9.2.1 Default Message Contents for RF (FDD)
34.1083GPPCommon test environments for User Equipment (UE)Conformance testingRelease 15TS
Contents of Activate RB Test Mode message
|
Information Element |
Value/remark |
|
Protocol discriminator |
F (Length 1/2) |
|
Skip indicator |
0 (Length 1/2) |
|
Message Type |
44h |
Contents of Close UE Test Loop message (UE test loop mode 1 without Dummy DCCH transmission)
|
Information Element |
Value/remark |
|
Protocol discriminator |
F (Length 1/2) |
|
Skip indicator |
0 (Length 1/2) |
|
Message Type |
40h |
|
UE test loop mode |
00h |
|
UE test loop mode 1 LB setup |
03h 00h F4h 0Ah |
Contents of Close UE Test Loop message (UE test loop mode 2 without Dummy DCCH transmission)
|
Information Element |
Value/remark |
|
Protocol discriminator |
F (Length 1/2) |
|
Skip indicator |
0 (Length 1/2) |
|
Message Type |
40h |
|
UE test loop mode |
01h |
Contents of Open UE Test Loop message
|
Information Element |
Value/remark |
|
Protocol discriminator |
F (Length 1/2) |
|
Skip indicator |
0 (Length 1/2) |
|
Message Type |
42h |
Contents of MBMS COMMON P-T-M RB INFORMATION message: UM
|
Information Element |
Value/remark |
Version |
|---|---|---|
|
Message type |
Rel-6 |
|
|
RB information list |
One entry in the list |
Rel-6 |
|
– RB identity |
14 |
Rel-6 |
|
– PDCP info |
||
|
– Support for lossless SRNS relocation |
Not Present |
|
|
– PDCP PDU header |
Absent |
|
|
– Header compression information |
Not Present |
|
|
– RLC info |
||
|
– DL UM RLC LI size |
Selected with DL UM RLC data size |
|
|
– DL Duplication Avoidance and Reordering info |
Not Present |
|
|
TrCh information for each TrCh |
One entry in the list |
Rel-6 |
|
– Transport channel identity |
17 |
Rel-6 |
|
– TFS |
||
|
– CHOICE Transport channel type |
Common transport channels |
|
|
– Dynamic Transport format information |
||
|
– RLC Size |
Reference to TS34.121 [2] Annex C.12 DL reference parameters or as specified within test case in TS34.121 [2]. |
|
|
– Number of TBs List |
(This IE is repeated for TFI number.) |
|
|
– Transmission Time Interval |
Not Present |
|
|
– Number of Transport blocks |
Reference to TS34.121 [2] Annex C.12 DL reference parameters or as specified within test case in TS34.121 [2]. |
|
|
– CHOICE Logical channel list |
All |
|
|
– Semi-static Transport Format information |
||
|
– Transmission time interval |
Reference to TS34.121 [2] Annex C.12 DL reference parameters or as specified within test case in TS34.121 [2]. |
|
|
– Type of channel coding |
Reference to TS34.121 [2] Annex C.12 DL reference parameters or as specified within test case in TS34.121 [2]. |
|
|
– Coding Rate |
Reference to TS34.121 [2] Annex C.12 DL reference parameters or as specified within test case in TS34.121 [2]. |
|
|
– Rate matching attribute |
Reference to TS34.121 [2] Annex C.12 DL reference parameters or as specified within test case in TS34.121 [2] |
|
|
– CRC size |
Reference to TS34.121 [2] Annex C.12 DL reference parameters or as specified within test case in TS34.121 [2]. |
|
|
TrCh information for each CCTrCh |
One entry in the list |
Rel-6 |
|
– CCTrCH identity |
1 |
Rel-6 |
|
– TFCS |
||
|
– CHOICE TFCI signalling |
Normal |
|
|
– TFCI Field 1 information |
||
|
– CHOICE TFCS representation |
Complete reconfiguration |
|
|
– TFCS complete reconfiguration information |
||
|
– CHOICE CTFC Size |
Number of bits used must be enough to cover all combinations of CTFC from TS34.121 [2] Annex C.12 parameter set or as specified within test case in TS34.121 [2]. |
|
|
– CTFC information |
This IE is repeated for number of CTFCs from TS34.121 [2] Annex C.12 parameter set or as specified within test case in TS34.121 [2]. |
|
|
– CTFC |
Reference to TS34.121 [2] Annex C.12 parameter set or as specified within test case in TS34.121 [2]. |
|
|
– Power offset information |
Not Present |
|
|
PhyCh information |
One entry in list |
Rel-6 |
|
– PhyCh identity |
13 |
Rel-6 |
|
– Secondary CCPCH info MBMS |
||
|
– CHOICE mode |
FDD |
|
|
– Secondary scrambling code |
Not Present |
|
|
– STTD indicator |
FALSE |
|
|
– Spreading factor |
Reference to TS34.121 [2] Annex C.12 DL reference parameters. |
|
|
– Code number |
Reference to TS34.121 [2] Annex E.6.4 “Downlink physical channels code allocation for MBMS test cases” |
|
|
– Timing Offset |
Not Present Absence of this IE is equivalent to default value 0. |
Contents of PAGING TYPE 1 message: TM (CS)
|
Information Element |
Value/remark |
|
Message Type |
|
|
Paging record list |
|
|
-Paging record |
|
|
– CHOICE Used paging identity |
CN identity |
|
– Paging cause |
Terminating Streaming Call |
|
– CN domain identity |
CS domain |
|
– CHOICE UE identity |
|
|
– IMSI (GSM-MAP) |
Set to the same octet string as in the IMSI stored in the USIM card |
|
BCCH modification info |
Not Present |
Contents of PAGING TYPE 1 message: TM (PS)
|
Information Element |
Value/remark |
|
Message Type |
|
|
Paging record list |
|
|
-Paging record |
|
|
– CHOICE Used paging identity |
CN identity |
|
– Paging cause |
Terminating Interactive Call |
|
– CN domain identity |
PS domain |
|
– CHOICE UE identity |
|
|
– IMSI (GSM-MAP) |
Set to the same octet string as in the IMSI stored in the USIM card |
|
BCCH modification info |
Not Present |
Contents of PAGING TYPE 2 message: TM (PS)
|
Information Element |
Value/remark |
|
Message Type |
|
|
RRC transaction identifier |
Arbitrarily selects one integer between 0 to 3 |
|
Integrity check info |
|
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
|
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
|
– Paging cause |
Terminating Interactive Call |
|
– CN domain identity |
PS domain |
|
– Paging record type identifier |
TMSI(GSM-MAP)/P-TMSI |
Contents of RADIO BEARER SETUP message: AM or UM (Test Loop Mode1)
|
Information Element |
Condition |
Value/remark |
Version |
Index |
|---|---|---|---|---|
|
Message Type |
A1, A3, A4, A5, A6, A7, A8, A9 |
RBST-001 |
||
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
RBST-002 |
||
|
Integrity check info |
RBST-003 |
|||
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
RBST-004 |
||
|
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
RBST-005 |
||
|
Integrity protection mode info |
Not Present |
RBST-006 |
||
|
Ciphering mode info |
Not Present |
RBST-007 |
||
|
Activation time |
(256+CFN-(CFN MOD 8 + 8))MOD 256 |
RBST-008 |
||
|
New U-RNTI |
Not Present |
RBST-009 |
||
|
New C-RNTI |
Not Present |
RBST-010 |
||
|
New DSCH-RNTI |
Not Present |
R99 and Rel-4 only |
RBST-011 |
|
|
New H-RNTI |
Not Present |
Rel-5 |
RBST-012 |
|
|
New Primary E-RNTI |
Not Present |
Rel-6 |
RBST-013 |
|
|
New Secondary E-RNTI |
Not Present |
Rel-6 |
RBST-014 |
|
|
RRC State indicator |
CELL_DCH |
RBST-015 |
||
|
UTRAN DRX cycle length coefficient |
Not Present |
RBST-016 |
||
|
CN information info |
Not Present |
RBST-017 |
||
|
URA identity |
Not Present |
RBST-018 |
||
|
CHOICE specification mode |
Complete specification |
Rel-6 |
RBST-019 |
|
|
– Signalling RB information to setup |
Not Present |
RBST-020 |
||
|
– RAB information for setup list |
A1, A3, A4, A5 |
RBST-021 |
||
|
– RAB information for setup |
RBST-022 |
|||
|
– RAB info |
RBST-023 |
|||
|
– RAB identity |
0000 0001B The first/ leftmost bit of the bit string contains the most significant bit of the RAB identity. |
RBST-024 |
||
|
– CN domain identity |
CS domain |
RBST-025 |
||
|
– NAS Synchronization Indicator |
Not Present |
RBST-026 |
||
|
– Re-establishment timer |
UseT314 |
RBST-027 |
||
|
RBST-028 |
||||
|
– RB information to setup list |
RBST-029 |
|||
|
– RB information to setup |
RBST-030 |
|||
|
– RAB information for setup list |
A6, A7, A8, A9 |
RBST-031 |
||
|
– RAB information for setup |
RBST-032 |
|||
|
– RAB info |
RBST-033 |
|||
|
– RAB identity |
0000 0101B The first/ leftmost bit of the bit string contains the most significant bit of the RAB identity. |
RBST-034 |
||
|
– CN domain identity |
PS domain |
RBST-035 |
||
|
– NAS Synchronization Indicator |
Not Present |
RBST-036 |
||
|
– Re-establishment timer |
UseT315 |
RBST-037 |
||
|
RBST-038 |
||||
|
– RB information to setup list |
RBST-039 |
|||
|
– RB information to setup |
RBST-040 |
|||
|
– RB identity |
A1 |
10 |
RBST-041 |
|
|
– PDCP info |
Not Present |
RBST-042 |
||
|
– CHOICE RLC info type |
RLC info |
RBST-043 |
||
|
– CHOICE Uplink RLC mode |
TM RLC |
RBST-044 |
||
|
– Transmission RLC discard |
Not Present |
RBST-045 |
||
|
– Segmentation indication |
FALSE |
RBST-046 |
||
|
– CHOICE Downlink RLC mode |
TM RLC |
RBST-047 |
||
|
– Segmentation indication |
FALSE |
RBST-048 |
||
|
– One sided RLC re-establishment |
FALSE |
Rel-5 |
RBST-049 |
|
|
– RB mapping info |
RBST-050 |
|||
|
– Information for each multiplexing option |
RBST-051 |
|||
|
– RLC logical channel mapping indicator |
Not Present |
RBST-052 |
||
|
– Number of uplink RLC logical channels |
1 |
RBST-053 |
||
|
– Uplink transport channel type |
DCH |
RBST-054 |
||
|
– UL Transport channel identity |
1 |
RBST-055 |
||
|
– Logical channel identity |
Not Present |
RBST-056 |
||
|
– CHOICE RLC size list |
Configured |
RBST-057 |
||
|
– MAC logical channel priority |
7 |
RBST-058 |
||
|
– Downlink RLC logical channel info |
RBST-059 |
|||
|
– Number of downlink RLC logical channels |
1 |
RBST-060 |
||
|
– Downlink transport channel type |
DCH |
RBST-061 |
||
|
– DL DCH Transport channel identity |
6 |
RBST-062 |
||
|
– DL DSCH Transport channel identity |
Not Present |
RBST-063 |
||
|
– Logical channel identity |
Not Present |
RBST-064 |
||
|
– RB identity |
A3, A4, A5 |
10 |
RBST-065 |
|
|
– PDCP info |
Not Present |
RBST-066 |
||
|
– CHOICE RLC info type |
RLC info |
RBST-067 |
||
|
– CHOICE Uplink RLC mode |
AM RLC |
RBST-068 |
||
|
– Transmission RLC discard |
RBST-069 |
|||
|
– CHOICE SDU discard mode |
No Discard |
RBST-070 |
||
|
– MAX_DAT |
15 |
RBST-071 |
||
|
– Transmission window size |
Selected with Total RLC AM Buffer Size |
RBST-072 |
||
|
– Timer_RST |
500 |
RBST-073 |
||
|
– Max_RST |
4 |
RBST-074 |
||
|
– Polling info |
RBST-075 |
|||
|
– Timer_poll_prohibit |
400 |
RBST-076 |
||
|
– Timer_poll |
400 |
RBST-077 |
||
|
– Poll_PDU |
Not Present |
RBST-078 |
||
|
– Poll_SDU |
1 |
RBST-079 |
||
|
– Last transmission PDU poll |
TRUE |
RBST-080 |
||
|
– Last retransmission PDU poll |
TRUE |
RBST-081 |
||
|
– Poll_Windows |
99 |
RBST-082 |
||
|
– Timer_poll_periodic |
Not Present |
RBST-083 |
||
|
– CHOICE Downlink RLC mode |
AM RLC |
RBST-084 |
||
|
– DL RLC PDU size |
A3 |
1280 bits |
Rel-5 |
RBST-085 |
|
– DL RLC PDU size |
A4 |
2880 bits |
Rel-5 |
RBST-086 |
|
– DL RLC PDU size |
A5 |
3840 bits |
Rel-5 |
RBST-087 |
|
– In-sequence delivery |
A3, A4, A5 |
TRUE |
RBST-088 |
|
|
– Receiving window size |
Selected with Total RLC AM Buffer Size |
RBST-089 |
||
|
– Downlink RLC status info |
RBST-090 |
|||
|
– Timer_status_prohibit |
330 |
RBST-091 |
||
|
– Timer_EPC |
Not Present |
RBST-092 |
||
|
– Missing PDU indicator |
TRUE |
RBST-093 |
||
|
– Timer_STATUS_periodic |
Not Present |
RBST-094 |
||
|
– One sided RLC re-establishment |
FALSE |
Rel-5 |
RBST-095 |
|
|
– RB mapping info |
RBST-096 |
|||
|
– Information for each multiplexing option |
RBST-097 |
|||
|
– RLC logical channel mapping indicator |
Not Present |
RBST-098 |
||
|
– Number of uplink RLC logical channels |
1 |
RBST-099 |
||
|
– Uplink transport channel type |
DCH |
RBST-100 |
||
|
– UL Transport channel identity |
1 |
RBST-101 |
||
|
– Logical channel identity |
Not Present |
RBST-102 |
||
|
– CHOICE RLC size list |
Configured |
RBST-103 |
||
|
– MAC logical channel priority |
7 |
RBST-104 |
||
|
– Downlink RLC logical channel info |
RBST-105 |
|||
|
– Number of downlink RLC logical channels |
1 |
RBST-106 |
||
|
– Downlink transport channel type |
DCH |
RBST-107 |
||
|
– DL DCH Transport channel identity |
6 |
RBST-108 |
||
|
– DL DSCH Transport channel identity |
Not Present |
RBST-109 |
||
|
– Logical channel identity |
Not Present |
RBST-110 |
||
|
– RB identity |
A6, A7, A8, A9 |
20 |
RBST-111 |
|
|
– PDCP info |
Not present |
RBST-112 |
||
|
– CHOICE RLC info type |
RLC info |
RBST-113 |
||
|
– CHOICE Uplink RLC mode |
AM RLC |
RBST-114 |
||
|
– Transmission RLC discard |
RBST-115 |
|||
|
– CHOICE SDU discard mode |
No Discard |
RBST-116 |
||
|
– MAX_DAT |
15 |
RBST-117 |
||
|
– Transmission window size |
Selected with Total RLC AM Buffer Size |
RBST-118 |
||
|
– Timer_RST |
500 |
RBST-119 |
||
|
– Max_RST |
4 |
RBST-120 |
||
|
– Polling info |
RBST-121 |
|||
|
– Timer_poll_prohibit |
400 |
RBST-122 |
||
|
– Timer_poll |
400 |
RBST-123 |
||
|
– Poll_PDU |
Not Present |
RBST-124 |
||
|
– Poll_SDU |
1 |
RBST-125 |
||
|
– Last transmission PDU poll |
TRUE |
RBST-126 |
||
|
– Last retransmission PDU poll |
TRUE |
RBST-127 |
||
|
– Poll_Windows |
99 |
RBST-128 |
||
|
– Timer_poll_periodic |
Not Present |
RBST-129 |
||
|
– CHOICE Downlink RLC mode |
AM RLC |
RBST-130 |
||
|
– DL RLC PDU size |
A6 |
1280 bits |
Rel-5 |
RBST-131 |
|
– DL RLC PDU size |
A7 |
2880 bits |
Rel-5 |
RBST-132 |
|
– DL RLC PDU size |
A8 |
3840 bits |
Rel-5 |
RBST-133 |
|
– DL RLC PDU size |
A9 |
336 bits |
Rel-5 |
RBST-134 |
|
– In-sequence delivery |
A6, A7, A8, A9 |
TRUE |
RBST-135 |
|
|
– Receiving window size |
Selected with Total RLC AM Buffer Size |
RBST-136 |
||
|
– Downlink RLC status info |
RBST-137 |
|||
|
– Timer_status_prohibit |
330 |
RBST-138 |
||
|
– Timer_EPC |
Not Present |
RBST-139 |
||
|
– Missing PDU indicator |
TRUE |
RBST-140 |
||
|
– Timer_STATUS_periodic |
Not Present |
RBST-141 |
||
|
– One sided RLC re-establishment |
FALSE |
Rel-5 |
RBST-142 |
|
|
– RB mapping info |
RBST-143 |
|||
|
– Information for each multiplexing option |
2 RBMuxOptions |
RBST-144 |
||
|
– RLC logical channel mapping indicator |
Not Present |
RBST-145 |
||
|
– Number of uplink RLC logical channels |
1 |
RBST-146 |
||
|
– Uplink transport channel type |
DCH |
RBST-147 |
||
|
– UL Transport channel identity |
1 |
RBST-148 |
||
|
– Logical channel identity |
Not Present |
RBST-149 |
||
|
– CHOICE RLC size list |
Configured |
RBST-150 |
||
|
– MAC logical channel priority |
8 |
RBST-151 |
||
|
– Downlink RLC logical channel info |
RBST-152 |
|||
|
– Number of downlink RLC logical channels |
1 |
RBST-153 |
||
|
– Downlink transport channel type |
DCH |
RBST-154 |
||
|
– DL DCH Transport channel identity |
6 |
RBST-155 |
||
|
– DL DSCH Transport channel identity |
Not Present |
RBST-156 |
||
|
– Logical channel identity |
Not Present |
RBST-157 |
||
|
– RLC logical channel mapping indicator |
Not Present |
RBST-158 |
||
|
– Number of uplink RLC logical channels |
1 |
RBST-159 |
||
|
– Uplink transport channel type |
RACH |
RBST-160 |
||
|
– UL Transport channel identity |
Not Present |
RBST-161 |
||
|
– Logical channel identity |
7 |
RBST-162 |
||
|
– CHOICE RLC size list |
Explicit list |
RBST-163 |
||
|
– RLC size index |
Reference to clause 6 Parameter Set |
RBST-164 |
||
|
– MAC logical channel priority |
8 |
RBST-165 |
||
|
– Downlink RLC logical channel info |
RBST-166 |
|||
|
– Number of downlink RLC logical channels |
1 |
RBST-167 |
||
|
– Downlink transport channel type |
FACH |
RBST-168 |
||
|
– DL DCH Transport channel identity |
Not Present |
RBST-169 |
||
|
– DL DSCH Transport channel identity |
Not Present |
RBST-170 |
||
|
– Logical channel identity |
7 |
RBST-171 |
||
|
RB information to reconfigure list |
A1, A3, A4, A5, A6, A7, A8, A9 |
Not Present |
Rel-6 |
RBST-172 |
|
RB information to be affected list |
Not Present |
RBST-173 |
||
|
Downlink counter synchronization info |
Not Present |
RBST-174 |
||
|
PDCP ROHC target mode |
Not Present |
Rel-5 |
RBST-175 |
|
|
UL Transport channel information for all transport channels |
RBST-176 |
|||
|
– PRACH TFCS |
Not Present |
RBST-177 |
||
|
– CHOICE mode |
FDD |
RBST-178 |
||
|
– TFC subset |
Not Present |
RBST-179 |
||
|
– UL DCH TFCS |
RBST-180 |
|||
|
– CHOICE TFCI signalling |
Normal |
RBST-181 |
||
|
– TFCI Field 1 information |
RBST-182 |
|||
|
– CHOICE TFCS representation |
Complete reconfiguration |
RBST-183 |
||
|
– TFCS complete reconfigure information |
RBST-184 |
|||
|
– CHOICE CTFC Size |
2 bit CTFC |
RBST-185 |
||
|
– CTFC information |
4 TFCs |
RBST-186 |
||
|
– 2bit CTFC |
0 |
RBST-187 |
||
|
-Power offset Information |
RBST-188 |
|||
|
– CHOICE Gain Factors |
Computed Gain Factors |
RBST-189 |
||
|
– Reference TFC ID |
0 |
RBST-190 |
||
|
– CHOICE mode |
FDD |
RBST-191 |
||
|
– Power offset Pp-m |
Not Present |
RBST-192 |
||
|
– 2bit CTFC |
2 |
RBST-193 |
||
|
– Power offset Information |
RBST-194 |
|||
|
– CHOICE Gain Factors |
Computed Gain Factors |
RBST-195 |
||
|
– Reference TFC ID |
0 |
RBST-196 |
||
|
– CHOICE mode |
FDD |
RBST-197 |
||
|
– Power offset Pp-m |
Not Present |
RBST-198 |
||
|
– 2bit CTFC |
1 |
RBST-199 |
||
|
– Power offset Information |
RBST-200 |
|||
|
– CHOICE Gain Factors |
Computed Gain Factors |
RBST-201 |
||
|
– Reference TFC ID |
0 |
RBST-202 |
||
|
– CHOICE mode |
FDD |
RBST-203 |
||
|
– Power offset Pp-m |
Not Present |
RBST-204 |
||
|
– 2bit CTFC |
3 |
RBST-205 |
||
|
– Power offset Information |
RBST-206 |
|||
|
– CHOICE Gain Factors |
Signalled Gain Factors |
RBST-207 |
||
|
– CHOICE mode |
FDD |
RBST-208 |
||
|
– Gain factor ßc |
8 |
RBST-209 |
||
|
– Gain factor ßd |
15 |
RBST-210 |
||
|
– Reference TFC ID |
0 |
RBST-211 |
||
|
– CHOICE mode |
FDD |
RBST-212 |
||
|
– Power offset Pp-m |
Not Present |
RBST-213 |
||
|
Deleted UL TrCH information list |
Not Present |
RBST-214 |
||
|
Added or Reconfigured TrCH information list |
A1 |
1 |
RBST-215 |
|
|
– Added or Reconfigured UL TrCH information |
RBST-216 |
|||
|
– Uplink transport channel type |
DCH |
RBST-217 |
||
|
– UL Transport channel identity |
1 |
RBST-218 |
||
|
– TFS |
RBST-219 |
|||
|
– CHOICE Transport channel type |
Dedicated transport channels |
RBST-220 |
||
|
– Dynamic Transport Format Information |
RBST-221 |
|||
|
– RLC size |
244 bits |
RBST-222 |
||
|
– Number of TBs and TTI List |
2 |
RBST-223 |
||
|
– Transmission Time Interval |
Not Present |
RBST-224 |
||
|
– Number of Transport blocks |
0 |
RBST-225 |
||
|
– Transmission Time Interval |
Not Present |
RBST-226 |
||
|
– Number of Transport blocks |
1 |
RBST-227 |
||
|
– CHOICE Logical channel List |
ALL |
RBST-228 |
||
|
– Semi-static Transport Format Information |
RBST-229 |
|||
|
– Transmission time interval |
20 |
RBST-230 |
||
|
– Type of channel coding |
Convolutional |
RBST-231 |
||
|
– Coding Rate |
1/3 |
RBST-232 |
||
|
– Rate matching attribute |
256 |
RBST-233 |
||
|
– CRC size |
16 |
RBST-234 |
||
|
Added or Reconfigured TrCH information list |
A3, A4, A5, A6, A7, A8, A9 |
1 |
RBST-235 |
|
|
– Added or Reconfigured UL TrCH information |
RBST-236 |
|||
|
– Uplink transport channel type |
DCH |
RBST-237 |
||
|
– UL Transport channel identity |
1 |
RBST-238 |
||
|
– TFS |
RBST-239 |
|||
|
– CHOICE Transport channel type |
Dedicated transport channels |
RBST-240 |
||
|
– Dynamic Transport Format Information |
RBST-241 |
|||
|
– RLC size |
240 bits |
RBST-242 |
||
|
– Number of TBs and TTI List |
2 |
RBST-243 |
||
|
– Transmission Time Interval |
Not Present |
RBST-244 |
||
|
– Number of Transport blocks |
0 |
RBST-245 |
||
|
– Transmission Time Interval |
Not Present |
RBST-246 |
||
|
– Number of Transport blocks |
1 |
RBST-247 |
||
|
– CHOICE Logical channel List |
ALL |
RBST-248 |
||
|
– Semi-static Transport Format Information |
RBST-249 |
|||
|
– Transmission time interval |
20 |
RBST-250 |
||
|
– Type of channel coding |
Convolutional |
RBST-251 |
||
|
– Coding Rate |
1/3 |
RBST-252 |
||
|
– Rate matching attribute |
256 |
RBST-253 |
||
|
– CRC size |
16 |
RBST-254 |
||
|
CHOICE mode |
A1, A3, A4, A5, A6, A7, A8 |
Not Present |
RBST-255 |
|
|
DL Transport channel information common for all transport channel |
RBST-256 |
|||
|
– SCCPCH TFCS |
Not Present |
RBST-257 |
||
|
– CHOICE mode |
FDD |
RBST-258 |
||
|
– CHOICE DL parameters |
Same as UL |
RBST-259 |
||
|
Deleted DL TrCH information list |
Not Present |
RBST-260 |
||
|
CHOICE mode |
A9 |
Not Present |
RBST-261 |
|
|
DL Transport channel information common for all transport channel |
RBST-262 |
|||
|
– SCCPCH TFCS |
Not Present |
RBST-263 |
||
|
– CHOICE mode |
FDD |
RBST-264 |
||
|
– CHOICE DL parameters |
DL DCH TFCS |
RBST-265 |
||
|
– DL DCH TFCS |
RBST-266 |
|||
|
– CHOICE TFCI signalling |
Normal |
RBST-267 |
||
|
– TFCI Field 1 information |
RBST-268 |
|||
|
– CHOICE TFCS representation |
Complete reconfiguration |
RBST-269 |
||
|
– TFCS complete reconfigure information |
RBST-270 |
|||
|
– CHOICE CTFC Size |
4 bit CTFC |
RBST-271 |
||
|
– CTFC information |
6 TFCs |
RBST-272 |
||
|
– 4bit CTFC |
0 |
RBST-273 |
||
|
– Power offset Information |
RBST-274 |
|||
|
– CHOICE Gain Factors |
Computed Gain Factors |
RBST-275 |
||
|
– Reference TFC ID |
0 |
RBST-276 |
||
|
– CHOICE mode |
FDD |
RBST-277 |
||
|
– Power offset Pp-m |
Not Present |
RBST-278 |
||
|
– 4bit CTFC |
3 |
RBST-279 |
||
|
– Power offset Information |
RBST-280 |
|||
|
– CHOICE Gain Factors |
Computed Gain Factors |
RBST-281 |
||
|
– Reference TFC ID |
0 |
RBST-282 |
||
|
– CHOICE mode |
FDD |
RBST-283 |
||
|
– Power offset Pp-m |
Not Present |
RBST-284 |
||
|
– 4bit CTFC |
1 |
RBST-285 |
||
|
– Power offset Information |
RBST-286 |
|||
|
– CHOICE Gain Factors |
Computed Gain Factors |
RBST-287 |
||
|
– Reference TFC ID |
0 |
RBST-288 |
||
|
– CHOICE mode |
FDD |
RBST-289 |
||
|
– Power offset Pp-m |
Not Present |
RBST-290 |
||
|
– 4bit CTFC |
4 |
RBST-291 |
||
|
– Power offset Information |
RBST-292 |
|||
|
– CHOICE Gain Factors |
Computed Gain Factors |
RBST-293 |
||
|
– Reference TFC ID |
0 |
RBST-294 |
||
|
– CHOICE mode |
FDD |
RBST-295 |
||
|
– Power offset Pp-m |
Not Present |
RBST-296 |
||
|
– 4bit CTFC |
2 |
RBST-297 |
||
|
– Power offset Information |
RBST-298 |
|||
|
– CHOICE Gain Factors |
Computed Gain Factors |
RBST-299 |
||
|
– Reference TFC ID |
0 |
RBST-300 |
||
|
– CHOICE mode |
FDD |
RBST-301 |
||
|
– Power offset Pp-m |
Not Present |
RBST-302 |
||
|
– 4bit CTFC |
5 |
RBST-303 |
||
|
– Power offset Information |
RBST-304 |
|||
|
– CHOICE Gain Factors |
Signalled Gain Factors |
RBST-305 |
||
|
– CHOICE mode |
FDD |
RBST-306 |
||
|
– Gain factor ßc |
8 |
RBST-307 |
||
|
– Gain factor ßd |
15 |
RBST-308 |
||
|
– Reference TFC ID |
0 |
RBST-309 |
||
|
– CHOICE mode |
FDD |
RBST-310 |
||
|
– Power offset Pp-m |
Not Present |
RBST-311 |
||
|
Deleted DL TrCH information list |
Not Present |
RBST-312 |
||
|
Added or Reconfigured TrCH information list |
A1 |
1 |
RBST-313 |
|
|
– Added or Reconfigured DL TrCH information |
RBST-314 |
|||
|
– Downlink transport channel type |
DCH |
RBST-315 |
||
|
– DL Transport channel identity |
6 |
RBST-316 |
||
|
– CHOICE DL parameters |
Same as UL |
RBST-317 |
||
|
– Uplink transport channel type |
DCH |
RBST-318 |
||
|
– UL TrCH identity |
1 |
RBST-319 |
||
|
– DCH quality target |
RBST-320 |
|||
|
– BLER Quality value |
-20 (-2.0) |
RBST-321 |
||
|
Added or Reconfigured TrCH information list |
A3, A6 |
1 |
RBST-322 |
|
|
– Added or Reconfigured DL TrCH information |
RBST-323 |
|||
|
– Downlink transport channel type |
DCH |
RBST-324 |
||
|
– DL Transport channel identity |
6 |
RBST-325 |
||
|
– CHOICE DL parameters |
Explicit |
RBST-326 |
||
|
– TFS |
RBST-327 |
|||
|
– CHOICE Transport channel type |
Dedicated transport channels |
RBST-328 |
||
|
– Dynamic transport format information |
RBST-329 |
|||
|
– RLC Size |
1280 bits |
RBST-330 |
||
|
– Number of TBs and TTI List |
2 |
RBST-331 |
||
|
– Transmission Time Interval |
Not Present |
RBST-332 |
||
|
– Number of Transport blocks |
0 |
RBST-333 |
||
|
– Transmission Time Interval |
Not Present |
RBST-334 |
||
|
– Number of Transport blocks |
1 |
RBST-335 |
||
|
– CHOICE Logical channel list |
ALL |
RBST-336 |
||
|
– Semi-static Transport Format information |
RBST-337 |
|||
|
– Transmission time interval |
20 |
RBST-338 |
||
|
– Type of channel coding |
Turbo |
RBST-339 |
||
|
– Rate matching attribute |
256 |
RBST-340 |
||
|
– CRC size |
16 |
RBST-341 |
||
|
– DCH quality target |
RBST-342 |
|||
|
– BLER Quality value |
-20 (-2.0) |
RBST-343 |
||
|
Added or Reconfigured TrCH information list |
A4, A7 |
1 |
RBST-344 |
|
|
– Added or Reconfigured DL TrCH information |
RBST-345 |
|||
|
– Downlink transport channel type |
DCH |
RBST-346 |
||
|
– DL Transport channel identity |
6 |
RBST-347 |
||
|
– CHOICE DL parameters |
Explicit |
RBST-348 |
||
|
– TFS |
RBST-349 |
|||
|
– CHOICE Transport channel type |
Dedicated transport channels |
RBST-350 |
||
|
– Dynamic transport format information |
RBST-351 |
|||
|
– RLC Size |
2880 bits |
RBST-352 |
||
|
– Number of TBs and TTI List |
2 |
RBST-353 |
||
|
– Transmission Time Interval |
Not Present |
RBST-354 |
||
|
– Number of Transport blocks |
0 |
RBST-355 |
||
|
– Transmission Time Interval |
Not Present |
RBST-356 |
||
|
– Number of Transport blocks |
1 |
RBST-357 |
||
|
– CHOICE Logical channel list |
ALL |
RBST-358 |
||
|
– Semi-static Transport Format information |
RBST-359 |
|||
|
– Transmission time interval |
20 |
RBST-360 |
||
|
– Type of channel coding |
Turbo |
RBST-361 |
||
|
– Rate matching attribute |
256 |
RBST-362 |
||
|
– CRC size |
16 |
RBST-363 |
||
|
– DCH quality target |
RBST-364 |
|||
|
– BLER Quality value |
-20 (-2.0) |
RBST-365 |
||
|
Added or Reconfigured TrCH information list |
A5, A8 |
1 |
RBST-366 |
|
|
– Added or Reconfigured DL TrCH information |
RBST-367 |
|||
|
– Downlink transport channel type |
DCH |
RBST-368 |
||
|
– DL Transport channel identity |
6 |
RBST-369 |
||
|
– CHOICE DL parameters |
Explicit |
RBST-370 |
||
|
– TFS |
RBST-371 |
|||
|
– CHOICE Transport channel type |
