18.2.2 Combinations on DPCH
34.123-13GPPPart 1: Protocol conformance specificationRelease 15TSUser Equipment (UE) conformance specification
18.2.2.1 Stand-alone UL:1.7 DL:1.7 kbps SRBs for DCCH
Test to verify establishment and signalling of stand-alone signalling reference radio bearer configuration as specified in TS 34.108, clause 6.10.3.4.1.1.
The test case is performed by running test case 9.4.1 (Location updating / accepted) using the stand-alone signalling reference radio bearer configuration as specified in TS 34.108, clause 6.10.3.4.1.1.
18.2.2.1a Stand-alone UL:1.7 DL:1.7 kbps SRBs for DCCH (multiframe)
Test to verify establishment and signalling of stand-alone signalling reference radio bearer configuration as specified in TS 34.108, clause 6.10.3.4.1.1a.
The test case is performed by running test case 9.4.1 (Location updating / accepted) using the stand-alone signalling reference radio bearer configuration as specified in TS 34.108, clause 6.10.3.4.1.1a.
18.2.2.2 Stand-alone UL:3.4 DL:3.4 kbps SRBs for DCCH
Test to verify establishment and signalling of stand-alone signalling reference radio bearer configuration as specified in TS 34.108, clause 6.10.3.4.1.2.
The test case is performed by running test case 9.4.1 (Location updating / accepted) using the stand-alone signalling reference radio bearer configuration as specified in TS 34.108, clause 6.10.3.4.1.2.
18.2.2.3 Stand-alone UL:13.6 DL:13.6 kbps SRBs for DCCH
Implicitly tested.
NOTE The stand-alone UL:13.6 DL:13.6 kbps SRBs for DCCH in TS 34.108, clause 6.10.3.4.1.3 is the default signalling radio bearer used in the generic setup procedure as specified in TS 34.108 clause 7.
18.2.2.4 Conversational / speech / UL:12.2 DL:12.2 kbps / CS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH
18.2.2.4.1 Conformance requirement
The UE shall be able to establish the UTRAN requested radio bearers within the UE’s signalled radio access capabilities.
The UE shall correctly transfer user data from peer to peer RLC entities according to the requested radio bearer configuration.
Reference(s)
3GPP TS 25.331, clause 8.2.1
3GPP TS 25.2xx series (Physical Layer)
3GPP TS 25.321 (MAC)
3GPP TS 25.322 (RLC)
18.2.2.4.2 Test purpose
To verify radio bearer establishment and correct data transfer for reference radio bearer configuration as specified in TS 34.108, clause 6.10.3.4.1.4.
18.2.2.4.3 Method of test
Uplink TFS:
TFI |
RB5 (RAB subflow #1) |
RB6 (RAB subflow #2) |
RB7 (RAB subflow #3) |
DCCH |
|
TFS |
TF0, bits |
0x81(alt. 1×0) |
0x103 |
0x60 |
0x148 |
TF1, bits |
1×39 |
1×103 |
1×60 |
1×148 |
|
TF2, bits |
1×81 |
N/A |
N/A |
N/A |
Uplink TFCS:
TFCI |
(RB5, RB6, RB7, DCCH) |
UL_TFC0 |
(TF0, TF0, TF0, TF0) |
UL_TFC1 |
(TF1, TF0, TF0, TF0) |
UL_TFC2 |
(TF2, TF1, TF1, TF0) |
UL_TFC3 |
(TF0, TF0, TF0, TF1) |
UL_TFC4 |
(TF1, TF0, TF0, TF1) |
UL_TFC5 |
(TF2, TF1, TF1, TF1) |
Downlink TFS:
RB5 (RAB subflow #1) |
RB6 (RAB subflow #2) |
RB7 (RAB subflow #3) |
DCCH |
||
TFS |
TF0, bits |
0x81(alt. 1×0) |
0x103 |
0x60 |
0x148 |
TF1, bits |
1×39 |
1×103 |
1×60 |
1×148 |
|
TF2, bits |
1×81 |
N/A |
N/A |
N/A |
Downlink TFCS:
TFCI |
(RB5, RB6, RB7, DCCH) |
DL_TFC0 |
(TF0, TF0, TF0, TF0) |
DL_TFC1 |
(TF1, TF0, TF0, TF0) |
DL_TFC2 |
(TF2, TF1, TF1, TF0) |
DL_TFC3 |
(TF0, TF0, TF0, TF1) |
DL_TFC4 |
(TF1, TF0, TF0, TF1) |
DL_TFC5 |
(TF2, TF1, TF1, TF1) |
Sub-tests:
Sub-test |
Downlink TFCS under test |
Uplink TFCS Under test |
Implicitly tested |
Restricted UL TFCIs (note 1) |
UL RLC SDU size (note 2) |
Test data size (note 2) |
1 |
DL_TFC1 |
UL_TFC1 |
DL_TFC0, DL_TFC3, UL_TFC0, UL_TFC3 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3, UL_TFC4 |
RB5: 39 bits RB6: 103 bits RB7: 60 bits |
RB5: 39 bits RB6: No data RB7: No data |
2 |
DL_TFC2 |
UL_TFC2 |
DL_TFC0, DL_TFC3, UL_TFC0, UL_TFC3 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3, UL_TFC5 |
RB5: 81 bits RB6: 103 bits RB7: 60 bits |
RB5: 81 bits RB6: 103 bits RB7: 60 bits |
NOTE 1: UL_TFC0, UL_TFC1, UL_TFC2 and UL_TFC3 are part of minimum set of TFCIs. NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs. |
See 18.2.1.1 for test procedure.
18.2.2.4.4 Test requirements
See 18.2.1.1 for definition of step 10 and step 15.
1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.
2. At step 15 the UE transmitted transport format shall be
– for sub-test 1: RB5/TF1 (1×39).
– for sub-test 2: RB5/TF2 (1×81); RB6/TF1 (1×103); and RB7/TF1 (1×60).
3. At step 15 the UE shall return
– for sub-test 1: an RLC SDU on RB5 having the same content as sent by SS; and no data shall be received on RB6 or RB7.
– for sub-test 2: an RLC SDU on each of RB5, RB6 and RB7 having the same content as sent by SS
18.2.2.4a Conversational / speech / UL:(12.2 7.95 5.9 4.75) DL:(12.2 7.95 5.9 4.75) kbps / CS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH.
18.2.2.4a.1 Conformance requirement
See clause 18.2.2.4.1.
18.2.2.4a.2 Test purpose
Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.10.3.4.1.4a.
18.2.2.4a.3 Method of test
Uplink TFS:
TFI |
RB5 (RAB subflow #1) |
RB6 (RAB subflow #2) |
RB7 (RAB subflow #3) |
DCCH |
|
TFS |
TF0, bits |
0x81(alt. 1×0) |
0x103 |
0x60 |
0x148 |
TF1, bits |
1×39 |
1×53 |
1×60 |
1×148 |
|
TF2, bits |
1×42 |
1×63 |
N/A |
N/A |
|
TF3, bits |
1×55 |
1×84 |
N/A |
N/A |
|
TF4, bits |
1×75 |
1×103 |
N/A |
N/A |
|
TF5, bits |
1×81 |
N/A |
N/A |
N/A |
Uplink TFCS:
TFCI |
(RB5, RB6, RB7,DCCH) |
UL_TFC0 |
(TF0, TF0, TF0, TF0) |
UL_TFC1 |
(TF1, TF0, TF0, TF0) |
UL_TFC2 |
(TF2, TF1, TF0, TF0) |
UL_TFC3 |
(TF3, TF2, TF0, TF0) |
UL_TFC4 |
(TF4, TF3, TF0, TF0) |
UL_TFC5 |
(TF5, TF4, TF1, TF0) |
UL_TFC6 |
(TF0, TF0, TF0, TF1) |
UL_TFC7 |
(TF1, TF0, TF0, TF1) |
UL_TFC8 |
(TF2, TF1, TF0, TF1) |
UL_TFC9 |
(TF3, TF2, TF0, TF1) |
UL_TFC10 |
(TF4, TF3, TF0, TF1) |
UL_TFC11 |
(TF5, TF4, TF1, TF1) |
Downlink TFS:
RB5 (RAB subflow #1) |
RB6 (RAB subflow #2) |
RB7 (RAB subflow #3) |
DCCH |
||
TFS |
TF0, bits |
0x81(alt. 1×0) |
0x103 |
0x60 |
0x148 |
TF1, bits |
1×39 |
1×53 |
1×60 |
1×148 |
|
TF2, bits |
1×42 |
1×63 |
N/A |
N/A |
|
TF3, bits |
1×55 |
1×84 |
N/A |
N/A |
|
TF4, bits |
1×75 |
1×103 |
N/A |
N/A |
|
TF5, bits |
1×81 |
N/A |
N/A |
N/A |
Downlink TFCS:
TFCI |
(RB5, RB6, RB7, DCCH) |
DL_TFC0 |
(TF0, TF0, TF0, TF0) |
DL_TFC1 |
(TF1, TF0, TF0, TF0) |
DL_TFC2 |
(TF2, TF1, TF0, TF0) |
DL_TFC3 |
(TF3, TF2, TF0, TF0) |
DL_TFC4 |
(TF4, TF3, TF0, TF0) |
DL_TFC5 |
(TF5, TF4, TF1, TF0) |
DL_TFC6 |
(TF0, TF0, TF0, TF1) |
DL_TFC7 |
(TF1, TF0, TF0, TF1) |
DL_TFC8 |
(TF2, TF1, TF0, TF1) |
DL_TFC9 |
(TF3, TF2, TF0, TF1) |
DL_TFC10 |
(TF4, TF3, TF0, TF1) |
DL_TFC11 |
(TF5, TF4, TF1, TF1) |
Sub-tests:
Sub-test |
Downlink TFCS under test |
Uplink TFCS Under test |
Implicitly tested |
Restricted UL TFCIs (note 1) |
UL RLC SDU size (note 2) |
Test data size (note 2) |
1 |
DL_TFC1 |
UL_TFC1 |
DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3, UL_TFC4, UL_TFC5, UL_TFC6, UL_TFC7 |
RB5: 39 bits RB6: 103 bits RB7: 60 bits |
RB5: 39 bits RB6: No data RB7: No data |
2 |
DL_TFC2 |
UL_TFC2 |
DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3, UL_TFC4, UL_TFC5, UL_TFC6, UL_TFC8 |
RB5: 42 bits RB6: 53 bits RB7: 60 bits |
RB5: 42 bits RB6: 53 bits RB7: No data |
3 |
DL_TFC3 |
UL_TFC3 |
DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3, UL_TFC4, UL_TFC5, UL_TFC6, UL_TFC9 |
RB5: 55 bits RB6: 63 bits RB7: 60 bits |
RB5: 55 bits RB6: 63 bits RB7: No data |
4 |
DL_TFC4 |
UL_TFC4 |
DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3, UL_TFC4, UL_TFC5, UL_TFC6, UL_TFC10 |
RB5: 75 bits RB6: 84 bits RB7: 60 bits |
RB5: 75 bits RB6: 84 bits RB7: No data |
5 |
DL_TFC5 |
UL_TFC5 |
DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3, UL_TFC4, UL_TFC5, UL_TFC6, UL_TFC11 |
RB5: 81 bits RB6: 103 bits RB7: 60 bits |
RB5: 81 bits RB6: 103 bits RB7: 60 bits |
NOTE 1: UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3, UL_TFC4, UL_TFC5 and UL_TFC6 are part of minimum set of TFCIs. NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs. |
See clause 18.2.1.1 for test procedure.
18.2.2.4a.4 Test requirements
See 18.2.1.1 for definition of step 10 and step 15.
1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.
2. At step 15 the UE transmitted transport format shall be
– for sub-test 1: RB5/TF1 (1×39).
– for sub-test 2: RB5/TF2 (1×42) and RB6/TF1 (1×53)
– for sub-test 3: RB5/TF3 (1×55) and RB6/TF2 (1×63)
– for sub-test 4: RB5/TF4 (1×75) and RB6/TF3 (1×84)
– for sub-test 5: RB5/TF5 (1×81), RB6/TF4 (1×103) and RB7/TF1 (1×60)
3. At step 15 the UE shall return
– for sub-test 1: an RLC SDU on RB5 having the same content as sent by SS; and no data shall be received on RB6 or RB7.
– for sub-test 2,3 and 4: an RLC SDU on RB5 and RB6 having the same content as sent by SS; and no data shall be received on RB7.
– for sub-test 5: an RLC SDU on each of RB5, RB6 and RB7 having the same content as sent by SS.
18.2.2.5 Conversational / speech / UL:10.2 DL:10.2 kbps / CS RAB + UL:3.4 DL: 3.4 kbps SRBs for DCCH
18.2.2.5.1 Conformance requirement
See clause 18.2.2.4.1.
18.2.2.5.2 Test purpose
To verify radio bearer establishment and correct data transfer for reference radio bearer configuration as specified in TS 34.108, clause 6.10.3.4.1.5.
18.2.2.5.3 Method of test
Uplink TFS:
TFI |
RB5 (RAB subflow #1) |
RB6 (RAB subflow #2) |
RB7 (RAB subflow #3) |
DCCH |
|
TFS |
TF0, bits |
0x65(alt. 1×0) |
0x99 |
0x40 |
0x148 |
TF1, bits |
1×39 |
1×99 |
1×40 |
1×148 |
|
TF2, bits |
1×65 |
N/A |
N/A |
N/A |
Uplink TFCS:
TFCI |
(RB5, RB6, RB7,DCCH) |
UL_TFC0 |
(TF0, TF0, TF0, TF0) |
UL_TFC1 |
(TF1, TF0, TF0, TF0) |
UL_TFC2 |
(TF2, TF1, TF1, TF0) |
UL_TFC3 |
(TF0, TF0, TF0, TF1) |
UL_TFC4 |
(TF1, TF0, TF0, TF1) |
UL_TFC5 |
(TF2, TF1, TF1, TF1) |
Downlink TFS:
RB5 (RAB subflow #1) |
RB6 (RAB subflow #2) |
RB7 (RAB subflow #3) |
DCCH |
||
TFS |
TF0, bits |
0x65(alt. 1×0) |
0x99 |
0x40 |
0x148 |
TF1, bits |
1×39 |
1×99 |
1×40 |
1×148 |
|
TF2, bits |
1×65 |
N/A |
N/A |
N/A |
Downlink TFCS:
TFCI |
(RB5, RB6, RB7, DCCH) |
DL_TFC0 |
(TF0, TF0, TF0, TF0) |
DL_TFC1 |
(TF1, TF0, TF0, TF0) |
DL_TFC2 |
(TF2, TF1, TF1, TF0) |
DL_TFC3 |
(TF0, TF0, TF0, TF1) |
DL_TFC4 |
(TF1, TF0, TF0, TF1) |
DL_TFC5 |
(TF2, TF1, TF1, TF1) |
Sub-tests:
Sub-test |
Downlink TFCS under test |
Uplink TFCS Under test |
Implicitly tested |
Restricted UL TFCIs (note 1) |
UL RLC SDU size (note 2) |
Test data size (note 2) |
1 |
DL_TFC1 |
UL_TFC1 |
DL_TFC0, DL_TFC3, UL_TFC0, UL_TFC3 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3, UL_TFC4 |
RB5: 39 bits RB6: 99 bits RB7: 40 bits |
RB5: 39 bits RB6: No data RB7: No data |
2 |
DL_TFC2 |
UL_TFC2 |
DL_TFC0, DL_TFC3, UL_TFC0, UL_TFC3 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3, UL_TFC5 |
RB5: 65 bits RB6: 99 bits RB7: 40 bits |
RB5: 65 bits RB6: 99 bits RB7: 40 bits |
NOTE 1: UL_TFC0, UL_TFC1, UL_TFC2 and UL_TFC3 are part of minimum set of TFCIs. NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs. |
See clause 18.2.1.1 for test procedure.
18.2.2.5.4 Test requirements
See 18.2.1.1 for definition of step 10 and step 15.
1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.
2. At step 15 the UE transmitted transport format shall be
– for sub-test 1: RB5/TF1 (1×39).
– for sub-test 2: RB5/TF2 (1×65); RB6/TF1 (1×99); and RB7/TF1 (1×40).
3. At step 15 the UE shall return
– for sub-test 1: an RLC SDU on RB5 having the same content as sent by SS; and no data shall be received on RB6 or RB7.
– for sub-test 2: an RLC SDU on each of RB5, RB6 and RB7 having the same content as sent by SS.
18.2.2.5a Conversational / speech / UL:(10.2, 6.7, 5.9, 4.75) DL:(10.2, 6.7, 5.9, 4.75) kbps / CS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH.
18.2.2.5a.1 Conformance requirement
See clause 18.2.2.4.1.
18.2.2.5a.2 Test purpose
To verify radio bearer establishment and correct data transfer for reference radio bearer configuration as specified in TS 34.108, clause 6.10.3.4.1.5a.
18.2.2.5a.3 Method of test
Uplink TFS:
TFI |
RB5 (RAB subflow #1) |
RB6 (RAB subflow #2) |
RB7 (RAB subflow #3) |
DCCH |
|
TFS |
TF0, bits |
0x65(alt. 1×0) |
0x99 |
0x40 |
0x148 |
TF1, bits |
1×39 |
1×53 |
1×40 |
1×148 |
|
TF2, bits |
1×42 |
1×63 |
N/A |
N/A |
|
TF3, bits |
1×55 |
1×76 |
N/A |
N/A |
|
TF4, bits |
1×58 |
1×99 |
N/A |
N/A |
|
TF5, bits |
1×65 |
N/A |
N/A |
N/A |
Uplink TFCS:
TFCI |
(RB5, RB6, RB7,DCCH) |
UL_TFC0 |
(TF0, TF0, TF0, TF0) |
UL_TFC1 |
(TF1, TF0, TF0, TF0) |
UL_TFC2 |
(TF2, TF1, TF0, TF0) |
UL_TFC3 |
(TF3, TF2, TF0, TF0) |
UL_TFC4 |
(TF4, TF3, TF0, TF0) |
UL_TFC5 |
(TF5, TF4, TF1, TF0) |
UL_TFC6 |
(TF0, TF0, TF0, TF1) |
UL_TFC7 |
(TF1, TF0, TF0, TF1) |
UL_TFC8 |
(TF2, TF1, TF0, TF1) |
UL_TFC9 |
(TF3, TF2, TF0, TF1) |
UL_TFC10 |
(TF4, TF3, TF0, TF1) |
UL_TFC11 |
(TF5, TF4, TF1, TF1) |
Downlink TFS:
RB5 (RAB subflow #1) |
RB6 (RAB subflow #2) |
RB7 (RAB subflow #3) |
DCCH |
||
TFS |
TF0, bits |
0x65(alt. 1×0) |
0x99 |
0x40 |
0x148 |
TF1, bits |
1×39 |
1×53 |
1×40 |
1×148 |
|
TF2, bits |
1×42 |
1×63 |
N/A |
N/A |
|
TF3, bits |
1×55 |
1×76 |
N/A |
N/A |
|
TF4, bits |
1×58 |
1×99 |
N/A |
N/A |
|
TF5, bits |
1×65 |
N/A |
N/A |
N/A |
Downlink TFCS:
TFCI |
(RB5, RB6, RB7, DCCH) |
DL_TFC0 |
(TF0, TF0, TF0, TF0) |
DL_TFC1 |
(TF1, TF0, TF0, TF0) |
DL_TFC2 |
(TF2, TF1, TF0, TF0) |
DL_TFC3 |
(TF3, TF2, TF0, TF0) |
DL_TFC4 |
(TF4, TF3, TF0, TF0) |
DL_TFC5 |
(TF5, TF4, TF1, TF0) |
DL_TFC6 |
(TF0, TF0, TF0, TF1) |
DL_TFC7 |
(TF1, TF0, TF0, TF1) |
DL_TFC8 |
(TF2, TF1, TF0, TF1) |
DL_TFC9 |
(TF3, TF2, TF0, TF1) |
DL_TFC10 |
(TF4, TF3, TF0, TF1) |
DL_TFC11 |
(TF5, TF4, TF1, TF1) |
Sub-tests:
Sub-test |
Downlink TFCS under test |
Uplink TFCS Under test |
Implicitly tested |
Restricted UL TFCIs (note 1) |
UL RLC SDU size (note 2) |
Test data size (note 2) |
1 |
DL_TFC1 |
UL_TFC1 |
DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3, UL_TFC4, UL_TFC5, UL_TFC6, UL_TFC7 |
RB5: 39 bits RB6: 99 bits RB7: 40 bits |
RB5: 39 bits RB6: No data RB7: No data |
2 |
DL_TFC2 |
UL_TFC2 |
DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3, UL_TFC4, UL_TFC5, UL_TFC6, UL_TFC8 |
RB5: 42 bits RB6: 53 bits RB7: 40 bits |
RB5: 42 bits RB6: 53 bits RB7: No data |
3 |
DL_TFC3 |
UL_TFC3 |
DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3, UL_TFC4, UL_TFC5, UL_TFC6, UL_TFC9 |
RB5: 55 bits RB6: 63 bits RB7: 40 bits |
RB5: 55 bits RB6: 63 bits RB7: No data |
4 |
DL_TFC4 |
UL_TFC4 |
DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3, UL_TFC4, UL_TFC5, UL_TFC6, UL_TFC10 |
RB5: 58 bits RB6: 76 bits RB7: 40 bits |
RB5: 58 bits RB6: 76 bits RB7: No data |
5 |
DL_TFC5 |
UL_TFC5 |
DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3, UL_TFC4, UL_TFC5, UL_TFC6, UL_TFC11 |
RB5: 65 bits RB6: 99 bits RB7: 40 bits |
RB5: 65 bits RB6: 99 bits RB7: 40 bits |
NOTE 1: UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3, UL_TFC4, UL_TFC5 and UL_TFC6 are part of minimum set of TFCIs. NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs. |
See clause 18.2.1.1 for test procedure.
18.2.2.5a.4 Test requirements
See 18.2.1.1 for definition of step 10 and step 15.
1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.
2. At step 15 the UE transmitted transport format shall be
– for sub-test 1: RB5/TF1 (1×39).
– for sub-test 2: RB5/TF2 (1×42) and RB6/TF1 (1×53)
– for sub-test 3: RB5/TF3 (1×55) and RB6/TF2 (1×63)
– for sub-test 4: RB5/TF4 (1×58) and RB6/TF3 (1×76)
– for sub-test 5: RB5/TF5 (1×65), RB6/TF4 (1×99) and RB7/TF1 (1×40)
3. At step 15 the UE shall return
– for sub-test 1: an RLC SDU on RB5 having the same content as sent by the SS; and no data shall be received on RB6 or RB7.
– for sub-test 2, 3 and 4: an RLC SDU on RB5 and RB6 having the same content as sent by the SS; and no data shall be received on RB7.
– for sub-test 5: an RLC SDU on each of RB5, RB6 and RB7 having the same content as sent by the SS.
18.2.2.6 Conversational / speech / UL:7.95 DL:7.95 kbps / CS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH
18.2.2.6.1 Conformance requirement
See clause 18.2.2.4.1.
18.2.2.6.2 Test purpose
To verify radio bearer establishment and correct data transfer for reference radio bearer configuration as specified in TS 34.108, clause 6.10.3.4.1.6.
18.2.2.6.3 Method of test
Uplink TFS:
TFI |
RB5 (RAB subflow #1) |
RB6 (RAB subflow #2) |
DCCH |
|
TFS |
TF0, bits |
0x75(alt. 1×0) |
0x84 |
0x148 |
TF1, bits |
1×39 |
1×84 |
1×148 |
|
TF2, bits |
1×75 |
N/A |
N/A |
Uplink TFCS:
TFCI |
(RB5, RB6, DCCH) |
UL_TFC0 |
(TF0, TF0, TF0) |
UL_TFC1 |
(TF1, TF0, TF0) |
UL_TFC2 |
(TF2, TF1, TF0) |
UL_TFC3 |
(TF0, TF0, TF1) |
UL_TFC4 |
(TF1, TF0, TF1) |
UL_TFC5 |
(TF2, TF1, TF1) |
Downlink TFS:
RB5 (RAB subflow #1) |
RB6 (RAB subflow #2) |
DCCH |
||
TFS |
TF0, bits |
0x75(alt. 1×0) |
0x84 |
0x148 |
TF1, bits |
1×39 |
1×84 |
1×148 |
|
TF2, bits |
1×75 |
N/A |
N/A |
Downlink TFCS:
TFCI |
(RB5, RB6, DCCH) |
DL_TFC0 |
(TF0, TF0, TF0) |
DL_TFC1 |
(TF1, TF0, TF0) |
DL_TFC2 |
(TF2, TF1, TF0) |
DL_TFC3 |
(TF0, TF0, TF1) |
DL_TFC4 |
(TF1, TF0, TF1) |
DL_TFC5 |
(TF2, TF1, TF1) |
Sub-tests:
Sub-test |
Downlink TFCS under test |
Uplink TFCS Under test |
Implicitly tested |
Restricted UL TFCIs (note 1) |
UL RLC SDU size (note 2) |
Test data size (note 2) |
1 |
DL_TFC1 |
UL_TFC1 |
DL_TFC0, DL_TFC3, UL_TFC0, UL_TFC3 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3, UL_TFC4 |
RB5: 39 bits RB6: 84 bits |
RB5: 39 bits RB6: No data |
2 |
DL_TFC2 |
UL_TFC2 |
DL_TFC0, DL_TFC3, UL_TFC0, UL_TFC3 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3, UL_TFC5, |
RB5: 75 bits RB6: 84 bits |
RB5: 75 bits RB6: 84 bits |
NOTE 1: UL_TFC0, UL_TFC1, UL_TFC2 and UL_TFC3 are part of minimum set of TFCIs. NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs. |
See clause 18.2.1.1 for test procedure.
.
18.2.2.6.4 Test requirements
See 18.2.1.1 for definition of step 10 and step 15.
1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.
2. At step 15 the UE transmitted transport format shall be
– for sub-test 1: RB5/TF1 (1×39).
– for sub-test 2: RB5/TF2 (1×75) and RB6/TF1 (1×84).
3. At step 15 the UE shall return
– for sub-test 1: an RLC SDU on RB5 having the same content as sent by SS; and no data shall be received on RB6.
– for sub-test 2: an RLC SDU on each of RB5 and RB6 having the same content as sent by SS.
18.2.2.7 Conversational / speech / UL:7.4 DL:7.4 kbps / CS RAB+ UL:3.4 DL:3.4 kbps SRBs for DCCH
18.2.2.7.1 Conformance requirement
See clause 18.2.2.4.1.
18.2.2.7.2 Test purpose
To verify radio bearer establishment and correct data transfer for reference radio bearer configuration as specified in TS 34.108, clause 6.10.3.4.1.7.
