12.8 GMM READY timer handling

34.123-13GPPPart 1: Protocol conformance specificationRelease 15TSUser Equipment (UE) conformance specification

12.8.1 Definition

12.8.2 Conformance requirement

If a READY timer value is received by an UE capable of both UMTS and GSM in the ATTACH ACCEPT or the ROUTING AREA UPDATE ACCEPT messages, then the received value shall be stored by the UE in order to be used at an intersystem change from UMTS to GSM.

Reference

3GPP TS 24.008 clause 4.7.2.1

12.8.3 Test purpose

To verify that READY timer value received in UTRA can be used in GSM.

12.8.4 Method of test

12.8.4.1 Test procedure

Initial condition

System Simulator:

Two cells (not simultaneously activated), cell A (UTRAN) in MCC1/MNC1/LAC1/RAC1 (RAI-1), cell B (GSM) in MCC1/MNC1/LAC1/RAC2 (RAI-4).

Parameter

Unit

Cell B

(GSM)

Qsearch_I (TDD)

dBm

15 (never)

Cell B is in neighbour cell list of cell A.
Both cells are operating in network operation mode II.
The SIB1 IE "CN domain specific NAS system information", for the CS Domain, is set to value "00 00" (T3212 value is set to 0 and ATT flag is set to FALSE) in cell A (UTRAN).
The value of ATT flag in SIB3 IE “Control Channel Description” is set to value “0” in cell B (GSM).

In SIB3 and SIB4 the IE “SsearchRAT”, is set to value “20dB” in cell A (UTRAN).

User Equipment:

The UE has a valid IMSI.

The UE has been registered in the CS domain.

Related ICS/IXIT statements

UE supports both GSM/GPRS and UTRAN Radio Access Technologies Yes/No
UE operation mode A Yes/No
Switch off on button Yes/No
Automatic PS attach procedure at switch on or power on Yes/No

Test procedure

An attach is performed.

T3314; set to 60 seconds

Expected Sequence

Step

Direction

Message

Comments

UE

SS

The following messages are sent and shall be received on cell A.

1

SS

Set the cell type of cell A to the "Serving cell".

Cell B is switched off.

(see note)

2

UE

The UE is set in UE operation mode A (see ICS). If UE operation mode A not supported set the UE in operation mode C.

The UE is powered up or switched on and initiates an attach (see ICS).

2a

SS

SS checks that the IE "Establishment cause" in the received RRC CONNECTION REQUEST message is set to "Registration".

3

->

ATTACH REQUEST

Attach type = ‘GPRS attach’

Mobile identity = IMSI

3a

<-

AUTHENTICATION AND CIPHERING REQUEST

3b

->

AUTHENTICATION AND CIPHERING RESPONSE

3c

SS

The SS starts integrity protection.

4

<-

ATTACH ACCEPT

Attach result = ‘GPRS only attached’

Allocated P-TMSI = P-TMSI-2

P-TMSI Signature = P-TMSI-2 signature

Routing area identity = RAI-1

T3314 = 60 seconds

T3312=6 minutes

5

->

ATTACH COMPLETE

5a

SS

The SS releases the RRC connection.

6

SS

Set the cell type of cell A to the "Suitable neighbour cell". Set the cell type of cell B to the "Serving cell".

7

UE

UE establish cell reselection to GSM system

The following messages are received on Cell B (GERAN)

8a

UE

Registration on CS

Optional step. See TS 34.108

Location Update Procedure may be initiated from the UE.

8

->

ROUTING AREA UPDATE REQUEST

Update type = ‘RA updating’

Old P-TMSI signature=P-TMSI-2 signature

Old Routing area identity = RAI-1

9

<-

ROUTING AREA UPDATE ACCEPT

Update result = ‘RA updated’

Allocated P-TMSI = P-TMSI-1

P-TMSI Signature = P-TMSI-1 signature

Routing area identity = RAI-4

10

->

ROUTING AREA UPDATE COMPLETE

11

SS

The SS verifies that the time between the end of Step 10 and the periodic RA updating is Ready

Timer Period (T3314) + Periodic Routing Area

Updating timer (T3312) (+/- 10%)

12

->

ROUTING AREA UPDATE REQUEST

Update type = ‘Periodic updating’

Old P-TMSI signature=P-TMSI-1 signature
Old Routing area identity = RAI-4

13

<-

ROUTING AREA UPDATE ACCEPT

Update type = ‘RA updated’

14

UE

UE is switched off or power is removed (see ICS)

15

->

DETACH REQUEST

Message not sent if power is removed.

Detach type = ‘power switched off, GPRS detach’

NOTE: The definitions for "Non-Suitable cell" and "Serving cell" are specified in TS34.108 clause 6.1 in the relevant to the RAT of the cells "Reference Radio Conditions" subclauses.

Specific message contents

None.

12.8.5 Test requirements

At step4, when the UE receives the ATTACH ACCEPT or the ROUTING AREA UPDATE ACCEPT messages, UE shall:

– store the received READY timer value.

At step12, UE shall establish periodic Routing Area Update after Timer Period (T3314) + Periodic Routing Area

Updating timer (T3312) (+/- 10%).