9.1.1 Default RRC Message Contents (FDD)
34.1083GPPCommon test environments for User Equipment (UE)Conformance testingRelease 15TS
This clause contains the default values of common messages, which unless indicated otherwise in specific clauses of 3GPP TS 34.123-1 [1], shall be transmitted and checked by the system simulator.
In this clause, decimal values are normally used. However, sometimes a hexadecimal value, indicated by an "H", or a binary value, indicated by a "B" is used.
The necessary L3 messages are listed in alphabetic order, with the exception of the SYSTEM INFORMATION messages, where it is the information elements which are listed in alphabetic order (this is because some information elements occur in several SYSTEM INFORMATION types).
Default SYSTEM INFORMATION:
NOTE: SYSTEM INFORMATION BLOCK TYPE 1 (except for PLMN type "GSM-MAP"), SYSTEM INFORMATION BLOCK TYPE 8, SYSTEM INFORMATION BLOCK TYPE 9, SYSTEM INFORMATION BLOCK TYPE 10, SYSTEM INFORMATION BLOCK TYPE 14, SYSTEM INFORMATION BLOCK TYPE 15 and SYSTEM INFORMATION BLOCK TYPE 16 messages are not used.
Contents of ACTIVE SET UPDATE message: AM
|
Information Element |
Value/remark |
Version |
|---|---|---|
|
Message Type |
||
|
RRC transaction identifier |
Arbitrarily selects one integer between 0 to 3 |
|
|
Integrity check info |
||
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
|
|
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
|
|
Activation time |
Now |
|
|
New U-RNTI |
Not Present |
|
|
New H-RNTI |
Not Present |
Rel-6 |
|
New Primary E-RNTI |
Not Present |
Rel-6 |
|
New Secondary E-RNTI |
Not Present |
Rel-6 |
|
CN information info |
Not Present |
|
|
DTX-DRX timing information |
Not Present |
Rel-7 |
|
DTX-DRX Information |
Not Present |
Rel-7 |
|
HS-SCCH less Information |
Not Present |
Rel-7 |
|
MIMO parameters |
Not Present |
Rel-7 |
|
MIMO mode with four transmit antennas parameters |
Not Present |
Rel-11 |
|
DCH Enhancements info FDD |
Not Present |
Rel-12 |
|
Maximum allowed UL TX power |
Not Present – use default value |
|
|
Uplink secondary cell info FDD |
Not Present |
Rel-9 |
|
E-DCH reconfiguration information on secondary UL frequency |
Not Present |
Rel-9 |
|
Uplink CLTD info FDD |
Not Present |
Rel-11 |
|
F-TPICH reconfiguration info |
Not Present |
Rel-11 |
|
Uplink OLTD info FDD |
Not Present |
Rel-11 |
|
Radio link addition information |
Not Present |
|
|
Radio link addition information on secondary UL frequency |
Not Present |
Rel-9 |
|
Serving Cell Change Parameters |
Not present |
Rel-8 |
|
Radio link removal information |
Not Present |
|
|
Radio link removal information on secondary UL frequency |
Not present |
Rel-9 |
|
TX Diversity Mode |
None |
|
|
SSDT information |
Not Present |
R99 and Rel-4 only |
|
DPC Mode |
Not Present |
Rel-5 |
|
Serving HS-DSCH cell information |
Not Present |
Rel-6 |
|
E-DCH reconfiguration information |
Not Present |
Rel-6 |
|
UL 16QAM configuration |
Not Present |
Rel-7 |
|
UL 64QAM configuration |
Not Present |
Rel-11 |
|
Uplink MIMO info FDD |
Not Present |
Rel-11 |
|
E-DCH reconfiguration information same serving cell |
Not Present |
Rel-7 |
|
E-TFC Boost Info |
Not Present |
Rel-7 |
|
E-DPDCH power interpolation |
Not Present |
Rel-7 |
|
Downlink secondary cell info FDD |
Not present |
Rel-8 |
|
Additional downlink secondary cell info list FDD |
Not present |
Rel-10 |
|
Downlink secondary cell info FDD |
Not Present |
Rel-10 |
|
Additional downlink secondary cell info list FDD 2 |
Not present |
Rel-11 |
|
Downlink secondary cell info FDD |
Not Present |
Rel-11 |
Contents of ACTIVE SET UPDATE COMPLETE message: AM
|
Information Element |
Value/remark |
|
Message Type |
|
|
RRC transaction identifier |
Checked to see if it matches the same value used in the corresponding downlink ACTIVE SET UPDATE message |
|
Integrity check info |
|
|
– Message authentication code |
This IE is checked to see if it is present. The value is compared against the XMAC-I value computed by SS. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
|
– RRC Message sequence number |
This IE is checked to see if it is present. The value is used by SS to compute the XMAC-I value. |
Contents of ACTIVE SET UPDATE FAILURE message: AM
|
Information Element |
Value/remark |
|
Message Type |
|
|
RRC transaction identifier |
Checked to see if it matches the same value used in the corresponding downlink ACTIVE SET UPDATE message |
|
Integrity check info |
|
|
– Message authentication code |
This IE is checked to see if it is present. The value is compared against the XMAC-I value computed by SS. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
|
– RRC Message sequence number |
This IE is checked to see if it is present. The value is used by SS to compute the XMAC-I value. |
|
Failure cause |
Refer to test requirement |
Contents of CELL UPDATE message: TM
|
Information Element |
Value/remark |
Version |
|
Message Type |
||
|
U-RNTI |
Checked to see if it is set to the following values |
|
|
– SRNC identity |
0000 0000 0001B |
|
|
– S-RNTI |
0000 0000 0000 0000 0001B |
|
|
RRC transaction identifier |
Checked to see if it is absent |
|
|
Integrity check info |
||
|
– Message authentication code |
This IE is checked to see if it is present. The value is compared against the XMAC-I value computed by SS. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
|
|
– RRC Message sequence number |
This IE is checked to see if it is present. The value is used by SS to compute the XMAC-I value. |
|
|
START List |
Checked to see if the ‘CN domain identity’ and ‘START’ IEs are present for all CN domains supported by the UE . |
|
|
Checked to see if the ‘CN domain identity’ and ‘START’ IEs are present for each CN domain for which RABs are established or is the latest configured CN domain. |
Rel-6 |
|
|
– CN domain identity |
Checked to see if it is one of the supported CN domains |
|
|
– START |
This IE is checked to see if it is present. The first/ leftmost bit of the bit string contains the most significant bit of the START. |
|
|
AM_RLC error indication (RB2, RB3 or RB4) |
Checked to see if it is set to ‘FALSE’ |
|
|
AM_RLC error indication (RB>4) |
Checked to see if it is set to ‘FALSE’ |
|
|
Cell update cause |
See the specific test case |
|
|
Traffic volume indicator |
Checked to see if it is absent |
Rel-6 |
|
Failure cause |
Checked to see if it is absent |
|
|
RB timer indicator |
||
|
– T314 expired |
Checked to see if it is set to ‘FALSE’ |
|
|
– T315 expired |
Checked to see if it is set to ‘FALSE’ |
|
|
Establishment cause |
This IE is checked to see if it is absent |
Rel-5 |
|
CS Call Type |
Not Present |
Rel-7 |
|
HS-PDSCH in CELL_FACH |
Not checked |
Rel-7 |
|
UE Mobility State Indicator |
Not Present |
Rel-7 |
|
Capability change indicator |
Not Present |
Rel-7 |
|
Reconfiguration Status Indicator |
Checked to see if it is absent |
Rel-6 |
|
Measured results on RACH |
Not checked |
|
|
Logged Meas Available |
Not Present |
Rel-10 |
|
ANR Logging Results Available |
Not Present |
Rel-10 |
Contents of CELL UPDATE CONFIRM message: UM
|
Information Element |
Value/remark |
Version |
|---|---|---|
|
Message Type |
||
|
U-RNTI |
If this message is sent on CCCH, use the following values. Else, this IE is absent. |
|
|
– SRNC identity |
0000 0000 0001B |
|
|
– S-RNTI |
0000 0000 0000 0000 0001B |
|
|
RRC transaction identifier |
Selects an arbitrary integer between 0 to 3 |
|
|
Integrity check info |
||
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
|
|
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
|
|
Integrity protection mode info |
Not Present |
|
|
Ciphering mode info |
Not Present |
|
|
Activation time |
Not Present – use default value |
|
|
New U-RNTI |
Not Present |
|
|
New C-RNTI |
Not Present |
|
|
New DSCH-RNTI |
Not Present |
R99 and Rel-4 only |
|
New H-RNTI |
Not Present |
Rel-5 |
|
New Primary E-RNTI |
Not present |
Rel-6 |
|
New Secondary E-RNTI |
Not present |
Rel-6 |
|
RRC State indicator |
CELL_FACH |
|
|
UTRAN DRX cycle length coefficient |
Not Present |
|
|
RLC re-establish indicator (RB2, RB3 and RB4) |
FALSE |
|
|
RLC re-establish indicator (RB5 and upwards) |
FALSE |
|
|
CN information info |
Not Present |
|
|
URA identity |
Not Present |
|
|
RNC support for change of UE capability |
Not Present |
Rel-7 |
|
RB information to release list |
Not Present |
|
|
RB information to reconfigure list |
Not Present |
|
|
RB information to be affected list |
Not Present |
|
|
Downlink counter synchronization info |
Not Present |
|
|
PDCP ROHC target mode |
Not Present |
Rel-5 |
|
UL Transport channel information common for all transport channels |
Not Present |
|
|
Deleted TrCH information list |
Not Present |
|
|
Added or Reconfigured TrCH information list |
Not Present |
|
|
CHOICE Mode |
FDD |
|
|
– CPCH set ID |
Not Present |
R99 and Rel-4 only |
|
– Added or Reconfigured TrCH |
Not Present |
R99 and Rel-4 only |
|
DL Transport channel information common for all transport channels |
Not Present |
|
|
Deleted TrCH information list |
Not Present |
|
|
Added or Reconfigured TrCH information list |
Not Present |
|
|
Frequency info |
Not Present |
|
|
DTX-DRX timing information |
Not Present |
Rel-7 |
|
DTX-DRX Information |
Not Present |
Rel-7 |
|
HS-SCCH less Information |
Not Present |
Rel-7 |
|
MIMO parameters |
Not Present |
Rel-7 |
|
MIMO mode with four transmit antennas parameters |
Not Present |
Rel-11 |
|
DCH Enhancements info FDD |
Not Present |
Rel-12 |
|
Maximum allowed UL TX power |
Not Present |
|
|
CHOICE channel requirement |
Not Present |
|
|
E-DCH Info |
Not Present |
Rel-6 |
|
CHOICE mode |
FDD |
R99 and Rel-4 only |
|
– Downlink PDSCH information |
Not Present |
R99 and Rel-4 only |
|
Uplink secondary cell info FDD |
Not Present |
Rel-9 |
|
Uplink CLTD info FDD |
Not Present |
Rel-11 |
|
Uplink OLTD info FDD |
Not Present |
Rel-11 |
|
Downlink HS-PDSCH Information |
Not Present |
Rel-5 |
|
Downlink information common for all radio links |
Not Present |
|
|
Downlink information per radio link list |
Not Present |
|
|
Downlink information for each radio link |
Not Present |
|
|
Downlink secondary cell info FDD |
Not Present |
Rel-8 |
|
Additional downlink secondary cell info list FDD |
Not present |
Rel-10 |
|
Downlink secondary cell info FDD |
Not Present |
Rel-10 |
|
Additional downlink secondary cell info list FDD 2 |
Not present |
Rel-11 |
|
Downlink secondary cell info FDD |
Not Present |
Rel-11 |
|
Common E-RGCH info FDD |
Not Present |
Rel-11 |
|
MBMS PL Service Restriction Information |
Not Present |
Rel-6 |
Contents of DOWNLINK DIRECT TRANSFER message: AM
|
Information Element |
Value/remark |
|
Message Type |
|
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
|
Integrity check info |
|
|
– Message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
|
– RRC Message sequence number |
SS provides the value of this IE, from its internal counter. |
|
CN domain identity |
CS domain or PS domain |
|
NAS message |
See Specific Message Content for each test case |
Contents of HANDOVER FROM UTRAN COMMAND-GSM message: AM
|
Information Element |
Value/remark |
|
Message Type |
|
|
RRC transaction identifier |
Arbitrarily selects one integer between 0 to 3 |
|
Integrity check info |
|
|
– Message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
|
– RRC Message sequence number |
SS provides the value of this IE, from its internal counter. |
|
Activation time |
now |
|
RAB Info |
|
|
– RAB identity |
0000 0001B The first/ leftmost bit of the bit string contains the most significant bit of the RAB identity. |
|
– CN domain identity |
CS domain |
|
– NAS Synchronization Indicator |
Not present |
|
– Re-establishment timer |
Use T314 |
|
Inter-system message |
|
|
– CHOICE System type |
GSM |
|
– Frequency Band |
Set to "GSM/ PCS 1900" if GSM/ PCS 1900 is used in this test. Otherwise set to "GSM/DCS 1800 Band" |
|
– CHOICE GSM message |
Single GSM message |
|
– Single GSM message |
GSM HANDOVER COMMAND formatted and coded according to GSM specifications as BIT STRING (1..512). The first/ leftmost/ most significant bit of the bit string contains bit 8 of the first octet of the GSM message. The contents of the HANDOVER COMMAND is to be defined in the specific test case. |
Contents of HANDOVER FROM UTRAN FAILURE message: AM
|
Information Element |
Value/remark |
|
Message Type |
|
|
RRC transaction identifier |
Checked to see if it matches the same value used in the corresponding downlink HANDOVER FROM UTRAN COMMAND -GSM message |
|
Integrity check info |
|
|
– Message authentication code |
This IE is checked to see if it is present. The value is compared against the XMAC-I value computed by SS. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
|
– RRC Message sequence number |
This IE is checked to see if it is present. The value is used by SS to compute the XMAC-I value. |
|
Inter-RAT handover failure |
|
|
-Inter-RAT handover failure cause |
physical channel failure |
|
Inter-system message |
Not Checked |
Contents of INITIAL DIRECT TRANSFER message: AM
|
Information Element |
Value/remark |
Version |
|
Message Type |
||
|
Integrity check info |
||
|
– Message authentication code |
This IE is checked to see if it is present. The value is compared against the XMAC-I value computed by SS. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
|
|
– RRC Message sequence number |
This IE is checked to see if it is present. The value is used by SS to compute the XMAC-I value. |
|
|
PLMN identity |
This IE is checked to see if it is absent |
Rel-6 |
|
CN domain identity |
Checked to see if set to supported CN domain as specified in the IXIT statements. |
|
|
Intra Domain NAS Node Selector |
||
|
– CHOICE version |
R99 |
|
|
– CHOICE CN type |
GSM-MAP |
|
|
– CHOICE Routing basis |
Local (P)TMSI |
|
|
– Routing parameter |
If the IE "CN domain identity" is equal to "CS domain", this bit string is set to bits b14 through b23 of the TMSI. If the IE "CN domain identity" is equal to "PS domain", this bit string is set to bits b14 through b23 of the P-TMSI. The TMSI/P-TMSI consists of 4 octets (32bits). This can be represented by a string of bits numbered from b0 to b31, with bit b0 being the least significant The "Routing parameter" bit string consists of bits b14 through b23 of the TMSI/ PTMSI. The first/ leftmost/ most significant bit of the bit string contains bit b23 of the TMSI/ PTMSI. |
|
|
– Entered parameter |
Not checked |
|
|
NAS message |
Set according to that indicated in specific message content for each test case |
|
|
START |
This IE is checked to see if it is present. |
|
|
Establishment cause |
This IE is checked to see if it is absent |
Rel-5 |
|
Measured results on RACH |
Not checked |
|
|
MBMS joined information |
This IE is checked to see if it is absent |
Rel-6 |
Contents of LOGGING MEASUREMENT CONFIGURATION message: AM
|
Information Element |
Condition |
Value/remark |
Version |
|---|---|---|---|
|
Message Type |
Rel-10 |
||
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Rel-10 |
|
|
Integrity check info |
Rel-10 |
||
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
||
|
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
||
|
Logged Measurements Configuration Info |
A1, A2 |
Not present |
Rel-10 |
|
Logged ANR configuration Info |
A1, A2 |
Rel-10 |
|
|
– Logging Duration |
1 hour |
||
|
– Intra-UTRA ANR |
|||
|
– CHOICE Absolute Threshold |
A1 |
RSCP for ANR |
|
|
– RSCP |
Not present (default -100 dBm) |
||
|
– CHOICE Absolute Threshold |
A2 |
Ec/N0 for ANR |
|
|
– Ec/N0 |
Not present (default -10 dB) |
||
|
– Logging Relative Threshold |
Not present |
||
|
– Inter-RAT ANR for E-UTRA Indicator |
Not present |
||
|
– Inter-RAT ANR for GSM Indicator |
Not present |
|
Condition |
Explanation |
Version |
|
A1 |
Configuring of IE for ANR over UTRAN testing using RSCP for Absolute Threshold |
Rel-10 |
|
A2 |
Configuring of IE for ANR over UTRAN testing using Ec/N0 for Absolute Threshold |
Rel-10 |
Contents of MBMS ACCESS INFORMATION message: UM
|
Information Element |
Value/remark |
Version |
|---|---|---|
|
Message type |
Rel-6 |
|
|
Service list |
1 entry in the list |
Rel-6 |
|
– MBMS short transmission ID |
Index to the MBMS transmission identity in the previous MBMS MODIFIED SERVICES INFORMATION or MBMS UNMODIFIED SERVICES INFORMATION corresponding to the service for which the current counting procedure applies. |
Rel-6 |
|
– Access probability factor – Idle |
0 (corresponding to the actual probability factor value 1) |
Rel-6 |
|
– Connected mode counting scope |
Rel-6 |
|
|
– URA_PCH |
FALSE |
Rel-6 |
|
– CELL_PCH |
FALSE |
Rel-6 |
|
– CELL_FACH |
FALSE |
Rel-6 |
Contents of MBMS GENERAL INFORMATION message: UM
|
Information Element |
Value/remark |
Version |
|---|---|---|
|
Message type |
Rel-6 |
|
|
MBMS preferred frequency information |
Not Present |
Rel-6 |
|
MBMS timers and counters |
Rel-6 |
|
|
– T318 |
4000 ms |
Rel-6 |
|
MICH configuration information |
Rel-6 |
|
|
– MICH Power offset |
-5dB |
Rel-6 |
|
– CHOICE Mode |
FDD |
Rel-6 |
|
– Channelisation code |
Reference to clause 5.5.1.4 “Downlink physical channels code allocation for MBMS test cases” |
Rel-6 |
|
– Number of NI per frame |
18 |
Rel-6 |
|
– STTD indicator |
FALSE |
Rel-6 |
|
Cell group identity |
‘000000000001’ ( cells with mid range UARFCN ) ‘000000000010’ ( cells with low range UARFCN ) ‘000000000011’ ( cells with high range UARFCN ) |
Rel-6 |
|
Default MSCH configuration information |
Not Present |
Rel-6 |
|
Indicate changes in MBMS Selected Services |
Not Present |
Rel-6 |
Contents of MBMS COMMON P-T-M RB INFORMATION message: UM
|
Information Element |
Value/remark |
Version |
|---|---|---|
|
Message type |
Rel-6 |
|
|
RB information list |
2 entries in the list |
Rel-6 |
|
– RB identity |
14 |
Rel-6 |
|
– PDCP info |
||
|
– Support for lossless SRNS relocation |
Not Present |
|
|
– PDCP PDU header |
absent |
|
|
– Header compression information |
Not Present |
|
|
– RLC info |
||
|
– DL UM RLC LI size |
7 |
|
|
– DL Duplication Avoidance and Reordering info |
Not Present |
|
|
– RB identity |
15 |
Rel-6 |
|
– PDCP info |
||
|
– Support for lossless SRNS relocation |
Not Present |
|
|
– PDCP PDU header |
absent |
|
|
– Header compression information |
Not Present |
|
|
– RLC info |
||
|
– DL UM RLC LI size |
7 |
|
|
– DL Duplication Avoidance and Reordering info |
Not Present |
|
|
TrCh information for each TrCh |
2 entries in the list |
Rel-6 |
|
– Transport channel identity |
17 |
Rel-6 |
|
– TFS |
||
|
– CHOICE Transport channel type |
Common transport channels |
|
|
– Dynamic Transport format information |
||
|
– RLC Size |
Reference to clause 6.10 parameter set |
|
|
– Number of TBs List |
(This IE is repeated for TFI number.) |
|
|
– Transmission Time Interval |
Not Present |
|
|
– Number of Transport blocks |
Reference to clause 6.10 parameter set |
|
|
– CHOICE Logical channel list |
All |
|
|
– Semi-static Transport Format information |
||
|
– Transmission time interval |
Reference to clause 6.10 parameter set |
|
|
– Type of channel coding |
Reference to clause 6.10 parameter set |
|
|
– Coding Rate |
Reference to clause 6.10 parameter set |
|
|
– Rate matching attribute |
Reference to clause 6.10 parameter set |
|
|
– CRC size |
Reference to clause 6.10 parameter set |
|
|
– Transport channel identity |
23 |
Rel-6 |
|
– TFS |
||
|
– CHOICE Transport channel type |
Common transport channels |
|
|
– Dynamic Transport format information |
||
|
– RLC Size |
Reference to clause 6.10 parameter set |
|
|
– Number of TBs List |
(This IE is repeated for TFI number.) |
|
|
– Transmission Time Interval |
Not Present |
|
|
– Number of Transport blocks |
Reference to clause 6.10 parameter set |
|
|
– CHOICE Logical channel list |
All |
|
|
– Semi-static Transport Format information |
||
|
– Transmission time interval |
Reference to clause 6.10 parameter set |
|
|
– Type of channel coding |
Reference to clause 6.10 parameter set |
|
|
– Coding Rate |
Reference to clause 6.10 parameter set |
|
|
– Rate matching attribute |
Reference to clause 6.10 parameter set |
|
|
– CRC size |
Reference to clause 6.10 parameter set |
|
|
TrCh information for each CCTrCh |
2 entries in the list |
Rel-6 |
|
– CCTrCH identity |
1 |
Rel-6 |
|
– TFCS |
||
|
– CHOICE TFCI signalling |
Normal |
|
|
– TFCI Field 1 information |
||
|
– CHOICE TFCS representation |
Complete reconfiguration |
|
|
– TFCS complete reconfiguration information |
||
|
– CHOICE CTFC Size |
Number of bits used must be enough to cover all combinations of CTFC from clause 6.10. |
|
|
– CTFC information |
This IE is repeated for number of CTFCs in clause 6.10 "Parameter Set" |
|
|
– CTFC |
Reference to clause 6.10 "Parameter Set" |
|
|
– Power offset information |
Not Present |
|
|
– CCTrCH identity |
2 |
Rel-6 |
|
– TFCS |
||
|
– CHOICE TFCI signalling |
Normal |
|
|
– TFCI Field 1 information |
||
|
– CHOICE TFCS representation |
Complete reconfiguration |
|
|
– TFCS complete reconfiguration information |
||
|
– CHOICE CTFC Size |
Number of bits used must be enough to cover all combinations of CTFC from clause 6.10. |
|
|
– CTFC information |
This IE is repeated for number of CTFCs in clause 6.10 "Parameter Set" |
|
|
– CTFC |
Reference to clause 6.10 "Parameter Set" |
|
|
– Power offset information |
Not Present |
|
|
PhyCh information |
2 entries in list |
Rel-6 |
|
– PhyCh identity |
13 |
Rel-6 |
|
– Secondary CCPCH info MBMS |
||
|
– CHOICE mode |
FDD |
|
|
– Secondary scrambling code |
Not Present |
|
|
– STTD indicator |
FALSE |
|
|
– Spreading factor |
Reference to clause 6.10 "Parameter Set" |
|
|
– Code number |
Reference to clause 5.5.1.4 “Downlink physical channels code allocation for MBMS test cases” |
|
|
– Timing Offset |
Set to (Cell No. – 21) * 18 for MBMS Cell Nos. 21-28. (actual value = IE value * 256 chips) |
|
|
– PhyCh identity |
17 |
Rel-6 |
|
– Secondary CCPCH info MBMS |
||
|
– CHOICE mode |
FDD |
|
|
– Secondary scrambling code |
Not Present |
|
|
– STTD indicator |
FALSE |
|
|
– Spreading factor |
Reference to clause 6.10 "Parameter Set" |
|
|
– Code number |
Reference to clause 5.5.1.4 “Downlink physical channels code allocation for MBMS test cases” |
|
|
– Timing Offset |
Set to (Cell No. – 21) * 18 for MBMS Cell Nos. 21-28. (actual value = IE value * 256 chips) |
Contents of MBMS CURRENT CELL P-T-M RB INFORMATION message: UM
|
Information Element |
Condition |
Value/remark |
Version |
|---|---|---|---|
|
Message type |
A1, A2, A3 |
Rel-6 |
|
|
S-CCPCH list |
A1 |
Not Present |
Rel-6 |
|
S-CCPCH list |
A2 |
Contains 1 S-CCPCH |
Rel-6 |
|
S-CCPCH list |
A3 |
Contains 2 S-CCPCH |
Rel-6 |
|
– S-CCPCH identity |
A2, A3 |
1 if combining is used in the test (MBMS NEIGHBOURING CELL P-T-M RB INFORMATION is transmitted in the same modification period). Not Present if combining is not used in the test (MBMS NEIGHBOURING CELL P-T-M RB INFORMATION is not transmitted in the same modification period). |
Rel-6 |
|
– Secondary CCPCH info |
13 |
Rel-6 |
|
|
– MBMS Soft Combining Timing Offset |
Not Present |
Rel-6 |
|
|
– TrCh information common for all TrCh |
1 |
Rel-6 |
|
|
– TrCH information list |
Rel-6 |
||
|
– TrCh information |
17 |
Rel-6 |
|
|
– RB information list |
Rel-6 |
||
|
– RB information |
14 |
Rel-6 |
|
|
– MBMS short transmission ID |
Refers to the index of the service in the list of services on the cell which is being provided on this RB |
Rel-6 |
|
|
– MBMS logical channel identity |
1 |
Rel-6 |
|
|
– MSCH configuration information |
Not Present |
Rel-6 |
|
|
– S-CCPCH identity |
A3 |
Not Present |
Rel-6 |
|
– Secondary CCPCH info |
17 |
Rel-6 |
|
|
– MBMS Soft Combining Timing Offset |
Not Present |
Rel-6 |
|
|
– TrCh information common for all TrCh |
2 |
Rel-6 |
|
|
– TrCH information list |
Rel-6 |
||
|
– TrCh information |
23 |
Rel-6 |
|
|
– RB information list |
Rel-6 |
||
|
– RB information |
15 |
Rel-6 |
|
|
– MBMS short transmission ID |
Refers to the index of the service in the list of services on the cell which is being provided on this RB |
Rel-6 |
|
|
– MBMS logical channel identity |
2 |
Rel-6 |
|
|
– MSCH configuration information |
Not Present |
Rel-6 |
|
|
S-CCPCH in SIB type 5 |
A1, A2, A3 |
Not Present |
Rel-6 |
|
Condition |
Explanation |
|
A1 |
No services ongoing or starting |
|
A2 |
1 service ongoing or starting |
|
A3 |
2 services ongoing or starting |
Contents of MBMS MODIFIED SERVICES INFORMATION message: UM
|
Information Element |
Value/remark |
Version |
|---|---|---|
|
Message type |
Rel-6 |
|
|
Modified services list |
1 entry per modified service – maximum 12. If no services are modified in the current modification period this IE is Not Present |
Rel-6 |
|
– MBMS Transmission identity |
Rel-6 |
|
|
– MBMS Service ID |
||
|
– MBMS Service ID |
Set to the value of the service ID being modified (e.g. ‘000001’) |
Rel-6 |
|
– CHOICE PLMN identity |
SameAs-MIB |
Rel-6 |
|
– MBMS Session ID |
‘01’ |
Rel-6 |
|
– MBMS required UE action |
Acquire PTM RB info |
Rel-6 |
|
– MBMS preferred frequency |
Not Present |
Rel-6 |
|
– Continue MCCH reading |
FALSE |
Rel-6 |
|
MBMS re- acquire MCCH |
Not Present |
Rel-6 |
|
MBMS dynamic persistence level |
Not Present |
Rel-6 |
|
End of modified MCCH information |
Not Present |
Rel-6 |
|
MBMS number of neighbour cells |
0 |
Rel-6 |
|
MBMS all unmodified p-t-m services |
Not Present |
Rel-6 |
|
MBMS p-t-m activation time |
Not Present |
Rel-6 |
Contents of MBMS NEIGHBOURING CELL P-T-M RB INFORMATION message: UM
|
Information Element |
Value/remark |
Version |
|---|---|---|
|
Message type |
Rel-6 |
|
|
Neighbouring cell identity |
The intra-frequency cell id of the cell of the MBMS neighbouring cell referred to in the test procedure, obtained from the IE ‘Intra-frequency Cell Info list’ in SIB 11. |
Rel-6 |
|
Neighbouring cell’s S-CCPCH list |
1 entry in the list |
Rel-6 |
|
– Secondary CCPCH info |
Refers to the Physical channel identity being used for the service under test in the common RB info of the current cell |
Rel-6 |
|
– Secondary CCPCH Power Offset Difference |
Not Present |
Rel-6 |
|
– L1 combining |
Not Present |
Rel-6 |
|
– CHOICE L23 configuration |
SameAs Current cell |
Rel-6 |
|
– Current cell’s S-CCPCH |
1 (same as the S-CCPCH identity in the MBMS CURRENT CELL P-T-M RB INFORMATION) |
Rel-6 |
|
– MSCH configuration information |
Not Present |
Rel-6 |
Contents of MBMS UNMODIFIED SERVICES INFORMATION message: UM
|
Information Element |
Value/remark |
Version |
|---|---|---|
|
Message type |
Rel-6 |
|
|
Unmodified services list |
12 services by default. See NOTE 1. |
Rel-6 |
|
– MBMS Transmission identity |
Rel-6 |
|
|
– MBMS Service ID |
||
|
– MBMS Service ID |
‘000001’ |
Rel-6 |
|
– CHOICE PLMN identity |
SameAs-MIB |
Rel-6 |
|
– MBMS Session ID |
Value set according to table for condition A1 or A2 |
Rel-6 |
|
– MBMS required UE action |
Value set according to table for condition A1 or A2 |
Rel-6 |
|
– MBMS preferred frequency |
Not Present |
Rel-6 |
|
– MBMS Transmission identity |
Rel-6 |
|
|
– MBMS Service ID |
||
|
– MBMS Service ID |
‘000002’ |
Rel-6 |
|
– CHOICE PLMN identity |
SameAs-MIB |
Rel-6 |
|
– MBMS Session ID |
Value set according to table for condition A1 or A2 |
Rel-6 |
|
– MBMS required UE action |
Value set according to table for condition A1 or A2 |
Rel-6 |
|
– MBMS preferred frequency |
Not Present |
Rel-6 |
|
– MBMS Transmission identity |
Rel-6 |
|
|
– MBMS Service ID |
||
|
– MBMS Service ID |
‘000003’ |
Rel-6 |
|
– CHOICE PLMN identity |
SameAs-MIB |
Rel-6 |
|
– MBMS Session ID |
Value set according to table for condition A1 or A2 |
Rel-6 |
|
– MBMS required UE action |
Value set according to table for condition A1 or A2 |
Rel-6 |
|
– MBMS preferred frequency |
Not Present |
Rel-6 |
|
– MBMS Transmission identity |
Rel-6 |
|
|
– MBMS Service ID |
||
|
– MBMS Service ID |
‘000004’ |
Rel-6 |
|
– CHOICE PLMN identity |
SameAs-MIB |
Rel-6 |
|
– MBMS Session ID |
Value set according to table for condition A1 or A2 |
Rel-6 |
|
– MBMS required UE action |
Value set according to table for condition A1 or A2 |
Rel-6 |
|
– MBMS preferred frequency |
Not Present |
Rel-6 |
|
– MBMS Transmission identity |
Rel-6 |
|
|
– MBMS Service ID |
||
|
– MBMS Service ID |
‘000005’ |
Rel-6 |
|
– CHOICE PLMN identity |
SameAs-MIB |
Rel-6 |
|
– MBMS Session ID |
Value set according to table for condition A1 or A2 |
Rel-6 |
|
– MBMS required UE action |
Value set according to table for condition A1 or A2 |
Rel-6 |
|
– MBMS preferred frequency |
Not Present |
Rel-6 |
|
– MBMS Transmission identity |
Rel-6 |
|
|
– MBMS Service ID |
||
|
– MBMS Service ID |
‘000006’ |
Rel-6 |
|
– CHOICE PLMN identity |
SameAs-MIB |
Rel-6 |
|
– MBMS Session ID |
Value set according to table for condition A1 or A2 |
Rel-6 |
|
– MBMS required UE action |
Value set according to table for condition A1 or A2 |
Rel-6 |
|
– MBMS preferred frequency |
Not Present |
Rel-6 |
|
– MBMS Transmission identity |
Rel-6 |
|
|
– MBMS Service ID |
||
|
– MBMS Service ID |
‘000007’ |
Rel-6 |
|
– CHOICE PLMN identity |
SameAs-MIB |
Rel-6 |
|
– MBMS Session ID |
Value set according to table for condition A1 or A2 |
Rel-6 |
|
– MBMS required UE action |
Value set according to table for condition A1 or A2 |
Rel-6 |
|
– MBMS preferred frequency |
Not Present |
Rel-6 |
|
– MBMS Transmission identity |
Rel-6 |
|
|
– MBMS Service ID |
||
|
– MBMS Service ID |
‘000008’ |
Rel-6 |
|
– CHOICE PLMN identity |
SameAs-MIB |
Rel-6 |
|
– MBMS Session ID |
Value set according to table for condition A1 or A2 |
Rel-6 |
|
– MBMS required UE action |
Value set according to table for condition A1 or A2 |
Rel-6 |
|
– MBMS preferred frequency |
Not Present |
Rel-6 |
|
– MBMS Transmission identity |
Rel-6 |
|
|
– MBMS Service ID |
||
|
– MBMS Service ID |
‘000009’ |
Rel-6 |
|
– CHOICE PLMN identity |
SameAs-MIB |
Rel-6 |
|
– MBMS Session ID |
Value set according to table for condition A1 or A2 |
Rel-6 |
|
– MBMS required UE action |
Value set according to table for condition A1 or A2 |
Rel-6 |
|
– MBMS preferred frequency |
Not Present |
Rel-6 |
|
– MBMS Transmission identity |
Rel-6 |
|
|
– MBMS Service ID |
||
|
– MBMS Service ID |
‘00000A’ |
Rel-6 |
|
– CHOICE PLMN identity |
SameAs-MIB |
Rel-6 |
|
– MBMS Session ID |
Value set according to table for condition A1 or A2 |
Rel-6 |
|
– MBMS required UE action |
Value set according to table for condition A1 or A2 |
Rel-6 |
|
– MBMS preferred frequency |
Not Present |
Rel-6 |
|
– MBMS Transmission identity |
Rel-6 |
|
|
– MBMS Service ID |
||
|
– MBMS Service ID |
‘00000B’ |
Rel-6 |
|
– CHOICE PLMN identity |
SameAs-MIB |
Rel-6 |
|
– MBMS Session ID |
Value set according to table for condition A1 or A2 |
Rel-6 |
|
– MBMS required UE action |
Value set according to table for condition A1 or A2 |
Rel-6 |
|
– MBMS preferred frequency |
Not Present |
Rel-6 |
|
– MBMS Transmission identity |
Rel-6 |
|
|
– MBMS Service ID |
||
|
– MBMS Service ID |
‘00000C’ |
Rel-6 |
|
– CHOICE PLMN identity |
SameAs-MIB |
Rel-6 |
|
– MBMS Session ID |
Value set according to table for condition A1 or A2 |
Rel-6 |
|
– MBMS required UE action |
Value set according to table for condition A1 or A2 |
Rel-6 |
|
– MBMS preferred frequency |
Not Present |
Rel-6 |
|
Information Element |
Condition |
Value/remark |
Explanation |
|
– MBMS Session ID |
A1 |
Not Present |
Condition used when the session is currently not being transmitted |
|
– MBMS required UE action |
‘None’ |
||
|
– MBMS Session ID |
A2 |
‘01’ |
Condition used when the session is currently ongoing |
|
– MBMS required UE action |
‘Acquire PTM RB info’ |
NOTE 1: Any service ID which is included in MBMS MODIFIED SERVICES INFORMATION in the current modification period shall be Not Present in the list of services in this message.
Contents of MEASUREMENT CONTROL message: AM
|
Information Element |
Value/remark |
|---|---|
|
Message Type |
|
|
RRC transaction identifier |
Arbitrarily selects an unused integer between 0 to 3 |
|
Integrity check info |
|
|
– Message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
|
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
|
Measurement Identity |
1 |
|
Measurement Command |
Setup |
|
Measurement Reporting Mode |
|
|
– Measurement Report Transfer Mode |
Acknowledged mode RLC |
|
– Periodical Reporting/Event Trigger Reporting Mode |
Periodical reporting |
|
Additional measurement list |
Not Present |
|
CHOICE Measurement type |
Intra-frequency measurement |
|
– Intra-frequency measurement |
|
|
– Intra-frequency cell info list |
|
|
– CHOICE intra-frequency cell removal |
Not present |
|
– New intra-frequency cell |
|
|
– Intra-frequency cell-id |
1 |
|
– Cell info |
|
|
– Cell individual offset |
0 (0dB) |
|
– Reference time difference to cell |
Not Present |
|
– Read SFN number |
FALSE |
|
– CHOICE mode |
FDD |
|
– Primary CPICH info |
|
|
– Primary scrambling code |
Different from the Default setting in clause 6.1 (FDD) |
|
– Primary CPICH Tx power |
Not Present |
|
– TX Diversity indicator |
FALSE |
|
– Cells for measurement |
Not present |
|
– CSG Intrafrequency cell info |
Not present |
|
– Intra-frequency SI Acquisition |
Not present |
|
– Intra-frequency measurement quantity |
Not Present |
|
– Intra-frequency reporting quantity |
|
|
– Reporting quantities for active set cells |
|
|
– Cell synchronization information reporting indicator |
FALSE |
|
– Cell Identity reporting indicator |
TRUE |
|
– CPICH Ec/N0 reporting indicator |
FALSE |
|
– CPICH RSCP reporting indicator |
TRUE |
|
– Pathloss reporting indicator |
FALSE |
|
– Reporting quantities for monitored set cells |
|
|
– Cell synchronization information reporting indicator |
FALSE |
|
– Cell Identity reporting indicator |
TRUE |
|
– CPICH Ec/N0 reporting indicator |
FALSE |
|
– CPICH RSCP reporting indicator |
TRUE |
|
– Pathloss reporting indicator |
FALSE |
|
– Reporting quantities for detected set cells |
Not Present |
|
– Reporting cell status |
|
|
– CHOICE reported cell |
Report cell within active set and/or monitored cells on used frequency |
|
– Maximum number of reported cells |
2 |
|
– Measurement validity |
Not Present |
|
– CHOICE report criteria |
Periodic reporting criteria |
|
– Amount of reporting |
Infinity |
|
– Reporting interval |
64 s |
|
DPCH Compressed mode status info |
Not Present |
Contents of MEASUREMENT CONTROL FAILURE message: AM
|
Information Element |
Value/remark |
|
Message Type |
|
|
RRC transaction identifier |
Checked to see if it’s set to the identical value for the same IE in the downlink MEASUREMENT CONTROL message |
|
Integrity check info |
|
|
– Message authentication code |
This IE is checked to see if it is present. The value is compared against the XMAC-I value computed by SS. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
|
– RRC Message sequence number |
This IE is checked to see if it is present. The value is used by SS to compute the XMAC-I value. |
|
Failure cause |
See the test content |
Contents of MEASUREMENT REPORT message: AM
|
Information Element |
Value/remark |
Version |
|
Message Type |
||
|
Integrity check info |
||
|
– Message authentication code |
This IE is checked to see if it is present. The value is compared against the XMAC-I value computed by SS. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
|
|
– RRC Message sequence number |
This IE is checked to see if it is present. The value is used by SS to compute the XMAC-I value. |
|
|
Measurement identity |
1 |
|
|
Measured Results |
||
|
– Intra-frequency measured results |
||
|
– Cell measured results |
||
|
– Cell Identity |
Not present |
|
|
– Cell synchronization information |
Checked that this IE is absent |
|
|
– Primary CPICH info |
||
|
– Primary scrambling code |
Different from the Default setting in clause 6.1 (FDD) |
|
|
– CPICH Ec/N0 |
Checked that this IE is absent |
|
|
– CPICH RSCP |
Checked that this IE is present |
|
|
– Pathloss |
Checked that this IE is absent |
|
|
Measured results on RACH |
Checked that this IE is absent |
|
|
Additional measured results |
Checked that this IE is absent |
|
|
Event results |
Checked that this IE is absent |
|
|
GSM OTD reference cell |
Checked that this IE is absent |
Rel-4 |
|
CSG Proximity Indication |
FFS |
REL-9 |
|
Inter-RAT cell info indication |
Checked that this IE is absent |
Rel-5 |
Contents of PAGING TYPE 1 message: TM (Speech in CS)
|
Information Element |
Value/remark |
|
Message Type |
|
|
Paging record list |
|
|
– Paging record |
|
|
– CHOICE Used paging identity |
CN identity |
|
– Paging cause |
Terminating Conversational Call |
|
– CN domain identity |
CS domain |
|
– CHOICE UE identity |
|
|
– IMSI (GSM-MAP) |
Set to the same octet string as in the IMSI stored in the USIM card |
|
BCCH modification info |
Not Present |
|
ETWS information |
Not Present |
Contents of PAGING TYPE 1 message: TM (The others of speech in CS)
|
Information Element |
Value/remark |
|
Message Type |
|
|
Paging record list |
|
|
– Paging record |
|
|
– CHOICE Used paging identity |
CN identity |
|
– Paging cause |
Terminating Streaming Call |
|
– CN domain identity |
CS domain |
|
– CHOICE UE identity |
|
|
– IMSI (GSM-MAP) |
Set to the same octet string as in the IMSI stored in the USIM card |
|
BCCH modification info |
Not Present |
|
ETWS information |
Not Present |
Contents of PAGING TYPE 1 message: TM (Packet in PS)
|
Information Element |
Value/remark |
|
Message Type |
|
|
Paging record list |
|
|
– Paging record |
|
|
– CHOICE Used paging identity |
CN identity |
|
– Paging cause |
Terminating Interactive Call |
|
– CN domain identity |
PS domain |
|
– CHOICE UE identity |
|
|
– P-TMSI |
Use P-TMSI allocated by SS at initial attach. |
|
BCCH modification info |
Not Present |
|
ETWS information |
Not Present |
Contents of PAGING TYPE 1 message: TM (SMS in CS)
|
Information Element |
Value/remark |
|
Message Type |
|
|
Paging record list |
|
|
– Paging record |
|
|
– CHOICE Used paging identity |
CN identity |
|
– Paging cause |
Terminating Low Priority Signalling |
|
– CN domain identity |
CS domain |
|
– CHOICE UE identity |
|
|
– IMSI (GSM-MAP) |
Set to the same octet string as in the IMSI stored in the TEST USIM card |
|
BCCH modification info |
Not Present |
|
ETWS information |
Not Present |
Contents of PAGING TYPE 1 message: TM (SMS in PS)
|
Information Element |
Value/remark |
|
Message Type |
|
|
Paging record list |
|
|
– Paging record |
|
|
– CHOICE Used paging identity |
CN identity |
|
– Paging cause |
Terminating Low Priority Signalling |
|
– CN domain identity |
PS domain |
|
– CHOICE UE identity |
|
|
– IMSI (GSM-MAP) |
Set to the same octet string as in the IMSI stored in the TEST USIM card |
|
BCCH modification info |
Not Present |
|
ETWS information |
Not Present |
Contents of PAGING TYPE 2 message: AM (Speech in CS)
|
Information Element |
Value/remark |
|
Message Type |
|
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
|
Integrity check info |
|
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
|
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
|
Paging cause |
Terminating Conversational Call |
|
CN domain identity |
CS domain |
|
Paging record type identifier |
Select the same type as in the IE "Initial UE Identity" in RRC CONNECTION REQUEST" message. |
Contents of PHYSICAL CHANNEL RECONFIGURATION message: AM or UM
|
Information Element |
Condition |
Value/remark |
Version |
|---|---|---|---|
|
Message Type |
A1, A2, A3, A4, A5, A6, A7, A8, A9, A10 |
||
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
||
|
Integrity check info |
|||
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
||
|
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
||
|
Integrity protection mode info |
Not Present |
||
|
Ciphering mode info |
Not Present |
||
|
Activation time |
A1, A2, A3 |
(256+CFN-(CFN MOD 8 + 8))MOD 256 |
|
|
Activation time |
A4, A5, A6, A7, A8, A9, A10 |
Not Present |
|
|
Delay restriction flag |
A1, A2, A3, A4, A5, A6, A7, A8, A9, A10 |
Not Present |
Rel-6 |
|
New U-RNTI |
Not Present |
||
|
New C-RNTI |
A1, A2, A3, A4, A7, A8, A9, A10 |
Not Present |
|
|
New C-RNTI |
A5, A6 |
‘1010 1010 1010 1010’ |
|
|
New DSCH-RNTI |
A1, A2, A3, A4, A5, A6, A7, A8, A9, A10 |
Not Present |
R99 and Rel-4 only |
|
New H-RNTI |
A1, A2, A3, A4, A5, A6, A7, A8, A9, A10 |
Not Present |
Rel-5 |
|
New Primary E-RNTI |
Not Present |
Rel-6 |
|
|
New Secondary E-RNTI |
Not Present |
Rel-6 |
|
|
RRC State indicator |
A1, A2, A3, A4 |
CELL_DCH |
|
|
RRC State indicator |
A5, A6 |
CELL_FACH |
|
|
RRC State indicator |
A7, A8 |
URA_PCH |
|
|
RRC State indicator |
A9, A10 |
CELL_PCH |
|
|
UE Mobility State Indicator |
Not Present |
Rel-7 |
|
|
UTRAN DRX cycle length coefficient |
A1, A2, A3, A4, A5, A6 |
Not Present |
|
|
UTRAN DRX cycle length coefficient |
A7, A8, A9, A10 |
3 |
|
|
CN information info |
Not Present |
||
|
URA identity |
Not Present |
||
|
RNC support for change of UE capability |
Not Present |
Rel-7 |
|
|
Reconfiguration in response to requested change of UE capability |
Not Present |
Rel-7 |
|
|
Downlink counter synchronization info |
Not Present |
||
|
Frequency info |
A1, A2, A3, A4, A5 |
||
|
– UARFCN uplink (Nu) |
Not present Absence of this IE is equivalent to applying the default duplex distance defined for the operating frequency according to 3GPP TS 25.101 [11] |
||
|
– UARFCN downlink (Nd) |
Reference to clause 5.1 Test frequencies |
||
|
Frequency info |
A6, A7, A8, A9, A10 |
Not Present |
|
|
DTX-DRX timing information |
Not Present |
Rel-7 |
|
|
DTX-DRX Information |
Not Present |
Rel-7 |
|
|
HS-SCCH less Information |
Not Present |
Rel-7 |
|
|
MIMO parameters |
Not Present |
Rel-7 |
|
|
HARQ Info |
Not Present |
Rel-7 |
|
|
Maximum allowed UL TX power |
33dBm |
||
|
CHOICE channel requirement |
A5, A6, A7, A8, A9, A10 |
Not Present |
|
|
CHOICE channel requirement |
A1, A2, A3, A4 |
Uplink DPCH info |
|
|
– Uplink DPCH power control info |
|||
|
– DPCCH power offset |
-40 (-80dB) |
||
|
– PC Preamble |
1 frame |
||
|
– SRB delay |
7 frames |
||
|
– Power Control Algorithm |
Algorithm1 |
||
|
– TPC step size |
0 (1dB) |
||
|
– ACK |
Not Present |
Rel-5 |
|
|
– NACK |
Not Present |
Rel-5 |
|
|
– Ack-Nack repetition factor |
Not Present |
Rel-5 |
|
|
– HARQ_preamble_mode |
0 |
Rel-6 |
|
|
– Scrambling code type |
Long |
||
|
– Scrambling code number |
0 (0 to 16777215) |
||
|
– Number of DPDCH |
Not Present(1) |
||
|
– spreading factor |
Reference to clause 6.10 Parameter Set |
||
|
– TFCI existence |
Reference to clause 6.10 Parameter Set |
||
|
– Number of FBI bit |
Reference to clause 6.10 Parameter Set |
||
|
– Number of TPC bits |
Not Present |
Rel-7 |
|
|
– Puncturing Limit |
Reference to clause 6.10 Parameter Set |
||
|
E-DCH Info |
Not Present |
Rel-6 |
|
|
CHOICE Mode |
A1, A2, A3, A4, A5, A6, A7, A8, A9, A10 |
FDD |
|
|
– Downlink PDSCH information |
Not Present |
R99 and Rel-4 only |
|
|
Downlink HS-PDSCH Information |
A1, A2, A3, A4, A5, A6, A7, A8, A9, A10 |
Not Present |
Rel-5 |
|
Downlink information common for all radio links |
A1, A2, A3 |
||
|
– Downlink DPCH info common for all RL |
|||
|
– Timing indicator |
Maintain |
||
|
– CFN-targetSFN frame offset |
Not Present |
||
|
– Downlink DPCH power control information |
|||
|
– DPC mode |
0 (single) |
||
|
– CHOICE mode |
FDD |
||
|
– Power offset PPilot-DPDCH |
0 |
||
|
– DL rate matching restriction information |
Not Present |
||
|
– Spreading factor |
Reference to clause 6.10 Parameter Set |
||
|
– Fixed or Flexible Position |
Reference to clause 6.10 Parameter Set |
||
|
– TFCI existence |
Reference to clause 6.10 Parameter Set |
||
|
– CHOICE SF |
Reference to clause 6.10 Parameter Set |
||
|
– DPCH compressed mode info |
Not Present |
||
|
– TX Diversity mode |
None |
||
|
– SSDT information |
Not Present |
R99 and Rel-4 only |
|
|
– Default DPCH Offset Value |
Not Present |
||
|
– MAC-hs reset indicator |
Not Present |
Rel-5 |
|
|
Downlink information common for all radio links |
A4 |
||
|
– Downlink DPCH info common for all RL |
|||
|
– Timing indicator |
Initialize |
||
|
– CFN-targetSFN frame offset |
Not Present |
||
|
– Downlink DPCH power control information |
|||
|
– DPC mode |
0 (single) |
||
|
– CHOICE mode |
FDD |
||
|
– Power offset PPilot-DPDCH |
0 |
||
|
– DL rate matching restriction information |
Not Present |
||
|
– Spreading factor |
Reference to clause 6.10 Parameter Set |
||
|
– Fixed or Flexible Position |
Reference to clause 6.10 Parameter Set |
||
|
– TFCI existence |
Reference to clause 6.10 Parameter Set |
||
|
– CHOICE SF |
Reference to clause 6.10 Parameter Set |
||
|
– DPCH compressed mode info |
Not Present |
||
|
– TX Diversity mode |
None |
||
|
– SSDT information |
Not Present |
R99 and Rel-4 only |
|
|
– Default DPCH Offset Value |
Arbitrary set to value 0..306688 by step of 512 |
||
|
– MAC-hs reset indicator |
Not Present |
Rel-5 |
|
|
Downlink information common for all radio links |
A5, A6, A7, A8, A9, A10 |
Not Present |
|
|
Downlink information for each radio links |
A1, A2,A3 |
||
|
– Choice mode |
FDD |
||
|
– Primary CPICH info |
|||
|
– Primary scrambling code |
Ref. to the Default setting in clause 6.1 (FDD) |
||
|
– PDSCH with SHO DCH info |
Not Present |
R99 and Rel-4 only |
|
|
– PDSCH code mapping |
Not Present |
R99 and Rel-4 only |
|
|
– Serving HS-DSCH radio link indicator |
FALSE |
Rel-5 |
|
|
– Serving E-DCH radio link indicator |
FALSE |
Rel-6 |
|
|
– Downlink DPCH info for each RL |
|||
|
– CHOICE mode |
FDD |
||
|
– Primary CPICH usage for channel estimation |
Primary CPICH may be used |
||
|
– DPCH frame offset |
Set to value : Default DPCH Offset Value (as currently stored in SS) mod 38 400 |
||
|
– Secondary CPICH info |
Not Present |
||
|
– DL channelisation code |
|||
|
– Secondary scrambling code |
5 |
||
|
– Spreading factor |
Reference to clause 6.10 Parameter Set |
||
|
– Code number |
0 |
||
|
– Scrambling code change |
Set to value Default1: No code change (if the UE has a compressed mode pattern sequence configured in variable TGPS_IDENTITY or included in the message including IE "Downlink DPCH info for each RL", which is using compressed mode method "SF/2") Set to value Default2: OMIT (otherwise) |
||
|
– TPC combination index |
0 |
||
|
– SSDT Cell Identity |
Not Present |
R99 and Rel-4 only |
|
|
– Closed loop timing adjustment mode |
Not Present |
||
|
– E-AGCH Info |
Not Present |
Rel-6 |
|
|
– E-HICH Information |
Not Present |
Rel-6 |
|
|
– E-RGCH Information |
Not Present |
Rel-6 |
|
|
– SCCPCH information for FACH |
Not Present |
R99 and Rel-4 only |
|
|
Downlink information for each radio links |
A4 |
||
|
– Choice mode |
FDD |
||
|
– Primary CPICH info |
|||
|
– Primary scrambling code |
Ref. to the Default setting in clause 6.1 (FDD) |
||
|
– PDSCH with SHO DCH info |
Not Present |
R99 and Rel-4 only |
|
|
– PDSCH code mapping |
Not Present |
R99 and Rel-4 only |
|
|
– Serving HS-DSCH radio link indicator |
FALSE |
Rel-5 |
|
|
– Serving E-DCH radio link indicator |
FALSE |
Rel-6 |
|
|
– Downlink DPCH info for each RL |
|||
|
– CHOICE mode |
FDD |
||
|
– Primary CPICH usage for channel estimation |
Primary CPICH may be used |
||
|
– DPCH frame offset |
Set to value : Default DPCH Offset Value mod 38 400 |
||
|
– Secondary CPICH info |
Not Present |
||
|
– DL channelisation code |
|||
|
– Secondary scrambling code |
5 |
||
|
– Spreading factor |
Reference to clause 6.10 Parameter Set |
||
|
– Code number |
0 |
||
|
– Scrambling code change |
Set to value Default1: No code change (if the UE has a compressed mode pattern sequence configured in variable TGPS_IDENTITY or included in the message including IE "Downlink DPCH info for each RL", which is using compressed mode method "SF/2") Set to value Default2: OMIT (otherwise) |
||
|
– TPC combination index |
0 |
||
|
– SSDT Cell Identity |
Not Present |
R99 and Rel-4 only |
|
|
– Closed loop timing adjustment mode |
Not Present |
||
|
– E-AGCH Info |
Not Present |
Rel-6 |
|
|
– E-HICH Information |
Not Present |
Rel-6 |
|
|
– E-RGCH Information |
Not Present |
Rel-6 |
|
|
– SCCPCH information for FACH |
Not Present |
R99 and Rel-4 only |
|
|
– Downlink information for each radio link |
A5 |
||
|
– Choice mode |
FDD |
||
|
– Primary CPICH info |
|||
|
– Primary scrambling code |
Ref. to the Default setting in clause 6.1 (FDD) |
||
|
– PDSCH with SHO DCH info |
Not Present |
R99 and Rel-4 only |
|
|
– PDSCH code mapping |
Not Present |
R99 and Rel-4 only |
|
|
– Serving HS-DSCH radio link indicator |
FALSE |
Rel-5 |
|
|
– Serving E-DCH radio link indicator |
FALSE |
Rel-6 |
|
|
– Downlink DPCH info for each RL |
Not Present |
||
|
– E-AGCH Info |
Not Present |
Rel-6 |
|
|
– E-HICH Information |
Not Present |
Rel-6 |
|
|
– E-RGCH Information |
Not Present |
Rel-6 |
|
|
– SCCPCH Information for FACH |
Not Present |
R99 and Rel-4 only |
|
|
– Downlink information for each radio link |
A6, A7, A8, A9, A10 |
Not Present |
|
|
MBMS PL Service Restriction Information |
A1, A2, A3, A4, A5, A6, A7, A8, A9, A10 |
Not Present |
Rel-6 |
|
Condition |
Explanation |
|
A1 |
This IE need for "Non speech in CS" |
|
A2 |
This IE need for "Speech in CS" |
|
A3 |
This IE need for "Packet to CELL_DCH from CELL_DCH in PS" |
|
A4 |
This IE need for "Packet to CELL_DCH from CELL_FACH in PS" |
|
A5 |
This IE need for "Packet to CELL_FACH from CELL_DCH in PS" |
|
A6 |
This IE need for "Packet to CELL_FACH from CELL_FACH in PS" |
|
A7 |
This IE need for "Packet to URA_PCH from CELL_FACH in PS" |
|
A8 |
This IE need for "Packet to URA_PCH from CELL_DCH in PS" |
|
A9 |
This IE need for "Packet to CELL_PCH from CELL_FACH in PS" |
|
A10 |
This IE need for "Packet to CELL_PCH from CELL_DCH in PS" |
Contents of PHYSICAL CHANNEL RECONFIGURATION COMPLETE message: AM
|
Information Element |
Value/remark |
|
Message Type |
|
|
RRC transaction identifier |
Checked to see if it’s set to identical value of the same IE in the downlink PHYSICAL CHANNEL RECONFIGURATION message |
|
Integrity check info |
|
|
– Message authentication code |
This IE is checked to see if it is present. The value is compared against the XMAC-I value computed by SS. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
|
– RRC Message sequence number |
This IE is checked to see if it is present. The value is used by SS to compute the XMAC-I value. |
|
Uplink integrity protection activation info |
Not checked |
|
CHOICE mode |
FDD |
|
Deferred measurement control reading |
Not present for Rel-7 or later, otherwise Not checked |
|
COUNT-C activation time |
Not checked |
|
Radio bearer uplink ciphering activation time info |
Not checked |
|
Uplink counter synchronization info |
Not present |
Contents of PHYSICAL CHANNEL RECONFIGURATION FAILURE message: AM
|
Information Element |
Value/remark |
|
Message Type |
|
|
RRC transaction identifier |
Checked to see if it is set to identical value of the same IE in the downlink PHYSICAL CHANNEL RECONFIGURATION message. |
|
Integrity check info |
|
|
– Message authentication code |
This IE is checked to see if it is present. The value is compared against the XMAC-I value computed by SS. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
|
– RRC Message sequence number |
This IE is checked to see if it is present. The value is used by SS to compute the XMAC-I value. |
|
Failure cause |
Checked to see if it meets test requirement |
Contents of RADIO BEARER SETUP message: AM or UM
|
Information Element |
Condition |
Value/remark |
Version |
Index |