18.2.2.7.3 Method of test
Uplink TFS:
TFI |
RB5 (RAB subflow #1) |
RB6 (RAB subflow #2) |
DCCH |
|
TFS |
TF0, bits |
0x61 (alt. 1×0) |
0x87 |
0x148 |
TF1, bits |
1×39 |
1×87 |
1×148 |
|
TF2, bits |
1×61 |
N/A |
N/A |
Uplink TFCS:
TFCI |
(RB5, RB6, DCCH) |
UL_TFC0 |
(TF0, TF0, TF0) |
UL_TFC1 |
(TF1, TF0, TF0) |
UL_TFC2 |
(TF2, TF1, TF0) |
UL_TFC3 |
(TF0, TF0, TF1) |
UL_TFC4 |
(TF1, TF0, TF1) |
UL_TFC5 |
(TF2, TF1, TF1) |
Downlink TFS:
RB5 (RAB subflow #1) |
RB6 (RAB subflow #2) |
DCCH |
||
TFS |
TF0, bits |
0x61 (alt. 1×0) |
0x87 |
0x148 |
TF1, bits |
1×39 |
1×87 |
1×148 |
|
TF2, bits |
1×61 |
N/A |
N/A |
Downlink TFCS:
TFCI |
(RB5, RB6, DCCH) |
DL_TFC0 |
(TF0, TF0, TF0) |
DL_TFC1 |
(TF1, TF0, TF0) |
DL_TFC2 |
(TF2, TF1, TF0) |
DL_TFC3 |
(TF0, TF0, TF1) |
DL_TFC4 |
(TF1, TF0, TF1) |
DL_TFC5 |
(TF2, TF1, TF1) |
Sub-tests:
Sub-test |
Downlink TFCS under test |
Uplink TFCS Under test |
Implicitly tested |
Restricted UL TFCIs (note 1) |
UL RLC SDU size (note 2) |
Test data size (note 2) |
1 |
DL_TFC1 |
UL_TFC1 |
DL_TFC0, DL_TFC3, UL_TFC0, UL_TFC3 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3, UL_TFC4 |
RB5: 39 bits RB6: 87 bits |
RB5: 39 bits RB6: No data |
2 |
DL_TFC2 |
UL_TFC2 |
DL_TFC0, DL_TFC3, UL_TFC0, UL_TFC3 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3, UL_TFC5, |
RB5: 61 bits RB6: 87 bits |
RB5: 61 bits RB6: 87 bits |
NOTE 1: UL_TFC0, UL_TFC1, UL_TFC2 and UL_TFC3 are part of minimum set of TFCIs. NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs. |
See clause 18.2.1.1 for test procedure.
18.2.2.7.4 Test requirements
See 18.2.1.1 for definition of step 10 and step 15.
1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.
2. At step 15 the UE transmitted transport format shall be
– for sub-test 1: RB5/TF1 (1×39).
– for sub-test 2: RB5/TF2 (1×61) and RB6/TF1 (1×87).
3. At step 15 the UE shall return
– for sub-test 1: an RLC SDU on RB5 having the same content as sent by SS; and no data shall be received on RB6.
– for sub-test 2: an RLC SDU on each of RB5 and RB6 having the same content as sent by SS
18.2.2.7a Conversational / speech / UL:(7.4, 6.7, 5.9, 4.75) DL:(7.4, 6.7, 5.9, 4.75) kbps / CS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH.
18.2.2.7a.1 Conformance requirement
See clause 18.2.2.4.1.
18.2.2.7a.2 Test purpose
To verify radio bearer establishment and correct data transfer for reference radio bearer configuration as specified in TS 34.108, clause 6.10.3.4.1.7a.
18.2.2.7a.3 Method of test
Uplink TFS:
TFI |
RB5 (RAB subflow #1) |
RB6 (RAB subflow #2) |
DCCH |
|
TFS |
TF0, bits |
0x61(alt. 1×0) |
0x87 |
0x148 |
TF1, bits |
1×39 |
1×53 |
1×148 |
|
TF2, bits |
1×42 |
1×63 |
N/A |
|
TF3, bits |
1×55 |
1×76 |
N/A |
|
TF4, bits |
1×58 |
1×87 |
N/A |
|
TF5, bits |
1×61 |
N/A |
N/A |
Uplink TFCS:
TFCI |
(RB5, RB6, RB7,DCCH) |
UL_TFC0 |
(TF0, TF0, TF0) |
UL_TFC1 |
(TF1, TF0, TF0) |
UL_TFC2 |
(TF2, TF1, TF0) |
UL_TFC3 |
(TF3, TF2, TF0) |
UL_TFC4 |
(TF4, TF3, TF0) |
UL_TFC5 |
(TF5, TF4, TF0) |
UL_TFC6 |
(TF0, TF0, TF1) |
UL_TFC7 |
(TF1, TF0, TF1) |
UL_TFC8 |
(TF2, TF1, TF1) |
UL_TFC9 |
(TF3, TF2, TF1) |
UL_TFC10 |
(TF4, TF3, TF1) |
UL_TFC11 |
(TF5, TF4, TF1) |
Downlink TFS:
RB5 (RAB subflow #1) |
RB6 (RAB subflow #2) |
DCCH |
||
TFS |
TF0, bits |
0x61 (alt. 1×0) |
0x87 |
0x148 |
TF1, bits |
1×39 |
1×53 |
1×148 |
|
TF2, bits |
1×42 |
1×63 |
N/A |
|
TF3, bits |
1×55 |
1×76 |
N/A |
|
TF4, bits |
1×58 |
1×87 |
N/A |
|
TF5, bits |
1×61 |
N/A |
N/A |
Downlink TFCS:
TFCI |
(RB5, RB6, RB7, DCCH) |
DL_TFC0 |
(TF0, TF0, TF0) |
DL_TFC1 |
(TF1, TF0, TF0) |
DL_TFC2 |
(TF2, TF1, TF0) |
DL_TFC3 |
(TF3, TF2, TF0) |
DL_TFC4 |
(TF4, TF3, TF0) |
DL_TFC5 |
(TF5, TF4, TF0) |
DL_TFC6 |
(TF0, TF0, TF1) |
DL_TFC7 |
(TF1, TF0, TF1) |
DL_TFC8 |
(TF2, TF1, TF1) |
DL_TFC9 |
(TF3, TF2, TF1) |
DL_TFC10 |
(TF4, TF3, TF1) |
DL_TFC11 |
(TF5, TF4, TF1) |
Sub-tests:
Sub-test |
Downlink TFCS under test |
Uplink TFCS Under test |
Implicitly tested |
Restricted UL TFCIs (note 1) |
UL RLC SDU size (note 2) |
Test data size (note 2) |
1 |
DL_TFC1 |
UL_TFC1 |
DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3, UL_TFC4, UL_TFC5, UL_TFC6, UL_TFC7 |
RB5: 39 bits RB6: 87 bits |
RB5: 39 bits RB6: No data |
2 |
DL_TFC2 |
UL_TFC2 |
DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3, UL_TFC4, UL_TFC5, UL_TFC6, UL_TFC8 |
RB5: 42 bits RB6: 53 bits |
RB5: 42 bits RB6: 53 bits |
3 |
DL_TFC3 |
UL_TFC3 |
DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3, UL_TFC4, UL_TFC5, UL_TFC6, UL_TFC9 |
RB5: 55 bits RB6: 63 bits |
RB5: 55 bits RB6: 63 bits |
4 |
DL_TFC4 |
UL_TFC4 |
DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3, UL_TFC4, UL_TFC5, UL_TFC6, UL_TFC10 |
RB5: 58 bits RB6: 76 bits |
RB5: 58 bits RB6: 76 bits |
5 |
DL_TFC5 |
UL_TFC5 |
DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3, UL_TFC4, UL_TFC5, UL_TFC6, UL_TFC11 |
RB5: 61 bits RB6: 87 bits |
RB5: 61 bits RB6: 87 bits |
NOTE 1: UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3, UL_TFC4, UL_TFC5 and UL_TFC6 are part of minimum set of TFCIs. NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs. |
See clause 18.2.1.1 for test procedure.
18.2.2.7a.4 Test requirements
See 18.2.1.1 for definition of step 10 and step 15.
1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.
2. At step 15 the UE transmitted transport format shall be
– for sub-test 1: RB5/TF1 (1×39).
– for sub-test 2: RB5/TF2 (1×42) and RB6/TF1 (1×53)
– for sub-test 3: RB5/TF3 (1×55) and RB6/TF2 (1×63)
– for sub-test 4: RB5/TF4 (1×58) and RB6/TF3 (1×76)
– for sub-test 5: RB5/TF5 (1×61) and RB6/TF4 (1×87)
3. At step 15 the UE shall return
– for sub-test 1: an RLC SDU on RB5 having the same content as sent by the SS; and no data shall be received on RB6.
– for sub-test 2 to 5: an RLC SDU on RB5 and RB6 having the same content as sent by the SS.
18.2.2.8 Conversational / speech / UL:6.7 DL:6.7 kbps / CS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH
18.2.2.8.1 Conformance requirement
See clause 18.2.2.4.1.
18.2.2.8.2 Test purpose
To verify radio bearer establishment and correct data transfer for reference radio bearer configuration as specified in TS 34.108, clause 6.10.3.4.1.8.
18.2.2.8.3 Method of test
Uplink TFS:
TFI |
RB5 (RAB subflow #1) |
RB6 (RAB subflow #2) |
DCCH |
|
TFS |
TF0, bits |
0x58(alt. 1×0) |
0x76 |
0x148 |
TF1, bits |
1×39 |
1×76 |
1×148 |
|
TF2, bits |
1×58 |
N/A |
N/A |
Uplink TFCS:
TFCI |
(RB5, RB6, DCCH) |
UL_TFC0 |
(TF0, TF0, TF0) |
UL_TFC1 |
(TF1, TF0, TF0) |
UL_TFC2 |
(TF2, TF1, TF0) |
UL_TFC3 |
(TF0, TF0, TF1) |
UL_TFC4 |
(TF1, TF0, TF1) |
UL_TFC5 |
(TF2, TF1, TF1) |
Downlink TFS:
RB5 (RAB subflow #1) |
RB6 (RAB subflow #2) |
DCCH |
||
TFS |
TF0, bits |
0x58(alt. 1×0) |
0x76 |
0x148 |
TF1, bits |
1×39 |
1×76 |
1×148 |
|
TF2, bits |
1×58 |
N/A |
N/A |
Downlink TFCS:
TFCI |
(RB5, RB6, DCCH) |
DL_TFC0 |
(TF0, TF0, TF0) |
DL_TFC1 |
(TF1, TF0, TF0) |
DL_TFC2 |
(TF2, TF1, TF0) |
DL_TFC3 |
(TF0, TF0, TF1) |
DL_TFC4 |
(TF1, TF0, TF1) |
DL_TFC5 |
(TF2, TF1, TF1) |
Sub-tests:
Sub-test |
Downlink TFCS under test |
Uplink TFCS Under test |
Implicitly tested |
Restricted UL TFCIs (note 1) |
UL RLC SDU size (note 2) |
Test data size (note 2) |
1 |
DL_TFC1 |
UL_TFC1 |
DL_TFC0, DL_TFC3, UL_TFC0, UL_TFC3 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3, UL_TFC4 |
RB5: 39 bits RB6: 76 bits |
RB5: 39 bits RB6: No data |
2 |
DL_TFC2 |
UL_TFC2 |
DL_TFC0, DL_TFC3, UL_TFC0, UL_TFC3 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3, UL_TFC5, |
RB5: 58 bits RB6: 76 bits |
RB5: 58 bits RB6: 76 bits |
NOTE 1: UL_TFC0, UL_TFC1, UL_TFC2 and UL_TFC3 are part of minimum set of TFCIs. NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs. |
See clause 18.2.1.1 for test procedure.
18.2.2.8.4 Test requirements
See clause 18.2.1.1 for definition of step 10 and step 15.
1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.
2. At step 15 the UE transmitted transport format shall be
– for sub-test 1: RB5/TF1 (1×39).
– for sub-test 2: RB5/TF2 (1×58) and RB6/TF1 (1×76).
3. At step 15 the UE shall return
– for sub-test 1: an RLC SDU on RB5 having the same content as sent by SS; and no data shall be received on RB6.
– for sub-test 2: an RLC SDU on each of RB5 and RB6 having the same content as sent by SS
18.2.2.9 Conversational / speech / UL:5.9 DL:5.9 kbps / CS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH
18.2.2.9.1 Conformance requirement
See clause 18.2.2.4.1.
18.2.2.9.2 Test purpose
To verify radio bearer establishment and correct data transfer for reference radio bearer configuration as specified in TS 34.108, clause 6.10.3.4.1.9.
18.2.2.9.3 Method of test
Uplink TFS:
TFI |
RB5 (RAB subflow #1) |
RB6 (RAB subflow #2) |
DCCH |
|
TFS |
TF0, bits |
0x55(alt. 1×0) |
0x63 |
0x148 |
TF1, bits |
1×39 |
1×63 |
1×148 |
|
TF2, bits |
1×55 |
N/A |
N/A |
Uplink TFCS:
TFCI |
(RB5, RB6, DCCH) |
UL_TFC0 |
(TF0, TF0, TF0) |
UL_TFC1 |
(TF1, TF0, TF0) |
UL_TFC2 |
(TF2, TF1, TF0) |
UL_TFC3 |
(TF0, TF0, TF1) |
UL_TFC4 |
(TF1, TF0, TF1) |
UL_TFC5 |
(TF2, TF1, TF1) |
Downlink TFS:
RB5 (RAB subflow #1) |
RB6 (RAB subflow #2) |
DCCH |
||
TFS |
TF0, bits |
0x55 (alt. 1×0) |
0x63 |
0x148 |
TF1, bits |
1×39 |
1×63 |
1×148 |
|
TF2, bits |
1×55 |
N/A |
N/A |
Downlink TFCS:
TFCI |
(RB5, RB6, DCCH) |
DL_TFC0 |
(TF0, TF0, TF0) |
DL_TFC1 |
(TF1, TF0, TF0) |
DL_TFC2 |
(TF2, TF1, TF0) |
DL_TFC3 |
(TF0, TF0, TF1) |
DL_TFC4 |
(TF1, TF0, TF1) |
DL_TFC5 |
(TF2, TF1, TF1) |
Sub-tests:
Sub-test |
Downlink TFCS under test |
Uplink TFCS Under test |
Implicitly tested |
Restricted UL TFCIs (note 1) |
UL RLC SDU size (note 2) |
Test data size (note 2) |
1 |
DL_TFC1 |
UL_TFC1 |
DL_TFC0, DL_TFC3, UL_TFC0, UL_TFC3 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3, UL_TFC4 |
RB5: 39 bits RB6: 63 bits |
RB5: 39 bits RB6: No data |
2 |
DL_TFC2 |
UL_TFC2 |
DL_TFC0, DL_TFC3, UL_TFC0, UL_TFC3 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3, UL_TFC5, |
RB5: 55 bits RB6: 63 bits |
RB5: 55 bits RB6: 63 bits |
NOTE 1: UL_TFC0, UL_TFC1, UL_TFC2 and UL_TFC3 are part of minimum set of TFCIs. NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs. |
See clause 18.2.1.1 for test procedure.
18.2.2.9.4 Test requirements
See 18.2.1.1 for definition of step 10 and step 15.
1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.
2. At step 15 the UE transmitted transport format shall be
– for sub-test 1: RB5/TF1 (1×39).
– for sub-test 2: RB5/TF2 (1×55) and RB6/TF1 (1×63).
3. At step 15 the UE shall return
– for sub-test 1: an RLC SDU on RB5 having the same content as sent by SS; and no data shall be received on RB6.
– for sub-test 2: an RLC SDU on each of RB5 and RB6 having the same content as sent by SS
18.2.2.10 Conversational / speech / UL:5.15 DL:5.15 kbps / CS RAB + UL:1.7 DL:1.7 kbps SRBs for DCCH
18.2.2.10.1 Conformance requirement
See clause 18.2.2.4.1.
18.2.2.10.2 Test purpose
To verify radio bearer establishment and correct data transfer for reference radio bearer configuration as specified in TS 34.108, clause 6.10.3.4.1.10.
18.2.2.10.3 Method of test
Uplink TFS:
TFI |
RB5 (RAB subflow #1) |
RB6 (RAB subflow #2) |
DCCH |
|
TFS |
TF0, bits |
0x49 (alt. 1×0) |
0x54 |
0x148 |
TF1, bits |
1×39 |
1×54 |
1×148 |
|
TF2, bits |
1×49 |
N/A |
N/A |
Uplink TFCS:
TFCI |
(RB5, RB6, DCCH) |
UL_TFC0 |
(TF0, TF0, TF0) |
UL_TFC1 |
(TF1, TF0, TF0) |
UL_TFC2 |
(TF2, TF1, TF0) |
UL_TFC3 |
(TF0, TF0, TF1) |
UL_TFC4 |
(TF1, TF0, TF1) |
UL_TFC5 |
(TF2, TF1, TF1) |
Downlink TFS:
RB5 (RAB subflow #1) |
RB6 (RAB subflow #2) |
DCCH |
||
TFS |
TF0, bits |
0x49 (alt. 1×0) |
0x54 |
0x148 |
TF1, bits |
1×39 |
1×54 |
1×148 |
|
TF2, bits |
1×49 |
N/A |
N/A |
Downlink TFCS:
TFCI |
(RB5, RB6, DCCH) |
DL_TFC0 |
(TF0, TF0, TF0) |
DL_TFC1 |
(TF1, TF0, TF0) |
DL_TFC2 |
(TF2, TF1, TF0) |
DL_TFC3 |
(TF0, TF0, TF1) |
DL_TFC4 |
(TF1, TF0, TF1) |
DL_TFC5 |
(TF2, TF1, TF1) |
Sub-tests:
Sub-test |
Downlink TFCS under test |
Uplink TFCS Under test |
Implicitly tested |
Restricted UL TFCIs (note 1) |
UL RLC SDU size (note 2) |
Test data size (note 2) |
1 |
DL_TFC1 |
UL_TFC1 |
DL_TFC0, DL_TFC3, UL_TFC0, UL_TFC3 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3, UL_TFC4 |
RB5: 39 bits RB6: 54 bits |
RB5: 39 bits RB6: No data |
2 |
DL_TFC2 |
UL_TFC2 |
DL_TFC0, DL_TFC3, UL_TFC0, UL_TFC3 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3, UL_TFC5, |
RB5: 49 bits RB6: 54 bits |
RB5: 49 bits RB6: 54 bits |
NOTE 1: UL_TFC0, UL_TFC1, UL_TFC2 and UL_TFC3 are part of minimum set of TFCIs. NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs. |
See clause 18.2.1.1 for test procedure.
18.2.2.10.4 Test requirements
See 18.2.1.1 for definition of step 10 and step 15.
1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.
2. At step 15 the UE transmitted transport format shall be
– for sub-test 1: RB5/TF1 (1×39).
– for sub-test 2: RB5/TF2 (1×49) and RB6/TF1 (1×54).
3. At step 15 the UE shall return
– for sub-test 1: an RLC SDU on RB5 having the same content as sent by SS; and no data shall be received on RB6.
– for sub-test 2: an RLC SDU on each of RB5 and RB6 having the same content as sent by SS
18.2.2.11 Conversational / speech / UL:4.75 DL:4.75 kbps / CS RAB + UL:1.7 DL:1.7 kbps SRBs for DCCH
18.2.2.11.1 Conformance requirement
See clause 18.2.2.4.1.
18.2.2.11.2 Test purpose
To verify radio bearer establishment and correct data transfer for reference radio bearer configuration as specified in TS 34.108, clause 6.10.3.4.1.11.
18.2.2.11.3 Method of test
Uplink TFS:
TFI |
RB5 (RAB subflow #1) |
RB6 (RAB subflow #2) |
DCCH |
|
TFS |
TF0, bits |
0x49(alt.1×0 ) |
0x53 |
0x148 |
TF1, bits |
1×39 |
1×53 |
1×148 |
|
TF2, bits |
1×42 |
N/A |
N/A |
Uplink TFCS:
TFCI |
(RB5, RB6, DCCH) |
UL_TFC0 |
(TF0, TF0, TF0) |
UL_TFC1 |
(TF1, TF0, TF0) |
UL_TFC2 |
(TF2, TF1, TF0) |
UL_TFC3 |
(TF0, TF0, TF1) |
UL_TFC4 |
(TF1, TF0, TF1) |
UL_TFC5 |
(TF2, TF1, TF1) |
Downlink TFS:
RB5 (RAB subflow #1) |
RB6 (RAB subflow #2) |
DCCH |
||
TFS |
TF0, bits |
0X42 (alt.1×0 ) |
0x53 |
0x148 |
TF1, bits |
1×39 |
1×53 |
1×148 |
|
TF2, bits |
1×42 |
N/A |
N/A |
Downlink TFCS:
TFCI |
(RB5, RB6, DCCH) |
DL_TFC0 |
(TF0, TF0, TF0) |
DL_TFC1 |
(TF1, TF0, TF0) |
DL_TFC2 |
(TF2, TF1, TF0) |
DL_TFC3 |
(TF0, TF0, TF1) |
DL_TFC4 |
(TF1, TF0, TF1) |
DL_TFC5 |
(TF2, TF1, TF1) |
Sub-tests:
Sub-test |
Downlink TFCS under test |
Uplink TFCS Under test |
Implicitly tested |
Restricted UL TFCIs (note 1) |
UL RLC SDU size (note 2) |
Test data size (note 2) |
1 |
DL_TFC1 |
UL_TFC1 |
DL_TFC0, DL_TFC3, UL_TFC0, UL_TFC3 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3, UL_TFC4 |
RB5: 39 bits RB6: 53 bits |
RB5: 39 bits RB6: No data |
2 |
DL_TFC2 |
UL_TFC2 |
DL_TFC0, DL_TFC3, UL_TFC0, UL_TFC3 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3, UL_TFC5, |
RB5: 42 bits RB6: 53 bits |
RB5: 42 bits RB6: 53 bits |
NOTE 1: UL_TFC0, UL_TFC1, UL_TFC2 and UL_TFC3 are part of minimum set of TFCIs. NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs. |
See clause 18.2.1.1 for test procedure.
18.2.2.11.4 Test requirements
See clause 18.2.1.1 for definition of step 10 and step 15.
1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.
2. At step 15 the UE transmitted transport format shall be
– for sub-test 1: RB5/TF1 (1×39).
– for sub-test 2: RB5/TF2 (1×42) and RB6/TF1 (1×53).
3. At step 15 the UE shall return
– for sub-test 1: an RLC SDU on RB5 having the same content as sent by SS; and no data shall be received on RB6.
– for sub-test 2: an RLC SDU on each of RB5 and RB6 having the same content as sent by SS
18.2.2.12 Conversational / unknown / UL:28.8 DL:28.8 kbps / CS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH
18.2.2.12.1 Conformance requirement
See 18.2.2.4.1.
18.2.2.12.2 Test purpose
To verify radio bearer establishment and correct data transfer for reference radio bearer configuration as specified in TS 34.108, clause 6.10.3.4.1.12.
18.2.2.12.3 Method of test
Uplink RLC |
|
TM RLC |
|
Segmentation indication |
FALSE |
Downlink RLC |
|
TM RLC |
|
Segmentation indication |
FALSE |
Uplink TFS:
TFI |
RB5 (28.8 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x576 |
0x148 |
TF1, bits |
1×576 |
1×148 |
Uplink TFCS:
TFCI |
(RB5, DCCH) |
UL_TFC0 |
(TF0, TF0) |
UL_TFC1 |
(TF1, TF0) |
UL_TFC2 |
(TF0, TF1) |
UL_TFC3 |
(TF1, TF1) |
Downlink TFS:
RB5 (28.8 kbps) |
DCCH |
||
TFS |
TF0, bits |
0x576 |
0x148 |
TF1, bits |
1×576 |
1×148 |
Downlink TFCS:
TFCI |
(RB5, DCCH) |
DL_TFC0 |
(TF0, TF0) |
DL_TFC1 |
(TF1, TF0) |
DL_TFC2 |
(TF0, TF1) |
DL_TFC3 |
(TF1, TF1) |
Sub-tests:
Sub-test |
Downlink TFCS under test |
Uplink TFCS Under test |
Implicitly tested |
Restricted UL TFCIs (note 1) |
UL RLC SDU size (bits) (note2 ) |
Test data size (bits) (note 2) |
1 |
DL_TFC1 |
UL_TFC1 |
DL_TFC0, DL_TFC2, UL_TFC0, UL_TFC2 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3 |
RB5: 576 |
RB5: 576 |
NOTE 1: UL_TFC0, UL_TFC1 and UL_TFC2 are part of minimum set of TFCIs. NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs. |
See clause 18.2.1.1 for test procedure.
18.2.2.12.4 Test requirements
See clause 18.2.1.1 for definition of step 10 and step 15.
1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.
2. At step 15 the UE transmitted transport format shall be
– for sub-test 1: RB5/TF1 (1×576).
3. At step 15 the UE shall return
– for sub-test 1: an RLC SDU on RB5 having the same content as sent by SS.
18.2.2.13 Conversational / unknown / UL:64 DL:64 kbps / CS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH
18.2.2.13.1 Conformance requirement
See clause 18.2.2.4.1.
18.2.2.13.2 Test purpose
To verify radio bearer establishment and correct data transfer for reference radio bearer configuration as specified in TS 34.108, clause 6.10.3.4.1.13.
18.2.2.13.3 Method of test
Initial Conditions
The following RLC Info parameter values shall be set by the SS:
Uplink RLC |
|
TM RLC |
|
Transmission RLC discard |
|
CHOICE SDU Discard Mode |
|
Timer based no explicit |
|
Timer_discard |
100ms |
Segmentation indication |
FALSE |
Downlink RLC |
|
TM RLC |
|
Segmentation indication |
FALSE |
NOTE: Timer based discard without explicit signalling is used in uplink to secure that the UE will be able to return data for the case when the UE test loop function will not deliver all the SDUs in one and the same TTI . |
Uplink TFS:
TFI |
RB5 (64 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x640 |
0x148 |
TF1, bits |
2×640 |
1×148 |
Uplink TFCS:
TFCI |
(RB5, DCCH) |
UL_TFC0 |
(TF0, TF0) |
UL_TFC1 |
(TF1, TF0) |
UL_TFC2 |
(TF0, TF1) |
UL_TFC3 |
(TF1, TF1) |
Downlink TFS:
TFI |
RB5 (64 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x640 |
0x148 |
TF1, bits |
2×640 |
1×148 |
Downlink TFCS:
TFCI |
(RB5, DCCH) |
DL_TFC0 |
(TF0, TF0) |
DL_TFC1 |
(TF1, TF0) |
DL_TFC2 |
(TF0, TF1) |
DL_TFC3 |
(TF1, TF1) |
Sub-tests:
Sub-test |
Downlink TFCS Under test |
Uplink TFCS Under test |
Implicitly tested |
Restricted UL TFCIs (note 1) |
UL RLC SDU size (bits) (note 2) |
Test data size (bits) (note 2) |
1 |
DL_TFC1 |
UL_TFC1 |
DL_TFC0, DL_TFC2, UL_TFC0, UL_TFC2 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3 |
RB5: 640 |
RB5: 2×640 |
NOTE 1: UL_TFC0, UL_TFC1, and UL_TFC2 are part of minimum set of TFCIs. NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs. |
See clause 18.2.1.1 for test procedure.
