14.2.58a Streaming / unknown / UL:16 DL:128 kbps / PS RAB + Interactive or background / UL:8 DL:8 kbps / PS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH.

34.123-13GPPPart 1: Protocol conformance specificationRelease 15TSUser Equipment (UE) conformance specification

14.2.58a.1 Conformance requirement

See 14.2.4.1.

14.2.58a.2 Test purpose

Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.10.2.4.1.58a.

14.2.58a.3 Method of test

See 14.1.2 for test procedure. However, in this test the RM attribute values used shall be derived separately in the UL and DL as the mid-values of the RM attribute value ranges as specified by the reference radio bearer configuration.

Specific Message Content:

Use the RADIO BEARER SETUP message as defined in [9] TS 34.108 clause 9, with the following exceptions:

Information Element

Value/remark

– RAB information for setup

– RAB info

(AM DTCH for PS domain)

– RAB identity

0000 0101B

The first/ leftmost bit of the bit string contains the most significant bit of the RAB identity.

– CN domain identity

PS domain

– NAS Synchronization Indicator

Not Present

– Re-establishment timer

useT315

– RB information to setup

– RB identity

20

– PDCP Info

Not Present

– CHOICE RLC info type

RLC info

– CHOICE Uplink RLC mode

AM RLC

– Transmission RLC discard

– CHOICE SDU discard mode

No Discard

– MAX_DAT

15

– Transmission window size

128

– Timer_RST

500

– Max_RST

4

– Polling info

– Timer_poll_prohibit

200

– Timer_poll

200

– Poll_PDU

Not Present

– Poll_SDU

1

– Last transmission PDU poll

TRUE

– Last retransmission PDU poll

TRUE

– Poll_Windows

99

– Timer_poll_periodic

Not Present

– CHOICE Downlink RLC mode

AM RLC

– In-sequence delivery

TRUE

– Receiving window size

128

– Downlink RLC status info

– Timer_status_prohibit

200

– Timer_EPC

Not Present

– Missing PDU indicator

TRUE

– Timer_STATUS_periodic

Not Present

– RB mapping info

– Information for each multiplexing option

2 RBMuxOptions

– RLC logical channel mapping indicator

Not Present

– Number of uplink RLC logical channels

1

– Uplink transport channel type

DCH

– UL Transport channel identity

1

– Logical channel identity

Not Present

– CHOICE RLC size list

Configured

– MAC logical channel priority

8

– Downlink RLC logical channel info

– Number of downlink RLC logical channels

1

– Downlink transport channel type

DCH

– DL DCH Transport channel identity

6

– DL DSCH Transport channel identity

Not Present

– Logical channel identity

Not Present

– RLC logical channel mapping indicator

Not Present

– Number of uplink RLC logical channels

1

– Uplink transport channel type

RACH

– UL Transport channel identity

Not Present

– Logical channel identity

7

– CHOICE RLC size list

Explicit list

– RLC size index

Reference to TS34.108 clause 6 Parameter Set

– MAC logical channel priority

8

– Downlink RLC logical channel info

– Number of downlink RLC logical channels

1

– Downlink transport channel type

FACH

– DL DCH Transport channel identity

Not Present

– DL DSCH Transport channel identity

Not Present

– Logical channel identity

7

– RAB identity

0000 0110B

The first/ leftmost bit of the bit string contains the most significant bit of the RAB identity.