Dedicated transport channels |
RBST-372 |
||
|
– Dynamic transport format information |
RBST-373 |
|||
|
– RLC Size |
3840 bits |
RBST-374 |
||
|
– Number of TBs and TTI List |
2 |
RBST-375 |
||
|
– Transmission Time Interval |
Not Present |
RBST-376 |
||
|
– Number of Transport blocks |
0 |
RBST-377 |
||
|
– Transmission Time Interval |
Not Present |
RBST-378 |
||
|
– Number of Transport blocks |
1 |
RBST-379 |
||
|
– CHOICE Logical channel list |
ALL |
RBST-380 |
||
|
– Semi-static Transport Format information |
RBST-381 |
|||
|
– Transmission time interval |
10 |
RBST-382 |
||
|
– Type of channel coding |
Turbo |
RBST-383 |
||
|
– Rate matching attribute |
256 |
RBST-384 |
||
|
– CRC size |
16 |
RBST-385 |
||
|
– DCH quality target |
RBST-386 |
|||
|
– BLER Quality value |
-20 (-2.0) |
RBST-387 |
||
|
Added or Reconfigured TrCH information list |
A9 |
1 |
RBST-388 |
|
|
– Added or Reconfigured DL TrCH information |
RBST-389 |
|||
|
– Downlink transport channel type |
DCH |
RBST-390 |
||
|
– DL Transport channel identity |
6 |
RBST-391 |
||
|
– CHOICE DL parameters |
Explicit |
RBST-392 |
||
|
– TFS |
RBST-393 |
|||
|
– CHOICE Transport channel type |
Dedicated transport channels |
RBST-394 |
||
|
– Dynamic transport format information |
RBST-395 |
|||
|
– RLC Size |
336 bits |
RBST-396 |
||
|
– Number of TBs and TTI List |
3 |
RBST-397 |
||
|
– Transmission Time Interval |
Not Present |
RBST-398 |
||
|
– Number of Transport blocks |
0 |
RBST-399 |
||
|
– Transmission Time Interval |
Not Present |
RBST-400 |
||
|
– Number of Transport blocks |
1 |
RBST-401 |
||
|
– Transmission Time Interval |
Not Present |
RBST-402 |
||
|
– Number of Transport blocks |
4 |
RBST-403 |
||
|
– CHOICE Logical channel list |
ALL |
RBST-404 |
||
|
– Semi-static Transport Format information |
RBST-405 |
|||
|
– Transmission time interval |
20 |
RBST-406 |
||
|
– Type of channel coding |
Turbo |
RBST-407 |
||
|
– Rate matching attribute |
143 |
RBST-408 |
||
|
– CRC size |
16 |
RBST-409 |
||
|
– DCH quality target |
RBST-410 |
|||
|
– BLER Quality value |
-20 (-2.0) |
RBST-411 |
||
|
Frequency info |
A1, A3, A4, A5, A6, A7, A8, A9 |
Not Present |
RBST-412 |
|
|
Multi-frequency Info |
Not Present |
Rel-7 |
RBST-413 |
|
|
DTX-DRX timing information |
Not Present |
Rel-7 |
RBST-414 |
|
|
DRX Information |
Not Present |
Rel-7 |
RBST-415 |
|
|
HS-SCCH less Information |
Not Present |
Rel-7 |
RBST-416 |
|
|
MIMO parameters |
Not Present |
Rel-7 |
RBST-417 |
|
|
Maximum allowed UL TX power |
33dBm |
RBST-418 |
||
|
CHOICE channel requirement |
Uplink DPCH info |
Rel-5 and earlier |
RBST-419 |
|
|
Uplink DPCH info |
Rel-6 |
RBST-420 |
||
|
– Uplink DPCH power control info |
RBST-421 |
|||
|
– CHOICE mode |
FDD |
RBST-422 |
||
|
– DPCCH power offset |
-40 (-80dB) IE value will have no effect on the UE UL power when closed loop power control is active |
RBST-423 |
||
|
– PC Preamble |
1 frame |
RBST-424 |
||
|
– SRB delay |
7 frames |
RBST-425 |
||
|
– Power Control Algorithm |
Algorithm1 |
RBST-426 |
||
|
– TPC step size |
0 (1dB) |
RBST-427 |
||
|
– ACK |
Not Present |
Rel-5 |
RBST-428 |
|
|
– NACK |
Not Present |
Rel-5 |
RBST-429 |
|
|
– Ack-Nack repetition factor |
Not Present |
Rel-5 |
RBST-430 |
|
|
– CHOICE mode |
FDD |
RBST-431 |
||
|
– Scrambling code type |
Long |
RBST-432 |
||
|
– Scrambling code number |
0 (0 to 16777215) |
RBST-433 |
||
|
– Number of DPDCH |
1 |
RBST-434 |
||
|
– spreading factor |
A1, A3, A4, A5, A6, A7, A8, A9 |
64 |
RBST-435 |
|
|
– TFCI existence |
A1, A3, A4, A5, A6, A7, A8, A9 |
TRUE |
RBST-436 |
|
|
– Number of FBI bit |
Not Present(0) |
RBST-437 |
||
|
– Puncturing Limit |
1 |
RBST-438 |
||
|
CHOICE Mode |
FDD |
R99 and Rel-4 only |
RBST-439 |
|
|
– Downlink PDSCH information |
Not Present |
R99 and Rel-4 only |
RBST-440 |
|
|
E-DCH Info |
Not Present |
Rel-6 |
RBST-441 |
|
|
Downlink HS-PDSCH Information |
Not Present |
Rel-5 |
RBST-442 |
|
|
Downlink information common for all radio links |
RBST-443 |
|||
|
– Downlink DPCH info common for all RL |
RBST-444 |
|||
|
– Timing indicator |
Maintain |
RBST-445 |
||
|
– CFN-targetSFN frame offset |
Not Present |
RBST-446 |
||
|
– Downlink DPCH power control information |
RBST-447 |
|||
|
– CHOICE mode |
FDD |
RBST-448 |
||
|
– DPC mode |
0 (single) |
RBST-449 |
||
|
– CHOICE mode |
FDD |
RBST-450 |
||
|
– Power offset PPilot-DPDCH |
0 |
RBST-451 |
||
|
– DL rate matching restriction information |
Not Present |
RBST-452 |
||
|
– Spreading factor |
A1 |
128 |
RBST-453 |
|
|
– Fixed or Flexible Position |
Fixed |
RBST-454 |
||
|
– TFCI existence |
TRUE |
RBST-455 |
||
|
– CHOICE SF |
128 |
RBST-456 |
||
|
– Number of bits for Pilot bits |
8 |
RBST-457 |
||
|
– Spreading factor |
A3, A6, A9 |
32 |
RBST-458 |
|
|
– Fixed or Flexible Position |
Fixed |
RBST-459 |
||
|
– TFCI existence |
TRUE |
RBST-460 |
||
|
– CHOICE SF |
32 |
RBST-461 |
||
|
– Spreading factor |
A4, A7 |
16 |
RBST-462 |
|
|
– Fixed or Flexible Position |
Fixed |
RBST-463 |
||
|
– TFCI existence |
TRUE |
RBST-464 |
||
|
– CHOICE SF |
16 |
RBST-465 |
||
|
– Spreading factor |
A5, A8 |
8 |
RBST-466 |
|
|
– Fixed or Flexible Position |
Fixed |
RBST-467 |
||
|
– TFCI existence |
TRUE |
RBST-468 |
||
|
– CHOICE SF |
8 |
RBST-469 |
||
|
– CHOICE mode |
A1, A3, A4, A5, A6, A7, A8, A9 |
FDD |
RBST-470 |
|
|
– DPCH compressed mode info |
Not Present |
RBST-471 |
||
|
– TX Diversity mode |
None |
RBST-472 |
||
|
– SSDT information |
Not Present |
R99 and Rel-4 only |
RBST-473 |
|
|
– Default DPCH Offset Value |
Not Present |
RBST-474 |
||
|
– MAC-hs reset indicator |
Not Present |
Rel-5 |
RBST-475 |
|
|
Downlink information per radio link list |
RBST-476 |
|||
|
– Downlink information for each radio link |
RBST-477 |
|||
|
– CHOICE mode |
FDD |
RBST-478 |
||
|
– Primary CPICH info |
RBST-479 |
|||
|
– Primary scrambling code |
Reference to clause 6.1 "Default settings (FDD)" |
RBST-480 |
||
|
– PDSCH with SHO DCH info |
Not Present |
R99 and Rel-4 only |
RBST-481 |
|
|
– PDSCH code mapping |
Not Present |
R99 and Rel-4 only |
RBST-482 |
|
|
– Serving HS-DSCH radio link indicator |
FALSE |
Rel-5 |
RBST-483 |
|
|
– Downlink DPCH info for each RL |
RBST-484 |
|||
|
– CHOICE mode |
FDD |
RBST-485 |
||
|
– Primary CPICH usage for channel estimation |
Primary CPICH may be used |
RBST-486 |
||
|
– DPCH frame offset |
Set to value Default DPCH Offset Value (as currently stored in SS) mod 38 400 |
RBST-487 |
||
|
– Secondary CPICH info |
Not Present |
RBST-488 |
||
|
– DL channelisation code |
RBST-489 |
|||
|
– Secondary scrambling code |
Not Present |
RBST-490 |
||
|
– Spreading factor |
A1 |
128 |
RBST-491 |
|
|
– Code number |
96 |
RBST-492 |
||
|
– Spreading factor |
A3, A6, A9 |
32 |
RBST-493 |
|
|
– Code number |
24 |
RBST-494 |
||
|
– Spreading factor |
A4, A7 |
16 |
RBST-495 |
|
|
– Code number |
12 |
RBST-496 |
||
|
– Spreading factor |
A5, A8 |
8 |
RBST-497 |
|
|
– Code number |
6 |
RBST-498 |
||
|
– Scrambling code change |
A1, A3, A4, A5, A6, A7, A8, A9 |
No change |
RBST-499 |
|
|
– TPC combination index |
0 |
RBST-500 |
||
|
– SSDT Cell Identity |
Not Present |
R99 and Rel-4 only |
RBST-501 |
|
|
– Closed loop timing adjustment mode |
Not Present |
RBST-502 |
||
|
– SCCPCH information for FACH |
Not Present |
R99 and Rel-4 only |
RBST-503 |
|
|
MBMS PL Service Restriction Information |
Not Present |
Rel-6 |
RBST-504 |
|
Condition |
Explanation |
Version |
|
A1 |
This IE is needed for "UE supports CS RAB for Test Loop Mode1 RMC 12.2/12.2 (TM)" |
|
|
A2 |
Not used |
|
|
A3 |
This IE is needed for "UE supports CS RAB for Test Loop Mode1 AMC 12.2/64 (AM)" |
|
|
A4 |
This IE is needed for "UE supports CS RAB for Test Loop Mode1 AMC 12.2/144 (AM)" |
|
|
A5 |
This IE is needed for "UE supports CS RAB for Test Loop Mode1 AMC 12.2/384 (AM)" |
|
|
A6 |
This IE is needed for "UE supports PS RAB for Test Loop Mode1 AMC 12.2/64 (AM)" |
|
|
A7 |
This IE is needed for "UE supports PS RAB for Test Loop Mode1 AMC 12.2/144 (AM)" |
|
|
A8 |
This IE is needed for "UE supports PS RAB for Test Loop Mode1 AMC 12.2/384 (AM)" |
|
|
A9 |
This IE is needed for "UE supports PS RAB for Test Loop Mode1 AMC 12.2/64(Channel2) (AM)" |
Contents of RADIO BEARER SETUP message: AM or UM (UE supports PS RAB only)
|
Information Element |
Value/remark |
Version |
Index |
|---|---|---|---|
|
Message Type |
RBSP-001 |
||
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
RBSP-002 |
|
|
Integrity check info |
RBSP-003 |
||
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
RBSP-004 |
|
|
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
RBSP-005 |
|
|
Integrity protection mode info |
Not Present |
RBSP-006 |
|
|
Ciphering mode info |
Not Present |
RBSP-007 |
|
|
Activation time |
(256+CFN-(CFN MOD 8 + 8))MOD 256 |
RBSP-008 |
|
|
New U-RNTI |
Not Present |
RBSP-009 |
|
|
New C-RNTI |
Not Present |
RBSP-010 |
|
|
New DSCH-RNTI |
Not Present |
R99 and Rel-4 only |
RBSP-011 |
|
New H-RNTI |
Not Present |
Rel-5 |
RBSP-012 |
|
New Primary E-RNTI |
Not Present |
Rel-6 |
RBSP-013 |
|
New Secondary E-RNTI |
Not Present |
Rel-6 |
RBSP-014 |
|
RRC State indicator |
CELL_DCH |
RBSP-015 |
|
|
UTRAN DRX cycle length coefficient |
Not Present |
RBSP-016 |
|
|
CN information info |
Not Present |
RBSP-017 |
|
|
URA identity |
Not Present |
RBSP-018 |
|
|
CHOICE specification mode |
Complete specification |
Rel-6 |
RBSP-019 |
|
– Signalling RB information to setup |
Not Present |
RBSP-020 |
|
|
– RAB information for setup list |
RBSP-021 |
||
|
– RAB information for setup |
RBSP-022 |
||
|
– RAB info |
(AM DTCH for PS domain) |
RBSP-023 |
|
|
– RAB identity |
0000 0101B The first/ leftmost bit of the bit string contains the most significant bit of the RAB identity. |
RBSP-024 |
|
|
– CN domain identity |
PS domain |
RBSP-025 |
|
|
– NAS Synchronization Indicator |
Not Present |
RBSP-026 |
|
|
– Re-establishment timer |
useT315 |
RBSP-027 |
|
|
– RB information to setup |
RBSP-028 |
||
|
– RB identity |
20 |
RBSP-029 |
|
|
– PDCP info |
RBSP-030 |
||
|
– Support for lossless SRNS relocation |
FALSE |
RBSP-031 |
|
|
– Max PDCP SN window size |
Not present |
RBSP-032 |
|
|
– PDCP PDU header |
Absent |
RBSP-033 |
|
|
– Header compression information |
Not present |
RBSP-034 |
|
|
– CHOICE RLC info type |
RLC info |
RBSP-035 |
|
|
– CHOICE Uplink RLC mode |
AM RLC |
RBSP-036 |
|
|
– Transmission RLC discard |
RBSP-037 |
||
|
– CHOICE SDU discard mode |
No Discard |
RBSP-038 |
|
|
– MAX_DAT |
15 |
RBSP-039 |
|
|
– Transmission window size |
128 |
RBSP-040 |
|
|
– Timer_RST |
500 |
RBSP-041 |
|
|
– Max_RST |
4 |
RBSP-042 |
|
|
– Polling info |
RBSP-043 |
||
|
– Timer_poll_prohibit |
200 |
RBSP-044 |
|
|
– Timer_poll |
200 |
RBSP-045 |
|
|
– Poll_PDU |
Not Present |
RBSP-046 |
|
|
– Poll_SDU |
1 |
RBSP-047 |
|
|
– Last transmission PDU poll |
TRUE |
RBSP-048 |
|
|
– Last retransmission PDU poll |
TRUE |
RBSP-049 |
|
|
– Poll_Windows |
99 |
RBSP-050 |
|
|
– Timer_poll_periodic |
Not Present |
RBSP-051 |
|
|
– CHOICE Downlink RLC mode |
AM RLC |
RBSP-052 |
|
|
– DL RLC PDU size |
Reference to clause 6 Parameter Set |
Rel-5 |
RBSP-053 |
|
– In-sequence delivery |
TRUE |
RBSP-054 |
|
|
– Receiving window size |
128 |
RBSP-055 |
|
|
– Downlink RLC status info |
RBSP-056 |
||
|
– Timer_status_prohibit |
200 |
RBSP-057 |
|
|
– Timer_EPC |
Not Present |
RBSP-058 |
|
|
– Missing PDU indicator |
TRUE |
RBSP-059 |
|
|
– Timer_STATUS_periodic |
Not Present |
RBSP-060 |
|
|
– RB mapping info |
RBSP-061 |
||
|
– Information for each multiplexing option |
2 RBMuxOptions |
RBSP-062 |
|
|
– RLC logical channel mapping indicator |
Not Present |
RBSP-063 |
|
|
– Number of uplink RLC logical channels |
1 |
RBSP-064 |
|
|
– Uplink transport channel type |
DCH |
RBSP-065 |
|
|
– UL Transport channel identity |
1 |
RBSP-066 |
|
|
– Logical channel identity |
Not Present |
RBSP-067 |
|
|
– CHOICE RLC size list |
Configured |
RBSP-068 |
|
|
– MAC logical channel priority |
8 |
RBSP-069 |
|
|
– Downlink RLC logical channel info |
RBSP-070 |
||
|
– Number of downlink RLC logical channels |
1 |
RBSP-071 |
|
|
– Downlink transport channel type |
DCH |
RBSP-072 |
|
|
– DL DCH Transport channel identity |
6 |
RBSP-073 |
|
|
– DL DSCH Transport channel identity |
Not Present |
RBSP-074 |
|
|
– Logical channel identity |
Not Present |
RBSP-075 |
|
|
– RLC logical channel mapping indicator |
Not Present |
RBSP-076 |
|
|
– Number of uplink RLC logical channels |
1 |
RBSP-077 |
|
|
– Uplink transport channel type |
RACH |
RBSP-078 |
|
|
– UL Transport channel identity |
Not Present |
RBSP-079 |
|
|
– Logical channel identity |
7 |
RBSP-080 |
|
|
– CHOICE RLC size list |
Explicit list |
RBSP-081 |
|
|
– RLC size index |
Reference to clause 6 Parameter Set |
RBSP-082 |
|
|
– MAC logical channel priority |
8 |
RBSP-083 |
|
|
– Downlink RLC logical channel info |
RBSP-084 |
||
|
– Number of downlink RLC logical channels |
1 |
RBSP-085 |
|
|
– Downlink transport channel type |
FACH |
RBSP-086 |
|
|
– DL DCH Transport channel identity |
Not Present |
RBSP-087 |
|
|
– DL DSCH Transport channel identity |
Not Present |
RBSP-088 |
|
|
– Logical channel identity |
7 |
RBSP-089 |
|
|
RB information to reconfigure list |
Not Present |
Rel-6 |
RBSP-090 |
|
RB information to be affected list |
Not Present |
RBSP-091 |
|
|
Downlink counter synchronization info |
Not Present |
RBSP-092 |
|
|
UL Transport channel information for all transport channels |
RBSP-093 |
||
|
– PRACH TFCS |
Not Present |
RBSP-094 |
|
|
– CHOICE mode |
FDD |
RBSP-095 |
|
|
– TFC subset |
Not Present |
RBSP-096 |
|
|
– UL DCH TFCS |
RBSP-097 |
||
|
– CHOICE TFCI signalling |
Normal |
RBSP-098 |
|
|
– TFCI Field 1 information |
RBSP-099 |
||
|
– CHOICE TFCS representation |
Complete reconfiguration |
RBSP-100 |
|
|
– TFCS complete reconfigure information |
RBSP-101 |
||
|
– CHOICE CTFC Size |
Number of bits used must be enough to cover all combinations of CTFC from clause 6.10.2.4 Parameter Set. |
RBSP-102 |
|
|
– CTFC information |
This IE is repeated for TFC numbers and reference to clause 6.10.2.4 Parameter Set |
RBSP-103 |
|
|
– CTFC |
Reference to clause 6.10.2.4 Parameter Set |
RBSP-104 |
|
|
– Power offset information |
RBSP-105 |
||
|
– CHOICE Gain Factors |
Computed Gain Factors(The last TFC is set to Signalled Gain Factors) |
RBSP-106 |
|
|
– Gain factor βc |
11 (below 64 kbps) 9 (higher than 64 kbps) (Not Present if the CHOICE Gain Factors is set to Computed Gain Factors) |
RBSP-107 |
|
|
– Gain factor βd |
15 (Not Present if the CHOICE Gain Factors is set to Computed Gain Factors) |
RBSP-108 |
|
|
– Reference TFC ID |
0 |
RBSP-109 |
|
|
– CHOICE mode |
FDD |
RBSP-110 |
|
|
– Power offset P p-m |
Not Present |
RBSP-111 |
|
|
Deleted UL TrCH information list |
Not Present |
RBSP-112 |
|
|
Added or Reconfigured UL TrCH information list |
1 |
RBSP-113 |
|
|
Added or Reconfigured UL TrCH information |
1 DCH added, 1 DCH reconfigured |
RBSP-114 |
|
|
– Uplink transport channel type |
DCH |
RBSP-115 |
|
|
– UL Transport channel identity |
1 |
RBSP-116 |
|
|
– TFS |
RBSP-117 |
||
|
– CHOICE Transport channel type |
Dedicated transport channels |
RBSP-118 |
|
|
– Dynamic Transport format information |
RBSP-119 |
||
|
– RLC Size |
Reference to clause 6.10 Parameter Set |
RBSP-120 |
|
|
– Number of TBs and TTI List |
(This IE is repeated for TFI number.) |
RBSP-121 |
|
|
– Transmission Time Interval |
Not Present |
RBSP-122 |
|
|
– Number of Transport blocks |
Reference to clause 6.10 Parameter Set |
RBSP-123 |
|
|
– CHOICE Logical channel list |
All |
RBSP-124 |
|
|
– Semi-static Transport Format information |
RBSP-125 |
||
|
– Transmission time interval |
Reference to clause 6.10 Parameter Set |
RBSP-126 |
|
|
– Type of channel coding |
Reference to clause 6.10 Parameter Set |
RBSP-127 |
|
|
– Coding Rate |
Reference to clause 6.10 Parameter Set |
RBSP-128 |
|
|
– Rate matching attribute |
Reference to clause 6.10 Parameter Set |
RBSP-129 |
|
|
– CRC size |
Reference to clause 6.10 Parameter Set |
RBSP-130 |
|
|
– Uplink transport channel type |
DCH |
RBSP-131 |
|
|
– UL Transport channel identity |
5 |
RBSP-132 |
|
|
– TFS |
RBSP-133 |
||
|
– CHOICE Transport channel type |
Dedicated transport channels |
RBSP-134 |
|
|
– Dynamic Transport format information |
RBSP-135 |
||
|
– RLC Size |
Reference to clause 6.10 Parameter Set |
RBSP-136 |
|
|
– Number of TBs and TTI List |
(This IE is repeated for TFI number.) |
RBSP-137 |
|
|
– Transmission Time Interval |
Not Present |
RBSP-138 |
|
|
– Number of Transport blocks |
Reference to clause 6.10 Parameter Set |
RBSP-139 |
|
|
– CHOICE Logical channel list |
All |
RBSP-140 |
|
|
– Semi-static Transport Format information |
RBSP-141 |
||
|
– Transmission time interval |
Reference to clause 6.10 Parameter Set |
RBSP-142 |
|
|
– Type of channel coding |
Reference to clause 6.10 Parameter Set |
RBSP-143 |
|
|
– Coding Rate |
Reference to clause 6.10 Parameter Set |
RBSP-144 |
|
|
– Rate matching attribute |
Reference to clause 6.10 Parameter Set |
RBSP-145 |
|
|
– CRC size |
Reference to clause 6.10 Parameter Set |
RBSP-146 |
|
|
CHOICE mode |
Not Present |
RBSP-147 |
|
|
DL Transport channel information common for all transport channel |
RBSP-148 |
||
|
– SCCPCH TFCS |
Not Present |
RBSP-149 |
|
|
– CHOICE mode |
FDD |
RBSP-150 |
|
|
– CHOICE DL parameters |
Explicit |
RBSP-151 |
|
|
– DL DCH TFCS |
RBSP-152 |
||
|
– CHOICE TFCI Signalling |
Normal |
RBSP-153 |
|
|
– TFCI Field 1 Information |
RBSP-154 |
||
|
– CHOICE TFCS representation |
Complete reconfiguration |
RBSP-155 |
|
|
– TFCS complete reconfigure |
RBSP-156 |
||
|
– CHOICE CTFC Size |
Number of bits used must be enough to cover all combinations of CTFC from clause 6.10.2.4 Parameter Set. |
RBSP-157 |
|
|
– CTFC information |
This IE is repeated for TFC numbers and reference to clause 6.10.2.4 |
RBSP-158 |
|
|
– CTFC |
Reference to clause 6.10.2.4 Parameter Set |
RBSP-159 |
|
|
– Power offset information |
Not Present |
RBSP-160 |
|
|
Added or Reconfigured DL TrCH information list |
1 |
RBSP-161 |
|
|
Added or Reconfigured DL TrCH information |
2 TrCHs(DCH for DCCH and DCH for DTCH) |
RBSP-162 |
|
|
– Downlink transport channel type |
DCH |
RBSP-163 |
|
|
– DL Transport channel identity |
10 |
RBSP-164 |
|
|
– CHOICE DL parameters |
Same as UL |
RBSP-165 |
|
|
– Uplink transport channel type |
DCH |
RBSP-166 |
|
|
– UL TrCH identity |
5 |
RBSP-167 |
|
|
– DCH quality target |
RBSP-168 |
||
|
– BLER Quality value |
-20 (-2.0) |
RBSP-169 |
|
|
– Downlink transport channel type |
DCH |
RBSP-170 |
|
|
– DL Transport channel identity |
6 |
RBSP-171 |
|
|
– CHOICE DL parameters |
Explicit |
RBSP-172 |
|
|
– TFS |
RBSP-173 |
||
|
– CHOICE Transport channel type |
Dedicated transport channel |
RBSP-174 |
|
|
– Dynamic transport format information |
RBSP-175 |
||
|
– RLC Size |
Reference to clause 6.10 Parameter Set |
RBSP-176 |
|
|
– Number of TBs and TTI List |
(This IE is repeated for TFI number.) |
RBSP-177 |
|
|
– Dynamic transport format information |
RBSP-178 |
||
|
– Transmission Time Interval |
Not Present |
RBSP-179 |
|
|
– Number of Transport blocks |
Reference to clause 6.10 Parameter Set |
RBSP-180 |
|
|
– CHOICE Logical channel list |
All |
RBSP-181 |
|
|
– Semi-static Transport Format information |
RBSP-182 |
||
|
– Transmission time interval |
Reference to clause 6.10 Parameter Set |
RBSP-183 |
|
|
– Type of channel coding |
Reference to clause 6.10 Parameter Set |
RBSP-184 |
|
|
– Coding Rate |
Reference to clause 6.10 Parameter Set |
RBSP-185 |
|
|
– Rate matching attribute |
Reference to clause 6.10 Parameter Set |
RBSP-186 |
|
|
– CRC size |
Reference to clause 6.10 Parameter Set |
RBSP-187 |
|
|
– DCH quality target |
RBSP-188 |
||
|
– BLER Quality value |
-20 (-2.0) |
RBSP-189 |
|
|
Frequency info |
Not Present |
RBSP-190 |
|
|
Multi-frequency Info |
Not present |
Rel-7 |
RBSP-191 |
|
DTX-DRX timing information |
Not present |
Rel-7 |
RBSP-192 |
|
DRX Information |
Not present |
Rel-7 |
RBSP-193 |
|
HS-SCCH less Information |
Not present |
Rel-7 |
RBSP-194 |
|
MIMO parameters |
Not present |
Rel-7 |
RBSP-195 |
|
Maximum allowed UL TX power |
33dBm |
RBSP-196 |
|
|
CHOICE channel requirement |
Uplink DPCH info |
Rel-5 and earlier |
RBSP-197 |
|
Uplink DPCH info |
Rel-6 |
RBSP-198 |
|
|
– Uplink DPCH power control info |
RBSP-199 |
||
|
– CHOICE mode |
FDD |
RBSP-200 |
|
|
– DPCCH power offset |
-40 (-80dB) IE value will have no effect on the UE UL power when closed loop power control is active |
RBSP-201 |
|
|
– PC Preamble |
1 frame |
RBSP-202 |
|
|
– SRB delay |
7 frames |
RBSP-203 |
|
|
– Power Control Algorithm |
Algorithm1 |
RBSP-204 |
|
|
– TPC step size |
0 (1dB) |
RBSP-205 |
|
|
– ACK |
Not Present |
Rel-5 |
RBSP-206 |
|
– NACK |
Not Present |
Rel-5 |
RBSP-207 |
|
– Ack-Nack repetition factor |
Not Present |
Rel-5 |
RBSP-208 |
|
– CHOICE mode |
FDD |
RBSP-209 |
|
|
– Scrambling code type |
Long |
RBSP-210 |
|
|
– Scrambling code number |
0 (0 to 16777215) |
RBSP-211 |
|
|
– Number of DPDCH |
1 |
RBSP-212 |
|
|
– spreading factor |
64 |
RBSP-213 |
|
|
– TFCI existence |
TRUE |
RBSP-214 |
|
|
– Number of FBI bit |
Not Present(0) |
RBSP-215 |
|
|
– Puncturing Limit |
1 |
RBSP-216 |
|
|
CHOICE Mode |
FDD |
R99 and Rel-4 only |
RBSP-217 |
|
E-DCH Info |
Not Present |
Rel-6 |
RBSP-218 |
|
– Downlink PDSCH information |
Not Present |
R99 and Rel-4 only |
RBSP-219 |
|
Downlink HS-PDSCH Information |
Not Present |
Rel-5 |
RBSP-220 |
|
Downlink information common for all radio links |
RBSP-221 |
||
|
– Downlink DPCH info common for all RL |
RBSP-222 |
||
|
– Timing indicator |
Maintain |
RBSP-223 |
|
|
– CFN-targetSFN frame offset |
Not Present |
RBSP-224 |
|
|
– Downlink DPCH power control information |
RBSP-225 |
||
|
– CHOICE mode |
FDD |
RBSP-226 |
|
|
– DPC mode |
0 (single) |
RBSP-227 |
|
|
– CHOICE mode |
FDD |
RBSP-228 |
|
|
– Power offset PPilot-DPDCH |
0 |
RBSP-229 |
|
|
– DL rate matching restriction information |
Not Present |
RBSP-230 |
|
|
– Spreading factor |
Reference to clause 6.10 Parameter Set |
RBSP-231 |
|
|
– Fixed or Flexible Position |
Reference to clause 6.10 Parameter Set |
RBSP-232 |
|
|
– TFCI existence |
Reference to clause 6.10 Parameter Set |
RBSP-233 |
|
|
– CHOICE SF |
Reference to clause 6.10 Parameter Set |
RBSP-234 |
|
|
– CHOICE mode |
FDD |
RBSP-235 |
|
|
– DPCH compressed mode info |
Not Present |
RBSP-236 |
|
|
– TX Diversity mode |
None |
RBSP-237 |
|
|
– SSDT information |
Not Present |
R99 and Rel-4 only |
RBSP-238 |
|
– Default DPCH Offset Value |
Not Present |
RBSP-239 |
|
|
– MAC-hs reset indicator |
Not Present |
Rel-5 |
RBSP-240 |
|
– Post-verification period |
Not Present |
Rel-6 |
RBSP-241 |
|
Downlink information per radio link list |
RBSP-242 |
||
|
– Downlink information for each radio link |
RBSP-243 |
||
|
– CHOICE mode |
FDD |
RBSP-244 |
|
|
– Primary CPICH info |
RBSP-245 |
||
|
– Primary scrambling code |
Reference to clause 6.1 "Default settings (FDD)" |
RBSP-246 |
|
|
– PDSCH with SHO DCH info |
Not Present |
R99 and Rel-4 only |
RBSP-247 |
|
– PDSCH code mapping |
Not Present |
R99 and Rel-4 only |
RBSP-248 |
|
– Downlink DPCH info for each RL |
RBSP-249 |
||
|
– CHOICE mode |
FDD |
RBSP-250 |
|
|
– Primary CPICH usage for channel estimation |
Primary CPICH may be used |
RBSP-251 |
|
|
– DPCH frame offset |
Set to value Default DPCH Offset Value (as currently stored in SS) mod 38 400 |
RBSP-252 |
|
|
– Secondary CPICH info |
Not Present |
RBSP-253 |
|
|
– DL channelisation code |
RBSP-254 |
||
|
– Secondary scrambling code |
Not present |
RBSP-255 |
|
|
– Spreading factor |
Reference to clause 6.10 Parameter Set |
RBSP-256 |
|
|
– Code number |
Depends upon radio bearer used. |
RBSP-257 |
|
|
– Scrambling code change |
No change |
RBSP-258 |
|
|
– TPC combination index |
0 |
RBSP-259 |
|
|
– SSDT Cell Identity |
Not Present |
R99 and Rel-4 only |
RBSP-260 |
|
– Closed loop timing adjustment mode |
Not Present |
RBSP-261 |
|
|
– SCCPCH information for FACH |
Not Present |
R99 and Rel-4 only |
RBSP-262 |
|
MBMS PL Service Restriction Information |
Not Present |
Rel-6 |
RBSP-263 |
Contents of RADIO BEARER SETUP message: AM or UM (UE supports CS RAB for Test Loop Mode 2)
|
Information Element |
Value/remark |
Version |
Index |
|---|---|---|---|
|
Message Type |
RBSC-001 |
||
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
RBSC-002 |
|
|
Integrity check info |
RBSC-003 |
||
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
RBSC-004 |
|
|
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
RBSC-005 |
|
|
Integrity protection mode info |
Not Present |
RBSC-006 |
|
|
Ciphering mode info |
Not Present |
RBSC-007 |
|
|
Activation time |
(256+CFN-(CFN MOD 8 + 8))MOD 256 |
RBSC-008 |
|
|
New U-RNTI |
Not Present |
RBSC-009 |
|
|
New C-RNTI |
Not Present |
RBSC-010 |
|
|
New DSCH-RNTI |
Not Present |
R99 and Rel-4 only |
RBSC-011 |
|
New H-RNTI |
Not Present |
Rel-5 |
RBSC-012 |
|
New Primary E-RNTI |
Not Present |
Rel-6 |
RBSC-013 |
|
New Secondary E-RNTI |
Not Present |
Rel-6 |
RBSC-014 |
|
RRC State indicator |
CELL_DCH |
RBSC-015 |
|
|
UTRAN DRX cycle length coefficient |
Not Present |
RBSC-016 |
|
|
CN information info |
Not Present |
RBSC-017 |
|
|
URA identity |
Not Present |
RBSC-018 |
|
|
CHOICE specification mode |
Complete specification |
Rel-6 |
RBSC-019 |
|
Signalling RB information to setup |
Not Present |
RBSC-020 |
|
|
RAB information for setup list |
RBSC-021 |
||
|
– RAB information for setup |
RBSC-022 |
||
|
– RAB info |
RBSC-023 |
||
|
– RAB identity |
0000 0001B The first/ leftmost bit of the bit string contains the most significant bit of the RAB identity. |
RBSC-024 |
|
|
– CN domain identity |
CS domain |
RBSC-025 |
|
|
– NAS Synchronization Indicator |