18.2.2.13.4 Test requirements
See clause 18.2.1.1 for definition of step 10 and step 15.
1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.
2. At step 15 the UE transmitted transport format shall be
– for sub-test 1: RB5/TF1 (2×640).
3. At step 15 the UE shall return
– for sub-test 1: two RLC SDUs on RB5 having the same content as sent by SS.
18.2.2.14 Conversational / unknown / UL:32 DL:32 kbps / CS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH
18.2.2.14.1 Conformance requirement
See 18.2.2.4.1.
18.2.2.14.2 Test purpose
To verify radio bearer establishment and correct data transfer for reference radio bearer configuration as specified in TS 34.108, clause 6.10.3.4.1.14.
18.2.2.14.3 Method of test
Initial Conditions
The following RLC Info parameter values shall be set by the SS:
Uplink RLC |
|
TM RLC |
|
Segmentation indication |
FALSE |
Downlink RLC |
|
TM RLC |
|
Segmentation indication |
FALSE |
Uplink TFS:
TFI |
RB5 (32 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x640 |
0x148 |
TF1, bits |
1×640 |
1×148 |
Uplink TFCS:
TFCI |
(RB5, DCCH) |
UL_TFC0 |
(TF0, TF0) |
UL_TFC1 |
(TF1, TF0) |
UL_TFC2 |
(TF0, TF1) |
UL_TFC3 |
(TF1, TF1) |
Downlink TFS:
TFI |
RB5 (32 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x640 |
0x148 |
TF1, bits |
1×640 |
1×148 |
Downlink TFCS:
TFCI |
(RB5, DCCH) |
DL_TFC0 |
(TF0, TF0) |
DL_TFC1 |
(TF1, TF0) |
DL_TFC2 |
(TF0, TF1) |
DL_TFC3 |
(TF1, TF1) |
Sub-tests:
Sub-test |
Downlink TFCS Under test |
Uplink TFCS Under test |
Implicitly tested |
Restricted UL TFCIs (note 1) |
UL RLC SDU size (bits) (note 2) |
Test data size (bits) (note 2) |
1 |
DL_TFC1 |
UL_TFC1 |
DL_TFC0, DL_TFC2, UL_TFC0, UL_TFC2 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3 |
RB5: 640 |
RB5: 640 |
NOTE 1: UL_TFC0, UL_TFC1, and UL_TFC2 are part of minimum set of TFCIs. NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs. |
See 18.2.1.1 for test procedure.
18.2.2.14.4 Test requirements
1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.
2. At step 15 the UE transmitted transport format shall be
– for sub-test 1: RB5/TF1 (1×640).
3. At step 15 the UE shall return
– for sub-test 1: an RLC SDU on RB5 having the same content as sent by SS.
18.2.2.15 Streaming / unknown / UL:14.4/DL:14.4 kbps / CS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH
18.2.2.15.1 Conformance requirement
See 18.2.2.4.1.
18.2.2.15.2 Test purpose
To verify radio bearer establishment and correct data transfer for reference radio bearer configuration as specified in TS 34.108, clause 6.10.3.4.1.15.
18.2.2.15.3 Method of test
Uplink TFS:
TFI |
RB5 (14.4 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x576 |
0x148 |
TF1, bits |
1×576 |
1×148 |
Uplink TFCS:
TFCI |
(RB5, DCCH) |
UL_TFC0 |
(TF0, TF0) |
UL_TFC1 |
(TF1, TF0) |
UL_TFC2 |
(TF0, TF1) |
UL_TFC3 |
(TF1, TF1) |
Downlink TFS:
TFI |
RB5 (14.4 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x576 |
0x148 |
TF1, bits |
1×576 |
1×148 |
Downlink TFCS:
TFCI |
(RB5, DCCH) |
DL_TFC0 |
(TF0, TF0) |
DL_TFC1 |
(TF1, TF0) |
DL_TFC2 |
(TF0, TF1) |
DL_TFC3 |
(TF1, TF1) |
Sub-tests:
Sub-test |
Downlink TFCS Under test |
Uplink TFCS Under test |
Implicitly tested |
Restricted UL TFCIs (note 1) |
UL RLC SDU size (bits) (note 2) |
Test data size (bits) (note 2) |
1 |
DL_TFC1 |
UL_TFC1 |
DL_TFC0, DL_TFC2, UL_TFC0, UL_TFC2 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3 |
RB5: 576 |
RB5: 576 |
NOTE 1: UL_TFC0, UL_TFC1, and UL_TFC2 are part of minimum set of TFCIs. NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs. |
See 18.2.1.1 for test procedure.
18.2.2.15.4 Test requirements
See 18.2.1.1 for definition of step 10 and step 15.
1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.
2. At step 15 the UE transmitted transport format shall be
– for sub-test 1: RB5/TF1 (1×576).
3. At step 15 the UE shall return
– for sub-test 1: an RLC SDU on RB5 having the same content as sent by SS.
18.2.2.16 Streaming / unknown / UL:28.8/DL:28.8 kbps / CS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH
18.2.2.16.1 Conformance requirement
See 18.2.2.4.1.
18.2.2.16.2 Test purpose
To verify radio bearer establishment and correct data transfer for reference radio bearer configuration as specified in TS 34.108, clause 6.10.3.4.1.16.
18.2.2.16.3 Method of test
Uplink TFS:
TFI |
RB5 (28.8 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x576 |
0x148 |
TF1, bits |
1×576 |
1×148 |
Uplink TFCS:
TFCI |
(RB5, DCCH) |
UL_TFC0 |
(TF0, TF0) |
UL_TFC1 |
(TF1, TF0) |
UL_TFC2 |
(TF0, TF1) |
UL_TFC3 |
(TF1, TF1) |
Downlink TFS:
RB5 (28.8 kbps) |
DCCH |
||
TFS |
TF0, bits |
0x576 |
0x148 |
TF1, bits |
1×576 |
1×148 |
Downlink TFCS:
TFCI |
(RB5, DCCH) |
DL_TFC0 |
(TF0, TF0) |
DL_TFC1 |
(TF1, TF0) |
DL_TFC2 |
(TF0, TF1) |
DL_TFC3 |
(TF1, TF1) |
Sub-tests:
Sub-test |
Downlink TFCS Under test |
Uplink TFCS Under test |
Implicitly tested |
Restricted UL TFCIs (note 1) |
UL RLC SDU size (bits) (note 2) |
Test data size (bits) (note 2) |
1 |
DL_TFC1 |
UL_TFC1 |
DL_TFC0, DL_TFC2, UL_TFC0, UL_TFC2 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3 |
RB5: 576 |
RB5: 576 |
NOTE 1: UL_TFC0, UL_TFC1 and UL_TFC2 are part of minimum set of TFCIs. NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs. |
See 18.2.1.1 for test procedure.
18.2.2.16.4 Test requirements
See 18.2.1.1 for definition of step 10 and step 15.
1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.
2. At step 15 the UE transmitted transport format shall be
– for sub-test 1: RB5/TF1 (1×576).
3. At step 15 the UE shall return
– for sub-test 1: an RLC SDU on RB5 having the same content as sent by SS.
18.2.2.17 Streaming / unknown / UL:57.6/DL:57.6 kbps / CS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH
18.2.2.17.1 Conformance requirement
See 18.2.2.4.1.
18.2.2.17.2 Test purpose
To verify radio bearer establishment and correct data transfer for reference radio bearer configuration as specified in TS 34.108, clause 6.10.3.4.1.17.
18.2.2.17.3 Method of test
Initial Conditions
The following RLC Info parameter values shall be set by the SS:
Uplink RLC |
|
TM RLC |
|
Transmission RLC discard |
|
CHOICE SDU Discard Mode |
|
Timer based no explicit |
|
Timer_discard |
100ms |
Segmentation indication |
FALSE |
Downlink RLC |
|
TM RLC |
|
Segmentation indication |
FALSE |
NOTE: Timer based discard without explicit signalling is used in uplink to secure that the UE will be able to return data for the case when the UE test loop function will not deliver all the SDUs in one and the same TTI . |
Uplink TFS:
TFI |
RB5 (57.6 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x576 |
0x148 |
TF1, bits |
1×576 |
1×148 |
|
TF2, bits |
2×576 |
N/A |
|
TF3, bits |
3×576 |
N/A |
|
TF4, bits |
4×576 |
N/A |
Uplink TFCS:
TFCI |
(RB5, DCCH) |
UL_TFC0 |
(TF0, TF0) |
UL_TFC1 |
(TF1, TF0) |
UL_TFC2 |
(TF2, TF0) |
UL_TFC3 |
(TF3, TF0) |
UL_TFC4 |
(TF4, TF0) |
UL_TFC5 |
(TF0, TF1) |
UL_TFC6 |
(TF1, TF1) |
UL_TFC7 |
(TF2, TF1) |
UL_TFC8 |
(TF3, TF1) |
UL_TFC9 |
(TF4, TF1) |
Downlink TFS:
TFI |
RB5 (57.6 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x576 |
0x148 |
TF1, bits |
1×576 |
1×148 |
|
TF2, bits |
2×576 |
N/A |
|
TF3, bits |
3×576 |
N/A |
|
TF4, bits |
4×576 |
N/A |
Downlink TFCS:
TFCI |
(RB5, DCCH) |
DL_TFC0 |
(TF0, TF0) |
DL_TFC1 |
(TF1, TF0) |
DL_TFC2 |
(TF2, TF0) |
DL_TFC3 |
(TF3, TF0) |
DL_TFC4 |
(TF4, TF0) |
DL_TFC5 |
(TF0, TF1) |
DL_TFC6 |
(TF1, TF1) |
DL_TFC7 |
(TF2, TF1) |
DL_TFC8 |
(TF3, TF1) |
DL_TFC9 |
(TF4, TF1) |
Sub-tests:
Sub-test |
Downlink TFCS Under test |
Uplink TFCS Under test |
Implicitly tested |
Restricted UL TFCIs |
UL RLC SDU size (bits) (note) |
Test data size (bits) (note) |
1 |
DL_TFC1 |
UL_TFC1 |
DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5, |
UL_TFC0, UL_TFC1, UL_TFC5, UL_TFC6 |
RB5: 576 |
RB5: 576 |
2 |
DL_TFC2 |
UL_TFC2 |
DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC5, UL_TFC7 |
RB5: 576 |
RB5: 2×576 |
3 |
DL_TFC3 |
UL_TFC3 |
DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC3, UL_TFC5, UL_TFC8 |
RB5: 576 |
RB5: 3×576 |
4 |
DL_TFC4 |
UL_TFC4 |
DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC4, UL_TFC5, UL_TFC9 |
RB5: 576 |
RB5: 4×576 |
NOTE 1: UL_TFC0, UL_TFC1 and UL_TFC5 are part of minimum set of TFCIs. NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs. |
See 18.2.1.1 for test procedure.
18.2.2.17.4 Test requirements
See 18.2.1.1 for definition of step 10 and step 15.
1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.
2. At step 15 the UE transmitted transport format shall be
– for sub-test 1: RB5/TF1 (1×576).
– for sub-test 2: RB5/TF2 (2×576) or RB5/TF1 (1×576).
– for sub-test 3: RB5/TF3 (3×576) or RB5/TF1 (1×576).
– for sub-test 4: RB5/TF4 (4×576) or RB5/TF1 (1×576).
3. At step 15 the UE shall return
– for sub-test 1: one RLC SDU on RB5 having the same content as sent by SS.
– for sub-test 2: two RLC SDU on RB5 having the same content as sent by SS.
– for sub-test 3: three RLC SDU on RB5 having the same content as sent by SS.
– for sub-test 4: four RLC SDU on RB5 having the same content as sent by SS.
18.2.2.18 Void
18.2.2.19 Void
18.2.2.20 Void
18.2.2.21 Void
18.2.2.22 Void
18.2.2.23 Interactive or background / UL:32 DL:8 kbps / PS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH
18.2.2.23.1 Interactive or background / UL:32 DL:8 kbps / PS RAB / (Payload size 320)
18.2.2.23.1.1 Conformance requirement
See 18.2.2.4.1.
18.2.2.23.1.2 Test purpose
Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.10.3.4.1.23 for uplink payload size 320 case.
18.2.2.23.1.3 Method of test
Uplink TFS:
TFI |
RB5 (32 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x336 |
0x148 |
TF1, bits |
1×336 |
1×148 |
|
TF2, bits |
2×336 |
N/A |
Uplink TFCS:
TFCI |
(RB5, DCCH) |
UL_TFC0 |
(TF0, TF0) |
UL_TFC1 |
(TF1, TF0) |
UL_TFC2 |
(TF2, TF0) |
UL_TFC3 |
(TF0, TF1) |
UL_TFC4 |
(TF1, TF1) |
UL_TFC5 |
(TF2, TF1) |
Downlink TFS:
TFI |
RB5 (8 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x336 |
0x148 |
TF1, bits |
1×336 |
1×148 |
Downlink TFCS:
TFCI |
(RB5, DCCH) |
DL_TFC0 |
(TF0, TF0) |
DL_TFC1 |
(TF1, TF0) |
DL_TFC2 |
(TF0, TF1) |
DL_TFC3 |
(TF1, TF1) |
Sub-tests:
Sub-test |
Downlink TFCS Under test |
Uplink TFCS Under test |
Implicitly tested |
Restricted UL TFCIs (note 1) |
UL RLC SDU size (bits) (note 2) |
Test data size (bits) (note 2) |
1 |
DL_TFC1 |
UL_TFC1 |
DL_TFC0, DL_TFC2, UL_TFC0, UL_TFC3 |
UL_TFC0, UL_TFC1, UL_TFC3, UL_TFC4 |
RB5: 312 |
RB5: 312 |
2 |
DL_TFC1 |
UL_TFC2 |
DL_TFC0, DL_TFC2, UL_TFC0, UL_TFC3 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3, UL_TFC5 |
RB5: 632 |
RB5: 632 |
NOTE 1: UL_TFC0, UL_TFC1, and UL_TFC3 are part of minimum set of TFCIs. NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs. |
See 18.2.1.1 for test procedure.
18.2.2.23.1.4 Test requirements
See 18.2.1.1 for definition of step 10 and step 15.
1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.
2. At step 15 the UE transmitted transport format shall be
– for sub-test 1: RB5/TF1 (1×336).
– for sub-test 2: RB5/TF2 (2×336).
3. At step 15 the UE shall return
– for sub-test 1 and 2: an RLC SDU on RB5 having the same content as the DL RLC SDU sent by the SS.
18.2.2.23.2 Interactive or background / UL:32 DL:8 kbps / PS RAB / Payload size 128
18.2.2.23.2.1 Conformance requirement
See 18.2.2.4.1.
18.2.2.23.2.2 Test purpose
Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.10.3.4.1.23 for the uplink payload size 128 case.
18.2.2.23.2.3 Method of test
Uplink TFS:
TFI |
RB5 (32 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x144 |
0x148 |
TF1, bits |
1×144 |
1×148 |
|
TF2, bits |
5×144 |
N/A |
Uplink TFCS:
TFCI |
(RB5, DCCH) |
UL_TFC0 |
(TF0, TF0) |
UL_TFC1 |
(TF1, TF0) |
UL_TFC2 |
(TF2, TF0) |
UL_TFC3 |
(TF0, TF1) |
UL_TFC4 |
(TF1, TF1) |
UL_TFC5 |
(TF2, TF1) |
Downlink TFS:
TFI |
RB5 (8 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x336 |
0x148 |
TF1, bits |
1×336 |
1×148 |
Downlink TFCS:
TFCI |
(RB5, DCCH) |
DL_TFC0 |
(TF0, TF0) |
DL_TFC1 |
(TF1, TF0) |
DL_TFC2 |
(TF0, TF1) |
DL_TFC3 |
(TF1, TF1) |
Sub-tests:
Sub-test |
Downlink TFCS Under test |
Uplink TFCS Under test |
Implicitly tested |
Restricted UL TFCIs (note 1) |
UL RLC SDU size (bits) (note 2) |
Test data size (bits) (note 2) |
1 |
DL_TFC1 |
UL_TFC1 |
DL_TFC0, DL_TFC2, UL_TFC0, UL_TFC3 |
UL_TFC0, UL_TFC1, UL_TFC3, UL_TFC4 |
RB5: 376 |
RB5: 312 |
2 |
DL_TFC1 |
UL_TFC2 |
DL_TFC0, DL_TFC2, UL_TFC0, UL_TFC3 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3, UL_TFC5 |
RB5: 632 |
RB5: 312 |
NOTE 1: UL_TFC0, UL_TFC1, and UL_TFC3 are part of minimum set of TFCIs. NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs. |
See 18.2.1.1 for test procedure.
18.2.2.23.2.4 Test requirements
See 18.2.1.1 for definition of step 10 and step 15.
1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.
2. At step 15 the UE transmitted transport format shall be
– for sub-test 1: RB5/TF1 (1×144).
– for sub-test 2: RB5/TF2 (5×144).
3. At step 15 the UE shall return
– for sub-test 1: an RLC SDU on RB5 having the same content as 1 times plus 64 lsb’s of the DL RLC SDU sent by the SS.
– for sub-test 2: an RLC SDU on RB5 having the same content as 2 times plus 8 lsb’s of the DL RLC SDU sent by the SS.
18.2.2.23a Interactive or background / UL:8 DL:8 kbps / PS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH.
18.2.2.23a.1 Interactive or background / UL:8 DL:8 kbps / PS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH / 40 ms TTI
18.2.2.23a.1.1 Conformance requirement
See 18.2.2.4.1.
18.2.2.23a.1.2 Test purpose
Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.10.3.4.1.23a, for the uplink 40 ms TT case.
18.2.2.23a.1.3 Method of test
See 18.2.1.1 for test procedure.
Uplink TFS:
TFI |
RB5 (8 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x336 |
0x148 |
TF1, bits |
1×336 |
1×148 |
Uplink TFCS:
TFCI |
(8 kbps RAB, DCCH) |
UL_TFC0 |
(TF0, TF0) |
UL_TFC1 |
(TF1, TF0) |
UL_TFC2 |
(TF0, TF1) |
UL_TFC3 |
(TF1, TF1) |
Downlink TFS:
RB5 (8 kbps) |
DCCH |
||
TFS |
TF0, bits |
0x336 |
0x148 |
TF1, bits |
1×336 |
1×148 |
Downlink TFCS:
TFCI |
(8 kbps RAB, DCCH) |
DL_TFC0 |
(TF0, TF0) |
DL_TFC1 |
(TF1, TF0) |
DL_TFC2 |
(TF0, TF1) |
DL_TFC3 |
(TF1, TF1) |
Sub-tests:
Sub-test |
Downlink TFCS Under Test |
Uplink TFCS Under test |
Implicitly tested |
Restricted UL TFCIs (note 1) |
UL RLC SDU size (bits) (note 2) |
Test data size (bits) (note 2) |
---|---|---|---|---|---|---|
1 |
DL_TFC1 |
UL_TFC1 |
DL_TFC0, DL_TFC2, UL_TFC0, UL_TFC2, |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3 |
RB5: 312 |
RB5: 312 |
NOTE 1: UL_TFC0, UL_TFC1, and UL_TFC2 are part of minimum set of TFCIs. NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs. RB5: Test data size has been set to DL TFS size under test minus 8 bits (size of 7 bit length indicator and expansion bit). The UL RLC SDU size has been set equal to the uplink TFS size under test minus 8 bits (size of 7 bit length indicator and expansion bit). |
18.2.2.23a.1.4 Test requirements
See 18.2.1.1 for definition of step 10 and step 15.
1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.
2. At step 15 the UE transmitted transport format shall be
– for sub-test 1: RB5/TF1 (1×336).
3. At step 15 the UE shall return
– for sub-test 1: an RLC SDU on RB5 having the same content as the DL RLC SDU sent by the SS.
18.2.2.23a.2 Interactive or background / UL:8 DL:8 kbps / PS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH / 80 ms TTI
Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.10.3.4.1.23a, for the uplink 80 ms TTI case.
See test case 18.2.2.23.2 for test procedure and test requirement.
18.2.2.23b Interactive or background / UL:16 DL:16 kbps / PS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH.
18.2.2.23b.1 Interactive or background / UL:16 DL:16 kbps / PS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH / Payload size 320.
18.2.2.23b.1.1 Conformance requirement
See clause 18.2.2.4.1.
18.2.2.23b.1.2 Test purpose
Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.10.3.4.1.23b, for the uplink payload size 320 case.
18.2.2.23b.1.3 Method of test
Uplink TFS:
TFI |
RB5 (16 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x336 |
0x148 |
TF1, bits |
1×336 |
1×148 |
|
TF2, bits |
2×336 |
N/A |
Uplink TFCS:
TFCI |
(RB5, DCCH) |
UL_TFC0 |
(TF0, TF0) |
UL_TFC1 |
(TF1, TF0) |
UL_TFC2 |
(TF2, TF0) |
UL_TFC3 |
(TF0, TF1) |
UL_TFC4 |
(TF1, TF1) |
UL_TFC5 |
(TF2, TF1) |
Downlink TFS:
TFI |
RB5 (32 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x336 |
0x148 |
TF1, bits |
1×336 |
1×148 |
|
TF2, bits |
2×336 |
N/A |
Downlink TFCS:
TFCI |
(RB5, DCCH) |
DL_TFC0 |
(TF0, TF0) |
DL_TFC1 |
(TF1, TF0) |
DL_TFC2 |
(TF2, TF0) |
DL_TFC3 |
(TF0, TF1) |
DL_TFC4 |
(TF1, TF1) |
DL_TFC5 |
(TF2, TF1) |
Sub-tests:
Sub-test |
Downlink TFCS Under test |
Uplink TFCS Under test |
Implicitly tested |
Restricted UL TFCIs (note 1) |
UL RLC SDU size (bits) (note 2) |
Test data size (bits) (note 2) |
1 |
DL_TFC1 |
UL_TFC1 |
DL_TFC0, UL_TFC0 DL_TFC3,UL_TFC3 |
UL_TFC0, UL_TFC1, UL_TFC3, UL_TFC4 |
RB5: 312 |
RB5: 312 |
2 |
DL_TFC2 |
UL_TFC2 |
DL_TFC0, UL_TFC0 DL_TFC3 ,UL_TFC3 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3, UL_TFC5 |
RB5: 632 |
RB5: 632 |
NOTE 1: UL_TFC0, UL_TFC1 and UL_TFC3 are part of minimum set of TFCIs. NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs. |
See 18.2.1.1 for test procedure.
18.2.2.23b.1.4 Test requirements
See 18.2.1.1 for definition of step 10 and step 15.
1. At step 10 the UE shall send a RADIO BEARER SETUP COMPLETE message.
2. At step 15 the UE transmitted transport format shall be
– for sub-test 1: RB5/TF1 (1×336).
– for sub-test 2: RB5/TF2 (2×336) or RB5/TF1 (1×336).
3. At step 15 the UE shall return
– for sub-test 1 and 2: an RLC SDU on RB5 having the same content as sent by the SS.
18.2.2.23b.2 Interactive or background / UL:16 DL:16 kbps / PS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH / Payload size 128.
18.2.2.23b.2.1 Conformance requirement
See clause 18.2.2.4.1.
18.2.2.23b.2.2 Test purpose
Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.10.3.4.1.23b, for the uplink payload size 128 case.
18.2.2.23b.2.3 Method of test
Uplink TFS:
TFI |
RB5 (16 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x144 |
0x148 |
TF1, bits |
1×144 |
1×148 |
|
TF2, bits |
5×144 |
N/A |
Uplink TFCS:
TFCI |
(RB5, DCCH) |
UL_TFC0 |
(TF0, TF0) |
UL_TFC1 |
(TF1, TF0) |
UL_TFC2 |
(TF2, TF0) |
UL_TFC3 |
(TF0, TF1) |
UL_TFC4 |
(TF1, TF1) |
UL_TFC5 |
(TF2, TF1) |
Downlink TFS:
TFI |
RB5 (32 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x336 |
0x148 |
TF1, bits |
1×336 |
1×148 |
|
TF2, bits |
2×336 |
N/A |
Downlink TFCS:
TFCI |
(RB5, DCCH) |
DL_TFC0 |
(TF0, TF0) |
DL_TFC1 |
(TF1, TF0) |
DL_TFC2 |
(TF2, TF0) |
DL_TFC3 |
(TF0, TF1) |
DL_TFC4 |
(TF1, TF1) |
DL_TFC5 |
(TF2, TF1) |
Sub-tests:
Sub-test |
Downlink TFCS Under test |
Uplink TFCS Under test |
Implicitly tested |
Restricted UL TFCIs (note 1) |
UL RLC SDU size (bits) (note 2) |
Test data size (bits) (note 2) |
1 |
DL_TFC1 |
UL_TFC1 |
DL_TFC0, UL_TFC0 DL_TFC3,UL_TFC3 |
UL_TFC0, UL_TFC1, UL_TFC3, UL_TFC4 |
RB5: 376 |
RB5: 312 |
2 |
DL_TFC2 |
UL_TFC2 |
DL_TFC0, UL_TFC0 DL_TFC3 ,UL_TFC3 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3, UL_TFC5 |
RB5: 632 |
RB5: 632 |
NOTE 1: UL_TFC0, UL_TFC1 and UL_TFC3 are part of minimum set of TFCIs. NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs. |
See 18.2.1.1 for test procedure.
18.2.2.23b.2.4 Test requirements
See 18.2.1.1 for definition of step 10 and step 15.
1. At step 10 the UE shall send a RADIO BEARER SETUP COMPLETE message.
2. At step 15 the UE transmitted transport format shall be
– for sub-test 1: RB5/TF1 (1×144).
– for sub-test 2: RB5/TF2 (5×144).
3. At step 15 the UE shall return
– for sub-test 1: an RLC SDU on RB5 having the same content as 1 times plus 64 lsb’s of the DL RLC SDU sent by the SS.
– for sub-test 2: an RLC SDU on RB5 having the same content as sent by the SS.
18.2.2.23c Interactive or background / UL:32 DL:32 kbps / PS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH.
18.2.2.23c.1 Interactive or background / UL:32 DL:32 kbps / PS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH / Payload size 320.
18.2.2.23c.1.1 Conformance requirement
See 18.2.2.4.1.
