5a Conversational / speech / UL:(10.2, 6.7, 5.9, 4.75) DL:(10.2, 6.7, 5.9, 4.75) kbps / CS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH.

18.3.2.5a.1 Conformance requirement

See clause 18.3.2.4.1.

18.3.2.5a.2 Test purpose

To verify radio bearer establishment and correct data transfer for reference radio bearer configuration as specified in TS 34.108, clause 6.11.6.4.1.5a.

18.3.2.5a.3 Method of test

Uplink TFS:

TFI

RB5

(RAB subflow #1)

RB6

(RAB subflow #2)

RB7

(RAB subflow #3)

DCCH

TFS

TF0, bits

0x65(alt. 1×0)

0x99

0x40

0x148

TF1, bits

1×39

1×53

1×40

1×148

TF2, bits

1×42

1×63

N/A

N/A

TF3, bits

1×55

1×76

N/A

N/A

TF4, bits

1×58

1×99

N/A

N/A

TF5, bits

1×65

N/A

N/A

N/A

Uplink TFCS:

TFCI

(RB5, RB6, RB7,DCCH)

UL_TFC0

(TF0, TF0, TF0, TF0)

UL_TFC1

(TF1, TF0, TF0, TF0)

UL_TFC2

(TF2, TF1, TF0, TF0)

UL_TFC3

(TF3, TF2, TF0, TF0)

UL_TFC4

(TF4, TF3, TF0, TF0)

UL_TFC5

(TF5, TF4, TF1, TF0)

UL_TFC6

(TF0, TF0, TF0, TF1)

UL_TFC7

(TF1, TF0, TF0, TF1)

UL_TFC8

(TF2, TF1, TF0, TF1)

UL_TFC9

(TF3, TF2, TF0, TF1)

UL_TFC10

(TF4, TF3, TF0, TF1)

UL_TFC11

(TF5, TF4, TF1, TF1)

Downlink TFS:

RB5

(RAB subflow #1)

RB6

(RAB subflow #2)

RB7

(RAB subflow #3)

DCCH

TFS

TF0, bits

0x65(alt. 1×0)

0x99

0x40

0x148

TF1, bits

1×39

1×53

1×40

1×148

TF2, bits

1×42

1×63

N/A

N/A

TF3, bits

1×55

1×76

N/A

N/A

TF4, bits

1×58

1×99

N/A

N/A

TF5, bits

1×65

N/A

N/A

N/A

Downlink TFCS:

TFCI

(RB5, RB6, RB7, DCCH)

DL_TFC0

(TF0, TF0, TF0, TF0)

DL_TFC1

(TF1, TF0, TF0, TF0)

DL_TFC2

(TF2, TF1, TF0, TF0)

DL_TFC3

(TF3, TF2, TF0, TF0)

DL_TFC4

(TF4, TF3, TF0, TF0)

DL_TFC5

(TF5, TF4, TF1, TF0)

DL_TFC6

(TF0, TF0, TF0, TF1)

DL_TFC7

(TF1, TF0, TF0, TF1)

DL_TFC8

(TF2, TF1, TF0, TF1)

DL_TFC9

(TF3, TF2, TF0, TF1)

DL_TFC10

(TF4, TF3, TF0, TF1)

DL_TFC11

(TF5, TF4, TF1, TF1)

Sub-tests:

Sub-test

Downlink TFCS

under test

Uplink TFCS

Under test

Implicitly tested

Restricted UL TFCIs

(note 1)

UL RLC SDU size

(note 2)

Test data size

(note 2)

1

DL_TFC1

UL_TFC1

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6

UL_TFC0, UL_TFC1,

UL_TFC2,

UL_TFC3,

UL_TFC4,

UL_TFC5,

UL_TFC6,

UL_TFC7

RB5: 39 bits

RB6: 99 bits

RB7: 40 bits

RB5: 39 bits

RB6: No data

RB7: No data

2

DL_TFC2

UL_TFC2

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6

UL_TFC0, UL_TFC1,

UL_TFC2,

UL_TFC3,

UL_TFC4,

UL_TFC5,

UL_TFC6, UL_TFC8

RB5: 42 bits

RB6: 53 bits

RB7: 40 bits

RB5: 42 bits

RB6: 53 bits

RB7: No data

3

DL_TFC3

UL_TFC3

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC

UL_TFC0, UL_TFC1,

UL_TFC2,

UL_TFC3,

UL_TFC4,

UL_TFC5,

UL_TFC6, UL_TFC9

RB5: 55 bits

RB6: 63 bits

RB7: 40 bits

RB5: 55 bits

RB6: 63 bits

RB7: No data

4

DL_TFC4

UL_TFC4

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6

UL_TFC0, UL_TFC1,

UL_TFC2,

UL_TFC3,

UL_TFC4,

UL_TFC5,

UL_TFC6, UL_TFC10

RB5: 58 bits

RB6: 76 bits

RB7: 40 bits

RB5: 58 bits

RB6: 76 bits

RB7: No data

5

DL_TFC5

UL_TFC5

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6

UL_TFC0, UL_TFC1,

UL_TFC2,

UL_TFC3,

UL_TFC4,

UL_TFC5,

UL_TFC6, UL_TFC11

RB5: 65 bits

RB6: 99 bits

RB7: 40 bits

RB5: 65 bits

RB6: 99 bits

RB7: 40 bits

NOTE 1: UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3, UL_TFC4, UL_TFC5 and UL_TFC6 are part of minimum set of TFCIs.

NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs.

See clause 18.3.1.1 for test procedure.

18.3.2.5a.4 Test requirements

See 18.3.1.1 for definition of step 10 and step 15.

1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.

2. At step 15 the UE transmitted transport format shall be

– for sub-test 1: RB5/TF1 (1×39).

– for sub-test 2: RB5/TF2 (1×42) and RB6/TF1 (1×53)

– for sub-test 3: RB5/TF3 (1×55) and RB6/TF2 (1×63)

– for sub-test 4: RB5/TF4 (1×58) and RB6/TF3 (1×76)

– for sub-test 5: RB5/TF5 (1×65), RB6/TF4 (1×99) and RB7/TF1 (1×40)

3. At step 15 the UE shall return

– for sub-test 1: an RLC SDU on RB5 having the same content as sent by the SS; and no data shall be received on RB6 or RB7.

– for sub-test 2, 3 and 4: an RLC SDU on RB5 and RB6 having the same content as sent by the SS; and no data shall be received on RB7.

– for sub-test 5: an RLC SDU on each of RB5, RB6 and RB7 having the same content as sent by the SS.

18.3.2.6 Conversational / speech / UL:7.95 DL:7.95 kbps / CS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH

18.3.2.6.1 Conformance requirement

See clause 18.3.2.4.1.

18.3.2.6.2 Test purpose

To verify radio bearer establishment and correct data transfer for reference radio bearer configuration as specified in TS 34.108, clause 6.11.6.4.1.6.

18.3.2.6.3 Method of test

Uplink TFS:

TFI

RB5

(RAB subflow #1)

RB6

(RAB subflow #2)

DCCH

TFS

TF0, bits

0x75(alt. 1×0)

0x84

0x148

TF1, bits

1×39

1×84

1×148

TF2, bits

1×75

N/A

N/A

Uplink TFCS:

TFCI

(RB5, RB6, DCCH)

UL_TFC0

(TF0, TF0, TF0)

UL_TFC1

(TF1, TF0, TF0)

UL_TFC2

(TF2, TF1, TF0)

UL_TFC3

(TF0, TF0, TF1)

UL_TFC4

(TF1, TF0, TF1)

UL_TFC5

(TF2, TF1, TF1)

Downlink TFS:

RB5

(RAB subflow #1)

RB6

(RAB subflow #2)

DCCH

TFS

TF0, bits

0x75(alt. 1×0)

0x84

0x148

TF1, bits

1×39

1×84

1×148

TF2, bits

1×75

N/A

N/A

Downlink TFCS:

TFCI

(RB5, RB6, DCCH)

DL_TFC0

(TF0, TF0, TF0)

DL_TFC1

(TF1, TF0, TF0)

DL_TFC2

(TF2, TF1, TF0)

DL_TFC3

(TF0, TF0, TF1)

DL_TFC4

(TF1, TF0, TF1)

DL_TFC5

(TF2, TF1, TF1)

Sub-tests:

Sub-test

Downlink TFCS

under test

Uplink TFCS

Under test

Implicitly tested

Restricted UL TFCIs

(note 1)

UL RLC SDU size

(note 2)

Test data size

(note 2)

1

DL_TFC1

UL_TFC1

DL_TFC0, DL_TFC3, UL_TFC0, UL_TFC3

UL_TFC0, UL_TFC1,

UL_TFC2, UL_TFC3,

UL_TFC4

RB5: 39 bits

RB6: 84 bits

RB5: 39 bits

RB6: No data

2

DL_TFC2

UL_TFC2

DL_TFC0, DL_TFC3, UL_TFC0, UL_TFC3

UL_TFC0, UL_TFC1, UL_TFC2,

UL_TFC3, UL_TFC5,

RB5: 75 bits

RB6: 84 bits

RB5: 75 bits

RB6: 84 bits

NOTE 1: UL_TFC0, UL_TFC1, UL_TFC2 and UL_TFC3 are part of minimum set of TFCIs.

NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs.

See clause 18.3.1.1 for test procedure.

.

18.3.2.6.4 Test requirements

See 18.3.1.1 for definition of step 10 and step 15.

1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.

2. At step 15 the UE transmitted transport format shall be

– for sub-test 1: RB5/TF1 (1×39).

– for sub-test 2: RB5/TF2 (1×75) and RB6/TF1 (1×84).

3. At step 15 the UE shall return

– for sub-test 1: an RLC SDU on RB5 having the same content as sent by SS; and no data shall be received on RB6.

– for sub-test 2: an RLC SDU on each of RB5 and RB6 having the same content as sent by SS.

18.3.2.7 Conversational / speech / UL:7.4 DL:7.4 kbps / CS RAB+ UL:3.4 DL:3.4 kbps SRBs for DCCH

18.3.2.7.1 Conformance requirement

See clause 18.3.2.4.1.

18.3.2.7.2 Test purpose

To verify radio bearer establishment and correct data transfer for reference radio bearer configuration as specified in TS 34.108, clause 6.11.6.4.1.7.

18.3.2.7.3 Method of test

Uplink TFS:

TFI

RB5

(RAB subflow #1)

RB6

(RAB subflow #2)

DCCH

TFS

TF0, bits

0x61 (alt. 1×0)

0x87

0x148

TF1, bits

1×39

1×87

1×148

TF2, bits

1×61

N/A

N/A

Uplink TFCS:

TFCI

(RB5, RB6, DCCH)

UL_TFC0

(TF0, TF0, TF0)

UL_TFC1

(TF1, TF0, TF0)

UL_TFC2

(TF2, TF1, TF0)

UL_TFC3

(TF0, TF0, TF1)

UL_TFC4

(TF1, TF0, TF1)

UL_TFC5

(TF2, TF1, TF1)

Downlink TFS:

RB5

(RAB subflow #1)

RB6

(RAB subflow #2)

DCCH

TFS

TF0, bits

0x61 (alt. 1×0)

0x87

0x148

TF1, bits

1×39

1×87

1×148

TF2, bits

1×61

N/A

N/A

Downlink TFCS:

TFCI

(RB5, RB6, DCCH)

DL_TFC0

(TF0, TF0, TF0)

DL_TFC1

(TF1, TF0, TF0)

DL_TFC2

(TF2, TF1, TF0)

DL_TFC3

(TF0, TF0, TF1)

DL_TFC4

(TF1, TF0, TF1)

DL_TFC5

(TF2, TF1, TF1)

Sub-tests:

Sub-test

Downlink TFCS

under test

Uplink TFCS

Under test

Implicitly tested

Restricted UL TFCIs

(note 1)

UL RLC SDU size

(note 2)

Test data size

(note 2)

1

DL_TFC1

UL_TFC1

DL_TFC0, DL_TFC3, UL_TFC0, UL_TFC3

UL_TFC0, UL_TFC1,

UL_TFC2, UL_TFC3,

UL_TFC4

RB5: 39 bits

RB6: 87 bits

RB5: 39 bits

RB6: No data

2

DL_TFC2

UL_TFC2

DL_TFC0, DL_TFC3, UL_TFC0, UL_TFC3

UL_TFC0, UL_TFC1, UL_TFC2,

UL_TFC3, UL_TFC5,

RB5: 61 bits

RB6: 87 bits

RB5: 61 bits

RB6: 87 bits

NOTE 1: UL_TFC0, UL_TFC1, UL_TFC2 and UL_TFC3 are part of minimum set of TFCIs.

NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs.

See clause 18.3.1.1 for test procedure.

18.3.2.7.4 Test requirements

See 18.3.1.1 for definition of step 10 and step 15.

1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.

2. At step 15 the UE transmitted transport format shall be

– for sub-test 1: RB5/TF1 (1×39).

– for sub-test 2: RB5/TF2 (1×61) and RB6/TF1 (1×87).

3. At step 15 the UE shall return

– for sub-test 1: an RLC SDU on RB5 having the same content as sent by SS; and no data shall be received on RB6.

– for sub-test 2: an RLC SDU on each of RB5 and RB6 having the same content as sent by SS

18.3.2.7a Conversational / speech / UL:(7.4, 6.7, 5.9, 4.75) DL:(7.4, 6.7, 5.9, 4.75) kbps / CS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH.

18.3.2.7a.1 Conformance requirement

See clause 18.3.2.4.1.

18.3.2.7a.2 Test purpose

To verify radio bearer establishment and correct data transfer for reference radio bearer configuration as specified in TS 34.108, clause 6.11.6.4.1.7a.

18.3.2.7a.3 Method of test

Uplink TFS:

TFI

RB5

(RAB subflow #1)

RB6

(RAB subflow #2)

DCCH

TFS

TF0, bits

0x61(alt. 1×0)

0x87

0x148

TF1, bits

1×39

1×53

1×148

TF2, bits

1×42

1×63

N/A

TF3, bits

1×55

1×76

N/A

TF4, bits

1×58

1×87

N/A

TF5, bits

1×61

N/A

N/A

Uplink TFCS:

TFCI

(RB5, RB6, RB7,DCCH)

UL_TFC0

(TF0, TF0, TF0)

UL_TFC1

(TF1, TF0, TF0)

UL_TFC2

(TF2, TF1, TF0)

UL_TFC3

(TF3, TF2, TF0)

UL_TFC4

(TF4, TF3, TF0)

UL_TFC5

(TF5, TF4, TF0)

UL_TFC6

(TF0, TF0, TF1)

UL_TFC7

(TF1, TF0, TF1)

UL_TFC8

(TF2, TF1, TF1)

UL_TFC9

(TF3, TF2, TF1)

UL_TFC10

(TF4, TF3, TF1)

UL_TFC11

(TF5, TF4, TF1)

Downlink TFS:

RB5

(RAB subflow #1)

RB6

(RAB subflow #2)

DCCH

TFS

TF0, bits

0x61 (alt. 1×0)

0x87

0x148

TF1, bits

1×39

1×53

1×148

TF2, bits

1×42

1×63

N/A

TF3, bits

1×55

1×76

N/A

TF4, bits

1×58

1×87

N/A

TF5, bits

1×61

N/A

N/A

Downlink TFCS:

TFCI

(RB5, RB6, RB7, DCCH)

DL_TFC0

(TF0, TF0, TF0)

DL_TFC1

(TF1, TF0, TF0)

DL_TFC2

(TF2, TF1, TF0)

DL_TFC3

(TF3, TF2, TF0)

DL_TFC4

(TF4, TF3, TF0)

DL_TFC5

(TF5, TF4, TF0)

DL_TFC6

(TF0, TF0, TF1)

DL_TFC7

(TF1, TF0, TF1)

DL_TFC8

(TF2, TF1, TF1)

DL_TFC9

(TF3, TF2, TF1)

DL_TFC10

(TF4, TF3, TF1)

DL_TFC11

(TF5, TF4, TF1)

Sub-tests:

Sub-test

Downlink TFCS

under test

Uplink TFCS

Under test

Implicitly tested

Restricted UL TFCIs

(note 1)

UL RLC SDU size

(note 2)

Test data size

(note 2)

1

DL_TFC1

UL_TFC1

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6

UL_TFC0, UL_TFC1,

UL_TFC2,

UL_TFC3,

UL_TFC4,

UL_TFC5,

UL_TFC6,

UL_TFC7

RB5: 39 bits

RB6: 87 bits

RB5: 39 bits

RB6: No data

2

DL_TFC2

UL_TFC2

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6

UL_TFC0, UL_TFC1,

UL_TFC2,

UL_TFC3,

UL_TFC4,

UL_TFC5,

UL_TFC6, UL_TFC8

RB5: 42 bits

RB6: 53 bits

RB5: 42 bits

RB6: 53 bits

3

DL_TFC3

UL_TFC3

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6

UL_TFC0, UL_TFC1,

UL_TFC2,

UL_TFC3,

UL_TFC4,

UL_TFC5,

UL_TFC6, UL_TFC9

RB5: 55 bits

RB6: 63 bits

RB5: 55 bits

RB6: 63 bits

4

DL_TFC4

UL_TFC4

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6

UL_TFC0, UL_TFC1,

UL_TFC2,

UL_TFC3,

UL_TFC4,

UL_TFC5,

UL_TFC6, UL_TFC10

RB5: 58 bits

RB6: 76 bits

RB5: 58 bits

RB6: 76 bits

5

DL_TFC5

UL_TFC5

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6

UL_TFC0, UL_TFC1,

UL_TFC2,

UL_TFC3,

UL_TFC4,

UL_TFC5,

UL_TFC6, UL_TFC11

RB5: 61 bits

RB6: 87 bits

RB5: 61 bits

RB6: 87 bits

NOTE 1: UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3, UL_TFC4, UL_TFC5 and UL_TFC6 are part of minimum set of TFCIs.

NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs.

See clause 18.3.1.1 for test procedure.

18.3.2.7a.4 Test requirements

See 18.3.1.1 for definition of step 10 and step 15.

1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.

2. At step 15 the UE transmitted transport format shall be

– for sub-test 1: RB5/TF1 (1×39).

– for sub-test 2: RB5/TF2 (1×42) and RB6/TF1 (1×53)

– for sub-test 3: RB5/TF3 (1×55) and RB6/TF2 (1×63)

– for sub-test 4: RB5/TF4 (1×58) and RB6/TF3 (1×76)

– for sub-test 5: RB5/TF5 (1×61) and RB6/TF4 (1×87)

3. At step 15 the UE shall return

– for sub-test 1: an RLC SDU on RB5 having the same content as sent by the SS; and no data shall be received on RB6.

– for sub-test 2 to 5: an RLC SDU on RB5 and RB6 having the same content as sent by the SS.

18.3.2.8 Conversational / speech / UL:6.7 DL:6.7 kbps / CS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH

18.3.2.8.1 Conformance requirement

See clause 18.3.2.4.1.

18.3.2.8.2 Test purpose

To verify radio bearer establishment and correct data transfer for reference radio bearer configuration as specified in TS 34.108, clause 6.11.6.4.1.8.

18.3.2.8.3 Method of test

Uplink TFS:

TFI

RB5

(RAB subflow #1)

RB6

(RAB subflow #2)

DCCH

TFS

TF0, bits

0x58(alt. 1×0)

0x76

0x148

TF1, bits

1×39

1×76

1×148

TF2, bits

1×58

N/A

N/A

Uplink TFCS:

TFCI

(RB5, RB6, DCCH)

UL_TFC0

(TF0, TF0, TF0)

UL_TFC1

(TF1, TF0, TF0)

UL_TFC2

(TF2, TF1, TF0)

UL_TFC3

(TF0, TF0, TF1)

UL_TFC4

(TF1, TF0, TF1)

UL_TFC5

(TF2, TF1, TF1)

Downlink TFS:

RB5

(RAB subflow #1)

RB6

(RAB subflow #2)

DCCH

TFS

TF0, bits

0x58(alt. 1×0)

0x76

0x148

TF1, bits

1×39

1×76

1×148

TF2, bits

1×58

N/A

N/A

Downlink TFCS:

TFCI

(RB5, RB6, DCCH)

DL_TFC0

(TF0, TF0, TF0)

DL_TFC1

(TF1, TF0, TF0)

DL_TFC2

(TF2, TF1, TF0)

DL_TFC3

(TF0, TF0, TF1)

DL_TFC4

(TF1, TF0, TF1)

DL_TFC5

(TF2, TF1, TF1)

Sub-tests:

Sub-test

Downlink TFCS

under test

Uplink TFCS

Under test

Implicitly tested

Restricted UL TFCIs

(note 1)

UL RLC SDU size

(note 2)

Test data size

(note 2)

1

DL_TFC1

UL_TFC1

DL_TFC0, DL_TFC3, UL_TFC0, UL_TFC3

UL_TFC0, UL_TFC1,

UL_TFC2, UL_TFC3,

UL_TFC4

RB5: 39 bits

RB6: 76 bits

RB5: 39 bits

RB6: No data

2

DL_TFC2

UL_TFC2

DL_TFC0, DL_TFC3, UL_TFC0, UL_TFC3

UL_TFC0, UL_TFC1, UL_TFC2,

UL_TFC3, UL_TFC5,

RB5: 58 bits

RB6: 76 bits

RB5: 58 bits

RB6: 76 bits

NOTE 1: UL_TFC0, UL_TFC1, UL_TFC2 and UL_TFC3 are part of minimum set of TFCIs.

NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs.

See clause 18.3.1.1 for test procedure.

18.3.2.8.4 Test requirements

See clause 18.3.1.1 for definition of step 10 and step 15.

1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.

2. At step 15 the UE transmitted transport format shall be

– for sub-test 1: RB5/TF1 (1×39).

– for sub-test 2: RB5/TF2 (1×58) and RB6/TF1 (1×76).

3. At step 15 the UE shall return

– for sub-test 1: an RLC SDU on RB5 having the same content as sent by SS; and no data shall be received on RB6.

– for sub-test 2: an RLC SDU on each of RB5 and RB6 having the same content as sent by SS

18.3.2.9 Conversational / speech / UL:5.9 DL:5.9 kbps / CS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH

18.3.2.9.1 Conformance requirement

See clause 18.3.2.4.1.

18.3.2.9.2 Test purpose

To verify radio bearer establishment and correct data transfer for reference radio bearer configuration as specified in TS 34.108, clause 6.11.6.4.1.9.

18.3.2.9.3 Method of test

Uplink TFS:

TFI

RB5

(RAB subflow #1)

RB6

(RAB subflow #2)

DCCH

TFS

TF0, bits

0x55(alt. 1×0)

0x63

0x148

TF1, bits

1×39

1×63

1×148

TF2, bits

1×55

N/A

N/A

Uplink TFCS:

TFCI

(RB5, RB6, DCCH)

UL_TFC0

(TF0, TF0, TF0)

UL_TFC1

(TF1, TF0, TF0)

UL_TFC2

(TF2, TF1, TF0)

UL_TFC3

(TF0, TF0, TF1)

UL_TFC4

(TF1, TF0, TF1)

UL_TFC5

(TF2, TF1, TF1)

Downlink TFS:

RB5

(RAB subflow #1)

RB6

(RAB subflow #2)

DCCH

TFS

TF0, bits

0x55 (alt. 1×0)

0x63

0x148

TF1, bits

1×39

1×63

1×148

TF2, bits

1×55

N/A

N/A

Downlink TFCS:

TFCI

(RB5, RB6, DCCH)

DL_TFC0

(TF0, TF0, TF0)

DL_TFC1

(TF1, TF0, TF0)

DL_TFC2

(TF2, TF1, TF0)

DL_TFC3

(TF0, TF0, TF1)

DL_TFC4

(TF1, TF0, TF1)

DL_TFC5

(TF2, TF1, TF1)

Sub-tests:

Sub-test

Downlink TFCS

under test

Uplink TFCS

Under test

Implicitly tested

Restricted UL TFCIs

(note 1)

UL RLC SDU size

(note 2)

Test data size

(note 2)

1

DL_TFC1

UL_TFC1

DL_TFC0, DL_TFC3, UL_TFC0, UL_TFC3

UL_TFC0, UL_TFC1,

UL_TFC2, UL_TFC3,

UL_TFC4

RB5: 39 bits

RB6: 63 bits

RB5: 39 bits

RB6: No data

2

DL_TFC2

UL_TFC2

DL_TFC0, DL_TFC3, UL_TFC0, UL_TFC3

UL_TFC0, UL_TFC1, UL_TFC2,

UL_TFC3, UL_TFC5,

RB5: 55 bits

RB6: 63 bits

RB5: 55 bits

RB6: 63 bits

NOTE 1: UL_TFC0, UL_TFC1, UL_TFC2 and UL_TFC3 are part of minimum set of TFCIs.

NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs.

See clause 18.3.1.1 for test procedure.

18.3.2.9.4 Test requirements

See 18.3.1.1 for definition of step 10 and step 15.

1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.

2. At step 15 the UE transmitted transport format shall be

– for sub-test 1: RB5/TF1 (1×39).

– for sub-test 2: RB5/TF2 (1×55) and RB6/TF1 (1×63).

3. At step 15 the UE shall return

– for sub-test 1: an RLC SDU on RB5 having the same content as sent by SS; and no data shall be received on RB6.

– for sub-test 2: an RLC SDU on each of RB5 and RB6 having the same content as sent by SS

18.3.2.10 Conversational / speech / UL:5.15 DL:5.15 kbps / CS RAB + UL:1.7 DL:1.7 kbps SRBs for DCCH

18.3.2.10.1 Conformance requirement

See clause 18.3.2.4.1.

18.3.2.10.2 Test purpose

To verify radio bearer establishment and correct data transfer for reference radio bearer configuration as specified in TS 34.108, clause 6.11.6.4.1.10.

18.3.2.10.3 Method of test

Uplink TFS:

TFI

RB5

(RAB subflow #1)

RB6

(RAB subflow #2)

DCCH

TFS

TF0, bits

0x49 (alt. 1×0)

0x54

0x148

TF1, bits

1×39

1×54

1×148

TF2, bits

1×49

N/A

N/A

Uplink TFCS:

TFCI

(RB5, RB6, DCCH)

UL_TFC0

(TF0, TF0, TF0)

UL_TFC1

(TF1, TF0, TF0)

UL_TFC2

(TF2, TF1, TF0)

UL_TFC3

(TF0, TF0, TF1)

UL_TFC4

(TF1, TF0, TF1)

UL_TFC5

(TF2, TF1, TF1)

Downlink TFS:

RB5

(RAB subflow #1)

RB6

(RAB subflow #2)

DCCH

TFS

TF0, bits

0x49 (alt. 1×0)

0x54

0x148

TF1, bits

1×39

1×54

1×148

TF2, bits

1×49

N/A

N/A

Downlink TFCS:

TFCI

(RB5, RB6, DCCH)

DL_TFC0

(TF0, TF0, TF0)

DL_TFC1

(TF1, TF0, TF0)

DL_TFC2

(TF2, TF1, TF0)

DL_TFC3

(TF0, TF0, TF1)

DL_TFC4

(TF1, TF0, TF1)

DL_TFC5

(TF2, TF1, TF1)

Sub-tests:

Sub-test

Downlink TFCS

under test

Uplink TFCS

Under test

Implicitly tested

Restricted UL TFCIs

(note 1)

UL RLC SDU size

(note 2)

Test data size

(note 2)

1

DL_TFC1

UL_TFC1

DL_TFC0, DL_TFC3, UL_TFC0, UL_TFC3

UL_TFC0, UL_TFC1,

UL_TFC2, UL_TFC3,

UL_TFC4

RB5: 39 bits

RB6: 54 bits

RB5: 39 bits

RB6: No data

2

DL_TFC2

UL_TFC2

DL_TFC0, DL_TFC3, UL_TFC0, UL_TFC3

UL_TFC0, UL_TFC1, UL_TFC2,

UL_TFC3, UL_TFC5,

RB5: 49 bits

RB6: 54 bits

RB5: 49 bits

RB6: 54 bits

NOTE 1: UL_TFC0, UL_TFC1, UL_TFC2 and UL_TFC3 are part of minimum set of TFCIs.

NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs.

See clause 18.3.1.1 for test procedure.

18.3.2.10.4 Test requirements

See 18.3.1.1 for definition of step 10 and step 15.

1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.

2. At step 15 the UE transmitted transport format shall be

– for sub-test 1: RB5/TF1 (1×39).

– for sub-test 2: RB5/TF2 (1×49) and RB6/TF1 (1×54).

3. At step 15 the UE shall return

– for sub-test 1: an RLC SDU on RB5 having the same content as sent by SS; and no data shall be received on RB6.

– for sub-test 2: an RLC SDU on each of RB5 and RB6 having the same content as sent by SS

18.3.2.11 Conversational / speech / UL:4.75 DL:4.75 kbps / CS RAB + UL:1.7 DL:1.7 kbps SRBs for DCCH

18.3.2.11.1 Conformance requirement

See clause 18.3.2.4.1.

18.3.2.11.2 Test purpose

To verify radio bearer establishment and correct data transfer for reference radio bearer configuration as specified in TS 34.108, clause 6.11.6.4.1.11.

18.3.2.11.3 Method of test

Uplink TFS:

TFI

RB5

(RAB subflow #1)

RB6

(RAB subflow #2)

DCCH

TFS

TF0, bits

0x49(alt.1×0 )

0x53

0x148

TF1, bits

1×39

1×53

1×148

TF2, bits

1×42

N/A

N/A

Uplink TFCS:

TFCI

(RB5, RB6, DCCH)

UL_TFC0

(TF0, TF0, TF0)

UL_TFC1

(TF1, TF0, TF0)

UL_TFC2

(TF2, TF1, TF0)

UL_TFC3

(TF0, TF0, TF1)

UL_TFC4

(TF1, TF0, TF1)

UL_TFC5

(TF2, TF1, TF1)

Downlink TFS:

RB5

(RAB subflow #1)

RB6

(RAB subflow #2)

DCCH

TFS

TF0, bits

0X42 (alt.1×0 )

0x53

0x148

TF1, bits

1×39

1×53

1×148

TF2, bits

1×42

N/A

N/A

Downlink TFCS:

TFCI

(RB5, RB6, DCCH)

DL_TFC0

(TF0, TF0, TF0)

DL_TFC1

(TF1, TF0, TF0)

DL_TFC2

(TF2, TF1, TF0)

DL_TFC3

(TF0, TF0, TF1)

DL_TFC4

(TF1, TF0, TF1)

DL_TFC5

(TF2, TF1, TF1)

Sub-tests:

Sub-test

Downlink TFCS

under test

Uplink TFCS

Under test

Implicitly tested

Restricted UL TFCIs

(note 1)

UL RLC SDU size

(note 2)

Test data size

(note 2)

1

DL_TFC1

UL_TFC1

DL_TFC0, DL_TFC3, UL_TFC0, UL_TFC3

UL_TFC0, UL_TFC1,

UL_TFC2, UL_TFC3,

UL_TFC4

RB5: 39 bits

RB6: 53 bits

RB5: 39 bits

RB6: No data

2

DL_TFC2

UL_TFC2

DL_TFC0, DL_TFC3, UL_TFC0, UL_TFC3

UL_TFC0, UL_TFC1, UL_TFC2,

UL_TFC3, UL_TFC5,

RB5: 42 bits

RB6: 53 bits

RB5: 42 bits

RB6: 53 bits

NOTE 1: UL_TFC0, UL_TFC1, UL_TFC2 and UL_TFC3 are part of minimum set of TFCIs.

NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs.

See clause 18.3.1.1 for test procedure.

18.3.2.11.4 Test requirements

See clause 18.3.1.1 for definition of step 10 and step 15.

1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.

2. At step 15 the UE transmitted transport format shall be

– for sub-test 1: RB5/TF1 (1×39).

– for sub-test 2: RB5/TF2 (1×42) and RB6/TF1 (1×53).

3. At step 15 the UE shall return

– for sub-test 1: an RLC SDU on RB5 having the same content as sent by SS; and no data shall be received on RB6.

– for sub-test 2: an RLC SDU on each of RB5 and RB6 having the same content as sent by SS

18.3.2.12 Conversational / unknown / UL:28.8 DL:28.8 kbps / CS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH

18.3.2.12.1 Conformance requirement

See 18.3.2.4.1.

18.3.2.12.2 Test purpose

To verify radio bearer establishment and correct data transfer for reference radio bearer configuration as specified in TS 34.108, clause 6.11.6.4.1.12.

18.3.2.12.3 Method of test

Uplink RLC

TM RLC

Segmentation indication

FALSE

Downlink RLC

TM RLC

Segmentation indication

FALSE

Uplink TFS:

TFI

RB5

(28.8 kbps)

DCCH

TFS

TF0, bits

0x576

0x148

TF1, bits

1×576

1×148

Uplink TFCS:

TFCI

(RB5, DCCH)

UL_TFC0

(TF0, TF0)

UL_TFC1

(TF1, TF0)

UL_TFC2

(TF0, TF1)

UL_TFC3

(TF1, TF1)

Downlink TFS:

RB5

(28.8 kbps)

DCCH

TFS

TF0, bits

0x576

0x148

TF1, bits

1×576

1×148

Downlink TFCS:

TFCI

(RB5, DCCH)

DL_TFC0

(TF0, TF0)

DL_TFC1

(TF1, TF0)

DL_TFC2

(TF0, TF1)

DL_TFC3

(TF1, TF1)

Sub-tests:

Sub-test

Downlink TFCS

under test

Uplink TFCS

Under test

Implicitly tested

Restricted UL TFCIs

(note 1)

UL RLC SDU size

(bits)

(note2 )

Test data size

(bits)

(note 2)

1

DL_TFC1

UL_TFC1

DL_TFC0, DL_TFC2, UL_TFC0, UL_TFC2

UL_TFC0, UL_TFC1,

UL_TFC2,

UL_TFC3

RB5: 576

RB5: 576

NOTE 1: UL_TFC0, UL_TFC1 and UL_TFC2 are part of minimum set of TFCIs.

NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs.

See clause 18.3.1.1 for test procedure.

18.3.2.12.4 Test requirements

See clause 18.3.1.1 for definition of step 10 and step 15.

1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.

2. At step 15 the UE transmitted transport format shall be

– for sub-test 1: RB5/TF1 (1×576).

3. At step 15 the UE shall return

– for sub-test 1: an RLC SDU on RB5 having the same content as sent by SS.

18.3.2.13 Conversational / unknown / UL:64 DL:64 kbps / CS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH

18.3.2.13.1 Conversational / unknown / UL:64 DL:64 kbps / CS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH / 20ms TTI

18.3.2.13.1.1 Conformance requirement

See clause 18.3.2.4.1.

18.3.2.13.1.2 Test purpose

To verify radio bearer establishment and correct data transfer for reference radio bearer configuration as specified in TS 34.108, clause 6.11.6.4.1.13.

18.3.2.13.1.3 Method of test

Initial Conditions

The following RLC Info parameter values shall be set by the SS:

Uplink RLC

TM RLC

Transmission RLC discard

CHOICE SDU Discard Mode

Timer based no explicit

Timer_discard

100ms

Segmentation indication

FALSE

Downlink RLC

TM RLC

Segmentation indication

FALSE

NOTE: Timer based discard without explicit signalling is used in uplink to secure that the UE will be able to return data for the case when the UE test loop function will not deliver all the SDUs in one and the same TTI .

Uplink TFS:

TFI

RB5

(64 kbps)

DCCH

TFS

TF0, bits

0x640

0x148

TF1, bits

2×640

1×148

Uplink TFCS:

TFCI

(RB5, DCCH)

UL_TFC0

(TF0, TF0)

UL_TFC1

(TF1, TF0)

UL_TFC2

(TF0, TF1)

UL_TFC3

(TF1, TF1)

Downlink TFS:

TFI

RB5

(64 kbps)

DCCH

TFS

TF0, bits

0x640

0x148

TF1, bits

2×640

1×148

Downlink TFCS:

TFCI

(RB5, DCCH)

DL_TFC0

(TF0, TF0)

DL_TFC1

(TF1, TF0)

DL_TFC2

(TF0, TF1)

DL_TFC3

(TF1, TF1)

Sub-tests:

Sub-test

Downlink TFCS

Under test

Uplink TFCS

Under test

Implicitly tested

Restricted UL TFCIs

(note 1)

UL RLC SDU size

(bits)

(note 2)

Test data size

(bits)

(note 2)

1

DL_TFC1

UL_TFC1

DL_TFC0, DL_TFC2, UL_TFC0, UL_TFC2

UL_TFC0, UL_TFC1,

UL_TFC2,

UL_TFC3

RB5: 640

RB5: 2×640

NOTE 1: UL_TFC0, UL_TFC1, and UL_TFC2 are part of minimum set of TFCIs.

NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs.

See clause 18.3.1.1 for test procedure.

18.3.2.13.1.4 Test requirements

See clause 18.3.1.1 for definition of step 10 and step 15.

1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.

2. At step 15 the UE transmitted transport format shall be

– for sub-test 1: RB5/TF1 (2×640).

3. At step 15 the UE shall return

– for sub-test 1: two RLC SDUs on RB5 having the same content as sent by SS.

18.3.2.13.2 Conversational / unknown / UL:64 DL:64 kbps / CS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH / 40ms TTI

18.3.2.13.2.1 Conformance requirement

See clause 18.3.2.4.1.

18.3.2.13.2.2 Test purpose

To verify radio bearer establishment and correct data transfer for reference radio bearer configuration as specified in TS 34.108, clause 6.11.6.4.1.13.

18.3.2.13.2.3 Method of test

Initial Conditions

The following RLC Info parameter values shall be set by the SS:

Uplink RLC

TM RLC

Transmission RLC discard

CHOICE SDU Discard Mode

Timer based no explicit

Timer_discard

100ms

Segmentation indication

FALSE

Downlink RLC

TM RLC

Segmentation indication

FALSE

NOTE: Timer based discard without explicit signalling is used in uplink to secure that the UE will be able to return data for the case when the UE test loop function will not deliver all the SDUs in one and the same TTI .

Uplink TFS:

TFI

RB5

(64 kbps)

DCCH

TFS

TF0, bits

0x640

0x148

TF1, bits

4×640

1×148

Uplink TFCS:

TFCI

(RB5, DCCH)

UL_TFC0

(TF0, TF0)

UL_TFC1

(TF1, TF0)

UL_TFC2

(TF0, TF1)

UL_TFC3

(TF1, TF1)

Downlink TFS:

TFI

RB5

(64 kbps)

DCCH

TFS

TF0, bits

0x640

0x148

TF1, bits

4×640

1×148

Downlink TFCS:

TFCI

(RB5, DCCH)

DL_TFC0

(TF0, TF0)

DL_TFC1

(TF1, TF0)

DL_TFC2

(TF0, TF1)

DL_TFC3

(TF1, TF1)

Sub-tests:

Sub-test

Downlink TFCS

Under test

Uplink TFCS

Under test

Implicitly tested

Restricted UL TFCIs

(note 1)

UL RLC SDU size

(bits)

(note 2)

Test data size

(bits)

(note 2)

1

DL_TFC1

UL_TFC1

DL_TFC0, DL_TFC2, UL_TFC0, UL_TFC2

UL_TFC0, UL_TFC1,

UL_TFC2,

UL_TFC3

RB5: 640

RB5: 4×640

NOTE 1: UL_TFC0, UL_TFC1, and UL_TFC2 are part of minimum set of TFCIs.

NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs.

See clause 18.3.1.1 for test procedure.

18.3.2.13.2.4 Test requirements

See clause 18.3.1.1 for definition of step 10 and step 15.

1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.

2. At step 15 the UE transmitted transport format shall be

– for sub-test 1: RB5/TF1 (4×640).

3. At step 15 the UE shall return

– for sub-test 1: four RLC SDUs on RB5 having the same content as sent by SS.

18.3.2.14 Conversational / unknown / UL:32 DL:32 kbps / CS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH

18.3.2.14.1 Conversational / unknown / UL:32 DL:32 kbps / CS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH / 20ms TTI

18.3.2.14.1.1 Conformance requirement

See 18.3.2.4.1.

18.3.2.14.1.2 Test purpose

To verify radio bearer establishment and correct data transfer for reference radio bearer configuration as specified in TS 34.108, clause 6.11.6.4.1.14.

18.3.2.14.1.3 Method of test

Initial Conditions

The following RLC Info parameter values shall be set by the SS:

Uplink RLC

TM RLC

Segmentation indication

FALSE

Downlink RLC

TM RLC

Segmentation indication

FALSE

Uplink TFS:

TFI

RB5

(32 kbps)

DCCH

TFS

TF0, bits

0x640

0x148

TF1, bits

1×640

1×148

Uplink TFCS:

TFCI

(RB5, DCCH)

UL_TFC0

(TF0, TF0)

UL_TFC1

(TF1, TF0)

UL_TFC2

(TF0, TF1)

UL_TFC3

(TF1, TF1)

Downlink TFS:

TFI

RB5

(32 kbps)

DCCH

TFS

TF0, bits

0x640

0x148

TF1, bits

1×640

1×148

Downlink TFCS:

TFCI

(RB5, DCCH)

DL_TFC0

(TF0, TF0)

DL_TFC1

(TF1, TF0)

DL_TFC2

(TF0, TF1)

DL_TFC3

(TF1, TF1)

Sub-tests:

Sub-test

Downlink TFCS

Under test

Uplink TFCS

Under test

Implicitly tested

Restricted UL TFCIs

(note 1)

UL RLC SDU size

(bits)

(note 2)

Test data size

(bits)

(note 2)

1

DL_TFC1

UL_TFC1

DL_TFC0, DL_TFC2, UL_TFC0, UL_TFC2

UL_TFC0, UL_TFC1,

UL_TFC2,

UL_TFC3

RB5: 640

RB5: 640

NOTE 1: UL_TFC0, UL_TFC1, and UL_TFC2 are part of minimum set of TFCIs.

NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs.

See 18.3.1.1 for test procedure.

18.3.2.14.1.4 Test requirements

1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.

2. At step 15 the UE transmitted transport format shall be

– for sub-test 1: RB5/TF1 (1×640).

3. At step 15 the UE shall return

– for sub-test 1: an RLC SDU on RB5 having the same content as sent by SS.

18.3.2.14.1 Conversational / unknown / UL:32 DL:32 kbps / CS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH / 40ms TTI

18.3.2.14.1.1 Conformance requirement

See 18.3.2.4.1.

18.3.2.14.1.2 Test purpose

To verify radio bearer establishment and correct data transfer for reference radio bearer configuration as specified in TS 34.108, clause 6.11.6.4.1.14.

18.3.2.14.1.3 Method of test

Initial Conditions

The following RLC Info parameter values shall be set by the SS:

Uplink RLC

TM RLC

Segmentation indication

FALSE

Downlink RLC

TM RLC

Segmentation indication

FALSE

Uplink TFS:

TFI

RB5

(32 kbps)

DCCH

TFS

TF0, bits

0x640

0x148

TF1, bits

2×640

1×148

Uplink TFCS:

TFCI

(RB5, DCCH)

UL_TFC0

(TF0, TF0)

UL_TFC1

(TF1, TF0)

UL_TFC2

(TF0, TF1)

UL_TFC3

(TF1, TF1)

Downlink TFS:

TFI

RB5

(32 kbps)

DCCH

TFS

TF0, bits

0x640

0x148

TF1, bits

2×640

1×148

Downlink TFCS:

TFCI

(RB5, DCCH)

DL_TFC0

(TF0, TF0)

DL_TFC1

(TF1, TF0)

DL_TFC2

(TF0, TF1)

DL_TFC3

(TF1, TF1)

Sub-tests:

Sub-test

Downlink TFCS

Under test

Uplink TFCS

Under test

Implicitly tested

Restricted UL TFCIs

(note 1)

UL RLC SDU size

(bits)

(note 2)

Test data size

(bits)

(note 2)

1

DL_TFC1

UL_TFC1

DL_TFC0, DL_TFC2, UL_TFC0, UL_TFC2

UL_TFC0, UL_TFC1,

UL_TFC2,

UL_TFC3

RB5: 640

RB5: 2×640

NOTE 1: UL_TFC0, UL_TFC1, and UL_TFC2 are part of minimum set of TFCIs.

NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs.

See 18.3.1.1 for test procedure.

18.3.2.14.1.4 Test requirements

1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.

2. At step 15 the UE transmitted transport format shall be

– for sub-test 1: RB5/TF1 (2×640).

3. At step 15 the UE shall return

– for sub-test 1: two RLC SDUs on RB5 having the same content as sent by SS.

18.3.2.15 Streaming / unknown / UL:14.4/DL:14.4 kbps / CS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH

18.3.2.15.1 Conformance requirement

See 18.3.2.4.1.

18.3.2.15.2 Test purpose

To verify radio bearer establishment and correct data transfer for reference radio bearer configuration as specified in TS 34.108, clause 6.11.6.4.1.15.

18.3.2.15.3 Method of test

Uplink TFS:

TFI

RB5

(14.4 kbps)

DCCH

TFS

TF0, bits

0x576

0x148

TF1, bits

1×576

1×148

Uplink TFCS:

TFCI

(RB5, DCCH)

UL_TFC0

(TF0, TF0)

UL_TFC1

(TF1, TF0)

UL_TFC2

(TF0, TF1)

UL_TFC3

(TF1, TF1)

Downlink TFS:

TFI

RB5

(14.4 kbps)

DCCH

TFS

TF0, bits

0x576

0x148

TF1, bits

1×576

1×148

Downlink TFCS:

TFCI

(RB5, DCCH)

DL_TFC0

(TF0, TF0)

DL_TFC1

(TF1, TF0)

DL_TFC2

(TF0, TF1)

DL_TFC3

(TF1, TF1)

Sub-tests:

Sub-test

Downlink TFCS

Under test

Uplink TFCS

Under test

Implicitly tested

Restricted UL TFCIs

(note 1)

UL RLC SDU size

(bits)

(note 2)

Test data size

(bits)

(note 2)

1

DL_TFC1

UL_TFC1

DL_TFC0, DL_TFC2, UL_TFC0, UL_TFC2

UL_TFC0, UL_TFC1,

UL_TFC2,

UL_TFC3

RB5: 576

RB5: 576

NOTE 1: UL_TFC0, UL_TFC1, and UL_TFC2 are part of minimum set of TFCIs.

NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs.

See 18.3.1.1 for test procedure.

18.3.2.15.4 Test requirements

See 18.3.1.1 for definition of step 10 and step 15.

1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.

2. At step 15 the UE transmitted transport format shall be

– for sub-test 1: RB5/TF1 (1×576).

3. At step 15 the UE shall return

– for sub-test 1: an RLC SDU on RB5 having the same content as sent by SS.

18.3.2.16 Streaming / unknown / UL:28.8/DL:28.8 kbps / CS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH

18.3.2.16.1 Conformance requirement

See 18.3.2.4.1.

18.3.2.16.2 Test purpose

To verify radio bearer establishment and correct data transfer for reference radio bearer configuration as specified in TS 34.108, clause 6.11.6.4.1.16.

18.3.2.16.3 Method of test

Uplink TFS:

TFI

RB5

(28.8 kbps)

DCCH

TFS

TF0, bits

0x576

0x148

TF1, bits

1×576

1×148

Uplink TFCS:

TFCI

(RB5, DCCH)

UL_TFC0

(TF0, TF0)

UL_TFC1

(TF1, TF0)

UL_TFC2

(TF0, TF1)

UL_TFC3

(TF1, TF1)

Downlink TFS:

RB5

(28.8 kbps)

DCCH

TFS

TF0, bits

0x576

0x148

TF1, bits

1×576

1×148

Downlink TFCS:

TFCI

(RB5, DCCH)

DL_TFC0

(TF0, TF0)

DL_TFC1

(TF1, TF0)

DL_TFC2

(TF0, TF1)

DL_TFC3

(TF1, TF1)

Sub-tests:

Sub-test

Downlink TFCS

Under test

Uplink TFCS

Under test

Implicitly tested

Restricted UL TFCIs

(note 1)

UL RLC SDU size

(bits)

(note 2)

Test data size

(bits)

(note 2)

1

DL_TFC1

UL_TFC1

DL_TFC0, DL_TFC2, UL_TFC0, UL_TFC2

UL_TFC0, UL_TFC1,

UL_TFC2,

UL_TFC3

RB5: 576

RB5: 576

NOTE 1: UL_TFC0, UL_TFC1 and UL_TFC2 are part of minimum set of TFCIs.

NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs.

See 18.3.1.1 for test procedure.

18.3.2.16.4 Test requirements

See 18.3.1.1 for definition of step 10 and step 15.

1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.

2. At step 15 the UE transmitted transport format shall be

– for sub-test 1: RB5/TF1 (1×576).

3. At step 15 the UE shall return

– for sub-test 1: an RLC SDU on RB5 having the same content as sent by SS.

