14.2.25 Interactive or background / UL:32 DL: 64 kbps / PS RAB + UL:3.4 DL:3.4 kbps SRBs for DCCH
34.123-13GPPPart 1: Protocol conformance specificationRelease 15TSUser Equipment (UE) conformance specification
14.2.25.1 Interactive or background / UL:32 DL: 64 kbps / PS RAB / (TC, 10 ms TTI)
14.2.25.1.1 Conformance requirement
See 14.2.4.1.
14.2.25.1.2 Test purpose
Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.10.2.4.1.25 for the uplink turbo channel coding and 10 ms TTI case.
14.2.25.1.3 Method of test
Uplink TFS:
TFI |
RB5 (32 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x336 |
0x148 |
TF1, bits |
1×336 |
1×148 |
Uplink TFCS:
TFCI |
(RB5, DCCH) |
UL_TFC0 |
(TF0, TF0) |
UL_TFC1 |
(TF1, TF0) |
UL_TFC2 |
(TF0, TF1) |
UL_TFC3 |
(TF1, TF1) |
Downlink TFS:
TFI |
RB5 (64 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x336 |
0x148 |
TF1, bits |
1×336 |
1×148 |
|
TF2, bits |
2×336 |
N/A |
|
TF3, bits |
3×336 |
N/A |
|
TF4, bits |
4×336 |
N/A |
Downlink TFCS:
TFCI |
(RB5, DCCH) |
DL_TFC0 |
(TF0, TF0) |
DL_TFC1 |
(TF1, TF0) |
DL_TFC2 |
(TF2, TF0) |
DL_TFC3 |
(TF3, TF0) |
DL_TFC4 |
(TF4, TF0) |
DL_TFC5 |
(TF0, TF1) |
DL_TFC6 |
(TF1, TF1) |
DL_TFC7 |
(TF2, TF1) |
DL_TFC8 |
(TF3, TF1) |
DL_TFC9 |
(TF4, TF1) |
Sub-tests:
Sub-test |
Downlink TFCS Under test |
Uplink TFCS Under test |
Implicitly tested |
Restricted UL TFCIs (note 1) |
UL RLC SDU size (bits) (note 2) |
Test data size (bits) (note 2) |
1 |
DL_TFC1 |
UL_TFC1 |
DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC2 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3 |
RB5: 312 |
RB5: 312 |
2 |
DL_TFC2 |
UL_TFC1 |
DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC2 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3 |
RB5: 632 |
RB5: 632 |
3 |
DL_TFC3 |
UL_TFC1 |
DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC2 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3 |
RB5: 952 |
RB5: 952 |
4 |
DL_TFC4 |
UL_TFC1 |
DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC2 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3 |
RB5: 1272 |
RB5: 1272 |
NOTE 1: UL_TFC0, UL_TFC1 and UL_TFC2 are part of minimum set of TFCIs. NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs. |
See 14.1.1 for test procedure.
14.2.25.1.4 Test requirements
See 14.1.1 for definition of step 10 and step 15.
1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.
2. At step 15 the UE transmitted transport format shall be
– for sub-test 1 to 4: RB5/TF1 (1×336).
3. At step 15 the UE shall return
– for sub-test 1 to 4: an RLC SDU on RB5 having the same content as the DL RLC SDU sent by the SS.
14.2.25.2 Interactive or background / UL:32 DL: 64 kbps / PS RAB / (TC, 20 ms TTI)
14.2.25.2.1 Conformance requirement
See 14.2.4.1.
14.2.25.2.2 Test purpose
Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.10.2.4.1.25 for the uplink turbo channel coding and 20 ms TTI case.
