9.2.1 Default Message Contents for RF (FDD)

34.1083GPPCommon test environments for User Equipment (UE)Conformance testingRelease 15TS

Contents of Activate RB Test Mode message

Information Element

Value/remark

Protocol discriminator

F (Length 1/2)

Skip indicator

0 (Length 1/2)

Message Type

44h

Contents of Close UE Test Loop message (UE test loop mode 1 without Dummy DCCH transmission)

Information Element

Value/remark

Protocol discriminator

F (Length 1/2)

Skip indicator

0 (Length 1/2)

Message Type

40h

UE test loop mode

00h

UE test loop mode 1 LB setup

03h 00h F4h 0Ah

Contents of Close UE Test Loop message (UE test loop mode 2 without Dummy DCCH transmission)

Information Element

Value/remark

Protocol discriminator

F (Length 1/2)

Skip indicator

0 (Length 1/2)

Message Type

40h

UE test loop mode

01h

Contents of Open UE Test Loop message

Information Element

Value/remark

Protocol discriminator

F (Length 1/2)

Skip indicator

0 (Length 1/2)

Message Type

42h

Contents of MBMS COMMON P-T-M RB INFORMATION message: UM

Information Element

Value/remark

Version

Message type

Rel-6

RB information list

One entry in the list

Rel-6

– RB identity

14

Rel-6

– PDCP info

– Support for lossless SRNS relocation

Not Present

– PDCP PDU header

Absent

– Header compression information

Not Present

– RLC info

– DL UM RLC LI size

Selected with DL UM RLC data size

– DL Duplication Avoidance and Reordering info

Not Present

TrCh information for each TrCh

One entry in the list

Rel-6

– Transport channel identity

17

Rel-6

– TFS

– CHOICE Transport channel type

Common transport channels

– Dynamic Transport format information

– RLC Size

Reference to TS34.121 [2] Annex C.12 DL reference parameters or as specified within test case in TS34.121 [2].

– Number of TBs List

(This IE is repeated for TFI number.)

– Transmission Time Interval

Not Present

– Number of Transport blocks

Reference to TS34.121 [2] Annex C.12 DL reference parameters or as specified within test case in TS34.121 [2].

– CHOICE Logical channel list

All

– Semi-static Transport Format information

– Transmission time interval

Reference to TS34.121 [2] Annex C.12 DL reference parameters or as specified within test case in TS34.121 [2].

– Type of channel coding

Reference to TS34.121 [2] Annex C.12 DL reference parameters or as specified within test case in TS34.121 [2].

– Coding Rate

Reference to TS34.121 [2] Annex C.12 DL reference parameters or as specified within test case in TS34.121 [2].

– Rate matching attribute

Reference to TS34.121 [2] Annex C.12 DL reference parameters or as specified within test case in TS34.121 [2]

– CRC size

Reference to TS34.121 [2] Annex C.12 DL reference parameters or as specified within test case in TS34.121 [2].

TrCh information for each CCTrCh

One entry in the list

Rel-6

– CCTrCH identity

1

Rel-6

– TFCS

– CHOICE TFCI signalling

Normal

– TFCI Field 1 information

– CHOICE TFCS representation

Complete reconfiguration

– TFCS complete reconfiguration information

– CHOICE CTFC Size

Number of bits used must be enough to cover all combinations of CTFC from TS34.121 [2] Annex C.12 parameter set or as specified within test case in TS34.121 [2].

– CTFC information

This IE is repeated for number of CTFCs from TS34.121 [2] Annex C.12 parameter set or as specified within test case in TS34.121 [2].

– CTFC

Reference to TS34.121 [2] Annex C.12 parameter set or as specified within test case in TS34.121 [2].

– Power offset information

Not Present

PhyCh information

One entry in list

Rel-6

– PhyCh identity

13

Rel-6

– Secondary CCPCH info MBMS

– CHOICE mode

FDD

– Secondary scrambling code

Not Present

– STTD indicator

FALSE

– Spreading factor

Reference to TS34.121 [2] Annex C.12 DL reference parameters.

– Code number

Reference to TS34.121 [2] Annex E.6.4 “Downlink physical channels code allocation for MBMS test cases”

– Timing Offset

Not Present

Absence of this IE is equivalent to default value 0.

Contents of PAGING TYPE 1 message: TM (CS)

Information Element

Value/remark

Message Type

Paging record list

-Paging record

– CHOICE Used paging identity

CN identity

– Paging cause

Terminating Streaming Call

– CN domain identity

CS domain

– CHOICE UE identity

– IMSI (GSM-MAP)

Set to the same octet string as in the IMSI stored in the USIM card

BCCH modification info

Not Present

Contents of PAGING TYPE 1 message: TM (PS)

Information Element

Value/remark

Message Type

Paging record list

-Paging record

– CHOICE Used paging identity

CN identity

– Paging cause

Terminating Interactive Call

– CN domain identity

PS domain

– CHOICE UE identity

– IMSI (GSM-MAP)

Set to the same octet string as in the IMSI stored in the USIM card

BCCH modification info

Not Present

Contents of PAGING TYPE 2 message: TM (PS)

Information Element

Value/remark

Message Type

RRC transaction identifier

Arbitrarily selects one integer between 0 to 3

Integrity check info

– message authentication code

SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I.

– RRC message sequence number

SS provides the value of this IE, from its internal counter.

– Paging cause

Terminating Interactive Call

– CN domain identity

PS domain

– Paging record type identifier

TMSI(GSM-MAP)/P-TMSI

Contents of RADIO BEARER SETUP message: AM or UM (Test Loop Mode1)

Information Element

Condition

Value/remark

Version

Index

Message Type

A1, A3, A4, A5, A6, A7, A8, A9

RBST-001

RRC transaction identifier

Arbitrarily selects an integer between 0 and 3

RBST-002

Integrity check info

RBST-003

– message authentication code

SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I.

RBST-004

– RRC message sequence number

SS provides the value of this IE, from its internal counter.

RBST-005

Integrity protection mode info

Not Present

RBST-006

Ciphering mode info

Not Present

RBST-007

Activation time

(256+CFN-(CFN MOD 8 + 8))MOD 256

RBST-008

New U-RNTI

Not Present

RBST-009

New C-RNTI

Not Present

RBST-010

New DSCH-RNTI

Not Present

R99 and Rel-4 only

RBST-011

New H-RNTI

Not Present

Rel-5

RBST-012

New Primary E-RNTI

Not Present

Rel-6

RBST-013

New Secondary E-RNTI

Not Present

Rel-6

RBST-014

RRC State indicator

CELL_DCH

RBST-015

UTRAN DRX cycle length coefficient

Not Present

RBST-016

CN information info

Not Present

RBST-017

URA identity

Not Present

RBST-018

CHOICE specification mode

Complete specification

Rel-6

RBST-019

– Signalling RB information to setup

Not Present

RBST-020

– RAB information for setup list

A1, A3, A4, A5

RBST-021

– RAB information for setup

RBST-022

– RAB info

RBST-023

– RAB identity

0000 0001B

The first/ leftmost bit of the bit string contains the most significant bit of the RAB identity.

RBST-024

– CN domain identity

CS domain

RBST-025

– NAS Synchronization Indicator

Not Present

RBST-026

– Re-establishment timer

UseT314

RBST-027

RBST-028

– RB information to setup list

RBST-029

– RB information to setup

RBST-030

– RAB information for setup list

A6, A7, A8, A9

RBST-031

– RAB information for setup

RBST-032

– RAB info

RBST-033

– RAB identity

0000 0101B

The first/ leftmost bit of the bit string contains the most significant bit of the RAB identity.

RBST-034

– CN domain identity

PS domain

RBST-035

– NAS Synchronization Indicator

Not Present

RBST-036

– Re-establishment timer

UseT315

RBST-037

RBST-038

– RB information to setup list

RBST-039

– RB information to setup

RBST-040

– RB identity

A1

10

RBST-041

– PDCP info

Not Present

RBST-042

– CHOICE RLC info type

RLC info

RBST-043

– CHOICE Uplink RLC mode

TM RLC

RBST-044

– Transmission RLC discard

Not Present

RBST-045

– Segmentation indication

FALSE

RBST-046

– CHOICE Downlink RLC mode

TM RLC

RBST-047

– Segmentation indication

FALSE

RBST-048

– One sided RLC re-establishment

FALSE

Rel-5

RBST-049

– RB mapping info

RBST-050

– Information for each multiplexing option

RBST-051

– RLC logical channel mapping indicator

Not Present

RBST-052

– Number of uplink RLC logical channels

1

RBST-053

– Uplink transport channel type

DCH

RBST-054

– UL Transport channel identity

1

RBST-055

– Logical channel identity

Not Present

RBST-056

– CHOICE RLC size list

Configured

RBST-057

– MAC logical channel priority

7

RBST-058

– Downlink RLC logical channel info

RBST-059

– Number of downlink RLC logical channels

1

RBST-060

– Downlink transport channel type

DCH

RBST-061

– DL DCH Transport channel identity

6

RBST-062

– DL DSCH Transport channel identity

Not Present

RBST-063

– Logical channel identity

Not Present

RBST-064

– RB identity

A3, A4, A5

10

RBST-065

– PDCP info

Not Present

RBST-066

– CHOICE RLC info type

RLC info

RBST-067

– CHOICE Uplink RLC mode

AM RLC

RBST-068

– Transmission RLC discard

RBST-069

– CHOICE SDU discard mode

No Discard

RBST-070

– MAX_DAT

15

RBST-071

– Transmission window size

Selected with Total RLC AM Buffer Size

RBST-072

– Timer_RST

500

RBST-073

– Max_RST

4

RBST-074

– Polling info

RBST-075

– Timer_poll_prohibit

400

RBST-076

– Timer_poll

400

RBST-077

– Poll_PDU

Not Present

RBST-078

– Poll_SDU

1

RBST-079

– Last transmission PDU poll

TRUE

RBST-080

– Last retransmission PDU poll

TRUE

RBST-081

– Poll_Windows

99

RBST-082

– Timer_poll_periodic

Not Present

RBST-083

– CHOICE Downlink RLC mode

AM RLC

RBST-084

– DL RLC PDU size

A3

1280 bits

Rel-5

RBST-085

– DL RLC PDU size

A4

2880 bits

Rel-5

RBST-086

– DL RLC PDU size

A5

3840 bits

Rel-5

RBST-087

– In-sequence delivery

A3, A4, A5

TRUE

RBST-088

– Receiving window size

Selected with Total RLC AM Buffer Size

RBST-089

– Downlink RLC status info

RBST-090

– Timer_status_prohibit

330

RBST-091

– Timer_EPC

Not Present

RBST-092

– Missing PDU indicator

TRUE

RBST-093

– Timer_STATUS_periodic

Not Present

RBST-094

– One sided RLC re-establishment

FALSE

Rel-5

RBST-095

– RB mapping info

RBST-096

– Information for each multiplexing option

RBST-097

– RLC logical channel mapping indicator

Not Present

RBST-098

– Number of uplink RLC logical channels

1

RBST-099

– Uplink transport channel type

DCH

RBST-100

– UL Transport channel identity

1

RBST-101

– Logical channel identity

Not Present

RBST-102

– CHOICE RLC size list

Configured

RBST-103

– MAC logical channel priority

7

RBST-104

– Downlink RLC logical channel info

RBST-105

– Number of downlink RLC logical channels

1

RBST-106

– Downlink transport channel type

DCH

RBST-107

– DL DCH Transport channel identity

6

RBST-108

– DL DSCH Transport channel identity

Not Present

RBST-109

– Logical channel identity

Not Present

RBST-110

– RB identity

A6, A7, A8, A9

20

RBST-111

– PDCP info

Not present

RBST-112

– CHOICE RLC info type

RLC info

RBST-113

– CHOICE Uplink RLC mode

AM RLC

RBST-114

– Transmission RLC discard

RBST-115

– CHOICE SDU discard mode

No Discard

RBST-116

– MAX_DAT

15

RBST-117

– Transmission window size

Selected with Total RLC AM Buffer Size

RBST-118

– Timer_RST

500

RBST-119

– Max_RST

4

RBST-120

– Polling info

RBST-121

– Timer_poll_prohibit

400

RBST-122

– Timer_poll

400

RBST-123

– Poll_PDU

Not Present

RBST-124

– Poll_SDU

1

RBST-125

– Last transmission PDU poll

TRUE

RBST-126

– Last retransmission PDU poll

TRUE

RBST-127

– Poll_Windows

99

RBST-128

– Timer_poll_periodic

Not Present

RBST-129

– CHOICE Downlink RLC mode

AM RLC

RBST-130

– DL RLC PDU size

A6

1280 bits

Rel-5

RBST-131

– DL RLC PDU size

A7

2880 bits

Rel-5

RBST-132

– DL RLC PDU size

A8

3840 bits

Rel-5

RBST-133

– DL RLC PDU size

A9

336 bits

Rel-5

RBST-134

– In-sequence delivery

A6, A7, A8, A9

TRUE

RBST-135

– Receiving window size

Selected with Total RLC AM Buffer Size

RBST-136

– Downlink RLC status info

RBST-137

– Timer_status_prohibit

330

RBST-138

– Timer_EPC

Not Present

RBST-139

– Missing PDU indicator

TRUE

RBST-140

– Timer_STATUS_periodic

Not Present

RBST-141

– One sided RLC re-establishment

FALSE

Rel-5

RBST-142

– RB mapping info

RBST-143

– Information for each multiplexing option

2 RBMuxOptions

RBST-144

– RLC logical channel mapping indicator

Not Present

RBST-145

– Number of uplink RLC logical channels

1

RBST-146

– Uplink transport channel type

DCH

RBST-147

– UL Transport channel identity

1

RBST-148

– Logical channel identity

Not Present

RBST-149

– CHOICE RLC size list

Configured

RBST-150

– MAC logical channel priority

8

RBST-151

– Downlink RLC logical channel info

RBST-152

– Number of downlink RLC logical channels

1

RBST-153

– Downlink transport channel type

DCH

RBST-154

– DL DCH Transport channel identity

6

RBST-155

– DL DSCH Transport channel identity

Not Present

RBST-156

– Logical channel identity

Not Present

RBST-157

– RLC logical channel mapping indicator

Not Present

RBST-158

– Number of uplink RLC logical channels

1

RBST-159

– Uplink transport channel type

RACH

RBST-160

– UL Transport channel identity

Not Present

RBST-161

– Logical channel identity

7

RBST-162

– CHOICE RLC size list

Explicit list

RBST-163

– RLC size index

Reference to clause 6 Parameter Set

RBST-164

– MAC logical channel priority

8

RBST-165

– Downlink RLC logical channel info

RBST-166

– Number of downlink RLC logical channels

1

RBST-167

– Downlink transport channel type

FACH

RBST-168

– DL DCH Transport channel identity

Not Present

RBST-169

– DL DSCH Transport channel identity

Not Present

RBST-170

– Logical channel identity

7

RBST-171

RB information to reconfigure list

A1, A3, A4, A5, A6, A7, A8, A9

Not Present

Rel-6

RBST-172

RB information to be affected list

Not Present

RBST-173

Downlink counter synchronization info

Not Present

RBST-174

PDCP ROHC target mode

Not Present

Rel-5

RBST-175

UL Transport channel information for all transport channels

RBST-176

– PRACH TFCS

Not Present

RBST-177

– CHOICE mode

FDD

RBST-178

– TFC subset

Not Present

RBST-179

– UL DCH TFCS

RBST-180

– CHOICE TFCI signalling

Normal

RBST-181

– TFCI Field 1 information

RBST-182

– CHOICE TFCS representation

Complete reconfiguration

RBST-183

– TFCS complete reconfigure information

RBST-184

– CHOICE CTFC Size

2 bit CTFC

RBST-185

– CTFC information

4 TFCs

RBST-186

– 2bit CTFC

0

RBST-187

-Power offset Information

RBST-188

– CHOICE Gain Factors

Computed Gain Factors

RBST-189

– Reference TFC ID

0

RBST-190

– CHOICE mode

FDD

RBST-191

– Power offset Pp-m

Not Present

RBST-192

– 2bit CTFC

2

RBST-193

– Power offset Information

RBST-194

– CHOICE Gain Factors

Computed Gain Factors

RBST-195

– Reference TFC ID

0

RBST-196

– CHOICE mode

FDD

RBST-197

– Power offset Pp-m

Not Present

RBST-198

– 2bit CTFC

1

RBST-199

– Power offset Information

RBST-200

– CHOICE Gain Factors

Computed Gain Factors

RBST-201

– Reference TFC ID

0

RBST-202

– CHOICE mode

FDD

RBST-203

– Power offset Pp-m

Not Present

RBST-204

– 2bit CTFC

3

RBST-205

– Power offset Information

RBST-206

– CHOICE Gain Factors

Signalled Gain Factors

RBST-207

– CHOICE mode

FDD

RBST-208

– Gain factor ßc

8

RBST-209

– Gain factor ßd

15

RBST-210

– Reference TFC ID

0

RBST-211

– CHOICE mode

FDD

RBST-212

– Power offset Pp-m

Not Present

RBST-213

Deleted UL TrCH information list

Not Present

RBST-214

Added or Reconfigured TrCH information list

A1

1

RBST-215

– Added or Reconfigured UL TrCH information

RBST-216

– Uplink transport channel type

DCH

RBST-217

– UL Transport channel identity

1

RBST-218

– TFS

RBST-219

– CHOICE Transport channel type

Dedicated transport channels

RBST-220

– Dynamic Transport Format Information

RBST-221

– RLC size

244 bits

RBST-222

– Number of TBs and TTI List

2

RBST-223

– Transmission Time Interval

Not Present

RBST-224

– Number of Transport blocks

0

RBST-225

– Transmission Time Interval

Not Present

RBST-226

– Number of Transport blocks

1

RBST-227

– CHOICE Logical channel List

ALL

RBST-228

– Semi-static Transport Format Information

RBST-229

– Transmission time interval

20

RBST-230

– Type of channel coding

Convolutional

RBST-231

– Coding Rate

1/3

RBST-232

– Rate matching attribute

256

RBST-233

– CRC size

16

RBST-234

Added or Reconfigured TrCH information list

A3, A4, A5, A6, A7, A8, A9

1

RBST-235

– Added or Reconfigured UL TrCH information

RBST-236

– Uplink transport channel type

DCH

RBST-237

– UL Transport channel identity

1

RBST-238

– TFS

RBST-239

– CHOICE Transport channel type

Dedicated transport channels

RBST-240

– Dynamic Transport Format Information

RBST-241

– RLC size

240 bits

RBST-242

– Number of TBs and TTI List

2

RBST-243

– Transmission Time Interval

Not Present

RBST-244

– Number of Transport blocks

0

RBST-245

– Transmission Time Interval

Not Present

RBST-246

– Number of Transport blocks

1

RBST-247

– CHOICE Logical channel List

ALL

RBST-248

– Semi-static Transport Format Information

RBST-249

– Transmission time interval

20

RBST-250

– Type of channel coding

Convolutional

RBST-251

– Coding Rate

1/3

RBST-252

– Rate matching attribute

256

RBST-253

– CRC size

16

RBST-254

CHOICE mode

A1, A3, A4, A5, A6, A7, A8

Not Present

RBST-255

DL Transport channel information common for all transport channel

RBST-256

– SCCPCH TFCS

Not Present

RBST-257

– CHOICE mode

FDD

RBST-258

– CHOICE DL parameters

Same as UL

RBST-259

Deleted DL TrCH information list

Not Present

RBST-260

CHOICE mode

A9

Not Present

RBST-261

DL Transport channel information common for all transport channel

RBST-262

– SCCPCH TFCS

Not Present

RBST-263

– CHOICE mode

FDD

RBST-264

– CHOICE DL parameters

DL DCH TFCS

RBST-265

– DL DCH TFCS

RBST-266

– CHOICE TFCI signalling

Normal

RBST-267

– TFCI Field 1 information

RBST-268

– CHOICE TFCS representation

Complete reconfiguration

RBST-269

– TFCS complete reconfigure information

RBST-270

– CHOICE CTFC Size

4 bit CTFC

RBST-271

– CTFC information

6 TFCs

RBST-272

– 4bit CTFC

0

RBST-273

– Power offset Information

RBST-274

– CHOICE Gain Factors

Computed Gain Factors

RBST-275

– Reference TFC ID

0

RBST-276

– CHOICE mode

FDD

RBST-277

– Power offset Pp-m

Not Present

RBST-278

– 4bit CTFC

3

RBST-279

– Power offset Information

RBST-280

– CHOICE Gain Factors

Computed Gain Factors

RBST-281

– Reference TFC ID

0

RBST-282

– CHOICE mode

FDD

RBST-283

– Power offset Pp-m

Not Present

RBST-284

– 4bit CTFC

1

RBST-285

– Power offset Information

RBST-286

– CHOICE Gain Factors

Computed Gain Factors

RBST-287

– Reference TFC ID

0

RBST-288

– CHOICE mode

FDD

RBST-289

– Power offset Pp-m

Not Present

RBST-290

– 4bit CTFC

4

RBST-291

– Power offset Information

RBST-292

– CHOICE Gain Factors

Computed Gain Factors

RBST-293

– Reference TFC ID

0

RBST-294

– CHOICE mode

FDD

RBST-295

– Power offset Pp-m

Not Present

RBST-296

– 4bit CTFC

2

RBST-297

– Power offset Information

RBST-298

– CHOICE Gain Factors

Computed Gain Factors

RBST-299

– Reference TFC ID

0

RBST-300

– CHOICE mode

FDD

RBST-301

– Power offset Pp-m

Not Present

RBST-302

– 4bit CTFC

5

RBST-303

– Power offset Information

RBST-304

– CHOICE Gain Factors

Signalled Gain Factors

RBST-305

– CHOICE mode

FDD

RBST-306

– Gain factor ßc

8

RBST-307

– Gain factor ßd

15

RBST-308

– Reference TFC ID

0

RBST-309

– CHOICE mode

FDD

RBST-310

– Power offset Pp-m

Not Present

RBST-311

Deleted DL TrCH information list

Not Present

RBST-312

Added or Reconfigured TrCH information list

A1

1

RBST-313

– Added or Reconfigured DL TrCH information

RBST-314

– Downlink transport channel type

DCH

RBST-315

– DL Transport channel identity

6

RBST-316

– CHOICE DL parameters

Same as UL

RBST-317

– Uplink transport channel type

DCH

RBST-318

– UL TrCH identity

1

RBST-319

– DCH quality target

RBST-320

– BLER Quality value

-20 (-2.0)

RBST-321

Added or Reconfigured TrCH information list

A3, A6

1

RBST-322

– Added or Reconfigured DL TrCH information

RBST-323

– Downlink transport channel type

DCH

RBST-324

– DL Transport channel identity

6

RBST-325

– CHOICE DL parameters

Explicit

RBST-326

– TFS

RBST-327

– CHOICE Transport channel type

Dedicated transport channels

RBST-328

– Dynamic transport format information

RBST-329

– RLC Size

1280 bits

RBST-330

– Number of TBs and TTI List

2

RBST-331

– Transmission Time Interval

Not Present

RBST-332

– Number of Transport blocks

0

RBST-333

– Transmission Time Interval

Not Present

RBST-334

– Number of Transport blocks

1

RBST-335

– CHOICE Logical channel list

ALL

RBST-336

– Semi-static Transport Format information

RBST-337

– Transmission time interval

20

RBST-338

– Type of channel coding

Turbo

RBST-339

– Rate matching attribute

256

RBST-340

– CRC size

16

RBST-341

– DCH quality target

RBST-342

– BLER Quality value

-20 (-2.0)

RBST-343

Added or Reconfigured TrCH information list

A4, A7

1

RBST-344

– Added or Reconfigured DL TrCH information

RBST-345

– Downlink transport channel type

DCH

RBST-346

– DL Transport channel identity

6

RBST-347

– CHOICE DL parameters

Explicit

RBST-348

– TFS

RBST-349

– CHOICE Transport channel type

Dedicated transport channels

RBST-350

– Dynamic transport format information

RBST-351

– RLC Size

2880 bits

RBST-352

– Number of TBs and TTI List

2

RBST-353

– Transmission Time Interval

Not Present

RBST-354

– Number of Transport blocks

0

RBST-355

– Transmission Time Interval

Not Present

RBST-356

– Number of Transport blocks

1

RBST-357

– CHOICE Logical channel list

ALL

RBST-358

– Semi-static Transport Format information

RBST-359

– Transmission time interval

20

RBST-360

– Type of channel coding

Turbo

RBST-361

– Rate matching attribute

256

RBST-362

– CRC size

16

RBST-363

– DCH quality target

RBST-364

– BLER Quality value

-20 (-2.0)

RBST-365

Added or Reconfigured TrCH information list

A5, A8

1

RBST-366

– Added or Reconfigured DL TrCH information

RBST-367

– Downlink transport channel type

DCH

RBST-368

– DL Transport channel identity

6

RBST-369

– CHOICE DL parameters

Explicit

RBST-370

– TFS

RBST-371

– CHOICE Transport channel type

Dedicated transport channels

RBST-372

– Dynamic transport format information

RBST-373

– RLC Size

3840 bits

RBST-374

– Number of TBs and TTI List

2

RBST-375

– Transmission Time Interval

Not Present

RBST-376

– Number of Transport blocks

0

RBST-377

– Transmission Time Interval

Not Present

RBST-378

– Number of Transport blocks

1

RBST-379

– CHOICE Logical channel list

ALL

RBST-380

– Semi-static Transport Format information

RBST-381

– Transmission time interval

10

RBST-382

– Type of channel coding

Turbo

RBST-383

– Rate matching attribute

256

RBST-384

– CRC size

16

RBST-385

– DCH quality target

RBST-386

– BLER Quality value

-20 (-2.0)

RBST-387

Added or Reconfigured TrCH information list

A9

1

RBST-388

– Added or Reconfigured DL TrCH information

RBST-389

– Downlink transport channel type

DCH

RBST-390

– DL Transport channel identity

6

RBST-391

– CHOICE DL parameters

Explicit

RBST-392

– TFS

RBST-393

– CHOICE Transport channel type

Dedicated transport channels

RBST-394

– Dynamic transport format information

RBST-395

– RLC Size

336 bits

RBST-396

– Number of TBs and TTI List

3

RBST-397

– Transmission Time Interval

Not Present

RBST-398

– Number of Transport blocks

0

RBST-399

– Transmission Time Interval

Not Present

RBST-400

– Number of Transport blocks

1

RBST-401

– Transmission Time Interval

Not Present

RBST-402

– Number of Transport blocks

4

RBST-403

– CHOICE Logical channel list

ALL

RBST-404

– Semi-static Transport Format information

RBST-405

– Transmission time interval

20

RBST-406

– Type of channel coding

Turbo

RBST-407

– Rate matching attribute

143

RBST-408

– CRC size

16

RBST-409

– DCH quality target

RBST-410

– BLER Quality value

-20 (-2.0)