– CN domain identity

PS domain

– NAS Synchronization Indicator

Not Present

– Re-establishment timer

useT315

– RB information to setup

– RB identity

22

– PDCP info

Not Present

– CHOICE RLC info type

RLC info

– CHOICE Uplink RLC mode

AM RLC

– Transmission RLC discard

– CHOICE SDU discard mode

No Discard

– MAX_DAT

15

– Transmission window size

128

– Timer_RST

500

– Max_RST

4

– Polling info

– Timer_poll_prohibit

200

– Timer_poll

200

– Poll_PDU

Not Present

– Poll_SDU

1

– Last transmission PDU poll

TRUE

– Last retransmission PDU poll

TRUE

– Poll_Windows

99

– Timer_poll_periodic

Not Present

– CHOICE Downlink RLC mode

AM RLC

– In-sequence delivery

TRUE

– Receiving window size

128

– Downlink RLC status info

– Timer_status_prohibit

200

– Timer_EPC

Not Present

– Missing PDU indicator

TRUE

– Timer_STATUS_periodic

Not Present

– RB mapping info

– Information for each multiplexing option

2 RBMuxOptions

– RLC logical channel mapping indicator

Not Present

– Number of uplink RLC logical channels

1

– Uplink transport channel type

DCH

– UL Transport channel identity

2

– Logical channel identity

Not Present

– CHOICE RLC size list

Configured

– MAC logical channel priority

8

– Downlink RLC logical channel info

– Number of downlink RLC logical channels

1

– Downlink transport channel type

DCH

– DL DCH Transport channel identity

7

– DL DSCH Transport channel identity

Not Present

– Logical channel identity

Not Present

– RLC logical channel mapping indicator

Not Present

– Number of uplink RLC logical channels

1

– Uplink transport channel type

RACH

– UL Transport channel identity

Not Present

– Logical channel identity

8

– CHOICE RLC size list

Explicit list

– RLC size index

Reference to TS34.108 clause 6 Parameter Set

– MAC logical channel priority

8

– Downlink RLC logical channel info

– Number of downlink RLC logical channels

1

– Downlink transport channel type

FACH

– DL DCH Transport channel identity

Not Present

– DL DSCH Transport channel identity

Not Present

– Logical channel identity

8

Added or Reconfigured UL TrCH information

2 DCH added, 1 DCH reconfigured

– Uplink transport channel type

DCH

– UL Transport channel identity

1

– TFS

– CHOICE Transport channel type

Dedicated transport channels

– Dynamic Transport format information

– RLC Size

Reference to TS34.108 clause 6.10 Parameter Set

– Number of TBs and TTI List

(This IE is repeated for TFI number.)

– Transmission Time Interval

Not Present

– Number of Transport blocks

Reference to TS34.108 clause 6.10 Parameter Set

– CHOICE Logical Channel list

All

– Semi-static Transport Format information

– Transmission time interval

Reference to TS34.108 clause 6.10 Parameter Set

– Type of channel coding

Reference to TS34.108 clause 6.10 Parameter Set

– Coding Rate

Reference to TS34.108 clause 6.10 Parameter Set

– Rate matching attribute

Reference to TS34.108 clause 6.10 Parameter Set

– CRC size

Reference to TS34.108 clause 6.10 Parameter Set

– Uplink transport channel type

DCH

– UL Transport channel identity

2

– TFS

– CHOICE Transport channel type

Dedicated transport channels

– Dynamic Transport format information

– RLC Size

Reference to TS34.108 clause 6.10 Parameter Set

– Number of TBs and TTI List

(This IE is repeated for TFI number.)

– Transmission Time Interval

Not Present

– Number of Transport blocks

Reference to TS34.108 clause 6.10 Parameter Set

– CHOICE Logical Channel list

All

– Semi-static Transport Format information

– Transmission time interval

Reference to TS34.108 clause 6.10 Parameter Set

– Type of channel coding

Reference to TS34.108 clause 6.10 Parameter Set

– Coding Rate

Reference to TS34.108 clause 6.10 Parameter Set

– Rate matching attribute

Reference to TS34.108 clause 6.10 Parameter Set

– CRC size

Reference to TS34.108 clause 6.10 Parameter Set

– Uplink transport channel type

DCH

– UL Transport channel identity

5

– TFS

– CHOICE Transport channel type

Dedicated transport channels

– Dynamic Transport format information

– RLC Size

Reference to TS34.108 clause 6.10 Parameter Set

– Number of TBs and TTI List

(This IE is repeated for TFI number.)