18.3.2.17 Streaming / unknown / UL:57.6/DL:57.6 kbps / CS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH

18.3.2.17.1 Conformance requirement

See 18.3.2.4.1.

18.3.2.17.2 Test purpose

To verify radio bearer establishment and correct data transfer for reference radio bearer configuration as specified in TS 34.108, clause 6.11.6.4.1.17.

18.3.2.17.3 Method of test

Initial Conditions

The following RLC Info parameter values shall be set by the SS:

Uplink RLC

TM RLC

Transmission RLC discard

CHOICE SDU Discard Mode

Timer based no explicit

Timer_discard

100ms

Segmentation indication

FALSE

Downlink RLC

TM RLC

Segmentation indication

FALSE

NOTE: Timer based discard without explicit signalling is used in uplink to secure that the UE will be able to return data for the case when the UE test loop function will not deliver all the SDUs in one and the same TTI .

Uplink TFS:

TFI

RB5

(57.6 kbps)

DCCH

TFS

TF0, bits

0x576

0x148

TF1, bits

1×576

1×148

TF2, bits

2×576

N/A

TF3, bits

3×576

N/A

TF4, bits

4×576

N/A

Uplink TFCS:

TFCI

(RB5, DCCH)

UL_TFC0

(TF0, TF0)

UL_TFC1

(TF1, TF0)

UL_TFC2

(TF2, TF0)

UL_TFC3

(TF3, TF0)

UL_TFC4

(TF4, TF0)

UL_TFC5

(TF0, TF1)

UL_TFC6

(TF1, TF1)

UL_TFC7

(TF2, TF1)

UL_TFC8

(TF3, TF1)

UL_TFC9

(TF4, TF1)

Downlink TFS:

TFI

RB5

(57.6 kbps)

DCCH

TFS

TF0, bits

0x576

0x148

TF1, bits

1×576

1×148

TF2, bits

2×576

N/A

TF3, bits

3×576

N/A

TF4, bits

4×576

N/A

Downlink TFCS:

TFCI

(RB5, DCCH)

DL_TFC0

(TF0, TF0)

DL_TFC1

(TF1, TF0)

DL_TFC2

(TF2, TF0)

DL_TFC3

(TF3, TF0)

DL_TFC4

(TF4, TF0)

DL_TFC5

(TF0, TF1)

DL_TFC6

(TF1, TF1)

DL_TFC7

(TF2, TF1)

DL_TFC8

(TF3, TF1)

DL_TFC9

(TF4, TF1)

Sub-tests:

Sub-test

Downlink TFCS

Under test

Uplink TFCS

Under test

Implicitly tested

Restricted UL TFCIs

UL RLC SDU size

(bits)

(note)

Test data size

(bits)

(note)

1

DL_TFC1

UL_TFC1

DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5,

UL_TFC0, UL_TFC1,

UL_TFC5,

UL_TFC6

RB5: 576

RB5: 576

2

DL_TFC2

UL_TFC2

DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,

UL_TFC2,

UL_TFC5,

UL_TFC7

RB5: 576

RB5: 2×576

3

DL_TFC3

UL_TFC3

DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,

UL_TFC3,

UL_TFC5,

UL_TFC8

RB5: 576

RB5: 3×576

4

DL_TFC4

UL_TFC4

DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,

UL_TFC4,

UL_TFC5,

UL_TFC9

RB5: 576

RB5: 4×576

NOTE 1: UL_TFC0, UL_TFC1 and UL_TFC5 are part of minimum set of TFCIs.

NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs.

See 18.3.1.1 for test procedure.

18.3.2.17.4 Test requirements

See 18.3.1.1 for definition of step 10 and step 15.

1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.

2. At step 15 the UE transmitted transport format shall be

– for sub-test 1: RB5/TF1 (1×576).

– for sub-test 2: RB5/TF2 (2×576) or RB5/TF1 (1×576).

– for sub-test 3: RB5/TF3 (3×576) or RB5/TF1 (1×576).

– for sub-test 4: RB5/TF4 (4×576) or RB5/TF1 (1×576).

3. At step 15 the UE shall return

– for sub-test 1: one RLC SDU on RB5 having the same content as sent by SS.

– for sub-test 2: two RLC SDU on RB5 having the same content as sent by SS.

– for sub-test 3: three RLC SDU on RB5 having the same content as sent by SS.

– for sub-test 4: four RLC SDU on RB5 having the same content as sent by SS.

18.3.2.18 Void

18.3.2.19 Void

18.3.2.20 Void

18.3.2.21 Void

18.3.2.22 Void

18.3.2.23 Interactive or background / UL:32 DL:8 kbps / PS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH

18.3.2.23.1 Interactive or background / UL:32 DL:8 kbps / PS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH / (PS RAB payload size 320)

18.3.2.23.1.1 Conformance requirement

See 18.3.2.4.1.

18.3.2.23.1.2 Test purpose

Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.11.6.4.1.23 for uplink payload size 320 case.

18.3.2.23.1.3 Method of test

Uplink TFS:

TFI

RB5

(32 kbps)

DCCH

TFS

TF0, bits

0x336

0x148

TF1, bits

1×336

1×148

TF2, bits

2×336

N/A

Uplink TFCS:

TFCI

(RB5, DCCH)

UL_TFC0

(TF0, TF0)

UL_TFC1

(TF1, TF0)

UL_TFC2

(TF2, TF0)

UL_TFC3

(TF0, TF1)

UL_TFC4

(TF1, TF1)

UL_TFC5

(TF2, TF1)

Downlink TFS:

TFI

RB5

(8 kbps)

DCCH

TFS

TF0, bits

0x336

0x148

TF1, bits

1×336

1×148

Downlink TFCS:

TFCI

(RB5, DCCH)

DL_TFC0

(TF0, TF0)

DL_TFC1

(TF1, TF0)

DL_TFC2

(TF0, TF1)

DL_TFC3

(TF1, TF1)

Sub-tests:

Sub-test

Downlink TFCS

Under test

Uplink TFCS

Under test

Implicitly tested

Restricted UL TFCIs

(note 1)

UL RLC SDU size

(bits)

(note 2)

Test data size

(bits)

(note 2)

1

DL_TFC1

UL_TFC1

DL_TFC0, DL_TFC2, UL_TFC0, UL_TFC3

UL_TFC0, UL_TFC1,

UL_TFC3,

UL_TFC4

RB5: 312

RB5: 312

2

DL_TFC1

UL_TFC2

DL_TFC0, DL_TFC2, UL_TFC0, UL_TFC3

UL_TFC0, UL_TFC1, UL_TFC2,

UL_TFC3,

UL_TFC5

RB5: 632

RB5: 632

NOTE 1: UL_TFC0, UL_TFC1, and UL_TFC3 are part of minimum set of TFCIs.

NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs.

See 18.3.1.1 for test procedure.

18.3.2.23.1.4 Test requirements

See 18.3.1.1 for definition of step 10 and step 15.

1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.

2. At step 15 the UE transmitted transport format shall be

– for sub-test 1: RB5/TF1 (1×336).

– for sub-test 2: RB5/TF2 (2×336).

3. At step 15 the UE shall return

– for sub-test 1 and 2: an RLC SDU on RB5 having the same content as the DL RLC SDU sent by the SS.

18.3.2.23.2 Interactive or background / UL:32 DL:8 kbps / PS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH / (PS RAB payload size 128)

18.3.2.23.2.1 Conformance requirement

See 18.3.2.4.1.

18.3.2.23.2.2 Test purpose

Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.11.6.4.1.23 for the uplink payload size 128 case.

18.3.2.23.2.3 Method of test

Uplink TFS:

TFI

RB5

(32 kbps)

DCCH

TFS

TF0, bits

0x144

0x148

TF1, bits

1×144

1×148

TF2, bits

5×144

N/A

Uplink TFCS:

TFCI

(RB5, DCCH)

UL_TFC0

(TF0, TF0)

UL_TFC1

(TF1, TF0)

UL_TFC2

(TF2, TF0)

UL_TFC3

(TF0, TF1)

UL_TFC4

(TF1, TF1)

UL_TFC5

(TF2, TF1)

Downlink TFS:

TFI

RB5

(8 kbps)

DCCH

TFS

TF0, bits

0x336

0x148

TF1, bits

1×336

1×148

Downlink TFCS:

TFCI

(RB5, DCCH)

DL_TFC0

(TF0, TF0)

DL_TFC1

(TF1, TF0)

DL_TFC2

(TF0, TF1)

DL_TFC3

(TF1, TF1)

Sub-tests:

Sub-test

Downlink TFCS

Under test

Uplink TFCS

Under test

Implicitly tested

Restricted UL TFCIs

(note 1)

UL RLC SDU size

(bits)

(note 2)

Test data size

(bits)

(note 2)

1

DL_TFC1

UL_TFC1

DL_TFC0, DL_TFC2, UL_TFC0, UL_TFC3

UL_TFC0, UL_TFC1,

UL_TFC3,

UL_TFC4

RB5: 376

RB5: 312

2

DL_TFC1

UL_TFC2

DL_TFC0, DL_TFC2, UL_TFC0, UL_TFC3

UL_TFC0, UL_TFC1, UL_TFC2,

UL_TFC3,

UL_TFC5

RB5: 632

RB5: 312

NOTE 1: UL_TFC0, UL_TFC1, and UL_TFC3 are part of minimum set of TFCIs.

NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs.

See 18.3.1.1 for test procedure.

18.3.2.23.2.4 Test requirements

See 18.3.1.1 for definition of step 10 and step 15.

1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.

2. At step 15 the UE transmitted transport format shall be

– for sub-test 1: RB5/TF1 (1×144).

– for sub-test 2: RB5/TF2 (5×144).

3. At step 15 the UE shall return

– for sub-test 1: an RLC SDU on RB5 having the same content as 1 times plus 64 lsb’s of the DL RLC SDU sent by the SS.

– for sub-test 2: an RLC SDU on RB5 having the same content as 2 times plus 8 lsb’s of the DL RLC SDU sent by the SS.

18.3.2.23a Interactive or background / UL:8 DL:8 kbps / PS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH.

18.3.2.23a.1 Interactive or background / UL:8 DL:8 kbps / PS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH / 40 ms TTI

18.3.2.23a.1.1 Conformance requirement

See 18.3.2.4.1.

18.3.2.23a.1.2 Test purpose

Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.11.6.4.1.23a, for the uplink 40 ms TT case.

18.3.2.23a.1.3 Method of test

See 18.3.1.1 for test procedure.

Uplink TFS:

TFI

RB5

(8 kbps)

DCCH

TFS

TF0, bits

0x336

0x148

TF1, bits

1×336

1×148

Uplink TFCS:

TFCI

(8 kbps RAB, DCCH)

UL_TFC0

(TF0, TF0)

UL_TFC1

(TF1, TF0)

UL_TFC2

(TF0, TF1)

UL_TFC3

(TF1, TF1)

Downlink TFS:

RB5

(8 kbps)

DCCH

TFS

TF0, bits

0x336

0x148

TF1, bits

1×336

1×148

Downlink TFCS:

TFCI

(8 kbps RAB, DCCH)

DL_TFC0

(TF0, TF0)

DL_TFC1

(TF1, TF0)

DL_TFC2

(TF0, TF1)

DL_TFC3

(TF1, TF1)

Sub-tests:

Sub-test

Downlink TFCS

Under

Test

Uplink TFCS

Under test

Implicitly tested

Restricted UL TFCIs

(note 1)

UL RLC SDU size

(bits)

(note 2)

Test data size

(bits)

(note 2)

1

DL_TFC1

UL_TFC1

DL_TFC0, DL_TFC2,

UL_TFC0, UL_TFC2,

UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3

RB5: 312

RB5: 312

NOTE 1: UL_TFC0, UL_TFC1, and UL_TFC2 are part of minimum set of TFCIs.

NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs.

RB5: Test data size has been set to DL TFS size under test minus 8 bits (size of 7 bit length indicator and expansion bit). The UL RLC SDU size has been set equal to the uplink TFS size under test minus 8 bits (size of 7 bit length indicator and expansion bit).

18.3.2.23a.1.4 Test requirements

See 18.3.1.1 for definition of step 10 and step 15.

1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.

2. At step 15 the UE transmitted transport format shall be

– for sub-test 1: RB5/TF1 (1×336).

3. At step 15 the UE shall return

– for sub-test 1: an RLC SDU on RB5 having the same content as the DL RLC SDU sent by the SS.

18.3.2.23a.2 Interactive or background / UL:8 DL:8 kbps / PS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH / 80 ms TTI

Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.11.6.4.1.23a, for the uplink 80 ms TTI case.

See test case 18.3.2.23.2 for test procedure and test requirement.

18.3.2.23b Interactive or background / UL:16 DL:16 kbps / PS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH.

18.3.2.23b.1 Interactive or background / UL:16 DL:16 kbps / PS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH / Payload size 320.

18.3.2.23b.1.1 Conformance requirement

See clause 18.3.2.4.1.

18.3.2.23b.1.2 Test purpose

Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.11.6.4.1.23b, for the uplink payload size 320 case.

18.3.2.23b.1.3 Method of test

Uplink TFS:

TFI

RB5

(16 kbps)

DCCH

TFS

TF0, bits

0x336

0x148

TF1, bits

1×336

1×148

TF2, bits

2×336

N/A

Uplink TFCS:

TFCI

(RB5, DCCH)

UL_TFC0

(TF0, TF0)

UL_TFC1

(TF1, TF0)

UL_TFC2

(TF2, TF0)

UL_TFC3

(TF0, TF1)

UL_TFC4

(TF1, TF1)

UL_TFC5

(TF2, TF1)

Downlink TFS:

TFI

RB5

(32 kbps)

DCCH

TFS

TF0, bits

0x336

0x148

TF1, bits

1×336

1×148

TF2, bits

2×336

N/A

Downlink TFCS:

TFCI

(RB5, DCCH)

DL_TFC0

(TF0, TF0)

DL_TFC1

(TF1, TF0)

DL_TFC2

(TF2, TF0)

DL_TFC3

(TF0, TF1)

DL_TFC4

(TF1, TF1)

DL_TFC5

(TF2, TF1)

Sub-tests:

Sub-test

Downlink TFCS

Under test

Uplink TFCS

Under test

Implicitly tested

Restricted UL TFCIs

(note 1)

UL RLC SDU size

(bits)

(note 2)

Test data size

(bits)

(note 2)

1

DL_TFC1

UL_TFC1

DL_TFC0, UL_TFC0

DL_TFC3,UL_TFC3

UL_TFC0, UL_TFC1,

UL_TFC3,

UL_TFC4

RB5: 312

RB5: 312

2

DL_TFC2

UL_TFC2

DL_TFC0, UL_TFC0

DL_TFC3 ,UL_TFC3

UL_TFC0, UL_TFC1,

UL_TFC2,

UL_TFC3,

UL_TFC5

RB5: 632

RB5: 632

NOTE 1: UL_TFC0, UL_TFC1 and UL_TFC3 are part of minimum set of TFCIs.

NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs.
RB5: Test data size has been set to the payload size of the DL TF under test minus 8 bits (size of 7 bit length indicator and expansion bit). The UL RLC SDU size has been set equal to the size of the payload size of the UL TF under test minus 8 bits (the size of 7 bit length indicator and expansion bit).

See 18.3.1.1 for test procedure.

18.3.2.23b.1.4 Test requirements

See 18.3.1.1 for definition of step 10 and step 15.

1. At step 10 the UE shall send a RADIO BEARER SETUP COMPLETE message.

2. At step 15 the UE transmitted transport format shall be

– for sub-test 1: RB5/TF1 (1×336).

– for sub-test 2: RB5/TF2 (2×336) or RB5/TF1 (1×336).

3. At step 15 the UE shall return

– for sub-test 1 and 2: an RLC SDU on RB5 having the same content as sent by the SS.

18.3.2.23b.2 Interactive or background / UL:16 DL:16 kbps / PS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH / Payload size 128.

18.3.2.23b.2.1 Conformance requirement

See clause 18.3.2.4.1.

18.3.2.23b.2.2 Test purpose

Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.11.6.4.1.23b, for the uplink payload size 128 case.

18.3.2.23b.2.3 Method of test

Uplink TFS:

TFI

RB5

(16 kbps)

DCCH

TFS

TF0, bits

0x144

0x148

TF1, bits

1×144

1×148

TF2, bits

5×144

N/A

Uplink TFCS:

TFCI

(RB5, DCCH)

UL_TFC0

(TF0, TF0)

UL_TFC1

(TF1, TF0)

UL_TFC2

(TF2, TF0)

UL_TFC3

(TF0, TF1)

UL_TFC4

(TF1, TF1)

UL_TFC5

(TF2, TF1)

Downlink TFS:

TFI

RB5

(32 kbps)

DCCH

TFS

TF0, bits

0x336

0x148

TF1, bits

1×336

1×148

TF2, bits

2×336

N/A

Downlink TFCS:

TFCI

(RB5, DCCH)

DL_TFC0

(TF0, TF0)

DL_TFC1

(TF1, TF0)

DL_TFC2

(TF2, TF0)

DL_TFC3

(TF0, TF1)

DL_TFC4

(TF1, TF1)

DL_TFC5

(TF2, TF1)

Sub-tests:

Sub-test

Downlink TFCS

Under test

Uplink TFCS

Under test

Implicitly tested

Restricted UL TFCIs

(note 1)

UL RLC SDU size

(bits)

(note 2)

Test data size

(bits)

(note 2)

1

DL_TFC1

UL_TFC1

DL_TFC0, UL_TFC0

DL_TFC3,UL_TFC3

UL_TFC0, UL_TFC1,

UL_TFC3,

UL_TFC4

RB5: 376

RB5: 312

2

DL_TFC2

UL_TFC2

DL_TFC0, UL_TFC0

DL_TFC3 ,UL_TFC3

UL_TFC0, UL_TFC1,

UL_TFC2,

UL_TFC3,

UL_TFC5

RB5: 632

RB5: 632

NOTE 1: UL_TFC0, UL_TFC1 and UL_TFC3 are part of minimum set of TFCIs.

NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs.
RB5: Test data size has been set to the payload size of the DL TF under test minus 8 bits (size of 7 bit length indicator and expansion bit). The UL RLC SDU size has been set equal to the size of the payload size of the UL TF under test minus 8 bits (the size of 7 bit length indicator and expansion bit).

See 18.3.1.1 for test procedure.

18.3.2.23b.2.4 Test requirements

See 18.3.1.1 for definition of step 10 and step 15.

1. At step 10 the UE shall send a RADIO BEARER SETUP COMPLETE message.

2. At step 15 the UE transmitted transport format shall be

– for sub-test 1: RB5/TF1 (1×144).

– for sub-test 2: RB5/TF2 (5×144).

3. At step 15 the UE shall return

– for sub-test 1: an RLC SDU on RB5 having the same content as 1 times plus 64 lsb’s of the DL RLC SDU sent by the SS.

– for sub-test 2: an RLC SDU on RB5 having the same content as sent by the SS.

18.3.2.23c Interactive or background / UL:32 DL:32 kbps / PS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH.

18.3.2.23c.1 Interactive or background / UL:32 DL:32 kbps / PS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH / Payload size 320.

18.3.2.23c.1.1 Conformance requirement

See 18.3.2.4.1.

18.3.2.23c.1.2 Test purpose

Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.11.6.4.1.23c the uplink payload size 320 case.

18.3.2.23c.1.3 Method of test

Uplink TFS:

TFI

RB5

(32 kbps)

DCCH

TFS

TF0, bits

0x336

0x148

TF1, bits

1×336

1×148

TF2, bits

2×336

N/A

TF3, bits

3×336

N/A

TF4, bits

4×336

N/A

Uplink TFCS:

TFCI

(RB5, DCCH)

UL_TFC0

(TF0, TF0)

UL_TFC1

(TF1, TF0)

UL_TFC2

(TF2, TF0)

UL_TFC3

(TF3, TF0)

UL_TFC4

(TF4, TF0)

UL_TFC5

(TF0, TF1)

UL_TFC6

(TF1, TF1)

UL_TFC7

(TF2, TF1)

UL_TFC8

(TF3, TF1)

UL_TFC9

(TF4, TF1)

Downlink TFS:

TFI

RB5

(32 kbps)

DCCH

TFS

TF0, bits

0x336

0x148

TF1, bits

1×336

1×148

TF2, bits

2×336

N/A

TF3, bits

3×336

N/A

TF4, bits

4×336

N/A

Downlink TFCS:

TFCI

(RB5, DCCH)

DL_TFC0

(TF0, TF0)

DL_TFC1

(TF1, TF0)

DL_TFC2

(TF2, TF0)

DL_TFC3

(TF3, TF0)

DL_TFC4

(TF4, TF0)

DL_TFC5

(TF0, TF1)

DL_TFC6

(TF1, TF1)

DL_TFC7

(TF2, TF1)

DL_TFC8

(TF3, TF1)

DL_TFC9

(TF4, TF1)

Sub-tests:

Sub-test

Downlink TFCS

Under test

Uplink TFCS

Under test

Implicitly tested

Restricted UL TFCIs

(note 1)

UL RLC SDU size

(bits)

(note 2)

Test data size

(bits)

(note 2)

1

DL_TFC1

UL_TFC1

DL_TFC0, UL_TFC0

DL_TFC5,UL_TFC5

UL_TFC0, UL_TFC1,

UL_TFC5,

UL_TFC6

RB5: 312

RB5: 312

2

DL_TFC2

UL_TFC2

DL_TFC0, UL_TFC0

DL_TFC5 ,UL_TFC5

UL_TFC0, UL_TFC1,

UL_TFC2,

UL_TFC5,

UL_TFC7

RB5: 632

RB5: 632

3

DL_TFC3

UL_TFC3

DL_TFC0, UL_TFC0

DL_TFC5 ,UL_TFC5

UL_TFC0, UL_TFC1,

UL_TFC3,

UL_TFC5,

UL_TFC8

RB5: 952

RB5: 952

4

DL_TFC4

UL_TFC4

DL_TFC0, UL_TFC0

DL_TFC5 ,UL_TFC5

UL_TFC0, UL_TFC1,

UL_TFC4,

UL_TFC5,

UL_TFC9

RB5: 1272

RB5: 1272

NOTE 1: UL_TFC0, UL_TFC1 and UL_TFC5 are part of minimum set of TFCIs.

NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs.

For RB5: Test data size has been set to the payload size of the DL TF under test minus 8 bits (size of 7 bit length indicator and expansion bit). The UL RLC SDU size has been set equal to the size of the payload size of the UL TF under test minus 8 bits (the size of 7 bit length indicator and expansion bit).

See 18.3.1.1 for test procedure.

18.3.2.23c.1.4 Test requirements

See 18.3.1.1 for definition of step 10 and step 15.

1. At step 10 the UE shall send a RADIO BEARER SETUP COMPLETE message.

2. At step 15 the UE transmitted transport format shall be

– for sub-test 1: RB5/TF1 (1×336).

– for sub-test 2: RB5/TF2 (2×336) or RB5/TF1 (1×336).

– for sub-test 3: RB5/TF3 (3×336) or RB5/TF1 (1×336).

– for sub-test 4: RB5/TF4 (4×336) or RB5/TF1 (1×336).

3. At step 15 the UE shall return

– for sub-test 1 to 4: an RLC SDU on RB5 having the same content as the DL RLC SDU sent by the SS.

18.3.2.23c.2 Interactive or background / UL:32 DL:32 kbps / PS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH / Payload size 128.

18.3.2.23c.2.1 Conformance requirement

See clause 18.3.2.4.1.

18.3.2.23c.2.2 Test purpose

Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.11.6.4.1.23c, for the uplink payload size 128 case.