RBST-411

Frequency info

A1, A3, A4, A5, A6, A7, A8, A9

Not Present

RBST-412

Multi-frequency Info

Not Present

Rel-7

RBST-413

DTX-DRX timing information

Not Present

Rel-7

RBST-414

DRX Information

Not Present

Rel-7

RBST-415

HS-SCCH less Information

Not Present

Rel-7

RBST-416

MIMO parameters

Not Present

Rel-7

RBST-417

Maximum allowed UL TX power

33dBm

RBST-418

CHOICE channel requirement

Uplink DPCH info

Rel-5 and earlier

RBST-419

Uplink DPCH info

Rel-6

RBST-420

– Uplink DPCH power control info

RBST-421

– CHOICE mode

FDD

RBST-422

– DPCCH power offset

-40 (-80dB) IE value will have no effect on the UE UL power when closed loop power control is active

RBST-423

– PC Preamble

1 frame

RBST-424

– SRB delay

7 frames

RBST-425

– Power Control Algorithm

Algorithm1

RBST-426

– TPC step size

0 (1dB)

RBST-427

– ACK

Not Present

Rel-5

RBST-428

– NACK

Not Present

Rel-5

RBST-429

– Ack-Nack repetition factor

Not Present

Rel-5

RBST-430

– CHOICE mode

FDD

RBST-431

– Scrambling code type

Long

RBST-432

– Scrambling code number

0 (0 to 16777215)

RBST-433

– Number of DPDCH

1

RBST-434

– spreading factor

A1, A3, A4, A5, A6, A7, A8, A9

64

RBST-435

– TFCI existence

A1, A3, A4, A5, A6, A7, A8, A9

TRUE

RBST-436

– Number of FBI bit

Not Present(0)

RBST-437

– Puncturing Limit

1

RBST-438

CHOICE Mode

FDD

R99 and Rel-4 only

RBST-439

– Downlink PDSCH information

Not Present

R99 and Rel-4 only

RBST-440

E-DCH Info

Not Present

Rel-6

RBST-441

Downlink HS-PDSCH Information

Not Present

Rel-5

RBST-442

Downlink information common for all radio links

RBST-443

– Downlink DPCH info common for all RL

RBST-444

– Timing indicator

Maintain

RBST-445

– CFN-targetSFN frame offset

Not Present

RBST-446

– Downlink DPCH power control information

RBST-447

– CHOICE mode

FDD

RBST-448

– DPC mode

0 (single)

RBST-449

– CHOICE mode

FDD

RBST-450

– Power offset PPilot-DPDCH

0

RBST-451

– DL rate matching restriction information

Not Present

RBST-452

– Spreading factor

A1

128

RBST-453

– Fixed or Flexible Position

Fixed

RBST-454

– TFCI existence

TRUE

RBST-455

– CHOICE SF

128

RBST-456

– Number of bits for Pilot bits

8

RBST-457

– Spreading factor

A3, A6, A9

32

RBST-458

– Fixed or Flexible Position

Fixed

RBST-459

– TFCI existence

TRUE

RBST-460

– CHOICE SF

32

RBST-461

– Spreading factor

A4, A7

16

RBST-462

– Fixed or Flexible Position

Fixed

RBST-463

– TFCI existence

TRUE

RBST-464

– CHOICE SF

16

RBST-465

– Spreading factor

A5, A8

8

RBST-466

– Fixed or Flexible Position

Fixed

RBST-467

– TFCI existence

TRUE

RBST-468

– CHOICE SF

8

RBST-469

– CHOICE mode

A1, A3, A4, A5, A6, A7, A8, A9

FDD

RBST-470

– DPCH compressed mode info

Not Present

RBST-471

– TX Diversity mode

None

RBST-472

– SSDT information

Not Present

R99 and Rel-4 only

RBST-473

– Default DPCH Offset Value

Not Present

RBST-474

– MAC-hs reset indicator

Not Present

Rel-5

RBST-475

Downlink information per radio link list

RBST-476

– Downlink information for each radio link

RBST-477

– CHOICE mode

FDD

RBST-478

– Primary CPICH info

RBST-479

– Primary scrambling code

Reference to clause 6.1 "Default settings (FDD)"

RBST-480

– PDSCH with SHO DCH info

Not Present

R99 and Rel-4 only

RBST-481

– PDSCH code mapping

Not Present

R99 and Rel-4 only

RBST-482

– Serving HS-DSCH radio link indicator

FALSE

Rel-5

RBST-483

– Downlink DPCH info for each RL

RBST-484

– CHOICE mode

FDD

RBST-485

– Primary CPICH usage for channel estimation

Primary CPICH may be used

RBST-486

– DPCH frame offset

Set to value Default DPCH Offset Value (as currently stored in SS) mod 38 400

RBST-487

– Secondary CPICH info

Not Present

RBST-488

– DL channelisation code

RBST-489

– Secondary scrambling code

Not Present

RBST-490

– Spreading factor

A1

128

RBST-491

– Code number

96

RBST-492

– Spreading factor

A3, A6, A9

32

RBST-493

– Code number

24

RBST-494

– Spreading factor

A4, A7

16

RBST-495

– Code number

12

RBST-496

– Spreading factor

A5, A8

8

RBST-497

– Code number

6

RBST-498

– Scrambling code change

A1, A3, A4, A5, A6, A7, A8, A9

No change

RBST-499

– TPC combination index

0

RBST-500

– SSDT Cell Identity

Not Present

R99 and Rel-4 only

RBST-501

– Closed loop timing adjustment mode

Not Present

RBST-502

– SCCPCH information for FACH

Not Present

R99 and Rel-4 only

RBST-503

MBMS PL Service Restriction Information

Not Present

Rel-6

RBST-504

Condition

Explanation

Version

A1

This IE is needed for "UE supports CS RAB for Test Loop Mode1 RMC 12.2/12.2 (TM)"

A2

Not used

A3

This IE is needed for "UE supports CS RAB for Test Loop Mode1 AMC 12.2/64 (AM)"

A4

This IE is needed for "UE supports CS RAB for Test Loop Mode1 AMC 12.2/144 (AM)"

A5

This IE is needed for "UE supports CS RAB for Test Loop Mode1 AMC 12.2/384 (AM)"

A6

This IE is needed for "UE supports PS RAB for Test Loop Mode1 AMC 12.2/64 (AM)"

A7

This IE is needed for "UE supports PS RAB for Test Loop Mode1 AMC 12.2/144 (AM)"

A8

This IE is needed for "UE supports PS RAB for Test Loop Mode1 AMC 12.2/384 (AM)"

A9

This IE is needed for "UE supports PS RAB for Test Loop Mode1 AMC 12.2/64(Channel2) (AM)"

Contents of RADIO BEARER SETUP message: AM or UM (UE supports PS RAB only)

Information Element

Value/remark

Version

Index

Message Type

RBSP-001

RRC transaction identifier

Arbitrarily selects an integer between 0 and 3

RBSP-002

Integrity check info

RBSP-003

– message authentication code

SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I.

RBSP-004

– RRC message sequence number

SS provides the value of this IE, from its internal counter.

RBSP-005

Integrity protection mode info

Not Present

RBSP-006

Ciphering mode info

Not Present

RBSP-007

Activation time

(256+CFN-(CFN MOD 8 + 8))MOD 256

RBSP-008

New U-RNTI

Not Present

RBSP-009

New C-RNTI

Not Present

RBSP-010

New DSCH-RNTI

Not Present

R99 and Rel-4 only

RBSP-011

New H-RNTI

Not Present

Rel-5

RBSP-012

New Primary E-RNTI

Not Present

Rel-6

RBSP-013

New Secondary E-RNTI

Not Present

Rel-6

RBSP-014

RRC State indicator

CELL_DCH

RBSP-015

UTRAN DRX cycle length coefficient

Not Present

RBSP-016

CN information info

Not Present

RBSP-017

URA identity

Not Present

RBSP-018

CHOICE specification mode

Complete specification

Rel-6

RBSP-019

– Signalling RB information to setup

Not Present

RBSP-020

– RAB information for setup list

RBSP-021

– RAB information for setup

RBSP-022

– RAB info

(AM DTCH for PS domain)

RBSP-023

– RAB identity

0000 0101B

The first/ leftmost bit of the bit string contains the most significant bit of the RAB identity.

RBSP-024

– CN domain identity

PS domain

RBSP-025

– NAS Synchronization Indicator

Not Present

RBSP-026

– Re-establishment timer

useT315

RBSP-027

– RB information to setup

RBSP-028

– RB identity

20

RBSP-029

– PDCP info

RBSP-030

– Support for lossless SRNS relocation

FALSE

RBSP-031

– Max PDCP SN window size

Not present

RBSP-032

– PDCP PDU header

Absent

RBSP-033

– Header compression information

Not present

RBSP-034

– CHOICE RLC info type

RLC info

RBSP-035

– CHOICE Uplink RLC mode

AM RLC

RBSP-036

– Transmission RLC discard

RBSP-037

– CHOICE SDU discard mode

No Discard

RBSP-038

– MAX_DAT

15

RBSP-039

– Transmission window size

128

RBSP-040

– Timer_RST

500

RBSP-041

– Max_RST

4

RBSP-042

– Polling info

RBSP-043

– Timer_poll_prohibit

200

RBSP-044

– Timer_poll

200

RBSP-045

– Poll_PDU

Not Present

RBSP-046

– Poll_SDU

1

RBSP-047

– Last transmission PDU poll

TRUE

RBSP-048

– Last retransmission PDU poll

TRUE

RBSP-049

– Poll_Windows

99

RBSP-050

– Timer_poll_periodic

Not Present

RBSP-051

– CHOICE Downlink RLC mode

AM RLC

RBSP-052

– DL RLC PDU size

Reference to clause 6 Parameter Set

Rel-5

RBSP-053

– In-sequence delivery

TRUE

RBSP-054

– Receiving window size

128

RBSP-055

– Downlink RLC status info

RBSP-056

– Timer_status_prohibit

200

RBSP-057

– Timer_EPC

Not Present

RBSP-058

– Missing PDU indicator

TRUE

RBSP-059

– Timer_STATUS_periodic

Not Present

RBSP-060

– RB mapping info

RBSP-061

– Information for each multiplexing option

2 RBMuxOptions

RBSP-062

– RLC logical channel mapping indicator

Not Present

RBSP-063

– Number of uplink RLC logical channels

1

RBSP-064

– Uplink transport channel type

DCH

RBSP-065

– UL Transport channel identity

1

RBSP-066

– Logical channel identity

Not Present

RBSP-067

– CHOICE RLC size list

Configured

RBSP-068

– MAC logical channel priority

8

RBSP-069

– Downlink RLC logical channel info

RBSP-070

– Number of downlink RLC logical channels

1

RBSP-071

– Downlink transport channel type

DCH

RBSP-072

– DL DCH Transport channel identity

6

RBSP-073

– DL DSCH Transport channel identity

Not Present

RBSP-074

– Logical channel identity

Not Present

RBSP-075

– RLC logical channel mapping indicator

Not Present

RBSP-076

– Number of uplink RLC logical channels

1

RBSP-077

– Uplink transport channel type

RACH

RBSP-078

– UL Transport channel identity

Not Present

RBSP-079

– Logical channel identity

7

RBSP-080

– CHOICE RLC size list

Explicit list

RBSP-081

– RLC size index

Reference to clause 6 Parameter Set

RBSP-082

– MAC logical channel priority

8

RBSP-083

– Downlink RLC logical channel info

RBSP-084

– Number of downlink RLC logical channels

1

RBSP-085

– Downlink transport channel type

FACH

RBSP-086

– DL DCH Transport channel identity

Not Present

RBSP-087

– DL DSCH Transport channel identity

Not Present

RBSP-088

– Logical channel identity

7

RBSP-089

RB information to reconfigure list

Not Present

Rel-6

RBSP-090

RB information to be affected list

Not Present

RBSP-091

Downlink counter synchronization info

Not Present

RBSP-092

UL Transport channel information for all transport channels

RBSP-093

– PRACH TFCS

Not Present

RBSP-094

– CHOICE mode

FDD

RBSP-095

– TFC subset

Not Present

RBSP-096

– UL DCH TFCS

RBSP-097

– CHOICE TFCI signalling

Normal

RBSP-098

– TFCI Field 1 information

RBSP-099

– CHOICE TFCS representation

Complete reconfiguration

RBSP-100

– TFCS complete reconfigure information

RBSP-101

– CHOICE CTFC Size

Number of bits used must be enough to cover all combinations of CTFC from clause 6.10.2.4 Parameter Set.

RBSP-102

– CTFC information

This IE is repeated for TFC numbers and reference to clause 6.10.2.4 Parameter Set

RBSP-103

– CTFC

Reference to clause 6.10.2.4 Parameter Set

RBSP-104

– Power offset information

RBSP-105

– CHOICE Gain Factors

Computed Gain Factors(The last TFC is set to Signalled Gain Factors)

RBSP-106

– Gain factor βc

11 (below 64 kbps)

9 (higher than 64 kbps) (Not Present if the CHOICE Gain Factors is set to Computed Gain Factors)

RBSP-107

– Gain factor βd

15

(Not Present if the CHOICE Gain Factors is set to Computed Gain Factors)

RBSP-108

– Reference TFC ID

0

RBSP-109

– CHOICE mode

FDD

RBSP-110

– Power offset P p-m

Not Present

RBSP-111

Deleted UL TrCH information list

Not Present

RBSP-112

Added or Reconfigured UL TrCH information list

1

RBSP-113

Added or Reconfigured UL TrCH information

1 DCH added, 1 DCH reconfigured

RBSP-114

– Uplink transport channel type

DCH

RBSP-115

– UL Transport channel identity

1

RBSP-116

– TFS

RBSP-117

– CHOICE Transport channel type

Dedicated transport channels

RBSP-118

– Dynamic Transport format information

RBSP-119

– RLC Size

Reference to clause 6.10 Parameter Set

RBSP-120

– Number of TBs and TTI List

(This IE is repeated for TFI number.)

RBSP-121

– Transmission Time Interval

Not Present

RBSP-122

– Number of Transport blocks

Reference to clause 6.10 Parameter Set

RBSP-123

– CHOICE Logical channel list

All

RBSP-124

– Semi-static Transport Format information

RBSP-125

– Transmission time interval

Reference to clause 6.10 Parameter Set

RBSP-126

– Type of channel coding

Reference to clause 6.10 Parameter Set

RBSP-127

– Coding Rate

Reference to clause 6.10 Parameter Set

RBSP-128

– Rate matching attribute

Reference to clause 6.10 Parameter Set

RBSP-129

– CRC size

Reference to clause 6.10 Parameter Set

RBSP-130

– Uplink transport channel type

DCH

RBSP-131

– UL Transport channel identity

5

RBSP-132

– TFS

RBSP-133

– CHOICE Transport channel type

Dedicated transport channels

RBSP-134

– Dynamic Transport format information

RBSP-135

– RLC Size

Reference to clause 6.10 Parameter Set

RBSP-136

– Number of TBs and TTI List

(This IE is repeated for TFI number.)

RBSP-137

– Transmission Time Interval

Not Present

RBSP-138

– Number of Transport blocks

Reference to clause 6.10 Parameter Set

RBSP-139

– CHOICE Logical channel list

All

RBSP-140

– Semi-static Transport Format information

RBSP-141

– Transmission time interval

Reference to clause 6.10 Parameter Set

RBSP-142

– Type of channel coding

Reference to clause 6.10 Parameter Set

RBSP-143

– Coding Rate

Reference to clause 6.10 Parameter Set

RBSP-144

– Rate matching attribute

Reference to clause 6.10 Parameter Set

RBSP-145

– CRC size

Reference to clause 6.10 Parameter Set

RBSP-146

CHOICE mode

Not Present

RBSP-147

DL Transport channel information common for all transport channel

RBSP-148

– SCCPCH TFCS

Not Present

RBSP-149

– CHOICE mode

FDD

RBSP-150

– CHOICE DL parameters

Explicit

RBSP-151

– DL DCH TFCS

RBSP-152

– CHOICE TFCI Signalling

Normal

RBSP-153

– TFCI Field 1 Information

RBSP-154

– CHOICE TFCS representation

Complete reconfiguration

RBSP-155

– TFCS complete reconfigure

RBSP-156

– CHOICE CTFC Size

Number of bits used must be enough to cover all combinations of CTFC from clause 6.10.2.4 Parameter Set.

RBSP-157

– CTFC information

This IE is repeated for TFC numbers and reference to clause 6.10.2.4

RBSP-158

– CTFC

Reference to clause 6.10.2.4 Parameter Set

RBSP-159

– Power offset information

Not Present

RBSP-160

Added or Reconfigured DL TrCH information list

1

RBSP-161

Added or Reconfigured DL TrCH information

2 TrCHs(DCH for DCCH and DCH for DTCH)

RBSP-162

– Downlink transport channel type

DCH

RBSP-163

– DL Transport channel identity

10

RBSP-164

– CHOICE DL parameters

Same as UL

RBSP-165

– Uplink transport channel type

DCH

RBSP-166

– UL TrCH identity

5

RBSP-167

– DCH quality target

RBSP-168

– BLER Quality value

-20 (-2.0)

RBSP-169

– Downlink transport channel type

DCH

RBSP-170

– DL Transport channel identity

6

RBSP-171

– CHOICE DL parameters

Explicit

RBSP-172

– TFS

RBSP-173

– CHOICE Transport channel type

Dedicated transport channel

RBSP-174

– Dynamic transport format information

RBSP-175

– RLC Size

Reference to clause 6.10 Parameter Set

RBSP-176

– Number of TBs and TTI List

(This IE is repeated for TFI number.)

RBSP-177

– Dynamic transport format information

RBSP-178

– Transmission Time Interval

Not Present

RBSP-179

– Number of Transport blocks

Reference to clause 6.10 Parameter Set

RBSP-180

– CHOICE Logical channel list

All

RBSP-181

– Semi-static Transport Format information

RBSP-182

– Transmission time interval

Reference to clause 6.10 Parameter Set

RBSP-183

– Type of channel coding

Reference to clause 6.10 Parameter Set

RBSP-184

– Coding Rate

Reference to clause 6.10 Parameter Set

RBSP-185

– Rate matching attribute

Reference to clause 6.10 Parameter Set

RBSP-186

– CRC size

Reference to clause 6.10 Parameter Set

RBSP-187

– DCH quality target

RBSP-188

– BLER Quality value

-20 (-2.0)

RBSP-189

Frequency info

Not Present

RBSP-190

Multi-frequency Info

Not present

Rel-7

RBSP-191

DTX-DRX timing information

Not present

Rel-7

RBSP-192

DRX Information

Not present

Rel-7

RBSP-193

HS-SCCH less Information

Not present

Rel-7

RBSP-194

MIMO parameters

Not present

Rel-7

RBSP-195

Maximum allowed UL TX power

33dBm

RBSP-196

CHOICE channel requirement

Uplink DPCH info

Rel-5 and earlier

RBSP-197

Uplink DPCH info

Rel-6

RBSP-198

– Uplink DPCH power control info

RBSP-199

– CHOICE mode

FDD

RBSP-200

– DPCCH power offset

-40 (-80dB) IE value will have no effect on the UE UL power when closed loop power control is active

RBSP-201

– PC Preamble

1 frame

RBSP-202

– SRB delay

7 frames

RBSP-203

– Power Control Algorithm

Algorithm1

RBSP-204

– TPC step size

0 (1dB)

RBSP-205

– ACK

Not Present

Rel-5

RBSP-206

– NACK

Not Present

Rel-5

RBSP-207

– Ack-Nack repetition factor

Not Present

Rel-5

RBSP-208

– CHOICE mode

FDD

RBSP-209

– Scrambling code type

Long

RBSP-210

– Scrambling code number

0 (0 to 16777215)

RBSP-211

– Number of DPDCH

1

RBSP-212

– spreading factor

64

RBSP-213

– TFCI existence

TRUE

RBSP-214

– Number of FBI bit

Not Present(0)

RBSP-215

– Puncturing Limit

1

RBSP-216

CHOICE Mode

FDD

R99 and Rel-4 only

RBSP-217

E-DCH Info

Not Present

Rel-6

RBSP-218

– Downlink PDSCH information

Not Present

R99 and Rel-4 only

RBSP-219

Downlink HS-PDSCH Information

Not Present

Rel-5

RBSP-220

Downlink information common for all radio links

RBSP-221

– Downlink DPCH info common for all RL

RBSP-222

– Timing indicator

Maintain

RBSP-223

– CFN-targetSFN frame offset

Not Present

RBSP-224

– Downlink DPCH power control information

RBSP-225

– CHOICE mode

FDD

RBSP-226

– DPC mode

0 (single)

RBSP-227

– CHOICE mode

FDD

RBSP-228

– Power offset PPilot-DPDCH

0

RBSP-229

– DL rate matching restriction information

Not Present

RBSP-230

– Spreading factor

Reference to clause 6.10 Parameter Set

RBSP-231

– Fixed or Flexible Position

Reference to clause 6.10 Parameter Set

RBSP-232

– TFCI existence

Reference to clause 6.10 Parameter Set

RBSP-233

– CHOICE SF

Reference to clause 6.10 Parameter Set

RBSP-234

– CHOICE mode

FDD

RBSP-235

– DPCH compressed mode info

Not Present

RBSP-236

– TX Diversity mode

None

RBSP-237

– SSDT information

Not Present

R99 and Rel-4 only

RBSP-238

– Default DPCH Offset Value

Not Present

RBSP-239

– MAC-hs reset indicator

Not Present

Rel-5

RBSP-240

– Post-verification period

Not Present

Rel-6

RBSP-241

Downlink information per radio link list

RBSP-242

– Downlink information for each radio link

RBSP-243

– CHOICE mode

FDD

RBSP-244

– Primary CPICH info

RBSP-245

– Primary scrambling code

Reference to clause 6.1 "Default settings (FDD)"

RBSP-246

– PDSCH with SHO DCH info

Not Present

R99 and Rel-4 only

RBSP-247

– PDSCH code mapping

Not Present

R99 and Rel-4 only

RBSP-248

– Downlink DPCH info for each RL

RBSP-249

– CHOICE mode

FDD

RBSP-250

– Primary CPICH usage for channel estimation

Primary CPICH may be used

RBSP-251

– DPCH frame offset

Set to value Default DPCH Offset Value (as currently stored in SS) mod 38 400

RBSP-252

– Secondary CPICH info

Not Present

RBSP-253

– DL channelisation code

RBSP-254

– Secondary scrambling code

Not present

RBSP-255

– Spreading factor

Reference to clause 6.10 Parameter Set

RBSP-256

– Code number

Depends upon radio bearer used.

RBSP-257

– Scrambling code change

No change

RBSP-258

– TPC combination index

0

RBSP-259

– SSDT Cell Identity

Not Present

R99 and Rel-4 only

RBSP-260

– Closed loop timing adjustment mode

Not Present

RBSP-261

– SCCPCH information for FACH

Not Present

R99 and Rel-4 only

RBSP-262

MBMS PL Service Restriction Information

Not Present

Rel-6

RBSP-263

Contents of RADIO BEARER SETUP message: AM or UM (UE supports CS RAB for Test Loop Mode 2)

Information Element

Value/remark

Version

Index

Message Type

RBSC-001

RRC transaction identifier

Arbitrarily selects an integer between 0 and 3

RBSC-002

Integrity check info

RBSC-003

– message authentication code

SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I.

RBSC-004

– RRC message sequence number

SS provides the value of this IE, from its internal counter.

RBSC-005

Integrity protection mode info

Not Present

RBSC-006

Ciphering mode info

Not Present

RBSC-007

Activation time

(256+CFN-(CFN MOD 8 + 8))MOD 256

RBSC-008

New U-RNTI

Not Present

RBSC-009

New C-RNTI

Not Present

RBSC-010

New DSCH-RNTI

Not Present

R99 and Rel-4 only

RBSC-011

New H-RNTI

Not Present

Rel-5

RBSC-012

New Primary E-RNTI

Not Present

Rel-6

RBSC-013

New Secondary E-RNTI

Not Present

Rel-6

RBSC-014

RRC State indicator

CELL_DCH

RBSC-015

UTRAN DRX cycle length coefficient

Not Present

RBSC-016

CN information info

Not Present

RBSC-017

URA identity

Not Present

RBSC-018

CHOICE specification mode

Complete specification

Rel-6

RBSC-019

Signalling RB information to setup

Not Present

RBSC-020

RAB information for setup list

RBSC-021

– RAB information for setup

RBSC-022

– RAB info

RBSC-023

– RAB identity

0000 0001B

The first/ leftmost bit of the bit string contains the most significant bit of the RAB identity.