– Transmission Time Interval

Not Present

– Number of Transport blocks

Reference to TS34.108 clause 6.10 Parameter Set

– CHOICE Logical Channel list

All

– Semi-static Transport Format information

– Transmission time interval

Reference to TS34.108 clause 6.10 Parameter Set

– Type of channel coding

Reference to TS34.108 clause 6.10 Parameter Set

– Coding Rate

Reference to TS34.108 clause 6.10 Parameter Set

– Rate matching attribute

Reference to TS34.108 clause 6.10 Parameter Set

– CRC size

Reference to TS34.108 clause 6.10 Parameter Set

Added or Reconfigured DL TrCH information

3 TrCHs(DCH for DCCH and DCH for DTCH)

– Downlink transport channel type

DCH

– DL Transport channel identity

6

– CHOICE DL parameters

Explicit

– TFS

– CHOICE Transport channel type

Dedicated transport channel

– Dynamic transport format information

– RLC Size

Reference to TS34.108 clause 6.10 Parameter Set

– Number of TBs and TTI List

(This IE is repeated for TFI number.)

– Transmission Time Interval

Not Present

– Number of Transport blocks

Reference to TS34.108 clause 6.10 Parameter Set

– CHOICE Logical Channel list

All

– Semi-static Transport Format information

– Transmission time interval

Reference to TS34.108 clause 6.10 Parameter Set

– Type of channel coding

Reference to TS34.108 clause 6.10 Parameter Set

– Coding Rate

Reference to TS34.108 clause 6.10 Parameter Set

– Rate matching attribute

Reference to TS34.108 clause 6.10 Parameter Set

– CRC size

Reference to TS34.108 clause 6.10 Parameter Set

– DCH quality target

– BLER Quality value

-2.0

– Downlink transport channel type

DCH

– DL Transport channel identity

7

– CHOICE DL parameters

Explicit

– TFS

– CHOICE Transport channel type

Dedicated transport channel

– Dynamic transport format information

– RLC Size

Reference to TS34.108 clause 6.10 Parameter Set

– Number of TBs and TTI List

(This IE is repeated for TFI number.)

– Transmission Time Interval

Not Present

– Number of Transport blocks

Reference to TS34.108 clause 6.10 Parameter Set

– CHOICE Logical Channel list

All

– Semi-static Transport Format information

– Transmission time interval

Reference to TS34.108 clause 6.10 Parameter Set

– Type of channel coding

Reference to TS34.108 clause 6.10 Parameter Set

– Coding Rate

Reference to TS34.108 clause 6.10 Parameter Set

– Rate matching attribute

Reference to TS34.108 clause 6.10 Parameter Set

– CRC size

Reference to TS34.108 clause 6.10 Parameter Set

– DCH quality target

– BLER Quality value

-2.0

– Downlink transport channel type

DCH

– DL Transport channel identity

10

– CHOICE DL parameters

Explicit

– TFS

– CHOICE Transport channel type

Dedicated transport channel

– Dynamic transport format information

– RLC Size

Reference to TS34.108 clause 6.10 Parameter Set

– Number of TBs and TTI List

(This IE is repeated for TFI number.)

– Transmission Time Interval

Not Present

– Number of Transport blocks

Reference to TS34.108 clause 6.10 Parameter Set

– CHOICE Logical Channel list

All

– Semi-static Transport Format information

– Transmission time interval

Reference to TS34.108 clause 6.10 Parameter Set

– Type of channel coding

Reference to TS34.108 clause 6.10 Parameter Set

– Coding Rate

Reference to TS34.108 clause 6.10 Parameter Set

– Rate matching attribute

Reference to TS34.108 clause 6.10 Parameter Set

– CRC size

Reference to TS34.108 clause 6.10 Parameter Set

– DCH quality target

– BLER Quality value

-2.0

Uplink TFS:

TFI

RB5 uplink (16 kbps,

20 ms TTI)