Not Present |
RBSC-026 |
|
|
– Re-establishment timer |
UseT314 |
RBSC-027 |
|
|
– RB information to setup list |
RBSC-028 |
||
|
– RB information to setup |
RBSC-029 |
||
|
– RB identity |
10 |
RBSC-030 |
|
|
– PDCP info |
Not Present |
RBSC-031 |
|
|
– CHOICE RLC info type |
RLC info |
RBSC-032 |
|
|
– CHOICE Uplink RLC mode |
TM RLC |
RBSC-033 |
|
|
– Transmission RLC discard |
Not Present |
RBSC-034 |
|
|
– Segmentation indication |
FALSE |
RBSC-035 |
|
|
– CHOICE Downlink RLC mode |
TM RLC |
RBSC-036 |
|
|
– Segmentation indication |
FALSE |
RBSC-037 |
|
|
– RB mapping info |
RBSC-038 |
||
|
– Information for each multiplexing option |
RBSC-039 |
||
|
– RLC logical channel mapping indicator |
Not Present |
RBSC-040 |
|
|
– Number of uplink RLC logical channels |
1 |
RBSC-041 |
|
|
– Uplink transport channel type |
DCH |
RBSC-042 |
|
|
– UL Transport channel identity |
1 |
RBSC-043 |
|
|
– Logical channel identity |
Not Present |
RBSC-044 |
|
|
– CHOICE RLC size list |
Configured |
RBSC-045 |
|
|
– MAC logical channel priority |
7 |
RBSC-046 |
|
|
– Downlink RLC logical channel info |
RBSC-047 |
||
|
– Number of downlink RLC logical channels |
1 |
RBSC-048 |
|
|
– Downlink transport channel type |
DCH |
RBSC-049 |
|
|
– DL DCH Transport channel identity |
6 |
RBSC-050 |
|
|
– DL DSCH Transport channel identity |
Not Present |
RBSC-051 |
|
|
– Logical channel identity |
Not Present |
RBSC-052 |
|
|
RB information to reconfigure list |
Not Present |
Rel-6 |
RBSC-053 |
|
RB information to be affected list |
Not Present |
RBSC-054 |
|
|
Downlink counter synchronization info |
Not Present |
RBSC-055 |
|
|
UL Transport channel information for all transport channels |
RBSC-056 |
||
|
– PRACH TFCS |
Not Present |
RBSC-057 |
|
|
– CHOICE mode |
FDD |
RBSC-058 |
|
|
– TFC subset |
Not Present |
RBSC-059 |
|
|
– UL DCH TFCS |
RBSC-060 |
||
|
– CHOICE TFCI signalling |
Normal |
RBSC-061 |
|
|
– TFCI Field 1 information |
RBSC-062 |
||
|
– CHOICE TFCS representation |
Complete reconfiguration |
RBSC-063 |
|
|
– TFCS complete reconfigure information |
RBSC-064 |
||
|
– CHOICE CTFC Size |
2 bit CTFC |
RBSC-065 |
|
|
– CTFC information |
4 TFCs |
RBSC-066 |
|
|
– 2bit CTFC |
0 |
RBSC-067 |
|
|
– Power offset Information |
RBSC-068 |
||
|
– CHOICE Gain Factors |
Computed Gain Factors |
RBSC-069 |
|
|
– Reference TFC ID |
0 |
RBSC-070 |
|
|
– CHOICE mode |
FDD |
RBSC-071 |
|
|
– Power offset Pp-m |
Not Present |
RBSC-072 |
|
|
– 2bit CTFC |
2 |
RBSC-073 |
|
|
– Power offset Information |
RBSC-074 |
||
|
– CHOICE Gain Factors |
Computed Gain Factors |
RBSC-075 |
|
|
– Reference TFC ID |
0 |
RBSC-076 |
|
|
– CHOICE mode |
FDD |
RBSC-077 |
|
|
– Power offset Pp-m |
Not Present |
RBSC-078 |
|
|
– 2bit CTFC |
1 |
RBSC-079 |
|
|
– Power offset Information |
RBSC-080 |
||
|
– CHOICE Gain Factors |
Computed Gain Factors |
RBSC-081 |
|
|
– Reference TFC ID |
0 |
RBSC-082 |
|
|
– CHOICE mode |
FDD |
RBSC-083 |
|
|
– Power offset Pp-m |
Not Present |
RBSC-084 |
|
|
– 2bit CTFC |
3 |
RBSC-085 |
|
|
– Power offset Information |
RBSC-086 |
||
|
– CHOICE Gain Factors |
Signalled Gain Factors |
RBSC-087 |
|
|
– CHOICE mode |
FDD |
RBSC-088 |
|
|
– Gain factor ßc |
8 |
RBSC-089 |
|
|
– Gain factor ßd |
15 |
RBSC-090 |
|
|
– Reference TFC ID |
0 |
RBSC-091 |
|
|
– CHOICE mode |
FDD |
RBSC-092 |
|
|
– Power offset Pp-m |
Not Present |
RBSC-093 |
|
|
Deleted UL TrCH information list |
Not Present |
RBSC-094 |
|
|
Added or Reconfigured UL TrCH information list |
1 |
RBSC-095 |
|
|
– Added or Reconfigured UL TrCH information |
RBSC-096 |
||
|
– Uplink transport channel type |
DCH |
RBSC-097 |
|
|
– UL Transport channel identity |
1 |
RBSC-098 |
|
|
– TFS |
RBSC-099 |
||
|
– CHOICE Transport channel type |
Dedicated transport channels |
RBSC-100 |
|
|
– Dynamic Transport Format Information |
RBSC-101 |
||
|
– RLC size |
260 bits |
RBSC-102 |
|
|
– Number of TBs and TTI List |
2 |
RBSC-103 |
|
|
– Transmission Time Interval |
Not Present |
RBSC-104 |
|
|
– Number of Transport blocks |
0 |
RBSC-105 |
|
|
– Transmission Time Interval |
Not Present |
RBSC-106 |
|
|
– Number of Transport blocks |
1 |
RBSC-107 |
|
|
– CHOICE Logical channel List |
ALL |
RBSC-108 |
|
|
– Semi-static Transport Format Information |
RBSC-109 |
||
|
– Transmission time interval |
20 |
RBSC-110 |
|
|
– Type of channel coding |
Convolutional |
RBSC-111 |
|
|
– Coding Rate |
1/3 |
RBSC-112 |
|
|
– Rate matching attribute |
256 |
RBSC-113 |
|
|
– CRC size |
0 |
RBSC-114 |
|
|
CHOICE mode |
Not Present |
RBSC-115 |
|
|
DL Transport channel information common for all transport channel |
RBSC-116 |
||
|
– SCCPCH TFCS |
Not Present |
RBSC-117 |
|
|
– CHOICE mode |
FDD |
RBSC-118 |
|
|
– CHOICE DL parameters |
Same as UL |
RBSC-119 |
|
|
Deleted DL TrCH information list |
Not Present |
RBSC-120 |
|
|
Added or Reconfigured DL TrCH information list |
1 |
RBSC-121 |
|
|
– Added or Reconfigured DL TrCH information |
RBSC-122 |
||
|
– Downlink transport channel type |
DCH |
RBSC-123 |
|
|
– DL Transport channel identity |
6 |
RBSC-124 |
|
|
– CHOICE DL parameters |
RBSC-125 |
||
|
– CHOICE Transport channel type |
Dedicated transport channels |
RBSC-126 |
|
|
– Dynamic Transport Format Information |
RBSC-127 |
||
|
– RLC size |
244 bits |
RBSC-128 |
|
|
– Number of TBs and TTI List |
2 |
RBSC-129 |
|
|
– Transmission Time Interval |
Not Present |
RBSC-130 |
|
|
– Number of Transport blocks |
0 |
RBSC-131 |
|
|
– Transmission Time Interval |
Not Present |
RBSC-132 |
|
|
– Number of Transport blocks |
1 |
RBSC-133 |
|
|
– CHOICE Logical channel List |
ALL |
RBSC-134 |
|
|
– Semi-static Transport Format Information |
RBSC-135 |
||
|
– Transmission time interval |
20 |
RBSC-136 |
|
|
– Type of channel coding |
Convolutional |
RBSC-137 |
|
|
– Coding Rate |
1/3 |
RBSC-138 |
|
|
– Rate matching attribute |
256 |
RBSC-139 |
|
|
– CRC size |
16 |
RBSC-140 |
|
|
– DCH quality target |
RBSC-141 |
||
|
– BLER Quality value |
-20 (-2.0) |
RBSC-142 |
|
|
Frequency info |
Not Present |
RBSC-143 |
|
|
Multi-frequency Info |
Not present |
Rel-7 |
RBSC-144 |
|
DTX-DRX timing information |
Not present |
Rel-7 |
RBSC-145 |
|
DRX Information |
Not present |
Rel-7 |
RBSC-146 |
|
HS-SCCH less Information |
Not present |
Rel-7 |
RBSC-147 |
|
MIMO parameters |
Not present |
Rel-7 |
RBSC-148 |
|
Maximum allowed UL TX power |
33dBm |
RBSC-149 |
|
|
CHOICE channel requirement |
Uplink DPCH info |
Rel-5 and earlier |
RBSC-150 |
|
Uplink DPCH info |
Rel-6 |
RBSC-151 |
|
|
– Uplink DPCH power control info |
RBSC-152 |
||
|
– CHOICE mode |
FDD |
RBSC-153 |
|
|
– DPCCH power offset |
-40 (-80dB) IE value will have no effect on the UE UL power when closed loop power control is active |
RBSC-154 |
|
|
– PC Preamble |
1 frame |
RBSC-155 |
|
|
– SRB delay |
7 frames |
RBSC-156 |
|
|
– Power Control Algorithm |
Algorithm1 |
RBSC-157 |
|
|
– TPC step size |
0 (1dB) |
RBSC-158 |
|
|
– ACK |
Not Present |
Rel-5 |
RBSC-159 |
|
– NACK |
Not Present |
Rel-5 |
RBSC-160 |
|
– Ack-Nack repetition factor |
Not Present |
Rel-5 |
RBSC-161 |
|
– CHOICE mode |
FDD |
RBSC-162 |
|
|
– Scrambling code type |
Long |
RBSC-163 |
|
|
– Scrambling code number |
0 (0 to 16777215) |
RBSC-164 |
|
|
– Number of DPDCH |
1 |
RBSC-165 |
|
|
– spreading factor |
64 |
RBSC-166 |
|
|
– TFCI existence |
TRUE |
RBSC-167 |
|
|
– Number of FBI bit |
Not Present(0) |
RBSC-168 |
|
|
– Puncturing Limit |
1 |
RBSC-169 |
|
|
CHOICE Mode |
FDD |
R99 and Rel-4 only |
RBSC-170 |
|
– Downlink PDSCH information |
Not Present |
R99 and Rel-4 only |
RBSC-171 |
|
E-DCH Info |
Not Present |
Rel-6 |
RBSC-172 |
|
Downlink HS-PDSCH Information |
Not Present |
Rel-5 |
RBSC-173 |
|
Downlink information common for all radio links |
RBSC-174 |
||
|
– Downlink DPCH info common for all RL |
RBSC-175 |
||
|
– Timing indicator |
Maintain |
RBSC-176 |
|
|
– CFN-targetSFN frame offset |
Not Present |
RBSC-177 |
|
|
– Downlink DPCH power control information |
RBSC-178 |
||
|
– CHOICE mode |
FDD |
RBSC-179 |
|
|
– DPC mode |
0 (single) |
RBSC-180 |
|
|
– CHOICE mode |
FDD |
RBSC-181 |
|
|
– Power offset PPilot-DPDCH |
0 |
RBSC-182 |
|
|
– DL rate matching restriction information |
Not Present |
RBSC-183 |
|
|
– Spreading factor |
128 |
RBSC-184 |
|
|
– Fixed or Flexible Position |
Fixed |
RBSC-185 |
|
|
– TFCI existence |
TRUE |
RBSC-186 |
|
|
– CHOICE SF |
128 |
RBSC-187 |
|
|
– Number of bits for Pilot bits |
8 |
RBSC-188 |
|
|
– CHOICE mode |
FDD |
RBSC-189 |
|
|
– DPCH compressed mode info |
Not Present |
RBSC-190 |
|
|
– TX Diversity mode |
None |
RBSC-191 |
|
|
– SSDT information |
Not Present |
R99 and Rel-4 only |
RBSC-192 |
|
– Default DPCH Offset Value |
Not Present |
RBSC-193 |
|
|
– MAC-hs reset indicator |
Not Present |
Rel-5 |
RBSC-194 |
|
– Post-verification period |
Not Present |
Rel-6 |
RBSC-195 |
|
Downlink information for per radio link list |
RBSC-196 |
||
|
– Downlink information for each radio link |
RBSC-197 |
||
|
– CHOICE mode |
FDD |
RBSC-198 |
|
|
– Primary CPICH info |
RBSC-199 |
||
|
– Primary scrambling code |
Reference to clause 6.1 "Default settings (FDD)" |
RBSC-200 |
|
|
– PDSCH with SHO DCH info |
Not Present |
R99 and Rel-4 only |
RBSC-201 |
|
– PDSCH code mapping |
Not Present |
R99 and Rel-4 only |
RBSC-202 |
|
– Downlink DPCH info for each RL |
RBSC-203 |
||
|
– CHOICE mode |
FDD |
RBSC-204 |
|
|
– Primary CPICH usage for channel estimation |
Primary CPICH may be used |
RBSC-205 |
|
|
– DPCH frame offset |
Set to value Default DPCH Offset Value (as currently stored in SS) mod 38 400 |
RBSC-206 |
|
|
– Secondary CPICH info |
Not Present |
RBSC-207 |
|
|
– DL channelisation code |
RBSC-208 |
||
|
– Secondary scrambling code |
Not Present |
RBSC-209 |
|
|
– Spreading factor |
128 |
RBSC-210 |
|
|
– Code number |
96 |
RBSC-211 |
|
|
– Scrambling code change |
No change |
RBSC-212 |
|
|
– TPC combination index |
0 |
RBSC-213 |
|
|
– SSDT Cell Identity |
Not Present |
R99 and Rel-4 only |
RBSC-214 |
|
– Closed loop timing adjustment mode |
Not Present |
RBSC-215 |
|
|
– SCCPCH information for FACH |
Not Present |
R99 and Rel-4 only |
RBSC-216 |
|
MBMS PL Service Restriction Information |
Not Present |
Rel-6 |
RBSC-217 |
|
Information Element |
Condition |
Value/remark |
Version |
Index |
|
|---|---|---|---|---|---|
|
Message Type |
A1,A2 |
RBS2-001 |
|||
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
RBS2-002 |
|||
|
Integrity check info |
RBS2-003 |
||||
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
RBS2-004 |
|||
|
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
RBS2-005 |
|||
|
Integrity protection mode info |
Not Present |
RBS2-006 |
|||
|
Ciphering mode info |
Not Present |
RBS2-007 |
|||
|
Activation time |
(256+CFN-(CFN MOD 8 + 8))MOD 256 |
RBS2-008 |
|||
|
New U-RNTI |
Not Present |
RBS2-009 |
|||
|
New C-RNTI |
Not Present |
RBS2-010 |
|||
|
New DSCH-RNTI |
Not Present |
R99 and Rel-4 only |
RBS2-011 |
||
|
New H-RNTI |
Not Present |
Rel-5 |
RBS2-012 |
||
|
New Primary E-RNTI |
Not Present |
Rel-6 |
RBS2-013 |
||
|
New Secondary E-RNTI |
Not Present |
Rel-6 |
RBS2-014 |
||
|
RRC State indicator |
CELL_DCH |
RBS2-015 |
|||
|
UTRAN DRX cycle length coefficient |
Not Present |
RBS2-016 |
|||
|
CN information info |
Not Present |
RBS2-017 |
|||
|
URA identity |
Not Present |
RBS2-018 |
|||
|
CHOICE specification mode |
Complete specification |
Rel-6 |
RBS2-019 |
||
|
Signalling RB information to setup |
Not Present |
RBS2-020 |
|||
|
RAB information for setup list |
RBS2-021 |
||||
|
– RAB information for setup |
RBS2-022 |
||||
|
– RAB info |
RBS2-023 |
||||
|
– RAB identity |
0000 0001B The first/ leftmost bit of the bit string contains the most significant bit of the RAB identity. |
RBS2-024 |
|||
|
– CN domain identity |
CS domain |
RBS2-025 |
|||
|
– NAS Synchronization Indicator |
Not Present |
RBS2-026 |
|||
|
– Re-establishment timer |
UseT314 |
RBS2-027 |
|||
|
– RB information to setup list |
RBS2-028 |
||||
|
– RB information to setup |
RBS2-029 |
||||
|
– RB identity |
10 |
RBS2-030 |
|||
|
– PDCP info |
Not Present |
RBS2-031 |
|||
|
– CHOICE RLC info type |
RLC info |
RBS2-032 |
|||
|
– CHOICE Uplink RLC mode |
TM RLC |
RBS2-033 |
|||
|
– Transmission RLC discard |
Not Present |
RBS2-034 |
|||
|
– Segmentation indication |
FALSE |
RBS2-035 |
|||
|
– CHOICE Downlink RLC mode |
TM RLC |
RBS2-036 |
|||
|
– Segmentation indication |
FALSE |
RBS2-037 |
|||
|
– RB mapping info |
RBS2-038 |
||||
|
– Information for each multiplexing option |
RBS2-039 |
||||
|
– RLC logical channel mapping indicator |
Not Present |
RBS2-040 |
|||
|
– Number of uplink RLC logical channels |
1 |
RBS2-041 |
|||
|
– Uplink transport channel type |
DCH |
RBS2-042 |
|||
|
– UL Transport channel identity |
1 |
RBS2-043 |
|||
|
– Logical channel identity |
Not Present |
RBS2-044 |
|||
|
– CHOICE RLC size list |
Configured |
RBS2-045 |
|||
|
– MAC logical channel priority |
7 |
RBS2-046 |
|||
|
– Downlink RLC logical channel info |
RBS2-047 |
||||
|
– Number of downlink RLC logical channels |
1 |
RBS2-048 |
|||
|
– Downlink transport channel type |
DCH |
RBS2-049 |
|||
|
– DL DCH Transport channel identity |
6 |
RBS2-050 |
|||
|
– DL DSCH Transport channel identity |
Not Present |
RBS2-051 |
|||
|
– Logical channel identity |
Not Present |
RBS2-052 |
|||
|
RB information to reconfigure list |
Not Present |
Rel-6 |
RBS2-053 |
||
|
RB information to be affected list |
Not Present |
RBS2-054 |
|||
|
Downlink counter synchronization info |
Not Present |
RBS2-055 |
|||
|
UL Transport channel information for all transport channels |
RBS2-056 |
||||
|
– PRACH TFCS |
Not Present |
RBS2-057 |
|||
|
– CHOICE mode |
FDD |
RBS2-058 |
|||
|
– TFC subset |
Not Present |
RBS2-059 |
|||
|
– UL DCH TFCS |
RBS2-060 |
||||
|
– CHOICE TFCI signalling |
Normal |
RBS2-061 |
|||
|
– TFCI Field 1 information |
RBS2-062 |
||||
|
– CHOICE TFCS representation |
Complete reconfiguration |
RBS2-063 |
|||
|
– TFCS complete reconfigure information |
RBS2-064 |
||||
|
– CHOICE CTFC Size |
A1 |
2 bit CTFC |
RBS2-065 |
||
|
– CTFC information |
4 TFCs |
RBS2-066 |
|||
|
– 2bit CTFC |
0 |
RBS2-067 |
|||
|
– Power offset Information |
RBS2-068 |
||||
|
– CHOICE Gain Factors |
Computed Gain Factors |
RBS2-069 |
|||
|
– Reference TFC ID |
0 |
RBS2-070 |
|||
|
– CHOICE mode |
FDD |
RBS2-071 |
|||
|
– Power offset Pp-m |
Not Present |
RBS2-072 |
|||
|
– 2bit CTFC |
2 |
RBS2-073 |
|||
|
– Power offset Information |
RBS2-074 |
||||
|
– CHOICE Gain Factors |
Computed Gain Factors |
RBS2-075 |
|||
|
– Reference TFC ID |
0 |
RBS2-076 |
|||
|
– CHOICE mode |
FDD |
RBS2-077 |
|||
|
– Power offset Pp-m |
Not Present |
RBS2-078 |
|||
|
– 2bit CTFC |
1 |
RBS2-079 |
|||
|
– Power offset Information |
RBS2-080 |
||||
|
– CHOICE Gain Factors |
Computed Gain Factors |
RBS2-081 |
|||
|
– Reference TFC ID |
0 |
RBS2-082 |
|||
|
– CHOICE mode |
FDD |
RBS2-083 |
|||
|
– Power offset Pp-m |
Not Present |
RBS2-084 |
|||
|
– 2bit CTFC |
3 |
RBS2-085 |
|||
|
– Power offset Information |
RBS2-086 |
||||
|
– CHOICE Gain Factors |
Signalled Gain Factors |
RBS2-087 |
|||
|
– CHOICE mode |
FDD |
RBS2-088 |
|||
|
– Gain factor ßc |
8 |
RBS2-089 |
|||
|
– Gain factor ßd |
15 |
RBS2-090 |
|||
|
– Reference TFC ID |
0 |
RBS2-091 |
|||
|
– CHOICE mode |
FDD |
RBS2-092 |
|||
|
– Power offset Pp-m |
Not Present |
RBS2-093 |
|||
|
– CHOICE CTFC Size |
A2 |
4 bit CTFC |
RBS2-094 |
||
|
– CTFC information |
6 TFCs |
RBS2-095 |
|||
|
– 4bit CTFC |
0 |
RBS2-096 |
|||
|
– Power offset Information |
RBS2-097 |
||||
|
– CHOICE Gain Factors |
Computed Gain Factors |
RBS2-098 |
|||
|
– Reference TFC ID |
0 |
RBS2-099 |
|||
|
– CHOICE mode |
FDD |
RBS2-100 |
|||
|
– Power offset Pp-m |
Not Present |
RBS2-101 |
|||
|
– 4bit CTFC |
3 |
RBS2-102 |
|||
|
– Power offset Information |
RBS2-103 |
||||
|
– CHOICE Gain Factors |
Computed Gain Factors |
RBS2-104 |
|||
|
– Reference TFC ID |
0 |
RBS2-105 |
|||
|
– CHOICE mode |
FDD |
RBS2-106 |
|||
|
– Power offset Pp-m |
Not Present |
RBS2-107 |
|||
|
– 4bit CTFC |
1 |
RBS2-108 |
|||
|
– Power offset Information |
RBS2-109 |
||||
|
– CHOICE Gain Factors |
Computed Gain Factors |
RBS2-110 |
|||
|
– Reference TFC ID |
0 |
RBS2-111 |
|||
|
– CHOICE mode |
FDD |
RBS2-112 |
|||
|
– Power offset Pp-m |
Not Present |
RBS2-113 |
|||
|
– 4bit CTFC |
4 |
RBS2-114 |
|||
|
– Power offset Information |
RBS2-115 |
||||
|
– CHOICE Gain Factors |
Computed Gain Factors |
RBS2-116 |
|||
|
– Reference TFC ID |
0 |
RBS2-117 |
|||
|
– CHOICE mode |
FDD |
RBS2-118 |
|||
|
– Power offset Pp-m |
Not Present |
RBS2-119 |
|||
|
– 4bit CTFC |
2 |
RBS2-120 |
|||
|
– Power offset Information |
RBS2-121 |
||||
|
– CHOICE Gain Factors |
Computed Gain Factors |
RBS2-122 |
|||
|
– Reference TFC ID |
0 |
RBS2-123 |
|||
|
– CHOICE mode |
FDD |
RBS2-124 |
|||
|
– Power offset Pp-m |
Not Present |
RBS2-125 |
|||
|
– 4bit CTFC |
5 |
RBS2-126 |
|||
|
– Power offset Information |
RBS2-127 |
||||
|
– CHOICE Gain Factors |
Signalled Gain Factors |
RBS2-128 |
|||
|
– CHOICE mode |
FDD |
RBS2-129 |
|||
|
– Gain factor ßc |
8 |
RBS2-130 |
|||
|
– Gain factor ßd |
15 |
RBS2-131 |
|||
|
– Reference TFC ID |
0 |
RBS2-132 |
|||
|
– CHOICE mode |
FDD |
RBS2-133 |
|||
|
– Power offset Pp-m |
Not Present |
RBS2-134 |
|||
|
Deleted UL TrCH information list |
A1,A2 |
Not Present |
RBS2-135 |
||
|
Added or Reconfigured UL TrCH information list |
1 |
RBS2-136 |
|||
|
– Added or Reconfigured UL TrCH information |
RBS2-137 |
||||
|
– Uplink transport channel type |
DCH |
RBS2-138 |
|||
|
– UL Transport channel identity |
1 |
RBS2-139 |
|||
|
– TFS |
RBS2-140 |
||||
|
– CHOICE Transport channel type |
Dedicated transport channels |
RBS2-141 |
|||
|
– Dynamic Transport Format Information |
A1 |
RBS2-142 |
|||
|
– RLC size |
260 bits |
RBS2-143 |
|||
|
– Number of TBs and TTI List |
2 |
RBS2-144 |
|||
|
– Transmission Time Interval |
Not Present |
RBS2-145 |
|||
|
– Number of Transport blocks |
0 |
RBS2-146 |
|||
|
– Transmission Time Interval |
Not Present |
RBS2-147 |
|||
|
– Number of Transport blocks |
1 |
RBS2-148 |
|||
|
– CHOICE Logical channel List |
ALL |
RBS2-149 |
|||
|
– Dynamic Transport Format Information |
A2 |
RBS2-150 |
|||
|
– RLC size |
260 bits |
RBS2-151 |
|||
|
– Number of TBs and TTI List |
1 |
RBS2-152 |
|||
|
– Transmission Time Interval |
Not Present |
RBS2-153 |
|||
|
– Number of Transport blocks |
0 |
RBS2-154 |
|||
|
– CHOICE Logical channel List |
ALL |
RBS2-155 |
|||
|
– Dynamic Transport Format Information |
RBS2-156 |
||||
|
– RLC size |
16 bits |
RBS2-157 |
|||
|
– Number of TBs and TTI List |
1 |
RBS2-158 |
|||
|
– Transmission Time Interval |
Not Present |
RBS2-159 |
|||
|
– Number of Transport blocks |
1 |
RBS2-160 |
|||
|
– CHOICE Logical channel List |
ALL |
RBS2-161 |
|||
|
– Dynamic Transport Format Information |
RBS2-162 |
||||
|
– RLC size |
260 bits |
RBS2-163 |
|||
|
– Number of TBs and TTI List |
1 |
RBS2-164 |
|||
|
– Transmission Time Interval |
Not Present |
RBS2-165 |
|||
|
– Number of Transport blocks |
1 |
RBS2-166 |
|||
|
– CHOICE Logical channel List |
ALL |
RBS2-167 |
|||
|
– Semi-static Transport Format Information |
A1,A2 |
RBS2-168 |
|||
|
– Transmission time interval |
20 |
RBS2-169 |
|||
|
– Type of channel coding |
Convolutional |
RBS2-170 |
|||
|
– Coding Rate |
1/3 |
RBS2-171 |
|||
|
– Rate matching attribute |
256 |
RBS2-172 |
|||
|
– CRC size |
0 |
RBS2-173 |
|||
|
CHOICE mode |
Not Present |
RBS2-174 |
|||
|
DL Transport channel information common for all transport channel |
RBS2-175 |
||||
|
– SCCPCH TFCS |
Not Present |
RBS2-176 |
|||
|
– CHOICE mode |
FDD |
RBS2-177 |
|||
|
– CHOICE DL parameters |
A1 |
Same as UL |
RBS2-178 |
||
|
– CHOICE DL parameters |
A2 |
DL DCH TFCS |
RBS2-179 |
||
|
– DL DCH TFCS |
RBS2-180 |
||||
|
– CHOICE TFCI signalling |
Normal |
RBS2-181 |
|||
|
– TFCI Field 1 information |
RBS2-182 |
||||
|
– CHOICE TFCS representation |
Complete reconfiguration |
RBS2-183 |
|||
|
– TFCS complete reconfigure information |
RBS2-184 |
||||
|
– CHOICE CTFC Size |
4 bit CTFC |
RBS2-185 |
|||
|
– CTFC information |
4 TFCs |
RBS2-186 |
|||
|
– 4bit CTFC |
0 |
RBS2-187 |
|||
|
– Power offset Information |
RBS2-188 |
||||
|
– CHOICE Gain Factors |
Computed Gain Factors |
RBS2-189 |
|||
|
– Reference TFC ID |
0 |
RBS2-190 |
|||
|
– CHOICE mode |
FDD |
RBS2-191 |
|||
|
– Power offset Pp-m |
Not Present |
RBS2-192 |
|||
|
– 4bit CTFC |
2 |
RBS2-193 |
|||
|
– Power offset Information |
RBS2-194 |
||||
|
– CHOICE Gain Factors |
Computed Gain Factors |
RBS2-195 |
|||
|
– Reference TFC ID |
0 |
RBS2-196 |
|||
|
– CHOICE mode |
FDD |
RBS2-197 |
|||
|
– Power offset Pp-m |
Not Present |
RBS2-198 |
|||
|
– 4bit CTFC |
1 |
RBS2-199 |
|||
|
– Power offset Information |
RBS2-200 |
||||
|
– CHOICE Gain Factors |
Computed Gain Factors |
RBS2-201 |
|||
|
– Reference TFC ID |
0 |
RBS2-202 |
|||
|
– CHOICE mode |
FDD |
RBS2-203 |
|||
|
– Power offset Pp-m |
Not Present |
RBS2-204 |
|||
|
– 4bit CTFC |
3 |
RBS2-205 |
|||
|
– Power offset Information |
RBS2-206 |
||||
|
– CHOICE Gain Factors |
Signalled Gain Factors |
RBS2-207 |
|||
|
– CHOICE mode |
FDD |
RBS2-208 |
|||
|
– Gain factor ßc |
8 |
RBS2-209 |
|||
|
– Gain factor ßd |
15 |
RBS2-210 |
|||
|
– Reference TFC ID |
0 |
RBS2-211 |
|||
|
– CHOICE mode |
FDD |
RBS2-212 |
|||
|
– Power offset Pp-m |
Not Present |
RBS2-213 |
|||
|
Deleted DL TrCH information list |
A1,A2 |
Not Present |
RBS2-214 |
||
|
Added or Reconfigured DL TrCH information list |
1 |
RBS2-215 |
|||
|
– Added or Reconfigured DL TrCH information |
RBS2-216 |
||||
|
– Downlink transport channel type |
DCH |
RBS2-217 |
|||
|
– DL Transport channel identity |
6 |
RBS2-218 |
|||
|
– CHOICE DL parameters |
RBS2-219 |
||||
|
– CHOICE Transport channel type |
Dedicated transport channels |
RBS2-220 |
|||
|
– Dynamic Transport Format Information |
A1 |
RBS2-221 |
|||
|
– RLC size |
244 bits |
RBS2-222 |
|||
|
– Number of TBs and TTI List |
2 |
RBS2-223 |
|||
|
– Transmission Time Interval |
Not Present |
RBS2-224 |
|||
|
– Number of Transport blocks |
0 |
RBS2-225 |
|||
|
– Transmission Time Interval |
Not Present |
RBS2-226 |
|||
|
– Number of Transport blocks |
1 |
RBS2-227 |
|||
|
– CHOICE Logical channel List |
ALL |
RBS2-228 |
|||
|
– Dynamic Transport Format Information |
A2 |
RBS2-229 |
|||
|
– RLC size |
0 bits |
RBS2-230 |
|||
|
– Number of TBs and TTI List |
1 |
RBS2-231 |
|||
|
– Transmission Time Interval |
Not Present |
RBS2-232 |
|||
|
– Number of Transport blocks |
1 |
RBS2-233 |
|||
|
– CHOICE Logical channel List |
ALL |
RBS2-234 |
|||
|
– Dynamic Transport Format Information |
RBS2-235 |
||||
|
– RLC size |
244 bits |
RBS2-236 |
|||
|
– Number of TBs and TTI List |
1 |
RBS2-237 |
|||
|
– Transmission Time Interval |
Not Present |
RBS2-238 |
|||
|
– Number of Transport blocks |
1 |
RBS2-239 |
|||
|
– CHOICE Logical channel List |
ALL |
RBS2-240 |
|||
|
– Semi-static Transport Format Information |
A1,A2 |
RBS2-241 |
|||
|
– Transmission time interval |
20 |
RBS2-242 |
|||
|
– Type of channel coding |
Convolutional |
RBS2-243 |
|||
|
– Coding Rate |
1/3 |
RBS2-244 |
|||
|
– Rate matching attribute |
256 |
RBS2-245 |
|||
|
– CRC size |
16 |
RBS2-246 |
|||
|
– DCH quality target |
RBS2-247 |
||||
|
– BLER Quality value |
-20 (-2.0) |
RBS2-248 |
|||
|
Frequency info |
Not Present |
RBS2-249 |
|||
|
Maximum allowed UL TX power |
33dBm |
RBS2-250 |
|||
|
CHOICE channel requirement |
Uplink DPCH info |
Rel-5 and earlier |
RBS2-251 |
||
|
Uplink DPCH info |
Rel-6 |
RBS2-252 |
|||
|
– Uplink DPCH power control info |
RBS2-253 |
||||
|
– CHOICE mode |
FDD |
RBS2-254 |
|||
|
– DPCCH power offset |
-40 (-80dB) IE value will have no effect on the UE UL power when closed loop power control is active |
RBS2-255 |
|||
|
– PC Preamble |
1 frame |
RBS2-256 |
|||
|
– SRB delay |
7 frames |
RBS2-257 |
|||
|
– Power Control Algorithm |
Algorithm1 |
RBS2-258 |
|||
|
– TPC step size |
0 (1dB) |
RBS2-259 |
|||
|
– ACK |
Not Present |
Rel-5 |
RBS2-260 |
||
|
– NACK |
Not Present |
Rel-5 |
RBS2-261 |
||
|
– Ack-Nack repetition factor |
Not Present |
Rel-5 |
RBS2-262 |
||
|
– CHOICE mode |
FDD |
RBS2-263 |
|||
|
– Scrambling code type |
Long |
RBS2-264 |
|||
|
– Scrambling code number |
0 (0 to 16777215) |
RBS2-265 |
|||
|
– Number of DPDCH |
1 |
RBS2-266 |
|||
|
– spreading factor |
64 |
RBS2-267 |
|||
|
– TFCI existence |
TRUE |
RBS2-268 |
|||
|
– Number of FBI bit |
Not Present(0) |
RBS2-269 |
|||
|
– Puncturing Limit |
1 |
RBS2-270 |
|||
|
CHOICE Mode |
FDD |
R99 and Rel-4 only |
RBS2-271 |
||
|
– Downlink PDSCH information |
Not Present |
R99 and Rel-4 only |
RBS2-272 |
||
|
E-DCH Info |
Not Present |
Rel-6 |
RBS2-273 |
||
|
Downlink HS-PDSCH Information |
Not Present |
Rel-5 |
RBS2-274 |
||
|
Downlink information common for all radio links |
RBS2-275 |
||||
|
– Downlink DPCH info common for all RL |
RBS2-276 |
||||
|
– Timing indicator |
Maintain |
RBS2-277 |
|||
|
– CFN-targetSFN frame offset |
Not Present |
RBS2-278 |
|||
|
– Downlink DPCH power control information |
RBS2-279 |
||||
|
– CHOICE mode |
FDD |
RBS2-280 |
|||
|
– DPC mode |
0 (single) |
RBS2-281 |
|||
|
– CHOICE mode |
FDD |
RBS2-282 |
|||
|
– Power offset PPilot-DPDCH |
0 |
RBS2-283 |
|||
|
– DL rate matching restriction information |
Not Present |
RBS2-284 |
|||
|
– Spreading factor |
128 |
RBS2-285 |
|||
|
– Fixed or Flexible Position |
Fixed |
RBS2-286 |
|||
|
– TFCI existence |
TRUE |
RBS2-287 |
|||
|
– CHOICE SF |
128 |
RBS2-288 |
|||
|
– Number of bits for Pilot bits |
8 |
RBS2-289 |
|||
|
– CHOICE mode |
FDD |
RBS2-290 |
|||
|
– DPCH compressed mode info |
Not Present |
RBS2-291 |
|||
|
– TX Diversity mode |
None |
RBS2-292 |
|||
|
– SSDT information |
Not Present |
R99 and Rel-4 only |