18.2.2.23c.1.2 Test purpose
Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.10.3.4.1.23c the uplink payload size 320 case.
18.2.2.23c.1.3 Method of test
Uplink TFS:
TFI |
RB5 (32 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x336 |
0x148 |
TF1, bits |
1×336 |
1×148 |
|
TF2, bits |
2×336 |
N/A |
|
TF3, bits |
3×336 |
N/A |
|
TF4, bits |
4×336 |
N/A |
Uplink TFCS:
TFCI |
(RB5, DCCH) |
UL_TFC0 |
(TF0, TF0) |
UL_TFC1 |
(TF1, TF0) |
UL_TFC2 |
(TF2, TF0) |
UL_TFC3 |
(TF3, TF0) |
UL_TFC4 |
(TF4, TF0) |
UL_TFC5 |
(TF0, TF1) |
UL_TFC6 |
(TF1, TF1) |
UL_TFC7 |
(TF2, TF1) |
UL_TFC8 |
(TF3, TF1) |
UL_TFC9 |
(TF4, TF1) |
Downlink TFS:
TFI |
RB5 (32 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x336 |
0x148 |
TF1, bits |
1×336 |
1×148 |
|
TF2, bits |
2×336 |
N/A |
|
TF3, bits |
3×336 |
N/A |
|
TF4, bits |
4×336 |
N/A |
Downlink TFCS:
TFCI |
(RB5, DCCH) |
DL_TFC0 |
(TF0, TF0) |
DL_TFC1 |
(TF1, TF0) |
DL_TFC2 |
(TF2, TF0) |
DL_TFC3 |
(TF3, TF0) |
DL_TFC4 |
(TF4, TF0) |
DL_TFC5 |
(TF0, TF1) |
DL_TFC6 |
(TF1, TF1) |
DL_TFC7 |
(TF2, TF1) |
DL_TFC8 |
(TF3, TF1) |
DL_TFC9 |
(TF4, TF1) |
Sub-tests:
Sub-test |
Downlink TFCS Under test |
Uplink TFCS Under test |
Implicitly tested |
Restricted UL TFCIs (note 1) |
UL RLC SDU size (bits) (note 2) |
Test data size (bits) (note 2) |
1 |
DL_TFC1 |
UL_TFC1 |
DL_TFC0, UL_TFC0 DL_TFC5,UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC5, UL_TFC6 |
RB5: 312 |
RB5: 312 |
2 |
DL_TFC2 |
UL_TFC2 |
DL_TFC0, UL_TFC0 DL_TFC5 ,UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC5, UL_TFC7 |
RB5: 632 |
RB5: 632 |
3 |
DL_TFC3 |
UL_TFC3 |
DL_TFC0, UL_TFC0 DL_TFC5 ,UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC3, UL_TFC5, UL_TFC8 |
RB5: 952 |
RB5: 952 |
4 |
DL_TFC4 |
UL_TFC4 |
DL_TFC0, UL_TFC0 DL_TFC5 ,UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC4, UL_TFC5, UL_TFC9 |
RB5: 1272 |
RB5: 1272 |
NOTE 1: UL_TFC0, UL_TFC1 and UL_TFC5 are part of minimum set of TFCIs. NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs. For RB5: Test data size has been set to the payload size of the DL TF under test minus 8 bits (size of 7 bit length indicator and expansion bit). The UL RLC SDU size has been set equal to the size of the payload size of the UL TF under test minus 8 bits (the size of 7 bit length indicator and expansion bit). |
See 18.2.1.1 for test procedure.
18.2.2.23c.1.4 Test requirements
See 18.2.1.1 for definition of step 10 and step 15.
1. At step 10 the UE shall send a RADIO BEARER SETUP COMPLETE message.
2. At step 15 the UE transmitted transport format shall be
– for sub-test 1: RB5/TF1 (1×336).
– for sub-test 2: RB5/TF2 (2×336) or RB5/TF1 (1×336).
– for sub-test 3: RB5/TF3 (3×336) or RB5/TF1 (1×336).
– for sub-test 4: RB5/TF4 (4×336) or RB5/TF1 (1×336).
3. At step 15 the UE shall return
– for sub-test 1 to 4: an RLC SDU on RB5 having the same content as the DL RLC SDU sent by the SS.
18.2.2.23c.2 Interactive or background / UL:32 DL:32 kbps / PS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH / Payload size 128.
18.2.2.23c.2.1 Conformance requirement
See clause 18.2.2.4.1.
18.2.2.23c.2.2 Test purpose
Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.10.3.4.1.23c, for the uplink payload size 128 case.
18.2.2.23c.2.3 Method of test
Uplink TFS:
TFI |
RB5 (16 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x144 |
0x148 |
TF1, bits |
1×144 |
1×148 |
|
TF2, bits |
5×144 |
N/A |
|
TF3, bits |
7×144 |
N/A |
|
TF4, bits |
10×144 |
N/A |
Uplink TFCS:
TFCI |
(RB5, DCCH) |
UL_TFC0 |
(TF0, TF0) |
UL_TFC1 |
(TF1, TF0) |
UL_TFC2 |
(TF2, TF0) |
UL_TFC3 |
(TF3, TF0) |
UL_TFC4 |
(TF4, TF0) |
UL_TFC5 |
(TF0, TF1) |
UL_TFC6 |
(TF1, TF1) |
UL_TFC7 |
(TF2, TF1) |
UL_TFC8 |
(TF3, TF1) |
UL_TFC9 |
(TF4, TF1) |
Downlink TFS:
TFI |
RB5 (32 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x336 |
0x148 |
TF1, bits |
1×336 |
1×148 |
|
TF2, bits |
2×336 |
N/A |
|
TF3, bits |
3×336 |
N/A |
|
TF4, bits |
4×336 |
N/A |
Downlink TFCS:
TFCI |
(RB5, DCCH) |
DL_TFC0 |
(TF0, TF0) |
DL_TFC1 |
(TF1, TF0) |
DL_TFC2 |
(TF2, TF0) |
DL_TFC3 |
(TF3, TF0) |
DL_TFC4 |
(TF4, TF0) |
DL_TFC5 |
(TF0, TF1) |
DL_TFC6 |
(TF1, TF1) |
DL_TFC7 |
(TF2, TF1) |
DL_TFC8 |
(TF3, TF1) |
DL_TFC9 |
(TF4, TF1) |
Sub-tests:
Sub-test |
Downlink TFCS Under test |
Uplink TFCS Under test |
Implicitly tested |
Restricted UL TFCIs (note 1) |
UL RLC SDU size (bits) (note 2) |
Test data size (bits) (note 2) |
1 |
DL_TFC1 |
UL_TFC1 |
DL_TFC0, UL_TFC0 DL_TFC5,UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC5, UL_TFC6 |
RB5: 376 |
RB5: 312 |
2 |
DL_TFC2 |
UL_TFC2 |
DL_TFC0, UL_TFC0 DL_TFC5 ,UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC5, UL_TFC7 |
RB5: 632 |
RB5: 632 |
3 |
DL_TFC3 |
UL_TFC3 |
DL_TFC0, UL_TFC0 DL_TFC5 ,UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC3, UL_TFC5, UL_TFC8 |
RB5: 1784 |
RB5: 952 |
4 |
DL_TFC4 |
UL_TFC4 |
DL_TFC0, UL_TFC0 DL_TFC5 ,UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC4, UL_TFC5, UL_TFC9 |
RB5: 1272 |
RB5: 1272 |
NOTE 1: UL_TFC0, UL_TFC1 and UL_TFC5 are part of minimum set of TFCIs. NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs. For RB5: Test data size has been set to the payload size of the DL TF under test minus 8 bits (size of 7 bit length indicator and expansion bit). The UL RLC SDU size has been set equal to the size of the payload size of the UL TF under test minus 8 bits (the size of 7 bit length indicator and expansion bit). |
See 18.2.1.1 for test procedure.
18.2.2.23c.2.4 Test requirements
See 18.2.1.1 for definition of step 10 and step 15.
1. At step 10 the UE shall send a RADIO BEARER SETUP COMPLETE message.
2. At step 15 the UE transmitted transport format shall be
– for sub-test 1: RB5/TF1 (1×144).
– for sub-test 2: RB5/TF2 (5×144).
– for sub-test 3: RB5/TF2 (7×144).
– for sub-test 4: RB5/TF2 (10×144).
3. At step 15 the UE shall return
– for sub for sub-test 1: an RLC SDU on RB5 having the same content as 1 times plus 64 lsb’s of the DL RLC SDU sent by the SS.
– for sub-test 2: an RLC SDU on RB5 having the same content as sent by the SS.
– for sub-test 3: an RLC SDU on RB5 having the same content as 1 times plus 832 lsb’s of the DL RLC SDU sent by the SS.
– for sub-test 4: an RLC SDU on RB5 having the same content as sent by the SS.
18.2.2.23d Interactive or background / UL:32 DL:32 kbps / PS RAB (20 ms TTI) + UL:3.4 DL:3.4 kbps SRBs for DCCH.
18.2.2.23d.1 Interactive or background / UL:32 DL:32 kbps / PS RAB (20 ms TTI) + UL:3.4 DL:3.4 kbps SRBs for DCCH / Payload size 320.
18.2.2.23d.1.1 Conformance requirement
See 18.2.2.4.1.
18.2.2.23d.1.2 Test purpose
Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.10.3.4.1.23d, for the uplink payload size of 320 case.
18.2.2.23d.1.3 Method of test
Uplink TFS:
TFI |
RB5 (32 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x336 |
0x148 |
TF1, bits |
1×336 |
1×148 |
|
TF2, bits |
2×336 |
N/A |
Uplink TFCS:
TFCI |
(RB5, DCCH) |
UL_TFC0 |
(TF0, TF0) |
UL_TFC1 |
(TF1, TF0) |
UL_TFC2 |
(TF2, TF0) |
UL_TFC3 |
(TF0, TF1) |
UL_TFC4 |
(TF1, TF1) |
UL_TFC5 |
(TF2, TF1) |
Downlink TFS:
TFI |
RB5 (32 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x336 |
0x148 |
TF1, bits |
1×336 |
1×148 |
|
TF2, bits |
2×336 |
N/A |
Downlink TFCS:
TFCI |
(RB5, DCCH) |
DL_TFC0 |
(TF0, TF0) |
DL_TFC1 |
(TF1, TF0) |
DL_TFC2 |
(TF2, TF0) |
DL_TFC3 |
(TF0, TF1) |
DL_TFC4 |
(TF1, TF1) |
DL_TFC5 |
(TF2, TF1) |
Sub-tests:
Sub-test |
Downlink TFCS Under test |
Uplink TFCS Under test |
Implicitly tested |
Restricted UL TFCIs (note 1) |
UL RLC SDU size (bits) (note 2) |
Test data size (bits) (note 2) |
1 |
DL_TFC1 |
UL_TFC1 |
DL_TFC0, UL_TFC0 DL_TFC3,UL_TFC3 |
UL_TFC0, UL_TFC1, UL_TFC3, UL_TFC4 |
RB5: 312 |
RB5: 312 |
2 |
DL_TFC2 |
UL_TFC2 |
DL_TFC0, UL_TFC0 DL_TFC3 ,UL_TFC3 |
UL_TFC0, UL_TFC1,UL_TFC2, UL_TFC3, UL_TFC5 |
RB5: 632 |
RB5: 632 |
NOTE 1: UL_TFC0, UL_TFC1, and UL_TFC3 are part of minimum set of TFCIs. NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs. For RB5: Test data size has been set to the payload size of the DL TF under test minus 8 bits (size of 7 bit length indicator and expansion bit). The UL RLC SDU size has been set equal to the size of the payload size of the UL TF under test minus 8 bits (the size of 7 bit length indicator and expansion bit). |
See 18.2.1.1 for test procedure.
18.2.2.23d.1.4 Test requirements
See 18.2.1.1 for definition of step 10 and step 15.
1. At step 10 the UE shall send a RADIO BEARER SETUP COMPLETE message.
2. At step 15 the UE transmitted transport format shall be
– for sub-test 1: RB5/TF1 (1×336).
– for sub-test 2: RB5/TF2 (2×336).
3. At step 15 the UE shall return
– for sub-test 1 to 2: an RLC SDU on RB5 having the same content as the DL RLC SDU sent by the SS.
18.2.2.23d.2 Interactive or background / UL:32 DL:32 kbps / PS RAB (20 ms TTI) + UL:3.4 DL:3.4 kbps SRBs for DCCH / Payload size 128.
18.2.2.23d.2.1 Conformance requirement
See clause 18.2.2.4.1.
18.2.2.23d.2.2 Test purpose
Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.10.3.4.1.23d, for the uplink payload size 128 case.
18.2.2.23d.2.3 Method of test
Uplink TFS:
TFI |
RB5 (16 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x144 |
0x148 |
TF1, bits |
1×144 |
1×148 |
|
TF2, bits |
5×144 |
N/A |
Uplink TFCS:
TFCI |
(RB5, DCCH) |
UL_TFC0 |
(TF0, TF0) |
UL_TFC1 |
(TF1, TF0) |
UL_TFC2 |
(TF2, TF0) |
UL_TFC3 |
(TF0, TF1) |
UL_TFC4 |
(TF1, TF1) |
UL_TFC5 |
(TF2, TF1) |
Downlink TFS:
TFI |
RB5 (32 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x336 |
0x148 |
TF1, bits |
1×336 |
1×148 |
|
TF2, bits |
2×336 |
N/A |
Downlink TFCS:
TFCI |
(RB5, DCCH) |
DL_TFC0 |
(TF0, TF0) |
DL_TFC1 |
(TF1, TF0) |
DL_TFC2 |
(TF2, TF0) |
DL_TFC3 |
(TF0, TF1) |
DL_TFC4 |
(TF1, TF1) |
DL_TFC5 |
(TF2, TF1) |
Sub-tests:
Sub-test |
Downlink TFCS Under test |
Uplink TFCS Under test |
Implicitly tested |
Restricted UL TFCIs (note 1) |
UL RLC SDU size (bits) (note 2) |
Test data size (bits) (note 2) |
1 |
DL_TFC1 |
UL_TFC1 |
DL_TFC0, UL_TFC0 DL_TFC3,UL_TFC3 |
UL_TFC0, UL_TFC1, UL_TFC3, UL_TFC4 |
RB5: 376 |
RB5: 312 |
2 |
DL_TFC2 |
UL_TFC2 |
DL_TFC0, UL_TFC0 DL_TFC3 ,UL_TFC3 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3, UL_TFC5 |
RB5: 632 |
RB5: 632 |
NOTE 1: UL_TFC0, UL_TFC1 and UL_TFC3 are part of minimum set of TFCIs. NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs. |
See 18.2.1.1 for test procedure.
18.2.2.23d.2.4 Test requirements
See 18.2.1.1 for definition of step 10 and step 15.
1. At step 10 the UE shall send a RADIO BEARER SETUP COMPLETE message.
2. At step 15 the UE transmitted transport format shall be
– for sub-test 1: RB5/TF1 (1×144).
– for sub-test 2: RB5/TF2 (5×144).
3. At step 15 the UE shall return
– for sub-test 1: an RLC SDU on RB5 having the same content as 1 times plus 64 lsb’s of the DL RLC SDU sent by the SS.
– for sub-test 2: an RLC SDU on RB5 having the same content as sent by the SS.
18.2.2.24 Void
18.2.2.25 Interactive or background / UL:32 DL: 64 kbps / PS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH
18.2.2.25.1 Interactive or background / UL:32 DL: 64 kbps / PS RAB / Payload size 320
18.2.2.25.1.1 Conformance requirement
See 18.2.2.4.1.
18.2.2.25.1.2 Test purpose
Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.10.3.4.1.25 for the uplink payload size of 320 case.
18.2.2.25.1.3 Method of test
Uplink TFS:
TFI |
RB5 (32 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x336 |
0x148 |
TF1, bits |
1×336 |
1×148 |
|
TF2, bits |
2×336 |
N/A |
Uplink TFCS:
TFCI |
(RB5, DCCH) |
UL_TFC0 |
(TF0, TF0) |
UL_TFC1 |
(TF1, TF0) |
UL_TFC2 |
(TF2, TF0) |
UL_TFC3 |
(TF0, TF1) |
UL_TFC4 |
(TF1, TF1) |
UL_TFC5 |
(TF2, TF1) |
Downlink TFS:
TFI |
RB5 (64 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x336 |
0x148 |
TF1, bits |
1×336 |
1×148 |
|
TF2, bits |
2×336 |
N/A |
|
TF3, bits |
3×336 |
N/A |
|
TF4, bits |
4×336 |
N/A |
Downlink TFCS:
TFCI |
(RB5, DCCH) |
DL_TFC0 |
(TF0, TF0) |
DL_TFC1 |
(TF1, TF0) |
DL_TFC2 |
(TF2, TF0) |
DL_TFC3 |
(TF3, TF0) |
DL_TFC4 |
(TF4, TF0) |
DL_TFC5 |
(TF0, TF1) |
DL_TFC6 |
(TF1, TF1) |
DL_TFC7 |
(TF2, TF1) |
DL_TFC8 |
(TF3, TF1) |
DL_TFC9 |
(TF4, TF1) |
Sub-tests:
Sub-test |
Downlink TFCS Under test |
Uplink TFCS Under test |
Implicitly tested |
Restricted UL TFCIs (note 1) |
UL RLC SDU size (bits) (note 2) |
Test data size (bits) (note 2) |
1 |
DL_TFC1 |
UL_TFC1 |
DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC3 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3 |
RB5: 312 |
RB5: 312 |
2 |
DL_TFC2 |
UL_TFC2 |
DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC3 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3, UL_TFC5 |
RB5: 632 |
RB5: 632 |
3 |
DL_TFC3 |
UL_TFC1 |
DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC3 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3 |
RB5: 952 |
RB5: 952 |
4 |
DL_TFC4 |
UL_TFC2 |
DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC3 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3, UL_TFC5 |
RB5: 1272 |
RB5: 1272 |
NOTE 1: UL_TFC0, UL_TFC1, and UL_TFC3 are part of minimum set of TFCIs. NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs. |
See 18.2.1.1 for test procedure.
18.2.2.25.1.4 Test requirements
See 18.2.1.1 for definition of step 10 and step 15.
1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.
2. At step 15 the UE transmitted transport format shall be
– for sub-test 1 and 3: RB5/TF1 (1×336).
– for sub-test 2 and 4: RB5/TF1 (2×336).
3. At step 15 the UE shall return
– for sub-test 1 to 4: an RLC SDU on RB5 having the same content as the DL RLC SDU sent by the SS.
18.2.2.25.2 Interactive or background / UL:32 DL: 64 kbps / PS RAB / Payload 128
18.2.2.25.2.1 Conformance requirement
See 18.2.2.4.1.
18.2.2.25.2.2 Test purpose
Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.10.3.4.1.25 for the uplink payload 128 case.
18.2.2.25.2.3 Method of test
Uplink TFS:
TFI |
RB5 (32 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x144 |
0x148 |
TF1, bits |
1×144 |
1×148 |
|
TF2, bits |
5×144 |
N/A |
Uplink TFCS:
TFCI |
(RB5, DCCH) |
UL_TFC0 |
(TF0, TF0) |
UL_TFC1 |
(TF1, TF0) |
UL_TFC2 |
(TF2, TF0) |
UL_TFC3 |
(TF0, TF1) |
UL_TFC4 |
(TF1, TF1) |
UL_TFC5 |
(TF2, TF1) |
Downlink TFS:
TFI |
RB5 (64 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x336 |
0x148 |
TF1, bits |
1×336 |
1×148 |
|
TF2, bits |
2×336 |
N/A |
|
TF3, bits |
3×336 |
N/A |
|
TF4, bits |
4×336 |
N/A |
Downlink TFCS:
TFCI |
(RB5, DCCH) |
DL_TFC0 |
(TF0, TF0) |
DL_TFC1 |
(TF1, TF0) |
DL_TFC2 |
(TF2, TF0) |
DL_TFC3 |
(TF3, TF0) |
DL_TFC4 |
(TF4, TF0) |
DL_TFC5 |
(TF0, TF1) |
DL_TFC6 |
(TF1, TF1) |
DL_TFC7 |
(TF2, TF1) |
DL_TFC8 |
(TF3, TF1) |
DL_TFC9 |
(TF4, TF1) |
Sub-tests:
Sub-test |
Downlink TFCS Under test |
Uplink TFCS Under test |
Implicitly tested |
Restricted UL TFCIs (note 1) |
UL RLC SDU size (bits) (note 2) |
Test data size (bits) (note 2) |
1 |
DL_TFC1 |
UL_TFC1 |
DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC3 |
UL_TFC0, UL_TFC1, UL_TFC3, UL_TFC4 |
RB5: 376 |
RB5: 312 |
2 |
DL_TFC2 |
UL_TFC2 |
DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC3 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3, UL_TFC5 |
RB5: 632 |
RB5: 632 |
3 |
DL_TFC3 |
UL_TFC1 |
DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC3 |
UL_TFC0, UL_TFC1, UL_TFC3, UL_TFC4 |
RB5: 1016 |
RB5: 952 |
4 |
DL_TFC4 |
UL_TFC2 |
DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC3 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3, UL_TFC5 |
RB5: 1272 |
RB5: 1272 |
NOTE 1: UL_TFC0, UL_TFC1, and UL_TFC3 are part of minimum set of TFCIs. NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs. |
See 18.2.1.1 for test procedure.
18.2.2.25.2.4 Test requirements
See 18.2.1.1 for definition of step 10 and step 15.
1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.
2. At step 15 the UE transmitted transport format shall be
– for sub-test 1: RB5/TF1 (1×144).
– for sub-test 2: RB5/TF2 (5×144).
– for sub-test 3: RB5/TF1 (1×144).
– for sub-test 4: RB5/TF2 (5×144).
3. At step 15 the UE shall return
– for sub-test 1: an RLC SDU on RB5 having the same content as 1 times plus 64 lsb’s of the DL RLC SDU sent by the SS.
– for sub-test 2: an RLC SDU on RB5 having the same content as the DL RLC SDU sent by the SS.
– for sub-test 3: an RLC SDU on RB5 having the same content as 1 times plus 64 lsb’s of the DL RLC SDU sent by the SS.
– for sub-test 4: an RLC SDU on RB5 having the same content as the DL RLC SDU sent by the SS.
18.2.2.26 Interactive or background / UL:64 DL: 64 kbps / PS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH
18.2.2.26.1 Interactive or background / UL:64 DL: 64 kbps / PS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH / Payload 320, Physical Configuration 1
18.2.2.26.1.1 Conformance requirement
See 18.2.2.4.1.
18.2.2.26.1.2 Test purpose
Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.10.3.4.1.26 for the uplink payload 320 case with physical configuration 1.
18.2.2.26.1.3 Method of test
Uplink TFS:
TFI |
RB5 (64 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x336 |
0x148 |
TF1, bits |
1×336 |
1×148 |
|
TF2, bits |
2×336 |
N/A |
|
TF3, bits |
3×336 |
N/A |
|
TF4, bits |
4×336 |
N/A |
Uplink TFCS:
TFCI |
(RB5, DCCH) |
UL_TFC0 |
(TF0, TF0) |
UL_TFC1 |
(TF1, TF0) |
UL_TFC2 |
(TF2, TF0) |
UL_TFC3 |
(TF3, TF0) |
UL_TFC4 |
(TF4, TF0) |
UL_TFC5 |
(TF0, TF1) |
UL_TFC6 |
(TF1, TF1) |
UL_TFC7 |
(TF2, TF1) |
UL_TFC8 |
(TF3, TF1) |
UL_TFC9 |
(TF4, TF1) |
Physical channel parameters
DPCH Uplink |
Physical Configuration 1 |
|
Midamble |
512 chips |
|
Codes and time slots |
SF16 x 1 code x 1 time slot + SF4 x 1 code x 1 time slot |
|
Max. Number of data bits/radio frame |
1148 bits |
|
TFCI code word |
16 bits |
|
TPC |
2 bits |
|
Puncturing Limit |
0.48 (alt. 0.44) |
Downlink TFS:
TFI |
RB5 (64 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x336 |
0x148 |
TF1, bits |
1×336 |
1×148 |
|
TF2, bits |
2×336 |
N/A |
|
TF3, bits |
3×336 |
N/A |
|
TF4, bits |
4×336 |
N/A |
Downlink TFCS:
TFCI |
(RB5, DCCH) |
DL_TFC0 |
(TF0, TF0) |
DL_TFC1 |
(TF1, TF0) |
DL_TFC2 |
(TF2, TF0) |
DL_TFC3 |
(TF3, TF0) |
DL_TFC4 |
(TF4, TF0) |
DL_TFC5 |
(TF0, TF1) |
DL_TFC6 |
(TF1, TF1) |
DL_TFC7 |
(TF2, TF1) |
DL_TFC8 |
(TF3, TF1) |
DL_TFC9 |
(TF4, TF1) |
Sub-tests:
Sub-test |
Downlink TFCS Under test |
Uplink TFCS Under test |
Implicitly tested |
Restricted UL TFCIs (note 1) |
UL RLC SDU size (bits) (note 2) |
Test data size (bits) (note 2) |
1 |
DL_TFC1 |
UL_TFC1 |
DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC5, UL_TFC6 |
RB5: 312 |
RB5: 312 |
2 |
DL_TFC2 |
UL_TFC2 |
DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC5, UL_TFC7 |
RB5: 632 |
RB5: 632 |
3 |
DL_TFC3 |
UL_TFC3 |
DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC3, UL_TFC5, UL_TFC8 |
RB5: 952 |
RB5: 952 |
4 |
DL_TFC4 |
UL_TFC4 |
DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC4, UL_TFC5, UL_TFC9 |
RB5: 1272 |
RB5: 1272 |
NOTE 1: UL_TFC0, UL_TFC1 and UL_TFC5 are part of minimum set of TFCIs. NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs. |
See 18.2.1.1 for test procedure.
18.2.2.26.1.4 Test requirements
See 18.2.1.1 for definition of step 10 and step 15.
1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.
2. At step 15 the UE transmitted transport format shall be
– for sub-test 1: RB5/TF1 (1×336).
– for sub-test 2: RB5/TF2 (2×336) or RB5/TF1 (1×336).
– for sub-test 3: RB5/TF3 (3×336) or RB5/TF1 (1×336).
– for sub-test 4: RB5/TF4 (4×336) or RB5/TF1 (1×336).
3. At step 15 the UE shall return
– for sub-test 1 to 4: an RLC SDU on RB5 having the same content as the DL RLC SDU sent by the SS.
18.2.2.26.2 Interactive or background / UL:64 DL: 64 kbps / PS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH / Payload 128, Physical Configuration 2
18.2.2.26.2.1 Conformance requirement
See 18.2.2.4.1.