RBSC-024

– CN domain identity

CS domain

RBSC-025

– NAS Synchronization Indicator

Not Present

RBSC-026

– Re-establishment timer

UseT314

RBSC-027

– RB information to setup list

RBSC-028

– RB information to setup

RBSC-029

– RB identity

10

RBSC-030

– PDCP info

Not Present

RBSC-031

– CHOICE RLC info type

RLC info

RBSC-032

– CHOICE Uplink RLC mode

TM RLC

RBSC-033

– Transmission RLC discard

Not Present

RBSC-034

– Segmentation indication

FALSE

RBSC-035

– CHOICE Downlink RLC mode

TM RLC

RBSC-036

– Segmentation indication

FALSE

RBSC-037

– RB mapping info

RBSC-038

– Information for each multiplexing option

RBSC-039

– RLC logical channel mapping indicator

Not Present

RBSC-040

– Number of uplink RLC logical channels

1

RBSC-041

– Uplink transport channel type

DCH

RBSC-042

– UL Transport channel identity

1

RBSC-043

– Logical channel identity

Not Present

RBSC-044

– CHOICE RLC size list

Configured

RBSC-045

– MAC logical channel priority

7

RBSC-046

– Downlink RLC logical channel info

RBSC-047

– Number of downlink RLC logical channels

1

RBSC-048

– Downlink transport channel type

DCH

RBSC-049

– DL DCH Transport channel identity

6

RBSC-050

– DL DSCH Transport channel identity

Not Present

RBSC-051

– Logical channel identity

Not Present

RBSC-052

RB information to reconfigure list

Not Present

Rel-6

RBSC-053

RB information to be affected list

Not Present

RBSC-054

Downlink counter synchronization info

Not Present

RBSC-055

UL Transport channel information for all transport channels

RBSC-056

– PRACH TFCS

Not Present

RBSC-057

– CHOICE mode

FDD

RBSC-058

– TFC subset

Not Present

RBSC-059

– UL DCH TFCS

RBSC-060

– CHOICE TFCI signalling

Normal

RBSC-061

– TFCI Field 1 information

RBSC-062

– CHOICE TFCS representation

Complete reconfiguration

RBSC-063

– TFCS complete reconfigure information

RBSC-064

– CHOICE CTFC Size

2 bit CTFC

RBSC-065

– CTFC information

4 TFCs

RBSC-066

– 2bit CTFC

0

RBSC-067

– Power offset Information

RBSC-068

– CHOICE Gain Factors

Computed Gain Factors

RBSC-069

– Reference TFC ID

0

RBSC-070

– CHOICE mode

FDD

RBSC-071

– Power offset Pp-m

Not Present

RBSC-072

– 2bit CTFC

2

RBSC-073

– Power offset Information

RBSC-074

– CHOICE Gain Factors

Computed Gain Factors

RBSC-075

– Reference TFC ID

0

RBSC-076

– CHOICE mode

FDD

RBSC-077

– Power offset Pp-m

Not Present

RBSC-078

– 2bit CTFC

1

RBSC-079

– Power offset Information

RBSC-080

– CHOICE Gain Factors

Computed Gain Factors

RBSC-081

– Reference TFC ID

0

RBSC-082

– CHOICE mode

FDD

RBSC-083

– Power offset Pp-m

Not Present

RBSC-084

– 2bit CTFC

3

RBSC-085

– Power offset Information

RBSC-086

– CHOICE Gain Factors

Signalled Gain Factors

RBSC-087

– CHOICE mode

FDD

RBSC-088

– Gain factor ßc

8

RBSC-089

– Gain factor ßd

15

RBSC-090

– Reference TFC ID

0

RBSC-091

– CHOICE mode

FDD

RBSC-092

– Power offset Pp-m

Not Present

RBSC-093

Deleted UL TrCH information list

Not Present

RBSC-094

Added or Reconfigured UL TrCH information list

1

RBSC-095

– Added or Reconfigured UL TrCH information

RBSC-096

– Uplink transport channel type

DCH

RBSC-097

– UL Transport channel identity

1

RBSC-098

– TFS

RBSC-099

– CHOICE Transport channel type

Dedicated transport channels

RBSC-100

– Dynamic Transport Format Information

RBSC-101

– RLC size

260 bits

RBSC-102

– Number of TBs and TTI List

2

RBSC-103

– Transmission Time Interval

Not Present

RBSC-104

– Number of Transport blocks

0

RBSC-105

– Transmission Time Interval

Not Present

RBSC-106

– Number of Transport blocks

1

RBSC-107

– CHOICE Logical channel List

ALL

RBSC-108

– Semi-static Transport Format Information

RBSC-109

– Transmission time interval

20

RBSC-110

– Type of channel coding

Convolutional

RBSC-111

– Coding Rate

1/3

RBSC-112

– Rate matching attribute

256

RBSC-113

– CRC size

0

RBSC-114

CHOICE mode

Not Present

RBSC-115

DL Transport channel information common for all transport channel

RBSC-116

– SCCPCH TFCS

Not Present

RBSC-117

– CHOICE mode

FDD

RBSC-118

– CHOICE DL parameters

Same as UL

RBSC-119

Deleted DL TrCH information list

Not Present

RBSC-120

Added or Reconfigured DL TrCH information list

1

RBSC-121

– Added or Reconfigured DL TrCH information

RBSC-122

– Downlink transport channel type

DCH

RBSC-123

– DL Transport channel identity

6

RBSC-124

– CHOICE DL parameters

RBSC-125

– CHOICE Transport channel type

Dedicated transport channels

RBSC-126

– Dynamic Transport Format Information

RBSC-127

– RLC size

244 bits

RBSC-128

– Number of TBs and TTI List

2

RBSC-129

– Transmission Time Interval

Not Present

RBSC-130

– Number of Transport blocks

0

RBSC-131

– Transmission Time Interval

Not Present

RBSC-132

– Number of Transport blocks

1

RBSC-133

– CHOICE Logical channel List

ALL

RBSC-134

– Semi-static Transport Format Information

RBSC-135

– Transmission time interval

20

RBSC-136

– Type of channel coding

Convolutional

RBSC-137

– Coding Rate

1/3

RBSC-138

– Rate matching attribute

256

RBSC-139

– CRC size

16

RBSC-140

– DCH quality target

RBSC-141

– BLER Quality value

-20 (-2.0)

RBSC-142

Frequency info

Not Present

RBSC-143

Multi-frequency Info

Not present

Rel-7

RBSC-144

DTX-DRX timing information

Not present

Rel-7

RBSC-145

DRX Information

Not present

Rel-7

RBSC-146

HS-SCCH less Information

Not present

Rel-7

RBSC-147

MIMO parameters

Not present

Rel-7

RBSC-148

Maximum allowed UL TX power

33dBm

RBSC-149

CHOICE channel requirement

Uplink DPCH info

Rel-5 and earlier

RBSC-150

Uplink DPCH info

Rel-6

RBSC-151

– Uplink DPCH power control info

RBSC-152

– CHOICE mode

FDD

RBSC-153

– DPCCH power offset

-40 (-80dB) IE value will have no effect on the UE UL power when closed loop power control is active

RBSC-154

– PC Preamble

1 frame

RBSC-155

– SRB delay

7 frames

RBSC-156

– Power Control Algorithm

Algorithm1

RBSC-157

– TPC step size

0 (1dB)

RBSC-158

– ACK

Not Present

Rel-5

RBSC-159

– NACK

Not Present

Rel-5

RBSC-160

– Ack-Nack repetition factor

Not Present

Rel-5

RBSC-161

– CHOICE mode

FDD

RBSC-162

– Scrambling code type

Long

RBSC-163

– Scrambling code number

0 (0 to 16777215)

RBSC-164

– Number of DPDCH

1

RBSC-165

– spreading factor

64

RBSC-166

– TFCI existence

TRUE

RBSC-167

– Number of FBI bit

Not Present(0)

RBSC-168

– Puncturing Limit

1

RBSC-169

CHOICE Mode

FDD

R99 and Rel-4 only

RBSC-170

– Downlink PDSCH information

Not Present

R99 and Rel-4 only

RBSC-171

E-DCH Info

Not Present

Rel-6

RBSC-172

Downlink HS-PDSCH Information

Not Present

Rel-5

RBSC-173

Downlink information common for all radio links

RBSC-174

– Downlink DPCH info common for all RL

RBSC-175

– Timing indicator

Maintain

RBSC-176

– CFN-targetSFN frame offset

Not Present

RBSC-177

– Downlink DPCH power control information

RBSC-178

– CHOICE mode

FDD

RBSC-179

– DPC mode

0 (single)

RBSC-180

– CHOICE mode

FDD

RBSC-181

– Power offset PPilot-DPDCH

0

RBSC-182

– DL rate matching restriction information

Not Present

RBSC-183

– Spreading factor

128

RBSC-184

– Fixed or Flexible Position

Fixed

RBSC-185

– TFCI existence

TRUE

RBSC-186

– CHOICE SF

128

RBSC-187

– Number of bits for Pilot bits

8

RBSC-188

– CHOICE mode

FDD

RBSC-189

– DPCH compressed mode info

Not Present

RBSC-190

– TX Diversity mode

None

RBSC-191

– SSDT information

Not Present

R99 and Rel-4 only

RBSC-192

– Default DPCH Offset Value

Not Present

RBSC-193

– MAC-hs reset indicator

Not Present

Rel-5

RBSC-194

– Post-verification period

Not Present

Rel-6

RBSC-195

Downlink information for per radio link list

RBSC-196

– Downlink information for each radio link

RBSC-197

– CHOICE mode

FDD

RBSC-198

– Primary CPICH info

RBSC-199

– Primary scrambling code

Reference to clause 6.1 "Default settings (FDD)"

RBSC-200

– PDSCH with SHO DCH info

Not Present

R99 and Rel-4 only

RBSC-201

– PDSCH code mapping

Not Present

R99 and Rel-4 only

RBSC-202

– Downlink DPCH info for each RL

RBSC-203

– CHOICE mode

FDD

RBSC-204

– Primary CPICH usage for channel estimation

Primary CPICH may be used

RBSC-205

– DPCH frame offset

Set to value Default DPCH Offset Value (as currently stored in SS) mod 38 400

RBSC-206

– Secondary CPICH info

Not Present

RBSC-207

– DL channelisation code

RBSC-208

– Secondary scrambling code

Not Present

RBSC-209

– Spreading factor

128

RBSC-210

– Code number

96

RBSC-211

– Scrambling code change

No change

RBSC-212

– TPC combination index

0

RBSC-213

– SSDT Cell Identity

Not Present

R99 and Rel-4 only

RBSC-214

– Closed loop timing adjustment mode

Not Present

RBSC-215

– SCCPCH information for FACH

Not Present

R99 and Rel-4 only

RBSC-216

MBMS PL Service Restriction Information

Not Present

Rel-6

RBSC-217

Information Element

Condition

Value/remark

Version

Index

Message Type

A1,A2

RBS2-001

RRC transaction identifier

Arbitrarily selects an integer between 0 and 3

RBS2-002

Integrity check info

RBS2-003

– message authentication code

SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I.

RBS2-004

– RRC message sequence number

SS provides the value of this IE, from its internal counter.

RBS2-005

Integrity protection mode info

Not Present

RBS2-006

Ciphering mode info

Not Present

RBS2-007

Activation time

(256+CFN-(CFN MOD 8 + 8))MOD 256

RBS2-008

New U-RNTI

Not Present

RBS2-009

New C-RNTI

Not Present

RBS2-010

New DSCH-RNTI

Not Present

R99 and Rel-4 only

RBS2-011

New H-RNTI

Not Present

Rel-5

RBS2-012

New Primary E-RNTI

Not Present

Rel-6

RBS2-013

New Secondary E-RNTI

Not Present

Rel-6

RBS2-014

RRC State indicator

CELL_DCH

RBS2-015

UTRAN DRX cycle length coefficient

Not Present

RBS2-016

CN information info

Not Present

RBS2-017

URA identity

Not Present

RBS2-018

CHOICE specification mode

Complete specification

Rel-6

RBS2-019

Signalling RB information to setup

Not Present

RBS2-020

RAB information for setup list

RBS2-021

– RAB information for setup

RBS2-022

– RAB info

RBS2-023

– RAB identity

0000 0001B

The first/ leftmost bit of the bit string contains the most significant bit of the RAB identity.

RBS2-024

– CN domain identity

CS domain

RBS2-025

– NAS Synchronization Indicator

Not Present

RBS2-026

– Re-establishment timer

UseT314

RBS2-027

– RB information to setup list

RBS2-028

– RB information to setup

RBS2-029

– RB identity

10

RBS2-030

– PDCP info

Not Present

RBS2-031

– CHOICE RLC info type

RLC info

RBS2-032

– CHOICE Uplink RLC mode

TM RLC

RBS2-033

– Transmission RLC discard

Not Present

RBS2-034

– Segmentation indication

FALSE

RBS2-035

– CHOICE Downlink RLC mode

TM RLC

RBS2-036

– Segmentation indication

FALSE

RBS2-037

– RB mapping info

RBS2-038

– Information for each multiplexing option

RBS2-039

– RLC logical channel mapping indicator

Not Present

RBS2-040

– Number of uplink RLC logical channels

1

RBS2-041

– Uplink transport channel type

DCH

RBS2-042

– UL Transport channel identity

1

RBS2-043

– Logical channel identity

Not Present

RBS2-044

– CHOICE RLC size list

Configured

RBS2-045

– MAC logical channel priority

7

RBS2-046

– Downlink RLC logical channel info

RBS2-047

– Number of downlink RLC logical channels

1

RBS2-048

– Downlink transport channel type

DCH

RBS2-049

– DL DCH Transport channel identity

6

RBS2-050

– DL DSCH Transport channel identity

Not Present

RBS2-051

– Logical channel identity

Not Present

RBS2-052

RB information to reconfigure list

Not Present

Rel-6

RBS2-053

RB information to be affected list

Not Present

RBS2-054

Downlink counter synchronization info

Not Present

RBS2-055

UL Transport channel information for all transport channels

RBS2-056

– PRACH TFCS

Not Present

RBS2-057

– CHOICE mode

FDD

RBS2-058

– TFC subset

Not Present

RBS2-059

– UL DCH TFCS

RBS2-060

– CHOICE TFCI signalling

Normal

RBS2-061

– TFCI Field 1 information

RBS2-062

– CHOICE TFCS representation

Complete reconfiguration

RBS2-063

– TFCS complete reconfigure information

RBS2-064

– CHOICE CTFC Size

A1

2 bit CTFC

RBS2-065

– CTFC information

4 TFCs

RBS2-066

– 2bit CTFC

0

RBS2-067

– Power offset Information

RBS2-068

– CHOICE Gain Factors

Computed Gain Factors

RBS2-069

– Reference TFC ID

0

RBS2-070

– CHOICE mode

FDD

RBS2-071

– Power offset Pp-m

Not Present

RBS2-072

– 2bit CTFC

2

RBS2-073

– Power offset Information

RBS2-074

– CHOICE Gain Factors

Computed Gain Factors

RBS2-075

– Reference TFC ID

0

RBS2-076

– CHOICE mode

FDD

RBS2-077

– Power offset Pp-m

Not Present

RBS2-078

– 2bit CTFC

1

RBS2-079

– Power offset Information

RBS2-080

– CHOICE Gain Factors

Computed Gain Factors

RBS2-081

– Reference TFC ID

0

RBS2-082

– CHOICE mode

FDD

RBS2-083

– Power offset Pp-m

Not Present

RBS2-084

– 2bit CTFC

3

RBS2-085

– Power offset Information

RBS2-086

– CHOICE Gain Factors

Signalled Gain Factors

RBS2-087

– CHOICE mode

FDD

RBS2-088

– Gain factor ßc

8

RBS2-089

– Gain factor ßd

15

RBS2-090

– Reference TFC ID

0

RBS2-091

– CHOICE mode

FDD

RBS2-092

– Power offset Pp-m

Not Present

RBS2-093

– CHOICE CTFC Size

A2

4 bit CTFC

RBS2-094

– CTFC information

6 TFCs

RBS2-095

– 4bit CTFC

0

RBS2-096

– Power offset Information

RBS2-097

– CHOICE Gain Factors

Computed Gain Factors

RBS2-098

– Reference TFC ID

0

RBS2-099

– CHOICE mode

FDD

RBS2-100

– Power offset Pp-m

Not Present

RBS2-101

– 4bit CTFC

3

RBS2-102

– Power offset Information

RBS2-103

– CHOICE Gain Factors

Computed Gain Factors

RBS2-104

– Reference TFC ID

0

RBS2-105

– CHOICE mode

FDD

RBS2-106

– Power offset Pp-m

Not Present

RBS2-107

– 4bit CTFC

1

RBS2-108

– Power offset Information

RBS2-109

– CHOICE Gain Factors

Computed Gain Factors

RBS2-110

– Reference TFC ID

0

RBS2-111

– CHOICE mode

FDD

RBS2-112

– Power offset Pp-m

Not Present

RBS2-113

– 4bit CTFC

4

RBS2-114

– Power offset Information

RBS2-115

– CHOICE Gain Factors

Computed Gain Factors

RBS2-116

– Reference TFC ID

0

RBS2-117

– CHOICE mode

FDD

RBS2-118

– Power offset Pp-m

Not Present

RBS2-119

– 4bit CTFC

2

RBS2-120

– Power offset Information

RBS2-121

– CHOICE Gain Factors

Computed Gain Factors

RBS2-122

– Reference TFC ID

0

RBS2-123

– CHOICE mode

FDD

RBS2-124

– Power offset Pp-m

Not Present

RBS2-125

– 4bit CTFC

5

RBS2-126

– Power offset Information

RBS2-127

– CHOICE Gain Factors

Signalled Gain Factors

RBS2-128

– CHOICE mode

FDD

RBS2-129

– Gain factor ßc

8

RBS2-130

– Gain factor ßd

15

RBS2-131

– Reference TFC ID

0

RBS2-132

– CHOICE mode

FDD

RBS2-133

– Power offset Pp-m

Not Present

RBS2-134

Deleted UL TrCH information list

A1,A2

Not Present

RBS2-135

Added or Reconfigured UL TrCH information list

1

RBS2-136

– Added or Reconfigured UL TrCH information

RBS2-137

– Uplink transport channel type

DCH

RBS2-138

– UL Transport channel identity

1

RBS2-139

– TFS

RBS2-140

– CHOICE Transport channel type

Dedicated transport channels

RBS2-141

– Dynamic Transport Format Information

A1

RBS2-142

– RLC size

260 bits

RBS2-143

– Number of TBs and TTI List

2

RBS2-144

– Transmission Time Interval

Not Present

RBS2-145

– Number of Transport blocks

0

RBS2-146

– Transmission Time Interval

Not Present

RBS2-147

– Number of Transport blocks

1

RBS2-148

– CHOICE Logical channel List

ALL

RBS2-149

– Dynamic Transport Format Information

A2

RBS2-150

– RLC size

260 bits

RBS2-151

– Number of TBs and TTI List

1

RBS2-152

– Transmission Time Interval

Not Present

RBS2-153

– Number of Transport blocks

0

RBS2-154

– CHOICE Logical channel List

ALL

RBS2-155

– Dynamic Transport Format Information

RBS2-156

– RLC size

16 bits

RBS2-157

– Number of TBs and TTI List

1

RBS2-158

– Transmission Time Interval

Not Present

RBS2-159

– Number of Transport blocks

1

RBS2-160

– CHOICE Logical channel List

ALL

RBS2-161

– Dynamic Transport Format Information

RBS2-162

– RLC size

260 bits

RBS2-163

– Number of TBs and TTI List

1

RBS2-164

– Transmission Time Interval

Not Present

RBS2-165

– Number of Transport blocks

1

RBS2-166

– CHOICE Logical channel List

ALL

RBS2-167

– Semi-static Transport Format Information

A1,A2

RBS2-168

– Transmission time interval

20

RBS2-169

– Type of channel coding

Convolutional

RBS2-170

– Coding Rate

1/3

RBS2-171

– Rate matching attribute

256

RBS2-172

– CRC size

0

RBS2-173

CHOICE mode

Not Present

RBS2-174

DL Transport channel information common for all transport channel

RBS2-175

– SCCPCH TFCS

Not Present

RBS2-176

– CHOICE mode

FDD

RBS2-177

– CHOICE DL parameters

A1

Same as UL

RBS2-178

– CHOICE DL parameters

A2

DL DCH TFCS

RBS2-179

– DL DCH TFCS

RBS2-180

– CHOICE TFCI signalling

Normal

RBS2-181

– TFCI Field 1 information

RBS2-182

– CHOICE TFCS representation

Complete reconfiguration

RBS2-183

– TFCS complete reconfigure information

RBS2-184

– CHOICE CTFC Size

4 bit CTFC

RBS2-185

– CTFC information

4 TFCs

RBS2-186

– 4bit CTFC

0

RBS2-187

– Power offset Information

RBS2-188

– CHOICE Gain Factors

Computed Gain Factors

RBS2-189

– Reference TFC ID

0

RBS2-190

– CHOICE mode

FDD

RBS2-191

– Power offset Pp-m

Not Present

RBS2-192

– 4bit CTFC

2

RBS2-193

– Power offset Information

RBS2-194

– CHOICE Gain Factors

Computed Gain Factors

RBS2-195

– Reference TFC ID

0

RBS2-196

– CHOICE mode

FDD

RBS2-197

– Power offset Pp-m

Not Present

RBS2-198

– 4bit CTFC

1

RBS2-199

– Power offset Information

RBS2-200

– CHOICE Gain Factors

Computed Gain Factors

RBS2-201

– Reference TFC ID

0

RBS2-202

– CHOICE mode

FDD

RBS2-203

– Power offset Pp-m

Not Present

RBS2-204

– 4bit CTFC

3

RBS2-205

– Power offset Information

RBS2-206

– CHOICE Gain Factors

Signalled Gain Factors

RBS2-207

– CHOICE mode

FDD

RBS2-208

– Gain factor ßc

8

RBS2-209

– Gain factor ßd

15

RBS2-210

– Reference TFC ID

0

RBS2-211

– CHOICE mode

FDD

RBS2-212

– Power offset Pp-m

Not Present

RBS2-213

Deleted DL TrCH information list

A1,A2

Not Present

RBS2-214

Added or Reconfigured DL TrCH information list

1

RBS2-215

– Added or Reconfigured DL TrCH information

RBS2-216

– Downlink transport channel type

DCH

RBS2-217

– DL Transport channel identity

6

RBS2-218

– CHOICE DL parameters

RBS2-219

– CHOICE Transport channel type

Dedicated transport channels

RBS2-220

– Dynamic Transport Format Information

A1

RBS2-221

– RLC size

244 bits

RBS2-222

– Number of TBs and TTI List

2

RBS2-223

– Transmission Time Interval

Not Present

RBS2-224

– Number of Transport blocks

0

RBS2-225

– Transmission Time Interval

Not Present

RBS2-226

– Number of Transport blocks

1

RBS2-227

– CHOICE Logical channel List

ALL

RBS2-228

– Dynamic Transport Format Information

A2

RBS2-229

– RLC size

0 bits

RBS2-230

– Number of TBs and TTI List

1

RBS2-231

– Transmission Time Interval

Not Present

RBS2-232

– Number of Transport blocks

1

RBS2-233

– CHOICE Logical channel List

ALL

RBS2-234

– Dynamic Transport Format Information

RBS2-235

– RLC size

244 bits

RBS2-236

– Number of TBs and TTI List

1

RBS2-237

– Transmission Time Interval

Not Present

RBS2-238

– Number of Transport blocks

1

RBS2-239

– CHOICE Logical channel List

ALL

RBS2-240

– Semi-static Transport Format Information

A1,A2

RBS2-241

– Transmission time interval

20

RBS2-242

– Type of channel coding

Convolutional

RBS2-243

– Coding Rate

1/3

RBS2-244

– Rate matching attribute

256

RBS2-245

– CRC size

16

RBS2-246

– DCH quality target

RBS2-247

– BLER Quality value

-20 (-2.0)

RBS2-248

Frequency info

Not Present

RBS2-249

Maximum allowed UL TX power

33dBm

RBS2-250

CHOICE channel requirement

Uplink DPCH info

Rel-5 and earlier

RBS2-251

Uplink DPCH info

Rel-6

RBS2-252

– Uplink DPCH power control info

RBS2-253

– CHOICE mode

FDD

RBS2-254

– DPCCH power offset

-40 (-80dB) IE value will have no effect on the UE UL power when closed loop power control is active

RBS2-255

– PC Preamble

1 frame

RBS2-256

– SRB delay

7 frames

RBS2-257

– Power Control Algorithm

Algorithm1

RBS2-258

– TPC step size

0 (1dB)

RBS2-259

– ACK

Not Present

Rel-5

RBS2-260

– NACK

Not Present

Rel-5

RBS2-261

– Ack-Nack repetition factor

Not Present

Rel-5

RBS2-262

– CHOICE mode

FDD

RBS2-263

– Scrambling code type

Long

RBS2-264

– Scrambling code number

0 (0 to 16777215)

RBS2-265

– Number of DPDCH

1

RBS2-266

– spreading factor

64

RBS2-267

– TFCI existence

TRUE

RBS2-268

– Number of FBI bit

Not Present(0)

RBS2-269

– Puncturing Limit

1

RBS2-270

CHOICE Mode

FDD

R99 and Rel-4 only

RBS2-271

– Downlink PDSCH information

Not Present

R99 and Rel-4 only

RBS2-272

E-DCH Info

Not Present

Rel-6

RBS2-273

Downlink HS-PDSCH Information

Not Present

Rel-5

RBS2-274

Downlink information common for all radio links

RBS2-275

– Downlink DPCH info common for all RL

RBS2-276

– Timing indicator

Maintain

RBS2-277

– CFN-targetSFN frame offset

Not Present

RBS2-278

– Downlink DPCH power control information

RBS2-279

– CHOICE mode

FDD

RBS2-280

– DPC mode

0 (single)

RBS2-281

– CHOICE mode

FDD

RBS2-282

– Power offset PPilot-DPDCH

0

RBS2-283

– DL rate matching restriction information

Not Present

RBS2-284

– Spreading factor

128

RBS2-285

– Fixed or Flexible Position

Fixed

RBS2-286

– TFCI existence

TRUE

RBS2-287

– CHOICE SF

128

RBS2-288

– Number of bits for Pilot bits

8

RBS2-289

– CHOICE mode

FDD

RBS2-290

– DPCH compressed mode info

Not Present

RBS2-291

– TX Diversity mode

None

RBS2-292

– SSDT information

Not Present

R99 and Rel-4 only

RBS2-293

– Default DPCH Offset Value

Not Present

RBS2-294

– MAC-hs reset indicator

Not Present

Rel-5

RBS2-295

– Post-verification period

Not Present

Rel-6

RBS2-296

Downlink information for per radio link list

RBS2-297

– Downlink information for each radio link

RBS2-298

– CHOICE mode

FDD

RBS2-299

– Primary CPICH info

RBS2-300

– Primary scrambling code

Reference to clause 6.1 "Default settings (FDD)"

RBS2-301

– PDSCH with SHO DCH info

Not Present

R99 and Rel-4 only

RBS2-302

– PDSCH code mapping

Not Present

R99 and Rel-4 only

RBS2-303

– Downlink DPCH info for each RL

RBS2-304

– CHOICE mode

FDD

RBS2-305

– Primary CPICH usage for channel estimation

Primary CPICH may be used

RBS2-306

– DPCH frame offset

Set to value Default DPCH Offset Value (as currently stored in SS) mod 38 400

RBS2-307

– Secondary CPICH info

Not Present

RBS2-308

– DL channelisation code

RBS2-309

– Secondary scrambling code

Not Present

RBS2-310

– Spreading factor

128

RBS2-311

– Code number

96

RBS2-312

– Scrambling code change

No change

RBS2-313

– TPC combination index

0

RBS2-314

– SSDT Cell Identity

Not Present

R99 and Rel-4 only

RBS2-315

– Closed loop timing adjustment mode

Not Present

RBS2-316

– SCCPCH information for FACH

Not Present

R99 and Rel-4 only

RBS2-317

MBMS PL Service Restriction Information

Not Present

Rel-6

RBS2-318

Condition

Explanation

A1

This IE is needed for "UE supports CS RAB for Test Loop Mode2 RMC 12.2/12.2 (TM)"

A2

This IE is needed for "UE supports CS RAB for Test Loop Mode2 RMC 0 and 12.2 (TM)"

Contents of RADIO BEARER SETUP message: AM or UM (HSDPA)

Information Element

Value/remark

Version

Index

Message Type

RBSH-001

RRC transaction identifier

Arbitrarily selects an integer between 0 and 3

RBSH-002

Integrity check info

RBSH-003

– message authentication code

SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I.