|||||
|---|---|---|---|---|---|---|---|---|---|
|
Message Type |
A1, A2, A3, A4, A5, A6, A7, A8, A11 |
RBS-003 |
|||||||
|
, A9, A10 |
Rel-5 |
RBS-004 |
|||||||
|
, A12, A13, A14, A15, A16 |
Rel-6 |
RBS-005 |
|||||||
|
, A17, A17a, A17b, A17c, A17d, A17e, A17f, A18, A19, A19a, A19b, A20, A21, A22 |
Rel-7 |
RBS-006 |
|||||||
|
, A23, A24,A28a |
Rel-7 Rel-8 |
RBS-007 |
|||||||
|
, A25, A25a, A25b, A26, A27, A28, A29, A30 |
Rel-8 |
RBS-008 |
|||||||
|
, A25c, A31, A32 , A33, A34, A35, A36, A37 A38, A39, A40, A41, A42, A43, A44, A45 |
Rel-9 Rel-10 Rel-11 |
RBS-009 |
|||||||
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
RBS-010 |
|||||||
|
Integrity check info |
RBS-011 |
||||||||
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
RBS-012 |
|||||||
|
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
RBS-013 |
|||||||
|
Integrity protection mode info |
Not Present |
RBS-014 |
|||||||
|
Ciphering mode info |
Not Present |
RBS-015 |
|||||||
|
Sr-vcc-Info |
Not Present |
||||||||
|
Activation time |
A1, A2, A3, A11 |
(256+CFN-(CFN MOD 8 + 8)) MOD 256 |
RBS-016 |
||||||
|
, A9 |
Rel-5 |
RBS-017 |
|||||||
|
, A12, A13, A14, A15, A16 |
Rel-6 |
RBS-018 |
|||||||
|
, A17, A17a, A17b, A17d, A17e, A17f, A18, A19, A19a, A19b, A20, A21, A22 |
Rel-7 |
RBS-019 |
|||||||
|
, A23, A28a |
Rel-7 Rel-8 |
RBS-020 |
|||||||
|
, A25, A25a, A25b, A26, A27, A27a, A28 |
Rel-8 |
RBS-021 |
|||||||
|
, A25c, A31, A32 , A33, A34, A35, A36, A37 A38, A39, A40, A41, A42, A43, A44, A45 |
Rel-9 Rel-10 Rel-11 |
RBS-021b |
|||||||
|
Activation time |
A4, A5, A6, A7, A8 |
Not Present |
RBS-022 |
||||||
|
A10, A24 |
Rel-5 |
RBS-023 |
|||||||
|
, A29, A30 |
Rel-8 |
RBS-024 |
|||||||
|
New U-RNTI |
A1, A2, A3, A4, A5, A6, A7, A8, A11 |
Not Present |
RBS-026 |
||||||
|
, A9, A10 |
Rel-5 |
RBS-027 |
|||||||
|
, A12, A13, A14, A15, A16 |
Rel-6 |
RBS-028 |
|||||||
|
, A17, A17a, A17b, A17c, A17d, A17e, A17f, A18, A19, A19a, A19b, A20, A21, A22, A24 |
Rel-7 |
RBS-029 |
|||||||
|
, A23, A28a |
Rel-7 Rel-8 |
RBS-030 |
|||||||
|
, A25, A25a, A25b, A26, A27, A27a, A28, A29, A30 |
Rel-8 |
RBS-031 |
|||||||
|
, A25c, A31, A32 , A33, A34, A35, A36, A37 A38, A39, A40, A41, A42, A43, A44, A45 |
Rel-9 Rel-10 Rel-11 |
RBS-032 |
|||||||
|
New C-RNTI |
A1, A2, A3, A4, A7, A8, A11 |
Not Present |
RBS-033 |
||||||
|
, A9, A10 |
Rel-5 |
RBS-034 |
|||||||
|
, A12, A13, A14, A15, A16 |
Rel-6 |
RBS-035 |
|||||||
|
, A17, A17a, A17b, A17c, A17d, A17e, A17f, A18, A19, A19a, A19b, A20, A21, A22, A24 |
Rel-7 |
RBS-036 |
|||||||
|
, A23, A28a |
Rel-7 Rel-8 |
RBS-037 |
|||||||
|
, A25, A25a, A25b, A26, A27, A27a, A28, A29, A30 |
Rel-8 |
RBS-038 |
|||||||
|
, A25c, A31, A32 , A33, A34, A35, A36, A37 A38, A39, A40, A41, A42, A43, A44, A45 |
Rel-9 Rel-10 Rel-11 |
RBS-039 |
|||||||
|
New C-RNTI |
A5, A6 |
‘1010 1010 1010 1010’ |
RBS-040 |
||||||
|
New DSCH-RNTI |
A1, A2, A3, A4, A5, A6, A7, A8, A11 |
Not Present |
R99 and Rel-4 only |
RBS-041 |
|||||
|
New H-RNTI |
A1, A2, A3, A4, A5, A6, A7, A8, A11 |
Not Present |
Rel-5 |
RBS-042 |
|||||
|
New H-RNTI |
A9, A10 |
‘1010 1010 1010 1010’ |
Rel-5 |
RBS-045 |
|||||
|
A12, A13, A14, A15, A16 |
Rel-6 |
RBS-046 |
|||||||
|
, A17, A17a, A17b, A17c, A17d, A17e, A17f, A18, A19, A19a, A19b, A20, A21, A22, A24 |
Rel-7 |
RBS-047 |
|||||||
|
, A23, A28a |
Rel-7 Rel-8 |
RBS-048 |
|||||||
|
, A25, A25a, A25b, A26, A27, A27a, A28 |
Rel-8 |
RBS-049 |
|||||||
|
, A25c, A29, A30, A31, A32 , A33, A34, A35, A36, A37 A38, A39, A40, A41, A42, A43, A44, A45 |
Rel-9 Rel-10 Rel-11 |
RBS-049b |
|||||||
|
New Primary E-RNTI |
A1, A2, A3, A4, A5, A6, A7, A8, A9, A10, A11 |
Not Present |
Rel-6 |
RBS-050 |
|||||
|
, A17, A17a, A18, A24 |
Rel-7 |
RBS-051 |
|||||||
|
, A25a, A28 |
Rel-8 |
RBS-052 |
|||||||
|
New Primary E-RNTI |
A12, A13, A14, A15, A16, A17b, A17c, A17d, A17e A17f, |
‘1010 1010 1010 1010’ |
Rel-6 |
RBS-054 |
|||||
|
, A19, A19a, A19b, A20, A21, A22 |
Rel-7 |
RBS-055 |
|||||||
|
, A23, A28a |
Rel-7 Rel-8 |
RBS-056 |
|||||||
|
, A25, A25b, A26, A27, A27a, A29, A30 |
Rel-8 |
RBS-057 |
|||||||
|
A25c, A31, A32 , A33, A34, A35, A36, A37 A38, A39, A40, A41, A42, A43, A44, A45 |
Rel-9 Rel-10 Rel-11 |
RBS-057b |
|||||||
|
New Secondary E-RNTI |
A1, A2, A3, A4, A5, A6, A7, A8, A9, A10, A11, A12, A13, A14, A15, A16 |
Not Present |
Rel-6 |
RBS-058 |
|||||
|
, A17, A17a, A17b, A17c, A17d, A17e, A17f, A18, A19, A19a, A19b, A20, A21, A22, A24 |
Rel-7 |
RBS-059 |
|||||||
|
, A23, A28a |
Rel-7 Rel-8 |
RBS-060 |
|||||||
|
, A25, A25a, A25b, A26, A27, A27a, A28, A29, A30 |
Rel-8 |
RBS-061 |
|||||||
|
, A31, A32 , A33, A34, A35, A36, A37 A38, A39, A40, A41, A42, A43, A44, A45 |
Rel-9 Rel-10 Rel-11 |
RBS-062 |
|||||||
|
RRC State indicator |
A1, A2, A3, A4, A7, A8, A11 |
CELL_DCH |
RBS-063 |
||||||
|
, A9, A10 |
Rel-5 |
RBS-064 |
|||||||
|
, A12, A13, A14, A15, A16 |
Rel-6 |
RBS-065 |
|||||||
|
, A17, A17a, A17b, A17c, A17d, A17e, A17f, A18, A19, A19a, A19b, A20, A21, A22 |
Rel-7 |
RBS-066 |
|||||||
|
, A23, A28a |
Rel-7 Rel-8 |
RBS-067 |
|||||||
|
, A25, A25a, A25b, A26, A27, A27a, A28, A30 |
Rel-8 |
RBS-068 |
|||||||
|
, A25c, A31, A32 , A33, A34, A35, A36, A37 A38, A39, A40, A41, A42, A43, A44, A45 |
Rel-9 Rel-10 Rel-11 |
RBS-069 |
|||||||
|
RRC State indicator |
A5, A6, |
CELL_FACH |
RBS-070 |
||||||
|
A24 |
Rel-7 |
RBS-071 |
|||||||
|
A29 |
RBS-072 |
||||||||
|
UTRAN DRX cycle length coefficient |
A1, A2, A3, A4, A5, A6, A7, A8, A11 |
Not Present |
RBS-073 |
||||||
|
, A9, A10 |
Rel-5 |
RBS-074 |
|||||||
|
, A12, A13, A14, A15, A16 |
Rel-6 |
RBS-075 |
|||||||
|
, A17, A17a, A17b, A17c, A17d, A17e, A17f, A18, A19, A19a, A19b, A20, A21, A22, A24 |
Rel-7 |
RBS-076 |
|||||||
|
, A23, A28a |
Rel-7 Rel-8 |
RBS-077 |
|||||||
|
, A25, A25a, A25b, A26, A27, A27a, A28, A29, A30 |
Rel-8 |
RBS-078 |
|||||||
|
, A25c, A31, A32 , A33, A34, A35, A36, A37 A38, A39, A40, A41, A42, A43, A44, A45 |
Rel-9 Rel-10 Rel-11 |
RBS-079 |
|||||||
|
CN information info |
Not Present |
RBS-080 |
|||||||
|
URA identity |
Not Present |
RBS-081 |
|||||||
|
RNC support for change of UE capability |
Not Present |
Rel-7 |
RBS-082 |
||||||
|
CHOICE Specification mode |
Complete specification |
Rel-6 |
RBS-083 |
||||||
|
– Signalling RB information to setup |
Not Present |
RBS-084 |
|||||||
|
– RAB information for setup |
A1, A7 |
RBS-085 |
|||||||
|
– RAB info |
RBS-086 |
||||||||
|
– RAB identity |
0000 0001B The first/ leftmost bit of the bit string contains the most significant bit of the RAB identity. |
RBS-087 |
|||||||
|
– CN domain identity |
CS domain |
RBS-088 |
|||||||
|
– NAS Synchronization Indicator |
Not Present |
RBS-089 |
|||||||
|
– Re-establishment timer |
useT314 |
RBS-090 |
|||||||
|
– RB information to setup |
|
RBS-091 |
|||||||
|
– RB identity |
10 |
RBS-092 |
|||||||
|
– PDCP info |
Not Present |
RBS-093 |
|||||||
|
– CHOICE RLC info type |
RLC info |
RBS-094 |
|||||||
|
– CHOICE Uplink RLC mode |
TM RLC |
RBS-095 |
|||||||
|
– Transmission RLC discard |
Not Present |
RBS-096 |
|||||||
|
– Segmentation indication |
FALSE |
RBS-097 |
|||||||
|
– CHOICE Downlink RLC mode |
TM RLC |
RBS-098 |
|||||||
|
– Segmentation indication |
FALSE |
RBS-099 |
|||||||
|
– RB mapping info |
|
RBS-100 |
|||||||
|
– Information for each multiplexing option |
|
RBS-101 |
|||||||
|
– RLC logical channel mapping indicator |
Not Present |
RBS-102 |
|||||||
|
– Number of uplink RLC logical channels |
1 |
RBS-103 |
|||||||
|
– Uplink transport channel type |
DCH |
RBS-104 |
|||||||
|
– UL Transport channel identity |
1 |
RBS-105 |
|||||||
|
– Logical channel identity |
Not Present |
RBS-106 |
|||||||
|
– CHOICE RLC size list |
Configured |
RBS-107 |
|||||||
|
– MAC logical channel priority |
7 |
RBS-108 |
|||||||
|
– Downlink RLC logical channel info |
|
RBS-109 |
|||||||
|
– Number of downlink RLC logical channels |
1 |
RBS-110 |
|||||||
|
– Downlink transport channel type |
DCH |
RBS-111 |
|||||||
|
– DL DCH Transport channel identity |
6 |
RBS-112 |
|||||||
|
– DL DSCH Transport channel identity |
Not Present |
RBS-113 |
|||||||
|
– Logical channel identity |
Not Present |
RBS-114 |
|||||||
|
– RAB information for setup |
A2, A8 |
RBS-115 |
|||||||
|
– RAB info |
RBS-116 |
||||||||
|
– RAB identity |
0000 0001B The first/ leftmost bit of the bit string contains the most significant bit of the RAB identity. |
RBS-117 |
|||||||
|
– CN domain identity |
CS domain |
RBS-118 |
|||||||
|
– NAS Synchronization Indicator |
Not Present |
RBS-119 |
|||||||
|
– Re-establishment timer |
useT314 |
RBS-120 |
|||||||
|
– RB information to setup |
|
RBS-121 |
|||||||
|
– RB identity |
10 |
RBS-122 |
|||||||
|
– PDCP info |
Not Present |
RBS-123 |
|||||||
|
– CHOICE RLC info type |
RLC info |
RBS-124 |
|||||||
|
– CHOICE Uplink RLC mode |
TM RLC |
RBS-125 |
|||||||
|
– Transmission RLC discard |
Not Present |
RBS-126 |
|||||||
|
– Segmentation indication |
FALSE |
RBS-127 |
|||||||
|
– CHOICE Downlink RLC mode |
TM RLC |
RBS-128 |
|||||||
|
– Segmentation indication |
FALSE |
RBS-129 |
|||||||
|
– RB mapping info |
RBS-130 |
||||||||
|
– Information for each multiplexing option |
RBS-131 |
||||||||
|
– RLC logical channel mapping indicator |
Not Present |
RBS-132 |
|||||||
|
– Number of uplink RLC logical channels |
1 |
RBS-133 |
|||||||
|
– Uplink transport channel type |
DCH |
RBS-134 |
|||||||
|
– UL Transport channel identity |
1 |
RBS-135 |
|||||||
|
– Logical channel identity |
Not Present |
RBS-136 |
|||||||
|
– CHOICE RLC size list |
Configured |
RBS-137 |
|||||||
|
– MAC logical channel priority |
6 |
RBS-138 |
|||||||
|
– Downlink RLC logical channel info |
|
RBS-139 |
|||||||
|
– Number of downlink RLC logical channels |
1 |
RBS-140 |
|||||||
|
– Downlink transport channel type |
DCH |
RBS-141 |
|||||||
|
– DL DCH Transport channel identity |
6 |
RBS-142 |
|||||||
|
– DL DSCH Transport channel identity |
Not Present |
RBS-143 |
|||||||
|
– Logical channel identity |
Not Present |
RBS-144 |
|||||||
|
– RB identity |
11 |
RBS-145 |
|||||||
|
– PDCP info |
Not Present |
RBS-146 |
|||||||
|
– CHOICE RLC info type |
RLC info |
RBS-147 |
|||||||
|
– CHOICE Uplink RLC mode |
TM RLC |
RBS-148 |
|||||||
|
– Transmission RLC discard |
Not Present |
RBS-149 |
|||||||
|
– Segmentation indication |
FALSE |
RBS-150 |
|||||||
|
– CHOICE Downlink RLC mode |
TM RLC |
RBS-151 |
|||||||
|
– Segmentation indication |
FALSE |
RBS-152 |
|||||||
|
– RB mapping info |
RBS-153 |
||||||||
|
– Information for each multiplexing option |
RBS-154 |
||||||||
|
– RLC logical channel mapping indicator |
Not Present |
RBS-155 |
|||||||
|
– Number of uplink RLC logical channels |
1 |
RBS-156 |
|||||||
|
– Uplink transport channel type |
DCH |
RBS-157 |
|||||||
|
– UL Transport channel identity |
2 |
RBS-158 |
|||||||
|
– Logical channel identity |
Not Present |
RBS-159 |
|||||||
|
– CHOICE RLC size list |
Configured |
RBS-160 |
|||||||
|
– MAC logical channel priority |
6 |
RBS-161 |
|||||||
|
– Downlink RLC logical channel info |
RBS-162 |
||||||||
|
– Number of downlink RLC logical channels |
1 |
RBS-163 |
|||||||
|
– Downlink transport channel type |
DCH |
RBS-164 |
|||||||
|
– DL DCH Transport channel identity |
7 |
RBS-165 |
|||||||
|
– DL DSCH Transport channel identity |
Not Present |
RBS-166 |
|||||||
|
– Logical channel identity |
Not Present |
RBS-167 |
|||||||
|
– RB identity |
12 |
RBS-168 |
|||||||
|
– PDCP info |
Not Present |
RBS-169 |
|||||||
|
– CHOICE RLC info type |
RLC info |
RBS-170 |
|||||||
|
– CHOICE Uplink RLC mode |
TM RLC |
RBS-171 |
|||||||
|
– Transmission RLC discard |
Not Present |
RBS-172 |
|||||||
|
– Segmentation indication |
FALSE |
RBS-173 |
|||||||
|
– CHOICE Downlink RLC mode |
TM RLC |
RBS-174 |
|||||||
|
– Segmentation indication |
FALSE |
RBS-175 |
|||||||
|
– RB mapping info |
RBS-176 |
||||||||
|
– Information for each multiplexing option |
RBS-177 |
||||||||
|
– RLC logical channel mapping indicator |
Not Present |
RBS-178 |
|||||||
|
– Number of uplink RLC logical channels |
1 |
RBS-179 |
|||||||
|
– Uplink transport channel type |
DCH |
RBS-180 |
|||||||
|
– UL Transport channel identity |
3 |
RBS-181 |
|||||||
|
– Logical channel identity |
Not Present |
RBS-182 |
|||||||
|
– CHOICE RLC size list |
Configured |
RBS-183 |
|||||||
|
– MAC logical channel priority |
6 |
RBS-184 |
|||||||
|
– Downlink RLC logical channel info |
RBS-185 |
||||||||
|
– Number of downlink RLC logical channels |
1 |
RBS-186 |
|||||||
|
– Downlink transport channel type |
DCH |
RBS-187 |
|||||||
|
– DL DCH Transport channel identity |
8 |
RBS-188 |
|||||||
|
– DL DSCH Transport channel identity |
Not Present |
RBS-189 |
|||||||
|
– Logical channel identity |
Not Present |
RBS-190 |
|||||||
|
– RAB information for setup |
A3, A4, A5, A6 |
RBS-191 |
|||||||
|
– RAB info |
(AM DTCH for PS domain) |
RBS-192 |
|||||||
|
– RAB identity |
0000 0101B The first/ leftmost bit of the bit string contains the most significant bit of the RAB identity. |
RBS-193 |
|||||||
|
– CN domain identity |
PS domain |
RBS-194 |
|||||||
|
– NAS Synchronization Indicator |
Not Present |
RBS-195 |
|||||||
|
– Re-establishment timer |
useT315 |
RBS-196 |
|||||||
|
– RB information to setup |
RBS-197 |
||||||||
|
– RB identity |
20 |
RBS-198 |
|||||||
|
– PDCP info |
RBS-199 |
||||||||
|
– Support for lossless SRNS relocation |
FALSE |
RBS-200 |
|||||||
|
– Max PDCP SN window size |
Not present |
RBS-201 |
|||||||
|
– PDCP PDU header |
Absent |
RBS-202 |
|||||||
|
– Header compression information |
Not present |
RBS-203 |
|||||||
|
– CHOICE RLC info type |
RLC info |
RBS-204 |
|||||||
|
– CHOICE Uplink RLC mode |
AM RLC |
RBS-205 |
|||||||
|
– Transmission RLC discard |
RBS-206 |
||||||||
|
– CHOICE SDU discard mode |
No Discard |
RBS-207 |
|||||||
|
– MAX_DAT |
15 |
RBS-208 |
|||||||
|
– Transmission window size |
128 |
RBS-209 |
|||||||
|
– Timer_RST |
500 |
RBS-210 |
|||||||
|
– Max_RST |
4 |
RBS-211 |
|||||||
|
– Polling info |
|
RBS-212 |
|||||||
|
– Timer_poll_prohibit |
200 |
RBS-213 |
|||||||
|
– Timer_poll |
200 |
RBS-214 |
|||||||
|
– Poll_PDU |
Not Present |
RBS-215 |
|||||||
|
– Poll_SDU |
1 |
RBS-216 |
|||||||
|
– Last transmission PDU poll |
TRUE |
RBS-217 |
|||||||
|
– Last retransmission PDU poll |
TRUE |
RBS-218 |
|||||||
|
– Poll_Windows |
99 |
RBS-219 |
|||||||
|
– Timer_poll_periodic |
Not Present |
RBS-220 |
|||||||
|
– CHOICE Downlink RLC mode |
AM RLC |
RBS-221 |
|||||||
|
– CHOICE Downlink RLC PDU Size |
Reference to clause 6 Parameter Set |
Rel-5 |
RBS-222 |
||||||
|
– In-sequence delivery |
TRUE |
RBS-223 |
|||||||
|
– Receiving window size |
128 |
RBS-224 |
|||||||
|
– Downlink RLC status info |
RBS-225 |
||||||||
|
– Timer_status_prohibit |
200 |
RBS-226 |
|||||||
|
– Timer_EPC |
Not Present |
RBS-227 |
|||||||
|
– Missing PDU indicator |
TRUE |
RBS-228 |
|||||||
|
– Timer_STATUS_periodic |
Not Present |
RBS-229 |
|||||||
|
– RB mapping info |
|
RBS-230 |
|||||||
|
– Information for each multiplexing option |
2 RBMuxOptions |
RBS-231 |
|||||||
|
– RLC logical channel mapping indicator |
Not Present |
RBS-232 |
|||||||
|
– Number of uplink RLC logical channels |
1 |
RBS-233 |
|||||||
|
– Uplink transport channel type |
DCH |
RBS-234 |
|||||||
|
– UL Transport channel identity |
1 |
RBS-235 |
|||||||
|
– Logical channel identity |
Not Present |
RBS-236 |
|||||||
|
– CHOICE RLC size list |
Configured |
RBS-237 |
|||||||
|
– MAC logical channel priority |
8 |
RBS-238 |
|||||||
|
– Downlink RLC logical channel info |
|
RBS-239 |
|||||||
|
– Number of downlink RLC logical channels |
1 |
RBS-240 |
|||||||
|
– Downlink transport channel type |
DCH |
RBS-241 |
|||||||
|
– DL DCH Transport channel identity |
6 |
RBS-242 |
|||||||
|
– DL DSCH Transport channel identity |
Not Present |
RBS-243 |
|||||||
|
– Logical channel identity |
Not Present |
RBS-244 |
|||||||
|
– RLC logical channel mapping indicator |
Not Present |
RBS-245 |
|||||||
|
– Number of uplink RLC logical channels |
1 |
RBS-246 |
|||||||
|
– Uplink transport channel type |
RACH |
RBS-247 |
|||||||
|
– UL Transport channel identity |
Not Present |
RBS-248 |
|||||||
|
– Logical channel identity |
7 |
RBS-249 |
|||||||
|
– CHOICE RLC size list |
Explicit list |
RBS-250 |
|||||||
|
– RLC size index |
Reference to clause 6 Parameter Set |
RBS-251 |
|||||||
|
– MAC logical channel priority |
8 |
RBS-252 |
|||||||
|
– Downlink RLC logical channel info |
RBS-253 |
||||||||
|
– Number of downlink RLC logical channels |
1 |
RBS-254 |
|||||||
|
– Downlink transport channel type |
FACH |
RBS-255 |
|||||||
|
– DL DCH Transport channel identity |
Not Present |
RBS-256 |
|||||||
|
– DL DSCH Transport channel identity |
Not Present |
RBS-257 |
|||||||
|
– Logical channel identity |
7 |
RBS-258 |
|||||||
|
– RAB information for setup |
A9 |
|
Rel-5 |
RBS-259 |
|||||
|
– RAB info |
(high-speed AM DTCH for PS domain) |
RBS-260 |
|||||||
|
– RAB identity |
0000 0101B The first/ leftmost bit of the bit string contains the most significant bit of the RAB identity. |
RBS-261 |
|||||||
|
– CN domain identity |
PS domain |
RBS-262 |
|||||||
|
– NAS Synchronization Indicator |
Not Present |
RBS-263 |
|||||||
|
– Re-establishment timer |
useT315 |
RBS-264 |
|||||||
|
– RB information to setup |
|
RBS-265 |
|||||||
|
– RB identity |
25 |
RBS-266 |
|||||||
|
– PDCP info |
|
RBS-267 |
|||||||
|
– Support for lossless SRNS relocation |
FALSE |
RBS-268 |
|||||||
|
– Max PDCP SN window size |
Not present |
RBS-269 |
|||||||
|
– PDCP PDU header |
Absent |
RBS-270 |
|||||||
|
– Header compression information |
Not present |
RBS-271 |
|||||||
|
– CHOICE RLC info type |
RLC info |
RBS-272 |
|||||||
|
– CHOICE Uplink RLC mode |
AM RLC |
RBS-273 |
|||||||
|
– Transmission RLC discard |
|
RBS-274 |
|||||||
|
– CHOICE SDU discard mode |
No Discard |
RBS-275 |
|||||||
|
– MAX_DAT |
15 |
RBS-276 |
|||||||
|
– Transmission window size |
128 |
RBS-277 |
|||||||
|
– Timer_RST |
500 |
RBS-278 |
|||||||
|
– Max_RST |
4 |
RBS-279 |
|||||||
|
– Polling info |
|
RBS-280 |
|||||||
|
– Timer_poll_prohibit |
100 |
RBS-281 |
|||||||
|
– Timer_poll |
100 |
RBS-282 |
|||||||
|
– Poll_PDU |
Not Present |
RBS-283 |
|||||||
|
– Poll_SDU |
1 |
RBS-284 |
|||||||
|
– Last transmission PDU poll |
TRUE |
RBS-285 |
|||||||
|
– Last retransmission PDU poll |
TRUE |
RBS-286 |
|||||||
|
– Poll_Windows |
99 |
RBS-287 |
|||||||
|
– Timer_poll_periodic |
Not Present |
RBS-288 |
|||||||
|
– CHOICE Downlink RLC mode |
AM RLC |
RBS-289 |
|||||||
|
– CHOICE Downlink RLC PDU Size |
Reference to clause 6 Parameter Set |
RBS-290 |
|||||||
|
– In-sequence delivery |
TRUE |
RBS-291 |
|||||||
|
– Receiving window size |
768 |
RBS-292 |
|||||||
|
– Downlink RLC status info |
RBS-293 |
||||||||
|
– Timer_status_prohibit |
100 |
RBS-294 |
|||||||
|
– Timer_EPC |
Not Present |
RBS-295 |
|||||||
|
– Missing PDU indicator |
TRUE |
RBS-296 |
|||||||
|
– Timer_STATUS_periodic |
Not Present |
RBS-297 |
|||||||
|
– One sided RLC re-establishment |
FALSE |
RBS-298 |
|||||||
|
– RB mapping info |
RBS-299 |
||||||||
|
– Information for each multiplexing option |
3 RBMuxOptions |
RBS-300 |
|||||||
|
– RLC logical channel mapping indicator |
Not Present |
RBS-301 |
|||||||
|
– Number of uplink RLC logical channels |
1 |
RBS-302 |
|||||||
|
– Uplink transport channel type |
DCH |
RBS-303 |
|||||||
|
– UL Transport channel identity |
1 |
RBS-304 |
|||||||
|
– Logical channel identity |
Not Present |
RBS-305 |
|||||||
|
– CHOICE RLC size list |
Configured |
RBS-306 |
|||||||
|
– MAC logical channel priority |
8 |
RBS-307 |
|||||||
|
– Downlink RLC logical channel info |
RBS-308 |
||||||||
|
– Number of downlink RLC logical channels |
1 |
RBS-309 |
|||||||
|
– Downlink transport channel type |
DCH |
RBS-310 |
|||||||
|
– DL DCH Transport channel identity |
6 |
RBS-311 |
|||||||
|
– DL DSCH Transport channel identity |
Not Present |
RBS-312 |
|||||||
|
– DL HS-DSCH MAC-d flow identity |
Not Present |
RBS-313 |
|||||||
|
– Logical channel identity |
Not Present |
RBS-314 |
|||||||
|
– RLC logical channel mapping indicator |
Not Present |
RBS-315 |
|||||||
|
– Number of uplink RLC logical channels |
1 |
RBS-316 |
|||||||
|
– Uplink transport channel type |
DCH |
RBS-317 |
|||||||
|
– UL Transport channel identity |
1 |
RBS-318 |
|||||||
|
– Logical channel identity |
Not Present |
RBS-319 |
|||||||
|
– CHOICE RLC size list |
Configured |
RBS-320 |
|||||||
|
– MAC logical channel priority |
8 |
RBS-321 |
|||||||
|
– Downlink RLC logical channel info |
RBS-322 |
||||||||
|
– Number of downlink RLC logical channels |
1 |
RBS-323 |
|||||||
|
– Downlink transport channel type |
HS-DSCH |
RBS-324 |
|||||||
|
– DL DCH Transport channel identity |
Not Present |
RBS-325 |
|||||||
|
– DL DSCH Transport channel identity |
Not Present |
RBS-326 |
|||||||
|
– DL HS-DSCH MAC-d flow identity |
0 |
RBS-327 |
|||||||
|
– Logical channel identity |
Not Present |
RBS-328 |
|||||||
|
– RLC logical channel mapping indicator |
Not Present |
RBS-329 |
|||||||
|
– Number of uplink RLC logical channels |
1 |
RBS-330 |
|||||||
|
– Uplink transport channel type |
RACH |
RBS-331 |
|||||||
|
– UL Transport channel identity |
Not Present |
RBS-332 |
|||||||
|
– Logical channel identity |
7 |
RBS-333 |
|||||||
|
– CHOICE RLC size list |
Explicit list |
RBS-334 |
|||||||
|
– RLC size index |
Reference to clause 6 Parameter Set |
RBS-335 |
|||||||
|
– MAC logical channel priority |
8 |
RBS-336 |
|||||||
|
– Downlink RLC logical channel info |
|
RBS-337 |
|||||||
|
– Number of downlink RLC logical channels |
1 |
RBS-338 |
|||||||
|
– Downlink transport channel type |
FACH |
RBS-339 |
|||||||
|
– DL DCH Transport channel identity |
Not Present |
RBS-340 |
|||||||
|
– DL DSCH Transport channel identity |
Not Present |
RBS-341 |
|||||||
|
– Logical channel identity |
7 |
RBS-342 |
|||||||
|
– RAB information for setup |
A10 |
|
Rel-5 |
RBS-343 |
|||||
|
– RAB info |
(high-speed AM DTCH for PS domain) |
RBS-344 |
|||||||
|
– RAB identity |
0000 0101B The first/ leftmost bit of the bit string contains the most significant bit of the RAB identity. |
RBS-345 |
|||||||
|
– CN domain identity |
PS domain |
RBS-346 |
|||||||
|
– NAS Synchronization Indicator |
Not Present |
RBS-347 |
|||||||
|
– Re-establishment timer |
useT315 |
RBS-348 |
|||||||
|
– RB information to setup |
|
RBS-349 |
|||||||
|
– RB identity |
25 |
RBS-350 |
|||||||
|
– PDCP info |
|
RBS-351 |
|||||||
|
– Support for lossless SRNS relocation |
FALSE |
RBS-352 |
|||||||
|
– Max PDCP SN window size |
Not present |
RBS-353 |
|||||||
|
– PDCP PDU header |
Absent |
RBS-354 |
|||||||
|
– Header compression information |
Not present |
RBS-355 |
|||||||
|
– CHOICE RLC info type |
RLC info |
RBS-356 |
|||||||
|
– CHOICE Uplink RLC mode |
AM RLC |
RBS-357 |
|||||||
|
– Transmission RLC discard |
|
RBS-358 |
|||||||
|
– CHOICE SDU discard mode |
No Discard |
RBS-359 |
|||||||
|
– MAX_DAT |
15 |
RBS-360 |
|||||||
|
– Transmission window size |
128 |
RBS-361 |
|||||||
|
– Timer_RST |
500 |
RBS-362 |
|||||||
|
– Max_RST |
4 |
RBS-363 |
|||||||
|
– Polling info |
|
RBS-364 |
|||||||
|
– Timer_poll_prohibit |
100 |
RBS-365 |
|||||||
|
– Timer_poll |
100 |
RBS-366 |
|||||||
|
– Poll_PDU |
Not Present |
RBS-367 |
|||||||
|
– Poll_SDU |
1 |
RBS-368 |
|||||||
|
– Last transmission PDU poll |
TRUE |
RBS-369 |
|||||||
|
– Last retransmission PDU poll |
TRUE |
RBS-370 |
|||||||
|
– Poll_Windows |
99 |
RBS-371 |
|||||||
|
– Timer_poll_periodic |
Not Present |
RBS-372 |
|||||||
|
– CHOICE Downlink RLC mode |
AM RLC |
RBS-373 |
|||||||
|
– CHOICE Downlink RLC PDU Size |
Reference to clause 6 Parameter Set |
RBS-374 |
|||||||
|
– In-sequence delivery |
TRUE |
RBS-375 |
|||||||
|
– Receiving window size |
768 |
RBS-376 |
|||||||
|
– Downlink RLC status info |
|
RBS-377 |
|||||||
|
– Timer_status_prohibit |
100 |
RBS-378 |
|||||||
|
– Timer_EPC |
Not Present |
RBS-379 |
|||||||
|
– Missing PDU indicator |
TRUE |
RBS-380 |
|||||||
|
– Timer_STATUS_periodic |
Not Present |
RBS-381 |
|||||||
|
– One sided RLC re-establishment |
FALSE |
RBS-382 |
|||||||
|
– RB mapping info |
|
RBS-383 |
|||||||
|
– Information for each multiplexing option |
1 RBMuxOption |
RBS-384 |
|||||||
|
– RLC logical channel mapping indicator |
Not present |
RBS-385 |
|||||||
|
– Number of uplink RLC logical channels |
1 |
RBS-386 |
|||||||
|
– Uplink transport channel type |
DCH |
RBS-387 |
|||||||
|
– UL Transport channel identity |
1 |
RBS-388 |
|||||||
|
– Logical channel identity |
Not Present |
RBS-389 |
|||||||
|
– CHOICE RLC size list |
Configured |
RBS-390 |
|||||||
|
– MAC logical channel priority |
8 |
RBS-391 |
|||||||
|
– Downlink RLC logical channel info |
RBS-392 |
||||||||
|
– Number of downlink RLC logical channels |
1 |
RBS-393 |
|||||||
|
– Downlink transport channel type |
HS-DSCH |
RBS-394 |
|||||||
|
– DL DCH Transport channel identity |
Not present |
RBS-395 |
|||||||
|
– DL DSCH Transport channel identity |
Not present |
RBS-396 |
|||||||
|
– DL HS-DSCH MAC-d flow identity |
0 |
RBS-397 |
|||||||
|
– Logical channel identity |
Not Present |
RBS-398 |
|||||||
|
– RAB information for setup |
A11 |
RBS-399 |
|||||||
|
– RAB info |
(AM DTCH for PS domain) |
RBS-400 |
|||||||
|
– RAB identity |
0000 0101B The first/ leftmost bit of the bit string contains the most significant bit of the RAB identity. |
RBS-401 |
|||||||
|
– CN domain identity |
PS domain |
RBS-402 |
|||||||
|
– NAS Synchronization Indicator |
Not Present |
RBS-403 |
|||||||
|
– Re-establishment timer |
useT315 |
RBS-404 |
|||||||
|
– RB information to setup |
RBS-405 |
||||||||
|
– RB identity |
20 |
RBS-406 |
|||||||
|
– PDCP info |
RBS-407 |
||||||||
|
– Support for lossless SRNS relocation |
FALSE |
RBS-408 |
|||||||
|
– Max PDCP SN window size |
Not present |
RBS-409 |
|||||||
|
– PDCP PDU header |
Absent |
RBS-410 |
|||||||
|
– Header compression information |
Not present |
RBS-411 |
|||||||
|
– CHOICE RLC info type |
RLC info |
RBS-412 |
|||||||
|
– CHOICE Uplink RLC mode |
AM RLC |
RBS-413 |
|||||||
|
– Transmission RLC discard |
RBS-414 |
||||||||
|
– CHOICE SDU discard mode |
No Discard |
RBS-415 |
|||||||
|
– MAX_DAT |
15 |
RBS-416 |
|||||||
|
– Transmission window size |
128 |
RBS-417 |
|||||||
|
– Timer_RST |
500 |
RBS-418 |
|||||||
|
– Max_RST |
4 |
RBS-419 |
|||||||
|
– Polling info |
RBS-420 |
||||||||
|
– Timer_poll_prohibit |
200 |
RBS-421 |
|||||||
|
– Timer_poll |
200 |
RBS-422 |
|||||||
|
– Poll_PDU |
Not Present |
RBS-423 |
|||||||
|
– Poll_SDU |
1 |
RBS-424 |
|||||||
|
– Last transmission PDU poll |
TRUE |
RBS-425 |
|||||||
|
– Last retransmission PDU poll |
TRUE |
RBS-426 |
|||||||
|
– Poll_Windows |
99 |
RBS-427 |
|||||||
|
– Timer_poll_periodic |
Not Present |
RBS-428 |
|||||||
|
– CHOICE Downlink RLC mode |
AM RLC |
RBS-429 |
|||||||
|
– CHOICE Downlink RLC PDU Size |
Reference to clause 6 Parameter Set |
Rel-5 |
RBS-430 |
||||||
|
– In-sequence delivery |
TRUE |
|
RBS-431 |
||||||
|
– Receiving window size |
128 |
|
RBS-432 |
||||||
|
– Downlink RLC status info |
|
RBS-433 |
|||||||
|
– Timer_status_prohibit |
200 |
|
RBS-434 |
||||||
|
– Timer_EPC |
Not Present |
|
RBS-435 |
||||||
|
– Missing PDU indicator |
TRUE |
|
RBS-436 |
||||||
|
– Timer_STATUS_periodic |
Not Present |
|
RBS-437 |
||||||
|
– RB mapping info |
|
RBS-438 |
|||||||
|
– Information for each multiplexing option |
2 RBMuxOptions |
|
RBS-439 |
||||||
|
– RLC logical channel mapping indicator |
Not Present |
|
RBS-440 |
||||||
|
– Number of uplink RLC logical channels |
1 |
|
RBS-441 |
||||||
|
– Uplink transport channel type |
DCH |
|
RBS-442 |
||||||
|
– UL Transport channel identity |
4 |
|
RBS-443 |
||||||
|
– Logical channel identity |
Not Present |
|
RBS-444 |
||||||
|
– CHOICE RLC size list |
Configured |
|
RBS-445 |
||||||
|
– MAC logical channel priority |
8 |
|
RBS-446 |
||||||
|
– Downlink RLC logical channel info |
|
|
RBS-447 |
||||||
|
– Number of downlink RLC logical channels |
1 |
|
RBS-448 |
||||||
|
– Downlink transport channel type |
DCH |
|
RBS-449 |
||||||
|
– DL DCH Transport channel identity |
9 |
|
RBS-450 |
||||||
|
– DL DSCH Transport channel identity |
Not Present |
|
RBS-451 |
||||||
|
– Logical channel identity |
Not Present |
|
RBS-452 |
||||||
|
– RLC logical channel mapping indicator |
Not Present |
|
RBS-453 |
||||||
|
– Number of uplink RLC logical channels |
1 |
|
RBS-454 |
||||||
|
– Uplink transport channel type |
RACH |
|
RBS-455 |
||||||
|
– UL Transport channel identity |
Not Present |
|
RBS-456 |
||||||
|
– Logical channel identity |
7 |
|
RBS-457 |
||||||
|
– CHOICE RLC size list |
Explicit list |
|
RBS-458 |
||||||
|
– RLC size index |
Reference to clause 6 Parameter Set |
|
RBS-459 |
||||||
|
– MAC logical channel priority |
8 |
|
RBS-460 |
||||||
|
– Downlink RLC logical channel info |
|
|
RBS-461 |
||||||
|
– Number of downlink RLC logical channels |
1 |
|
RBS-462 |
||||||
|
– Downlink transport channel type |
FACH |
|
RBS-463 |
||||||
|
– DL DCH Transport channel identity |
Not Present |
|
RBS-464 |
||||||
|
– DL DSCH Transport channel identity |
Not Present |
|
RBS-465 |
||||||
|
– Logical channel identity |
7 |
|
RBS-466 |
||||||
|
– RAB information for setup |
A12 |
Rel-6 |
RBS-467 |
||||||
|
A19 |
Rel-7 |
RBS-468 |
|||||||
|
– RAB info |
(high-speed AM DTCH for PS domain) |
RBS-469 |
|||||||
|
– RAB identity |
0000 0101B The first/ leftmost bit of the bit string contains the most significant bit of the RAB identity. |
RBS-470 |
|||||||
|
– CN domain identity |
PS domain |
RBS-471 |
|||||||
|
– NAS Synchronization Indicator |
Not Present |
RBS-472 |
|||||||
|
– Re-establishment timer |
useT315 |
RBS-473 |
|||||||
|
– RB information to setup |
RBS-474 |
||||||||
|
– RB identity |
25 |
RBS-475 |
|||||||
|
– PDCP info |
RBS-476 |
||||||||
|
– Support for lossless SRNS relocation |
FALSE |
RBS-477 |
|||||||
|
– Max PDCP SN window size |
Not present |
RBS-478 |
|||||||
|
– PDCP PDU header |
Absent |
RBS-479 |
|||||||
|
– Header compression information |
Not present |
RBS-480 |
|||||||
|
– CHOICE RLC info type |
RLC info |
RBS-481 |
|||||||
|
– CHOICE Uplink RLC mode |
AM RLC |
RBS-482 |
|||||||
|
– Transmission RLC discard |
RBS-483 |
||||||||
|
– CHOICE SDU discard mode |
No Discard |
RBS-484 |
|||||||
|
– MAX_DAT |
15 |
RBS-485 |
|||||||
|
– Transmission window size |
256 |
RBS-486 |
|||||||
|
– Timer_RST |
500 |
RBS-487 |
|||||||
|
– Max_RST |
4 |
RBS-488 |
|||||||
|
– Polling info |
RBS-489 |
||||||||
|
– Timer_poll_prohibit |
100 |
RBS-490 |
|||||||
|
– Timer_poll |
100 |
RBS-491 |
|||||||
|
– Poll_PDU |
Not Present |
RBS-492 |
|||||||
|
– Poll_SDU |
1 |
RBS-493 |
|||||||
|
– Last transmission PDU poll |
TRUE |
RBS-494 |
|||||||
|
– Last retransmission PDU poll |
TRUE |
RBS-495 |
|||||||
|
– Poll_Windows |
99 |
RBS-496 |
|||||||
|
– Timer_poll_periodic |
Not Present |
RBS-497 |
|||||||
|
– CHOICE Downlink RLC mode |
AM RLC |
RBS-498 |
|||||||
|
– CHOICE Downlink RLC PDU Size |
Reference to clause 6 Parameter Set |
RBS-499 |
|||||||
|
– In-sequence delivery |
TRUE |
RBS-500 |
|||||||
|
– Receiving window size |
768 |
RBS-501 |
|||||||
|
– Downlink RLC status info |
RBS-502 |
||||||||
|
– Timer_status_prohibit |
100 |
RBS-503 |
|||||||
|
– Timer_EPC |
Not Present |
RBS-504 |
|||||||
|
– Missing PDU indicator |
TRUE |
RBS-505 |
|||||||
|
– Timer_STATUS_periodic |
Not Present |
RBS-506 |
|||||||
|
– One sided RLC re-establishment |
FALSE |
RBS-507 |
|||||||
|
– RB mapping info |
RBS-508 |
||||||||
|
– Information for each multiplexing option |
3 RBMuxOptions |
RBS-509 |
|||||||
|
– RLC logical channel mapping indicator |
Not Present |
RBS-510 |
|||||||
|
– Number of uplink RLC logical channels |
1 |
RBS-511 |
|||||||
|
– Uplink transport channel type |
DCH |
RBS-512 |
|||||||
|
– UL Transport channel identity |
1 |
RBS-513 |
|||||||
|
– Logical channel identity |
Not Present |
RBS-514 |
|||||||
|
– CHOICE RLC size list |
Configured |
RBS-515 |
|||||||
|
– MAC logical channel priority |
8 |
RBS-516 |
|||||||
|
– Downlink RLC logical channel info |
RBS-517 |
||||||||
|
– Number of downlink RLC logical channels |
1 |
RBS-518 |
|||||||
|
– Downlink transport channel type |
DCH |
RBS-519 |
|||||||
|
– DL DCH Transport channel identity |
6 |
RBS-520 |
|||||||
|
– DL DSCH Transport channel identity |
Not Present |
RBS-521 |
|||||||
|
– DL HS-DSCH MAC-d flow identity |
Not Present |
RBS-522 |
|||||||
|
– Logical channel identity |
Not Present |
RBS-523 |
|||||||
|
– RLC logical channel mapping indicator |
Not Present |
RBS-524 |
|||||||
|
– Number of uplink RLC logical channels |
1 |
RBS-525 |
|||||||
|
– Uplink transport channel type |
E-DCH |
RBS-526 |
|||||||
|
– Logical channel identity |
7 |
RBS-527 |
|||||||
|
– E-DCH MAC-d flow identity |
2 |
RBS-528 |
|||||||
|
– CHOICE RLC PDU size |
MAC-I-FIXED |
Fixed size |
Rel-8 |
RBS-529 |
|||||
|
– DDI |
5 |
RBS-530 |
|||||||
|
– RLC PDU size list |
1 RLC PDU size |
RBS-531 |
|||||||
|
– RLC PDU size |
336 bits |
RBS-532 |
|||||||
|
– CHOICE RLC PDU size |
MAC-I-FLEX |
Flexible size |
Rel-8 |
RBS-533 |
|||||
|
– Length indicator size |
15 bit |
RBS-534 |
|||||||
|
– Minimum UL RLC PDU size |
See clause 6.10 |
RBS-535 |
|||||||
|
– Largest UL RLC PDU size |
See clause 6.10 |
RBS-536 |
|||||||
|
– Include in scheduling info |
TRUE |
RBS-537 |
|||||||
|
– MAC logical channel priority |
8 |
RBS-538 |
|||||||
|
– Downlink RLC logical channel info |
RBS-539 |
||||||||
|
– Number of downlink RLC logical channels |
1 |
RBS-540 |
|||||||
|
– Downlink transport channel type |
HS-DSCH |
RBS-541 |
|||||||
|
– DL DCH Transport channel identity |
Not Present |
RBS-542 |
|||||||
|
– DL DSCH Transport channel identity |
Not Present |
RBS-543 |
|||||||
|
– DL HS-DSCH MAC-d flow identity |
0 |
RBS-544 |
|||||||
|
– Logical channel identity |
Not Present |
RBS-545 |
|||||||
|
– RLC logical channel mapping indicator |
Not Present |
RBS-546 |
|||||||
|
– Number of uplink RLC logical channels |
1 |
RBS-547 |
|||||||
|
– Uplink transport channel type |
RACH |
RBS-548 |
|||||||
|
– UL Transport channel identity |
Not Present |
RBS-549 |
|||||||
|
– Logical channel identity |
7 |
RBS-550 |
|||||||
|
– CHOICE RLC size list |
Explicit list |
RBS-551 |
|||||||
|
– RLC size index |
Reference to clause 6 Parameter Set |
RBS-552 |
|||||||
|
– MAC logical channel priority |
8 |
RBS-553 |
|||||||
|
– Downlink RLC logical channel info |
RBS-554 |
||||||||
|
– Number of downlink RLC logical channels |
1 |
RBS-555 |
|||||||
|
– Downlink transport channel type |
FACH |
RBS-556 |
|||||||
|
– DL DCH Transport channel identity |
Not Present |
RBS-557 |
|||||||
|
– DL DSCH Transport channel identity |
Not Present |
RBS-558 |
|||||||
|
– RAB information for setup |
A13, A14, A15, A16 |
Rel-6 |
RBS-559 |
||||||
|
, A19a, A19b |
Rel-7 |
RBS-560 |
|||||||
|
– RAB info |
(high-speed AM DTCH for PS domain) |
RBS-561 |
|||||||
|
– RAB identity |
0000 0101B The first/ leftmost bit of the bit string contains the most significant bit of the RAB identity. |
RBS-562 |
|||||||
|
– CN domain identity |
PS domain |
RBS-563 |
|||||||
|
– NAS Synchronization Indicator |
Not Present |
RBS-564 |
|||||||
|
– Re-establishment timer |
useT315 |
RBS-565 |
|||||||
|
– RB information to setup |
RBS-566 |
||||||||
|
– RB identity |
25 |
RBS-567 |
|||||||
|
– PDCP info |
RBS-568 |
||||||||
|
– Support for lossless SRNS relocation |
FALSE |
RBS-569 |
|||||||
|
– Max PDCP SN window size |
Not present |
RBS-570 |
|||||||
|
– PDCP PDU header |
Absent |
RBS-571 |
|||||||
|
– Header compression information |
Not present |
RBS-572 |
|||||||
|
– CHOICE RLC info type |
RLC info |
RBS-573 |
|||||||
|
– CHOICE Uplink RLC mode |
AM RLC |
RBS-574 |
|||||||
|
– Transmission RLC discard |
RBS-575 |
||||||||
|
– CHOICE SDU discard mode |
No Discard |
RBS-576 |
|||||||
|
– MAX_DAT |
15 |
RBS-577 |
|||||||
|
– Transmission window size |
256 |
RBS-578 |
|||||||
|
– Timer_RST |
500 |
RBS-579 |
|||||||
|
– Max_RST |
4 |
RBS-580 |
|||||||
|
– Polling info |
RBS-581 |
||||||||
|
– Timer_poll_prohibit |
100 |
RBS-582 |
|||||||
|
– Timer_poll |
100 |
RBS-583 |
|||||||
|
– Poll_PDU |
Not Present |
RBS-584 |
|||||||
|
– Poll_SDU |
1 |
RBS-585 |
|||||||
|
– Last transmission PDU poll |
TRUE |
RBS-586 |
|||||||
|
– Last retransmission PDU poll |
TRUE |
RBS-587 |
|||||||
|
– Poll_Windows |
99 |
RBS-588 |
|||||||
|
– Timer_poll_periodic |
Not Present |
RBS-589 |
|||||||
|
– CHOICE Downlink RLC mode |
AM RLC |
RBS-590 |
|||||||
|
– CHOICE Downlink RLC PDU Size |
Reference to clause 6 Parameter Set |
RBS-591 |
|||||||
|
– In-sequence delivery |
TRUE |
RBS-592 |
|||||||
|
– Receiving window size |
768 |
RBS-593 |
|||||||
|
– Downlink RLC status info |
RBS-594 |
||||||||
|
– Timer_status_prohibit |
100 |
RBS-595 |
|||||||
|
– Timer_EPC |
Not Present |
RBS-596 |
|||||||
|
– Missing PDU indicator |
TRUE |
RBS-597 |
|||||||
|
– Timer_STATUS_periodic |
Not Present |
RBS-598 |
|||||||
|
– One sided RLC re-establishment |
FALSE |
RBS-599 |
|||||||
|
– RB mapping info |
RBS-600 |
||||||||
|
– Information for each multiplexing option |
1 RBMuxOption |
RBS-601 |
|||||||
|
– RLC logical channel mapping indicator |
Not Present |
RBS-602 |
|||||||
|
– Number of uplink RLC logical channels |
1 |
RBS-603 |
|||||||
|
– Uplink transport channel type |
E-DCH |
RBS-604 |
|||||||
|
– Logical channel identity |
7 |
RBS-605 |
|||||||
|
– E-DCH MAC-d flow identity |
2 |
RBS-606 |
|||||||
|
– CHOICE RLC PDU size |
MAC-I-FIXED |
Fixed size |
Rel-8 |
RBS-607 |
|||||
|
– DDI |
5 |
RBS-608 |
|||||||
|
– RLC PDU size list |
1 RLC PDU size |
RBS-609 |
|||||||
|
– RLC PDU size |
336 bits |
RBS-610 |
|||||||
|
– CHOICE RLC PDU size |
MAC-I-FLEX |
Flexible size |
Rel-8 |
RBS-611 |
|||||
|
– Length indicator size |
– 15 bit |
RBS-612 |
|||||||
|
– Minimum UL RLC PDU size |
See clause 6.10 |
RBS-613 |
|||||||
|
– Largest UL RLC PDU size |
See clause 6.10 |
RBS-614 |
|||||||
|
– Include in scheduling info |
TRUE |
RBS-615 |
|||||||
|
– MAC logical channel priority |
8 |
RBS-616 |
|||||||
|
– Downlink RLC logical channel info |
RBS-617 |
||||||||
|
– Number of downlink RLC logical channels |
1 |
RBS-618 |
|||||||
|
– Downlink transport channel type |
HS-DSCH |
RBS-619 |
|||||||
|
– DL DCH Transport channel identity |
Not present |
RBS-620 |
|||||||
|
– DL DSCH Transport channel identity |
Not present |
RBS-621 |
|||||||
|
– DL HS-DSCH MAC-d flow identity |
0 |
RBS-622 |
|||||||
|
– Logical channel identity |
Not Present |
RBS-623 |
|||||||
|
– RAB information for setup |
A15 |
Rel-6 |
RBS-624 |
||||||
|
– RAB info |
(second high-speed AM DTCH for PS domain) |
RBS-625 |
|||||||
|
– RAB identity |
0000 0110B The first/ leftmost bit of the bit string contains the most significant bit of the RAB identity. |
RBS-626 |
|||||||
|
– CN domain identity |
PS domain |
RBS-627 |
|||||||
|
– NAS Synchronization Indicator |
Not Present |
RBS-628 |
|||||||
|
– Re-establishment timer |
useT315 |
RBS-629 |
|||||||
|
– RB information to setup |
RBS-630 |
||||||||
|
– RB identity |
17 |
RBS-631 |
|||||||
|
– PDCP info |
RBS-632 |
||||||||
|
– Support for lossless SRNS relocation |
FALSE |
RBS-633 |
|||||||
|
– Max PDCP SN window size |
Not present |
RBS-634 |
|||||||
|
– PDCP PDU header |
Absent |
RBS-635 |
|||||||
|
– Header compression information |
Not present |
RBS-636 |
|||||||
|
– CHOICE RLC info type |
RLC info |
RBS-637 |
|||||||
|
– CHOICE Uplink RLC mode |
AM RLC |
RBS-638 |
|||||||
|
– Transmission RLC discard |
RBS-639 |
||||||||
|
– CHOICE SDU discard mode |
No Discard |
RBS-640 |
|||||||
|
– MAX_DAT |
15 |
RBS-641 |
|||||||
|
– Transmission window size |
256 |
RBS-642 |
|||||||
|
– Timer_RST |
500 |
RBS-643 |
|||||||
|
– Max_RST |
4 |
RBS-644 |
|||||||
|
– Polling info |
RBS-645 |
||||||||
|
– Timer_poll_prohibit |
100 |
RBS-646 |
|||||||
|
– Timer_poll |
100 |
RBS-647 |
|||||||
|
– Poll_PDU |
Not Present |
RBS-648 |
|||||||
|
– Poll_SDU |
1 |
RBS-649 |
|||||||
|
– Last transmission PDU poll |
TRUE |
RBS-650 |
|||||||
|
– Last retransmission PDU poll |
TRUE |
RBS-651 |
|||||||
|
– Poll_Windows |
99 |
RBS-652 |
|||||||
|
– Timer_poll_periodic |
Not Present |
RBS-653 |
|||||||
|
– CHOICE Downlink RLC mode |
AM RLC |
RBS-654 |
|||||||
|
– CHOICE Downlink RLC PDU Size |
Reference to clause 6 Parameter Set |
RBS-655 |
|||||||
|
– In-sequence delivery |
TRUE |
RBS-656 |
|||||||
|
– Receiving window size |
768 |
RBS-657 |
|||||||
|
– Downlink RLC status info |
RBS-658 |
||||||||
|
– Timer_status_prohibit |
100 |
RBS-659 |
|||||||
|
– Timer_EPC |
Not Present |
RBS-660 |
|||||||
|
– Missing PDU indicator |
TRUE |
RBS-661 |
|||||||
|
– Timer_STATUS_periodic |
Not Present |
RBS-662 |
|||||||
|
– One sided RLC re-establishment |
FALSE |
RBS-663 |
|||||||
|
– RB mapping info |
RBS-664 |
||||||||
|
– Information for each multiplexing option |
1 RBMuxOption |
RBS-665 |
|||||||
|
– RLC logical channel mapping indicator |
Not Present |
RBS-666 |
|||||||
|
– Number of uplink RLC logical channels |
1 |
RBS-667 |
|||||||
|
– Uplink transport channel type |
E-DCH |
RBS-668 |
|||||||
|
– Logical channel identity |
8 |
RBS-669 |
|||||||
|
– E-DCH MAC-d flow identity |
3 |
RBS-670 |
|||||||
|
– CHOICE RLC PDU size |
MAC-I-FIXED |
Fixed size |
Rel-8 |
RBS-671 |
|||||
|
– DDI |
6 |
RBS-672 |
|||||||
|
– RLC PDU size list |
1 RLC PDU size |
RBS-673 |
|||||||
|
– RLC PDU size |
336 bits |
RBS-674 |
|||||||
|
– CHOICE RLC PDU size |
MAC-I-FLEX |
Flexible size |
Rel-8 |
RBS-675 |
|||||
|
– Length indicator size |
– 15 bit |
RBS-676 |
|||||||
|
– Minimum UL RLC PDU size |
See clause 6.10 |
RBS-677 |
|||||||
|
– Largest UL RLC PDU size |
See clause 6.10 |
RBS-678 |
|||||||
|
– Include in scheduling info |
TRUE |
RBS-679 |
|||||||
|
– MAC logical channel priority |
8 |
RBS-680 |
|||||||
|
– Downlink RLC logical channel info |
RBS-681 |
||||||||
|
– Number of downlink RLC logical channels |
1 |
RBS-682 |
|||||||
|
– Downlink transport channel type |
HS-DSCH |
RBS-683 |
|||||||
|
– DL DCH Transport channel identity |
Not present |
RBS-684 |
|||||||
|
– DL DSCH Transport channel identity |
Not present |
RBS-685 |
|||||||
|
– DL HS-DSCH MAC-d flow identity |
2 |
RBS-686 |
|||||||
|
– Logical channel identity |
Not Present |
RBS-687 |
|||||||
|
– RAB information for setup |
A16 , A19b |
Rel-6 Rel-7 |
RBS-688 |
||||||
|
– RAB info |
(Conversational UM DTCH for PS domain) |
RBS-689 |
|||||||
|
– RAB identity |
0000 0110B The first/ leftmost bit of the bit string contains the most significant bit of the RAB identity. |
RBS-690 |
|||||||
|
– CN domain identity |
PS domain |
RBS-691 |
|||||||
|
– NAS Synchronization Indicator |
Not Present |
RBS-692 |
|||||||
|
– Re-establishment timer |
useT314 |
RBS-693 |
|||||||
|
– RB information to setup |
RBS-694 |
||||||||
|
– RB identity |
27 |
RBS-695 |
|||||||
|
– PDCP info |
RBS-696 |
||||||||
|
– Support for lossless SRNS relocation |
FALSE |
RBS-697 |
|||||||
|
– Max PDCP SN window size |
Not present |
RBS-698 |
|||||||
|
– PDCP PDU header |
Absent |
RBS-699 |
|||||||
|
– Header compression information |
Not present |
RBS-700 |
|||||||
|
– CHOICE RLC info type |
RLC info |
RBS-701 |
|||||||
|
– CHOICE Uplink RLC mode |
UM RLC |
RBS-702 |
|||||||
|
– Transmission RLC discard |
Not present |
RBS-703 |
|||||||
|
– CHOICE Downlink RLC mode |
UM RLC |
RBS-704 |
|||||||
|
– DL UM RLC LI size |
7 |
RBS-705 |
|||||||
|
– DL Reception Window Size |
32 |
RBS-706 |
|||||||
|
– One sided RLC re-establishment |
FALSE |
RBS-707 |
|||||||
|
– Alternative E-bit interpretation |
Not present |
RBS-708 |
|||||||
|
– RB mapping info |
RBS-709 |
||||||||
|
– Information for each multiplexing option |
1 RBMuxOption |
RBS-710 |
|||||||
|
– RLC logical channel mapping indicator |
Not Present |
RBS-711 |
|||||||
|
– Number of uplink RLC logical channels |
1 |
RBS-712 |
|||||||
|
– Uplink transport channel type |
E-DCH |
RBS-713 |
|||||||
|
– Logical channel identity |
9 |
RBS-714 |
|||||||
|
– E-DCH MAC-d flow identity |
4 |
RBS-715 |
|||||||
|
– CHOICE RLC PDU size |
MAC-I-FIXED |
Fixed size |
Rel-8 |
RBS-716 |
|||||
|
– DDI |
7 |
RBS-717 |
|||||||
|
– RLC PDU size list |
12 RLC PDU sizes |
RBS-718 |
|||||||
|
– RLC PDU size |
96 bits |
RBS-719 |
|||||||
|
– RLC PDU size |
112 bits |
RBS-720 |
|||||||
|
– RLC PDU size |
144 bits |
RBS-721 |
|||||||
|
– RLC PDU size |
160 bits |
RBS-722 |
|||||||
|
– RLC PDU size |
176 bits |
RBS-723 |
|||||||
|
– RLC PDU size |
192 bits |
RBS-724 |
|||||||
|
– RLC PDU size |
208 bits |
RBS-725 |
|||||||
|
– RLC PDU size |
224 bits |
RBS-726 |
|||||||
|
– RLC PDU size |
288 bits |
RBS-727 |
|||||||
|
– RLC PDU size |
296 bits |
RBS-728 |
|||||||
|
– RLC PDU size |
312 bits |
RBS-729 |
|||||||
|
– RLC PDU size |
336 bits |
RBS-730 |
|||||||
|
– CHOICE RLC PDU size |
MAC-I-FLEX |
Flexible size |
Rel-8 |
RBS-731 |
|||||
|
– Length indicator size |
Not present |
RBS-732 |
|||||||
|
– Minimum UL RLC PDU size |
See clause 6.10 |
RBS-733 |
|||||||
|
– Largest UL RLC PDU size |
See clause 6.10 |
RBS-734 |
|||||||
|
– Include in scheduling info |
TRUE |
RBS-735 |
|||||||
|
– MAC logical channel priority |
8 |
RBS-736 |
|||||||
|
– Downlink RLC logical channel info |
RBS-737 |
||||||||
|
– Number of downlink RLC logical channels |
1 |
RBS-738 |
|||||||
|
– Downlink transport channel type |
HS-DSCH |
RBS-739 |
|||||||
|
– DL DCH Transport channel identity |
Not present |
RBS-740 |
|||||||
|
– DL DSCH Transport channel identity |
Not present |
RBS-741 |
|||||||
|
– DL HS-DSCH MAC-d flow identity |
3 |
RBS-742 |
|||||||
|
– Logical channel identity |
Not Present |
RBS-743 |
|||||||
|
– RAB information for setup |
A17, A17a |
Rel-7 |
RBS-744 |
||||||
|
A25a, A28 |
Rel-8 |
RBS-745 |
|||||||
|
– RAB info |
(high-speed AM DTCH for PS domain) |
RBS-746 |
|||||||
|
– RAB identity |
0000 0101B The first/ leftmost bit of the bit string contains the most significant bit of the RAB identity. |
RBS-747 |
|||||||
|
– CN domain identity |
PS domain |
RBS-748 |
|||||||
|
– NAS Synchronization Indicator |
Not Present |
RBS-749 |
|||||||
|
– Re-establishment timer |
useT315 |
RBS-750 |
|||||||
|
– RB information to setup |
RBS-751 |
||||||||
|
– RB identity |
25 |
RBS-752 |
|||||||
|
– PDCP info |
RBS-753 |
||||||||
|
– Support for lossless SRNS relocation |
FALSE |
RBS-754 |
|||||||
|
– Max PDCP SN window size |
Not present |
RBS-755 |
|||||||
|
– PDCP PDU header |
Absent |
RBS-756 |
|||||||
|
– Header compression information |
Not present |
RBS-757 |
|||||||
|
– CHOICE RLC info type |
RLC info |
RBS-758 |
|||||||
|
– CHOICE Uplink RLC mode |
AM RLC |
RBS-759 |
|||||||
|
– Transmission RLC discard |
RBS-760 |
||||||||
|
– CHOICE SDU discard mode |
No Discard |
RBS-761 |
|||||||
|
– MAX_DAT |
15 |
RBS-762 |
|||||||
|
– Transmission window size |
128 |
RBS-763 |
|||||||
|
– Timer_RST |
500 |
RBS-764 |
|||||||
|
– Max_RST |
4 |
RBS-765 |
|||||||
|
– Polling info |
RBS-766 |
||||||||
|
– Timer_poll_prohibit |
100 |
RBS-767 |
|||||||
|
– Timer_poll |
100 |
RBS-768 |
|||||||
|
– Poll_PDU |
Not Present |
RBS-769 |
|||||||
|
– Poll_SDU |
1 |
RBS-770 |
|||||||
|
– Last transmission PDU poll |
TRUE |
RBS-771 |
|||||||
|
– Last retransmission PDU poll |
TRUE |
RBS-772 |
|||||||
|
– Poll_Windows |
99 |
RBS-773 |
|||||||
|
– Timer_poll_periodic |
Not Present |
RBS-774 |
|||||||
|
– CHOICE Downlink RLC mode |
AM RLC |
RBS-775 |
|||||||
|
– CHOICE Downlink RLC PDU Size |
Reference to clause 6 Parameter Set |
RBS-776 |
|||||||
|
– Length indicator size |
This IE is present and set to “7” if Downlink RLC PDU Size is set to “Flexible” |
RBS-777 |
|||||||
|
– In-sequence delivery |
TRUE |
RBS-778 |
|||||||
|
– Receiving window size |
768 |
RBS-779 |
|||||||
|
– Downlink RLC status info |
RBS-780 |
||||||||
|
– Timer_status_prohibit |
100 |
RBS-781 |
|||||||
|
– Timer_EPC |
Not Present |
RBS-782 |
|||||||
|
– Missing PDU indicator |
TRUE |
RBS-783 |
|||||||
|
– Timer_STATUS_periodic |
Not Present |
RBS-784 |
|||||||
|
– One sided RLC re-establishment |
FALSE |
RBS-785 |
|||||||
|
– Alternative E-bit interpretation |
Not present |
RBS-786 |
|||||||
|
– Use special value of HE field |
TRUE |
RBS-787 |
|||||||
|
– RB mapping info |
RBS-788 |
||||||||
|
– Information for each multiplexing option |
1 RBMuxOption |
RBS-789 |
|||||||
|
– RLC logical channel mapping indicator |
Not present |
RBS-790 |
|||||||
|
– Number of uplink RLC logical channels |
1 |
RBS-791 |
|||||||
|
– Uplink transport channel type |
DCH |
RBS-792 |
|||||||
|
– UL Transport channel identity |
1 |
RBS-793 |
|||||||
|
– Logical channel identity |
Not Present |
RBS-794 |
|||||||
|
– CHOICE RLC size list |
Configured |
RBS-795 |
|||||||
|
– MAC logical channel priority |
8 |
RBS-796 |
|||||||
|
– Downlink RLC logical channel info |
RBS-797 |
||||||||
|
– Number of downlink RLC logical channels |
1 |
RBS-798 |
|||||||
|
– Downlink transport channel type |
HS-DSCH |
RBS-799 |
|||||||
|
– DL DCH Transport channel identity |
Not present |
RBS-800 |
|||||||
|
– DL DSCH Transport channel identity |
Not present |
RBS-801 |
|||||||
|
– CHOICE DL MAC header type |
MAC-ehs |
RBS-802 |
|||||||
|
– DL HS-DSCH MAC-ehs Queue Id |
0 |
RBS-803 |
|||||||
|
– Logical channel identity |
7 |
RBS-804 |
|||||||
|
– RAB information for setup |
A17b, A17c,A17d, A17e, A17f,A28a |
Rel-7 |
RBS-805 |
||||||
|
– RAB info |
(high-speed AM DTCH for PS domain) |
RBS-806 |
|||||||
|
– RAB identity |
0000 0101B The first/ leftmost bit of the bit string contains the most significant bit of the RAB identity. |
RBS-807 |
|||||||
|
– CN domain identity |
PS domain |
RBS-808 |
|||||||
|
– NAS Synchronization Indicator |
Not Present |
RBS-809 |
|||||||
|
– Re-establishment timer |
useT315 |
RBS-810 |
|||||||
|
– RB information to setup |
RBS-811 |
||||||||
|
– RB identity |
25 |
RBS-812 |
|||||||
|
– PDCP info |
RBS-813 |
||||||||
|
– Support for lossless SRNS relocation |
FALSE |
RBS-814 |
|||||||
|
– Max PDCP SN window size |
Not present |
RBS-815 |
|||||||
|
– PDCP PDU header |
Absent |
RBS-816 |
|||||||
|
– Header compression information |
Not present |
RBS-817 |
|||||||
|
– CHOICE RLC info type |
RLC info |
RBS-818 |
|||||||
|
– CHOICE Uplink RLC mode |
AM RLC |
RBS-819 |
|||||||
|
– Transmission RLC discard |
RBS-820 |
||||||||
|
– CHOICE SDU discard mode |
No Discard |
RBS-821 |
|||||||
|
– MAX_DAT |
15 |
RBS-822 |
|||||||
|
– Transmission window size |
256 |
RBS-823 |
|||||||
|
– Timer_RST |
500 |
RBS-824 |
|||||||
|
– Max_RST |
4 |
RBS-825 |
|||||||
|
– Polling info |
RBS-826 |
||||||||
|
– Timer_poll_prohibit |
100 |
RBS-827 |
|||||||
|
– Timer_poll |
100 |
RBS-828 |
|||||||
|
– Poll_PDU |
Not Present |
RBS-829 |
|||||||
|
– Poll_SDU |
1 |
RBS-830 |
|||||||
|
– Last transmission PDU poll |
TRUE |
RBS-831 |
|||||||
|
– Last retransmission PDU poll |
TRUE |
RBS-832 |
|||||||
|
– Poll_Windows |
99 |
RBS-833 |
|||||||
|
– Timer_poll_periodic |
Not Present |
RBS-834 |
|||||||
|
– CHOICE Downlink RLC mode |
AM RLC |
RBS-835 |
|||||||
|
– CHOICE Downlink RLC PDU Size |
Reference to clause 6 Parameter Set |
RBS-836 |
|||||||
|
– Length indicator size |
This IE is present and set to “7” if Downlink RLC PDU Size is set to “Flexible” |
RBS-837 |
|||||||
|
– In-sequence delivery |
TRUE |
RBS-838 |
|||||||
|
– Receiving window size |
768 |
RBS-839 |
|||||||
|
– Downlink RLC status info |
RBS-840 |
||||||||
|
– Timer_status_prohibit |
100 |
RBS-841 |
|||||||
|
– Timer_EPC |
Not Present |
RBS-842 |
|||||||
|
– Missing PDU indicator |
TRUE |
RBS-843 |
|||||||
|
– Timer_STATUS_periodic |
Not Present |
RBS-844 |
|||||||
|
– One sided RLC re-establishment |
FALSE |
RBS-845 |
|||||||
|
– Alternative E-bit interpretation |