18.2.2.26.2.2 Test purpose
Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.10.3.4.1.26 for the uplink payload 128 case with physical configuration 2.
18.2.2.26.2.3 Method of test
Uplink TFS:
TFI |
RB5 (64 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x144 |
0x148 |
TF1, bits |
1×144 |
1×148 |
|
TF2, bits |
3×144 |
N/A |
|
TF3, bits |
7×144 |
N/A |
|
TF4, bits |
10×144 |
N/A |
Uplink TFCS:
TFCI |
(RB5, DCCH) |
UL_TFC0 |
(TF0, TF0) |
UL_TFC1 |
(TF1, TF0) |
UL_TFC2 |
(TF2, TF0) |
UL_TFC3 |
(TF3, TF0) |
UL_TFC4 |
(TF4, TF0) |
UL_TFC5 |
(TF0, TF1) |
UL_TFC6 |
(TF1, TF1) |
UL_TFC7 |
(TF2, TF1) |
UL_TFC8 |
(TF3, TF1) |
UL_TFC9 |
(TF4, TF1) |
Physical channel parameters
DPCH Uplink |
Physical Configuration 2 |
|
Midamble |
512 chips |
|
Codes and time slots |
SF2 x 1 code x 1 time slot + SF4 x 1 code x 1 time slot |
|
Max. Number of data bits/radio frame |
2784 bits |
|
TFCI code word |
16 bits |
|
TPC |
2 bits |
|
Puncturing Limit |
1 |
Downlink TFS:
TFI |
RB5 (64 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x336 |
0x148 |
TF1, bits |
1×336 |
1×148 |
|
TF2, bits |
2×336 |
N/A |
|
TF3, bits |
3×336 |
N/A |
|
TF4, bits |
4×336 |
N/A |
Downlink TFCS:
TFCI |
(RB5, DCCH) |
DL_TFC0 |
(TF0, TF0) |
DL_TFC1 |
(TF1, TF0) |
DL_TFC2 |
(TF2, TF0) |
DL_TFC3 |
(TF3, TF0) |
DL_TFC4 |
(TF4, TF0) |
DL_TFC5 |
(TF0, TF1) |
DL_TFC6 |
(TF1, TF1) |
DL_TFC7 |
(TF2, TF1) |
DL_TFC8 |
(TF3, TF1) |
DL_TFC9 |
(TF4, TF1) |
Sub-tests:
Sub-test |
Downlink TFCS Under test |
Uplink TFCS Under test |
Implicitly tested |
Restricted UL TFCIs (note 1) |
UL RLC SDU size (bits) (note 2) |
Test data size (bits) (note 2) |
1 |
DL_TFC1 |
UL_TFC1 |
DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC5, UL_TFC6 |
RB5: 376 |
RB5: 312 |
2 |
DL_TFC2 |
UL_TFC2 |
DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC5, UL_TFC7 |
RB5: 760 |
RB5: 632 |
3 |
DL_TFC3 |
UL_TFC3 |
DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC3, UL_TFC5, UL_TFC8 |
RB5: 1784 |
RB5: 952 |
4 |
DL_TFC4 |
UL_TFC4 |
DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC4, UL_TFC5, UL_TFC9 |
RB5: 1272 |
RB5: 1272 |
NOTE 1: UL_TFC0, UL_TFC1 and UL_TFC5 are part of minimum set of TFCIs. NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs. |
See 18.2.1.1 for test procedure.
18.2.2.26.2.4 Test requirements
See 18.2.1.1 for definition of step 10 and step 15.
1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.
2. At step 15 the UE transmitted transport format shall be
– for sub-test 1: RB5/TF1 (1×144).
– for sub-test 2: RB5/TF2 (3×144).
– for sub-test 3: RB5/TF3 (7×144).
– for sub-test 4: RB5/TF4 (10×144).
3. At step 15 the UE shall return
– for sub-test 1: an RLC SDU on RB5 having the same content as 1 times plus 64 lsb’s of the DL RLC SDU sent by the SS.
– for sub-test 2: an RLC SDU on RB5 having the same content as 1 times plus 128 lsb’s of the DL RLC SDU sent by the SS.
– for sub-test 3: an RLC SDU on RB5 having the same content as 1 times plus 832 lsb’s of the DL RLC SDU sent by the SS.
– for sub-test 4: an RLC SDU on RB5 having the same content as the DL RLC SDU sent by the SS.
18.2.2.27 Interactive or background / UL:64 DL:128 kbps / PS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH
18.2.2.27.1 Interactive or background / UL:64 DL:128 kbps / PS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH / Payload 320, Physical Configuration 1
18.2.2.27.1.1 Conformance requirement
See 18.2.2.4.1.
18.2.2.27.1.2 Test purpose
Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.10.3.4.1.27 for the uplink payload 320 case with physical configuration 1.
18.2.2.27.1.3 Method of test
Uplink TFS:
TFI |
RB5 (64 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x336 |
0x148 |
TF1, bits |
1×336 |
1×148 |
|
TF2, bits |
2×336 |
N/A |
|
TF3, bits |
3×336 |
N/A |
|
TF4, bits |
4×336 |
N/A |
Uplink TFCS:
TFCI |
(RB5, DCCH) |
UL_TFC0 |
(TF0, TF0) |
UL_TFC1 |
(TF1, TF0) |
UL_TFC2 |
(TF2, TF0) |
UL_TFC3 |
(TF3, TF0) |
UL_TFC4 |
(TF4, TF0) |
UL_TFC5 |
(TF0, TF1) |
UL_TFC6 |
(TF1, TF1) |
UL_TFC7 |
(TF2, TF1) |
UL_TFC8 |
(TF3, TF1) |
UL_TFC9 |
(TF4, TF1) |
Physical channel parameters
DPCH Uplink |
Physical Configuration 1 |
|
Midamble |
512 chips |
|
Codes and time slots |
SF16 x 1 code x 1 time slot + SF4 x 1 code x 1 time slot |
|
Max. Number of data bits/radio frame |
1148 bits |
|
TFCI code word |
16 bits |
|
TPC |
2 bits |
|
Puncturing Limit |
0.48 (alt. 0.44) |
Downlink TFS:
TFI |
RB5 (128 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x336 |
0x148 |
TF1, bits |
1×336 |
1×148 |
|
TF2, bits |
2×336 |
N/A |
|
TF3, bits |
4×336 |
N/A |
|
TF4, bits |
8×336 |
N/A |
Downlink TFCS:
TFCI |
(RB5, DCCH) |
DL_TFC0 |
(TF0, TF0) |
DL_TFC1 |
(TF1, TF0) |
DL_TFC2 |
(TF2, TF0) |
DL_TFC3 |
(TF3, TF0) |
DL_TFC4 |
(TF4, TF0) |
DL_TFC5 |
(TF0, TF1) |
DL_TFC6 |
(TF1, TF1) |
DL_TFC7 |
(TF2, TF1) |
DL_TFC8 |
(TF3, TF1) |
DL_TFC9 |
(TF4, TF1) |
Physical channel parameters
DPCH Downlink |
Physical Configuration 1 |
|
Midamble |
256 chips |
|
Codes and time slots |
SF16 x 8 codes x 1 time slot |
|
Max. Number of data bits/radio frame |
2192 bits |
|
TFCI code word |
16 bits |
|
Puncturing limit |
0.48 |
Sub-tests:
Sub-test |
Downlink TFCS Under test |
Uplink TFCS Under test |
Implicitly tested |
Restricted UL TFCIs (note 1) |
UL RLC SDU size (bits) (note 2) |
Test data size (bits) (note 2) |
1 |
DL_TFC1 |
UL_TFC1 |
DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC5, UL_TFC6 |
RB5: 312 |
RB5: 312 |
2 |
DL_TFC2 |
UL_TFC2 |
DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC5, UL_TFC7 |
RB5: 632 |
RB5: 632 |
3 |
DL_TFC3 |
UL_TFC3 |
DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC3, UL_TFC5, UL_TFC8 |
RB5: 1912 |
RB5: 1272 |
4 |
DL_TFC4 |
UL_TFC4 |
DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC4, UL_TFC5, UL_TFC9 |
RB5: 2552 |
RB5: 2552 |
NOTE 1: UL_TFC0, UL_TFC1, and UL_TFC5 are part of minimum set of TFCIs. NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs. |
See 18.2.1.1 for test procedure.
18.2.2.27.1.4 Test requirements
See 18.2.1.1 for definition of step 10 and step 15.
1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.
2. At step 15 the UE transmitted transport format shall be
– for sub-test 1: RB5/TF1 (1×336).
– for sub-test 2: RB5/TF2 (2×336) or RB5/TF1 (1×336).
– for sub-test 3: RB5/TF3 (3×336) or RB5/TF1 (1×336).
– for sub-test 4: RB5/TF4 (4×336) or RB5/TF1 (1×336).
3. At step 15 the UE shall return
– for sub-test 1, 2 and 4: an RLC SDU on RB5 having the same content as the DL RLC SDU sent by the SS.
– for sub-test 3: an RLC SDU on RB5 having the same content as 1 times plus 640 lsb’s of the DL RLC SDU sent by the SS.
18.2.2.27.2 Interactive or background / UL:64 DL:128 kbps / PS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH / Payload 128, Physical Configuration 2
18.2.2.27.2.1 Conformance requirement
See 18.2.2.4.1.
18.2.2.27.2.2 Test purpose
Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.10.3.4.1.27 for the uplink payload 128 case with physical configuration 2.
18.2.2.27.2.3 Method of test
Uplink TFS:
TFI |
RB5 (64 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x144 |
0x148 |
TF1, bits |
1×144 |
1×148 |
|
TF2, bits |
3×144 |
N/A |
|
TF3, bits |
7×144 |
N/A |
|
TF4, bits |
10×144 |
N/A |
Uplink TFCS:
TFCI |
(RB5, DCCH) |
UL_TFC0 |
(TF0, TF0) |
UL_TFC1 |
(TF1, TF0) |
UL_TFC2 |
(TF2, TF0) |
UL_TFC3 |
(TF3, TF0) |
UL_TFC4 |
(TF4, TF0) |
UL_TFC5 |
(TF0, TF1) |
UL_TFC6 |
(TF1, TF1) |
UL_TFC7 |
(TF2, TF1) |
UL_TFC8 |
(TF3, TF1) |
UL_TFC9 |
(TF4, TF1) |
Physical channel parameters
DPCH Uplink |
Physical Configuration 2 |
|
Midamble |
512 chips |
|
Codes and time slots |
SF2 x 1 code x 1 time slot + SF4 x 1 code x 1 time slot |
|
Max. Number of data bits/radio frame |
2784 bits |
|
TFCI code word |
16 bits |
|
TPC |
2 bits |
|
Puncturing Limit |
1 |
Downlink TFS:
TFI |
RB5 (128 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x336 |
0x148 |
TF1, bits |
1×336 |
1×148 |
|
TF2, bits |
2×336 |
N/A |
|
TF3, bits |
4×336 |
N/A |
|
TF4, bits |
8×336 |
N/A |
Downlink TFCS:
TFCI |
(RB5, DCCH) |
DL_TFC0 |
(TF0, TF0) |
DL_TFC1 |
(TF1, TF0) |
DL_TFC2 |
(TF2, TF0) |
DL_TFC3 |
(TF3, TF0) |
DL_TFC4 |
(TF4, TF0) |
DL_TFC5 |
(TF0, TF1) |
DL_TFC6 |
(TF1, TF1) |
DL_TFC7 |
(TF2, TF1) |
DL_TFC8 |
(TF3, TF1) |
DL_TFC9 |
(TF4, TF1) |
Physical channel parameters
DPCH Downlink |
Physical Configuration 2 |
|
Midamble |
256 chips |
|
Codes and time slots |
SF16 x 4 codes x 2 time slots + SF16 x 3 codes x 2 time slots |
|
Max. Number of data bits/radio frame |
3848 bits |
|
TFCI code word |
16 bits |
|
Puncturing limit |
0.84 |
Sub-tests:
Sub-test |
Downlink TFCS Under test |
Uplink TFCS Under test |
Implicitly tested |
Restricted UL TFCIs (note 1) |
UL RLC SDU size (bits) (note 2) |
Test data size (bits) (note 2) |
1 |
DL_TFC1 |
UL_TFC1 |
DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC5, UL_TFC6 |
RB5: 376 |
RB5: 312 |
2 |
DL_TFC2 |
UL_TFC2 |
DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC5, UL_TFC7 |
RB5: 760 |
RB5: 632 |
3 |
DL_TFC3 |
UL_TFC3 |
DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC3, UL_TFC5, UL_TFC8 |
RB5: 1784 |
RB5: 1272 |
4 |
DL_TFC4 |
UL_TFC4 |
DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC4, UL_TFC5, UL_TFC9 |
RB5: 2552 |
RB5: 2552 |
NOTE 1: UL_TFC0, UL_TFC1, and UL_TFC5 are part of minimum set of TFCIs. NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs. |
See 18.2.1.1 for test procedure.
18.2.2.27.2.4 Test requirements
See 18.2.1.1 for definition of step 10 and step 15.
1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.
2. At step 15 the UE transmitted transport format shall be
– for sub-test 1: RB5/TF1 (1×144).
– for sub-test 2: RB5/TF2 (3×144).
– for sub-test 3: RB5/TF3 (7×144).
– for sub-test 4: RB5/TF4 (10×144).
3. At step 15 the UE shall return
– for sub-test 1: an RLC SDU on RB5 having the same content as 1 times plus 64 lsb’s of the DL RLC SDU sent by the SS.
– for sub-test 2: an RLC SDU on RB5 having the same content as 1 times plus 128 lsb’s of the DL RLC SDU sent by the SS.
– for sub-test 3: an RLC SDU on RB5 having the same content as 1 times plus 512 lsb’s of the DL RLC SDU sent by the SS.
– for sub-test 4: an RLC SDU on RB5 having the same content as the DL RLC SDU sent by the SS.
18.2.2.28 Interactive or background / UL:128 DL:128 kbps / PS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH
18.2.2.28.1 Interactive or background / UL:128 DL:128 kbps / PS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH / Payload 320, Physical Configuration 1
18.2.2.28.1.1 Conformance requirement
See 18.2.2.4.1.
18.2.2.28.1.2 Test purpose
Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.10.3.4.1.28 for the uplink payload 320 case with physical configuration 1.
18.2.2.28.1.3 Method of test
Uplink TFS:
TFI |
RB5 (128 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x336 |
0x148 |
TF1, bits |
1×336 |
1×148 |
|
TF2, bits |
2×336 |
N/A |
|
TF3, bits |
4×336 |
N/A |
|
TF4, bits |
8×336 |
N/A |
Uplink TFCS:
TFCI |
(RB5, DCCH) |
UL_TFC0 |
(TF0, TF0) |
UL_TFC1 |
(TF1, TF0) |
UL_TFC2 |
(TF2, TF0) |
UL_TFC3 |
(TF3, TF0) |
UL_TFC4 |
(TF4, TF0) |
UL_TFC5 |
(TF0, TF1) |
UL_TFC6 |
(TF1, TF1) |
UL_TFC7 |
(TF2, TF1) |
UL_TFC8 |
(TF3, TF1) |
UL_TFC9 |
(TF4, TF1) |
Physical channel parameters
DPCH Uplink |
Physical Configuration 1 |
|
Midamble |
256 chips |
|
Codes and time slots |
SF2 x 1 code x 1 timeslot |
|
Max. Number of data bits/radio frame |
2064 bits |
|
TFCI code word |
16 bits |
|
TPC |
2 bits |
|
Puncturing Limit |
0.44 (alt. 0.40) |
Downlink TFS:
TFI |
RB5 (128 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x336 |
0x148 |
TF1, bits |
1×336 |
1×148 |
|
TF2, bits |
2×336 |
N/A |
|
TF3, bits |
4×336 |
N/A |
|
TF4, bits |
8×336 |
N/A |
Downlink TFCS:
TFCI |
(RB5, DCCH) |
DL_TFC0 |
(TF0, TF0) |
DL_TFC1 |
(TF1, TF0) |
DL_TFC2 |
(TF2, TF0) |
DL_TFC3 |
(TF3, TF0) |
DL_TFC4 |
(TF4, TF0) |
DL_TFC5 |
(TF0, TF1) |
DL_TFC6 |
(TF1, TF1) |
DL_TFC7 |
(TF2, TF1) |
DL_TFC8 |
(TF3, TF1) |
DL_TFC9 |
(TF4, TF1) |
Physical channel parameters
DPCH Downlink |
Physical Configuration 1 |
|
Midamble |
256 chips |
|
Codes and time slots |
SF16 x 8 codes x 1 time slot |
|
Max. Number of data bits/radio frame |
2192 bits |
|
TFCI code word |
16 bits |
|
Puncturing limit |
0.48 |
Sub-tests:
Sub-test |
Downlink TFCS Under test |
Uplink TFCS Under test |
Implicitly tested |
Restricted UL TFCIs (note 1) |
UL RLC SDU size (bits) (note 2) |
Test data size (bits) (note 2) |
1 |
DL_TFC1 |
UL_TFC1 |
DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC5, UL_TFC6 |
RB5: 312 |
RB5: 312 |
2 |
DL_TFC2 |
UL_TFC2 |
DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC5, UL_TFC7 |
RB5: 632 |
RB5: 632 |
3 |
DL_TFC3 |
UL_TFC3 |
DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC3, UL_TFC5, UL_TFC8 |
RB5: 1272 |
RB5: 1272 |
4 |
DL_TFC4 |
UL_TFC4 |
DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC4, UL_TFC5, UL_TFC9 |
RB5: 2552 |
RB5: 2552 |
NOTE 1: UL_TFC0, UL_TFC1, and UL_TFC5 are part of minimum set of TFCIs. NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs. |
See 18.2.1.1 for test procedure.
18.2.2.28.1.4 Test requirements
See 18.2.1.1 for definition of step 10 and step 15.
1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.
2. At step 15 the UE transmitted transport format shall be
– for sub-test 1: RB5/TF1 (1×336).
– for sub-test 2: RB5/TF2 (2×336).
– for sub-test 3: RB5/TF3 (4×336).
– for sub-test 4: RB5/TF4 (8×336).
3. At step 15 the UE shall return
– for sub-test 1 to 4: an RLC SDU on RB5 having the same content as the DL RLC SDU sent by the SS.
18.2.2.28.2 Interactive or background / UL:128 DL:128 kbps / PS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH / Payload 128, Physical Configuration 2
18.2.2.28.2.1 Conformance requirement
See 18.2.2.4.1.
18.2.2.28.2.2 Test purpose
Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.10.3.4.1.28 for the uplink payload 128 case with physical configuration 2.
18.2.2.28.2.3 Method of test
Uplink TFS:
TFI |
RB5 (128 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x144 |
0x148 |
TF1, bits |
1×144 |
1×148 |
|
TF2, bits |
7×144 |
N/A |
|
TF3, bits |
14×144 |
N/A |
|
TF4, bits |
20×144 |
N/A |
Uplink TFCS:
TFCI |
(RB5, DCCH) |
UL_TFC0 |
(TF0, TF0) |
UL_TFC1 |
(TF1, TF0) |
UL_TFC2 |
(TF2, TF0) |
UL_TFC3 |
(TF3, TF0) |
UL_TFC4 |
(TF4, TF0) |
UL_TFC5 |
(TF0, TF1) |
UL_TFC6 |
(TF1, TF1) |
UL_TFC7 |
(TF2, TF1) |
UL_TFC8 |
(TF3, TF1) |
UL_TFC9 |
(TF4, TF1) |
Physical channel parameters
DPCH Uplink |
Physical Configuration 2 |
|
Midamble |
256 chips |
|
Codes and time slots |
SF2 x 1 code x 2 timeslots + SF4 x 1 code x 1 time slot |
|
Max. Number of data bits/radio frame |
5376 bits |
|
TFCI code word |
16 bits |
|
TPC |
2 bits |
|
Puncturing Limit |
1 |
Downlink TFS:
TFI |
RB5 (128 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x336 |
0x148 |
TF1, bits |
1×336 |
1×148 |
|
TF2, bits |
2×336 |
N/A |
|
TF3, bits |
4×336 |
N/A |
|
TF4, bits |
8×336 |
N/A |
Downlink TFCS:
TFCI |
(RB5, DCCH) |
DL_TFC0 |
(TF0, TF0) |
DL_TFC1 |
(TF1, TF0) |
DL_TFC2 |
(TF2, TF0) |
DL_TFC3 |
(TF3, TF0) |
DL_TFC4 |
(TF4, TF0) |
DL_TFC5 |
(TF0, TF1) |
DL_TFC6 |
(TF1, TF1) |
DL_TFC7 |
(TF2, TF1) |
DL_TFC8 |
(TF3, TF1) |
DL_TFC9 |
(TF4, TF1) |
Physical channel parameters
DPCH Downlink |
Physical Configuration 2 |
|
Midamble |
256 chips |
|
Codes and time slots |
SF16 x 4 codes x 2 time slots + SF16 x 3 codes x 2 time slots |
|
Max. Number of data bits/radio frame |
3848 bits |
|
TFCI code word |
16 bits |
|
Puncturing limit |
0.84 |
Sub-tests:
Sub-test |
Downlink TFCS Under test |
Uplink TFCS Under test |
Implicitly tested |
Restricted UL TFCIs (note 1) |
UL RLC SDU size (bits) (note 2) |
Test data size (bits) (note 2) |
1 |
DL_TFC1 |
UL_TFC1 |
DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC5, UL_TFC6 |
RB5: 376 |
RB5: 312 |
2 |
DL_TFC2 |
UL_TFC2 |
DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC5, UL_TFC7 |
RB5: 888 |
RB5: 632 |
3 |
DL_TFC3 |
UL_TFC3 |
DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC3, UL_TFC5, UL_TFC8 |
RB5: 1784 |
RB5: 1272 |
4 |
DL_TFC4 |
UL_TFC4 |
DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC4, UL_TFC5, UL_TFC9 |
RB5: 2552 |
RB5: 2552 |
NOTE 1: UL_TFC0, UL_TFC1, and UL_TFC5 are part of minimum set of TFCIs. NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs. |
See 18.2.1.1 for test procedure.
18.2.2.28.2.4 Test requirements
See 18.2.1.1 for definition of step 10 and step 15.
1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.
2. At step 15 the UE transmitted transport format shall be
– for sub-test 1: RB5/TF1 (1×144).
– for sub-test 2: RB5/TF2 (7×144).
– for sub-test 3: RB5/TF3 (14×144).
– for sub-test 4: RB5/TF4 (20×144).
3. At step 15 the UE shall return
– for sub-test 1: an RLC SDU on RB5 having the same content as 1 times plus 64 lsb’s of the DL RLC SDU sent by the SS.
– for sub-test 2: an RLC SDU on RB5 having the same content as 1 times plus 256 lsb’s of the DL RLC SDU sent by the SS.
– for sub-test 3: an RLC SDU on RB5 having the same content as 1 times plus 512 lsb’s of the DL RLC SDU sent by the SS.
– for sub-test 4: an RLC SDU on RB5 having the same content as the DL RLC SDU sent by the SS.
18.2.2.29 Interactive or background / UL:64 DL:144 kbps / PS RAB + UL:3.4 DL: 3.4 kbps SRBs for DCCH
18.2.2.29.1 Interactive or background / UL:64 DL:144 kbps / PS RAB + UL:3.4 DL: 3.4 kbps SRBs for DCCH / Payload 320
18.2.2.29.1.1 Conformance requirement
See 18.2.2.4.1.
18.2.2.29.1.2 Test purpose
Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.10.3.4.1.29 for the uplink payload 320 case with physical configuration 1.
18.2.2.29.1.3 Method of test
Uplink TFS:
TFI |
RB5 (64 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x336 |
0x148 |
TF1, bits |
1×336 |
1×148 |
|
TF2, bits |
2×336 |
N/A |
|
TF3, bits |
3×336 |
N/A |
|
TF4, bits |
4×336 |
N/A |
Uplink TFCS:
TFCI |
(RB5, DCCH) |
UL_TFC0 |
(TF0, TF0) |
UL_TFC1 |
(TF1, TF0) |
UL_TFC2 |
(TF2, TF0) |
UL_TFC3 |
(TF3, TF0) |
UL_TFC4 |
(TF4, TF0) |
UL_TFC5 |
(TF0, TF1) |
UL_TFC6 |
(TF1, TF1) |
UL_TFC7 |
(TF2, TF1) |
UL_TFC8 |
(TF3, TF1) |
UL_TFC9 |
(TF4, TF1) |
Physical channel parameters
DPCH Uplink |
Physical Configuration 1 |
|
Midamble |
512 chips |
|
Codes and time slots |
SF16 x 1 code x 1 time slot + SF4 x 1 code x 1 time slot |
|
Max. Number of data bits/radio frame |
1148 bits |
|
TFCI code word |
16 bits |
|
TPC |
2 bits |
|
Puncturing Limit |
0.48 (alt. 0.44) |
Downlink TFS:
TFI |
RB5 (144 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x336 |
0x148 |
TF1, bits |
1×336 |
1×148 |
|
TF2, bits |
2×336 |
N/A |
|
TF3, bits |
4×336 |
N/A |
|
TF4, bits |
8×336 |
N/A |
|
TF5, bits |
9×336 |
N/A |
Downlink TFCS:
TFCI |
(RB5, DCCH) |
DL_TFC0 |
(TF0, TF0) |
DL_TFC1 |
(TF1, TF0) |
DL_TFC2 |
(TF2, TF0) |
DL_TFC3 |
(TF3, TF0) |
DL_TFC4 |
(TF4, TF0) |
DL_TFC5 |
(TF5, TF0) |
DL_TFC6 |
(TF0, TF1) |
DL_TFC7 |
(TF1, TF1) |
DL_TFC8 |
(TF2, TF1) |
DL_TFC9 |
(TF3, TF1) |
DL_TFC10 |
(TF4, TF1) |
DL_TFC11 |
(TF5, TF1) |
Sub-tests:
Sub-test |
Downlink TFCS Under test |
Uplink TFCS Under test |
Implicitly tested |
Restricted UL TFCIs (note 1) |
UL RLC SDU size (bits) (note 2) |
Test data size (bits) (note 2) |
1 |
DL_TFC1 |
UL_TFC1 |
DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC5, UL_TFC6 |
RB5: 312 |
RB5: 312 |
2 |
DL_TFC2 |
UL_TFC2 |
DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC5, UL_TFC7 |
RB5: 632 |
RB5: 632 |
3 |
DL_TFC3 |
UL_TFC3 |
DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC3, UL_TFC5, UL_TFC8 |
RB5: 1912 |
RB5: 1272 |
4 |
DL_TFC4 |
UL_TFC4 |
DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC4, UL_TFC5, UL_TFC9 |
RB5: 2552 |
RB5: 2552 |
5 |
DL_TFC5 |
UL_TFC3 |
DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC3, UL_TFC5, UL_TFC8 |
RB5: 2872 |
RB5: 2872 |
NOTE 1: UL_TFC0, UL_TFC1 and UL_TFC5 are part of minimum set of TFCIs. NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs. |
See 18.2.1.1 for test procedure.
