14.2.49 Conversational / speech / UL:12.2 DL:12.2 kbps / CS RAB + Conversational / unknown / UL:64 DL:64 kbps / CS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH

34.123-13GPPPart 1: Protocol conformance specificationRelease 15TSUser Equipment (UE) conformance specification

14.2.49.1 Conversational / speech / UL:12.2 DL:12.2 kbps / CS RAB + Conversational / unknown / UL:64 DL:64 kbps / CS RAB / 20 ms TTI

14.2.49.1.1 Conformance requirement

See 14.2.4.1.

14.2.49.1.2 Test purpose

Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.10.2.4.1.49 for the 20 ms TTI case.

14.2.49.1.3 Method of test

See 14.1.2 for test procedure. However, in this test the RM attribute values used shall be derived separately in the UL and DL as the mid-values of the RM attribute value ranges as specified by the reference radio bearer configuration.

Initial Conditions

The following RLC Info parameter values shall be set by the SS for the Conversational / unknown / UL:64 DL:64 kbps / CS RAB (RB8):

Uplink RLC

TM RLC

Transmission RLC discard

CHOICE SDU Discard Mode

Timer based no explicit

Timer_discard

100ms

Segmentation indication

FALSE

Downlink RLC

TM RLC

Segmentation indication

FALSE

NOTE: Timer based discard without explicit signalling is used in uplink to secure that the UE will be able to return data for the case when the UE test loop function will not deliver all the SDUs in one and the same TTI .

Uplink TFS:

TFI

RB5

(RAB subflow #1)

RB6

(RAB subflow #2)

RB7

(RAB subflow #3)

RB8

(64 kbps, 20 ms TTI)

DCCH

TFS

TF0, bits

0x81

0x103

0x60

0x640

0x148

TF1, bits

1×39

1×103

1×60

2×640

1×148

TF2, bits

1×81

N/A

N/A

N/A

N/A

Uplink TFCS:

TFCI

(RB5, RB6, RB7, RB8, DCCH)

UL_TFC0

(TF0, TF0, TF0, TF0, TF0)

UL_TFC1

(TF1, TF0, TF0, TF0, TF0)

UL_TFC2

(TF2, TF1, TF1, TF0, TF0)

UL_TFC3

(TF0, TF0, TF0, TF1, TF0)

UL_TFC4

(TF1, TF0, TF0, TF1, TF0)

UL_TFC5

(TF2, TF1, TF1, TF1, TF0)

UL_TFC6

(TF0, TF0, TF0, TF0, TF1)

UL_TFC7

(TF1, TF0, TF0, TF0, TF1)

UL_TFC8

(TF2, TF1, TF1, TF0, TF1)

UL_TFC9

(TF0, TF0, TF0, TF1, TF1)

UL_TFC10

(TF1, TF0, TF0, TF1, TF1)

UL_TFC11

(TF2, TF1, TF1, TF1, TF1)

Downlink TFS:

RB5

(RAB subflow #1)

RB6

(RAB subflow #2)

RB7

(RAB subflow #3)

RB8

(64 kbps, 20 ms TTI)

DCCH

TFS

TF0, bits

1×0

0x103

0x60

0x640

0x148

TF1, bits

1×39

1×103

1×60

2×640

1×148

TF2, bits

1×81

N/A

N/A

N/A

N/A

Downlink TFCS:

TFCI

(RB5, RB6, RB7, RB8, DCCH)

DL_TFC0

(TF0, TF0, TF0, TF0, TF0)

DL_TFC1

(TF1, TF0, TF0, TF0, TF0)

DL_TFC2

(TF2, TF1, TF1, TF0, TF0)

DL_TFC3

(TF0, TF0, TF0, TF1, TF0)

DL_TFC4

(TF1, TF0, TF0, TF1, TF0)

DL_TFC5

(TF2, TF1, TF1, TF1, TF0)

DL_TFC6

(TF0, TF0, TF0, TF0, TF1)

DL_TFC7

(TF1, TF0, TF0, TF0, TF1)

DL_TFC8

(TF2, TF1, TF1, TF0, TF1)

DL_TFC9

(TF0, TF0, TF0, TF1, TF1)

DL_TFC10

(TF1, TF0, TF0, TF1, TF1)

DL_TFC11

(TF2, TF1, TF1, TF1, TF1)

Sub-tests:

Sub-test

Downlink TFCS

Under

Test

Uplink TFCS

Under test

Implicitly tested

Restricted UL TFCIs

(note 1)

UL RLC SDU size

(bits)

(note 2)

Test data size

(bits)

(note 2)