RBSH-004

– RRC message sequence number

SS provides the value of this IE, from its internal counter.

RBSH-005

Integrity protection mode info

Not Present

RBSH-006

Ciphering mode info

Not Present

RBSH-007

Activation time

Not Present

RBSH-008

New U-RNTI

Not Present

RBSH-009

New C-RNTI

Not Present

RBSH-010

New H-RNTI

‘1010 1010 1010 1010’

Rel-5

RBSH-011

New Primary E-RNTI

Not Present

Rel-6

RBSH-012

New Secondary E-RNTI

Not Present

Rel-6

RBSH-013

RRC State indicator

CELL_DCH

RBSH-014

UTRAN DRX cycle length coefficient

Not Present

RBSH-015

CN information info

Not Present

RBSH-016

URA identity

Not Present

RBSH-017

CHOICE specification mode

Complete specification

Rel-6

RBSH-018

Signalling RB information to setup

Not Present

RBSH-019

RAB information for setup list

RBSH-020

– RAB information for setup

RBSH-021

– RAB info

(high-speed UM DTCH for PS domain)

RBSH-022

– RAB identity

0000 0110B

The first/ leftmost bit of the bit string contains the most significant bit of the RAB identity.

RBSH-023

– CN domain identity

PS domain

RBSH-024

– NAS Synchronization Indicator

Not Present

RBSH-025

– Re-establishment timer

UseT315

RBSH-026

– RB information to setup

RBSH-027

– RB identity

25

RBSH-028

– PDCP info

Not Present

RBSH-029

– CHOICE RLC info type

RLC info

RBSH-030

– CHOICE Uplink RLC mode

Not Present

RBSH-031

– CHOICE Downlink RLC mode

UM RLC

RBSH-032

– DL UM RLC LI size

Selected with DL UM RLC data size

Rel-5

RBSH-033

– One sided RLC re-establishment

FALSE

Rel-5

RBSH-034

– RB mapping info

RBSH-035

– Information for each multiplexing option

1 RBMuxOptions

RBSH-036

– RLC logical channel mapping indicator

Not Present

RBSH-037

– Downlink RLC logical channel info

RBSH-038

– Number of downlink RLC logical channels

1

RBSH-039

– Downlink transport channel type

HS-DSCH

RBSH-040

– DL DCH Transport channel identity

Not Present

RBSH-041

– DL DSCH Transport channel identity

Not Present

RBSH-042

– CHOICE DL MAC header type

MAC-hs

Rel-7

RBSH-043

– DL HS-DSCH MAC-d flow identity

0

RBSH-044

– Logical channel identity

Not Present

RBSH-045

RB information to reconfigure list

Not Present

Rel-6

RBSH-046

RB information to be affected list

Not Present

RBSH-047

Downlink counter synchronization info

Not Present

RBSH-048

PDCP ROHC target mode

Not Present

Rel-5

RBSH-049

UL Transport channel information for all transport channels

RBSH-050

– PRACH TFCS

Not Present

RBSH-051

– CHOICE mode

FDD

RBSH-052

– TFC subset

Not Present

RBSH-053

– UL DCH TFCS

RBSH-054

– CHOICE TFCI signalling

Normal

RBSH-055

– TFCI Field 1 information

RBSH-056

– CHOICE TFCS representation

Complete reconfiguration

RBSH-057

– TFCS complete reconfigure information

RBSH-058

– CHOICE CTFC Size

2 bit CTFC

RBSH-059

– CTFC information

4 TFCs

RBSH-060

– CTFC

Reference to clause TS 34.121 clause C.2.1 Parameter Set

RBSH-061

– Power offset information

RBSH-062

– CHOICE Gain Factors

Computed Gain Factors(The last TFC is set to Signalled Gain Factors)

RBSH-063

– Gain factor βc

8

(Not Present if the CHOICE Gain Factors is set to Computed Gain Factors)

RBSH-064

– Gain factor βd

15

(Not Present if the CHOICE Gain Factors is set to Computed Gain Factors)

RBSH-065

– Reference TFC ID

0

RBSH-066

– CHOICE mode

FDD

RBSH-067

– Power offset P p-m

Not Present

RBSH-068

Deleted UL TrCH information list

Not Present

RBSH-069

Added or Reconfigured TrCH information list

Not Present

RBSH-070

CHOICE mode

Not Present

RBSH-071

DL Transport channel information common for all transport channel

RBSH-072

– SCCPCH TFCS

Not Present

RBSH-073

– CHOICE mode

FDD

RBSH-074

– CHOICE DL parameters

Explicit

RBSH-075

– DL DCH TFCS

RBSH-076

– CHOICE TFCI Signalling

Normal

RBSH-077

– TFCI Field 1 Information

RBSH-078

– CHOICE TFCS representation

Complete reconfiguration

RBSH-079

– TFCS complete reconfigure

RBSH-080

– CHOICE CTFC Size

2 bit CTFC

RBSH-081

– CTFC information

4 TFCs

RBSH-082

– CTFC

Reference to clause TS 34.121 clause C.3.1 Parameter Set

RBSH-083

– Power offset information

Not Present

RBSH-084

Deleted DL TrCH information

Not Present

RBSH-085

Added or Reconfigured DL TrCH information list

1 TrCHs added

RBSH-086

– Added or Reconfigured DL TrCH information

(HS-DSCH for DTCH)

RBSH-087

– Downlink transport channel type

HS-DSCH

Rel-5

RBSH-088

– DL Transport channel identity

Not Present

RBSH-089

– CHOICE DL parameters

HS-DSCH

RBSH-090

– HARQ Info

Rel-5

RBSH-091

– Number of Processes

Reference to TS34.121 [2] Annex C Fixed Reference Channels

RBSH-092

– CHOICE Memory Partitioning

Explicit

RBSH-093

– Memory size

Reference to TS34.121 [2] Annex C Fixed Reference Channels parameter “Number of HARQ Processes”.

RBSH-094

– Process Memory Size

Reference to TS34.121 [2] Annex C Fixed Reference Channels parameter “Number of SML’s per HARQ Proc.”.

RBSH-095

– Additional memory sizes for MIMO

Not Present

Rel-7

RBSH-096

– CHOICE DL MAC header type

MAC-hs

Rel-7

RBSH-097

– Added or reconfigured MAC-d flow

RBSH-098

– MAC-hs queue to add or reconfigure list

(one queue)

Rel-5

RBSH-099

– MAC-hs queue Id

0

RBSH-100

– MAC-d Flow Identity

0

RBSH-101

– T1

50

RBSH-102

– MAC-hs window size

16

RBSH-103

– MAC-d PDU size Info

RBSH-104

– MAC-d PDU size

Reference to TS34.121 [2] Annex C Fixed Reference Channels

RBSH-105

– MAC-d PDU size index

0

RBSH-106

– MAC-hs queue to delete list

Not present

RBSH-107

– DCH quality target

Not present

RBSH-108

Frequency info

Not Present

RBSH-109

Multi-frequency Info

Not present

Rel-7

RBSH-110

DTX-DRX timing information

Not present

Rel-7

RBSH-111

DRX Information

Not present

Rel-7

RBSH-112

HS-SCCH less Information

Not present

Rel-7

RBSH-113

MIMO parameters

Not present

Rel-7

RBSH-114

Maximum allowed UL TX power

33dBm

RBSH-115

CHOICE channel requirement

Uplink DPCH info

Rel-5 and earlier

RBSH-116

Uplink DPCH info

Rel-6

RBSH-117

– Uplink DPCH power control info

RBSH-118

– CHOICE mode

FDD

RBSH-119

– DPCCH power offset

-40 (-80dB) IE value will have no effect on the UE UL power when closed loop power control is active

RBSH-120

– PC Preamble

1 frame

RBSH-121

– SRB delay

7 frames

RBSH-122

– Power Control Algorithm

Algorithm1

RBSH-123

– TPC step size

0 (1dB)

RBSH-124

– ACK

3

Rel-5

RBSH-125

– NACK

3

Rel-5

RBSH-126

– Ack-Nack repetition factor

1

Rel-5

RBSH-127

– CHOICE mode

FDD

RBSH-128

– Scrambling code type

Long

RBSH-129

– Scrambling code number

0 (0 to 16777215)

RBSH-130

– Number of DPDCH

Not Present (1)

RBSH-131

– spreading factor

64

RBSH-132

– TFCI existence

TRUE

RBSH-133

– Number of FBI bit

Not Present(0)

RBSH-134

– Puncturing Limit

1

RBSH-135

CHOICE Mode

FDD

R99 and Rel-4 only

RBSH-136

– Downlink PDSCH information

Not Present

R99 and Rel-4 only

RBSH-137

E-DCH Info

Not Present

Rel-6

RBSH-138

Downlink HS-PDSCH Information

RBSH-139

– HS-SCCH Info

RBSH-140

– CHOICE mode

FDD

RBSH-141

– DL Scrambling Code

RBSH-142

– HS-SCCH Channelisation Code Information

RBSH-143

– HS-SCCH Channelisation Code

2

RBSH-144

– HS-SCCH Channelisation Code

3

RBSH-145

– HS-SCCH Channelisation Code

6

RBSH-146

– HS-SCCH Channelisation Code

7

RBSH-147

– Measurement Feedback Info

RBSH-148

– CHOICE mode

FDD

RBSH-149

– POhsdsch

6 dB

Rel-5

RBSH-150

– CQI Feedback cycle, k

2 ms

Rel-5

RBSH-151

– CQI repetition factor

1

Rel-5

RBSH-152

– CQI

5 (corresponds to 0dB in relative power offset)

Rel-5

RBSH-153

– CHOICE mode

FDD

RBSH-154

– Downlink 64QAM configured

Not Present

Rel-7

RBSH-155

Downlink information common for all radio links

Not Present

RBSH-156

Downlink information per radio link list

RBSH-157

– Downlink information for each radio link

RBSH-158

– CHOICE mode

FDD

RBSH-159

– Primary CPICH info

RBSH-160

– Primary scrambling code

Reference to clause 6.1 "Default settings (FDD)"

RBSH-161

– PDSCH with SHO DCH info

Not Present

R99 and Rel-4 only

RBSH-162

– PDSCH code mapping

Not Present

R99 and Rel-4 only

RBSH-163

– Serving HS-DSCH radio link indicator

TRUE

Rel-5

RBSH-164

– Downlink DPCH info for each RL

RBSH-165

– CHOICE mode

FDD

RBSH-166

– Primary CPICH usage for channel estimation

Primary CPICH may be used

RBSH-167

– DPCH frame offset

Set to value Default DPCH Offset Value (as currently stored in SS) mod 38 400

RBSH-168

– Secondary CPICH info

Not Present

RBSH-169

– DL channelisation code

RBSH-170

– Secondary scrambling code

Not present

RBSH-171

– Spreading factor

128

RBSH-172

– Code number

96

RBSH-173

– Scrambling code change

No change

RBSH-174

– TPC combination index

0

RBSH-175

– SSDT Cell Identity

Not Present

R99 and Rel-4 only

RBSH-176

– Closed loop timing adjustment mode

Not Present

RBSH-177

– SCCPCH information for FACH

Not Present

R99 and Rel-4 only

RBSH-178

MBMS PL Service Restriction Information

Not Present

Rel-6

RBSH-179

Contents of RADIO BEARER SETUP message: BTFD RMC for Test Loop Mode 2

Information Element

Value/remark

Version

Index

Message Type

RBSB-001

RRC transaction identifier

Arbitrarily selects an integer between 0 and 3

RBSB-002

Integrity check info

RBSB-003

– message authentication code

SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I.

RBSB-004

– RRC message sequence number

SS provides the value of this IE, from its internal counter.

RBSB-005

Integrity protection mode info

Not Present

RBSB-006

Ciphering mode info

Not Present.

For correct operation of test loop mode 2 this IE shall be omitted.

RBSB-007

Activation time

(256+CFN-(CFN MOD 8 + 8))MOD 256

RBSB-008

New U-RNTI

Not Present

RBSB-009

New C-RNTI

Not Present

RBSB-010

New DSCH-RNTI

Not Present

R99 and Rel-4 only

RBSB-011

New H-RNTI

Not Present

Rel-5

RBSB-012

New Primary E-RNTI

Not Present

Rel-6

RBSB-013

New Secondary E-RNTI

Not Present

Rel-6

RBSB-014

RRC State indicator

CELL_DCH

RBSB-015

UTRAN DRX cycle length coefficient

Not Present

RBSB-016

CN information info

Not Present

RBSB-017

URA identity

Not Present

RBSB-018

CHOICE specification mode

Complete specification

Rel-5

RBSB-019

– RAB information for setup

RBSB-020

– RAB info

RBSB-021

– RAB identity

0000 0001B

The first/ leftmost bit of the bit string contains the most significant bit of the RAB identity.

RBSB-022

– CN domain identity

CS domain

RBSB-023

– NAS Synchronization Indicator

Not Present

RBSB-024

– Re-establishment timer

UseT314

RBSB-025

– RB information to setup

RBSB-026

– RB identity

10

RBSB-027

– PDCP info

Not Present

RBSB-028

– CHOICE RLC info type

RLC info

RBSB-029

– CHOICE Uplink RLC mode

TM RLC

RBSB-030

– Transmission RLC discard

Not Present

RBSB-031

– Segmentation indication

FALSE

RBSB-032

– CHOICE Downlink RLC mode

TM RLC

RBSB-033

– Segmentation indication

FALSE

RBSB-034

– RB mapping info

RBSB-035

– Information for each multiplexing option

RBSB-036

– RLC logical channel mapping indicator

Not Present

RBSB-037

– Number of uplink RLC logical channels

1

RBSB-038

– Uplink transport channel type

DCH

RBSB-039

– UL Transport channel identity

1

RBSB-040

– Logical channel identity

Not Present

RBSB-041

– CHOICE RLC size list

Configured

RBSB-042

– MAC logical channel priority

7

RBSB-043

– Downlink RLC logical channel info

RBSB-044

– Number of downlink RLC logical channels

1

RBSB-045

– Downlink transport channel type

DCH

RBSB-046

– DL DCH Transport channel identity

6

RBSB-047

– DL DSCH Transport channel identity

Not Present

RBSB-048

– Logical channel identity

Not Present

RBSB-049

RB information to reconfigure list

Not Present

Rel-6

RBSB-050

RB information to be affected

Not Present

RBSB-051

Downlink counter synchronization info

Not Present

RBSB-052

RMC for BTFD

RBSB-053

UL Transport channel information for all transport channels

RBSB-054

– PRACH TFCS

Not Present

RBSB-055

– CHOICE mode

FDD

RBSB-056

– TFC subset

Not Present

RBSB-057

– UL DCH TFCS

RBSB-058

– CHOICE TFCI signalling

Normal

RBSB-059

– TFCI Field 1 information

RBSB-060

– CHOICE TFCS representation

Complete reconfiguration

RBSB-061

– TFCS complete reconfigure information

RBSB-062

– CHOICE CTFC Size

ctfc6Bit

RBSB-063

– ctfc6Bit

22

RBSB-064

– ctfc6

0

RBSB-065

-powerOffsetInformation(OP)

RBSB-066

-gainFactorInformation

ComputedGainFactors

RBSB-067

– Reference TFC ID

0

RBSB-068

– ctfc6

11

RBSB-069

-powerOffsetInformation(OP)

RBSB-070

-gainFactorInformation

ComputedGainFactors

RBSB-071

– Reference TFC ID

0

RBSB-072

– ctfc6

1

RBSB-073

-powerOffsetInformation(OP)

RBSB-074

-gainFactorInformation

ComputedGainFactors

RBSB-075

– Reference TFC ID

0

RBSB-076

– ctfc6

12

RBSB-077

-powerOffsetInformation(OP)

RBSB-078

-gainFactorInformation

SignalledGainFactors

RBSB-079

-modeSpecificInfo

Fdd

RBSB-080

-fdd

RBSB-081

– Gain factor ßc

8

RBSB-082

– Gain factor ßd

15

RBSB-083

– Reference TFC ID

0

RBSB-084

– ctfc6

2

RBSB-085

-powerOffsetInformation(OP)

RBSB-086

-gainFactorInformation

ComputedGainFactors

RBSB-087

– Reference TFC ID

0

RBSB-088

– ctfc6

13

RBSB-089

-powerOffsetInformation(OP)

RBSB-090

-gainFactorInformation

ComputedGainFactors

RBSB-091

– Reference TFC ID

0

RBSB-092

– ctfc6

3

RBSB-093

-powerOffsetInformation(OP)

RBSB-094

-gainFactorInformation

ComputedGainFactors

RBSB-095

– Reference TFC ID

0

RBSB-096

– ctfc6

14

RBSB-097

-powerOffsetInformation(OP)

RBSB-098

-gainFactorInformation

ComputedGainFactors

RBSB-099

– Reference TFC ID

0

RBSB-100

– ctfc6

4

RBSB-101

-powerOffsetInformation(OP)

RBSB-102

-gainFactorInformation

ComputedGainFactors

RBSB-103

– Reference TFC ID

0

RBSB-104

– ctfc6

15

RBSB-105

-powerOffsetInformation(OP)

RBSB-106

-gainFactorInformation

ComputedGainFactors

RBSB-107

– Reference TFC ID

0

RBSB-108

– ctfc6

5

RBSB-109

-powerOffsetInformation(OP)

RBSB-110

-gainFactorInformation

ComputedGainFactors

RBSB-111

– Reference TFC ID

0

RBSB-112

– ctfc6

16

RBSB-113

-powerOffsetInformation(OP)

RBSB-114

-gainFactorInformation

ComputedGainFactors

RBSB-115

– Reference TFC ID

0

RBSB-116

– ctfc6

6

RBSB-117

-powerOffsetInformation(OP)

RBSB-118

-gainFactorInformation

ComputedGainFactors

RBSB-119

– Reference TFC ID

1

RBSB-120

– ctfc6

17

RBSB-121

-powerOffsetInformation(OP)

RBSB-122

-gainFactorInformation

SignalledGainFactors

RBSB-123

-modeSpecificInfo

Fdd

RBSB-124

-fdd

RBSB-125

– Gain factor ßc

11

RBSB-126

– Gain factor ßd

15

RBSB-127

– Reference TFC ID

1

RBSB-128

– ctfc6

7

RBSB-129

-powerOffsetInformation(OP)

RBSB-130

-gainFactorInformation

ComputedGainFactors

RBSB-131

– Reference TFC ID

1

RBSB-132

– ctfc6

18

RBSB-133

-powerOffsetInformation(OP)

RBSB-134

-gainFactorInformation

ComputedGainFactors

RBSB-135

– Reference TFC ID

1

RBSB-136

– ctfc6

8

RBSB-137

-powerOffsetInformation(OP)

RBSB-138

-gainFactorInformation

ComputedGainFactors

RBSB-139

– Reference TFC ID

1

RBSB-140

– ctfc6

19

RBSB-141

-powerOffsetInformation(OP)

RBSB-142

-gainFactorInformation

ComputedGainFactors

RBSB-143

– Reference TFC ID

1

RBSB-144

– ctfc6

9

RBSB-145

-powerOffsetInformation(OP)

RBSB-146

-gainFactorInformation

ComputedGainFactors

RBSB-147

– Reference TFC ID

1

RBSB-148

– ctfc6

20

RBSB-149

-powerOffsetInformation(OP)

RBSB-150

-gainFactorInformation

ComputedGainFactors

RBSB-151

– Reference TFC ID

1

RBSB-152

– ctfc6

10

RBSB-153

-powerOffsetInformation(OP)

RBSB-154

-gainFactorInformation

ComputedGainFactors

RBSB-155

– Reference TFC ID

1

RBSB-156

– ctfc6

21

RBSB-157

-powerOffsetInformation(OP)

RBSB-158

-gainFactorInformation

ComputedGainFactors

RBSB-159

– Reference TFC ID

1

RBSB-160

Added or Reconfigured UL TrCH information list

1

RBSB-161

– Added or Reconfigured UL TrCH information

RBSB-162

– Uplink transport channel type

DCH

RBSB-163

– UL Transport channel identity

1

RBSB-164

– TFS

RBSB-165

– CHOICE Transport channel type

Dedicated transport channels

RBSB-166

-DedicatedDynamicTF-Info

RBSB-167

RLC size

256

RBSB-168

-numberOfTbSizeList

RBSB-169

-NumberOfTransportBlocks

Zero

RBSB-170

-NumberOfTransportBlocks

One

RBSB-171

– Choice Logical channel List

ALL

RBSB-172

RLC size

216

RBSB-173

-numberOfTbSizeList

RBSB-174

-NumberOfTransportBlocks

One

RBSB-175

– Choice Logical channel List

ALL

RBSB-176

RLC size

171

RBSB-177

-numberOfTbSizeList

RBSB-178

-NumberOfTransportBlocks

One

RBSB-179

– Choice Logical channel List

ALL

RBSB-180

RLC size

160

RBSB-181

-numberOfTbSizeList

RBSB-182

-NumberOfTransportBlocks

One

RBSB-183

– Choice Logical channel List

ALL

RBSB-184

RLC size

146

RBSB-185

-numberOfTbSizeList

RBSB-186

-NumberOfTransportBlocks

One

RBSB-187

– Choice Logical channel List

ALL

RBSB-188

RLC size

130

RBSB-189

-numberOfTbSizeList

RBSB-190

-NumberOfTransportBlocks

One

RBSB-191

– Choice Logical channel List

ALL

RBSB-192

RLC size

115

RBSB-193

-numberOfTbSizeList

RBSB-194

-NumberOfTransportBlocks

One

RBSB-195

– Choice Logical channel List

ALL

RBSB-196

RLC size

107

RBSB-197

-numberOfTbSizeList

RBSB-198

-NumberOfTransportBlocks

One

RBSB-199

– Choice Logical channel List

ALL

RBSB-200

RLC size

51

RBSB-201

-numberOfTbSizeList

RBSB-202

-NumberOfTransportBlocks

One

RBSB-203

– Choice Logical channel List

ALL

RBSB-204

RLC size

12

RBSB-205

-numberOfTbSizeList

RBSB-206

-NumberOfTransportBlocks

One

RBSB-207

– Choice Logical channel List

ALL

RBSB-208

-Semistatic Transport Format Information

RBSB-209

-Transmission Time interval

20 ms

RBSB-210

-channelCodingType

Convolutional

RBSB-211

-convolutional

1/3

RBSB-212

– Rate matching attribute

256

RBSB-213

– CRC size

0

RBSB-214

DL Transport channel information common for all transport channel

RBSB-215

– SCCPCH TFCS

Not Present

RBSB-216

– CHOICE mode

FDD

RBSB-217

– CHOICE DL parameters

Explicit

RBSB-218

– DL DCH TFCS

RBSB-219

– CHOICE TFCI signalling

Normal

RBSB-220

– TFCI Field 1 information

RBSB-221

– CHOICE TFCS representation

Complete reconfiguration

RBSB-222

– TFCS complete reconfigure information

RBSB-223

– CHOICE CTFC Size

Ctfc6Bit

RBSB-224

– ctfc6Bit

18

RBSB-225

– ctfc6

9

RBSB-226

– ctfc6

0

RBSB-227

– ctfc6

10

RBSB-228

– ctfc6

1

RBSB-229

– ctfc6

11

RBSB-230

– ctfc6

2

RBSB-231

– ctfc6

12

RBSB-232

– ctfc6

3

RBSB-233

– ctfc6

13

RBSB-234

– ctfc6

4

RBSB-235

– ctfc6

14

RBSB-236

– ctfc6

5

RBSB-237

– ctfc6

15

RBSB-238

– ctfc6

6

RBSB-239

– ctfc6

16

RBSB-240

– ctfc6

7

RBSB-241

– ctfc6

17

RBSB-242

– ctfc6

8

RBSB-243

Deleted DL TrCH information

Not Present

RBSB-244

Added or Reconfigured DL TrCH information list

1

RBSB-245

– Added or Reconfigured DL TrCH information

RBSB-246

– Downlink transport channel type

DCH

RBSB-247

– DL Transport channel identity

6

RBSB-248

– CHOICE DL parameters

Explicit

RBSB-249

– TFS

RBSB-250

– CHOICE Transport channel type

Dedicated transport channels

RBSB-251

-DedicatedDynamicTF-Info

RBSB-252

RLC size

244

RBSB-253

-numberOfTbSizeList

RBSB-254

-NumberOfTransportBlocks

One

RBSB-255

– Choice Logical channel List

ALL

RBSB-256

RLC size

204

RBSB-257

-numberOfTbSizeList

RBSB-258

-NumberOfTransportBlocks

One

RBSB-259

– Choice Logical channel List

ALL

RBSB-260

RLC size

159

RBSB-261

-numberOfTbSizeList

RBSB-262

-NumberOfTransportBlocks

One

RBSB-263

– Choice Logical channel List

ALL

RBSB-264

RLC size

148

RBSB-265

-numberOfTbSizeList

RBSB-266

-NumberOfTransportBlocks

One

RBSB-267

– Choice Logical channel List

ALL

RBSB-268

RLC size

134

RBSB-269

-numberOfTbSizeList

RBSB-270

-NumberOfTransportBlocks

One

RBSB-271

– Choice Logical channel List

ALL

RBSB-272

RLC size

118

RBSB-273

-numberOfTbSizeList

RBSB-274

-NumberOfTransportBlocks

One

RBSB-275

– Choice Logical channel List

ALL

RBSB-276

RLC size

103

RBSB-277

-numberOfTbSizeList

RBSB-278

-NumberOfTransportBlocks

One

RBSB-279

– Choice Logical channel List

ALL

RBSB-280

RLC size

95

RBSB-281

-numberOfTbSizeList

RBSB-282

-NumberOfTransportBlocks

One

RBSB-283

– Choice Logical channel List

ALL

RBSB-284

RLC size

39

RBSB-285

-numberOfTbSizeList

RBSB-286

-NumberOfTransportBlocks

One

RBSB-287

– Choice Logical channel List

ALL

RBSB-288

-Semistatic Transport Format Information

RBSB-289

-Transmission Time interval

20 ms

RBSB-290

-channelCodingType

Convolutional

RBSB-291

-convolutional

1/3

RBSB-292

– Rate matching attribute

256

RBSB-293

– CRC size

12

RBSB-294

– DCH quality target

RBSB-295

– BLER Quality value

-20 (-2.0)