18.3.2.23c.2.3 Method of test

Uplink TFS:

TFI

RB5

(16 kbps)

DCCH

TFS

TF0, bits

0x144

0x148

TF1, bits

1×144

1×148

TF2, bits

5×144

N/A

TF3, bits

7×144

N/A

TF4, bits

10×144

N/A

Uplink TFCS:

TFCI

(RB5, DCCH)

UL_TFC0

(TF0, TF0)

UL_TFC1

(TF1, TF0)

UL_TFC2

(TF2, TF0)

UL_TFC3

(TF3, TF0)

UL_TFC4

(TF4, TF0)

UL_TFC5

(TF0, TF1)

UL_TFC6

(TF1, TF1)

UL_TFC7

(TF2, TF1)

UL_TFC8

(TF3, TF1)

UL_TFC9

(TF4, TF1)

Downlink TFS:

TFI

RB5

(32 kbps)

DCCH

TFS

TF0, bits

0x336

0x148

TF1, bits

1×336

1×148

TF2, bits

2×336

N/A

TF3, bits

3×336

N/A

TF4, bits

4×336

N/A

Downlink TFCS:

TFCI

(RB5, DCCH)

DL_TFC0

(TF0, TF0)

DL_TFC1

(TF1, TF0)

DL_TFC2

(TF2, TF0)

DL_TFC3

(TF3, TF0)

DL_TFC4

(TF4, TF0)

DL_TFC5

(TF0, TF1)

DL_TFC6

(TF1, TF1)

DL_TFC7

(TF2, TF1)

DL_TFC8

(TF3, TF1)

DL_TFC9

(TF4, TF1)

Sub-tests:

Sub-test

Downlink TFCS

Under test

Uplink TFCS

Under test

Implicitly tested

Restricted UL TFCIs

(note 1)

UL RLC SDU size

(bits)

(note 2)

Test data size

(bits)

(note 2)

1

DL_TFC1

UL_TFC1

DL_TFC0, UL_TFC0

DL_TFC5,UL_TFC5

UL_TFC0, UL_TFC1,

UL_TFC5,

UL_TFC6

RB5: 376

RB5: 312

2

DL_TFC2

UL_TFC2

DL_TFC0, UL_TFC0

DL_TFC5 ,UL_TFC5

UL_TFC0, UL_TFC1,

UL_TFC2,

UL_TFC5,

UL_TFC7

RB5: 632

RB5: 632

3

DL_TFC3

UL_TFC3

DL_TFC0, UL_TFC0

DL_TFC5 ,UL_TFC5

UL_TFC0, UL_TFC1,

UL_TFC3,

UL_TFC5,

UL_TFC8

RB5: 1784

RB5: 952

4

DL_TFC4

UL_TFC4

DL_TFC0, UL_TFC0

DL_TFC5 ,UL_TFC5

UL_TFC0, UL_TFC1,

UL_TFC4,

UL_TFC5,

UL_TFC9

RB5: 1272

RB5: 1272

NOTE 1: UL_TFC0, UL_TFC1 and UL_TFC5 are part of minimum set of TFCIs.

NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs.

For RB5: Test data size has been set to the payload size of the DL TF under test minus 8 bits (size of 7 bit length indicator and expansion bit). The UL RLC SDU size has been set equal to the size of the payload size of the UL TF under test minus 8 bits (the size of 7 bit length indicator and expansion bit).

See 18.3.1.1 for test procedure.

18.3.2.23c.2.4 Test requirements

See 18.3.1.1 for definition of step 10 and step 15.

1. At step 10 the UE shall send a RADIO BEARER SETUP COMPLETE message.

2. At step 15 the UE transmitted transport format shall be

– for sub-test 1: RB5/TF1 (1×144).

– for sub-test 2: RB5/TF2 (5×144).

– for sub-test 3: RB5/TF2 (7×144).

– for sub-test 4: RB5/TF2 (10×144).

3. At step 15 the UE shall return

– for sub for sub-test 1: an RLC SDU on RB5 having the same content as 1 times plus 64 lsb’s of the DL RLC SDU sent by the SS.

– for sub-test 2: an RLC SDU on RB5 having the same content as sent by the SS.

– for sub-test 3: an RLC SDU on RB5 having the same content as 1 times plus 832 lsb’s of the DL RLC SDU sent by the SS.

– for sub-test 4: an RLC SDU on RB5 having the same content as sent by the SS.

18.3.2.23d Interactive or background / UL:32 DL:32 kbps / PS RAB (20 ms TTI) + UL:3.4 DL:3.4 kbps SRBs for DCCH.

18.3.2.23d.1 Interactive or background / UL:32 DL:32 kbps / PS RAB (20 ms TTI) + UL:3.4 DL:3.4 kbps SRBs for DCCH / Payload size 320.

18.3.2.23d.1.1 Conformance requirement

See 18.3.2.4.1.

18.3.2.23d.1.2 Test purpose

Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.11.6.4.1.23d, for the uplink payload size of 320 case.

18.3.2.23d.1.3 Method of test

Uplink TFS:

TFI

RB5

(32 kbps)

DCCH

TFS

TF0, bits

0x336

0x148

TF1, bits

1×336

1×148

TF2, bits

2×336

N/A

Uplink TFCS:

TFCI

(RB5, DCCH)

UL_TFC0

(TF0, TF0)

UL_TFC1

(TF1, TF0)

UL_TFC2

(TF2, TF0)

UL_TFC3

(TF0, TF1)

UL_TFC4

(TF1, TF1)

UL_TFC5

(TF2, TF1)

Downlink TFS:

TFI

RB5

(32 kbps)

DCCH

TFS

TF0, bits

0x336

0x148

TF1, bits

1×336

1×148

TF2, bits

2×336

N/A

Downlink TFCS:

TFCI

(RB5, DCCH)

DL_TFC0

(TF0, TF0)

DL_TFC1

(TF1, TF0)

DL_TFC2

(TF2, TF0)

DL_TFC3

(TF0, TF1)

DL_TFC4

(TF1, TF1)

DL_TFC5

(TF2, TF1)

Sub-tests:

Sub-test

Downlink TFCS

Under test

Uplink TFCS

Under test

Implicitly tested

Restricted UL TFCIs

(note 1)

UL RLC SDU size

(bits)

(note 2)

Test data size

(bits)

(note 2)

1

DL_TFC1

UL_TFC1

DL_TFC0, UL_TFC0

DL_TFC3,UL_TFC3

UL_TFC0, UL_TFC1,

UL_TFC3,

UL_TFC4

RB5: 312

RB5: 312

2

DL_TFC2

UL_TFC2

DL_TFC0, UL_TFC0

DL_TFC3 ,UL_TFC3

UL_TFC0, UL_TFC1,UL_TFC2,

UL_TFC3,

UL_TFC5

RB5: 632

RB5: 632

NOTE 1: UL_TFC0, UL_TFC1, and UL_TFC3 are part of minimum set of TFCIs.

NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs.

For RB5: Test data size has been set to the payload size of the DL TF under test minus 8 bits (size of 7 bit length indicator and expansion bit). The UL RLC SDU size has been set equal to the size of the payload size of the UL TF under test minus 8 bits (the size of 7 bit length indicator and expansion bit).

See 18.3.1.1 for test procedure.

18.3.2.23d.1.4 Test requirements

See 18.3.1.1 for definition of step 10 and step 15.

1. At step 10 the UE shall send a RADIO BEARER SETUP COMPLETE message.

2. At step 15 the UE transmitted transport format shall be

– for sub-test 1: RB5/TF1 (1×336).

– for sub-test 2: RB5/TF2 (2×336).

3. At step 15 the UE shall return

– for sub-test 1 to 2: an RLC SDU on RB5 having the same content as the DL RLC SDU sent by the SS.

18.3.2.23d.2 Interactive or background / UL:32 DL:32 kbps / PS RAB (20 ms TTI) + UL:3.4 DL:3.4 kbps SRBs for DCCH / Payload size 128.

18.3.2.23d.2.1 Conformance requirement

See clause 18.3.2.4.1.

18.3.2.23d.2.2 Test purpose

Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.11.6.4.1.23d, for the uplink payload size 128 case.

18.3.2.23d.2.3 Method of test

Uplink TFS:

TFI

RB5

(16 kbps)

DCCH

TFS

TF0, bits

0x144

0x148

TF1, bits

1×144

1×148

TF2, bits

5×144

N/A

Uplink TFCS:

TFCI

(RB5, DCCH)

UL_TFC0

(TF0, TF0)

UL_TFC1

(TF1, TF0)

UL_TFC2

(TF2, TF0)

UL_TFC3

(TF0, TF1)

UL_TFC4

(TF1, TF1)

UL_TFC5

(TF2, TF1)

Downlink TFS:

TFI

RB5

(32 kbps)

DCCH

TFS

TF0, bits

0x336

0x148

TF1, bits

1×336

1×148

TF2, bits

2×336

N/A

Downlink TFCS:

TFCI

(RB5, DCCH)

DL_TFC0

(TF0, TF0)

DL_TFC1

(TF1, TF0)

DL_TFC2

(TF2, TF0)

DL_TFC3

(TF0, TF1)

DL_TFC4

(TF1, TF1)

DL_TFC5

(TF2, TF1)

Sub-tests:

Sub-test

Downlink TFCS

Under test

Uplink TFCS

Under test

Implicitly tested

Restricted UL TFCIs

(note 1)

UL RLC SDU size

(bits)

(note 2)

Test data size

(bits)

(note 2)

1

DL_TFC1

UL_TFC1

DL_TFC0, UL_TFC0

DL_TFC3,UL_TFC3

UL_TFC0, UL_TFC1,

UL_TFC3,

UL_TFC4

RB5: 376

RB5: 312

2

DL_TFC2

UL_TFC2

DL_TFC0, UL_TFC0

DL_TFC3 ,UL_TFC3

UL_TFC0, UL_TFC1,

UL_TFC2,

UL_TFC3,

UL_TFC5

RB5: 632

RB5: 632

NOTE 1: UL_TFC0, UL_TFC1 and UL_TFC3 are part of minimum set of TFCIs.

NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs.
RB5: Test data size has been set to the payload size of the DL TF under test minus 8 bits (size of 7 bit length indicator and expansion bit). The UL RLC SDU size has been set equal to the size of the payload size of the UL TF under test minus 8 bits (the size of 7 bit length indicator and expansion bit).

See 18.3.1.1 for test procedure.

18.3.2.23d.2.4 Test requirements

See 18.3.1.1 for definition of step 10 and step 15.

1. At step 10 the UE shall send a RADIO BEARER SETUP COMPLETE message.

2. At step 15 the UE transmitted transport format shall be

– for sub-test 1: RB5/TF1 (1×144).

– for sub-test 2: RB5/TF2 (5×144).

3. At step 15 the UE shall return

– for sub-test 1: an RLC SDU on RB5 having the same content as 1 times plus 64 lsb’s of the DL RLC SDU sent by the SS.

– for sub-test 2: an RLC SDU on RB5 having the same content as sent by the SS.

18.3.2.24 Void

18.3.2.25 Interactive or background / UL:32 DL: 64 kbps / PS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH

18.3.2.25.1 Interactive or background / UL:32 DL: 64 kbps / PS RAB+ UL:3.4 DL:3.4 kbps SRBs for DCCH / (PS RAB payload size 320)

18.3.2.25.1.1 Conformance requirement

See 18.3.2.4.1.

18.3.2.25.1.2 Test purpose

Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.11.6.4.1.25 for the uplink payload size of 320 case.

18.3.2.25.1.3 Method of test

Uplink TFS:

TFI

RB5

(32 kbps)

DCCH

TFS

TF0, bits

0x336

0x148

TF1, bits

1×336

1×148

TF2, bits

2×336

N/A

Uplink TFCS:

TFCI

(RB5, DCCH)

UL_TFC0

(TF0, TF0)

UL_TFC1

(TF1, TF0)

UL_TFC2

(TF2, TF0)

UL_TFC3

(TF0, TF1)

UL_TFC4

(TF1, TF1)

UL_TFC5

(TF2, TF1)

Downlink TFS:

TFI

RB5

(64 kbps)

DCCH

TFS

TF0, bits

0x336

0x148

TF1, bits

1×336

1×148

TF2, bits

2×336

N/A

TF3, bits

3×336

N/A

TF4, bits

4×336

N/A

Downlink TFCS:

TFCI

(RB5, DCCH)

DL_TFC0

(TF0, TF0)

DL_TFC1

(TF1, TF0)

DL_TFC2

(TF2, TF0)

DL_TFC3

(TF3, TF0)

DL_TFC4

(TF4, TF0)

DL_TFC5

(TF0, TF1)

DL_TFC6

(TF1, TF1)

DL_TFC7

(TF2, TF1)

DL_TFC8

(TF3, TF1)

DL_TFC9

(TF4, TF1)

Sub-tests:

Sub-test

Downlink TFCS

Under test

Uplink TFCS

Under test

Implicitly tested

Restricted UL TFCIs

(note 1)

UL RLC SDU size

(bits)

(note 2)

Test data size

(bits)

(note 2)

1

DL_TFC1

UL_TFC1

DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC3

UL_TFC0, UL_TFC1,

UL_TFC2,

UL_TFC3

RB5: 312

RB5: 312

2

DL_TFC2

UL_TFC2

DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC3

UL_TFC0, UL_TFC1,

UL_TFC2,

UL_TFC3,

UL_TFC5

RB5: 632

RB5: 632

3

DL_TFC3

UL_TFC1

DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC3

UL_TFC0, UL_TFC1,

UL_TFC2,

UL_TFC3

RB5: 952

RB5: 952

4

DL_TFC4

UL_TFC2

DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC3

UL_TFC0, UL_TFC1,

UL_TFC2,

UL_TFC3,

UL_TFC5

RB5: 1272

RB5: 1272

NOTE 1: UL_TFC0, UL_TFC1, and UL_TFC3 are part of minimum set of TFCIs.

NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs.

See 18.3.1.1 for test procedure.

18.3.2.25.1.4 Test requirements

See 18.3.1.1 for definition of step 10 and step 15.

1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.

2. At step 15 the UE transmitted transport format shall be

– for sub-test 1 and 3: RB5/TF1 (1×336).

– for sub-test 2 and 4: RB5/TF1 (2×336).

3. At step 15 the UE shall return

– for sub-test 1 to 4: an RLC SDU on RB5 having the same content as the DL RLC SDU sent by the SS.

18.3.2.25.2 Interactive or background / UL:32 DL: 64 kbps / PS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH / (PS RAB payload 128)

18.3.2.25.2.1 Conformance requirement

See 18.3.2.4.1.

18.3.2.25.2.2 Test purpose

Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.11.6.4.1.25 for the uplink payload 128 case.

18.3.2.25.2.3 Method of test

Uplink TFS:

TFI

RB5

(32 kbps)

DCCH

TFS

TF0, bits

0x144

0x148

TF1, bits

1×144

1×148

TF2, bits

5×144

N/A

Uplink TFCS:

TFCI

(RB5, DCCH)

UL_TFC0

(TF0, TF0)

UL_TFC1

(TF1, TF0)

UL_TFC2

(TF2, TF0)

UL_TFC3

(TF0, TF1)

UL_TFC4

(TF1, TF1)

UL_TFC5

(TF2, TF1)

Downlink TFS:

TFI

RB5

(64 kbps)

DCCH

TFS

TF0, bits

0x336

0x148

TF1, bits

1×336

1×148

TF2, bits

2×336

N/A

TF3, bits

3×336

N/A

TF4, bits

4×336

N/A

Downlink TFCS:

TFCI

(RB5, DCCH)

DL_TFC0

(TF0, TF0)

DL_TFC1

(TF1, TF0)

DL_TFC2

(TF2, TF0)

DL_TFC3

(TF3, TF0)

DL_TFC4

(TF4, TF0)

DL_TFC5

(TF0, TF1)

DL_TFC6

(TF1, TF1)

DL_TFC7

(TF2, TF1)

DL_TFC8

(TF3, TF1)

DL_TFC9

(TF4, TF1)

Sub-tests:

Sub-test

Downlink TFCS

Under test

Uplink TFCS

Under test

Implicitly tested

Restricted UL TFCIs

(note 1)

UL RLC SDU size

(bits)

(note 2)

Test data size

(bits)

(note 2)

1

DL_TFC1

UL_TFC1

DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC3

UL_TFC0, UL_TFC1,

UL_TFC3,

UL_TFC4

RB5: 376

RB5: 312

2

DL_TFC2

UL_TFC2

DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC3

UL_TFC0, UL_TFC1, UL_TFC2,

UL_TFC3,

UL_TFC5

RB5: 632

RB5: 632

3

DL_TFC3

UL_TFC1

DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC3

UL_TFC0, UL_TFC1,

UL_TFC3,

UL_TFC4

RB5: 1016

RB5: 952

4

DL_TFC4

UL_TFC2

DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC3

UL_TFC0, UL_TFC1, UL_TFC2,

UL_TFC3,

UL_TFC5

RB5: 1272

RB5: 1272

NOTE 1: UL_TFC0, UL_TFC1, and UL_TFC3 are part of minimum set of TFCIs.

NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs.

See 18.3.1.1 for test procedure.

18.3.2.25.2.4 Test requirements

See 18.3.1.1 for definition of step 10 and step 15.

1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.

2. At step 15 the UE transmitted transport format shall be

– for sub-test 1: RB5/TF1 (1×144).

– for sub-test 2: RB5/TF2 (5×144).

– for sub-test 3: RB5/TF1 (1×144).

– for sub-test 4: RB5/TF2 (5×144).

3. At step 15 the UE shall return

– for sub-test 1: an RLC SDU on RB5 having the same content as 1 times plus 64 lsb’s of the DL RLC SDU sent by the SS.

– for sub-test 2: an RLC SDU on RB5 having the same content as the DL RLC SDU sent by the SS.

– for sub-test 3: an RLC SDU on RB5 having the same content as 1 times plus 64 lsb’s of the DL RLC SDU sent by the SS.

– for sub-test 4: an RLC SDU on RB5 having the same content as the DL RLC SDU sent by the SS.

18.3.2.26 Interactive or background / UL:64 DL: 64 kbps / PS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH

18.3.2.26.1 Interactive or background / UL:64 DL: 64 kbps / PS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH / Payload 320, Physical Configuration 1

18.3.2.26.1.1 Conformance requirement

See 18.3.2.4.1.

18.3.2.26.1.2 Test purpose

Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.11.6.4.1.26 for the uplink payload 320 case with physical configuration 1.

18.3.2.26.1.3 Method of test

Uplink TFS:

TFI

RB5

(64 kbps)

DCCH

TFS

TF0, bits

0x336

0x148

TF1, bits

1×336

1×148

TF2, bits

2×336

N/A

TF3, bits

3×336

N/A

TF4, bits

4×336

N/A

Uplink TFCS:

TFCI

(RB5, DCCH)

UL_TFC0

(TF0, TF0)

UL_TFC1

(TF1, TF0)

UL_TFC2

(TF2, TF0)

UL_TFC3

(TF3, TF0)

UL_TFC4

(TF4, TF0)

UL_TFC5

(TF0, TF1)

UL_TFC6

(TF1, TF1)

UL_TFC7

(TF2, TF1)

UL_TFC8

(TF3, TF1)

UL_TFC9

(TF4, TF1)

Physical channel parameters

DPCH Uplink

Physical Configuration 1

Midamble

512 chips

Codes and time slots

SF16 x 1 code x 1 time slot + SF4 x 1 code x 1 time slot

Max. Number of data bits/radio frame

1148 bits

TFCI code word

16 bits

TPC

2 bits

Puncturing Limit

0.48 (alt. 0.44)

Downlink TFS:

TFI

RB5

(64 kbps)

DCCH

TFS

TF0, bits

0x336

0x148

TF1, bits

1×336

1×148

TF2, bits

2×336

N/A

TF3, bits

3×336

N/A

TF4, bits

4×336

N/A

Downlink TFCS:

TFCI

(RB5, DCCH)

DL_TFC0

(TF0, TF0)

DL_TFC1

(TF1, TF0)

DL_TFC2

(TF2, TF0)

DL_TFC3

(TF3, TF0)

DL_TFC4

(TF4, TF0)

DL_TFC5

(TF0, TF1)

DL_TFC6

(TF1, TF1)

DL_TFC7

(TF2, TF1)

DL_TFC8

(TF3, TF1)

DL_TFC9

(TF4, TF1)

Sub-tests:

Sub-test

Downlink TFCS

Under test

Uplink TFCS

Under test

Implicitly tested

Restricted UL TFCIs

(note 1)

UL RLC SDU size

(bits)

(note 2)

Test data size

(bits)

(note 2)

1

DL_TFC1

UL_TFC1

DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,

UL_TFC5,

UL_TFC6

RB5: 312

RB5: 312

2

DL_TFC2

UL_TFC2

DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,

UL_TFC2,

UL_TFC5,

UL_TFC7

RB5: 632

RB5: 632

3

DL_TFC3

UL_TFC3

DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,

UL_TFC3,

UL_TFC5,

UL_TFC8

RB5: 952

RB5: 952

4

DL_TFC4

UL_TFC4

DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,

UL_TFC4,

UL_TFC5,

UL_TFC9

RB5: 1272

RB5: 1272

NOTE 1: UL_TFC0, UL_TFC1 and UL_TFC5 are part of minimum set of TFCIs.

NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs.
RB5: Test data size has been set to the payload size of the DL TF under test minus 8 bits (size of 7 bit length indicator and expansion bit). The UL RLC SDU size parameter has been set to achieve verification of all test data sent by SS in downlink, i.e. UL RLC SDU size is set to nearest multiple of the payload size of the UL TF under test minus 8 bits (size of 7 bit length indicator and expansion bit) which is equal or bigger than the test data size.

See 18.3.1.1 for test procedure.

18.3.2.26.1.4 Test requirements

See 18.3.1.1 for definition of step 10 and step 15.

1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.

2. At step 15 the UE transmitted transport format shall be

– for sub-test 1: RB5/TF1 (1×336).

– for sub-test 2: RB5/TF2 (2×336) or RB5/TF1 (1×336).

– for sub-test 3: RB5/TF3 (3×336) or RB5/TF1 (1×336).

– for sub-test 4: RB5/TF4 (4×336) or RB5/TF1 (1×336).

3. At step 15 the UE shall return

– for sub-test 1 to 4: an RLC SDU on RB5 having the same content as the DL RLC SDU sent by the SS.

18.3.2.26.2 Interactive or background / UL:64 DL: 64 kbps / PS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH / Payload 128, Physical Configuration 2

18.3.2.26.2.1 Conformance requirement

See 18.3.2.4.1.

18.3.2.26.2.2 Test purpose

Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.11.6.4.1.26 for the uplink payload 128 case with physical configuration 2.

18.3.2.26.2.3 Method of test

Uplink TFS:

TFI

RB5

(64 kbps)

DCCH

TFS

TF0, bits

0x144

0x148

TF1, bits

1×144

1×148

TF2, bits

3×144

N/A

TF3, bits

7×144

N/A

TF4, bits

10×144

N/A

Uplink TFCS:

TFCI

(RB5, DCCH)

UL_TFC0

(TF0, TF0)

UL_TFC1

(TF1, TF0)

UL_TFC2

(TF2, TF0)

UL_TFC3

(TF3, TF0)

UL_TFC4

(TF4, TF0)

UL_TFC5

(TF0, TF1)

UL_TFC6

(TF1, TF1)

UL_TFC7

(TF2, TF1)

UL_TFC8

(TF3, TF1)

UL_TFC9

(TF4, TF1)

Physical channel parameters

DPCH Uplink

Physical Configuration 2

Midamble

512 chips

Codes and time slots

SF2 x 1 code x 1 time slot + SF4 x 1 code x 1 time slot

Max. Number of data bits/radio frame

2784 bits

TFCI code word

16 bits

TPC

2 bits

Puncturing Limit

1

Downlink TFS:

TFI

RB5

(64 kbps)

DCCH

TFS

TF0, bits

0x336

0x148

TF1, bits

1×336

1×148

TF2, bits

2×336

N/A

TF3, bits

3×336

N/A

TF4, bits

4×336

N/A

Downlink TFCS:

TFCI

(RB5, DCCH)

DL_TFC0

(TF0, TF0)

DL_TFC1

(TF1, TF0)

DL_TFC2

(TF2, TF0)

DL_TFC3

(TF3, TF0)

DL_TFC4

(TF4, TF0)

DL_TFC5

(TF0, TF1)

DL_TFC6

(TF1, TF1)

DL_TFC7

(TF2, TF1)

DL_TFC8

(TF3, TF1)

DL_TFC9

(TF4, TF1)

Sub-tests:

Sub-test

Downlink TFCS

Under test

Uplink TFCS

Under test

Implicitly tested

Restricted UL TFCIs

(note 1)

UL RLC SDU size

(bits)

(note 2)

Test data size

(bits)

(note 2)

1

DL_TFC1

UL_TFC1

DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,

UL_TFC5,

UL_TFC6

RB5: 376

RB5: 312

2

DL_TFC2

UL_TFC2

DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,

UL_TFC2,

UL_TFC5,

UL_TFC7

RB5: 760

RB5: 632

3

DL_TFC3

UL_TFC3

DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,

UL_TFC3,

UL_TFC5,

UL_TFC8

RB5: 1784

RB5: 952

4

DL_TFC4

UL_TFC4

DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,

UL_TFC4,

UL_TFC5,

UL_TFC9

RB5: 1272

RB5: 1272

NOTE 1: UL_TFC0, UL_TFC1 and UL_TFC5 are part of minimum set of TFCIs.

NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs.
RB5: Test data size has been set to the payload size of the DL TF under test minus 8 bits (size of 7 bit length indicator and expansion bit). The UL RLC SDU size parameter has been set to achieve verification of all test data sent by SS in downlink, i.e. UL RLC SDU size is set to nearest multiple of the payload size of the UL TF under test minus 8 bits (size of 7 bit length indicator and expansion bit) which is equal or bigger than the test data size.

See 18.3.1.1 for test procedure.

18.3.2.26.2.4 Test requirements

See 18.3.1.1 for definition of step 10 and step 15.

1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.

2. At step 15 the UE transmitted transport format shall be

– for sub-test 1: RB5/TF1 (1×144).

– for sub-test 2: RB5/TF2 (3×144).

– for sub-test 3: RB5/TF3 (7×144).

– for sub-test 4: RB5/TF4 (10×144).

3. At step 15 the UE shall return

– for sub-test 1: an RLC SDU on RB5 having the same content as 1 times plus 64 lsb’s of the DL RLC SDU sent by the SS.

– for sub-test 2: an RLC SDU on RB5 having the same content as 1 times plus 128 lsb’s of the DL RLC SDU sent by the SS.

– for sub-test 3: an RLC SDU on RB5 having the same content as 1 times plus 832 lsb’s of the DL RLC SDU sent by the SS.

– for sub-test 4: an RLC SDU on RB5 having the same content as the DL RLC SDU sent by the SS.

18.3.2.27 Interactive or background / UL:64 DL:128 kbps / PS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH

18.3.2.27.1 Interactive or background / UL:64 DL:128 kbps / PS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH / Payload 320, Physical Configuration 1

18.3.2.27.1.1 Conformance requirement

See 18.3.2.4.1.

18.3.2.27.1.2 Test purpose

Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.11.6.4.1.27 for the uplink payload 320 case with physical configuration 1.

18.3.2.27.1.3 Method of test

Uplink TFS:

TFI

RB5

(64 kbps)

DCCH

TFS

TF0, bits

0x336

0x148

TF1, bits

1×336

1×148

TF2, bits

2×336

N/A

TF3, bits

3×336

N/A

TF4, bits

4×336

N/A

Uplink TFCS:

TFCI

(RB5, DCCH)

UL_TFC0

(TF0, TF0)

UL_TFC1

(TF1, TF0)

UL_TFC2

(TF2, TF0)

UL_TFC3

(TF3, TF0)

UL_TFC4

(TF4, TF0)

UL_TFC5

(TF0, TF1)

UL_TFC6

(TF1, TF1)

UL_TFC7

(TF2, TF1)

UL_TFC8

(TF3, TF1)

UL_TFC9

(TF4, TF1)

Physical channel parameters

DPCH Uplink

Physical Configuration 1

Midamble

512 chips

Codes and time slots

SF16 x 1 code x 1 time slot + SF4 x 1 code x 1 time slot

Max. Number of data bits/radio frame

1148 bits

TFCI code word

16 bits

TPC

2 bits

Puncturing Limit

0.48 (alt. 0.44)

Downlink TFS:

TFI

RB5

(128 kbps)

DCCH

TFS

TF0, bits

0x336

0x148

TF1, bits

1×336

1×148

TF2, bits

2×336

N/A

TF3, bits

4×336

N/A

TF4, bits

8×336

N/A

Downlink TFCS:

TFCI

(RB5, DCCH)

DL_TFC0

(TF0, TF0)

DL_TFC1

(TF1, TF0)

DL_TFC2

(TF2, TF0)

DL_TFC3

(TF3, TF0)

DL_TFC4

(TF4, TF0)

DL_TFC5

(TF0, TF1)

DL_TFC6

(TF1, TF1)

DL_TFC7

(TF2, TF1)

DL_TFC8

(TF3, TF1)

DL_TFC9

(TF4, TF1)

Physical channel parameters

DPCH Downlink

Physical Configuration 1

Midamble

256 chips

Codes and time slots

SF16 x 8 codes x 1 time slot

Max. Number of data bits/radio frame

2192 bits

TFCI code word

16 bits

Puncturing limit

0.48

Sub-tests:

Sub-test

Downlink TFCS

Under test

Uplink TFCS

Under test

Implicitly tested

Restricted UL TFCIs

(note 1)

UL RLC SDU size

(bits)

(note 2)

Test data size

(bits)

(note 2)

1

DL_TFC1

UL_TFC1

DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,

UL_TFC5,

UL_TFC6

RB5: 312

RB5: 312

2

DL_TFC2

UL_TFC2

DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,

UL_TFC2,

UL_TFC5,

UL_TFC7

RB5: 632

RB5: 632

3

DL_TFC3

UL_TFC3

DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,

UL_TFC3,

UL_TFC5,

UL_TFC8

RB5: 1912

RB5: 1272

4

DL_TFC4

UL_TFC4

DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,

UL_TFC4,

UL_TFC5,

UL_TFC9

RB5: 2552

RB5: 2552

NOTE 1: UL_TFC0, UL_TFC1, and UL_TFC5 are part of minimum set of TFCIs.

NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs.
RB5: Test data size has been set to the payload size of the DL TF under test minus 8 bits (size of 7 bit length indicator and expansion bit). The UL RLC SDU size parameter has been set to achieve verification of all test data sent by SS in downlink, i.e. UL RLC SDU size is set to nearest multiple of the payload size of the UL TF under test minus 8 bits (size of 7 bit length indicator and expansion bit) which is equal or bigger than the test data size.

See 18.3.1.1 for test procedure.

18.3.2.27.1.4 Test requirements

See 18.3.1.1 for definition of step 10 and step 15.

1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.

2. At step 15 the UE transmitted transport format shall be

– for sub-test 1: RB5/TF1 (1×336).

– for sub-test 2: RB5/TF2 (2×336) or RB5/TF1 (1×336).

– for sub-test 3: RB5/TF3 (3×336) or RB5/TF1 (1×336).

– for sub-test 4: RB5/TF4 (4×336) or RB5/TF1 (1×336).

3. At step 15 the UE shall return

– for sub-test 1, 2 and 4: an RLC SDU on RB5 having the same content as the DL RLC SDU sent by the SS.

– for sub-test 3: an RLC SDU on RB5 having the same content as 1 times plus 640 lsb’s of the DL RLC SDU sent by the SS.

18.3.2.27.2 Interactive or background / UL:64 DL:128 kbps / PS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH / Payload 128, Physical Configuration 2

18.3.2.27.2.1 Conformance requirement

See 18.3.2.4.1.

18.3.2.27.2.2 Test purpose

Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.11.6.4.1.27 for the uplink payload 128 case with physical configuration 2.

18.3.2.27.2.3 Method of test

Uplink TFS:

TFI

RB5

(64 kbps)

DCCH

TFS

TF0, bits

0x144

0x148

TF1, bits

1×144

1×148

TF2, bits

3×144

N/A

TF3, bits

7×144

N/A

TF4, bits

10×144

N/A

Uplink TFCS:

TFCI

(RB5, DCCH)

UL_TFC0

(TF0, TF0)

UL_TFC1

(TF1, TF0)

UL_TFC2

(TF2, TF0)

UL_TFC3

(TF3, TF0)

UL_TFC4

(TF4, TF0)

UL_TFC5

(TF0, TF1)

UL_TFC6

(TF1, TF1)

UL_TFC7

(TF2, TF1)

UL_TFC8

(TF3, TF1)

UL_TFC9

(TF4, TF1)

Physical channel parameters

DPCH Uplink

Physical Configuration 2

Midamble

512 chips

Codes and time slots

SF2 x 1 code x 1 time slot + SF4 x 1 code x 1 time slot

Max. Number of data bits/radio frame

2784 bits

TFCI code word

16 bits

TPC

2 bits

Puncturing Limit

1

Downlink TFS:

TFI

RB5

(128 kbps)

DCCH

TFS

TF0, bits

0x336

0x148

TF1, bits

1×336

1×148

TF2, bits

2×336

N/A

TF3, bits

4×336

N/A

TF4, bits

8×336

N/A

Downlink TFCS:

TFCI

(RB5, DCCH)

DL_TFC0

(TF0, TF0)

DL_TFC1

(TF1, TF0)

DL_TFC2

(TF2, TF0)

DL_TFC3

(TF3, TF0)

DL_TFC4

(TF4, TF0)

DL_TFC5

(TF0, TF1)

DL_TFC6

(TF1, TF1)

DL_TFC7

(TF2, TF1)

DL_TFC8

(TF3, TF1)

DL_TFC9

(TF4, TF1)

Physical channel parameters

DPCH Downlink

Physical Configuration 2

Midamble

256 chips

Codes and time slots

SF16 x 4 codes x 2 time slots + SF16 x 3 codes x 2 time slots

Max. Number of data bits/radio frame

3848 bits

TFCI code word

16 bits

Puncturing limit

0.84

Sub-tests:

Sub-test

Downlink TFCS

Under test

Uplink TFCS

Under test

Implicitly tested

Restricted UL TFCIs

(note 1)

UL RLC SDU size

(bits)

(note 2)

Test data size

(bits)

(note 2)

1

DL_TFC1

UL_TFC1

DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,

UL_TFC5,

UL_TFC6

RB5: 376

RB5: 312

2

DL_TFC2

UL_TFC2

DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,

UL_TFC2,

UL_TFC5,

UL_TFC7

RB5: 760

RB5: 632

3

DL_TFC3

UL_TFC3

DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,

UL_TFC3,

UL_TFC5,

UL_TFC8

RB5: 1784

RB5: 1272

4

DL_TFC4

UL_TFC4

DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,

UL_TFC4,

UL_TFC5,

UL_TFC9

RB5: 2552

RB5: 2552

NOTE 1: UL_TFC0, UL_TFC1, and UL_TFC5 are part of minimum set of TFCIs.

NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs.
RB5: Test data size has been set to the payload size of the DL TF under test minus 8 bits (size of 7 bit length indicator and expansion bit). The UL RLC SDU size parameter has been set to achieve verification of all test data sent by SS in downlink, i.e. UL RLC SDU size is set to nearest multiple of the payload size of the UL TF under test minus 8 bits (size of 7 bit length indicator and expansion bit) which is equal or bigger than the test data size.

See 18.3.1.1 for test procedure.

18.3.2.27.2.4 Test requirements

See 18.3.1.1 for definition of step 10 and step 15.

1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.

2. At step 15 the UE transmitted transport format shall be

– for sub-test 1: RB5/TF1 (1×144).

– for sub-test 2: RB5/TF2 (3×144).

– for sub-test 3: RB5/TF3 (7×144).

– for sub-test 4: RB5/TF4 (10×144).

3. At step 15 the UE shall return

– for sub-test 1: an RLC SDU on RB5 having the same content as 1 times plus 64 lsb’s of the DL RLC SDU sent by the SS.

– for sub-test 2: an RLC SDU on RB5 having the same content as 1 times plus 128 lsb’s of the DL RLC SDU sent by the SS.

– for sub-test 3: an RLC SDU on RB5 having the same content as 1 times plus 512 lsb’s of the DL RLC SDU sent by the SS.

– for sub-test 4: an RLC SDU on RB5 having the same content as the DL RLC SDU sent by the SS.

18.3.2.28 Interactive or background / UL:128 DL:128 kbps / PS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH

18.3.2.28.1 Interactive or background / UL:128 DL:128 kbps / PS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH / Payload 320, Physical Configuration 1

18.3.2.28.1.1 Conformance requirement

See 18.3.2.4.1.

18.3.2.28.1.2 Test purpose

Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.11.6.4.1.28 for the uplink payload 320 case with physical configuration 1.

18.3.2.28.1.3 Method of test

Uplink TFS:

TFI

RB5

(128 kbps)

DCCH

TFS

TF0, bits

0x336

0x148

TF1, bits

1×336

1×148

TF2, bits

2×336

N/A

TF3, bits

4×336

N/A

TF4, bits

8×336

N/A

Uplink TFCS:

TFCI

(RB5, DCCH)

UL_TFC0

(TF0, TF0)

UL_TFC1

(TF1, TF0)

UL_TFC2

(TF2, TF0)

UL_TFC3

(TF3, TF0)

UL_TFC4

(TF4, TF0)

UL_TFC5

(TF0, TF1)

UL_TFC6

(TF1, TF1)

UL_TFC7

(TF2, TF1)

UL_TFC8

(TF3, TF1)

UL_TFC9

(TF4, TF1)

Physical channel parameters

DPCH Uplink

Physical Configuration 1

Midamble

256 chips

Codes and time slots

SF2 x 1 code x 1 timeslot

Max. Number of data bits/radio frame

2064 bits

TFCI code word

16 bits

TPC

2 bits

Puncturing Limit

0.44 (alt. 0.40)

Downlink TFS:

TFI

RB5

(128 kbps)

DCCH

TFS

TF0, bits

0x336

0x148

TF1, bits

1×336

1×148

TF2, bits

2×336

N/A

TF3, bits

4×336

N/A

TF4, bits

8×336

N/A

Downlink TFCS:

TFCI

(RB5, DCCH)

DL_TFC0

(TF0, TF0)

DL_TFC1

(TF1, TF0)

DL_TFC2

(TF2, TF0)

DL_TFC3

(TF3, TF0)

DL_TFC4

(TF4, TF0)

DL_TFC5

(TF0, TF1)

DL_TFC6

(TF1, TF1)

DL_TFC7

(TF2, TF1)

DL_TFC8

(TF3, TF1)

DL_TFC9

(TF4, TF1)

Physical channel parameters

DPCH Downlink

Physical Configuration 1

Midamble

256 chips

Codes and time slots

SF16 x 8 codes x 1 time slot

Max. Number of data bits/radio frame

2192 bits

TFCI code word

16 bits

Puncturing limit

0.48

Sub-tests:

Sub-test

Downlink TFCS

Under test

Uplink TFCS

Under test

Implicitly tested

Restricted UL TFCIs

(note 1)

UL RLC SDU size

(bits)

(note 2)

Test data size

(bits)

(note 2)

1

DL_TFC1

UL_TFC1

DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,

UL_TFC5,

UL_TFC6

RB5: 312

RB5: 312

2

DL_TFC2

UL_TFC2

DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1, UL_TFC2,

UL_TFC5,

UL_TFC7

RB5: 632

RB5: 632

3

DL_TFC3

UL_TFC3

DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1, UL_TFC3,

UL_TFC5,

UL_TFC8

RB5: 1272

RB5: 1272

4

DL_TFC4

UL_TFC4

DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1, UL_TFC4,

UL_TFC5,

UL_TFC9

RB5: 2552

RB5: 2552

NOTE 1: UL_TFC0, UL_TFC1, and UL_TFC5 are part of minimum set of TFCIs.

NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs.

See 18.3.1.1 for test procedure.

18.3.2.28.1.4 Test requirements

See 18.3.1.1 for definition of step 10 and step 15.

1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.

2. At step 15 the UE transmitted transport format shall be

– for sub-test 1: RB5/TF1 (1×336).

– for sub-test 2: RB5/TF2 (2×336).

– for sub-test 3: RB5/TF3 (4×336).

– for sub-test 4: RB5/TF4 (8×336).

3. At step 15 the UE shall return

– for sub-test 1 to 4: an RLC SDU on RB5 having the same content as the DL RLC SDU sent by the SS.

18.3.2.28.2 Interactive or background / UL:128 DL:128 kbps / PS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH / Payload 128, Physical Configuration 2

18.3.2.28.2.1 Conformance requirement

See 18.3.2.4.1.

18.3.2.28.2.2 Test purpose

Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.11.6.4.1.28 for the uplink payload 128 case with physical configuration 2.

18.3.2.28.2.3 Method of test

Uplink TFS:

TFI

RB5

(128 kbps)

DCCH

TFS

TF0, bits

0x144

0x148

TF1, bits

1×144

1×148

TF2, bits

7×144

N/A

TF3, bits

14×144

N/A

TF4, bits

20×144

N/A

Uplink TFCS:

TFCI

(RB5, DCCH)

UL_TFC0

(TF0, TF0)

UL_TFC1

(TF1, TF0)

UL_TFC2

(TF2, TF0)

UL_TFC3

(TF3, TF0)

UL_TFC4

(TF4, TF0)

UL_TFC5

(TF0, TF1)

UL_TFC6

(TF1, TF1)

UL_TFC7

(TF2, TF1)

UL_TFC8

(TF3, TF1)

UL_TFC9

(TF4, TF1)

Physical channel parameters

DPCH Uplink

Physical Configuration 2

Midamble

256 chips

Codes and time slots

SF2 x 1 code x 2 timeslots + SF4 x 1 code x 1 time slot

Max. Number of data bits/radio frame

5376 bits

TFCI code word

16 bits

TPC

2 bits

Puncturing Limit

1

Downlink TFS:

TFI

RB5

(128 kbps)

DCCH

TFS

TF0, bits

0x336

0x148

TF1, bits

1×336

1×148

TF2, bits

2×336

N/A

TF3, bits

4×336

N/A

TF4, bits

8×336

N/A

Downlink TFCS:

TFCI

(RB5, DCCH)

DL_TFC0

(TF0, TF0)

DL_TFC1

(TF1, TF0)

DL_TFC2

(TF2, TF0)

DL_TFC3

(TF3, TF0)

DL_TFC4

(TF4, TF0)

DL_TFC5

(TF0, TF1)

DL_TFC6

(TF1, TF1)

DL_TFC7

(TF2, TF1)

DL_TFC8

(TF3, TF1)

DL_TFC9

(TF4, TF1)

Physical channel parameters

DPCH Downlink

Physical Configuration 2

Midamble

256 chips

Codes and time slots

SF16 x 4 codes x 2 time slots + SF16 x 3 codes x 2 time slots

Max. Number of data bits/radio frame

3848 bits

TFCI code word

16 bits

Puncturing limit

0.84

Sub-tests:

Sub-test

Downlink TFCS

Under test

Uplink TFCS

Under test

Implicitly tested

Restricted UL TFCIs

(note 1)

UL RLC SDU size

(bits)

(note 2)

Test data size

(bits)

(note 2)

1

DL_TFC1

UL_TFC1

DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,

UL_TFC5,

UL_TFC6

RB5: 376

RB5: 312

2

DL_TFC2

UL_TFC2

DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1, UL_TFC2,

UL_TFC5,

UL_TFC7

RB5: 888

RB5: 632

3

DL_TFC3

UL_TFC3

DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1, UL_TFC3,

UL_TFC5,

UL_TFC8

RB5: 1784

RB5: 1272

4

DL_TFC4

UL_TFC4

DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1, UL_TFC4,

UL_TFC5,

UL_TFC9

RB5: 2552

RB5: 2552

NOTE 1: UL_TFC0, UL_TFC1, and UL_TFC5 are part of minimum set of TFCIs.

NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs.

See 18.3.1.1 for test procedure.

18.3.2.28.2.4 Test requirements

See 18.3.1.1 for definition of step 10 and step 15.

1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.

2. At step 15 the UE transmitted transport format shall be

– for sub-test 1: RB5/TF1 (1×144).

– for sub-test 2: RB5/TF2 (7×144).

– for sub-test 3: RB5/TF3 (14×144).

– for sub-test 4: RB5/TF4 (20×144).

3. At step 15 the UE shall return

– for sub-test 1: an RLC SDU on RB5 having the same content as 1 times plus 64 lsb’s of the DL RLC SDU sent by the SS.

– for sub-test 2: an RLC SDU on RB5 having the same content as 1 times plus 256 lsb’s of the DL RLC SDU sent by the SS.

– for sub-test 3: an RLC SDU on RB5 having the same content as 1 times plus 512 lsb’s of the DL RLC SDU sent by the SS.

– for sub-test 4: an RLC SDU on RB5 having the same content as the DL RLC SDU sent by the SS.

18.3.2.29 Interactive or background / UL:64 DL:144 kbps / PS RAB + UL:3.4 DL: 3.4 kbps SRBs for DCCH

18.3.2.29.1 Interactive or background / UL:64 DL:144 kbps / PS RAB + UL:3.4 DL: 3.4 kbps SRBs for DCCH / Payload 320, Physical Configuration 1

18.3.2.29.1.1 Conformance requirement

See 18.3.2.4.1.

18.3.2.29.1.2 Test purpose

Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.11.6.4.1.29 for the uplink payload 320 case with physical configuration 1.

18.3.2.29.1.3 Method of test

Uplink TFS:

TFI

RB5

(64 kbps)

DCCH

TFS

TF0, bits

0x336

0x148

TF1, bits

1×336

1×148

TF2, bits

2×336

N/A

TF3, bits

3×336

N/A

TF4, bits

4×336

N/A

Uplink TFCS:

TFCI

(RB5, DCCH)

UL_TFC0

(TF0, TF0)

UL_TFC1

(TF1, TF0)

UL_TFC2

(TF2, TF0)

UL_TFC3

(TF3, TF0)

UL_TFC4

(TF4, TF0)

UL_TFC5

(TF0, TF1)

UL_TFC6

(TF1, TF1)

UL_TFC7

(TF2, TF1)

UL_TFC8

(TF3, TF1)

UL_TFC9

(TF4, TF1)

Physical channel parameters

DPCH Uplink

Physical Configuration 1

Midamble

512 chips

Codes and time slots

SF16 x 1 code x 1 time slot + SF4 x 1 code x 1 time slot

Max. Number of data bits/radio frame

1148 bits

TFCI code word

16 bits

TPC

2 bits

Puncturing Limit

0.48 (alt. 0.44)

Downlink TFS:

TFI

RB5

(144 kbps)

DCCH

TFS

TF0, bits

0x336

0x148

TF1, bits

1×336

1×148

TF2, bits

2×336

N/A

TF3, bits

4×336

N/A

TF4, bits

8×336

N/A

TF5, bits

9×336

N/A

Downlink TFCS:

TFCI

(RB5, DCCH)

DL_TFC0

(TF0, TF0)

DL_TFC1

(TF1, TF0)

DL_TFC2

(TF2, TF0)

DL_TFC3

(TF3, TF0)

DL_TFC4

(TF4, TF0)

DL_TFC5

(TF5, TF0)

DL_TFC6

(TF0, TF1)

DL_TFC7

(TF1, TF1)

DL_TFC8

(TF2, TF1)

DL_TFC9

(TF3, TF1)

DL_TFC10

(TF4, TF1)

DL_TFC11

(TF5, TF1)

Sub-tests:

Sub-test

Downlink TFCS

Under test

Uplink TFCS

Under test

Implicitly tested

Restricted UL TFCIs

(note 1)

UL RLC SDU size

(bits)

(note 2)

Test data size

(bits)

(note 2)

1

DL_TFC1

UL_TFC1

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,

UL_TFC5,

UL_TFC6

RB5: 312

RB5: 312

2

DL_TFC2

UL_TFC2

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,

UL_TFC2,

UL_TFC5,

UL_TFC7

RB5: 632

RB5: 632

3

DL_TFC3

UL_TFC3

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,

UL_TFC3,

UL_TFC5,

UL_TFC8

RB5: 1912

RB5: 1272

4

DL_TFC4

UL_TFC4

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,

UL_TFC4,

UL_TFC5,

UL_TFC9

RB5: 2552

RB5: 2552

5

DL_TFC5

UL_TFC3

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,

UL_TFC3,

UL_TFC5,

UL_TFC8

RB5: 2872

RB5: 2872

NOTE 1: UL_TFC0, UL_TFC1 and UL_TFC5 are part of minimum set of TFCIs.

NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs.
RB5: Test data size has been set to the payload size of the DL TF under test minus 8 bits (size of 7 bit length indicator and expansion bit). The UL RLC SDU size parameter has been set to achieve verification of all test data sent by SS in downlink, i.e. UL RLC SDU size is set to nearest multiple of the payload size of the UL TF under test minus 8 bits (size of 7 bit length indicator and expansion bit) which is equal or bigger than the test data size.

See 18.3.1.1 for test procedure.

18.3.2.29.1.4 Test requirements

See 18.3.1.1 for definition of step 10 and step 15.

1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.

2. At step 15 the UE transmitted transport format shall be

– for sub-test 1: RB5/TF1 (1×336).

– for sub-test 2: RB5/TF2 (2×336) or RB5/TF1 (1×336).

– for sub-test 3: RB5/TF3 (3×336) or RB5/TF1 (1×336).

– for sub-test 4: RB5/TF4 (4×336) or RB5/TF1 (1×336).

– for sub-test 5: RB5/TF3 (3×336) or RB5/TF1 (1×336).

3. At step 15 the UE shall return

– for sub-test 1, 2, 4 and 5: an RLC SDU on RB5 having the same content as the DL RLC SDU sent by the SS.