RBS2-293 |
||
|
– Default DPCH Offset Value |
Not Present |
RBS2-294 |
|||
|
– MAC-hs reset indicator |
Not Present |
Rel-5 |
RBS2-295 |
||
|
– Post-verification period |
Not Present |
Rel-6 |
RBS2-296 |
||
|
Downlink information for per radio link list |
RBS2-297 |
||||
|
– Downlink information for each radio link |
RBS2-298 |
||||
|
– CHOICE mode |
FDD |
RBS2-299 |
|||
|
– Primary CPICH info |
RBS2-300 |
||||
|
– Primary scrambling code |
Reference to clause 6.1 "Default settings (FDD)" |
RBS2-301 |
|||
|
– PDSCH with SHO DCH info |
Not Present |
R99 and Rel-4 only |
RBS2-302 |
||
|
– PDSCH code mapping |
Not Present |
R99 and Rel-4 only |
RBS2-303 |
||
|
– Downlink DPCH info for each RL |
RBS2-304 |
||||
|
– CHOICE mode |
FDD |
RBS2-305 |
|||
|
– Primary CPICH usage for channel estimation |
Primary CPICH may be used |
RBS2-306 |
|||
|
– DPCH frame offset |
Set to value Default DPCH Offset Value (as currently stored in SS) mod 38 400 |
RBS2-307 |
|||
|
– Secondary CPICH info |
Not Present |
RBS2-308 |
|||
|
– DL channelisation code |
RBS2-309 |
||||
|
– Secondary scrambling code |
Not Present |
RBS2-310 |
|||
|
– Spreading factor |
128 |
RBS2-311 |
|||
|
– Code number |
96 |
RBS2-312 |
|||
|
– Scrambling code change |
No change |
RBS2-313 |
|||
|
– TPC combination index |
0 |
RBS2-314 |
|||
|
– SSDT Cell Identity |
Not Present |
R99 and Rel-4 only |
RBS2-315 |
||
|
– Closed loop timing adjustment mode |
Not Present |
RBS2-316 |
|||
|
– SCCPCH information for FACH |
Not Present |
R99 and Rel-4 only |
RBS2-317 |
||
|
MBMS PL Service Restriction Information |
Not Present |
Rel-6 |
RBS2-318 |
||
|
Condition |
Explanation |
|
A1 |
This IE is needed for "UE supports CS RAB for Test Loop Mode2 RMC 12.2/12.2 (TM)" |
|
A2 |
This IE is needed for "UE supports CS RAB for Test Loop Mode2 RMC 0 and 12.2 (TM)" |
Contents of RADIO BEARER SETUP message: AM or UM (HSDPA)
|
Information Element |
Value/remark |
Version |
Index |
|---|---|---|---|
|
Message Type |
RBSH-001 |
||
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
RBSH-002 |
|
|
Integrity check info |
RBSH-003 |
||
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
RBSH-004 |
|
|
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
RBSH-005 |
|
|
Integrity protection mode info |
Not Present |
RBSH-006 |
|
|
Ciphering mode info |
Not Present |
RBSH-007 |
|
|
Activation time |
Not Present |
RBSH-008 |
|
|
New U-RNTI |
Not Present |
RBSH-009 |
|
|
New C-RNTI |
Not Present |
RBSH-010 |
|
|
New H-RNTI |
‘1010 1010 1010 1010’ |
Rel-5 |
RBSH-011 |
|
New Primary E-RNTI |
Not Present |
Rel-6 |
RBSH-012 |
|
New Secondary E-RNTI |
Not Present |
Rel-6 |
RBSH-013 |
|
RRC State indicator |
CELL_DCH |
RBSH-014 |
|
|
UTRAN DRX cycle length coefficient |
Not Present |
RBSH-015 |
|
|
CN information info |
Not Present |
RBSH-016 |
|
|
URA identity |
Not Present |
RBSH-017 |
|
|
CHOICE specification mode |
Complete specification |
Rel-6 |
RBSH-018 |
|
Signalling RB information to setup |
Not Present |
RBSH-019 |
|
|
RAB information for setup list |
RBSH-020 |
||
|
– RAB information for setup |
RBSH-021 |
||
|
– RAB info |
(high-speed UM DTCH for PS domain) |
RBSH-022 |
|
|
– RAB identity |
0000 0110B The first/ leftmost bit of the bit string contains the most significant bit of the RAB identity. |
RBSH-023 |
|
|
– CN domain identity |
PS domain |
RBSH-024 |
|
|
– NAS Synchronization Indicator |
Not Present |
RBSH-025 |
|
|
– Re-establishment timer |
UseT315 |
RBSH-026 |
|
|
– RB information to setup |
RBSH-027 |
||
|
– RB identity |
25 |
RBSH-028 |
|
|
– PDCP info |
Not Present |
RBSH-029 |
|
|
– CHOICE RLC info type |
RLC info |
RBSH-030 |
|
|
– CHOICE Uplink RLC mode |
Not Present |
RBSH-031 |
|
|
– CHOICE Downlink RLC mode |
UM RLC |
RBSH-032 |
|
|
– DL UM RLC LI size |
Selected with DL UM RLC data size |
Rel-5 |
RBSH-033 |
|
– One sided RLC re-establishment |
FALSE |
Rel-5 |
RBSH-034 |
|
– RB mapping info |
RBSH-035 |
||
|
– Information for each multiplexing option |
1 RBMuxOptions |
RBSH-036 |
|
|
– RLC logical channel mapping indicator |
Not Present |
RBSH-037 |
|
|
– Downlink RLC logical channel info |
RBSH-038 |
||
|
– Number of downlink RLC logical channels |
1 |
RBSH-039 |
|
|
– Downlink transport channel type |
HS-DSCH |
RBSH-040 |
|
|
– DL DCH Transport channel identity |
Not Present |
RBSH-041 |
|
|
– DL DSCH Transport channel identity |
Not Present |
RBSH-042 |
|
|
– CHOICE DL MAC header type |
MAC-hs |
Rel-7 |
RBSH-043 |
|
– DL HS-DSCH MAC-d flow identity |
0 |
RBSH-044 |
|
|
– Logical channel identity |
Not Present |
RBSH-045 |
|
|
RB information to reconfigure list |
Not Present |
Rel-6 |
RBSH-046 |
|
RB information to be affected list |
Not Present |
RBSH-047 |
|
|
Downlink counter synchronization info |
Not Present |
RBSH-048 |
|
|
PDCP ROHC target mode |
Not Present |
Rel-5 |
RBSH-049 |
|
UL Transport channel information for all transport channels |
RBSH-050 |
||
|
– PRACH TFCS |
Not Present |
RBSH-051 |
|
|
– CHOICE mode |
FDD |
RBSH-052 |
|
|
– TFC subset |
Not Present |
RBSH-053 |
|
|
– UL DCH TFCS |
RBSH-054 |
||
|
– CHOICE TFCI signalling |
Normal |
RBSH-055 |
|
|
– TFCI Field 1 information |
RBSH-056 |
||
|
– CHOICE TFCS representation |
Complete reconfiguration |
RBSH-057 |
|
|
– TFCS complete reconfigure information |
RBSH-058 |
||
|
– CHOICE CTFC Size |
2 bit CTFC |
RBSH-059 |
|
|
– CTFC information |
4 TFCs |
RBSH-060 |
|
|
– CTFC |
Reference to clause TS 34.121 clause C.2.1 Parameter Set |
RBSH-061 |
|
|
– Power offset information |
RBSH-062 |
||
|
– CHOICE Gain Factors |
Computed Gain Factors(The last TFC is set to Signalled Gain Factors) |
RBSH-063 |
|
|
– Gain factor βc |
8 (Not Present if the CHOICE Gain Factors is set to Computed Gain Factors) |
RBSH-064 |
|
|
– Gain factor βd |
15 (Not Present if the CHOICE Gain Factors is set to Computed Gain Factors) |
RBSH-065 |
|
|
– Reference TFC ID |
0 |
RBSH-066 |
|
|
– CHOICE mode |
FDD |
RBSH-067 |
|
|
– Power offset P p-m |
Not Present |
RBSH-068 |
|
|
Deleted UL TrCH information list |
Not Present |
RBSH-069 |
|
|
Added or Reconfigured TrCH information list |
Not Present |
RBSH-070 |
|
|
CHOICE mode |
Not Present |
RBSH-071 |
|
|
DL Transport channel information common for all transport channel |
RBSH-072 |
||
|
– SCCPCH TFCS |
Not Present |
RBSH-073 |
|
|
– CHOICE mode |
FDD |
RBSH-074 |
|
|
– CHOICE DL parameters |
Explicit |
RBSH-075 |
|
|
– DL DCH TFCS |
RBSH-076 |
||
|
– CHOICE TFCI Signalling |
Normal |
RBSH-077 |
|
|
– TFCI Field 1 Information |
RBSH-078 |
||
|
– CHOICE TFCS representation |
Complete reconfiguration |
RBSH-079 |
|
|
– TFCS complete reconfigure |
RBSH-080 |
||
|
– CHOICE CTFC Size |
2 bit CTFC |
RBSH-081 |
|
|
– CTFC information |
4 TFCs |
RBSH-082 |
|
|
– CTFC |
Reference to clause TS 34.121 clause C.3.1 Parameter Set |
RBSH-083 |
|
|
– Power offset information |
Not Present |
RBSH-084 |
|
|
Deleted DL TrCH information |
Not Present |
RBSH-085 |
|
|
Added or Reconfigured DL TrCH information list |
1 TrCHs added |
RBSH-086 |
|
|
– Added or Reconfigured DL TrCH information |
(HS-DSCH for DTCH) |
RBSH-087 |
|
|
– Downlink transport channel type |
HS-DSCH |
Rel-5 |
RBSH-088 |
|
– DL Transport channel identity |
Not Present |
RBSH-089 |
|
|
– CHOICE DL parameters |
HS-DSCH |
RBSH-090 |
|
|
– HARQ Info |
Rel-5 |
RBSH-091 |
|
|
– Number of Processes |
Reference to TS34.121 [2] Annex C Fixed Reference Channels |
RBSH-092 |
|
|
– CHOICE Memory Partitioning |
Explicit |
RBSH-093 |
|
|
– Memory size |
Reference to TS34.121 [2] Annex C Fixed Reference Channels parameter “Number of HARQ Processes”. |
RBSH-094 |
|
|
– Process Memory Size |
Reference to TS34.121 [2] Annex C Fixed Reference Channels parameter “Number of SML’s per HARQ Proc.”. |
RBSH-095 |
|
|
– Additional memory sizes for MIMO |
Not Present |
Rel-7 |
RBSH-096 |
|
– CHOICE DL MAC header type |
MAC-hs |
Rel-7 |
RBSH-097 |
|
– Added or reconfigured MAC-d flow |
RBSH-098 |
||
|
– MAC-hs queue to add or reconfigure list |
(one queue) |
Rel-5 |
RBSH-099 |
|
– MAC-hs queue Id |
0 |
RBSH-100 |
|
|
– MAC-d Flow Identity |
0 |
RBSH-101 |
|
|
– T1 |
50 |
RBSH-102 |
|
|
– MAC-hs window size |
16 |
RBSH-103 |
|
|
– MAC-d PDU size Info |
RBSH-104 |
||
|
– MAC-d PDU size |
Reference to TS34.121 [2] Annex C Fixed Reference Channels |
RBSH-105 |
|
|
– MAC-d PDU size index |
0 |
RBSH-106 |
|
|
– MAC-hs queue to delete list |
Not present |
RBSH-107 |
|
|
– DCH quality target |
Not present |
RBSH-108 |
|
|
Frequency info |
Not Present |
RBSH-109 |
|
|
Multi-frequency Info |
Not present |
Rel-7 |
RBSH-110 |
|
DTX-DRX timing information |
Not present |
Rel-7 |
RBSH-111 |
|
DRX Information |
Not present |
Rel-7 |
RBSH-112 |
|
HS-SCCH less Information |
Not present |
Rel-7 |
RBSH-113 |
|
MIMO parameters |
Not present |
Rel-7 |
RBSH-114 |
|
Maximum allowed UL TX power |
33dBm |
RBSH-115 |
|
|
CHOICE channel requirement |
Uplink DPCH info |
Rel-5 and earlier |
RBSH-116 |
|
Uplink DPCH info |
Rel-6 |
RBSH-117 |
|
|
– Uplink DPCH power control info |
RBSH-118 |
||
|
– CHOICE mode |
FDD |
RBSH-119 |
|
|
– DPCCH power offset |
-40 (-80dB) IE value will have no effect on the UE UL power when closed loop power control is active |
RBSH-120 |
|
|
– PC Preamble |
1 frame |
RBSH-121 |
|
|
– SRB delay |
7 frames |
RBSH-122 |
|
|
– Power Control Algorithm |
Algorithm1 |
RBSH-123 |
|
|
– TPC step size |
0 (1dB) |
RBSH-124 |
|
|
– ACK |
3 |
Rel-5 |
RBSH-125 |
|
– NACK |
3 |
Rel-5 |
RBSH-126 |
|
– Ack-Nack repetition factor |
1 |
Rel-5 |
RBSH-127 |
|
– CHOICE mode |
FDD |
RBSH-128 |
|
|
– Scrambling code type |
Long |
RBSH-129 |
|
|
– Scrambling code number |
0 (0 to 16777215) |
RBSH-130 |
|
|
– Number of DPDCH |
Not Present (1) |
RBSH-131 |
|
|
– spreading factor |
64 |
RBSH-132 |
|
|
– TFCI existence |
TRUE |
RBSH-133 |
|
|
– Number of FBI bit |
Not Present(0) |
RBSH-134 |
|
|
– Puncturing Limit |
1 |
RBSH-135 |
|
|
CHOICE Mode |
FDD |
R99 and Rel-4 only |
RBSH-136 |
|
– Downlink PDSCH information |
Not Present |
R99 and Rel-4 only |
RBSH-137 |
|
E-DCH Info |
Not Present |
Rel-6 |
RBSH-138 |
|
Downlink HS-PDSCH Information |
RBSH-139 |
||
|
– HS-SCCH Info |
RBSH-140 |
||
|
– CHOICE mode |
FDD |
RBSH-141 |
|
|
– DL Scrambling Code |
RBSH-142 |
||
|
– HS-SCCH Channelisation Code Information |
RBSH-143 |
||
|
– HS-SCCH Channelisation Code |
2 |
RBSH-144 |
|
|
– HS-SCCH Channelisation Code |
3 |
RBSH-145 |
|
|
– HS-SCCH Channelisation Code |
6 |
RBSH-146 |
|
|
– HS-SCCH Channelisation Code |
7 |
RBSH-147 |
|
|
– Measurement Feedback Info |
RBSH-148 |
||
|
– CHOICE mode |
FDD |
RBSH-149 |
|
|
– POhsdsch |
6 dB |
Rel-5 |
RBSH-150 |
|
– CQI Feedback cycle, k |
2 ms |
Rel-5 |
RBSH-151 |
|
– CQI repetition factor |
1 |
Rel-5 |
RBSH-152 |
|
– CQI |
5 (corresponds to 0dB in relative power offset) |
Rel-5 |
RBSH-153 |
|
– CHOICE mode |
FDD |
RBSH-154 |
|
|
– Downlink 64QAM configured |
Not Present |
Rel-7 |
RBSH-155 |
|
Downlink information common for all radio links |
Not Present |
RBSH-156 |
|
|
Downlink information per radio link list |
RBSH-157 |
||
|
– Downlink information for each radio link |
RBSH-158 |
||
|
– CHOICE mode |
FDD |
RBSH-159 |
|
|
– Primary CPICH info |
RBSH-160 |
||
|
– Primary scrambling code |
Reference to clause 6.1 "Default settings (FDD)" |
RBSH-161 |
|
|
– PDSCH with SHO DCH info |
Not Present |
R99 and Rel-4 only |
RBSH-162 |
|
– PDSCH code mapping |
Not Present |
R99 and Rel-4 only |
RBSH-163 |
|
– Serving HS-DSCH radio link indicator |
TRUE |
Rel-5 |
RBSH-164 |
|
– Downlink DPCH info for each RL |
RBSH-165 |
||
|
– CHOICE mode |
FDD |
RBSH-166 |
|
|
– Primary CPICH usage for channel estimation |
Primary CPICH may be used |
RBSH-167 |
|
|
– DPCH frame offset |
Set to value Default DPCH Offset Value (as currently stored in SS) mod 38 400 |
RBSH-168 |
|
|
– Secondary CPICH info |
Not Present |
RBSH-169 |
|
|
– DL channelisation code |
RBSH-170 |
||
|
– Secondary scrambling code |
Not present |
RBSH-171 |
|
|
– Spreading factor |
128 |
RBSH-172 |
|
|
– Code number |
96 |
RBSH-173 |
|
|
– Scrambling code change |
No change |
RBSH-174 |
|
|
– TPC combination index |
0 |
RBSH-175 |
|
|
– SSDT Cell Identity |
Not Present |
R99 and Rel-4 only |
RBSH-176 |
|
– Closed loop timing adjustment mode |
Not Present |
RBSH-177 |
|
|
– SCCPCH information for FACH |
Not Present |
R99 and Rel-4 only |
RBSH-178 |
|
MBMS PL Service Restriction Information |
Not Present |
Rel-6 |
RBSH-179 |
Contents of RADIO BEARER SETUP message: BTFD RMC for Test Loop Mode 2
|
Information Element |
Value/remark |
Version |
Index |
|---|---|---|---|
|
Message Type |
RBSB-001 |
||
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
RBSB-002 |
|
|
Integrity check info |
RBSB-003 |
||
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
RBSB-004 |
|
|
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
RBSB-005 |
|
|
Integrity protection mode info |
Not Present |
RBSB-006 |
|
|
Ciphering mode info |
Not Present. For correct operation of test loop mode 2 this IE shall be omitted. |
RBSB-007 |
|
|
Activation time |
(256+CFN-(CFN MOD 8 + 8))MOD 256 |
RBSB-008 |
|
|
New U-RNTI |
Not Present |
RBSB-009 |
|
|
New C-RNTI |
Not Present |
RBSB-010 |
|
|
New DSCH-RNTI |
Not Present |
R99 and Rel-4 only |
RBSB-011 |
|
New H-RNTI |
Not Present |
Rel-5 |
RBSB-012 |
|
New Primary E-RNTI |
Not Present |
Rel-6 |
RBSB-013 |
|
New Secondary E-RNTI |
Not Present |
Rel-6 |
RBSB-014 |
|
RRC State indicator |
CELL_DCH |
RBSB-015 |
|
|
UTRAN DRX cycle length coefficient |
Not Present |
RBSB-016 |
|
|
CN information info |
Not Present |
RBSB-017 |
|
|
URA identity |
Not Present |
RBSB-018 |
|
|
CHOICE specification mode |
Complete specification |
Rel-5 |
RBSB-019 |
|
– RAB information for setup |
RBSB-020 |
||
|
– RAB info |
RBSB-021 |
||
|
– RAB identity |
0000 0001B The first/ leftmost bit of the bit string contains the most significant bit of the RAB identity. |
RBSB-022 |
|
|
– CN domain identity |
CS domain |
RBSB-023 |
|
|
– NAS Synchronization Indicator |
Not Present |
RBSB-024 |
|
|
– Re-establishment timer |
UseT314 |
RBSB-025 |
|
|
– RB information to setup |
RBSB-026 |
||
|
– RB identity |
10 |
RBSB-027 |
|
|
– PDCP info |
Not Present |
RBSB-028 |
|
|
– CHOICE RLC info type |
RLC info |
RBSB-029 |
|
|
– CHOICE Uplink RLC mode |
TM RLC |
RBSB-030 |
|
|
– Transmission RLC discard |
Not Present |
RBSB-031 |
|
|
– Segmentation indication |
FALSE |
RBSB-032 |
|
|
– CHOICE Downlink RLC mode |
TM RLC |
RBSB-033 |
|
|
– Segmentation indication |
FALSE |
RBSB-034 |
|
|
– RB mapping info |
RBSB-035 |
||
|
– Information for each multiplexing option |
RBSB-036 |
||
|
– RLC logical channel mapping indicator |
Not Present |
RBSB-037 |
|
|
– Number of uplink RLC logical channels |
1 |
RBSB-038 |
|
|
– Uplink transport channel type |
DCH |
RBSB-039 |
|
|
– UL Transport channel identity |
1 |
RBSB-040 |
|
|
– Logical channel identity |
Not Present |
RBSB-041 |
|
|
– CHOICE RLC size list |
Configured |
RBSB-042 |
|
|
– MAC logical channel priority |
7 |
RBSB-043 |
|
|
– Downlink RLC logical channel info |
RBSB-044 |
||
|
– Number of downlink RLC logical channels |
1 |
RBSB-045 |
|
|
– Downlink transport channel type |
DCH |
RBSB-046 |
|
|
– DL DCH Transport channel identity |
6 |
RBSB-047 |
|
|
– DL DSCH Transport channel identity |
Not Present |
RBSB-048 |
|
|
– Logical channel identity |
Not Present |
RBSB-049 |
|
|
RB information to reconfigure list |
Not Present |
Rel-6 |
RBSB-050 |
|
RB information to be affected |
Not Present |
RBSB-051 |
|
|
Downlink counter synchronization info |
Not Present |
RBSB-052 |
|
|
RMC for BTFD |
RBSB-053 |
||
|
UL Transport channel information for all transport channels |
RBSB-054 |
||
|
– PRACH TFCS |
Not Present |
RBSB-055 |
|
|
– CHOICE mode |
FDD |
RBSB-056 |
|
|
– TFC subset |
Not Present |
RBSB-057 |
|
|
– UL DCH TFCS |
RBSB-058 |
||
|
– CHOICE TFCI signalling |
Normal |
RBSB-059 |
|
|
– TFCI Field 1 information |
RBSB-060 |
||
|
– CHOICE TFCS representation |
Complete reconfiguration |
RBSB-061 |
|
|
– TFCS complete reconfigure information |
RBSB-062 |
||
|
– CHOICE CTFC Size |
ctfc6Bit |
RBSB-063 |
|
|
– ctfc6Bit |
22 |
RBSB-064 |
|
|
– ctfc6 |
0 |
RBSB-065 |
|
|
-powerOffsetInformation(OP) |
RBSB-066 |
||
|
-gainFactorInformation |
ComputedGainFactors |
RBSB-067 |
|
|
– Reference TFC ID |
0 |
RBSB-068 |
|
|
– ctfc6 |
11 |
RBSB-069 |
|
|
-powerOffsetInformation(OP) |
RBSB-070 |
||
|
-gainFactorInformation |
ComputedGainFactors |
RBSB-071 |
|
|
– Reference TFC ID |
0 |
RBSB-072 |
|
|
– ctfc6 |
1 |
RBSB-073 |
|
|
-powerOffsetInformation(OP) |
RBSB-074 |
||
|
-gainFactorInformation |
ComputedGainFactors |
RBSB-075 |
|
|
– Reference TFC ID |
0 |
RBSB-076 |
|
|
– ctfc6 |
12 |
RBSB-077 |
|
|
-powerOffsetInformation(OP) |
RBSB-078 |
||
|
-gainFactorInformation |
SignalledGainFactors |
RBSB-079 |
|
|
-modeSpecificInfo |
Fdd |
RBSB-080 |
|
|
-fdd |
RBSB-081 |
||
|
– Gain factor ßc |
8 |
RBSB-082 |
|
|
– Gain factor ßd |
15 |
RBSB-083 |
|
|
– Reference TFC ID |
0 |
RBSB-084 |
|
|
– ctfc6 |
2 |
RBSB-085 |
|
|
-powerOffsetInformation(OP) |
RBSB-086 |
||
|
-gainFactorInformation |
ComputedGainFactors |
RBSB-087 |
|
|
– Reference TFC ID |
0 |
RBSB-088 |
|
|
– ctfc6 |
13 |
RBSB-089 |
|
|
-powerOffsetInformation(OP) |
RBSB-090 |
||
|
-gainFactorInformation |
ComputedGainFactors |
RBSB-091 |
|
|
– Reference TFC ID |
0 |
RBSB-092 |
|
|
– ctfc6 |
3 |
RBSB-093 |
|
|
-powerOffsetInformation(OP) |
RBSB-094 |
||
|
-gainFactorInformation |
ComputedGainFactors |
RBSB-095 |
|
|
– Reference TFC ID |
0 |
RBSB-096 |
|
|
– ctfc6 |
14 |
RBSB-097 |
|
|
-powerOffsetInformation(OP) |
RBSB-098 |
||
|
-gainFactorInformation |
ComputedGainFactors |
RBSB-099 |
|
|
– Reference TFC ID |
0 |
RBSB-100 |
|
|
– ctfc6 |
4 |
RBSB-101 |
|
|
-powerOffsetInformation(OP) |
RBSB-102 |
||
|
-gainFactorInformation |
ComputedGainFactors |
RBSB-103 |
|
|
– Reference TFC ID |
0 |
RBSB-104 |
|
|
– ctfc6 |
15 |
RBSB-105 |
|
|
-powerOffsetInformation(OP) |
RBSB-106 |
||
|
-gainFactorInformation |
ComputedGainFactors |
RBSB-107 |
|
|
– Reference TFC ID |
0 |
RBSB-108 |
|
|
– ctfc6 |
5 |
RBSB-109 |
|
|
-powerOffsetInformation(OP) |
RBSB-110 |
||
|
-gainFactorInformation |
ComputedGainFactors |
RBSB-111 |
|
|
– Reference TFC ID |
0 |
RBSB-112 |
|
|
– ctfc6 |
16 |
RBSB-113 |
|
|
-powerOffsetInformation(OP) |
RBSB-114 |
||
|
-gainFactorInformation |
ComputedGainFactors |
RBSB-115 |
|
|
– Reference TFC ID |
0 |
RBSB-116 |
|
|
– ctfc6 |
6 |
RBSB-117 |
|
|
-powerOffsetInformation(OP) |
RBSB-118 |
||
|
-gainFactorInformation |
ComputedGainFactors |
RBSB-119 |
|
|
– Reference TFC ID |
1 |
RBSB-120 |
|
|
– ctfc6 |
17 |
RBSB-121 |
|
|
-powerOffsetInformation(OP) |
RBSB-122 |
||
|
-gainFactorInformation |
SignalledGainFactors |
RBSB-123 |
|
|
-modeSpecificInfo |
Fdd |
RBSB-124 |
|
|
-fdd |
RBSB-125 |
||
|
– Gain factor ßc |
11 |
RBSB-126 |
|
|
– Gain factor ßd |
15 |
RBSB-127 |
|
|
– Reference TFC ID |
1 |
RBSB-128 |
|
|
– ctfc6 |
7 |
RBSB-129 |
|
|
-powerOffsetInformation(OP) |
RBSB-130 |
||
|
-gainFactorInformation |
ComputedGainFactors |
RBSB-131 |
|
|
– Reference TFC ID |
1 |
RBSB-132 |
|
|
– ctfc6 |
18 |
RBSB-133 |
|
|
-powerOffsetInformation(OP) |
RBSB-134 |
||
|
-gainFactorInformation |
ComputedGainFactors |
RBSB-135 |
|
|
– Reference TFC ID |
1 |
RBSB-136 |
|
|
– ctfc6 |
8 |
RBSB-137 |
|
|
-powerOffsetInformation(OP) |
RBSB-138 |
||
|
-gainFactorInformation |
ComputedGainFactors |
RBSB-139 |
|
|
– Reference TFC ID |
1 |
RBSB-140 |
|
|
– ctfc6 |
19 |
RBSB-141 |
|
|
-powerOffsetInformation(OP) |
RBSB-142 |
||
|
-gainFactorInformation |
ComputedGainFactors |
RBSB-143 |
|
|
– Reference TFC ID |
1 |
RBSB-144 |
|
|
– ctfc6 |
9 |
RBSB-145 |
|
|
-powerOffsetInformation(OP) |
RBSB-146 |
||
|
-gainFactorInformation |
ComputedGainFactors |
RBSB-147 |
|
|
– Reference TFC ID |
1 |
RBSB-148 |
|
|
– ctfc6 |
20 |
RBSB-149 |
|
|
-powerOffsetInformation(OP) |
RBSB-150 |
||
|
-gainFactorInformation |
ComputedGainFactors |
RBSB-151 |
|
|
– Reference TFC ID |
1 |
RBSB-152 |
|
|
– ctfc6 |
10 |
RBSB-153 |
|
|
-powerOffsetInformation(OP) |
RBSB-154 |
||
|
-gainFactorInformation |
ComputedGainFactors |
RBSB-155 |
|
|
– Reference TFC ID |
1 |
RBSB-156 |
|
|
– ctfc6 |
21 |
RBSB-157 |
|
|
-powerOffsetInformation(OP) |
RBSB-158 |
||
|
-gainFactorInformation |
ComputedGainFactors |
RBSB-159 |
|
|
– Reference TFC ID |
1 |
RBSB-160 |
|
|
Added or Reconfigured UL TrCH information list |
1 |
RBSB-161 |
|
|
– Added or Reconfigured UL TrCH information |
RBSB-162 |
||
|
– Uplink transport channel type |
DCH |
RBSB-163 |
|
|
– UL Transport channel identity |
1 |
RBSB-164 |
|
|
– TFS |
RBSB-165 |
||
|
– CHOICE Transport channel type |
Dedicated transport channels |
RBSB-166 |
|
|
-DedicatedDynamicTF-Info |
RBSB-167 |
||
|
RLC size |
256 |
RBSB-168 |
|
|
-numberOfTbSizeList |
RBSB-169 |
||
|
-NumberOfTransportBlocks |
Zero |
RBSB-170 |
|
|
-NumberOfTransportBlocks |
One |
RBSB-171 |
|
|
– Choice Logical channel List |
ALL |
RBSB-172 |
|
|
RLC size |
216 |
RBSB-173 |
|
|
-numberOfTbSizeList |
RBSB-174 |
||
|
-NumberOfTransportBlocks |
One |
RBSB-175 |
|
|
– Choice Logical channel List |
ALL |
RBSB-176 |
|
|
RLC size |
171 |
RBSB-177 |
|
|
-numberOfTbSizeList |
RBSB-178 |
||
|
-NumberOfTransportBlocks |
One |
RBSB-179 |
|
|
– Choice Logical channel List |
ALL |
RBSB-180 |
|
|
RLC size |
160 |
RBSB-181 |
|
|
-numberOfTbSizeList |
RBSB-182 |
||
|
-NumberOfTransportBlocks |
One |
RBSB-183 |
|
|
– Choice Logical channel List |
ALL |
RBSB-184 |
|
|
RLC size |
146 |
RBSB-185 |
|
|
-numberOfTbSizeList |
RBSB-186 |
||
|
-NumberOfTransportBlocks |
One |
RBSB-187 |
|
|
– Choice Logical channel List |
ALL |
RBSB-188 |
|
|
RLC size |
130 |
RBSB-189 |
|
|
-numberOfTbSizeList |
RBSB-190 |
||
|
-NumberOfTransportBlocks |
One |
RBSB-191 |
|
|
– Choice Logical channel List |
ALL |
RBSB-192 |
|
|
RLC size |
115 |
RBSB-193 |
|
|
-numberOfTbSizeList |
RBSB-194 |
||
|
-NumberOfTransportBlocks |
One |
RBSB-195 |
|
|
– Choice Logical channel List |
ALL |
RBSB-196 |
|
|
RLC size |
107 |
RBSB-197 |
|
|
-numberOfTbSizeList |
RBSB-198 |
||
|
-NumberOfTransportBlocks |
One |
RBSB-199 |
|
|
– Choice Logical channel List |
ALL |
RBSB-200 |
|
|
RLC size |
51 |
RBSB-201 |
|
|
-numberOfTbSizeList |
RBSB-202 |
||
|
-NumberOfTransportBlocks |
One |
RBSB-203 |
|
|
– Choice Logical channel List |
ALL |
RBSB-204 |
|
|
RLC size |
12 |
RBSB-205 |
|
|
-numberOfTbSizeList |
RBSB-206 |
||
|
-NumberOfTransportBlocks |
One |
RBSB-207 |
|
|
– Choice Logical channel List |
ALL |
RBSB-208 |
|
|
-Semistatic Transport Format Information |
RBSB-209 |
||
|
-Transmission Time interval |
20 ms |
RBSB-210 |
|
|
-channelCodingType |
Convolutional |
RBSB-211 |
|
|
-convolutional |
1/3 |
RBSB-212 |
|
|
– Rate matching attribute |
256 |
RBSB-213 |
|
|
– CRC size |
0 |
RBSB-214 |
|
|
DL Transport channel information common for all transport channel |
RBSB-215 |
||
|
– SCCPCH TFCS |
Not Present |
RBSB-216 |
|
|
– CHOICE mode |
FDD |
RBSB-217 |
|
|
– CHOICE DL parameters |
Explicit |
RBSB-218 |
|
|
– DL DCH TFCS |
RBSB-219 |
||
|
– CHOICE TFCI signalling |
Normal |
RBSB-220 |
|
|
– TFCI Field 1 information |
RBSB-221 |
||
|
– CHOICE TFCS representation |
Complete reconfiguration |
RBSB-222 |
|
|
– TFCS complete reconfigure information |
RBSB-223 |
||
|
– CHOICE CTFC Size |
Ctfc6Bit |
RBSB-224 |
|
|
– ctfc6Bit |
18 |
RBSB-225 |
|
|
– ctfc6 |
9 |
RBSB-226 |
|
|
– ctfc6 |
0 |
RBSB-227 |
|
|
– ctfc6 |
10 |
RBSB-228 |
|
|
– ctfc6 |
1 |
RBSB-229 |
|
|
– ctfc6 |
11 |
RBSB-230 |
|
|
– ctfc6 |
2 |
RBSB-231 |
|
|
– ctfc6 |
12 |
RBSB-232 |
|
|
– ctfc6 |
3 |
RBSB-233 |
|
|
– ctfc6 |
13 |
RBSB-234 |
|
|
– ctfc6 |
4 |
RBSB-235 |
|
|
– ctfc6 |
14 |
RBSB-236 |
|
|
– ctfc6 |
5 |
RBSB-237 |
|
|
– ctfc6 |
15 |
RBSB-238 |
|
|
– ctfc6 |
6 |
RBSB-239 |
|
|
– ctfc6 |
16 |
RBSB-240 |
|
|
– ctfc6 |
7 |
RBSB-241 |
|
|
– ctfc6 |
17 |
RBSB-242 |
|
|
– ctfc6 |
8 |
RBSB-243 |
|
|
Deleted DL TrCH information |
Not Present |
RBSB-244 |
|
|
Added or Reconfigured DL TrCH information list |
1 |
RBSB-245 |
|
|
– Added or Reconfigured DL TrCH information |
RBSB-246 |
||
|
– Downlink transport channel type |
DCH |
RBSB-247 |
|
|
– DL Transport channel identity |
6 |
RBSB-248 |
|
|
– CHOICE DL parameters |
Explicit |
RBSB-249 |
|
|
– TFS |
RBSB-250 |
||
|
– CHOICE Transport channel type |
Dedicated transport channels |
RBSB-251 |
|
|
-DedicatedDynamicTF-Info |
RBSB-252 |
||
|
RLC size |
244 |
RBSB-253 |
|
|
-numberOfTbSizeList |
RBSB-254 |
||
|
-NumberOfTransportBlocks |
One |
RBSB-255 |
|
|
– Choice Logical channel List |
ALL |
RBSB-256 |
|
|
RLC size |
204 |
RBSB-257 |
|
|
-numberOfTbSizeList |
RBSB-258 |
||
|
-NumberOfTransportBlocks |
One |
RBSB-259 |
|
|
– Choice Logical channel List |
ALL |
RBSB-260 |
|
|
RLC size |
159 |
RBSB-261 |
|
|
-numberOfTbSizeList |
RBSB-262 |
||
|
-NumberOfTransportBlocks |
One |
RBSB-263 |
|
|
– Choice Logical channel List |
ALL |
RBSB-264 |
|
|
RLC size |
148 |
RBSB-265 |
|
|
-numberOfTbSizeList |
RBSB-266 |
||
|
-NumberOfTransportBlocks |
One |
RBSB-267 |
|
|
– Choice Logical channel List |
ALL |
RBSB-268 |
|
|
RLC size |
134 |
RBSB-269 |
|
|
-numberOfTbSizeList |
RBSB-270 |
||
|
-NumberOfTransportBlocks |
One |
RBSB-271 |
|
|
– Choice Logical channel List |
ALL |
RBSB-272 |
|
|
RLC size |
118 |
RBSB-273 |
|
|
-numberOfTbSizeList |
RBSB-274 |
||
|
-NumberOfTransportBlocks |
One |
RBSB-275 |
|
|
– Choice Logical channel List |
ALL |
RBSB-276 |
|
|
RLC size |
103 |
RBSB-277 |
|
|
-numberOfTbSizeList |
RBSB-278 |
||
|
-NumberOfTransportBlocks |
One |
RBSB-279 |
|
|
– Choice Logical channel List |
ALL |
RBSB-280 |
|
|
RLC size |
95 |
RBSB-281 |
|
|
-numberOfTbSizeList |
RBSB-282 |
||
|
-NumberOfTransportBlocks |
One |
RBSB-283 |
|
|
– Choice Logical channel List |
ALL |
RBSB-284 |
|
|
RLC size |
39 |
RBSB-285 |
|
|
-numberOfTbSizeList |
