18.2.5a Combinations on SCCPCH type 2
34.123-13GPPPart 1: Protocol conformance specificationRelease 15TSUser Equipment (UE) conformance specification
18.2.5a.1 124.4kbps RB for MBSFN MTCH with 80 ms TTI
18.2.5a.1.1 Conformance Requirement
The UE shall correctly receive user data on the MTCH from the peer to peer RLC entity according to the configured MTCH.
Reference(s)
3GPP TS 25.2xx series (Physical Layer)
3GPP TS 25.321 (MAC)
3GPP TS 25.322 (RLC)
3GPP TS 25.331 (RRC)
18.2.5a.1.2 Test purpose
Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.11.7.2.2.1.
18.2.5a.1.3 Method of Test
See subclause 18.2.1.6 for test procedure.
Downlink TFS:
TFI |
RB for MTCH (124.4 kbps) |
|
TFS |
TF0, bits |
0x4992 |
TF1, bits |
1×4992 |
|
TF2, bits |
2×4992 |
Downlink TFCS:
TFCI |
RB for MTCH (124.4 kbps) |
DL_TFC0 |
(TF0) |
DL_TFC1 |
(TF1) |
DL_TFC2 |
(TF2) |
Sub-tests:
Sub-test |
Downlink TFCS Under test |
Implicitly tested |
Test data size (bits) (note 1) |
1 |
DL_TFC1 |
DL_TFC0 |
4960 |
2 |
DL_TFC2 |
DL_TFC0 |
9936 |
NOTE 1: Test data size (=DL SDU size) has been set to the N*payload size of the DL TF under test minus 16 bits (size of 15 bit length indicator and expansion bit), where N is the number of transport blocks in the transport format combination under test. |
18.2.5a.1.4 Test Requirements
See subclause 18.2.1.6 for definition of steps 9 and 13.
1. For the first sub-test: At step 9 the UE shall send a UE TEST LOOP MODE 3 RLC SDU COUNTER RESPONSE with a RLC SDU counter value greater than zero.
2. For the second and following sub-tests: At step 13 the UE shall send a UE TEST LOOP MODE 3 RLC SDU COUNTER RESPONSE with a RLC SDU counter value greater than the reported value at previous sub-test.
NOTE: For UE in UE test loop mode 3 then the RLC SDU counter value is only reset upon reception of CLOSE UE TEST LOOP message configuring UE test loop mode 3. As the generic test procedure in section 18.2.1.6 runs through all sub-tests without deactivating the UE test mode then the SS needs to check the reported counter value against the value reported at the previous sub-test.
18.2.5a.2 320.4kbps RB for MBSFN MTCH with 80 ms TTI
18.2.5a.2.1 Conformance Requirement
See 18.2.5a.1.1.
18.2.5a.2.2 Test purpose
Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.11.7.2.2.2.
18.2.5a.2.3 Method of Test
See subclause 18.2.1.6 for test procedure.
Downlink TFS:
TFI |
RB for MTCH (320.4 kbps) |
|
TFS |
TF0, bits |
0x4288 |
TF1, bits |
1×4288 |
|
TF2, bits |
2×4288 |
|
TF3, bits |
3×4288 |
|
TF4, bits |
4×4288 |
|
TF5, bits |
5×4288 |
|
TF6, bits |
6×4288 |
Downlink TFCS:
TFCI |
RB for MTCH (320.4 kbps) |
DL_TFC0 |
(TF0) |
DL_TFC1 |
(TF1) |
DL_TFC2 |
(TF2) |
DL_TFC3 |
(TF3) |
DL_TFC4 |
(TF4) |
DL_TFC5 |
(TF5) |
DL_TFC6 |
(TF6) |
Sub-tests:
Sub-test |
Downlink TFCS Under test |
Implicitly tested |
Test data size (bits) (note 1) |
1 |
DL_TFC1 |
DL_TFC0 |
4256 |
2 |
DL_TFC2 |
DL_TFC0 |
|
3 |
DL_TFC3 |
DL_TFC0 |
|
4 |
DL_TFC4 |
DL_TFC0 |
|
5 |
DL_TFC5 |
DL_TFC0 |
|
6 |
DL_TFC6 |
DL_TFC0 |
25616 |
NOTE 1: Test data size (=DL SDU size) has been set to the N*payload size of the DL TF under test minus 16 bits (size of 15 bit length indicator and expansion bit), where N is the number of transport blocks in the transport format combination under test. |
18.2.5a.2.4 Test Requirements
See subclause 18.2.1.6 for definition of steps 9 and 13.