18.2.2.29.1.4 Test requirements
See 18.2.1.1 for definition of step 10 and step 15.
1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.
2. At step 15 the UE transmitted transport format shall be
– for sub-test 1: RB5/TF1 (1×336).
– for sub-test 2: RB5/TF2 (2×336) or RB5/TF1 (1×336).
– for sub-test 3: RB5/TF3 (3×336) or RB5/TF1 (1×336).
– for sub-test 4: RB5/TF4 (4×336) or RB5/TF1 (1×336).
– for sub-test 5: RB5/TF3 (3×336) or RB5/TF1 (1×336).
3. At step 15 the UE shall return
– for sub-test 1, 2, 4 and 5: an RLC SDU on RB5 having the same content as the DL RLC SDU sent by the SS.
– for sub-test 3: an RLC SDU on RB5 having the same content as 1 times plus 640 lsb’s of the DL RLC SDU sent by the SS.
18.2.2.29.2 Interactive or background / UL:64 DL:144 kbps / PS RAB + UL:3.4 DL: 3.4 kbps SRBs for DCCH / Payload 128, Physical Configuration 2
18.2.2.29.2.1 Conformance requirement
See 18.2.2.4.1.
18.2.2.29.2.2 Test purpose
Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.10.3.4.1.29 for the uplink payload 128 case with physical configuration 2.
18.2.2.29.2.3 Method of test
Uplink TFS:
TFI |
RB5 (64 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x144 |
0x148 |
TF1, bits |
1×144 |
1×148 |
|
TF2, bits |
3×144 |
N/A |
|
TF3, bits |
7×144 |
N/A |
|
TF4, bits |
10×144 |
N/A |
Uplink TFCS:
TFCI |
(RB5, DCCH) |
UL_TFC0 |
(TF0, TF0) |
UL_TFC1 |
(TF1, TF0) |
UL_TFC2 |
(TF2, TF0) |
UL_TFC3 |
(TF3, TF0) |
UL_TFC4 |
(TF4, TF0) |
UL_TFC5 |
(TF0, TF1) |
UL_TFC6 |
(TF1, TF1) |
UL_TFC7 |
(TF2, TF1) |
UL_TFC8 |
(TF3, TF1) |
UL_TFC9 |
(TF4, TF1) |
Physical channel parameters
DPCH Uplink |
Physical Configuration 2 |
|
Midamble |
512 chips |
|
Codes and time slots |
SF2 x 1 code x 1 time slot + SF4 x 1 code x 1 time slot |
|
Max. Number of data bits/radio frame |
2784 bits |
|
TFCI code word |
16 bits |
|
TPC |
2 bits |
|
Puncturing Limit |
1 |
Downlink TFS:
TFI |
RB5 (144 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x336 |
0x148 |
TF1, bits |
1×336 |
1×148 |
|
TF2, bits |
2×336 |
N/A |
|
TF3, bits |
4×336 |
N/A |
|
TF4, bits |
8×336 |
N/A |
|
TF5, bits |
9×336 |
N/A |
Downlink TFCS:
TFCI |
(RB5, DCCH) |
DL_TFC0 |
(TF0, TF0) |
DL_TFC1 |
(TF1, TF0) |
DL_TFC2 |
(TF2, TF0) |
DL_TFC3 |
(TF3, TF0) |
DL_TFC4 |
(TF4, TF0) |
DL_TFC5 |
(TF5, TF0) |
DL_TFC6 |
(TF0, TF1) |
DL_TFC7 |
(TF1, TF1) |
DL_TFC8 |
(TF2, TF1) |
DL_TFC9 |
(TF3, TF1) |
DL_TFC10 |
(TF4, TF1) |
DL_TFC11 |
(TF5, TF1) |
Sub-tests:
Sub-test |
Downlink TFCS Under test |
Uplink TFCS Under test |
Implicitly tested |
Restricted UL TFCIs (note 1) |
UL RLC SDU size (bits) (note 2) |
Test data size (bits) (note 2) |
1 |
DL_TFC1 |
UL_TFC1 |
DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC5, UL_TFC6 |
RB5: 376 |
RB5: 312 |
2 |
DL_TFC2 |
UL_TFC2 |
DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC5, UL_TFC7 |
RB5: 760 |
RB5: 632 |
3 |
DL_TFC3 |
UL_TFC4 |
DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC4, UL_TFC5, UL_TFC9 |
RB5: 1272 |
RB5: 1272 |
4 |
DL_TFC4 |
UL_TFC4 |
DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC4, UL_TFC5, UL_TFC9 |
RB5: 2552 |
RB5: 2552 |
5 |
DL_TFC5 |
UL_TFC3 |
DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC3, UL_TFC5, UL_TFC8 |
RB5: 3576 |
RB5: 2872 |
NOTE 1: UL_TFC0, UL_TFC1 and UL_TFC5 are part of minimum set of TFCIs. NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs. |
See 18.2.1.1 for test procedure.
18.2.2.29.2.4 Test requirements
See 18.2.1.1 for definition of step 10 and step 15.
1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.
2. At step 15 the UE transmitted transport format shall be
– for sub-test 1: RB5/TF1 (1×144).
– for sub-test 2: RB5/TF2 (3×144).
– for sub-test 3: RB5/TF4 (10×144).
– for sub-test 4: RB5/TF4 (10×144).
– for sub-test 5: RB5/TF3 (7×144).
3. At step 15 the UE shall return
– for sub-test 1: an RLC SDU on RB5 having the same content as 1 times plus 64 lsb’s of the DL RLC SDU sent by the SS.
– for sub-test 2: an RLC SDU on RB5 having the same content as 1 times plus 128 lsb’s of the DL RLC SDU sent by the SS.
– for sub-test 3 and 4: an RLC SDU on RB5 having the same content as the DL RLC SDU sent by the SS.
– for sub-test 5: an RLC SDU on RB5 having the same content as 1 times plus 712 lsb’s of the DL RLC SDU sent by the SS.
18.2.2.30 Interactive or background / UL:144 DL:144 kbps / PS RAB + UL:3.4 DL: 3.4 kbps SRBs for DCCH
18.2.2.30.1 Interactive or background / UL:144 DL:144 kbps / PS RAB + UL:3.4 DL: 3.4 kbps SRBs for DCCH / Payload 320, TTI 20 ms
18.2.2.30.1.1 Conformance requirement
See 18.2.2.4.1.
18.2.2.30.1.2 Test purpose
Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.10.3.4.1.30 for the uplink payload 320, TTI 20 ms case.
18.2.2.30.1.3 Method of test
Uplink TFS:
TFI |
RB5 (144 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x336 |
0x148 |
TF1, bits |
1×336 |
1×148 |
|
TF2, bits |
2×336 |
N/A |
|
TF3, bits |
4×336 |
N/A |
|
TF4, bits |
8×336 |
N/A |
|
TF5, bits |
9×336 |
N/A |
Uplink TFCS:
TFCI |
(RB5, DCCH) |
UL_TFC0 |
(TF0, TF0) |
UL_TFC1 |
(TF1, TF0) |
UL_TFC2 |
(TF2, TF0) |
UL_TFC3 |
(TF3, TF0) |
UL_TFC4 |
(TF4, TF0) |
UL_TFC5 |
(TF5, TF0) |
UL_TFC6 |
(TF0, TF1) |
UL_TFC7 |
(TF1, TF1) |
UL_TFC8 |
(TF2, TF1) |
UL_TFC9 |
(TF3, TF1) |
UL_TFC10 |
(TF4, TF1) |
UL_TFC11 |
(TF5, TF1) |
Downlink TFS:
TFI |
RB5 (144 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x336 |
0x148 |
TF1, bits |
1×336 |
1×148 |
|
TF2, bits |
2×336 |
N/A |
|
TF3, bits |
4×336 |
N/A |
|
TF4, bits |
8×336 |
N/A |
|
TF5, bits |
9×336 |
N/A |
Downlink TFCS:
TFCI |
(RB5, DCCH) |
DL_TFC0 |
(TF0, TF0) |
DL_TFC1 |
(TF1, TF0) |
DL_TFC2 |
(TF2, TF0) |
DL_TFC3 |
(TF3, TF0) |
DL_TFC4 |
(TF4, TF0) |
DL_TFC5 |
(TF5, TF0) |
DL_TFC6 |
(TF0, TF1) |
DL_TFC7 |
(TF1, TF1) |
DL_TFC8 |
(TF2, TF1) |
DL_TFC9 |
(TF3, TF1) |
DL_TFC10 |
(TF4, TF1) |
DL_TFC11 |
(TF5, TF1) |
Sub-tests:
Sub-test |
Downlink TFCS Under test |
Uplink TFCS Under test |
Implicitly tested |
Restricted UL TFCIs (note 1) |
UL RLC SDU size (bits) (note 2) |
Test data size (bits) (note 2) |
1 |
DL_TFC1 |
UL_TFC1 |
DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6 |
UL_TFC0, UL_TFC1, UL_TFC6, UL_TFC7 |
RB5: 312 |
RB5: 312 |
2 |
DL_TFC2 |
UL_TFC2 |
DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6 |
UL_TFC0, UL_TFC1,UL_TFC2, UL_TFC6, UL_TFC8 |
RB5: 632 |
RB5: 632 |
3 |
DL_TFC3 |
UL_TFC3 |
DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6 |
UL_TFC0, UL_TFC1,UL_TFC3, UL_TFC6, UL_TFC9 |
RB5: 1272 |
RB5: 1272 |
4 |
DL_TFC4 |
UL_TFC4 |
DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6 |
UL_TFC0, UL_TFC1,UL_TFC4, UL_TFC6, UL_TFC10 |
RB5: 2552 |
RB5: 2552 |
5 |
DL_TFC5 |
UL_TFC5 |
DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6 |
UL_TFC0, UL_TFC1,UL_TFC5, UL_TFC6, UL_TFC11 |
RB5: 2872 |
RB5: 2872 |
NOTE 1: UL_TFC0, UL_TFC1, and UL_TFC6 are part of minimum set of TFCIs. NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs. |
See 18.2.1.1 for test procedure.
18.2.2.30.1.4 Test requirements
See 18.2.1.1 for definition of step 10 and step 15.
1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.
2. At step 15 the UE transmitted transport format shall be
– for sub-test 1: RB5/TF1 (1×336).
– for sub-test 2: RB5/TF2 (2×336).
– for sub-test 3: RB5/TF3 (4×336).
– for sub-test 4: RB5/TF4 (8×336).
– for sub-test 5: RB5/TF5 (9×336).
3. At step 15 the UE shall return
– for sub-test 1 to 5: an RLC SDU on RB5 having the same content as the DL RLC SDU sent by the SS.
18.2.2.30.2 Interactive or background / UL:144 DL:144 kbps / PS RAB + UL:3.4 DL: 3.4 kbps SRBs for DCCH / Payload 128, TTI 40 ms
18.2.2.30.2.1 Conformance requirement
See 18.2.2.4.1.
18.2.2.30.2.2 Test purpose
Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.10.3.4.1.30 for the uplink payload 128, TTI 40 ms case.
18.2.2.30.2.3 Method of test
Uplink TFS:
TFI |
RB5 (144 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x144 |
0x148 |
TF1, bits |
1×144 |
1×148 |
|
TF2, bits |
10×144 |
N/A |
|
TF3, bits |
20×144 |
N/A |
|
TF4, bits |
30×144 |
N/A |
|
TF5, bits |
45×144 |
N/A |
Uplink TFCS:
TFCI |
(RB5, DCCH) |
UL_TFC0 |
(TF0, TF0) |
UL_TFC1 |
(TF1, TF0) |
UL_TFC2 |
(TF2, TF0) |
UL_TFC3 |
(TF3, TF0) |
UL_TFC4 |
(TF4, TF0) |
UL_TFC5 |
(TF5, TF0) |
UL_TFC6 |
(TF0, TF1) |
UL_TFC7 |
(TF1, TF1) |
UL_TFC8 |
(TF2, TF1) |
UL_TFC9 |
(TF3, TF1) |
UL_TFC10 |
(TF4, TF1) |
UL_TFC11 |
(TF5, TF1) |
Downlink TFS:
TFI |
RB5 (144 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x336 |
0x148 |
TF1, bits |
1×336 |
1×148 |
|
TF2, bits |
2×336 |
N/A |
|
TF3, bits |
4×336 |
N/A |
|
TF4, bits |
8×336 |
N/A |
|
TF5, bits |
9×336 |
N/A |
Downlink TFCS:
TFCI |
(RB5, DCCH) |
DL_TFC0 |
(TF0, TF0) |
DL_TFC1 |
(TF1, TF0) |
DL_TFC2 |
(TF2, TF0) |
DL_TFC3 |
(TF3, TF0) |
DL_TFC4 |
(TF4, TF0) |
DL_TFC5 |
(TF5, TF0) |
DL_TFC6 |
(TF0, TF1) |
DL_TFC7 |
(TF1, TF1) |
DL_TFC8 |
(TF2, TF1) |
DL_TFC9 |
(TF3, TF1) |
DL_TFC10 |
(TF4, TF1) |
DL_TFC11 |
(TF5, TF1) |
Sub-tests:
Sub-test |
Downlink TFCS Under test |
Uplink TFCS Under test |
Implicitly tested |
Restricted UL TFCIs (note 1) |
UL RLC SDU size (bits) (note 2) |
Test data size (bits) (note 2) |
1 |
DL_TFC1 |
UL_TFC1 |
DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6 |
UL_TFC0, UL_TFC1, UL_TFC6, UL_TFC7 |
RB5: 376 |
RB5: 312 |
2 |
DL_TFC2 |
UL_TFC2 |
DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6 |
UL_TFC0, UL_TFC1,UL_TFC2, UL_TFC6, UL_TFC8 |
RB5: 1272 |
RB5: 632 |
3 |
DL_TFC3 |
UL_TFC3 |
DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6 |
UL_TFC0, UL_TFC1,UL_TFC3, UL_TFC6, UL_TFC9 |
RB5: 2552 |
RB5: 1272 |
4 |
DL_TFC4 |
UL_TFC4 |
DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6 |
UL_TFC0, UL_TFC1,UL_TFC4, UL_TFC6, UL_TFC10 |
RB5: 3832 |
RB5: 2552 |
5 |
DL_TFC5 |
UL_TFC5 |
DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6 |
UL_TFC0, UL_TFC1,UL_TFC5, UL_TFC6, UL_TFC11 |
RB5: 5752 |
RB5: 2872 |
NOTE 1: UL_TFC0, UL_TFC1, and UL_TFC6 are part of minimum set of TFCIs. NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs. |
See 18.2.1.1 for test procedure.
18.2.2.30.2.4 Test requirements
See 18.2.1.1 for definition of step 10 and step 15.
1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.
2. At step 15 the UE transmitted transport format shall be
– for sub-test 1: RB5/TF1 (1×144).
– for sub-test 2: RB5/TF2 (10×144).
– for sub-test 3: RB5/TF3 (20×144).
– for sub-test 4: RB5/TF4 (30×144).
– for sub-test 5: RB5/TF5 (45×144).
3. At step 15 the UE shall return
– for sub-test 1: an RLC SDU on RB5 having the same content as 1 times plus 64 lsb’s of the DL RLC SDU sent by the SS.
– for sub-test 2: an RLC SDU on RB5 having the same content as 1 times plus 640 lsb’s of the DL RLC SDU sent by the SS.
– for sub-test 3: an RLC SDU on RB5 having the same content as 1 times plus 1280 lsb’s of the DL RLC SDU sent by the SS.
– for sub-test 4: an RLC SDU on RB5 having the same content as 1 times plus 1280 lsb’s of the DL RLC SDU sent by the SS.
– for sub-test 5: an RLC SDU on RB5 having the same content as 1 times plus 2880 lsb’s of the DL RLC SDU sent by the SS.
18.2.2.31 Interactive or background / UL:64 DL:256 kbps / PS RAB + UL:3.4 DL: 3.4 kbps SRBs for DCCH
18.2.2.31.1 Interactive or background / UL:64 DL:256 kbps / PS RAB + UL:3.4 DL: 3.4 kbps SRBs for DCCH/ Payload 320, 10 ms TTI Down Link, Physical Configuration 1
18.2.2.31.1.1 Conformance requirement
See 18.2.2.4.1.
18.2.2.31.1.2 Test purpose
Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.10.3.4.1.31 for the uplink payload 320, the downlink 10 ms TTI, and physical configuration 1 case.
18.2.2.31.1.3 Method of test
Uplink TFS:
TFI |
RB5 (64 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x336 |
0x148 |
TF1, bits |
1×336 |
1×148 |
|
TF2, bits |
2×336 |
N/A |
|
TF3, bits |
3×336 |
N/A |
|
TF4, bits |
4×336 |
N/A |
Uplink TFCS:
TFCI |
(RB5, DCCH) |
UL_TFC0 |
(TF0, TF0) |
UL_TFC1 |
(TF1, TF0) |
UL_TFC2 |
(TF2, TF0) |
UL_TFC3 |
(TF3, TF0) |
UL_TFC4 |
(TF4, TF0) |
UL_TFC5 |
(TF0, TF1) |
UL_TFC6 |
(TF1, TF1) |
UL_TFC7 |
(TF2, TF1) |
UL_TFC8 |
(TF3, TF1) |
UL_TFC9 |
(TF4, TF1) |
Physical channel parameters
DPCH Uplink |
Physical Configuration 1 |
|
Midamble |
512 chips |
|
Codes and time slots |
SF16 x 1 code x 1 time slot + SF4 x 1 code x 1 time slot |
|
Max. Number of data bits/radio frame |
1148 bits |
|
TFCI code word |
16 bits |
|
TPC |
2 bits |
|
Puncturing Limit |
0.48 (alt. 0.44) |
Downlink TFS:
TFI |
RB5 (256 kbps, 10ms) |
DCCH |
|
TFS |
TF0, bits |
0x336 |
0x148 |
TF1, bits |
1×336 |
1×148 |
|
TF2, bits |
2×336 |
N/A |
|
TF3, bits |
4×336 |
N/A |
|
TF4, bits |
8×336 |
N/A |
Downlink TFCS:
TFCI |
(RB5, DCCH) |
DL_TFC0 |
(TF0, TF0) |
DL_TFC1 |
(TF1, TF0) |
DL_TFC2 |
(TF2, TF0) |
DL_TFC3 |
(TF3, TF0) |
DL_TFC4 |
(TF4, TF0) |
DL_TFC5 |
(TF0, TF1) |
DL_TFC6 |
(TF1, TF1) |
DL_TFC7 |
(TF2, TF1) |
DL_TFC8 |
(TF3, TF1) |
DL_TFC9 |
(TF4, TF1) |
Sub-tests:
Sub-test |
Downlink TFCS Under test |
Uplink TFCS Under test |
Implicitly tested |
Restricted UL TFCIs (note 1) |
UL RLC SDU size (bits) (note 2) |
Test data size (bits) (note 2) |
1 |
DL_TFC1 |
UL_TFC1 |
DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC5, UL_TFC6 |
RB5: 312 |
RB5: 312 |
2 |
DL_TFC2 |
UL_TFC2 |
DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC5, UL_TFC7 |
RB5: 632 |
RB5: 632 |
3 |
DL_TFC3 |
UL_TFC3 |
DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC3, UL_TFC5, UL_TFC8 |
RB5: 1912 |
RB5: 1272 |
4 |
DL_TFC4 |
UL_TFC4 |
DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC4, UL_TFC5, UL_TFC9 |
RB5: 2552 |
RB5: 2552 |
NOTE 1: UL_TFC0, UL_TFC1 and UL_TFC5 are part of minimum set of TFCIs. NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs. |
See 18.2.1.1 for test procedure.
18.2.2.31.1.4 Test requirements
See 18.2.1.1 for definition of step 10 and step 15.
1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.
2. At step 15 the UE transmitted transport format shall be
– for sub-test 1: RB5/TF1 (1×336).
– for sub-test 2: RB5/TF2 (2×336) or RB5/TF1 (1×336).
– for sub-test 3: RB5/TF3 (3×336) or RB5/TF1 (1×336).
– for sub-test 4: RB5/TF4 (4×336) or RB5/TF1 (1×336).
3. At step 15 the UE shall return
– for sub-test 1, 2 and 4: an RLC SDU on RB5 having the same content as the DL RLC SDU sent by the SS.
– for sub-test 3: an RLC SDU on RB5 having the same content as 1 times plus 640 lsb’s of the DL RLC SDU sent by the SS.
18.2.2.31.2 Interactive or background / UL:64 DL:256 kbps / PS RAB / Payload 128, 20 ms TTI Down Link, Physical Configuration 2
18.2.2.31.2.1 Conformance requirement
See 18.2.2.4.1.
18.2.2.31.2.2 Test purpose
Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.10.3.4.1.31 for the uplink payload 128, the downlink 20 ms TTI, and physical configuration 2 case.
18.2.2.31.2.3 Method of test
Uplink TFS:
TFI |
RB5 (64 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x144 |
0x148 |
TF1, bits |
1×144 |
1×148 |
|
TF2, bits |
3×144 |
N/A |
|
TF3, bits |
7×144 |
N/A |
|
TF4, bits |
10×144 |
N/A |
Uplink TFCS:
TFCI |
(RB5, DCCH) |
UL_TFC0 |
(TF0, TF0) |
UL_TFC1 |
(TF1, TF0) |
UL_TFC2 |
(TF2, TF0) |
UL_TFC3 |
(TF3, TF0) |
UL_TFC4 |
(TF4, TF0) |
UL_TFC5 |
(TF0, TF1) |
UL_TFC6 |
(TF1, TF1) |
UL_TFC7 |
(TF2, TF1) |
UL_TFC8 |
(TF3, TF1) |
UL_TFC9 |
(TF4, TF1) |
Physical channel parameters
DPCH Uplink |
Physical Configuration 2 |
|
Midamble |
512 chips |
|
Codes and time slots |
SF2 x 1 code x 1 time slot + SF4 x 1 code x 1 time slot |
|
Max. Number of data bits/radio frame |
2784 bits |
|
TFCI code word |
16 bits |
|
TPC |
2 bits |
|
Puncturing Limit |
1 |
Downlink TFS:
TFI |
RB5 (256 kbps, 20ms) |
DCCH |
|
TFS |
TF0, bits |
0x336 |
0x148 |
TF1, bits |
1×336 |
1×148 |
|
TF2, bits |
2×336 |
N/A |
|
TF3, bits |
4×336 |
N/A |
|
TF4, bits |
8×336 |
N/A |
|
TF5, bits |
12×336 |
N/A |
|
TF6, bits |
16×336 |
N/A |
Downlink TFCS:
TFCI |
(RB5, DCCH) |
DL_TFC0 |
(TF0, TF0) |
DL_TFC1 |
(TF1, TF0) |
DL_TFC2 |
(TF2, TF0) |
DL_TFC3 |
(TF3, TF0) |
DL_TFC4 |
(TF4, TF0) |
DL_TFC5 |
(TF5, TF0) |
DL_TFC6 |
(TF6, TF0) |
DL_TFC7 |
(TF0, TF1) |
DL_TFC8 |
(TF1, TF1) |
DL_TFC9 |
(TF2, TF1) |
DL_TFC10 |
(TF3, TF1) |
DL_TFC11 |
(TF4, TF1) |
DL_TFC12 |
(TF5, TF1) |
DL_TFC13 |
(TF6, TF1) |
Sub-tests:
Sub-test |
Downlink TFCS Under test |
Uplink TFCS Under test |
Implicitly tested |
Restricted UL TFCIs (note 1) |
UL RLC SDU size (bits) (note 2) |
Test data size (bits) (note 2) |
1 |
DL_TFC1 |
UL_TFC1 |
DL_TFC0, DL_TFC7, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC5, UL_TFC6 |
RB5: 376 |
RB5: 312 |
2 |
DL_TFC2 |
UL_TFC2 |
DL_TFC0, DL_TFC7, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC5, UL_TFC7 |
RB5: 760 |
RB5: 632 |
3 |
DL_TFC3 |
UL_TFC3 |
DL_TFC0, DL_TFC7, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC3, UL_TFC5, UL_TFC8 |
RB5: 1784 |
RB5: 1272 |
4 |
DL_TFC4 |
UL_TFC4 |
DL_TFC0, DL_TFC7, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC4, UL_TFC5, UL_TFC9 |
RB5: 2552 |
RB5: 2552 |
5 |
DL_TFC5 |
UL_TFC4 |
DL_TFC0, DL_TFC7, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC4, UL_TFC5, UL_TFC9 |
RB5: 3832 |
RB5: 3832 |
6 |
DL_TFC6 |
UL_TFC4 |
DL_TFC0, DL_TFC7, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC4, UL_TFC5, UL_TFC9 |
RB5: 5112 |
RB5: 5112 |
NOTE 1: UL_TFC0, UL_TFC1, and UL_TFC5 are part of minimum set of TFCIs. NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs. |
See 18.2.1.1 for test procedure.
18.2.2.31.2.4 Test requirements
See 18.2.1.1 for definition of step 10 and step 15.
1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.
2. At step 15 the UE transmitted transport format shall be
– for sub-test 1: RB5/TF1 (1×144).
– for sub-test 2: RB5/TF2 (3×144).
– for sub-test 3: RB5/TF3 (7×144).
– for sub-test 4 to 6: RB5/TF4 (10×144).
3. At step 15 the UE shall return
– for sub-test 1: an RLC SDU on RB5 having the same content as 1 times plus 64 lsb’s of the DL RLC SDU sent by the SS.
– for sub-test 2: an RLC SDU on RB5 having the same content as 1 times plus 128 lsb’s of the DL RLC SDU sent by the SS.
– for sub-test 3: an RLC SDU on RB5 having the same content as 1 times plus 512 lsb’s of the DL RLC SDU sent by the SS.
– for sub-test 4 to 6: an RLC SDU on RB5 having the same content as the DL RLC SDU sent by the SS.
18.2.2.32 Interactive or background / UL:64 DL:384 kbps / PS RAB + UL:3.4 DL: 3.4 kbps SRBs for DCCH
18.2.2.32.1 Interactive or background / UL:64 DL:384 kbps / PS RAB / Payload 320, 10 ms TTI Down Link, Physical Configuration 1
18.2.2.32.1.1 Conformance requirement
See 18.2.2.4.1.
18.2.2.32.1.2 Test purpose
Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.10.3.4.1.32 for the uplink payload 320, the downlink 10 ms TTI, and physical configuration 1 case.