RB6

(8 kbps)

DCCH

TFS

TF0, bits

0x336

0x336

0x148

TF1, bits

1×336

1×336

1×148

Uplink TFCS:

TFCI

(RB5, RB6, DCCH)

UL_TFC0

(TF0, TF0, TF0)

UL_TFC1

(TF1, TF0, TF0)

UL_TFC2

(TF0, TF1, TF0)

UL_TFC3

(TF1, TF1, TF0)

UL_TFC4

(TF0, TF0, TF1)

UL_TFC5

(TF1, TF0, TF1)

UL_TFC6

(TF0, TF1, TF1)

UL_TFC7

(TF1, TF1, TF1)

Downlink TFS:

TFI

RB5
(128 kbps,

20 ms TTI)

RB6
(8 kbps)

DCCH

TFS

TF0, bits

0x656

0x336

0x148

TF1, bits

1×656

1×336

1×148

TF2, bits

2×656

N/A

N/A

TF3, bits

3×656

N/A

N/A

TF4, bits

4×656

N/A

N/A

Downlink TFCS:

TFCI

(RB5, RB6, DCCH)

DL_TFC0

(TF0, TF0, TF0)

DL_TFC1

(TF1, TF0, TF0)

DL_TFC2

(TF2, TF0, TF0)

DL_TFC3

(TF3, TF0, TF0)

DL_TFC4

(TF4, TF0, TF0)

DL_TFC5

(TF0, TF1, TF0)

DL_TFC6

(TF1, TF1, TF0)

DL_TFC7

(TF2, TF1, TF0)

DL_TFC8

(TF3, TF1, TF0)

DL_TFC9

(TF4, TF1, TF0)

DL_TFC10

(TF0, TF0, TF1)

DL_TFC11

(TF1, TF0, TF1)

DL_TFC12

(TF2, TF0, TF1)

DL_TFC13

(TF3, TF0, TF1)

DL_TFC14

(TF4, TF0, TF1)

DL_TFC15

(TF0, TF1, TF1)

DL_TFC16

(TF1, TF1, TF1)

DL_TFC17

(TF2, TF1, TF1)

DL_TFC18

(TF3, TF1, TF1)

DL_TFC19

(TF4, TF1, TF1)

Sub-tests:

Sub-test

Downlink TFCS

Under

Test

Uplink TFCS

Under test

Implicitly tested

Restricted UL TFCIs

(note 1)

UL RLC SDU size

(bits)

(note 2)

Test data size

(bits)

(note 2)