RBSB-296

– Transparent mode signalling info

Not Present

RBSB-297

Frequency info

Not Present

RBSB-298

Multi-frequency Info

Not present

Rel-7

RBSB-299

DTX-DRX timing information

Not present

Rel-7

RBSB-300

DRX Information

Not present

Rel-7

RBSB-301

HS-SCCH less Information

Not present

Rel-7

RBSB-302

MIMO parameters

Not present

Rel-7

RBSB-303

Maximum allowed UL TX power

33 dBm

RBSB-304

CHOICE channel requirement

Uplink DPCH info

Rel-5 and earlier

RBSB-305

Uplink DPCH info

Rel-6

RBSB-306

– Uplink DPCH power control info

RBSB-307

– DPCCH power offset

-40 (-80dB) IE value will have no effect on the UE UL power when closed loop power control is active

RBSB-308

– PC Preamble

1 frame

RBSB-309

– SRB delay

7 frames

RBSB-310

– Power Control Algorithm

Algorithm1

RBSB-311

– TPC step size

0 (1dB)

RBSB-312

– ACK

Not Present

Rel-5

RBSB-313

– NACK

Not Present

Rel-5

RBSB-314

– Ack-Nack repetition factor

Not Present

Rel-5

RBSB-315

– Scrambling code type

Long

RBSB-316

– Scrambling code number

0

RBSB-317

– Number of DPDCH

1

RBSB-318

– spreading factor

64

RBSB-319

– TFCI existence

TRUE

RBSB-320

– Number of FBI bit

Not Present(0)

RBSB-321

– Puncturing Limit

1

RBSB-322

CHOICE Mode

FDD

R99 and Rel-4 only

RBSB-323

– Downlink PDSCH information

Not Present(0)

R99 and Rel-4 only

RBSB-324

E-DCH Info

Not Present

Rel-6

RBSB-325

Downlink HS-PDSCH Information

Not Present

Rel-5

RBSB-326

Downlink information common for all radio links

RBSB-327

– Downlink DPCH info common for all RL

FDD

RBSB-328

– Timing indicator

Maintain

RBSB-329

– CFN-targetSFN frame offset

Not Present

RBSB-330

– Downlink DPCH power control information

RBSB-331

– DPC mode

0 (single)

RBSB-332

– CHOICE mode

FDD

RBSB-333

– Power offset PPilot-DPDCH

0

RBSB-334

– DL rate matching restriction information

Not Present

RBSB-335

– Spreading factor

128

RBSB-336

– Number of bits for Pilot bits(SF=128,256)

4

RBSB-337

– Fixed or Flexible Position

Fixed

RBSB-338

– TFCI existence

FALSE

RBSB-339

– DPCH compressed mode info

Not Present

RBSB-340

– TX Diversity mode

None

RBSB-341

– SSDT information

Not Present

R99 and Rel-4 only

RBSB-342

– Default DPCH Offset Value

Not Present

RBSB-343

Downlink information for each radio link list

RBSB-344

– Primary CPICH info

RBSB-345

– Primary scrambling code

Reference to clause 6.1 "Default settings (FDD)"

RBSB-346

– PDSCH with SHO DCH info

Not Present

R99 and Rel-4 only

RBSB-347

– PDSCH code mapping

Not Present

R99 and Rel-4 only

RBSB-348

– Downlink DPCH info for each RL

RBSB-349

– Primary CPICH usage for channel estimation

Primary CPICH may be used

RBSB-350

– DPCH frame offset

Set to value Default DPCH Offset Value (as currently stored in SS) mod 38 400

RBSB-351

– Secondary CPICH info

Not Present

RBSB-352

– DL channelisation code

RBSB-353

– Secondary scrambling code

Not Present

RBSB-354

– Spreading factor

128

RBSB-355

– Code number

96

RBSB-356

– Scrambling code change

No change

RBSB-357

– TPC combination index

0

RBSB-358

– SSDT Cell Identity

Not Present

R99 and Rel-4 only

RBSB-359

– Closed loop timing adjustment mode

Not Present

RBSB-360

– SCCPCH information for FACH

Not Present

R99 and Rel-4 only

RBSB-361

MBMS PL Service Restriction Information

Not Present

Rel-6

RBSB-362

Contents of RADIO BEARER SETUP message: AM or UM (E-DCH and HSDPA)

Information Element

Condition

Value/remark

Version

Index

Message Type

A1, A2, A3

RBSE-001

RRC transaction identifier

Arbitrarily selects an integer between 0 and 3

RBSE-002

Integrity check info

RBSE-003

– message authentication code

SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I.

RBSE-004

– RRC message sequence number

SS provides the value of this IE, from its internal counter.

RBSE-005

Integrity protection mode info

Not Present

RBSE-006

Ciphering mode info

Not Present

RBSE-007

Activation time

A1

Not Present

RBSE-008

Activation time

A2, A3

(256+CFN-(CFN MOD 8 + 8))MOD 256

RBSE-009

New U-RNTI

A1, A2, A3

Not Present

RBSE-010

New C-RNTI

Not Present

RBSE-011

New DSCH-RNTI

Not Present

R99 and Rel-4 only

RBSE-012

New H-RNTI

‘1010 1010 1010 1010’

Rel-5

RBSE-013

New Primary E-RNTI

‘1010 1010 1010 1010’

Rel-6

RBSE-014

New Secondary E-RNTI

Not Present

Rel-6

RBSE-015

RRC State indicator

CELL_DCH

RBSE-016

UTRAN DRX cycle length coefficient

Not Present

RBSE-017

CN information info

Not Present

RBSE-018

URA identity

Not Present

RBSE-019

CHOICE specification mode

Complete specification

Rel-6

RBSE-020

– Signalling RB information to setup

Not Present

RBSE-021

– RAB information for setup list

RBSE-022

– RAB information for setup

RBSE-023

– RAB info

(high-speed UM DTCH for PS domain)

RBSE-024

– RAB identity

0000 0110B

The first/ leftmost bit of the bit string contains the most significant bit of the RAB identity.

RBSE-025

– CN domain identity

PS domain

RBSE-026

– NAS Synchronization Indicator

Not Present

RBSE-027

– Re-establishment timer

useT315

RBSE-028

– RB information to setup

RBSE-029

– RB identity

25

RBSE-030

– PDCP info

Not present

RBSE-031

– CHOICE RLC info type

RLC info

RBSE-032

– CHOICE Uplink RLC mode

UM RLC

RBSE-033

– Transmission RLC discard

Not present

RBSE-034

– CHOICE Downlink RLC mode

UM RLC

RBSE-035

– DL UM RLC LI size

Selected with DL UM RLC data size

Rel-5

RBSE-036

– DL Reception Window Size

Not present

Rel-6

RBSE-037

– One sided RLC re-establishment

FALSE

RBSE-038

– Alternative E-bit interpretation

Not present

Rel-6

RBSE-039

– RB mapping info

RBSE-040

– Information for each multiplexing option

1 RBMuxOptions

RBSE-041

– RLC logical channel mapping indicator

Not Present

RBSE-042

– Number of uplink RLC logical channels

1

RBSE-043

– Uplink transport channel type

E-DCH

RBSE-044

– Logical channel identity

7

RBSE-045

– E-DCH MAC-d flow identity

2

RBSE-046

– DDI

5

RBSE-047

– RLC PDU size list

1 RLC PDU size

RBSE-048

– RLC PDU size

336 bits

RBSE-049

– Include in scheduling info

TRUE

RBSE-050

– MAC logical channel priority

8

RBSE-051

– Downlink RLC logical channel info

RBSE-052

– Number of downlink RLC logical channels

1

RBSE-053

– Downlink transport channel type

HS-DSCH

RBSE-054

– DL DCH Transport channel identity

Not Present

RBSE-055

– DL DSCH Transport channel identity

Not Present

RBSE-056

– CHOICE DL MAC header type

MAC-hs

Rel-7

RBSE-057

– DL HS-DSCH MAC-d flow identity

0

RBSE-058

– Logical channel identity

Not Present

RBSE-059

RB information to reconfigure list

Not Present

Rel-6

RBSE-060

RB information to be affected

A1

Not Present

RBSE-061

RB information to be affected

A2, A3

RBSE-062

– RB identity

1 (UM DCCH for RRC)

RBSE-063

– RB mapping info

RBSE-064

– Information for each multiplexing option

1 RBMuxOption

RBSE-065

– RLC logical channel mapping indicator

Not Present

RBSE-066

– Number of uplink RLC logical channels

1

RBSE-067

– Uplink transport channel type

E-DCH

RBSE-068

– Logical channel identity

1

RBSE-069

– E-DCH MAC-d flow identity

1

RBSE-070

– DDI

1

RBSE-071

– RLC PDU size list

1 RLC PDU size

RBSE-072

– RLC PDU size

96 bits

RBSE-073

– Include in scheduling info

FALSE

RBSE-074

– MAC logical channel priority

1

RBSE-075

– Downlink RLC logical channel info

RBSE-076

– Number of RLC logical channels

1

RBSE-077

– Downlink transport channel type

DCH

RBSE-078

– DL DCH Transport channel identity

10

RBSE-079

– DL DSCH Transport channel identity

Not Present

RBSE-080

– Logical channel identity

1

RBSE-081

– RB identity

2 (AM DCCH for RRC)

RBSE-082

– RB mapping info

RBSE-083

– Information for each multiplexing option

1 RBMuxOption

RBSE-084

– RLC logical channel mapping indicator

Not Present

RBSE-085

– Number of uplink RLC logical channels

1

RBSE-086

– Uplink transport channel type

E-DCH

RBSE-087

– Logical channel identity

2

RBSE-088

– E-DCH MAC-d flow identity

1

RBSE-089

– DDI

2

RBSE-090

– RLC PDU size list

1 RLC PDU size

RBSE-091

– RLC PDU size

96 bits

RBSE-092

– Include in scheduling info

FALSE

RBSE-093

– MAC logical channel priority

2

RBSE-094

– Downlink RLC logical channel info

RBSE-095

– Number of RLC logical channels

1

RBSE-096

– Downlink transport channel type

DCH

RBSE-097

– DL DCH Transport channel identity

10

RBSE-098

– DL DSCH Transport channel identity

Not Present

RBSE-099

– Logical channel identity

2

RBSE-100

– RB identity

3 (AM DCCH for NAS High Priority)

RBSE-101

– RB mapping info

RBSE-102

– Information for each multiplexing option

1 RBMuxOption

RBSE-103

– RLC logical channel mapping indicator

Not Present

RBSE-104

– Number of uplink RLC logical channels

1

RBSE-105

– Uplink transport channel type

E-DCH

RBSE-106

– Logical channel identity

3

RBSE-107

– E-DCH MAC-d flow identity

1

RBSE-108

– DDI

3

RBSE-109

– RLC PDU size list

1 RLC PDU size

RBSE-110

– RLC PDU size

96 bits

RBSE-111

– Include in scheduling info

FALSE

RBSE-112

– MAC logical channel priority

3

RBSE-113

– Downlink RLC logical channel info

RBSE-114

– Number of RLC logical channels

1

RBSE-115

– Downlink transport channel type

DCH

RBSE-116

– DL DCH Transport channel identity

10

RBSE-117

– DL DSCH Transport channel identity

Not Present

RBSE-118

– Logical channel identity

3

RBSE-119

– RB identity

4 (AM DCCH for NAS Low Priority)

RBSE-120

– RB mapping info

RBSE-121

– Information for each multiplexing option

1 RBMuxOption

RBSE-122

– RLC logical channel mapping indicator

Not Present

RBSE-123

– Number of uplink RLC logical channels

1

RBSE-124

– Uplink transport channel type

E-DCH

RBSE-125

– Logical channel identity

4

RBSE-126

– E-DCH MAC-d flow identity

1

RBSE-127

– DDI

4

RBSE-128

– RLC PDU size list

1 RLC PDU size

RBSE-129

– RLC PDU size

96 bits

RBSE-130

– Include in scheduling info

FALSE

RBSE-131

– MAC logical channel priority

4

RBSE-132

– Downlink RLC logical channel info

RBSE-133

– Number of RLC logical channels

1

RBSE-134

– Downlink transport channel type

DCH

RBSE-135

– DL DCH Transport channel identity

10

RBSE-136

– DL DSCH Transport channel identity

Not Present

RBSE-137

– Logical channel identity

4

RBSE-138

Downlink counter synchronization info

A1, A2, A3

Not Present

RBSE-139

PDCP ROHC target mode

Not Present

Rel-5

RBSE-140

UL Transport channel information for all transport channels

Not Present

RBSE-141

Deleted UL TrCH information

A1

Not Present

RBSE-142

Deleted UL TrCH information

A2, A3

RBSE-143

– Uplink transport channel type

DCH

RBSE-144

– UL transport channel identity

5

RBSE-145

Added or Reconfigured TrCH information list

A1

1 TrCH added

RBSE-146

– Added or Reconfigured UL TrCH information

1 E-DCH added

RBSE-147

– Uplink transport channel type

E-DCH

RBSE-148

– CHOICE UL parameters

E-DCH

RBSE-149

– E-DCH Transmission Time

Interval

10 ms

RBSE-150

– HARQ info for E-DCH

RBSE-151

– HARQ RV Configuration

Rv0

RBSE-152

– Added or reconfigured E-DCH

MAC-d flow

RBSE-153

– E-DCH MAC-d flow identity

2

RBSE-154

– E-DCH MAC-d flow power offset

0

RBSE-155

– E-DCH MAC-d flow maximum number of retransmissions

7

RBSE-156

– E-DCH MAC-d flow multiplexing list

Not Present

RBSE-157

– CHOICE transmission grant type

Scheduled grant info

RBSE-158

Added or Reconfigured UL TrCH information list

A2, A3

1 TrCH added

RBSE-159

– Added or Reconfigured UL TrCH information

1 E-DCH added with one DCCH MAC-d flow and one DTCH MAC-d flow

RBSE-160

– Uplink transport channel type

E-DCH

RBSE-161

– CHOICE UL parameters

E-DCH

RBSE-162

– E-DCH Transmission Time Interval

(A2: 2ms), (A3 10ms)

RBSE-163

– HARQ info for E-DCH

RBSE-164

– HARQ RV Configuration

Rv0

RBSE-165

– Added or reconfigured E-DCH MAC-d flow

(for DCCH)

RBSE-166

– E-DCH MAC-d flow identity

1

RBSE-167

– E-DCH MAC-d flow power offset

0

RBSE-168

– E-DCH MAC-d flow maximum number of retransmissions

7

RBSE-169

– E-DCH MAC-d flow multiplexing list

Not Present

RBSE-170

– CHOICE transmission grant type

Non-scheduled grant info

RBSE-171

– Max MAC-e PDU contents size

114 bits

RBSE-172

– 2 ms non-scheduled transmission grant HARQ process allocation

Not Present

RBSE-173

– Added or reconfigured E-DCH MAC-d flow

(for DTCH)

RBSE-174

– E-DCH MAC-d flow identity

2

RBSE-175

– E-DCH MAC-d flow power offset

0

RBSE-176

– E-DCH MAC-d flow maximum number of retransmissions

7

RBSE-177

– E-DCH MAC-d flow multiplexing list

Not Present

RBSE-178

– CHOICE transmission grant type

Scheduled grant info

RBSE-179

CHOICE mode

A1, A2, A3

Not Present

R99 and Rel-4 only

RBSE-180

DL Transport channel information common for all transport channels

A1, A3

Not Present

RBSE-181

DL Transport channel information common for all transport channels

A2

RBSE-182

– SCCPCH TFCS

Not Present

RBSE-183

– CHOICE mode

FDD

RBSE-184

– CHOICE DL parameters

Explicit

RBSE-185

– DL DCH TFCS

RBSE-186

– CHOICE TFCI Signalling

Normal

RBSE-187

– TFCI Field 1 Information

RBSE-188

– CHOICE TFCS representation

Complete reconfiguration

RBSE-189

– TFCS complete reconfigure

RBSE-190

– CHOICE CTFC Size

2 bit CTFC

RBSE-191

– CTFC information

2 TFCs

RBSE-192

– 2bit CTFC

0

RBSE-193

– Power offset Information

RBSE-194

– CHOICE Gain Factors

computedGainFactors

RBSE-195

– Reference TFC ID

0

RBSE-196

– Power offset Pp-m

Not Present

RBSE-197

– 2bit CTFC

1

RBSE-198

– Power offset Information

RBSE-199

– CHOICE Gain Factors

signalledGainFactors

RBSE-200

– CHOICE mode

FDD

RBSE-201

– Gain factor ßc

15

RBSE-202

– Gain factor ßd

15

RBSE-203

– Reference TFC ID

0

RBSE-204

– CHOICE mode

FDD

RBSE-205

– Power offset Pp-m

Not Present

RBSE-206

Deleted TrCH information list

A1, A2, A3

Not Present

RBSE-207

Added or Reconfigured TrCH information list

A1, A3

1 TrCH added

RBSE-208

– Added or Reconfigured DL TrCH information

HS-DSCH for DTCH added

RBSE-209

– Downlink transport channel type

HS-DSCH

RBSE-210

– DL Transport channel identity

Not Present

RBSE-211

– CHOICE DL parameters

HS-DSCH

RBSE-212

– HARQ Info

RBSE-213

– Number of Processes

Reference to TS34.121 [2] Annex C Fixed Reference Channels

RBSE-214

– CHOICE Memory Partitioning

Explicit

RBSE-215

– Memory size

Reference to TS34.121 [2] Annex C Fixed Reference Channels parameter “Number of HARQ Processes".

RBSE-216

– Process Memory Size

Reference to TS34.121 [2] Annex C Fixed Reference Channels parameter “Number of SML’s per HARQ Proc.”.

RBSE-217

– Additional memory sizes for MIMO

Not Present

Rel-7

RBSE-218

– CHOICE DL MAC header type

MAC-hs

Rel-7

RBSE-219

– Added or reconfigured MAC-d flow

RBSE-220

– MAC-hs queue to add or reconfigure list

(one queue)

RBSE-221

– MAC-hs queue Id

0

RBSE-222

– MAC-d Flow Identity

0

RBSE-223

– T1

50

RBSE-224

– MAC-hs window size

16

RBSE-225

– MAC-d PDU size Info

RBSE-226

– MAC-d PDU size

Reference to TS34.121 [2] Annex C Fixed Reference Channels

RBSE-227

– MAC-d PDU size index

0

RBSE-228

– MAC-hs queue to delete list

Not present

RBSE-229

– DCH quality target

Not present

RBSE-230

Added or Reconfigured DL TrCH information

A2

2 TrCHs (DCH for DCCH and HS-DSCH for DTCH)

RBSE-231

RBSE-232

– Downlink transport channel type

DCH

RBSE-233

– DL Transport channel identity

10

RBSE-234

– CHOICE DL parameters

Explicit

RBSE-235

– TFS

RBSE-236

– CHOICE Transport channel type

Dedicated transport channels

RBSE-237

– Dynamic Transport format information

RBSE-238

– RLC Size

96 bits

RBSE-239

– Number of TBs and TTI List

2

RBSE-240

– Transmission Time Interval

Not Present

RBSE-241

– Number of Transport blocks

0

RBSE-242

– Transmission Time Interval

Not Present

RBSE-243

– Number of Transport blocks

1

RBSE-244

– CHOICE Logical channel list

ALL

RBSE-245

– Semi-static Transport Format information

RBSE-246

– Transmission time interval

40

RBSE-247

– Type of channel coding

Convolutional

RBSE-248

– Coding Rate

1/3

RBSE-249

– Rate matching attribute

256

RBSE-250

– CRC size

12

RBSE-251

– DCH quality target

RBSE-252

– BLER Quality value

-20 (-2.0)

RBSE-253

– Downlink transport channel type

HS-DSCH

RBSE-254

– DL Transport channel identity

Not Present

RBSE-255

– CHOICE DL parameters

HS-DSCH

RBSE-256

– HARQ Info

RBSE-257

– Number of Processes

Reference to TS34.121 [2] Annex C Fixed Reference Channels

RBSE-258

– CHOICE Memory Partitioning

Explicit

RBSE-259

– Memory size

Reference to TS34.121 [2] Annex C Fixed Reference Channels parameter “Number of HARQ Processes".

RBSE-260

– Process Memory Size

Reference to TS34.121 [2] Annex C Fixed Reference Channels parameter “Number of SML’s per HARQ Proc.”.

RBSE-261

– Additional memory sizes for MIMO

Not Present

Rel-7

RBSE-262

– CHOICE DL MAC header type

MAC-hs

Rel-7

RBSE-263

– Added or reconfigured MAC-d flow

RBSE-264

– MAC-hs queue to add or reconfigure list

(one queue)

RBSE-265

– MAC-hs queue Id

0

RBSE-266

– MAC-d Flow Identity

0

RBSE-267

– T1

50

RBSE-268

– MAC-hs window size

16

RBSE-269

– MAC-d PDU size Info

RBSE-270

– MAC-d PDU size

Reference to TS34.121 [2] Annex C Fixed Reference Channels

RBSE-271

– MAC-d PDU size index

0

RBSE-272

– MAC-hs queue to delete list

Not present

RBSE-273

– DCH quality target

Not present

RBSE-274

Frequency info

A1, A2, A3

Not present

RBSE-275

Multi-frequency Info

Not present

Rel-7

RBSE-276

DTX-DRX timing information

Not present

Rel-7

RBSE-277

DRX Information

Not present

Rel-7

RBSE-278

HS-SCCH less Information

Not present

Rel-7

RBSE-279

MIMO parameters

Not present

Rel-7

RBSE-280

Maximum allowed UL TX power

33dBm

RBSE-281

CHOICE channel requirement

Uplink DPCH info

Rel-5 and earlier

RBSE-282

Uplink DPCH info

Rel-6

RBSE-283

– Uplink DPCH power control info

RBSE-284

– DPCCH power offset

-40 (-80dB)

RBSE-285

– PC Preamble

1 frame

RBSE-286

– SRB delay

7 frames

RBSE-287

– Power Control Algorithm

Algorithm1

RBSE-288

– TPC step size

0 (1dB)

RBSE-289

– ACK

3

RBSE-290

– NACK

3

RBSE-291

– Ack-Nack repetition factor

1

RBSE-292

– HARQ_preamble_mode

0

RBSE-293

– Scrambling code type

Long

RBSE-294

– Scrambling code number

0 (0 to 16777215)

RBSE-295

– Number of DPDCH

A1

Not Present(1)

RBSE-296

– spreading factor

Reference to clause 6.10 Parameter Set

RBSE-297

– TFCI existence

Reference to clause 6.10 Parameter Set

RBSE-298

– Number of FBI bit

Reference to clause 6.10 Parameter Set

RBSE-299

– Puncturing Limit

Reference to clause 6.10 Parameter Set

RBSE-300

– Number of DPDCH

A2, A3

0

RBSE-301

– spreading factor

Not present

RBSE-302

– TFCI existence

FALSE

RBSE-303

– Number of FBI bit

Not present

RBSE-304

– Puncturing Limit

Not present

RBSE-305

E-DCH info

A1, A2, A3

Rel-6

RBSE-306

– MAC-es/e reset indicator

TRUE

RBSE-307

– E-DPCCH info

RBSE-308

– E-DPCCH/DPCCH power offset

0

RBSE-309

– Happy bit delay condition

100 ms

RBSE-310

– E-TFCI boost info

Not present

Rel-7

RBSE-311

– E-TFCI BetaED SwitchE-DPDCH power interpolation

Not present

Rel-7

RBSE-312

– E-DPDCH info

A1, A3

RBSE-313

– E-TFCI table index

0

RBSE-314

– E-DCH minimum set E-TFCI

9

RBSE-315

– Reference E-TFCIs

1 E-TFCI

RBSE-316

– Reference E-TFCI

11

RBSE-317

– Reference E-TFCI PO

4

RBSE-318

– Maximum channelisation codes

2sf4

RBSE-319

– PLnon-max

0.84

RBSE-320

– Scheduling Information Configuration

RBSE-321

– Periodicity for Scheduling Info – no grant

Not present

RBSE-322

– Periodicity for Scheduling Info – grant

Not present

RBSE-323

– Power Offset for Scheduling Info

0

RBSE-324

– 3-Index-Step Threshold

Not present

RBSE-325

– 2-Index-Step Threshold

Not present

RBSE-326

– E-DPDCH info

A2

RBSE-327

– E-TFCI table index

0

RBSE-328

– E-DCH minimum set E-TFCI

9

RBSE-329

– Reference E-TFCIs

2 E-TFCI

RBSE-330

– Reference E-TFCI

11

RBSE-331

– Reference E-TFCI PO

4

RBSE-332

– Reference E-TFCI

83

RBSE-333

– Reference E-TFCI PO

16

RBSE-334

– Maximum channelisation codes

2sf2and2sf4

RBSE-335

– PLnon-max

0.84

RBSE-336

– Scheduling Information Configuration

RBSE-337

– Periodicity for Scheduling Info – no grant

Not present

RBSE-338

– Periodicity for Scheduling Info – grant

Not present

RBSE-339

– Power Offset for Scheduling Info

0

RBSE-340

– 3-Index-Step Threshold

Not present

RBSE-341

– 2-Index-Step Threshold

Not present

RBSE-342

– Scheduled Transmission configuration

A1, A2, A3

RBSE-343

– 2ms scheduled transmission grant HARQ process allocation

Not present

RBSE-344

– Serving Grant

Not present

RBSE-345

– UL 16QAM settings

Not present

Rel-7

RBSE-346

CHOICE Mode

FDD

R99 and Rel-4 only

RBSE-347

– Downlink PDSCH information

Not Present

R99 and Rel-4 only

RBSE-348

Downlink HS-PDSCH Information

RBSE-349

– HS-SCCH Info

RBSE-350

– CHOICE mode

FDD

RBSE-351

– DL Scrambling Code

Not present

RBSE-352

– HS-SCCH Channelisation Code Information

RBSE-353

– HS-SCCH Channelisation Code

2

RBSE-354

– HS-SCCH Channelisation Code

3

RBSE-355

– Measurement Feedback Info

RBSE-356

– CHOICE mode

FDD

RBSE-357

– POhsdsch

6 dB

RBSE-358

– CQI Feedback cycle, k

2 ms

RBSE-359

– CQI repetition factor

1

RBSE-360

– CQI

5 (corresponds to 0dB in relative power offset)