18.2.2.32.1.3 Method of test
Uplink TFS:
TFI |
RB5 (64 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x336 |
0x148 |
TF1, bits |
1×336 |
1×148 |
|
TF2, bits |
2×336 |
N/A |
|
TF3, bits |
3×336 |
N/A |
|
TF4, bits |
4×336 |
N/A |
Uplink TFCS:
TFCI |
(RB5, DCCH) |
UL_TFC0 |
(TF0, TF0) |
UL_TFC1 |
(TF1, TF0) |
UL_TFC2 |
(TF2, TF0) |
UL_TFC3 |
(TF3, TF0) |
UL_TFC4 |
(TF4, TF0) |
UL_TFC5 |
(TF0, TF1) |
UL_TFC6 |
(TF1, TF1) |
UL_TFC7 |
(TF2, TF1) |
UL_TFC8 |
(TF3, TF1) |
UL_TFC9 |
(TF4, TF1) |
Physical channel parameters
DPCH Uplink |
Physical Configuration 1 |
|
Midamble |
512 chips |
|
Codes and time slots |
SF16 x 1 code x 1 time slot + SF4 x 1 code x 1 time slot |
|
Max. Number of data bits/radio frame |
1148 bits |
|
TFCI code word |
16 bits |
|
TPC |
2 bits |
|
Puncturing Limit |
0.48 (alt. 0.44) |
Downlink TFS:
TFI |
RB5 (384 kbps, 10ms) |
DCCH |
|
TFS |
TF0, bits |
0x336 |
0x148 |
TF1, bits |
1×336 |
1×148 |
|
TF2, bits |
2×336 |
N/A |
|
TF3, bits |
4×336 |
N/A |
|
TF4, bits |
8×336 |
N/A |
|
TF5, bits |
12×336 |
N/A |
Downlink TFCS:
TFCI |
(RB5, DCCH) |
DL_TFC0 |
(TF0, TF0) |
DL_TFC1 |
(TF1, TF0) |
DL_TFC2 |
(TF2, TF0) |
DL_TFC3 |
(TF3, TF0) |
DL_TFC4 |
(TF4, TF0) |
DL_TFC5 |
(TF5, TF0) |
DL_TFC6 |
(TF0, TF1) |
DL_TFC7 |
(TF1, TF1) |
DL_TFC8 |
(TF2, TF1) |
DL_TFC9 |
(TF3, TF1) |
DL_TFC10 |
(TF4, TF1) |
DL_TFC11 |
(TF5, TF1) |
Physical channel parameters
DPCH Downlink |
Physical Configuration 1 |
|
Midamble |
256 chips |
|
Codes and time slots |
SF16 x 8 codes x 3 time slots |
|
Max. Number of data bits/radio frame |
6608 bits |
|
TFCI code word |
16 bits |
|
Puncturing Limit |
0.48 |
Sub-tests:
Sub-test |
Downlink TFCS Under test |
Uplink TFCS Under test |
Implicitly tested |
Restricted UL TFCIs (note 1) |
UL RLC SDU size (bits) (note 1) |
Test data size (bits) (note 1) |
1 |
DL_TFC1 |
UL_TFC1 |
DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC5, UL_TFC6 |
RB5: 312 |
RB5: 312 |
2 |
DL_TFC2 |
UL_TFC2 |
DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC5, UL_TFC7 |
RB5: 632 |
RB5: 632 |
3 |
DL_TFC3 |
UL_TFC3 |
DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC3, UL_TFC5, UL_TFC8 |
RB5: 1912 |
RB5: 1272 |
4 |
DL_TFC4 |
UL_TFC4 |
DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC4, UL_TFC5, UL_TFC9 |
RB5: 2552 |
RB5: 2552 |
5 |
DL_TFC5 |
UL_TFC4 |
DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC4, UL_TFC5, UL_TFC9 |
RB5: 3832 |
RB5: 3832 |
NOTE 1: UL_TFC0, UL_TFC1 and UL_TFC5 are part of minimum set of TFCIs. NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs. |
See 18.2.1.1 for test procedure.
18.2.2.32.1.4 Test requirements
See 18.2.1.1 for definition of step 10 and step 15.
1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.
2. At step 15 the UE transmitted transport format shall be
– for sub-test 1: RB5/TF1 (1×336).
– for sub-test 2: RB5/TF2 (2×336) or RB5/TF1 (1×336).
– for sub-test 3: RB5/TF3 (3×336) or RB5/TF1 (1×336).
– for sub-test 4 and 5: RB5/TF4 (4×336) or RB5/TF1 (1×336).
3. At step 15 the UE shall return
– for sub-test 1, 2, 4 and 5: an RLC SDU on RB5 having the same content as the DL RLC SDU sent by the SS.
– for sub-test 3: an RLC SDU on RB5 having the same content as 1 times plus 640 lsb’s of the DL RLC SDU sent by the SS.
18.2.2.32.2 Interactive or background / UL:64 DL:384 kbps / PS RAB / Payload 128, 20 ms TTI Down Link, Physical Configuration 2
18.2.2.32.2.1 Conformance requirement
See 18.2.2.4.1.
18.2.2.32.2.2 Test purpose
Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.10.3.4.1.32 for the uplink payload 128, the downlink 20 ms TTI, and physical configuration 2 case.
18.2.2.32.2.3 Method of test
Uplink TFS:
TFI |
RB5 (64 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x144 |
0x148 |
TF1, bits |
1×144 |
1×148 |
|
TF2, bits |
3×144 |
N/A |
|
TF3, bits |
7×144 |
N/A |
|
TF4, bits |
10×144 |
N/A |
Uplink TFCS:
TFCI |
(RB5, DCCH) |
UL_TFC0 |
(TF0, TF0) |
UL_TFC1 |
(TF1, TF0) |
UL_TFC2 |
(TF2, TF0) |
UL_TFC3 |
(TF3, TF0) |
UL_TFC4 |
(TF4, TF0) |
UL_TFC5 |
(TF0, TF1) |
UL_TFC6 |
(TF1, TF1) |
UL_TFC7 |
(TF2, TF1) |
UL_TFC8 |
(TF3, TF1) |
UL_TFC9 |
(TF4, TF1) |
Physical channel parameters
DPCH Uplink |
Physical Configuration 2 |
|
Midamble |
512 chips |
|
Codes and time slots |
SF2 x 1 code x 1 time slot + SF4 x 1 code x 1 time slot |
|
Max. Number of data bits/radio frame |
2784 bits |
|
TFCI code word |
16 bits |
|
TPC |
2 bits |
|
Puncturing Limit |
1 |
Downlink TFS:
TFI |
RB5 (384 kbps, 20ms) |
DCCH |
|
TFS |
TF0, bits |
0x336 |
0x148 |
TF1, bits |
1×336 |
1×148 |
|
TF2, bits |
2×336 |
N/A |
|
TF3, bits |
4×336 |
N/A |
|
TF4, bits |
8×336 |
N/A |
|
TF5, bits |
12×336 |
N/A |
|
TF6, bits |
16×336 |
N/A |
|
TF7, bits |
20×336 |
N/A |
|
TF8, bits |
24×336 |
N/A |
Downlink TFCS:
TFCI |
(RB5, DCCH) |
DL_TFC0 |
(TF0, TF0) |
DL_TFC1 |
(TF1, TF0) |
DL_TFC2 |
(TF2, TF0) |
DL_TFC3 |
(TF3, TF0) |
DL_TFC4 |
(TF4, TF0) |
DL_TFC5 |
(TF5, TF0) |
DL_TFC6 |
(TF6, TF0) |
DL_TFC7 |
(TF7, TF0) |
DL_TFC8 |
(TF8, TF0) |
DL_TFC9 |
(TF0, TF1) |
DL_TFC10 |
(TF1, TF1) |
DL_TFC11 |
(TF2, TF1) |
DL_TFC12 |
(TF3, TF1) |
DL_TFC13 |
(TF4, TF1) |
DL_TFC14 |
(TF5, TF1) |
DL_TFC15 |
(TF6, TF1) |
DL_TFC16 |
(TF7, TF1) |
DL_TFC17 |
(TF8, TF1) |
Physical channel parameters
DPCH Downlink |
Physical Configuration 2 |
|
Midamble |
256 chips |
|
Codes and time slots |
SF16 x 6 codes x 4 time slots + SF16 x 4 codes x 1 time slot (alt. SF1 x 1 code x 3 time slots) |
|
Max. Number of data bits/radio frame |
7712 bits (alt. 13232 bits) |
|
TFCI code word |
16 bits |
|
Puncturing Limit |
0.60 (alt. 1) |
Sub-tests:
Sub-test |
Downlink TFCS Under test |
Uplink TFCS Under test |
Implicitly tested |
Restricted UL TFCIs (note 1) |
UL RLC SDU size (bits) (note 2) |
Test data size (bits) (note 2) |
1 |
DL_TFC1 |
UL_TFC1 |
DL_TFC0, DL_TFC9, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC5, UL_TFC6 |
RB5: 376 |
RB5: 312 |
2 |
DL_TFC2 |
UL_TFC2 |
DL_TFC0, DL_TFC9, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1,UL_TFC2, UL_TFC5, UL_TFC7 |
RB5: 760 |
RB5: 632 |
3 |
DL_TFC3 |
UL_TFC3 |
DL_TFC0, DL_TFC9, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1,UL_TFC3, UL_TFC5, UL_TFC8 |
RB5: 1784 |
RB5: 1272 |
4 |
DL_TFC4 |
UL_TFC4 |
DL_TFC0, DL_TFC9, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1,UL_TFC4, UL_TFC5, UL_TFC9 |
RB5: 2552 |
RB5: 2552 |
5 |
DL_TFC5 |
UL_TFC4 |
DL_TFC0, DL_TFC9, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1,UL_TFC4, UL_TFC5, UL_TFC9 |
RB5: 3832 |
RB5: 3832 |
6 |
DL_TFC6 |
UL_TFC4 |
DL_TFC0, DL_TFC9, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1,UL_TFC4, UL_TFC5, UL_TFC9 |
RB5: 5112 |
RB5: 5112 |
7 |
DL_TFC7 |
UL_TFC4 |
DL_TFC0, DL_TFC9, , UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1,UL_TFC4, UL_TFC5, UL_TFC9 |
RB5: 6392 |
RB5: 6392 |
8 |
DL_TFC8 |
UL_TFC4 |
DL_TFC0, DL_TFC9, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1,UL_TFC4, UL_TFC5, UL_TFC9 |
RB5: 7672 |
RB5: 7672 |
NOTE 1: UL_TFC0, UL_TFC1, and UL_TFC5 are part of minimum set of TFCIs. NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs. |
See 18.2.1.1 for test procedure.
18.2.2.32.2.4 Test requirements
See 18.2.1.1 for definition of step 10 and step 15.
1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.
2. At step 15 the UE transmitted transport format shall be
– for sub-test 1: RB5/TF1 (1×144).
– for sub-test 2: RB5/TF2 (3×144).
– for sub-test 3: RB5/TF3 (7×144).
– for sub-test 4 to 8: RB5/TF4 (10×144).
3. At step 15 the UE shall return
– for sub-test 1: an RLC SDU on RB5 having the same content as 1 times plus 64 lsb’s of the DL RLC SDU sent by the SS.
– for sub-test 2: an RLC SDU on RB5 having the same content as 1 times plus 128 lsb’s of the DL RLC SDU sent by the SS.
– for sub-test 3: an RLC SDU on RB5 having the same content as 1 times plus 512 lsb’s of the DL RLC SDU sent by the SS.
– for sub-test 4 to 8: an RLC SDU on RB5 having the same content as the DL RLC SDU sent by the SS.
18.2.2.33 Interactive or background / UL:128 DL:384 kbps / PS RAB + UL:3.4 DL: 3.4 kbps SRBs for DCCH
18.2.2.33.1 Interactive or background / UL:128 DL:384 kbps / PS RAB / Payload 320, 10 ms TTI Down Link, Physical Configuration 1
18.2.2.33.1.1 Conformance requirement
See 18.2.2.4.1.
18.2.2.33.1.2 Test purpose
Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.10.3.4.1.33 for the uplink payload 320, the downlink 10 ms TTI, and physical configuration 1 case.
18.2.2.33.1.3 Method of test
Uplink TFS:
TFI |
RB5 (128 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x336 |
0x148 |
TF1, bits |
1×336 |
1×148 |
|
TF2, bits |
2×336 |
N/A |
|
TF3, bits |
4×336 |
N/A |
|
TF4, bits |
8×336 |
N/A |
Uplink TFCS:
TFCI |
(RB5, DCCH) |
UL_TFC0 |
(TF0, TF0) |
UL_TFC1 |
(TF1, TF0) |
UL_TFC2 |
(TF2, TF0) |
UL_TFC3 |
(TF3, TF0) |
UL_TFC4 |
(TF4, TF0) |
UL_TFC5 |
(TF0, TF1) |
UL_TFC6 |
(TF1, TF1) |
UL_TFC7 |
(TF2, TF1) |
UL_TFC8 |
(TF3, TF1) |
UL_TFC9 |
(TF4, TF1) |
Physical channel parameters
DPCH Uplink |
Physical Configuration 1 |
|
Midamble |
256 chips |
|
Codes and time slots |
SF2 x 1 code x 1 timeslot |
|
Max. Number of data bits/radio frame |
2064 bits |
|
TFCI code word |
16 bits |
|
TPC |
2 bits |
|
Puncturing Limit |
0.44 (alt. 0.40) |
Downlink TFS:
TFI |
RB5 (384 kbps, 10ms) |
DCCH |
|
TFS |
TF0, bits |
0x336 |
0x148 |
TF1, bits |
1×336 |
1×148 |
|
TF2, bits |
2×336 |
N/A |
|
TF3, bits |
4×336 |
N/A |
|
TF4, bits |
8×336 |
N/A |
|
TF5, bits |
12×336 |
N/A |
Downlink TFCS:
TFCI |
(RB5, DCCH) |
DL_TFC0 |
(TF0, TF0) |
DL_TFC1 |
(TF1, TF0) |
DL_TFC2 |
(TF2, TF0) |
DL_TFC3 |
(TF3, TF0) |
DL_TFC4 |
(TF4, TF0) |
DL_TFC5 |
(TF5, TF0) |
DL_TFC6 |
(TF0, TF1) |
DL_TFC7 |
(TF1, TF1) |
DL_TFC8 |
(TF2, TF1) |
DL_TFC9 |
(TF3, TF1) |
DL_TFC10 |
(TF4, TF1) |
DL_TFC11 |
(TF5, TF1) |
Physical channel parameters
DPCH Downlink |
Physical Configuration 1 |
|
Midamble |
256 chips |
|
Codes and time slots |
SF16 x 8 codes x 3 time slots |
|
Max. Number of data bits/radio frame |
6608 bits |
|
TFCI code word |
16 bits |
|
Puncturing Limit |
0.48 |
Sub-tests:
Sub-test |
Downlink TFCS Under test |
Uplink TFCS Under test |
Implicitly tested |
Restricted UL TFCIs (note 1) |
UL RLC SDU size (bits) (note 2) |
Test data size (bits) (note 2) |
1 |
DL_TFC1 |
UL_TFC1 |
DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC5, UL_TFC6 |
RB5: 312 |
RB5: 312 |
2 |
DL_TFC2 |
UL_TFC2 |
DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1,UL_TFC2, UL_TFC5, UL_TFC7 |
RB5: 632 |
RB5: 632 |
3 |
DL_TFC3 |
UL_TFC3 |
DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1,UL_TFC3, UL_TFC5, UL_TFC8 |
RB5: 1272 |
RB5: 1272 |
4 |
DL_TFC4 |
UL_TFC4 |
DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1,UL_TFC4, UL_TFC5, UL_TFC9 |
RB5: 2552 |
RB5: 2552 |
5 |
DL_TFC5 |
UL_TFC3 |
DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1,UL_TFC3, UL_TFC5, UL_TFC8 |
RB5: 3832 |
RB5: 3832 |
NOTE 1: UL_TFC0, UL_TFC1, and UL_TFC5 are part of minimum set of TFCIs. NOTE2 : See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs. |
See 18.2.1.1 for test procedure.
18.2.2.33.1.4 Test requirements
See 18.2.1.1 for definition of step 10 and step 15.
1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.
2. At step 15 the UE transmitted transport format shall be
– for sub-test 1: RB5/TF1 (1×336).
– for sub-test 2: RB5/TF2 (2×336).
– for sub-test 3: RB5/TF3 (4×336).
– for sub-test 4 and 5: RB5/TF4 (8×336).
3. At step 15 the UE shall return
– for sub-test 1 to 5: an RLC SDU on RB5 having the same content as the DL RLC SDU sent by the SS.
18.2.2.33.2 Interactive or background / UL:128 DL:384 kbps / PS RAB / Payload 128, 20 ms TTI Down Link, Physical Configuration 2
18.2.2.33.2.1 Conformance requirement
See 18.2.2.4.1.
18.2.2.33.2.2 Test purpose
Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.10.3.4.1.33 for the uplink payload 128, the downlink 20 ms TTI, and physical configuration 2 case.
18.2.2.33.2.3 Method of test
Uplink TFS:
TFI |
RB5 (128 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x144 |
0x148 |
TF1, bits |
1×144 |
1×148 |
|
TF2, bits |
7×144 |
N/A |
|
TF3, bits |
14×144 |
N/A |
|
TF4, bits |
20×144 |
N/A |
Uplink TFCS:
TFCI |
(RB5, DCCH) |
UL_TFC0 |
(TF0, TF0) |
UL_TFC1 |
(TF1, TF0) |
UL_TFC2 |
(TF2, TF0) |
UL_TFC3 |
(TF3, TF0) |
UL_TFC4 |
(TF4, TF0) |
UL_TFC5 |
(TF0, TF1) |
UL_TFC6 |
(TF1, TF1) |
UL_TFC7 |
(TF2, TF1) |
UL_TFC8 |
(TF3, TF1) |
UL_TFC9 |
(TF4, TF1) |
Physical channel parameters
DPCH Uplink |
Physical Configuration 2 |
|
Midamble |
256 chips |
|
Codes and time slots |
SF2 x 1 code x 2 timeslots + SF4 x 1 code x 1 time slot |
|
Max. Number of data bits/radio frame |
5376 bits |
|
TFCI code word |
16 bits |
|
TPC |
2 bits |
|
Puncturing Limit |
1 |
Downlink TFS:
TFI |
RB5 (384 kbps, 20ms) |
DCCH |
|
TFS |
TF0, bits |
0x336 |
0x148 |
TF1, bits |
1×336 |
1×148 |
|
TF2, bits |
2×336 |
N/A |
|
TF3, bits |
4×336 |
N/A |
|
TF4, bits |
8×336 |
N/A |
|
TF5, bits |
12×336 |
N/A |
|
TF6, bits |
16×336 |
N/A |
|
TF7, bits |
20×336 |
N/A |
|
TF8, bits |
24×336 |
N/A |
Downlink TFCS:
TFCI |
(RB5, DCCH) |
DL_TFC0 |
(TF0, TF0) |
DL_TFC1 |
(TF1, TF0) |
DL_TFC2 |
(TF2, TF0) |
DL_TFC3 |
(TF3, TF0) |
DL_TFC4 |
(TF4, TF0) |
DL_TFC5 |
(TF5, TF0) |
DL_TFC6 |
(TF6, TF0) |
DL_TFC7 |
(TF7, TF0) |
DL_TFC8 |
(TF8, TF0) |
DL_TFC9 |
(TF0, TF1) |
DL_TFC10 |
(TF1, TF1) |
DL_TFC11 |
(TF2, TF1) |
DL_TFC12 |
(TF3, TF1) |
DL_TFC13 |
(TF4, TF1) |
DL_TFC14 |
(TF5, TF1) |
DL_TFC15 |
(TF6, TF1) |
DL_TFC16 |
(TF7, TF1) |
DL_TFC17 |
(TF8, TF1) |
Physical channel parameters
DPCH Downlink |
Physical Configuration 2 |
|
Midamble |
256 chips |
|
Codes and time slots |
SF16 x 6 codes x 4 time slots + SF16 x 4 codes x 1 time slot (alt. SF1 x 1 code x 3 time slots) |
|
Max. Number of data bits/radio frame |
7712 bits (alt. 13232 bits) |
|
TFCI code word |
16 bits |
|
Puncturing Limit |
0.60 (alt. 1) |
Sub-tests:
Sub-test |
Downlink TFCS Under test |
Uplink TFCS Under test |
Implicitly tested |
Restricted UL TFCIs (note 1) |
UL RLC SDU size (bits) (note 2) |
Test data size (bits) (note 2) |
1 |
DL_TFC1 |
UL_TFC1 |
DL_TFC0, DL_TFC9, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC5, UL_TFC6 |
RB5: 376 |
RB5: 312 |
2 |
DL_TFC2 |
UL_TFC2 |
DL_TFC0, DL_TFC9, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC5, UL_TFC7 |
RB5: 888 |
RB5: 632 |
3 |
DL_TFC3 |
UL_TFC3 |
DL_TFC0, DL_TFC9, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC3, UL_TFC5, UL_TFC8 |
RB5: 1784 |
RB5: 1272 |
4 |
DL_TFC4 |
UL_TFC4 |
DL_TFC0, DL_TFC9, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC4, UL_TFC5, UL_TFC9 |
RB5: 2552 |
RB5: 2552 |
5 |
DL_TFC5 |
UL_TFC4 |
DL_TFC0, DL_TFC9, UL_TFC0, UL_TFC5, |
UL_TFC0, UL_TFC1, UL_TFC4, UL_TFC5, UL_TFC9 |
RB5: 5112 |
RB5: 3832 |
6 |
DL_TFC6 |
UL_TFC4 |
DL_TFC0, DL_TFC9, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC4, UL_TFC5, UL_TFC9 |
RB5: 5112 |
RB5: 5112 |
7 |
DL_TFC7 |
UL_TFC4 |
DL_TFC0, DL_TFC9, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC4, UL_TFC5, UL_TFC9 |
RB5: 7672 |
RB5: 6392 |
8 |
DL_TFC8 |
UL_TFC4 |
DL_TFC0, DL_TFC9, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC4 UL_TFC5, UL_TFC9 |
RB5: 7672 |
RB5: 7672 |
NOTE 1: UL_TFC0, UL_TFC1, and UL_TFC5 are part of minimum set of TFCIs. NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs. |
See 18.2.1.1 for test procedure.
18.2.2.33.2.4 Test requirements
See 18.2.1.1 for definition of step 10 and step 15.
1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.
2. At step 15 the UE transmitted transport format shall be
– for sub-test 1: RB5/TF1 (1×144).
– for sub-test 2: RB5/TF2 (7×144).
– for sub-test 3: RB5/TF3 (14×144).
– for sub-test 4 to 8: RB5/TF4 (20×144).
3. At step 15 the UE shall return
– for sub-test 1: an RLC SDU on RB5 having the same content as 1 times plus 64 lsb’s of the DL RLC SDU sent by the SS.
– for sub-test 2: an RLC SDU on RB5 having the same content as 1 times plus 256 lsb’s of the DL RLC SDU sent by the SS.
– for sub-test 3: an RLC SDU on RB5 having the same content as 1 times plus 512 lsb’s of the DL RLC SDU sent by the SS.
– for sub-test 4, 6, and 8: an RLC SDU on RB5 having the same content as the DL RLC SDU sent by the SS.
– for sub-test 5: an RLC SDU on RB5 having the same content as 1 times plus 1280 lsb’s of the DL RLC SDU sent by the SS.
– for sub-test 7: an RLC SDU on RB5 having the same content as 1 times plus 1280 lsb’s of the DL RLC SDU sent by the SS.
18.2.2.34 Interactive or background / UL:384 DL:384 kbps / PS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH
18.2.2.34.1 Interactive or background / UL:384 DL:384 kbps / PS RAB / 10 ms TTI, Physical Configuration 1
18.2.2.34.1.1 Conformance requirement
See 18.2.2.4.1.
18.2.2.34.1.2 Test purpose
Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.10.3.4.1.34 for the 10 ms TTI, physical configuration 1 case.
18.2.2.34.1.3 Method of test
Uplink TFS:
TFI |
RB5 (384 kbps, 10ms) |
DCCH |
|
TFS |
TF0, bits |
0x336 |
0x148 |
TF1, bits |
1×336 |
1×148 |
|
TF2, bits |
2×336 |
N/A |
|
TF3, bits |
4×336 |
N/A |
|
TF4, bits |
8×336 |
N/A |
|
TF5, bits |
12×336 |
N/A |
Uplink TFCS:
TFCI |
(RB5, DCCH) |
UL_TFC0 |
(TF0, TF0) |
UL_TFC1 |
(TF1, TF0) |
UL_TFC2 |
(TF2, TF0) |
UL_TFC3 |
(TF3, TF0) |
UL_TFC4 |
(TF4, TF0) |
UL_TFC5 |
(TF5, TF0) |
UL_TFC6 |
(TF0, TF1) |
UL_TFC7 |
(TF1, TF1) |
UL_TFC8 |
(TF2, TF1) |
UL_TFC9 |
(TF3, TF1) |
UL_TFC10 |
(TF4, TF1) |
UL_TFC11 |
(TF5, TF1) |
Physical channel parameters
DPCH Uplink |
Physical Configuration 1 |
|
Midamble |
256 chips |
|
Codes and time slots |
SF2 x 1 code x 3 time slots |
|
Max. Number of data bits/radio frame |
6480 bits |
|
TFCI code word |
16 bits |
|
TPC |
2 bits |
|
Puncturing Limit |
0.48 |
Downlink TFS:
TFI |
RB5 (384 kbps, 10ms) |
DCCH |
|
TFS |
TF0, bits |
0x336 |
0x148 |
TF1, bits |
1×336 |
1×148 |
|
TF2, bits |
2×336 |
N/A |
|
TF3, bits |
4×336 |
N/A |
|
TF4, bits |
8×336 |
N/A |
|
TF5, bits |
12×336 |
N/A |
Downlink TFCS:
TFCI |
(RB5, DCCH) |
DL_TFC0 |
(TF0, TF0) |
DL_TFC1 |
(TF1, TF0) |
DL_TFC2 |
(TF2, TF0) |
DL_TFC3 |
(TF3, TF0) |
DL_TFC4 |
(TF4, TF0) |
DL_TFC5 |
(TF5, TF0) |
DL_TFC6 |
(TF0, TF1) |
DL_TFC7 |
(TF1, TF1) |
DL_TFC8 |
(TF2, TF1) |
DL_TFC9 |
(TF3, TF1) |
DL_TFC10 |
(TF4, TF1) |
DL_TFC11 |
(TF5, TF1) |
Physical channel parameters
DPCH Downlink |
Physical Configuration 1 |
|
Midamble |
256 chips |
|
Codes and time slots |
SF16 x 8 codes x 3 time slots |
|
Max. Number of data bits/radio frame |
6608 bits |
|
TFCI code word |
16 bits |
|
Puncturing Limit |
0.48 |
Sub-tests:
Sub-test |
Downlink TFCS Under test |
Uplink TFCS Under test |
Implicitly tested |
Restricted UL TFCIs (note 1) |
UL RLC SDU size (bits) (note 2) |
Test data size (bits) (note 2) |
1 |
DL_TFC1 |
UL_TFC1 |
DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6 |
UL_TFC0, UL_TFC1, UL_TFC6, UL_TFC7 |
RB5: 312 |
RB5: 312 |
2 |
DL_TFC2 |
UL_TFC2 |
DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC6, UL_TFC8 |
RB5: 632 |
RB5: 632 |
3 |
DL_TFC3 |
UL_TFC3 |
DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6 |
UL_TFC0, UL_TFC1,UL_TFC3, UL_TFC6, UL_TFC9 |
RB5: 1272 |
RB5: 1272 |
4 |
DL_TFC4 |
UL_TFC4 |
DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6 |
UL_TFC0, UL_TFC1,UL_TFC4, UL_TFC6, UL_TFC10 |
RB5: 2552 |
RB5: 2552 |
5 |
DL_TFC5 |
UL_TFC5 |
DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6 |
UL_TFC0, UL_TFC1,UL_TFC5, UL_TFC6, UL_TFC11 |
RB5: 3832 |
RB5: 3832 |
NOTE 1: UL_TFC0, UL_TFC1 and UL_TFC6 are part of minimum set of TFCIs. NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs. |
See 18.2.1.1 for test procedure.