Not present |
RBS-846 |
|||||||
|
– Use special value of HE field |
TRUE |
RBS-847 |
|||||||
|
– RB mapping info |
RBS-848 |
||||||||
|
– Information for each multiplexing option |
1 RBMuxOption |
RBS-849 |
|||||||
|
– RLC logical channel mapping indicator |
Not Present |
RBS-850 |
|||||||
|
– Number of uplink RLC logical channels |
1 |
RBS-851 |
|||||||
|
– Uplink transport channel type |
E-DCH |
RBS-852 |
|||||||
|
– Logical channel identity |
7 |
RBS-853 |
|||||||
|
– E-DCH MAC-d flow identity |
2 |
RBS-854 |
|||||||
|
– CHOICE RLC PDU size |
MAC-I-FIXED |
Fixed size |
Rel-8 |
RBS-855 |
|||||
|
– DDI |
5 |
RBS-856 |
|||||||
|
– RLC PDU size list |
1 RLC PDU size |
RBS-857 |
|||||||
|
– RLC PDU size |
336 bits |
RBS-858 |
|||||||
|
– CHOICE RLC PDU size |
MAC-I-FLEX |
Flexible size |
Rel-8 |
RBS-859 |
|||||
|
– Length indicator size |
– 15 bit |
RBS-860 |
|||||||
|
– Minimum UL RLC PDU size |
See clause 6.10 |
RBS-861 |
|||||||
|
– Largest UL RLC PDU size |
See clause 6.10 |
RBS-862 |
|||||||
|
– Include in scheduling info |
TRUE |
RBS-863 |
|||||||
|
– MAC logical channel priority |
8 |
RBS-864 |
|||||||
|
– Downlink RLC logical channel info |
RBS-865 |
||||||||
|
– Number of downlink RLC logical channels |
1 |
RBS-866 |
|||||||
|
– Downlink transport channel type |
HS-DSCH |
RBS-867 |
|||||||
|
– DL DCH Transport channel identity |
Not present |
RBS-868 |
|||||||
|
– DL DSCH Transport channel identity |
Not present |
RBS-869 |
|||||||
|
– CHOICE DL MAC header type |
MAC-ehs |
RBS-870 |
|||||||
|
– DL HS-DSCH MAC-ehs Queue Id |
0 |
RBS-871 |
|||||||
|
– Logical channel identity |
7 |
RBS-872 |
|||||||
|
– RAB information for setup |
A18 |
Rel-7 |
RBS-873 |
||||||
|
– RAB info |
(high-speed UM DTCH for PS domain) |
RBS-874 |
|||||||
|
– RAB identity |
0000 0101B The first/ leftmost bit of the bit string contains the most significant bit of the RAB identity. |
RBS-875 |
|||||||
|
– CN domain identity |
PS domain |
RBS-876 |
|||||||
|
– NAS Synchronization Indicator |
Not Present |
RBS-877 |
|||||||
|
– Re-establishment timer |
useT315 |
RBS-878 |
|||||||
|
– RB information to setup |
RBS-879 |
||||||||
|
– RB identity |
25 |
RBS-880 |
|||||||
|
– PDCP info |
RBS-881 |
||||||||
|
– Support for lossless SRNS relocation |
FALSE |
RBS-882 |
|||||||
|
– Max PDCP SN window size |
Not present |
RBS-883 |
|||||||
|
– PDCP PDU header |
Absent |
RBS-884 |
|||||||
|
– Header compression information |
Not present |
RBS-885 |
|||||||
|
– CHOICE RLC info type |
RLC info |
RBS-886 |
|||||||
|
– CHOICE Uplink RLC mode |
UM RLC |
RBS-887 |
|||||||
|
– Transmission RLC discard |
Not present |
RBS-888 |
|||||||
|
– CHOICE Downlink RLC mode |
UM RLC |
RBS-889 |
|||||||
|
– DL UM RLC LI size |
7 |
RBS-890 |
|||||||
|
– DL Reception Window Size |
Not present |
RBS-891 |
|||||||
|
– One sided RLC re-establishment |
FALSE |
RBS-892 |
|||||||
|
– Alternative E-bit interpretation |
TRUE |
RBS-893 |
|||||||
|
– Use special value of HE field |
Not present |
RBS-894 |
|||||||
|
– RB mapping info |
RBS-895 |
||||||||
|
– Information for each multiplexing option |
1 RBMuxOption |
RBS-896 |
|||||||
|
– RLC logical channel mapping indicator |
Not present |
RBS-897 |
|||||||
|
– Number of uplink RLC logical channels |
1 |
RBS-898 |
|||||||
|
– Uplink transport channel type |
DCH |
RBS-899 |
|||||||
|
– UL Transport channel identity |
1 |
RBS-900 |
|||||||
|
– Logical channel identity |
Not Present |
RBS-901 |
|||||||
|
– CHOICE RLC size list |
Configured |
RBS-902 |
|||||||
|
– MAC logical channel priority |
8 |
RBS-903 |
|||||||
|
– Downlink RLC logical channel info |
RBS-904 |
||||||||
|
– Number of downlink RLC logical channels |
1 |
RBS-905 |
|||||||
|
– Downlink transport channel type |
HS-DSCH |
RBS-906 |
|||||||
|
– DL DCH Transport channel identity |
Not present |
RBS-907 |
|||||||
|
– DL DSCH Transport channel identity |
Not present |
RBS-908 |
|||||||
|
– CHOICE DL MAC header type |
MAC-ehs |
RBS-909 |
|||||||
|
– DL HS-DSCH MAC-ehs Queue Id |
0 |
RBS-910 |
|||||||
|
– Logical channel identity |
7 |
RBS-911 |
|||||||
|
– RAB information for setup |
,A20, A21 |
Rel-7 |
RBS-912 |
||||||
|
– RAB info |
(high-speed AM DTCH for PS domain) |
RBS-913 |
|||||||
|
– RAB identity |
0000 0101B The first/ leftmost bit of the bit string contains the most significant bit of the RAB identity. |
RBS-914 |
|||||||
|
– CN domain identity |
PS domain |
RBS-915 |
|||||||
|
– NAS Synchronization Indicator |
Not Present |
RBS-916 |
|||||||
|
– Re-establishment timer |
useT315 |
RBS-917 |
|||||||
|
– RB information to setup |
RBS-918 |
||||||||
|
– RB identity |
25 |
RBS-919 |
|||||||
|
– PDCP info |
RBS-920 |
||||||||
|
– Support for lossless SRNS relocation |
FALSE |
RBS-921 |
|||||||
|
– Max PDCP SN window size |
Not present |
RBS-922 |
|||||||
|
– PDCP PDU header |
Absent |
RBS-923 |
|||||||
|
– Header compression information |
Not present |
RBS-924 |
|||||||
|
– CHOICE RLC info type |
RLC info |
RBS-925 |
|||||||
|
– CHOICE Uplink RLC mode |
AM RLC |
RBS-926 |
|||||||
|
– Transmission RLC discard |
RBS-927 |
||||||||
|
– CHOICE SDU discard mode |
No Discard |
RBS-928 |
|||||||
|
– MAX_DAT |
15 |
RBS-929 |
|||||||
|
– Transmission window size |
256 |
RBS-930 |
|||||||
|
– Timer_RST |
500 |
RBS-931 |
|||||||
|
– Max_RST |
4 |
RBS-932 |
|||||||
|
– Polling info |
RBS-933 |
||||||||
|
– Timer_poll_prohibit |
100 |
RBS-934 |
|||||||
|
– Timer_poll |
100 |
RBS-935 |
|||||||
|
– Poll_PDU |
Not Present |
RBS-936 |
|||||||
|
– Poll_SDU |
1 |
RBS-937 |
|||||||
|
– Last transmission PDU poll |
TRUE |
RBS-938 |
|||||||
|
– Last retransmission PDU poll |
TRUE |
RBS-939 |
|||||||
|
– Poll_Windows |
99 |
RBS-940 |
|||||||
|
– Timer_poll_periodic |
Not Present |
RBS-941 |
|||||||
|
– CHOICE Downlink RLC mode |
AM RLC |
RBS-942 |
|||||||
|
– CHOICE Downlink RLC PDU Size |
Reference to clause 6 Parameter Set |
RBS-943 |
|||||||
|
– In-sequence delivery |
TRUE |
RBS-944 |
|||||||
|
– Receiving window size |
768 |
RBS-945 |
|||||||
|
– Downlink RLC status info |
RBS-946 |
||||||||
|
– Timer_status_prohibit |
100 |
RBS-947 |
|||||||
|
– Timer_EPC |
Not Present |
RBS-948 |
|||||||
|
– Missing PDU indicator |
TRUE |
RBS-949 |
|||||||
|
– Timer_STATUS_periodic |
Not Present |
RBS-950 |
|||||||
|
– One sided RLC re-establishment |
FALSE |
RBS-951 |
|||||||
|
– RB mapping info |
RBS-952 |
||||||||
|
– Information for each multiplexing option |
1 RBMuxOption |
RBS-953 |
|||||||
|
– RLC logical channel mapping indicator |
Not Present |
RBS-954 |
|||||||
|
– Number of uplink RLC logical channels |
1 |
RBS-955 |
|||||||
|
– Uplink transport channel type |
E-DCH |
RBS-956 |
|||||||
|
– Logical channel identity |
7 |
RBS-957 |
|||||||
|
– E-DCH MAC-d flow identity |
2 |
RBS-958 |
|||||||
|
– CHOICE RLC PDU size |
MAC-I-FIXED |
Fixed size |
Rel-8 |
RBS-959 |
|||||
|
– DDI |
5 |
RBS-960 |
|||||||
|
– RLC PDU size list |
1 RLC PDU size |
RBS-961 |
|||||||
|
– RLC PDU size |
336 bits |
RBS-962 |
|||||||
|
– CHOICE RLC PDU size |
MAC-I-FLEX |
Flexible size |
Rel-8 |
RBS-963 |
|||||
|
– Length indicator size |
– 15 bit |
RBS-964 |
|||||||
|
– Minimum UL RLC PDU size |
See clause 6.10 |
RBS-965 |
|||||||
|
– Largest UL RLC PDU size |
See clause 6.10 |
RBS-966 |
|||||||
|
– Include in scheduling info |
TRUE |
RBS-967 |
|||||||
|
– MAC logical channel priority |
8 |
RBS-968 |
|||||||
|
– Downlink RLC logical channel info |
RBS-969 |
||||||||
|
– Number of downlink RLC logical channels |
1 |
RBS-970 |
|||||||
|
– Downlink transport channel type |
HS-DSCH |
RBS-971 |
|||||||
|
– DL DCH Transport channel identity |
Not present |
RBS-972 |
|||||||
|
– DL DSCH Transport channel identity |
Not present |
RBS-973 |
|||||||
|
– CHOICE DL MAC header type |
MAC-hs |
RBS-974 |
|||||||
|
– DL HS-DSCH MAC-d flow identity |
0 |
RBS-975 |
|||||||
|
– Logical channel identity |
Not Present |
RBS-976 |
|||||||
|
– RAB information for setup |
A21 |
Rel-7 |
RBS-977 |
||||||
|
– RAB info |
(Conversational UM DTCH for PS domain) |
RBS-978 |
|||||||
|
– RAB identity |
0000 0110B The first/ leftmost bit of the bit string contains the most significant bit of the RAB identity. |
RBS-979 |
|||||||
|
– CN domain identity |
PS domain |
RBS-980 |
|||||||
|
– NAS Synchronization Indicator |
Not Present |
RBS-981 |
|||||||
|
– Re-establishment timer |
useT314 |
RBS-982 |
|||||||
|
– RB information to setup |
RBS-983 |
||||||||
|
– RB identity |
27 |
RBS-984 |
|||||||
|
– PDCP info |
RBS-985 |
||||||||
|
– Support for lossless SRNS relocation |
FALSE |
RBS-986 |
|||||||
|
– Max PDCP SN window size |
Not present |
RBS-987 |
|||||||
|
– PDCP PDU header |
Absent |
RBS-988 |
|||||||
|
– Header compression information |
Not present |
RBS-989 |
|||||||
|
– CHOICE RLC info type |
RLC info |
RBS-990 |
|||||||
|
– CHOICE Uplink RLC mode |
UM RLC |
RBS-991 |
|||||||
|
– Transmission RLC discard |
Not present |
RBS-992 |
|||||||
|
– CHOICE Downlink RLC mode |
UM RLC |
RBS-993 |
|||||||
|
– DL UM RLC LI size |
7 |
RBS-994 |
|||||||
|
– DL Reception Window Size |
32 |
RBS-995 |
|||||||
|
– One sided RLC re-establishment |
FALSE |
RBS-996 |
|||||||
|
– Alternative E-bit interpretation |
Not present |
RBS-997 |
|||||||
|
– RB mapping info |
RBS-998 |
||||||||
|
– Information for each multiplexing option |
1 RBMuxOption |
RBS-999 |
|||||||
|
– RLC logical channel mapping indicator |
Not Present |
RBS-1000 |
|||||||
|
– Number of uplink RLC logical channels |
1 |
RBS-1001 |
|||||||
|
– Uplink transport channel type |
E-DCH |
RBS-1002 |
|||||||
|
– Logical channel identity |
9 |
RBS-1003 |
|||||||
|
– E-DCH MAC-d flow identity |
4 |
RBS-1004 |
|||||||
|
– CHOICE RLC PDU size |
MAC-I-FIXED |
Fixed size |
Rel-8 |
RBS-1005 |
|||||
|
– DDI |
7 |
RBS-1006 |
|||||||
|
– RLC PDU size list |
12 RLC PDU sizes |
RBS-1007 |
|||||||
|
– RLC PDU size |
96 bits |
RBS-1008 |
|||||||
|
– RLC PDU size |
112 bits |
RBS-1009 |
|||||||
|
– RLC PDU size |
144 bits |
RBS-1010 |
|||||||
|
– RLC PDU size |
160 bits |
RBS-1011 |
|||||||
|
– RLC PDU size |
176 bits |
RBS-1012 |
|||||||
|
– RLC PDU size |
192 bits |
RBS-1013 |
|||||||
|
– RLC PDU size |
208 bits |
RBS-1014 |
|||||||
|
– RLC PDU size |
224 bits |
RBS-1015 |
|||||||
|
– RLC PDU size |
288 bits |
RBS-1016 |
|||||||
|
– RLC PDU size |
296 bits |
RBS-1017 |
|||||||
|
– RLC PDU size |
312 bits |
RBS-1018 |
|||||||
|
– RLC PDU size |
336 bits |
RBS-1019 |
|||||||
|
– CHOICE RLC PDU size |
MAC-I-FLEX |
Flexible size |
Rel-8 |
RBS-1020 |
|||||
|
– Length indicator size |
Not present |
RBS-1021 |
|||||||
|
– Minimum UL RLC PDU size |
See clause 6.10 |
RBS-1022 |
|||||||
|
– Largest UL RLC PDU size |
See clause 6.10 |
RBS-1023 |
|||||||
|
– Include in scheduling info |
TRUE |
RBS-1024 |
|||||||
|
– MAC logical channel priority |
8 |
RBS-1025 |
|||||||
|
– Downlink RLC logical channel info |
RBS-1026 |
||||||||
|
– Number of downlink RLC logical channels |
1 |
RBS-1027 |
|||||||
|
– Downlink transport channel type |
HS-DSCH |
RBS-1028 |
|||||||
|
– DL DCH Transport channel identity |
Not present |
RBS-1029 |
|||||||
|
– DL DSCH Transport channel identity |
Not present |
RBS-1030 |
|||||||
|
– CHOICE DL MAC header type |
MAC-hs |
RBS-1031 |
|||||||
|
– DL HS-DSCH MAC-d flow identity |
3 |
RBS-1032 |
|||||||
|
– Logical channel identity |
Not Present |
RBS-1033 |
|||||||
|
– RAB information for setup |
A22 |
Rel-7 |
RBS-1034 |
||||||
|
– RAB info |
(second high-speed UM DTCH for PS domain) |
RBS-1035 |
|||||||
|
– RAB identity |
0000 0110B The first/ leftmost bit of the bit string contains the most significant bit of the RAB identity. |
RBS-1036 |
|||||||
|
– CN domain identity |
PS domain |
RBS-1037 |
|||||||
|
– NAS Synchronization Indicator |
Not Present |
RBS-1038 |
|||||||
|
– Re-establishment timer |
useT315 |
RBS-1039 |
|||||||
|
– RB information to setup |
RBS-1040 |
||||||||
|
– RB identity |
27 |
RBS-1041 |
|||||||
|
– PDCP info |
RBS-1042 |
||||||||
|
– Support for lossless SRNS relocation |
FALSE |
RBS-1043 |
|||||||
|
– Max PDCP SN window size |
Not present |
RBS-1044 |
|||||||
|
– PDCP PDU header |
Absent |
RBS-1045 |
|||||||
|
– Header compression information |
Not present |
RBS-1046 |
|||||||
|
– CHOICE RLC info type |
RLC info |
RBS-1047 |
|||||||
|
– CHOICE Uplink RLC mode |
UM RLC |
RBS-1048 |
|||||||
|
– Transmission RLC discard |
Not present |
RBS-1049 |
|||||||
|
– CHOICE Downlink RLC mode |
UM RLC |
RBS-1050 |
|||||||
|
– DL UM RLC LI size |
15 |
RBS-1051 |
|||||||
|
– DL Reception Window Size |
Not present |
RBS-1052 |
|||||||
|
– One sided RLC re-establishment |
FALSE |
RBS-1053 |
|||||||
|
– Alternative E-bit interpretation |
TRUE |
RBS-1054 |
|||||||
|
– Use special value of HE field |
Not present |
RBS-1055 |
|||||||
|
– RB mapping info |
RBS-1056 |
||||||||
|
– Information for each multiplexing option |
1 RBMuxOption |
RBS-1057 |
|||||||
|
– RLC logical channel mapping indicator |
Not present |
RBS-1058 |
|||||||
|
– Number of uplink RLC logical channels |
1 |
RBS-1059 |
|||||||
|
– Uplink transport channel type |
E-DCH |
RBS-1060 |
|||||||
|
– Logical channel identity |
9 |
RBS-1061 |
|||||||
|
– E-DCH MAC-d flow identity |
4 |
RBS-1062 |
|||||||
|
– CHOICE RLC PDU size |
MAC-I-FIXED |
Fixed size |
Rel-8 |
RBS-1063 |
|||||
|
– DDI |
7 |
RBS-1064 |
|||||||
|
– RLC PDU size list |
See clause 6.10 |
RBS-1065 |
|||||||
|
– CHOICE RLC PDU size |
MAC-I-FLEX |
Flexible size |
Rel-8 |
RBS-1066 |
|||||
|
– Length indicator size |
15 bit |
RBS-1067 |
|||||||
|
– Minimum UL RLC PDU size |
See clause 6.10 |
RBS-1068 |
|||||||
|
– Largest UL RLC PDU size |
See clause 6.10 |
RBS-1069 |
|||||||
|
– Include in scheduling info |
TRUE |
RBS-1070 |
|||||||
|
– MAC logical channel priority |
8 |
RBS-1071 |
|||||||
|
– Downlink RLC logical channel info |
RBS-1072 |
||||||||
|
– Number of downlink RLC logical channels |
1 |
RBS-1073 |
|||||||
|
– Downlink transport channel type |
HS-DSCH |
RBS-1074 |
|||||||
|
– DL DCH Transport channel identity |
Not present |
RBS-1075 |
|||||||
|
– DL DSCH Transport channel identity |
Not present |
RBS-1076 |
|||||||
|
– CHOICE DL MAC header type |
MAC-ehs |
RBS-1077 |
|||||||
|
– DL HS-DSCH MAC-ehs Queue Id |
3 |
RBS-1078 |
|||||||
|
– Logical channel identity |
9 |
RBS-1079 |
|||||||
|
– RAB information for setup |
A22 |
Rel-7 |
RBS-1080 |
||||||
|
, A25, A25b |
Rel-8 |
RBS-1081 |
|||||||
|
A25c |
Rel-9 |
RBS-1081a |
|||||||
|
– RAB info |
(high-speed AM DTCH for PS domain) |
RBS-1082 |
|||||||
|
– RAB identity |
0000 0101B The first/ leftmost bit of the bit string contains the most significant bit of the RAB identity. |
RBS-1083 |
|||||||
|
– CN domain identity |
PS domain |
RBS-1084 |
|||||||
|
– NAS Synchronization Indicator |
Not Present |
RBS-1085 |
|||||||
|
– Re-establishment timer |
useT315 |
RBS-1086 |
|||||||
|
– RB information to setup |
RBS-1087 |
||||||||
|
– RB identity |
25 |
RBS-1088 |
|||||||
|
– PDCP info |
RBS-1089 |
||||||||
|
– Support for lossless SRNS relocation |
FALSE |
RBS-1090 |
|||||||
|
– Max PDCP SN window size |
Not present |
RBS-1091 |
|||||||
|
– PDCP PDU header |
Absent |
RBS-1092 |
|||||||
|
– Header compression information |
Not present |
RBS-1093 |
|||||||
|
– CHOICE RLC info type |
RLC info |
RBS-1094 |
|||||||
|
– CHOICE Uplink RLC mode |
AM RLC |
RBS-1095 |
|||||||
|
– Transmission RLC discard |
RBS-1096 |
||||||||
|
– CHOICE SDU discard mode |
No Discard |
RBS-1097 |
|||||||
|
– MAX_DAT |
15 |
RBS-1098 |
|||||||
|
– Transmission window size |
128 |
RBS-1099 |
|||||||
|
– Timer_RST |
500 |
RBS-1100 |
|||||||
|
– Max_RST |
4 |
RBS-1101 |
|||||||
|
– Polling info |
RBS-1102 |
||||||||
|
– Timer_poll_prohibit |
100 |
RBS-1103 |
|||||||
|
– Timer_poll |
100 |
RBS-1104 |
|||||||
|
– Poll_PDU |
Not Present |
RBS-1105 |
|||||||
|
– Poll_SDU |
1 |
RBS-1106 |
|||||||
|
– Last transmission PDU poll |
TRUE |
RBS-1107 |
|||||||
|
– Last retransmission PDU poll |
TRUE |
RBS-1108 |
|||||||
|
– Poll_Windows |
99 |
RBS-1109 |
|||||||
|
– Timer_poll_periodic |
Not Present |
RBS-1110 |
|||||||
|
– CHOICE Downlink RLC mode |
AM RLC |
RBS-1111 |
|||||||
|
– CHOICE Downlink RLC PDU Size |
Reference to clause 6 Parameter Set |
RBS-1112 |
|||||||
|
– Length indicator size |
This IE is present and set to “7” if Downlink RLC PDU Size is set to “Flexible” |
RBS-1113 |
|||||||
|
– In-sequence delivery |
TRUE |
RBS-1114 |
|||||||
|
– Receiving window size |
768 |
RBS-1115 |
|||||||
|
– Downlink RLC status info |
RBS-1116 |
||||||||
|
– Timer_status_prohibit |
100 |
RBS-1117 |
|||||||
|
– Timer_EPC |
Not Present |
RBS-1118 |
|||||||
|
– Missing PDU indicator |
TRUE |
RBS-1119 |
|||||||
|
– Timer_STATUS_periodic |
Not Present |
RBS-1120 |
|||||||
|
– One sided RLC re-establishment |
FALSE |
RBS-1121 |
|||||||
|
– Alternative E-bit interpretation |
Not present |
RBS-1122 |
|||||||
|
– Use special value of HE field |
TRUE |
RBS-1123 |
|||||||
|
– RB mapping info |
RBS-1124 |
||||||||
|
– Information for each multiplexing option |
1 RBMuxOption |
RBS-1125 |
|||||||
|
– RLC logical channel mapping indicator |
Not present |
RBS-1126 |
|||||||
|
– Number of uplink RLC logical channels |
1 |
RBS-1127 |
|||||||
|
– Uplink transport channel type |
E-DCH |
RBS-1128 |
|||||||
|
– Logical channel identity |
7 |
RBS-1129 |
|||||||
|
– E-DCH MAC-d flow identity |
2 |
RBS-1130 |
|||||||
|
– CHOICE RLC PDU size |
MAC-I-FIXED |
Fixed size |
Rel-8 |
RBS-1131 |
|||||
|
– DDI |
5 |
RBS-1132 |
|||||||
|
– RLC PDU size list |
1 RLC PDU size |
RBS-1133 |
|||||||
|
– RLC PDU size |
336 bits |
RBS-1134 |
|||||||
|
– CHOICE RLC PDU size |
MAC-I-FLEX |
Flexible size |
Rel-8 |
RBS-1135 |
|||||
|
– Length indicator size |
15 bit |
RBS-1136 |
|||||||
|
– Minimum UL RLC PDU size |
See clause 6.10 |
RBS-1137 |
|||||||
|
– Largest UL RLC PDU size |
See clause 6.10 |
RBS-1138 |
|||||||
|
– Include in scheduling info |
TRUE |
RBS-1139 |
|||||||
|
– MAC logical channel priority |
8 |
RBS-1140 |
|||||||
|
– Downlink RLC logical channel info |
RBS-1141 |
||||||||
|
– Number of downlink RLC logical channels |
1 |
RBS-1142 |
|||||||
|
– Downlink transport channel type |
HS-DSCH |
RBS-1143 |
|||||||
|
– DL DCH Transport channel identity |
Not present |
RBS-1144 |
|||||||
|
– DL DSCH Transport channel identity |
Not present |
RBS-1145 |
|||||||
|
– CHOICE DL MAC header type |
MAC-ehs |
RBS-1146 |
|||||||
|
– DL HS-DSCH MAC-ehs Queue Id |
0 |
RBS-1147 |
|||||||
|
– Logical channel identity |
7 |
RBS-1148 |
|||||||
|
– RAB information for setup |
A23 |
Rel-7 Rel-8 |
RBS-1149 |
||||||
|
– RAB info |
(high-speed UM DTCH for CS domain) |
RBS-1150 |
|||||||
|
– RAB identity |
0000 0101B The first/ leftmost bit of the bit string contains the most significant bit of the RAB identity. |
RBS-1151 |
|||||||
|
– CN domain identity |
CS domain |
RBS-1152 |
|||||||
|
– NAS Synchronization Indicator |
‘1010’ if WB-AMR is tested, otherwise ‘0110’ |
RBS-1153 |
|||||||
|
– Re-establishment timer |
useT314 |
RBS-1154 |
|||||||
|
– CS-HSPA information |
RBS-1155 |
||||||||
|
– UL AMR rate |
Not Present |
RBS-1156 |
|||||||
|
– Max CS delay |
60 |
RBS-1157 |
|||||||
|
– RB information to setup |
RBS-1158 |
||||||||
|
– RB identity |
26 |
RBS-1159 |
|||||||
|
– PDCP info |
RBS-1160 |
||||||||
|
– Support for lossless SRNS relocation |
FALSE |
RBS-1161 |
|||||||
|
– Max PDCP SN window size |
Not present |
RBS-1162 |
|||||||
|
– PDCP PDU header |
present |
RBS-1163 |
|||||||
|
– Header compression information |
Not present |
RBS-1164 |
|||||||
|
– CHOICE RLC info type |
RLC info |
RBS-1165 |
|||||||
|
– CHOICE Uplink RLC mode |
UM RLC |
RBS-1166 |
|||||||
|
– Transmission RLC discard |
RBS-1167 |
||||||||
|
– CHOICE SDU discard mode |
Timer based no explicit |
RBS-1168 |
|||||||
|
– Timer_discard |
50 |
RBS-1169 |
|||||||
|
– CHOICE Downlink RLC mode |
UM RLC |
RBS-1170 |
|||||||
|
– DL UM RLC LI size |
7 |
RBS-1171 |
|||||||
|
– DL Reception Window Size |
Not present |
RBS-1172 |
|||||||
|
– One sided RLC re-establishment |
FALSE |
RBS-1173 |
|||||||
|
– Alternative E-bit interpretation |
TRUE |
RBS-1174 |
|||||||
|
– Use special value of HE field |
Not present |
RBS-1175 |
|||||||
|
– RB mapping info |
RBS-1176 |
||||||||
|
– Information for each multiplexing option |
1 RBMuxOption |
RBS-1177 |
|||||||
|
– RLC logical channel mapping indicator |
Not present |
RBS-1178 |
|||||||
|
– Number of uplink RLC logical channels |
1 |
RBS-1179 |
|||||||
|
– Uplink transport channel type |
E-DCH |
RBS-1180 |
|||||||
|
– Logical channel identity |
7 |
RBS-1181 |
|||||||
|
– E-DCH MAC-d flow identity |
2 |
RBS-1182 |
|||||||
|
– CHOICE RLC PDU size |
MAC-I-FIXED |
Fixed size |
Rel-8 |
RBS-1183 |
|||||
|
– DDI |
6 |
RBS-1184 |
|||||||
|
– RLC PDU size list |
Reference to clause 6.10 Parameter Set |
RBS-1185 |
|||||||
|
– CHOICE RLC PDU size |
MAC-I-FLEX |
Flexible size |
Rel-8 |
RBS-1186 |
|||||
|
– Length indicator size |
Not present |
RBS-1187 |
|||||||
|
– Minimum UL RLC PDU size |
See clause 6.10 |
RBS-1188 |
|||||||
|
– Largest UL RLC PDU size |
See clause 6.10 |
RBS-1189 |
|||||||
|
– Include in scheduling info |
TRUE |
RBS-1190 |
|||||||
|
– MAC logical channel priority |
8 |
RBS-1191 |
|||||||
|
– Downlink RLC logical channel info |
RBS-1192 |
||||||||
|
– Number of downlink RLC logical channels |
1 |
RBS-1193 |
|||||||
|
– Downlink transport channel type |
HS-DSCH |
RBS-1194 |
|||||||
|
– DL DCH Transport channel identity |
Not present |
RBS-1195 |
|||||||
|
– DL DSCH Transport channel identity |
Not present |
RBS-1196 |
|||||||
|
– CHOICE DL MAC header type |
MAC-ehs |
RBS-1197 |
|||||||
|
– DL HS-DSCH MAC-ehs Queue Id |
0 |
RBS-1198 |
|||||||
|
– Logical channel identity |
7 |
RBS-1199 |
|||||||
|
– RAB information for setup |
A24 |
RBS-1200 |
|||||||
|
– RAB info |
(high-speed AM DTCH for PS domain) |
RBS-1201 |
|||||||
|
– RAB identity |
0000 0101B The first/ leftmost bit of the bit string contains the most significant bit of the RAB identity. |
RBS-1202 |
|||||||
|
– CN domain identity |
PS domain |
RBS-1203 |
|||||||
|
– NAS Synchronization Indicator |
Not Present |
RBS-1204 |
|||||||
|
– Re-establishment timer |
useT315 |
RBS-1205 |
|||||||
|
– RB information to setup |
RBS-1206 |
||||||||
|
– RB identity |
25 |
RBS-1207 |
|||||||
|
– PDCP info |
RBS-1208 |
||||||||
|
– Support for lossless SRNS relocation |
FALSE |
RBS-1209 |
|||||||
|
– Max PDCP SN window size |
Not present |
RBS-1210 |
|||||||
|
– PDCP PDU header |
Absent |
RBS-1211 |
|||||||
|
– Header compression information |
Not present |
RBS-1212 |
|||||||
|
– CHOICE RLC info type |
RLC info |
RBS-1213 |
|||||||
|
– CHOICE Uplink RLC mode |
AM RLC |
RBS-1214 |
|||||||
|
– Transmission RLC discard |
RBS-1215 |
||||||||
|
– CHOICE SDU discard mode |
No Discard |
RBS-1216 |
|||||||
|
– MAX_DAT |
15 |
RBS-1217 |
|||||||
|
– Transmission window size |
128 |
RBS-1218 |
|||||||
|
– Timer_RST |
500 |
RBS-1219 |
|||||||
|
– Max_RST |
4 |
RBS-1220 |
|||||||
|
– Polling info |
RBS-1221 |
||||||||
|
– Timer_poll_prohibit |
100 |
RBS-1222 |
|||||||
|
– Timer_poll |
100 |
RBS-1223 |
|||||||
|
– Poll_PDU |
Not Present |
RBS-1224 |
|||||||
|
– Poll_SDU |
1 |
RBS-1225 |
|||||||
|
– Last transmission PDU poll |
TRUE |
RBS-1226 |
|||||||
|
– Last retransmission PDU poll |
TRUE |
RBS-1227 |
|||||||
|
– Poll_Windows |
99 |
RBS-1228 |
|||||||
|
– Timer_poll_periodic |
Not Present |
RBS-1229 |
|||||||
|
– CHOICE Downlink RLC mode |
AM RLC |
RBS-1230 |
|||||||
|
– CHOICE Downlink RLC PDU Size |
Reference to clause 6 Parameter Set |
RBS-1231 |
|||||||
|
– In-sequence delivery |
TRUE |
RBS-1232 |
|||||||
|
– Receiving window size |
768 |
RBS-1233 |
|||||||
|
– Downlink RLC status info |
RBS-1234 |
||||||||
|
– Timer_status_prohibit |
100 |
RBS-1235 |
|||||||
|
– Timer_EPC |
Not Present |
RBS-1236 |
|||||||
|
– Missing PDU indicator |
TRUE |
RBS-1237 |
|||||||
|
– Timer_STATUS_periodic |
Not Present |
RBS-1238 |
|||||||
|
– One sided RLC re-establishment |
FALSE |
RBS-1239 |
|||||||
|
– Alternative E-bit interpretation |
Not present |
RBS-1240 |
|||||||
|
– Use special value of HE field |
TRUE |
RBS-1241 |
|||||||
|
– RB mapping info |
RBS-1242 |
||||||||
|
– Information for each multiplexing option |
1 RBMuxOption |
RBS-1243 |
|||||||
|
– RLC logical channel mapping indicator |
Not present |
RBS-1244 |
|||||||
|
– Number of uplink RLC logical channels |
1 |
RBS-1245 |
|||||||
|
– Uplink transport channel type |
RACH |
RBS-1246 |
|||||||
|
– UL Transport channel identity |
Not Present |
RBS-1247 |
|||||||
|
– Logical channel identity |
7 |
RBS-1248 |
|||||||
|
– CHOICE RLC size list |
Explicit list |
RBS-1249 |
|||||||
|
– RLC size index |
|
Reference to clause 6 Parameter Set |
RBS-1250 |
||||||
|
– MAC logical channel priority |
8 |
RBS-1251 |
|||||||
|
– Downlink RLC logical channel info |
RBS-1252 |
||||||||
|
– Number of downlink RLC logical channels |
1 |
RBS-1253 |
|||||||
|
– Downlink transport channel type |
HS-DSCH |
RBS-1254 |
|||||||
|
– DL DCH Transport channel identity |
Not present |
RBS-1255 |
|||||||
|
– DL DSCH Transport channel identity |
Not present |
RBS-1256 |
|||||||
|
– CHOICE DL MAC header type |
MAC-ehs |
RBS-1257 |
|||||||
|
– DL HS-DSCH MAC-ehs Queue Id |
2 |
RBS-1258 |
|||||||
|
– Logical channel identity |
Not Present |
RBS-1259 |
|||||||
|
– RAB information for setup |
A26 |
Rel-8 |
RBS-1260 |
||||||
|
– RAB info |
(first UM DTCH for PS domain) |
RBS-1261 |
|||||||
|
– RAB identity |
0000 0101B The first/ leftmost bit of the bit string contains the most significant bit of the RAB identity. |
RBS-1262 |
|||||||
|
– CN domain identity |
PS domain |
RBS-1263 |
|||||||
|
– NAS Synchronization Indicator |
Not Present |
RBS-1264 |
|||||||
|
– Re-establishment timer |
useT315 |
RBS-1265 |
|||||||
|
– RB information to setup |
RBS-1266 |
||||||||
|
– RB identity |
26 |
RBS-1267 |
|||||||
|
– PDCP info |
RBS-1268 |
||||||||
|
– Support for lossless SRNS relocation |
FALSE |
RBS-1269 |
|||||||
|
– Max PDCP SN window size |
Not present |
RBS-1270 |
|||||||
|
– PDCP PDU header |
Absent |
RBS-1271 |
|||||||
|
– Header compression information |
Not present |
RBS-1272 |
|||||||
|
– CHOICE RLC info type |
RLC info |
RBS-1273 |
|||||||
|
– CHOICE Uplink RLC mode |
UM RLC |
RBS-1274 |
|||||||
|
– Transmission RLC discard |
Not present |
RBS-1275 |
|||||||
|
– CHOICE Downlink RLC mode |
UM RLC |
RBS-1276 |
|||||||
|
– DL UM RLC LI size |
7 |
RBS-1277 |
|||||||
|
– DL Reception Window Size |
Not present |
RBS-1278 |
|||||||
|
– Alternative E-bit interpretation |
TRUE |
RBS-1279 |
|||||||
|
– One sided RLC re-establishment |
FALSE |
RBS-1280 |
|||||||
|
– RB mapping info |
RBS-1281 |
||||||||
|
– Information for each multiplexing option |
1 RBMuxOption |
RBS-1282 |
|||||||
|
– RLC logical channel mapping indicator |
Not Present |
RBS-1283 |
|||||||
|
– Number of uplink RLC logical channels |
1 |
RBS-1284 |
|||||||
|
– Uplink transport channel type |
E-DCH |
RBS-1285 |
|||||||
|
– Logical channel identity |
7 |
RBS-1286 |
|||||||
|
– E-DCH MAC-d flow identity |
2 |
RBS-1287 |
|||||||
|
– CHOICE RLC PDU size |
Flexible size |
RBS-1288 |
|||||||
|
– Length indicator size |
Not present |
RBS-1289 |
|||||||
|
– Minimum UL RLC PDU size |
See clause 6.10 |
RBS-1290 |
|||||||
|
– Largest UL RLC PDU size |
See clause 6.10 |
RBS-1291 |
|||||||
|
– Include in scheduling info |
TRUE |
RBS-1292 |
|||||||
|
– MAC logical channel priority |
8 |
RBS-1293 |
|||||||
|
– Downlink RLC logical channel info |
RBS-1294 |
||||||||
|
– Number of downlink RLC logical channels |
1 |
RBS-1295 |
|||||||
|
– Downlink transport channel type |
HS-DSCH |
RBS-1296 |
|||||||
|
– DL DCH Transport channel identity |
Not present |
RBS-1297 |
|||||||
|
– DL DSCH Transport channel identity |
Not present |
RBS-1298 |
|||||||
|
– CHOICE DL MAC header type |
MAC-ehs |
RBS-1299 |
|||||||
|
– DL HS-DSCH MAC-ehs Queue Id |
2 |
RBS-1300 |
|||||||
|
– Logical channel identity |
7 |
RBS-1301 |
|||||||
|
– RAB information for setup |
A26 |
Rel-8 |
RBS-1302 |
||||||
|
– RAB info |
(second high-speed UM DTCH for PS domain) |
RBS-1303 |
|||||||
|
– RAB identity |
0000 0110B The first/ leftmost bit of the bit string contains the most significant bit of the RAB identity. |
RBS-1304 |
|||||||
|
– CN domain identity |
PS domain |
RBS-1305 |
|||||||
|
– NAS Synchronization Indicator |
Not Present |
RBS-1306 |
|||||||
|
– Re-establishment timer |
useT315 |
RBS-1307 |
|||||||
|
– RB information to setup |
RBS-1308 |
||||||||
|
– RB identity |
27 |
RBS-1309 |
|||||||
|
– PDCP info |
RBS-1310 |
||||||||
|
– Support for lossless SRNS relocation |
FALSE |
RBS-1311 |
|||||||
|
– Max PDCP SN window size |
Not present |
RBS-1312 |
|||||||
|
– PDCP PDU header |
Absent |
RBS-1313 |
|||||||
|
– Header compression information |
Not present |
RBS-1314 |
|||||||
|
– CHOICE RLC info type |
RLC info |
RBS-1315 |
|||||||
|
– CHOICE Uplink RLC mode |
UM RLC |
RBS-1316 |
|||||||
|
– Transmission RLC discard |
Not present |
RBS-1317 |
|||||||
|
– CHOICE Downlink RLC mode |
UM RLC |
RBS-1318 |
|||||||
|
– DL UM RLC LI size |
7 |
RBS-1319 |
|||||||
|
– DL Reception Window Size |
Not present |
RBS-1320 |
|||||||
|
– Alternative E-bit interpretation |
TRUE |
RBS-1321 |
|||||||
|
– One sided RLC re-establishment |
FALSE |
RBS-1322 |
|||||||
|
– RB mapping info |
RBS-1323 |
||||||||
|
– Information for each multiplexing option |
1 RBMuxOption |
RBS-1324 |
|||||||
|
– RLC logical channel mapping indicator |
Not Present |
RBS-1325 |
|||||||
|
– Number of uplink RLC logical channels |
1 |
RBS-1326 |
|||||||
|
– Uplink transport channel type |
E-DCH |
RBS-1327 |
|||||||
|
– Logical channel identity |
8 |
RBS-1328 |
|||||||
|
– E-DCH MAC-d flow identity |
3 |
RBS-1329 |
|||||||
|
– CHOICE RLC PDU size |
Flexible size |
RBS-1330 |
|||||||
|
– Length indicator size |
Not present |
RBS-1331 |
|||||||
|
– Minimum UL RLC PDU size |
See clause 6.10 |
RBS-1332 |
|||||||
|
– Largest UL RLC PDU size |
See clause 6.10 |
RBS-1333 |
|||||||
|
– Include in scheduling info |
TRUE |
RBS-1334 |
|||||||
|
– MAC logical channel priority |
8 |
RBS-1335 |
|||||||
|
– Downlink RLC logical channel info |
RBS-1336 |
||||||||
|
– Number of downlink RLC logical channels |
1 |
RBS-1337 |
|||||||
|
– Downlink transport channel type |
HS-DSCH |
RBS-1338 |
|||||||
|
– DL DCH Transport channel identity |
Not present |
RBS-1339 |
|||||||
|
– DL DSCH Transport channel identity |
Not present |
RBS-1340 |
|||||||
|
– CHOICE DL MAC header type |
MAC-ehs |
RBS-1341 |
|||||||
|
– DL HS-DSCH MAC-ehs Queue Id |
3 |
RBS-1342 |
|||||||
|
– Logical channel identity |
8 |
RBS-1343 |
|||||||
|
– RAB information for setup |
A26 |
Rel-8 |
RBS-1344 |
||||||
|
– RAB info |
(third high-speed UM DTCH for PS domain) |
RBS-1345 |
|||||||
|
– RAB identity |
0000 0111B The first/ leftmost bit of the bit string contains the most significant bit of the RAB identity. |
RBS-1346 |
|||||||
|
– CN domain identity |
PS domain |
RBS-1347 |
|||||||
|
– NAS Synchronization Indicator |
Not Present |
RBS-1348 |
|||||||
|
– Re-establishment timer |
useT315 |
RBS-1349 |
|||||||
|
– RB information to setup |
RBS-1350 |
||||||||
|
– RB identity |
21 |
RBS-1351 |
|||||||
|
– PDCP info |
RBS-1352 |
||||||||
|
– Support for lossless SRNS relocation |
FALSE |
RBS-1353 |
|||||||
|
– Max PDCP SN window size |
Not present |
RBS-1354 |
|||||||
|
– PDCP PDU header |
Absent |
RBS-1355 |
|||||||
|
– Header compression information |
Not present |
RBS-1356 |
|||||||
|
– CHOICE RLC info type |
RLC info |
RBS-1357 |
|||||||
|
– CHOICE Uplink RLC mode |
UM RLC |
RBS-1358 |
|||||||
|
– Transmission RLC discard |
Not present |
RBS-1359 |
|||||||
|
– CHOICE Downlink RLC mode |
UM RLC |
RBS-1360 |
|||||||
|
– DL UM RLC LI size |
7 |
RBS-1361 |
|||||||
|
– DL Reception Window Size |
Not present |
RBS-1362 |
|||||||
|
– Alternative E-bit interpretation |
TRUE |
RBS-1363 |
|||||||
|
– One sided RLC re-establishment |
FALSE |
RBS-1364 |
|||||||
|
– RB mapping info |
RBS-1365 |
||||||||
|
– Information for each multiplexing option |
1 RBMuxOption |
RBS-1366 |
|||||||
|
– RLC logical channel mapping indicator |
Not Present |
RBS-1367 |
|||||||
|
– Number of uplink RLC logical channels |
1 |
RBS-1368 |
|||||||
|
– Uplink transport channel type |
E-DCH |
RBS-1369 |
|||||||
|
– Logical channel identity |
9 |
RBS-1370 |
|||||||
|
– E-DCH MAC-d flow identity |
4 |
RBS-1371 |
|||||||
|
– CHOICE RLC PDU size |
Flexible size |
RBS-1372 |
|||||||
|
– Length indicator size |
Not present |
RBS-1373 |
|||||||
|
– Minimum UL RLC PDU size |
See clause 6.10 |
RBS-1374 |
|||||||
|
– Largest UL RLC PDU size |
See clause 6.10 |
RBS-1375 |
|||||||
|
– Include in scheduling info |
TRUE |
RBS-1376 |
|||||||
|
– MAC logical channel priority |
8 |
RBS-1377 |
|||||||
|
– Downlink RLC logical channel info |
RBS-1378 |
||||||||
|
– Number of downlink RLC logical channels |
1 |
RBS-1379 |
|||||||
|
– Downlink transport channel type |
HS-DSCH |
RBS-1380 |
|||||||
|
– DL DCH Transport channel identity |
Not present |
RBS-1381 |
|||||||
|
– DL DSCH Transport channel identity |
Not present |
RBS-1382 |
|||||||
|
– CHOICE DL MAC header type |
MAC-ehs |
RBS-1383 |
|||||||
|
– DL HS-DSCH MAC-ehs Queue Id |
4 |
RBS-1384 |
|||||||
|
– Logical channel identity |
9 |
RBS-1385 |
|||||||
|
– RAB information for setup |
A27, A27a |
Rel-8 |
RBS-1386 |
||||||
|
– RAB info |
(high-speed UM DTCH for PS domain) |
RBS-1387 |
|||||||
|
– RAB identity |
0000 0101B The first/ leftmost bit of the bit string contains the most significant bit of the RAB identity. |
RBS-1388 |
|||||||
|
– CN domain identity |
PS domain |
RBS-1389 |
|||||||
|
– NAS Synchronization Indicator |
Not Present |
RBS-1390 |
|||||||
|
– Re-establishment timer |
useT315 |
RBS-1391 |
|||||||
|
– RB information to setup |
RBS-1392 |
||||||||
|
– RB identity |
25 |
RBS-1393 |
|||||||
|
– PDCP info |
RBS-1394 |
||||||||
|
– Support for lossless SRNS relocation |
FALSE |
RBS-1395 |
|||||||
|
– Max PDCP SN window size |
Not present |
RBS-1396 |
|||||||
|
– PDCP PDU header |
Absent |
RBS-1397 |
|||||||
|
– Header compression information |
Not present |
RBS-1398 |
|||||||
|
– CHOICE RLC info type |
RLC info |
RBS-1399 |
|||||||
|
– CHOICE Uplink RLC mode |
UM RLC |
RBS-1400 |
|||||||
|
– Transmission RLC discard |
Not Present |
RBS-1401 |
|||||||
|
– CHOICE Downlink RLC mode |
UM RLC |
RBS-1402 |
|||||||
|
– DL UM RLC LI size |
15 |
RBS-1403 |
|||||||
|
– DL Reception Window Size |
Not present |
RBS-1404 |
|||||||
|
– One sided RLC re-establishment |
FALSE |
RBS-1405 |
|||||||
|
– Alternative E-bit interpretation |
TRUE |
RBS-1406 |
|||||||
|
– Use special value of HE field |
Not present |
RBS-1407 |
|||||||
|
– RB mapping info |
RBS-1408 |
||||||||
|
– Information for each multiplexing option |
1 RBMuxOption |
RBS-1409 |
|||||||
|
– RLC logical channel mapping indicator |
Not present |
RBS-1410 |
|||||||
|
– Number of uplink RLC logical channels |
1 |
RBS-1411 |
|||||||
|
– Uplink transport channel type |
E-DCH |
RBS-1412 |
|||||||
|
– Logical channel identity |
7 |
RBS-1413 |
|||||||
|
– E-DCH MAC-d flow identity |
2 |
RBS-1414 |
|||||||
|
– CHOICE RLC PDU size |
Flexible size |
RBS-1415 |
|||||||
|
– Length indicator size |
Not present |
RBS-1416 |
|||||||
|
– Minimum UL RLC PDU size |
See clause 6.10 |
RBS-1417 |
|||||||
|
– Largest UL RLC PDU size |
See clause 6.10 |
RBS-1418 |
|||||||
|
– Include in scheduling info |
TRUE |
RBS-1419 |
|||||||
|
– MAC logical channel priority |
8 |
RBS-1420 |
|||||||
|
– Downlink RLC logical channel info |
RBS-1421 |
||||||||
|
– Number of downlink RLC logical channels |
1 |
RBS-1422 |
|||||||
|
– Downlink transport channel type |
HS-DSCH |
RBS-1423 |
|||||||
|
– DL DCH Transport channel identity |
Not present |
RBS-1424 |
|||||||
|
– DL DSCH Transport channel identity |
Not present |
RBS-1425 |
|||||||
|
– CHOICE DL MAC header type |
MAC-ehs |
RBS-1426 |
|||||||
|
– DL HS-DSCH MAC-ehs Queue Id |
0 |
RBS-1427 |
|||||||
|
– Logical channel identity |
7 |
RBS-1428 |
|||||||
|
– RAB information for setup |
A29 |
Rel-8 |
RBS-1429 |
||||||
|
– RAB info |
(high-speed AM DTCH for PS domain) |
RBS-1430 |
|||||||
|
– RAB identity |
0000 0101B |
RBS-1431 |
|||||||
|
The first/ leftmost bit of the bit string contains the most significant bit of the RAB identity. |
RBS-1432 |
||||||||
|
– CN domain identity |
PS domain |
RBS-1433 |
|||||||
|
– NAS Synchronization Indicator |
Not Present |
RBS-1434 |
|||||||
|
– Re-establishment timer |
useT315 |
RBS-1435 |
|||||||
|
– RB information to setup |
RBS-1436 |
||||||||
|
– RB identity |
25 |
RBS-1437 |
|||||||
|
– PDCP info |
RBS-1438 |
||||||||
|
– Support for lossless SRNS relocation |
FALSE |
RBS-1439 |
|||||||
|
– Max PDCP SN window size |
Not present |
RBS-1440 |
|||||||
|
– PDCP PDU header |
Absent |
RBS-1441 |
|||||||
|
– Header compression information |
Not present |
RBS-1442 |
|||||||
|
– CHOICE RLC info type |
RLC info |
RBS-1443 |
|||||||
|
– CHOICE Uplink RLC mode |
AM RLC |
RBS-1444 |
|||||||
|
– Transmission RLC discard |
RBS-1445 |
||||||||
|
– CHOICE SDU discard mode |
No Discard |
RBS-1446 |
|||||||
|
– MAX_DAT |
15 |
RBS-1447 |
|||||||
|
– Transmission window size |
128 |
RBS-1448 |
|||||||
|
– Timer_RST |
500 |
RBS-1449 |
|||||||
|
– Max_RST |
4 |
RBS-1450 |
|||||||
|
– Polling info |
RBS-1451 |
||||||||
|
– Timer_poll_prohibit |
100 |
RBS-1452 |
|||||||
|
– Timer_poll |
100 |
RBS-1453 |
|||||||
|
– Poll_PDU |
Not Present |
RBS-1454 |
|||||||
|
– Poll_SDU |
1 |
RBS-1455 |
|||||||
|
– Last transmission PDU poll |
TRUE |
RBS-1456 |
|||||||
|
– Last retransmission PDU poll |
TRUE |
RBS-1457 |
|||||||
|
– Poll_Windows |
99 |
RBS-1458 |
|||||||
|
– Timer_poll_periodic |
Not Present |
RBS-1459 |
|||||||
|
– CHOICE Downlink RLC mode |
AM RLC |
RBS-1460 |
|||||||
|
– CHOICE Downlink RLC PDU Size |
Reference to clause 6 Parameter Set |
RBS-1461 |
|||||||
|
– In-sequence delivery |
TRUE |
RBS-1462 |
|||||||
|
– Receiving window size |
768 |
RBS-1463 |
|||||||
|
– Downlink RLC status info |
RBS-1464 |
||||||||
|
– Timer_status_prohibit |
100 |
RBS-1465 |
|||||||
|
– Timer_EPC |
Not Present |
RBS-1466 |
|||||||
|
– Missing PDU indicator |
TRUE |
RBS-1467 |
|||||||
|
– Timer_STATUS_periodic |
Not Present |
RBS-1468 |
|||||||
|
– One sided RLC re-establishment |
FALSE |
RBS-1469 |
|||||||
|
– Alternative E-bit interpretation |
Not present |
RBS-1470 |
|||||||
|
– Use special value of HE field |
TRUE |
RBS-1471 |
|||||||
|
– RB mapping info |
RBS-1472 |
||||||||
|
– Information for each multiplexing option |
1 RBMuxOption |
RBS-1473 |
|||||||
|
– RLC logical channel mapping indicator |
Not present |
RBS-1474 |
|||||||
|
– Number of uplink RLC logical channels |
1 |
RBS-1475 |
|||||||
|
– Uplink transport channel type |
E-DCH |
RBS-1476 |
|||||||
|
– Logical channel identity |
7 |
RBS-1477 |
|||||||
|
– E-DCH MAC-d flow identity |
0 |
RBS-1478 |
|||||||
|
– CHOICE RLC PDU size |
Flexible size |
RBS-1479 |
|||||||
|
– Length indicator size |
15 bit |
RBS-1480 |
|||||||
|
– Minimum UL RLC PDU size |
See clause 6.10 |
RBS-1481 |
|||||||
|
– Largest UL RLC PDU size |
See clause 6.10 |
RBS-1482 |
|||||||
|
– Include in scheduling info |
TRUE |
RBS-1483 |
|||||||
|
– MAC logical channel priority |
8 |
RBS-1484 |
|||||||
|
– Downlink RLC logical channel info |
RBS-1485 |
||||||||
|
– Number of downlink RLC logical channels |
1 |
RBS-1486 |
|||||||
|
– Downlink transport channel type |
HS-DSCH |
RBS-1487 |
|||||||
|
– DL DCH Transport channel identity |
Not present |
RBS-1488 |
|||||||
|
– DL DSCH Transport channel identity |
Not present |
RBS-1489 |
|||||||
|
– CHOICE DL MAC header type |
MAC-ehs |
RBS-1490 |
|||||||
|
– DL HS-DSCH MAC-ehs Queue Id |
2 |
RBS-1491 |
|||||||
|
– Logical channel identity |
7 |
RBS-1492 |
|||||||
|
– RAB information for setup |
A30 |
Rel-8 |
RBS-1493 |
||||||
|
– RAB info |
(high-speed AM DTCH for PS domain) |
RBS-1494 |
|||||||
|
– RAB identity |
0000 0101B |
RBS-1495 |
|||||||
|
The first/ leftmost bit of the bit string contains the most significant bit of the RAB identity. |
RBS-1496 |
||||||||
|
– CN domain identity |
PS domain |
RBS-1497 |
|||||||
|
– NAS Synchronization Indicator |
Not Present |
RBS-1498 |
|||||||
|
– Re-establishment timer |
useT315 |
RBS-1499 |
|||||||
|
– RB information to setup |
RBS-1500 |
||||||||
|
– RB identity |
25 |
RBS-1501 |
|||||||
|
– PDCP info |
RBS-1502 |
||||||||
|
– Support for lossless SRNS relocation |
FALSE |
RBS-1503 |
|||||||
|
– Max PDCP SN window size |
Not present |
RBS-1504 |
|||||||
|
– PDCP PDU header |
Absent |
RBS-1505 |
|||||||
|
– Header compression information |
Not present |
RBS-1506 |
|||||||
|
– CHOICE RLC info type |
RLC info |
RBS-1507 |
|||||||
|
– CHOICE Uplink RLC mode |
AM RLC |
RBS-1508 |
|||||||
|
– Transmission RLC discard |
RBS-1509 |
||||||||
|
– CHOICE SDU discard mode |
No Discard |
RBS-1510 |
|||||||
|
– MAX_DAT |
15 |
RBS-1511 |
|||||||
|
– Transmission window size |
128 |
RBS-1512 |
|||||||
|
– Timer_RST |
500 |
RBS-1513 |
|||||||
|
– Max_RST |
4 |
RBS-1514 |
|||||||
|
– Polling info |
RBS-1515 |
||||||||
|
– Timer_poll_prohibit |
100 |
RBS-1516 |
|||||||
|
– Timer_poll |
100 |
RBS-1517 |
|||||||
|
– Poll_PDU |
Not Present |
RBS-1518 |
|||||||
|
– Poll_SDU |
1 |
RBS-1519 |
|||||||
|
– Last transmission PDU poll |
TRUE |
RBS-1520 |
|||||||
|
– Last retransmission PDU poll |
TRUE |
RBS-1521 |
|||||||
|
– Poll_Windows |
99 |
RBS-1522 |
|||||||
|
– Timer_poll_periodic |
Not Present |
RBS-1523 |
|||||||
|
– CHOICE Downlink RLC mode |
AM RLC |
RBS-1524 |
|||||||
|
– CHOICE Downlink RLC PDU Size |
Reference to clause 6 Parameter Set |
RBS-1525 |
|||||||
|
– In-sequence delivery |
TRUE |
RBS-1526 |
|||||||
|
– Receiving window size |
768 |
RBS-1527 |
|||||||
|
– Downlink RLC status info |
RBS-1528 |
||||||||
|
– Timer_status_prohibit |
100 |
RBS-1529 |
|||||||
|
– Timer_EPC |
Not Present |
RBS-1530 |
|||||||
|
– Missing PDU indicator |
TRUE |
RBS-1531 |
|||||||
|
– Timer_STATUS_periodic |
Not Present |
RBS-1532 |
|||||||
|
– One sided RLC re-establishment |
FALSE |
RBS-1533 |
|||||||
|
– Alternative E-bit interpretation |
Not present |
RBS-1534 |
|||||||
|
– Use special value of HE field |
TRUE |
RBS-1535 |
|||||||
|
– RB mapping info |
RBS-1536 |
||||||||
|
– Information for each multiplexing option |
1 RBMuxOption |
RBS-1537 |
|||||||
|
– RLC logical channel mapping indicator |
Not present |
RBS-1538 |
|||||||
|
– Number of uplink RLC logical channels |
1 |
RBS-1539 |
|||||||
|
– Uplink transport channel type |
E-DCH |
RBS-1540 |
|||||||
|
– Logical channel identity |
7 |
RBS-1541 |
|||||||
|
– E-DCH MAC-d flow identity |
2 |
RBS-1542 |
|||||||
|
– CHOICE RLC PDU size |
Flexible size |
RBS-1543 |
|||||||
|
– Length indicator size |
15 bit |
RBS-1544 |
|||||||
|
– Minimum UL RLC PDU size |
See clause 6.10 |
RBS-1545 |
|||||||
|
– Largest UL RLC PDU size |
See clause 6.10 |
RBS-1546 |
|||||||
|
– Include in scheduling info |
TRUE |
RBS-1547 |
|||||||
|
– MAC logical channel priority |
8 |
RBS-1548 |
|||||||
|
– Downlink RLC logical channel info |
RBS-1549 |
||||||||
|
– Number of downlink RLC logical channels |
1 |
RBS-1550 |
|||||||
|
– Downlink transport channel type |
HS-DSCH |
RBS-1551 |
|||||||
|
– DL DCH Transport channel identity |
Not present |
RBS-1552 |
|||||||
|
– DL DSCH Transport channel identity |
Not present |
RBS-1553 |
|||||||
|
– CHOICE DL MAC header type |
MAC-ehs |
RBS-1554 |
|||||||
|
– DL HS-DSCH MAC-ehs Queue Id |
2 |
RBS-1555 |
|||||||
|
– Logical channel identity |
7 |
RBS-1556 |
|||||||
|
– RAB information for setup |
A31, A32 |
Rel-9 |
RBS-1557 |
||||||
|
– RAB info |
(high-speed AM DTCH for PS domain) |
RBS-1558 |
|||||||
|
– RAB identity |
0000 0101B The first/ leftmost bit of the bit string contains the most significant bit of the RAB identity. |
RBS-1559 |
|||||||
|
– CN domain identity |
PS domain |
RBS-1560 |
|||||||
|
– NAS Synchronization Indicator |
Not Present |
RBS-1561 |
|||||||
|
– Re-establishment timer |
useT315 |
RBS-1562 |
|||||||
|
– RB information to setup |
RBS-1563 |
||||||||
|
– RB identity |
25 |
RBS-1564 |
|||||||
|
– PDCP info |
RBS-1565 |
||||||||
|
– Support for lossless SRNS relocation |
FALSE |
RBS-1566 |
|||||||
|
– Max PDCP SN window size |
Not present |
RBS-1567 |
|||||||
|
– PDCP PDU header |
Absent |
RBS-1568 |
|||||||
|
– Header compression information |
Not present |
RBS-1569 |
|||||||
|
– CHOICE RLC info type |
RLC info |
RBS-1570 |
|||||||
|
– CHOICE Uplink RLC mode |
AM RLC |
RBS-1571 |
|||||||
|
– Transmission RLC discard |
RBS-1572 |
||||||||
|
– CHOICE SDU discard mode |
No Discard |
RBS-1573 |
|||||||
|
– MAX_DAT |
15 |
RBS-1574 |
|||||||
|
– Transmission window size |
2047 |
RBS-1575 |
|||||||
|
– Timer_RST |
500 |
RBS-1576 |
|||||||
|
– Max_RST |
4 |
RBS-1577 |
|||||||
|
– Polling info |
RBS-1578 |
||||||||
|
– Timer_poll_prohibit |
100 |
RBS-1579 |
|||||||
|
– Timer_poll |
100 |
RBS-1580 |
|||||||
|
– Poll_PDU |
Not Present |
RBS-1581 |
|||||||
|
– Poll_SDU |
1 |
RBS-1582 |
|||||||
|
– Last transmission PDU poll |
TRUE |
RBS-1583 |
|||||||
|
– Last retransmission PDU poll |
TRUE |
RBS-1584 |
|||||||
|
– Poll_Windows |
50 |
RBS-1585 |
|||||||
|
– Timer_poll_periodic |
Not Present |
RBS-1586 |
|||||||
|
– CHOICE Downlink RLC mode |
AM RLC |
RBS-1587 |
|||||||
|
– CHOICE Downlink RLC PDU Size |
Reference to clause 6 Parameter Set |
RBS-1588 |
|||||||
|
– Length indicator size |
This IE is present and set to “7” if Downlink RLC PDU Size is set to “Flexible” |
RBS-1589 |
|||||||
|
– In-sequence delivery |
TRUE |
RBS-1590 |
|||||||
|
– Receiving window size |
2047 |
RBS-1591 |
|||||||
|
– Downlink RLC status info |
RBS-1592 |
||||||||
|
– Timer_status_prohibit |
80 |
RBS-1593 |
|||||||
|
– Timer_EPC |
Not Present |
RBS-1594 |
|||||||
|
– Missing PDU indicator |
TRUE |
RBS-1595 |
|||||||
|
– Timer_STATUS_periodic |
Not Present |
RBS-1596 |
|||||||
|
– One sided RLC re-establishment |
FALSE |
RBS-1597 |
|||||||
|
– Alternative E-bit interpretation |
Not present |
RBS-1598 |
|||||||
|
– Use special value of HE field |
TRUE |
RBS-1599 |
|||||||
|
– RB mapping info |
RBS-1600 |
||||||||
|
– Information for each multiplexing option |
1 RBMuxOption |
RBS-1601 |
|||||||
|
– RLC logical channel mapping indicator |
Not present |
RBS-1602 |
|||||||
|
– Number of uplink RLC logical channels |
1 |
RBS-1603 |
|||||||
|
– Uplink transport channel type |
E-DCH |
RBS-1604 |
|||||||
|
– Logical channel identity |
7 |
RBS-1605 |
|||||||
|
– E-DCH MAC-d flow identity |
2 |
RBS-1606 |
|||||||
|
– CHOICE RLC PDU size |
Fixed size |
RBS-1607 |
|||||||
|
– DDI |
7 |
RBS-1608 |
|||||||
|
– RLC PDU size list |
See clause 6.10 |
RBS-1609 |
|||||||
|
– Include in scheduling info |
TRUE |
RBS-1611 |
|||||||
|
– MAC logical channel priority |
8 |
RBS-1612 |
|||||||
|
– Downlink RLC logical channel info |
RBS-1613 |
||||||||
|
– Number of downlink RLC logical channels |
1 |
RBS-1614 |
|||||||
|
– Downlink transport channel type |
HS-DSCH |
RBS-1615 |
|||||||
|
– DL DCH Transport channel identity |
Not present |
RBS-1616 |
|||||||
|
– DL DSCH Transport channel identity |
Not present |
RBS-1617 |
|||||||
|
– CHOICE DL MAC header type |
MAC-ehs |
RBS-1618 |
|||||||
|
– DL HS-DSCH MAC-ehs Queue Id |
0 |
RBS-1619 |
|||||||
|
– Logical channel identity |
7 |
RBS-1620 |
|||||||
|
– RAB information for setup |
A31, A32 |
Rel-9 |
RBS-1621 |
||||||
|
– RAB info |
(high-speed AM DTCH for PS domain) |
RBS-1622 |
|||||||
|
– RAB identity |
0000 0101B The first/ leftmost bit of the bit string contains the most significant bit of the RAB identity. |
RBS-1623 |
|||||||
|
– CN domain identity |
PS domain |
RBS-1624 |
|||||||
|
– NAS Synchronization Indicator |
Not Present |
RBS-1625 |
|||||||
|
– Re-establishment timer |
useT315 |
RBS-1626 |
|||||||
|
– RB information to setup |
RBS-1627 |
||||||||
|
– RB identity |
25 |
RBS-1628 |
|||||||
|
– PDCP info |
RBS-1629 |
||||||||
|
– Support for lossless SRNS relocation |
FALSE |
RBS-1630 |
|||||||
|
– Max PDCP SN window size |
Not present |
RBS-1631 |
|||||||
|
– PDCP PDU header |
Absent |
RBS-1632 |
|||||||
|
– Header compression information |
Not present |
RBS-1633 |
|||||||
|
– CHOICE RLC info type |
RLC info |
RBS-1634 |
|||||||
|
– CHOICE Uplink RLC mode |
AM RLC |
RBS-1635 |
|||||||
|
– Transmission RLC discard |
RBS-1636 |
||||||||
|
– CHOICE SDU discard mode |
No Discard |
RBS-1637 |
|||||||
|
– MAX_DAT |
15 |
RBS-1638 |
|||||||
|
– Transmission window size |
2047 |
RBS-1639 |
|||||||
|
– Timer_RST |
500 |
RBS-1640 |
|||||||
|
– Max_RST |
4 |
RBS-1641 |
|||||||
|
– Polling info |
RBS-1642 |
||||||||
|
– Timer_poll_prohibit |
100 |
RBS-1643 |
|||||||
|
– Timer_poll |
100 |
RBS-1644 |
|||||||
|
– Poll_PDU |
Not Present |
RBS-1645 |
|||||||
|
– Poll_SDU |
1 |
RBS-1646 |
|||||||
|
– Last transmission PDU poll |
TRUE |
RBS-1647 |
|||||||
|
– Last retransmission PDU poll |
TRUE |
RBS-1648 |
|||||||
|
– Poll_Windows |
50 |
RBS-1649 |
|||||||
|
– Timer_poll_periodic |
Not Present |
RBS-1650 |
|||||||
|
– CHOICE Downlink RLC mode |
AM RLC |
RBS-1651 |
|||||||
|
– CHOICE Downlink RLC PDU Size |
Reference to clause 6 Parameter Set |
RBS-1652 |
|||||||
|
– Length indicator size |
This IE is present and set to “7” if Downlink RLC PDU Size is set to “Flexible” |
RBS-1653 |
|||||||
|
– In-sequence delivery |
TRUE |
RBS-1654 |
|||||||
|
– Receiving window size |
2047 |
RBS-1655 |
|||||||
|
– Downlink RLC status info |
RBS-1656 |
||||||||
|
– Timer_status_prohibit |
80 |
RBS-1657 |
|||||||
|
– Timer_EPC |
Not Present |
RBS-1658 |
|||||||
|
– Missing PDU indicator |
TRUE |
RBS-1659 |
|||||||
|
– Timer_STATUS_periodic |
Not Present |
RBS-1660 |
|||||||
|
– One sided RLC re-establishment |
FALSE |
RBS-1661 |
|||||||
|
– Alternative E-bit interpretation |
Not present |
RBS-1662 |
|||||||
|
– Use special value of HE field |
TRUE |
RBS-1663 |
|||||||
|
– RB mapping info |
RBS-1664 |
||||||||
|
– Information for each multiplexing option |
1 RBMuxOption |
RBS-1665 |
|||||||
|
– RLC logical channel mapping indicator |
Not present |
RBS-1666 |
|||||||
|
– Number of uplink RLC logical channels |
1 |
RBS-1667 |
|||||||
|
– Uplink transport channel type |
E-DCH |
RBS-1668 |
|||||||
|
– Logical channel identity |
7 |
RBS-1669 |
|||||||
|
– E-DCH MAC-d flow identity |
2 |
RBS-1670 |
|||||||
|
– CHOICE RLC PDU size |
Fixed size |
RBS-1671 |
|||||||
|
– DDI |
7 |
RBS-1672 |
|||||||
|
– RLC PDU size list |
See clause 6.10 |
RBS-1673 |
|||||||
|
– Include in scheduling info |
TRUE |
RBS-1674 |
|||||||
|
– MAC logical channel priority |
8 |
RBS-1675 |
|||||||
|
– Downlink RLC logical channel info |
RBS-1676 |
||||||||
|
– Number of downlink RLC logical channels |
1 |
RBS-1677 |
|||||||
|
– Downlink transport channel type |
HS-DSCH |
RBS-1678 |
|||||||
|
– DL DCH Transport channel identity |
Not present |
RBS-1679 |
|||||||
|
– DL DSCH Transport channel identity |
Not present |
RBS-1680 |
|||||||
|
– CHOICE DL MAC header type |
MAC-ehs |
RBS-1681 |
|||||||
|
– DL HS-DSCH MAC-ehs Queue Id |
0 |
RBS-1682 |
|||||||
|
– Logical channel identity |
7 |
RBS-1683 |
|||||||
|
– RAB information for setup |
A33, A34, A35, A36, A37 A38, A39, A40, A41, A42, A43 |
Rel-10 Rel-11 |
RBS-1684 |
||||||
|
– RAB info |
(high-speed AM DTCH for PS domain) |
RBS-1685 |
|||||||
|
– RAB identity |
0000 0101B The first/ leftmost bit of the bit string contains the most significant bit of the RAB identity. |
RBS-1686 |
|||||||
|
– CN domain identity |
PS domain |
RBS-1687 |
|||||||
|
– NAS Synchronization Indicator |
Not Present |
RBS-1688 |
|||||||
|
– Re-establishment timer |
useT315 |
RBS-1689 |
|||||||
|