RBSE-361

– CHOICE mode

FDD

RBSE-362

– Downlink 64QAM configured

Not Present

Rel-7

RBSE-363

Downlink information common for all radio links

A1, A3

Not Present

RBSE-364

Downlink information common for all radio links

A2

RBSE-365

– Downlink DPCH info common for all RL

RBSE-366

– Timing indicator

Maintain

RBSE-367

– CFN-targetSFN frame offset

Not Present

RBSE-368

– Downlink DPCH power control information

RBSE-369

– DPC mode

0 (single)

RBSE-370

– CHOICE mode

FDD

RBSE-371

– Power offset PPilot-DPDCH

0

RBSE-372

– DL rate matching restriction information

Not Present

RBSE-373

– Spreading factor

256

RBSE-374

– Fixed or Flexible Position

Fixed

RBSE-375

– TFCI existence

FALSE

RBSE-376

– CHOICE SF

256

RBSE-377

– Number of bits for Pilot bits

8

RBSE-378

– CHOICE mode

FDD

RBSE-379

– DPCH compressed mode info

Not Present

RBSE-380

– TX Diversity mode

None

RBSE-381

– Default DPCH Offset Value

Not Present

RBSE-382

– MAC-hs reset indicator

Not Present

RBSE-383

– Post-verification period

Not Present

RBSE-384

Downlink information for each radio link list

A1, A2, A3

RBSE-385

– Downlink information for each radio link

RBSE-386

– Choice mode

FDD

RBSE-387

– Primary CPICH info

RBSE-388

– Primary scrambling code

Ref. to clause 6.1 "Default settings (FDD)"

RBSE-389

– PDSCH with SHO DCH info

Not Present

R99 and Rel-4 only

RBSE-390

– PDSCH code mapping

Not Present

R99 and Rel-4 only

RBSE-391

– Serving HS-DSCH radio link indicator

TRUE

RBSE-392

– Serving E-DCH radio link indicator

TRUE

RBSE-393

– Downlink DPCH info for each RL

RBSE-394

– CHOICE mode

FDD

RBSE-395

– Primary CPICH usage for channel estimation

Primary CPICH may be used

RBSE-396

– DPCH frame offset

Set to value Default DPCH Offset Value (as currently stored in SS) mod 38 400

RBSE-397

– Secondary CPICH info

Not Present

RBSE-398

– DL channelisation code

RBSE-399

– Secondary scrambling code

Not Present

RBSE-400

– Spreading factor

A1

Reference to clause 6.10 Parameter Set

RBSE-401

– Code number

96

RBSE-402

– Spreading factor

A2, A3

256

RBSE-403

– Code number

192

RBSE-404

– Scrambling code change

A1, A2, A3

No code change

RBSE-405

– TPC combination index

0

RBSE-406

– SSDT Cell Identity

Not Present

R99 and Rel-4 only

RBSE-407

– Closed loop timing adjustment mode

Not Present

RBSE-408

– E-AGCH Info

Rel-6

RBSE-409

– E-AGCH Channelisation Code

14

RBSE-410

– CHOICE E-HICH Information

Rel-6

RBSE-411

– E-HICH Information

RBSE-412

– DL Scrambling code

Not Present (default is primary)

RBSE-413

– Channelisation code

6

RBSE-414

– Signature sequence

1

RBSE-415

– CHOICE E-RGCH Information

Not Present

Rel-6

RBSE-416

– SCCPCH information for FACH

Not Present

R99 and Rel-4 only

RBSE-417

MBMS PL Service Restriction Information

Not Present

Rel-6

RBSE-418

Condition

Explanation

A1

Not using E-DCH 4codes except sub-test 5 in TS 34.121-1 [2] Table C.11.1.3

A2

Using E-DCH 4codes

A3

Sub-test 5 in TS 34.121-1 [2] Table C.11.1.3

Contents of RADIO BEARER SETUP message: AM or UM (HSDPA with F-DPCH)

Information Element

Value/remark

Version

Index

Message Type

 

Rel-6

RBSF-001

RRC transaction identifier

Arbitrarily selects an integer between 0 and 3

 

RBSF-002

Integrity check info

 

 

RBSF-003

– message authentication code

SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I.

 

RBSF-004

– RRC message sequence number

SS provides the value of this IE, from its internal counter.

 

RBSF-005

Integrity protection mode info

Not Present

 

RBSF-006

Ciphering mode info

Not Present

 

RBSF-007

Activation time

(256+CFN-(CFN MOD 8 + 8))MOD 256

RBSF-008

New U-RNTI

Not Present

Rel-6

RBSF-009

New C-RNTI

Not Present

Rel-6

RBSF-010

New H-RNTI

‘1010 1010 1010 1010’

Rel-6

RBSF-011

New Primary E-RNTI

Not Present

Rel-6

RBSF-012

New Secondary E-RNTI

Not Present

Rel-6

RBSF-013

RRC State indicator

CELL_DCH

Rel-6

RBSF-014

UTRAN DRX cycle length coefficient

Not Present

Rel-6

RBSF-015

CN information info

Not Present

 

RBSF-016

URA identity

Not Present

 

RBSF-017

CHOICE Specification mode

Complete specification

Rel-6

RBSF-018

– Signalling RB information to setup

Not Present

 

RBSF-019

– RAB information for setup

RBSF-020

– RAB info

(high-speed UM DTCH for PS domain)

RBSF-021

– RAB identity

0000 0110B

RBSF-022

– CN domain identity

PS domain

RBSF-023

– NAS Synchronization Indicator

Not Present

RBSF-024

– Re-establishment timer

useT315

RBSF-025

– RB information to setup

RBSF-026

– RB identity

25

RBSF-027

– PDCP info

Not Present

RBSF-028

– CHOICE RLC info type

RLC info

RBSF-029

– CHOICE Uplink RLC mode

Not present

RBSF-030

– CHOICE Downlink RLC mode

UM RLC

RBSF-031

– DL UM RLC LI size

Selected with DL UM RLC data size

Rel-5

RBSF-032

– One sided RLC re-establishment

FALSE

Rel-5

RBSF-033

– RB mapping info

RBSF-034

– Information for each multiplexing option

1 RBMuxOption

RBSF-035

– RLC logical channel mapping indicator

Not Present

RBSF-036

– Number of uplink RLC logical channels

1

RBSF-037

– Downlink RLC logical channel info

RBSF-038

– Number of downlink RLC logical channels

1

RBSF-039

– Downlink transport channel type

HS-DSCH

RBSF-040

– DL DCH Transport channel identity

Not present

RBSF-041

– DL DSCH Transport channel identity

Not present

RBSF-042

– CHOICE DL MAC header type

MAC-hs

Rel-7

RBSF-043

– DL HS-DSCH MAC-d flow identity

1

RBSF-044

– Logical channel identity

Not Present

RBSF-045

RB information to reconfigure list

Not Present

Rel-6

RBSF-046

RB information to be affected

Rel-6

RBSF-047

– RB identity

1 (UM DCCH for RRC)

RBSF-048

– RB mapping info

RBSF-049

– Information for each multiplexing option

1 RBMuxOption

RBSF-050

– RLC logical channel mapping indicator

Not Present

RBSF-051

– Number of uplink RLC logical channels

1

RBSF-052

– Uplink transport channel type

DCH

RBSF-053

– UL Transport channel identity

5

RBSF-054

– Logical channel identity

1

RBSF-055

– CHOICE RLC size list

Configured

RBSF-056

– MAC logical channel priority

1

RBSF-057

– Downlink RLC logical channel info

RBSF-058

– Number of RLC logical channels

1

RBSF-059

– Downlink transport channel type

HS-DSCH

RBSF-060

– DL DCH Transport channel identity

Not present

RBSF-061

– DL DSCH Transport channel identity

Not present

RBSF-062

– CHOICE DL MAC header type

MAC-hs

Rel-7

RBSF-063

– DL HS-DSCH MAC-d flow identity

0

RBSF-064

– Logical channel identity

1

RBSF-065

– RB identity

2 (AM DCCH for RRC)

RBSF-066

– RB mapping info

RBSF-067

– Information for each multiplexing option

1 RBMuxOption

RBSF-068

– RLC logical channel mapping indicator

Not Present

RBSF-069

– Number of uplink RLC logical channels

1

RBSF-070

– Uplink transport channel type

DCH

RBSF-071

– UL Transport channel identity

5

RBSF-072

– Logical channel identity

2

RBSF-073

– CHOICE RLC size list

Configured

RBSF-074

– MAC logical channel priority

2

RBSF-075

– Downlink RLC logical channel info

RBSF-076

– Number of RLC logical channels

1

RBSF-077

– Downlink transport channel type

HS-DSCH

RBSF-078

– DL DCH Transport channel identity

Not Present

RBSF-079

– DL DSCH Transport channel identity

Not Present

RBSF-080

– CHOICE DL MAC header type

MAC-hs

Rel-7

RBSF-081

– DL HS-DSCH MAC-d flow identity

0

RBSF-082

– Logical channel identity

2

RBSF-083

– RB identity

3 (AM DCCH for NAS High Priority)

RBSF-084

– RB mapping info

RBSF-085

– Information for each multiplexing option

1 RBMuxOption

RBSF-086

– RLC logical channel mapping indicator

Not Present

RBSF-087

– Number of uplink RLC logical channels

1

RBSF-088

– Uplink transport channel type

DCH

RBSF-089

– UL Transport channel identity

5

RBSF-090

– Logical channel identity

3

RBSF-091

– CHOICE RLC size list

Configured

RBSF-092

– MAC logical channel priority

3

RBSF-093

– Downlink RLC logical channel info

RBSF-094

– Number of RLC logical channels

1

RBSF-095

– Downlink transport channel type

HS-DSCH

RBSF-096

– DL DCH Transport channel identity

Not Present

RBSF-097

– DL DSCH Transport channel identity

Not Present

RBSF-098

– CHOICE DL MAC header type

MAC-hs

Rel-7

RBSF-099

– DL HS-DSCH MAC-d flow identity

0

RBSF-100

– Logical channel identity

3

RBSF-101

– RB identity

4 (AM DCCH for NAS Low Priority)

RBSF-102

– RB mapping info

RBSF-103

– Information for each multiplexing option

1 RBMuxOption

RBSF-104

– RLC logical channel mapping indicator

Not Present

RBSF-105

– Number of uplink RLC logical channels

1

RBSF-106

– Uplink transport channel type

DCH

RBSF-107

– UL Transport channel identity

5

RBSF-108

– Logical channel identity

4

RBSF-109

– CHOICE RLC size list

Configured

RBSF-110

– MAC logical channel priority

4

RBSF-111

– Downlink RLC logical channel info

RBSF-112

– Number of RLC logical channels

1

RBSF-113

– Downlink transport channel type

HS-DSCH

RBSF-114

– DL DCH Transport channel identity

Not Present

RBSF-115

– DL DSCH Transport channel identity

Not Present

RBSF-116

– CHOICE DL MAC header type

MAC-hs

Rel-7

RBSF-117

– DL HS-DSCH MAC-d flow identity

0

RBSF-118

– Logical channel identity

4

RBSF-119

Downlink counter synchronization info

Not Present

Rel-6

RBSF-120

PDCP ROHC target mode

Not Present

Rel-6

RBSF-121

UL Transport channel information for all transport channels

Rel-6

RBSF-122

– PRACH TFCS

Not Present

RBSF-123

– CHOICE Mode

FDD

RBSF-124

– TFC subset

Not Present

RBSF-125

– UL DCH TFCS

RBSF-126

– CHOICE TFCI signalling

Normal

RBSF-127

– TFCI Field 1 information

RBSF-128

– CHOICE TFCS representation

Complete reconfiguration

RBSF-129

– TFCS complete reconfiguration information

RBSF-130

– CHOICE CTFC Size

2 bit CTFC

RBSF-131

– CTFC information

2 TFCs

RBSF-132

– 2bit CTFC

0

RBSF-133

– Power offset Information

RBSF-134

– CHOICE Gain Factors

computedGainFactors

RBSF-135

– Reference TFC ID

0

RBSF-136

– CHOICE mode

FDD

RBSF-137

– Power offset Pp-m

Not Present

RBSF-138

– 2bit CTFC

1

RBSF-139

– Power offset Information

RBSF-140

– CHOICE Gain Factors

signalledGainFactors

RBSF-141

– CHOICE mode

FDD

RBSF-142

– Gain factor ßc

15

RBSF-143

– Gain factor ßd

15

RBSF-144

– Reference TFC ID

0

RBSF-145

– CHOICE mode

FDD

RBSF-146

– Power offset Pp-m

Not Present

RBSF-147

Deleted UL TrCH information

Not Present

Rel-6

RBSF-148

Added or Reconfigured UL TrCH information

Rel-6

RBSF-149

– Added or Reconfigured UL TrCH information

RBSF-150

– Uplink transport channel type

DCH

RBSF-151

– UL Transport channel identity

5

RBSF-152

– TFS

RBSF-153

– CHOICE Transport channel type

Dedicated transport channels

RBSF-154

– Dynamic Transport Format Information

RBSF-155

– RLC size

96 bits

RBSF-156

– Number of TBs and TTI List

2

RBSF-157

– Transmission Time Interval

Not Present

RBSF-158

– Number of Transport blocks

0

RBSF-159

– Transmission Time Interval

Not Present

RBSF-160

– Number of Transport blocks

1

RBSF-161

– CHOICE Logical channel List

ALL

RBSF-162

– Semi-static Transport Format Information

RBSF-163

– Transmission time interval

40

RBSF-164

– Type of channel coding

Convolutional

RBSF-165

– Coding Rate

1/3

RBSF-166

– Rate matching attribute

256

RBSF-167

– CRC size

12

RBSF-168

DL Transport channel information common for all transport channel

Not Present

Rel-6

RBSF-169

Deleted DL TrCH information

Rel-6

RBSF-170

– Downlink transport channel type

DCH

RBSF-171

– DL Transport channel identity

10

RBSF-172

Added or Reconfigured DL TrCH information

1 TrCH (HS-DSCH for DTCH and DCCH)

Rel-6

RBSF-173

– Downlink transport channel type

HS-DSCH

RBSF-174

– DL Transport channel identity

Not Present

RBSF-175

– CHOICE DL parameters

HS-DSCH

RBSF-176

– HARQ Info

RBSF-177

– Number of Processes

Reference to TS34.121 [2] Annex C Fixed Reference Channels

RBSF-178

– CHOICE Memory Partitioning

Explicit

RBSF-179

– Memory size

Reference to TS34.121 [2] Annex C Fixed Reference Channels parameter “Number of HARQ Processes”.

RBSF-180

– Process Memory Size

Reference to TS34.121 [2] Annex C Fixed Reference Channels parameter “Number of SML’s per HARQ Proc.”.

RBSF-181

– Additional memory sizes for MIMO

Not Present

Rel-7

RBSF-182

– CHOICE DL MAC header type

MAC-hs

Rel-7

RBSF-183

– Added or reconfigured MAC-d flow

RBSF-184

– MAC-hs queue to add or reconfigure list

(two queues)

RBSF-185

– MAC-hs queue Id

0 (for DCCH)

RBSF-186

– MAC-d Flow Identity

0

RBSF-187

– T1

50

RBSF-188

– MAC-hs window size

16

RBSF-189

– MAC-d PDU size Info

RBSF-190

– MAC-d PDU size

100

RBSF-191

– MAC-d PDU size index

0

RBSF-192

– MAC-hs queue Id

1 (for DTCH)

RBSF-193

– MAC-d Flow Identity

1

RBSF-194

– T1

50

RBSF-195

– MAC-hs window size

16

RBSF-196

– MAC-d PDU size Info

RBSF-197

– MAC-d PDU size

Reference to TS34.121 [2] Annex C Fixed Reference Channels

RBSF-198

– MAC-d PDU size index

0

RBSF-199

– MAC-hs queue to delete list

Not present

RBSF-200

– DCH quality target

Not present

RBSF-201

Frequency info

Not present

RBSF-202

Multi-frequency Info

Not present

Rel-7

RBSF-203

DTX-DRX timing information

Not present

Rel-7

RBSF-204

DRX Information

Not present

Rel-7

RBSF-205

HS-SCCH less Information

Not present

Rel-7

RBSF-206

MIMO parameters

Not present

Rel-7

RBSF-207

Maximum allowed UL TX power

33dBm

RBSF-208

Uplink DPCH info

Rel-6

RBSF-209

– Uplink DPCH power control info

RBSF-210

– DPCCH power offset

-40 (-80dB)

RBSF-211

– PC Preamble

1 frame

RBSF-212

– SRB delay

7 frames

RBSF-213

– Power Control Algorithm

Algorithm1

RBSF-214

– TPC step size

0 (1dB)

RBSF-215

– ACK

3

RBSF-216

– NACK

3

RBSF-217

– Ack-Nack repetition factor

1

RBSF-218

– HARQ_preamble_mode

0

RBSF-219

– CHOICE mode

FDD

RBSF-220

– Scrambling code type

Long

RBSF-221

– Scrambling code number

0 (0 to 16777215)

RBSF-222

– Number of DPDCH

Not Present (1)

RBSF-223

– spreading factor

256

RBSF-224

– TFCI existence

TRUE

RBSF-225

– Number of FBI bit

Not Present(0)

RBSF-226

– Puncturing Limit

1

RBSF-227

E-DCH info

Not Present

Rel-6

RBSF-228

Downlink HS-PDSCH Information

Rel-6

RBSF-229

– HS-SCCH Info

RBSF-230

– CHOICE mode

FDD

RBSF-231

– DL Scrambling Code

Not present

RBSF-232

– HS-SCCH Channelisation Code Information

RBSF-233

– HS-SCCH Channelisation Code

2

RBSF-234

– Measurement Feedback Info

RBSF-235

– CHOICE mode

FDD

RBSF-236

– POhsdsch

6 dB

RBSF-237

– CQI Feedback cycle, k

2 ms

RBSF-238

– CQI repetition factor

1

RBSF-239

– CQI

5 (corresponds to 0dB in relative power offset)

RBSF-240

– CHOICE mode

FDD

RBSF-241

– Downlink 64QAM configured

Not Present

Rel-7

RBSF-242

Downlink information common for all radio links

Rel-6

RBSF-243

– Downlink F-DPCH info common for all RL

RBSF-244

– Timing Indication

Maintain

RBSF-245

– Timing maintained Synchronization indicator

FALSE

RBSF-246

– Downlink F-DPCH power control information

RBSF-247

– DPC mode

0 (single)

RBSF-248

– TPC command error rate target

0.04

RBSF-249

– CHOICE mode

FDD

RBSF-250

– DPCH compressed mode info

Not Present

RBSF-251

– TX Diversity mode

None

RBSF-252

– Default DPCH Offset Value

Not Present

RBSF-253

– MAC-hs reset indicator

Not Present

RBSF-254

Downlink information for each radio link list

Rel-6

RBSF-255

– Downlink information for each radio link

RBSF-256

– Choice mode

FDD

RBSF-257

– Primary CPICH info

RBSF-258

– Primary scrambling code

Ref. to clause 6.1 "Default settings (FDD)"

RBSF-259

– Serving HS-DSCH radio link indicator

TRUE

RBSF-260

– Downlink DPCH info for each RL

Not Present

RBSF-261

– Downlink F-DPCH info for each RL

RBSF-262

– Primary CPICH usage for channel estimation

Primary CPICH may be used

RBSF-263

– F-DPCH frame offset

Set to value Default DPCH Offset Value (as currently stored in SS) mod 38 400

RBSF-264

– Secondary CPICH info

Not Present

RBSF-265

– Secondary scrambling code

Not Present

RBSF-266

– Code number

6

RBSF-267

– TPC combination index

0

RBSF-268

MBMS PL Service Restriction Information

Not Present

Rel-6

RBSF-269

Contents of RADIO BEARER SETUP message: AM or UM (DC-HSDPA)

Information Element

Value/remark

Version

Index

Message Type

RBSD-001

RRC transaction identifier

Arbitrarily selects an integer between 0 and 3

RBSD-002

Integrity check info

RBSD-003

– message authentication code

SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I.

RBSD-004

– RRC message sequence number

SS provides the value of this IE, from its internal counter.

RBSD-005

Integrity protection mode info

Not Present

RBSD-006

Ciphering mode info

Not Present

RBSD-007

Activation time

Not Present

RBSD-008

New U-RNTI

Not Present

RBSD-009

New C-RNTI

Not Present

RBSD-010

New H-RNTI

‘1010 1010 1010 1010’

Rel-5

RBSD-011

New Primary E-RNTI

Not Present

Rel-6

RBSD-012

New Secondary E-RNTI

Not Present

Rel-6

RBSD-013

RRC State indicator

CELL_DCH

RBSD-014

UTRAN DRX cycle length coefficient

Not Present

RBSD-015

CN information info

Not Present

RBSD-016

URA identity

Not Present

RBSD-017

CHOICE specification mode

Complete specification

Rel-6

RBSD-018

Signalling RB information to setup

Not Present

RBSD-019

RAB information for setup list

RBSD-020

– RAB information for setup

RBSD-021

– RAB info

(high-speed UM DTCH for PS domain)

RBSD-022

– RAB identity

0000 0110B

The first/ leftmost bit of the bit string contains the most significant bit of the RAB identity.

RBSD-023

– CN domain identity

PS domain

RBSD-024

– NAS Synchronization Indicator

Not Present

RBSD-025

– Re-establishment timer

UseT315

RBSD-026

– RB information to setup

RBSD-027

– RB identity

25

RBSD-028

– PDCP info

Not Present

RBSD-029

– CHOICE RLC info type

RLC info

RBSD-030

– CHOICE Uplink RLC mode

Not Present

RBSD-031

– CHOICE Downlink RLC mode

UM RLC

RBSD-032

– DL UM RLC LI size

Selected with DL UM RLC data size

Rel-5

RBSD-033

– One sided RLC re-establishment

FALSE

Rel-5

RBSD-034

– RB mapping info

RBSD-035

– Information for each multiplexing option

1 RBMuxOptions

RBSD-036

– RLC logical channel mapping indicator

Not Present

RBSD-037

– Downlink RLC logical channel info

RBSD-038

– Number of downlink RLC logical channels

1

RBSD-039

– Downlink transport channel type

HS-DSCH

RBSD-040

– DL DCH Transport channel identity

Not Present

RBSD-041

– DL DSCH Transport channel identity

Not Present

RBSD-042

– CHOICE DL MAC header type

MAC-ehs

Rel-7

RBSD-043

– DL HS-DSCH MAC-ehs Queue Id

0

RBSD-044

– Logical channel identity

1

RBSD-045

RB information to reconfigure list

Not Present

Rel-6

RBSD-046

RB information to be affected list

Not Present

RBSD-047

Downlink counter synchronization info

Not Present

RBSD-048

PDCP ROHC target mode

Not Present

Rel-5

RBSD-049

UL Transport channel information for all transport channels

RBSD-050

– PRACH TFCS

Not Present

RBSD-051

– CHOICE mode

FDD

RBSD-052

– TFC subset

Not Present

RBSD-053

– UL DCH TFCS

RBSD-054

– CHOICE TFCI signalling

Normal

RBSD-055

– TFCI Field 1 information

RBSD-056

– CHOICE TFCS representation

Complete reconfiguration

RBSD-057

– TFCS complete reconfigure information

RBSD-058

– CHOICE CTFC Size

2 bit CTFC

RBSD-059

– CTFC information

4 TFCs

RBSD-060

– CTFC

Reference to clause TS 34.121 clause C.2.1 Parameter Set

RBSD-061

– Power offset information

RBSD-062

– CHOICE Gain Factors

Computed Gain Factors(The last TFC is set to Signalled Gain Factors)

RBSD-063

– Gain factor βc

8

(Not Present if the CHOICE Gain Factors is set to Computed Gain Factors)

RBSD-064

– Gain factor βd

15

(Not Present if the CHOICE Gain Factors is set to Computed Gain Factors)

RBSD-065

– Reference TFC ID

0

RBSD-066

– CHOICE mode

FDD

RBSD-067

– Power offset P p-m

Not Present

RBSD-068

Deleted UL TrCH information list

Not Present

RBSD-069

Added or Reconfigured TrCH information list

Not Present

RBSD-070

CHOICE mode

Not Present

RBSD-071

DL Transport channel information common for all transport channel

RBSD-072

– SCCPCH TFCS

Not Present

RBSD-073

– CHOICE mode

FDD

RBSD-074

– CHOICE DL parameters

Explicit

RBSD-075

– DL DCH TFCS

RBSD-076

– CHOICE TFCI Signalling

Normal

RBSD-077

– TFCI Field 1 Information

RBSD-078

– CHOICE TFCS representation

Complete reconfiguration

RBSD-079

– TFCS complete reconfigure

RBSD-080

– CHOICE CTFC Size

2 bit CTFC

RBSD-081

– CTFC information

4 TFCs

RBSD-082

– CTFC

Reference to clause TS 34.121 clause C.3.1 Parameter Set

RBSD-083

– Power offset information

Not Present

RBSD-084

Deleted DL TrCH information

Not Present

RBSD-085

Added or Reconfigured DL TrCH information list

1 TrCHs added

RBSD-086

– Added or Reconfigured DL TrCH information

(HS-DSCH for DTCH)

RBSD-087

– Downlink transport channel type

HS-DSCH

Rel-5

RBSD-088

– DL Transport channel identity

Not Present

RBSD-089

– CHOICE DL parameters

HS-DSCH

RBSD-090

– HARQ Info

Rel-5

RBSD-091

– Number of Processes

Reference to TS34.121 [2] Annex C Fixed Reference Channels

RBSD-092

– CHOICE Memory Partitioning

Explicit

RBSD-093

– Memory size

Reference to TS34.121 [2] Annex C Fixed Reference Channels parameter “Number of HARQ Processes”.

RBSD-094

– Process Memory Size

Reference to TS34.121 [2] Annex C Fixed Reference Channels parameter “Number of SML’s per HARQ Proc.”.