RBSB-286 |
||
|
-NumberOfTransportBlocks |
One |
RBSB-287 |
|
|
– Choice Logical channel List |
ALL |
RBSB-288 |
|
|
-Semistatic Transport Format Information |
RBSB-289 |
||
|
-Transmission Time interval |
20 ms |
RBSB-290 |
|
|
-channelCodingType |
Convolutional |
RBSB-291 |
|
|
-convolutional |
1/3 |
RBSB-292 |
|
|
– Rate matching attribute |
256 |
RBSB-293 |
|
|
– CRC size |
12 |
RBSB-294 |
|
|
– DCH quality target |
RBSB-295 |
||
|
– BLER Quality value |
-20 (-2.0) |
RBSB-296 |
|
|
– Transparent mode signalling info |
Not Present |
RBSB-297 |
|
|
Frequency info |
Not Present |
RBSB-298 |
|
|
Multi-frequency Info |
Not present |
Rel-7 |
RBSB-299 |
|
DTX-DRX timing information |
Not present |
Rel-7 |
RBSB-300 |
|
DRX Information |
Not present |
Rel-7 |
RBSB-301 |
|
HS-SCCH less Information |
Not present |
Rel-7 |
RBSB-302 |
|
MIMO parameters |
Not present |
Rel-7 |
RBSB-303 |
|
Maximum allowed UL TX power |
33 dBm |
RBSB-304 |
|
|
CHOICE channel requirement |
Uplink DPCH info |
Rel-5 and earlier |
RBSB-305 |
|
Uplink DPCH info |
Rel-6 |
RBSB-306 |
|
|
– Uplink DPCH power control info |
RBSB-307 |
||
|
– DPCCH power offset |
-40 (-80dB) IE value will have no effect on the UE UL power when closed loop power control is active |
RBSB-308 |
|
|
– PC Preamble |
1 frame |
RBSB-309 |
|
|
– SRB delay |
7 frames |
RBSB-310 |
|
|
– Power Control Algorithm |
Algorithm1 |
RBSB-311 |
|
|
– TPC step size |
0 (1dB) |
RBSB-312 |
|
|
– ACK |
Not Present |
Rel-5 |
RBSB-313 |
|
– NACK |
Not Present |
Rel-5 |
RBSB-314 |
|
– Ack-Nack repetition factor |
Not Present |
Rel-5 |
RBSB-315 |
|
– Scrambling code type |
Long |
RBSB-316 |
|
|
– Scrambling code number |
0 |
RBSB-317 |
|
|
– Number of DPDCH |
1 |
RBSB-318 |
|
|
– spreading factor |
64 |
RBSB-319 |
|
|
– TFCI existence |
TRUE |
RBSB-320 |
|
|
– Number of FBI bit |
Not Present(0) |
RBSB-321 |
|
|
– Puncturing Limit |
1 |
RBSB-322 |
|
|
CHOICE Mode |
FDD |
R99 and Rel-4 only |
RBSB-323 |
|
– Downlink PDSCH information |
Not Present(0) |
R99 and Rel-4 only |
RBSB-324 |
|
E-DCH Info |
Not Present |
Rel-6 |
RBSB-325 |
|
Downlink HS-PDSCH Information |
Not Present |
Rel-5 |
RBSB-326 |
|
Downlink information common for all radio links |
RBSB-327 |
||
|
– Downlink DPCH info common for all RL |
FDD |
RBSB-328 |
|
|
– Timing indicator |
Maintain |
RBSB-329 |
|
|
– CFN-targetSFN frame offset |
Not Present |
RBSB-330 |
|
|
– Downlink DPCH power control information |
RBSB-331 |
||
|
– DPC mode |
0 (single) |
RBSB-332 |
|
|
– CHOICE mode |
FDD |
RBSB-333 |
|
|
– Power offset PPilot-DPDCH |
0 |
RBSB-334 |
|
|
– DL rate matching restriction information |
Not Present |
RBSB-335 |
|
|
– Spreading factor |
128 |
RBSB-336 |
|
|
– Number of bits for Pilot bits(SF=128,256) |
4 |
RBSB-337 |
|
|
– Fixed or Flexible Position |
Fixed |
RBSB-338 |
|
|
– TFCI existence |
FALSE |
RBSB-339 |
|
|
– DPCH compressed mode info |
Not Present |
RBSB-340 |
|
|
– TX Diversity mode |
None |
RBSB-341 |
|
|
– SSDT information |
Not Present |
R99 and Rel-4 only |
RBSB-342 |
|
– Default DPCH Offset Value |
Not Present |
RBSB-343 |
|
|
Downlink information for each radio link list |
RBSB-344 |
||
|
– Primary CPICH info |
RBSB-345 |
||
|
– Primary scrambling code |
Reference to clause 6.1 "Default settings (FDD)" |
RBSB-346 |
|
|
– PDSCH with SHO DCH info |
Not Present |
R99 and Rel-4 only |
RBSB-347 |
|
– PDSCH code mapping |
Not Present |
R99 and Rel-4 only |
RBSB-348 |
|
– Downlink DPCH info for each RL |
RBSB-349 |
||
|
– Primary CPICH usage for channel estimation |
Primary CPICH may be used |
RBSB-350 |
|
|
– DPCH frame offset |
Set to value Default DPCH Offset Value (as currently stored in SS) mod 38 400 |
RBSB-351 |
|
|
– Secondary CPICH info |
Not Present |
RBSB-352 |
|
|
– DL channelisation code |
RBSB-353 |
||
|
– Secondary scrambling code |
Not Present |
RBSB-354 |
|
|
– Spreading factor |
128 |
RBSB-355 |
|
|
– Code number |
96 |
RBSB-356 |
|
|
– Scrambling code change |
No change |
RBSB-357 |
|
|
– TPC combination index |
0 |
RBSB-358 |
|
|
– SSDT Cell Identity |
Not Present |
R99 and Rel-4 only |
RBSB-359 |
|
– Closed loop timing adjustment mode |
Not Present |
RBSB-360 |
|
|
– SCCPCH information for FACH |
Not Present |
R99 and Rel-4 only |
RBSB-361 |
|
MBMS PL Service Restriction Information |
Not Present |
Rel-6 |
RBSB-362 |
Contents of RADIO BEARER SETUP message: AM or UM (E-DCH and HSDPA)
|
Information Element |
Condition |
Value/remark |
Version |
Index |
|---|---|---|---|---|
|
Message Type |
A1, A2, A3 |
RBSE-001 |
||
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
RBSE-002 |
||
|
Integrity check info |
RBSE-003 |
|||
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
RBSE-004 |
||
|
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
RBSE-005 |
||
|
Integrity protection mode info |
Not Present |
RBSE-006 |
||
|
Ciphering mode info |
Not Present |
RBSE-007 |
||
|
Activation time |
A1 |
Not Present |
RBSE-008 |
|
|
Activation time |
A2, A3 |
(256+CFN-(CFN MOD 8 + 8))MOD 256 |
RBSE-009 |
|
|
New U-RNTI |
A1, A2, A3 |
Not Present |
RBSE-010 |
|
|
New C-RNTI |
Not Present |
RBSE-011 |
||
|
New DSCH-RNTI |
Not Present |
R99 and Rel-4 only |
RBSE-012 |
|
|
New H-RNTI |
‘1010 1010 1010 1010’ |
Rel-5 |
RBSE-013 |
|
|
New Primary E-RNTI |
‘1010 1010 1010 1010’ |
Rel-6 |
RBSE-014 |
|
|
New Secondary E-RNTI |
Not Present |
Rel-6 |
RBSE-015 |
|
|
RRC State indicator |
CELL_DCH |
RBSE-016 |
||
|
UTRAN DRX cycle length coefficient |
Not Present |
RBSE-017 |
||
|
CN information info |
Not Present |
RBSE-018 |
||
|
URA identity |
Not Present |
RBSE-019 |
||
|
CHOICE specification mode |
Complete specification |
Rel-6 |
RBSE-020 |
|
|
– Signalling RB information to setup |
Not Present |
RBSE-021 |
||
|
– RAB information for setup list |
RBSE-022 |
|||
|
– RAB information for setup |
RBSE-023 |
|||
|
– RAB info |
(high-speed UM DTCH for PS domain) |
RBSE-024 |
||
|
– RAB identity |
0000 0110B The first/ leftmost bit of the bit string contains the most significant bit of the RAB identity. |
RBSE-025 |
||
|
– CN domain identity |
PS domain |
RBSE-026 |
||
|
– NAS Synchronization Indicator |
Not Present |
RBSE-027 |
||
|
– Re-establishment timer |
useT315 |
RBSE-028 |
||
|
– RB information to setup |
RBSE-029 |
|||
|
– RB identity |
25 |
RBSE-030 |
||
|
– PDCP info |
Not present |
RBSE-031 |
||
|
– CHOICE RLC info type |
RLC info |
RBSE-032 |
||
|
– CHOICE Uplink RLC mode |
UM RLC |
RBSE-033 |
||
|
– Transmission RLC discard |
Not present |
RBSE-034 |
||
|
– CHOICE Downlink RLC mode |
UM RLC |
RBSE-035 |
||
|
– DL UM RLC LI size |
Selected with DL UM RLC data size |
Rel-5 |
RBSE-036 |
|
|
– DL Reception Window Size |
Not present |
Rel-6 |
RBSE-037 |
|
|
– One sided RLC re-establishment |
FALSE |
RBSE-038 |
||
|
– Alternative E-bit interpretation |
Not present |
Rel-6 |
RBSE-039 |
|
|
– RB mapping info |
RBSE-040 |
|||
|
– Information for each multiplexing option |
1 RBMuxOptions |
RBSE-041 |
||
|
– RLC logical channel mapping indicator |
Not Present |
RBSE-042 |
||
|
– Number of uplink RLC logical channels |
1 |
RBSE-043 |
||
|
– Uplink transport channel type |
E-DCH |
RBSE-044 |
||
|
– Logical channel identity |
7 |
RBSE-045 |
||
|
– E-DCH MAC-d flow identity |
2 |
RBSE-046 |
||
|
– DDI |
5 |
RBSE-047 |
||
|
– RLC PDU size list |
1 RLC PDU size |
RBSE-048 |
||
|
– RLC PDU size |
336 bits |
RBSE-049 |
||
|
– Include in scheduling info |
TRUE |
RBSE-050 |
||
|
– MAC logical channel priority |
8 |
RBSE-051 |
||
|
– Downlink RLC logical channel info |
RBSE-052 |
|||
|
– Number of downlink RLC logical channels |
1 |
RBSE-053 |
||
|
– Downlink transport channel type |
HS-DSCH |
RBSE-054 |
||
|
– DL DCH Transport channel identity |
Not Present |
RBSE-055 |
||
|
– DL DSCH Transport channel identity |
Not Present |
RBSE-056 |
||
|
– CHOICE DL MAC header type |
MAC-hs |
Rel-7 |
RBSE-057 |
|
|
– DL HS-DSCH MAC-d flow identity |
0 |
RBSE-058 |
||
|
– Logical channel identity |
Not Present |
RBSE-059 |
||
|
RB information to reconfigure list |
Not Present |
Rel-6 |
RBSE-060 |
|
|
RB information to be affected |
A1 |
Not Present |
RBSE-061 |
|
|
RB information to be affected |
A2, A3 |
RBSE-062 |
||
|
– RB identity |
1 (UM DCCH for RRC) |
RBSE-063 |
||
|
– RB mapping info |
RBSE-064 |
|||
|
– Information for each multiplexing option |
1 RBMuxOption |
RBSE-065 |
||
|
– RLC logical channel mapping indicator |
Not Present |
RBSE-066 |
||
|
– Number of uplink RLC logical channels |
1 |
RBSE-067 |
||
|
– Uplink transport channel type |
E-DCH |
RBSE-068 |
||
|
– Logical channel identity |
1 |
RBSE-069 |
||
|
– E-DCH MAC-d flow identity |
1 |
RBSE-070 |
||
|
– DDI |
1 |
RBSE-071 |
||
|
– RLC PDU size list |
1 RLC PDU size |
RBSE-072 |
||
|
– RLC PDU size |
96 bits |
RBSE-073 |
||
|
– Include in scheduling info |
FALSE |
RBSE-074 |
||
|
– MAC logical channel priority |
1 |
RBSE-075 |
||
|
– Downlink RLC logical channel info |
RBSE-076 |
|||
|
– Number of RLC logical channels |
1 |
RBSE-077 |
||
|
– Downlink transport channel type |
DCH |
RBSE-078 |
||
|
– DL DCH Transport channel identity |
10 |
RBSE-079 |
||
|
– DL DSCH Transport channel identity |
Not Present |
RBSE-080 |
||
|
– Logical channel identity |
1 |
RBSE-081 |
||
|
– RB identity |
2 (AM DCCH for RRC) |
RBSE-082 |
||
|
– RB mapping info |
RBSE-083 |
|||
|
– Information for each multiplexing option |
1 RBMuxOption |
RBSE-084 |
||
|
– RLC logical channel mapping indicator |
Not Present |
RBSE-085 |
||
|
– Number of uplink RLC logical channels |
1 |
RBSE-086 |
||
|
– Uplink transport channel type |
E-DCH |
RBSE-087 |
||
|
– Logical channel identity |
2 |
RBSE-088 |
||
|
– E-DCH MAC-d flow identity |
1 |
RBSE-089 |
||
|
– DDI |
2 |
RBSE-090 |
||
|
– RLC PDU size list |
1 RLC PDU size |
RBSE-091 |
||
|
– RLC PDU size |
96 bits |
RBSE-092 |
||
|
– Include in scheduling info |
FALSE |
RBSE-093 |
||
|
– MAC logical channel priority |
2 |
RBSE-094 |
||
|
– Downlink RLC logical channel info |
RBSE-095 |
|||
|
– Number of RLC logical channels |
1 |
RBSE-096 |
||
|
– Downlink transport channel type |
DCH |
RBSE-097 |
||
|
– DL DCH Transport channel identity |
10 |
RBSE-098 |
||
|
– DL DSCH Transport channel identity |
Not Present |
RBSE-099 |
||
|
– Logical channel identity |
2 |
RBSE-100 |
||
|
– RB identity |
3 (AM DCCH for NAS High Priority) |
RBSE-101 |
||
|
– RB mapping info |
RBSE-102 |
|||
|
– Information for each multiplexing option |
1 RBMuxOption |
RBSE-103 |
||
|
– RLC logical channel mapping indicator |
Not Present |
RBSE-104 |
||
|
– Number of uplink RLC logical channels |
1 |
RBSE-105 |
||
|
– Uplink transport channel type |
E-DCH |
RBSE-106 |
||
|
– Logical channel identity |
3 |
RBSE-107 |
||
|
– E-DCH MAC-d flow identity |
1 |
RBSE-108 |
||
|
– DDI |
3 |
RBSE-109 |
||
|
– RLC PDU size list |
1 RLC PDU size |
RBSE-110 |
||
|
– RLC PDU size |
96 bits |
RBSE-111 |
||
|
– Include in scheduling info |
FALSE |
RBSE-112 |
||
|
– MAC logical channel priority |
3 |
RBSE-113 |
||
|
– Downlink RLC logical channel info |
RBSE-114 |
|||
|
– Number of RLC logical channels |
1 |
RBSE-115 |
||
|
– Downlink transport channel type |
DCH |
RBSE-116 |
||
|
– DL DCH Transport channel identity |
10 |
RBSE-117 |
||
|
– DL DSCH Transport channel identity |
Not Present |
RBSE-118 |
||
|
– Logical channel identity |
3 |
RBSE-119 |
||
|
– RB identity |
4 (AM DCCH for NAS Low Priority) |
RBSE-120 |
||
|
– RB mapping info |
RBSE-121 |
|||
|
– Information for each multiplexing option |
1 RBMuxOption |
RBSE-122 |
||
|
– RLC logical channel mapping indicator |
Not Present |
RBSE-123 |
||
|
– Number of uplink RLC logical channels |
1 |
RBSE-124 |
||
|
– Uplink transport channel type |
E-DCH |
RBSE-125 |
||
|
– Logical channel identity |
4 |
RBSE-126 |
||
|
– E-DCH MAC-d flow identity |
1 |
RBSE-127 |
||
|
– DDI |
4 |
RBSE-128 |
||
|
– RLC PDU size list |
1 RLC PDU size |
RBSE-129 |
||
|
– RLC PDU size |
96 bits |
RBSE-130 |
||
|
– Include in scheduling info |
FALSE |
RBSE-131 |
||
|
– MAC logical channel priority |
4 |
RBSE-132 |
||
|
– Downlink RLC logical channel info |
RBSE-133 |
|||
|
– Number of RLC logical channels |
1 |
RBSE-134 |
||
|
– Downlink transport channel type |
DCH |
RBSE-135 |
||
|
– DL DCH Transport channel identity |
10 |
RBSE-136 |
||
|
– DL DSCH Transport channel identity |
Not Present |
RBSE-137 |
||
|
– Logical channel identity |
4 |
RBSE-138 |
||
|
Downlink counter synchronization info |
A1, A2, A3 |
Not Present |
RBSE-139 |
|
|
PDCP ROHC target mode |
Not Present |
Rel-5 |
RBSE-140 |
|
|
UL Transport channel information for all transport channels |
Not Present |
RBSE-141 |
||
|
Deleted UL TrCH information |
A1 |
Not Present |
RBSE-142 |
|
|
Deleted UL TrCH information |
A2, A3 |
RBSE-143 |
||
|
– Uplink transport channel type |
DCH |
RBSE-144 |
||
|
– UL transport channel identity |
5 |
RBSE-145 |
||
|
Added or Reconfigured TrCH information list |
A1 |
1 TrCH added |
RBSE-146 |
|
|
– Added or Reconfigured UL TrCH information |
1 E-DCH added |
RBSE-147 |
||
|
– Uplink transport channel type |
E-DCH |
RBSE-148 |
||
|
– CHOICE UL parameters |
E-DCH |
RBSE-149 |
||
|
– E-DCH Transmission Time Interval |
10 ms |
RBSE-150 |
||
|
– HARQ info for E-DCH |
RBSE-151 |
|||
|
– HARQ RV Configuration |
Rv0 |
RBSE-152 |
||
|
– Added or reconfigured E-DCH MAC-d flow |
RBSE-153 |
|||
|
– E-DCH MAC-d flow identity |
2 |
RBSE-154 |
||
|
– E-DCH MAC-d flow power offset |
0 |
RBSE-155 |
||
|
– E-DCH MAC-d flow maximum number of retransmissions |
7 |
RBSE-156 |
||
|
– E-DCH MAC-d flow multiplexing list |
Not Present |
RBSE-157 |
||
|
– CHOICE transmission grant type |
Scheduled grant info |
RBSE-158 |
||
|
Added or Reconfigured UL TrCH information list |
A2, A3 |
1 TrCH added |
RBSE-159 |
|
|
– Added or Reconfigured UL TrCH information |
1 E-DCH added with one DCCH MAC-d flow and one DTCH MAC-d flow |
RBSE-160 |
||
|
– Uplink transport channel type |
E-DCH |
RBSE-161 |
||
|
– CHOICE UL parameters |
E-DCH |
RBSE-162 |
||
|
– E-DCH Transmission Time Interval |
(A2: 2ms), (A3 10ms) |
RBSE-163 |
||
|
– HARQ info for E-DCH |
RBSE-164 |
|||
|
– HARQ RV Configuration |
Rv0 |
RBSE-165 |
||
|
– Added or reconfigured E-DCH MAC-d flow |
(for DCCH) |
RBSE-166 |
||
|
– E-DCH MAC-d flow identity |
1 |
RBSE-167 |
||
|
– E-DCH MAC-d flow power offset |
0 |
RBSE-168 |
||
|
– E-DCH MAC-d flow maximum number of retransmissions |
7 |
RBSE-169 |
||
|
– E-DCH MAC-d flow multiplexing list |
Not Present |
RBSE-170 |
||
|
– CHOICE transmission grant type |
Non-scheduled grant info |
RBSE-171 |
||
|
– Max MAC-e PDU contents size |
114 bits |
RBSE-172 |
||
|
– 2 ms non-scheduled transmission grant HARQ process allocation |
Not Present |
RBSE-173 |
||
|
– Added or reconfigured E-DCH MAC-d flow |
(for DTCH) |
RBSE-174 |
||
|
– E-DCH MAC-d flow identity |
2 |
RBSE-175 |
||
|
– E-DCH MAC-d flow power offset |
0 |
RBSE-176 |
||
|
– E-DCH MAC-d flow maximum number of retransmissions |
7 |
RBSE-177 |
||
|
– E-DCH MAC-d flow multiplexing list |
Not Present |
RBSE-178 |
||
|
– CHOICE transmission grant type |
Scheduled grant info |
RBSE-179 |
||
|
CHOICE mode |
A1, A2, A3 |
Not Present |
R99 and Rel-4 only |
RBSE-180 |
|
DL Transport channel information common for all transport channels |
A1, A3 |
Not Present |
RBSE-181 |
|
|
DL Transport channel information common for all transport channels |
A2 |
RBSE-182 |
||
|
– SCCPCH TFCS |
Not Present |
RBSE-183 |
||
|
– CHOICE mode |
FDD |
RBSE-184 |
||
|
– CHOICE DL parameters |
Explicit |
RBSE-185 |
||
|
– DL DCH TFCS |
RBSE-186 |
|||
|
– CHOICE TFCI Signalling |
Normal |
RBSE-187 |
||
|
– TFCI Field 1 Information |
RBSE-188 |
|||
|
– CHOICE TFCS representation |
Complete reconfiguration |
RBSE-189 |
||
|
– TFCS complete reconfigure |
RBSE-190 |
|||
|
– CHOICE CTFC Size |
2 bit CTFC |
RBSE-191 |
||
|
– CTFC information |
2 TFCs |
RBSE-192 |
||
|
– 2bit CTFC |
0 |
RBSE-193 |
||
|
– Power offset Information |
RBSE-194 |
|||
|
– CHOICE Gain Factors |
computedGainFactors |
RBSE-195 |
||
|
– Reference TFC ID |
0 |
RBSE-196 |
||
|
– Power offset Pp-m |
Not Present |
RBSE-197 |
||
|
– 2bit CTFC |
1 |
RBSE-198 |
||
|
– Power offset Information |
RBSE-199 |
|||
|
– CHOICE Gain Factors |
signalledGainFactors |
RBSE-200 |
||
|
– CHOICE mode |
FDD |
RBSE-201 |
||
|
– Gain factor ßc |
15 |
RBSE-202 |
||
|
– Gain factor ßd |
15 |
RBSE-203 |
||
|
– Reference TFC ID |
0 |
RBSE-204 |
||
|
– CHOICE mode |
FDD |
RBSE-205 |
||
|
– Power offset Pp-m |
Not Present |
RBSE-206 |
||
|
Deleted TrCH information list |
A1, A2, A3 |
Not Present |
RBSE-207 |
|
|
Added or Reconfigured TrCH information list |
A1, A3 |
1 TrCH added |
RBSE-208 |
|
|
– Added or Reconfigured DL TrCH information |
HS-DSCH for DTCH added |
RBSE-209 |
||
|
– Downlink transport channel type |
HS-DSCH |
RBSE-210 |
||
|
– DL Transport channel identity |
Not Present |
RBSE-211 |
||
|
– CHOICE DL parameters |
HS-DSCH |
RBSE-212 |
||
|
– HARQ Info |
RBSE-213 |
|||
|
– Number of Processes |
Reference to TS34.121 [2] Annex C Fixed Reference Channels |
RBSE-214 |
||
|
– CHOICE Memory Partitioning |
Explicit |
RBSE-215 |
||
|
– Memory size |
Reference to TS34.121 [2] Annex C Fixed Reference Channels parameter “Number of HARQ Processes". |
RBSE-216 |
||
|
– Process Memory Size |
Reference to TS34.121 [2] Annex C Fixed Reference Channels parameter “Number of SML’s per HARQ Proc.”. |
RBSE-217 |
||
|
– Additional memory sizes for MIMO |
Not Present |
Rel-7 |
RBSE-218 |
|
|
– CHOICE DL MAC header type |
MAC-hs |
Rel-7 |
RBSE-219 |
|
|
– Added or reconfigured MAC-d flow |
RBSE-220 |
|||
|
– MAC-hs queue to add or reconfigure list |
(one queue) |
RBSE-221 |
||
|
– MAC-hs queue Id |
0 |
RBSE-222 |
||
|
– MAC-d Flow Identity |
0 |
RBSE-223 |
||
|
– T1 |
50 |
RBSE-224 |
||
|
– MAC-hs window size |
16 |
RBSE-225 |
||
|
– MAC-d PDU size Info |
RBSE-226 |
|||
|
– MAC-d PDU size |
Reference to TS34.121 [2] Annex C Fixed Reference Channels |
RBSE-227 |
||
|
– MAC-d PDU size index |
0 |
RBSE-228 |
||
|
– MAC-hs queue to delete list |
Not present |
RBSE-229 |
||
|
– DCH quality target |
Not present |
RBSE-230 |
||
|
Added or Reconfigured DL TrCH information |
A2 |
2 TrCHs (DCH for DCCH and HS-DSCH for DTCH) |
RBSE-231 |
|
|
RBSE-232 |
||||
|
– Downlink transport channel type |
DCH |
RBSE-233 |
||
|
– DL Transport channel identity |
10 |
RBSE-234 |
||
|
– CHOICE DL parameters |
Explicit |
RBSE-235 |
||
|
– TFS |
RBSE-236 |
|||
|
– CHOICE Transport channel type |
Dedicated transport channels |
RBSE-237 |
||
|
– Dynamic Transport format information |
RBSE-238 |
|||
|
– RLC Size |
96 bits |
RBSE-239 |
||
|
– Number of TBs and TTI List |
2 |
RBSE-240 |
||
|
– Transmission Time Interval |
Not Present |
RBSE-241 |
||
|
– Number of Transport blocks |
0 |
RBSE-242 |
||
|
– Transmission Time Interval |
Not Present |
RBSE-243 |
||
|
– Number of Transport blocks |
1 |
RBSE-244 |
||
|
– CHOICE Logical channel list |
ALL |
RBSE-245 |
||
|
– Semi-static Transport Format information |
RBSE-246 |
|||
|
– Transmission time interval |
40 |
RBSE-247 |
||
|
– Type of channel coding |
Convolutional |
RBSE-248 |
||
|
– Coding Rate |
1/3 |
RBSE-249 |
||
|
– Rate matching attribute |
256 |
RBSE-250 |
||
|
– CRC size |
12 |
RBSE-251 |
||
|
– DCH quality target |
RBSE-252 |
|||
|
– BLER Quality value |
-20 (-2.0) |
RBSE-253 |
||
|
– Downlink transport channel type |
HS-DSCH |
RBSE-254 |
||
|
– DL Transport channel identity |
Not Present |
RBSE-255 |
||
|
– CHOICE DL parameters |
HS-DSCH |
RBSE-256 |
||
|
– HARQ Info |
RBSE-257 |
|||
|
– Number of Processes |
Reference to TS34.121 [2] Annex C Fixed Reference Channels |
RBSE-258 |
||
|
– CHOICE Memory Partitioning |
Explicit |
RBSE-259 |
||
|
– Memory size |
Reference to TS34.121 [2] Annex C Fixed Reference Channels parameter “Number of HARQ Processes". |
RBSE-260 |
||
|
– Process Memory Size |
Reference to TS34.121 [2] Annex C Fixed Reference Channels parameter “Number of SML’s per HARQ Proc.”. |
RBSE-261 |
||
|
– Additional memory sizes for MIMO |
Not Present |
Rel-7 |
RBSE-262 |
|
|
– CHOICE DL MAC header type |
MAC-hs |
Rel-7 |
RBSE-263 |
|
|
– Added or reconfigured MAC-d flow |
RBSE-264 |
|||
|
– MAC-hs queue to add or reconfigure list |
(one queue) |
RBSE-265 |
||
|
– MAC-hs queue Id |
0 |
RBSE-266 |
||
|
– MAC-d Flow Identity |
0 |
RBSE-267 |
||
|
– T1 |
50 |
RBSE-268 |
||
|
– MAC-hs window size |
16 |
RBSE-269 |
||
|
– MAC-d PDU size Info |
RBSE-270 |
|||
|
– MAC-d PDU size |
Reference to TS34.121 [2] Annex C Fixed Reference Channels |
RBSE-271 |
||
|
– MAC-d PDU size index |
0 |
RBSE-272 |
||
|
– MAC-hs queue to delete list |
Not present |
RBSE-273 |
||
|
– DCH quality target |
Not present |
RBSE-274 |
||
|
Frequency info |
A1, A2, A3 |
Not present |
RBSE-275 |
|
|
Multi-frequency Info |
Not present |
Rel-7 |
RBSE-276 |
|
|
DTX-DRX timing information |
Not present |
Rel-7 |
RBSE-277 |
|
|
DRX Information |
Not present |
Rel-7 |
RBSE-278 |
|
|
HS-SCCH less Information |
Not present |
Rel-7 |
RBSE-279 |
|
|
MIMO parameters |
Not present |
Rel-7 |
RBSE-280 |
|
|
Maximum allowed UL TX power |
33dBm |
RBSE-281 |
||
|
CHOICE channel requirement |
Uplink DPCH info |
Rel-5 and earlier |
RBSE-282 |
|
|
Uplink DPCH info |
Rel-6 |
RBSE-283 |
||
|
– Uplink DPCH power control info |
RBSE-284 |
|||
|
– DPCCH power offset |
-40 (-80dB) |
RBSE-285 |
||
|
– PC Preamble |
1 frame |
RBSE-286 |
||
|
– SRB delay |
7 frames |
RBSE-287 |
||
|
– Power Control Algorithm |
Algorithm1 |
RBSE-288 |
||
|
– TPC step size |
0 (1dB) |
RBSE-289 |
||
|
– ACK |
3 |
RBSE-290 |
||
|
– NACK |
3 |
RBSE-291 |
||
|
– Ack-Nack repetition factor |
1 |
RBSE-292 |
||
|
– HARQ_preamble_mode |
0 |
RBSE-293 |
||
|
– Scrambling code type |
Long |
RBSE-294 |
||
|
– Scrambling code number |
0 (0 to 16777215) |
RBSE-295 |
||
|
– Number of DPDCH |
A1 |
Not Present(1) |
RBSE-296 |
|
|
– spreading factor |
Reference to clause 6.10 Parameter Set |
RBSE-297 |
||
|
– TFCI existence |
Reference to clause 6.10 Parameter Set |
RBSE-298 |
||
|
– Number of FBI bit |
Reference to clause 6.10 Parameter Set |
RBSE-299 |
||
|
– Puncturing Limit |
Reference to clause 6.10 Parameter Set |
RBSE-300 |
||
|
– Number of DPDCH |
A2, A3 |
0 |
RBSE-301 |
|
|
– spreading factor |
Not present |
RBSE-302 |
||
|
– TFCI existence |
FALSE |
RBSE-303 |
||
|
– Number of FBI bit |
Not present |
RBSE-304 |
||
|
– Puncturing Limit |
Not present |
RBSE-305 |
||
|
E-DCH info |
A1, A2, A3 |
Rel-6 |
RBSE-306 |
|
|
– MAC-es/e reset indicator |
TRUE |
RBSE-307 |
||
|
– E-DPCCH info |
RBSE-308 |
|||
|
– E-DPCCH/DPCCH power offset |
0 |
RBSE-309 |
||
|
– Happy bit delay condition |
100 ms |
RBSE-310 |
||
|
– E-TFCI boost info |
Not present |
Rel-7 |
RBSE-311 |
|
|
– E-TFCI BetaED SwitchE-DPDCH power interpolation |
Not present |
Rel-7 |
RBSE-312 |
|
|
– E-DPDCH info |
A1, A3 |
RBSE-313 |
||
|
– E-TFCI table index |
0 |
RBSE-314 |
||
|
– E-DCH minimum set E-TFCI |
9 |
RBSE-315 |
||
|
– Reference E-TFCIs |
1 E-TFCI |
RBSE-316 |
||
|
– Reference E-TFCI |
11 |
RBSE-317 |
||
|
– Reference E-TFCI PO |
4 |
RBSE-318 |
||
|
– Maximum channelisation codes |
2sf4 |
RBSE-319 |
||
|
– PLnon-max |
0.84 |
RBSE-320 |
||
|
– Scheduling Information Configuration |
RBSE-321 |
|||
|
– Periodicity for Scheduling Info – no grant |
Not present |
RBSE-322 |
||
|
– Periodicity for Scheduling Info – grant |
Not present |
RBSE-323 |
||
|
– Power Offset for Scheduling Info |
0 |
RBSE-324 |
||
|
– 3-Index-Step Threshold |
Not present |
RBSE-325 |
||
|
– 2-Index-Step Threshold |
Not present |
RBSE-326 |
||
|
– E-DPDCH info |
A2 |
RBSE-327 |
||
|
– E-TFCI table index |
0 |
RBSE-328 |
||
|
– E-DCH minimum set E-TFCI |
9 |
RBSE-329 |
||
|
– Reference E-TFCIs |
2 E-TFCI |
RBSE-330 |
||
|
– Reference E-TFCI |
11 |
RBSE-331 |
||
|
– Reference E-TFCI PO |
4 |
RBSE-332 |
||
|
– Reference E-TFCI |
83 |
RBSE-333 |
||
|
– Reference E-TFCI PO |
16 |
RBSE-334 |
||
|
– Maximum channelisation codes |
2sf2and2sf4 |
RBSE-335 |
||
|
– PLnon-max |
0.84 |
RBSE-336 |
||
|
– Scheduling Information Configuration |
RBSE-337 |
|||
|
– Periodicity for Scheduling Info – no grant |
Not present |
RBSE-338 |
||
|
– Periodicity for Scheduling Info – grant |
Not present |
RBSE-339 |
||
|
– Power Offset for Scheduling Info |
0 |
RBSE-340 |
||
|
– 3-Index-Step Threshold |
Not present |
RBSE-341 |
||
|
– 2-Index-Step Threshold |
Not present |
RBSE-342 |
||
|
– Scheduled Transmission configuration |
A1, A2, A3 |
RBSE-343 |
||
|
– 2ms scheduled transmission grant HARQ process allocation |
Not present |
RBSE-344 |
||
|
– Serving Grant |
Not present |
RBSE-345 |
||
|
– UL 16QAM settings |
Not present |
Rel-7 |
RBSE-346 |
|
|
CHOICE Mode |
FDD |
R99 and Rel-4 only |
RBSE-347 |
|
|
– Downlink PDSCH information |
Not Present |
R99 and Rel-4 only |
RBSE-348 |
|
|
Downlink HS-PDSCH Information |
RBSE-349 |
|||
|
– HS-SCCH Info |
RBSE-350 |
|||
|
– CHOICE mode |
FDD |
RBSE-351 |
||
|
– DL Scrambling Code |
Not present |
RBSE-352 |
||
|
– HS-SCCH Channelisation Code Information |
RBSE-353 |
|||
|
– HS-SCCH Channelisation Code |
2 |
RBSE-354 |
||
|
– HS-SCCH Channelisation Code |
3 |
RBSE-355 |
||
|
– Measurement Feedback Info |
RBSE-356 |
|||
|
– CHOICE mode |
FDD |
RBSE-357 |
||
|
– POhsdsch |
6 dB |
RBSE-358 |
||
|
– CQI Feedback cycle, k |
2 ms |
RBSE-359 |
||
|
– CQI repetition factor |
1 |
RBSE-360 |
||
|
– CQI |
5 (corresponds to 0dB in relative power offset) |
RBSE-361 |
||
|
– CHOICE mode |
FDD |
RBSE-362 |
||
|
– Downlink 64QAM configured |
Not Present |
Rel-7 |
RBSE-363 |
|
|
Downlink information common for all radio links |
A1, A3 |
Not Present |
RBSE-364 |
|
|
Downlink information common for all radio links |
A2 |
RBSE-365 |
||
|
– Downlink DPCH info common for all RL |
RBSE-366 |
|||
|
– Timing indicator |
Maintain |
RBSE-367 |
||
|
– CFN-targetSFN frame offset |
Not Present |