1

DL_TFC1, DL_TFC7

UL_TFC1, DL_TFC7

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6

UL_TFC0, UL_TFC1,

UL_TFC2,

UL_TFC3,

UL_TFC6,

UL_TFC7

RB5: 39

RB6: 103

RB7: 60

RB8: 640

RB5: 39

RB6: No data

RB7: No data

RB8: No data

2

DL_TFC2, DL_TFC8

UL_TFC2, DL_TFC8

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6

UL_TFC0, UL_TFC1,

UL_TFC2,

UL_TFC3,

UL_TFC6,

UL_TFC8

RB5: 81

RB6: 103

RB7: 60

RB8: 640

RB5: 81

RB6: 103

RB7: 60

RB8: No data

3

DL_TFC3, DL_TFC9

UL_TFC3, DL_TFC9

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6

UL_TFC0, UL_TFC1,

UL_TFC2,

UL_TFC3,

UL_TFC6,

UL_TFC9

RB5: 39

RB6: 103

RB7: 60

RB8: 640

RB5: No data

RB6: No data

RB7: No data

RB8: 2×640

4

DL_TFC4, DL_TFC10

UL_TFC4, UL_TFC10

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6

UL_TFC0, UL_TFC1, UL_TFC2,

UL_TFC3, UL_TFC4,

UL_TFC6,

UL_TFC7, UL_TFC9, UL_TFC10

RB5: 39

RB6: 103

RB7: 60

RB8: 640

RB5: 39

RB6: No data

RB7: No data

RB8: 2×640

5

DL_TFC5, DL_TFC11

UL_TFC5, UL_TFC11

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6

UL_TFC0, UL_TFC1,

UL_TFC2, UL_TFC3, UL_TFC5, UL_TFC6,

UL_TFC8, UL_TFC9, UL_TFC11

RB5: 81

RB6: 103

RB7: 60

RB8: 640

RB5: 81

RB6: 103

RB7: 60

RB8: 2×640

NOTE 1: UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3 and UL_TFC6 are part of minimum set of TFCIs.

NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs.

14.2.49.1.4 Test requirements

See 14.1.2 for definition of step 10 and step 15.

1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.

2. At step 15a and step 15b the UE transmitted transport format shall be within the set of restricted TFCIs as specified for the actual sub-test.

3. At step 15a and step 15b the UE shall return

– for sub-test 1: RLC SDUs on RB5 having the same content as sent by the SS; and no data shall be received on RB6, RB7 and RB8.

– for sub-test 2: RLC SDUs on RB5, RB6 and RB7 having the same content as sent by the SS; and no data shall be received on RB8.

– for sub-test 3: RLC SDUs on RB8 having the same content as sent by the SS; and no data shall be received on RB5, RB6 and RB7.

– for sub-test 4: RLC SDUs on RB5 and RB8 having the same content as sent by the SS; and no data shall be received on RB6 and RB7.

– for sub-test 5: RLC SDUs on RB5, RB6, RB7 and RB8 having the same content as sent by the SS.

4. At step 15b the UE shall send at least one MEASUREMENT REPORT message.

14.2.49.2 Conversational / speech / UL:12.2 DL:12.2 kbps / CS RAB + Conversational / unknown / UL:64 DL:64 kbps / CS RAB / 40 ms TTI

14.2.49.2.1 Conformance requirement

See 14.2.4.1.

14.2.49.2.2 Test purpose

Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.10.2.4.1.49 for the 40 ms TTI case.

14.2.49.2.3 Method of test

Initial Conditions

The following RLC Info parameter values shall be set by the SS for the Conversational / unknown / UL:64 DL:64 kbps / CS RAB (RB8):

Uplink RLC

TM RLC

Segmentation indication

FALSE

Transmission RLC discard

CHOICE SDU Discard Mode

Timer based no explicit

Timer_discard

100ms

Downlink RLC

TM RLC

Segmentation indication

FALSE

NOTE: Timer based discard without explicit signalling is used in uplink to secure that the UE will be able to return data for the case when the UE test loop function will not deliver all the SDUs in one and the same TTI .

See 14.1.2 for test procedure.

Uplink TFS:

TFI

RB5

(RAB subflow #1)

RB6

(RAB subflow #2)

RB7

(RAB subflow #3)

RB8

(64 kbps)

DCCH

TFS

TF0, bits

0x81

0x103

0x60

0x640

0x148

TF1, bits

1×39

1×103

1×60

4×640

1×148

TF2, bits

1×81

N/A

N/A

N/A

N/A

Uplink TFCS:

TFCI

(RB5, RB6, RB7, RB8, DCCH)

UL_TFC0

(TF0, TF0, TF0, TF0, TF0)

UL_TFC1

(TF1, TF0, TF0, TF0, TF0)

UL_TFC2

(TF2, TF1, TF1, TF0, TF0)

UL_TFC3

(TF0, TF0, TF0, TF1, TF0)

UL_TFC4

(TF1, TF0, TF0, TF1, TF0)

UL_TFC5

(TF2, TF1, TF1, TF1, TF0)

UL_TFC6

(TF0, TF0, TF0, TF0, TF1)

UL_TFC7

(TF1, TF0, TF0, TF0, TF1)

UL_TFC8

(TF2, TF1, TF1, TF0, TF1)

UL_TFC9

(TF0, TF0, TF0, TF1, TF1)

UL_TFC10

(TF1, TF0, TF0, TF1, TF1)

UL_TFC11

(TF2, TF1, TF1, TF1, TF1)