– RB information to setup |
RBS-1690 |
||||||||
|
– RB identity |
25 |
RBS-1691 |
|||||||
|
– PDCP info |
RBS-1692 |
||||||||
|
– Support for lossless SRNS relocation |
FALSE |
RBS-1693 |
|||||||
|
– Max PDCP SN window size |
Not present |
RBS-1694 |
|||||||
|
– PDCP PDU header |
Absent |
RBS-1695 |
|||||||
|
– Header compression information |
Not present |
RBS-1696 |
|||||||
|
– CHOICE RLC info type |
RLC info |
RBS-1697 |
|||||||
|
– CHOICE Uplink RLC mode |
AM RLC |
RBS-1698 |
|||||||
|
– Transmission RLC discard |
RBS-1699 |
||||||||
|
– CHOICE SDU discard mode |
No Discard |
RBS-1700 |
|||||||
|
– MAX_DAT |
15 |
RBS-1701 |
|||||||
|
– Transmission window size |
2047 |
RBS-1702 |
|||||||
|
– Timer_RST |
500 |
RBS-1703 |
|||||||
|
– Max_RST |
4 |
RBS-1704 |
|||||||
|
– Polling info |
RBS-1705 |
||||||||
|
– Timer_poll_prohibit |
100 |
RBS-1706 |
|||||||
|
– Timer_poll |
100 |
RBS-1707 |
|||||||
|
– Poll_PDU |
Not Present |
RBS-1708 |
|||||||
|
– Poll_SDU |
1 |
RBS-1709 |
|||||||
|
– Last transmission PDU poll |
TRUE |
RBS-1710 |
|||||||
|
– Last retransmission PDU poll |
TRUE |
RBS-1711 |
|||||||
|
– Poll_Windows |
50 |
RBS-1712 |
|||||||
|
– Timer_poll_periodic |
Not Present |
RBS-1713 |
|||||||
|
– CHOICE Downlink RLC mode |
AM RLC |
RBS-1714 |
|||||||
|
– CHOICE Downlink RLC PDU Size |
Reference to clause 6 Parameter Set |
RBS-1715 |
|||||||
|
– Length indicator size |
This IE is present and set to “7” if Downlink RLC PDU Size is set to “Flexible” |
RBS-1716 |
|||||||
|
– In-sequence delivery |
TRUE |
RBS-1717 |
|||||||
|
– Receiving window size |
2047 |
RBS-1718 |
|||||||
|
– Downlink RLC status info |
RBS-1719 |
||||||||
|
– Timer_status_prohibit |
80 |
RBS-1720 |
|||||||
|
– Timer_EPC |
Not Present |
RBS-1721 |
|||||||
|
– Missing PDU indicator |
TRUE |
RBS-1722 |
|||||||
|
– Timer_STATUS_periodic |
Not Present |
RBS-1723 |
|||||||
|
– One sided RLC re-establishment |
FALSE |
RBS-1724 |
|||||||
|
– Alternative E-bit interpretation |
Not present |
RBS-1725 |
|||||||
|
– Use special value of HE field |
TRUE |
RBS-1726 |
|||||||
|
– RB mapping info |
RBS-1727 |
||||||||
|
– Information for each multiplexing option |
1 RBMuxOption |
RBS-1728 |
|||||||
|
– RLC logical channel mapping indicator |
Not present |
RBS-1729 |
|||||||
|
– Number of uplink RLC logical channels |
1 |
RBS-1730 |
|||||||
|
– Uplink transport channel type |
E-DCH |
RBS-1731 |
|||||||
|
– Logical channel identity |
7 |
RBS-1732 |
|||||||
|
– E-DCH MAC-d flow identity |
2 |
RBS-1733 |
|||||||
|
– CHOICE RLC PDU size |
Flexible size |
RBS-1734 |
|||||||
|
– Length indicator size |
15 bit |
RBS-1735 |
|||||||
|
– Minimum UL RLC PDU size |
16 |
RBS-1736 |
|||||||
|
– Largest UL RLC PDU size |
2432 |
RBS-1737 |
|||||||
|
– Include in scheduling info |
TRUE |
RBS-1738 |
|||||||
|
– MAC logical channel priority |
8 |
RBS-1739 |
|||||||
|
– Downlink RLC logical channel info |
RBS-1740 |
||||||||
|
– Number of downlink RLC logical channels |
1 |
RBS-1741 |
|||||||
|
– Downlink transport channel type |
HS-DSCH |
RBS-1742 |
|||||||
|
– DL DCH Transport channel identity |
Not present |
RBS-1743 |
|||||||
|
– DL DSCH Transport channel identity |
Not present |
RBS-1744 |
|||||||
|
– CHOICE DL MAC header type |
MAC-ehs |
RBS-1745 |
|||||||
|
– DL HS-DSCH MAC-ehs Queue Id |
0 |
RBS-1746 |
|||||||
|
– Logical channel identity |
7 |
RBS-1747 |
|||||||
|
– RAB information for setup |
A44, A45 |
Rel-11 |
RBS-1748 |
||||||
|
– RAB info |
(high-speed AM DTCH for PS domain) |
RBS-1749 |
|||||||
|
– RAB identity |
0000 0101B The first/ leftmost bit of the bit string contains the most significant bit of the RAB identity. |
RBS-1750 |
|||||||
|
– CN domain identity |
PS domain |
RBS-1751 |
|||||||
|
– NAS Synchronization Indicator |
Not Present |
RBS-1752 |
|||||||
|
– Re-establishment timer |
useT315 |
RBS-1753 |
|||||||
|
– RB information to setup |
RBS-1754 |
||||||||
|
– RB identity |
25 |
RBS-1755 |
|||||||
|
– PDCP info |
RBS-1756 |
||||||||
|
– Support for lossless SRNS relocation |
FALSE |
RBS-1757 |
|||||||
|
– Max PDCP SN window size |
Not present |
RBS-1758 |
|||||||
|
– PDCP PDU header |
Absent |
RBS-1759 |
|||||||
|
– Header compression information |
Not present |
RBS-1760 |
|||||||
|
– CHOICE RLC info type |
RLC info |
RBS-1761 |
|||||||
|
– CHOICE Uplink RLC mode |
AM RLC |
RBS-1762 |
|||||||
|
– Transmission RLC discard |
RBS-1763 |
||||||||
|
– CHOICE SDU discard mode |
No Discard |
RBS-1764 |
|||||||
|
– MAX_DAT |
15 |
RBS-1765 |
|||||||
|
– Transmission window size |
2047 |
RBS-1766 |
|||||||
|
– Timer_RST |
500 |
RBS-1767 |
|||||||
|
– Max_RST |
4 |
RBS-1768 |
|||||||
|
– Polling info |
RBS-1769 |
||||||||
|
– Timer_poll_prohibit |
100 |
RBS-1770 |
|||||||
|
– Timer_poll |
100 |
RBS-1771 |
|||||||
|
– Poll_PDU |
Not Present |
RBS-1772 |
|||||||
|
– Poll_SDU |
1 |
RBS-1773 |
|||||||
|
– Last transmission PDU poll |
TRUE |
RBS-1774 |
|||||||
|
– Last retransmission PDU poll |
TRUE |
RBS-1775 |
|||||||
|
– Poll_Windows |
50 |
RBS-1776 |
|||||||
|
– Timer_poll_periodic |
Not Present |
RBS-1777 |
|||||||
|
– CHOICE Downlink RLC mode |
AM RLC |
RBS-1778 |
|||||||
|
– CHOICE Downlink RLC PDU Size |
Reference to clause 6 Parameter Set |
RBS-1779 |
|||||||
|
– Length indicator size |
This IE is present and set to “7” if Downlink RLC PDU Size is set to “Flexible” |
RBS-1780 |
|||||||
|
– In-sequence delivery |
TRUE |
RBS-1781 |
|||||||
|
– Receiving window size |
2047 |
RBS-1782 |
|||||||
|
– Downlink RLC status info |
RBS-1783 |
||||||||
|
– Timer_status_prohibit |
80 |
RBS-1784 |
|||||||
|
– Timer_EPC |
Not Present |
RBS-1785 |
|||||||
|
– Missing PDU indicator |
TRUE |
RBS-1786 |
|||||||
|
– Timer_STATUS_periodic – Timer_Reordering |
Not Present 200 |
RBS-1787 |
|||||||
|
– One sided RLC re-establishment |
FALSE |
RBS-1788 |
|||||||
|
– Alternative E-bit interpretation |
Not present |
RBS-1789 |
|||||||
|
– Use special value of HE field |
TRUE |
RBS-1790 |
|||||||
|
– RB mapping info |
RBS-1791 |
||||||||
|
– Information for each multiplexing option |
1 RBMuxOption |
RBS-1792 |
|||||||
|
– RLC logical channel mapping indicator |
Not present |
RBS-1793 |
|||||||
|
– Number of uplink RLC logical channels |
1 |
RBS-1794 |
|||||||
|
– Uplink transport channel type |
E-DCH |
RBS-1795 |
|||||||
|
– Logical channel identity |
7 |
RBS-1796 |
|||||||
|
– E-DCH MAC-d flow identity |
2 |
RBS-1797 |
|||||||
|
– CHOICE RLC PDU size |
Flexible size |
RBS-1798 |
|||||||
|
– Length indicator size |
15 bit |
RBS-1799 |
|||||||
|
– Minimum UL RLC PDU size |
16 |
RBS-1800 |
|||||||
|
– Largest UL RLC PDU size |
2432 |
RBS-1801 |
|||||||
|
– Include in scheduling info |
TRUE |
RBS-1802 |
|||||||
|
– MAC logical channel priority |
8 |
RBS-1803 |
|||||||
|
– Downlink RLC logical channel info |
RBS-1804 |
||||||||
|
– Number of downlink RLC logical channels |
1 |
RBS-1805 |
|||||||
|
– Downlink transport channel type |
HS-DSCH |
RBS-1806 |
|||||||
|
– DL DCH Transport channel identity |
Not present |
RBS-1807 |
|||||||
|
– DL DSCH Transport channel identity |
Not present |
RBS-1808 |
|||||||
|
– CHOICE DL MAC header type |
MAC-ehs |
RBS-1809 |
|||||||
|
– DL HS-DSCH MAC-ehs Queue Id |
0 |
RBS-1810 |
|||||||
|
– Logical channel identity |
7 |
RBS-1811 |
|||||||
|
RB information to reconfigure list |
A1, A2, A3, A4, A5, A6, A7, A8 |
Not Present |
RBS-1812 |
||||||
|
A9, A10 |
Rel-5 |
RBS-1813 |
|||||||
|
A12, A13, A14, A15, A16 |
Rel-6 |
RBS-1814 |
|||||||
|
, A17, A17a, A17f, A18, A19, A19a, A20, A21, A22 |
Rel-7 |
RBS-1815 |
|||||||
|
, A23, A28a |
Rel-7 Rel-8 |
RBS-1816 |
|||||||
|
, A25, A25a, A25b, A26, A27, A27a, A28, A29 |
Rel-8 |
RBS-1817 |
|||||||
|
,A25c, A31, A32 A33, A34, A35, A36, A37 A38, A39, A40, A41, A42, A43, A44, A45 |
Rel-9 Rel-10 Rel-11 |
RBS-1818 |
|||||||
|
RB information to be affected |
A1, A2, A3, A4, A5, A6, A7, A8, A11 |
Not Present |
RBS-1819 |
||||||
|
, A9, A10 |
Rel-5 |
RBS-1820 |
|||||||
|
A12 |
Rel-6 |
RBS-1821 |
|||||||
|
, A17, A17a, A17f, A18, A19, A20, A21, A24 |
Rel-7 |
RBS-1822 |
|||||||
|
, A23 |
Rel-7 Rel-8 |
RBS-1823 |
|||||||
|
, A25a, A28, A29 A35 A38, A39, A40, A41, A42, A43, A44, A45 |
Rel-8 Rel-10 Rel-11 |
RBS-1824 |
|||||||
|
RB information to be affected |
A13, A15 A19a, A25b |
Rel-6 |
RBS-1825 |
||||||
|
, A17d, A17e |
Rel-7 |
RBS-1826 |
|||||||
|
, A26 |
Rel-8 |
RBS-1827 |
|||||||
|
Rel-9 |
RBS-1828 |
||||||||
|
– RB identity |
1 (UM DCCH for RRC) |
RBS-1829 |
|||||||
|
– RB mapping info |
RBS-1830 |
||||||||
|
– Information for each multiplexing option |
1 RBMuxOption |
RBS-1831 |
|||||||
|
– RLC logical channel mapping indicator |
Not Present |
RBS-1832 |
|||||||
|
– Number of uplink RLC logical channels |
1 |
RBS-1833 |
|||||||
|
– Uplink transport channel type |
E-DCH |
RBS-1834 |
|||||||
|
– Logical channel identity |
1 |
RBS-1835 |
|||||||
|
– E-DCH MAC-d flow identity |
1 |
RBS-1836 |
|||||||
|
– CHOICE RLC PDU size |
Fixed size |
Rel-8 |
RBS-1837 |
||||||
|
– DDI |
1 |
RBS-1838 |
|||||||
|
– RLC PDU size list |
1 RLC PDU size |
RBS-1839 |
|||||||
|
– RLC PDU size |
144 bits |
RBS-1840 |
|||||||
|
– Include in scheduling info |
FALSE |
RBS-1841 |
|||||||
|
– MAC logical channel priority |
1 |
RBS-1842 |
|||||||
|
– Downlink RLC logical channel info |
RBS-1843 |
||||||||
|
– Number of RLC logical channels |
1 |
RBS-1844 |
|||||||
|
– Downlink transport channel type |
DCH |
RBS-1845 |
|||||||
|
– DL DCH Transport channel identity |
10 |
RBS-1846 |
|||||||
|
– DL DSCH Transport channel identity |
Not Present |
RBS-1847 |
|||||||
|
– Logical channel identity |
1 |
RBS-1848 |
|||||||
|
– RB identity |
2 (AM DCCH for RRC) |
RBS-1849 |
|||||||
|
– RB mapping info |
RBS-1850 |
||||||||
|
– Information for each multiplexing option |
1 RBMuxOption |
RBS-1851 |
|||||||
|
– RLC logical channel mapping indicator |
Not Present |
RBS-1852 |
|||||||
|
– Number of uplink RLC logical channels |
1 |
RBS-1853 |
|||||||
|
– Uplink transport channel type |
E-DCH |
RBS-1854 |
|||||||
|
– Logical channel identity |
2 |
RBS-1855 |
|||||||
|
– E-DCH MAC-d flow identity |
1 |
RBS-1856 |
|||||||
|
– CHOICE RLC PDU size |
Fixed size |
Rel-8 |
RBS-1857 |
||||||
|
– DDI |
2 |
RBS-1858 |
|||||||
|
– RLC PDU size list |
1 RLC PDU size |
RBS-1859 |
|||||||
|
– RLC PDU size |
144 bits |
RBS-1860 |
|||||||
|
– Include in scheduling info |
FALSE |
RBS-1861 |
|||||||
|
– MAC logical channel priority |
2 |
RBS-1862 |
|||||||
|
– Downlink RLC logical channel info |
RBS-1863 |
||||||||
|
– Number of RLC logical channels |
1 |
RBS-1864 |
|||||||
|
– Downlink transport channel type |
DCH |
RBS-1865 |
|||||||
|
– DL DCH Transport channel identity |
10 |
RBS-1866 |
|||||||
|
– DL DSCH Transport channel identity |
Not Present |
RBS-1867 |
|||||||
|
– Logical channel identity |
2 |
RBS-1868 |
|||||||
|
– RB identity |
3 (AM DCCH for NAS High Priority) |
RBS-1869 |
|||||||
|
– RB mapping info |
RBS-1870 |
||||||||
|
– Information for each multiplexing option |
1 RBMuxOption |
RBS-1871 |
|||||||
|
– RLC logical channel mapping indicator |
Not Present |
RBS-1872 |
|||||||
|
– Number of uplink RLC logical channels |
1 |
RBS-1873 |
|||||||
|
– Uplink transport channel type |
E-DCH |
RBS-1874 |
|||||||
|
– Logical channel identity |
3 |
RBS-1875 |
|||||||
|
– E-DCH MAC-d flow identity |
1 |
RBS-1876 |
|||||||
|
– CHOICE RLC PDU size |
Fixed size |
Rel-8 |
RBS-1877 |
||||||
|
– DDI |
3 |
RBS-1878 |
|||||||
|
– RLC PDU size list |
1 RLC PDU size |
RBS-1879 |
|||||||
|
– RLC PDU size |
144 bits |
RBS-1880 |
|||||||
|
– Include in scheduling info |
FALSE |
RBS-1881 |
|||||||
|
– MAC logical channel priority |
3 |
RBS-1882 |
|||||||
|
– Downlink RLC logical channel info |
RBS-1883 |
||||||||
|
– Number of RLC logical channels |
1 |
RBS-1884 |
|||||||
|
– Downlink transport channel type |
DCH |
RBS-1885 |
|||||||
|
– DL DCH Transport channel identity |
10 |
RBS-1886 |
|||||||
|
– DL DSCH Transport channel identity |
Not Present |
RBS-1887 |
|||||||
|
– Logical channel identity |
3 |
RBS-1888 |
|||||||
|
– RB identity |
4 (AM DCCH for NAS Low Priority) |
RBS-1889 |
|||||||
|
– RB mapping info |
RBS-1890 |
||||||||
|
– Information for each multiplexing option |
1 RBMuxOption |
RBS-1891 |
|||||||
|
– RLC logical channel mapping indicator |
Not Present |
RBS-1892 |
|||||||
|
– Number of uplink RLC logical channels |
1 |
RBS-1893 |
|||||||
|
– Uplink transport channel type |
E-DCH |
RBS-1894 |
|||||||
|
– Logical channel identity |
4 |
RBS-1895 |
|||||||
|
– E-DCH MAC-d flow identity |
1 |
RBS-1896 |
|||||||
|
– CHOICE RLC PDU size |
Fixed size |
Rel-8 |
RBS-1897 |
||||||
|
– DDI |
4 |
RBS-1898 |
|||||||
|
– RLC PDU size list |
1 RLC PDU size |
RBS-1899 |
|||||||
|
– RLC PDU size |
144 bits |
RBS-1900 |
|||||||
|
– Include in scheduling info |
FALSE |
RBS-1901 |
|||||||
|
– MAC logical channel priority |
4 |
RBS-1902 |
|||||||
|
– Downlink RLC logical channel info |
RBS-1903 |
||||||||
|
– Number of RLC logical channels |
1 |
RBS-1904 |
|||||||
|
– Downlink transport channel type |
DCH |
RBS-1905 |
|||||||
|
– DL DCH Transport channel identity |
10 |
RBS-1906 |
|||||||
|
– DL DSCH Transport channel identity |
Not Present |
RBS-1907 |
|||||||
|
– Logical channel identity |
4 |
RBS-1908 |
|||||||
|
RB information to be affected |
A14, A16 , A19b |
Rel-6 Rel-7 |
RBS-1909 |
||||||
|
, A31, A32 |
Rel-9 |
RBS-1910 |
|||||||
|
– RB identity |
1 (UM DCCH for RRC) |
RBS-1911 |
|||||||
|
– RB mapping info |
RBS-1912 |
||||||||
|
– Information for each multiplexing option |
1 RBMuxOption |
RBS-1913 |
|||||||
|
– RLC logical channel mapping indicator |
Not Present |
RBS-1914 |
|||||||
|
– Number of uplink RLC logical channels |
1 |
RBS-1915 |
|||||||
|
– Uplink transport channel type |
E-DCH |
RBS-1916 |
|||||||
|
– Logical channel identity |
1 |
RBS-1917 |
|||||||
|
– E-DCH MAC-d flow identity |
1 |
RBS-1918 |
|||||||
|
– CHOICE RLC PDU size |
Fixed size |
Rel-8 |
RBS-1919 |
||||||
|
– DDI |
1 |
RBS-1920 |
|||||||
|
– RLC PDU size list |
1 RLC PDU size |
RBS-1921 |
|||||||
|
– RLC PDU size |
144 bits |
RBS-1922 |
|||||||
|
– Include in scheduling info |
FALSE |
RBS-1923 |
|||||||
|
– MAC logical channel priority |
1 |
RBS-1924 |
|||||||
|
– Downlink RLC logical channel info |
RBS-1925 |
||||||||
|
– Number of RLC logical channels |
1 |
RBS-1926 |
|||||||
|
– Downlink transport channel type |
HS-DSCH |
RBS-1927 |
|||||||
|
– DL DCH Transport channel identity |
Not present |
RBS-1928 |
|||||||
|
– DL DSCH Transport channel identity |
Not present |
RBS-1929 |
|||||||
|
– DL HS-DSCH MAC-d flow identity |
1 |
RBS-1930 |
|||||||
|
– Logical channel identity |
1 |
RBS-1931 |
|||||||
|
– RB identity |
2 (AM DCCH for RRC) |
RBS-1932 |
|||||||
|
– RB mapping info |
RBS-1933 |
||||||||
|
– Information for each multiplexing option |
1 RBMuxOption |
RBS-1934 |
|||||||
|
– RLC logical channel mapping indicator |
Not Present |
RBS-1935 |
|||||||
|
– Number of uplink RLC logical channels |
1 |
RBS-1936 |
|||||||
|
– Uplink transport channel type |
E-DCH |
RBS-1937 |
|||||||
|
– Logical channel identity |
2 |
RBS-1938 |
|||||||
|
– E-DCH MAC-d flow identity |
1 |
RBS-1939 |
|||||||
|
– CHOICE RLC PDU size |
Fixed size |
Rel-8 |
RBS-1940 |
||||||
|
– DDI |
2 |
RBS-1941 |
|||||||
|
– RLC PDU size list |
1 RLC PDU size |
RBS-1942 |
|||||||
|
– RLC PDU size |
144 bits |
RBS-1943 |
|||||||
|
– Include in scheduling info |
FALSE |
RBS-1944 |
|||||||
|
– MAC logical channel priority |
2 |
RBS-1945 |
|||||||
|
– Downlink RLC logical channel info |
RBS-1946 |
||||||||
|
– Number of RLC logical channels |
1 |
RBS-1947 |
|||||||
|
– Downlink transport channel type |
HS-DSCH |
RBS-1948 |
|||||||
|
– DL DCH Transport channel identity |
Not Present |
RBS-1949 |
|||||||
|
– DL DSCH Transport channel identity |
Not Present |
RBS-1950 |
|||||||
|
– DL HS-DSCH MAC-d flow identity |
1 |
RBS-1951 |
|||||||
|
– Logical channel identity |
2 |
RBS-1952 |
|||||||
|
– RB identity |
3 (AM DCCH for NAS High Priority) |
RBS-1953 |
|||||||
|
– RB mapping info |
RBS-1954 |
||||||||
|
– Information for each multiplexing option |
1 RBMuxOption |
RBS-1955 |
|||||||
|
– RLC logical channel mapping indicator |
Not Present |
RBS-1956 |
|||||||
|
– Number of uplink RLC logical channels |
1 |
RBS-1957 |
|||||||
|
– Uplink transport channel type |
E-DCH |
RBS-1958 |
|||||||
|
– Logical channel identity |
3 |
RBS-1959 |
|||||||
|
– E-DCH MAC-d flow identity |
1 |
RBS-1960 |
|||||||
|
– CHOICE RLC PDU size |
Fixed size |
Rel-8 |
RBS-1961 |
||||||
|
– DDI |
3 |
RBS-1962 |
|||||||
|
– RLC PDU size list |
1 RLC PDU size |
RBS-1963 |
|||||||
|
– RLC PDU size |
144 bits |
RBS-1964 |
|||||||
|
– Include in scheduling info |
FALSE |
RBS-1965 |
|||||||
|
– MAC logical channel priority |
3 |
RBS-1966 |
|||||||
|
– Downlink RLC logical channel info |
RBS-1967 |
||||||||
|
– Number of RLC logical channels |
1 |
RBS-1968 |
|||||||
|
– Downlink transport channel type |
HS-DSCH |
RBS-1969 |
|||||||
|
– DL DCH Transport channel identity |
Not Present |
RBS-1970 |
|||||||
|
– DL DSCH Transport channel identity |
Not Present |
RBS-1971 |
|||||||
|
– DL HS-DSCH MAC-d flow identity |
1 |
RBS-1972 |
|||||||
|
– Logical channel identity |
3 |
RBS-1973 |
|||||||
|
– RB identity |
4 (AM DCCH for NAS Low Priority) |
RBS-1974 |
|||||||
|
– RB mapping info |
RBS-1975 |
||||||||
|
– Information for each multiplexing option |
1 RBMuxOption |
RBS-1976 |
|||||||
|
– RLC logical channel mapping indicator |
Not Present |
RBS-1977 |
|||||||
|
– Number of uplink RLC logical channels |
1 |
RBS-1978 |
|||||||
|
– Uplink transport channel type |
E-DCH |
RBS-1979 |
|||||||
|
– Logical channel identity |
4 |
RBS-1980 |
|||||||
|
– E-DCH MAC-d flow identity |
1 |
RBS-1981 |
|||||||
|
– CHOICE RLC PDU size |
Fixed size |
Rel-8 |
RBS-1982 |
||||||
|
– DDI |
4 |
RBS-1983 |
|||||||
|
– RLC PDU size list |
1 RLC PDU size |
RBS-1984 |
|||||||
|
– RLC PDU size |
144 bits |
RBS-1985 |
|||||||
|
– Include in scheduling info |
FALSE |
RBS-1986 |
|||||||
|
– MAC logical channel priority |
4 |
RBS-1987 |
|||||||
|
– Downlink RLC logical channel info |
RBS-1988 |
||||||||
|
– Number of RLC logical channels |
1 |
RBS-1989 |
|||||||
|
– Downlink transport channel type |
HS-DSCH |
RBS-1990 |
|||||||
|
– DL DCH Transport channel identity |
Not Present |
RBS-1991 |
|||||||
|
– DL DSCH Transport channel identity |
Not Present |
RBS-1992 |
|||||||
|
– DL HS-DSCH MAC-d flow identity |
1 |
RBS-1993 |
|||||||
|
– Logical channel identity |
4 |
RBS-1994 |
|||||||
|
RB information to be affected |
A17b, A17c, A22, A28a |
Rel-7 |
RBS-1995 |
||||||
|
A25 A25c |
Rel-8 Rel-9 |
RBS-1996 |
|||||||
|
– RB identity |
1 (UM DCCH for RRC) |
RBS-1997 |
|||||||
|
– RB mapping info |
RBS-1998 |
||||||||
|
– Information for each multiplexing option |
1 RBMuxOption |
RBS-1999 |
|||||||
|
– RLC logical channel mapping indicator |
Not Present |
RBS-2000 |
|||||||
|
– Number of uplink RLC logical channels |
1 |
RBS-2001 |
|||||||
|
– Uplink transport channel type |
E-DCH |
RBS-2002 |
|||||||
|
– Logical channel identity |
1 |
RBS-2003 |
|||||||
|
– E-DCH MAC-d flow identity |
1 |
RBS-2004 |
|||||||
|
– CHOICE RLC PDU size |
Fixed size |
Rel-8 |
RBS-2005 |
||||||
|
– DDI |
1 |
RBS-2006 |
|||||||
|
– RLC PDU size list |
1 RLC PDU size |
RBS-2007 |
|||||||
|
– RLC PDU size |
144 bits |
RBS-2008 |
|||||||
|
– Include in scheduling info |
FALSE |
RBS-2009 |
|||||||
|
– MAC logical channel priority |
1 |
RBS-2010 |
|||||||
|
– Downlink RLC logical channel info |
RBS-2011 |
||||||||
|
– Number of RLC logical channels |
1 |
RBS-2012 |
|||||||
|
– Downlink transport channel type |
HS-DSCH |
RBS-2013 |
|||||||
|
– DL DCH Transport channel identity |
Not present |
RBS-2014 |
|||||||
|
– DL DSCH Transport channel identity |
Not present |
RBS-2015 |
|||||||
|
– CHOICE DL MAC header type |
MAC-ehs |
RBS-2016 |
|||||||
|
– DL HS-DSCH MAC-ehs Queue Id |
1 |
RBS-2017 |
|||||||
|
– Logical channel identity |
1 |
RBS-2018 |
|||||||
|
– RB identity |
2 (AM DCCH for RRC) |
RBS-2019 |
|||||||
|
– RB mapping info |
RBS-2020 |
||||||||
|
– Information for each multiplexing option |
1 RBMuxOption |
RBS-2021 |
|||||||
|
– RLC logical channel mapping indicator |
Not Present |
RBS-2022 |
|||||||
|
– Number of uplink RLC logical channels |
1 |
RBS-2023 |
|||||||
|
– Uplink transport channel type |
E-DCH |
RBS-2024 |
|||||||
|
– Logical channel identity |
2 |
RBS-2025 |
|||||||
|
– E-DCH MAC-d flow identity |
1 |
RBS-2026 |
|||||||
|
– CHOICE RLC PDU size |
Fixed size |
Rel-8 |
RBS-2027 |
||||||
|
– DDI |
2 |
RBS-2028 |
|||||||
|
– RLC PDU size list |
1 RLC PDU size |
RBS-2029 |
|||||||
|
– RLC PDU size |
144 bits |
RBS-2030 |
|||||||
|
– Include in scheduling info |
FALSE |
RBS-2031 |
|||||||
|
– MAC logical channel priority |
2 |
RBS-2032 |
|||||||
|
– Downlink RLC logical channel info |
RBS-2033 |
||||||||
|
– Number of RLC logical channels |
1 |
RBS-2034 |
|||||||
|
– Downlink transport channel type |
HS-DSCH |
RBS-2035 |
|||||||
|
– DL DCH Transport channel identity |
Not Present |
RBS-2036 |
|||||||
|
– DL DSCH Transport channel identity |
Not Present |
RBS-2037 |
|||||||
|
– CHOICE DL MAC header type |
MAC-ehs |
RBS-2038 |
|||||||
|
– DL HS-DSCH MAC-ehs Queue Id |
1 |
RBS-2039 |
|||||||
|
– Logical channel identity |
2 |
RBS-2040 |
|||||||
|
– RB identity |
3 (AM DCCH for NAS High Priority) |
RBS-2041 |
|||||||
|
– RB mapping info |
RBS-2042 |
||||||||
|
– Information for each multiplexing option |
1 RBMuxOption |
RBS-2043 |
|||||||
|
– RLC logical channel mapping indicator |
Not Present |
RBS-2044 |
|||||||
|
– Number of uplink RLC logical channels |
1 |
RBS-2045 |
|||||||
|
– Uplink transport channel type |
E-DCH |
RBS-2046 |
|||||||
|
– Logical channel identity |
3 |
RBS-2047 |
|||||||
|
– E-DCH MAC-d flow identity |
1 |
RBS-2048 |
|||||||
|
– CHOICE RLC PDU size |
Fixed size |
Rel-8 |
RBS-2049 |
||||||
|
– DDI |
3 |
RBS-2050 |
|||||||
|
– RLC PDU size list |
1 RLC PDU size |
RBS-2051 |
|||||||
|
– RLC PDU size |
144 bits |
RBS-2052 |
|||||||
|
– Include in scheduling info |
FALSE |
RBS-2053 |
|||||||
|
– MAC logical channel priority |
3 |
RBS-2054 |
|||||||
|
– Downlink RLC logical channel info |
RBS-2055 |
||||||||
|
– Number of RLC logical channels |
1 |
RBS-2056 |
|||||||
|
– Downlink transport channel type |
HS-DSCH |
RBS-2057 |
|||||||
|
– DL DCH Transport channel identity |
Not Present |
RBS-2058 |
|||||||
|
– DL DSCH Transport channel identity |
Not Present |
RBS-2059 |
|||||||
|
– CHOICE DL MAC header type |
MAC-ehs |
RBS-2060 |
|||||||
|
– DL HS-DSCH MAC-ehs Queue Id |
1 |
RBS-2061 |
|||||||
|
– Logical channel identity |
3 |
RBS-2062 |
|||||||
|
– RB identity |
4 (AM DCCH for NAS Low Priority) |
RBS-2063 |
|||||||
|
– RB mapping info |
RBS-2064 |
||||||||
|
– Information for each multiplexing option |
1 RBMuxOption |
RBS-2065 |
|||||||
|
– RLC logical channel mapping indicator |
Not Present |
RBS-2066 |
|||||||
|
– Number of uplink RLC logical channels |
1 |
RBS-2067 |
|||||||
|
– Uplink transport channel type |
E-DCH |
RBS-2068 |
|||||||
|
– Logical channel identity |
4 |
RBS-2069 |
|||||||
|
– E-DCH MAC-d flow identity |
1 |
RBS-2070 |
|||||||
|
– CHOICE RLC PDU size |
Fixed size |
Rel-8 |
RBS-2071 |
||||||
|
– DDI |
4 |
RBS-2072 |
|||||||
|
– RLC PDU size list |
1 RLC PDU size |
RBS-2073 |
|||||||
|
– RLC PDU size |
144 bits |
RBS-2074 |
|||||||
|
– Include in scheduling info |
FALSE |
RBS-2075 |
|||||||
|
– MAC logical channel priority |
4 |
RBS-2076 |
|||||||
|
– Downlink RLC logical channel info |
RBS-2077 |
||||||||
|
– Number of RLC logical channels |
1 |
RBS-2078 |
|||||||
|
– Downlink transport channel type |
HS-DSCH |
RBS-2079 |
|||||||
|
– DL DCH Transport channel identity |
Not Present |
RBS-2080 |
|||||||
|
– DL DSCH Transport channel identity |
Not Present |
RBS-2081 |
|||||||
|
– CHOICE DL MAC header type |
MAC-ehs |
RBS-2082 |
|||||||
|
– DL HS-DSCH MAC-ehs Queue Id |
1 |
RBS-2083 |
|||||||
|
– Logical channel identity |
4 |
RBS-2084 |
|||||||
|
RB information to be affected |
A27, A27a , A33, A34, A36, A37 |
Rel-8 Rel-10 |
RBS-2085 |
||||||
|
– RB identity |
1 (UM DCCH for RRC) |
RBS-2086 |
|||||||
|
– RB mapping info |
RBS-2087 |
||||||||
|
– Information for each multiplexing option |
1 RBMuxOption |
RBS-2088 |
|||||||
|
– RLC logical channel mapping indicator |
Not Present |
RBS-2089 |
|||||||
|
– Number of uplink RLC logical channels |
1 |
RBS-2090 |
|||||||
|
– Uplink transport channel type |
E-DCH |
RBS-2091 |
|||||||
|
– Logical channel identity |
1 |
RBS-2092 |
|||||||
|
– E-DCH MAC-d flow identity |
1 |
RBS-2093 |
|||||||
|
– CHOICE RLC PDU size |
Fixed size |
RBS-2094 |
|||||||
|
– DDI |
Not Present |
RBS-2095 |
|||||||
|
– RLC PDU size list |
1 RLC PDU size |
RBS-2096 |
|||||||
|
– RLC PDU size |
144 bits |
RBS-2097 |
|||||||
|
– Include in scheduling info |
FALSE |
RBS-2098 |
|||||||
|
– MAC logical channel priority |
1 |
RBS-2099 |
|||||||
|
– Downlink RLC logical channel info |
RBS-2100 |
||||||||
|
– Number of RLC logical channels |
1 |
RBS-2101 |
|||||||
|
– Downlink transport channel type |
HS-DSCH |
RBS-2102 |
|||||||
|
– DL DCH Transport channel identity |
Not present |
RBS-2103 |
|||||||
|
– DL DSCH Transport channel identity |
Not present |
RBS-2104 |
|||||||
|
– CHOICE DL MAC header type |
MAC-ehs |
RBS-2105 |
|||||||
|
– DL HS-DSCH MAC-ehs Queue Id |
1 |
RBS-2106 |
|||||||
|
– Logical channel identity |
1 |
RBS-2107 |
|||||||
|
– RB identity |
2 (AM DCCH for RRC) |
RBS-2108 |
|||||||
|
– RB mapping info |
RBS-2109 |
||||||||
|
– Information for each multiplexing option |
1 RBMuxOption |
RBS-2110 |
|||||||
|
– RLC logical channel mapping indicator |
Not Present |
RBS-2111 |
|||||||
|
– Number of uplink RLC logical channels |
1 |
RBS-2112 |
|||||||
|
– Uplink transport channel type |
E-DCH |
RBS-2113 |
|||||||
|
– Logical channel identity |
2 |
RBS-2114 |
|||||||
|
– E-DCH MAC-d flow identity |
1 |
RBS-2115 |
|||||||
|
– CHOICE RLC PDU size |
Fixed size |
RBS-2116 |
|||||||
|
– DDI |
Not Present |
RBS-2117 |
|||||||
|
– RLC PDU size list |
1 RLC PDU size |
RBS-2118 |
|||||||
|
– RLC PDU size |
144 bits |
RBS-2119 |
|||||||
|
– Include in scheduling info |
FALSE |
RBS-2120 |
|||||||
|
– MAC logical channel priority |
2 |
RBS-2121 |
|||||||
|
– Downlink RLC logical channel info |
RBS-2122 |
||||||||
|
– Number of RLC logical channels |
1 |
RBS-2123 |
|||||||
|
– Downlink transport channel type |
HS-DSCH |
RBS-2124 |
|||||||
|
– DL DCH Transport channel identity |
Not Present |
RBS-2125 |
|||||||
|
– DL DSCH Transport channel identity |
Not Present |
RBS-2126 |
|||||||
|
– CHOICE DL MAC header type |
MAC-ehs |
RBS-2127 |
|||||||
|
– DL HS-DSCH MAC-ehs Queue Id |
1 |
RBS-2128 |
|||||||
|
– Logical channel identity |
2 |
RBS-2129 |
|||||||
|
– RB identity |
3 (AM DCCH for NAS High Priority) |
RBS-2130 |
|||||||
|
– RB mapping info |
RBS-2131 |
||||||||
|
– Information for each multiplexing option |
1 RBMuxOption |
RBS-2132 |
|||||||
|
– RLC logical channel mapping indicator |
Not Present |
RBS-2133 |
|||||||
|
– Number of uplink RLC logical channels |
1 |
RBS-2134 |
|||||||
|
– Uplink transport channel type |
E-DCH |
RBS-2135 |
|||||||
|
– Logical channel identity |
3 |
RBS-2136 |
|||||||
|
– E-DCH MAC-d flow identity |
1 |
RBS-2137 |
|||||||
|
– CHOICE RLC PDU size |
Fixed size |
RBS-2138 |
|||||||
|
– DDI |
Not Present |
RBS-2139 |
|||||||
|
– RLC PDU size list |
1 RLC PDU size |
RBS-2140 |
|||||||
|
– RLC PDU size |
144 bits |
RBS-2141 |
|||||||
|
– Include in scheduling info |
FALSE |
RBS-2142 |
|||||||
|
– MAC logical channel priority |
3 |
RBS-2143 |
|||||||
|
– Downlink RLC logical channel info |
RBS-2144 |
||||||||
|
– Number of RLC logical channels |
1 |
RBS-2145 |
|||||||
|
– Downlink transport channel type |
HS-DSCH |
RBS-2146 |
|||||||
|
– DL DCH Transport channel identity |
Not Present |
RBS-2147 |
|||||||
|
– DL DSCH Transport channel identity |
Not Present |
RBS-2148 |
|||||||
|
– CHOICE DL MAC header type |
MAC-ehs |
RBS-2149 |
|||||||
|
– DL HS-DSCH MAC-ehs Queue Id |
1 |
RBS-2150 |
|||||||
|
– Logical channel identity |
3 |
RBS-2151 |
|||||||
|
– RB identity |
4 (AM DCCH for NAS Low Priority) |
RBS-2152 |
|||||||
|
– RB mapping info |
RBS-2153 |
||||||||
|
– Information for each multiplexing option |
1 RBMuxOption |
RBS-2154 |
|||||||
|
– RLC logical channel mapping indicator |
Not Present |
RBS-2155 |
|||||||
|
– Number of uplink RLC logical channels |
1 |
RBS-2156 |
|||||||
|
– Uplink transport channel type |
E-DCH |
RBS-2157 |
|||||||
|
– Logical channel identity |
4 |
RBS-2158 |
|||||||
|
– E-DCH MAC-d flow identity |
1 |
RBS-2159 |
|||||||
|
– CHOICE RLC PDU size |
Fixed size |
RBS-2160 |
|||||||
|
– DDI |
Not Present |
RBS-2161 |
|||||||
|
– RLC PDU size list |
1 RLC PDU size |
RBS-2162 |
|||||||
|
– RLC PDU size |
144 bits |
RBS-2163 |
|||||||
|
– Include in scheduling info |
FALSE |
RBS-2164 |
|||||||
|
– MAC logical channel priority |
4 |
RBS-2165 |
|||||||
|
– Downlink RLC logical channel info |
RBS-2166 |
||||||||
|
– Number of RLC logical channels |
1 |
RBS-2167 |
|||||||
|
– Downlink transport channel type |
HS-DSCH |
RBS-2168 |
|||||||
|
– DL DCH Transport channel identity |
Not Present |
RBS-2169 |
|||||||
|
– DL DSCH Transport channel identity |
Not Present |
RBS-2170 |
|||||||
|
– CHOICE DL MAC header type |
MAC-ehs |
RBS-2171 |
|||||||
|
– DL HS-DSCH MAC-ehs Queue Id |
1 |
RBS-2172 |
|||||||
|
– Logical channel identity |
4 |
RBS-2173 |
|||||||
|
RB information to be affected |
A30 |
Rel-8 |
RBS-2174 |
||||||
|
– RB identity |
1 (UM DCCH for RRC) |
RBS-2175 |
|||||||
|
– RB mapping info |
RBS-2176 |
||||||||
|
– Information for each multiplexing option |
1 RBMuxOption |
RBS-2177 |
|||||||
|
– RLC logical channel mapping indicator |
Not Present |
RBS-2178 |
|||||||
|
– Number of uplink RLC logical channels |
1 |
RBS-2179 |
|||||||
|
– Uplink transport channel type |
E-DCH |
RBS-2180 |
|||||||
|
– Logical channel identity |
1 |
RBS-2181 |
|||||||
|
– E-DCH MAC-d flow identity |
3 |
RBS-2182 |
|||||||
|
– CHOICE RLC PDU size |
Fixed size |
RBS-2183 |
|||||||
|
– DDI |
0 (Not applicable for MAC-i/is) |
RBS-2184 |
|||||||
|
– RLC PDU size list |
1 RLC PDU size |
RBS-2185 |
|||||||
|
– RLC PDU size |
144 bits |
RBS-2186 |
|||||||
|
– Include in scheduling info |
FALSE |
RBS-2187 |
|||||||
|
– MAC logical channel priority |
1 |
RBS-2188 |
|||||||
|
– Downlink RLC logical channel info |
RBS-2189 |
||||||||
|
– Number of RLC logical channels |
1 |
RBS-2190 |
|||||||
|
– Downlink transport channel type |
HS-DSCH |
RBS-2191 |
|||||||
|
– DL DCH Transport channel identity |
Not present |
RBS-2192 |
|||||||
|
– DL DSCH Transport channel identity |
Not present |
RBS-2193 |
|||||||
|
– CHOICE DL MAC header type |
MAC-ehs |
RBS-2194 |
|||||||
|
– DL HS-DSCH MAC-ehs Queue Id |
3 |
RBS-2195 |
|||||||
|
– Logical channel identity |
1 |
RBS-2196 |
|||||||
|
– RB identity |
2 (AM DCCH for RRC) |
RBS-2197 |
|||||||
|
– RB mapping info |
RBS-2198 |
||||||||
|
– Information for each multiplexing option |
1 RBMuxOption |
RBS-2199 |
|||||||
|
– RLC logical channel mapping indicator |
Not Present |
RBS-2200 |
|||||||
|
– Number of uplink RLC logical channels |
1 |
RBS-2201 |
|||||||
|
– Uplink transport channel type |
E-DCH |
RBS-2202 |
|||||||
|
– Logical channel identity |
2 |
RBS-2203 |
|||||||
|
– E-DCH MAC-d flow identity |
3 |
RBS-2204 |
|||||||
|
– CHOICE RLC PDU size |
Fixed size |
RBS-2205 |
|||||||
|
– DDI |
0 (Not applicable for MAC-i/is) |
RBS-2206 |
|||||||
|
– RLC PDU size list |
1 RLC PDU size |
RBS-2207 |
|||||||
|
– RLC PDU size |
144 bits |
RBS-2208 |
|||||||
|
– Include in scheduling info |
FALSE |
RBS-2209 |
|||||||
|
– MAC logical channel priority |
2 |
RBS-2210 |
|||||||
|
– Downlink RLC logical channel info |
RBS-2211 |
||||||||
|
– Number of RLC logical channels |
1 |
RBS-2212 |
|||||||
|
– Downlink transport channel type |
HS-DSCH |
RBS-2213 |
|||||||
|
– DL DCH Transport channel identity |
Not Present |
RBS-2214 |
|||||||
|
– DL DSCH Transport channel identity |
Not Present |
RBS-2215 |
|||||||
|
– CHOICE DL MAC header type |
MAC-ehs |
RBS-2216 |
|||||||
|
– DL HS-DSCH MAC-ehs Queue Id |
3 |
RBS-2217 |
|||||||
|
– Logical channel identity |
2 |
RBS-2218 |
|||||||
|
– RB identity |
3 (AM DCCH for NAS High Priority) |
RBS-2219 |
|||||||
|
– RB mapping info |
RBS-2220 |
||||||||
|
– Information for each multiplexing option |
1 RBMuxOption |
RBS-2221 |
|||||||
|
– RLC logical channel mapping indicator |
Not Present |
RBS-2222 |
|||||||
|
– Number of uplink RLC logical channels |
1 |
RBS-2223 |
|||||||
|
– Uplink transport channel type |
E-DCH |
RBS-2224 |
|||||||
|
– Logical channel identity |
3 |
RBS-2225 |
|||||||
|
– E-DCH MAC-d flow identity |
3 |
RBS-2226 |
|||||||
|
– CHOICE RLC PDU size |
Fixed size |
Rel-8 |
RBS-2227 |
||||||
|
– DDI |
0 (Not applicable for MAC-i/is) |
RBS-2228 |
|||||||
|
– RLC PDU size list |
1 RLC PDU size |
RBS-2229 |
|||||||
|
– RLC PDU size |
144 bits |
RBS-2230 |
|||||||
|
– Include in scheduling info |
FALSE |
RBS-2231 |
|||||||
|
– MAC logical channel priority |
3 |
RBS-2232 |
|||||||
|
– Downlink RLC logical channel info |
RBS-2233 |
||||||||
|
– Number of RLC logical channels |
1 |
RBS-2234 |
|||||||
|
– Downlink transport channel type |
HS-DSCH |
RBS-2235 |
|||||||
|
– DL DCH Transport channel identity |
Not Present |
RBS-2236 |
|||||||
|
– DL DSCH Transport channel identity |
Not Present |
RBS-2237 |
|||||||
|
– CHOICE DL MAC header type |
MAC-ehs |
RBS-2238 |
|||||||
|
– DL HS-DSCH MAC-ehs Queue Id |
3 |
RBS-2239 |
|||||||
|
– Logical channel identity |
3 |
RBS-2240 |
|||||||
|
– RB identity |
4 (AM DCCH for NAS Low Priority) |
RBS-2241 |
|||||||
|
– RB mapping info |
RBS-2242 |
||||||||
|
– Information for each multiplexing option |
1 RBMuxOption |
RBS-2243 |
|||||||
|
– RLC logical channel mapping indicator |
Not Present |
RBS-2244 |
|||||||
|
– Number of uplink RLC logical channels |
1 |
RBS-2245 |
|||||||
|
– Uplink transport channel type |
E-DCH |
RBS-2246 |
|||||||
|
– Logical channel identity |
4 |
RBS-2247 |
|||||||
|
– E-DCH MAC-d flow identity |
3 |
RBS-2248 |
|||||||
|
– CHOICE RLC PDU size |
Fixed size |
Rel-8 |
RBS-2249 |
||||||
|
– DDI |
4 |
RBS-2250 |
|||||||
|
– RLC PDU size list |
1 RLC PDU size |
RBS-2251 |
|||||||
|
– RLC PDU size |
144 bits |
RBS-2252 |
|||||||
|
– Include in scheduling info |
FALSE |
RBS-2253 |
|||||||
|
– MAC logical channel priority |
4 |
RBS-2254 |
|||||||
|
– Downlink RLC logical channel info |
RBS-2255 |
||||||||
|
– Number of RLC logical channels |
1 |
RBS-2256 |
|||||||
|
– Downlink transport channel type |
HS-DSCH |
RBS-2257 |
|||||||
|
– DL DCH Transport channel identity |
Not Present |
RBS-2258 |
|||||||
|
– DL DSCH Transport channel identity |
Not Present |
RBS-2259 |
|||||||
|
– CHOICE DL MAC header type |
MAC-ehs |
RBS-2260 |
|||||||
|
– DL HS-DSCH MAC-ehs Queue Id |
3 |
RBS-2261 |
|||||||
|
– Logical channel identity |
4 |
RBS-2262 |
|||||||
|
Downlink counter synchronization info |
A1, A2, A3, A4, A5, A6, A7, A8, A11 |
Not Present |
|
RBS-2263 |
|||||
|
, A9, A10 |
Rel-5 |
RBS-2264 |
|||||||
|
, A12, A13, A14, A15, A16 |
Rel-6 |
RBS-2265 |
|||||||
|
, A17, A17a, A17b, A17c, A17d, A17e, A17f, A18, A19, A19a, A19b, A20, A21, A22, A24 |
Rel-7 |
RBS-2266 |
|||||||
|
, A23, A28a |
Rel-7 Rel-8 |
RBS-2267 |
|||||||
|
, A25, A25a, A25b, A26, A27, A27a, A28, A29, A30 |
Rel-8 |
RBS-2268 |
|||||||
|
, A31, A32, A25c , A33, A34, A35, A36, A37 A38, A39, A40, A41, A42, A43, A44, A45 |
Rel-9 Rel-10 Rel-11 |
RBS-2269 |
|||||||
|
PDCP ROHC target mode |
A9, A10 |
Not Present |
Rel-5 |
RBS-2270 |
|||||
|
, A12, A13, A14, A15, A16 |
Rel-6 |
RBS-2271 |
|||||||
|
, A17, A17a, A17b, A17c, A17d, A17e, A17f, A18, A19, A19a, A19b, A20, A21, A22, A24 |
Rel-7 |
RBS-2272 |
|||||||
|
, A23, A28a |
Rel-7 Rel-8 |
RBS-2273 |
|||||||
|
, A25, A25a, A25b, A26, A27, A27a, A28, A29, A30 |
Rel-8 |
RBS-2274 |
|||||||
|
, A31, A32, A25c , A33, A34, A35, A36, A37 A38, A39, A40, A41, A42, A43, A44, A45 |
Rel-9 Rel-10 Rel-11 |
RBS-2275 |
|||||||
|
UL Transport channel information for all transport channels |
A1, A2, A3, A4, A5, A6, A7, A8, A11 |
|
RBS-2276 |
||||||
|
, A9, A10 |
Rel-5 |
RBS-2277 |
|||||||
|
, A17, A17a, A17f, A18 |
Rel-7 |
RBS-2278 |
|||||||
|
, A25a, A28 |
Rel-8 |
RBS-2279 |
|||||||
|
, A31, A32 , A33, A34, A35, A36, A37 A38, A39, A40, A41, A42, A43, A44, A45 |
Rel-9 Rel-10 Rel-11 |
RBS-2280 |
|||||||
|
– PRACH TFCS |
Not Present |
RBS-2281 |
|||||||
|
– CHOICE mode |
FDD |
RBS-2282 |
|||||||
|
– TFC subset |
Not Present |
RBS-2283 |
|||||||
|
– UL DCH TFCS |
|
RBS-2284 |
|||||||
|
– CHOICE TFCI signalling |
Normal |
RBS-2285 |
|||||||
|
– TFCI Field 1 information |
|
RBS-2286 |
|||||||
|
– CHOICE TFCS representation |
Complete reconfiguration |
RBS-2287 |
|||||||
|
– TFCS complete reconfigure information |
|
RBS-2288 |
|||||||
|
– CHOICE CTFC Size |
Number of bits used must be enough to cover all combinations of CTFC from clause 6.10.2.4 Parameter Set. |
RBS-2289 |
|||||||
|
– CTFC information |
This IE is repeated for TFC numbers and reference to clause 6.10.2.4 Parameter Set |
RBS-2290 |
|||||||
|
– CTFC |
Reference to clause 6.10.2.4 Parameter Set |
RBS-2291 |
|||||||
|
– Power offset information |
|
RBS-2292 |
|||||||
|
– CHOICE Gain Factors |
Computed Gain Factors(The last TFC is set to Signalled Gain Factors) |
RBS-2293 |
|||||||
|
– Gain factor βc |
11 (below 64 kbps) 9 (equal or higher than 64 kbps) when HSDPA is not configured 9 (equal or higher than 64 kbps and below 384 kbps) when HSDPA is also configured 6 (equal or higher than 384 kbps) when HSDPA is also configured (Not Present if the CHOICE Gain Factors is set to Computed Gain Factors) |
RBS-2294 |
|||||||
|
– Gain factor βd |
15 (Not Present if the CHOICE Gain Factors is set to Computed Gain Factors) |
RBS-2295 |
|||||||
|
– Reference TFC ID |
0 |
RBS-2296 |
|||||||
|
– CHOICE mode |
FDD |
RBS-2297 |
|||||||
|
– Power offset P p-m |
Not Present |
RBS-2298 |
|||||||
|
UL Transport channel information for all transport channels |
A12, |
Rel-6 |
RBS-2299 |
||||||
|
A19 |
Rel-7 |
RBS-2300 |
|||||||
|
– PRACH TFCS |
Not Present |
RBS-2301 |
|||||||
|
– CHOICE mode |
FDD |
RBS-2302 |
|||||||
|
– TFC subset |
Not Present |
RBS-2303 |
|||||||
|
– UL DCH TFCS |
RBS-2304 |
||||||||
|
– CHOICE TFCI signalling |
Normal |
RBS-2305 |
|||||||
|
– TFCI Field 1 information |
RBS-2306 |
||||||||
|
– CHOICE TFCS representation |
Complete reconfiguration |
RBS-2307 |
|||||||
|
– TFCS complete reconfigure information |
RBS-2308 |
||||||||
|
– CHOICE CTFC Size |
ctfc2bit |
RBS-2309 |
|||||||
|
– CTFC information |
RBS-2310 |
||||||||
|
– CTFC |
0 ((UL DCH RAB, DCCH)=(TF0, TF0)) |
RBS-2311 |
|||||||
|
– Power offset information |
RBS-2312 |
||||||||
|
– CHOICE Gain Factors |
Computed Gain Factors |
RBS-2313 |
|||||||
|
– CTFC |
1 ((UL DCH RAB, DCCH)=(TF0, TF1)) |
RBS-2314 |
|||||||
|
– Power offset information |
RBS-2315 |
||||||||
|
– CHOICE Gain Factors |
Signalled Gain Factors |
RBS-2316 |
|||||||
|
– Gain factor βc |
11 (below 64 kbps) 9 (equal or higher than 64 kbps) when HSDPA is not configured 9 (equal or higher than 64 kbps and below 384 kbps) when HSDPA is also configured 6 (equal or higher than 384 kbps) when HSDPA is also configured (Not Present if the CHOICE Gain Factors is set to Computed Gain Factors) |
RBS-2317 |
|||||||
|
– Gain factor βd |
15 |
RBS-2318 |
|||||||
|
– Reference TFC ID |
0 |
RBS-2319 |
|||||||
|
– CHOICE mode |
FDD |
RBS-2320 |
|||||||
|
– Power offset P p-m |
Not Present |
RBS-2321 |
|||||||
|
UL Transport channel information for all transport channels |
A13, A14, A15, A16 |
Not Present |
Rel-6 |
RBS-2322 |
|||||
|
, A17b, A17c, A17d, A17e, A19a, A19b, A20, A21, A22, A24 |
Rel-7 |
RBS-2323 |
|||||||
|
, A23, A28a, |
Rel-7 Rel-8 |
RBS-2324 |
|||||||
|
, A25, A25b, A26, A27, A27a, A29, A30 |
Rel-8 |
RBS-2325 |
|||||||
|
, A25c |
Rel-9 |
RBS-2326 |
|||||||
|
Deleted UL TrCH information |
A1, A2, A3, A4, A5, A6, A7, A8, A11 |
Not Present |
RBS-2327 |
||||||
|
, A9, A10 |
Rel-5 |
RBS-2328 |
|||||||
|
, A12 |
Rel-6 |
RBS-2329 |
|||||||
|
, A17, A17a, A17f, A18, A19, A20, A21, A24 |
Rel-7 |
RBS-2330 |
|||||||
|
, A23, |
Rel-7 Rel-8 |
RBS-2331 |
|||||||
|
, A28, A29 |
Rel-8 |
RBS-2332 |
|||||||
|
A35, A37 A38, A39, A40, A41, A42, A43, A44, A45 |
Rel-10 Rel-11 |
RBS-2333 |
|||||||
|
Deleted UL TrCH information |
A13, A14, A15, A16 |
Rel-6 |
RBS-2334 |
||||||
|
A17b, A17c, A17d, A17e, A19a, A19b, A22, A26, A27, A27a, A28a |
Rel-7 |
RBS-2335 |
|||||||
|
A25, A25b |
Rel-8 |
RBS-2336 |
|||||||
|
, A25c, A31, A32 , A33, A34, A36, A37 |
Rel-9 Rel-10 |
RBS-2337 |
|||||||
|
– Uplink transport channel type |
DCH |
RBS-2338 |
|||||||
|
– UL transport channel identity |
5 |
RBS-2339 |
|||||||
|
Deleted UL TrCH information – Uplink transport channel type – E-DCH MAC-d flow identity |
A30 |
e_dch 1 |
Rel-8 |
RBS-2339a |
|||||
|
Added or Reconfigured UL TrCH information |
A1, A3 A4, A5, A6, A7 |
1 DCH added, 1 DCH reconfigured (if from cell_DCH) OR 2 DCHs added (if from cell_FACH) |
RBS-2340 |
||||||
|
, A9, A10 |
Rel-5 |
RBS-2341 |
|||||||
|
, A17, A17a, A18, |
Rel-7 |
RBS-2342 |
|||||||
|
, A28 |
Rel-8 |
RBS-2343 |
|||||||
|
– Uplink transport channel type |
DCH |
RBS-2344 |
|||||||
|
– UL Transport channel identity |
1 |
RBS-2345 |
|||||||
|
– TFS |
RBS-2346 |
||||||||
|
– CHOICE Transport channel type |
Dedicated transport channels |
RBS-2347 |
|||||||
|
– Dynamic Transport format information |
RBS-2348 |
||||||||
|
– RLC Size |
Reference to clause 6.10 Parameter Set |
RBS-2349 |
|||||||
|
– Number of TBs and TTI List |
(This IE is repeated for TFI number.) |
RBS-2350 |
|||||||
|
– Transmission Time Interval |
Not Present |
RBS-2351 |
|||||||
|
– Number of Transport blocks |
Reference to clause 6.10 Parameter Set |
RBS-2352 |
|||||||
|
– CHOICE Logical channel list |
All |
RBS-2353 |
|||||||
|
– Semi-static Transport Format information |
RBS-2354 |
||||||||
|
– Transmission time interval |
Reference to clause 6.10 Parameter Set |
RBS-2355 |
|||||||
|
– Type of channel coding |
Reference to clause 6.10 Parameter Set |
RBS-2356 |
|||||||
|
– Coding Rate |
Reference to clause 6.10 Parameter Set |
RBS-2357 |
|||||||
|
– Rate matching attribute |
Reference to clause 6.10 Parameter Set |
RBS-2358 |
|||||||
|
– CRC size |
Reference to clause 6.10 Parameter Set |
RBS-2359 |
|||||||
|
– Uplink transport channel type |
DCH |
RBS-2360 |
|||||||
|
– UL Transport channel identity |
5 |
RBS-2361 |
|||||||
|
– TFS |
RBS-2362 |
||||||||
|
– CHOICE Transport channel type |
Dedicated transport channels |
RBS-2363 |
|||||||
|
– Dynamic Transport format information |
RBS-2364 |
||||||||
|
– RLC Size |
Reference to clause 6.10 Parameter Set |
RBS-2365 |
|||||||
|
– Number of TBs and TTI List |
(This IE is repeated for TFI number.) |
RBS-2366 |
|||||||
|
– Transmission Time Interval |
Not Present |
RBS-2367 |
|||||||
|
– Number of Transport blocks |
Reference to clause 6.10 Parameter Set |
RBS-2368 |
|||||||
|
– CHOICE Logical channel list |
All |
RBS-2369 |
|||||||
|
– Semi-static Transport Format information |
RBS-2370 |
||||||||
|
– Transmission time interval |
Reference to clause 6.10 Parameter Set |
RBS-2371 |
|||||||
|
– Type of channel coding |
Reference to clause 6.10 Parameter Set |
RBS-2372 |
|||||||
|
– Coding Rate |
Reference to clause 6.10 Parameter Set |
RBS-2373 |
|||||||
|
– Rate matching attribute |
Reference to clause 6.10 Parameter Set |
RBS-2374 |
|||||||
|
– CRC size |
Reference to clause 6.10 Parameter Set |
RBS-2375 |
|||||||
|
Added or Reconfigured UL TrCH information |
A11 |
1 DCH added for DTCH |
RBS-2376 |
||||||
|
– Uplink transport channel type |
DCH |
RBS-2377 |
|||||||
|
– UL Transport channel identity |
4 |
RBS-2378 |
|||||||
|
– TFS |
RBS-2379 |
||||||||
|
– CHOICE Transport channel type |
Dedicated transport channels |
RBS-2380 |
|||||||
|
– Dynamic Transport format information |
RBS-2381 |
||||||||
|
– RLC Size |
Reference to clause 6.10 Parameter Set |
RBS-2382 |
|||||||
|
– Number of TBs and TTI List |
(This IE is repeated for TFI number.) |
RBS-2383 |
|||||||
|
– Transmission Time Interval |
Not Present |
RBS-2384 |
|||||||
|
– Number of Transport blocks |
Reference to clause 6.10 Parameter Set |
RBS-2385 |
|||||||
|
– CHOICE Logical channel list |
All |
RBS-2386 |
|||||||
|
– Semi-static Transport Format information |
RBS-2387 |
||||||||
|
– Transmission time interval |
Reference to clause 6.10 Parameter Set |
RBS-2388 |
|||||||
|
– Type of channel coding |
Reference to clause 6.10 Parameter Set |
RBS-2389 |
|||||||
|
– Coding Rate |
Reference to clause 6.10 Parameter Set |
RBS-2390 |
|||||||
|
– Rate matching attribute |
Reference to clause 6.10 Parameter Set |
RBS-2391 |
|||||||
|
– CRC size |
Reference to clause 6.10 Parameter Set |
RBS-2392 |
|||||||
|
Added or Reconfigured UL TrCH information |
A2, A8 |
4 TrCHs(DCH for DCCH and 3DCHs for DTCH) |
RBS-2393 |
||||||
|
– Uplink transport channel type |
DCH |
RBS-2394 |
|||||||
|
– UL Transport channel identity |
5 |
RBS-2395 |
|||||||
|
– TFS |
RBS-2396 |
||||||||
|
– CHOICE Transport channel type |
Dedicated transport channels |
RBS-2397 |
|||||||
|
– Dynamic Transport format information |
RBS-2398 |
||||||||
|
– RLC Size |
Reference to clause 6.10 Parameter Set |
RBS-2399 |
|||||||
|
– Number of TBs and TTI List |
(This IE is repeated for TFI number.) |
RBS-2400 |
|||||||
|
– Transmission Time Interval |
Not Present |
RBS-2401 |
|||||||
|
– Number of Transport blocks |
Reference to clause 6.10 Parameter Set |
RBS-2402 |
|||||||
|
– CHOICE Logical channel list |
All |
RBS-2403 |
|||||||
|
– Semi-static Transport Format information |
RBS-2404 |
||||||||
|
– Transmission time interval |
Reference to clause 6.10 Parameter Set |
RBS-2405 |
|||||||
|
– Type of channel coding |
Reference to clause 6.10 Parameter Set |
RBS-2406 |
|||||||
|
– Coding Rate |
Reference to clause 6.10 Parameter Set |
RBS-2407 |
|||||||
|
– Rate matching attribute |
Reference to clause 6.10 Parameter Set |
RBS-2408 |
|||||||
|
– CRC size |
Reference to clause 6.10 Parameter Set |
RBS-2409 |
|||||||
|
– Uplink transport channel type |
DCH |
RBS-2410 |
|||||||
|
– UL Transport channel identity |
1 |
RBS-2411 |
|||||||
|
– TFS |
RBS-2412 |
||||||||
|
– CHOICE Transport channel type |
Dedicated transport channels |
RBS-2413 |
|||||||
|
– Dynamic Transport format information |
|
RBS-2414 |
|||||||
|
– RLC Size |
Reference to clause 6.10 Parameter Set |
RBS-2415 |
|||||||
|
– Number of TBs and TTI List |
(This IE is repeated for TFI number.) |
RBS-2416 |
|||||||
|
– Transmission Time Interval |
Not Present |
RBS-2417 |
|||||||
|
– Number of Transport blocks |
Reference to clause 6.10 Parameter Set |
RBS-2418 |
|||||||
|
– CHOICE Logical channel list |
All |
RBS-2419 |
|||||||
|
– Semi-static Transport Format information |
RBS-2420 |
||||||||
|
– Transmission time interval |
Reference to clause 6.10 Parameter Set |
RBS-2421 |
|||||||
|
– Type of channel coding |
Reference to clause 6.10 Parameter Set |
RBS-2422 |
|||||||
|
– Coding Rate |
Reference to clause 6.10 Parameter Set |
RBS-2423 |
|||||||
|
– Rate matching attribute |
Reference to clause 6.10 Parameter Set |
RBS-2424 |
|||||||
|
– CRC size |
Reference to clause 6.10 Parameter Set |
RBS-2425 |
|||||||
|
– Uplink transport channel type |
DCH |
RBS-2426 |
|||||||
|
– UL Transport channel identity |
2 |
RBS-2427 |
|||||||
|
– TFS |
RBS-2428 |
||||||||
|
– CHOICE Transport channel type |
Dedicated transport channels |
RBS-2429 |
|||||||
|
– Dynamic Transport format information |
RBS-2430 |
||||||||
|
– RLC Size |
Reference to clause 6.10 Parameter Set |
RBS-2431 |
|||||||
|
– Number of TBs and TTI List |
(This IE is repeated for TFI number.) |
RBS-2432 |
|||||||
|
– Transmission Time Interval |
Not Present |
RBS-2433 |
|||||||
|
– Number of Transport blocks |
Reference to clause 6.10 Parameter Set |
RBS-2434 |
|||||||
|
– CHOICE Logical channel list |
All |
RBS-2435 |
|||||||
|
– Semi-static Transport Format information |
RBS-2436 |
||||||||
|
– Transmission time interval |
Reference to clause 6.10 Parameter Set |
RBS-2437 |
|||||||
|
– Type of channel coding |
Reference to clause 6.10 Parameter Set |
RBS-2438 |
|||||||
|
– Coding Rate |
Reference to clause 6.10 Parameter Set |
RBS-2439 |
|||||||
|
– Rate matching attribute |
Reference to clause 6.10 Parameter Set |
RBS-2440 |
|||||||
|
– CRC size |
Reference to clause 6.10 Parameter Set |
RBS-2441 |
|||||||
|
– Uplink transport channel type |
DCH |
RBS-2442 |
|||||||
|
– UL Transport channel identity |
3 |
RBS-2443 |
|||||||
|
– TFS |
|
RBS-2444 |
|||||||
|
– CHOICE Transport channel type |
Dedicated transport channels |
RBS-2445 |
|||||||
|
– Dynamic Transport format information |
|
RBS-2446 |
|||||||
|
– RLC Size |
Reference to clause 6.10 Parameter Set |
RBS-2447 |
|||||||
|
– Number of TBs and TTI List |
(This IE is repeated for TFI number.) |
RBS-2448 |
|||||||
|
– Transmission Time Interval |
Not Present |
RBS-2449 |
|||||||
|
– Number of Transport blocks |
Reference to clause 6.10 Parameter Set |
RBS-2450 |
|||||||
|
– CHOICE Logical channel list |
All |
RBS-2451 |
|||||||
|
– Semi-static Transport Format information |
|
RBS-2452 |
|||||||
|
– Transmission time interval |
Reference to clause 6.10 Parameter Set |
RBS-2453 |
|||||||
|
– Type of channel coding |
Reference to clause 6.10 Parameter Set |
RBS-2454 |
|||||||
|
– Coding Rate |
Reference to clause 6.10 Parameter Set |
RBS-2455 |
|||||||
|
– Rate matching attribute |
Reference to clause 6.10 Parameter Set |
RBS-2456 |
|||||||
|
– CRC size |
Reference to clause 6.10 Parameter Set |
RBS-2457 |
|||||||
|
Added or Reconfigured UL TrCH information |
A12 |
1 E-DCH added, 1 DCH added, 1 DCH reconfigured |
Rel-6 |
RBS-2458 |
|||||
|
A19 |
Rel-7 |
RBS-2459 |
|||||||
|
– Uplink transport channel type |
E-DCH |
RBS-2460 |
|||||||
|
– CHOICE UL parameters |
E-DCH |
RBS-2461 |
|||||||
|
– UL MAC header type |
Not present |
Rel-8 |
RBS-2462 |
||||||
|
– UL MAC header type |
MAC-I-FIXED, MAC-I-FLEX |
MAC-i/is |
Rel-8 |
RBS-2463 |
|||||
|
– E-DCH Transmission Time Interval |
set to 2ms if supported by the UE E-DCH category, or 10ms if the UE E-DCH category does not support 2ms TTI |
RBS-2464 |
|||||||
|
– HARQ info for E-DCH |
RBS-2465 |
||||||||
|
– HARQ RV Configuration |
rvtable |
RBS-2466 |
|||||||
|
– Added or reconfigured E-DCH MAC-d flow |
RBS-2467 |
||||||||
|
– E-DCH MAC-d flow identity |
2 |
RBS-2468 |
|||||||
|
– E-DCH MAC-d flow power offset |
0 |
RBS-2469 |
|||||||
|
– E-DCH MAC-d flow maximum number of retransmissions |
7 |
RBS-2470 |
|||||||
|
– E-DCH MAC-d flow multiplexing list |
Not Present |
RBS-2471 |
|||||||
|
– CHOICE transmission grant type |
Scheduled grant info |
RBS-2472 |
|||||||
|
– Uplink transport channel type |
DCH |
RBS-2473 |
|||||||
|
– UL Transport channel identity |
1 |
RBS-2474 |
|||||||
|
– TFS |
RBS-2475 |
||||||||
|
– CHOICE Transport channel type |
Dedicated transport channels |
RBS-2476 |
|||||||
|
– Dynamic Transport format information |
RBS-2477 |
||||||||
|
– RLC Size |
Reference to clause 6.10 Parameter Set |
RBS-2478 |
|||||||
|
– Number of TBs and TTI List |
(This IE is repeated for TFI number.) |
RBS-2479 |
|||||||
|
– Transmission Time Interval |
Not Present |
RBS-2480 |
|||||||
|
– Number of Transport blocks |
Reference to clause 6.10 Parameter Set |
RBS-2481 |
|||||||
|
– CHOICE Logical channel list |
All |
RBS-2482 |
|||||||
|
– Semi-static Transport Format information |
RBS-2483 |
||||||||
|
– Transmission time interval |
Reference to clause 6.10 Parameter Set |