14.2.25.2.3 Method of test
Uplink TFS:
TFI |
RB5 (32 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x336 |
0x148 |
TF1, bits |
1×336 |
1×148 |
|
TF2, bits |
2×336 |
N/A |
Uplink TFCS:
TFCI |
(RB5, DCCH) |
UL_TFC0 |
(TF0, TF0) |
UL_TFC1 |
(TF1, TF0) |
UL_TFC2 |
(TF2, TF0) |
UL_TFC3 |
(TF0, TF1) |
UL_TFC4 |
(TF1, TF1) |
UL_TFC5 |
(TF2, TF1) |
Downlink TFS:
TFI |
RB5 (64 kbps) |
DCCH |
|
TFS |
TF0, bits |
0x336 |
0x148 |
TF1, bits |
1×336 |
1×148 |
|
TF2, bits |
2×336 |
N/A |
|
TF3, bits |
3×336 |
N/A |
|
TF4, bits |
4×336 |
N/A |
Downlink TFCS:
TFCI |
(RB5, DCCH) |
DL_TFC0 |
(TF0, TF0) |
DL_TFC1 |
(TF1, TF0) |
DL_TFC2 |
(TF2, TF0) |
DL_TFC3 |
(TF3, TF0) |
DL_TFC4 |
(TF4, TF0) |
DL_TFC5 |
(TF0, TF1) |
DL_TFC6 |
(TF1, TF1) |
DL_TFC7 |
(TF2, TF1) |
DL_TFC8 |
(TF3, TF1) |
DL_TFC9 |
(TF4, TF1) |
Sub-tests:
Sub-test |
Downlink TFCS Under test |
Uplink TFCS Under test |
Implicitly tested |
Restricted UL TFCIs (note 1) |
UL RLC SDU size (bits) (note 2) |
Test data size (bits) (note 2) |
1 |
DL_TFC1 |
UL_TFC1 |
DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC3 |
UL_TFC0, UL_TFC1, UL_TFC3, UL_TFC4 |
RB5: 312 |
RB5: 312 |
2 |
DL_TFC2 |
UL_TFC2 |
DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC3 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3, UL_TFC5 |
RB5: 632 |
RB5: 632 |
3 |
DL_TFC3 |
UL_TFC1 |
DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC3 |
UL_TFC0, UL_TFC1, UL_TFC3, UL_TFC4 |
RB5: 952 |
RB5: 952 |
4 |
DL_TFC4 |
UL_TFC2 |
DL_TFC0, DL_TFC5, UL_TFC0, UL_TFC3 |
UL_TFC0, UL_TFC1, UL_TFC2, UL_TFC3, UL_TFC5 |
RB5: 1272 |
RB5: 1272 |
NOTE 1: UL_TFC0, UL_TFC1 and UL_TFC3 are part of minimum set of TFCIs. NOTE 2: See TS 34.109 [10] clause 5.3.2.6.2 for details regarding loopback of RLC SDUs. |
See 14.1.1 for test procedure.
14.2.25.2.4 Test requirements
See 14.1.1 for definition of step 10 and step 15.
1. At step 10 the UE shall send RADIO BEARER SETUP COMPLETE.
2. At step 15 the UE transmitted transport format shall be
– for sub-test 1: RB5/TF1 (1×336).
– for sub-test 2: RB5/TF2 (2×336).
– for sub-test 3: RB5/TF1 (1×336).
– for sub-test 4: RB5/TF2 (2×336).
3. At step 15 the UE shall return
– for sub-test 1 to 4: an RLC SDU on RB5 having the same content as the DL RLC SDU sent by the SS.
14.2.25.3 Interactive or background / UL:32 DL:64 kbps / PS RAB / (CC, 10 ms TTI)
Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.10.2.4.1.25 for the uplink convolutional channel coding and 10 ms TTI case.
See test case 14.2.25.1 for test procedure and test requirement.
14.2.25.4 Interactive or background / UL:32 DL:64 kbps / PS RAB / (CC, 20 ms TTI)
Test to verify establishment and data transfer of reference radio bearer configuration as specified in TS 34.108, clause 6.10.2.4.1.25 for the uplink convolutional channel coding and 20 ms TTI case.
See test case 14.2.25.2 for test procedure and test requirement.