14.2.51a Conversational / unknown / UL:64 DL:64 kbps / CS RAB + Interactive or Background / UL:8 DL:8 kbps / PS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH.
34.123-13GPPPart 1: Protocol conformance specificationRelease 15TSUser Equipment (UE) conformance specification
14.2.51a.1 Conversational / unknown / UL:64 DL:64 kbps / CS RAB / 20 ms TTI + Interactive or background / UL:8 DL:8 kbps / PS RAB
14.2.51a.1.1 Conformance requirement
See 14.2.4.1.
14.2.51a.1.2 Test purpose
Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.10.2.4.1.51a for the 20 ms TTI case.
14.2.51a.1.3 Method of test
Initial Conditions
The following RLC Info parameter values for the Conversational / unknown / UL:64 DL:64 kbps / CS RAB shall be set by the SS:
Uplink RLC |
|
TM RLC |
|
Transmission RLC discard |
|
CHOICE SDU Discard Mode |
|
Timer based no explicit |
|
Timer_discard |
100ms |
Segmentation indication |
FALSE |
Downlink RLC |
|
TM RLC |
|
Segmentation indication |
FALSE |
NOTE: ‘Timer based discard without explicit signalling’ is configured in uplink to secure that the UE will be able to return data in uplink for the case when the UE test loop function, due to processing delays, will not deliver the SDUs in one and the same TTI, but instead in two subsequent TTIs. |
See 14.1.2 for test procedure.
Uplink TFS:
TFI |
RB5 (Conv. 64 kbps) |
RB6 (I/B 8 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x640 |
0x336 |
0x148 |
TF1, bits |
2×640 |
1×336 |
1×148 |
Uplink TFCS:
TFCI |
(RB5, RB6, DCCH) |
UL_TFC0 |
(TF0, TF0, TF0) |
UL_TFC1 |
(TF1, TF0, TF0) |
UL_TFC2 |
(TF0, TF1, TF0) |
UL_TFC3 |
(TF1, TF1, TF0) |
UL_TFC4 |
(TF0, TF0, TF1) |
UL_TFC5 |
(TF1, TF0, TF1) |
UL_TFC6 |
(TF0, TF1, TF1) |
UL_TFC7 |
(TF1, TF1, TF1) |
Downlink TFS:
TFI |
RB5 (Conv. 64 kbps) |
RB6 (I/B 8kbps) |
DCCH |
|
TFS |
TF0, bits |
0x640 |
0x336 |
0x148 |
TF1, bits |
2×640 |
1×336 |
1×148 |
Downlink TFCS:
TFCI |
(RB5, RB6, DCCH) |
DL_TFC0 |
(TF0, TF0, TF0) |
DL_TFC1 |
(TF1, TF0, TF0) |
DL_TFC2 |
(TF0, TF1, TF0) |
DL_TFC3 |
(TF1, TF1, TF0) |
DL_TFC4 |
(TF0, TF0, TF1) |
DL_TFC5 |
(TF1, TF0, TF1) |
DL_TFC6 |
(TF0, TF1, TF1) |
DL_TFC7 |
(TF1, TF1, TF1) |
Sub-tests:
Sub-test |
Downlink TFCS Under Test |
Uplink TFCS Under test |
Implicitly tested |
Restricted UL TFCIs (note 1) |
UL RLC SDU size (bits) (note 2) |
Test data size (bits) (note 2) |
---|---|---|---|---|---|---|
1 |
DL_ TFC2 DL_ TFC6 |
UL_ TFC2 UL_ TFC6 |
DL_TFC0, DL_TFC4, UL_TFC0, UL_TFC4, |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC4, UL_TFC6 |
RB5: 640 RB6: 312 |
RB5: No data RB6: 312 |
2 |
DL_ TFC1 DL_ TFC5 |
UL_ TFC1 UL_ TFC5 |
DL_TFC0, DL_TFC4, UL_TFC0, UL_TFC4, |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC4, UL_TFC5 |
RB5: 640 RB6: 312 |
RB5: 2×640 RB6: No data |
3 |
DL_TFC3 DL_TFC7 |
UL_TFC3 UL_TFC7 |
DL_TFC0, DL_TFC4, UL_TFC0, UL_TFC4, |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3, UL_TFC4, UL_TFC5, UL_TFC6, UL_TFC7 |
RB5: 640 RB6: 312 |
RB5: 2×640 RB6: 312 |
NOTE 1: UL_TFC0, UL_TFC1, UL_TFC2_and UL_TFC4 are part of minimum set of TFCIs NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs. |
14.2.51a.1.4 Test requirements
See 14.1.2 for definition of step 10 and step 15.
1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.
2. At step 15a and step 15b the UE transmitted transport format shall be within the set of restricted TFCIs as specified for the actual sub-test.
3. At step 15a and step 15b the UE shall return
- for sub-test 1: RLC SDUs on RB6 having the same content as sent by SS; and no data shall be received on RB5.
– for sub-test 2: RLC SDUs on RB5 having the same content as sent by SS; and no data shall be received on RB6.