RBSD-095

– Additional memory sizes for MIMO

Not Present

Rel-7

RBSD-096

– CHOICE DL MAC header type

MAC-ehs

Rel-7

RBSD-097

– Added or reconfigured MAC-ehs reordering queue

RBSD-098

– MAC-ehs queue to add or reconfigure list

(one queue)

Rel-7

RBSD-099

– MAC-ehs queue Id

0

RBSD-100

– T1

50

RBSD-101

– Treset

Not Present

RBSD-102

– MAC-ehs window size

32

RBSD-103

– DCH quality target

Not present

RBSD-108

Frequency info

Not Present

RBSD-109

Multi-frequency Info

Not present

Rel-7

RBSD-110

DTX-DRX timing information

Not present

Rel-7

RBSD-111

DRX Information

Not present

Rel-7

RBSD-112

HS-SCCH less Information

Not present

Rel-7

RBSD-113

MIMO parameters

Not present

Rel-7

RBSD-114

Maximum allowed UL TX power

33dBm

RBSD-115

CHOICE channel requirement

Uplink DPCH info

Rel-5 and earlier

RBSD-116

Uplink DPCH info

Rel-6

RBSD-117

– Uplink DPCH power control info

RBSD-118

– CHOICE mode

FDD

RBSD-119

– DPCCH power offset

-40 (-80dB) IE value will have no effect on the UE UL power when closed loop power control is active

RBSD-120

– PC Preamble

1 frame

RBSD-121

– SRB delay

7 frames

RBSD-122

– Power Control Algorithm

Algorithm1

RBSD-123

– TPC step size

0 (1dB)

RBSD-124

– ACK

3

Rel-5

RBSD-125

– NACK

3

Rel-5

RBSD-126

– Ack-Nack repetition factor

1

Rel-5

RBSD-127

– CHOICE mode

FDD

RBSD-128

– Scrambling code type

Long

RBSD-129

– Scrambling code number

0 (0 to 16777215)

RBSD-130

– Number of DPDCH

Not Present (1)

RBSD-131

– spreading factor

64

RBSD-132

– TFCI existence

TRUE

RBSD-133

– Number of FBI bit

Not Present(0)

RBSD-134

– Puncturing Limit

1

RBSD-135

E-DCH Info

Not Present

Rel-6

RBSD-136

Downlink HS-PDSCH Information

RBSD-137

– HS-SCCH Info

RBSD-138

– CHOICE mode

FDD

RBSD-139

– DL Scrambling Code

RBSD-140

– HS-SCCH Channelisation Code Information

RBSD-141

– HS-SCCH Channelisation Code

2

RBSD-142

– HS-SCCH Channelisation Code

3

RBSD-143

– Measurement Feedback Info

RBSD-146

– CHOICE mode

FDD

RBSD-147

– Measurement Power Offset

6 dB

Rel-5

RBSD-148

– CQI Feedback cycle, k

2 ms

Rel-5

RBSD-149

– CQI repetition factor

1

Rel-5

RBSD-150

– CQI

5 (corresponds to 0dB in relative power offset)

Rel-5

RBSD-151

– CHOICE mode

FDD

RBSD-152

– Downlink 64QAM configured

Not Present

Rel-7

RBSD-153

– HS-DSCH TB size table

Not Present

Rel-7

RBSD-153b

Downlink information common for all radio links

Not Present

RBSD-154

Downlink information per radio link list

RBSD-155

– Downlink information for each radio link

RBSD-156

– CHOICE mode

FDD

RBSD-157

– Primary CPICH info

RBSD-158

– Primary scrambling code

Reference to clause 6.1 "Default settings (FDD)"

RBSD-159

– Serving HS-DSCH radio link indicator

TRUE

Rel-5

RBSD-160

– Downlink DPCH info for each RL

RBSD-161

– CHOICE mode

FDD

RBSD-162

– Primary CPICH usage for channel estimation

Primary CPICH may be used

RBSD-163

– DPCH frame offset

Set to value Default DPCH Offset Value (as currently stored in SS) mod 38 400

RBSD-164

– Secondary CPICH info

Not Present

RBSD-165

– DL channelisation code

RBSD-166

– Secondary scrambling code

Not present

RBSD-167

– Spreading factor

128

RBSD-168

– Code number

96

RBSD-169

– Scrambling code change

No change

RBSD-170

– TPC combination index

0

RBSD-171

– Closed loop timing adjustment mode

Not Present

RBSD-172

Downlink secondary cell info FDD

Rel-8

RBSD-173

– CHOICE Configuration info

New configuration

RBSD-174

– New H-RNTI

‘1010 1010 1010 1010’

RBSD-175

– Downlink 64QAM configured

Not Present

RBSD-176

– HS-DSCH TB size table

Not Present

RBSD-177

– Primary CPICH info

RBSD-178

– Primary scrambling code

Ref. to the Default setting in clause 6.1 (FDD)

RBSD-179

– DL Scrambling Code

Not Present

RBSD-180

– HS-SCCH Channelisation Code Information

RBSD-181

– HS-SCCH Channelisation Code

2

RBSD-182

– HS-SCCH Channelisation Code

3

RBSD-183

– Measurement Power Offset

6 dB

RBSD-184

– UARFCN downlink (Nd)

Reference to clause 5.1 Test frequencies

RBSD-185

MBMS PL Service Restriction Information

Not Present

Rel-6

RBSD-186

Contents of RADIO BEARER SETUP message: AM or UM (DC-HSUPA)

Information Element

Condition

Value/remark

Version

Index

Message Type

RBSE-001

RRC transaction identifier

Arbitrarily selects an integer between 0 and 3

RBSE-002

Integrity check info

RBSE-003

– message authentication code

SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I.

RBSE-004

– RRC message sequence number

SS provides the value of this IE, from its internal counter.

RBSE-005

Integrity protection mode info

Not Present

RBSE-006

Ciphering mode info

Not Present

RBSE-007

New U-RNTI

Not Present

RBSE-008

New C-RNTI

Not Present

RBSE-009

New DSCH-RNTI

Not Present

R99 and Rel-4 only

RBSE-010

New H-RNTI

‘1010 1010 1010 1010’

Rel-5

RBSE-011

New Primary E-RNTI

‘1010 1010 1010 1010’

Rel-6

RBSE-012

New Secondary E-RNTI

Not Present

Rel-6

RBSE-013

RRC State indicator

CELL_DCH

RBSE-014

UTRAN DRX cycle length coefficient

Not Present

RBSE-015

CN information info

Not Present

RBSE-016

URA identity

Not Present

RBSE-017

CHOICE specification mode

Complete specification

Rel-6

RBSE-018

– Signalling RB information to setup

Not Present

RBSE-019

– RAB information for setup list

RBSE-020

– RAB information for setup

RBSE-021

– RAB info

(high-speed UM DTCH for PS domain)

RBSE-022

– RAB identity

0000 0110B

The first/ leftmost bit of the bit string contains the most significant bit of the RAB identity.

RBSE-023

– CN domain identity

PS domain

RBSE-024

– NAS Synchronization Indicator

Not Present

RBSE-025

– Re-establishment timer

useT315

RBSE-026

– RB information to setup

RBSE-027

– RB identity

25

RBSE-028

– PDCP info

Not present

RBSE-029

– CHOICE RLC info type

RLC info

RBSE-030

– CHOICE Uplink RLC mode

UM RLC

RBSE-031

– Transmission RLC discard

Not present

RBSE-032

– CHOICE Downlink RLC mode

UM RLC

RBSE-033

– DL UM RLC LI size

Selected with DL UM RLC data size

Rel-5

RBSE-034

– DL Reception Window Size

Not present

Rel-6

RBSE-035

– One sided RLC re-establishment

FALSE

RBSE-036

– Alternative E-bit interpretation

Not present

Rel-6

RBSE-037

– RB mapping info

RBSE-038

– Information for each multiplexing option

1 RBMuxOptions

RBSE-039

– RLC logical channel mapping indicator

Not Present

RBSE-040

– Number of uplink RLC logical channels

1

RBSE-041

– Uplink transport channel type

E-DCH

RBSE-042

– Logical channel identity

7

RBSE-043

– E-DCH MAC-d flow identity

2

RBSE-044

– DDI

5

RBSE-045

– RLC PDU size list

1 RLC PDU size

RBSE-046

– RLC PDU size

336 bits

RBSE-047

– Include in scheduling info

TRUE

RBSE-048

– MAC logical channel priority

8

RBSE-049

– Downlink RLC logical channel info

RBSE-050

– Number of downlink RLC logical channels

1

RBSE-051

– Downlink transport channel type

HS-DSCH

RBSE-052

– DL DCH Transport channel identity

Not Present

RBSE-053

– DL DSCH Transport channel identity

Not Present

RBSE-054

– CHOICE DL MAC header type

MAC-ehs

Rel-7

RBSE-055

– DL HS-DSCH MAC-d flow identity

0

RBSE-056

– Logical channel identity

Not Present

RBSE-057

RB information to reconfigure list

Not Present

Rel-6

RBSE-058

RB information to be affected

RBSE-059

– RB identity

1 (UM DCCH for RRC)

RBSE-060

– RB mapping info

RBSE-061

– Information for each multiplexing option

1 RBMuxOption

RBSE-062

– RLC logical channel mapping indicator

Not Present

RBSE-063

– Number of uplink RLC logical channels

1

RBSE-064

– Uplink transport channel type

E-DCH

RBSE-065

– Logical channel identity

1

RBSE-066

– E-DCH MAC-d flow identity

1

RBSE-067

– DDI

1

RBSE-068

– RLC PDU size list

1 RLC PDU size

RBSE-069

– RLC PDU size

96 bits

RBSE-070

– Include in scheduling info

FALSE

RBSE-071

– MAC logical channel priority

1

RBSE-072

– Downlink RLC logical channel info

RBSE-073

– Number of RLC logical channels

1

RBSE-074

– Downlink transport channel type

DCH

RBSE-075

– DL DCH Transport channel identity

10

RBSE-076

– DL DSCH Transport channel identity

Not Present

RBSE-077

– Logical channel identity

1

RBSE-078

– RB identity

2 (AM DCCH for RRC)

RBSE-079

– RB mapping info

RBSE-080

– Information for each multiplexing option

1 RBMuxOption

RBSE-081

– RLC logical channel mapping indicator

Not Present

RBSE-082

– Number of uplink RLC logical channels

1

RBSE-083

– Uplink transport channel type

E-DCH

RBSE-084

– Logical channel identity

2

RBSE-085

– E-DCH MAC-d flow identity

1

RBSE-086

– DDI

2

RBSE-087

– RLC PDU size list

1 RLC PDU size

RBSE-088

– RLC PDU size

96 bits

RBSE-089

– Include in scheduling info

FALSE

RBSE-090

– MAC logical channel priority

2

RBSE-091

– Downlink RLC logical channel info

RBSE-092

– Number of RLC logical channels

1

RBSE-093

– Downlink transport channel type

DCH

RBSE-094

– DL DCH Transport channel identity

10

RBSE-095

– DL DSCH Transport channel identity

Not Present

RBSE-096

– Logical channel identity

2

RBSE-097

– RB identity

3 (AM DCCH for NAS High Priority)

RBSE-098

– RB mapping info

RBSE-099

– Information for each multiplexing option

1 RBMuxOption

RBSE-100

– RLC logical channel mapping indicator

Not Present

RBSE-101

– Number of uplink RLC logical channels

1

RBSE-102

– Uplink transport channel type

E-DCH

RBSE-103

– Logical channel identity

3

RBSE-104

– E-DCH MAC-d flow identity

1

RBSE-105

– DDI

3

RBSE-106

– RLC PDU size list

1 RLC PDU size

RBSE-107

– RLC PDU size

96 bits

RBSE-108

– Include in scheduling info

FALSE

RBSE-109

– MAC logical channel priority

3

RBSE-110

– Downlink RLC logical channel info

RBSE-111

– Number of RLC logical channels

1

RBSE-112

– Downlink transport channel type

DCH

RBSE-113

– DL DCH Transport channel identity

10

RBSE-114

– DL DSCH Transport channel identity

Not Present

RBSE-115

– Logical channel identity

3

RBSE-116

– RB identity

4 (AM DCCH for NAS Low Priority)

RBSE-117

– RB mapping info

RBSE-118

– Information for each multiplexing option

1 RBMuxOption

RBSE-119

– RLC logical channel mapping indicator

Not Present

RBSE-120

– Number of uplink RLC logical channels

1

RBSE-121

– Uplink transport channel type

E-DCH

RBSE-122

– Logical channel identity

4

RBSE-123

– E-DCH MAC-d flow identity

1

RBSE-124

– DDI

4

RBSE-125

– RLC PDU size list

1 RLC PDU size

RBSE-126

– RLC PDU size

96 bits

RBSE-127

– Include in scheduling info

FALSE

RBSE-128

– MAC logical channel priority

4

RBSE-129

– Downlink RLC logical channel info

RBSE-130

– Number of RLC logical channels

1

RBSE-131

– Downlink transport channel type

DCH

RBSE-132

– DL DCH Transport channel identity

10

RBSE-133

– DL DSCH Transport channel identity

Not Present

RBSE-134

– Logical channel identity

4

RBSE-135

Downlink counter synchronization info

Not Present

RBSE-136

PDCP ROHC target mode

Not Present

Rel-5

RBSE-137

UL Transport channel information for all transport channels

Not Present

RBSE-138

Deleted UL TrCH information

RBSE-139

– Uplink transport channel type

DCH

RBSE-140

– UL transport channel identity

5

RBSE-141

Added or Reconfigured UL TrCH information list

1 TrCH added

RBSE-142

– Added or Reconfigured UL TrCH information

1 E-DCH added with one DCCH MAC-d flow and one DTCH MAC-d flow

RBSE-143

– Uplink transport channel type

E-DCH

RBSE-144

– CHOICE UL parameters

E-DCH

RBSE-145

– UL MAC header type

MAC-i/is

Rel-8

RBSE-145a

– E-DCH Transmission Time Interval

2ms

RBSE-146

– HARQ info for E-DCH

RBSE-147

– HARQ RV Configuration

Rv0

RBSE-148

– Added or reconfigured E-DCH MAC-d flow

(for DCCH)

RBSE-149

– E-DCH MAC-d flow identity

1

RBSE-150

– E-DCH MAC-d flow power offset

0

RBSE-151

– E-DCH MAC-d flow maximum number of retransmissions

7

RBSE-152

– E-DCH MAC-d flow multiplexing list

Not Present

RBSE-153

– CHOICE transmission grant type

Non-scheduled grant info

RBSE-154

– Max MAC-e PDU contents size

114 bits

RBSE-155

– 2 ms non-scheduled transmission grant HARQ process allocation

Not Present

RBSE-156

– Added or reconfigured E-DCH MAC-d flow

(for DTCH)

RBSE-157

– E-DCH MAC-d flow identity

2

RBSE-158

– E-DCH MAC-d flow power offset

0

RBSE-159

– E-DCH MAC-d flow maximum number of retransmissions

7

RBSE-160

– E-DCH MAC-d flow multiplexing list

Not Present

RBSE-161

– CHOICE transmission grant type

Scheduled grant info

RBSE-162

CHOICE mode

Not Present

R99 and Rel-4 only

RBSE-163

DL Transport channel information common for all transport channels

Not Present

RBSE-164

DL Transport channel information common for all transport channels

RBSE-165

– SCCPCH TFCS

Not Present

RBSE-166

– CHOICE mode

FDD

RBSE-167

– CHOICE DL parameters

Explicit

RBSE-168

– DL DCH TFCS

RBSE-169

– CHOICE TFCI Signalling

Normal

RBSE-170

– TFCI Field 1 Information

RBSE-171

– CHOICE TFCS representation

Complete reconfiguration

RBSE-172

– TFCS complete reconfigure

RBSE-173

– CHOICE CTFC Size

2 bit CTFC

RBSE-174

– CTFC information

2 TFCs

RBSE-175

– 2bit CTFC

0

RBSE-176

– Power offset Information

RBSE-177

– CHOICE Gain Factors

computedGainFactors

RBSE-178

– Reference TFC ID

0

RBSE-179

– Power offset Pp-m

Not Present

RBSE-180

– 2bit CTFC

1

RBSE-181

– Power offset Information

RBSE-182

– CHOICE Gain Factors

signalledGainFactors

RBSE-183

– CHOICE mode

FDD

RBSE-184

– Gain factor ßc

15

RBSE-185

– Gain factor ßd

15

RBSE-186

– Reference TFC ID

0

RBSE-187

– CHOICE mode

FDD

RBSE-188

– Power offset Pp-m

Not Present

RBSE-189

Deleted TrCH information list

Not Present

RBSE-190

Added or Reconfigured TrCH information list

1 TrCH added

RBSE-191

– Added or Reconfigured DL TrCH information

HS-DSCH for DTCH added

RBSE-192

– Downlink transport channel type

HS-DSCH

RBSE-193

– DL Transport channel identity

Not Present

RBSE-194

– CHOICE DL parameters

HS-DSCH

RBSE-195

– HARQ Info

RBSE-196

– Number of Processes

Reference to TS34.121 [2] Annex C Fixed Reference Channels

RBSE-197

– CHOICE Memory Partitioning

Explicit

RBSE-198

– Memory size

Reference to TS34.121 [2] Annex C Fixed Reference Channels parameter “Number of HARQ Processes".

RBSE-199

– Process Memory Size

Reference to TS34.121 [2] Annex C Fixed Reference Channels parameter “Number of SML’s per HARQ Proc.”.

RBSE-200

– Additional memory sizes for MIMO

Not Present

Rel-7

RBSE-201

– CHOICE DL MAC header type

MAC-hs

Rel-7

RBSE-202

– Added or reconfigured MAC-d flow

RBSE-203

– MAC-hs queue to add or reconfigure list

(one queue)

RBSE-204

– MAC-hs queue Id

0

RBSE-205

– MAC-d Flow Identity

0

RBSE-206

– T1

50

RBSE-207

– MAC-hs window size

16

RBSE-208

– MAC-d PDU size Info

RBSE-209

– MAC-d PDU size

Reference to TS34.121 [2] Annex C Fixed Reference Channels

RBSE-210

– MAC-d PDU size index

0

RBSE-211

– MAC-hs queue to delete list

Not present

RBSE-212

– DCH quality target

Not present

RBSE-213

Frequency info

Not present

RBSE-214

Multi-frequency Info

Not present

Rel-7

RBSE-215

DTX-DRX timing information

Not present

Rel-7

RBSE-216

DRX Information

Not present

Rel-7

RBSE-217

HS-SCCH less Information

Not present

Rel-7

RBSE-218

MIMO parameters

Not present

Rel-7

RBSE-219

Maximum allowed UL TX power

33dBm

RBSE-220

CHOICE channel requirement

Uplink DPCH info

Rel-5 and earlier

RBSE-221

Uplink DPCH info

Rel-6

RBSE-222

– Uplink DPCH power control info

RBSE-223

– DPCCH power offset

-40 (-80dB)

RBSE-224

– PC Preamble

1 frame

RBSE-225

– SRB delay

7 frames

RBSE-226

– Power Control Algorithm

Algorithm1

RBSE-227

– TPC step size

0 (1dB)

RBSE-228

– ACK

A1

0

RBSE-229

– ACK

A2

6

RBSE-229a

– NACK

A1

0

RBSE-230

– NACK

A2

6

RBSE-230a

– Ack-Nack repetition factor

1

RBSE-231

– HARQ_preamble_mode

0

RBSE-232

– Scrambling code type

Long

RBSE-233

– Scrambling code number

0 (0 to 16777215)

RBSE-234

– Number of DPDCH

0

RBSE-235

– spreading factor

Not present

RBSE-236

– TFCI existence

FALSE

RBSE-237

– Number of FBI bit

Not present

RBSE-238

– Puncturing Limit

Not present

RBSE-239

E-DCH info

Rel-6

RBSE-240

– MAC-es/e reset indicator

TRUE

RBSE-241

– E-DPCCH info

RBSE-242

– E-DPCCH/DPCCH power offset

0

RBSE-243

– Happy bit delay condition

100 ms

RBSE-244

– E-TFC Boost Info

RBSE-244a

– E-TFCI boost

67

Rel-7

RBSE-245

– Delta T2TP

5 (15 dB)

RBSE-245a

– E-DPDCH power interpolation

Not present

Rel-7

RBSE-246

– E-DPDCH info

RBSE-247

– E-TFCI table index

A1

0

RBSE-248

– E-TFCI table index

A2

1

RBSE-248a

– E-DCH minimum set E-TFCI

67

RBSE-249

– Reference E-TFCIs

2 E-TFCI

RBSE-250

– Reference E-TFCI

1

RBSE-251

– Reference E-TFCI PO

12

RBSE-252

– Reference E-TFCI

68

RBSE-252a

– Reference E-TFCI PO

19

RBSE-252b

– Minimum reduced E-DPDCH gain factor.

A1

30/15

Rel-8

RBSE-252c

– Minimum reduced E-DPDCH gain factor.

A2

84/15

Rel-8

RBSE-252d

– Maximum channelisation codes

2sf2and2sf4

RBSE-253

– PLnon-max

0.84

RBSE-254

– Scheduling Information Configuration

RBSE-255

– Periodicity for Scheduling Info – no grant

Not present

RBSE-256

– Periodicity for Scheduling Info – grant

Not present

RBSE-257

– Power Offset for Scheduling Info

0

RBSE-258

– 3-Index-Step Threshold

Not present

RBSE-259

– 2-Index-Step Threshold

Not present

RBSE-260

– Scheduled Transmission configuration

RBSE-261

– 2ms scheduled transmission grant HARQ process allocation

Not present

RBSE-262

– Serving Grant

Not present

RBSE-263

– UL 16QAM settings

A1

Not present

Rel-7

RBSE-264

– UL 16QAM settings

A2

Rel-7

RBSE-264a

– BetaEd gain E-AGCH table selection

1

RBSE-264b

CHOICE Mode

FDD

R99 and Rel-4 only

RBSE-265

– Downlink PDSCH information

Not Present

R99 and Rel-4 only

RBSE-266

Uplink secondary cell info FDD

Rel-9

RBSE-267

– Secondary serving E-DCH cell info

RBSE-268

– Primary E-RNTI

‘1010 1010 1010 1010’

RBSE-269

– Secondary E-RNTI

Not Present

RBSE-270

– Secondary E-DCH info common

RBSE-271

– Frequency info

RBSE-272

– UARFCN uplink (Nu)

Reference to clause 5.1 Test frequencies

RBSE-273

– UARFCN downlink (Nd)

Reference to clause 5.1 Test frequencies

RBSE-274

– Scrambling code type

Short

RBSE-275

– Scrambling code number

0

RBSE-276

– 2ms scheduled transmission grant HARQ process allocation

Not Present

RBSE-277

– Serving Grant

RBSE-278

– Primary/Secondary Grant Selector

Primary

RBSE-279

– Minimum reduced E-DPDCH gain factor

A1

30/15

RBSE-280

– Minimum reduced E-DPDCH gain factor

A2

84/15

RBSE-280a

– E-DCH minimum set E-TFCI

67

RBSE-281

– DPCCH Power offset for secondary UL frequency

0 dB

RBSE-282

– PC Preamble

0 frame

RBSE-283

– Downlink information per radio link list on secondary UL frequency

RBSE-284

– Downlink information for each radio link on secondary UL frequency

1

RBSE-285

– Primary CPICH info

RBSE-286

– Primary scrambling code

Ref. to the Default setting in clause 6.1 (FDD)

RBSE-287

– Cell ID

Not Present

RBSE-288

– Downlink F-DPCH info for each RL on secondary UL frequency

RBSE-289

– Downlink F-DPCH info for each RL

RBSE-290

– Primary CPICH usage for channel estimate

RBSE-291

– F-DPCH frame offset

Set to value Default DPCH Offset Value (as currently stored in SS) mod 38 400

RBSE-292

– F-DPCH slot format

3 if UE supports enhanced F-DPCH, otherwise Not Present

RBSE-293

– Secondary CPICH info

Not Present

RBSE-294

– Secondary scrambling code

Not Present

RBSE-295

– Code number

12

RBSE-296

– TPC combination index

0

RBSE-297

– STTD

FALSE

RBSE-298

– E-AGCH Info

RBSE-299

– E-AGCH Channelisation Code

10

RBSE-300

– E-HICH Info

RBSE-301

– Channelisation Code

4

RBSE-302

– Signature Sequence

1

RBSE-303

– E-RGCH Info

RBSE-304

– Signature Sequence

0

RBSE-305

– RG combination index

0

RBSE-306

Downlink HS-PDSCH Information

RBSE-307

– HS-SCCH Info

RBSE-308

– CHOICE mode

FDD

RBSE-309

– DL Scrambling Code

Not present

RBSE-310

– HS-SCCH Channelisation Code Information

RBSE-311

– HS-SCCH Channelisation Code

2

RBSE-312

– HS-SCCH Channelisation Code

3

RBSE-313

– Measurement Feedback Info

RBSE-314

– CHOICE mode

FDD

RBSE-315

– POhsdsch

6 dB

RBSE-316

– CQI Feedback cycle, k

2 ms

RBSE-317

– CQI repetition factor

1

RBSE-318

– CQI

A1

0

RBSE-319

– CQI

A2

6

RBSE-319a

– CHOICE mode

FDD

RBSE-320

– Downlink 64QAM configured

Not Present

Rel-7

RBSE-321

Downlink information common for all radio links

Not Present

RBSE-322

Downlink information for each radio link list

RBSE-323

– Downlink information for each radio link

RBSE-324

– Choice mode

FDD

RBSE-325

– Primary CPICH info

RBSE-326

– Primary scrambling code

Ref. to clause 6.1 "Default settings (FDD)"

RBSE-327

– PDSCH with SHO DCH info

Not Present

R99 and Rel-4 only

RBSE-328

– PDSCH code mapping

Not Present

R99 and Rel-4 only

RBSE-329

– Serving HS-DSCH radio link indicator

TRUE

RBSE-330

– Serving E-DCH radio link indicator

TRUE

RBSE-331

– Downlink DPCH info for each RL

RBSE-332

– CHOICE mode

FDD

RBSE-333

– Primary CPICH usage for channel estimation

Primary CPICH may be used

RBSE-334

– DPCH frame offset

Set to value Default DPCH Offset Value (as currently stored in SS) mod 38 400

RBSE-335

– Secondary CPICH info

Not Present

RBSE-336

– DL channelisation code

RBSE-337

– Secondary scrambling code

Not Present

RBSE-338

– Spreading factor

256

RBSE-339

– Code number

192

RBSE-340

– Scrambling code change

No code change

RBSE-341

– TPC combination index

0

RBSE-342

– SSDT Cell Identity

Not Present

R99 and Rel-4 only

RBSE-343

– Closed loop timing adjustment mode

Not Present

RBSE-344

– E-AGCH Info

Rel-6

RBSE-345

– E-AGCH Channelisation Code

14

RBSE-346

– CHOICE E-HICH Information

Rel-6

RBSE-347

– E-HICH Information

RBSE-348

– DL Scrambling code

Not Present (default is primary)

RBSE-349

– Channelisation code

6

RBSE-350

– Signature sequence

1

RBSE-351

– CHOICE E-RGCH Information

Not Present

Rel-6

RBSE-352

– SCCPCH information for FACH

Not Present

R99 and Rel-4 only

RBSE-353

Downlink secondary cell info FDD

Rel-8

RBSE-354

– CHOICE Configuration info

New configuration

RBSE-355

– New H-RNTI

‘1010 1010 1010 1010’

RBSE-356

– Downlink 64QAM configured

Not Present

RBSE-357

– HS-DSCH TB size table

Not Present

RBSE-358

– Primary CPICH info

RBSE-359

– Primary scrambling code

Ref. to the Default setting in clause 6.1 (FDD)

RBSE-360

– DL Scrambling Code

Not Present

RBSE-361

– HS-SCCH Channelisation Code Information

RBSE-362

– HS-SCCH Channelisation Code

2

RBSE-363

– HS-SCCH Channelisation Code

3

RBSE-364

– Measurement Power Offset

6 dB

RBSE-365

– UARFCN downlink (Nd)

Reference to clause 5.1 Test frequencies

RBSE-366

MBMS PL Service Restriction Information

Not Present

Rel-6

RBSE-367

Condition

Explanation

Version

A1

This IE is used when test is performed with UL E-DCH reference measurement channel for DC-HSUPA using BPSK as specified in TS 34.121-1 subclause C.2.6

A2

This IE is used when test is performed with UL E-DCH reference measurement channel for DC-HSUPA using 16QAM as specified in TS 34.121-1 subclause C.2.7

Contents of RRC CONNECTION RELEASE message: UM

Information Element

Value/remark

Version

Message Type

U-RNTI

This IE is set to the following value when the message is transmitted on the CCCH. When transmitted on DCCH, this is absent.