RBSE-368 |
||
|
– Downlink DPCH power control information |
RBSE-369 |
|||
|
– DPC mode |
0 (single) |
RBSE-370 |
||
|
– CHOICE mode |
FDD |
RBSE-371 |
||
|
– Power offset PPilot-DPDCH |
0 |
RBSE-372 |
||
|
– DL rate matching restriction information |
Not Present |
RBSE-373 |
||
|
– Spreading factor |
256 |
RBSE-374 |
||
|
– Fixed or Flexible Position |
Fixed |
RBSE-375 |
||
|
– TFCI existence |
FALSE |
RBSE-376 |
||
|
– CHOICE SF |
256 |
RBSE-377 |
||
|
– Number of bits for Pilot bits |
8 |
RBSE-378 |
||
|
– CHOICE mode |
FDD |
RBSE-379 |
||
|
– DPCH compressed mode info |
Not Present |
RBSE-380 |
||
|
– TX Diversity mode |
None |
RBSE-381 |
||
|
– Default DPCH Offset Value |
Not Present |
RBSE-382 |
||
|
– MAC-hs reset indicator |
Not Present |
RBSE-383 |
||
|
– Post-verification period |
Not Present |
RBSE-384 |
||
|
Downlink information for each radio link list |
A1, A2, A3 |
RBSE-385 |
||
|
– Downlink information for each radio link |
RBSE-386 |
|||
|
– Choice mode |
FDD |
RBSE-387 |
||
|
– Primary CPICH info |
RBSE-388 |
|||
|
– Primary scrambling code |
Ref. to clause 6.1 "Default settings (FDD)" |
RBSE-389 |
||
|
– PDSCH with SHO DCH info |
Not Present |
R99 and Rel-4 only |
RBSE-390 |
|
|
– PDSCH code mapping |
Not Present |
R99 and Rel-4 only |
RBSE-391 |
|
|
– Serving HS-DSCH radio link indicator |
TRUE |
RBSE-392 |
||
|
– Serving E-DCH radio link indicator |
TRUE |
RBSE-393 |
||
|
– Downlink DPCH info for each RL |
RBSE-394 |
|||
|
– CHOICE mode |
FDD |
RBSE-395 |
||
|
– Primary CPICH usage for channel estimation |
Primary CPICH may be used |
RBSE-396 |
||
|
– DPCH frame offset |
Set to value Default DPCH Offset Value (as currently stored in SS) mod 38 400 |
RBSE-397 |
||
|
– Secondary CPICH info |
Not Present |
RBSE-398 |
||
|
– DL channelisation code |
RBSE-399 |
|||
|
– Secondary scrambling code |
Not Present |
RBSE-400 |
||
|
– Spreading factor |
A1 |
Reference to clause 6.10 Parameter Set |
RBSE-401 |
|
|
– Code number |
96 |
RBSE-402 |
||
|
– Spreading factor |
A2, A3 |
256 |
RBSE-403 |
|
|
– Code number |
192 |
RBSE-404 |
||
|
– Scrambling code change |
A1, A2, A3 |
No code change |
RBSE-405 |
|
|
– TPC combination index |
0 |
RBSE-406 |
||
|
– SSDT Cell Identity |
Not Present |
R99 and Rel-4 only |
RBSE-407 |
|
|
– Closed loop timing adjustment mode |
Not Present |
RBSE-408 |
||
|
– E-AGCH Info |
Rel-6 |
RBSE-409 |
||
|
– E-AGCH Channelisation Code |
14 |
RBSE-410 |
||
|
– CHOICE E-HICH Information |
Rel-6 |
RBSE-411 |
||
|
– E-HICH Information |
RBSE-412 |
|||
|
– DL Scrambling code |
Not Present (default is primary) |
RBSE-413 |
||
|
– Channelisation code |
6 |
RBSE-414 |
||
|
– Signature sequence |
1 |
RBSE-415 |
||
|
– CHOICE E-RGCH Information |
Not Present |
Rel-6 |
RBSE-416 |
|
|
– SCCPCH information for FACH |
Not Present |
R99 and Rel-4 only |
RBSE-417 |
|
|
MBMS PL Service Restriction Information |
Not Present |
Rel-6 |
RBSE-418 |
|
Condition |
Explanation |
|
A1 |
Not using E-DCH 4codes except sub-test 5 in TS 34.121-1 [2] Table C.11.1.3 |
|
A2 |
Using E-DCH 4codes |
|
A3 |
Sub-test 5 in TS 34.121-1 [2] Table C.11.1.3 |
Contents of RADIO BEARER SETUP message: AM or UM (HSDPA with F-DPCH)
|
Information Element |
Value/remark |
Version |
Index |
|
|---|---|---|---|---|
|
Message Type |
|
Rel-6 |
RBSF-001 |
|
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
|
RBSF-002 |
|
|
Integrity check info |
|
|
RBSF-003 |
|
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
|
RBSF-004 |
|
|
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
|
RBSF-005 |
|
|
Integrity protection mode info |
Not Present |
|
RBSF-006 |
|
|
Ciphering mode info |
Not Present |
|
RBSF-007 |
|
|
Activation time |
(256+CFN-(CFN MOD 8 + 8))MOD 256 |
RBSF-008 |
||
|
New U-RNTI |
Not Present |
Rel-6 |
RBSF-009 |
|
|
New C-RNTI |
Not Present |
Rel-6 |
RBSF-010 |
|
|
New H-RNTI |
‘1010 1010 1010 1010’ |
Rel-6 |
RBSF-011 |
|
|
New Primary E-RNTI |
Not Present |
Rel-6 |
RBSF-012 |
|
|
New Secondary E-RNTI |
Not Present |
Rel-6 |
RBSF-013 |
|
|
RRC State indicator |
CELL_DCH |
Rel-6 |
RBSF-014 |
|
|
UTRAN DRX cycle length coefficient |
Not Present |
Rel-6 |
RBSF-015 |
|
|
CN information info |
Not Present |
|
RBSF-016 |
|
|
URA identity |
Not Present |
|
RBSF-017 |
|
|
CHOICE Specification mode |
Complete specification |
Rel-6 |
RBSF-018 |
|
|
– Signalling RB information to setup |
Not Present |
|
RBSF-019 |
|
|
– RAB information for setup |
RBSF-020 |
|||
|
– RAB info |
(high-speed UM DTCH for PS domain) |
RBSF-021 |
||
|
– RAB identity |
0000 0110B |
RBSF-022 |
||
|
– CN domain identity |
PS domain |
RBSF-023 |
||
|
– NAS Synchronization Indicator |
Not Present |
RBSF-024 |
||
|
– Re-establishment timer |
useT315 |
RBSF-025 |
||
|
– RB information to setup |
RBSF-026 |
|||
|
– RB identity |
25 |
RBSF-027 |
||
|
– PDCP info |
Not Present |
RBSF-028 |
||
|
– CHOICE RLC info type |
RLC info |
RBSF-029 |
||
|
– CHOICE Uplink RLC mode |
Not present |
RBSF-030 |
||
|
– CHOICE Downlink RLC mode |
UM RLC |
RBSF-031 |
||
|
– DL UM RLC LI size |
Selected with DL UM RLC data size |
Rel-5 |
RBSF-032 |
|
|
– One sided RLC re-establishment |
FALSE |
Rel-5 |
RBSF-033 |
|
|
– RB mapping info |
RBSF-034 |
|||
|
– Information for each multiplexing option |
1 RBMuxOption |
RBSF-035 |
||
|
– RLC logical channel mapping indicator |
Not Present |
RBSF-036 |
||
|
– Number of uplink RLC logical channels |
1 |
RBSF-037 |
||
|
– Downlink RLC logical channel info |
RBSF-038 |
|||
|
– Number of downlink RLC logical channels |
1 |
RBSF-039 |
||
|
– Downlink transport channel type |
HS-DSCH |
RBSF-040 |
||
|
– DL DCH Transport channel identity |
Not present |
RBSF-041 |
||
|
– DL DSCH Transport channel identity |
Not present |
RBSF-042 |
||
|
– CHOICE DL MAC header type |
MAC-hs |
Rel-7 |
RBSF-043 |
|
|
– DL HS-DSCH MAC-d flow identity |
1 |
RBSF-044 |
||
|
– Logical channel identity |
Not Present |
RBSF-045 |
||
|
RB information to reconfigure list |
Not Present |
Rel-6 |
RBSF-046 |
|
|
RB information to be affected |
Rel-6 |
RBSF-047 |
||
|
– RB identity |
1 (UM DCCH for RRC) |
RBSF-048 |
||
|
– RB mapping info |
RBSF-049 |
|||
|
– Information for each multiplexing option |
1 RBMuxOption |
RBSF-050 |
||
|
– RLC logical channel mapping indicator |
Not Present |
RBSF-051 |
||
|
– Number of uplink RLC logical channels |
1 |
RBSF-052 |
||
|
– Uplink transport channel type |
DCH |
RBSF-053 |
||
|
– UL Transport channel identity |
5 |
RBSF-054 |
||
|
– Logical channel identity |
1 |
RBSF-055 |
||
|
– CHOICE RLC size list |
Configured |
RBSF-056 |
||
|
– MAC logical channel priority |
1 |
RBSF-057 |
||
|
– Downlink RLC logical channel info |
RBSF-058 |
|||
|
– Number of RLC logical channels |
1 |
RBSF-059 |
||
|
– Downlink transport channel type |
HS-DSCH |
RBSF-060 |
||
|
– DL DCH Transport channel identity |
Not present |
RBSF-061 |
||
|
– DL DSCH Transport channel identity |
Not present |
RBSF-062 |
||
|
– CHOICE DL MAC header type |
MAC-hs |
Rel-7 |
RBSF-063 |
|
|
– DL HS-DSCH MAC-d flow identity |
0 |
RBSF-064 |
||
|
– Logical channel identity |
1 |
RBSF-065 |
||
|
– RB identity |
2 (AM DCCH for RRC) |
RBSF-066 |
||
|
– RB mapping info |
RBSF-067 |
|||
|
– Information for each multiplexing option |
1 RBMuxOption |
RBSF-068 |
||
|
– RLC logical channel mapping indicator |
Not Present |
RBSF-069 |
||
|
– Number of uplink RLC logical channels |
1 |
RBSF-070 |
||
|
– Uplink transport channel type |
DCH |
RBSF-071 |
||
|
– UL Transport channel identity |
5 |
RBSF-072 |
||
|
– Logical channel identity |
2 |
RBSF-073 |
||
|
– CHOICE RLC size list |
Configured |
RBSF-074 |
||
|
– MAC logical channel priority |
2 |
RBSF-075 |
||
|
– Downlink RLC logical channel info |
RBSF-076 |
|||
|
– Number of RLC logical channels |
1 |
RBSF-077 |
||
|
– Downlink transport channel type |
HS-DSCH |
RBSF-078 |
||
|
– DL DCH Transport channel identity |
Not Present |
RBSF-079 |
||
|
– DL DSCH Transport channel identity |
Not Present |
RBSF-080 |
||
|
– CHOICE DL MAC header type |
MAC-hs |
Rel-7 |
RBSF-081 |
|
|
– DL HS-DSCH MAC-d flow identity |
0 |
RBSF-082 |
||
|
– Logical channel identity |
2 |
RBSF-083 |
||
|
– RB identity |
3 (AM DCCH for NAS High Priority) |
RBSF-084 |
||
|
– RB mapping info |
RBSF-085 |
|||
|
– Information for each multiplexing option |
1 RBMuxOption |
RBSF-086 |
||
|
– RLC logical channel mapping indicator |
Not Present |
RBSF-087 |
||
|
– Number of uplink RLC logical channels |
1 |
RBSF-088 |
||
|
– Uplink transport channel type |
DCH |
RBSF-089 |
||
|
– UL Transport channel identity |
5 |
RBSF-090 |
||
|
– Logical channel identity |
3 |
RBSF-091 |
||
|
– CHOICE RLC size list |
Configured |
RBSF-092 |
||
|
– MAC logical channel priority |
3 |
RBSF-093 |
||
|
– Downlink RLC logical channel info |
RBSF-094 |
|||
|
– Number of RLC logical channels |
1 |
RBSF-095 |
||
|
– Downlink transport channel type |
HS-DSCH |
RBSF-096 |
||
|
– DL DCH Transport channel identity |
Not Present |
RBSF-097 |
||
|
– DL DSCH Transport channel identity |
Not Present |
RBSF-098 |
||
|
– CHOICE DL MAC header type |
MAC-hs |
Rel-7 |
RBSF-099 |
|
|
– DL HS-DSCH MAC-d flow identity |
0 |
RBSF-100 |
||
|
– Logical channel identity |
3 |
RBSF-101 |
||
|
– RB identity |
4 (AM DCCH for NAS Low Priority) |
RBSF-102 |
||
|
– RB mapping info |
RBSF-103 |
|||
|
– Information for each multiplexing option |
1 RBMuxOption |
RBSF-104 |
||
|
– RLC logical channel mapping indicator |
Not Present |
RBSF-105 |
||
|
– Number of uplink RLC logical channels |
1 |
RBSF-106 |
||
|
– Uplink transport channel type |
DCH |
RBSF-107 |
||
|
– UL Transport channel identity |
5 |
RBSF-108 |
||
|
– Logical channel identity |
4 |
RBSF-109 |
||
|
– CHOICE RLC size list |
Configured |
RBSF-110 |
||
|
– MAC logical channel priority |
4 |
RBSF-111 |
||
|
– Downlink RLC logical channel info |
RBSF-112 |
|||
|
– Number of RLC logical channels |
1 |
RBSF-113 |
||
|
– Downlink transport channel type |
HS-DSCH |
RBSF-114 |
||
|
– DL DCH Transport channel identity |
Not Present |
RBSF-115 |
||
|
– DL DSCH Transport channel identity |
Not Present |
RBSF-116 |
||
|
– CHOICE DL MAC header type |
MAC-hs |
Rel-7 |
RBSF-117 |
|
|
– DL HS-DSCH MAC-d flow identity |
0 |
RBSF-118 |
||
|
– Logical channel identity |
4 |
RBSF-119 |
||
|
Downlink counter synchronization info |
Not Present |
Rel-6 |
RBSF-120 |
|
|
PDCP ROHC target mode |
Not Present |
Rel-6 |
RBSF-121 |
|
|
UL Transport channel information for all transport channels |
Rel-6 |
RBSF-122 |
||
|
– PRACH TFCS |
Not Present |
RBSF-123 |
||
|
– CHOICE Mode |
FDD |
RBSF-124 |
||
|
– TFC subset |
Not Present |
RBSF-125 |
||
|
– UL DCH TFCS |
RBSF-126 |
|||
|
– CHOICE TFCI signalling |
Normal |
RBSF-127 |
||
|
– TFCI Field 1 information |
RBSF-128 |
|||
|
– CHOICE TFCS representation |
Complete reconfiguration |
RBSF-129 |
||
|
– TFCS complete reconfiguration information |
RBSF-130 |
|||
|
– CHOICE CTFC Size |
2 bit CTFC |
RBSF-131 |
||
|
– CTFC information |
2 TFCs |
RBSF-132 |
||
|
– 2bit CTFC |
0 |
RBSF-133 |
||
|
– Power offset Information |
RBSF-134 |
|||
|
– CHOICE Gain Factors |
computedGainFactors |
RBSF-135 |
||
|
– Reference TFC ID |
0 |
RBSF-136 |
||
|
– CHOICE mode |
FDD |
RBSF-137 |
||
|
– Power offset Pp-m |
Not Present |
RBSF-138 |
||
|
– 2bit CTFC |
1 |
RBSF-139 |
||
|
– Power offset Information |
RBSF-140 |
|||
|
– CHOICE Gain Factors |
signalledGainFactors |
RBSF-141 |
||
|
– CHOICE mode |
FDD |
RBSF-142 |
||
|
– Gain factor ßc |
15 |
RBSF-143 |
||
|
– Gain factor ßd |
15 |
RBSF-144 |
||
|
– Reference TFC ID |
0 |
RBSF-145 |
||
|
– CHOICE mode |
FDD |
RBSF-146 |
||
|
– Power offset Pp-m |
Not Present |
RBSF-147 |
||
|
Deleted UL TrCH information |
Not Present |
Rel-6 |
RBSF-148 |
|
|
Added or Reconfigured UL TrCH information |
Rel-6 |
RBSF-149 |
||
|
– Added or Reconfigured UL TrCH information |
RBSF-150 |
|||
|
– Uplink transport channel type |
DCH |
RBSF-151 |
||
|
– UL Transport channel identity |
5 |
RBSF-152 |
||
|
– TFS |
RBSF-153 |
|||
|
– CHOICE Transport channel type |
Dedicated transport channels |
RBSF-154 |
||
|
– Dynamic Transport Format Information |
RBSF-155 |
|||
|
– RLC size |
96 bits |
RBSF-156 |
||
|
– Number of TBs and TTI List |
2 |
RBSF-157 |
||
|
– Transmission Time Interval |
Not Present |
RBSF-158 |
||
|
– Number of Transport blocks |
0 |
RBSF-159 |
||
|
– Transmission Time Interval |
Not Present |
RBSF-160 |
||
|
– Number of Transport blocks |
1 |
RBSF-161 |
||
|
– CHOICE Logical channel List |
ALL |
RBSF-162 |
||
|
– Semi-static Transport Format Information |
RBSF-163 |
|||
|
– Transmission time interval |
40 |
RBSF-164 |
||
|
– Type of channel coding |
Convolutional |
RBSF-165 |
||
|
– Coding Rate |
1/3 |
RBSF-166 |
||
|
– Rate matching attribute |
256 |
RBSF-167 |
||
|
– CRC size |
12 |
RBSF-168 |
||
|
DL Transport channel information common for all transport channel |
Not Present |
Rel-6 |
RBSF-169 |
|
|
Deleted DL TrCH information |
Rel-6 |
RBSF-170 |
||
|
– Downlink transport channel type |
DCH |
RBSF-171 |
||
|
– DL Transport channel identity |
10 |
RBSF-172 |
||
|
Added or Reconfigured DL TrCH information |
1 TrCH (HS-DSCH for DTCH and DCCH) |
Rel-6 |
RBSF-173 |
|
|
– Downlink transport channel type |
HS-DSCH |
RBSF-174 |
||
|
– DL Transport channel identity |
Not Present |
RBSF-175 |
||
|
– CHOICE DL parameters |
HS-DSCH |
RBSF-176 |
||
|
– HARQ Info |
RBSF-177 |
|||
|
– Number of Processes |
Reference to TS34.121 [2] Annex C Fixed Reference Channels |
RBSF-178 |
||
|
– CHOICE Memory Partitioning |
Explicit |
RBSF-179 |
||
|
– Memory size |
Reference to TS34.121 [2] Annex C Fixed Reference Channels parameter “Number of HARQ Processes”. |
RBSF-180 |
||
|
– Process Memory Size |
Reference to TS34.121 [2] Annex C Fixed Reference Channels parameter “Number of SML’s per HARQ Proc.”. |
RBSF-181 |
||
|
– Additional memory sizes for MIMO |
Not Present |
Rel-7 |
RBSF-182 |
|
|
– CHOICE DL MAC header type |
MAC-hs |
Rel-7 |
RBSF-183 |
|
|
– Added or reconfigured MAC-d flow |
RBSF-184 |
|||
|
– MAC-hs queue to add or reconfigure list |
(two queues) |
RBSF-185 |
||
|
– MAC-hs queue Id |
0 (for DCCH) |
RBSF-186 |
||
|
– MAC-d Flow Identity |
0 |
RBSF-187 |
||
|
– T1 |
50 |
RBSF-188 |
||
|
– MAC-hs window size |
16 |
RBSF-189 |
||
|
– MAC-d PDU size Info |
RBSF-190 |
|||
|
– MAC-d PDU size |
100 |
RBSF-191 |
||
|
– MAC-d PDU size index |
0 |
RBSF-192 |
||
|
– MAC-hs queue Id |
1 (for DTCH) |
RBSF-193 |
||
|
– MAC-d Flow Identity |
1 |
RBSF-194 |
||
|
– T1 |
50 |
RBSF-195 |
||
|
– MAC-hs window size |
16 |
RBSF-196 |
||
|
– MAC-d PDU size Info |
RBSF-197 |
|||
|
– MAC-d PDU size |
Reference to TS34.121 [2] Annex C Fixed Reference Channels |
RBSF-198 |
||
|
– MAC-d PDU size index |
0 |
RBSF-199 |
||
|
– MAC-hs queue to delete list |
Not present |
RBSF-200 |
||
|
– DCH quality target |
Not present |
RBSF-201 |
||
|
Frequency info |
Not present |
RBSF-202 |
||
|
Multi-frequency Info |
Not present |
Rel-7 |
RBSF-203 |
|
|
DTX-DRX timing information |
Not present |
Rel-7 |
RBSF-204 |
|
|
DRX Information |
Not present |
Rel-7 |
RBSF-205 |
|
|
HS-SCCH less Information |
Not present |
Rel-7 |
RBSF-206 |
|
|
MIMO parameters |
Not present |
Rel-7 |
RBSF-207 |
|
|
Maximum allowed UL TX power |
33dBm |
RBSF-208 |
||
|
Uplink DPCH info |
Rel-6 |
RBSF-209 |
||
|
– Uplink DPCH power control info |
RBSF-210 |
|||
|
– DPCCH power offset |
-40 (-80dB) |
RBSF-211 |
||
|
– PC Preamble |
1 frame |
RBSF-212 |
||
|
– SRB delay |
7 frames |
RBSF-213 |
||
|
– Power Control Algorithm |
Algorithm1 |
RBSF-214 |
||
|
– TPC step size |
0 (1dB) |
RBSF-215 |
||
|
– ACK |
3 |
RBSF-216 |
||
|
– NACK |
3 |
RBSF-217 |
||
|
– Ack-Nack repetition factor |
1 |
RBSF-218 |
||
|
– HARQ_preamble_mode |
0 |
RBSF-219 |
||
|
– CHOICE mode |
FDD |
RBSF-220 |
||
|
– Scrambling code type |
Long |
RBSF-221 |
||
|
– Scrambling code number |
0 (0 to 16777215) |
RBSF-222 |
||
|
– Number of DPDCH |
Not Present (1) |
RBSF-223 |
||
|
– spreading factor |
256 |
RBSF-224 |
||
|
– TFCI existence |
TRUE |
RBSF-225 |
||
|
– Number of FBI bit |
Not Present(0) |
RBSF-226 |
||
|
– Puncturing Limit |
1 |
RBSF-227 |
||
|
E-DCH info |
Not Present |
Rel-6 |
RBSF-228 |
|
|
Downlink HS-PDSCH Information |
Rel-6 |
RBSF-229 |
||
|
– HS-SCCH Info |
RBSF-230 |
|||
|
– CHOICE mode |
FDD |
RBSF-231 |
||
|
– DL Scrambling Code |
Not present |
RBSF-232 |
||
|
– HS-SCCH Channelisation Code Information |
RBSF-233 |
|||
|
– HS-SCCH Channelisation Code |
2 |
RBSF-234 |
||
|
– Measurement Feedback Info |
RBSF-235 |
|||
|
– CHOICE mode |
FDD |
RBSF-236 |
||
|
– POhsdsch |
6 dB |
RBSF-237 |
||
|
– CQI Feedback cycle, k |
2 ms |
RBSF-238 |
||
|
– CQI repetition factor |
1 |
RBSF-239 |
||
|
– CQI |
5 (corresponds to 0dB in relative power offset) |
RBSF-240 |
||
|
– CHOICE mode |
FDD |
RBSF-241 |
||
|
– Downlink 64QAM configured |
Not Present |
Rel-7 |
RBSF-242 |
|
|
Downlink information common for all radio links |
Rel-6 |
RBSF-243 |
||
|
– Downlink F-DPCH info common for all RL |
RBSF-244 |
|||
|
– Timing Indication |
Maintain |
RBSF-245 |
||
|
– Timing maintained Synchronization indicator |
FALSE |
RBSF-246 |
||
|
– Downlink F-DPCH power control information |
RBSF-247 |
|||
|
– DPC mode |
0 (single) |
RBSF-248 |
||
|
– TPC command error rate target |
0.04 |
RBSF-249 |
||
|
– CHOICE mode |
FDD |
RBSF-250 |
||
|
– DPCH compressed mode info |
Not Present |
RBSF-251 |
||
|
– TX Diversity mode |
None |
RBSF-252 |
||
|
– Default DPCH Offset Value |
Not Present |
RBSF-253 |
||
|
– MAC-hs reset indicator |
Not Present |
RBSF-254 |
||
|
Downlink information for each radio link list |
Rel-6 |
RBSF-255 |
||
|
– Downlink information for each radio link |
RBSF-256 |
|||
|
– Choice mode |
FDD |
RBSF-257 |
||
|
– Primary CPICH info |
RBSF-258 |
|||
|
– Primary scrambling code |
Ref. to clause 6.1 "Default settings (FDD)" |
RBSF-259 |
||
|
– Serving HS-DSCH radio link indicator |
TRUE |
RBSF-260 |
||
|
– Downlink DPCH info for each RL |
Not Present |
RBSF-261 |
||
|
– Downlink F-DPCH info for each RL |
RBSF-262 |
|||
|
– Primary CPICH usage for channel estimation |
Primary CPICH may be used |
RBSF-263 |
||
|
– F-DPCH frame offset |
Set to value Default DPCH Offset Value (as currently stored in SS) mod 38 400 |
RBSF-264 |
||
|
– Secondary CPICH info |
Not Present |
RBSF-265 |
||
|
– Secondary scrambling code |
Not Present |
RBSF-266 |
||
|
– Code number |
6 |
RBSF-267 |
||
|
– TPC combination index |
0 |
RBSF-268 |
||
|
MBMS PL Service Restriction Information |
Not Present |
Rel-6 |
RBSF-269 |
|
Contents of RADIO BEARER SETUP message: AM or UM (DC-HSDPA)
|
Information Element |
Value/remark |
Version |
Index |
|---|---|---|---|
|
Message Type |
RBSD-001 |
||
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
RBSD-002 |
|
|
Integrity check info |
RBSD-003 |
||
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
RBSD-004 |
|
|
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
RBSD-005 |
|
|
Integrity protection mode info |
Not Present |
RBSD-006 |
|
|
Ciphering mode info |
Not Present |
RBSD-007 |
|
|
Activation time |
Not Present |
RBSD-008 |
|
|
New U-RNTI |
Not Present |
RBSD-009 |
|
|
New C-RNTI |
Not Present |
RBSD-010 |
|
|
New H-RNTI |
‘1010 1010 1010 1010’ |
Rel-5 |
RBSD-011 |
|
New Primary E-RNTI |
Not Present |
Rel-6 |
RBSD-012 |
|
New Secondary E-RNTI |
Not Present |
Rel-6 |
RBSD-013 |
|
RRC State indicator |
CELL_DCH |
RBSD-014 |
|
|
UTRAN DRX cycle length coefficient |
Not Present |
RBSD-015 |
|
|
CN information info |
Not Present |
RBSD-016 |
|
|
URA identity |
Not Present |
RBSD-017 |
|
|
CHOICE specification mode |
Complete specification |
Rel-6 |
RBSD-018 |
|
Signalling RB information to setup |
Not Present |
RBSD-019 |
|
|
RAB information for setup list |
RBSD-020 |
||
|
– RAB information for setup |
RBSD-021 |
||
|
– RAB info |
(high-speed UM DTCH for PS domain) |
RBSD-022 |
|
|
– RAB identity |
0000 0110B The first/ leftmost bit of the bit string contains the most significant bit of the RAB identity. |
RBSD-023 |
|
|
– CN domain identity |
PS domain |
RBSD-024 |
|
|
– NAS Synchronization Indicator |
Not Present |
RBSD-025 |
|
|
– Re-establishment timer |
UseT315 |
RBSD-026 |
|
|
– RB information to setup |
RBSD-027 |
||
|
– RB identity |
25 |
RBSD-028 |
|
|
– PDCP info |
Not Present |
RBSD-029 |
|
|
– CHOICE RLC info type |
RLC info |
RBSD-030 |
|
|
– CHOICE Uplink RLC mode |
Not Present |
RBSD-031 |
|
|
– CHOICE Downlink RLC mode |
UM RLC |
RBSD-032 |
|
|
– DL UM RLC LI size |
Selected with DL UM RLC data size |
Rel-5 |
RBSD-033 |
|
– One sided RLC re-establishment |
FALSE |
Rel-5 |
RBSD-034 |
|
– RB mapping info |
RBSD-035 |
||
|
– Information for each multiplexing option |
1 RBMuxOptions |
RBSD-036 |
|
|
– RLC logical channel mapping indicator |
Not Present |
RBSD-037 |
|
|
– Downlink RLC logical channel info |
RBSD-038 |
||
|
– Number of downlink RLC logical channels |
1 |
RBSD-039 |
|
|
– Downlink transport channel type |
HS-DSCH |
RBSD-040 |
|
|
– DL DCH Transport channel identity |
Not Present |
RBSD-041 |
|
|
– DL DSCH Transport channel identity |
Not Present |
RBSD-042 |
|
|
– CHOICE DL MAC header type |
MAC-ehs |
Rel-7 |
RBSD-043 |
|
– DL HS-DSCH MAC-ehs Queue Id |
0 |
RBSD-044 |
|
|
– Logical channel identity |
1 |
RBSD-045 |
|
|
RB information to reconfigure list |
Not Present |
Rel-6 |
RBSD-046 |
|
RB information to be affected list |
Not Present |
RBSD-047 |
|
|
Downlink counter synchronization info |
Not Present |
RBSD-048 |
|
|
PDCP ROHC target mode |
Not Present |
Rel-5 |
RBSD-049 |
|
UL Transport channel information for all transport channels |
RBSD-050 |
||
|
– PRACH TFCS |
Not Present |
RBSD-051 |
|
|
– CHOICE mode |
FDD |
RBSD-052 |
|
|
– TFC subset |
Not Present |
RBSD-053 |
|
|
– UL DCH TFCS |
RBSD-054 |
||
|
– CHOICE TFCI signalling |
Normal |
RBSD-055 |
|
|
– TFCI Field 1 information |
RBSD-056 |
||
|
– CHOICE TFCS representation |
Complete reconfiguration |
RBSD-057 |
|
|
– TFCS complete reconfigure information |
RBSD-058 |
||
|
– CHOICE CTFC Size |
2 bit CTFC |
RBSD-059 |
|
|
– CTFC information |
4 TFCs |
RBSD-060 |
|
|
– CTFC |
Reference to clause TS 34.121 clause C.2.1 Parameter Set |
RBSD-061 |
|
|
– Power offset information |
RBSD-062 |
||
|
– CHOICE Gain Factors |
Computed Gain Factors(The last TFC is set to Signalled Gain Factors) |
RBSD-063 |
|
|
– Gain factor βc |
8 (Not Present if the CHOICE Gain Factors is set to Computed Gain Factors) |
RBSD-064 |
|
|
– Gain factor βd |
15 (Not Present if the CHOICE Gain Factors is set to Computed Gain Factors) |
RBSD-065 |
|
|
– Reference TFC ID |
0 |
RBSD-066 |
|
|
– CHOICE mode |
FDD |
RBSD-067 |
|
|
– Power offset P p-m |
Not Present |
RBSD-068 |
|
|
Deleted UL TrCH information list |
Not Present |
RBSD-069 |
|
|
Added or Reconfigured TrCH information list |
Not Present |
RBSD-070 |
|
|
CHOICE mode |
Not Present |
RBSD-071 |
|
|
DL Transport channel information common for all transport channel |
RBSD-072 |
||
|
– SCCPCH TFCS |
Not Present |
RBSD-073 |
|
|
– CHOICE mode |
FDD |
RBSD-074 |
|
|
– CHOICE DL parameters |
Explicit |
RBSD-075 |
|
|
– DL DCH TFCS |
RBSD-076 |
||
|
– CHOICE TFCI Signalling |
Normal |
RBSD-077 |
|
|
– TFCI Field 1 Information |
RBSD-078 |
||
|
– CHOICE TFCS representation |
Complete reconfiguration |
RBSD-079 |
|
|
– TFCS complete reconfigure |
RBSD-080 |
||
|
– CHOICE CTFC Size |
2 bit CTFC |
RBSD-081 |
|
|
– CTFC information |
4 TFCs |
RBSD-082 |
|
|
– CTFC |
Reference to clause TS 34.121 clause C.3.1 Parameter Set |
RBSD-083 |
|
|
– Power offset information |
Not Present |
RBSD-084 |
|
|
Deleted DL TrCH information |
Not Present |
RBSD-085 |
|
|
Added or Reconfigured DL TrCH information list |
1 TrCHs added |
RBSD-086 |
|
|
– Added or Reconfigured DL TrCH information |
(HS-DSCH for DTCH) |
RBSD-087 |
|
|
– Downlink transport channel type |
HS-DSCH |
Rel-5 |
RBSD-088 |
|
– DL Transport channel identity |
Not Present |
RBSD-089 |
|
|
– CHOICE DL parameters |
HS-DSCH |
RBSD-090 |
|
|
– HARQ Info |
Rel-5 |
RBSD-091 |
|
|
– Number of Processes |
Reference to TS34.121 [2] Annex C Fixed Reference Channels |
RBSD-092 |
|
|
– CHOICE Memory Partitioning |
Explicit |
RBSD-093 |
|
|
– Memory size |
Reference to TS34.121 [2] Annex C Fixed Reference Channels parameter “Number of HARQ Processes”. |
RBSD-094 |
|
|
– Process Memory Size |
Reference to TS34.121 [2] Annex C Fixed Reference Channels parameter “Number of SML’s per HARQ Proc.”. |
RBSD-095 |
|
|
– Additional memory sizes for MIMO |
Not Present |
Rel-7 |
RBSD-096 |
|
– CHOICE DL MAC header type |
MAC-ehs |
Rel-7 |
RBSD-097 |
|
– Added or reconfigured MAC-ehs reordering queue |
RBSD-098 |
||
|
– MAC-ehs queue to add or reconfigure list |
(one queue) |
Rel-7 |
RBSD-099 |
|
– MAC-ehs queue Id |
0 |
RBSD-100 |
|
|
– T1 |
50 |
RBSD-101 |
|
|
– Treset |
Not Present |
RBSD-102 |
|
|
– MAC-ehs window size |
32 |
RBSD-103 |
|
|
– DCH quality target |
Not present |
RBSD-108 |
|
|
Frequency info |
Not Present |
RBSD-109 |
|
|
Multi-frequency Info |
Not present |
Rel-7 |
RBSD-110 |
|
DTX-DRX timing information |
Not present |
Rel-7 |
RBSD-111 |
|
DRX Information |
Not present |
Rel-7 |
RBSD-112 |
|
HS-SCCH less Information |
Not present |
Rel-7 |
RBSD-113 |
|
MIMO parameters |
Not present |
Rel-7 |
RBSD-114 |
|
Maximum allowed UL TX power |
33dBm |
RBSD-115 |
|
|
CHOICE channel requirement |
Uplink DPCH info |
Rel-5 and earlier |
RBSD-116 |
|
Uplink DPCH info |
Rel-6 |
RBSD-117 |
|
|
– Uplink DPCH power control info |
RBSD-118 |
||
|
– CHOICE mode |
FDD |
RBSD-119 |
|
|
– DPCCH power offset |
-40 (-80dB) IE value will have no effect on the UE UL power when closed loop power control is active |
RBSD-120 |
|
|
– PC Preamble |
1 frame |
RBSD-121 |
|
|
– SRB delay |
7 frames |
RBSD-122 |
|
|
– Power Control Algorithm |
Algorithm1 |
RBSD-123 |
|
|
– TPC step size |