– for sub-test 3: an RLC SDU on RB5 having the same content as 1 times plus 640 lsb’s of the DL RLC SDU sent by the SS.

18.3.2.29.2 Interactive or background / UL:64 DL:144 kbps / PS RAB + UL:3.4 DL: 3.4 kbps SRBs for DCCH / Payload 128, Physical Configuration 2

18.3.2.29.2.1 Conformance requirement

See 18.3.2.4.1.

18.3.2.29.2.2 Test purpose

Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.11.6.4.1.29 for the uplink payload 128 case with physical configuration 2.

18.3.2.29.2.3 Method of test

Uplink TFS:

TFI

RB5

(64 kbps)

DCCH

TFS

TF0, bits

0x144

0x148

TF1, bits

1×144

1×148

TF2, bits

3×144

N/A

TF3, bits

7×144

N/A

TF4, bits

10×144

N/A

Uplink TFCS:

TFCI

(RB5, DCCH)

UL_TFC0

(TF0, TF0)

UL_TFC1

(TF1, TF0)

UL_TFC2

(TF2, TF0)

UL_TFC3

(TF3, TF0)

UL_TFC4

(TF4, TF0)

UL_TFC5

(TF0, TF1)

UL_TFC6

(TF1, TF1)

UL_TFC7

(TF2, TF1)

UL_TFC8

(TF3, TF1)

UL_TFC9

(TF4, TF1)

Physical channel parameters

DPCH Uplink

Physical Configuration 2

Midamble

512 chips

Codes and time slots

SF2 x 1 code x 1 time slot + SF4 x 1 code x 1 time slot

Max. Number of data bits/radio frame

2784 bits

TFCI code word

16 bits

TPC

2 bits

Puncturing Limit

1

Downlink TFS:

TFI

RB5

(144 kbps)

DCCH

TFS

TF0, bits

0x336

0x148

TF1, bits

1×336

1×148

TF2, bits

2×336

N/A

TF3, bits

4×336

N/A

TF4, bits

8×336

N/A

TF5, bits

9×336

N/A

Downlink TFCS:

TFCI

(RB5, DCCH)

DL_TFC0

(TF0, TF0)

DL_TFC1

(TF1, TF0)

DL_TFC2

(TF2, TF0)

DL_TFC3

(TF3, TF0)

DL_TFC4

(TF4, TF0)

DL_TFC5

(TF5, TF0)

DL_TFC6

(TF0, TF1)

DL_TFC7

(TF1, TF1)

DL_TFC8

(TF2, TF1)

DL_TFC9

(TF3, TF1)

DL_TFC10

(TF4, TF1)

DL_TFC11

(TF5, TF1)

Sub-tests:

Sub-test

Downlink TFCS

Under test

Uplink TFCS

Under test

Implicitly tested

Restricted UL TFCIs

(note 1)

UL RLC SDU size

(bits)

(note 2)

Test data size

(bits)

(note 2)

1

DL_TFC1

UL_TFC1

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,

UL_TFC5,

UL_TFC6

RB5: 376

RB5: 312

2

DL_TFC2

UL_TFC2

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,

UL_TFC2,

UL_TFC5,

UL_TFC7

RB5: 760

RB5: 632

3

DL_TFC3

UL_TFC4

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,

UL_TFC4,

UL_TFC5,

UL_TFC9

RB5: 1272

RB5: 1272

4

DL_TFC4

UL_TFC4

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,

UL_TFC4,

UL_TFC5,

UL_TFC9

RB5: 2552

RB5: 2552

5

DL_TFC5

UL_TFC3

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,

UL_TFC3,

UL_TFC5,

UL_TFC8

RB5: 3576

RB5: 2872

NOTE 1: UL_TFC0, UL_TFC1 and UL_TFC5 are part of minimum set of TFCIs.

NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs.
RB5: Test data size has been set to the payload size of the DL TF under test minus 8 bits (size of 7 bit length indicator and expansion bit). The UL RLC SDU size parameter has been set to achieve verification of all test data sent by SS in downlink, i.e. UL RLC SDU size is set to nearest multiple of the payload size of the UL TF under test minus 8 bits (size of 7 bit length indicator and expansion bit) which is equal or bigger than the test data size.

See 18.3.1.1 for test procedure.

18.3.2.29.2.4 Test requirements

See 18.3.1.1 for definition of step 10 and step 15.

1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.

2. At step 15 the UE transmitted transport format shall be

– for sub-test 1: RB5/TF1 (1×144).

– for sub-test 2: RB5/TF2 (3×144).

– for sub-test 3: RB5/TF4 (10×144).

– for sub-test 4: RB5/TF4 (10×144).

– for sub-test 5: RB5/TF3 (7×144).

3. At step 15 the UE shall return

– for sub-test 1: an RLC SDU on RB5 having the same content as 1 times plus 64 lsb’s of the DL RLC SDU sent by the SS.

– for sub-test 2: an RLC SDU on RB5 having the same content as 1 times plus 128 lsb’s of the DL RLC SDU sent by the SS.

– for sub-test 3 and 4: an RLC SDU on RB5 having the same content as the DL RLC SDU sent by the SS.

– for sub-test 5: an RLC SDU on RB5 having the same content as 1 times plus 712 lsb’s of the DL RLC SDU sent by the SS.

18.3.2.30 Interactive or background / UL:144 DL:144 kbps / PS RAB + UL:3.4 DL: 3.4 kbps SRBs for DCCH

18.3.2.30.1 Interactive or background / UL:144 DL:144 kbps / PS RAB + UL:3.4 DL: 3.4 kbps SRBs for DCCH / Payload 320, TTI 20 ms

18.3.2.30.1.1 Conformance requirement

See 18.3.2.4.1.

18.3.2.30.1.2 Test purpose

Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.11.6.4.1.30 for the uplink payload 320, TTI 20 ms case.

18.3.2.30.1.3 Method of test

Uplink TFS:

TFI

RB5

(144 kbps)

DCCH

TFS

TF0, bits

0x336

0x148

TF1, bits

1×336

1×148

TF2, bits

2×336

N/A

TF3, bits

4×336

N/A

TF4, bits

8×336

N/A

TF5, bits

9×336

N/A

Uplink TFCS:

TFCI

(RB5, DCCH)

UL_TFC0

(TF0, TF0)

UL_TFC1

(TF1, TF0)

UL_TFC2

(TF2, TF0)

UL_TFC3

(TF3, TF0)

UL_TFC4

(TF4, TF0)

UL_TFC5

(TF5, TF0)

UL_TFC6

(TF0, TF1)

UL_TFC7

(TF1, TF1)

UL_TFC8

(TF2, TF1)

UL_TFC9

(TF3, TF1)

UL_TFC10

(TF4, TF1)

UL_TFC11

(TF5, TF1)

Downlink TFS:

TFI

RB5

(144 kbps)

DCCH

TFS

TF0, bits

0x336

0x148

TF1, bits

1×336

1×148

TF2, bits

2×336

N/A

TF3, bits

4×336

N/A

TF4, bits

8×336

N/A

TF5, bits

9×336

N/A

Downlink TFCS:

TFCI

(RB5, DCCH)

DL_TFC0

(TF0, TF0)

DL_TFC1

(TF1, TF0)

DL_TFC2

(TF2, TF0)

DL_TFC3

(TF3, TF0)

DL_TFC4

(TF4, TF0)

DL_TFC5

(TF5, TF0)

DL_TFC6

(TF0, TF1)

DL_TFC7

(TF1, TF1)

DL_TFC8

(TF2, TF1)

DL_TFC9

(TF3, TF1)

DL_TFC10

(TF4, TF1)

DL_TFC11

(TF5, TF1)

Sub-tests:

Sub-test

Downlink TFCS

Under test

Uplink TFCS

Under test

Implicitly tested

Restricted UL TFCIs

(note 1)

UL RLC SDU size

(bits)

(note 2)

Test data size

(bits)

(note 2)

1

DL_TFC1

UL_TFC1

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6

UL_TFC0, UL_TFC1,

UL_TFC6,

UL_TFC7

RB5: 312

RB5: 312

2

DL_TFC2

UL_TFC2

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6

UL_TFC0, UL_TFC1,UL_TFC2,

UL_TFC6,

UL_TFC8

RB5: 632

RB5: 632

3

DL_TFC3

UL_TFC3

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6

UL_TFC0, UL_TFC1,UL_TFC3,

UL_TFC6,

UL_TFC9

RB5: 1272

RB5: 1272

4

DL_TFC4

UL_TFC4

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6

UL_TFC0, UL_TFC1,UL_TFC4,

UL_TFC6,

UL_TFC10

RB5: 2552

RB5: 2552

5

DL_TFC5

UL_TFC5

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6

UL_TFC0, UL_TFC1,UL_TFC5,

UL_TFC6,

UL_TFC11

RB5: 2872

RB5: 2872

NOTE 1: UL_TFC0, UL_TFC1, and UL_TFC6 are part of minimum set of TFCIs.

NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs.

See 18.3.1.1 for test procedure.

18.3.2.30.1.4 Test requirements

See 18.3.1.1 for definition of step 10 and step 15.

1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.

2. At step 15 the UE transmitted transport format shall be

– for sub-test 1: RB5/TF1 (1×336).

– for sub-test 2: RB5/TF2 (2×336).

– for sub-test 3: RB5/TF3 (4×336).

– for sub-test 4: RB5/TF4 (8×336).

– for sub-test 5: RB5/TF5 (9×336).

3. At step 15 the UE shall return

– for sub-test 1 to 5: an RLC SDU on RB5 having the same content as the DL RLC SDU sent by the SS.

18.3.2.30.2 Interactive or background / UL:144 DL:144 kbps / PS RAB + UL:3.4 DL: 3.4 kbps SRBs for DCCH / Payload 128, TTI 40 ms

18.3.2.30.2.1 Conformance requirement

See 18.3.2.4.1.

18.3.2.30.2.2 Test purpose

Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.11.6.4.1.30 for the uplink payload 128, TTI 40 ms case.

18.3.2.30.2.3 Method of test

Uplink TFS:

TFI

RB5

(144 kbps)

DCCH

TFS

TF0, bits

0x144

0x148

TF1, bits

1×144

1×148

TF2, bits

10×144

N/A

TF3, bits

20×144

N/A

TF4, bits

30×144

N/A

TF5, bits

45×144

N/A

Uplink TFCS:

TFCI

(RB5, DCCH)

UL_TFC0

(TF0, TF0)

UL_TFC1

(TF1, TF0)

UL_TFC2

(TF2, TF0)

UL_TFC3

(TF3, TF0)

UL_TFC4

(TF4, TF0)

UL_TFC5

(TF5, TF0)

UL_TFC6

(TF0, TF1)

UL_TFC7

(TF1, TF1)

UL_TFC8

(TF2, TF1)

UL_TFC9

(TF3, TF1)

UL_TFC10

(TF4, TF1)

UL_TFC11

(TF5, TF1)

Downlink TFS:

TFI

RB5

(144 kbps)

DCCH

TFS

TF0, bits

0x336

0x148

TF1, bits

1×336

1×148

TF2, bits

2×336

N/A

TF3, bits

4×336

N/A

TF4, bits

8×336

N/A

TF5, bits

9×336

N/A

Downlink TFCS:

TFCI

(RB5, DCCH)

DL_TFC0

(TF0, TF0)

DL_TFC1

(TF1, TF0)

DL_TFC2

(TF2, TF0)

DL_TFC3

(TF3, TF0)

DL_TFC4

(TF4, TF0)

DL_TFC5

(TF5, TF0)

DL_TFC6

(TF0, TF1)

DL_TFC7

(TF1, TF1)

DL_TFC8

(TF2, TF1)

DL_TFC9

(TF3, TF1)

DL_TFC10

(TF4, TF1)

DL_TFC11

(TF5, TF1)

Sub-tests:

Sub-test

Downlink TFCS

Under test

Uplink TFCS

Under test

Implicitly tested

Restricted UL TFCIs

(note 1)

UL RLC SDU size

(bits)

(note 2)

Test data size

(bits)

(note 2)

1

DL_TFC1

UL_TFC1

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6

UL_TFC0, UL_TFC1,

UL_TFC6,

UL_TFC7

RB5: 376

RB5: 312

2

DL_TFC2

UL_TFC2

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6

UL_TFC0, UL_TFC1,UL_TFC2,

UL_TFC6,

UL_TFC8

RB5: 1272

RB5: 632

3

DL_TFC3

UL_TFC3

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6

UL_TFC0, UL_TFC1,UL_TFC3,

UL_TFC6,

UL_TFC9

RB5: 2552

RB5: 1272

4

DL_TFC4

UL_TFC4

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6

UL_TFC0, UL_TFC1,UL_TFC4,

UL_TFC6,

UL_TFC10

RB5: 3832

RB5: 2552

5

DL_TFC5

UL_TFC5

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6

UL_TFC0, UL_TFC1,UL_TFC5,

UL_TFC6,

UL_TFC11

RB5: 5752

RB5: 2872

NOTE 1: UL_TFC0, UL_TFC1, and UL_TFC6 are part of minimum set of TFCIs.

NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs.

See 18.3.1.1 for test procedure.

18.3.2.30.2.4 Test requirements

See 18.3.1.1 for definition of step 10 and step 15.

1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.

2. At step 15 the UE transmitted transport format shall be

– for sub-test 1: RB5/TF1 (1×144).

– for sub-test 2: RB5/TF2 (10×144).

– for sub-test 3: RB5/TF3 (20×144).

– for sub-test 4: RB5/TF4 (30×144).

– for sub-test 5: RB5/TF5 (45×144).

3. At step 15 the UE shall return

– for sub-test 1: an RLC SDU on RB5 having the same content as 1 times plus 64 lsb’s of the DL RLC SDU sent by the SS.

– for sub-test 2: an RLC SDU on RB5 having the same content as 1 times plus 640 lsb’s of the DL RLC SDU sent by the SS.

– for sub-test 3: an RLC SDU on RB5 having the same content as 1 times plus 1280 lsb’s of the DL RLC SDU sent by the SS.

– for sub-test 4: an RLC SDU on RB5 having the same content as 1 times plus 1280 lsb’s of the DL RLC SDU sent by the SS.

– for sub-test 5: an RLC SDU on RB5 having the same content as 1 times plus 2880 lsb’s of the DL RLC SDU sent by the SS.

18.3.2.31 Interactive or background / UL:64 DL:256 kbps / PS RAB + UL:3.4 DL: 3.4 kbps SRBs for DCCH

18.3.2.31.1 Interactive or background / UL:64 DL:256 kbps / PS RAB + UL:3.4 DL: 3.4 kbps SRBs for DCCH/ Payload 320, 10 ms TTI Down Link, Physical Configuration 1

18.3.2.31.1.1 Conformance requirement

See 18.3.2.4.1.

18.3.2.31.1.2 Test purpose

Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.11.6.4.1.31 for the uplink payload 320, the downlink 10 ms TTI, and physical configuration 1 case.

18.3.2.31.1.3 Method of test

Uplink TFS:

TFI

RB5

(64 kbps)

DCCH

TFS

TF0, bits

0x336

0x148

TF1, bits

1×336

1×148

TF2, bits

2×336

N/A

TF3, bits

3×336

N/A

TF4, bits

4×336

N/A

Uplink TFCS:

TFCI

(RB5, DCCH)

UL_TFC0

(TF0, TF0)

UL_TFC1

(TF1, TF0)

UL_TFC2

(TF2, TF0)

UL_TFC3

(TF3, TF0)

UL_TFC4

(TF4, TF0)

UL_TFC5

(TF0, TF1)

UL_TFC6

(TF1, TF1)

UL_TFC7

(TF2, TF1)

UL_TFC8

(TF3, TF1)

UL_TFC9

(TF4, TF1)

Physical channel parameters

DPCH Uplink

Physical Configuration 1

Midamble

512 chips

Codes and time slots

SF16 x 1 code x 1 time slot + SF4 x 1 code x 1 time slot

Max. Number of data bits/radio frame

1148 bits

TFCI code word

16 bits

TPC

2 bits

Puncturing Limit

0.48 (alt. 0.44)

Downlink TFS:

TFI

RB5

(256 kbps, 10ms)

DCCH

TFS

TF0, bits

0x336

0x148

TF1, bits

1×336

1×148

TF2, bits

2×336

N/A

TF3, bits

4×336

N/A

TF4, bits

8×336

N/A

Downlink TFCS:

TFCI

(RB5, DCCH)

DL_TFC0

(TF0, TF0)

DL_TFC1

(TF1, TF0)

DL_TFC2

(TF2, TF0)

DL_TFC3

(TF3, TF0)

DL_TFC4

(TF4, TF0)

DL_TFC5

(TF0, TF1)

DL_TFC6

(TF1, TF1)

DL_TFC7

(TF2, TF1)

DL_TFC8

(TF3, TF1)

DL_TFC9

(TF4, TF1)

Sub-tests:

Sub-test

Downlink TFCS

Under test

Uplink TFCS

Under test

Implicitly tested

Restricted UL TFCIs

(note 1)

UL RLC SDU size

(bits)

(note 2)

Test data size

(bits)

(note 2)

1

DL_TFC1

UL_TFC1

DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,

UL_TFC5,

UL_TFC6

RB5: 312

RB5: 312

2

DL_TFC2

UL_TFC2

DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,

UL_TFC2,

UL_TFC5,

UL_TFC7

RB5: 632

RB5: 632

3

DL_TFC3

UL_TFC3

DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,

UL_TFC3,

UL_TFC5,

UL_TFC8

RB5: 1912

RB5: 1272

4

DL_TFC4

UL_TFC4

DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,

UL_TFC4,

UL_TFC5,

UL_TFC9

RB5: 2552

RB5: 2552

NOTE 1: UL_TFC0, UL_TFC1 and UL_TFC5 are part of minimum set of TFCIs.

NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs.
RB5: Test data size has been set to the payload size of the DL TF under test minus 8 bits (size of 7 bit length indicator and expansion bit). The UL RLC SDU size parameter has been set to achieve verification of all test data sent by SS in downlink, i.e. UL RLC SDU size is set to nearest multiple of the payload size of the UL TF under test minus 8 bits (size of 7 bit length indicator and expansion bit) which is equal or bigger than the test data size.

See 18.3.1.1 for test procedure.

18.3.2.31.1.4 Test requirements

See 18.3.1.1 for definition of step 10 and step 15.

1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.

2. At step 15 the UE transmitted transport format shall be

– for sub-test 1: RB5/TF1 (1×336).

– for sub-test 2: RB5/TF2 (2×336) or RB5/TF1 (1×336).

– for sub-test 3: RB5/TF3 (3×336) or RB5/TF1 (1×336).

– for sub-test 4: RB5/TF4 (4×336) or RB5/TF1 (1×336).

3. At step 15 the UE shall return

– for sub-test 1, 2 and 4: an RLC SDU on RB5 having the same content as the DL RLC SDU sent by the SS.

– for sub-test 3: an RLC SDU on RB5 having the same content as 1 times plus 640 lsb’s of the DL RLC SDU sent by the SS.

18.3.2.31.2 Interactive or background / UL:64 DL:256 kbps / PS RAB / Payload 128, 20 ms TTI Down Link, Physical Configuration 2

18.3.2.31.2.1 Conformance requirement

See 18.3.2.4.1.

18.3.2.31.2.2 Test purpose

Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.11.6.4.1.31 for the uplink payload 128, the downlink 20 ms TTI, and physical configuration 2 case.

18.3.2.31.2.3 Method of test

Uplink TFS:

TFI

RB5

(64 kbps)

DCCH

TFS

TF0, bits

0x144

0x148

TF1, bits

1×144

1×148

TF2, bits

3×144

N/A

TF3, bits

7×144

N/A

TF4, bits

10×144

N/A

Uplink TFCS:

TFCI

(RB5, DCCH)

UL_TFC0

(TF0, TF0)

UL_TFC1

(TF1, TF0)

UL_TFC2

(TF2, TF0)

UL_TFC3

(TF3, TF0)

UL_TFC4

(TF4, TF0)

UL_TFC5

(TF0, TF1)

UL_TFC6

(TF1, TF1)

UL_TFC7

(TF2, TF1)

UL_TFC8

(TF3, TF1)

UL_TFC9

(TF4, TF1)

Physical channel parameters

DPCH Uplink

Physical Configuration 2

Midamble

512 chips

Codes and time slots

SF2 x 1 code x 1 time slot + SF4 x 1 code x 1 time slot

Max. Number of data bits/radio frame

2784 bits

TFCI code word

16 bits

TPC

2 bits

Puncturing Limit

1

Downlink TFS:

TFI

RB5

(256 kbps, 20ms)

DCCH

TFS

TF0, bits

0x336

0x148

TF1, bits

1×336

1×148

TF2, bits

2×336

N/A

TF3, bits

4×336

N/A

TF4, bits

8×336

N/A

TF5, bits

12×336

N/A

TF6, bits

16×336

N/A

Downlink TFCS:

TFCI

(RB5, DCCH)

DL_TFC0

(TF0, TF0)

DL_TFC1

(TF1, TF0)

DL_TFC2

(TF2, TF0)

DL_TFC3

(TF3, TF0)

DL_TFC4

(TF4, TF0)

DL_TFC5

(TF5, TF0)

DL_TFC6

(TF6, TF0)

DL_TFC7

(TF0, TF1)

DL_TFC8

(TF1, TF1)

DL_TFC9

(TF2, TF1)

DL_TFC10

(TF3, TF1)

DL_TFC11

(TF4, TF1)

DL_TFC12

(TF5, TF1)

DL_TFC13

(TF6, TF1)

Sub-tests:

Sub-test

Downlink TFCS

Under test

Uplink TFCS

Under test

Implicitly tested

Restricted UL TFCIs

(note 1)

UL RLC SDU size

(bits)

(note 2)

Test data size

(bits)

(note 2)

1

DL_TFC1

UL_TFC1

DL_TFC0, DL_TFC7, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,

UL_TFC5,

UL_TFC6

RB5: 376

RB5: 312

2

DL_TFC2

UL_TFC2

DL_TFC0, DL_TFC7, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1, UL_TFC2,

UL_TFC5,

UL_TFC7

RB5: 760

RB5: 632

3

DL_TFC3

UL_TFC3

DL_TFC0, DL_TFC7, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1, UL_TFC3,

UL_TFC5,

UL_TFC8

RB5: 1784

RB5: 1272

4

DL_TFC4

UL_TFC4

DL_TFC0, DL_TFC7, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1, UL_TFC4,

UL_TFC5,

UL_TFC9

RB5: 2552

RB5: 2552

5

DL_TFC5

UL_TFC4

DL_TFC0, DL_TFC7, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1, UL_TFC4,

UL_TFC5,

UL_TFC9

RB5: 3832

RB5: 3832

6

DL_TFC6

UL_TFC4

DL_TFC0, DL_TFC7, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1, UL_TFC4,

UL_TFC5,

UL_TFC9

RB5: 5112

RB5: 5112

NOTE 1: UL_TFC0, UL_TFC1, and UL_TFC5 are part of minimum set of TFCIs.

NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs.

See 18.3.1.1 for test procedure.

18.3.2.31.2.4 Test requirements

See 18.3.1.1 for definition of step 10 and step 15.

1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.

2. At step 15 the UE transmitted transport format shall be

– for sub-test 1: RB5/TF1 (1×144).

– for sub-test 2: RB5/TF2 (3×144).

– for sub-test 3: RB5/TF3 (7×144).

– for sub-test 4 to 6: RB5/TF4 (10×144).

3. At step 15 the UE shall return

– for sub-test 1: an RLC SDU on RB5 having the same content as 1 times plus 64 lsb’s of the DL RLC SDU sent by the SS.

– for sub-test 2: an RLC SDU on RB5 having the same content as 1 times plus 128 lsb’s of the DL RLC SDU sent by the SS.

– for sub-test 3: an RLC SDU on RB5 having the same content as 1 times plus 512 lsb’s of the DL RLC SDU sent by the SS.

– for sub-test 4 to 6: an RLC SDU on RB5 having the same content as the DL RLC SDU sent by the SS.

18.3.2.32 Interactive or background / UL:64 DL:384 kbps / PS RAB + UL:3.4 DL: 3.4 kbps SRBs for DCCH

18.3.2.32.1 Interactive or background / UL:64 DL:384 kbps / PS RAB / Payload 320, 10 ms TTI Down Link, Physical Configuration 1

18.3.2.32.1.1 Conformance requirement

See 18.3.2.4.1.

18.3.2.32.1.2 Test purpose

Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.11.6.4.1.32 for the uplink payload 320, the downlink 10 ms TTI, and physical configuration 1 case.