RBS-2484 |
|||||||
|
– Type of channel coding |
Reference to clause 6.10 Parameter Set |
RBS-2485 |
|||||||
|
– Coding Rate |
Reference to clause 6.10 Parameter Set |
RBS-2486 |
|||||||
|
– Rate matching attribute |
Reference to clause 6.10 Parameter Set |
RBS-2487 |
|||||||
|
– CRC size |
Reference to clause 6.10 Parameter Set |
RBS-2488 |
|||||||
|
– Uplink transport channel type |
DCH |
RBS-2489 |
|||||||
|
– UL Transport channel identity |
5 |
RBS-2490 |
|||||||
|
– TFS |
RBS-2491 |
||||||||
|
– CHOICE Transport channel type |
Dedicated transport channels |
RBS-2492 |
|||||||
|
– Dynamic Transport format information |
RBS-2493 |
||||||||
|
– RLC Size |
Reference to clause 6.10 Parameter Set |
RBS-2494 |
|||||||
|
– Number of TBs and TTI List |
(This IE is repeated for TFI number.) |
RBS-2495 |
|||||||
|
– Transmission Time Interval |
Not Present |
RBS-2496 |
|||||||
|
– Number of Transport blocks |
Reference to clause 6.10 Parameter Set |
RBS-2497 |
|||||||
|
– CHOICE Logical channel list |
All |
RBS-2498 |
|||||||
|
– Semi-static Transport Format information |
RBS-2499 |
||||||||
|
– Transmission time interval |
Reference to clause 6.10 Parameter Set |
RBS-2500 |
|||||||
|
– Type of channel coding |
Reference to clause 6.10 Parameter Set |
RBS-2501 |
|||||||
|
– Coding Rate |
Reference to clause 6.10 Parameter Set |
RBS-2502 |
|||||||
|
– Rate matching attribute |
Reference to clause 6.10 Parameter Set |
RBS-2503 |
|||||||
|
– CRC size |
Reference to clause 6.10 Parameter Set |
RBS-2504 |
|||||||
|
Added or Reconfigured UL TrCH information |
A13, A14 |
1 E-DCH added with one DCCH MAC-d flow and one DTCH MAC-d flow |
Rel-6 |
RBS-2505 |
|||||
|
, A17b, A17c, A17d, A17e, A19a, A20, A28a |
Rel-7 |
RBS-2506 |
|||||||
|
, A25, A25b, A27, A27a |
Rel-8 |
RBS-2507 |
|||||||
|
, A25c, A31, A32 , A33, A34, A36, A37 |
Rel-9 Rel-10 |
RBS-2508 |
|||||||
|
– Uplink transport channel type |
E-DCH |
RBS-2509 |
|||||||
|
– CHOICE UL parameters |
E-DCH |
RBS-2510 |
|||||||
|
– UL MAC header type |
Not present |
Rel-8 |
RBS-2511 |
||||||
|
– UL MAC header type |
MAC-I-FIXED, MAC-I-FLEX |
MAC-i/is |
Rel-8 |
RBS-2512 |
|||||
|
– E-DCH Transmission Time Interval |
set to 2ms if supported by the UE E-DCH category, or 10ms if the UE E-DCH category does not support 2ms TTI |
RBS-2513 |
|||||||
|
– HARQ info for E-DCH |
RBS-2514 |
||||||||
|
– HARQ RV Configuration |
rvtable |
RBS-2515 |
|||||||
|
– Added or reconfigured E-DCH MAC-d flow |
(for DCCH) |
RBS-2516 |
|||||||
|
– E-DCH MAC-d flow identity |
1 |
RBS-2517 |
|||||||
|
– E-DCH MAC-d flow power offset |
0 |
RBS-2518 |
|||||||
|
– E-DCH MAC-d flow maximum number of retransmissions |
7 |
RBS-2519 |
|||||||
|
– E-DCH MAC-d flow multiplexing list |
Not Present |
RBS-2520 |
|||||||
|
– CHOICE transmission grant type |
Non-scheduled grant info |
RBS-2521 |
|||||||
|
– Max MAC-e PDU contents size |
MAC-I-FIXED, MAC-I-FLEX |
168 bits |
Rel-8 |
RBS-2522 |
|||||
|
– Max MAC-e PDU contents size |
162 bits |
RBS-2523 |
|||||||
|
– 2 ms non-scheduled transmission grant HARQ process allocation |
Not Present |
RBS-2524 |
|||||||
|
– Added or reconfigured E-DCH MAC-d flow |
(for DTCH) |
RBS-2525 |
|||||||
|
– E-DCH MAC-d flow identity |
2 |
RBS-2526 |
|||||||
|
– E-DCH MAC-d flow power offset |
0 |
RBS-2527 |
|||||||
|
– E-DCH MAC-d flow maximum number of retransmissions |
7 |
RBS-2528 |
|||||||
|
– E-DCH MAC-d flow multiplexing list |
Not Present |
RBS-2529 |
|||||||
|
– CHOICE transmission grant type |
Scheduled grant info |
RBS-2530 |
|||||||
|
Added or Reconfigured UL TrCH information |
A15 |
1 E-DCH added with one DCCH MAC-d flow and two DTCH MAC-d flows |
Rel-6 |
RBS-2531 |
|||||
|
– Uplink transport channel type |
E-DCH |
RBS-2532 |
|||||||
|
– CHOICE UL parameters |
E-DCH |
RBS-2533 |
|||||||
|
– UL MAC header type |
Not present |
Rel-8 |
RBS-2534 |
||||||
|
– UL MAC header type |
MAC-I-FIXED, MAC-I-FLEX |
MAC-i/is |
Rel-8 |
RBS-2535 |
|||||
|
– E-DCH Transmission Time Interval |
set to 2ms if supported by the UE E-DCH category, or 10ms if the UE E-DCH category does not support 2ms TTI |
RBS-2536 |
|||||||
|
– HARQ info for E-DCH |
RBS-2537 |
||||||||
|
– HARQ RV Configuration |
rvtable |
RBS-2538 |
|||||||
|
– Added or reconfigured E-DCH MAC-d flow |
(for DCCH) |
RBS-2539 |
|||||||
|
– E-DCH MAC-d flow identity |
1 |
RBS-2540 |
|||||||
|
– E-DCH MAC-d flow power offset |
0 |
RBS-2541 |
|||||||
|
– E-DCH MAC-d flow maximum number of retransmissions |
7 |
RBS-2542 |
|||||||
|
– E-DCH MAC-d flow multiplexing list |
Not Present |
RBS-2543 |
|||||||
|
– CHOICE transmission grant type |
Non-scheduled grant info |
RBS-2544 |
|||||||
|
– Max MAC-e PDU contents size |
162 bits |
RBS-2545 |
|||||||
|
– Max MAC-e PDU contents size |
MAC-I-FIXED, MAC-I-FLEX |
168 bits |
Rel-8 |
RBS-2546 |
|||||
|
– 2 ms non-scheduled transmission grant HARQ process allocation |
Not Present |
RBS-2547 |
|||||||
|
– Added or reconfigured E-DCH MAC-d flow |
(for first DTCH) |
RBS-2548 |
|||||||
|
– E-DCH MAC-d flow identity |
2 |
RBS-2549 |
|||||||
|
– E-DCH MAC-d flow power offset |
0 |
RBS-2550 |
|||||||
|
– E-DCH MAC-d flow maximum number of retransmissions |
7 |
RBS-2551 |
|||||||
|
– E-DCH MAC-d flow multiplexing list |
Not Present |
RBS-2552 |
|||||||
|
– CHOICE transmission grant type |
Scheduled grant info |
RBS-2553 |
|||||||
|
– Added or reconfigured E-DCH MAC-d flow |
(for second DTCH) |
RBS-2554 |
|||||||
|
– E-DCH MAC-d flow identity |
3 |
RBS-2555 |
|||||||
|
– E-DCH MAC-d flow power offset |
0 |
RBS-2556 |
|||||||
|
– E-DCH MAC-d flow maximum number of retransmissions |
7 |
RBS-2557 |
|||||||
|
– E-DCH MAC-d flow multiplexing list |
Not Present |
RBS-2558 |
|||||||
|
– CHOICE transmission grant type |
Scheduled grant info |
RBS-2559 |
|||||||
|
Added or Reconfigured UL TrCH information |
A16 |
1 E-DCH added with one DCCH MAC-d flow and two DTCH MAC-d flows |
Rel-6 |
RBS-2560 |
|||||
|
, A19b, A21, A22 |
Rel-7 |
RBS-2561 |
|||||||
|
– Uplink transport channel type |
E-DCH |
RBS-2562 |
|||||||
|
– CHOICE UL parameters |
E-DCH |
RBS-2563 |
|||||||
|
– UL MAC header type |
Not present |
Rel-8 |
RBS-2564 |
||||||
|
– UL MAC header type |
MAC-I-FIXED, MAC-I-FLEX |
MAC-i/is |
Rel-8 |
RBS-2565 |
|||||
|
– CHOICE mode |
FDD |
Rel-7 |
RBS-2566 |
||||||
|
– E-DCH Transmission Time Interval |
set to 2ms if supported by the UE E-DCH category, or 10ms if the UE E-DCH category does not support 2ms TTI |
RBS-2567 |
|||||||
|
– HARQ info for E-DCH |
RBS-2568 |
||||||||
|
– HARQ RV Configuration |
rvtable |
RBS-2569 |
|||||||
|
– Added or reconfigured E-DCH MAC-d flow |
(for DCCH) |
RBS-2570 |
|||||||
|
– E-DCH MAC-d flow identity |
1 |
RBS-2571 |
|||||||
|
– E-DCH MAC-d flow power offset |
0 |
RBS-2572 |
|||||||
|
– E-DCH MAC-d flow maximum number of retransmissions |
7 |
RBS-2573 |
|||||||
|
– E-DCH MAC-d flow multiplexing list |
Not Present |
RBS-2574 |
|||||||
|
– CHOICE transmission grant type |
Non-scheduled grant info |
RBS-2575 |
|||||||
|
– Max MAC-e PDU contents size |
162 bits |
RBS-2576 |
|||||||
|
– Max MAC-e PDU contents size |
MAC-I-FIXED, MAC-I-FLEX |
168 bits |
Rel-8 |
RBS-2577 |
|||||
|
– 2 ms non-scheduled transmission grant HARQ process allocation |
Not Present |
RBS-2578 |
|||||||
|
– Added or reconfigured E-DCH MAC-d flow |
(for first DTCH) |
RBS-2579 |
|||||||
|
– E-DCH MAC-d flow identity |
2 |
RBS-2580 |
|||||||
|
– E-DCH MAC-d flow power offset |
0 |
RBS-2581 |
|||||||
|
– E-DCH MAC-d flow maximum number of retransmissions |
7 |
RBS-2582 |
|||||||
|
– E-DCH MAC-d flow multiplexing list |
Not Present |
RBS-2583 |
|||||||
|
– CHOICE transmission grant type |
Scheduled grant info |
RBS-2584 |
|||||||
|
– Added or reconfigured E-DCH MAC-d flow |
(for second DTCH) |
RBS-2585 |
|||||||
|
– E-DCH MAC-d flow identity |
4 |
RBS-2586 |
|||||||
|
– E-DCH MAC-d flow power offset |
0 |
RBS-2587 |
|||||||
|
– E-DCH MAC-d flow maximum number of retransmissions |
7 |
RBS-2588 |
|||||||
|
– E-DCH MAC-d flow multiplexing list |
Not Present |
RBS-2589 |
|||||||
|
– CHOICE transmission grant type |
Scheduled grant info |
RBS-2590 |
|||||||
|
Added or Reconfigured UL TrCH information |
A23 |
1 E-DCH added with one DCCH MAC-d flow and one DTCH MAC-d flow |
Rel-7 Rel-8 |
RBS-2591 |
|||||
|
– Uplink transport channel type |
E-DCH |
RBS-2592 |
|||||||
|
– CHOICE UL parameters |
E-DCH |
RBS-2593 |
|||||||
|
– UL MAC header type |
Not present |
Rel-8 |
RBS-2594 |
||||||
|
– UL MAC header type |
MAC-I-FIXED, MAC-I-FLEX |
MAC-i/is |
Rel-8 |
RBS-2595 |
|||||
|
– E-DCH Transmission Time Interval |
set to 2ms if supported by the UE E-DCH category, or 10ms if the UE E-DCH category does not support 2ms TTI |
RBS-2596 |
|||||||
|
– HARQ info for E-DCH |
RBS-2597 |
||||||||
|
– HARQ RV Configuration |
rvtable |
RBS-2598 |
|||||||
|
– Added or reconfigured E-DCH MAC-d flow |
(for DCCH) |
RBS-2599 |
|||||||
|
– E-DCH MAC-d flow identity |
1 |
RBS-2600 |
|||||||
|
– E-DCH MAC-d flow power offset |
0 |
RBS-2601 |
|||||||
|
– E-DCH MAC-d flow maximum number of retransmissions |
7 |
RBS-2602 |
|||||||
|
– E-DCH MAC-d flow multiplexing list |
Not Present |
RBS-2603 |
|||||||
|
– CHOICE transmission grant type |
Non-scheduled grant info |
RBS-2604 |
|||||||
|
– Max MAC-e PDU contents size |
162 bits |
Rel-6 |
RBS-2605 |
||||||
|
– Max MAC-e PDU contents size |
MAC-I-FIXED, MAC-I-FLEX |
168 bits |
Rel-8 |
RBS-2606 |
|||||
|
– 2 ms non-scheduled transmission grant HARQ process allocation |
‘01000000’B if 2ms TTI configured otherwise Not Present |
RBS-2607 |
|||||||
|
– Added or reconfigured E-DCH MAC-d flow |
(for DTCH) |
RBS-2608 |
|||||||
|
– E-DCH MAC-d flow identity |
2 |
RBS-2609 |
|||||||
|
– E-DCH MAC-d flow power offset |
0 |
RBS-2610 |
|||||||
|
– E-DCH MAC-d flow maximum number of retransmissions |
3 if 2ms TTI configured, otherwise 1 |
RBS-2611 |
|||||||
|
– E-DCH MAC-d flow multiplexing list |
Not Present |
RBS-2612 |
|||||||
|
– CHOICE transmission grant type |
Non-scheduled grant info |
RBS-2613 |
|||||||
|
– Max MAC-e PDU contents size |
546 bits |
Rel-6 |
RBS-2614 |
||||||
|
– Max MAC-e PDU contents size |
MAC-I-FIXED, MAC-I-FLEX |
552 bits |
Rel-8 |
RBS-2615 |
|||||
|
Added or Reconfigured UL TrCH information |
A26 |
1 E-DCH added with one DCCH MAC-d flow and three DTCH MAC-d flows |
Rel-8 |
RBS-2616 |
|||||
|
– Uplink transport channel type |
E-DCH |
RBS-2617 |
|||||||
|
– CHOICE UL parameters |
E-DCH |
RBS-2618 |
|||||||
|
– UL MAC header type |
Not present |
RBS-2619 |
|||||||
|
– UL MAC header type |
MAC-i/is |
RBS-2620 |
|||||||
|
– CHOICE mode |
FDD |
Rel-7 |
RBS-2621 |
||||||
|
– E-DCH Transmission Time Interval |
set to 2ms if supported by the UE E-DCH category, or 10ms if the UE E-DCH category does not support 2ms TTI |
RBS-2622 |
|||||||
|
– HARQ info for E-DCH |
RBS-2623 |
||||||||
|
– HARQ RV Configuration |
rvtable |
RBS-2624 |
|||||||
|
– Added or reconfigured E-DCH MAC-d flow |
(for DCCH) |
RBS-2625 |
|||||||
|
– E-DCH MAC-d flow identity |
1 |
RBS-2626 |
|||||||
|
– E-DCH MAC-d flow power offset |
0 |
RBS-2627 |
|||||||
|
– E-DCH MAC-d flow maximum number of retransmissions |
7 |
RBS-2628 |
|||||||
|
– E-DCH MAC-d flow multiplexing list |
Not Present |
RBS-2629 |
|||||||
|
– CHOICE transmission grant type |
Non-scheduled grant info |
RBS-2630 |
|||||||
|
– Max MAC-e PDU contents size |
168 bits |
RBS-2631 |
|||||||
|
– 2 ms non-scheduled transmission grant HARQ process allocation |
Not Present |
RBS-2632 |
|||||||
|
– Added or reconfigured E-DCH MAC-d flow |
(for first DTCH) |
RBS-2633 |
|||||||
|
– E-DCH MAC-d flow identity |
2 |
RBS-2634 |
|||||||
|
– E-DCH MAC-d flow power offset |
0 |
RBS-2635 |
|||||||
|
– E-DCH MAC-d flow maximum number of retransmissions |
7 |
RBS-2636 |
|||||||
|
– E-DCH MAC-d flow multiplexing list |
Not Present |
RBS-2637 |
|||||||
|
– CHOICE transmission grant type |
Scheduled grant info |
RBS-2638 |
|||||||
|
– Added or reconfigured E-DCH MAC-d flow |
(for second DTCH) |
RBS-2639 |
|||||||
|
– E-DCH MAC-d flow identity |
3 |
RBS-2640 |
|||||||
|
– E-DCH MAC-d flow power offset |
0 |
RBS-2641 |
|||||||
|
– E-DCH MAC-d flow maximum number of retransmissions |
7 |
RBS-2642 |
|||||||
|
– E-DCH MAC-d flow multiplexing list |
Not Present |
RBS-2643 |
|||||||
|
– CHOICE transmission grant type |
Scheduled grant info |
RBS-2644 |
|||||||
|
– Added or reconfigured E-DCH MAC-d flow |
(for third DTCH) |
RBS-2645 |
|||||||
|
– E-DCH MAC-d flow identity |
4 |
RBS-2646 |
|||||||
|
– E-DCH MAC-d flow power offset |
0 |
RBS-2647 |
|||||||
|
– E-DCH MAC-d flow maximum number of retransmissions |
7 |
RBS-2648 |
|||||||
|
– E-DCH MAC-d flow multiplexing list |
Not Present |
RBS-2649 |
|||||||
|
– CHOICE transmission grant type |
Scheduled grant info |
RBS-2650 |
|||||||
|
Added or Reconfigured UL TrCH information |
A29 |
1 E-DCH added with one DTCH MAC-d flow |
Rel-8 |
RBS-2651 |
|||||
|
– Uplink transport channel type |
E-DCH |
RBS-2652 |
|||||||
|
– CHOICE UL parameters |
E-DCH |
RBS-2653 |
|||||||
|
– UL MAC header type |
MAC-I-FIXED, MAC-I-FLEX |
MAC-i/is |
Rel-8 |
RBS-2654 |
|||||
|
– E-DCH Transmission Time Interval |
set to 2ms if supported by the UE E-DCH category, or 10ms if the UE E-DCH category does not support 2ms TTI |
RBS-2655 |
|||||||
|
– HARQ info for E-DCH |
RBS-2656 |
||||||||
|
– HARQ RV Configuration |
rvtable |
RBS-2657 |
|||||||
|
– Added or reconfigured E-DCH MAC-d flow |
RBS-2658 |
||||||||
|
– E-DCH MAC-d flow identity |
0 |
RBS-2659 |
|||||||
|
– E-DCH MAC-d flow power offset |
0 |
RBS-2660 |
|||||||
|
– E-DCH MAC-d flow maximum number of retransmissions |
7 |
RBS-2661 |
|||||||
|
– E-DCH MAC-d flow multiplexing list |
Not Present |
RBS-2662 |
|||||||
|
– CHOICE transmission grant type |
Scheduled grant info |
RBS-2663 |
|||||||
|
Added or Reconfigured UL TrCH information |
A30 |
1 E-DCH added with one DCCH MAC-d flow and one DTCH MAC-d flow |
Rel-8 |
RBS-2664 |
|||||
|
– Uplink transport channel type |
E-DCH |
RBS-2665 |
|||||||
|
– CHOICE UL parameters |
E-DCH |
RBS-2666 |
|||||||
|
– UL MAC header type |
MAC-I-FIXED, MAC-I-FLEX |
MAC-i/is |
RBS-2667 |
||||||
|
– E-DCH Transmission Time Interval |
set to 2ms if supported by the UE E-DCH category, or 10ms if the UE E-DCH category does not support 2ms TTI |
RBS-2668 |
|||||||
|
– HARQ info for E-DCH |
RBS-2669 |
||||||||
|
– HARQ RV Configuration |
rvtable |
RBS-2670 |
|||||||
|
– Added or reconfigured E-DCH MAC-d flow |
(for DCCH) |
RBS-2671 |
|||||||
|
– E-DCH MAC-d flow identity |
3 |
RBS-2672 |
|||||||
|
– E-DCH MAC-d flow power offset |
0 |
RBS-2673 |
|||||||
|
– E-DCH MAC-d flow maximum number of retransmissions |
7 |
RBS-2674 |
|||||||
|
– E-DCH MAC-d flow multiplexing list |
Not Present |
RBS-2675 |
|||||||
|
– CHOICE transmission grant type |
Non-scheduled grant info |
RBS-2676 |
|||||||
|
– Max MAC-e PDU contents size |
168 bits |
RBS-2677 |
|||||||
|
– 2 ms non-scheduled transmission grant HARQ process allocation |
Not Present |
RBS-2678 |
|||||||
|
– Added or reconfigured E-DCH MAC-d flow |
(for DTCH) |
RBS-2679 |
|||||||
|
– E-DCH MAC-d flow identity |
2 |
RBS-2680 |
|||||||
|
– E-DCH MAC-d flow power offset |
0 |
RBS-2681 |
|||||||
|
– E-DCH MAC-d flow maximum number of retransmissions |
7 |
RBS-2682 |
|||||||
|
– E-DCH MAC-d flow multiplexing list |
Not Present |
RBS-2683 |
|||||||
|
– CHOICE transmission grant type |
Scheduled grant info |
RBS-2684 |
|||||||
|
Added or Reconfigured UL TrCH information |
A17f, A35 A38, A39, A40, A41, A42, A43, A44, A45 |
1 E-DCH added, 1 DCH reconfigured |
Rel-7 Rel-10 Rel-11 |
RBS-2685 |
|||||
|
– Uplink transport channel type |
E-DCH |
RBS-2686 |
|||||||
|
– CHOICE UL parameters |
E-DCH |
RBS-2687 |
|||||||
|
– UL MAC header type |
MAC-I-FIXED, MAC-I-FLEX |
MAC-i/is |
Rel-8 |
RBS-2688 |
|||||
|
– E-DCH Transmission Time Interval |
set to 2ms if supported by the UE E-DCH category, or 10ms if the UE E-DCH category does not support 2ms TTI |
RBS-2689 |
|||||||
|
– HARQ info for E-DCH |
RBS-2690 |
||||||||
|
– HARQ RV Configuration |
rvtable |
RBS-2691 |
|||||||
|
– Added or reconfigured E-DCH MAC-d flow |
RBS-2692 |
||||||||
|
– E-DCH MAC-d flow identity |
2 |
RBS-2693 |
|||||||
|
– E-DCH MAC-d flow power offset |
0 |
RBS-2694 |
|||||||
|
– E-DCH MAC-d flow maximum number of retransmissions |
7 |
RBS-2695 |
|||||||
|
– E-DCH MAC-d flow multiplexing list |
Not Present |
RBS-2696 |
|||||||
|
– CHOICE transmission grant type |
Scheduled grant info |
RBS-2697 |
|||||||
|
– Uplink transport channel type |
DCH |
RBS-2698 |
|||||||
|
– UL Transport channel identity |
5 |
RBS-2699 |
|||||||
|
– TFS |
RBS-2700 |
||||||||
|
– CHOICE Transport channel type |
Dedicated transport channels |
RBS-2701 |
|||||||
|
– Dynamic Transport format information |
RBS-2702 |
||||||||
|
– RLC Size |
Reference to clause 6.10 Parameter Set |
RBS-2703 |
|||||||
|
– Number of TBs and TTI List |
(This IE is repeated for TFI number.) |
RBS-2704 |
|||||||
|
– Transmission Time Interval |
Not Present |
RBS-2705 |
|||||||
|
– Number of Transport blocks |
Reference to clause 6.10 Parameter Set |
RBS-2706 |
|||||||
|
– CHOICE Logical channel list |
All |
RBS-2707 |
|||||||
|
– Semi-static Transport Format information |
RBS-2708 |
||||||||
|
– Transmission time interval |
Reference to clause 6.10 Parameter Set |
RBS-2709 |
|||||||
|
– Type of channel coding |
Reference to clause 6.10 Parameter Set |
RBS-2710 |
|||||||
|
– Coding Rate |
Reference to clause 6.10 Parameter Set |
RBS-2711 |
|||||||
|
– Rate matching attribute |
Reference to clause 6.10 Parameter Set |
RBS-2712 |
|||||||
|
– CRC size |
Reference to clause 6.10 Parameter Set |
RBS-2713 |
|||||||
|
DL Transport channel information common for all transport channel |
A1, A2, A7, A8 |
RBS-2714 |
|||||||
|
– SCCPCH TFCS |
Not Present |
RBS-2715 |
|||||||
|
– CHOICE mode |
FDD |
RBS-2716 |
|||||||
|
– CHOICE DL parameters |
SameasUL |
RBS-2717 |
|||||||
|
DL Transport channel information common for all transport channel |
A3, A4, A5, A6, A11 |
RBS-2718 |
|||||||
|
A10 |
Rel-5 |
RBS-2719 |
|||||||
|
, A12, A13, A15 |
Rel-6 |
RBS-2720 |
|||||||
|
, A17, A18, A17a, A17d, A17e, A17f, A19, A19a, |
Rel-7 |
RBS-2721 |
|||||||
|
, A25a, A25b, A26, A28 |
Rel-8 |
RBS-2722 |
|||||||
|
, A31, A32 , A33, A34, A35, A36, A37 A38, A39, A40, A41, A42, A43, A44, A45 |
Rel-9 Rel-10 Rel-11 |
RBS-2723 |
|||||||
|
– SCCPCH TFCS |
Not Present |
RBS-2724 |
|||||||
|
– CHOICE mode |
FDD |
RBS-2725 |
|||||||
|
– CHOICE DL parameters |
Explicit |
RBS-2726 |
|||||||
|
– DL DCH TFCS |
|
RBS-2727 |
|||||||
|
– CHOICE TFCI Signalling |
Normal |
RBS-2728 |
|||||||
|
– TFCI Field 1 Information |
|
RBS-2729 |
|||||||
|
– CHOICE TFCS representation |
Complete reconfiguration |
RBS-2730 |
|||||||
|
– TFCS complete reconfigure |
|
RBS-2731 |
|||||||
|
– CHOICE CTFC Size |
Number of bits used must be enough to cover all combinations of CTFC from clause 6.10.2.4 Parameter Set. |
RBS-2732 |
|||||||
|
– CTFC information |
This IE is repeated for TFC numbers and reference to clause 6.10.2.4 |
RBS-2733 |
|||||||
|
– CTFC |
Reference to clause 6.10.2.4 Parameter Set |
RBS-2734 |
|||||||
|
– Power offset information |
Not Present |
RBS-2735 |
|||||||
|
DL Transport channel information common for all transport channel |
A9 |
Rel-5 |
RBS-2736 |
||||||
|
– SCCPCH TFCS |
Not Present |
RBS-2737 |
|||||||
|
– CHOICE mode |
FDD |
RBS-2738 |
|||||||
|
– CHOICE DL parameters |
Explicit |
RBS-2739 |
|||||||
|
– DL DCH TFCS |
|
RBS-2740 |
|||||||
|
– CHOICE TFCI Signalling |
Normal |
RBS-2741 |
|||||||
|
– TFCI Field 1 Information |
|
RBS-2742 |
|||||||
|
– CHOICE TFCS representation |
Complete reconfiguration |
RBS-2743 |
|||||||
|
– TFCS complete reconfigure |
|
RBS-2744 |
|||||||
|
– CHOICE CTFC Size |
ctfc2bit |
RBS-2745 |
|||||||
|
– CTFC information |
|
RBS-2746 |
|||||||
|
– CTFC |
0 ((DL DCH RAB, DCCH)=(TF0, TF0)) |
RBS-2747 |
|||||||
|
– Power offset information |
Not Present |
RBS-2748 |
|||||||
|
– CTFC |
1 ((DL DCH RAB, DCCH)=(TF0, TF1)) |
RBS-2749 |
|||||||
|
– Power offset information |
Not Present |
RBS-2750 |
|||||||
|
DL Transport channel information common for all transport channel |
A14, A16 |
Not Present |
Rel-6 |
RBS-2751 |
|||||
|
, A17b, A17c, A19b, A20, A21, A22, A24 |
Rel-7 |
RBS-2752 |
|||||||
|
, A23, A28a |
Rel-7 Rel-8 |
RBS-2753 |
|||||||
|
, A25, A27, A27a, A29, A30, A25c |
Rel-8 Rel-9 |
RBS-2754 |
|||||||
|
Deleted DL TrCH information |
A1, A2, A3, A4, A5, A6, A7, A8 |
Not Present |
RBS-2755 |
||||||
|
, A9, A10 |
Rel-5 |
RBS-2756 |
|||||||
|
, A12, A13 |
Rel-6 |
RBS-2757 |
|||||||
|
, A17, A18, A17a, A17d, A17e, A17f, A19, A19a, A20, A21, A24 |
Rel-7 |
RBS-2758 |
|||||||
|
, A25a, A25b, A26, A28, A29 |
Rel-8 |
RBS-2759 |
|||||||
|
, A35 A38, A39, A40, A41, A42, A43, A44, A45 |
Rel-9 Rel-10 Rel-11 |
RBS-2760 |
|||||||
|
Deleted DL TrCH information |
A14, A16 |
Rel-6 |
RBS-2761 |
||||||
|
A17b, A17c, A19b, A22 |
Rel-7 |
RBS-2762 |
|||||||
|
A25, A27, A27a, A25c, A28a |
RBS-2763 |
||||||||
|
, A31, A32 |
Rel-9 |
RBS-2764 |
|||||||
|
, A33, A34, A36, A37 |
Rel-10 |
RBS-2765 |
|||||||
|
– Downlink transport channel type |
DCH |
RBS-2766 |
|||||||
|
– DL Transport channel identity |
10 |
RBS-2767 |
|||||||
|
Deleted DL TrCH information – Downlink transport channel type – DL HS-DSCH MAC-d flow identity |
A30 |
mac_ehs 1 |
Rel-8 |
RBS-2767a |
|||||
|
Added or Reconfigured DL TrCH information |
A1 |
1 DCH added, 1 DCH reconfigured |
RBS-2768 |
||||||
|
– Downlink transport channel type |
DCH |
RBS-2769 |
|||||||
|
– DL Transport channel identity |
6 |
RBS-2770 |
|||||||
|
– CHOICE DL parameters |
Same as UL |
RBS-2771 |
|||||||
|
– Uplink transport channel type |
DCH |
RBS-2772 |
|||||||
|
– UL TrCH identity |
1 |
RBS-2773 |
|||||||
|
– DCH quality target |
RBS-2774 |
||||||||
|
– BLER Quality value |
-20 (-2.0) |
RBS-2775 |
|||||||
|
– Downlink transport channel type |
DCH |
RBS-2776 |
|||||||
|
– DL Transport channel identity |
10 |
RBS-2777 |
|||||||
|
– CHOICE DL parameters |
Same as UL |
RBS-2778 |
|||||||
|
– Uplink transport channel type |
DCH |
RBS-2779 |
|||||||
|
– UL TrCH identity |
5 |
RBS-2780 |
|||||||
|
– DCH quality target |
RBS-2781 |
||||||||
|
– BLER Quality value |
-20 (-2.0) |
RBS-2782 |
|||||||
|
Added or Reconfigured DL TrCH information |
A3, A4, A5, A6, A7 |
2 TrCHs(DCH for DCCH and DCH for DTCH) |
RBS-2783 |
||||||
|
– Downlink transport channel type |
DCH |
RBS-2784 |
|||||||
|
– DL Transport channel identity |
10 |
RBS-2785 |
|||||||
|
– CHOICE DL parameters |
Same as UL |
RBS-2786 |
|||||||
|
– Uplink transport channel type |
DCH |
RBS-2787 |
|||||||
|
– UL TrCH identity |
5 |
RBS-2788 |
|||||||
|
– DCH quality target |
RBS-2789 |
||||||||
|
– BLER Quality value |
-20 (-2.0) |
RBS-2790 |
|||||||
|
– Downlink transport channel type |
DCH |
RBS-2791 |
|||||||
|
– DL Transport channel identity |
6 |
RBS-2792 |
|||||||
|
– CHOICE DL parameters |
Explicit Except for RAB with the symmetric DL and UL rate: Same as UL |
RBS-2793 |
|||||||
|
– TFS |
RBS-2794 |
||||||||
|
– CHOICE Transport channel type |
Dedicated transport channel |
RBS-2795 |
|||||||
|
– Dynamic transport format information |
RBS-2796 |
||||||||
|
– RLC Size |
Reference to clause 6.10 Parameter Set |
RBS-2797 |
|||||||
|
– Number of TBs and TTI List |
(This IE is repeated for TFI number.) |
RBS-2798 |
|||||||
|
– Transmission Time Interval |
Not Present |
RBS-2799 |
|||||||
|
– Number of Transport blocks |
Reference to clause 6.10 Parameter Set only including TF0 |
RBS-2800 |
|||||||
|
– CHOICE Logical channel list |
All |
RBS-2801 |
|||||||
|
– Semi-static Transport Format information |
RBS-2802 |
||||||||
|
– Transmission time interval |
Reference to clause 6.10 Parameter Set |
RBS-2803 |
|||||||
|
– Type of channel coding |
Reference to clause 6.10 Parameter Set |
RBS-2804 |
|||||||
|
– Coding Rate |
Reference to clause 6.10 Parameter Set |
RBS-2805 |
|||||||
|
– Rate matching attribute |
Reference to clause 6.10 Parameter Set |
RBS-2806 |
|||||||
|
– CRC size |
Reference to clause 6.10 Parameter Set |
RBS-2807 |
|||||||
|
– DCH quality target |
RBS-2808 |
||||||||
|
– BLER Quality value |
-20 (-2.0) |
RBS-2809 |
|||||||
|
Added or Reconfigured DL TrCH information |
A2, A8 |
4 TrCHs(DCH for DCCH and 3DCHs for DTCH) |
RBS-2810 |
||||||
|
– Downlink transport channel type |
DCH |
RBS-2811 |
|||||||
|
– DL Transport channel identity |
10 |
RBS-2812 |
|||||||
|
– CHOICE DL parameters |
Same as UL |
RBS-2813 |
|||||||
|
– Uplink transport channel type |
DCH |
RBS-2814 |
|||||||
|
– UL TrCH identity |
5 |
RBS-2815 |
|||||||
|
– DCH quality target |
RBS-2816 |
||||||||
|
– BLER Quality value |
-20 (-2.0) |
RBS-2817 |
|||||||
|
– Downlink transport channel type |
DCH |
RBS-2818 |
|||||||
|
– DL Transport channel identity |
6 |
RBS-2819 |
|||||||
|
– CHOICE DL parameters |
Explicit |
RBS-2820 |
|||||||
|
– TFS |
RBS-2821 |
||||||||
|
– CHOICE Transport channel type |
Dedicated transport channel |
RBS-2822 |
|||||||
|
– Dynamic transport format information |
RBS-2823 |
||||||||
|
– RLC Size |
Reference to clause 6.10 Parameter Set |
RBS-2824 |
|||||||
|
– Number of TBs and TTI List |
(This IE is repeated for TFI number.) |
RBS-2825 |
|||||||
|
– Dynamic transport format information |
RBS-2826 |
||||||||
|
– Transmission Time Interval |
Not Present |
RBS-2827 |
|||||||
|
– Number of Transport blocks |
Reference to clause 6.10 Parameter Set |
RBS-2828 |
|||||||
|
– CHOICE Logical channel list |
All |
RBS-2829 |
|||||||
|
– Semi-static Transport Format information |
RBS-2830 |
||||||||
|
– Transmission time interval |
Reference to clause 6.10 Parameter Set |
RBS-2831 |
|||||||
|
– Type of channel coding |
Reference to clause 6.10 Parameter Set |
RBS-2832 |
|||||||
|
– Coding Rate |
Reference to clause 6.10 Parameter Set |
RBS-2833 |
|||||||
|
– Rate matching attribute |
Reference to clause 6.10 Parameter Set |
RBS-2834 |
|||||||
|
– CRC size |
Reference to clause 6.10 Parameter Set |
RBS-2835 |
|||||||
|
– DCH quality target |
RBS-2836 |
||||||||
|
– BLER Quality value |
Not Present |
RBS-2837 |
|||||||
|
– Downlink transport channel type |
DCH |
RBS-2838 |
|||||||
|
– DL Transport channel identity |
7 |
RBS-2839 |
|||||||
|
– CHOICE DL parameters |
Explicit |
RBS-2840 |
|||||||
|
– TFS |
RBS-2841 |
||||||||
|
– CHOICE Transport channel type |
Dedicated transport channel |
RBS-2842 |
|||||||
|
– Dynamic transport format information |
RBS-2843 |
||||||||
|
– RLC Size |
Reference to clause 6.10 Parameter Set |
RBS-2844 |
|||||||
|
– Number of TBs and TTI List |
(This IE is repeated for TFI number.) |
RBS-2845 |
|||||||
|
– Dynamic transport format information |
RBS-2846 |
||||||||
|
– Transmission Time Interval |
Not Present |
RBS-2847 |
|||||||
|
– Number of Transport blocks |
Reference to clause 6.10 Parameter Set |
RBS-2848 |
|||||||
|
– CHOICE Logical channel list |
All |
RBS-2849 |
|||||||
|
– Semi-static Transport Format information |
RBS-2850 |
||||||||
|
– Transmission time interval |
Reference to clause 6.10 Parameter Set |
RBS-2851 |
|||||||
|
– Type of channel coding |
Reference to clause 6.10 Parameter Set |
RBS-2852 |
|||||||
|
– Coding Rate |
Reference to clause 6.10 Parameter Set |
RBS-2853 |
|||||||
|
– Rate matching attribute |
Reference to clause 6.10 Parameter Set |
RBS-2854 |
|||||||
|
– CRC size |
Reference to clause 6.10 Parameter Set |
RBS-2855 |
|||||||
|
– DCH quality target |
RBS-2856 |
||||||||
|
– BLER Quality value |
Not Present |
RBS-2857 |
|||||||
|
– Downlink transport channel type |
DCH |
RBS-2858 |
|||||||
|
– DL Transport channel identity |
8 |
RBS-2859 |
|||||||
|
– CHOICE DL parameters |
Explicit |
RBS-2860 |
|||||||
|
– TFS |
RBS-2861 |
||||||||
|
– CHOICE Transport channel type |
Dedicated transport channel |
RBS-2862 |
|||||||
|
– Dynamic transport format information |
RBS-2863 |
||||||||
|
– RLC Size |
Reference to clause 6.10 Parameter Set |
RBS-2864 |
|||||||
|
– Number of TBs and TTI List |
(This IE is repeated for TFI number.) |
RBS-2865 |
|||||||
|
– Dynamic transport format information |
RBS-2866 |
||||||||
|
– Transmission Time Interval |
Not Present |
RBS-2867 |
|||||||
|
– Number of Transport blocks |
Reference to clause 6.10 Parameter Set |
RBS-2868 |
|||||||
|
– CHOICE Logical channel list |
All |
RBS-2869 |
|||||||
|
– Semi-static Transport Format information |
RBS-2870 |
||||||||
|
– Transmission time interval |
Reference to clause 6.10 Parameter Set |
RBS-2871 |
|||||||
|
– Type of channel coding |
Reference to clause 6.10 Parameter Set |
RBS-2872 |
|||||||
|
– Coding Rate |
Reference to clause 6.10 Parameter Set |
RBS-2873 |
|||||||
|
– Rate matching attribute |
Reference to clause 6.10 Parameter Set |
RBS-2874 |
|||||||
|
– CRC size |
Reference to clause 6.10 Parameter Set |
RBS-2875 |
|||||||
|
– DCH quality target |
RBS-2876 |
||||||||
|
– BLER Quality value |
Not Present |
RBS-2877 |
|||||||
|
Added or Reconfigured DL TrCH information |
A9 |
3 TrCHs (DCH for DCCH and DCH plus HS-DSCH for DTCH) |
Rel-5 |
RBS-2878 |
|||||
|
A12 |
Rel-6 |
RBS-2879 |
|||||||
|
A19 |
Rel-7 |
RBS-2880 |
|||||||
|
– Downlink transport channel type |
DCH |
RBS-2881 |
|||||||
|
– DL Transport channel identity |
10 |
RBS-2882 |
|||||||
|
– CHOICE DL parameters |
Same as UL |
RBS-2883 |
|||||||
|
– Uplink transport channel type |
DCH |
RBS-2884 |
|||||||
|
– UL TrCH identity |
5 |
RBS-2885 |
|||||||
|
– DCH quality target |
|
RBS-2886 |
|||||||
|
– BLER Quality value |
-20 (-2.0) |
RBS-2887 |
|||||||
|
– Downlink transport channel type |
DCH |
RBS-2888 |
|||||||
|
– DL Transport channel identity |
6 |
RBS-2889 |
|||||||
|
– CHOICE DL parameters |
Explicit |
RBS-2890 |
|||||||
|
– TFS |
|
RBS-2891 |
|||||||
|
– CHOICE Transport channel type |
Dedicated transport channel |
RBS-2892 |
|||||||
|
– Dynamic transport format information |
|
RBS-2893 |
|||||||
|
– RLC Size |
Reference to clause 6.10 Parameter Set |
RBS-2894 |
|||||||
|
– Number of TBs and TTI List |
(This IE is repeated for TFI number.) |
RBS-2895 |
|||||||
|
– Dynamic transport format information |
|
RBS-2896 |
|||||||
|
– Transmission Time Interval |
Not Present |
RBS-2897 |
|||||||
|
– Number of Transport blocks |
Reference to clause 6.10 Parameter Set |
RBS-2898 |
|||||||
|
– CHOICE Logical channel list |
All |
RBS-2899 |
|||||||
|
– Semi-static Transport Format information |
|
RBS-2900 |
|||||||
|
– Transmission time interval |
Reference to clause 6.10 Parameter Set |
RBS-2901 |
|||||||
|
– Type of channel coding |
Reference to clause 6.10 Parameter Set |
RBS-2902 |
|||||||
|
– Coding Rate |
Reference to clause 6.10 Parameter Set |
RBS-2903 |
|||||||
|
– Rate matching attribute |
Reference to clause 6.10 Parameter Set |
RBS-2904 |
|||||||
|
– CRC size |
Reference to clause 6.10 Parameter Set |
RBS-2905 |
|||||||
|
– DCH quality target |
|
RBS-2906 |
|||||||
|
– BLER Quality value |
-20 (-2.0) |
RBS-2907 |
|||||||
|
– Downlink transport channel type |
HS-DSCH |
RBS-2908 |
|||||||
|
– DL Transport channel identity |
Not Present |
RBS-2909 |
|||||||
|
– CHOICE DL parameters |
HS-DSCH |
RBS-2910 |
|||||||
|
– HARQ Info |
|
RBS-2911 |
|||||||
|
– Number of Processes |
Reference to clause 6.10.2.4.5 Parameter Set |
RBS-2912 |
|||||||
|
– CHOICE Memory Partitioning |
Implicit |
RBS-2913 |
|||||||
|
– Added or reconfigured MAC-d flow |
|
RBS-2914 |
|||||||
|
– MAC-hs queue to add or reconfigure list |
(one queue) |
RBS-2915 |
|||||||
|
– MAC-hs queue Id |
0 |
RBS-2916 |
|||||||
|
– MAC-d Flow Identity |
0 |
RBS-2917 |
|||||||
|
– T1 |
50 |
RBS-2918 |
|||||||
|
– MAC-hs window size |
16 |
RBS-2919 |
|||||||
|
– MAC-d PDU size Info |
|
RBS-2920 |
|||||||
|
– MAC-d PDU size |
336 |
RBS-2921 |
|||||||
|
– MAC-d PDU size index |
0 |
RBS-2922 |
|||||||
|
– MAC-hs queue to delete list |
Not present |
RBS-2923 |
|||||||
|
– DCH quality target |
Not present |
RBS-2924 |
|||||||
|
Added or Reconfigured DL TrCH information |
A10 |
2 TrCHs (DCH for DCCH and HS-DSCH for DTCH) |
Rel-5 |
RBS-2925 |
|||||
|
– Downlink transport channel type |
DCH |
RBS-2926 |
|||||||
|
– DL Transport channel identity |
10 |
RBS-2927 |
|||||||
|
– CHOICE DL parameters |
Same as UL |
RBS-2928 |
|||||||
|
– Uplink transport channel type |
DCH |
RBS-2929 |
|||||||
|
– UL TrCH identity |
5 |
RBS-2930 |
|||||||
|
– DCH quality target |
|
RBS-2931 |
|||||||
|
– BLER Quality value |
-20 (-2.0) |
RBS-2932 |
|||||||
|
– Downlink transport channel type |
HS-DSCH |
RBS-2933 |
|||||||
|
– DL Transport channel identity |
Not Present |
RBS-2934 |
|||||||
|
– CHOICE DL parameters |
HS-DSCH |
RBS-2935 |
|||||||
|
– HARQ Info |
|
RBS-2936 |
|||||||
|
– Number of Processes |
Reference to clause 6.10.2.4.5 Parameter Set |
RBS-2937 |
|||||||
|
– CHOICE Memory Partitioning |
Implicit |
RBS-2938 |
|||||||
|
– Added or reconfigured MAC-d flow |
|
RBS-2939 |
|||||||
|
– MAC-hs queue to add or reconfigure list |
(one queue) |
RBS-2940 |
|||||||
|
– MAC-hs queue Id |
0 |
RBS-2941 |
|||||||
|
– MAC-d Flow Identity |
0 |
RBS-2942 |
|||||||
|
– T1 |
50 |
RBS-2943 |
|||||||
|
– MAC-hs window size |
16 |
RBS-2944 |
|||||||
|
– MAC-d PDU size Info |
|
RBS-2945 |
|||||||
|
– MAC-d PDU size |
336 |
RBS-2946 |
|||||||
|
– MAC-d PDU size index |
0 |
RBS-2947 |
|||||||
|
– MAC-hs queue to delete list |
Not present |
RBS-2948 |
|||||||
|
– DCH quality target |
Not present |
RBS-2949 |
|||||||
|
Added or Reconfigured DL TrCH information |
A11 |
1 DCH for DTCH |
RBS-2950 |
||||||
|
– Downlink transport channel type |
DCH |
RBS-2951 |
|||||||
|
– DL Transport channel identity |
9 |
RBS-2952 |
|||||||
|
– CHOICE DL parameters |
Explicit |
RBS-2953 |
|||||||
|
– TFS |
|
RBS-2954 |
|||||||
|
– CHOICE Transport channel type |
Dedicated transport channel |
RBS-2955 |
|||||||
|
– Dynamic transport format information |
|
RBS-2956 |
|||||||
|
– RLC Size |
Reference to clause 6.10 Parameter Set |
RBS-2957 |
|||||||
|
– Number of TBs and TTI List |
(This IE is repeated for TFI number.) |
RBS-2958 |
|||||||
|
– Dynamic transport format information |
|
RBS-2959 |
|||||||
|
– Transmission Time Interval |
Not Present |
RBS-2960 |
|||||||
|
– Number of Transport blocks |
Reference to clause 6.10 Parameter Set |
RBS-2961 |
|||||||
|
– CHOICE Logical channel list |
All |
RBS-2962 |
|||||||
|
– Semi-static Transport Format information |
|
RBS-2963 |
|||||||
|
– Transmission time interval |
Reference to clause 6.10 Parameter Set |
RBS-2964 |
|||||||
|
– Type of channel coding |
Reference to clause 6.10 Parameter Set |
RBS-2965 |
|||||||
|
– Coding Rate |
Reference to clause 6.10 Parameter Set |
RBS-2966 |
|||||||
|
– Rate matching attribute |
Reference to clause 6.10 Parameter Set |
RBS-2967 |
|||||||
|
– CRC size |
Reference to clause 6.10 Parameter Set |
RBS-2968 |
|||||||
|
– DCH quality target |
|
RBS-2969 |
|||||||
|
– BLER Quality value |
-20 (-2.0) |
RBS-2970 |
|||||||
|
Added or Reconfigured DL TrCH information |
A13 |
2 TrCHs (DCH for DCCH and HS-DSCH for DTCH) |
Rel-6 |
RBS-2971 |
|||||
|
– Downlink transport channel type |
DCH |
RBS-2972 |
|||||||
|
– DL Transport channel identity |
10 |
RBS-2973 |
|||||||
|
– CHOICE DL parameters |
Explicit |
RBS-2974 |
|||||||
|
– TFS |
RBS-2975 |
||||||||
|
– CHOICE Transport channel type |
Dedicated transport channels |
RBS-2976 |
|||||||
|
– Dynamic Transport format information |
RBS-2977 |
||||||||
|
– RLC Size |
Reference to clause 6.10 Parameter Set |
RBS-2978 |
|||||||
|
– Number of TBs and TTI List |
(This IE is repeated for TFI number.) |
RBS-2979 |
|||||||
|
– Transmission Time Interval |
Not Present |
RBS-2980 |
|||||||
|
– Number of Transport blocks |
Reference to clause 6.10 Parameter Set |
RBS-2981 |
|||||||
|
– CHOICE Logical channel list |
All |
RBS-2982 |
|||||||
|
– Semi-static Transport Format information |
RBS-2983 |
||||||||
|
– Transmission time interval |
Reference to clause 6.10 Parameter Set |
RBS-2984 |
|||||||
|
– Type of channel coding |
Reference to clause 6.10 Parameter Set |
RBS-2985 |
|||||||
|
– Coding Rate |
Reference to clause 6.10 Parameter Set |
RBS-2986 |
|||||||
|
– Rate matching attribute |
Reference to clause 6.10 Parameter Set |
RBS-2987 |
|||||||
|
– CRC size |
Reference to clause 6.10 Parameter Set |
RBS-2988 |
|||||||
|
– DCH quality target |
RBS-2989 |
||||||||
|
– BLER Quality value |
-20 (-2.0) |
RBS-2990 |
|||||||
|
– Downlink transport channel type |
HS-DSCH |
RBS-2991 |
|||||||
|
– DL Transport channel identity |
Not Present |
RBS-2992 |
|||||||
|
– CHOICE DL parameters |
HS-DSCH |
RBS-2993 |
|||||||
|
– HARQ Info |
RBS-2994 |
||||||||
|
– Number of Processes |
Reference to clause 6.10.2.4.5 Parameter Set |
RBS-2995 |
|||||||
|
– CHOICE Memory Partitioning |
Implicit |
RBS-2996 |
|||||||
|
– Added or reconfigured MAC-d flow |
RBS-2997 |
||||||||
|
– MAC-hs queue to add or reconfigure list |
(one queue) |
RBS-2998 |
|||||||
|
– MAC-hs queue Id |
0 |
RBS-2999 |
|||||||
|
– MAC-d Flow Identity |
0 |
RBS-3000 |
|||||||
|
– T1 |
50 |
RBS-3001 |
|||||||
|
– MAC-hs window size |
16 |
RBS-3002 |
|||||||
|
– MAC-d PDU size Info |
RBS-3003 |
||||||||
|
– MAC-d PDU size |
336 |
RBS-3004 |
|||||||
|
– MAC-d PDU size index |
0 |
RBS-3005 |
|||||||
|
– MAC-hs queue to delete list |
Not present |
RBS-3006 |
|||||||
|
– DCH quality target |
Not present |
RBS-3007 |
|||||||
|
Added or Reconfigured DL TrCH information – Downlink transport channel type – DL Transport channel identity – CHOICE DL parameters – TFS – CHOICE Transport channel type – Dynamic Transport format information – RLC Size – Number of TBs and TTI List – Transmission Time Interval – Number of Transport blocks |
A19a |
2 TrCHs (DCH for DCCH and HS-DSCH for DTCH) |
Rel-7 |
RBS-3008 RBS-3009 RBS-3010 RBS-3011 RBS-3012 RBS-3013 RBS-3014 RBS-3015 RBS-3016 RBS-3017 RBS-3018 RBS-3019 RBS-3020 RBS-3021 RBS-3022 RBS-3023 RBS-3024 RBS-3025 RBS-3026 RBS-3027 RBS-3028 RBS-3029 RBS-3030 RBS-3031 RBS-3032 RBS-3033 RBS-3034 RBS-3035 RBS-3036 RBS-3037 RBS-3038 RBS-3039 RBS-3040 RBS-3041 RBS-3042 RBS-3043 RBS-3044 |
|||||
|
DCH |
|||||||||
|
10 |
|||||||||
|
Explicit |
|||||||||
|
Dedicated transport channels |
|||||||||
|
Reference to clause 6.10 Parameter Set |
|||||||||
|
(This IE is repeated for TFI number.) |
|||||||||
|
Not Present |
|||||||||
|
Reference to clause 6.10 Parameter Set |
|||||||||
|
– CHOICE Logical channel list |
All |
||||||||
|
– Semi-static Transport Format information |
|||||||||
|
– Transmission time interval |
Reference to clause 6.10 Parameter Set |
||||||||
|
– Type of channel coding |
Reference to clause 6.10 Parameter Set |
||||||||
|
– Coding Rate |
Reference to clause 6.10 Parameter Set |
||||||||
|
– Rate matching attribute |
Reference to clause 6.10 Parameter Set |
||||||||
|
– CRC size |
Reference to clause 6.10 Parameter Set |
||||||||
|
– DCH quality target |
|||||||||
|
– BLER Quality value |
-20 (-2.0) |
||||||||
|
– Downlink transport channel type |
HS-DSCH |
||||||||
|
– DL Transport channel identity |
Not Present |
||||||||
|
– CHOICE DL parameters |
HS-DSCH |
||||||||
|
– HARQ Info |
|||||||||
|
– Number of Processes |
Reference to clause 6.10.2.4.5 Parameter Set |
||||||||
|
– CHOICE Memory Partitioning |
Implicit |
||||||||
|
– Added or reconfigured MAC-d flow |
|||||||||
|
– MAC-hs queue to add or reconfigure list |
(one queue) |
||||||||
|
– MAC-hs queue Id |
0 |
||||||||
|
– MAC-d Flow Identity |
0 |
||||||||
|
– T1 – MAC-hs window size – MAC-d PDU size Info – MAC-d PDU size – MAC-d PDU size index – MAC-hs queue to delete list – DCH quality target |
50 |
||||||||
|
16 |
|||||||||
|
336 |
|||||||||
|
0 |
|||||||||
|
Not present |
|||||||||
|
Not present |
|||||||||
|
Added or Reconfigured DL TrCH information |
A14 |
1 TrCH (HS-DSCH for DTCH and DCCH) |
Rel-6 |
RBS-3045 |
|||||
|
, A20 |
Rel-7 |
RBS-3046 |
|||||||
|
, A31, A32 |
Rel-9 |
RBS-3047 |
|||||||
|
– Downlink transport channel type |
HS-DSCH |
RBS-3048 |
|||||||
|
– DL Transport channel identity |
Not Present |
RBS-3049 |
|||||||
|
– CHOICE DL parameters |
HS-DSCH |
RBS-3050 |
|||||||
|
– HARQ Info |
RBS-3051 |
||||||||
|
– Number of Processes |
Reference to clause 6.10.2.4.5 Parameter Set |
RBS-3052 |
|||||||
|
– CHOICE Memory Partitioning |
Implicit |
RBS-3053 |
|||||||
|
– Added or reconfigured MAC-d flow |
RBS-3054 |
||||||||
|
– MAC-hs queue to add or reconfigure list |
(two queues) |
RBS-3055 |
|||||||
|
– MAC-hs queue Id |
0 (for DTCH) |
RBS-3056 |
|||||||
|
– MAC-d Flow Identity |
0 |
RBS-3057 |
|||||||
|
– T1 |
50 |
RBS-3058 |
|||||||
|
– MAC-hs window size |
16 |
RBS-3059 |
|||||||
|
– MAC-d PDU size Info |
RBS-3060 |
||||||||
|
– MAC-d PDU size |
336 |
RBS-3061 |
|||||||
|
– MAC-d PDU size index |
0 |
RBS-3062 |
|||||||
|
– MAC-hs queue Id |
1 (for DCCH) |
RBS-3063 |
|||||||
|
– MAC-d Flow Identity |
1 |
RBS-3064 |
|||||||
|
– T1 |
50 |
RBS-3065 |
|||||||
|
– MAC-hs window size |
16 |
RBS-3066 |
|||||||
|
– MAC-d PDU size Info |
RBS-3067 |
||||||||
|
– MAC-d PDU size |
148 |
RBS-3068 |
|||||||
|
– MAC-d PDU size index |
0 |
RBS-3069 |
|||||||
|
– MAC-hs queue to delete list |
Not present |
RBS-3070 |
|||||||
|
– DCH quality target |
Not present |
RBS-3071 |
|||||||
|
Added or Reconfigured DL TrCH information |
A15 |
2 TrCHs (DCH for DCCH and HS-DSCH for DTCH) |
Rel-6 |
RBS-3072 |
|||||
|
– Downlink transport channel type |
DCH |
RBS-3073 |
|||||||
|
– DL Transport channel identity |
10 |
RBS-3074 |
|||||||
|
– CHOICE DL parameters |
Explicit |
RBS-3075 |
|||||||
|
– TFS |
RBS-3076 |
||||||||
|
– CHOICE Transport channel type |
Dedicated transport channels |
RBS-3077 |
|||||||
|
– Dynamic Transport format information |
RBS-3078 |
||||||||
|
– RLC Size |
Reference to clause 6.10 Parameter Set |
RBS-3079 |
|||||||
|
– Number of TBs and TTI List |
(This IE is repeated for TFI number.) |
RBS-3080 |
|||||||
|
– Transmission Time Interval |
Not Present |
RBS-3081 |
|||||||
|
– Number of Transport blocks |
Reference to clause 6.10 Parameter Set |
RBS-3082 |
|||||||
|
– CHOICE Logical channel list |
All |
RBS-3083 |
|||||||
|
– Semi-static Transport Format information |
RBS-3084 |
||||||||
|
– Transmission time interval |
Reference to clause 6.10 Parameter Set |
RBS-3085 |
|||||||
|
– Type of channel coding |
Reference to clause 6.10 Parameter Set |
RBS-3086 |
|||||||
|
– Coding Rate |
Reference to clause 6.10 Parameter Set |
RBS-3087 |
|||||||
|
– Rate matching attribute |
Reference to clause 6.10 Parameter Set |
RBS-3088 |
|||||||
|
– CRC size |
Reference to clause 6.10 Parameter Set |
RBS-3089 |
|||||||
|
– DCH quality target |
RBS-3090 |
||||||||
|
– BLER Quality value |
-20 (-2.0) |
RBS-3091 |
|||||||
|
– Downlink transport channel type |
HS-DSCH |
RBS-3092 |
|||||||
|
– DL Transport channel identity |
Not Present |
RBS-3093 |
|||||||
|
– CHOICE DL parameters |
HS-DSCH |
RBS-3094 |
|||||||
|
– HARQ Info |
RBS-3095 |
||||||||
|
– Number of Processes |
Reference to clause 6.10.2.4.5 Parameter Set |
RBS-3096 |
|||||||
|
– CHOICE Memory Partitioning |
Implicit |
RBS-3097 |
|||||||
|
– Added or reconfigured MAC-d flow |
RBS-3098 |
||||||||
|
– MAC-hs queue to add or reconfigure list |
(two queues) |
RBS-3099 |
|||||||
|
– MAC-hs queue Id |
0 (for first DTCH) |
RBS-3100 |
|||||||
|
– MAC-d Flow Identity |
0 |
RBS-3101 |
|||||||
|
– T1 |
50 |
RBS-3102 |
|||||||
|
– MAC-hs window size |
16 |
RBS-3103 |
|||||||
|
– MAC-d PDU size Info |
RBS-3104 |
||||||||
|
– MAC-d PDU size |
336 |
RBS-3105 |
|||||||
|
– MAC-d PDU size index |
0 |
RBS-3106 |
|||||||
|
– MAC-hs queue Id |
2 (for second DTCH) |
RBS-3107 |
|||||||
|
– MAC-d Flow Identity |
2 |
RBS-3108 |
|||||||
|
– T1 |
50 |
RBS-3109 |
|||||||
|
– MAC-hs window size |
16 |
RBS-3110 |
|||||||
|
– MAC-d PDU size Info |
RBS-3111 |
||||||||
|
– MAC-d PDU size |
336 |
RBS-3112 |
|||||||
|
– MAC-d PDU size index |
0 |
RBS-3113 |
|||||||
|
– MAC-hs queue to delete list |
Not present |
RBS-3114 |
|||||||
|
– DCH quality target |
Not present |
RBS-3115 |
|||||||
|
Added or Reconfigured DL TrCH information |
A16 |
1 TrCH (HS-DSCH for 2 DTCHs and DCCH) |
Rel-6 |
RBS-3116 |
|||||
|
, A19b, A21 |
Rel-7 |
RBS-3117 |
|||||||
|
– Downlink transport channel type |
HS-DSCH |
RBS-3118 |
|||||||
|
– DL Transport channel identity |
Not Present |
RBS-3119 |
|||||||
|
– CHOICE DL parameters |
HS-DSCH |
RBS-3120 |
|||||||
|
– HARQ Info |
RBS-3121 |
||||||||
|
– Number of Processes |
Reference to clause 6.10.2.4.5 Parameter Set |
RBS-3122 |
|||||||
|
– CHOICE Memory Partitioning |
Implicit |
RBS-3123 |
|||||||
|
– Added or reconfigured MAC-d flow |
RBS-3124 |
||||||||
|
– MAC-hs queue to add or reconfigure list |
(three queues) |
RBS-3125 |
|||||||
|
– MAC-hs queue Id |
0 (for first DTCH) |
RBS-3126 |
|||||||
|
– MAC-d Flow Identity |
0 |
RBS-3127 |
|||||||
|
– T1 |
50 |
RBS-3128 |
|||||||
|
– MAC-hs window size |
16 |
RBS-3129 |
|||||||
|
– MAC-d PDU size Info |
RBS-3130 |
||||||||
|
– MAC-d PDU size |
336 |
RBS-3131 |
|||||||
|
– MAC-d PDU size index |
0 |
RBS-3132 |
|||||||
|
– MAC-hs queue Id |
1 (for DCCH) |
RBS-3133 |
|||||||
|
– MAC-d Flow Identity |
1 |
RBS-3134 |
|||||||
|
– T1 |
50 |
RBS-3135 |
|||||||
|
– MAC-hs window size |
16 |
RBS-3136 |
|||||||
|
– MAC-d PDU size Info |
RBS-3137 |
||||||||
|
– MAC-d PDU size |
148 |
RBS-3138 |
|||||||
|
– MAC-d PDU size index |
0 |
RBS-3139 |
|||||||
|
– MAC-hs queue Id |
3 (for second DTCH) |
RBS-3140 |
|||||||
|
– MAC-d Flow Identity |
3 |
RBS-3141 |
|||||||
|
– T1 |
50 |
RBS-3142 |
|||||||
|
– MAC-hs window size |
16 |
RBS-3143 |
|||||||
|
– MAC-d PDU size Info |
RBS-3144 |
||||||||
|
– MAC-d PDU size |
112 |
RBS-3145 |
|||||||
|
– MAC-d PDU size index |
0 |
RBS-3146 |
|||||||
|
– MAC-d PDU size |
144 |
RBS-3147 |
|||||||
|
– MAC-d PDU size index |
1 |
RBS-3148 |
|||||||
|
– MAC-d PDU size |
160 |
RBS-3149 |
|||||||
|
– MAC-d PDU size index |
2 |
RBS-3150 |
|||||||
|
– MAC-d PDU size |
176 |
RBS-3151 |
|||||||
|
– MAC-d PDU size index |
3 |
RBS-3152 |
|||||||
|
– MAC-d PDU size |
192 |
RBS-3153 |
|||||||
|
– MAC-d PDU size index |
4 |
RBS-3154 |
|||||||
|
– MAC-d PDU size |
224 |
RBS-3155 |
|||||||
|
– MAC-d PDU size index |
5 |
RBS-3156 |
|||||||
|
– MAC-d PDU size |
296 |
RBS-3157 |
|||||||
|
– MAC-d PDU size index |
6 |
RBS-3158 |
|||||||
|
– MAC-d PDU size |
344 |
RBS-3159 |
|||||||
|
– MAC-d PDU size index |
7 |
RBS-3160 |
|||||||
|
– MAC-hs queue to delete list |
Not present |
RBS-3161 |
|||||||
|
– DCH quality target |
Not present |
RBS-3162 |
|||||||
|
Added or Reconfigured DL TrCH information |
A17, A17a, A18 |
2 TrCHs (DCH for DCCH and HS-DSCH for DTCH) |
Rel-7 |
RBS-3163 |
|||||
|
, A25a |
Rel-8 |
RBS-3164 |
|||||||
|
– Downlink transport channel type |
DCH |
RBS-3165 |
|||||||
|
– DL Transport channel identity |
10 |
RBS-3166 |
|||||||
|
– CHOICE DL parameters |
Same as UL |
RBS-3167 |
|||||||
|
– Uplink transport channel type |
DCH |
RBS-3168 |
|||||||
|
– UL TrCH identity |
5 |
RBS-3169 |
|||||||
|
– DCH quality target |
RBS-3170 |
||||||||
|
– BLER Quality value |
-20 (-2.0) |
RBS-3171 |
|||||||
|
– Downlink transport channel type |
HS-DSCH |
RBS-3172 |
|||||||
|
– DL Transport channel identity |
Not Present |
RBS-3173 |
|||||||
|
– CHOICE DL parameters |
HS-DSCH |
RBS-3174 |
|||||||
|
– HARQ Info |
RBS-3175 |
||||||||
|
– Number of Processes |
Reference to clause 6.10.2.4.5 Parameter Set |
RBS-3176 |
|||||||
|
– CHOICE Memory Partitioning |
Implicit |
RBS-3177 |
|||||||
|
– CHOICE DL MAC header type |
MAC-ehs |
RBS-3178 |
|||||||
|
– Added or reconfigured MAC-ehs reordering queue |
RBS-3179 |
||||||||
|
– MAC-ehs queue to add or reconfigure list |
(one queue) |
RBS-3180 |
|||||||
|
– MAC-ehs queue Id |
0 |
RBS-3181 |
|||||||
|
– T1 |
50 |
RBS-3182 |
|||||||
|
– MAC-ehs window size |
16 |
RBS-3183 |
|||||||
|
– MAC-ehs queue to delete list |
Not present |
RBS-3184 |
|||||||
|
– DCH quality target |
Not present |
RBS-3185 |
|||||||
|
Added or Reconfigured DL TrCH information |
A17b, A17c, A28a A25c , A33, A34, A36, A37 |
1 TrCH (HS-DSCH for DTCH and DCCH) |
Rel-7 Rel-9 Rel-10 |
RBS-3186 |
|||||
|
– Downlink transport channel type |
HS-DSCH |
RBS-3187 |
|||||||
|
– DL Transport channel identity |
Not Present |
RBS-3188 |
|||||||
|
– CHOICE DL parameters |
HS-DSCH |
RBS-3189 |
|||||||
|
– HARQ Info |
RBS-3190 |
||||||||
|
– Number of Processes |
Reference to clause 6.10.2.4.5 Parameter Set |
RBS-3191 |
|||||||
|
– CHOICE Memory Partitioning |
Implicit |
RBS-3192 |
|||||||
|
– CHOICE DL MAC header type |
MAC-ehs |
RBS-3193 |
|||||||
|
– Added or reconfigured MAC-ehs reordering queue |
RBS-3194 |
||||||||
|
– MAC-hs queue to add or reconfigure list |
(two queues) |
RBS-3195 |
|||||||
|
– MAC-ehs queue Id |
0 (for DTCH) |
RBS-3196 |
|||||||
|
– T1 |
50 |
RBS-3197 |
|||||||
|
– MAC-ehs window size |
16 |
RBS-3198 |
|||||||
|
– MAC-ehs queue Id |
1 (for DCCH) |
RBS-3199 |
|||||||
|
– T1 |
50 |
RBS-3200 |
|||||||
|
– MAC-hs window size |
16 |
RBS-3201 |
|||||||
|
– MAC-ehs queue to delete list |
Not present |
RBS-3202 |
|||||||
|
– DCH quality target |
Not present |
RBS-3203 |
|||||||
|
Added or Reconfigured DL TrCH information |
A17d, A17e, A17f |
2 TrCHs (DCH for DCCH and HS-DSCH for DTCH) |
Rel-7 |
RBS-3204 |
|||||
|
, A25b |
Rel-8 |
RBS-3205 |
|||||||
|
– Downlink transport channel type |
DCH |
RBS-3206 |
|||||||
|
– DL Transport channel identity |
10 |
RBS-3207 |
|||||||
|
– CHOICE DL parameters |
Explicit |
RBS-3208 |
|||||||
|
– TFS |
RBS-3209 |
||||||||
|
– CHOICE Transport channel type |
Dedicated transport channels |
RBS-3210 |
|||||||
|
– Dynamic Transport format information |
RBS-3211 |
||||||||
|
– RLC Size |
Reference to clause 6.10 Parameter Set |
RBS-3212 |
|||||||
|
– Number of TBs and TTI List |
(This IE is repeated for TFI number.) |
RBS-3213 |
|||||||
|
– Transmission Time Interval |
Not Present |
RBS-3214 |
|||||||
|
– Number of Transport blocks |
Reference to clause 6.10 Parameter Set |
RBS-3215 |
|||||||
|
– CHOICE Logical channel list |
All |
RBS-3216 |
|||||||
|
– Semi-static Transport Format information |
RBS-3217 |
||||||||
|
– Transmission time interval |
Reference to clause 6.10 Parameter Set |
RBS-3218 |
|||||||
|
– Type of channel coding |
Reference to clause 6.10 Parameter Set |
RBS-3219 |
|||||||
|
– Coding Rate |
Reference to clause 6.10 Parameter Set |
RBS-3220 |
|||||||
|
– Rate matching attribute |
Reference to clause 6.10 Parameter Set |
RBS-3221 |
|||||||
|
– CRC size |
Reference to clause 6.10 Parameter Set |
RBS-3222 |
|||||||
|
– DCH quality target |
RBS-3223 |
||||||||
|
– BLER Quality value |
-20 (-2.0) |
RBS-3224 |
|||||||
|
– Downlink transport channel type |
HS-DSCH |
RBS-3225 |
|||||||
|
– DL Transport channel identity |
Not Present |
RBS-3226 |
|||||||
|
– CHOICE DL parameters |
HS-DSCH |
RBS-3227 |
|||||||
|
– HARQ Info |
RBS-3228 |
||||||||
|
– Number of Processes |
Reference to clause 6.10.2.4.5 Parameter Set |
RBS-3229 |
|||||||
|
– CHOICE Memory Partitioning |
Implicit |
RBS-3230 |
|||||||
|
– CHOICE DL MAC header type |
MAC-ehs |
RBS-3231 |
|||||||
|
– Added or reconfigured MAC-ehs reordering queue |
RBS-3232 |
||||||||
|
– MAC-ehs queue to add or reconfigure list |
(one queue) |
RBS-3233 |
|||||||
|
– MAC-ehs queue Id |
0 |
RBS-3234 |
|||||||
|
– T1 |
50 |
RBS-3235 |
|||||||
|
– MAC-ehs window size |
16 |
RBS-3236 |
|||||||
|
– MAC-ehs queue to delete list |
Not present |
RBS-3237 |
|||||||
|
– DCH quality target |
Not present |
RBS-3238 |
|||||||
|
Added or Reconfigured DL TrCH information |
A22 |
1 TrCH (HS-DSCH for 2 DTCHs and DCCH) |
Rel-7 |
RBS-3239 |
|||||
|
– Downlink transport channel type |
HS-DSCH |
RBS-3240 |
|||||||
|
– DL Transport channel identity |
Not Present |