– for sub-test 3: RLC SDUs on RB5 and RB6 having the same content as sent by SS.
4. At step 15b the UE shall send at least one MEASUREMENT REPORT message.
14.2.51a.2 Conversational / unknown / UL:64 DL:64 kbps / CS RAB / 40 ms TTI + Interactive or background / UL:8 DL:8 kbps / PS RAB
14.2.51a.2.1 Conformance requirement
See 14.2.4.1.
14.2.51a.2.2 Test purpose
Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.10.2.4.1.51a for the 40 ms TTI case.
14.2.51a.2.3 Method of test
Initial Conditions
The following RLC Info parameter values for the Conversational / unknown / UL:64 DL:64 kbps / CS RAB shall be set by the SS:
Uplink RLC |
|
TM RLC |
|
Transmission RLC discard |
|
CHOICE SDU Discard Mode |
|
Timer based no explicit |
|
Timer_discard |
100ms |
Segmentation indication |
FALSE |
Downlink RLC |
|
TM RLC |
|
Segmentation indication |
FALSE |
NOTE: ‘Timer based discard without explicit signalling’ is configured in uplink to secure that the UE will be able to return data in uplink for the case when the UE test loop function, due to processing delays, will not deliver the SDUs in one and the same TTI, but instead in two subsequent TTIs. |
See 14.1.2 for test procedure.
Uplink TFS:
TFI |
RB5 (Conv. 64 kbps) |
RB6 (I/B 8 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x640 |
0x336 |
0x148 |
TF1, bits |
4×640 |
1×336 |
1×148 |
Uplink TFCS:
TFCI |
(RB5, RB6, DCCH) |
UL_TFC0 |
(TF0, TF0, TF0) |
UL_TFC1 |
(TF0, TF1, TF0) |
UL_TFC2 |
(TF1, TF0, TF0) |
UL_TFC3 |
(TF1, TF1, TF0) |
UL_TFC4 |
(TF0, TF0, TF1) |
UL_TFC5 |
(TF0, TF1, TF1) |
UL_TFC6 |
(TF1, TF0, TF1) |
UL_TFC7 |
(TF1, TF1, TF1) |
Downlink TFS:
TFI |
RB5 (Conv. 64 kbps) |
RB6 (I/B 64 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x640 |
0x336 |
0x148 |
TF1, bits |
4×640 |
1×336 |
1×148 |
Downlink TFCS:
TFCI |
(RB5, RB6, DCCH) |
DL_TFC0 |
(TF0, TF0, TF0) |
DL_TFC1 |
(TF0, TF1, TF0) |
DL_TFC2 |
(TF1, TF0, TF0) |
DL_TFC3 |
(TF1, TF1, TF0) |
DL_TFC4 |
(TF0, TF0, TF1) |
DL_TFC5 |
(TF0, TF1, TF1) |
DL_TFC6 |
(TF1, TF0, TF1) |
DL_TFC7 |
(TF1, TF1, TF1) |
Sub-tests:
Sub-test |
Downlink TFCS Under Test |
Uplink TFCS Under test |
Implicitly tested |
Restricted UL TFCIs (note1) |
UL RLC SDU size (bits) Note 2 |
Test data size (bits) Note 2 |
---|---|---|---|---|---|---|
1 |
DL_TFC1 DL_TFC5, |
UL_TFC1 UL_TFC5 |
DL_TFC0, DL_TFC4, UL_TFC0, UL_TFC4, |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC4, UL_TFC5 |
RB5: 640 RB6: 312 |
RB5: No data RB6: 312 |
2 |
DL_TFC2 DL_TFC5, |
UL_TFC2 UL_TFC6 |
DL_TFC0, DL_TFC4, UL_TFC0, UL_TFC4, |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC4, UL_TFC6 |
RB5: 640 RB6: 312 |
RB5: 4×640 RB6: No data |
3 |
DL_TFC3 DL_TFC5, |
UL_TFC3 UL_TFC7 |
DL_TFC0, DL_TFC4, UL_TFC0, UL_TFC4, |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3, UL_TFC4, UL_TFC5, UL_TFC6, UL_TFC7 |
RB5: 640 RB6: 312 |
RB5: 4×640 RB6: 312 |
NOTE1: UL_TFC0, UL_TFC1, UL_TFC2_and UL_TFC4 are part of minimum set of TFCIs NOTE2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs. |
14.2.51a.2.4 Test requirements
See 14.1.2 for definition of step 10 and step 15.
1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.
2. At step 15a and step 15b the UE transmitted transport format shall be within the set of restricted TFCIs as specified for the actual sub-test.
3. At step 15a and step 15b the UE shall return
- for sub-test 1: RLC SDUs on RB6 having the same content as sent by SS; and no data shall be received on RB5.
– for sub-test 2: RLC SDUs on RB5 having the same content as sent by SS; and no data shall be received on RB6.
– for sub-test 3: RLC SDUs on RB5 and RB6 having the same content as sent by SS.
4. At step 15b the UE shall send at least one MEASUREMENT REPORT message.