1

DL_TFC1,

DL_TFC11

UL_TFC1, UL_TFC5

DL_TFC0, DL_TFC10,

UL_TFC0, UL_TFC4

UL_TFC0,
UL_TFC1,

UL_TFC2,

UL_TFC4,
UL_TFC5

RB5: 312
RB6: 312

RB5: 632

RB6: no data

2

DL_TFC2,

DL_TFC12

UL_TFC1, UL_TFC5

DL_TFC0, DL_TFC1,

DL_TFC10,

UL_TFC0, UL_TFC4

UL_TFC0,
UL_TFC1,

UL_TFC2,

UL_TFC4,
UL_TFC5

RB5: 312
RB6: 312

RB5: 1272

RB6: no data

3

DL_TFC3, DL_TFC13

UL_TFC1, UL_TFC5

DL_TFC0, DL_TFC1,

DL_TFC10,

UL_TFC0, UL_TFC4

UL_TFC0,
UL_TFC1,

UL_TFC2,

UL_TFC4,
UL_TFC5

RB5: 312
RB6: 312

RB5: 1912

RB6: no data

4

DL_TFC4, DL_TFC14

UL_TFC1, UL_TFC5

DL_TFC0,

DL_TFC1, DL_TFC10,

UL_TFC0, UL_TFC4

UL_TFC0,
UL_TFC1,

UL_TFC2,

UL_TFC4,
UL_TFC5

RB5: 312
RB6: 312

RB5: 2552

RB6: no data

5

DL_TFC5, DL_TFC15

UL_TFC2, UL_TFC6

DL_TFC0, DL_TFC10,

UL_TFC0, UL_TFC4

UL_TFC0,
UL_TFC1,

UL_TFC2,
UL_TFC4,
UL_TFC6

RB5: 312

RB6: 312

RB5: no data

RB6: 312

6

DL_TFC6,

DL_TFC16

UL_TFC3, UL_TFC7

DL_TFC0, DL_TFC1,

DL_TFC5,

DL_TFC10,

UL_TFC0, UL_TFC4

UL_TFC0,
UL_TFC1,
UL_TFC2,
UL_TFC3,
UL_TFC4,
UL_TFC5,
UL_TFC6,

UL_TFC7

RB5: 312

RB6: 312

RB5: 632

RB6: 312

7

DL_TFC7,

DL_TFC17

UL_TFC3, UL_TFC7

DL_TFC0, DL_TFC1,

DL_TFC5, DL_TFC6,

DL_TFC10,

UL_TFC0, UL_TFC4

UL_TFC0,
UL_TFC1,
UL_TFC2,
UL_TFC3,
UL_TFC4,
UL_TFC5,
UL_TFC6,

UL_TFC7

RB5: 312

RB6: 312

RB5: 1272

RB6: 312

8

DL_TFC8, DL_TFC18

UL_TFC3, UL_TFC7

DL_TFC0, DL_TFC1,

DL_TFC5, DL_TFC6,

DL_TFC10,

UL_TFC0, UL_TFC4

UL_TFC0,
UL_TFC1,
UL_TFC2,

UL_TFC3,
UL_TFC4,
UL_TFC5,
UL_TFC6,

UL_TFC7

RB5: 312

RB6: 312

RB5: 1912

RB6: 312

9

DL_TFC9, DL_TFC19

UL_TFC3, UL_TFC7

DL_TFC0, DL_TFC1,

DL_TFC5, DL_TFC6,

DL_TFC10,

UL_TFC0, UL_TFC4

UL_TFC0,
UL_TFC1,
UL_TFC2,

UL_TFC3,
UL_TFC4,
UL_TFC5,
UL_TFC6,

UL_TFC7

RB5: 312

RB6: 312

RB5: 2552

RB6: 312

NOTE 1: UL_TFC0, UL_TFC1, UL_TFC2 and UL_TFC4 are part of minimum set of TFCIs.

NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs.
RB5: Test data size has been set to the payload size of the DL TF under test minus 8 bits (size of 7 bit length indicator and expansion bit). The UL RLC SDU size has been set equal to the size of the UL TF under test minus 8 bits (the size of a 7 bit length indicator and expansion bit).
RB6: Test data size has been set to the payload size of the DL TF under test minus 8 bits (size of 7 bit length indicator and expansion bit). The UL RLC SDU size has been set equal to the size of the uplink TF under test minus 8 bits (the size of a 7 bit length indicator and expansion bit).

14.2.58a.4 Test requirements

See 14.1.2 for definition of step 10 and step 15.

1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.

2. At step 15a and step 15b the UE transmitted transport format shall be within the set of restricted TFCIs as specified for the actual sub-test.

3. At step 15a and step 15b the UE shall return

– for sub-test 1, 2, 3 and 4: RLC SDUs on RB5 having the first 312 bits equal to the content of the test data sent by the SS in downlink; and no data shall be received on RB6.

– for sub-test 5: RLC SDUs on RB6 having the same content as sent by the SS; and no data shall be received on RB5.

– for sub-test 6, 7, 8 and 9: RLC SDUs on RB5 having the first 312 bits equal to the content of the test data sent by the SS in downlink; and RLC SDUs on RB6 having the same content as sent by the SS.

4. At step 15b the UE shall send at least one MEASUREMENT REPORT message.