RBS-3241 |
|||||||
|
– CHOICE DL parameters |
HS-DSCH |
RBS-3242 |
|||||||
|
– HARQ Info |
RBS-3243 |
||||||||
|
– Number of Processes |
Reference to clause 6.10.2.4.5 Parameter Set |
RBS-3244 |
|||||||
|
– CHOICE Memory Partitioning |
Implicit |
RBS-3245 |
|||||||
|
– CHOICE DL MAC header type |
MAC-ehs |
RBS-3246 |
|||||||
|
– Added or reconfigured MAC-ehs reordering queue |
RBS-3247 |
||||||||
|
– MAC-ehs queue to add or reconfigure list |
(three queues) |
RBS-3248 |
|||||||
|
– MAC-ehs queue Id |
0 (for first DTCH) |
RBS-3249 |
|||||||
|
– T1 |
50 |
RBS-3250 |
|||||||
|
– MAC-ehs window size |
16 |
RBS-3251 |
|||||||
|
– MAC-ehs queue Id |
1 (for DCCH) |
RBS-3252 |
|||||||
|
– T1 |
50 |
RBS-3253 |
|||||||
|
– MAC-ehs window size |
16 |
RBS-3254 |
|||||||
|
– MAC-ehs queue Id |
3 (for second DTCH) |
RBS-3255 |
|||||||
|
– T1 |
50 |
RBS-3256 |
|||||||
|
– MAC-ehs window size |
16 |
RBS-3257 |
|||||||
|
– MAC-ehs queue to delete list |
Not present |
RBS-3258 |
|||||||
|
– DCH quality target |
Not present |
RBS-3259 |
|||||||
|
Added or Reconfigured DL TrCH information |
A23 |
1 TrCH (HS-DSCH for DTCHs and DCCH) |
Rel-7 Rel-8 |
RBS-3260 |
|||||
|
– Downlink transport channel type |
HS-DSCH |
RBS-3261 |
|||||||
|
– DL Transport channel identity |
Not Present |
RBS-3262 |
|||||||
|
– CHOICE DL parameters |
HS-DSCH |
RBS-3263 |
|||||||
|
– HARQ Info |
RBS-3264 |
||||||||
|
– Number of Processes |
Reference to clause 6.10 Parameter Set |
RBS-3265 |
|||||||
|
– CHOICE Memory Partitioning |
Implicit |
RBS-3266 |
|||||||
|
– CHOICE DL MAC header type |
MAC-ehs |
RBS-3267 |
|||||||
|
– Added or reconfigured MAC-ehs reordering queue |
RBS-3268 |
||||||||
|
– MAC-ehs queue to add or reconfigure list |
(two queues) |
RBS-3269 |
|||||||
|
– MAC-ehs queue Id |
0 (for DTCH) |
RBS-3270 |
|||||||
|
– T1 |
50 |
RBS-3271 |
|||||||
|
– MAC-ehs window size |
16 |
RBS-3272 |
|||||||
|
– MAC-ehs queue Id |
1 (for DCCH) |
RBS-3273 |
|||||||
|
– T1 |
50 |
RBS-3274 |
|||||||
|
– MAC-ehs window size |
16 |
RBS-3275 |
|||||||
|
– MAC-ehs queue to delete list |
Not present |
RBS-3276 |
|||||||
|
– DCH quality target |
Not present |
RBS-3277 |
|||||||
|
Added or Reconfigured DL TrCH information |
A25 |
1 TrCH (HS-DSCH for DTCH and DCCH) |
Rel-8 |
RBS-3278 |
|||||
|
– Downlink transport channel type |
HS-DSCH |
RBS-3279 |
|||||||
|
– DL Transport channel identity |
Not Present |
RBS-3280 |
|||||||
|
– CHOICE DL parameters |
HS-DSCH |
RBS-3281 |
|||||||
|
– HARQ Info |
RBS-3282 |
||||||||
|
– Number of Processes |
Reference to clause 6.10.2.4.5 Parameter Set |
RBS-3283 |
|||||||
|
– CHOICE Memory Partitioning |
Implicit |
RBS-3284 |
|||||||
|
– CHOICE DL MAC header type |
MAC-ehs |
RBS-3285 |
|||||||
|
– Added or reconfigured MAC-ehs reordering queue |
RBS-3286 |
||||||||
|
– MAC-ehs queue to add or reconfigure list |
(two queues) |
RBS-3287 |
|||||||
|
– MAC-ehs queue Id |
0 (for DTCH) |
RBS-3288 |
|||||||
|
– T1 |
50 |
RBS-3289 |
|||||||
|
– MAC-ehs window size |
16 |
RBS-3290 |
|||||||
|
– MAC-ehs queue Id |
1 (for DCCH) |
RBS-3291 |
|||||||
|
– T1 |
50 |
RBS-3292 |
|||||||
|
– MAC-ehs window size |
16 |
RBS-3293 |
|||||||
|
– MAC-ehs queue to delete list |
Not present |
RBS-3294 |
|||||||
|
– DCH quality target |
Not present |
RBS-3295 |
|||||||
|
Added or Reconfigured DL TrCH information |
A28 |
2 TrCHs (DCH for DCCH and HS-DSCH for DTCH) |
Rel-8 |
RBS-3296 |
|||||
|
– Downlink transport channel type |
DCH |
RBS-3297 |
|||||||
|
– DL Transport channel identity |
10 |
RBS-3298 |
|||||||
|
– CHOICE DL parameters |
Same as UL |
RBS-3299 |
|||||||
|
– Uplink transport channel type |
DCH |
RBS-3300 |
|||||||
|
– UL TrCH identity |
5 |
RBS-3301 |
|||||||
|
– DCH quality target |
RBS-3302 |
||||||||
|
– BLER Quality value |
-20 (-2.0) |
RBS-3303 |
|||||||
|
– Downlink transport channel type |
HS-DSCH |
RBS-3304 |
|||||||
|
– DL Transport channel identity |
Not Present |
RBS-3305 |
|||||||
|
– CHOICE DL parameters |
HS-DSCH |
RBS-3306 |
|||||||
|
– HARQ Info |
RBS-3307 |
||||||||
|
– Number of Processes |
Reference to clause 6.10.2.4.5 Parameter Set |
RBS-3308 |
|||||||
|
– CHOICE Memory Partitioning |
Implicit |
RBS-3309 |
|||||||
|
– CHOICE DL MAC header type |
MAC-ehs |
RBS-3310 |
|||||||
|
– Added or reconfigured MAC-ehs reordering queue |
RBS-3311 |
||||||||
|
– MAC-ehs queue to add or reconfigure list |
(one queue) |
RBS-3312 |
|||||||
|
– MAC-ehs queue Id |
0 |
RBS-3313 |
|||||||
|
– T1 |
50 |
RBS-3314 |
|||||||
|
– MAC-ehs window size |
32 |
RBS-3315 |
|||||||
|
– MAC-ehs queue to delete list |
Not present |
RBS-3316 |
|||||||
|
– DCH quality target |
Not present |
RBS-3317 |
|||||||
|
Added or Reconfigured DL TrCH information list |
A24, A29 |
1 TrCH (HS-DSCH for DTCH) |
RBS-3318 |
||||||
|
– Downlink transport channel type |
HS-DSCH |
RBS-3319 |
|||||||
|
– DL Transport channel identity |
Not Present |
RBS-3320 |
|||||||
|
– CHOICE DL parameters |
HS-DSCH |
RBS-3321 |
|||||||
|
– HARQ Info |
RBS-3322 |
||||||||
|
– Number of Processes |
Reference to clause 6.10 Parameter Set |
RBS-3323 |
|||||||
|
– CHOICE Memory Partitioning |
Implicit |
RBS-3324 |
|||||||
|
– CHOICE DL MAC header type |
MAC-ehs |
RBS-3325 |
|||||||
|
– Added or reconfigured MAC-ehs reordering queue |
RBS-3326 |
||||||||
|
– MAC-ehs queue to add or reconfigure list |
(one queue) |
RBS-3327 |
|||||||
|
– MAC-ehs queue Id |
2 (for DTCH) |
RBS-3328 |
|||||||
|
– T1 |
50 |
RBS-3329 |
|||||||
|
– MAC-ehs window size |
16 |
RBS-3330 |
|||||||
|
– DCH quality target |
Not present |
RBS-3331 |
|||||||
|
Added or Reconfigured DL TrCH information |
A26 |
2 TrCHs (DCH for DCCH and HS-DSCH for 3 DTCHs) |
Rel-8 |
RBS-3332 |
|||||
|
– Downlink transport channel type |
DCH |
RBS-3333 |
|||||||
|
– DL Transport channel identity |
10 |
RBS-3334 |
|||||||
|
– CHOICE DL parameters |
Explicit |
RBS-3335 |
|||||||
|
– TFS |
RBS-3336 |
||||||||
|
– CHOICE Transport channel type |
Dedicated transport channels |
RBS-3337 |
|||||||
|
– Dynamic Transport format information |
RBS-3338 |
||||||||
|
– RLC Size |
Reference to clause 6.10 Parameter Set |
RBS-3339 |
|||||||
|
– Number of TBs and TTI List |
(This IE is repeated for TFI number.) |
RBS-3340 |
|||||||
|
– Transmission Time Interval |
Not Present |
RBS-3341 |
|||||||
|
– Number of Transport blocks |
Reference to clause 6.10 Parameter Set |
RBS-3342 |
|||||||
|
– CHOICE Logical channel list |
All |
RBS-3343 |
|||||||
|
– Semi-static Transport Format information |
RBS-3344 |
||||||||
|
– Transmission time interval |
Reference to clause 6.10 Parameter Set |
RBS-3345 |
|||||||
|
– Type of channel coding |
Reference to clause 6.10 Parameter Set |
RBS-3346 |
|||||||
|
– Coding Rate |
Reference to clause 6.10 Parameter Set |
RBS-3347 |
|||||||
|
– Rate matching attribute |
Reference to clause 6.10 Parameter Set |
RBS-3348 |
|||||||
|
– CRC size |
Reference to clause 6.10 Parameter Set |
RBS-3349 |
|||||||
|
– DCH quality target |
RBS-3350 |
||||||||
|
– BLER Quality value |
-20 (-2.0) |
RBS-3351 |
|||||||
|
– Downlink transport channel type |
HS-DSCH |
RBS-3352 |
|||||||
|
– DL Transport channel identity |
Not Present |
RBS-3353 |
|||||||
|
– CHOICE DL parameters |
HS-DSCH |
RBS-3354 |
|||||||
|
– HARQ Info |
RBS-3355 |
||||||||
|
– Number of Processes |
Reference to clause 6.10.2.4.5 Parameter Set |
RBS-3356 |
|||||||
|
– CHOICE Memory Partitioning |
Implicit |
RBS-3357 |
|||||||
|
– CHOICE DL MAC header type |
MAC-ehs |
RBS-3358 |
|||||||
|
– Added or reconfigured MAC-ehs reordering queue |
RBS-3359 |
||||||||
|
– MAC-ehs queue to add or reconfigure list |
(three queues) |
RBS-3360 |
|||||||
|
RBS-3361 |
|||||||||
|
– MAC-ehs queue Id |
2 (for first DTCH) |
RBS-3362 |
|||||||
|
– T1 |
50 |
RBS-3363 |
|||||||
|
– MAC-ehs window size |
16 |
RBS-3364 |
|||||||
|
– MAC-ehs queue Id |
3 (for second DTCH) |
RBS-3365 |
|||||||
|
– T1 |
50 |
RBS-3366 |
|||||||
|
– MAC-ehs window size |
16 |
RBS-3367 |
|||||||
|
– MAC-ehs queue Id |
4 (for third DTCH) |
RBS-3368 |
|||||||
|
– T1 |
50 |
RBS-3369 |
|||||||
|
– MAC-ehs window size |
16 |
RBS-3370 |
|||||||
|
– DCH quality target |
Not present |
RBS-3371 |
|||||||
|
Added or Reconfigured DL TrCH information |
A27, A27a |
1 TrCH (HS-DSCH for 2 DTCHs and DCCH) |
Rel-8 |
RBS-3372 |
|||||
|
– Downlink transport channel type |
HS-DSCH |
RBS-3373 |
|||||||
|
– DL Transport channel identity |
Not Present |
RBS-3374 |
|||||||
|
– CHOICE DL parameters |
HS-DSCH |
RBS-3375 |
|||||||
|
– HARQ Info |
RBS-3376 |
||||||||
|
– Number of Processes |
Reference to clause 6.10.2.4.5 Parameter Set |
RBS-3377 |
|||||||
|
– CHOICE Memory Partitioning |
Implicit |
RBS-3378 |
|||||||
|
– CHOICE DL MAC header type |
MAC-ehs |
RBS-3379 |
|||||||
|
– Added or reconfigured MAC-ehs reordering queue |
RBS-3380 |
||||||||
|
– MAC-ehs queue to add or reconfigure list |
(two queues) |
RBS-3381 |
|||||||
|
– MAC-ehs queue Id |
0 (for first DTCH) |
RBS-3382 |
|||||||
|
– T1 |
50 |
RBS-3383 |
|||||||
|
– MAC-ehs window size |
16 |
RBS-3384 |
|||||||
|
– MAC-ehs queue Id |
1 (for DCCH) |
RBS-3385 |
|||||||
|
– T1 |
50 |
RBS-3386 |
|||||||
|
– MAC-ehs window size |
16 |
RBS-3387 |
|||||||
|
– DCH quality target |
Not present |
RBS-3388 |
|||||||
|
Added or Reconfigured DL TrCH information |
A30 |
1 TrCH (HS-DSCH for DTCH and DCCH) |
Rel-8 |
RBS-3389 |
|||||
|
– Downlink transport channel type |
HS-DSCH |
RBS-3390 |
|||||||
|
– DL Transport channel identity |
Not Present |
RBS-3391 |
|||||||
|
– CHOICE DL parameters |
HS-DSCH |
RBS-3392 |
|||||||
|
– HARQ Info |
RBS-3393 |
||||||||
|
– Number of Processes |
Reference to clause 6.10.2.4.5 Parameter Set |
RBS-3394 |
|||||||
|
– CHOICE Memory Partitioning |
Implicit |
RBS-3395 |
|||||||
|
– CHOICE DL MAC header type |
MAC-ehs |
RBS-3396 |
|||||||
|
– Added or reconfigured MAC-ehs reordering queue |
RBS-3397 |
||||||||
|
– MAC-hs queue to add or reconfigure list |
(two queues) |
RBS-3398 |
|||||||
|
– MAC-ehs queue Id |
2 (for DTCH) |
RBS-3399 |
|||||||
|
– T1 |
50 |
RBS-3400 |
|||||||
|
– MAC-ehs window size |
16 |
RBS-3401 |
|||||||
|
– MAC-ehs queue Id |
3 (for DCCH) |
RBS-3402 |
|||||||
|
– T1 |
50 |
RBS-3403 |
|||||||
|
– MAC-hs window size |
16 |
RBS-3404 |
|||||||
|
– MAC-ehs queue to delete list |
Not present |
RBS-3405 |
|||||||
|
– DCH quality target |
Not present |
RBS-3406 |
|||||||
|
Added or Reconfigured DL TrCH information list |
A35 A38, A39, A40, A41, A42, A43, A44, A45 |
2 TrCh (DCH for DCCH and HS-DSCH for DTCH) |
Rel-10 Rel-11 |
RBS-3407 |
|||||
|
– Downlink transport channel type |
DCH |
RBS-3408 |
|||||||
|
– DL Transport channel identity |
10 |
RBS-3409 |
|||||||
|
– CHOICE DL parameters |
Same as UL |
RBS-3410 |
|||||||
|
– Uplink transport channel type |
DCH |
RBS-3411 |
|||||||
|
– UL TrCH identity |
5 |
RBS-3412 |
|||||||
|
A33, A34, A35, A36, A37 |
Rel-10 |
RBS-3412a |
|||||||
|
– DCH quality target |
RBS-3413 |
||||||||
|
– Downlink transport channel type |
HS-DSCH |
RBS-3414 |
|||||||
|
– DL Transport channel identity |
Not Present |
RBS-3415 |
|||||||
|
– CHOICE DL parameters |
HS-DSCH |
RBS-3416 |
|||||||
|
– HARQ Info |
RBS-3417 |
||||||||
|
– Number of Processes |
Reference to clause 6.10 Parameter Set |
RBS-3418 |
|||||||
|
– CHOICE Memory Partitioning |
Implicit |
RBS-3419 |
|||||||
|
– CHOICE DL MAC header type |
MAC-ehs |
RBS-3420 |
|||||||
|
– Added or reconfigured MAC-ehs reordering queue |
RBS-3421 |
||||||||
|
– MAC-ehs queue to add or reconfigure list |
(one queue) |
RBS-3422 |
|||||||
|
– MAC-ehs queue Id |
0 (for DTCH) |
RBS-3423 |
|||||||
|
– T1 |
50 |
RBS-3424 |
|||||||
|
– MAC-ehs window size |
64 |
RBS-3425 |
|||||||
|
– DCH quality target |
Not present |
RBS-3426 |
|||||||
|
Frequency info |
A1, A2, A3, A4, A5, A7, A8, 11 |
RBS-3438 |
|||||||
|
, A9, A10 |
Rel-5 |
RBS-3439 |
|||||||
|
, A12, A13, A14, A15, A16 |
Rel-6 |
RBS-3440 |
|||||||
|
, A17, A17a, A17b, A17c, A17d, A17e, , A17f A18, A19, A19a, A19b, A20, A21, A22, A24 |
Rel-7 |
RBS-3441 |
|||||||
|
, A23, A28a |
Rel-7 |
RBS-3442 |
|||||||
|
, A25, A25a, A25b, A26, A27, A27a, A28, A30 |
Rel-8 |
RBS-3443 |
|||||||
|
, A25c |
Rel-9 |
RBS-3444 |
|||||||
|
– UARFCN uplink (Nu) |
Reference to clause 5.1 Test frequencies. This IE should be present, if the default duplex distance defined for the operating frequency band is not used and frequency is different from the current frequency, otherwise set to Not Present. |
RBS-3445 |
|||||||
|
– UARFCN downlink (Nd) |
Reference to clause 5.1 Test frequencies if frequency is different from the current frequency otherwise set to Not Present. |
RBS-3446 |
|||||||
|
Frequency info |
A6 |
Not Present |
RBS-3447 |
||||||
|
, A29 |
Rel-8 |
RBS-3448 |
|||||||
|
, A31, A32 , A33, A34, A35, A36, A37 A38, A39, A40, A41, A42, A43, A44, A45 |
Rel-9 Rel-10 Rel-11 |
RBS-3449 |
|||||||
|
DTX-DRX timing information |
A20, A21 |
Rel-7 |
RBS-3450 |
||||||
|
, A23 |
Rel-7 Rel-8 |
RBS-3451 |
|||||||
|
CHOICE timing |
RBS-3452 |
||||||||
|
– New timing |
RBS-3453 |
||||||||
|
– Enabling Delay |
0 |
RBS-3454 |
|||||||
|
– UE DTX DRX Offset |
1 if 2ms TTI selected, otherwise 0 |
RBS-3455 |
|||||||
|
DTX-DRX Information |
RBS-3456 |
||||||||
|
– CHOICE E-DCH TTI length |
Unless stated otherwise, this should be set to 2ms if the UE supports 2ms TTI, or 10ms if the UE does not support 2ms TTI. |
RBS-3457 |
|||||||
|
– UE DTX cycle 1 |
8 if 2ms TTI selected, otherwise 10 |
RBS-3458 |
|||||||
|
– UE DTX cycle 2 |
16 if 2ms TTI selected, otherwise 20 |
RBS-3459 |
|||||||
|
– MAC DTX cycle |
8 if 2ms TTI selected, otherwise 10 |
RBS-3460 |
|||||||
|
– Inactivity Threshold for UE DTX cycle 2 |
32 if 2ms TTI selected, otherwise 8 |
RBS-3461 |
|||||||
|
– UE DTX long preamble length |
4 |
RBS-3462 |
|||||||
|
– MAC Inactivity Threshold |
1 if 2ms TTI selected, otherwise 8 |
RBS-3463 |
|||||||
|
– CQI DTX Timer |
32 |
RBS-3464 |
|||||||
|
– UE DPCCH burst_1 |
1 |
RBS-3465 |
|||||||
|
– UE DPCCH burst_2 |
1 |
RBS-3466 |
|||||||
|
DRX Information |
RBS-3467 |
||||||||
|
– UE DRX cycle |
8 if 2ms TTI selected, otherwise 10 |
RBS-3468 |
|||||||
|
– Inactivity Threshold for UE DRX cycle |
32 |
RBS-3469 |
|||||||
|
– Inactivity Threshold for UE Grant Monitoring |
32 if 2ms TTI selected, otherwise 8 |
RBS-3470 |
|||||||
|
– UE DRX Grant Monitoring |
TRUE |
RBS-3471 |
|||||||
|
Uplink DPCCH slot format information |
1 |
RBS-3472 |
|||||||
|
HS-SCCH less information |
Not Present |
RBS-3473 |
|||||||
|
MIMO parameters |
A28a , A28 |
Rel-7 Rel-8 |
RBS-3474 |
||||||
|
– MIMO operation |
start |
RBS-3475 |
|||||||
|
– CHOICE mode |
FDD |
RBS-3476 |
|||||||
|
– MIMO N_cqi_typeA/M_cqi ratio |
1/1 |
RBS-3477 |
|||||||
|
– MIMO pilot configuration |
RBS-3478 |
||||||||
|
– CHOICE Second CPICH pattern |
Antenna1 S-CPICH |
RBS-3479 |
|||||||
|
– Channelisation code |
12 |
RBS-3480 |
|||||||
|
MIMO parameters |
A31 , A34 |
Rel-9 Rel-10 |
RBS-3481 |
||||||
|
– MIMO operation |
start |
RBS-3482 |
|||||||
|
– CHOICE mode |
FDD |
RBS-3483 |
|||||||
|
– MIMO N_cqi_typeA/M_cqi ratio |
1/1 |
RBS-3484 |
|||||||
|
– MIMO pilot configuration |
RBS-3485 |
||||||||
|
-CHOICE Second CPICH pattern |
Antenna1 S-CPICH |
RBS-3486 |
|||||||
|
– Channelisation code |
13 |
RBS-3487 |
|||||||
|
– Power Offset for S-CPICH for MIMO |
0 |
RBS-3488 |
|||||||
|
– Precoding weight set restriction |
True |
RBS-3489 |
|||||||
|
MIMO parameters |
A32, A33 |
Rel-9 Rel-10 |
RBS-3490 |
||||||
|
– MIMO operation |
start |
RBS-3491 |
|||||||
|
– CHOICE mode |
FDD |
RBS-3492 |
|||||||
|
– MIMO N_cqi_typeA/M_cqi ratio |
1/1 |
RBS-3493 |
|||||||
|
– MIMO pilot configuration |
RBS-3494 |
||||||||
|
-CHOICE Second CPICH pattern |
Antenna1 S-CPICH |
RBS-3495 |
|||||||
|
– Channelisation code |
29 |
RBS-3496 |
|||||||
|
– Power Offset for S-CPICH for MIMO |
0 |
RBS-3497 |
|||||||
|
– Precoding weight set restriction |
True |
RBS-3498 |
|||||||
|
Maximum allowed UL TX power |
A1, A2, A3, A4, A7, A8, A11 |
33dBm |
RBS-3499 |
||||||
|
, A9, A10 |
Rel-5 |
RBS-3500 |
|||||||
|
, A12, A13, A14, A15, A16 |
Rel-6 |
RBS-3501 |
|||||||
|
, A17, A17a, A17b, A17c, A17d, A17e, , A17f A18, A19, A19a, A19b, A20, A21, A22, A24 |
Rel-7 |
RBS-3502 |
|||||||
|
, A23, A28a |
Rel-7 Rel-8 |
RBS-3503 |
|||||||
|
, A25, A25a, A25b, A26, A27, A27a, A28, A29, A30 |
Rel-8 |
RBS-3504 |
|||||||
|
, A25c |
Rel-9 |
RBS-3505 |
|||||||
|
, A33, A34, A35, A36, A37 A38, A39, A40, A41, A42, A43, A44, A45 |
Rel-10 Rel-11 |
RBS-3506 |
|||||||
|
Maximum allowed UL TX power |
A5, A6 |
Not Present |
RBS-3507 |
||||||
|
CHOICE channel requirement |
A1, A2, A3, A4, A7, A8, A11 |
Uplink DPCH info |
Rel-5 and earlier |
RBS-3508 |
|||||
|
– Uplink DPCH power control info |
RBS-3509 |
||||||||
|
– DPCCH power offset |
-40 (-80dB) |
RBS-3510 |
|||||||
|
– PC Preamble |
1 frame |
RBS-3511 |
|||||||
|
– SRB delay |
7 frames |
RBS-3512 |
|||||||
|
– Power Control Algorithm |
Algorithm1 |
RBS-3513 |
|||||||
|
– TPC step size |
0 (1dB) |
RBS-3514 |
|||||||
|
– NACK |
Not Present |
Rel-5 |
RBS-3515 |
||||||
|
– NACK |
Not Present |
Rel-5 |
RBS-3516 |
||||||
|
– Ack-Nack repetition factor |
Not Present |
Rel-5 |
RBS-3517 |
||||||
|
– Scrambling code type |
Long |
RBS-3518 |
|||||||
|
– Scrambling code number |
0 (0 to 16777215) |
RBS-3519 |
|||||||
|
– Number of DPDCH |
Not Present(1) |
RBS-3520 |
|||||||
|
– spreading factor |
Reference to clause 6.10 Parameter Set |
RBS-3521 |
|||||||
|
– TFCI existence |
Reference to clause 6.10 Parameter Set |
RBS-3522 |
|||||||
|
– Number of FBI bit |
Reference to clause 6.10 Parameter Set |
RBS-3523 |
|||||||
|
– Puncturing Limit |
Reference to clause 6.10 Parameter Set |
RBS-3524 |
|||||||
|
– Number of TPC bits |
Not Present |
Rel-7 |
RBS-3525 |
||||||
|
CHOICE channel requirement |
A9, A10 |
Uplink DPCH info |
Rel-5 |
RBS-3526 |
|||||
|
, A17, A17a, A18 |
Rel-7 |
RBS-3527 |
|||||||
|
, A25a, A28 |
Rel-8 |
RBS-3528 |
|||||||
|
– Uplink DPCH power control info |
|
RBS-3529 |
|||||||
|
– DPCCH power offset |
-40 (-80dB) |
RBS-3530 |
|||||||
|
– PC Preamble |
1 frame |
RBS-3531 |
|||||||
|
– SRB delay |
7 frames |
RBS-3532 |
|||||||
|
– Power Control Algorithm |
Algorithm1 |
RBS-3533 |
|||||||
|
– TPC step size |
0 (1dB) |
RBS-3534 |
|||||||
|
– ACK |
3 |
RBS-3535 |
|||||||
|
– NACK |
3 |
RBS-3536 |
|||||||
|
– Ack-Nack repetition factor |
1 |
RBS-3537 |
|||||||
|
– HARQ_preamble_mode |
0 |
Rel-6 |
RBS-3538 |
||||||
|
– Scrambling code type |
Long |
RBS-3539 |
|||||||
|
– Scrambling code number |
0 (0 to 16777215) |
RBS-3540 |
|||||||
|
– Number of DPDCH |
Not Present(1) |
RBS-3541 |
|||||||
|
– spreading factor |
Reference to clause 6.10 Parameter Set |
RBS-3542 |
|||||||
|
– TFCI existence |
Reference to clause 6.10 Parameter Set |
RBS-3543 |
|||||||
|
– Number of FBI bit |
Reference to clause 6.10 Parameter Set |
RBS-3544 |
|||||||
|
– Puncturing Limit |
Reference to clause 6.10 Parameter Set |
RBS-3545 |
|||||||
|
CHOICE channel requirement |
A5,A6 |
Not Present |
Rel-5 and earlier |
RBS-3546 |
|||||
|
Uplink DPCH info |
A12 |
Rel-6 |
RBS-3547 |
||||||
|
, A19 A35 A38, A39, A40, A41, A42, A43, A44, A45 |
Rel-7 Rel-10 Rel-11 |
RBS-3548 |
|||||||
|
– Uplink DPCH power control info |
RBS-3549 |
||||||||
|
– DPCCH power offset |
-40 (-80dB) |
RBS-3550 |
|||||||
|
– PC Preamble |
1 frame |
RBS-3551 |
|||||||
|
– SRB delay |
7 frames |
RBS-3552 |
|||||||
|
– Power Control Algorithm |
Algorithm1 |
RBS-3553 |
|||||||
|
– TPC step size |
0 (1dB) |
RBS-3554 |
|||||||
|
– ACK |
3 |
RBS-3555 |
|||||||
|
– NACK |
3 |
RBS-3556 |
|||||||
|
– Ack-Nack repetition factor |
1 |
RBS-3557 |
|||||||
|
– HARQ_preamble_mode |
0 |
RBS-3558 |
|||||||
|
– Scrambling code type |
Long |
RBS-3559 |
|||||||
|
– Scrambling code number |
0 (0 to 16777215) |
RBS-3560 |
|||||||
|
– Number of DPDCH |
Not Present(1) |
RBS-3561 |
|||||||
|
– spreading factor |
Reference to clause 6.10 Parameter Set |
RBS-3562 |
|||||||
|
– TFCI existence |
Reference to clause 6.10 Parameter Set |
RBS-3563 |
|||||||
|
– Number of FBI bit |
Reference to clause 6.10 Parameter Set |
RBS-3564 |
|||||||
|
– Puncturing Limit |
Reference to clause 6.10 Parameter Set |
RBS-3565 |
|||||||
|
– Number of TPC bits |
Not Present |
Rel-7 |
RBS-3566 |
||||||
|
Uplink DPCH info |
A13, A14, A15, A16 |
Rel-6 |
RBS-3567 |
||||||
|
, A17b, A17c, A17d, A17e, , A17f A19a, A19b, A20, A21, A22 |
Rel-7 |
RBS-3568 |
|||||||
|
, A23, A28a |
Rel-7 Rel-8 |
RBS-3569 |
|||||||
|
, A25, A25b, A26, A27, A27a, A30 |
Rel-8 |
RBS-3570 |
|||||||
|
, A25c A33, A34, A36, A37 |
Rel-9 Rel-10 |
RBS-3571 |
|||||||
|
– Uplink DPCH power control info |
RBS-3572 |
||||||||
|
– DPCCH power offset |
-40 (-80dB) |
RBS-3573 |
|||||||
|
– PC Preamble |
1 frame |
RBS-3574 |
|||||||
|
– SRB delay |
7 frames |
RBS-3575 |
|||||||
|
– Power Control Algorithm |
Algorithm1 |
RBS-3576 |
|||||||
|
– TPC step size |
0 (1dB) |
RBS-3577 |
|||||||
|
– ACK |
3 |
RBS-3578 |
|||||||
|
– NACK |
3 |
RBS-3579 |
|||||||
|
– Ack-Nack repetition factor |
1 |
RBS-3580 |
|||||||
|
– HARQ_preamble_mode |
0 |
RBS-3581 |
|||||||
|
– Scrambling code type |
Long |
RBS-3582 |
|||||||
|
– Scrambling code number |
0 (0 to 16777215) |
RBS-3583 |
|||||||
|
– Number of DPDCH |
0 |
RBS-3584 |
|||||||
|
– spreading factor |
Not Present |
RBS-3585 |
|||||||
|
– TFCI existence |
FALSE |
RBS-3586 |
|||||||
|
– Number of FBI bit |
Not Present |
RBS-3587 |
|||||||
|
– Puncturing Limit |
Not Present |
RBS-3588 |
|||||||
|
– Number of TPC bits |
Not Present |
Rel-7 |
RBS-3589 |
||||||
|
Uplink DPCH info |
A24, A29 |
Not Present |
Rel-7 |
RBS-3590 |
|||||
|
Uplink DPCH info |
A31, A32 |
Rel-9 |
RBS-3591 |
||||||
|
– Uplink DPCH power control info |
RBS-3592 |
||||||||
|
– DPCCH power offset |
-40 (-80dB) |
RBS-3593 |
|||||||
|
– PC Preamble |
1 frame |
RBS-3594 |
|||||||
|
– SRB delay |
7 frames |
RBS-3595 |
|||||||
|
– Power Control Algorithm |
Algorithm1 |
RBS-3596 |
|||||||
|
– TPC step size |
0 (1dB) |
RBS-3597 |
|||||||
|
– ∆ACK |
3 |
RBS-3598 |
|||||||
|
– ∆NACK |
3 |
RBS-3599 |
|||||||
|
– Ack-Nack repetition factor |
1 |
RBS-3600 |
|||||||
|
– HARQ_preamble_mode |
0 |
RBS-3601 |
|||||||
|
– Scrambling code type |
Short |
RBS-3602 |
|||||||
|
– Scrambling code number |
0 (0 to 16777215) |
RBS-3603 |
|||||||
|
– Number of DPDCH |
Not Present(1) |
RBS-3604 |
|||||||
|
– spreading factor |
Reference to clause 6.10 Parameter Set |
RBS-3605 |
|||||||
|
– TFCI existence |
Reference to clause 6.10 Parameter Set |
RBS-3606 |
|||||||
|
– Number of FBI bit |
Reference to clause 6.10 Parameter Set |
RBS-3607 |
|||||||
|
– Puncturing Limit |
Reference to clause 6.10 Parameter Set |
RBS-3608 |
|||||||
|
– Number of TPC bits |
Not Present |
RBS-3609 |
|||||||
|
E-DCH info |
A12, A13, A14, A15, A16 |
Rel-6 |
RBS-3610 |
||||||
|
, A17b, A17c, A17d, A17e, , A17f A20, A21, A22 |
Rel-7 |
RBS-3611 |
|||||||
|
, A23 |
Rel-7 Rel-8 |
RBS-3612 |
|||||||
|
, A25, A25b, A26, A27, A30 |
Rel-8 |
RBS-3613 |
|||||||
|
, A25c , A33, A34, A35, A36, A37 A38, A39, A40, A41, A42, A43, A44, A45 |
Rel-9 Rel-10 Rel-11 |
RBS-3614 |
|||||||
|
– MAC- e/es reset indicator |
TRUE |
RBS-3615 |
|||||||
|
– E-DPCCH info |
RBS-3616 |
||||||||
|
– E-DPCCH/DPCCH power offset |
0 |
RBS-3617 |
|||||||
|
– Happy bit delay condition |
100 ms |
RBS-3618 |
|||||||
|
– E-TFC Boost Info |
Not Present |
Rel-7 |
RBS-3619 |
||||||
|
– E-DPDCH power interpolation |
Not Present |
Rel-7 |
RBS-3620 |
||||||
|
– E-DPDCH info |
RBS-3621 |
||||||||
|
– E-TFCI table index |
0 |
RBS-3622 |
|||||||
|
– E-DCH minimum set E-TFCI |
9 |
RBS-3623 |
|||||||
|
– Reference E-TFCIs |
2 E-TFCIs |
RBS-3624 |
|||||||
|
– Reference E-TFCI |
11 |
RBS-3625 |
|||||||
|
– Reference E-TFCI PO |
4 |
RBS-3626 |
|||||||
|
– Reference E-TFCI |
83 |
RBS-3627 |
|||||||
|
– Reference E-TFCI PO |
16 |
RBS-3628 |
|||||||
|
– Maximum channelisation codes |
2sf4 |
RBS-3629 |
|||||||
|
– PLnon-max |
0.84 |
RBS-3630 |
|||||||
|
– Scheduling Information Configuration |
RBS-3631 |
||||||||
|
– Periodicity for Scheduling Info – no grant |
Not present |
RBS-3632 |
|||||||
|
– Periodicity for Scheduling Info – grant |
Not present |
RBS-3633 |
|||||||
|
– Power Offset for Scheduling Info |
0 |
RBS-3634 |
|||||||
|
– 3-Index-Step Threshold |
Not present |
RBS-3635 |
|||||||
|
– 2-Index-Step Threshold |
Not present |
RBS-3636 |
|||||||
|
– Scheduled Transmission configuration |
RBS-3637 |
||||||||
|
– 2ms scheduled transmission grant HARQ process allocation |
Not present |
RBS-3638 |
|||||||
|
– Serving Grant |
Not present |
RBS-3639 |
|||||||
|
-UL 16QAM settings |
Not Present |
Rel-7 |
RBS-3640 |
||||||
|
E-DCH info |
A19 |
Rel-7 |
RBS-3641 |
||||||
|
, A27a |
Rel-8 |
RBS-3642 |
|||||||
|
– MAC- e/es reset indicator |
TRUE |
RBS-3643 |
|||||||
|
– E-DPCCH info |
RBS-3644 |
||||||||
|
– E-DPCCH/DPCCH power offset |
0 |
RBS-3645 |
|||||||
|
– Happy bit delay condition |
100 ms |
RBS-3646 |
|||||||
|
– E-TFC Boost Info |
Not Present |
Rel-7 |
RBS-3647 |
||||||
|
– E-DPDCH power interpolation |
Not Present |
Rel-7 |
RBS-3648 |
||||||
|
– E-DPDCH info |
RBS-3649 |
||||||||
|
– E-TFCI table index |
0 |
RBS-3650 |
|||||||
|
– E-DCH minimum set E-TFCI |
9 |
RBS-3651 |
|||||||
|
– Reference E-TFCIs |
2 E-TFCIs |
RBS-3652 |
|||||||
|
– Reference E-TFCI |
11 |
RBS-3653 |
|||||||
|
– Reference E-TFCI PO |
4 |
RBS-3654 |
|||||||
|
– Reference E-TFCI |
83 |
RBS-3655 |
|||||||
|
– Reference E-TFCI PO |
16 |
RBS-3656 |
|||||||
|
– Maximum channelisation codes |
2sf2and2sf4 |
RBS-3657 |
|||||||
|
– PLnon-max |
0.84 |
RBS-3658 |
|||||||
|
– Scheduling Information Configuration |
RBS-3659 |
||||||||
|
– Periodicity for Scheduling Info – no grant |
Not present |
RBS-3660 |
|||||||
|
– Periodicity for Scheduling Info – grant |
Not present |
RBS-3661 |
|||||||
|
– Power Offset for Scheduling Info |
0 |
RBS-3662 |
|||||||
|
– 3-Index-Step Threshold |
Not present |
RBS-3663 |
|||||||
|
– 2-Index-Step Threshold |
Not present |
RBS-3664 |
|||||||
|
– Scheduled Transmission configuration |
RBS-3665 |
||||||||
|
– 2ms scheduled transmission grant HARQ process allocation |
Not present |
RBS-3666 |
|||||||
|
– Serving Grant |
Not present |
RBS-3667 |
|||||||
|
-UL 16QAM settings |
Rel-7 |
RBS-3668 |
|||||||
|
-BetaEd gain E-AGCH table selection |
1 |
RBS-3669 |
|||||||
|
E-DCH info |
A19a, A19b |
Rel-7 Rel-7 Rel-7 Rel-7 |
RBS-3670 RBS-3671 RBS-3672 |
||||||
|
TRUE 0 100 ms Not Present Not Present 0 10 3 E-TFCIs 105 12 116 14 127 16 2sf2and2sf4 0.84 Not present Not present 0 Not present Not present Not present Not present 1 |
|||||||||
|
– MAC- e/es reset indicator – E-DPCCH info – E-DPCCH/DPCCH power offset – Happy bit delay condition – E-TFC Boost Info – E-DPDCH power interpolation – E-DPDCH info – E-TFCI table index – E-DCH minimum set E-TFCI – Reference E-TFCIs – Reference E-TFCI – Reference E-TFCI PO – Reference E-TFCI – Reference E-TFCI PO – Reference E-TFCI – Reference E-TFCI PO – Maximum channelisation codes – PLnon-max – Scheduling Information Configuration – Periodicity for Scheduling Info – no grant – Periodicity for Scheduling Info – grant – Power Offset for Scheduling Info – 3-Index-Step Threshold – 2-Index-Step Threshold – Scheduled Transmission configuration – 2ms scheduled transmission grant HARQ process allocation – Serving Grant -UL 16QAM settings -BetaEd gain E-AGCH table selection |
|||||||||
|
E-DCH info |
A24 |
Not Present |
Rel-7 |
RBS-3673 |
|||||
|
, A29 |
Rel-8 |
RBS-3674 |
|||||||
|
Uplink secondary cell info FDD |
, A31, A32 , A33, A34, A35, A36, A37 |
Not Present |
Rel-9 Rel-10 |
RBS-3675 |
|||||
|
Uplink secondary cell info FDD |
A25c |
Rel-9 |
RBS-3676 |
||||||
|
– Secondary serving E-DCH cell info |
RBS-3677 |
||||||||
|
– Primary E-RNTI |
‘1010 1010 1010 1011’ |
RBS-3678 |
|||||||
|
– Secondary E-RNTI |
Not Present |
RBS-3679 |
|||||||
|
– Secondary E-DCH info common |
RBS-3680 |
||||||||
|
– Frequency info |
RBS-3681 |
||||||||
|
– UARFCN uplink (Nu) |
Reference to clause 5.1 Test frequencies |
RBS-3682 |
|||||||
|
– UARFCN downlink (Nd) |
Reference to clause 5.1 Test frequencies |
RBS-3683 |
|||||||
|
– Scrambling code type |
Long |
RBS-3684 |
|||||||
|
– Scrambling code number |
0 |
RBS-3685 |
|||||||
|
– 2ms scheduled transmission grant HARQ process allocation |
Not Present |
RBS-3686 |
|||||||
|
– Serving Grant |
RBS-3687 |
||||||||
|
– Primary/Secondary Grant Selector |
Primary |
RBS-3688 |
|||||||
|
– Minimum reduced E-DPDCH gain factor. |
21/15 |
RBS-3689 |
|||||||
|
– E-DCH minimum set E-TFCI |
1 |
RBS-3690 |
|||||||
|
– DPCCH Power offset for secondary UL frequency |
0 dB |
RBS-3691 |
|||||||
|
– PC Preamble |
0 frame |
RBS-3692 |
|||||||
|
– Downlink information per radio link list on secondary UL frequency |
RBS-3693 |
||||||||
|
– Downlink information for each radio link on secondary UL frequency |
1 |
RBS-3694 |
|||||||
|
– Primary CPICH info |
RBS-3695 |
||||||||
|
– Primary scrambling code |
Ref. to the Default setting in clause 6.1 (FDD) |
RBS-3696 |
|||||||
|
– Cell ID |
Not Present |
RBS-3697 |
|||||||
|
– Downlink F-DPCH info for each RL on secondary UL frequency |
RBS-3698 |
||||||||
|
– Downlink F-DPCH info for each RL |
RBS-3699 |
||||||||
|
– Primary CPICH usage for channel estimate |
RBS-3700 |
||||||||
|
– F-DPCH frame offset |
Set to value Default DPCH Offset Value (as currently stored in SS) mod 38 400 |
RBS-3701 |
|||||||
|
– F-DPCH slot format |
3 if UE supports enhanced F-DPCH, otherwise Not Present |
RBS-3702 |
|||||||
|
– Secondary CPICH info |
Not Present |
RBS-3703 |
|||||||
|
– Secondary scrambling code |
Not Present |
RBS-3704 |
|||||||
|
– Code number |
11 |
RBS-3705 |
|||||||
|
– TPC combination index |
0 |
RBS-3706 |
|||||||
|
– STTD indication |
Not Present |
RBS-3707 |
|||||||
|
– E-AGCH Info |
RBS-3708 |
||||||||
|
– E-AGCH Channelisation Code |
10 |
RBS-3709 |
|||||||
|
– E-HICH Info |
RBS-3710 |
||||||||
|
– Channelisation Code |
4 |
RBS-3711 |
|||||||
|
– Signature Sequence |
1 |
RBS-3712 |
|||||||
|
– E-RGCH Info |
RBS-3713 |
||||||||
|
– Signature Sequence |
0 |
RBS-3714 |
|||||||
|
– RG combination index |
0 |
RBS-3715 |
|||||||
|
CHOICE Mode |
A1, A2, A3, A4, A5, A6, A7, A8, A11 |
FDD |
R99 and Rel-4 only |
RBS-3716 |
|||||
|
– Downlink PDSCH information |
Not Present |
RBS-3717 |
|||||||
|
Downlink HS-PDSCH Information |
A1, A2, A3, A4, A5, A6, A7, A8, A11 |
Not Present |
Rel-5 |
RBS-3718 |
|||||
|
Downlink HS-PDSCH Information |
A9, A10 |
Rel-5 |
RBS-3719 |
||||||
|
, A12, A13, A14, A15, A16 |
Rel-6 |
RBS-3720 |
|||||||
|
, A17, A17d, A18, A19, A19a, A19b, A20, A21, A22, A24 |
Rel-7 |
RBS-3721 |
|||||||
|
, A25, A25b, A29 |
Rel-8 |
RBS-3722 |
|||||||
|
– HS-SCCH Info |
RBS-3723 |
||||||||
|
– CHOICE mode |
FDD |
RBS-3724 |
|||||||
|
– DL Scrambling Code |
Not present |
RBS-3725 |
|||||||
|
– HS-SCCH Channelisation Code Information |
RBS-3726 |
||||||||
|
– HS-SCCH Channelisation Code |
7 |
RBS-3727 |
|||||||
|
– Measurement Feedback Info |
RBS-3728 |
||||||||
|
– CHOICE mode |
FDD |
RBS-3729 |
|||||||
|
– POhsdsch |
6 dB |
RBS-3730 |
|||||||
|
– CQI Feedback cycle, k |
4 ms |
RBS-3731 |
|||||||
|
– CQI repetition factor |
1 |
RBS-3732 |
|||||||
|
– CQI |
5 (corresponds to 0dB in relative power offset) |
RBS-3733 |
|||||||
|
– CHOICE mode |
FDD (no data) |
RBS-3734 |
|||||||
|
– Downlink 64QAM configured |
Not present |
Rel-7 |
RBS-3735 |
||||||
|
– HS-DSCH TB size table |
Not present |
Rel-7 |
RBS-3736 |
||||||
|
Downlink HS-PDSCH Information |
A25a |
Rel-8 |
RBS-3737 |
||||||
|
– HS-SCCH Info |
RBS-3738 |
||||||||
|
– CHOICE mode |
FDD |
RBS-3739 |
|||||||
|
– DL Scrambling Code |
Not present |
RBS-3740 |
|||||||
|
– HS-SCCH Channelisation Code Information |
RBS-3741 |
||||||||
|
– HS-SCCH Channelisation Code |
7 |
RBS-3742 |
|||||||
|
– Measurement Feedback Info |
RBS-3743 |
||||||||
|
– CHOICE mode |
FDD |
RBS-3744 |
|||||||
|
– POhsdsch |
6 dB |
RBS-3745 |
|||||||
|
– CQI Feedback cycle, k |
4 ms |
RBS-3746 |
|||||||
|
– CQI repetition factor |
1 |
RBS-3747 |
|||||||
|
– CQI |
5 (corresponds to 0dB in relative power offset) |
RBS-3748 |
|||||||
|
– CHOICE mode |
FDD (no data) |
RBS-3749 |
|||||||
|
– Downlink 64QAM configured |
Not present |
Rel-7 |
RBS-3750 |
||||||
|
– HS-DSCH TB size table |
Octet Aligned |
Rel-7 |
RBS-3751 |
||||||
|
Downlink HS-PDSCH Information |
A17a |
Rel-7 |
RBS-3752 |
||||||
|
, A28 |
Rel-8 |
RBS-3753 |
|||||||
|
– HS-SCCH Info |
RBS-3754 |
||||||||
|
– CHOICE mode |
FDD |
RBS-3755 |
|||||||
|
– DL Scrambling Code |
Not Present |
RBS-3756 |
|||||||
|
– HS-SCCH Channelisation Code Information |
RBS-3757 |
||||||||
|
– HS-SCCH Channelisation Code |
4 |
RBS-3758 |
|||||||
|
– HS-SCCH Channelisation Code |
5 |
RBS-3759 |
|||||||
|
– Measurement Feedback Info |
RBS-3760 |
||||||||
|
– CHOICE mode |
FDD |
RBS-3761 |
|||||||
|
– POhsdsch |
6 dB |
RBS-3762 |
|||||||
|
– CQI Feedback cycle, k |
4 ms |
RBS-3763 |
|||||||
|
– CQI repetition factor |
1 |
RBS-3764 |
|||||||
|
– CQI |
5 (corresponds to 0dB in relative power offset) |
RBS-3765 |
|||||||
|
– CHOICE mode |
FDD |
RBS-3766 |
|||||||
|
– Downlink 64QAM configured |
TRUE |
Rel-7 |
RBS-3767 |
||||||
|
– HS-DSCH TB size table |
Octet Aligned |
Rel-7 |
RBS-3768 |
||||||
|
Downlink HS-PDSCH Information |
A17b |
Rel-7 |
RBS-3769 |
||||||
|
, A23 |
Rel-7 Rel-8 |
RBS-3770 |
|||||||
|
, A26, A27, A27a, A30 A25c, A41, A42, A43 |
Rel-8 Rel-9, Rel-11 |
RBS-3771 |
|||||||
|
– HS-SCCH Info |
RBS-3772 |
||||||||
|
– CHOICE mode |
FDD |
RBS-3773 |
|||||||
|
– DL Scrambling Code |
Not present |
RBS-3774 |
|||||||
|
– HS-SCCH Channelisation Code Information |
RBS-3775 |
||||||||
|
– HS-SCCH Channelisation Code |
7 |
RBS-3776 |
|||||||
|
– Measurement Feedback Info |
RBS-3777 |
||||||||
|
– CHOICE mode |
FDD |
RBS-3778 |
|||||||
|
– POhsdsch |
6 dB |
RBS-3779 |
|||||||
|
– CQI Feedback cycle, k |
4 ms |
RBS-3780 |
|||||||
|
– CQI repetition factor |
1 |
RBS-3781 |
|||||||
|
– CQI |
5 (corresponds to 0dB in relative power offset) |
RBS-3782 |
|||||||
|
– CHOICE mode |
FDD (no data) |
RBS-3783 |
|||||||
|
– Downlink 64QAM configured |
Not present |
Rel-7 |
RBS-3784 |
||||||
|
– HS-DSCH TB size table |
Octet Aligned |
Rel-7 |
RBS-3785 |
||||||
|
Downlink HS-PDSCH Information |
A17c, A17e, A17f |
Rel-7 |
RBS-3786 |
||||||
|
– HS-SCCH Info |
RBS-3787 |
||||||||
|
– CHOICE mode |
FDD |
RBS-3788 |
|||||||
|
– DL Scrambling Code |
Not Present |
RBS-3789 |
|||||||
|
– HS-SCCH Channelisation Code Information |
RBS-3790 |
||||||||
|
– HS-SCCH Channelisation Code |
6 |
RBS-3791 |
|||||||
|
– HS-SCCH Channelisation Code |
7 |
RBS-3792 |
|||||||
|
– Measurement Feedback Info |
RBS-3793 |
||||||||
|
– CHOICE mode |
FDD |
RBS-3794 |
|||||||
|
– Pohsdsch |
6 dB |
RBS-3795 |
|||||||
|
– CQI Feedback cycle, k |
4 ms |
RBS-3796 |
|||||||
|
– CQI repetition factor |
1 |
RBS-3797 |
|||||||
|
– CQI |
5 (corresponds to 0dB in relative power offset) |
RBS-3798 |
|||||||
|
– CHOICE mode |
FDD |
RBS-3799 |
|||||||
|
– Downlink 64QAM configured |
TRUE |
RBS-3800 |
|||||||
|
– HS-DSCH TB size table |
Octet Aligned |
RBS-3801 |
|||||||
|
Downlink HS-PDSCH Information |
A28a |
Rel-7 |
RBS-3802 |
||||||
|
– HS-SCCH Info |
RBS-3803 |
||||||||
|
– CHOICE mode |
FDD |
RBS-3804 |
|||||||
|
– DL Scrambling Code |
Not Present |
RBS-3805 |
|||||||
|
– HS-SCCH Channelisation Code Information |
RBS-3806 |
||||||||
|
– HS-SCCH Channelisation Code |
4 |
RBS-3807 |
|||||||
|
– HS-SCCH Channelisation Code |
5 |
RBS-3808 |
|||||||
|
– Measurement Feedback Info |
RBS-3809 |
||||||||
|
– CHOICE mode |
FDD |
RBS-3810 |
|||||||
|
– Pohsdsch |
6 dB |
RBS-3811 |
|||||||
|
– CQI Feedback cycle, k |
4 ms |
RBS-3812 |
|||||||
|
– CQI repetition factor |
1 |
RBS-3813 |
|||||||
|
– CQI |
5 (corresponds to 0dB in relative power offset) |
RBS-3814 |
|||||||
|
– CHOICE mode |
FDD |
RBS-3815 |
|||||||
|
– Downlink 64QAM configured |
Not Present |
RBS-3816 |
|||||||
|
– HS-DSCH TB size table |
Not Present |
RBS-3817 |
|||||||
|
Downlink HS-PDSCH Information |
A31 , A34, A36 |
Rel-9 Rel-10 |
RBS-3818 |
||||||
|
– HS-SCCH Info |
RBS-3819 |
||||||||
|
– CHOICE mode |
FDD |
RBS-3820 |
|||||||
|
– DL Scrambling Code |
Not Present |
RBS-3821 |
|||||||
|
– HS-SCCH Channelisation Code Information |
RBS-3822 |
||||||||
|
– HS-SCCH Channelisation Code |
6 |
RBS-3823 |
|||||||
|
– HS-SCCH Channelisation Code |
7 |
RBS-3824 |
|||||||
|
– Measurement Feedback Info |
RBS-3825 |
||||||||
|
– CHOICE mode |
FDD |
RBS-3826 |
|||||||
|
– Pohsdsch |
8 dB |
RBS-3827 |
|||||||
|
– CQI Feedback cycle, k |
8 ms |
RBS-3828 |
|||||||
|
– CQI repetition factor |
1 |
RBS-3829 |
|||||||
|
– CQI |
4 (corresponds to 0dB in relative power offset) |
RBS-3830 |
|||||||
|
– CHOICE mode |
FDD |
RBS-3831 |
|||||||
|
– Downlink 64QAM configured |
Not Present |
RBS-3832 |
|||||||
|
– HS-DSCH TB size table |
Not Present |
RBS-3833 |
|||||||
|
Downlink HS-PDSCH Information |
A32 , A33, A35, A37 A38, A39, A40, A44, A45 |
Rel-9 Rel-10 Rel-11 |
RBS-3834 |
||||||
|
– HS-SCCH Info |
RBS-3835 |
||||||||
|
– CHOICE mode |
FDD |
RBS-3836 |
|||||||
|
– DL Scrambling Code |
Not Present |
RBS-3837 |
|||||||
|
– HS-SCCH Channelisation Code Information |
RBS-3838 |
||||||||
|
– HS-SCCH Channelisation Code |
Refer to clause 5.5.1.3 |
RBS-3839 |
|||||||
|
– Measurement Feedback Info |
RBS-3840 |
||||||||
|
– CHOICE mode |
FDD |
RBS-3841 |
|||||||
|
– Pohsdsch |
8 dB |
RBS-3842 |
|||||||
|
– CQI Feedback cycle, k |
8 ms |
RBS-3843 |
|||||||
|
– CQI repetition factor |
1 |
RBS-3844 |
|||||||
|
– CQI |
4 (corresponds to 0dB in relative power offset) |
RBS-3845 |
|||||||
|
– CHOICE mode |
FDD |
RBS-3846 |
|||||||
|
– Downlink 64QAM configured |
TRUE |
RBS-3847 |
|||||||
|
– HS-DSCH TB size table |
Not present |
RBS-3848 |
|||||||
|
Downlink information common for all radio links |
A1, A2, A3, A11 |
RBS-3865 |
|||||||
|
– Downlink DPCH info common for all RL |
RBS-3866 |
||||||||
|
– Timing indicator |
Maintain |
RBS-3867 |
|||||||
|
– CFN-targetSFN frame offset |
Not Present |
RBS-3868 |
|||||||
|
– Downlink DPCH power control information |
RBS-3869 |
||||||||
|
– DPC mode |
0 (single) |
RBS-3870 |
|||||||
|
– CHOICE mode |
FDD |
RBS-3871 |
|||||||
|
– Power offset PPilot-DPDCH |
0 |
RBS-3872 |
|||||||
|
– DL rate matching restriction information |
Not Present |
RBS-3873 |
|||||||
|
– Spreading factor |
Reference to clause 6.10 Parameter Set |
RBS-3874 |
|||||||
|
– Fixed or Flexible Position |
Reference to clause 6.10 Parameter Set |
RBS-3875 |
|||||||
|
– TFCI existence |
Reference to clause 6.10 Parameter Set |
RBS-3876 |
|||||||
|
– CHOICE SF |
Reference to clause 6.10 Parameter Set |
RBS-3877 |
|||||||
|
– CHOICE mode |
FDD |
RBS-3878 |
|||||||
|
– DPCH compressed mode info |
Not Present |
RBS-3879 |
|||||||
|
– TX Diversity mode |
None |
RBS-3880 |
|||||||
|
– SSDT information |
Not Present |
R99 and Rel-4 only |
RBS-3881 |
||||||
|
– Default DPCH Offset Value |
Not Present |
RBS-3882 |
|||||||
|
Downlink information common for all radio links |
A9 |
Rel-5 |
RBS-3883 |
||||||
|
, A12, A13, A15 |
Rel-6 |
RBS-3884 |
|||||||
|
, A17, A17a, A17d, A17e, , A17f A18. A19, A19a |
Rel-7 |
RBS-3885 |
|||||||
|
, A25a, A25b, A26, A28 |
Rel-8 |
RBS-3886 |
|||||||
|
A35 |
Rel-10 |
RBS-3886a |
|||||||
|
A38, A39, A40, A41, A42, A43, A44, A45 |
Rel-11 |
RBS-3886b |
|||||||
|
– Downlink DPCH info common for all RL |
RBS-3887 |
||||||||
|
– Timing indicator |
Maintain |
RBS-3888 |
|||||||
|
– CFN-targetSFN frame offset |
Not Present |
RBS-3889 |
|||||||
|
– Downlink DPCH power control information |
RBS-3890 |
||||||||
|
– DPC mode |
0 (single) |
RBS-3891 |
|||||||
|
– CHOICE mode |
FDD |
RBS-3892 |
|||||||
|
– Power offset PPilot-DPDCH |
0 |
RBS-3893 |
|||||||
|
– DL rate matching restriction information |
Not Present |
RBS-3894 |
|||||||
|
– Spreading factor |
Reference to clause 6.10 Parameter Set |
RBS-3895 |
|||||||
|
– Fixed or Flexible Position |
Reference to clause 6.10 Parameter Set |
RBS-3896 |
|||||||
|
– TFCI existence |
Reference to clause 6.10 Parameter Set |
RBS-3897 |
|||||||
|
– CHOICE SF |
Reference to clause 6.10 Parameter Set |
RBS-3898 |
|||||||
|
– CHOICE mode |
FDD |
RBS-3899 |
|||||||
|
– DPCH compressed mode info |
Not Present |
RBS-3900 |
|||||||
|
– TX Diversity mode |
None |
RBS-3901 |
|||||||
|
– Default DPCH Offset Value |
Not Present |
RBS-3902 |
|||||||
|
– MAC-hs reset indicator |
Not Present |
RBS-3903 |
|||||||
|
Downlink information common for all radio links |
A4,A7,A8 |
RBS-3904 |
|||||||
|
– Downlink DPCH info common for all RL |
RBS-3905 |
||||||||
|
– Timing indicator |
Initialize |
RBS-3906 |
|||||||
|
– CFN-targetSFN frame offset |
Not Present |
RBS-3907 |
|||||||
|
– Downlink DPCH power control information |
RBS-3908 |
||||||||
|
– DPC mode |
0 (single) |
RBS-3909 |
|||||||
|
– CHOICE mode |
FDD |
RBS-3910 |
|||||||
|
– Power offset PPilot-DPDCH |
0 |
RBS-3911 |
|||||||
|
– DL rate matching restriction information |
Not Present |
RBS-3912 |
|||||||
|
– Spreading factor |
Reference to clause 6.10 Parameter Set |
RBS-3913 |
|||||||
|
– Fixed or Flexible Position |
Reference to clause 6.10 Parameter Set |
RBS-3914 |
|||||||
|
– TFCI existence |
Reference to clause 6.10 Parameter Set |
RBS-3915 |
|||||||
|
– CHOICE SF |
Reference to clause 6.10 Parameter Set |
RBS-3916 |
|||||||
|
– CHOICE mode |
FDD |
RBS-3917 |
|||||||
|
– DPCH compressed mode info |
Not Present |
RBS-3918 |
|||||||
|
– TX Diversity mode |
None |
RBS-3919 |
|||||||
|
– SSDT information |
Not Present |
R99 and Rel-4 only |
RBS-3920 |
||||||
|
– Default DPCH Offset Value |
Arbitrary set to value 0..306688 by step of 512 |
RBS-3921 |
|||||||
|
Downlink information common for all radio links |
A10 |
Rel-5 |
RBS-3922 |
||||||
|
– Downlink DPCH info common for all RL |
RBS-3923 |
||||||||
|
– Timing indicator |
Initialize |
RBS-3924 |
|||||||
|
– CFN-targetSFN frame offset |
Not Present |
RBS-3925 |
|||||||
|
– Downlink DPCH power control information |
|
RBS-3926 |
|||||||
|
– DPC mode |
0 (single) |
RBS-3927 |
|||||||
|
– CHOICE mode |
FDD |
RBS-3928 |
|||||||
|
– Power offset PPilot-DPDCH |
0 |
RBS-3929 |
|||||||
|
– DL rate matching restriction information |
Not Present |
RBS-3930 |
|||||||
|
– Spreading factor |
Reference to clause 6.10 Parameter Set |
RBS-3931 |
|||||||
|
– Fixed or Flexible Position |
Reference to clause 6.10 Parameter Set |
RBS-3932 |
|||||||
|
– TFCI existence |
Reference to clause 6.10 Parameter Set |
RBS-3933 |
|||||||
|
– CHOICE SF |
Reference to clause 6.10 Parameter Set |
RBS-3934 |
|||||||
|
– CHOICE mode |
FDD |
RBS-3935 |
|||||||
|
– DPCH compressed mode info |
Not Present |
RBS-3936 |
|||||||
|
– TX Diversity mode |
None |
RBS-3937 |
|||||||
|
– Default DPCH Offset Value |
Arbitrary set to value 0..306688 by step of 512 |
RBS-3938 |
|||||||
|
– MAC-hs reset indicator |
Not Present |
RBS-3939 |
|||||||
|
Downlink information common for all radio links |
A14, A16 |
Rel-6 |
RBS-3940 |
||||||
|
, A17b, A17c, A19b, A20, A21, A22 |
Rel-7 |
RBS-3941 |
|||||||
|
, A23, A28a |
Rel-7 Rel-8 |
RBS-3942 |
|||||||
|
, A25, A27, A27a A25c, A31, A32 |
Rel-8 Rel-9 |
RBS-3943 |
|||||||
|
A33, A34, A36, A37 |
Rel-10 |
RBS-3943a |
|||||||
|
– Downlink F-DPCH info common for all RL |
RBS-3944 |
||||||||
|
– Timing Indication |
Maintain |
RBS-3945 |
|||||||
|
– Timing maintained Synchronization indicator |
FALSE |
RBS-3946 |
|||||||
|
– Downlink F-DPCH power control information |
RBS-3947 |
||||||||
|
– DPC mode |
0 (single) |
RBS-3948 |
|||||||
|
– TPC command error rate target |
0.04 |
RBS-3949 |
|||||||
|
– CHOICE mode |
FDD |
RBS-3950 |
|||||||
|
– DPCH compressed mode info |
Not Present |
RBS-3951 |
|||||||
|
– TX Diversity mode |
None |
RBS-3952 |
|||||||
|
– Default DPCH Offset Value |
Not Present |
RBS-3953 |
|||||||
|
– MAC-hs reset indicator |
Not Present |
RBS-3954 |
|||||||
|
Downlink information common for all radio links |
A5,A6 |
Not Present |
RBS-3955 |
||||||
|
, A24 |
Not Present |
Rel-7 |
RBS-3956 |
||||||
|
, A29 |
RBS-3957 |
||||||||
|
Downlink information common for all radio links – Downlink F-DPCH info common for all RL – Timing Indication – Downlink F-DPCH power control Information – DPC mode – TPC command error rate target – CHOICE mode – DPCH compressed mode info – TX Diversity mode – Default DPCH Offset Value – MAC-hs reset indicator |
A30 |
Initialise 0 (single) 0.04 FDD Not Present None Arbitrary set to value 0..306688 by step of 512 TRUE |
Rel-8 |
RBS-3957a |
|||||
|
Downlink information for each radio link list |
A1, A2, A3, A4, A7, A8, A11 |
RBS-3958 |
|||||||
|
– Downlink information for each radio link |
RBS-3959 |
||||||||
|
– Choice mode |
FDD |
RBS-3960 |
|||||||
|
– Primary CPICH info |
RBS-3961 |
||||||||
|
– Primary scrambling code |
Ref. to the Default setting in clause 6.1 (FDD) |
RBS-3962 |
|||||||
|
– PDSCH with SHO DCH info |
Not Present |
R99 and Rel-4 only |
RBS-3963 |
||||||
|
– PDSCH code mapping |
Not Present |
R99 and Rel-4 only |
RBS-3964 |
||||||
|
– Serving HS-DSCH radio link indicator |
FALSE |
Rel-5 |
RBS-3965 |
||||||
|
– Downlink DPCH info for each RL |
RBS-3966 |
||||||||
|
– Primary CPICH usage for channel estimation |
Primary CPICH may be used |
RBS-3967 |
|||||||
|
– DPCH frame offset |
Set to value Default DPCH Offset Value (as currently stored in SS) mod 38 400 |
RBS-3968 |
|||||||
|
– Secondary CPICH info |
Not Present |
RBS-3969 |
|||||||
|
– DL channelisation code |
|
RBS-3970 |
|||||||
|
– Secondary scrambling code |
1 |
RBS-3971 |
|||||||
|
– Spreading factor |
Reference to clause 6.10 Parameter Set |
RBS-3972 |
|||||||
|
– Code number |
0 |
RBS-3973 |
|||||||
|
– Scrambling code change |
Set to value Default1: No code change (if the UE has a compressed mode pattern sequence configured in variable TGPS_IDENTITY or included in the message including IE "Downlink DPCH info for each RL", which is using compressed mode method "SF/2") Set to value Default2: OMIT (otherwise) |
RBS-3974 |
|||||||
|
– TPC combination index |
0 |
RBS-3975 |
|||||||
|
– SSDT Cell Identity |
Not Present |
R99 and Rel-4 only |
RBS-3976 |
||||||
|
– Closed loop timing adjustment mode |
Not Present |
|
RBS-3977 |
||||||
|
– SCCPCH information for FACH |
Not Present |
R99 and Rel-4 only |
RBS-3978 |
||||||
|
Downlink information for each radio link list |
A5 |
RBS-3979 |
|||||||
|
– Downlink information for each radio link |
RBS-3980 |
||||||||
|
– Choice mode |
FDD |
RBS-3981 |
|||||||
|
– Primary CPICH info |
|
RBS-3982 |
|||||||
|
– Primary scrambling code |
Ref. to the Default setting in clause 6.1 (FDD) |
RBS-3983 |
|||||||
|
– PDSCH with SHO DCH info |
Not Present |
R99 and Rel-4 only |
RBS-3984 |
||||||
|
– PDSCH code mapping |
Not Present |
R99 and Rel-4 only |
RBS-3985 |
||||||
|
– Serving HS-DSCH radio link indicator |
FALSE |
Rel-5 |
RBS-3986 |
||||||
|
– Downlink DPCH info for each RL |
Not present |
RBS-3987 |
|||||||
|
– SCCPCH information for FACH |
Not Present |
R99 and Rel-4 only |
RBS-3988 |
||||||
|
Downlink information for each radio link list |
A9, A10 |
Rel-5 |
RBS-3989 |
||||||
|
, A17, A18 |
Rel-7 |
RBS-3990 |
|||||||
|
– Downlink information for each radio link |
RBS-3991 |
||||||||
|
– Choice mode |
FDD |
RBS-3992 |
|||||||
|
– Primary CPICH info |
RBS-3993 |
||||||||
|
– Primary scrambling code |
Ref. to the Default setting in clause 6.1 (FDD) |
RBS-3994 |
|||||||
|
– PDSCH with SHO DCH info |
Not Present |
R99 and Rel-4 only |
RBS-3995 |
||||||
|
– PDSCH code mapping |
Not Present |
R99 and Rel-4 only |
RBS-3996 |
||||||
|
– Serving HS-DSCH radio link indicator |
TRUE |
RBS-3997 |
|||||||
|
– Serving E-DCH radio link indicator |
FALSE |
Rel-6 |
RBS-3998 |
||||||
|
– Downlink DPCH info for each RL |
RBS-3999 |
||||||||
|
– Primary CPICH usage for channel estimation |
Primary CPICH may be used |
RBS-4000 |
|||||||
|
– DPCH frame offset |
Set to value Default DPCH Offset Value (as currently stored in SS) mod 38 400 |
RBS-4001 |
|||||||
|
– Secondary CPICH info |
Not Present |
RBS-4002 |
|||||||
|
– DL channelisation code |
|
RBS-4003 |
|||||||
|
– Secondary scrambling code |
1 |
RBS-4004 |
|||||||
|
– Spreading factor |
Reference to clause 6.10 Parameter Set |
RBS-4005 |
|||||||
|
– Code number |
0 |
RBS-4006 |
|||||||
|
– Scrambling code change |
Set to value Default1: No code change (if the UE has a compressed mode pattern sequence configured in variable TGPS_IDENTITY or included in the message including IE "Downlink DPCH info for each RL", which is using compressed mode method "SF/2") Set to value Default2: OMIT (otherwise) |
RBS-4007 |
|||||||
|
– TPC combination index |
0 |
RBS-4008 |
|||||||
|
– SSDT Cell Identity |
Not Present |
R99 and Rel-4 only |
RBS-4009 |
||||||
|
– Closed loop timing adjustment mode |
Not Present |
RBS-4010 |
|||||||
|
– E-AGCH Info |
Not Present |
Rel-6 |
RBS-4011 |
||||||
|
– CHOICE E-HICH Information |
Not Present |
Rel-6 |
RBS-4012 |
||||||
|
– CHOICE E-RGCH Information |
Not Present |
Rel-6 |
RBS-4013 |
||||||
|
– SCCPCH information for FACH |
Not Present |
R99 and Rel-4 only |
RBS-4014 |
||||||
|
Downlink information for each radio link list |
A17a, A17d, A17e, |
Rel-7 |
RBS-4015 |
||||||
|
, A25a, A28 |
Rel-8 |
RBS-4016 |
|||||||
|
– Downlink information for each radio link |
RBS-4017 |
||||||||
|
– Choice mode |
FDD |
RBS-4018 |
|||||||
|
– Primary CPICH info |
RBS-4019 |
||||||||
|
– Primary scrambling code |
Ref. to the Default setting in clause 6.1 (FDD) |
RBS-4020 |
|||||||
|
– Serving HS-DSCH radio link indicator |
TRUE |
RBS-4021 |
|||||||
|
– Serving E-DCH radio link indicator |
FALSE |
Rel-6 |
RBS-4022 |
||||||
|
– Downlink DPCH info for each RL |
RBS-4023 |
||||||||
|
– Primary CPICH usage for channel estimation |
Primary CPICH may be used |
RBS-4024 |
|||||||
|
– DPCH frame offset |
Set to value Default DPCH Offset Value (as currently stored in SS) mod 38 400 |
RBS-4025 |
|||||||
|
– Secondary CPICH info |
Not Present |
RBS-4026 |
|||||||
|
– DL channelisation code |
RBS-4027 |
||||||||
|
– Secondary scrambling code |
Not Present |
RBS-4028 |
|||||||
|
– Spreading factor |
Reference to clause 6.10 Parameter Set |
RBS-4029 |
|||||||
|
– Code number |
13 |
RBS-4030 |
|||||||
|
– Scrambling code change |
Not Present |
RBS-4031 |
|||||||
|
– TPC combination index |
0 |
RBS-4032 |
|||||||
|
– Closed loop timing adjustment mode |
Not Present |
RBS-4033 |
|||||||
|
– E-AGCH Info |
Not Present |
Rel-6 |
RBS-4034 |
||||||
|
– CHOICE E-HICH Information |
Not Present |
Rel-6 |
RBS-4035 |
||||||
|
– CHOICE E-RGCH Information |
Not Present |
Rel-6 |
RBS-4036 |
||||||
|
Downlink information for each radio link list |
A25b |
Rel-8 |
RBS-4037 |
||||||
|
– Downlink information for each radio link |
RBS-4038 |
||||||||
|
– Choice mode |
FDD |
RBS-4039 |
|||||||
|
– Primary CPICH info |
RBS-4040 |
||||||||
|
– Primary scrambling code |
Ref. to the Default setting in clause 6.1 (FDD) |
RBS-4041 |
|||||||
|
– Serving HS-DSCH radio link indicator |
TRUE |
RBS-4042 |
|||||||
|
– Serving E-DCH radio link indicator |
TRUE |
Rel-6 |
RBS-4043 |
||||||
|
– Downlink DPCH info for each RL |
RBS-4044 |
||||||||
|
– Primary CPICH usage for channel estimation |
Primary CPICH may be used |
RBS-4045 |
|||||||
|
– DPCH frame offset |
Set to value Default DPCH Offset Value (as currently stored in SS) mod 38 400 |
RBS-4046 |
|||||||
|
– Secondary CPICH info |
Not Present |
RBS-4047 |
|||||||
|
– DL channelisation code |
RBS-4048 |
||||||||
|
– Secondary scrambling code |
Not Present |
RBS-4049 |
|||||||
|
– Spreading factor |
Reference to clause 6.10 Parameter Set |
RBS-4050 |
|||||||
|
– Code number |
13 |
RBS-4051 |
|||||||
|
– Scrambling code change |
Not Present |
RBS-4052 |