0 (1dB) |
RBSD-124 |
|
|
– ACK |
3 |
Rel-5 |
RBSD-125 |
|
– NACK |
3 |
Rel-5 |
RBSD-126 |
|
– Ack-Nack repetition factor |
1 |
Rel-5 |
RBSD-127 |
|
– CHOICE mode |
FDD |
RBSD-128 |
|
|
– Scrambling code type |
Long |
RBSD-129 |
|
|
– Scrambling code number |
0 (0 to 16777215) |
RBSD-130 |
|
|
– Number of DPDCH |
Not Present (1) |
RBSD-131 |
|
|
– spreading factor |
64 |
RBSD-132 |
|
|
– TFCI existence |
TRUE |
RBSD-133 |
|
|
– Number of FBI bit |
Not Present(0) |
RBSD-134 |
|
|
– Puncturing Limit |
1 |
RBSD-135 |
|
|
E-DCH Info |
Not Present |
Rel-6 |
RBSD-136 |
|
Downlink HS-PDSCH Information |
RBSD-137 |
||
|
– HS-SCCH Info |
RBSD-138 |
||
|
– CHOICE mode |
FDD |
RBSD-139 |
|
|
– DL Scrambling Code |
RBSD-140 |
||
|
– HS-SCCH Channelisation Code Information |
RBSD-141 |
||
|
– HS-SCCH Channelisation Code |
2 |
RBSD-142 |
|
|
– HS-SCCH Channelisation Code |
3 |
RBSD-143 |
|
|
– Measurement Feedback Info |
RBSD-146 |
||
|
– CHOICE mode |
FDD |
RBSD-147 |
|
|
– Measurement Power Offset |
6 dB |
Rel-5 |
RBSD-148 |
|
– CQI Feedback cycle, k |
2 ms |
Rel-5 |
RBSD-149 |
|
– CQI repetition factor |
1 |
Rel-5 |
RBSD-150 |
|
– CQI |
5 (corresponds to 0dB in relative power offset) |
Rel-5 |
RBSD-151 |
|
– CHOICE mode |
FDD |
RBSD-152 |
|
|
– Downlink 64QAM configured |
Not Present |
Rel-7 |
RBSD-153 |
|
– HS-DSCH TB size table |
Not Present |
Rel-7 |
RBSD-153b |
|
Downlink information common for all radio links |
Not Present |
RBSD-154 |
|
|
Downlink information per radio link list |
RBSD-155 |
||
|
– Downlink information for each radio link |
RBSD-156 |
||
|
– CHOICE mode |
FDD |
RBSD-157 |
|
|
– Primary CPICH info |
RBSD-158 |
||
|
– Primary scrambling code |
Reference to clause 6.1 "Default settings (FDD)" |
RBSD-159 |
|
|
– Serving HS-DSCH radio link indicator |
TRUE |
Rel-5 |
RBSD-160 |
|
– Downlink DPCH info for each RL |
RBSD-161 |
||
|
– CHOICE mode |
FDD |
RBSD-162 |
|
|
– Primary CPICH usage for channel estimation |
Primary CPICH may be used |
RBSD-163 |
|
|
– DPCH frame offset |
Set to value Default DPCH Offset Value (as currently stored in SS) mod 38 400 |
RBSD-164 |
|
|
– Secondary CPICH info |
Not Present |
RBSD-165 |
|
|
– DL channelisation code |
RBSD-166 |
||
|
– Secondary scrambling code |
Not present |
RBSD-167 |
|
|
– Spreading factor |
128 |
RBSD-168 |
|
|
– Code number |
96 |
RBSD-169 |
|
|
– Scrambling code change |
No change |
RBSD-170 |
|
|
– TPC combination index |
0 |
RBSD-171 |
|
|
– Closed loop timing adjustment mode |
Not Present |
RBSD-172 |
|
|
Downlink secondary cell info FDD |
Rel-8 |
RBSD-173 |
|
|
– CHOICE Configuration info |
New configuration |
RBSD-174 |
|
|
– New H-RNTI |
‘1010 1010 1010 1010’ |
RBSD-175 |
|
|
– Downlink 64QAM configured |
Not Present |
RBSD-176 |
|
|
– HS-DSCH TB size table |
Not Present |
RBSD-177 |
|
|
– Primary CPICH info |
RBSD-178 |
||
|
– Primary scrambling code |
Ref. to the Default setting in clause 6.1 (FDD) |
RBSD-179 |
|
|
– DL Scrambling Code |
Not Present |
RBSD-180 |
|
|
– HS-SCCH Channelisation Code Information |
RBSD-181 |
||
|
– HS-SCCH Channelisation Code |
2 |
RBSD-182 |
|
|
– HS-SCCH Channelisation Code |
3 |
RBSD-183 |
|
|
– Measurement Power Offset |
6 dB |
RBSD-184 |
|
|
– UARFCN downlink (Nd) |
Reference to clause 5.1 Test frequencies |
RBSD-185 |
|
|
MBMS PL Service Restriction Information |
Not Present |
Rel-6 |
RBSD-186 |
Contents of RADIO BEARER SETUP message: AM or UM (DC-HSUPA)
|
Information Element |
Condition |
Value/remark |
Version |
Index |
||||
|---|---|---|---|---|---|---|---|---|
|
Message Type |
RBSE-001 |
|||||||
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
RBSE-002 |
||||||
|
Integrity check info |
RBSE-003 |
|||||||
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
RBSE-004 |
||||||
|
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
RBSE-005 |
||||||
|
Integrity protection mode info |
Not Present |
RBSE-006 |
||||||
|
Ciphering mode info |
Not Present |
RBSE-007 |
||||||
|
New U-RNTI |
Not Present |
RBSE-008 |
||||||
|
New C-RNTI |
Not Present |
RBSE-009 |
||||||
|
New DSCH-RNTI |
Not Present |
R99 and Rel-4 only |
RBSE-010 |
|||||
|
New H-RNTI |
‘1010 1010 1010 1010’ |
Rel-5 |
RBSE-011 |
|||||
|
New Primary E-RNTI |
‘1010 1010 1010 1010’ |
Rel-6 |
RBSE-012 |
|||||
|
New Secondary E-RNTI |
Not Present |
Rel-6 |
RBSE-013 |
|||||
|
RRC State indicator |
CELL_DCH |
RBSE-014 |
||||||
|
UTRAN DRX cycle length coefficient |
Not Present |
RBSE-015 |
||||||
|
CN information info |
Not Present |
RBSE-016 |
||||||
|
URA identity |
Not Present |
RBSE-017 |
||||||
|
CHOICE specification mode |
Complete specification |
Rel-6 |
RBSE-018 |
|||||
|
– Signalling RB information to setup |
Not Present |
RBSE-019 |
||||||
|
– RAB information for setup list |
RBSE-020 |
|||||||
|
– RAB information for setup |
RBSE-021 |
|||||||
|
– RAB info |
(high-speed UM DTCH for PS domain) |
RBSE-022 |
||||||
|
– RAB identity |
0000 0110B The first/ leftmost bit of the bit string contains the most significant bit of the RAB identity. |
RBSE-023 |
||||||
|
– CN domain identity |
PS domain |
RBSE-024 |
||||||
|
– NAS Synchronization Indicator |
Not Present |
RBSE-025 |
||||||
|
– Re-establishment timer |
useT315 |
RBSE-026 |
||||||
|
– RB information to setup |
RBSE-027 |
|||||||
|
– RB identity |
25 |
RBSE-028 |
||||||
|
– PDCP info |
Not present |
RBSE-029 |
||||||
|
– CHOICE RLC info type |
RLC info |
RBSE-030 |
||||||
|
– CHOICE Uplink RLC mode |
UM RLC |
RBSE-031 |
||||||
|
– Transmission RLC discard |
Not present |
RBSE-032 |
||||||
|
– CHOICE Downlink RLC mode |
UM RLC |
RBSE-033 |
||||||
|
– DL UM RLC LI size |
Selected with DL UM RLC data size |
Rel-5 |
RBSE-034 |
|||||
|
– DL Reception Window Size |
Not present |
Rel-6 |
RBSE-035 |
|||||
|
– One sided RLC re-establishment |
FALSE |
RBSE-036 |
||||||
|
– Alternative E-bit interpretation |
Not present |
Rel-6 |
RBSE-037 |
|||||
|
– RB mapping info |
RBSE-038 |
|||||||
|
– Information for each multiplexing option |
1 RBMuxOptions |
RBSE-039 |
||||||
|
– RLC logical channel mapping indicator |
Not Present |
RBSE-040 |
||||||
|
– Number of uplink RLC logical channels |
1 |
RBSE-041 |
||||||
|
– Uplink transport channel type |
E-DCH |
RBSE-042 |
||||||
|
– Logical channel identity |
7 |
RBSE-043 |
||||||
|
– E-DCH MAC-d flow identity |
2 |
RBSE-044 |
||||||
|
– DDI |
5 |
RBSE-045 |
||||||
|
– RLC PDU size list |
1 RLC PDU size |
RBSE-046 |
||||||
|
– RLC PDU size |
336 bits |
RBSE-047 |
||||||
|
– Include in scheduling info |
TRUE |
RBSE-048 |
||||||
|
– MAC logical channel priority |
8 |
RBSE-049 |
||||||
|
– Downlink RLC logical channel info |
RBSE-050 |
|||||||
|
– Number of downlink RLC logical channels |
1 |
RBSE-051 |
||||||
|
– Downlink transport channel type |
HS-DSCH |
RBSE-052 |
||||||
|
– DL DCH Transport channel identity |
Not Present |
RBSE-053 |
||||||
|
– DL DSCH Transport channel identity |
Not Present |
RBSE-054 |
||||||
|
– CHOICE DL MAC header type |
MAC-ehs |
Rel-7 |
RBSE-055 |
|||||
|
– DL HS-DSCH MAC-d flow identity |
0 |
RBSE-056 |
||||||
|
– Logical channel identity |
Not Present |
RBSE-057 |
||||||
|
RB information to reconfigure list |
Not Present |
Rel-6 |
RBSE-058 |
|||||
|
RB information to be affected |
RBSE-059 |
|||||||
|
– RB identity |
1 (UM DCCH for RRC) |
RBSE-060 |
||||||
|
– RB mapping info |
RBSE-061 |
|||||||
|
– Information for each multiplexing option |
1 RBMuxOption |
RBSE-062 |
||||||
|
– RLC logical channel mapping indicator |
Not Present |
RBSE-063 |
||||||
|
– Number of uplink RLC logical channels |
1 |
RBSE-064 |
||||||
|
– Uplink transport channel type |
E-DCH |
RBSE-065 |
||||||
|
– Logical channel identity |
1 |
RBSE-066 |
||||||
|
– E-DCH MAC-d flow identity |
1 |
RBSE-067 |
||||||
|
– DDI |
1 |
RBSE-068 |
||||||
|
– RLC PDU size list |
1 RLC PDU size |
RBSE-069 |
||||||
|
– RLC PDU size |
96 bits |
RBSE-070 |
||||||
|
– Include in scheduling info |
FALSE |
RBSE-071 |
||||||
|
– MAC logical channel priority |
1 |
RBSE-072 |
||||||
|
– Downlink RLC logical channel info |
RBSE-073 |
|||||||
|
– Number of RLC logical channels |
1 |
RBSE-074 |
||||||
|
– Downlink transport channel type |
DCH |
RBSE-075 |
||||||
|
– DL DCH Transport channel identity |
10 |
RBSE-076 |
||||||
|
– DL DSCH Transport channel identity |
Not Present |
RBSE-077 |
||||||
|
– Logical channel identity |
1 |
RBSE-078 |
||||||
|
– RB identity |
2 (AM DCCH for RRC) |
RBSE-079 |
||||||
|
– RB mapping info |
RBSE-080 |
|||||||
|
– Information for each multiplexing option |
1 RBMuxOption |
RBSE-081 |
||||||
|
– RLC logical channel mapping indicator |
Not Present |
RBSE-082 |
||||||
|
– Number of uplink RLC logical channels |
1 |
RBSE-083 |
||||||
|
– Uplink transport channel type |
E-DCH |
RBSE-084 |
||||||
|
– Logical channel identity |
2 |
RBSE-085 |
||||||
|
– E-DCH MAC-d flow identity |
1 |
RBSE-086 |
||||||
|
– DDI |
2 |
RBSE-087 |
||||||
|
– RLC PDU size list |
1 RLC PDU size |
RBSE-088 |
||||||
|
– RLC PDU size |
96 bits |
RBSE-089 |
||||||
|
– Include in scheduling info |
FALSE |
RBSE-090 |
||||||
|
– MAC logical channel priority |
2 |
RBSE-091 |
||||||
|
– Downlink RLC logical channel info |
RBSE-092 |
|||||||
|
– Number of RLC logical channels |
1 |
RBSE-093 |
||||||
|
– Downlink transport channel type |
DCH |
RBSE-094 |
||||||
|
– DL DCH Transport channel identity |
10 |
RBSE-095 |
||||||
|
– DL DSCH Transport channel identity |
Not Present |
RBSE-096 |
||||||
|
– Logical channel identity |
2 |
RBSE-097 |
||||||
|
– RB identity |
3 (AM DCCH for NAS High Priority) |
RBSE-098 |
||||||
|
– RB mapping info |
RBSE-099 |
|||||||
|
– Information for each multiplexing option |
1 RBMuxOption |
RBSE-100 |
||||||
|
– RLC logical channel mapping indicator |
Not Present |
RBSE-101 |
||||||
|
– Number of uplink RLC logical channels |
1 |
RBSE-102 |
||||||
|
– Uplink transport channel type |
E-DCH |
RBSE-103 |
||||||
|
– Logical channel identity |
3 |
RBSE-104 |
||||||
|
– E-DCH MAC-d flow identity |
1 |
RBSE-105 |
||||||
|
– DDI |
3 |
RBSE-106 |
||||||
|
– RLC PDU size list |
1 RLC PDU size |
RBSE-107 |
||||||
|
– RLC PDU size |
96 bits |
RBSE-108 |
||||||
|
– Include in scheduling info |
FALSE |
RBSE-109 |
||||||
|
– MAC logical channel priority |
3 |
RBSE-110 |
||||||
|
– Downlink RLC logical channel info |
RBSE-111 |
|||||||
|
– Number of RLC logical channels |
1 |
RBSE-112 |
||||||
|
– Downlink transport channel type |
DCH |
RBSE-113 |
||||||
|
– DL DCH Transport channel identity |
10 |
RBSE-114 |
||||||
|
– DL DSCH Transport channel identity |
Not Present |
RBSE-115 |
||||||
|
– Logical channel identity |
3 |
RBSE-116 |
||||||
|
– RB identity |
4 (AM DCCH for NAS Low Priority) |
RBSE-117 |
||||||
|
– RB mapping info |
RBSE-118 |
|||||||
|
– Information for each multiplexing option |
1 RBMuxOption |
RBSE-119 |
||||||
|
– RLC logical channel mapping indicator |
Not Present |
RBSE-120 |
||||||
|
– Number of uplink RLC logical channels |
1 |
RBSE-121 |
||||||
|
– Uplink transport channel type |
E-DCH |
RBSE-122 |
||||||
|
– Logical channel identity |
4 |
RBSE-123 |
||||||
|
– E-DCH MAC-d flow identity |
1 |
RBSE-124 |
||||||
|
– DDI |
4 |
RBSE-125 |
||||||
|
– RLC PDU size list |
1 RLC PDU size |
RBSE-126 |
||||||
|
– RLC PDU size |
96 bits |
RBSE-127 |
||||||
|
– Include in scheduling info |
FALSE |
RBSE-128 |
||||||
|
– MAC logical channel priority |
4 |
RBSE-129 |
||||||
|
– Downlink RLC logical channel info |
RBSE-130 |
|||||||
|
– Number of RLC logical channels |
1 |
RBSE-131 |
||||||
|
– Downlink transport channel type |
DCH |
RBSE-132 |
||||||
|
– DL DCH Transport channel identity |
10 |
RBSE-133 |
||||||
|
– DL DSCH Transport channel identity |
Not Present |
RBSE-134 |
||||||
|
– Logical channel identity |
4 |
RBSE-135 |
||||||
|
Downlink counter synchronization info |
Not Present |
RBSE-136 |
||||||
|
PDCP ROHC target mode |
Not Present |
Rel-5 |
RBSE-137 |
|||||
|
UL Transport channel information for all transport channels |
Not Present |
RBSE-138 |
||||||
|
Deleted UL TrCH information |
RBSE-139 |
|||||||
|
– Uplink transport channel type |
DCH |
RBSE-140 |
||||||
|
– UL transport channel identity |
5 |
RBSE-141 |
||||||
|
Added or Reconfigured UL TrCH information list |
1 TrCH added |
RBSE-142 |
||||||
|
– Added or Reconfigured UL TrCH information |
1 E-DCH added with one DCCH MAC-d flow and one DTCH MAC-d flow |
RBSE-143 |
||||||
|
– Uplink transport channel type |
E-DCH |
RBSE-144 |
||||||
|
– CHOICE UL parameters |
E-DCH |
RBSE-145 |
||||||
|
– UL MAC header type |
MAC-i/is |
Rel-8 |
RBSE-145a |
|||||
|
– E-DCH Transmission Time Interval |
2ms |
RBSE-146 |
||||||
|
– HARQ info for E-DCH |
RBSE-147 |
|||||||
|
– HARQ RV Configuration |
Rv0 |
RBSE-148 |
||||||
|
– Added or reconfigured E-DCH MAC-d flow |
(for DCCH) |
RBSE-149 |
||||||
|
– E-DCH MAC-d flow identity |
1 |
RBSE-150 |
||||||
|
– E-DCH MAC-d flow power offset |
0 |
RBSE-151 |
||||||
|
– E-DCH MAC-d flow maximum number of retransmissions |
7 |
RBSE-152 |
||||||
|
– E-DCH MAC-d flow multiplexing list |
Not Present |
RBSE-153 |
||||||
|
– CHOICE transmission grant type |
Non-scheduled grant info |
RBSE-154 |
||||||
|
– Max MAC-e PDU contents size |
114 bits |
RBSE-155 |
||||||
|
– 2 ms non-scheduled transmission grant HARQ process allocation |
Not Present |
RBSE-156 |
||||||
|
– Added or reconfigured E-DCH MAC-d flow |
(for DTCH) |
RBSE-157 |
||||||
|
– E-DCH MAC-d flow identity |
2 |
RBSE-158 |
||||||
|
– E-DCH MAC-d flow power offset |
0 |
RBSE-159 |
||||||
|
– E-DCH MAC-d flow maximum number of retransmissions |
7 |
RBSE-160 |
||||||
|
– E-DCH MAC-d flow multiplexing list |
Not Present |
RBSE-161 |
||||||
|
– CHOICE transmission grant type |
Scheduled grant info |
RBSE-162 |
||||||
|
CHOICE mode |
Not Present |
R99 and Rel-4 only |
RBSE-163 |
|||||
|
DL Transport channel information common for all transport channels |
Not Present |
RBSE-164 |
||||||
|
DL Transport channel information common for all transport channels |
RBSE-165 |
|||||||
|
– SCCPCH TFCS |
Not Present |
RBSE-166 |
||||||
|
– CHOICE mode |
FDD |
RBSE-167 |
||||||
|
– CHOICE DL parameters |
Explicit |
RBSE-168 |
||||||
|
– DL DCH TFCS |
RBSE-169 |
|||||||
|
– CHOICE TFCI Signalling |
Normal |
RBSE-170 |
||||||
|
– TFCI Field 1 Information |
RBSE-171 |
|||||||
|
– CHOICE TFCS representation |
Complete reconfiguration |
RBSE-172 |
||||||
|
– TFCS complete reconfigure |
RBSE-173 |
|||||||
|
– CHOICE CTFC Size |
2 bit CTFC |
RBSE-174 |
||||||
|
– CTFC information |
2 TFCs |
RBSE-175 |
||||||
|
– 2bit CTFC |
0 |
RBSE-176 |
||||||
|
– Power offset Information |
RBSE-177 |
|||||||
|
– CHOICE Gain Factors |
computedGainFactors |
RBSE-178 |
||||||
|
– Reference TFC ID |
0 |
RBSE-179 |
||||||
|
– Power offset Pp-m |
Not Present |
RBSE-180 |
||||||
|
– 2bit CTFC |
1 |
RBSE-181 |
||||||
|
– Power offset Information |
RBSE-182 |
|||||||
|
– CHOICE Gain Factors |
signalledGainFactors |
RBSE-183 |
||||||
|
– CHOICE mode |
FDD |
RBSE-184 |
||||||
|
– Gain factor ßc |
15 |
RBSE-185 |
||||||
|
– Gain factor ßd |
15 |
RBSE-186 |
||||||
|
– Reference TFC ID |
0 |
RBSE-187 |
||||||
|
– CHOICE mode |
FDD |
RBSE-188 |
||||||
|
– Power offset Pp-m |
Not Present |
RBSE-189 |
||||||
|
Deleted TrCH information list |
Not Present |
RBSE-190 |
||||||
|
Added or Reconfigured TrCH information list |
1 TrCH added |
RBSE-191 |
||||||
|
– Added or Reconfigured DL TrCH information |
HS-DSCH for DTCH added |
RBSE-192 |
||||||
|
– Downlink transport channel type |
HS-DSCH |
RBSE-193 |
||||||
|
– DL Transport channel identity |
Not Present |
RBSE-194 |
||||||
|
– CHOICE DL parameters |
HS-DSCH |
RBSE-195 |
||||||
|
– HARQ Info |
RBSE-196 |
|||||||
|
– Number of Processes |
Reference to TS34.121 [2] Annex C Fixed Reference Channels |
RBSE-197 |
||||||
|
– CHOICE Memory Partitioning |
Explicit |
RBSE-198 |
||||||
|
– Memory size |
Reference to TS34.121 [2] Annex C Fixed Reference Channels parameter “Number of HARQ Processes". |
RBSE-199 |
||||||
|
– Process Memory Size |
Reference to TS34.121 [2] Annex C Fixed Reference Channels parameter “Number of SML’s per HARQ Proc.”. |
RBSE-200 |
||||||
|
– Additional memory sizes for MIMO |
Not Present |
Rel-7 |
RBSE-201 |
|||||
|
– CHOICE DL MAC header type |
MAC-hs |
Rel-7 |
RBSE-202 |
|||||
|
– Added or reconfigured MAC-d flow |
RBSE-203 |
|||||||
|
– MAC-hs queue to add or reconfigure list |
(one queue) |
RBSE-204 |
||||||
|
– MAC-hs queue Id |
0 |
RBSE-205 |
||||||
|
– MAC-d Flow Identity |
0 |
RBSE-206 |
||||||
|
– T1 |
50 |
RBSE-207 |
||||||
|
– MAC-hs window size |
16 |
RBSE-208 |
||||||
|
– MAC-d PDU size Info |
RBSE-209 |
|||||||
|
– MAC-d PDU size |
Reference to TS34.121 [2] Annex C Fixed Reference Channels |
RBSE-210 |
||||||
|
– MAC-d PDU size index |
0 |
RBSE-211 |
||||||
|
– MAC-hs queue to delete list |
Not present |
RBSE-212 |
||||||
|
– DCH quality target |
Not present |
RBSE-213 |
||||||
|
Frequency info |
Not present |
RBSE-214 |
||||||
|
Multi-frequency Info |
Not present |
Rel-7 |
RBSE-215 |
|||||
|
DTX-DRX timing information |
Not present |
Rel-7 |
RBSE-216 |
|||||
|
DRX Information |
Not present |
Rel-7 |
RBSE-217 |
|||||
|
HS-SCCH less Information |
Not present |
Rel-7 |
RBSE-218 |
|||||
|
MIMO parameters |
Not present |
Rel-7 |
RBSE-219 |
|||||
|
Maximum allowed UL TX power |
33dBm |
RBSE-220 |
||||||
|
CHOICE channel requirement |
Uplink DPCH info |
Rel-5 and earlier |
RBSE-221 |
|||||
|
Uplink DPCH info |
Rel-6 |
RBSE-222 |
||||||
|
– Uplink DPCH power control info |
RBSE-223 |
|||||||
|
– DPCCH power offset |
-40 (-80dB) |
RBSE-224 |
||||||
|
– PC Preamble |
1 frame |
RBSE-225 |
||||||
|
– SRB delay |
7 frames |
RBSE-226 |
||||||
|
– Power Control Algorithm |
Algorithm1 |
RBSE-227 |
||||||
|
– TPC step size |
0 (1dB) |
RBSE-228 |
||||||
|
– ACK |
A1 |
0 |
RBSE-229 |
|||||
|
– ACK |
A2 |
6 |
RBSE-229a |
|||||
|
– NACK |
A1 |
0 |
RBSE-230 |
|||||
|
– NACK |
A2 |
6 |
RBSE-230a |
|||||
|
– Ack-Nack repetition factor |
1 |
RBSE-231 |
||||||
|
– HARQ_preamble_mode |
0 |
RBSE-232 |
||||||
|
– Scrambling code type |
Long |
RBSE-233 |
||||||
|
– Scrambling code number |
0 (0 to 16777215) |
RBSE-234 |
||||||
|
– Number of DPDCH |
0 |
RBSE-235 |
||||||
|
– spreading factor |
Not present |
RBSE-236 |
||||||
|
– TFCI existence |
FALSE |
RBSE-237 |
||||||
|
– Number of FBI bit |
Not present |
RBSE-238 |
||||||
|
– Puncturing Limit |
Not present |
RBSE-239 |
||||||
|
E-DCH info |
Rel-6 |
RBSE-240 |
||||||
|
– MAC-es/e reset indicator |
TRUE |
RBSE-241 |
||||||
|
– E-DPCCH info |
RBSE-242 |
|||||||
|
– E-DPCCH/DPCCH power offset |
0 |
RBSE-243 |
||||||
|
– Happy bit delay condition |
100 ms |
RBSE-244 |
||||||
|
– E-TFC Boost Info |
RBSE-244a |
|||||||
|
– E-TFCI boost |
67 |
Rel-7 |
RBSE-245 |
|||||
|
– Delta T2TP |
5 (15 dB) |
RBSE-245a |
||||||
|
– E-DPDCH power interpolation |
Not present |
Rel-7 |
RBSE-246 |
|||||
|
– E-DPDCH info |
RBSE-247 |
|||||||
|
– E-TFCI table index |
A1 |
0 |
RBSE-248 |
|||||
|
– E-TFCI table index |
A2 |
1 |
RBSE-248a |
|||||
|
– E-DCH minimum set E-TFCI |
67 |
RBSE-249 |
||||||
|
– Reference E-TFCIs |
2 E-TFCI |
RBSE-250 |
||||||
|
– Reference E-TFCI |
1 |
RBSE-251 |
||||||
|
– Reference E-TFCI PO |
12 |
RBSE-252 |
||||||
|
– Reference E-TFCI |
68 |
RBSE-252a |
||||||
|
– Reference E-TFCI PO |
19 |
RBSE-252b |
||||||
|
– Minimum reduced E-DPDCH gain factor. |
A1 |
30/15 |
Rel-8 |
RBSE-252c |
||||
|
– Minimum reduced E-DPDCH gain factor. |
A2 |
84/15 |
Rel-8 |
RBSE-252d |
||||
|
– Maximum channelisation codes |
2sf2and2sf4 |
RBSE-253 |
||||||
|
– PLnon-max |
0.84 |
RBSE-254 |
||||||
|
– Scheduling Information Configuration |
RBSE-255 |
|||||||
|
– Periodicity for Scheduling Info – no grant |
Not present |
RBSE-256 |
||||||
|
– Periodicity for Scheduling Info – grant |
Not present |
RBSE-257 |
||||||
|
– Power Offset for Scheduling Info |
0 |
RBSE-258 |
||||||
|
– 3-Index-Step Threshold |
Not present |
RBSE-259 |
||||||
|
– 2-Index-Step Threshold |
Not present |
RBSE-260 |
||||||
|
– Scheduled Transmission configuration |
RBSE-261 |
|||||||
|
– 2ms scheduled transmission grant HARQ process allocation |
Not present |
RBSE-262 |
||||||
|
– Serving Grant |
Not present |
RBSE-263 |
||||||
|
– UL 16QAM settings |
A1 |
Not present |
Rel-7 |
RBSE-264 |
||||
|
– UL 16QAM settings |
A2 |
Rel-7 |
RBSE-264a |
|||||
|
– BetaEd gain E-AGCH table selection |
1 |
RBSE-264b |
||||||
|
CHOICE Mode |
FDD |
R99 and Rel-4 only |
RBSE-265 |
|||||
|
– Downlink PDSCH information |
Not Present |
R99 and Rel-4 only |
RBSE-266 |
|||||
|
Uplink secondary cell info FDD |
Rel-9 |
RBSE-267 |
||||||
|
– Secondary serving E-DCH cell info |
RBSE-268 |
|||||||
|
– Primary E-RNTI |
‘1010 1010 1010 1010’ |
RBSE-269 |
||||||
|
– Secondary E-RNTI |
Not Present |
RBSE-270 |
||||||
|
– Secondary E-DCH info common |
RBSE-271 |
|||||||
|
– Frequency info |
RBSE-272 |
|||||||
|
– UARFCN uplink (Nu) |
Reference to clause 5.1 Test frequencies |
RBSE-273 |
||||||
|
– UARFCN downlink (Nd) |
Reference to clause 5.1 Test frequencies |
RBSE-274 |
||||||
|
– Scrambling code type |
Short |
RBSE-275 |
||||||
|
– Scrambling code number |
0 |
RBSE-276 |
||||||
|
– 2ms scheduled transmission grant HARQ process allocation |
Not Present |
RBSE-277 |
||||||
|
– Serving Grant |
RBSE-278 |
|||||||
|
– Primary/Secondary Grant Selector |
Primary |
RBSE-279 |
||||||
|
– Minimum reduced E-DPDCH gain factor |
A1 |
30/15 |
RBSE-280 |
|||||
|
– Minimum reduced E-DPDCH gain factor |
A2 |
84/15 |
RBSE-280a |
|||||
|
– E-DCH minimum set E-TFCI |
67 |
RBSE-281 |
||||||
|
– DPCCH Power offset for secondary UL frequency |
0 dB |
RBSE-282 |
||||||
|
– PC Preamble |
0 frame |
RBSE-283 |
||||||
|
– Downlink information per radio link list on secondary UL frequency |
RBSE-284 |
|||||||
|
– Downlink information for each radio link on secondary UL frequency |
1 |
RBSE-285 |
||||||
|
– Primary CPICH info |
RBSE-286 |
|||||||
|
– Primary scrambling code |
Ref. to the Default setting in clause 6.1 (FDD) |
RBSE-287 |
||||||
|
– Cell ID |
Not Present |
RBSE-288 |
||||||
|
– Downlink F-DPCH info for each RL on secondary UL frequency |
RBSE-289 |
|||||||
|
– Downlink F-DPCH info for each RL |
RBSE-290 |
|||||||
|
– Primary CPICH usage for channel estimate |
RBSE-291 |
|||||||
|
– F-DPCH frame offset |
Set to value Default DPCH Offset Value (as currently stored in SS) mod 38 400 |
RBSE-292 |
||||||
|
– F-DPCH slot format |
3 if UE supports enhanced F-DPCH, otherwise Not Present |
RBSE-293 |
||||||
|
– Secondary CPICH info |
Not Present |
RBSE-294 |
||||||
|
– Secondary scrambling code |
Not Present |
RBSE-295 |
||||||
|
– Code number |
12 |
RBSE-296 |
||||||
|
– TPC combination index |
0 |
RBSE-297 |
||||||
|
– STTD |
FALSE |
RBSE-298 |
||||||
|
– E-AGCH Info |
RBSE-299 |
|||||||
|
– E-AGCH Channelisation Code |
10 |
RBSE-300 |
||||||
|
– E-HICH Info |
RBSE-301 |
|||||||
|
– Channelisation Code |
4 |
RBSE-302 |
||||||
|
– Signature Sequence |
1 |
RBSE-303 |
||||||
|
– E-RGCH Info |
RBSE-304 |
|||||||
|
– Signature Sequence |
0 |
RBSE-305 |
||||||
|
– RG combination index |
0 |
RBSE-306 |
||||||
|
Downlink HS-PDSCH Information |
RBSE-307 |
|||||||
|
– HS-SCCH Info |
RBSE-308 |
|||||||
|
– CHOICE mode |
FDD |
RBSE-309 |
||||||
|
– DL Scrambling Code |
Not present |
RBSE-310 |
||||||
|
– HS-SCCH Channelisation Code Information |
RBSE-311 |
|||||||
|
– HS-SCCH Channelisation Code |
2 |
RBSE-312 |
||||||
|
– HS-SCCH Channelisation Code |
3 |
RBSE-313 |
||||||
|
– Measurement Feedback Info |
RBSE-314 |
|||||||
|
– CHOICE mode |
FDD |
RBSE-315 |
||||||
|
– POhsdsch |
6 dB |
RBSE-316 |
||||||
|
– CQI Feedback cycle, k |
2 ms |
RBSE-317 |
||||||
|
– CQI repetition factor |
1 |
RBSE-318 |
||||||
|
– CQI |
A1 |
0 |
RBSE-319 |
|||||
|
– CQI |
A2 |
6 |
RBSE-319a |
|||||
|
– CHOICE mode |
FDD |
RBSE-320 |
||||||
|
– Downlink 64QAM configured |
Not Present |
Rel-7 |
RBSE-321 |
|||||
|
Downlink information common for all radio links |
Not Present |
RBSE-322 |
||||||
|
Downlink information for each radio link list |
RBSE-323 |
|||||||
|
– Downlink information for each radio link |
RBSE-324 |
|||||||
|
– Choice mode |
FDD |
RBSE-325 |
||||||
|
– Primary CPICH info |
RBSE-326 |
|||||||
|
– Primary scrambling code |
Ref. to clause 6.1 "Default settings (FDD)" |
RBSE-327 |
||||||
|
– PDSCH with SHO DCH info |
Not Present |
R99 and Rel-4 only |
RBSE-328 |
|||||
|
– PDSCH code mapping |
Not Present |
R99 and Rel-4 only |
RBSE-329 |
|||||
|
– Serving HS-DSCH radio link indicator |
TRUE |
RBSE-330 |
||||||
|
– Serving E-DCH radio link indicator |
TRUE |
RBSE-331 |
||||||
|
– Downlink DPCH info for each RL |
RBSE-332 |
|||||||
|
– CHOICE mode |
FDD |
RBSE-333 |
||||||
|
– Primary CPICH usage for channel estimation |
Primary CPICH may be used |
RBSE-334 |
||||||
|
– DPCH frame offset |
Set to value Default DPCH Offset Value (as currently stored in SS) mod 38 400 |
RBSE-335 |
||||||
|
– Secondary CPICH info |
Not Present |
RBSE-336 |
||||||
|
– DL channelisation code |
RBSE-337 |
|||||||
|
– Secondary scrambling code |
Not Present |
RBSE-338 |
||||||
|
– Spreading factor |
256 |
RBSE-339 |
||||||
|
– Code number |
192 |
RBSE-340 |
||||||
|
– Scrambling code change |
No code change |
RBSE-341 |
||||||
|
– TPC combination index |
0 |
RBSE-342 |
||||||
|
– SSDT Cell Identity |
Not Present |
R99 and Rel-4 only |
RBSE-343 |
|||||
|
– Closed loop timing adjustment mode |
Not Present |
RBSE-344 |
||||||
|
– E-AGCH Info |
Rel-6 |
RBSE-345 |
||||||
|
– E-AGCH Channelisation Code |
14 |
RBSE-346 |
||||||
|
– CHOICE E-HICH Information |
Rel-6 |
RBSE-347 |
||||||
|
– E-HICH Information |
RBSE-348 |
|||||||
|
– DL Scrambling code |
Not Present (default is primary) |
RBSE-349 |
||||||
|
– Channelisation code |
6 |
RBSE-350 |
||||||
|
– Signature sequence |
1 |
RBSE-351 |
||||||
|
– CHOICE E-RGCH Information |