18.2.2.34.1.4 Test requirements
See 18.2.1.1 for definition of step 10 and step 15.
1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.
2. At step 15 the UE transmitted transport format shall be
– for sub-test 1: RB5/TF1 (1×336).
– for sub-test 2: RB5/TF2 (2×336).
– for sub-test 3: RB5/TF3 (4×336).
– for sub-test 4: RB5/TF4 (8×336).
– for sub-test 5: RB5/TF4 (12×336).
3. At step 15 the UE shall return
– for sub-test 1 to 5: an RLC SDU on RB5 having the same content as the DL RLC SDU sent by the SS.
18.2.2.34.2 Interactive or background / UL:384 DL:384 kbps / PS RAB / 20 ms TTI, Physical Configuration 2
18.2.2.34.2.1 Conformance requirement
See 18.2.2.4.1.
18.2.2.34.2.2 Test purpose
Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.10.3.4.1.34. for the 20 ms TTI, physical configuration 2 case
18.2.2.34.2.3 Method of test
Uplink TFS:
TFI |
RB5 (384 kbps, 20ms) |
DCCH |
|
TFS |
TF0, bits |
0x336 |
0x148 |
TF1, bits |
1×336 |
1×148 |
|
TF2, bits |
2×336 |
N/A |
|
TF3, bits |
4×336 |
N/A |
|
TF4, bits |
8×336 |
N/A |
|
TF5, bits |
12×336 |
N/A |
|
TF6, bits |
16×336 |
N/A |
|
TF7, bits |
20×336 |
N/A |
|
TF8, bits |
24×336 |
N/A |
Uplink TFCS:
TFCI |
(RB5, DCCH) |
UL_TFC0 |
(TF0, TF0) |
UL_TFC1 |
(TF1, TF0) |
UL_TFC2 |
(TF2, TF0) |
UL_TFC3 |
(TF3, TF0) |
UL_TFC4 |
(TF4, TF0) |
UL_TFC5 |
(TF5, TF0) |
UL_TFC6 |
(TF6, TF0) |
UL_TFC7 |
(TF7, TF0) |
UL_TFC8 |
(TF8, TF0) |
UL_TFC9 |
(TF0, TF1) |
UL_TFC10 |
(TF1, TF1) |
UL_TFC11 |
(TF2, TF1) |
UL_TFC12 |
(TF3, TF1) |
UL_TFC13 |
(TF4, TF1) |
UL_TFC14 |
(TF5, TF1) |
UL_TFC15 |
(TF6, TF1) |
UL_TFC16 |
(TF7, TF1) |
UL_TFC17 |
(TF8, TF1) |
Physical channel parameters
DPCH Uplink |
Physical Configuration 2 |
|
Midamble |
256 chips |
|
Codes and time slots |
SF2 x 1 code x 5 timeslots + SF4 x 1 code x 2 timeslots (alt. {SF2 x 1 code + SF4 x 1 code} x 4 timeslots) |
|
Max. Number of data bits/radio frame |
13104 bits |
|
TFCI code word |
16 bits |
|
TPC |
2 bits |
|
Puncturing Limit |
1 |
Downlink TFS:
TFI |
RB5 (384 kbps, 20ms) |
DCCH |
|
TFS |
TF0, bits |
0x336 |
0x148 |
TF1, bits |
1×336 |
1×148 |
|
TF2, bits |
2×336 |
N/A |
|
TF3, bits |
4×336 |
N/A |
|
TF4, bits |
8×336 |
N/A |
|
TF5, bits |
12×336 |
N/A |
|
TF6, bits |
16×336 |
N/A |
|
TF7, bits |
20×336 |
N/A |
|
TF8, bits |
24×336 |
N/A |
Downlink TFCS:
TFCI |
(RB5, DCCH) |
DL_TFC0 |
(TF0, TF0) |
DL_TFC1 |
(TF1, TF0) |
DL_TFC2 |
(TF2, TF0) |
DL_TFC3 |
(TF3, TF0) |
DL_TFC4 |
(TF4, TF0) |
DL_TFC5 |
(TF5, TF0) |
DL_TFC6 |
(TF6, TF0) |
DL_TFC7 |
(TF7, TF0) |
DL_TFC8 |
(TF8, TF0) |
DL_TFC9 |
(TF0, TF1) |
DL_TFC10 |
(TF1, TF1) |
DL_TFC11 |
(TF2, TF1) |
DL_TFC12 |
(TF3, TF1) |
DL_TFC13 |
(TF4, TF1) |
DL_TFC14 |
(TF5, TF1) |
DL_TFC15 |
(TF6, TF1) |
DL_TFC16 |
(TF7, TF1) |
DL_TFC17 |
(TF8, TF1) |
Physical channel parameters
DPCH Downlink |
Physical Configuration 2 |
|
Midamble |
256 chips |
|
Codes and time slots |
SF16 x 6 codes x 4 time slots + SF16 x 4 codes x 1 time slot (alt. SF1 x 1 code x 3 time slots) |
|
Max. Number of data bits/radio frame |
7712 bits (alt. 13232 bits) |
|
TFCI code word |
16 bits |
|
Puncturing Limit |
0.60 (alt. 1) |
Sub-tests:
Sub-test |
Downlink TFCS Under test |
Uplink TFCS Under test |
Implicitly tested |
Restricted UL TFCIs (note 1) |
UL RLC SDU size (bits) (note 2) |
Test data size (bits) (note 2) |
1 |
DL_TFC1 |
UL_TFC1 |
DL_TFC0, DL_TFC9, UL_TFC0, UL_TFC9 |
UL_TFC0, UL_TFC1, UL_TFC9, UL_TFC10 |
RB5: 312 |
RB5: 312 |
2 |
DL_TFC2 |
UL_TFC2 |
DL_TFC0, DL_TFC9, UL_TFC0, UL_TFC9 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC9, UL_TFC11 |
RB5: 632 |
RB5: 632 |
3 |
DL_TFC3 |
UL_TFC3 |
DL_TFC0, DL_TFC9, UL_TFC0, UL_TFC9 |
UL_TFC0, UL_TFC1, UL_TFC3, UL_TFC9, UL_TFC12 |
RB5: 1272 |
RB5: 1272 |
4 |
DL_TFC4 |
UL_TFC4 |
DL_TFC0, DL_TFC9, UL_TFC0, UL_TFC9 |
UL_TFC0, UL_TFC1, UL_TFC4, UL_TFC9, UL_TFC13 |
RB5: 2552 |
RB5: 2552 |
5 |
DL_TFC5 |
UL_TFC5 |
DL_TFC0, DL_TFC9, UL_TFC0, UL_TFC9 |
UL_TFC0, UL_TFC1, UL_TFC5, UL_TFC9, UL_TFC14 |
RB5: 3832 |
RB5: 3832 |
6 |
DL_TFC6 |
UL_TFC6 |
DL_TFC0, DL_TFC9, UL_TFC0, UL_TFC9 |
UL_TFC0, UL_TFC1, UL_TFC6, UL_TFC9, UL_TFC15 |
RB5: 5112 |
RB5: 5112 |
7 |
DL_TFC7 |
UL_TFC7 |
DL_TFC0, DL_TFC9, UL_TFC0, UL_TFC9 |
UL_TFC0, UL_TFC1, UL_TFC7, UL_TFC9, UL_TFC16 |
RB5: 6392 |
RB5: 6392 |
8 |
DL_TFC8 |
UL_TFC8 |
DL_TFC0, DL_TFC9, UL_TFC0, UL_TFC9 |
UL_TFC0, UL_TFC1, UL_TFC8, UL_TFC9, UL_TFC17 |
RB5: 7672 |
RB5: 7672 |
NOTE 1: UL_TFC0, UL_TFC1, and UL_TFC9 are part of minimum set of TFCIs. NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs. |
See 18.2.1.1 for test procedure.
18.2.2.34.2.4 Test requirements
See 18.2.1.1 for definition of step 10 and step 15.
1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.
2. At step 15 the UE transmitted transport format shall be
– for sub-test 1: RB5/TF1 (1×336).
– for sub-test 2: RB5/TF2 (2×336).
– for sub-test 3: RB5/TF3 (4×336).
– for sub-test 4: RB5/TF4 (8×336).
– for sub-test 5: RB5/TF5 (12×336).
– for sub-test 6: RB5/TF6 (16×336).
– for sub-test 7: RB5/TF7 (20×336).
– for sub-test 8: RB5/TF8 (24×336).
3. At step 15 the UE shall return
– for sub-test 1 to 8: an RLC SDU on RB5 having the same content as the DL RLC SDU sent by the SS.
18.2.2.35 Interactive or background / UL:64 DL:2048 kbps / PS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH
18.2.2.35.1 Interactive or background / UL:64 DL:2048 kbps / PS RAB / Payload 320, 10 ms TTI Down Link, Physical Configuration 1
18.2.2.35.1.1 Conformance requirement
See 18.2.2.4.1.
18.2.2.35.1.2 Test purpose
Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.10.3.4.1.35 for the uplink payload 320, the downlink 10 ms TTI, and physical configuration 1 case.
18.2.2.35.1.3 Method of test
Uplink TFS:
TFI |
RB5 (64 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x336 |
0x148 |
TF1, bits |
1×336 |
1×148 |
|
TF2, bits |
2×336 |
N/A |
|
TF3, bits |
3×336 |
N/A |
|
TF4, bits |
4×336 |
N/A |
Uplink TFCS:
TFCI |
(RB5, DCCH) |
UL_TFC0 |
(TF0, TF0) |
UL_TFC1 |
(TF1, TF0) |
UL_TFC2 |
(TF2, TF0) |
UL_TFC3 |
(TF3, TF0) |
UL_TFC4 |
(TF4, TF0) |
UL_TFC5 |
(TF0, TF1) |
UL_TFC6 |
(TF1, TF1) |
UL_TFC7 |
(TF2, TF1) |
UL_TFC8 |
(TF3, TF1) |
UL_TFC9 |
(TF4, TF1) |
Downlink TFS:
TFI |
RB5 (2048 kbps, 10ms) |
DCCH |
|
TFS |
TF0, bits |
0x656 |
0x148 |
TF1, bits |
1×656 |
1×148 |
|
TF2, bits |
2×656 |
N/A |
|
TF3, bits |
4×656 |
N/A |
|
TF4, bits |
8×656 |
N/A |
|
TF5, bits |
12×656 |
N/A |
|
TF6, bits |
16×656 |
N/A |
|
TF7, bits |
20×656 |
N/A |
|
TF8, bits |
24×656 |
N/A |
|
TF9, bits |
28×656 |
N/A |
|
TF10, bits |
31×656 |
N/A |
Downlink TFCS:
TFCI |
(RB5, DCCH) |
DL_TFC0 |
(TF0, TF0) |
DL_TFC1 |
(TF1, TF0) |
DL_TFC2 |
(TF2, TF0) |
DL_TFC3 |
(TF3, TF0) |
DL_TFC4 |
(TF4, TF0) |
DL_TFC5 |
(TF5, TF0) |
DL_TFC6 |
(TF6, TF0) |
DL_TFC7 |
(TF7, TF0) |
DL_TFC8 |
(TF8, TF0) |
DL_TFC9 |
(TF9, TF0) |
DL_TFC10 |
(TF10, TF0) |
DL_TFC11 |
(TF0, TF1) |
DL_TFC12 |
(TF1, TF1) |
DL_TFC13 |
(TF2, TF1) |
DL_TFC14 |
(TF3, TF1) |
DL_TFC15 |
(TF4, TF1) |
DL_TFC16 |
(TF5, TF1) |
DL_TFC17 |
(TF6, TF1) |
DL_TFC18 |
(TF7, TF1) |
DL_TFC19 |
(TF8, TF1) |
DL_TFC20 |
(TF9, TF1) |
DL_TFC21 |
(TF10, TF1) |
Physical channel parameters
DPCH Uplink |
Physical Configuration 1 |
|
Midamble |
256 chips |
|
Codes and time slots |
SF2 x 1 code x 3 time slots |
|
Max. Number of data bits/radio frame |
6480 bits |
|
TFCI code word |
16 bits |
|
TPC |
2 bits |
|
Puncturing Limit |
0.48 |
Sub-tests:
Sub-test |
Downlink TFCS Under Test |
Uplink TFCS Under test |
Implicitly tested |
Restricted UL TFCIs (note 1) |
UL RLC SDU size (bits) (note 2) |
Test data size (bits) (note 2) |
1 |
DL_TFC1 |
UL_TFC1 |
DL_TFC0, DL_TFC11, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC5, UL_TFC6 |
RB5: 632 |
RB5: 632 |
2 |
DL_TFC2 |
UL_TFC2 |
DL_TFC0, DL_TFC11, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1,UL_TFC2, UL_TFC5, UL_TFC7 |
RB5: 1272 |
RB5: 1272 |
3 |
DL_TFC3 |
UL_TFC3 |
DL_TFC0, DL_TFC11, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1,UL_TFC3, UL_TFC5, UL_TFC8 |
RB5: 2872 |
RB5: 2552 |
4 |
DL_TFC4 |
UL_TFC4 |
DL_TFC0, DL_TFC11, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1,UL_TFC4, UL_TFC5, UL_TFC9 |
RB5: 5112 |
RB5: 5112 |
5 |
DL_TFC5 |
UL_TFC4 |
DL_TFC0, DL_TFC11, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1,UL_TFC4, UL_TFC5, UL_TFC9 |
RB5: 7672 |
RB5: 7672 |
6 |
DL_TFC6 |
UL_TFC4 |
DL_TFC0, DL_TFC11, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1,UL_TFC4, UL_TFC5, UL_TFC9 |
RB5: 10232 |
RB5: 10232 |
7 |
DL_TFC7 |
UL_TFC4 |
DL_TFC0, DL_TFC11, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1,UL_TFC4, UL_TFC5, UL_TFC9 |
RB5: 12792 |
RB5: 12792 |
8 |
DL_TFC8 |
UL_TFC4 |
DL_TFC0, DL_TFC11, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1,UL_TFC4, UL_TFC5, UL_TFC9 |
RB5: 15352 |
RB5: 15352 |
9 |
DL_TFC9 |
UL_TFC4 |
DL_TFC0, DL_TFC11, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1,UL_TFC4, UL_TFC5, UL_TFC9 |
RB5: 17912 |
RB5: 17912 |
10 |
DL_TFC10 |
UL_TFC4 |
DL_TFC0, DL_TFC11, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1,UL_TFC4, UL_TFC5, UL_TFC9 |
RB5: 20472 |
RB5: 20472 |
NOTE 1: UL_TFC0, UL_TFC1, and UL_TFC5 are part of minimum set of TFCIs. NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs. |
See 18.2.1.1 for test procedure.
18.2.2.35.1.4 Test requirements
See 18.2.1.1 for definition of step 10 and step 15.
1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.
2. At step 15 the UE transmitted transport format shall be
– for sub-test 1: RB5/TF1 (1×336).
– for sub-test 2: RB5/TF2 (2×336).
– for sub-test 3: RB5/TF3 (3×336).
– for sub-test 4 to 10: RB5/TF4 (4×336).
3. At step 15 the UE shall return
– for sub-test 1, 2, and 4 to 10: an RLC SDU on RB5 having the same content as the DL RLC SDU sent by the SS.
– for sub-test 3: an RLC SDU on RB5 having the same content as 1 times plus 320 lsb’s of the DL RLC SDU sent by the SS.
18.2.2.35.2 Interactive or background / UL:64 DL:2048 kbps / PS RAB / Payload 128, 20 ms TTI Down Link, Physical Configuration 2
18.2.2.35.2.1 Conformance requirement
See 18.2.2.4.1.
18.2.2.35.2.2 Test purpose
Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.10.3.4.1.35 for the uplink payload 128, the downlink 20 ms TTI, and physical configuration 2 case.
18.2.2.35.2.3 Method of test
Uplink TFS:
TFI |
RB5 (64 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x144 |
0x148 |
TF1, bits |
1×144 |
1×148 |
|
TF2, bits |
3×144 |
N/A |
|
TF3, bits |
7×144 |
N/A |
|
TF4, bits |
10×144 |
N/A |
Uplink TFCS:
TFCI |
(RB5, DCCH) |
UL_TFC0 |
(TF0, TF0) |
UL_TFC1 |
(TF1, TF0) |
UL_TFC2 |
(TF2, TF0) |
UL_TFC3 |
(TF3, TF0) |
UL_TFC4 |
(TF4, TF0) |
UL_TFC5 |
(TF0, TF1) |
UL_TFC6 |
(TF1, TF1) |
UL_TFC7 |
(TF2, TF1) |
UL_TFC8 |
(TF3, TF1) |
UL_TFC9 |
(TF4, TF1) |
Downlink TFS:
TFI |
RB5 (2048 kbps, 10ms) |
DCCH |
|
TFS |
TF0, bits |
0x656 |
0x148 |
TF1, bits |
1×656 |
1×148 |
|
TF2, bits |
2×656 |
N/A |
|
TF3, bits |
4×656 |
N/A |
|
TF4, bits |
8×656 |
N/A |
|
TF5, bits |
12×656 |
N/A |
|
TF6, bits |
16×656 |
N/A |
|
TF7, bits |
20×656 |
N/A |
|
TF8, bits |
24×656 |
N/A |
|
TF9, bits |
28×656 |
N/A |
|
TF10, bits |
32×656 |
N/A |
|
TF11, bits |
36×656 |
N/A |
|
TF12, bits |
40×656 |
N/A |
|
TF13, bits |
44×656 |
N/A |
|
TF14, bits |
48×656 |
N/A |
|
TF15, bits |
52×656 |
N/A |
|
TF16, bits |
56×656 |
N/A |
|
TF17, bits |
60×656 |
N/A |
|
TF18, bits |
64×656 |
N/A |
Downlink TFCS:
TFCI |
(RB5, DCCH) |
---|---|
DL_TFC0 |
(TF0, TF0) |
DL_TFC1 |
(TF1, TF0) |
DL_TFC2 |
(TF2, TF0) |
DL_TFC3 |
(TF3, TF0) |
DL_TFC4 |
(TF4, TF0) |
DL_TFC5 |
(TF5, TF0) |
DL_TFC6 |
(TF6, TF0) |
DL_TFC7 |
(TF7, TF0) |
DL_TFC8 |
(TF8, TF0) |
DL_TFC9 |
(TF9, TF0) |
DL_TFC10 |
(TF10, TF0) |
DL_TFC11 |
(TF11, TF0) |
DL_TFC12 |
(TF12, TF0) |
DL_TFC13 |
(TF13, TF0) |
DL_TFC14 |
(TF14, TF0) |
DL_TFC15 |
(TF15, TF0) |
DL_TFC16 |
(TF16, TF0) |
DL_TFC17 |
(TF17, TF0) |
DL_TFC18 |
(TF18, TF0) |
DL_TFC19 |
(TF0, TF1) |
DL_TFC20 |
(TF1, TF1) |
DL_TFC21 |
(TF2, TF1) |
DL_TFC22 |
(TF3, TF1) |
DL_TFC23 |
(TF4, TF1) |
DL_TFC24 |
(TF5, TF1) |
DL_TFC25 |
(TF6, TF1) |
DL_TFC26 |
(TF7, TF1) |
DL_TFC27 |
(TF8, TF1) |
DL_TFC28 |
(TF9, TF1) |
DL_TFC29 |
(TF10, TF1) |
DL_TFC30 |
(TF11, TF1) |
DL_TFC31 |
(TF12, TF1) |
DL_TFC32 |
(TF13, TF1) |
DL_TFC33 |
(TF14, TF1) |
DL_TFC34 |
(TF15, TF1) |
DL_TFC35 |
(TF16, TF1) |
DL_TFC36 |
(TF17, TF1) |
DL_TFC37 |
(TF18, TF1) |
Physical channel parameters
DPCH Downlink |
Physical Configuration 2 |
|
Midamble |
256 chips |
|
Codes and time slots |
SF16 x 13 codes x 4 time slots + SF16 x 12 codes x 7 time slot |
|
Max. Number of data bits/radio frame |
37520 bits (alt. 37504) |
|
TFCI code word |
16 bits (alt. 32 bits) |
|
Puncturing limit |
0.56 |
Sub-tests:
Sub-test |
Downlink TFCS Under Test |
Uplink TFCS Under test |
Implicitly tested |
Restricted UL TFCIs (note 1) |
UL RLC SDU size (bits) (note 2) |
Test data size (bits) (note 2) |
---|---|---|---|---|---|---|
1 |
DL_TFC1 |
UL_TFC1 |
DL_TFC0, DL_TFC19, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1, UL_TFC5, UL_TFC6 |
RB5: 632 |
RB5: 632 |
2 |
DL_TFC2 |
UL_TFC2 |
DL_TFC0, DL_TFC19, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1,UL_TFC2, UL_TFC5, UL_TFC7 |
RB5: 1536 |
RB5: 1272 |
3 |
DL_TFC3 |
UL_TFC3 |
DL_TFC0, DL_TFC19, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1,UL_TFC3, UL_TFC5, UL_TFC8 |
RB5: 2688 |
RB5: 2552 |
4 |
DL_TFC4 |
UL_TFC4 |
DL_TFC0, DL_TFC19, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1,UL_TFC4, UL_TFC5, UL_TFC9 |
RB5: 5112 |
RB5: 5112 |
5 |
DL_TFC5 |
UL_TFC4 |
DL_TFC0, DL_TFC19, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1,UL_TFC4, UL_TFC5, UL_TFC9 |
RB5: 7672 |
RB5: 7672 |
6 |
DL_TFC6 |
UL_TFC4 |
DL_TFC0, DL_TFC19, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1,UL_TFC4, UL_TFC5, UL_TFC9 |
RB5: 10232 |
RB5: 10232 |
7 |
DL_TFC7 |
UL_TFC4 |
DL_TFC0, DL_TFC19, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1,UL_TFC4, UL_TFC5, UL_TFC9 |
RB5: 12792 |
RB5: 12792 |
8 |
DL_TFC8 |
UL_TFC4 |
DL_TFC0, DL_TFC19, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1,UL_TFC4, UL_TFC5, UL_TFC9 |
RB5: 15352 |
RB5: 15352 |
9 |
DL_TFC9 |
UL_TFC4 |
DL_TFC0, DL_TFC19, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1,UL_TFC4, UL_TFC5, UL_TFC9 |
RB5: 17912 |
RB5: 17912 |
10 |
DL_TFC10 |
UL_TFC4 |
DL_TFC0, DL_TFC19, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1,UL_TFC4, UL_TFC5, UL_TFC9 |
RB5: 20472 |
RB5: 20472 |
11 |
DL_TFC11 |
UL_TFC4 |
DL_TFC0, DL_TFC19, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1,UL_TFC4, UL_TFC5, UL_TFC9 |
RB5: 23032 |
RB5: 23032 |
12 |
DL_TFC12 |
UL_TFC4 |
DL_TFC0, DL_TFC19, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1,UL_TFC4, UL_TFC5, UL_TFC9 |
RB5: 25592 |
RB5: 25592 |
13 |
DL_TFC13 |
UL_TFC4 |
DL_TFC0, DL_TFC19, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1,UL_TFC4 UL_TFC5, UL_TFC9 |
RB5: 28152 |
RB5: 28152 |
14 |
DL_TFC14 |
UL_TFC4 |
DL_TFC0, DL_TFC19, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1,UL_TFC4, UL_TFC5, UL_TFC9 |
RB5: 30712 |
RB5: 30712 |
15 |
DL_TFC15 |
UL_TFC4 |
DL_TFC0, DL_TFC19, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1,UL_TFC4, UL_TFC5, UL_TFC9 |
RB5: 33272 |
RB5: 33272 |
16 |
DL_TFC16 |
UL_TFC4 |
DL_TFC0, DL_TFC19, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1,UL_TFC4, UL_TFC5, UL_TFC9 |
RB5: 35832 |
RB5: 35832 |
17 |
DL_TFC17 |
UL_TFC4 |
DL_TFC0, DL_TFC19, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1,UL_TFC4 UL_TFC5, UL_TFC9 |
RB5: 38392 |
RB5: 38392 |
18 |
DL_TFC18 |
UL_TFC4 |
DL_TFC0, DL_TFC19, UL_TFC0, UL_TFC5 |
UL_TFC0, UL_TFC1,UL_TFC4, UL_TFC5, UL_TFC9 |
RB5: 40952 |
RB5: 40952 |
NOTE 1: UL_TFC0, UL_TFC1, and UL_TFC5 are part of minimum set of TFCIs. NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs. |
See 18.2.1.1 for test procedure.
18.2.2.35.2.4 Test requirements
See 18.2.1.1 for definition of step 10 and step 15.
1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.
2. At step 15 the UE transmitted transport format shall be
– for sub-test 1: RB5/TF1 (1×144).
– for sub-test 2: RB5/TF2 (3×144).
– for sub-test 3: RB5/TF3 (7×144).
– for sub-test 4 to 18: RB5/TF4 (10×144).
3. At step 15 the UE shall return
– for sub-test 1, and 4 to 18: an RLC SDU on RB5 having the same content as the DL RLC SDU sent by the SS.
– for sub-test 2: an RLC SDU on RB5 having the same content as 1 times plus 264 lsb’s of the DL RLC SDU sent by the SS.
– for sub-test 3: an RLC SDU on RB5 having the same content as 1 times plus 136 lsb’s of the DL RLC SDU sent by the SS.