|||||||
|
– TPC combination index |
0 |
RBS-4053 |
|||||||
|
– Closed loop timing adjustment mode |
Not Present |
RBS-4054 |
|||||||
|
– E-AGCH Info |
Rel-6 |
RBS-4055 |
|||||||
|
– E-AGCH Channelisation Code |
10 |
RBS-4056 |
|||||||
|
– CHOICE E-HICH Information |
Rel-6 |
RBS-4057 |
|||||||
|
– Channelisation code |
4 |
RBS-4058 |
|||||||
|
– Signature sequence |
1 |
RBS-4059 |
|||||||
|
– CHOICE E-RGCH Information |
RBS-4060 |
||||||||
|
– E-RGCH Information |
RBS-4061 |
||||||||
|
– Signature Sequence |
0 |
RBS-4062 |
|||||||
|
– RG combination index |
0 |
RBS-4063 |
|||||||
|
Downlink information for each radio link list |
A12, A13, A15, A17f |
Rel-6 |
RBS-4064 |
||||||
|
, A19, A19a |
Rel-7 |
RBS-4065 |
|||||||
|
, A26 , A35 A38, A39, A40, A41, A42, A43, A44, A45 |
Rel-8 Rel-10 Rel-11 |
RBS-4066 |
|||||||
|
– Downlink information for each radio link |
RBS-4067 |
||||||||
|
– Choice mode |
FDD |
RBS-4068 |
|||||||
|
– Primary CPICH info |
RBS-4069 |
||||||||
|
– Primary scrambling code |
Ref. to the Default setting in clause 6.1 (FDD) |
RBS-4070 |
|||||||
|
– Serving HS-DSCH radio link indicator |
TRUE |
RBS-4071 |
|||||||
|
– Serving E-DCH radio link indicator |
TRUE |
RBS-4072 |
|||||||
|
– Downlink DPCH info for each RL |
RBS-4073 |
||||||||
|
– Primary CPICH usage for channel estimation |
Primary CPICH may be used |
RBS-4074 |
|||||||
|
– DPCH frame offset |
Set to value Default DPCH Offset Value (as currently stored in SS) mod 38 400 |
RBS-4075 |
|||||||
|
– Secondary CPICH info |
Not Present |
RBS-4076 |
|||||||
|
– DL channelisation code |
RBS-4077 |
||||||||
|
– Secondary scrambling code |
1 |
RBS-4078 |
|||||||
|
– Spreading factor |
Reference to clause 6.10 Parameter Set |
RBS-4079 |
|||||||
|
– Code number |
0 |
RBS-4080 |
|||||||
|
– Scrambling code change |
Set to value: No code change (if the UE has a compressed mode pattern sequence configured in variable TGPS_IDENTITY or included in the message including IE "Downlink DPCH info for each RL", which is using compressed mode method "SF/2") Set to value: OMIT (otherwise) |
Default1 Default2 |
RBS-4081 |
||||||
|
– TPC combination index |
0 |
RBS-4082 |
|||||||
|
– Closed loop timing adjustment mode |
Not Present |
RBS-4083 |
|||||||
|
– E-AGCH Info |
RBS-4084 |
||||||||
|
– E-AGCH Channelisation Code |
10 |
RBS-4085 |
|||||||
|
– CHOICE E-HICH Information |
RBS-4086 |
||||||||
|
– E-HICH Information |
RBS-4087 |
||||||||
|
– Channelisation code |
4 |
RBS-4088 |
|||||||
|
– Signature sequence |
1 |
RBS-4089 |
|||||||
|
– CHOICE E-RGCH Information |
RBS-4090 |
||||||||
|
– E-RGCH Information |
RBS-4091 |
||||||||
|
– Signature Sequence |
0 |
RBS-4092 |
|||||||
|
– RG combination index |
0 |
RBS-4093 |
|||||||
|
Downlink information for each radio link list |
A14, A16 , A19b |
Rel-6 Rel-7 |
RBS-4094 |
||||||
|
– Downlink information for each radio link |
RBS-4095 |
||||||||
|
– Choice mode |
FDD |
RBS-4096 |
|||||||
|
– Primary CPICH info |
RBS-4097 |
||||||||
|
– Primary scrambling code |
Ref. to the Default setting in clause 6.1 (FDD) |
RBS-4098 |
|||||||
|
– Serving HS-DSCH radio link indicator |
TRUE |
RBS-4099 |
|||||||
|
– Serving E-DCH radio link indicator |
TRUE |
RBS-4100 |
|||||||
|
– Downlink DPCH info for each RL |
Not Present |
RBS-4101 |
|||||||
|
– Downlink F-DPCH info for each RL |
RBS-4102 |
||||||||
|
– Primary CPICH usage for channel estimation |
Primary CPICH may be used |
RBS-4103 |
|||||||
|
– F-DPCH frame offset |
Set to value Default DPCH Offset Value (as currently stored in SS) mod 38 400 |
RBS-4104 |
|||||||
|
– F-DPCH slot format |
3 if UE supports enhanced F-DPCH, otherwise Not Present |
Rel-7 |
RBS-4105 |
||||||
|
– Secondary CPICH info |
Not Present |
RBS-4106 |
|||||||
|
– Secondary scrambling code |
Not Present |
RBS-4107 |
|||||||
|
– Code number |
12 |
RBS-4108 |
|||||||
|
– TPC combination index |
0 |
RBS-4109 |
|||||||
|
– E-AGCH Info |
RBS-4110 |
||||||||
|
– E-AGCH Channelisation Code |
10 |
RBS-4111 |
|||||||
|
– CHOICE E-HICH Information |
RBS-4112 |
||||||||
|
– E-HICH Information |
RBS-4113 |
||||||||
|
– Channelisation code |
4 |
RBS-4114 |
|||||||
|
– Signature sequence |
1 |
RBS-4115 |
|||||||
|
– CHOICE E-RGCH Information |
Not Present |
RBS-4116 |
|||||||
|
Downlink information for each radio link list |
A17b, A17c, A28a A25c |
Rel-7 Rel-9 |
RBS-4117 |
||||||
|
– Downlink information for each radio link |
RBS-4118 |
||||||||
|
– Choice mode |
FDD |
RBS-4119 |
|||||||
|
– Primary CPICH info |
RBS-4120 |
||||||||
|
– Primary scrambling code |
Ref. to the Default setting in clause 6.1 (FDD) |
RBS-4121 |
|||||||
|
– Serving HS-DSCH radio link indicator |
TRUE |
RBS-4122 |
|||||||
|
– Serving E-DCH radio link indicator |
TRUE |
RBS-4123 |
|||||||
|
– Downlink DPCH info for each RL |
Not Present |
RBS-4124 |
|||||||
|
– Downlink F-DPCH info for each RL |
RBS-4125 |
||||||||
|
– Primary CPICH usage for channel estimation |
Primary CPICH may be used |
RBS-4126 |
|||||||
|
– F-DPCH frame offset |
Set to value Default DPCH Offset Value (as currently stored in SS) mod 38 400 |
RBS-4127 |
|||||||
|
– F-DPCH slot format |
3 if UE supports enhanced F-DPCH, otherwise Not Present |
RBS-4128 |
|||||||
|
– Secondary CPICH info |
Not Present |
RBS-4129 |
|||||||
|
– Secondary scrambling code |
Not Present |
RBS-4130 |
|||||||
|
– Code number |
11 |
RBS-4131 |
|||||||
|
– TPC combination index |
0 |
RBS-4132 |
|||||||
|
– E-AGCH Info |
RBS-4133 |
||||||||
|
– E-AGCH Channelisation Code |
10 |
RBS-4134 |
|||||||
|
– CHOICE E-HICH Information |
RBS-4135 |
||||||||
|
– E-HICH Information |
RBS-4136 |
||||||||
|
– Channelisation code |
4 |
RBS-4137 |
|||||||
|
– Signature sequence |
1 |
RBS-4138 |
|||||||
|
– CHOICE E-RGCH Information |
Not Present |
RBS-4139 |
|||||||
|
RBS-4140 |
|||||||||
|
Downlink information for each radio link list |
A30 |
Rel-8 |
RBS-4141 |
||||||
|
– Downlink information for each radio link |
RBS-4142 |
||||||||
|
– Choice mode |
FDD |
RBS-4143 |
|||||||
|
– Primary CPICH info |
RBS-4144 |
||||||||
|
– Primary scrambling code |
Ref. to the Default setting in clause 6.1 (FDD) |
RBS-4145 |
|||||||
|
– Serving HS-DSCH radio link indicator |
TRUE |
RBS-4146 |
|||||||
|
– Serving E-DCH radio link indicator |
TRUE |
RBS-4147 |
|||||||
|
– Downlink DPCH info for each RL |
Not Present |
RBS-4148 |
|||||||
|
– Downlink F-DPCH info for each RL |
RBS-4149 |
||||||||
|
– Primary CPICH usage for channel estimation |
Primary CPICH may be used |
RBS-4150 |
|||||||
|
– F-DPCH frame offset |
Set to value Default DPCH Offset Value (as currently stored in SS) mod 38 400 |
RBS-4151 |
|||||||
|
– F-DPCH slot format |
3 if UE supports enhanced F-DPCH, otherwise Not Present |
RBS-4152 |
|||||||
|
– Secondary CPICH info |
Not Present |
RBS-4153 |
|||||||
|
– Secondary scrambling code |
Not Present |
RBS-4154 |
|||||||
|
– Code number |
12 |
RBS-4155 |
|||||||
|
– TPC combination index |
0 |
RBS-4156 |
|||||||
|
– E-AGCH Info |
RBS-4157 |
||||||||
|
– E-AGCH Channelisation Code |
11 |
RBS-4158 |
|||||||
|
– CHOICE E-HICH Information |
RBS-4159 |
||||||||
|
– E-HICH Information |
RBS-4160 |
||||||||
|
– Channelisation code |
4 |
RBS-4161 |
|||||||
|
– Signature sequence |
10 |
RBS-4162 |
|||||||
|
– CHOICE E-RGCH Information |
Not Present |
RBS-4163 |
|||||||
|
Downlink information for each radio link list |
A20, A21, |
Rel-7 |
RBS-4164 |
||||||
|
, A23 |
Rel-7 Rel-8 |
RBS-4165 |
|||||||
|
, A25 |
Rel-8 |
RBS-4166 |
|||||||
|
, A27, A27a |
Rel-8 |
RBS-4167 |
|||||||
|
, A31 , A34, A36 |
Rel-9 Rel-10 |
RBS-4168 |
|||||||
|
– Downlink information for each radio link |
RBS-4169 |
||||||||
|
– Choice mode |
FDD |
RBS-4170 |
|||||||
|
– Primary CPICH info |
RBS-4171 |
||||||||
|
– Primary scrambling code |
Ref. to the Default setting in clause 6.1 (FDD) |
RBS-4172 |
|||||||
|
– Serving HS-DSCH radio link indicator |
TRUE |
RBS-4173 |
|||||||
|
– Serving E-DCH radio link indicator |
TRUE |
RBS-4174 |
|||||||
|
– Downlink DPCH info for each RL |
Not Present |
RBS-4175 |
|||||||
|
– Downlink F-DPCH info for each RL |
RBS-4176 |
||||||||
|
– Primary CPICH usage for channel estimation |
Primary CPICH may be used |
RBS-4177 |
|||||||
|
– F-DPCH frame offset |
Set to value Default DPCH Offset Value (as currently stored in SS) mod 38 400 |
RBS-4178 |
|||||||
|
– F-DPCH slot format |
3 if UE supports enhanced F-DPCH, otherwise Not Present |
Rel-7 |
RBS-4179 |
||||||
|
– Secondary CPICH info |
Not Present |
RBS-4180 |
|||||||
|
– Secondary scrambling code |
Not Present |
RBS-4181 |
|||||||
|
– Code number |
12 |
RBS-4182 |
|||||||
|
– TPC combination index |
0 |
RBS-4183 |
|||||||
|
– E-AGCH Info |
RBS-4184 |
||||||||
|
– E-AGCH Channelisation Code |
10 |
RBS-4185 |
|||||||
|
– CHOICE E-HICH Information |
RBS-4186 |
||||||||
|
– E-HICH Information |
RBS-4187 |
||||||||
|
– Channelisation code |
4 |
RBS-4188 |
|||||||
|
– Signature sequence |
1 |
RBS-4189 |
|||||||
|
– CHOICE E-RGCH Information |
RBS-4190 |
||||||||
|
– E-RGCH Information |
RBS-4191 |
||||||||
|
– Signature Sequence |
0 |
RBS-4192 |
|||||||
|
– RG combination index |
0 |
RBS-4193 |
|||||||
|
Downlink information for each radio link list |
A22 |
Rel-7 |
RBS-4194 |
||||||
|
– Downlink information for each radio link |
RBS-4195 |
||||||||
|
– Choice mode |
FDD |
RBS-4196 |
|||||||
|
– Primary CPICH info |
RBS-4197 |
||||||||
|
– Primary scrambling code |
Ref. to the Default setting in clause 6.1 (FDD) |
RBS-4198 |
|||||||
|
– Serving HS-DSCH radio link indicator |
TRUE |
RBS-4199 |
|||||||
|
– Serving E-DCH radio link indicator |
TRUE |
RBS-4200 |
|||||||
|
– Downlink DPCH info for each RL |
Not Present |
RBS-4201 |
|||||||
|
– Downlink F-DPCH info for each RL |
RBS-4202 |
||||||||
|
– Primary CPICH usage for channel estimation |
Primary CPICH may be used |
RBS-4203 |
|||||||
|
– F-DPCH frame offset |
Set to value Default DPCH Offset Value (as currently stored in SS) mod 38 400 |
RBS-4204 |
|||||||
|
– F-DPCH slot format |
3 if UE supports enhanced F-DPCH, otherwise Not Present |
Rel-7 |
RBS-4205 |
||||||
|
– Secondary CPICH info |
Not Present |
RBS-4206 |
|||||||
|
– Secondary scrambling code |
Not Present |
RBS-4207 |
|||||||
|
– Code number |
12 |
RBS-4208 |
|||||||
|
– TPC combination index |
0 |
RBS-4209 |
|||||||
|
– E-AGCH Info |
RBS-4210 |
||||||||
|
– E-AGCH Channelisation Code |
10 |
RBS-4211 |
|||||||
|
– CHOICE E-HICH Information |
RBS-4212 |
||||||||
|
– E-HICH Information |
RBS-4213 |
||||||||
|
– Channelisation code |
4 |
RBS-4214 |
|||||||
|
– Signature sequence |
1 |
RBS-4215 |
|||||||
|
– CHOICE E-RGCH Information |
RBS-4216 |
||||||||
|
– E-RGCH Information |
Not present |
RBS-4217 |
|||||||
|
– Downlink information for each radio link |
A32, A33, A37 |
Rel-10 |
RBS-4218 |
||||||
|
– Choice mode |
FDD |
RBS-4219 |
|||||||
|
– Primary CPICH info |
RBS-4220 |
||||||||
|
– Primary scrambling code |
Ref. to the Default setting in clause 6.1 (FDD) |
RBS-4221 |
|||||||
|
– Serving HS-DSCH radio link indicator |
TRUE |
RBS-4222 |
|||||||
|
– Serving E-DCH radio link indicator |
TRUE |
RBS-4223 |
|||||||
|
– Downlink DPCH info for each RL |
Not Present |
RBS-4224 |
|||||||
|
– Downlink F-DPCH info for each RL |
RBS-4225 |
||||||||
|
– Primary CPICH usage for channel estimation |
Primary CPICH may be used |
RBS-4226 |
|||||||
|
– F-DPCH frame offset |
Set to value Default DPCH Offset Value (as currently stored in SS) mod 38 400 |
RBS-4227 |
|||||||
|
– F-DPCH slot format |
3 if UE supports enhanced F-DPCH, otherwise Not Present |
Rel-7 |
RBS-4228 |
||||||
|
– Secondary CPICH info |
Not Present |
RBS-4229 |
|||||||
|
– Secondary scrambling code |
Not Present |
RBS-4230 |
|||||||
|
– Code number |
11 |
RBS-4231 |
|||||||
|
– TPC combination index |
0 |
RBS-4232 |
|||||||
|
– E-AGCH Info |
RBS-4233 |
||||||||
|
– E-AGCH Channelisation Code |
10 |
RBS-4234 |
|||||||
|
– CHOICE E-HICH Information |
RBS-4235 |
||||||||
|
– E-HICH Information |
RBS-4236 |
||||||||
|
– Channelisation code |
4 |
RBS-4237 |
|||||||
|
– Signature sequence |
1 |
RBS-4238 |
|||||||
|
– CHOICE E-RGCH Information |
RBS-4239 |
||||||||
|
– E-RGCH Information |
RBS-4240 |
||||||||
|
– Signature Sequence |
0 |
RBS-4241 |
|||||||
|
– RG combination index |
0 |
RBS-4242 |
|||||||
|
Downlink information for each radio link list |
A6, A24 |
Not Present |
RBS-4243 |
||||||
|
A29 |
RBS-4244 |
||||||||
|
Downlink secondary cell info FDD |
A25a A25c , A36 |
Rel-8 Rel-9 Rel-10 |
RBS-4245 |
||||||
|
– CHOICE Configuration info |
New configuration |
RBS-4246 |
|||||||
|
– New H-RNTI |
‘1010 1010 1010 1010’ |
RBS-4247 |
|||||||
|
– Downlink 64QAM configured |
Not Present |
RBS-4248 |
|||||||
|
– HS-DSCH TB size table |
Octet Aligned |
RBS-4249 |
|||||||
|
– Primary CPICH info |
RBS-4250 |
||||||||
|
– Primary scrambling code |
Ref. to the Default setting in clause 6.1 (FDD) |
RBS-4251 |
|||||||
|
– DL Scrambling Code |
Not Present |
RBS-4252 |
|||||||
|
– HS-SCCH Channelisation Code Information |
RBS-4253 |
||||||||
|
– HS-SCCH Channelisation Code |
7 |
RBS-4254 |
|||||||
|
– Measurement Power Offset |
6 dB |
RBS-4255 |
|||||||
|
– UARFCN downlink (Nd) |
Reference to clause 5.1 Test frequencies |
RBS-4256 |
|||||||
|
– Different Tx diversity mode configuration from serving HS-DSCH cell |
Not Present |
Rel-8 |
RBS-4257 |
||||||
|
-Secondary cell MIMO parameters |
Not Present |
Rel-9 |
RBS-4258 |
||||||
|
Downlink secondary cell info FDD |
A25, A25b |
Rel-8 |
RBS-4259 |
||||||
|
RBS-4260 |
|||||||||
|
– CHOICE Configuration info |
New configuration |
RBS-4261 |
|||||||
|
– New H-RNTI |
‘1010 1010 1010 1010’ |
RBS-4262 |
|||||||
|
– Downlink 64QAM configured |
Not Present |
RBS-4263 |
|||||||
|
– HS-DSCH TB size table |
Not Present |
RBS-4264 |
|||||||
|
– Primary CPICH info |
RBS-4265 |
||||||||
|
– Primary scrambling code |
Ref. to the Default setting in clause 6.1 (FDD) |
RBS-4266 |
|||||||
|
– DL Scrambling Code |
Not Present |
RBS-4267 |
|||||||
|
– HS-SCCH Channelisation Code Information |
RBS-4268 |
||||||||
|
– HS-SCCH Channelisation Code |
7 |
RBS-4269 |
|||||||
|
– Measurement Power Offset |
6 dB |
RBS-4270 |
|||||||
|
– UARFCN downlink (Nd) |
Reference to clause 5.1 Test frequencies |
RBS-4271 |
|||||||
|
– Different Tx diversity mode configuration from serving HS-DSCH cell |
Not Present |
Rel-8 |
RBS-4272 |
||||||
|
-Secondary cell MIMO parameters |
Not Present |
Rel-9 |
RBS-4273 |
||||||
|
Downlink secondary cell info FDD |
A31 |
Rel-9 |
RBS-4274 |
||||||
|
, A34 |
Rel-10 |
RBS-4275 |
|||||||
|
– CHOICE Configuration info |
New configuration |
RBS-4276 |
|||||||
|
– New H-RNTI |
‘1010 1010 1010 1010’ |
RBS-4277 |
|||||||
|
– Downlink 64QAM configured |
Not Present |
RBS-4278 |
|||||||
|
– HS-DSCH TB size table |
Not Present |
RBS-4279 |
|||||||
|
– Primary CPICH info |
RBS-4280 |
||||||||
|
– Primary scrambling code |
Ref. to the Default setting in clause 6.1 (FDD) |
RBS-4281 |
|||||||
|
– DL Scrambling Code |
Not Present |
RBS-4282 |
|||||||
|
– HS-SCCH Channelisation Code Information |
RBS-4283 |
||||||||
|
– HS-SCCH Channelisation Code |
7 |
RBS-4284 |
|||||||
|
– Measurement Power Offset |
6 dB |
RBS-4285 |
|||||||
|
– UARFCN downlink (Nd) |
Reference to clause 5.1 Test frequencies |
RBS-4286 |
|||||||
|
– Different Tx diversity mode configuration from serving HS-DSCH cell |
Not Present |
Rel-8 |
RBS-4287 |
||||||
|
-Secondary cell MIMO parameters |
Rel-9 |
RBS-4288 |
|||||||
|
– CHOICE Configuration info |
RBS-4289 |
||||||||
|
– Continue |
RBS-4290 |
||||||||
|
– New configuration |
RBS-4291 |
||||||||
|
– MIMO N_cqi_typeA/M_cqi ratio |
1/1 |
RBS-4292 |
|||||||
|
– MIMO pilot configuration |
RBS-4293 |
||||||||
|
-CHOICE Second CPICH pattern |
RBS-4294 |
||||||||
|
-Antenna2 P-CPICH |
No data |
RBS-4295 |
|||||||
|
-Antenna1 S-CPICH |
RBS-4296 |
||||||||
|
-Channelisation code |
13 |
RBS-4297 |
|||||||
|
-Power Offset for S-CPICH for MIMO |
0 |
RBS-4298 |
|||||||
|
Downlink secondary cell info FDD |
A32 , A33 |
Rel-9 Rel-10 |
RBS-4299 |
||||||
|
– CHOICE Configuration info |
New configuration |
RBS-4300 |
|||||||
|
– New H-RNTI |
‘1010 1010 1010 1010’ |
RBS-4301 |
|||||||
|
– Downlink 64QAM configured |
TRUE |
RBS-4302 |
|||||||
|
– HS-DSCH TB size table |
Not present |
RBS-4303 |
|||||||
|
– Primary CPICH info |
RBS-4304 |
||||||||
|
– Primary scrambling code |
Ref. to the Default setting in clause 6.1 (FDD) |
RBS-4305 |
|||||||
|
– DL Scrambling Code |
Not Present |
RBS-4306 |
|||||||
|
– HS-SCCH Channelisation Code Information |
RBS-4307 |
||||||||
|
– HS-SCCH Channelisation Code |
6 |
RBS-4308 |
|||||||
|
– HS-SCCH Channelisation Code |
7 |
RBS-4309 |
|||||||
|
– Measurement Power Offset |
6 dB |
RBS-4310 |
|||||||
|
– UARFCN downlink (Nd) |
Reference to clause 5.1 Test frequencies |
RBS-4311 |
|||||||
|
– Different Tx diversity mode configuration from serving HS-DSCH cell |
Not Present |
Rel-8 |
RBS-4312 |
||||||
|
– Secondary cell MIMO parameters |
Rel-9 |
RBS-4313 |
|||||||
|
– CHOICE Configuration info |
RBS-4314 |
||||||||
|
– Continue |
RBS-4315 |
||||||||
|
– New configuration |
RBS-4316 |
||||||||
|
– MIMO N_cqi_typeA/M_cqi ratio |
1/1 |
RBS-4317 |
|||||||
|
– MIMO pilot configuration |
RBS-4318 |
||||||||
|
-CHOICE Second CPICH pattern |
RBS-4319 |
||||||||
|
-Antenna2 P-CPICH |
No data |
RBS-4320 |
|||||||
|
-Antenna1 S-CPICH |
RBS-4321 |
||||||||
|
-Channelisation code |
29 |
RBS-4322 |
|||||||
|
Downlink secondary cell info FDD |
A35, A37 |
Rel-10 |
RBS-4323 |
||||||
|
– CHOICE Configuration info |
New configuration |
RBS-4324 |
|||||||
|
– New H-RNTI |
‘1010 1010 1010 1010’ |
RBS-4325 |
|||||||
|
– Downlink 64QAM configured |
TRUE |
RBS-4326 |
|||||||
|
– HS-DSCH TB size table |
Not present |
RBS-4327 |
|||||||
|
– Primary CPICH info |
RBS-4328 |
||||||||
|
– Primary scrambling code |
Ref. to the Default setting in clause 6.1 (FDD) |
RBS-4329 |
|||||||
|
– DL Scrambling Code |
Not Present |
RBS-4330 |
|||||||
|
– HS-SCCH Channelisation Code Information |
RBS-4331 |
||||||||
|
– HS-SCCH Channelisation Code |
6 |
RBS-4332 |
|||||||
|
– HS-SCCH Channelisation Code |
7 |
RBS-4333 |
|||||||
|
– Measurement Power Offset |
6 dB |
RBS-4334 |
|||||||
|
– UARFCN downlink (Nd) |
Reference to clause 5.1 Test frequencies |
RBS-4335 |
|||||||
|
– Different Tx diversity mode configuration from serving HS-DSCH cell |
Not Present |
Rel-8 |
RBS-4336 |
||||||
|
-Secondary cell MIMO parameters |
Not Present |
Rel-9 |
RBS-4337 |
||||||
|
Downlink secondary cell info FDD |
A38, A39, A40 |
Rel-11 |
RBS-4338 |
||||||
|
– CHOICE Configuration info |
New configuration |
RBS-4339 |
|||||||
|
– New H-RNTI |
‘1010 1010 1010 1010’ |
RBS-4340 |
|||||||
|
– Downlink 64QAM configured |
True |
RBS-4341 |
|||||||
|
– HS-DSCH TB size table |
Not present |
RBS-4342 |
|||||||
|
– Primary CPICH info |
RBS-4343 |
||||||||
|
– Primary scrambling code |
Ref. to the Default setting in clause 6.1 (FDD) |
RBS-4344 |
|||||||
|
– DL Scrambling Code |
Not Present |
RBS-4345 |
|||||||
|
– HS-SCCH Channelisation Code Information |
RBS-4346 |
||||||||
|
– HS-SCCH Channelisation Code |
6 |
RBS-4347 |
|||||||
|
– HS-SCCH Channelisation Code |
7 |
RBS-4348 |
|||||||
|
– Measurement Power Offset |
6 dB |
RBS-4349 |
|||||||
|
– UARFCN downlink (Nd) |
Reference to clause 5.1 Test frequencies |
RBS-4350 |
|||||||
|
– Different Tx diversity mode configuration from serving HS-DSCH cell |
Not Present |
Rel-8 |
RBS-4351 |
||||||
|
– multiflowConfigurationInfo |
Rel-11 |
RBS-4352 |
|||||||
|
– Multiflow cell |
Intra-NodeB |
RBS-4353 |
|||||||
|
– Multiflow time reference cell |
False |
RBS-4354 |
|||||||
|
-Secondary cell MIMO parameters |
Not Present |
Rel-9 |
RBS-4355 |
||||||
|
Additional downlink secondary cell info list FDD |
A39, A40 |
Rel-11 |
RBS-4356 |
||||||
|
Downlink secondary cell info FDD |
A39, A40 |
Rel-11 |
RBS-4357 |
||||||
|
– CHOICE Configuration info |
New configuration |
RBS-4358 |
|||||||
|
– New H-RNTI |
‘1010 1010 1010 1010’ |
RBS-4359 |
|||||||
|
– Downlink 64QAM configured |
True |
RBS-4360 |
|||||||
|
– HS-DSCH TB size table |
Not present |
RBS-4361 |
|||||||
|
– Primary CPICH info |
RBS-4362 |
||||||||
|
– Primary scrambling code |
Ref. to the Default setting in clause 6.1 (FDD) |
RBS-4363 |
|||||||
|
– DL Scrambling Code |
Not Present |
RBS-4364 |
|||||||
|
– HS-SCCH Channelisation Code Information |
RBS-4365 |
||||||||
|
– HS-SCCH Channelisation Code |
6 |
RBS-4366 |
|||||||
|
– HS-SCCH Channelisation Code |
7 |
RBS-4367 |
|||||||
|
– Measurement Power Offset |
6 dB |
RBS-4368 |
|||||||
|
– UARFCN downlink (Nd) |
Reference to clause 5.1 Test frequencies |
RBS-4369 |
|||||||
|
– Different Tx diversity mode configuration from serving HS-DSCH cell |
Not Present |
Rel-8 |
RBS-4370 |
||||||
|
– multiflowConfigurationInfo |
Rel-11 |
RBS-4371 |
|||||||
|
– Multiflow cell |
Intra-NodeB |
RBS-4372 |
|||||||
|
– Multiflow time reference cell |
True |
RBS-4373 |
|||||||
|
-Secondary cell MIMO parameters |
Not Present |
Rel-9 |
RBS-4374 |
||||||
|
Downlink secondary cell info FDD |
A40 |
Rel-11 |
RBS-4375 |
||||||
|
– CHOICE Configuration info |
New configuration |
RBS-4376 |
|||||||
|
– New H-RNTI |
‘1010 1010 1010 1010’ |
RBS-4377 |
|||||||
|
– Downlink 64QAM configured |
True |
RBS-4378 |
|||||||
|
– HS-DSCH TB size table |
Not present |
RBS-4379 |
|||||||
|
– Primary CPICH info |
RBS-4380 |
||||||||
|
– Primary scrambling code |
Ref. to the Default setting in clause 6.1 (FDD) |
RBS-4381 |
|||||||
|
– DL Scrambling Code |
Not Present |
RBS-4382 |
|||||||
|
– HS-SCCH Channelisation Code Information |
RBS-4383 |
||||||||
|
– HS-SCCH Channelisation Code |
6 |
RBS-4384 |
|||||||
|
– HS-SCCH Channelisation Code |
7 |
RBS-4385 |
|||||||
|
– Measurement Power Offset |
6 dB |
RBS-4386 |
|||||||
|
– UARFCN downlink (Nd) |
Reference to clause 5.1 Test frequencies |
RBS-4387 |
|||||||
|
– Different Tx diversity mode configuration from serving HS-DSCH cell |
Not Present |
Rel-8 |
RBS-4388 |
||||||
|
– multiflowConfigurationInfo |
Rel-11 |
RBS-4389 |
|||||||
|
– Multiflow cell |
Intra-NodeB |
RBS-4390 |
|||||||
|
– Multiflow time reference cell |
False |
RBS-4391 |
|||||||
|
-Secondary cell MIMO parameters |
Not Present |
Rel-9 |
RBS-4392 |
||||||
|
Downlink secondary cell info FDD |
A41, A42, A43 |
Rel-11 |
RBS-4393 |
||||||
|
– CHOICE Configuration info |
New configuration |
RBS-4394 |
|||||||
|
– New H-RNTI |
‘1010 1010 1010 1010’ |
RBS-4395 |
|||||||
|
– Downlink 64QAM configured |
False |
RBS-4396 |
|||||||
|
– HS-DSCH TB size table |
Octet Aligned |
RBS-4397 |
|||||||
|
– Primary CPICH info |
RBS-4398 |
||||||||
|
– Primary scrambling code |
Ref. to the Default setting in clause 6.1 (FDD) |
RBS-4399 |
|||||||
|
– DL Scrambling Code |
Not Present |
RBS-4400 |
|||||||
|
– HS-SCCH Channelisation Code Information |
RBS-4401 |
||||||||
|
– HS-SCCH Channelisation Code |
Refer to clause 5.5.1.3 |
RBS-4402 |
|||||||
|
– Measurement Power Offset |
6 dB |
RBS-4403 |
|||||||
|
– UARFCN downlink (Nd) |
Reference to clause 5.1 Test frequencies |
RBS-4404 |
|||||||
|
– Different Tx diversity mode configuration from serving HS-DSCH cell |
Not Present |
Rel-8 |
RBS-4405 |
||||||
|
– multiflowConfigurationInfo |
Rel-11 |
RBS-4406 |
|||||||
|
– Multiflow cell |
Intra-NodeB |
RBS-4407 |
|||||||
|
– Multiflow time reference cell |
False |
RBS-4408 |
|||||||
|
-Secondary cell MIMO parameters |
Not Present |
Rel-9 |
RBS-4409 |
||||||
|
Additional downlink secondary cell info list FDD |
A42, A43 |
Rel-11 |
RBS-4410 |
||||||
|
Downlink secondary cell info FDD |
A42, A43 |
Rel-11 |
RBS-4411 |
||||||
|
– CHOICE Configuration info |
New configuration |
RBS-4412 |
|||||||
|
– New H-RNTI |
‘1010 1010 1010 1010’ |
RBS-4413 |
|||||||
|
– Downlink 64QAM configured |
False |
RBS-4414 |
|||||||
|
– HS-DSCH TB size table |
Octet Aligned |
RBS-4415 |
|||||||
|
– Primary CPICH info |
RBS-4416 |
||||||||
|
– Primary scrambling code |
Ref. to the Default setting in clause 6.1 (FDD) |
RBS-4417 |
|||||||
|
– DL Scrambling Code |
Not Present |
RBS-4418 |
|||||||
|
– HS-SCCH Channelisation Code Information |
RBS-4419 |
||||||||
|
– HS-SCCH Channelisation Code |
Refer to clause 5.5.1.3 |
RBS-4420 |
|||||||
|
– Measurement Power Offset |
6 dB |
RBS-4421 |
|||||||
|
– UARFCN downlink (Nd) |
Reference to clause 5.1 Test frequencies |
RBS-4422 |
|||||||
|
– Different Tx diversity mode configuration from serving HS-DSCH cell |
Not Present |
Rel-8 |
RBS-4423 |
||||||
|
– multiflowConfigurationInfo |
Rel-11 |
RBS-4424 |
|||||||
|
– Multiflow cell |
Intra-NodeB |
RBS-4425 |
|||||||
|
– Multiflow time reference cell |
True |
RBS-4426 |
|||||||
|
-Secondary cell MIMO parameters |
Not Present |
Rel-9 |
RBS-4427 |
||||||
|
Downlink secondary cell info FDD |
A43 |
Rel-11 |
RBS-4428 |
||||||
|
– CHOICE Configuration info |
New configuration |
RBS-4429 |
|||||||
|
– New H-RNTI |
‘1010 1010 1010 1010’ |
RBS-4430 |
|||||||
|
– Downlink 64QAM configured |
False |
RBS-4431 |
|||||||
|
– HS-DSCH TB size table |
Octet Aligned |
RBS-4432 |
|||||||
|
– Primary CPICH info |
RBS-4433 |
||||||||
|
– Primary scrambling code |
Ref. to the Default setting in clause 6.1 (FDD) |
RBS-4434 |
|||||||
|
– DL Scrambling Code |
Not Present |
RBS-4435 |
|||||||
|
– HS-SCCH Channelisation Code Information |
RBS-4436 |
||||||||
|
– HS-SCCH Channelisation Code |
Refer to clause 5.5.1.3 |
RBS-4437 |
|||||||
|
– Measurement Power Offset |
6 dB |
RBS-4438 |
|||||||
|
– UARFCN downlink (Nd) |
Reference to clause 5.1 Test frequencies |
RBS-4439 |
|||||||
|
– Different Tx diversity mode configuration from serving HS-DSCH cell |
Not Present |
Rel-8 |
RBS-4440 |
||||||
|
– multiflowConfigurationInfo |
Rel-11 |
RBS-4441 |
|||||||
|
– Multiflow cell |
Intra-NodeB |
RBS-4442 |
|||||||
|
– Multiflow time reference cell |
False |
RBS-4443 |
|||||||
|
-Secondary cell MIMO parameters |
Not Present |
Rel-9 |
RBS-4444 |
||||||
|
Downlink secondary cell info FDD |
A44, A45 |
Rel-11 |
RBS-4445 |
||||||
|
– CHOICE Configuration info |
New configuration |
RBS-4446 |
|||||||
|
– New H-RNTI |
‘1010 1010 1010 1010’ |
RBS-4447 |
|||||||
|
– Downlink 64QAM configured |
False |
RBS-4448 |
|||||||
|
– HS-DSCH TB size table |
Octet Aligned |
RBS-4449 |
|||||||
|
– Primary CPICH info |
RBS-4450 |
||||||||
|
– Primary scrambling code |
Ref. to the Default setting in clause 6.1 (FDD) |
RBS-4451 |
|||||||
|
– DL Scrambling Code |
Not Present |
RBS-4452 |
|||||||
|
– HS-SCCH Channelisation Code Information |
RBS-4453 |
||||||||
|
– HS-SCCH Channelisation Code |
Refer to clause 5.5.1.3 |
RBS-4454 |
|||||||
|
– Measurement Power Offset |
6 dB |
RBS-4455 |
|||||||
|
– UARFCN downlink (Nd) |
Reference to clause 5.1 Test frequencies |
RBS-4456 |
|||||||
|
– Different Tx diversity mode configuration from serving HS-DSCH cell |
Not Present |
Rel-8 |
RBS-4457 |
||||||
|
– multiflowConfigurationInfo |
Rel-11 |
RBS-4458 |
|||||||
|
– Multiflow cell |
Inter-NodeB |
RBS-4459 |
|||||||
|
– Multiflow time reference cell |
True |
RBS-4460 |
|||||||
|
-Secondary cell MIMO parameters |
Not Present |
Rel-9 |
RBS-4461 |
||||||
|
Additional downlink secondary cell info list FDD |
A45 |
Rel-11 |
RBS-4462 |
||||||
|
Downlink secondary cell info FDD |
A45 |
Rel-11 |
RBS-4463 |
||||||
|
– CHOICE Configuration info |
New configuration |
RBS-4464 |
|||||||
|
– New H-RNTI |
‘1010 1010 1010 1010’ |
RBS-4465 |
|||||||
|
– Downlink 64QAM configured |
True |
RBS-4466 |
|||||||
|
– HS-DSCH TB size table |
Not present |
RBS-4467 |
|||||||
|
– Primary CPICH info |
RBS-4468 |
||||||||
|
– Primary scrambling code |
Ref. to the Default setting in clause 6.1 (FDD) |
RBS-4469 |
|||||||
|
– DL Scrambling Code |
Not Present |
RBS-4470 |
|||||||
|
– HS-SCCH Channelisation Code Information |
RBS-4471 |
||||||||
|
– HS-SCCH Channelisation Code |
Refer to clause 5.5.1.3 |
RBS-4472 |
|||||||
|
– Measurement Power Offset |
6 dB |
RBS-4473 |
|||||||
|
– UARFCN downlink (Nd) |
Reference to clause 5.1 Test frequencies |
RBS-4474 |
|||||||
|
– Different Tx diversity mode configuration from serving HS-DSCH cell |
Not Present |
Rel-8 |
RBS-4475 |
||||||
|
– multiflowConfigurationInfo |
Rel-11 |
RBS-4476 |
|||||||
|
– Multiflow cell |
Intra-NodeB |
RBS-4477 |
|||||||
|
– Multiflow time reference cell |
False |
RBS-4478 |
|||||||
|
-Secondary cell MIMO parameters |
Not Present |
Rel-9 |
RBS-4479 |
||||||
|
Additional downlink secondary cell info list FDD |
A33 |
Rel-10 |
RBS-4480 |
||||||
|
Downlink secondary cell info FDD |
A33 |
3rd Carrier (3C and 4C) |
Rel-10 |
RBS-4481 |
|||||
|
– CHOICE Configuration info |
New configuration |
RBS-4482 |
|||||||
|
– New H-RNTI |
‘1010 1010 1010 1010’ |
RBS-4483 |
|||||||
|
– Downlink 64QAM configured |
TRUE |
RBS-4484 |
|||||||
|
– HS-DSCH TB size table |
Not present |
RBS-4485 |
|||||||
|
– Primary CPICH info |
RBS-4486 |
||||||||
|
– Primary scrambling code |
Ref. to the Default setting in clause 6.1 (FDD) |
RBS-4487 |
|||||||
|
– DL Scrambling Code |
Not Present |
RBS-4488 |
|||||||
|
– HS-SCCH Channelisation Code Information |
RBS-4489 |
||||||||
|
– HS-SCCH Channelisation Code |
6 |
RBS-4490 |
|||||||
|
– HS-SCCH Channelisation Code |
7 |
RBS-4491 |
|||||||
|
– Measurement Power Offset |
6 dB |
RBS-4492 |
|||||||
|
– UARFCN downlink (Nd) |
Reference to clause 5.1 Test frequencies |
RBS-4493 |
|||||||
|
– Different Tx diversity mode configuration from serving HS-DSCH cell |
Not Present |
Rel-8 |
RBS-4494 |
||||||
|
– Secondary cell MIMO parameters |
Rel-9 |
RBS-4495 |
|||||||
|
– CHOICE Configuration info |
RBS-4496 |
||||||||
|
– Continue |
RBS-4497 |
||||||||
|
– New configuration |
RBS-4498 |
||||||||
|
– MIMO N_cqi_typeA/M_cqi ratio |
1/1 |
RBS-4499 |
|||||||
|
– MIMO pilot configuration |
RBS-4500 |
||||||||
|
-CHOICE Second CPICH pattern |
RBS-4501 |
||||||||
|
-Antenna2 P-CPICH |
No data |
RBS-4502 |
|||||||
|
-Antenna1 S-CPICH |
RBS-4503 |
||||||||
|
-Channelisation code |
29 |
RBS-4504 |
|||||||
|
-Power Offset for S-CPICH for MIMO |
0 |
RBS-4505 |
|||||||
|
– Precoding weight set restriction |
True |
RBS-4506 |
|||||||
|
Downlink secondary cell info FDD |
A33 |
4th Carrier (4C) |
Rel-10 |
RBS-4507 |
|||||
|
– CHOICE Configuration info |
New configuration |
RBS-4508 |
|||||||
|
– New H-RNTI |
‘1010 1010 1010 1010’ |
RBS-4509 |
|||||||
|
– Downlink 64QAM configured |
TRUE |
RBS-4510 |
|||||||
|
– HS-DSCH TB size table |
Not present |
RBS-4511 |
|||||||
|
– Primary CPICH info |
RBS-4512 |
||||||||
|
– Primary scrambling code |
Ref. to the Default setting in clause 6.1 (FDD) |
RBS-4513 |
|||||||
|
– DL Scrambling Code |
Not Present |
RBS-4514 |
|||||||
|
– HS-SCCH Channelisation Code Information |
RBS-4515 |
||||||||
|
– HS-SCCH Channelisation Code |
6 |
RBS-4516 |
|||||||
|
– HS-SCCH Channelisation Code |
7 |
RBS-4517 |
|||||||
|
– Measurement Power Offset |
6 dB |
RBS-4518 |
|||||||
|
– UARFCN downlink (Nd) |
Reference to clause 5.1 Test frequencies |
RBS-4519 |
|||||||
|
– Different Tx diversity mode configuration from serving HS-DSCH cell |
Not Present |
Rel-8 |
RBS-4520 |
||||||
|
– Secondary cell MIMO parameters |
Rel-9 |
RBS-4521 |
|||||||
|
– CHOICE Configuration info |
RBS-4522 |
||||||||
|
– Continue |
RBS-4523 |
||||||||
|
– New configuration |
RBS-4524 |
||||||||
|
– MIMO N_cqi_typeA/M_cqi ratio |
1/1 |
RBS-4525 |
|||||||
|
– MIMO pilot configuration |
RBS-4526 |
||||||||
|
-CHOICE Second CPICH pattern |
RBS-4527 |
||||||||
|
-Antenna2 P-CPICH |
No data |
RBS-4528 |
|||||||
|
-Antenna1 S-CPICH |
RBS-4529 |
||||||||
|
-Channelisation code |
29 |
RBS-4530 |
|||||||
|
-Power Offset for S-CPICH for MIMO |
0 |
RBS-4531 |
|||||||
|
– Precoding weight set restriction |
True |
RBS-4532 |
|||||||
|
Additional downlink secondary cell info list FDD |
A34 |
3rd Carrier (3C and 4C) |
Rel-10 |
RBS-4533 |
|||||
|
Downlink secondary cell info FDD |
A34 |
Rel-10 |
RBS-4534 |
||||||
|
– CHOICE Configuration info |
New configuration |
RBS-4535 |
|||||||
|
– New H-RNTI |
‘1010 1010 1010 1010’ |
RBS-4536 |
|||||||
|
– Downlink 64QAM configured |
Not Present |
RBS-4537 |
|||||||
|
– HS-DSCH TB size table |
Not Present |
RBS-4538 |
|||||||
|
– Primary CPICH info |
RBS-4539 |
||||||||
|
– Primary scrambling code |
Ref. to the Default setting in clause 6.1 (FDD) |
RBS-4540 |
|||||||
|
– DL Scrambling Code |
Not Present |
RBS-4541 |
|||||||
|
– HS-SCCH Channelisation Code Information |
RBS-4542 |
||||||||
|
– HS-SCCH Channelisation Code |
7 |
RBS-4543 |
|||||||
|
– Measurement Power Offset |
6 dB |
RBS-4544 |
|||||||
|
– UARFCN downlink (Nd) |
Reference to clause 5.1 Test frequencies |
RBS-4545 |
|||||||
|
– Different Tx diversity mode configuration from serving HS-DSCH cell |
Not Present |
Rel-8 |
RBS-4546 |
||||||
|
-Secondary cell MIMO parameters |
Rel-9 |
RBS-4547 |
|||||||
|
– CHOICE Configuration info |
RBS-4548 |
||||||||
|
– Continue |
RBS-4549 |
||||||||
|
– New configuration |
RBS-4550 |
||||||||
|
– MIMO N_cqi_typeA/M_cqi ratio |
1/1 |
RBS-4551 |
|||||||
|
– MIMO pilot configuration |
RBS-4552 |
||||||||
|
-CHOICE Second CPICH pattern |
RBS-4553 |
||||||||
|
-Antenna2 P-CPICH |
No data |
RBS-4554 |
|||||||
|
-Antenna1 S-CPICH |
RBS-4555 |
||||||||
|
-Channelisation code |
13 |
RBS-4556 |
|||||||
|
-Power Offset for S-CPICH for MIMO |
0 |
RBS-4557 |
|||||||
|
– Precoding weight set restriction |
True |
RBS-4558 |
|||||||
|
Downlink secondary cell info FDD |
A34 |
4th Carrier (4C) |
Rel-10 |
RBS-4559 |
|||||
|
– CHOICE Configuration info |
New configuration |
RBS-4560 |
|||||||
|
– New H-RNTI |
‘1010 1010 1010 1010’ |
RBS-4561 |
|||||||
|
– Downlink 64QAM configured |
Not Present |
RBS-4562 |
|||||||
|
– HS-DSCH TB size table |
Not Present |
RBS-4563 |
|||||||
|
– Primary CPICH info |
RBS-4564 |
||||||||
|
– Primary scrambling code |
Ref. to the Default setting in clause 6.1 (FDD) |
RBS-4565 |
|||||||
|
– DL Scrambling Code |
Not Present |
RBS-4566 |
|||||||
|
– HS-SCCH Channelisation Code Information |
RBS-4567 |
||||||||
|
– HS-SCCH Channelisation Code |
7 |
RBS-4568 |
|||||||
|
– Measurement Power Offset |
6 dB |
RBS-4569 |
|||||||
|
– UARFCN downlink (Nd) |
Reference to clause 5.1 Test frequencies |
RBS-4570 |
|||||||
|
– Different Tx diversity mode configuration from serving HS-DSCH cell |
Not Present |
Rel-8 |
RBS-4571 |
||||||
|
-Secondary cell MIMO parameters |
Rel-9 |
RBS-4572 |
|||||||
|
– CHOICE Configuration info |
RBS-4573 |
||||||||
|
– Continue |
RBS-4574 |
||||||||
|
– New configuration |
RBS-4575 |
||||||||
|
– MIMO N_cqi_typeA/M_cqi ratio |
1/1 |
RBS-4576 |
|||||||
|
– MIMO pilot configuration |
RBS-4577 |
||||||||
|
-CHOICE Second CPICH pattern |
RBS-4578 |
||||||||
|
-Antenna2 P-CPICH |
No data |
RBS-4579 |
|||||||
|
-Antenna1 S-CPICH |
RBS-4580 |
||||||||
|
-Channelisation code |
13 |
RBS-4581 |
|||||||
|
-Power Offset for S-CPICH for MIMO |
0 |
RBS-4582 |
|||||||
|
– Precoding weight set restriction |
True |
RBS-4583 |
|||||||
|
Additional downlink secondary cell info list FDD |
A35 |
3rd Carrier (3C and 4C) |
Rel-10 |
RBS-4584 |
|||||
|
Downlink secondary cell info FDD |
A35 |
Rel-10 |
RBS-4585 |
||||||
|
– CHOICE Configuration info |
New configuration |
RBS-4586 |
|||||||
|
– New H-RNTI |
‘1010 1010 1010 1010’ |
RBS-4587 |
|||||||
|
– Downlink 64QAM configured |
TRUE |
RBS-4588 |
|||||||
|
– HS-DSCH TB size table |
Not present |
RBS-4589 |
|||||||
|
– Primary CPICH info |
RBS-4590 |
||||||||
|
– Primary scrambling code |
Ref. to the Default setting in clause 6.1 (FDD) |
RBS-4591 |
|||||||
|
– DL Scrambling Code |
Not Present |
RBS-4592 |
|||||||
|
– HS-SCCH Channelisation Code Information |
RBS-4593 |
||||||||
|
– HS-SCCH Channelisation Code |
6 |
RBS-4594 |
|||||||
|
– HS-SCCH Channelisation Code |
7 |
RBS-4595 |
|||||||
|
– Measurement Power Offset |
6 dB |
RBS-4596 |
|||||||
|
– UARFCN downlink (Nd) |
Reference to clause 5.1 Test frequencies |
RBS-4597 |
|||||||
|
– Different Tx diversity mode configuration from serving HS-DSCH cell |
Not Present |
Rel-8 |
RBS-4598 |
||||||
|
-Secondary cell MIMO parameters |
Not Present |
Rel-9 |
RBS-4599 |
||||||
|
Downlink secondary cell info FDD |
A35 |
4th Carrier (4C) |
Rel-10 |
RBS-4600 |
|||||
|
– CHOICE Configuration info |
New configuration |
RBS-4601 |
|||||||
|
– New H-RNTI |
‘1010 1010 1010 1010’ |
RBS-4602 |
|||||||
|
– Downlink 64QAM configured |
TRUE |
RBS-4603 |
|||||||
|
– HS-DSCH TB size table |
Not present |
RBS-4604 |
|||||||
|
– Primary CPICH info |
RBS-4605 |
||||||||
|
– Primary scrambling code |
Ref. to the Default setting in clause 6.1 (FDD) |
RBS-4606 |
|||||||
|
– DL Scrambling Code |
Not Present |
RBS-4607 |
|||||||
|
– HS-SCCH Channelisation Code Information |
RBS-4608 |
||||||||
|
– HS-SCCH Channelisation Code |
6 |
RBS-4609 |
|||||||
|
– HS-SCCH Channelisation Code |
7 |
RBS-4610 |
|||||||
|
– Measurement Power Offset |
6 dB |
RBS-4611 |
|||||||
|
– UARFCN downlink (Nd) |
Reference to clause 5.1 Test frequencies |
RBS-4612 |
|||||||
|
– Different Tx diversity mode configuration from serving HS-DSCH cell |
Not Present |
Rel-8 |
RBS-4613 |
||||||
|
-Secondary cell MIMO parameters |
Not Present |
Rel-9 |
RBS-4614 |
||||||
|
Additional downlink secondary cell info list FDD |
A36 |
Rel-10 |
RBS-4615 |
||||||
|
Downlink secondary cell info FDD |
A36 |
3rd Carrier (3C and 4C) |
Rel-10 |
RBS-4616 |
|||||
|
– CHOICE Configuration info |
New configuration |
RBS-4617 |
|||||||
|
– New H-RNTI |
‘1010 1010 1010 1010’ |
RBS-4618 |
|||||||
|
– Downlink 64QAM configured |
Not Present |
RBS-4619 |
|||||||
|
– HS-DSCH TB size table |
Octet Aligned |
RBS-4620 |
|||||||
|
– Primary CPICH info |
RBS-4621 |
||||||||
|
– Primary scrambling code |
Ref. to the Default setting in clause 6.1 (FDD) |
RBS-4622 |
|||||||
|
– DL Scrambling Code |
Not Present |
RBS-4623 |
|||||||
|
– HS-SCCH Channelisation Code Information |
RBS-4624 |
||||||||
|
– HS-SCCH Channelisation Code |
7 |
RBS-4625 |
|||||||
|
– Measurement Power Offset |
6 dB |
RBS-4626 |
|||||||
|
– UARFCN downlink (Nd) |
Reference to clause 5.1 Test frequencies |
RBS-4627 |
|||||||
|
– Different Tx diversity mode configuration from serving HS-DSCH cell |
Not Present |
Rel-8 |
RBS-4628 |
||||||
|
-Secondary cell MIMO parameters |
Not Present |
Rel-9 |
RBS-4629 |
||||||
|
Downlink secondary cell info FDD |
A36 |
4th Carrier (4C) |
Rel-10 |
RBS-4630 |
|||||
|
– CHOICE Configuration info |
New configuration |
RBS-4631 |
|||||||
|
– New H-RNTI |
‘1010 1010 1010 1010’ |
RBS-4632 |
|||||||
|
– Downlink 64QAM configured |
Not Present |
RBS-4633 |
|||||||
|
– HS-DSCH TB size table |
Octet Aligned |
RBS-4634 |
|||||||
|
– Primary CPICH info |
RBS-4635 |
||||||||
|
– Primary scrambling code |
Ref. to the Default setting in clause 6.1 (FDD) |
RBS-4636 |
|||||||
|
– DL Scrambling Code |
Not Present |
RBS-4637 |
|||||||
|
– HS-SCCH Channelisation Code Information |
RBS-4638 |
||||||||
|
– HS-SCCH Channelisation Code |
7 |
RBS-4639 |
|||||||
|
– Measurement Power Offset |
6 dB |
RBS-4640 |
|||||||
|
– UARFCN downlink (Nd) |
Reference to clause 5.1 Test frequencies |
RBS-4641 |
|||||||
|
– Different Tx diversity mode configuration from serving HS-DSCH cell |
Not Present |
Rel-8 |
RBS-4642 |
||||||
|
-Secondary cell MIMO parameters |
Not Present |
Rel-9 |
RBS-4643 |
||||||
|
Additional downlink secondary cell info list FDD |
A37 |
Rel-10 |
RBS-4644 |
||||||
|
Downlink secondary cell info FDD |
A37 |
3rd Carrier (3C and 4C) |
Rel-10 |
RBS-4645 |
|||||
|
– CHOICE Configuration info |
New configuration |
RBS-4646 |
|||||||
|
– New H-RNTI |
‘1010 1010 1010 1010’ |
RBS-4647 |
|||||||
|
– Downlink 64QAM configured |
TRUE |
RBS-4648 |
|||||||
|
– HS-DSCH TB size table |
Not present |
RBS-4649 |
|||||||
|
– Primary CPICH info |
RBS-4650 |
||||||||
|
– Primary scrambling code |
Ref. to the Default setting in clause 6.1 (FDD) |
RBS-4651 |
|||||||
|
– DL Scrambling Code |
Not Present |
RBS-4652 |
|||||||
|
– HS-SCCH Channelisation Code Information |
RBS-4653 |
||||||||
|
– HS-SCCH Channelisation Code |
6 |
RBS-4654 |
|||||||
|
– HS-SCCH Channelisation Code |
7 |
RBS-4655 |
|||||||
|
– Measurement Power Offset |
6 dB |
RBS-4656 |
|||||||
|
– UARFCN downlink (Nd) |
Reference to clause 5.1 Test frequencies |
RBS-4657 |
|||||||
|
– Different Tx diversity mode configuration from serving HS-DSCH cell |
Not Present |
Rel-8 |
RBS-4658 |
||||||
|
-Secondary cell MIMO parameters |
Not Present |
Rel-9 |
RBS-4659 |
||||||
|
Downlink secondary cell info FDD |
A37 |
4th Carrier (4C) |
Rel-10 |
RBS-4660 |
|||||
|
– CHOICE Configuration info |
New configuration |
RBS-4661 |
|||||||
|
– New H-RNTI |
‘1010 1010 1010 1010’ |
RBS-4662 |
|||||||
|
– Downlink 64QAM configured |
TRUE |
RBS-4663 |
|||||||
|
– HS-DSCH TB size table |
Not present |
RBS-4664 |
|||||||
|
– Primary CPICH info |
RBS-4665 |
||||||||
|
– Primary scrambling code |
Ref. to the Default setting in clause 6.1 (FDD) |
RBS-4666 |
|||||||
|
– DL Scrambling Code |
Not Present |
RBS-4667 |
|||||||
|
– HS-SCCH Channelisation Code Information |
RBS-4668 |
||||||||
|
– HS-SCCH Channelisation Code |
6 |
RBS-4669 |
|||||||
|
– HS-SCCH Channelisation Code |
7 |
RBS-4670 |
|||||||
|
– Measurement Power Offset |
6 dB |
RBS-4671 |
|||||||
|
– UARFCN downlink (Nd) |
Reference to clause 5.1 Test frequencies |
RBS-4672 |
|||||||
|
– Different Tx diversity mode configuration from serving HS-DSCH cell |
Not Present |
Rel-8 |
RBS-4673 |
||||||
|
-Secondary cell MIMO parameters |
Not Present |
Rel-9 |
RBS-4674 |
||||||
|
MBMS PL Service Restriction Information |
A1, A2, A3, A4, A5, A6, A7, A8 |
Not Present |
RBS-4675 |
||||||
|
A9, A10 |
Rel-5 |
RBS-4676 |
|||||||
|
, A12, A13, A14, A15, A16 |
Rel-6 |
RBS-4677 |
|||||||
|
, A17, A17a, A17b, A17c, , A17f A18, A19, A19a, A20, A21, A22 |
Rel-7 |
RBS-4678 |
|||||||
|
, A23, A24, A28a |
Rel-7 Rel-8 |
RBS-4679 |
|||||||
|
, A25, A25a, A26, A27, A27a, A28, A29, A30 |
Rel-8 |
RBS-4680 |
|||||||
|
, A31, A32 , A33, A34, A35, A36, A37 A38, A39, A40, A41, A42, A43, A44, A45 |
Rel-9 Rel-10 Rel-11 |
RBS-4681 |
|||||||
|
Condition |
Explanation |
Version |
|
A1 |
This IE is needed for "Non speech to CELL_DCH from CELL_DCH in CS" |
|
|
A2 |
This IE is needed for "Speech to CELL_DCH from CELL_DCH in CS" |
|
|
A3 |
This IE is needed for "Packet to CELL_DCH from CELL_DCH in PS" |
|
|
A4 |
This IE is needed for "Packet to CELL_DCH from CELL_FACH in PS" |
|
|
A5 |
This IE is needed for "Packet to CELL_FACH from CELL_DCH in PS" |
|
|
A6 |
This IE is needed for "Packet to CELL_FACH from CELL_FACH in PS" |
|
|
A7 |
This IE is needed for "Non speech to CELL_DCH from CELL_FACH in CS" |
|
|
A8 |
This IE is needed for "Speech to CELL_DCH from CELL_FACH in CS" |
|
|
A9 |
This IE is needed for "Packet to CELL_DCH / HS-DSCH using three multiplexing options", or when not stated otherwise, for "Packet to CELL_DCH / HS-DSCH from CELL_DCH in PS" |
Rel-5 |
|
A10 |
This IE is needed for "Packet to CELL_DCH / HS-DSCH using one multiplexing option", or when not stated otherwise, for "Packet to CELL_DCH / HS-DSCH from CELL_FACH in PS" |
Rel-5 |
|
A11 |
This IE is needed for " Packet RAB Setup after Speech RAB Setup in CELL_DCH" |
|
|
A12 |
This IE is needed for "Packet to CELL_DCH / E-DCH / HS-DSCH using three multiplexing options (3/3) and SRBs mapped on DCH/DCH" |
Rel-6 |
|
A13 |
This IE is needed for "Packet to CELL_DCH / E-DCH / HS-DSCH using one multiplexing option (1/1) and SRBs mapped on E-DCH/DCH" |
Rel-6 |
|
A14 |
This IE is needed for "Packet to CELL_DCH / E-DCH / HS-DSCH using one multiplexing option (1/1) and SRBs mapped on E-DCH/HS-DSCH" |
Rel-6 |
|
A15 |
This IE is needed for "Packet to CELL_DCH / E-DCH / HS-DSCH with multiple RABs (two streaming/interactive/background) using one multiplexing option (1/1) and SRBs mapped on E-DCH/DCH” |
Rel-6 |
|
A16 |
This IE is needed for "Packet to CELL_DCH / E-DCH / HS-DSCH with multiple RABs (one conversational and one streaming/interactive/background) using one multiplexing option (1/1) and SRBs mapped on E-DCH/HS-DSCH” |
Rel-6 |
|
A17 |
This IE is needed for "Packet to CELL_DCH / HS-DSCH with enhanced data rate and RLC AM" |
Rel-7 |
|
A17a |
This IE is needed for "Packet to CELL_DCH / HS-DSCH [DL : 64QAM] with enhanced data rate and RLC AM" |
Rel-7 |
|
A17b |
This IE is needed for "Packet to CELL_DCH / HS-DSCH with enhanced data rate and RLC AM using one multiplexing option (1/1) and SRBs mapped on E-DCH/HS-DSCH (MAC-ehs)" |
Rel-7 |
|
A17c |
This IE is needed for "Packet to CELL_DCH / HS-DSCH [DL : 64QAM] with enhanced data rate and RLC AM using one multiplexing option (1/1) and SRBs mapped on E-DCH/HS-DSCH (MAC-ehs)" |
Rel-7 |
|
A17d |
This IE is needed for "Packet to CELL_DCH / HS-DSCH with enhanced data rate and RLC AM using one multiplexing option (1/1) and SRBs mapped on E-DCH/DCH (MAC-ehs)" |
Rel-7 |
|
A17e |
This IE is needed for "Packet to CELL_DCH / HS-DSCH [DL : 64QAM] with enhanced data rate and RLC AM using one multiplexing option (1/1) and SRBs mapped on E-DCH/DCH (MAC-ehs)" |
Rel-7 |
|
A17f |
This IE is needed for "Packet to CELL_DCH / E-DCH / HS-DSCH [DL : 64QAM] with enhanced rate and RLC AM using one multiplexing option (1/1) and SRBs mapped on DCH" |
Rel-7 |
|
A18 |
This IE is needed for "Packet to CELL_DCH / HS-DSCH with enhanced data rate and RLC UM" |
Rel-7 |
|
A19 |
This IE is needed for "Packet to CELL_DCH / E-DCH[UL : 16QAM] / HS-DSCH using three multiplexing options (3/3) and SRBs mapped on DCH/DCH" |
Rel-7 |
|
A19a |
This IE is needed for "Packet to CELL_DCH / E-DCH[UL : 16QAM] / HS-DSCH using one multiplexing option (1/1) and SRBs mapped on E-DCH/DCH" |
Rel-7 |
|
A19b |
This IE is needed for "Packet to CELL_DCH / E-DCH[UL: 16QAM] / HS-DSCH with multiple RABs (one conversational and one streaming/interactive/background) using one multiplexing option (1/1) and SRBs mapped on E-DCH/HS-DSCH" |
Rel-7 |
|
A20 |
This IE is needed for "Packet to CELL_DCH / E-DCH / HS-DSCH with DTX/DRX using one multiplexing option (1/1) and SRBs mapped on E-DCH/HS-DSCH" |
Rel-7 |
|
A21 |
This IE is needed for "Packet to CELL_DCH / E-DCH / HS-DSCH with DTX/DRX and multiple RABs (one conversational and one streaming/interactive/background) using one multiplexing option (1/1) and SRBs mapped on E-DCH/HS-DSCH” |
Rel-7 |
|
A22 |
This IE is needed for "Packet to CELL_DCH / E-DCH / HS-DSCH with multiple RABs (one conversational and one streaming/interactive/background) with enhanced data rate using one multiplexing option (1/1) and SRBs mapped on E-DCH/HS-DSCH” |
Rel-7 |
|
A23 |
This IE is needed for “Speech to CELL_DCH / E-DCH / HS-DSCH CS RAB with DTX/DRX and enhanced data rate using one multiplexing option (1/1) and SRBs mapped on E-DCH/HS-DSCH” |
Rel-7 Rel-8 (Note 1) |
|
A24 |
This IE is needed for “Packet to CELL_FACH from CELL_FACH using one multiplexing option (1/1) and SRBs mapped on RACH/HS-DSCH” |
Rel-7 |
|
A25 |
This IE is needed for "Packet to CELL_DCH / E-DCH / HS-DSCH [Dual Carrier Adjacent Channels] with enhanced data rate using one multiplexing option (1/1) and SRBs mapped on E-DCH( MACe/es ) /HS-DSCH”" |
Rel-8 |
|
A25a |
This IE is needed for “Packet to CELL_DCH / HS-DSCH [Dual Carrier Adjacent Channels] with enhanced data rate and RLC AM and SRBs mapped on DCH/DCH” |
Rel-8 |
|
A25b |
This IE is needed for "Packet to CELL_DCH / E-DCH ( MACe/es ) / HS-DSCH [Dual Carrier Adjacent Channels] with enhanced data rate using one multiplexing option (1/1) and SRBs mapped on E-DCH/DCH” |
Rel-8 |
|
A25c |
This IE is needed for "Packet to CELL_DCH / E-DCH ( MACi/is ) [Dual-Cell] / HS-DSCH [Dual Carrier Adjacent Channels] with enhanced data rate using one multiplexing option (1/1) and SRBs mapped on E-DCH/ HS-DSCH” |
Rel-9 |
|
A26 |
This IE is needed for "UM Packet to CELL_DCH / E-DCH (MAC-i/is) / HS-DSCH (MAC-ehs) with multiple RABs (three streaming/interactive/background) using one multiplexing option (1/1) and SRBs mapped on E-DCH (MAC-i/is)/DCH” |
Rel-8 |
|
A27 |
This IE is needed for "UM Packet to CELL_DCH / E-DCH (MAC-i/is) / HS-DSCH (MAC-ehs) using one multiplexing option (1/1) and SRBs mapped on E-DCH (MAC-i/is)/HS-DSCH (MAC-ehs)" |
Rel-8 |
|
A27a |
This IE is needed for "UM Packet to CELL_DCH / E-DCH [UL : 16QAM] (MAC-i/is) / HS-DSCH (MAC-ehs) using one multiplexing option (1/1) and SRBs mapped on E-DCH (MAC-i/is)/HS-DSCH” |
Rel-8 |
|
A28 |
This IE is needed for "Packet to CELL_DCH / HS-DSCH [DL : 64QAM+MIMO] with enhanced data rate and RLC AM" |
Rel-8 |
|
A28a |
This IE is needed for "Packet to CELL_DCH / HS-DSCH [DL : 16QAM+MIMO] with enhanced data rate and RLC AM" |
Rel-7 |
|
A29 |
This IE is needed for "AM Packet to Enhanced CELL_FACH from Enhanced CELL_FACH in PS with SRBs mapped on common E-DCH/HS-DSCH" |
Rel-8 |
|
A30 |
This IE is needed for “AM Packet to CELL_DCH from Enhanced CELL_FACH in PS with SRBs mapped on E-DCH (MAC-i/is)/HS-DSCH(MAC-ehs)” |
Rel-8 |
|
A31 |
This IE is needed for "Packet to CELL_DCH / HS-DSCH [UL: E-DCH DL: DC-HSDPA and MIMO] with enhanced data rate and RLC AM" |
Rel-9 |
|
A32 |
This IE is needed for "Packet to CELL_DCH / HS-DSCH [UL: E-DCH DL: 64QAM, DC-HSDPA and MIMO] with enhanced data rate and RLC AM" |
Rel-9 |
|
A33 |
This IE is needed for "Packet to CELL_DCH / HS-DSCH [UL: E-DCH DL: 64QAM, 4C-HSDPA and MIMO] with enhanced data rate and RLC AM and SRBs mapped on E-DCH (MAC-i/is)/HS-DSCH (MAC-ehs)" |
Rel-10 |
|
A34 |
This IE is needed for "Packet to CELL_DCH / HS-DSCH [UL: E-DCH DL: 16QAM, 4C-HSDPA and MIMO] with enhanced data rate and RLC AM and SRBs mapped on E-DCH (MAC-i/is)/HS-DSCH (MAC-ehs)" |
Rel-10 |
|
A35 |
This IE is needed for "Packet to CELL_DCH / HS-DSCH [UL: E-DCH DL: 64QAM, 4C-HSDPA] with enhanced data rate and RLC AM and SRBs mapped on DCH/DCH " |
Rel-10 |
|
A36 |
This IE is needed for "Packet to CELL_DCH / HS-DSCH [UL: E-DCH DL: 16QAM, 4C-HSDPA] with enhanced data rate and RLC AM and SRBs mapped on E-DCH (MAC-i/is)/HS-DSCH (MAC-ehs)" |
Rel-10 |
|
A37 |
This IE is needed for "Packet to CELL_DCH / HS-DSCH [UL: E-DCH DL: 64QAM, 4C-HSDPA] with enhanced data rate and RLC AM and SRBs mapped on E-DCH (MAC-i/is)/HS-DSCH (MAC-ehs)" |
Rel-10 |
|
A38 |
This IE is needed for "Packet to CELL_DCH / HS-DSCH [UL: E-DCH DL: 64QAM, SF-2C-HSDPA] with enhanced data rate and RLC AM and SRBs mapped on DCH/DCH " |
Rel-11 |
|
A39 |
This IE is needed for "Packet to CELL_DCH / HS-DSCH [UL: E-DCH DL: 64QAM, DF-3C-HSDPA] with enhanced data rate and RLC AM and SRBs mapped on DCH/DCH " |
Rel-11 |
|
A40 |
This IE is needed for "Packet to CELL_DCH / HS-DSCH [UL: E-DCH DL: 64QAM, DF-4C-HSDPA] with enhanced data rate and RLC AM and SRBs mapped on DCH/DCH " |
Rel-11 |
|
A41 |
This IE is needed for "Packet to CELL_DCH / HS-DSCH [UL: E-DCH DL: 16QAM, SF-2C-HSDPA] with enhanced data rate and RLC AM and SRBs mapped on DCH/DCH " |
Rel-11 |
|
A42 |
This IE is needed for "Packet to CELL_DCH / HS-DSCH [UL: E-DCH DL: 16QAM, DF-3C-HSDPA] with enhanced data rate and RLC AM and SRBs mapped on DCH/DCH " |
Rel-11 |
|
A43 |
This IE is needed for "Packet to CELL_DCH / HS-DSCH [UL: E-DCH DL: 16QAM, DF-4C-HSDPA] with enhanced data rate and RLC AM and SRBs mapped on DCH/DCH " |
Rel-11 |
|
A44 |
This IE is needed for "Packet to CELL_DCH / HS-DSCH [UL: E-DCH DL: 16QAM/64QAM, SF-2C-HSDPA and Inter-Node B] with enhanced data rate and RLC AM and SRBs mapped on DCH/DCH " |
Rel-11 |
|
A45 |
This IE is needed for "Packet to CELL_DCH / HS-DSCH [UL: E-DCH DL: 16QAM/64QAM, DF-3C-HSDPA and Inter-Node B] with enhanced data rate and RLC AM and SRBs mapped on DCH/DCH " |
Rel-11 |
NOTE 1: Support depends on the UE capability: Support for CS voice over HSPA. This is supported in Rel-8 and may be supported in Rel-7.