18.3.2.32.1.3 Method of test

Uplink TFS:

TFI

RB5

(64 kbps)

DCCH

TFS

TF0, bits

0x336

0x148

TF1, bits

1×336

1×148

TF2, bits

2×336

N/A

TF3, bits

3×336

N/A

TF4, bits

4×336

N/A

Uplink TFCS:

TFCI

(RB5, DCCH)

UL_TFC0

(TF0, TF0)

UL_TFC1

(TF1, TF0)

UL_TFC2

(TF2, TF0)

UL_TFC3

(TF3, TF0)

UL_TFC4

(TF4, TF0)

UL_TFC5

(TF0, TF1)

UL_TFC6

(TF1, TF1)

UL_TFC7

(TF2, TF1)

UL_TFC8

(TF3, TF1)

UL_TFC9

(TF4, TF1)

Physical channel parameters

DPCH Uplink

Physical Configuration 1

Midamble

512 chips

Codes and time slots

SF16 x 1 code x 1 time slot + SF4 x 1 code x 1 time slot

Max. Number of data bits/radio frame

1148 bits

TFCI code word

16 bits

TPC

2 bits

Puncturing Limit

0.48 (alt. 0.44)

Downlink TFS:

TFI

RB5

(384 kbps, 10ms)

DCCH

TFS

TF0, bits

0x336

0x148

TF1, bits

1×336

1×148

TF2, bits

2×336

N/A

TF3, bits

4×336

N/A

TF4, bits

8×336

N/A

TF5, bits

12×336

N/A

Downlink TFCS:

TFCI

(RB5, DCCH)

DL_TFC0

(TF0, TF0)

DL_TFC1

(TF1, TF0)

DL_TFC2

(TF2, TF0)

DL_TFC3

(TF3, TF0)

DL_TFC4

(TF4, TF0)

DL_TFC5

(TF5, TF0)

DL_TFC6

(TF0, TF1)

DL_TFC7

(TF1, TF1)

DL_TFC8

(TF2, TF1)

DL_TFC9

(TF3, TF1)

DL_TFC10

(TF4, TF1)

DL_TFC11

(TF5, TF1)

Physical channel parameters

DPCH Downlink

Physical Configuration 1

Midamble

256 chips

Codes and time slots

SF16 x 8 codes x 3 time slots

Max. Number of data

bits/radio frame

6608 bits

TFCI code word

16 bits

Puncturing Limit

0.48

Sub-tests:

Sub-test

Downlink TFCS

Under test

Uplink TFCS

Under test

Implicitly tested

Restricted UL TFCIs

(note 1)

UL RLC SDU size

(bits)

(note 1)

Test data size

(bits)

(note 1)

1

DL_TFC1

UL_TFC1

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,

UL_TFC5,

UL_TFC6

RB5: 312

RB5: 312

2

DL_TFC2

UL_TFC2

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,

UL_TFC2,

UL_TFC5,

UL_TFC7

RB5: 632

RB5: 632

3

DL_TFC3

UL_TFC3

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,

UL_TFC3,

UL_TFC5,

UL_TFC8

RB5: 1912

RB5: 1272

4

DL_TFC4

UL_TFC4

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,

UL_TFC4,

UL_TFC5,

UL_TFC9

RB5: 2552

RB5: 2552

5

DL_TFC5

UL_TFC4

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,

UL_TFC4,

UL_TFC5,

UL_TFC9

RB5: 3832

RB5: 3832

NOTE 1: UL_TFC0, UL_TFC1 and UL_TFC5 are part of minimum set of TFCIs.

NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs.
RB5: Test data size has been set to the payload size of the DL TF under test minus 8 bits (size of 7 bit length indicator and expansion bit). The UL RLC SDU size parameter has been set to achieve verification of all test data sent by SS in downlink, i.e. UL RLC SDU size is set to nearest multiple of the payload size of the UL TF under test minus 8 bits (size of 7 bit length indicator and expansion bit) which is equal or bigger than the test data size.

See 18.3.1.1 for test procedure.

18.3.2.32.1.4 Test requirements

See 18.3.1.1 for definition of step 10 and step 15.

1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.

2. At step 15 the UE transmitted transport format shall be

– for sub-test 1: RB5/TF1 (1×336).

– for sub-test 2: RB5/TF2 (2×336) or RB5/TF1 (1×336).

– for sub-test 3: RB5/TF3 (3×336) or RB5/TF1 (1×336).

– for sub-test 4 and 5: RB5/TF4 (4×336) or RB5/TF1 (1×336).

3. At step 15 the UE shall return

– for sub-test 1, 2, 4 and 5: an RLC SDU on RB5 having the same content as the DL RLC SDU sent by the SS.

– for sub-test 3: an RLC SDU on RB5 having the same content as 1 times plus 640 lsb’s of the DL RLC SDU sent by the SS.

18.3.2.32.2 Interactive or background / UL:64 DL:384 kbps / PS RAB / Payload 128, 20 ms TTI Down Link, Physical Configuration 2

18.3.2.32.2.1 Conformance requirement

See 18.3.2.4.1.

18.3.2.32.2.2 Test purpose

Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.11.6.4.1.32 for the uplink payload 128, the downlink 20 ms TTI, and physical configuration 2 case.

18.3.2.32.2.3 Method of test

Uplink TFS:

TFI

RB5

(64 kbps)

DCCH

TFS

TF0, bits

0x144

0x148

TF1, bits

1×144

1×148

TF2, bits

3×144

N/A

TF3, bits

7×144

N/A

TF4, bits

10×144

N/A

Uplink TFCS:

TFCI

(RB5, DCCH)

UL_TFC0

(TF0, TF0)

UL_TFC1

(TF1, TF0)

UL_TFC2

(TF2, TF0)

UL_TFC3

(TF3, TF0)

UL_TFC4

(TF4, TF0)

UL_TFC5

(TF0, TF1)

UL_TFC6

(TF1, TF1)

UL_TFC7

(TF2, TF1)

UL_TFC8

(TF3, TF1)

UL_TFC9

(TF4, TF1)

Physical channel parameters

DPCH Uplink

Physical Configuration 2

Midamble

512 chips

Codes and time slots

SF2 x 1 code x 1 time slot + SF4 x 1 code x 1 time slot

Max. Number of data bits/radio frame

2784 bits

TFCI code word

16 bits

TPC

2 bits

Puncturing Limit

1

Downlink TFS:

TFI

RB5

(384 kbps, 20ms)

DCCH

TFS

TF0, bits

0x336

0x148

TF1, bits

1×336

1×148

TF2, bits

2×336

N/A

TF3, bits

4×336

N/A

TF4, bits

8×336

N/A

TF5, bits

12×336

N/A

TF6, bits

16×336

N/A

TF7, bits

20×336

N/A

TF8, bits

24×336

N/A

Downlink TFCS:

TFCI

(RB5, DCCH)

DL_TFC0

(TF0, TF0)

DL_TFC1

(TF1, TF0)

DL_TFC2

(TF2, TF0)

DL_TFC3

(TF3, TF0)

DL_TFC4

(TF4, TF0)

DL_TFC5

(TF5, TF0)

DL_TFC6

(TF6, TF0)

DL_TFC7

(TF7, TF0)

DL_TFC8

(TF8, TF0)

DL_TFC9

(TF0, TF1)

DL_TFC10

(TF1, TF1)

DL_TFC11

(TF2, TF1)

DL_TFC12

(TF3, TF1)

DL_TFC13

(TF4, TF1)

DL_TFC14

(TF5, TF1)

DL_TFC15

(TF6, TF1)

DL_TFC16

(TF7, TF1)

DL_TFC17

(TF8, TF1)

Physical channel parameters

DPCH Downlink

Physical Configuration 2

Midamble

256 chips

Codes and time slots

SF16 x 6 codes x 4 time slots + SF16 x 4 codes x 1 time slot (alt. SF1 x 1 code x 3 time slots)

Max. Number of data

bits/radio frame

7712 bits (alt. 13232 bits)

TFCI code word

16 bits

Puncturing Limit

0.60 (alt. 1)

Sub-tests:

Sub-test

Downlink TFCS

Under test

Uplink TFCS

Under test

Implicitly tested

Restricted UL TFCIs

(note 1)

UL RLC SDU size

(bits)

(note 2)

Test data size

(bits)

(note 2)

1

DL_TFC1

UL_TFC1

DL_TFC0, DL_TFC9, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,

UL_TFC5,

UL_TFC6

RB5: 376

RB5: 312

2

DL_TFC2

UL_TFC2

DL_TFC0, DL_TFC9, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,UL_TFC2,

UL_TFC5,

UL_TFC7

RB5: 760

RB5: 632

3

DL_TFC3

UL_TFC3

DL_TFC0, DL_TFC9, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,UL_TFC3,

UL_TFC5,

UL_TFC8

RB5: 1784

RB5: 1272

4

DL_TFC4

UL_TFC4

DL_TFC0, DL_TFC9, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,UL_TFC4,

UL_TFC5,

UL_TFC9

RB5: 2552

RB5: 2552

5

DL_TFC5

UL_TFC4

DL_TFC0, DL_TFC9, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,UL_TFC4,

UL_TFC5,

UL_TFC9

RB5: 3832

RB5: 3832

6

DL_TFC6

UL_TFC4

DL_TFC0, DL_TFC9, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,UL_TFC4,

UL_TFC5,

UL_TFC9

RB5: 5112

RB5: 5112

7

DL_TFC7

UL_TFC4

DL_TFC0, DL_TFC9, , UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,UL_TFC4,

UL_TFC5,

UL_TFC9

RB5: 6392

RB5: 6392

8

DL_TFC8

UL_TFC4

DL_TFC0, DL_TFC9, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,UL_TFC4,

UL_TFC5,

UL_TFC9

RB5: 7672

RB5: 7672

NOTE 1: UL_TFC0, UL_TFC1, and UL_TFC5 are part of minimum set of TFCIs.

NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs.

See 18.3.1.1 for test procedure.

18.3.2.32.2.4 Test requirements

See 18.3.1.1 for definition of step 10 and step 15.

1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.

2. At step 15 the UE transmitted transport format shall be

– for sub-test 1: RB5/TF1 (1×144).

– for sub-test 2: RB5/TF2 (3×144).

– for sub-test 3: RB5/TF3 (7×144).

– for sub-test 4 to 8: RB5/TF4 (10×144).

3. At step 15 the UE shall return

– for sub-test 1: an RLC SDU on RB5 having the same content as 1 times plus 64 lsb’s of the DL RLC SDU sent by the SS.

– for sub-test 2: an RLC SDU on RB5 having the same content as 1 times plus 128 lsb’s of the DL RLC SDU sent by the SS.

– for sub-test 3: an RLC SDU on RB5 having the same content as 1 times plus 512 lsb’s of the DL RLC SDU sent by the SS.

– for sub-test 4 to 8: an RLC SDU on RB5 having the same content as the DL RLC SDU sent by the SS.

18.3.2.33 Interactive or background / UL:128 DL:384 kbps / PS RAB + UL:3.4 DL: 3.4 kbps SRBs for DCCH

18.3.2.33.1 Interactive or background / UL:128 DL:384 kbps / PS RAB / Payload 320, 10 ms TTI Down Link, Physical Configuration 1

18.3.2.33.1.1 Conformance requirement

See 18.3.2.4.1.

18.3.2.33.1.2 Test purpose

Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.11.6.4.1.33 for the uplink payload 320, the downlink 10 ms TTI, and physical configuration 1 case.

18.3.2.33.1.3 Method of test

Uplink TFS:

TFI

RB5

(128 kbps)

DCCH

TFS

TF0, bits

0x336

0x148

TF1, bits

1×336

1×148

TF2, bits

2×336

N/A

TF3, bits

4×336

N/A

TF4, bits

8×336

N/A

Uplink TFCS:

TFCI

(RB5, DCCH)

UL_TFC0

(TF0, TF0)

UL_TFC1

(TF1, TF0)

UL_TFC2

(TF2, TF0)

UL_TFC3

(TF3, TF0)

UL_TFC4

(TF4, TF0)

UL_TFC5

(TF0, TF1)

UL_TFC6

(TF1, TF1)

UL_TFC7

(TF2, TF1)

UL_TFC8

(TF3, TF1)

UL_TFC9

(TF4, TF1)

Physical channel parameters

DPCH Uplink

Physical Configuration 1

Midamble

256 chips

Codes and time slots

SF2 x 1 code x 1 timeslot

Max. Number of data bits/radio frame

2064 bits

TFCI code word

16 bits

TPC

2 bits

Puncturing Limit

0.44 (alt. 0.40)

Downlink TFS:

TFI

RB5

(384 kbps, 10ms)

DCCH

TFS

TF0, bits

0x336

0x148

TF1, bits

1×336

1×148

TF2, bits

2×336

N/A

TF3, bits

4×336

N/A

TF4, bits

8×336

N/A

TF5, bits

12×336

N/A

Downlink TFCS:

TFCI

(RB5, DCCH)

DL_TFC0

(TF0, TF0)

DL_TFC1

(TF1, TF0)

DL_TFC2

(TF2, TF0)

DL_TFC3

(TF3, TF0)

DL_TFC4

(TF4, TF0)

DL_TFC5

(TF5, TF0)

DL_TFC6

(TF0, TF1)

DL_TFC7

(TF1, TF1)

DL_TFC8

(TF2, TF1)

DL_TFC9

(TF3, TF1)

DL_TFC10

(TF4, TF1)

DL_TFC11

(TF5, TF1)

Physical channel parameters

DPCH Downlink

Physical Configuration 1

Midamble

256 chips

Codes and time slots

SF16 x 8 codes x 3 time slots

Max. Number of data

bits/radio frame

6608 bits

TFCI code word

16 bits

Puncturing Limit

0.48

Sub-tests:

Sub-test

Downlink TFCS

Under test

Uplink TFCS

Under test

Implicitly tested

Restricted UL TFCIs

(note 1)

UL RLC SDU size

(bits)

(note 2)

Test data size

(bits)

(note 2)

1

DL_TFC1

UL_TFC1

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,

UL_TFC5,

UL_TFC6

RB5: 312

RB5: 312

2

DL_TFC2

UL_TFC2

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,UL_TFC2,

UL_TFC5,

UL_TFC7

RB5: 632

RB5: 632

3

DL_TFC3

UL_TFC3

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,UL_TFC3,

UL_TFC5,

UL_TFC8

RB5: 1272

RB5: 1272

4

DL_TFC4

UL_TFC4

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,UL_TFC4,

UL_TFC5,

UL_TFC9

RB5: 2552

RB5: 2552

5

DL_TFC5

UL_TFC3

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,UL_TFC3,

UL_TFC5,

UL_TFC8

RB5: 3832

RB5: 3832

NOTE 1: UL_TFC0, UL_TFC1, and UL_TFC5 are part of minimum set of TFCIs.

NOTE2 : See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs.
The UL RLC SDU size have been chosen such that the UE will return all data received in downlink and that the UL RLC SDU will fill up the uplink transport format set under test over one or several transmission time intervals.

See 18.3.1.1 for test procedure.

18.3.2.33.1.4 Test requirements

See 18.3.1.1 for definition of step 10 and step 15.

1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.

2. At step 15 the UE transmitted transport format shall be

– for sub-test 1: RB5/TF1 (1×336).

– for sub-test 2: RB5/TF2 (2×336).

– for sub-test 3: RB5/TF3 (4×336).

– for sub-test 4 and 5: RB5/TF4 (8×336).

3. At step 15 the UE shall return

– for sub-test 1 to 5: an RLC SDU on RB5 having the same content as the DL RLC SDU sent by the SS.

18.3.2.33.2 Interactive or background / UL:128 DL:384 kbps / PS RAB / Payload 128, 20 ms TTI Down Link, Physical Configuration 2

18.3.2.33.2.1 Conformance requirement

See 18.3.2.4.1.

18.3.2.33.2.2 Test purpose

Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.11.6.4.1.33 for the uplink payload 128, the downlink 20 ms TTI, and physical configuration 2 case.

18.3.2.33.2.3 Method of test

Uplink TFS:

TFI

RB5

(128 kbps)

DCCH

TFS

TF0, bits

0x144

0x148

TF1, bits

1×144

1×148

TF2, bits

7×144

N/A

TF3, bits

14×144

N/A

TF4, bits

20×144

N/A

Uplink TFCS:

TFCI

(RB5, DCCH)

UL_TFC0

(TF0, TF0)

UL_TFC1

(TF1, TF0)

UL_TFC2

(TF2, TF0)

UL_TFC3

(TF3, TF0)

UL_TFC4

(TF4, TF0)

UL_TFC5

(TF0, TF1)

UL_TFC6

(TF1, TF1)

UL_TFC7

(TF2, TF1)

UL_TFC8

(TF3, TF1)

UL_TFC9

(TF4, TF1)

Physical channel parameters

DPCH Uplink

Physical Configuration 2

Midamble

256 chips

Codes and time slots

SF2 x 1 code x 2 timeslots + SF4 x 1 code x 1 time slot

Max. Number of data bits/radio frame

5376 bits

TFCI code word

16 bits

TPC

2 bits

Puncturing Limit

1

Downlink TFS:

TFI

RB5

(384 kbps, 20ms)

DCCH

TFS

TF0, bits

0x336

0x148

TF1, bits

1×336

1×148

TF2, bits

2×336

N/A

TF3, bits

4×336

N/A

TF4, bits

8×336

N/A

TF5, bits

12×336

N/A

TF6, bits

16×336

N/A

TF7, bits

20×336

N/A

TF8, bits

24×336

N/A

Downlink TFCS:

TFCI

(RB5, DCCH)

DL_TFC0

(TF0, TF0)

DL_TFC1

(TF1, TF0)

DL_TFC2

(TF2, TF0)

DL_TFC3

(TF3, TF0)

DL_TFC4

(TF4, TF0)

DL_TFC5

(TF5, TF0)

DL_TFC6

(TF6, TF0)

DL_TFC7

(TF7, TF0)

DL_TFC8

(TF8, TF0)

DL_TFC9

(TF0, TF1)

DL_TFC10

(TF1, TF1)

DL_TFC11

(TF2, TF1)

DL_TFC12

(TF3, TF1)

DL_TFC13

(TF4, TF1)

DL_TFC14

(TF5, TF1)

DL_TFC15

(TF6, TF1)

DL_TFC16

(TF7, TF1)

DL_TFC17

(TF8, TF1)

Physical channel parameters

DPCH Downlink

Physical Configuration 2

Midamble

256 chips

Codes and time slots

SF16 x 6 codes x 4 time slots + SF16 x 4 codes x 1 time slot (alt. SF1 x 1 code x 3 time slots)

Max. Number of data

bits/radio frame

7712 bits (alt. 13232 bits)

TFCI code word

16 bits

Puncturing Limit

0.60 (alt. 1)

Sub-tests:

Sub-test

Downlink TFCS

Under test

Uplink TFCS

Under test

Implicitly tested

Restricted UL TFCIs

(note 1)

UL RLC SDU size

(bits)

(note 2)

Test data size

(bits)

(note 2)

1

DL_TFC1

UL_TFC1

DL_TFC0, DL_TFC9, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,

UL_TFC5,

UL_TFC6

RB5: 376

RB5: 312

2

DL_TFC2

UL_TFC2

DL_TFC0, DL_TFC9, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1, UL_TFC2,

UL_TFC5,

UL_TFC7

RB5: 888

RB5: 632

3

DL_TFC3

UL_TFC3

DL_TFC0, DL_TFC9, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1, UL_TFC3,

UL_TFC5,

UL_TFC8

RB5: 1784

RB5: 1272

4

DL_TFC4

UL_TFC4

DL_TFC0, DL_TFC9, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1, UL_TFC4,

UL_TFC5,

UL_TFC9

RB5: 2552

RB5: 2552

5

DL_TFC5

UL_TFC4

DL_TFC0, DL_TFC9, UL_TFC0, UL_TFC5,

UL_TFC0, UL_TFC1, UL_TFC4,

UL_TFC5,

UL_TFC9

RB5: 5112

RB5: 3832

6

DL_TFC6

UL_TFC4

DL_TFC0, DL_TFC9, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1, UL_TFC4,

UL_TFC5,

UL_TFC9

RB5: 5112

RB5: 5112

7

DL_TFC7

UL_TFC4

DL_TFC0, DL_TFC9, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1, UL_TFC4,

UL_TFC5,

UL_TFC9

RB5: 7672

RB5: 6392

8

DL_TFC8

UL_TFC4

DL_TFC0, DL_TFC9, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1, UL_TFC4

UL_TFC5,

UL_TFC9

RB5: 7672

RB5: 7672

NOTE 1: UL_TFC0, UL_TFC1, and UL_TFC5 are part of minimum set of TFCIs.

NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs.
The UL RLC SDU size have been chosen such that the UE will return all data received in downlink and that the UL RLC SDU will fill up the uplink transport format set under test over one or several transmission time intervals.

See 18.3.1.1 for test procedure.

18.3.2.33.2.4 Test requirements

See 18.3.1.1 for definition of step 10 and step 15.

1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.

2. At step 15 the UE transmitted transport format shall be

– for sub-test 1: RB5/TF1 (1×144).

– for sub-test 2: RB5/TF2 (7×144).

– for sub-test 3: RB5/TF3 (14×144).

– for sub-test 4 to 8: RB5/TF4 (20×144).

3. At step 15 the UE shall return

– for sub-test 1: an RLC SDU on RB5 having the same content as 1 times plus 64 lsb’s of the DL RLC SDU sent by the SS.

– for sub-test 2: an RLC SDU on RB5 having the same content as 1 times plus 256 lsb’s of the DL RLC SDU sent by the SS.

– for sub-test 3: an RLC SDU on RB5 having the same content as 1 times plus 512 lsb’s of the DL RLC SDU sent by the SS.

– for sub-test 4, 6, and 8: an RLC SDU on RB5 having the same content as the DL RLC SDU sent by the SS.

– for sub-test 5: an RLC SDU on RB5 having the same content as 1 times plus 1280 lsb’s of the DL RLC SDU sent by the SS.

– for sub-test 7: an RLC SDU on RB5 having the same content as 1 times plus 1280 lsb’s of the DL RLC SDU sent by the SS.

18.3.2.34 Interactive or background / UL:384 DL:384 kbps / PS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH

18.3.2.34.1 Interactive or background / UL:384 DL:384 kbps / PS RAB / 10 ms TTI, Physical Configuration 1

18.3.2.34.1.1 Conformance requirement

See 18.3.2.4.1.

18.3.2.34.1.2 Test purpose

Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.11.6.4.1.34 for the 10 ms TTI, physical configuration 1 case.

18.3.2.34.1.3 Method of test

Uplink TFS:

TFI

RB5

(384 kbps, 10ms)

DCCH

TFS

TF0, bits

0x336

0x148

TF1, bits

1×336

1×148

TF2, bits

2×336

N/A

TF3, bits

4×336

N/A

TF4, bits

8×336

N/A

TF5, bits

12×336

N/A

Uplink TFCS:

TFCI

(RB5, DCCH)

UL_TFC0

(TF0, TF0)

UL_TFC1

(TF1, TF0)

UL_TFC2

(TF2, TF0)

UL_TFC3

(TF3, TF0)

UL_TFC4

(TF4, TF0)

UL_TFC5

(TF5, TF0)

UL_TFC6

(TF0, TF1)

UL_TFC7

(TF1, TF1)

UL_TFC8

(TF2, TF1)

UL_TFC9

(TF3, TF1)

UL_TFC10

(TF4, TF1)

UL_TFC11

(TF5, TF1)

Physical channel parameters

DPCH Uplink

Physical Configuration 1

Midamble

256 chips

Codes and time slots

SF2 x 1 code x 3 time slots

Max. Number of data

bits/radio frame

6480 bits

TFCI code word

16 bits

TPC

2 bits

Puncturing Limit

0.48

Downlink TFS:

TFI

RB5

(384 kbps, 10ms)

DCCH

TFS

TF0, bits

0x336

0x148

TF1, bits

1×336

1×148

TF2, bits

2×336

N/A

TF3, bits

4×336

N/A

TF4, bits

8×336

N/A

TF5, bits

12×336

N/A

Downlink TFCS:

TFCI

(RB5, DCCH)

DL_TFC0

(TF0, TF0)

DL_TFC1

(TF1, TF0)

DL_TFC2

(TF2, TF0)

DL_TFC3

(TF3, TF0)

DL_TFC4

(TF4, TF0)

DL_TFC5

(TF5, TF0)

DL_TFC6

(TF0, TF1)

DL_TFC7

(TF1, TF1)

DL_TFC8

(TF2, TF1)

DL_TFC9

(TF3, TF1)

DL_TFC10

(TF4, TF1)

DL_TFC11

(TF5, TF1)

Physical channel parameters

DPCH Downlink

Physical Configuration 1

Midamble

256 chips

Codes and time slots

SF16 x 8 codes x 3 time slots

Max. Number of data

bits/radio frame

6608 bits

TFCI code word

16 bits

Puncturing Limit

0.48

Sub-tests:

Sub-test

Downlink TFCS

Under test

Uplink TFCS

Under test

Implicitly tested

Restricted UL TFCIs

(note 1)

UL RLC SDU size

(bits)

(note 2)

Test data size

(bits)

(note 2)

1

DL_TFC1

UL_TFC1

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6

UL_TFC0, UL_TFC1,

UL_TFC6,

UL_TFC7

RB5: 312

RB5: 312

2

DL_TFC2

UL_TFC2

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6

UL_TFC0, UL_TFC1,

UL_TFC2,

UL_TFC6,

UL_TFC8

RB5: 632

RB5: 632

3

DL_TFC3

UL_TFC3

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6

UL_TFC0, UL_TFC1,UL_TFC3,

UL_TFC6,

UL_TFC9

RB5: 1272

RB5: 1272

4

DL_TFC4

UL_TFC4

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6

UL_TFC0, UL_TFC1,UL_TFC4,

UL_TFC6,

UL_TFC10

RB5: 2552

RB5: 2552

5

DL_TFC5

UL_TFC5

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6

UL_TFC0, UL_TFC1,UL_TFC5,

UL_TFC6,

UL_TFC11

RB5: 3832

RB5: 3832

NOTE 1: UL_TFC0, UL_TFC1 and UL_TFC6 are part of minimum set of TFCIs.

NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs.

See 18.3.1.1 for test procedure.

18.3.2.34.1.4 Test requirements

See 18.3.1.1 for definition of step 10 and step 15.

1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.

2. At step 15 the UE transmitted transport format shall be

– for sub-test 1: RB5/TF1 (1×336).

– for sub-test 2: RB5/TF2 (2×336).

– for sub-test 3: RB5/TF3 (4×336).

– for sub-test 4: RB5/TF4 (8×336).

– for sub-test 5: RB5/TF4 (12×336).

3. At step 15 the UE shall return

– for sub-test 1 to 5: an RLC SDU on RB5 having the same content as the DL RLC SDU sent by the SS.

18.3.2.34.2 Interactive or background / UL:384 DL:384 kbps / PS RAB / 20 ms TTI, Physical Configuration 2

18.3.2.34.2.1 Conformance requirement

See 18.3.2.4.1.

18.3.2.34.2.2 Test purpose

Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.11.6.4.1.34. for the 20 ms TTI, physical configuration 2 case

18.3.2.34.2.3 Method of test

Uplink TFS:

TFI

RB5

(384 kbps, 20ms)

DCCH

TFS

TF0, bits

0x336

0x148

TF1, bits

1×336

1×148

TF2, bits

2×336

N/A

TF3, bits

4×336

N/A

TF4, bits

8×336

N/A

TF5, bits

12×336

N/A

TF6, bits

16×336

N/A

TF7, bits

20×336

N/A

TF8, bits

24×336

N/A

Uplink TFCS:

TFCI

(RB5, DCCH)

UL_TFC0

(TF0, TF0)

UL_TFC1

(TF1, TF0)

UL_TFC2

(TF2, TF0)

UL_TFC3

(TF3, TF0)

UL_TFC4

(TF4, TF0)

UL_TFC5

(TF5, TF0)

UL_TFC6

(TF6, TF0)

UL_TFC7

(TF7, TF0)

UL_TFC8

(TF8, TF0)

UL_TFC9

(TF0, TF1)

UL_TFC10

(TF1, TF1)

UL_TFC11

(TF2, TF1)

UL_TFC12

(TF3, TF1)

UL_TFC13

(TF4, TF1)

UL_TFC14

(TF5, TF1)

UL_TFC15

(TF6, TF1)

UL_TFC16

(TF7, TF1)

UL_TFC17

(TF8, TF1)

Physical channel parameters

DPCH Uplink

Physical Configuration 2

Midamble

256 chips

Codes and time slots

SF2 x 1 code x 5 timeslots + SF4 x 1 code x 2 timeslots (alt. {SF2 x 1 code + SF4 x 1 code} x 4 timeslots)

Max. Number of data

bits/radio frame

13104 bits

TFCI code word

16 bits

TPC

2 bits

Puncturing Limit

1

Downlink TFS:

TFI

RB5

(384 kbps, 20ms)

DCCH

TFS

TF0, bits

0x336

0x148

TF1, bits

1×336

1×148

TF2, bits

2×336

N/A

TF3, bits

4×336

N/A

TF4, bits

8×336

N/A

TF5, bits

12×336

N/A

TF6, bits

16×336

N/A

TF7, bits

20×336

N/A

TF8, bits

24×336

N/A

Downlink TFCS:

TFCI

(RB5, DCCH)

DL_TFC0

(TF0, TF0)

DL_TFC1

(TF1, TF0)

DL_TFC2

(TF2, TF0)

DL_TFC3

(TF3, TF0)

DL_TFC4

(TF4, TF0)

DL_TFC5

(TF5, TF0)

DL_TFC6

(TF6, TF0)

DL_TFC7

(TF7, TF0)

DL_TFC8

(TF8, TF0)

DL_TFC9

(TF0, TF1)

DL_TFC10

(TF1, TF1)

DL_TFC11

(TF2, TF1)

DL_TFC12

(TF3, TF1)

DL_TFC13

(TF4, TF1)

DL_TFC14

(TF5, TF1)

DL_TFC15

(TF6, TF1)

DL_TFC16

(TF7, TF1)

DL_TFC17

(TF8, TF1)

Physical channel parameters

DPCH Downlink

Physical Configuration 2

Midamble

256 chips

Codes and time slots

SF16 x 6 codes x 4 time slots + SF16 x 4 codes x 1 time slot (alt. SF1 x 1 code x 3 time slots)

Max. Number of data

bits/radio frame

7712 bits (alt. 13232 bits)

TFCI code word

16 bits

Puncturing Limit

0.60 (alt. 1)

Sub-tests:

Sub-test

Downlink TFCS

Under test

Uplink TFCS

Under test

Implicitly tested

Restricted UL TFCIs

(note 1)

UL RLC SDU size

(bits)

(note 2)

Test data size

(bits)

(note 2)

1

DL_TFC1

UL_TFC1

DL_TFC0, DL_TFC9, UL_TFC0, UL_TFC9

UL_TFC0, UL_TFC1,

UL_TFC9,

UL_TFC10

RB5: 312

RB5: 312

2

DL_TFC2

UL_TFC2

DL_TFC0, DL_TFC9, UL_TFC0, UL_TFC9

UL_TFC0, UL_TFC1, UL_TFC2,

UL_TFC9,

UL_TFC11

RB5: 632

RB5: 632

3

DL_TFC3

UL_TFC3

DL_TFC0, DL_TFC9, UL_TFC0, UL_TFC9

UL_TFC0, UL_TFC1, UL_TFC3,

UL_TFC9,

UL_TFC12

RB5: 1272

RB5: 1272

4

DL_TFC4

UL_TFC4

DL_TFC0, DL_TFC9, UL_TFC0, UL_TFC9

UL_TFC0, UL_TFC1, UL_TFC4,

UL_TFC9,

UL_TFC13

RB5: 2552

RB5: 2552

5

DL_TFC5

UL_TFC5

DL_TFC0, DL_TFC9, UL_TFC0, UL_TFC9

UL_TFC0, UL_TFC1, UL_TFC5,

UL_TFC9,

UL_TFC14

RB5: 3832

RB5: 3832

6

DL_TFC6

UL_TFC6

DL_TFC0, DL_TFC9, UL_TFC0, UL_TFC9

UL_TFC0, UL_TFC1, UL_TFC6,

UL_TFC9,

UL_TFC15

RB5: 5112

RB5: 5112

7

DL_TFC7

UL_TFC7

DL_TFC0, DL_TFC9, UL_TFC0, UL_TFC9

UL_TFC0, UL_TFC1, UL_TFC7,

UL_TFC9,

UL_TFC16

RB5: 6392

RB5: 6392

8

DL_TFC8

UL_TFC8

DL_TFC0, DL_TFC9, UL_TFC0, UL_TFC9

UL_TFC0, UL_TFC1, UL_TFC8,

UL_TFC9,

UL_TFC17

RB5: 7672

RB5: 7672

NOTE 1: UL_TFC0, UL_TFC1, and UL_TFC9 are part of minimum set of TFCIs.

NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs.

See 18.3.1.1 for test procedure.

18.3.2.34.2.4 Test requirements

See 18.3.1.1 for definition of step 10 and step 15.

1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.

2. At step 15 the UE transmitted transport format shall be

– for sub-test 1: RB5/TF1 (1×336).

– for sub-test 2: RB5/TF2 (2×336).

– for sub-test 3: RB5/TF3 (4×336).

– for sub-test 4: RB5/TF4 (8×336).

– for sub-test 5: RB5/TF5 (12×336).

– for sub-test 6: RB5/TF6 (16×336).

– for sub-test 7: RB5/TF7 (20×336).

– for sub-test 8: RB5/TF8 (24×336).

3. At step 15 the UE shall return

– for sub-test 1 to 8: an RLC SDU on RB5 having the same content as the DL RLC SDU sent by the SS.

18.3.2.35 Interactive or background / UL:64 DL:2048 kbps / PS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH

18.3.2.35.1 Interactive or background / UL:64 DL:2048 kbps / PS RAB / Payload 320, 10 ms TTI Down Link, Physical Configuration 1

18.3.2.35.1.1 Conformance requirement

See 18.3.2.4.1.

18.3.2.35.1.2 Test purpose

Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.11.6.4.1.35 for the uplink payload 320, the downlink 10 ms TTI, and physical configuration 1 case.

18.3.2.35.1.3 Method of test

Uplink TFS:

TFI

RB5

(64 kbps)

DCCH

TFS

TF0, bits

0x336

0x148

TF1, bits

1×336

1×148

TF2, bits

2×336

N/A

TF3, bits

3×336

N/A

TF4, bits

4×336

N/A

Uplink TFCS:

TFCI

(RB5, DCCH)

UL_TFC0

(TF0, TF0)

UL_TFC1

(TF1, TF0)

UL_TFC2

(TF2, TF0)

UL_TFC3

(TF3, TF0)

UL_TFC4

(TF4, TF0)

UL_TFC5

(TF0, TF1)

UL_TFC6

(TF1, TF1)

UL_TFC7

(TF2, TF1)

UL_TFC8

(TF3, TF1)

UL_TFC9

(TF4, TF1)

Downlink TFS:

TFI

RB5

(2048 kbps, 10ms)

DCCH

TFS

TF0, bits

0x656

0x148

TF1, bits

1×656

1×148

TF2, bits

2×656

N/A

TF3, bits

4×656

N/A

TF4, bits

8×656

N/A

TF5, bits

12×656

N/A

TF6, bits

16×656

N/A

TF7, bits

20×656

N/A

TF8, bits

24×656

N/A

TF9, bits

28×656

N/A

TF10, bits

31×656

N/A

Downlink TFCS:

TFCI

(RB5, DCCH)

DL_TFC0

(TF0, TF0)

DL_TFC1

(TF1, TF0)

DL_TFC2

(TF2, TF0)

DL_TFC3

(TF3, TF0)

DL_TFC4

(TF4, TF0)

DL_TFC5

(TF5, TF0)

DL_TFC6

(TF6, TF0)

DL_TFC7

(TF7, TF0)

DL_TFC8

(TF8, TF0)

DL_TFC9

(TF9, TF0)

DL_TFC10

(TF10, TF0)

DL_TFC11

(TF0, TF1)

DL_TFC12

(TF1, TF1)

DL_TFC13

(TF2, TF1)

DL_TFC14

(TF3, TF1)

DL_TFC15

(TF4, TF1)

DL_TFC16

(TF5, TF1)

DL_TFC17

(TF6, TF1)

DL_TFC18

(TF7, TF1)

DL_TFC19

(TF8, TF1)

DL_TFC20

(TF9, TF1)

DL_TFC21

(TF10, TF1)

Physical channel parameters

DPCH Uplink

Physical Configuration 1

Midamble

256 chips

Codes and time slots

SF2 x 1 code x 3 time slots

Max. Number of data

bits/radio frame

6480 bits

TFCI code word

16 bits

TPC

2 bits

Puncturing Limit

0.48

Sub-tests:

Sub-test

Downlink TFCS

Under

Test

Uplink TFCS

Under test

Implicitly tested

Restricted UL TFCIs

(note 1)

UL RLC SDU size

(bits)

(note 2)

Test data size

(bits)

(note 2)

1

DL_TFC1

UL_TFC1

DL_TFC0, DL_TFC11, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,

UL_TFC5,

UL_TFC6

RB5: 632

RB5: 632

2

DL_TFC2

UL_TFC2

DL_TFC0, DL_TFC11, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,UL_TFC2,

UL_TFC5,

UL_TFC7

RB5: 1272

RB5: 1272

3

DL_TFC3

UL_TFC3

DL_TFC0, DL_TFC11, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,UL_TFC3,

UL_TFC5,

UL_TFC8

RB5: 2872

RB5: 2552

4

DL_TFC4

UL_TFC4

DL_TFC0, DL_TFC11, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,UL_TFC4,

UL_TFC5,

UL_TFC9

RB5: 5112

RB5: 5112

5

DL_TFC5

UL_TFC4

DL_TFC0, DL_TFC11, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,UL_TFC4,

UL_TFC5,

UL_TFC9

RB5: 7672

RB5: 7672

6

DL_TFC6

UL_TFC4

DL_TFC0, DL_TFC11, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,UL_TFC4,

UL_TFC5,

UL_TFC9

RB5: 10232

RB5: 10232

7

DL_TFC7

UL_TFC4

DL_TFC0, DL_TFC11, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,UL_TFC4,

UL_TFC5,

UL_TFC9

RB5: 12792

RB5: 12792

8

DL_TFC8

UL_TFC4

DL_TFC0, DL_TFC11, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,UL_TFC4,

UL_TFC5,

UL_TFC9

RB5: 15352

RB5: 15352

9

DL_TFC9

UL_TFC4

DL_TFC0, DL_TFC11, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,UL_TFC4,

UL_TFC5,

UL_TFC9

RB5: 17912

RB5: 17912

10

DL_TFC10

UL_TFC4

DL_TFC0, DL_TFC11, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,UL_TFC4,

UL_TFC5,

UL_TFC9

RB5: 20472

RB5: 20472

NOTE 1: UL_TFC0, UL_TFC1, and UL_TFC5 are part of minimum set of TFCIs.

NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs.
The UL RLC SDU size have been chosen such that the UE will return all data received in downlink and that the UL RLC SDU will fill up the uplink transport format set under test over one or several transmission time intervals.

See 18.3.1.1 for test procedure.

18.3.2.35.1.4 Test requirements

See 18.3.1.1 for definition of step 10 and step 15.

1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.

2. At step 15 the UE transmitted transport format shall be

– for sub-test 1: RB5/TF1 (1×336).

– for sub-test 2: RB5/TF2 (2×336).

– for sub-test 3: RB5/TF3 (3×336).

– for sub-test 4 to 10: RB5/TF4 (4×336).

3. At step 15 the UE shall return

– for sub-test 1, 2, and 4 to 10: an RLC SDU on RB5 having the same content as the DL RLC SDU sent by the SS.

– for sub-test 3: an RLC SDU on RB5 having the same content as 1 times plus 320 lsb’s of the DL RLC SDU sent by the SS.

18.3.2.35.2 Interactive or background / UL:64 DL:2048 kbps / PS RAB / Payload 128, 20 ms TTI Down Link, Physical Configuration 2

18.3.2.35.2.1 Conformance requirement

See 18.3.2.4.1.

18.3.2.35.2.2 Test purpose

Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.11.6.4.1.35 for the uplink payload 128, the downlink 20 ms TTI, and physical configuration 2 case.

18.3.2.35.2.3 Method of test

Uplink TFS:

TFI

RB5

(64 kbps)

DCCH

TFS

TF0, bits

0x144

0x148

TF1, bits

1×144

1×148

TF2, bits

3×144

N/A

TF3, bits

7×144

N/A

TF4, bits

10×144

N/A

Uplink TFCS:

TFCI

(RB5, DCCH)

UL_TFC0

(TF0, TF0)

UL_TFC1

(TF1, TF0)

UL_TFC2

(TF2, TF0)

UL_TFC3

(TF3, TF0)

UL_TFC4

(TF4, TF0)

UL_TFC5

(TF0, TF1)

UL_TFC6

(TF1, TF1)

UL_TFC7

(TF2, TF1)

UL_TFC8

(TF3, TF1)

UL_TFC9

(TF4, TF1)

Downlink TFS:

TFI

RB5

(2048 kbps, 10ms)

DCCH

TFS

TF0, bits

0x656

0x148

TF1, bits

1×656

1×148

TF2, bits

2×656

N/A

TF3, bits

4×656

N/A

TF4, bits

8×656

N/A

TF5, bits

12×656

N/A

TF6, bits

16×656

N/A

TF7, bits

20×656

N/A

TF8, bits

24×656

N/A

TF9, bits

28×656

N/A

TF10, bits

32×656

N/A

TF11, bits

36×656

N/A

TF12, bits

40×656

N/A

TF13, bits

44×656

N/A

TF14, bits

48×656

N/A

TF15, bits

52×656

N/A

TF16, bits

56×656

N/A

TF17, bits

60×656

N/A

TF18, bits

64×656

N/A

Downlink TFCS:

TFCI

(RB5, DCCH)

DL_TFC0

(TF0, TF0)

DL_TFC1

(TF1, TF0)

DL_TFC2

(TF2, TF0)

DL_TFC3

(TF3, TF0)

DL_TFC4

(TF4, TF0)

DL_TFC5

(TF5, TF0)

DL_TFC6

(TF6, TF0)

DL_TFC7

(TF7, TF0)

DL_TFC8

(TF8, TF0)

DL_TFC9

(TF9, TF0)

DL_TFC10

(TF10, TF0)

DL_TFC11

(TF11, TF0)

DL_TFC12

(TF12, TF0)

DL_TFC13

(TF13, TF0)

DL_TFC14

(TF14, TF0)

DL_TFC15

(TF15, TF0)

DL_TFC16

(TF16, TF0)

DL_TFC17

(TF17, TF0)

DL_TFC18

(TF18, TF0)

DL_TFC19

(TF0, TF1)

DL_TFC20

(TF1, TF1)

DL_TFC21

(TF2, TF1)

DL_TFC22

(TF3, TF1)

DL_TFC23

(TF4, TF1)

DL_TFC24

(TF5, TF1)

DL_TFC25

(TF6, TF1)

DL_TFC26

(TF7, TF1)

DL_TFC27

(TF8, TF1)

DL_TFC28

(TF9, TF1)

DL_TFC29

(TF10, TF1)

DL_TFC30

(TF11, TF1)

DL_TFC31

(TF12, TF1)

DL_TFC32

(TF13, TF1)

DL_TFC33

(TF14, TF1)

DL_TFC34

(TF15, TF1)

DL_TFC35

(TF16, TF1)

DL_TFC36

(TF17, TF1)

DL_TFC37

(TF18, TF1)

Physical channel parameters

DPCH Downlink

Physical Configuration 2

Midamble

256 chips

Codes and time slots

SF16 x 13 codes x 4 time slots + SF16 x 12 codes x 7 time slot

Max. Number of data bits/radio frame

37520 bits (alt. 37504)

TFCI code word

16 bits (alt. 32 bits)

Puncturing limit

0.56

Sub-tests:

Sub-test

Downlink TFCS

Under

Test

Uplink TFCS

Under test

Implicitly tested

Restricted UL TFCIs

(note 1)

UL RLC SDU size

(bits)

(note 2)

Test data size

(bits)

(note 2)

1

DL_TFC1

UL_TFC1

DL_TFC0, DL_TFC19, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,

UL_TFC5,

UL_TFC6

RB5: 632

RB5: 632

2

DL_TFC2

UL_TFC2

DL_TFC0, DL_TFC19, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,UL_TFC2,

UL_TFC5,

UL_TFC7

RB5: 1536

RB5: 1272

3

DL_TFC3

UL_TFC3

DL_TFC0, DL_TFC19, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,UL_TFC3,

UL_TFC5,

UL_TFC8

RB5: 2688

RB5: 2552

4

DL_TFC4

UL_TFC4

DL_TFC0, DL_TFC19, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,UL_TFC4,

UL_TFC5,

UL_TFC9

RB5: 5112

RB5: 5112

5

DL_TFC5

UL_TFC4

DL_TFC0, DL_TFC19, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,UL_TFC4,

UL_TFC5,

UL_TFC9

RB5: 7672

RB5: 7672

6

DL_TFC6

UL_TFC4

DL_TFC0, DL_TFC19, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,UL_TFC4,

UL_TFC5,

UL_TFC9

RB5: 10232

RB5: 10232

7

DL_TFC7

UL_TFC4

DL_TFC0, DL_TFC19, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,UL_TFC4,

UL_TFC5,

UL_TFC9

RB5: 12792

RB5: 12792

8

DL_TFC8

UL_TFC4

DL_TFC0, DL_TFC19, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,UL_TFC4,

UL_TFC5,

UL_TFC9

RB5: 15352

RB5: 15352

9

DL_TFC9

UL_TFC4

DL_TFC0, DL_TFC19, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,UL_TFC4,

UL_TFC5,

UL_TFC9

RB5: 17912

RB5: 17912

10

DL_TFC10

UL_TFC4

DL_TFC0, DL_TFC19, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,UL_TFC4,

UL_TFC5,

UL_TFC9

RB5: 20472

RB5: 20472

11

DL_TFC11

UL_TFC4

DL_TFC0, DL_TFC19, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,UL_TFC4,

UL_TFC5,

UL_TFC9

RB5: 23032

RB5: 23032

12

DL_TFC12

UL_TFC4

DL_TFC0, DL_TFC19, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,UL_TFC4,

UL_TFC5,

UL_TFC9

RB5: 25592

RB5: 25592

13

DL_TFC13

UL_TFC4

DL_TFC0, DL_TFC19, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,UL_TFC4

UL_TFC5,

UL_TFC9

RB5: 28152

RB5: 28152

14

DL_TFC14

UL_TFC4

DL_TFC0, DL_TFC19, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,UL_TFC4,

UL_TFC5,

UL_TFC9

RB5: 30712

RB5: 30712

15

DL_TFC15

UL_TFC4

DL_TFC0, DL_TFC19, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,UL_TFC4,

UL_TFC5,

UL_TFC9

RB5: 33272

RB5: 33272

16

DL_TFC16

UL_TFC4

DL_TFC0, DL_TFC19, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,UL_TFC4,

UL_TFC5,

UL_TFC9

RB5: 35832

RB5: 35832

17

DL_TFC17

UL_TFC4

DL_TFC0, DL_TFC19, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,UL_TFC4

UL_TFC5,

UL_TFC9

RB5: 38392

RB5: 38392

18

DL_TFC18

UL_TFC4

DL_TFC0, DL_TFC19, UL_TFC0, UL_TFC5

UL_TFC0, UL_TFC1,UL_TFC4,

UL_TFC5,

UL_TFC9

RB5: 40952

RB5: 40952

NOTE 1: UL_TFC0, UL_TFC1, and UL_TFC5 are part of minimum set of TFCIs.

NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs.
The UL RLC SDU size have been chosen such that the UE will return all data received in downlink and that the UL RLC SDU will fill up the uplink transport format set under test over one or several transmission time intervals.

See 18.3.1.1 for test procedure.

18.3.2.35.2.4 Test requirements

See 18.3.1.1 for definition of step 10 and step 15.

1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.

2. At step 15 the UE transmitted transport format shall be

– for sub-test 1: RB5/TF1 (1×144).

– for sub-test 2: RB5/TF2 (3×144).

– for sub-test 3: RB5/TF3 (7×144).

– for sub-test 4 to 18: RB5/TF4 (10×144).

3. At step 15 the UE shall return

– for sub-test 1, and 4 to 18: an RLC SDU on RB5 having the same content as the DL RLC SDU sent by the SS.

– for sub-test 2: an RLC SDU on RB5 having the same content as 1 times plus 264 lsb’s of the DL RLC SDU sent by the SS.

– for sub-test 3: an RLC SDU on RB5 having the same content as 1 times plus 136 lsb’s of the DL RLC SDU sent by the SS.

18.3.2.36 Void

18.3.2.37 Void