1. For the first sub-test: At step 9 the UE shall send a UE TEST LOOP MODE 3 RLC SDU COUNTER RESPONSE with a RLC SDU counter value greater than zero.
2. For the second and following sub-tests: At step 13 the UE shall send a UE TEST LOOP MODE 3 RLC SDU COUNTER RESPONSE with a RLC SDU counter value greater than the reported value at previous sub-test.
NOTE For UE in UE test loop mode 3 then the RLC SDU counter value is only reset upon reception of CLOSE UE TEST LOOP message configuring UE test loop mode 3. As the generic test procedure in section 18.2.1.6 runs through all sub-tests without deactivating the UE test mode then the SS needs to check the reported counter value against the value reported at the previous sub-test.
18.2.5a.3 497.6kbps RB for MBSFN MTCH with 80 ms TTI
18.2.5a.3.1 Conformance Requirement
See 18.2.5a.1.1
18.2.5a.3.2 Test purpose
Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.11.7.2.2.3.
18.2.5a.3.3 Method of Test
See subclause 18.2.1.6 for test procedure.
Downlink TFS:
TFI |
RB for MTCH (497.6 kbps) |
|
TFS |
TF0, bits |
0x4992 |
TF1, bits |
1×4992 |
|
TF2, bits |
2×4992 |
|
TF3, bits |
3×4992 |
|
TF4, bits |
4×4992 |
|
TF5, bits |
5×4992 |
|
TF6, bits |
6×4992 |
|
TF7, bits |
7×4992 |
|
TF8, bits |
8×4992 |
Downlink TFCS:
TFCI |
RB for MTCH (497.6 kbps) |
DL_TFC0 |
(TF0) |
DL_TFC1 |
(TF1) |
DL_TFC2 |
(TF2) |
DL_TFC3 |
(TF3) |
DL_TFC4 |
(TF4) |
DL_TFC5 |
(TF5) |
DL_TFC6 |
(TF6) |
DL_TFC7 |
(TF7) |
DL_TFC8 |
(TF8) |
Sub-tests:
Sub-test |
Downlink TFCS Under test |
Implicitly tested |
Test data size (bits) (note 1) |
1 |
DL_TFC1 |
DL_TFC0 |
4960 |
2 |
DL_TFC2 |
DL_TFC0 |
|
3 |
DL_TFC3 |
DL_TFC0 |
|
4 |
DL_TFC4 |
DL_TFC0 |
|
5 |
DL_TFC5 |
DL_TFC0 |
|
6 |
DL_TFC6 |
DL_TFC0 |
|
7 |
DL_TFC7 |
DL_TFC0 |
|
8 |
DL_TFC8 |
DL_TFC0 |
39792 |
NOTE 1: Test data size (=DL SDU size) has been set to the N*payload size of the DL TF under test minus 16 bits (size of 15 bit length indicator and expansion bit), where N is the number of transport blocks in the transport format combination under test. |
18.2.5a.3.4 Test Requirements
See subclause 18.2.1.6 for definition of steps 9 and 13.
1. For the first sub-test: At step 9 the UE shall send a UE TEST LOOP MODE 3 RLC SDU COUNTER RESPONSE with a RLC SDU counter value greater than zero.
2. For the second and following sub-tests: At step 13 the UE shall send a UE TEST LOOP MODE 3 RLC SDU COUNTER RESPONSE with a RLC SDU counter value greater than the reported value at previous sub-test.
NOTE: For UE in UE test loop mode 3 then the RLC SDU counter value is only reset upon reception of CLOSE UE TEST LOOP message configuring UE test loop mode 3. As the generic test procedure in section 18.2.1.6 runs through all sub-tests without deactivating the UE test mode then the SS needs to check the reported counter value against the value reported at the previous sub-test.