Downlink TFS:

RB5

(RAB subflow #1)

RB6

(RAB subflow #2)

RB7

(RAB subflow #3)

RB8

(64 kbps)

DCCH

TFS

TF0, bits

1×0

0x103

0x60

0x640

0x148

TF1, bits

1×39

1×103

1×60

4×640

1×148

TF2, bits

1×81

N/A

N/A

N/A

N/A

Downlink TFCS:

TFCI

(RB5, RB6, RB7, RB8, DCCH)

DL_TFC0

(TF0, TF0, TF0, TF0, TF0)

DL_TFC1

(TF1, TF0, TF0, TF0, TF0)

DL_TFC2

(TF2, TF1, TF1, TF0, TF0)

DL_TFC3

(TF0, TF0, TF0, TF1, TF0)

DL_TFC4

(TF1, TF0, TF0, TF1, TF0)

DL_TFC5

(TF2, TF1, TF1, TF1, TF0)

DL_TFC6

(TF0, TF0, TF0, TF0, TF1)

DL_TFC7

(TF1, TF0, TF0, TF0, TF1)

DL_TFC8

(TF2, TF1, TF1, TF0, TF1)

DL_TFC9

(TF0, TF0, TF0, TF1, TF1)

DL_TFC10

(TF1, TF0, TF0, TF1, TF1)

DL_TFC11

(TF2, TF1, TF1, TF1, TF1)

Sub-tests:

Sub-test

Downlink TFCS

Under

Test

Uplink TFCS

Under test

Implicitly tested

Restricted UL TFCIs

(note1)

UL RLC SDU size

(bits)

(note2)

Test data size

(bits)

(note2)

1

DL_TFC1,DL_TFC7

UL_TFC1,DL_TFC7

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6

UL_TFC0, UL_TFC1,

UL_TFC2,

UL_TFC3,

UL_TFC6,

UL_TFC7

RB5: 39

RB6: 103

RB7: 60

RB8: 640

RB5: 39

RB6: No data

RB7: No data

RB8: No data

2

DL_TFC2,DL_TFC8

UL_TFC2,DL_TFC8

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6

UL_TFC0,

UL_TFC1, UL_TFC2,

UL_TFC3, UL_TFC6,

UL_TFC8

RB5: 81

RB6: 103

RB7: 60

RB8: 640

RB5: 81

RB6: 103

RB7: 60

RB8: No data

3

DL_TFC3,DL_TFC9

UL_TFC3,DL_TFC9

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6

UL_TFC0,

UL_TFC1,

UL_TFC2, UL_TFC3,

UL_TFC6,

UL_TFC9

RB5: 39

RB6: 103

RB7: 60

RB8: 640

RB5: No data

RB6: No data

RB7: No data

RB8: 4×640

4

DL_TFC4,DL_TFC10

UL_TFC4,DL_TFC10

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6

UL_TFC0, UL_TFC1,

UL_TFC2, UL_TFC3, UL_TFC4,

UL_TFC6,

UL_TFC7, UL_TFC9,

UL_TFC10

RB5: 39

RB6: 103

RB7: 60

RB8: 640

RB5: 39

RB6: No data

RB7: No data

RB8: 4×640

5

DL_TFC5,DL_TFC11

UL_TFC5,DL_TFC11

DL_TFC0, DL_TFC6, UL_TFC0, UL_TFC6

UL_TFC0,

UL_TFC1, UL_TFC2, UL_TFC3, UL_TFC5, UL_TFC6,

UL_TFC8, UL_TFC9,

UL_TFC11

RB5: 81

RB6: 103

RB7: 60

RB8: 640

RB5: 81

RB6: 103

RB7: 60

RB8: 4×640

NOTE1: UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3 and UL_TFC6 are part of minimum set of TFCIs.

NOTE2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs.
As the TTI for RB8 is the same for both downlink and uplink then UL RLC SDU size has been set to achieve UE to return one SDU per TTI, i.e. the UL RLC SDU size has been set equal to the uplink TB size.

14.2.49.2.4 Test requirements

See 14.1.2 for definition of step 10 and step 15.

1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.

2. At step 15a and 15b the UE transmitted transport format shall be within the set of restricted TFCIs as specified for the actual subtest.

3. At step 15 the UE shall return

– for sub-test 1: RLC SDUs on RB5 having the same content as sent by SS; and no data shall be received on RB6, RB7 and RB8.

– for sub-test 2: RLC SDUs on RB5, RB6 and RB7 having the same content as sent by SS; and no data shall be received on RB8.

– for sub-test 3: four RLC SDUs on RB8 having the same content as sent by SS; and no data shall be received on RB5, RB6 and RB7.

– for sub-test 4: RLC SDUs on RB5 and four RLC SDUs on RB8 having the same content as sent by SS; and no data shall be received on RB6 and RB7.

– for sub-test 5: RLC SDUs on RB5, RB6 and RB7; and four RLC SDUs on RB8 having the same content as sent by SS.

4. At step 15b the UE shall send at least one MEASUREMENT REPORT message.