R99, Rel-4

– SRNC identity

0000 0000 0001B

– S-RNTI

0000 0000 0000 0000 0001B

CHOICE identity type

This IE is set to the following value when the message is transmitted on the CCCH. When transmitted on DCCH, this is absent.

Rel-5

– U-RNTI

– SRNC identity

0000 0000 0001B

– S-RNTI

0000 0000 0000 0000 0001B

RRC transaction identifier

Arbitrarily selects an integer between 0 and 3

Integrity check info

This IE is present when this message is transmitted on downlink DCCH. Else, this IE and the sub-IEs are omitted.

– Message authentication code

SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I.

– RRC Message sequence number

SS provides the value of this IE, from its internal counter.

N308

2 (for CELL_DCH state). Not Present (for UE in other connected mode states).

Release cause

Normal event

Rplmn information

Not Present

Redirection info

Not Present

Rel-6

Contents of RRC CONNECTION SETUP message: UM

Information Element

Condition

Value/remark

Version

Index

Message Type

RCSU-001

Initial UE identity

Select the same identity as in the IE "Initial UE Identity" in received "RRC CONNECTION REQUEST" message

RCSU-002

RRC transaction identifier

Arbitrarily selects an integer between 0 and 3

RCSU-003

Activation time

Not Present(Now)

RCSU-004

New U-RNTI

RCSU-005

– SRNC identity

0000 0000 0001B

RCSU-006

– S-RNTI

0000 0000 0000 0000 0001B

RCSU-007

New C-RNTI

Not Present

RCSU-008

New H-RNTI

Not Present

Rel-6

RCSU-009

New Primary E-RNTI

Not Present

Rel-6

RCSU-010

New Secondary E-RNTI

Not Present

Rel-6

RCSU-011

RRC State Indicator

CELL_DCH

RCSU-012

UTRAN DRX cycle length coefficient

9

RCSU-013

Capability update requirement

RCSU-014

– UE radio access FDD capability update requirement

TRUE

RCSU-015

– UE radio access TDD capability update requirement

FALSE

RCSU-016

– UE radio access 3.84 Mcps TDD capability update requirement

FALSE

Rel-4

RCSU-017

– UE radio access 1.28 Mcps TDD capability update requirement

FALSE

Rel-4

RCSU-018

– System specific capability update requirement list

1 entry (for Rel-7 and earlier)

2 entry (for Rel-8 and later)

RCSU-019

– System specific capability update requirement

GSM

RCSU-019a

– System specific capability update requirement

E-UTRA

Rel-8

RCSU-019b

CHOICE specification mode

Complete specification

Rel-5

RCSU-020

– Complete specification

Rel-5

RCSU-021

– Signalling RB information to setup list

4 SRBs

RCSU-022

– Signalling RB information to setup

(UM DCCH for RRC)

RCSU-023

– RB identity

Not Present

RCSU-024

– CHOICE RLC info type

RLC info

RCSU-025

– CHOICE Uplink RLC mode

UM RLC

RCSU-026

– Transmission RLC discard

Not Present

RCSU-027

– CHOICE Downlink RLC mode

UM RLC

RCSU-028

– DL UM RLC LI size

7 bit

Rel-6

RCSU-029

– One sided RLC re-establishment

FALSE

Rel-6

RCSU-030

– RB mapping info

RCSU-031

– Information for each multiplexing option

2 RBMuxOptions

RCSU-032

– RLC logical channel mapping indicator

Not Present

RCSU-033

– Number of RLC logical channels

1

RCSU-034

– Uplink transport channel type

DCH

RCSU-035

– UL Transport channel identity

5

RCSU-036

– Logical channel identity

1

RCSU-037

– CHOICE RLC size list

Configured

RCSU-038

– MAC logical channel priority

1

RCSU-039

– Downlink RLC logical channel info

RCSU-040

– Number of RLC logical channels

1

RCSU-041

– Downlink transport channel type

DCH

RCSU-042

– DL DCH Transport channel identity

10

RCSU-043

– DL DSCH Transport channel identity

Not Present

RCSU-044

– Logical channel identity

1

RCSU-045

– RLC logical channel mapping indicator

Not Present

RCSU-046

– Number of RLC logical channels

1

RCSU-047

– Uplink transport channel type

RACH

RCSU-048

– UL Transport channel identity

Not Present

RCSU-049

– Logical channel identity

1

RCSU-050

– CHOICE RLC size list

Explicit List

RCSU-051

– RLC size index

Reference to clause 6 Parameter Set

RCSU-052

– MAC logical channel priority

1

RCSU-053

– Downlink RLC logical channel info

RCSU-054

– Number of RLC logical channels

1

RCSU-055

– Downlink transport channel type

FACH

RCSU-056

– DL DCH Transport channel identity

Not Present

RCSU-057

– DL DSCH Transport channel identity

Not Present

RCSU-058

– Logical channel identity

1

RCSU-059

– Signalling RB information to setup

(AM DCCH for RRC)

RCSU-060

– RB identity

Not Present

RCSU-061

– CHOICE RLC info type

RCSU-062

– RLC info

RCSU-063

– CHOICE Uplink RLC mode

AM RLC

RCSU-064

– Transmission RLC discard

RCSU-065

– SDU discard mode

No Discard

RCSU-066

– MAX_DAT

15

RCSU-067

– Transmission window size

128

RCSU-068

– Timer_RST

500

RCSU-069

– Max_RST

1

RCSU-070

– Polling info

RCSU-071

– Timer_poll_prohibit

200

RCSU-072

– Timer_poll

200

RCSU-073

– Poll_PDU

Not Present

RCSU-074

– Poll_SDU

1

RCSU-075

– Last transmission PDU poll

TRUE

RCSU-076

– Last retransmission PDU poll

TRUE

RCSU-077

– Poll_Windows

99

RCSU-078

– Timer_poll_periodic

Not Present

RCSU-079

– CHOICE Downlink RLC mode

AM RLC

RCSU-080

– DL RLC PDU size

96 bits

Rel-6

RCSU-081

– DL RLC PDU size

A1

144 bits

Rel-6

RCSU-082

– In-sequence delivery

TRUE

RCSU-083

– Receiving window size

128

RCSU-084

– Downlink RLC status info

RCSU-085

– Timer_status_prohibit

200

RCSU-086

– Timer_EPC

Not Present

RCSU-087

– Missing PDU indicator

TRUE

RCSU-088

– Timer_STATUS_periodic

Not Present

RCSU-089

– RB mapping info

RCSU-090

– Information for each multiplexing option

2 RBMuxOptions

RCSU-091

– RLC logical channel mapping indicator

Not Present

RCSU-092

– Number of RLC logical channels

1

RCSU-093

– Uplink transport channel type

DCH

RCSU-094

– UL Transport channel identity

5

RCSU-095

– Logical channel identity

2

RCSU-096

– CHOICE RLC size list

Configured

RCSU-097

– MAC logical channel priority

2

RCSU-098

– Downlink RLC logical channel info

RCSU-099

– Number of RLC logical channels

1

RCSU-100

– Downlink transport channel type

DCH

RCSU-101

– DL DCH Transport channel identity

10

RCSU-102

– DL DSCH Transport channel identity

Not Present

RCSU-103

– Logical channel identity

2

RCSU-104

– RLC logical channel mapping indicator

Not Present

RCSU-105

– Number of RLC logical channels

1

RCSU-106

– Uplink transport channel type

RACH

RCSU-107

– UL Transport channel identity

Not Present

RCSU-108

– Logical channel identity

2

RCSU-109

– CHOICE RLC size list

Explicit List

RCSU-110

– RLC size index

Reference to clause 6 Parameter Set

RCSU-111

– MAC logical channel priority

2

RCSU-112

– Downlink RLC logical channel info

RCSU-113

– Number of RLC logical channels

1

RCSU-114

– Downlink transport channel type

FACH

RCSU-115

– DL DCH Transport channel identity

Not Present

RCSU-116

– DL DSCH Transport channel identity

Not Present

RCSU-117

– Logical channel identity

2

RCSU-118

– Signalling RB information to setup

(AM DCCH for NAS_DT High priority)

RCSU-119

– RB identity

Not Present

RCSU-120

– CHOICE RLC info type

RCSU-121

– RLC info

RCSU-122

– CHOICE Uplink RLC mode

AM RLC

RCSU-123

– Transmission RLC discard

RCSU-124

– SDU discard mode

No Discard

RCSU-125

– MAX_DAT

15

RCSU-126

– Transmission window size

128

RCSU-127

– Timer_RST

500

RCSU-128

– Max_RST

1

RCSU-129

– Polling info

RCSU-130

– Timer_poll_prohibit

200

RCSU-131

– Timer_poll

200

RCSU-132

– Poll_PDU

Not Present

RCSU-133

– Poll_SDU

1

RCSU-134

– Last transmission PDU poll

TRUE

RCSU-135

– Last retransmission PDU poll

TRUE

RCSU-136

– Poll_Windows

99

RCSU-137

– Timer_poll_periodic

Not Present

RCSU-138

– CHOICE Downlink RLC mode

AM RLC

RCSU-139

– DL RLC PDU size

96 bits

Rel-6

RCSU-140

– DL RLC PDU size

A1

144 bits

Rel-6

RCSU-141

– In-sequence delivery

TRUE

RCSU-142

– Receiving window size

128

RCSU-143

– Downlink RLC status info

RCSU-144

– Timer_status_prohibit

200

RCSU-145

– Timer_EPC

Not Present

RCSU-146

– Missing PDU indicator

TRUE

RCSU-147

– Timer_STATUS_periodic

Not Present

RCSU-148

– RB mapping info

RCSU-149

– Information for each multiplexing option

2 RBMuxOptions

RCSU-150

– RLC logical channel mapping indicator

Not Present

RCSU-151

– Number of RLC logical channels

1

RCSU-152

– Uplink transport channel type

DCH

RCSU-153

-UL Transport channel identity

5

RCSU-154

– Logical channel identity

3

RCSU-155

– CHOICE RLC size list

Configured

RCSU-156

– MAC logical channel priority

3

RCSU-157

– Downlink RLC logical channel info

RCSU-158

– Number of RLC logical channels

1

RCSU-159

– Downlink transport channel type

DCH

RCSU-160

– DL DCH Transport channel identity

10

RCSU-161

– DL DSCH Transport channel identity

Not Present

RCSU-162

– Logical channel identity

3

RCSU-163

– RLC logical channel mapping indicator

Not Present

RCSU-164

– Number of RLC logical channels

1

RCSU-165

– Uplink transport channel type

RACH

RCSU-166

– UL Transport channel identity

Not Present

RCSU-167

– Logical channel identity

3

RCSU-168

– CHOICE RLC size list

Explicit List

RCSU-169

– RLC size index

Reference to clause 6 Parameter Set

RCSU-170

– MAC logical channel priority

3

RCSU-171

– Downlink RLC logical channel info

RCSU-172

– Number of RLC logical channels

1

RCSU-173

– Downlink transport channel type

FACH

RCSU-174

– DL DCH Transport channel identity

Not Present

RCSU-175

– DL DSCH Transport channel identity

Not Present

RCSU-176

– Logical channel identity

3

RCSU-177

– Signalling RB information to setup

(AM DCCH for NAS_DT Low priority)

RCSU-178

– RB identity

Not Present

RCSU-179

– CHOICE RLC info type

RCSU-180

– RLC info

RCSU-181

– CHOICE Uplink RLC mode

AM RLC

RCSU-182

– Transmission RLC discard

RCSU-183

– SDU discard mode

No Discard

RCSU-184

– MAX_DAT

15

RCSU-185

– Transmission window size

128

RCSU-186

– Timer_RST

500

RCSU-187

– Max_RST

1

RCSU-188

– Polling info

RCSU-189

– Timer_poll_prohibit

200

RCSU-190

– Timer_poll

200

RCSU-191

– Poll_PDU

Not Present

RCSU-192

– Poll_SDU

1

RCSU-193

– Last transmission PDU poll

TRUE

RCSU-194

– Last retransmission PDU poll

TRUE

RCSU-195

– Poll_Windows

99

RCSU-196

– Timer_poll_periodic

Not Present

RCSU-197

– CHOICE Downlink RLC mode

AM RLC

RCSU-198

– DL RLC PDU size

96 bits

Rel-6

RCSU-199

– DL RLC PDU size

A1

144 bits

Rel-6

RCSU-200

– In-sequence delivery

TRUE

RCSU-201

– Receiving window size

128

RCSU-202

– Downlink RLC status info

RCSU-203

– Timer_status_prohibit

200

RCSU-204

– Timer_EPC

Not Present

RCSU-205

– Missing PDU indicator

TRUE

RCSU-206

– Timer_STATUS_periodic

Not Present

RCSU-207

– RB mapping info

RCSU-208

– Information for each multiplexing option

2 RBMuxOptions

RCSU-209

– RLC logical channel mapping indicator

Not Present

RCSU-210

– Number of RLC logical channels

1

RCSU-211

– Uplink transport channel type

DCH

RCSU-212

– UL Transport channel identity

5

RCSU-213

– Logical channel identity

4

RCSU-214

– CHOICE RLC size list

Configured

RCSU-215

– MAC logical channel priority

4

RCSU-216

– Downlink RLC logical channel info

RCSU-217

– Number of RLC logical channels

1

RCSU-218

– Downlink transport channel type

DCH

RCSU-219

– DL DCH Transport channel identity

10

RCSU-220

– DL DSCH Transport channel identity

Not Present

RCSU-221

– Logical channel identity

4

RCSU-222

– RLC logical channel mapping indicator

Not Present

RCSU-223

– Number of RLC logical channels

1

RCSU-224

– Uplink transport channel type

RACH

RCSU-225

– UL Transport channel identity

Not Present

RCSU-226

– Logical channel identity

4

RCSU-227

– CHOICE RLC size list

Explicit List

RCSU-228

– RLC size index

Reference to clause 6 Parameter Set

RCSU-229

– MAC logical channel priority

4

RCSU-230

– Downlink RLC logical channel info

RCSU-231

– Number of RLC logical channels

1

RCSU-232

– Downlink transport channel type

FACH

RCSU-233

– DL DCH Transport channel identity

Not Present

RCSU-234

– DL DSCH Transport channel identity

Not Present

RCSU-235

– Logical channel identity

4

RCSU-236

UL Transport channel information for all transport channels

RCSU-237

– PRACH TFCS

Not Present

RCSU-238

– CHOICE Mode

FDD

RCSU-239

– TFC subset

Not Present

RCSU-240

– UL DCH TFCS

RCSU-241

– CHOICE TFCI signalling

Normal

RCSU-242

– TFCI Field 1 information

RCSU-243

– CHOICE TFCS representation

Complete reconfiguration

RCSU-244

– TFCS complete reconfiguration information

RCSU-245

– CHOICE CTFC Size

2 bit CTFC

RCSU-246

– CTFC information

2 TFCs

RCSU-247

– 2bit CTFC

0

RCSU-248

– Power offset Information

RCSU-249

– CHOICE Gain Factors

computedGainFactors

RCSU-250

– Reference TFC ID

0

RCSU-251

– CHOICE mode

FDD

RCSU-252

– Power offset Pp-m

Not Present

RCSU-253

– 2bit CTFC

1

RCSU-254

– Power offset Information

RCSU-255

– CHOICE Gain Factors

signalledGainFactors

RCSU-256

– CHOICE mode

FDD

RCSU-257

– Gain factor ßc

15

RCSU-258

– Gain factor ßd

15

RCSU-259

– Reference TFC ID

0

RCSU-260

– CHOICE mode

FDD

RCSU-261

– Power offset Pp-m

Not Present

RCSU-262

Added or Reconfigured UL TrCH information list

1

RCSU-263

– Added or Reconfigured UL TrCH information

RCSU-264

– Uplink transport channel type

DCH

RCSU-265

– UL Transport channel identity

5

RCSU-266

– TFS

RCSU-267

– CHOICE Transport channel type

Dedicated transport channels

RCSU-268

– Dynamic Transport Format Information

RCSU-269

– RLC size

96 bits

RCSU-270

– RLC size

A1

144 bits

RCSU-271

– Number of TBs and TTI List

2

RCSU-272

– Transmission Time Interval

Not Present

RCSU-273

– Number of Transport blocks

0

RCSU-274

– Transmission Time Interval

Not Present

RCSU-275

– Number of Transport blocks

1

RCSU-276

– CHOICE Logical channel List

ALL

RCSU-277

– Semi-static Transport Format Information

RCSU-278

– Transmission time interval

40

RCSU-279

– Type of channel coding

Convolutional

RCSU-280

– Coding Rate

1/3

RCSU-281

– Rate matching attribute

256

RCSU-282

– CRC size

12

RCSU-283

– CRC size

A1

16

RCSU-284

DL Transport channel information common for all transport channel

RCSU-285

– SCCPCH TFCS

Not Present

RCSU-286

– CHOICE mode

FDD

RCSU-287

– CHOICE DL parameters

Same as UL

RCSU-288

Added or Reconfigured DL TrCH information list

1

RCSU-289

– Added or Reconfigured DL TrCH information

RCSU-290

– Downlink transport channel type

DCH

RCSU-291

– DL Transport channel identity

10

RCSU-292

– CHOICE DL parameters

SameAasUL

RCSU-293

– Uplink transport channel type

DCH

RCSU-294

– UL TrCH Identity

5

RCSU-295

– DCH quality target

RCSU-296

– BLER Quality value

-20 (-2.0)

RCSU-297

Frequency info

Not Present

RCSU-298

Maximum allowed UL TX power

Not Present

RCSU-299

CHOICE channel requirement

Uplink DPCH info

Rel-5 and earlier

RCSU-300

Uplink DPCH info

Rel-6

RCSU-301

– Uplink DPCH power control info

RCSU-302

– DPCCH power offset

-40 (-80dB)

RCSU-303

– PC Preamble

1 frame

RCSU-304

– SRB delay

7 frames

RCSU-305

– Power Control Algorithm

Algorithm1

RCSU-306

– TPC step size

0 (1dB)

RCSU-307

– ACK

Not Present

Rel-5

RCSU-308

– NACK

Not Present

Rel-5

RCSU-309

– Ack-Nack repetition factor

Not Present

Rel-5

RCSU-310

– HARQ_preamble_mode

0

Rel-6

RCSU-311

– CHOICE mode

FDD

RCSU-312

– Scrambling code type

Long

RCSU-313

– Scrambling code number

0 (0 to 16777215)

RCSU-314

– Number of DPDCH

Not Present (1)

RCSU-315

– Spreading factor

256

RCSU-316

– TFCI existence

TRUE

RCSU-317

– Number of FBI bit

Not Present(0)

RCSU-318

– Puncturing Limit

1

RCSU-319

E-DCH Info

Not Present

Rel-6

RCSU-320

Downlink HS-PDSCH Information

Not Present

Rel-6

RCSU-321

Downlink information common for all radio links

RCSU-322

– Downlink DPCH info common for all RL

RCSU-323

– Timing Indication

Initialize

RCSU-324

– CFN-targetSFN frame offset

Not Present

RCSU-325

– Downlink DPCH power control information

RCSU-326

– CHOICE mode

FDD

RCSU-327

– DPC mode

0 (single)

RCSU-328

– CHOICE mode

FDD

RCSU-329

– Power offset P Pilot-DPDCH

0

RCSU-330

– DL rate matching restriction information

Not Present

RCSU-331

– Spreading factor

256

RCSU-332

– Fixed or Flexible Position

Fixed

RCSU-333

– TFCI existence

FALSE

RCSU-334

– CHOICE SF

RCSU-335

– Number of bits for Pilot bits

8

RCSU-336

– DPCH compressed mode info

Not Present

RCSU-337

– TX Diversity mode

None

RCSU-338

– SSDT information

Not Present

R99 and Rel-4 only

RCSU-339

– Default DPCH Offset Value

Arbitrary set to value 0..306688 by step of 512

RCSU-340

Downlink information for per radio links list

RCSU-341

-Downlink information for each radio links

RCSU-342

– CHOICE mode

FDD

RCSU-343

– Primary CPICH info

RCSU-344

– Primary scrambling code

Reference to clause 6.1 "Default settings (FDD)"

RCSU-345

– PDSCH with SHO DCH info

Not Present

R99 and Rel-4 only

RCSU-346

– PDSCH code mapping

Not Present

R99 and Rel-4 only

RCSU-347

– Serving HS-DSCH radio link indicator

FALSE

Rel-6

RCSU-348

– Serving E-DCH radio link indicator

FALSE

Rel-6

RCSU-349

– Downlink DPCH info for each RL

RCSU-350

– CHOICE mode

FDD

RCSU-351

– Primary CPICH usage for channel estimation

Primary CPICH may be used

RCSU-352

– DPCH frame offset

Set to value : Default DPCH Offset Value mod 38 400

RCSU-353

– Secondary CPICH info

Not Present

RCSU-354

– DL channelisation code

RCSU-355

– Secondary scrambling code

Not Present

RCSU-356

– Spreading factor

256

RCSU-357

– Code number

192

RCSU-358

– Scrambling code change

Not Present

RCSU-359

– TPC combination index

0

RCSU-360

– SSDT Cell Identity

Not Present

R99 and Rel-4 only

RCSU-361

– Closed loop timing adjustment mode

Not Present

RCSU-362

– E-AGCH Info

Not Present

Rel-6

RCSU-363

– E-HICH Information

Not Present

Rel-6

RCSU-364

– E-RGCH Information

Not Present

Rel-6

RCSU-365

– SCCPCH information for FACH

Not Present

R99 and Rel-4 only

RCSU-366

Condition

Explanation

A1

UE supporting 64kbps(Chanel2)

Contents of SECURITY MODE COMMAND message: AM

Information Element

Condition

Value/remark

Message Type

A1, A2

RRC transaction identifier

Arbitrarily selects an integer between 0 and 3

Integrity check info

– Message authentication code

Set to an arbitrarily selected 32-bits integer. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I.

– RRC Message Sequence Number

Set to an arbitrarily selected integer between 0 and 15

Security capability

– Ciphering algorithm capability

– UEA0

If the UE has indicated support for ciphering algorithm UEA0 in the IE "security capability" in the RRC CONNECTION SETUP COMPLETE message, this IE is set to TRUE.

– UEA1

If the UE has indicated support for ciphering algorithm UEA1 in the IE "security capability" in the RRC CONNECTION SETUP COMPLETE message, this IE is set to TRUE.

– Spare

Spare 2-15 = FALSE

– Integrity protection algorithm capability

0000000000000010B (UIA1)

– UIA1

TRUE

– Spare

Spare 0 and Spare 2-15 = FALSE

Ciphering mode info

This presence of this IE is dependent on IXIT statements in TS 34.123-2. If ciphering is indicated to be active, this IE present with the values of the sub IEs as stated below. Else, this IE is omitted.

– Ciphering mode command

Start/restart

– Ciphering algorithm

UEA0 or UEA1. The indicated algorithm must be one of the algorithms supported by the UE as indicated in the IE "security capability" in the RRC CONNECTION SETUP COMPLETE message.

– Ciphering activation time for DPCH

Not Present

– Radio bearer downlink ciphering activation time info

– Radio bearer activation time

– RB identity

1

– RLC sequence number

Current RLC SN

– RB identity

2

– RLC sequence number

Current RLC SN+3(or Calculated Value)

– RB identity

3

– RLC sequence number

Current RLC SN

– RB identity

4

– RLC sequence number

Current RLC SN

Integrity protection mode info

– Integrity protection mode command

Start

– Downlink integrity protection activation info

Not Present

– Integrity protection algorithm

UIA1

– Integrity protection initialisation number

SS selects an arbitrary 32 bits number for FRESH.

The first/ leftmost bit of the bit string contains the most significant bit of the FRESH.A1

CN domain identity

CS or PS

UE system specific security capability

A1

Not Present

UE system specific security capability

A2

– Inter-RAT UE security capability

– CHOICE system

GSM

– GSM security capability

The indicated algorithms must be the same as the algorithms supported by the UE as indicated in the IE " UE system specific capability " in the RRC CONNECTION SETUP COMPLETE message.

Condition

Explanation

A1

UE not supporting GSM

A2

UE supporting GSM