Not Present |
Rel-6 |
RBSE-352 |
|||||
|
– SCCPCH information for FACH |
Not Present |
R99 and Rel-4 only |
RBSE-353 |
|||||
|
Downlink secondary cell info FDD |
Rel-8 |
RBSE-354 |
||||||
|
– CHOICE Configuration info |
New configuration |
RBSE-355 |
||||||
|
– New H-RNTI |
‘1010 1010 1010 1010’ |
RBSE-356 |
||||||
|
– Downlink 64QAM configured |
Not Present |
RBSE-357 |
||||||
|
– HS-DSCH TB size table |
Not Present |
RBSE-358 |
||||||
|
– Primary CPICH info |
RBSE-359 |
|||||||
|
– Primary scrambling code |
Ref. to the Default setting in clause 6.1 (FDD) |
RBSE-360 |
||||||
|
– DL Scrambling Code |
Not Present |
RBSE-361 |
||||||
|
– HS-SCCH Channelisation Code Information |
RBSE-362 |
|||||||
|
– HS-SCCH Channelisation Code |
2 |
RBSE-363 |
||||||
|
– HS-SCCH Channelisation Code |
3 |
RBSE-364 |
||||||
|
– Measurement Power Offset |
6 dB |
RBSE-365 |
||||||
|
– UARFCN downlink (Nd) |
Reference to clause 5.1 Test frequencies |
RBSE-366 |
||||||
|
MBMS PL Service Restriction Information |
Not Present |
Rel-6 |
RBSE-367 |
|||||
|
Condition |
Explanation |
Version |
|
A1 |
This IE is used when test is performed with UL E-DCH reference measurement channel for DC-HSUPA using BPSK as specified in TS 34.121-1 subclause C.2.6 |
|
|
A2 |
This IE is used when test is performed with UL E-DCH reference measurement channel for DC-HSUPA using 16QAM as specified in TS 34.121-1 subclause C.2.7 |
Contents of RRC CONNECTION RELEASE message: UM
|
Information Element |
Value/remark |
Version |
|
Message Type |
||
|
U-RNTI |
This IE is set to the following value when the message is transmitted on the CCCH. When transmitted on DCCH, this is absent. |
R99, Rel-4 |
|
– SRNC identity |
0000 0000 0001B |
|
|
– S-RNTI |
0000 0000 0000 0000 0001B |
|
|
CHOICE identity type |
This IE is set to the following value when the message is transmitted on the CCCH. When transmitted on DCCH, this is absent. |
Rel-5 |
|
– U-RNTI |
||
|
– SRNC identity |
0000 0000 0001B |
|
|
– S-RNTI |
0000 0000 0000 0000 0001B |
|
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
|
|
Integrity check info |
This IE is present when this message is transmitted on downlink DCCH. Else, this IE and the sub-IEs are omitted. |
|
|
– Message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
|
|
– RRC Message sequence number |
SS provides the value of this IE, from its internal counter. |
|
|
N308 |
2 (for CELL_DCH state). Not Present (for UE in other connected mode states). |
|
|
Release cause |
Normal event |
|
|
Rplmn information |
Not Present |
|
|
Redirection info |
Not Present |
Rel-6 |
Contents of RRC CONNECTION SETUP message: UM
|
Information Element |
Condition |
Value/remark |
Version |
Index |
|---|---|---|---|---|
|
Message Type |
RCSU-001 |
|||
|
Initial UE identity |
Select the same identity as in the IE "Initial UE Identity" in received "RRC CONNECTION REQUEST" message |
RCSU-002 |
||
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
RCSU-003 |
||
|
Activation time |
Not Present(Now) |
RCSU-004 |
||
|
New U-RNTI |
RCSU-005 |
|||
|
– SRNC identity |
0000 0000 0001B |
RCSU-006 |
||
|
– S-RNTI |
0000 0000 0000 0000 0001B |
RCSU-007 |
||
|
New C-RNTI |
Not Present |
RCSU-008 |
||
|
New H-RNTI |
Not Present |
Rel-6 |
RCSU-009 |
|
|
New Primary E-RNTI |
Not Present |
Rel-6 |
RCSU-010 |
|
|
New Secondary E-RNTI |
Not Present |
Rel-6 |
RCSU-011 |
|
|
RRC State Indicator |
CELL_DCH |
RCSU-012 |
||
|
UTRAN DRX cycle length coefficient |
9 |
RCSU-013 |
||
|
Capability update requirement |
RCSU-014 |
|||
|
– UE radio access FDD capability update requirement |
TRUE |
RCSU-015 |
||
|
– UE radio access TDD capability update requirement |
FALSE |
RCSU-016 |
||
|
– UE radio access 3.84 Mcps TDD capability update requirement |
FALSE |
Rel-4 |
RCSU-017 |
|
|
– UE radio access 1.28 Mcps TDD capability update requirement |
FALSE |
Rel-4 |
RCSU-018 |
|
|
– System specific capability update requirement list |
1 entry (for Rel-7 and earlier) 2 entry (for Rel-8 and later) |
RCSU-019 |
||
|
– System specific capability update requirement |
GSM |
RCSU-019a |
||
|
– System specific capability update requirement |
E-UTRA |
Rel-8 |
RCSU-019b |
|
|
CHOICE specification mode |
Complete specification |
Rel-5 |
RCSU-020 |
|
|
– Complete specification |
Rel-5 |
RCSU-021 |
||
|
– Signalling RB information to setup list |
4 SRBs |
RCSU-022 |
||
|
– Signalling RB information to setup |
(UM DCCH for RRC) |
RCSU-023 |
||
|
– RB identity |
Not Present |
RCSU-024 |
||
|
– CHOICE RLC info type |
RLC info |
RCSU-025 |
||
|
– CHOICE Uplink RLC mode |
UM RLC |
RCSU-026 |
||
|
– Transmission RLC discard |
Not Present |
RCSU-027 |
||
|
– CHOICE Downlink RLC mode |
UM RLC |
RCSU-028 |
||
|
– DL UM RLC LI size |
7 bit |
Rel-6 |
RCSU-029 |
|
|
– One sided RLC re-establishment |
FALSE |
Rel-6 |
RCSU-030 |
|
|
– RB mapping info |
RCSU-031 |
|||
|
– Information for each multiplexing option |
2 RBMuxOptions |
RCSU-032 |
||
|
– RLC logical channel mapping indicator |
Not Present |
RCSU-033 |
||
|
– Number of RLC logical channels |
1 |
RCSU-034 |
||
|
– Uplink transport channel type |
DCH |
RCSU-035 |
||
|
– UL Transport channel identity |
5 |
RCSU-036 |
||
|
– Logical channel identity |
1 |
RCSU-037 |
||
|
– CHOICE RLC size list |
Configured |
RCSU-038 |
||
|
– MAC logical channel priority |
1 |
RCSU-039 |
||
|
– Downlink RLC logical channel info |
RCSU-040 |
|||
|
– Number of RLC logical channels |
1 |
RCSU-041 |
||
|
– Downlink transport channel type |
DCH |
RCSU-042 |
||
|
– DL DCH Transport channel identity |
10 |
RCSU-043 |
||
|
– DL DSCH Transport channel identity |
Not Present |
RCSU-044 |
||
|
– Logical channel identity |
1 |
RCSU-045 |
||
|
– RLC logical channel mapping indicator |
Not Present |
RCSU-046 |
||
|
– Number of RLC logical channels |
1 |
RCSU-047 |
||
|
– Uplink transport channel type |
RACH |
RCSU-048 |
||
|
– UL Transport channel identity |
Not Present |
RCSU-049 |
||
|
– Logical channel identity |
1 |
RCSU-050 |
||
|
– CHOICE RLC size list |
Explicit List |
RCSU-051 |
||
|
– RLC size index |
Reference to clause 6 Parameter Set |
RCSU-052 |
||
|
– MAC logical channel priority |
1 |
RCSU-053 |
||
|
– Downlink RLC logical channel info |
RCSU-054 |
|||
|
– Number of RLC logical channels |
1 |
RCSU-055 |
||
|
– Downlink transport channel type |
FACH |
RCSU-056 |
||
|
– DL DCH Transport channel identity |
Not Present |
RCSU-057 |
||
|
– DL DSCH Transport channel identity |
Not Present |
RCSU-058 |
||
|
– Logical channel identity |
1 |
RCSU-059 |
||
|
– Signalling RB information to setup |
(AM DCCH for RRC) |
RCSU-060 |
||
|
– RB identity |
Not Present |
RCSU-061 |
||
|
– CHOICE RLC info type |
RCSU-062 |
|||
|
– RLC info |
RCSU-063 |
|||
|
– CHOICE Uplink RLC mode |
AM RLC |
RCSU-064 |
||
|
– Transmission RLC discard |
RCSU-065 |
|||
|
– SDU discard mode |
No Discard |
RCSU-066 |
||
|
– MAX_DAT |
15 |
RCSU-067 |
||
|
– Transmission window size |
128 |
RCSU-068 |
||
|
– Timer_RST |
500 |
RCSU-069 |
||
|
– Max_RST |
1 |
RCSU-070 |
||
|
– Polling info |
RCSU-071 |
|||
|
– Timer_poll_prohibit |
200 |
RCSU-072 |
||
|
– Timer_poll |
200 |
RCSU-073 |
||
|
– Poll_PDU |
Not Present |
RCSU-074 |
||
|
– Poll_SDU |
1 |
RCSU-075 |
||
|
– Last transmission PDU poll |
TRUE |
RCSU-076 |
||
|
– Last retransmission PDU poll |
TRUE |
RCSU-077 |
||
|
– Poll_Windows |
99 |
RCSU-078 |
||
|
– Timer_poll_periodic |
Not Present |
RCSU-079 |
||
|
– CHOICE Downlink RLC mode |
AM RLC |
RCSU-080 |
||
|
– DL RLC PDU size |
96 bits |
Rel-6 |
RCSU-081 |
|
|
– DL RLC PDU size |
A1 |
144 bits |
Rel-6 |
RCSU-082 |
|
– In-sequence delivery |
TRUE |
RCSU-083 |
||
|
– Receiving window size |
128 |
RCSU-084 |
||
|
– Downlink RLC status info |
RCSU-085 |
|||
|
– Timer_status_prohibit |
200 |
RCSU-086 |
||
|
– Timer_EPC |
Not Present |
RCSU-087 |
||
|
– Missing PDU indicator |
TRUE |
RCSU-088 |
||
|
– Timer_STATUS_periodic |
Not Present |
RCSU-089 |
||
|
– RB mapping info |
RCSU-090 |
|||
|
– Information for each multiplexing option |
2 RBMuxOptions |
RCSU-091 |
||
|
– RLC logical channel mapping indicator |
Not Present |
RCSU-092 |
||
|
– Number of RLC logical channels |
1 |
RCSU-093 |
||
|
– Uplink transport channel type |
DCH |
RCSU-094 |
||
|
– UL Transport channel identity |
5 |
RCSU-095 |
||
|
– Logical channel identity |
2 |
RCSU-096 |
||
|
– CHOICE RLC size list |
Configured |
RCSU-097 |
||
|
– MAC logical channel priority |
2 |
RCSU-098 |
||
|
– Downlink RLC logical channel info |
RCSU-099 |
|||
|
– Number of RLC logical channels |
1 |
RCSU-100 |
||
|
– Downlink transport channel type |
DCH |
RCSU-101 |
||
|
– DL DCH Transport channel identity |
10 |
RCSU-102 |
||
|
– DL DSCH Transport channel identity |
Not Present |
RCSU-103 |
||
|
– Logical channel identity |
2 |
RCSU-104 |
||
|
– RLC logical channel mapping indicator |
Not Present |
RCSU-105 |
||
|
– Number of RLC logical channels |
1 |
RCSU-106 |
||
|
– Uplink transport channel type |
RACH |
RCSU-107 |
||
|
– UL Transport channel identity |
Not Present |
RCSU-108 |
||
|
– Logical channel identity |
2 |
RCSU-109 |
||
|
– CHOICE RLC size list |
Explicit List |
RCSU-110 |
||
|
– RLC size index |
Reference to clause 6 Parameter Set |
RCSU-111 |
||
|
– MAC logical channel priority |
2 |
RCSU-112 |
||
|
– Downlink RLC logical channel info |
RCSU-113 |
|||
|
– Number of RLC logical channels |
1 |
RCSU-114 |
||
|
– Downlink transport channel type |
FACH |
RCSU-115 |
||
|
– DL DCH Transport channel identity |
Not Present |
RCSU-116 |
||
|
– DL DSCH Transport channel identity |
Not Present |
RCSU-117 |
||
|
– Logical channel identity |
2 |
RCSU-118 |
||
|
– Signalling RB information to setup |
(AM DCCH for NAS_DT High priority) |
RCSU-119 |
||
|
– RB identity |
Not Present |
RCSU-120 |
||
|
– CHOICE RLC info type |
RCSU-121 |
|||
|
– RLC info |
RCSU-122 |
|||
|
– CHOICE Uplink RLC mode |
AM RLC |
RCSU-123 |
||
|
– Transmission RLC discard |
RCSU-124 |
|||
|
– SDU discard mode |
No Discard |
RCSU-125 |
||
|
– MAX_DAT |
15 |
RCSU-126 |
||
|
– Transmission window size |
128 |
RCSU-127 |
||
|
– Timer_RST |
500 |
RCSU-128 |
||
|
– Max_RST |
1 |
RCSU-129 |
||
|
– Polling info |
RCSU-130 |
|||
|
– Timer_poll_prohibit |
200 |
RCSU-131 |
||
|
– Timer_poll |
200 |
RCSU-132 |
||
|
– Poll_PDU |
Not Present |
RCSU-133 |
||
|
– Poll_SDU |
1 |
RCSU-134 |
||
|
– Last transmission PDU poll |
TRUE |
RCSU-135 |
||
|
– Last retransmission PDU poll |
TRUE |
RCSU-136 |
||
|
– Poll_Windows |
99 |
RCSU-137 |
||
|
– Timer_poll_periodic |
Not Present |
RCSU-138 |
||
|
– CHOICE Downlink RLC mode |
AM RLC |
RCSU-139 |
||
|
– DL RLC PDU size |
96 bits |
Rel-6 |
RCSU-140 |
|
|
– DL RLC PDU size |
A1 |
144 bits |
Rel-6 |
RCSU-141 |
|
– In-sequence delivery |
TRUE |
RCSU-142 |
||
|
– Receiving window size |
128 |
RCSU-143 |
||
|
– Downlink RLC status info |
RCSU-144 |
|||
|
– Timer_status_prohibit |
200 |
RCSU-145 |
||
|
– Timer_EPC |
Not Present |
RCSU-146 |
||
|
– Missing PDU indicator |
TRUE |
RCSU-147 |
||
|
– Timer_STATUS_periodic |
Not Present |
RCSU-148 |
||
|
– RB mapping info |
RCSU-149 |
|||
|
– Information for each multiplexing option |
2 RBMuxOptions |
RCSU-150 |
||
|
– RLC logical channel mapping indicator |
Not Present |
RCSU-151 |
||
|
– Number of RLC logical channels |
1 |
RCSU-152 |
||
|
– Uplink transport channel type |
DCH |
RCSU-153 |
||
|
-UL Transport channel identity |
5 |
RCSU-154 |
||
|
– Logical channel identity |
3 |
RCSU-155 |
||
|
– CHOICE RLC size list |
Configured |
RCSU-156 |
||
|
– MAC logical channel priority |
3 |
RCSU-157 |
||
|
– Downlink RLC logical channel info |
RCSU-158 |
|||
|
– Number of RLC logical channels |
1 |
RCSU-159 |
||
|
– Downlink transport channel type |
DCH |
RCSU-160 |
||
|
– DL DCH Transport channel identity |
10 |
RCSU-161 |
||
|
– DL DSCH Transport channel identity |
Not Present |
RCSU-162 |
||
|
– Logical channel identity |
3 |
RCSU-163 |
||
|
– RLC logical channel mapping indicator |
Not Present |
RCSU-164 |
||
|
– Number of RLC logical channels |
1 |
RCSU-165 |
||
|
– Uplink transport channel type |
RACH |
RCSU-166 |
||
|
– UL Transport channel identity |
Not Present |
RCSU-167 |
||
|
– Logical channel identity |
3 |
RCSU-168 |
||
|
– CHOICE RLC size list |
Explicit List |
RCSU-169 |
||
|
– RLC size index |
Reference to clause 6 Parameter Set |
RCSU-170 |
||
|
– MAC logical channel priority |
3 |
RCSU-171 |
||
|
– Downlink RLC logical channel info |
RCSU-172 |
|||
|
– Number of RLC logical channels |
1 |
RCSU-173 |
||
|
– Downlink transport channel type |
FACH |
RCSU-174 |
||
|
– DL DCH Transport channel identity |
Not Present |
RCSU-175 |
||
|
– DL DSCH Transport channel identity |
Not Present |
RCSU-176 |
||
|
– Logical channel identity |
3 |
RCSU-177 |
||
|
– Signalling RB information to setup |
(AM DCCH for NAS_DT Low priority) |
RCSU-178 |
||
|
– RB identity |
Not Present |
RCSU-179 |
||
|
– CHOICE RLC info type |
RCSU-180 |
|||
|
– RLC info |
RCSU-181 |
|||
|
– CHOICE Uplink RLC mode |
AM RLC |
RCSU-182 |
||
|
– Transmission RLC discard |
RCSU-183 |
|||
|
– SDU discard mode |
No Discard |
RCSU-184 |
||
|
– MAX_DAT |
15 |
RCSU-185 |
||
|
– Transmission window size |
128 |
RCSU-186 |
||
|
– Timer_RST |
500 |
RCSU-187 |
||
|
– Max_RST |
1 |
RCSU-188 |
||
|
– Polling info |
RCSU-189 |
|||
|
– Timer_poll_prohibit |
200 |
RCSU-190 |
||
|
– Timer_poll |
200 |
RCSU-191 |
||
|
– Poll_PDU |
Not Present |
RCSU-192 |
||
|
– Poll_SDU |
1 |
RCSU-193 |
||
|
– Last transmission PDU poll |
TRUE |
RCSU-194 |
||
|
– Last retransmission PDU poll |
TRUE |
RCSU-195 |
||
|
– Poll_Windows |
99 |
RCSU-196 |
||
|
– Timer_poll_periodic |
Not Present |
RCSU-197 |
||
|
– CHOICE Downlink RLC mode |
AM RLC |
RCSU-198 |
||
|
– DL RLC PDU size |
96 bits |
Rel-6 |
RCSU-199 |
|
|
– DL RLC PDU size |
A1 |
144 bits |
Rel-6 |
RCSU-200 |
|
– In-sequence delivery |
TRUE |
RCSU-201 |
||
|
– Receiving window size |
128 |
RCSU-202 |
||
|
– Downlink RLC status info |
RCSU-203 |
|||
|
– Timer_status_prohibit |
200 |
RCSU-204 |
||
|
– Timer_EPC |
Not Present |
RCSU-205 |
||
|
– Missing PDU indicator |
TRUE |
RCSU-206 |
||
|
– Timer_STATUS_periodic |
Not Present |
RCSU-207 |
||
|
– RB mapping info |
RCSU-208 |
|||
|
– Information for each multiplexing option |
2 RBMuxOptions |
RCSU-209 |
||
|
– RLC logical channel mapping indicator |
Not Present |
RCSU-210 |
||
|
– Number of RLC logical channels |
1 |
RCSU-211 |
||
|
– Uplink transport channel type |
DCH |
RCSU-212 |
||
|
– UL Transport channel identity |
5 |
RCSU-213 |
||
|
– Logical channel identity |
4 |
RCSU-214 |
||
|
– CHOICE RLC size list |
Configured |
RCSU-215 |
||
|
– MAC logical channel priority |
4 |
RCSU-216 |
||
|
– Downlink RLC logical channel info |
RCSU-217 |
|||
|
– Number of RLC logical channels |
1 |
RCSU-218 |
||
|
– Downlink transport channel type |
DCH |
RCSU-219 |
||
|
– DL DCH Transport channel identity |
10 |
RCSU-220 |
||
|
– DL DSCH Transport channel identity |
Not Present |
RCSU-221 |
||
|
– Logical channel identity |
4 |
RCSU-222 |
||
|
– RLC logical channel mapping indicator |
Not Present |
RCSU-223 |
||
|
– Number of RLC logical channels |
1 |
RCSU-224 |
||
|
– Uplink transport channel type |
RACH |
RCSU-225 |
||
|
– UL Transport channel identity |
Not Present |
RCSU-226 |
||
|
– Logical channel identity |
4 |
RCSU-227 |
||
|
– CHOICE RLC size list |
Explicit List |
RCSU-228 |
||
|
– RLC size index |
Reference to clause 6 Parameter Set |
RCSU-229 |
||
|
– MAC logical channel priority |
4 |
RCSU-230 |
||
|
– Downlink RLC logical channel info |
RCSU-231 |
|||
|
– Number of RLC logical channels |
1 |
RCSU-232 |
||
|
– Downlink transport channel type |
FACH |
RCSU-233 |
||
|
– DL DCH Transport channel identity |
Not Present |
RCSU-234 |
||
|
– DL DSCH Transport channel identity |
Not Present |
RCSU-235 |
||
|
– Logical channel identity |
4 |
RCSU-236 |
||
|
UL Transport channel information for all transport channels |
RCSU-237 |
|||
|
– PRACH TFCS |
Not Present |
RCSU-238 |
||
|
– CHOICE Mode |
FDD |
RCSU-239 |
||
|
– TFC subset |
Not Present |
RCSU-240 |
||
|
– UL DCH TFCS |
RCSU-241 |
|||
|
– CHOICE TFCI signalling |
Normal |
RCSU-242 |
||
|
– TFCI Field 1 information |
RCSU-243 |
|||
|
– CHOICE TFCS representation |
Complete reconfiguration |
RCSU-244 |
||
|
– TFCS complete reconfiguration information |
RCSU-245 |
|||
|
– CHOICE CTFC Size |
2 bit CTFC |
RCSU-246 |
||
|
– CTFC information |
2 TFCs |
RCSU-247 |
||
|
– 2bit CTFC |
0 |
RCSU-248 |
||
|
– Power offset Information |
RCSU-249 |
|||
|
– CHOICE Gain Factors |
computedGainFactors |
RCSU-250 |
||
|
– Reference TFC ID |
0 |
RCSU-251 |
||
|
– CHOICE mode |
FDD |
RCSU-252 |
||
|
– Power offset Pp-m |
Not Present |
RCSU-253 |
||
|
– 2bit CTFC |
1 |
RCSU-254 |
||
|
– Power offset Information |
RCSU-255 |
|||
|
– CHOICE Gain Factors |
signalledGainFactors |
RCSU-256 |
||
|
– CHOICE mode |
FDD |
RCSU-257 |
||
|
– Gain factor ßc |
15 |
RCSU-258 |
||
|
– Gain factor ßd |
15 |
RCSU-259 |
||
|
– Reference TFC ID |
0 |
RCSU-260 |
||
|
– CHOICE mode |
FDD |
RCSU-261 |
||
|
– Power offset Pp-m |
Not Present |
RCSU-262 |
||
|
Added or Reconfigured UL TrCH information list |
1 |
RCSU-263 |
||
|
– Added or Reconfigured UL TrCH information |
RCSU-264 |
|||
|
– Uplink transport channel type |
DCH |
RCSU-265 |
||
|
– UL Transport channel identity |
5 |
RCSU-266 |
||
|
– TFS |
RCSU-267 |
|||
|
– CHOICE Transport channel type |
Dedicated transport channels |
RCSU-268 |
||
|
– Dynamic Transport Format Information |
RCSU-269 |
|||
|
– RLC size |
96 bits |
RCSU-270 |
||
|
– RLC size |
A1 |
144 bits |
RCSU-271 |
|
|
– Number of TBs and TTI List |
2 |
RCSU-272 |
||
|
– Transmission Time Interval |
Not Present |
RCSU-273 |
||
|
– Number of Transport blocks |
0 |
RCSU-274 |
||
|
– Transmission Time Interval |
Not Present |
RCSU-275 |
||
|
– Number of Transport blocks |
1 |
RCSU-276 |
||
|
– CHOICE Logical channel List |
ALL |
RCSU-277 |
||
|
– Semi-static Transport Format Information |
RCSU-278 |
|||
|
– Transmission time interval |
40 |
RCSU-279 |
||
|
– Type of channel coding |
Convolutional |
RCSU-280 |
||
|
– Coding Rate |
1/3 |
RCSU-281 |
||
|
– Rate matching attribute |
256 |
RCSU-282 |
||
|
– CRC size |
12 |
RCSU-283 |
||
|
– CRC size |
A1 |
16 |
RCSU-284 |
|
|
DL Transport channel information common for all transport channel |
RCSU-285 |
|||
|
– SCCPCH TFCS |
Not Present |
RCSU-286 |
||
|
– CHOICE mode |
FDD |
RCSU-287 |
||
|
– CHOICE DL parameters |
Same as UL |
RCSU-288 |
||
|
Added or Reconfigured DL TrCH information list |
1 |
RCSU-289 |
||
|
– Added or Reconfigured DL TrCH information |
RCSU-290 |
|||
|
– Downlink transport channel type |
DCH |
RCSU-291 |
||
|
– DL Transport channel identity |
10 |
RCSU-292 |
||
|
– CHOICE DL parameters |
SameAasUL |
RCSU-293 |
||
|
– Uplink transport channel type |
DCH |
RCSU-294 |
||
|
– UL TrCH Identity |
5 |
RCSU-295 |
||
|
– DCH quality target |
RCSU-296 |
|||
|
– BLER Quality value |
-20 (-2.0) |
RCSU-297 |
||
|
Frequency info |
Not Present |
RCSU-298 |
||
|
Maximum allowed UL TX power |
Not Present |
RCSU-299 |
||
|
CHOICE channel requirement |
Uplink DPCH info |
Rel-5 and earlier |
RCSU-300 |
|
|
Uplink DPCH info |
Rel-6 |
RCSU-301 |
||
|
– Uplink DPCH power control info |
RCSU-302 |
|||
|
– DPCCH power offset |
-40 (-80dB) |
RCSU-303 |
||
|
– PC Preamble |
1 frame |
RCSU-304 |
||
|
– SRB delay |
7 frames |
RCSU-305 |
||
|
– Power Control Algorithm |
Algorithm1 |
RCSU-306 |
||
|
– TPC step size |
0 (1dB) |
RCSU-307 |
||
|
– ACK |
Not Present |
Rel-5 |
RCSU-308 |
|
|
– NACK |
Not Present |
Rel-5 |
RCSU-309 |
|
|
– Ack-Nack repetition factor |
Not Present |
Rel-5 |
RCSU-310 |
|
|
– HARQ_preamble_mode |
0 |
Rel-6 |
RCSU-311 |
|
|
– CHOICE mode |
FDD |
RCSU-312 |
||
|
– Scrambling code type |
Long |
RCSU-313 |
||
|
– Scrambling code number |
0 (0 to 16777215) |
RCSU-314 |
||
|
– Number of DPDCH |
Not Present (1) |
RCSU-315 |
||
|
– Spreading factor |
256 |
RCSU-316 |
||
|
– TFCI existence |
TRUE |
RCSU-317 |
||
|
– Number of FBI bit |
Not Present(0) |
RCSU-318 |
||
|
– Puncturing Limit |
1 |
RCSU-319 |
||
|
E-DCH Info |
Not Present |
Rel-6 |
RCSU-320 |
|
|
Downlink HS-PDSCH Information |
Not Present |
Rel-6 |
RCSU-321 |
|
|
Downlink information common for all radio links |
RCSU-322 |
|||
|
– Downlink DPCH info common for all RL |
RCSU-323 |
|||
|
– Timing Indication |
Initialize |
RCSU-324 |
||
|
– CFN-targetSFN frame offset |
Not Present |
RCSU-325 |
||
|
– Downlink DPCH power control information |
RCSU-326 |
|||
|
– CHOICE mode |
FDD |
RCSU-327 |
||
|
– DPC mode |
0 (single) |
RCSU-328 |
||
|
– CHOICE mode |
FDD |
RCSU-329 |
||
|
– Power offset P Pilot-DPDCH |
0 |
RCSU-330 |
||
|
– DL rate matching restriction information |
Not Present |
RCSU-331 |
||
|
– Spreading factor |
256 |
RCSU-332 |
||
|
– Fixed or Flexible Position |
Fixed |
RCSU-333 |
||
|
– TFCI existence |
FALSE |
RCSU-334 |
||
|
– CHOICE SF |
RCSU-335 |
|||
|
– Number of bits for Pilot bits |
8 |
RCSU-336 |
||
|
– DPCH compressed mode info |
Not Present |
RCSU-337 |
||
|
– TX Diversity mode |
None |
RCSU-338 |
||
|
– SSDT information |
Not Present |
R99 and Rel-4 only |
RCSU-339 |
|
|
– Default DPCH Offset Value |
Arbitrary set to value 0..306688 by step of 512 |
RCSU-340 |
||
|
Downlink information for per radio links list |
RCSU-341 |
|||
|
-Downlink information for each radio links |
RCSU-342 |
|||
|
– CHOICE mode |
FDD |
RCSU-343 |
||
|
– Primary CPICH info |
RCSU-344 |
|||
|
– Primary scrambling code |
Reference to clause 6.1 "Default settings (FDD)" |
RCSU-345 |
||
|
– PDSCH with SHO DCH info |
Not Present |
R99 and Rel-4 only |
RCSU-346 |
|
|
– PDSCH code mapping |
Not Present |
R99 and Rel-4 only |
RCSU-347 |
|
|
– Serving HS-DSCH radio link indicator |
FALSE |
Rel-6 |
RCSU-348 |
|
|
– Serving E-DCH radio link indicator |
FALSE |
Rel-6 |
RCSU-349 |
|
|
– Downlink DPCH info for each RL |
RCSU-350 |
|||
|
– CHOICE mode |
FDD |
RCSU-351 |
||
|
– Primary CPICH usage for channel estimation |
Primary CPICH may be used |
RCSU-352 |
||
|
– DPCH frame offset |
Set to value : Default DPCH Offset Value mod 38 400 |
RCSU-353 |
||
|
– Secondary CPICH info |
Not Present |
RCSU-354 |
||
|
– DL channelisation code |
RCSU-355 |
|||
|
– Secondary scrambling code |
Not Present |
RCSU-356 |
||
|
– Spreading factor |
256 |
RCSU-357 |
||
|
– Code number |
192 |
RCSU-358 |
||
|
– Scrambling code change |
Not Present |
RCSU-359 |
||
|
– TPC combination index |
0 |
RCSU-360 |
||
|
– SSDT Cell Identity |
Not Present |
R99 and Rel-4 only |
RCSU-361 |
|
|
– Closed loop timing adjustment mode |
Not Present |
RCSU-362 |
||
|
– E-AGCH Info |
Not Present |
Rel-6 |
RCSU-363 |
|
|
– E-HICH Information |
Not Present |
Rel-6 |
RCSU-364 |
|
|
– E-RGCH Information |
Not Present |
Rel-6 |
RCSU-365 |
|
|
– SCCPCH information for FACH |
Not Present |
R99 and Rel-4 only |
RCSU-366 |
|
Condition |
Explanation |
|
A1 |
UE supporting 64kbps(Chanel2) |
Contents of SECURITY MODE COMMAND message: AM
|
Information Element |
Condition |
Value/remark |
|
Message Type |
A1, A2 |
|
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
|
|
Integrity check info |
||
|
– Message authentication code |
Set to an arbitrarily selected 32-bits integer. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
|
|
– RRC Message Sequence Number |
Set to an arbitrarily selected integer between 0 and 15 |
|
|
Security capability |
||
|
– Ciphering algorithm capability |
||
|
– UEA0 |
If the UE has indicated support for ciphering algorithm UEA0 in the IE "security capability" in the RRC CONNECTION SETUP COMPLETE message, this IE is set to TRUE. |
|
|
– UEA1 |
If the UE has indicated support for ciphering algorithm UEA1 in the IE "security capability" in the RRC CONNECTION SETUP COMPLETE message, this IE is set to TRUE. |
|
|
– Spare |
Spare 2-15 = FALSE |
|
|
– Integrity protection algorithm capability |
0000000000000010B (UIA1) |
|
|
– UIA1 |
TRUE |
|
|
– Spare |
Spare 0 and Spare 2-15 = FALSE |
|
|
Ciphering mode info |
This presence of this IE is dependent on IXIT statements in TS 34.123-2. If ciphering is indicated to be active, this IE present with the values of the sub IEs as stated below. Else, this IE is omitted. |
|
|
– Ciphering mode command |
Start/restart |
|
|
– Ciphering algorithm |
UEA0 or UEA1. The indicated algorithm must be one of the algorithms supported by the UE as indicated in the IE "security capability" in the RRC CONNECTION SETUP COMPLETE message. |
|
|
– Ciphering activation time for DPCH |
Not Present |
|
|
– Radio bearer downlink ciphering activation time info |
||
|
– Radio bearer activation time |
||
|
– RB identity |
1 |
|
|
– RLC sequence number |
Current RLC SN |
|
|
– RB identity |
2 |
|
|
– RLC sequence number |
Current RLC SN+3(or Calculated Value) |
|
|
– RB identity |
3 |
|
|
– RLC sequence number |
Current RLC SN |
|
|
– RB identity |
4 |
|
|
– RLC sequence number |
Current RLC SN |
|
|
Integrity protection mode info |
||
|
– Integrity protection mode command |
Start |
|
|
– Downlink integrity protection activation info |
Not Present |
|
|
– Integrity protection algorithm |
UIA1 |
|
|
– Integrity protection initialisation number |
SS selects an arbitrary 32 bits number for FRESH. The first/ leftmost bit of the bit string contains the most significant bit of the FRESH.A1 |
|
|
CN domain identity |
CS or PS |
|
|
UE system specific security capability |
A1 |
Not Present |
|
UE system specific security capability |
A2 |
|
|
– Inter-RAT UE security capability |
||
|
– CHOICE system |
GSM |
|
|
– GSM security capability |
The indicated algorithms must be the same as the algorithms supported by the UE as indicated in the IE " UE system specific capability " in the RRC CONNECTION SETUP COMPLETE message. |
|
Condition |
Explanation |
|
A1 |
UE not supporting GSM |
|
A2 |