|
Condition |
Explanation |
Version |
|
MAC-I-FIXED |
Used with other condition when MAC-i/is with Fixed RLC PDU size is configured |
Rel-8 |
|
MAC-I-FLEX |
Used with other condition when MAC-i/is with Flexible RLC PDU size is configured |
Rel-8 |
Contents of RADIO BEARER SETUP message: AM or UM, for MBMS PtP Radio Bearer Setup
|
Information Element |
Condition |
Value/remark |
|---|---|---|
|
– RAB information for setup |
||
|
– RAB info |
(UM DTCH for PS domain DL only) |
|
|
– RAB identity |
11111111B For Selected Service and Set to same as Enhanced NSAPI received in Service Request (10000000B to 11111110B) for Multicast service. The first/ leftmost bit of the bit string contains the most significant bit of the RAB identity. |
|
|
– CN domain identity |
PS domain |
|
|
– NAS Synchronization Indicator |
Not Present |
|
|
– Re-establishment timer |
useT315 |
|
|
– RB information to setup |
||
|
– RB identity |
21 |
|
|
– MBMS Service Identity |
Present for Selected Service only |
|
|
– MBMS Service ID |
MBMS Service ID of the service UE has selected |
|
|
– MBMS Session identity |
||
|
– MBMS Session ID |
Ongoing Session ID |
|
|
– PDCP info |
||
|
– Support for lossless SRNS relocation |
FALSE |
|
|
– Max PDCP SN window size |
Not present |
|
|
– PDCP PDU header |
Absent |
|
|
– Header compression information |
Not present |
|
|
– CHOICE RLC info type |
RLC info |
|
|
– CHOICE Uplink RLC mode |
Not Present |
|
|
– CHOICE Downlink RLC mode |
UM RLC |
|
|
– DL UM RLC LI size |
7 |
|
|
– DL Reception Window Size |
Not Present |
|
|
– RB mapping info |
||
|
– Information for each multiplexing option |
1 RBMuxOptions |
|
|
– RLC logical channel mapping indicator |
Not Present |
|
|
– Number of uplink RLC logical channels |
Not Present |
|
|
– Downlink RLC logical channel info |
||
|
– Number of downlink RLC logical channels |
1 |
|
|
– Downlink transport channel type |
DCH |
|
|
– DL DCH Transport channel identity |
7 |
|
|
– DL DSCH Transport channel identity |
Not Present |
|
|
– Logical channel identity |
Not Present |
|
|
Added or Reconfigured UL TrCH information |
B5, B2 |
5 DCH reconfigured |
|
– Uplink transport channel type |
DCH |
|
|
– UL Transport channel identity |
5 |
|
|
– TFS |
||
|
– CHOICE Transport channel type |
Dedicated transport channels |
|
|
– Dynamic Transport format information |
||
|
– RLC Size |
Reference to clause 6. 11.1b Parameter Set |
|
|
– Number of TBs and TTI List |
(This IE is repeated for TFI number.) |
|
|
– Transmission Time Interval |
Not Present |
|
|
– Number of Transport blocks |
Reference to clause 6. 11.1b Parameter Set |
|
|
– CHOICE Logical channel list |
All |
|
|
– Semi-static Transport Format information |
||
|
– Transmission time interval |
Reference to clause 6. 11.1b Parameter Set |
|
|
– Type of channel coding |
Reference to clause 6. 11.1b Parameter Set |
|
|
– Coding Rate |
Reference to clause 6. 11.1b Parameter Set |
|
|
– Rate matching attribute |
Reference to clause 6. 11.1b Parameter Set |
|
|
– CRC size |
Reference to clause 6. 11.1b Parameter Set |
|
|
Added or Reconfigured DL TrCH information |
B1, B2 |
2 TrCHs(DCH for DCCH and 1 DCH for DTCH) |
|
– Downlink transport channel type |
DCH |
|
|
– DL Transport channel identity |
10 |
|
|
– CHOICE DL parameters |
Same as UL |
|
|
– Uplink transport channel type |
DCH |
|
|
– UL TrCH identity |
5 |
|
|
– DCH quality target |
||
|
– BLER Quality value |
-20 (-2.0) |
|
|
– Downlink transport channel type |
DCH |
|
|
– DL Transport channel identity |
7 |
|
|
– CHOICE DL parameters |
Explicit |
|
|
– TFS |
||
|
– CHOICE Transport channel type |
Dedicated transport channel |
|
|
– Dynamic transport format information |
||
|
– RLC Size |
Reference to clause 6. 11.1b Parameter Set |
|
|
– Number of TBs and TTI List |
(This IE is repeated for TFI number.) |
|
|
– Transmission Time Interval |
Not Present |
|
|
– Number of Transport blocks |
Reference to clause 6. 11.1b Parameter Set only including TF0 |
|
|
– CHOICE Logical channel list |
All |
|
|
– Semi-static Transport Format information |
||
|
– Transmission time interval |
Reference to clause 6. 11.1b Parameter Set |
|
|
– Type of channel coding |
Reference to clause 6. 11.1b Parameter Set |
|
|
– Coding Rate |
Reference to clause 6. 11.1b Parameter Set |
|
|
– Rate matching attribute |
Reference to clause 6. 11.1b Parameter Set |
|
|
– CRC size |
Reference to clause 6. 11.1b Parameter Set |
|
|
– DCH quality target |
||
|
– BLER Quality value |
-20 (-2.0) |
|
|
Added or Reconfigured DL TrCH information |
B3, B4 |
3 TrCHs(DCH for DCCH and 2 DCH for DTCH’s) |
|
– Downlink transport channel type |
DCH |
|
|
– DL Transport channel identity |
10 |
|
|
– CHOICE DL parameters |
Same as UL |
|
|
– Uplink transport channel type |
DCH |
|
|
– UL TrCH identity |
5 |
|
|
– DCH quality target |
||
|
– BLER Quality value |
-20 (-2.0) |
|
|
– Downlink transport channel type |
DCH |
|
|
– DL Transport channel identity |
6 |
|
|
– CHOICE DL parameters |
Same as UL |
|
|
– Uplink transport channel type |
DCH |
|
|
– UL TrCH identity |
1 |
|
|
– DCH quality target |
||
|
– BLER Quality value |
-20 (-2.0) |
|
|
– Downlink transport channel type |
DCH |
|
|
– DL Transport channel identity |
7 |
|
|
– CHOICE DL parameters |
Explicit |
|
|
– TFS |
||
|
– CHOICE Transport channel type |
Dedicated transport channel |
|
|
– Dynamic transport format information |
||
|
– RLC Size |
Reference to clause 6. 11.1a Parameter Set |
|
|
– Number of TBs and TTI List |
(This IE is repeated for TFI number.) |
|
|
– Transmission Time Interval |
Not Present |
|
|
– Number of Transport blocks |
Reference to clause 6. 11.1a Parameter |
|
|
– CHOICE Logical channel list |
All |
|
|
– Semi-static Transport Format information |
||
|
– Transmission time interval |
Reference to clause 6. 11.1a Parameter Set |
|
|
– Type of channel coding |
Reference to clause 6. 11.1a Parameter Set |
|
|
– Coding Rate |
Reference to clause 6. 11.1a Parameter Set |
|
|
– Rate matching attribute |
Reference to clause 6. 11.1a Parameter Set |
|
|
– CRC size |
Reference to clause 6. 11.1a Parameter Set |
|
|
– DCH quality target |
||
|
– BLER Quality value |
-20 (-2.0) |
|
|
All other IEs |
B1 |
Use the values defined in the RADIO BEARER SETUP message indicated as “Packet to CELL_DCH from CELL_DCH in PS” condition A3 except RB parameter set referred in 6.11.1b instead of 6.10 |
|
All other IEs |
B2 |
Use the values defined in the RADIO BEARER SETUP message indicated as “Packet to CELL_DCH from CELL_FACH in PS” condition A4 except RB parameter set referred in 6.11.1b instead of 6.10 |
|
All other IEs |
B3 |
Use the values defined in the RADIO BEARER SETUP message indicated as “Packet to CELL_DCH from CELL_DCH in PS” condition A3 except RB parameter set referred in 6.11.1a instead of 6.10 |
|
All other IEs |
B4 |
Use the values defined in the RADIO BEARER SETUP message indicated as “Packet to CELL_DCH from CELL_FACH in PS” condition A4 except RB parameter set referred in 6.11.1a instead of 6.10 |
|
Condition |
Explanation |
Version |
|
B1 |
This IE is needed for " MBMS PtP Radio Bearer Setup when UE state is state 6-7" |
|
|
B2 |
This IE is needed for " MBMS PtP Radio Bearer Setup when UE state is state 6-8" |
|
|
B3 |
This IE is needed for " MBMS PtP Radio Bearer Setup, when UE state is 6-10" |
|
|
B4 |
This IE is needed for " MBMS PtP Radio Bearer Setup, when UE state is 6-11" |
Contents of RADIO BEARER SETUP COMPLETE message: AM
|
Information Element |
Value/remark |
|
Message Type |
|
|
RRC transaction identifier |
Checked to see if the value is identical to the same IE in the downlink RADIO BEARER SETUP message. |
|
Integrity check info |
|
|
– Message authentication code |
This IE is checked to see if it is present. The value is compared against the XMAC-I value computed by SS. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
|
– RRC Message sequence number |
This IE is checked to see if it is present. The value is used by SS to compute the XMAC-I value. |
|
Uplink integrity protection activation info |
Not checked. |
|
CHOICE mode |
FDD |
|
START |
Not checked (if ciphering is OFF), check the presence if ciphering is ON. |
|
Deferred measurement control reading |
Not present for Rel-7 or later, otherwise Not checked |
|
COUNT-C activation time |
The UE shall include this IE if the following two conditions are fulfilled: (a) The RADIO BEARER SETUP message did not contain the IE "Ciphering activation time for DPCH" and (b) The RADIO BEARER SETUP message established the first RB(s) mapped to RLC-TM for a CN domain. Else, this IE is absent. |
|
Radio bearer uplink ciphering activation time info |
Not checked |
|
Uplink counter synchronization info |
Not present |
Contents of RADIO BEARER SETUP FAILURE message: AM
|
Information Element |
Value/remark |
|
Message Type |
|
|
RRC transaction identifier |
Checked to see if it is set to identical value of the same IE in the downlink RADIO BEARER SETUP message. |
|
Integrity check info |
|
|
– Message authentication code |
This IE is checked to see if it is present. The value is compared against the XMAC-I value computed by SS. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
|
– RRC Message sequence number |
This IE is checked to see if it is present. The value is used by SS to compute the XMAC-I value. |
|
Failure cause |
Checked to see if it meets test requirement |
|
Radio bearers for which reconfiguration would have succeeded |
Not checked |
Contents of RADIO BEARER RECONFIGURATION message: AM or UM
|
Information Element |
Condition |
Value/remark |
Version |
Index |
|||||
|---|---|---|---|---|---|---|---|---|---|
|
Message Type |
A1,A2,A3,A4,A5,A6 |
|
RBC-001 |
||||||
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
RBC-002 |
|||||||
|
Integrity check info |
|
RBC-003 |
|||||||
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
RBC-004 |
|||||||
|
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
RBC-005 |
|||||||
|
Integrity protection mode info |
Not Present |
RBC-006 |
|||||||
|
Ciphering mode info |
Not Present |
RBC-007 |
|||||||
|
Activation time |
A1,A2,A3 |
(256+CFN-(CFN MOD 8 + 8))MOD 256 |
RBC-008 |
||||||
|
Activation time |
A4, A5,A6 |
Not Present |
RBC-009 |
||||||
|
Delay restriction flag |
A1,A2,A3,A4,A5,A6 |
Not Present |
Rel-6 |
RBC-010 |
|||||
|
New U-RNTI |
Not Present |
RBC-011 |
|||||||
|
New C-RNTI |
A1, A2, A3, A4, |
Not Present |
RBC-012 |
||||||
|
New C-RNTI |
A5, A6 |
‘1010 1010 1010 1010’ |
RBC-013 |
||||||
|
New DSCH-RNTI |
A1, A2, A3, A4, A5, A6 |
Not Present |
R99 and Rel-4 only |
RBC-014 |
|||||
|
New H-RNTI |
A1, A2, A3, A4, A5, A6 |
Not Present |
Rel-5 |
RBC-015 |
|||||
|
New Primary E-RNTI |
Not Present |
Rel-6 |
RBC-016 |
||||||
|
New Secondary E-RNTI |
Not Present |
Rel-6 |
RBC-017 |
||||||
|
RRC State indicator |
A1, A2, A3, A4 |
CELL_DCH |
RBC-018 |
||||||
|
RRC State indicator |
A5, A6 |
CELL_FACH |
RBC-019 |
||||||
|
UE Mobility State Indicator |
Not Present |
Rel-7 |
RBC-020 |
||||||
|
UTRAN DRX cycle length coefficient |
A1,A2,A3,A4,A5,A6 |
Not Present |
|
RBC-021 |
|||||
|
CN information info |
Not Present |
|
RBC-022 |
||||||
|
URA identity |
Not Present |
|
RBC-023 |
||||||
|
CHOICE specification mode |
Complete specification |
Rel-5 |
RBC-024 |
||||||
|
RNC support for change of UE capability |
Not Present |
Rel-7 |
RBC-025 |
||||||
|
Reconfiguration in response to requested change of UE capability |
Not Present |
Rel-7 |
RBC-026 |
||||||
|
RAB information to reconfigure list |
Not Present |
RBC-027 |
|||||||
|
RB information to reconfigure list |
A1 |
TS25.331 specifies that "Although this IE is not always required, need is MP to align with ASN.1". |
RBC-028 |
||||||
|
– RB information to reconfigure |
(UM DCCH for RRC) |
RBC-029 |
|||||||
|
– RB identity |
1 |
RBC-030 |
|||||||
|
– PDCP info |
Not Present |
RBC-031 |
|||||||
|
– PDCP SN info |
Not Present |
RBC-032 |
|||||||
|
– RLC info |
Not Present |
RBC-033 |
|||||||
|
– RB mapping info |
Not Present |
RBC-034 |
|||||||
|
– RB stop/continue |
Not Present |
RBC-035 |
|||||||
|
– RB information to reconfigure |
(AM DCCH for RRC) |
RBC-036 |
|||||||
|
– RB identity |
2 |
RBC-037 |
|||||||
|
– PDCP info |
Not Present |
RBC-038 |
|||||||
|
– PDCP SN info |
Not Present |
RBC-039 |
|||||||
|
– RLC info |
Not Present |
RBC-040 |
|||||||
|
– RB mapping info |
Not Present |
RBC-041 |
|||||||
|
– RB stop/continue |
Not Present |
RBC-042 |
|||||||
|
– RB information to reconfigure |
(AM DCCH for NAS_DT High priority) |
RBC-043 |
|||||||
|
– RB identity |
3 |
RBC-044 |
|||||||
|
– PDCP info |
Not Present |
RBC-045 |
|||||||
|
– PDCP SN info |
Not Present |
RBC-046 |
|||||||
|
– RLC info |
Not Present |
RBC-047 |
|||||||
|
– RB mapping info |
Not Present |
RBC-048 |
|||||||
|
– RB stop/continue |
Not Present |
RBC-049 |
|||||||
|
– RB information to reconfigure |
(AM DCCH for NAS_DT Low priority) |
RBC-050 |
|||||||
|
– RB identity |
4 |
RBC-051 |
|||||||
|
– PDCP info |
Not Present |
RBC-052 |
|||||||
|
– PDCP SN info |
Not Present |
RBC-053 |
|||||||
|
– RLC info |
Not Present |
RBC-054 |
|||||||
|
– RB mapping info |
Not Present |
RBC-055 |
|||||||
|
– RB stop/continue |
Not Present |
RBC-056 |
|||||||
|
– RB information to reconfigure |
(TM DTCH) |
RBC-057 |
|||||||
|
– RB identity |
10 |
RBC-058 |
|||||||
|
– PDCP info |
Not Present |
RBC-059 |
|||||||
|
– PDCP SN info |
Not Present |
RBC-060 |
|||||||
|
– RLC info |
Not Present |
RBC-061 |
|||||||
|
– RB mapping info |
Not Present |
RBC-062 |
|||||||
|
– RB stop/continue |
Not Present |
RBC-063 |
|||||||
|
RB information to reconfigure list |
A2 |
TS25.331 specifies that "Although this IE is not always required, need is MP to align with ASN.1". |
RBC-064 |
||||||
|
– RB information to reconfigure |
(UM DCCH for RRC) |
RBC-065 |
|||||||
|
– RB identity |
1 |
RBC-066 |
|||||||
|
– PDCP info |
Not Present |
RBC-067 |
|||||||
|
– PDCP SN info |
Not Present |
RBC-068 |
|||||||
|
– RLC info |
Not Present |
RBC-069 |
|||||||
|
– RB mapping info |
Not Present |
RBC-070 |
|||||||
|
– RB stop/continue |
Not Present |
RBC-071 |
|||||||
|
– RB information to reconfigure |
(AM DCCH for RRC) |
RBC-072 |
|||||||
|
– RB identity |
2 |
RBC-073 |
|||||||
|
– PDCP info |
Not Present |
RBC-074 |
|||||||
|
– PDCP SN info |
Not Present |
RBC-075 |
|||||||
|
– RLC info |
Not Present |
RBC-076 |
|||||||
|
– RB mapping info |
Not Present |
RBC-077 |
|||||||
|
– RB stop/continue |
Not Present |
RBC-078 |
|||||||
|
– RB information to reconfigure |
(AM DCCH for NAS_DT High priority) |
RBC-079 |
|||||||
|
– RB identity |
3 |
RBC-080 |
|||||||
|
– PDCP info |
Not Present |
RBC-081 |
|||||||
|
– PDCP SN info |
Not Present |
RBC-082 |
|||||||
|
– RLC info |
Not Present |
RBC-083 |
|||||||
|
– RB mapping info |
Not Present |
RBC-084 |
|||||||
|
– RB stop/continue |
Not Present |
RBC-085 |
|||||||
|
– RB information to reconfigure |
(AM DCCH for NAS_DT Low priority) |
RBC-086 |
|||||||
|
– RB identity |
4 |
RBC-087 |
|||||||
|
– PDCP info |
Not Present |
RBC-088 |
|||||||
|
– PDCP SN info |
Not Present |
RBC-089 |
|||||||
|
– RLC info |
Not Present |
RBC-090 |
|||||||
|
– RB mapping info |
Not Present |
RBC-091 |
|||||||
|
– RB stop/continue |
Not Present |
RBC-092 |
|||||||
|
– RB information to reconfigure |
(TM DTCH) |
RBC-093 |
|||||||
|
– RB identity |
10 |
RBC-094 |
|||||||
|
– PDCP info |
Not Present |
RBC-095 |
|||||||
|
– PDCP SN info |
Not Present |
RBC-096 |
|||||||
|
– RLC info |
Not Present |
RBC-097 |
|||||||
|
– RB mapping info |
Not Present |
RBC-098 |
|||||||
|
– RB stop/continue |
Not Present |
RBC-099 |
|||||||
|
– RB information to reconfigure |
(TM DTCH) |
RBC-100 |
|||||||
|
– RB identity |
11 |
RBC-101 |
|||||||
|
– PDCP info |
Not Present |
RBC-102 |
|||||||
|
– PDCP SN info |
Not Present |
RBC-103 |
|||||||
|
– RLC info |
Not Present |
RBC-104 |
|||||||
|
– RB mapping info |
Not Present |
RBC-105 |
|||||||
|
– RB stop/continue |
Not Present |
RBC-106 |
|||||||
|
– RB information to reconfigure |
(TM DTCH) (This IE is needed for 12.2 kbps and 10.2 kbps) |
RBC-107 |
|||||||
|
– RB identity |
12 |
RBC-108 |
|||||||
|
– PDCP info |
Not Present |
RBC-109 |
|||||||
|
– PDCP SN info |
Not Present |
RBC-110 |
|||||||
|
– RLC info |
Not Present |
RBC-111 |
|||||||
|
– RB mapping info |
Not Present |
RBC-112 |
|||||||
|
– RB stop/continue |
Not Present |
RBC-113 |
|||||||
|
RB information to reconfigure list |
A3,A4,A5,A6 |
TS25.331 specifies that "Although this IE is not always required, need is MP to align with ASN.1". |
RBC-114 |
||||||
|
– RB information to reconfigure |
(UM DCCH for RRC) |
RBC-115 |
|||||||
|
– RB identity |
1 |
RBC-116 |
|||||||
|
– PDCP info |
Not Present |
RBC-117 |
|||||||
|
– PDCP SN info |
Not Present |
RBC-118 |
|||||||
|
– RLC info |
Not Present |
RBC-119 |
|||||||
|
– RB mapping info |
Not Present |
RBC-120 |
|||||||
|
– RB stop/continue |
Not Present |
RBC-121 |
|||||||
|
– RB information to reconfigure |
(AM DCCH for RRC) |
RBC-122 |
|||||||
|
– RB identity |
2 |
RBC-123 |
|||||||
|
– PDCP info |
Not Present |
RBC-124 |
|||||||
|
– PDCP SN info |
Not Present |
RBC-125 |
|||||||
|
– RLC info |
Not Present |
RBC-126 |
|||||||
|
– RB mapping info |
Not Present |
RBC-127 |
|||||||
|
– RB stop/continue |
Not Present |
RBC-128 |
|||||||
|
– RB information to reconfigure |
(AM DCCH for NAS_DT High priority) |
RBC-129 |
|||||||
|
– RB identity |
3 |
RBC-130 |
|||||||
|
– PDCP info |
Not Present |
RBC-131 |
|||||||
|
– PDCP SN info |
Not Present |
RBC-132 |
|||||||
|
– RLC info |
Not Present |
RBC-133 |
|||||||
|
– RB mapping info |
Not Present |
RBC-134 |
|||||||
|
– RB stop/continue |
Not Present |
RBC-135 |
|||||||
|
– RB information to reconfigure |
(AM DCCH for NAS_DT Low priority) |
RBC-136 |
|||||||
|
– RB identity |
4 |
RBC-137 |
|||||||
|
– PDCP info |
Not Present |
RBC-138 |
|||||||
|
– PDCP SN info |
Not Present |
RBC-139 |
|||||||
|
– RLC info |
Not Present |
RBC-140 |
|||||||
|
– RB mapping info |
Not Present |
RBC-141 |
|||||||
|
– RB stop/continue |
Not Present |
RBC-142 |
|||||||
|
– RB information to reconfigure |
(AM DTCH) |
RBC-143 |
|||||||
|
– RB identity |
20 |
RBC-144 |
|||||||
|
– PDCP info |
Not Present |
RBC-145 |
|||||||
|
– PDCP SN info |
Not Present |
RBC-146 |
|||||||
|
– RLC info |
Not Present |
RBC-147 |
|||||||
|
– RB mapping info |
Not Present |
RBC-148 |
|||||||
|
– RB stop/continue |
Not Present |
RBC-149 |
|||||||
|
RB information to be affected |
A1, A2, A3,A4,A5,A6 |
Not Present |
RBC-150 |
||||||
|
RB with PDCP context relocation info list |
Not Present |
Rel-5 |
RBC-151 |
||||||
|
PDCP ROHC target mode |
Not Present |
Rel-5 |
RBC-152 |
||||||
|
UL Transport channel information common for all transport channels |
A1, A2, A5,A6 |
Not Present |
RBC-153 |
||||||
|
UL Transport channel information common for all transport channels |
A3, A4 |
RBC-154 |
|||||||
|
– PRACH TFCS |
Not Present |
RBC-155 |
|||||||
|
– CHOICE mode |
FDD |
RBC-156 |
|||||||
|
– TFC subset |
Not Present |
RBC-157 |
|||||||
|
– UL DCH TFCS |
|
RBC-158 |
|||||||
|
– CHOICE TFCI signalling |
Normal |
RBC-159 |
|||||||
|
– TFCI Field 1 information |
|
RBC-160 |
|||||||
|
– CHOICE TFCS representation |
Complete reconfiguration |
RBC-161 |
|||||||
|
– TFCS complete reconfigure information |
|
RBC-162 |
|||||||
|
– CHOICE CTFC Size |
Number of bits used must be enough to cover all combinations of CTFC from clause 6.10.2.4 Parameter Set. |
RBC-163 |
|||||||
|
– CTFC information |
This IE is repeated for TFC numbers and reference to clause 6.10.2.4 Parameter Set |
RBC-164 |
|||||||
|
– CTFC |
Reference to clause 6.10.2.4 Parameter Set |
RBC-165 |
|||||||
|
– Power offset information |
|
RBC-166 |
|||||||
|
– CHOICE Gain Factors |
Computed Gain Factors(The last TFC is set to Signalled Gain Factors) |
RBC-167 |
|||||||
|
– Gain factor βc |
11 (below 64 kbps) 9 (equal or higher than 64 kbps) when HSDPA is not configured 9 (equal or higher than 64 kbps and below 384 kbps) when HSDPA is also configured 6 (equal or higher than 384 kbps) when HSDPA is also configured (Not Present if the CHOICE Gain Factors is set to ComputedGain Factors) |
RBC-168 |
|||||||
|
– Gain factor βd |
15 (Not Present if the CHOICE Gain Factors is set to ComputedGain Factors) |
RBC-169 |
|||||||
|
– Reference TFC ID |
0 |
RBC-170 |
|||||||
|
– CHOICE mode |
FDD |
RBC-171 |
|||||||
|
– Power offset P p-m |
Not Present |
RBC-172 |
|||||||
|
Deleted UL TrCH information |
A1, A2, A3, A4, A5,A6 |
Not Present |
RBC-173 |
||||||
|
Added or Reconfigured UL TrCH information |
A1, A2, A5,A6 |
Not Present |
RBC-174 |
||||||
|
Added or Reconfigured UL TrCH information |
A4 |
2 TrCHs(DCH for DCCH and DCH for DTCH) |
RBC-175 |
||||||
|
– Uplink transport channel type |
DCH |
RBC-176 |
|||||||
|
– UL Transport channel identity |
5 |
RBC-177 |
|||||||
|
– TFS |
RBC-178 |
||||||||
|
– CHOICE Transport channel type |
Dedicated transport channels |
RBC-179 |
|||||||
|
– Dynamic Transport format information |
RBC-180 |
||||||||
|
– RLC Size |
Reference to clause 6.10 Parameter Set |
RBC-181 |
|||||||
|
– Number of TBs and TTI List |
(This IE is repeated for TFI number.) |
RBC-182 |
|||||||
|
– Transmission Time Interval |
Not Present |
RBC-183 |
|||||||
|
– Number of Transport blocks |
Reference to clause 6.10 Parameter Set |
RBC-184 |
|||||||
|
– CHOICE Logical channel list |
All |
RBC-185 |
|||||||
|
– Semi-static Transport Format information |
RBC-186 |
||||||||
|
– Transmission time interval |
Reference to clause 6.10 Parameter Set |
RBC-187 |
|||||||
|
– Type of channel coding |
Reference to clause 6.10 Parameter Set |
RBC-188 |
|||||||
|
– Coding Rate |
Reference to clause 6.10 Parameter Set |
RBC-189 |
|||||||
|
– Rate matching attribute |
Reference to clause 6.10 Parameter Set |
RBC-190 |
|||||||
|
– CRC size |
Reference to clause 6.10 Parameter Set |
RBC-191 |
|||||||
|
– Uplink transport channel type |
DCH |
RBC-192 |
|||||||
|
– UL Transport channel identity |
1 |
RBC-193 |
|||||||
|
– TFS |
|
RBC-194 |
|||||||
|
– CHOICE Transport channel type |
Dedicated transport channels |
RBC-195 |
|||||||
|
– Dynamic Transport format information |
|
RBC-196 |
|||||||
|
– RLC Size |
Reference to clause 6.10 Parameter Set |
RBC-197 |
|||||||
|
– Number of TBs and TTI List |
(This IE is repeated for TFI number.) |
RBC-198 |
|||||||
|
– Transmission Time Interval |
Not Present |
RBC-199 |
|||||||
|
– Number of Transport blocks |
Reference to clause 6.10 Parameter Set |
RBC-200 |
|||||||
|
– CHOICE Logical channel list |
All |
RBC-201 |
|||||||
|
– Semi-static Transport Format information |
RBC-202 |
||||||||
|
– Transmission time interval |
Reference to clause 6.10 Parameter Set |
RBC-203 |
|||||||
|
– Type of channel coding |
Reference to clause 6.10 Parameter Set |
RBC-204 |
|||||||
|
– Coding Rate |
Reference to clause 6.10 Parameter Set |
RBC-205 |
|||||||
|
– Rate matching attribute |
Reference to clause 6.10 Parameter Set |
RBC-206 |
|||||||
|
– CRC size |
Reference to clause 6.10 Parameter Set |
RBC-207 |
|||||||
|
Added or Reconfigured UL TrCH information |
A3 |
(DCH for DTCH) |
RBC-208 |
||||||
|
– Uplink transport channel type |
DCH |
RBC-209 |
|||||||
|
– UL Transport channel identity |
1 |
RBC-210 |
|||||||
|
– TFS |
RBC-211 |
||||||||
|
– CHOICE Transport channel type |
Dedicated transport channels |
RBC-212 |
|||||||
|
– Dynamic Transport format information |
RBC-213 |
||||||||
|
– RLC Size |
Reference to clause 6.10 Parameter Set |
RBC-214 |
|||||||
|
– Number of TBs and TTI List |
(This IE is repeated for TFI number.) |
RBC-215 |
|||||||
|
– Transmission Time Interval |
Not Present |
RBC-216 |
|||||||
|
– Number of Transport blocks |
Reference to clause 6.10 Parameter Set |
RBC-217 |
|||||||
|
– CHOICE Logical channel list |
All |
RBC-218 |
|||||||
|
– Semi-static Transport Format information |
RBC-219 |
||||||||
|
– Transmission time interval |
Reference to clause 6.10 Parameter Set |
RBC-220 |
|||||||
|
– Type of channel coding |
Reference to clause 6.10 Parameter Set |
RBC-221 |
|||||||
|
– Coding Rate |
Reference to clause 6.10 Parameter Set |
RBC-222 |
|||||||
|
– Rate matching attribute |
Reference to clause 6.10 Parameter Set |
RBC-223 |
|||||||
|
– CRC size |
Reference to clause 6.10 Parameter Set |
RBC-224 |
|||||||
|
CHOICE mode |
A1,A2,A3,A4,A5,A6 |
Not Present |
RBC-225 |
||||||
|
DL Transport channel information common for all transport channel |
A1, A2, A5, A6 |
Not Present |
RBC-226 |
||||||
|
DL Transport channel information common for all transport channel |
A3,A4 |
RBC-227 |
|||||||
|
– SCCPCH TFCS |
Not Present |
RBC-228 |
|||||||
|
– CHOICE mode |
FDD |
RBC-229 |
|||||||
|
– CHOICE DL parameters |
Explicit |
RBC-230 |
|||||||
|
– DL DCH TFCS |
RBC-231 |
||||||||
|
– CHOICE TFCI Signalling |
Normal |
RBC-232 |
|||||||
|
– TFCI Field 1 Information |
RBC-233 |
||||||||
|
– CHOICE TFCS representation |
Complete reconfiguration |
RBC-234 |
|||||||
|
– TFCS complete reconfigure |
RBC-235 |
||||||||
|
– CHOICE CTFC Size |
Number of bits used must be enough to cover all combinations of CTFC from clause 6.10.2.4 Parameter Set. |
RBC-236 |
|||||||
|
– CTFC information |
This IE is repeated for TFC numbers and reference to clause 6.10.2.4 |
RBC-237 |
|||||||
|
– CTFC |
Reference to clause 6.10.2.4 Parameter Set |
RBC-238 |
|||||||
|
– Power offset information |
Not Present |
RBC-239 |
|||||||
|
Deleted DL TrCH information |
A1, A2, A3, A4, A5,A6 |
Not Present |
RBC-240 |
||||||
|
Added or Reconfigured DL TrCH information |
A1, A2, A5, A6 |
Not Present |
RBC-241 |
||||||
|
Added or Reconfigured DL TrCH information |
A4 |
2 TrCHs(DCH for DCCH and DCH for DTCH) |
RBC-242 |
||||||
|
– Downlink transport channel type |
DCH |
RBC-243 |
|||||||
|
– DL Transport channel identity |
10 |
RBC-244 |
|||||||
|
– CHOICE DL parameters |
Same as UL |
RBC-245 |
|||||||
|
– Uplink transport channel type |
DCH |
RBC-246 |
|||||||
|
– UL TrCH identity |
5 |
RBC-247 |
|||||||
|
– DCH quality target |
RBC-248 |
||||||||
|
– BLER Quality value |
Not Present |
RBC-249 |
|||||||
|
– Downlink transport channel type |
DCH |
RBC-250 |
|||||||
|
– DL Transport channel identity |
6 |
RBC-251 |
|||||||
|
– CHOICE DL parameters |
Explicit |
RBC-252 |
|||||||
|
– TFS |
RBC-253 |
||||||||
|
– CHOICE Transport channel type |
Dedicated transport channel |
RBC-254 |
|||||||
|
– Dynamic transport format information |
RBC-255 |
||||||||
|
– RLC Size |
Reference to clause 6.10 Parameter Set |
RBC-256 |
|||||||
|
– Number of TBs and TTI List |
(This IE is repeated for TFI number.) |
RBC-257 |
|||||||
|
– Dynamic transport format information |
RBC-258 |
||||||||
|
– Transmission Time Interval |
Not Present |
RBC-259 |
|||||||
|
– Number of Transport blocks |
Reference to clause 6.10 Parameter Set |
RBC-260 |
|||||||
|
– Semi-static Transport Format information |
RBC-261 |
||||||||
|
– Transmission time interval |
Reference to clause 6.10 Parameter Set |
RBC-262 |
|||||||
|
– Type of channel coding |
Reference to clause 6.10 Parameter Set |
RBC-263 |
|||||||
|
– Coding Rate |
Reference to clause 6.10 Parameter Set |
RBC-264 |
|||||||
|
– Rate matching attribute |
Reference to clause 6.10 Parameter Set |
RBC-265 |
|||||||
|
– CRC size |
Reference to clause 6.10 Parameter Set |
RBC-266 |
|||||||
|
– DCH quality target |
|
RBC-267 |
|||||||
|
– BLER Quality value |
-20 (-2.0) |
RBC-268 |
|||||||
|
Added or Reconfigured DL TrCH information |
A3 |
RBC-269 |
|||||||
|
– Downlink transport channel type |
DCH |
RBC-270 |
|||||||
|
– DL Transport channel identity |
6 |
RBC-271 |
|||||||
|
– CHOICE DL parameters |
Explicit |
RBC-272 |
|||||||
|
– TFS |
RBC-273 |
||||||||
|
– CHOICE Transport channel type |
Dedicated transport channel |
RBC-274 |
|||||||
|
– Dynamic transport format information |
RBC-275 |
||||||||
|
– RLC Size |
Reference to clause 6.10 Parameter Set |
RBC-276 |
|||||||
|
– Number of TBs and TTI List |
(This IE is repeated for TFI number.) |
RBC-277 |
|||||||
|
– Dynamic transport format information |
RBC-278 |
||||||||
|
– Transmission Time Interval |
Not Present |
RBC-279 |
|||||||
|
– Number of Transport blocks |
Reference to clause 6.10 Parameter Set |
RBC-280 |
|||||||
|
– Semi-static Transport Format information |
RBC-281 |
||||||||
|
– Transmission time interval |
Reference to clause 6.10 Parameter Set |
RBC-282 |
|||||||
|
– Type of channel coding |
Reference to clause 6.10 Parameter Set |
RBC-283 |
|||||||
|
– Coding Rate |
Reference to clause 6.10 Parameter Set |
RBC-284 |
|||||||
|
– Rate matching attribute |
Reference to clause 6.10 Parameter Set |
RBC-285 |
|||||||
|
– CRC size |
Reference to clause 6.10 Parameter Set |
RBC-286 |
|||||||
|
– DCH quality target |
RBC-287 |
||||||||
|
– BLER Quality value |
-20 (-2.0) |
RBC-288 |
|||||||
|
Preconfiguration |
A5 |
Not Present |
Rel-5 |
RBC-289 |
|||||
|
CHOICE Mode |
FDD |
RBC-290 |
|||||||
|
– predefinedConfiguration Identity |
Not Present |
RBC-291 |
|||||||
|
– defaultConfig |
Not Present |
RBC-292 |
|||||||
|
Frequency info |
A1,A2,A3,A4,A5 |
RBC-293 |
|||||||
|
– UARFCN uplink (Nu) |
Not present Absence of this IE is equivalent to applying the default duplex distance defined for the operating frequency according to 3GPP TS 25.101 [11] |
RBC-294 |
|||||||
|
– UARFCN downlink (Nd) |
Reference to clause 5.1 Test frequencies |
RBC-295 |
|||||||
|
Frequency info |
A6 |
Not Present |
RBC-296 |
||||||
|
DTX-DRX timing information |
Not Present |
Rel-7 |
RBC-297 |
||||||
|
DTX-DRX Information |
Not Present |
Rel-7 |
RBC-298 |
||||||
|
HS-SCCH less Information |
Not Present |
Rel-7 |
RBC-299 |
||||||
|
MIMO parameters |
Not Present |
Rel-7 |
RBC-300 |
||||||
|
CHOICE mode |
A5 |
Not Present |
Rel-8 |
RBC-301 |
|||||
|
– MIMO N_cqi_typeA/M_cqi ratio |
Not Present |
Rel-7 |
RBC-302 |
||||||
|
– MIMO pilot configuration |
Not Present |
Rel-7 |
RBC-303 |
||||||
|
– Precoding weight set restriction |
Not Present |
Rel-7 |
RBC-304 |
||||||
|
MIMO mode with four transmit antennas parameters |
Not Present |
Rel-11 |
RBC-304a |
||||||
|
DCH Enhancements info FDD |
Not Present |
Rel-12 |
RBC-304b |
||||||
|
Maximum allowed UL TX power |
A1,A2,A3,A4,A5,A6 |
33dBm |
RBC-305 |
||||||
|
CHOICE channel requirement |
A1, A2, A3, A4 |
Uplink DPCH info |
RBC-306 |
||||||
|
-Uplink DPCH power control info |
RBC-307 |
||||||||
|
– DPCCH power offset |
-40 (-80dB) |
RBC-308 |
|||||||
|
– PC Preamble |
1 frame |
RBC-309 |
|||||||
|
– SRB delay |
7 frames |
RBC-310 |
|||||||
|
– Power Control Algorithm |
Algorithm1 |
RBC-311 |
|||||||
|
– TPC step size |
0 (1dB) |
RBC-312 |
|||||||
|
– ACK |
Not Present |
Rel-5 |
RBC-313 |
||||||
|
– NACK |
Not Present |
Rel-5 |
RBC-314 |
||||||
|
– Ack-Nack repetition factor |
Not Present |
Rel-5 |
RBC-315 |
||||||
|
– Scrambling code type |
Long |
RBC-316 |
|||||||
|
– Scrambling code number |
0 (0 to 16777215) |
RBC-317 |
|||||||
|
– Number of DPDCH |
Not Present(1) |
RBC-318 |
|||||||
|
– spreading factor |
Reference to clause 6.10 Parameter Set |
RBC-319 |
|||||||
|
– TFCI existence |
Reference to clause 6.10 Parameter Set |
RBC-320 |
|||||||
|
– Number of FBI bit |
Reference to clause 6.10 Parameter Set |
RBC-321 |
|||||||
|
– Number of TPC bits |
Not Present |
Rel-7 |
RBC-322 |
||||||
|
– Puncturing Limit |
Reference to clause 6.10 Parameter Set |
RBC-323 |
|||||||
|
CHOICE channel requirement |
A5, A6 |
Not Present |
RBC-324 |
||||||
|
E-DCH Info |
Not Present |
Rel-6 |
RBC-325 |
||||||
|
Mac-es-e-resetIndicator |
A5 |
Not Present |
Rel-6 |
RBC-326 |
|||||
|
CHOICE modeSpecificInfo |
A5 |
FDD |
RBC-327 |
||||||
|
– e-DPCCH-Info |
A5 |
Not Present |
RBC-328 |
||||||
|
– schedulingTransmConfiguration |
A5 |
Not Present |
RBC-329 |
||||||
|
– ul-16QAM-Settings |
A5 |
Not Present |
Rel-7 |
RBC-330 |
|||||
|
CHOICE Mode |
A1,A2,A3,A4,A5,A6 |
FDD |
RBC-331 |
||||||
|
– Downlink PDSCH information |
Not Present |
R99 and Rel-4 only |
RBC-332 |
||||||
|
Uplink secondary cell info FDD |
A5 |
Rel-9 |
RBC-333 |
||||||
|
Uplink CLTD info FDD |
Not Present |
Rel-11 |
RBC-333a |
||||||
|
Uplink OLTD info FDD |
Not Present |
Rel-11 |
RBC-333b |
||||||
|
Downlink HS-PDSCH Information |
A1, A2, A3, A4, A5, A6 |
Not Present |
Rel-5 |
RBC-334 |
|||||
|
– Measurement Feedback Info |
A5 |
Not Present |
Rel-5 |
RBC-335 |
|||||
|
– Choice Mode |
A5 |
FDD |
RBC-336 |
||||||
|
– Downlink 64QAM configured |
A5 |
Not Present |
Rel-7 |
RBC-337 |
|||||
|
Downlink information common for all radio links |
A5, A6 |
Not Present |
RBC-338 |
||||||
|
Downlink information common for all radio links |
A1, A2, A3 |
RBC-339 |
|||||||
|
– Downlink DPCH info common for all RL |
RBC-340 |
||||||||
|
– Timing indicator |
Maintain |
RBC-341 |
|||||||
|
– CFN-targetSFN frame offset |
Not Present |
RBC-342 |
|||||||
|
– Downlink DPCH power control information |
RBC-343 |
||||||||
|
– DPC mode |
0 (single) |
RBC-344 |
|||||||
|
– CHOICE mode |
FDD |
RBC-345 |
|||||||
|
– Power offset PPilot-DPDCH |
0 |
RBC-346 |
|||||||
|
– DL rate matching restriction information |
Not Present |
RBC-347 |
|||||||
|
– Spreading factor |
Reference to clause 6.10 Parameter Set |
RBC-348 |
|||||||
|
– Fixed or Flexible Position |
Reference to clause 6.10 Parameter Set |
RBC-349 |
|||||||
|
– TFCI existence |
Reference to clause 6.10 Parameter Set |
RBC-350 |
|||||||
|
– CHOICE SF |
Reference to clause 6.10 Parameter Set |
RBC-351 |
|||||||
|
– DPCH compressed mode info |
Not Present |
RBC-352 |
|||||||
|
– TX Diversity mode |
None |
RBC-353 |
|||||||
|
– SSDT information |
Not Present |
R99 and Rel-4 only |
RBC-354 |
||||||
|
– Default DPCH Offset Value |
Not Present |
RBC-355 |
|||||||
|
– MAC-hs reset indicator |
Not Present |
Rel-5 |
RBC-356 |
||||||
|
Downlink information common for all radio links |
A4 |
RBC-357 |
|||||||
|
– Downlink DPCH info common for all RL |
RBC-358 |
||||||||
|
– Timing indicator |
Initialize |
RBC-359 |
|||||||
|
– CFN-targetSFN frame offset |
Not Present |
RBC-360 |
|||||||
|
– Downlink DPCH power control information |
RBC-361 |
||||||||
|
– DPC mode |
0 (single) |
RBC-362 |
|||||||
|
– CHOICE mode |
FDD |
RBC-363 |
|||||||
|
– Power offset PPilot-DPDCH |
0 |
RBC-364 |
|||||||
|
– DL rate matching restriction information |
Not Present |
RBC-365 |
|||||||
|
– Spreading factor |
Reference to clause 6.10 Parameter Set |
RBC-366 |
|||||||
|
– Fixed or Flexible Position |
Reference to clause 6.10 Parameter Set |
RBC-367 |
|||||||
|
– TFCI existence |
Reference to clause 6.10 Parameter Set |
RBC-368 |
|||||||
|
– CHOICE SF |
Reference to clause 6.10 Parameter Set |
RBC-369 |
|||||||
|
– DPCH compressed mode info |
Not Present |
RBC-370 |
|||||||
|
– TX Diversity mode |
None |
RBC-371 |
|||||||
|
– SSDT information |
Not Present |
R99 and Rel-4 only |
RBC-372 |
||||||
|
– Default DPCH Offset Value |
Present Arbitrary set to value 0..306688 by step of 512 |
RBC-373 |
|||||||
|
– MAC-hs reset indicator |
Not Present |
Rel-5 |
RBC-374 |
||||||
|
Downlink information per radio link list |
A1, A2, A3 |
RBC-375 |
|||||||
|
-Downlink information for each radio link |
RBC-376 |
||||||||
|
– Choice mode |
FDD |
RBC-377 |
|||||||
|
– Primary CPICH info |
|
RBC-378 |
|||||||
|
– Primary scrambling code |
Ref. to the Default setting in clause 6.1 (FDD) |
RBC-379 |
|||||||
|
– PDSCH with SHO DCH info |
Not Present |
R99 and Rel-4 only |
RBC-380 |
||||||
|
– PDSCH code mapping |
Not Present |
R99 and Rel-4 only |
RBC-381 |
||||||
|
– Serving HS-DSCH radio link indicator |
FALSE |
Rel-5 |
RBC-382 |
||||||
|
– Serving E-DCH radio link indicator |
FALSE |
Rel-6 |
RBC-383 |
||||||
|
– Downlink DPCH info for each RL |
|
RBC-384 |
|||||||
|
– Primary CPICH usage for channel estimation |
Primary CPICH may be used |
RBC-385 |
|||||||
|
– DPCH frame offset |
Set to value Default DPCH Offset Value (as currently stored in SS) mod 38 400 |
RBC-386 |
|||||||
|
– Secondary CPICH info |
Not Present |
RBC-387 |
|||||||
|
– Secondary scrambling code |
RBC-388 |
||||||||
|
– channelisation code |
RBC-389 |
||||||||
|
– DL channelisation code |
RBC-390 |
||||||||
|
– Secondary scrambling code |
2 |
RBC-391 |
|||||||
|
– Spreading factor |
Reference to clause 6.10 Parameter Set |
RBC-392 |
|||||||
|
– Code number |
0 |
RBC-393 |
|||||||
|
– Scrambling code change |
Set to value Default1: No code change (if the UE has a compressed mode pattern sequence configured in variable TGPS_IDENTITY or included in the message including IE "Downlink DPCH info for each RL", which is using compressed mode method "SF/2") Set to value Default2: OMIT (otherwise) |
RBC-394 |
|||||||
|
– TPC combination index |
0 |
RBC-395 |
|||||||
|
– SSDT Cell Identity |
Not Present |
R99 and Rel-4 only |
RBC-396 |
||||||
|
– Closed loop timing adjustment mode |
Not Present |
RBC-397 |
|||||||
|
– E-AGCH Info |
Not present |
Rel-6 |
RBC-398 |
||||||
|
– E-HICH Information |
Not present |
Rel-6 |
RBC-399 |
||||||
|
– E-RGCH Information |
Not present |
Rel-6 |
RBC-400 |
||||||
|
– SCCPCH information for FACH |
Not Present |
R99 and Rel-4 only |
RBC-401 |
||||||
|
Downlink information per radio link list |
A4 |
RBC-402 |
|||||||
|
-Downlink information for each radio link |
RBC-403 |
||||||||
|
– Choice mode |
FDD |
RBC-404 |
|||||||
|
– Primary CPICH info |
RBC-405 |
||||||||
|
– Primary scrambling code |
Ref. to the Default setting in clause 6.1 (FDD) |
RBC-406 |
|||||||
|
– PDSCH with SHO DCH info |
Not Present |
R99 and Rel-4 only |
RBC-407 |
||||||
|
– PDSCH code mapping |
Not Present |
R99 and Rel-4 only |
RBC-408 |
||||||
|
– Serving HS-DSCH radio link indicator |
FALSE |
Rel-5 |
RBC-409 |
||||||
|
– Serving E-DCH radio link indicator |
FALSE |
Rel-6 |
RBC-410 |
||||||
|
– Downlink DPCH info for each RL |
RBC-411 |
||||||||
|
– Primary CPICH usage for channel estimation |
Primary CPICH may be used |
RBC-412 |
|||||||
|
– DPCH frame offset |
Set to value : Default DPCH Offset Value mod 38 400 |
RBC-413 |
|||||||
|
– Secondary CPICH info |
Not Present |
RBC-414 |
|||||||
|
– Secondary scrambling code |
RBC-415 |
||||||||
|
– channelisation code |
RBC-416 |
||||||||
|
– DL channelisation code |
RBC-417 |
||||||||
|
– Secondary scrambling code |
2 |
RBC-418 |
|||||||
|
– Spreading factor |
Reference to clause 6.10 Parameter Set |
RBC-419 |
|||||||
|
– Code number |
0 |
RBC-420 |
|||||||
|
– Scrambling code change |
Set to value Default1: No code change (if the UE has a compressed mode pattern sequence configured in variable TGPS_IDENTITY or included in the message including IE "Downlink DPCH info for each RL", which is using compressed mode method "SF/2") Set to value Default2: OMIT (otherwise) |
RBC-421 |
|||||||
|
– TPC combination index |
0 |
RBC-422 |
|||||||
|
– SSDT Cell Identity |
Not Present |
R99 and Rel-4 only |
RBC-423 |
||||||
|
– Closed loop timing adjustment mode |
Not Present |
RBC-424 |
|||||||
|
– E-AGCH Info |
Not present |
Rel-6 |
RBC-425 |
||||||
|
– E-HICH Information |
Not present |
Rel-6 |
RBC-426 |
||||||
|
– E-RGCH Information |
Not present |
Rel-6 |
RBC-427 |
||||||
|
– SCCPCH information for FACH |
Not Present |
R99 and Rel-4 only |
RBC-428 |
||||||
|
– Downlink information for each radio link |
A5 |
RBC-429 |
|||||||
|
– Choice mode |
FDD |
RBC-430 |
|||||||
|
– Primary CPICH info |
RBC-431 |
||||||||
|
– Primary scrambling code |
Ref. to the Default setting in clause 6.1 (FDD) |
RBC-432 |
|||||||
|
– PDSCH with SHO DCH info |
Not Present |
R99 and Rel-4 only |
RBC-433 |
||||||
|
– PDSCH code mapping |
Not Present |
R99 and Rel-4 only |
RBC-434 |
||||||
|
– Serving HS-DSCH radio link indicator |
FALSE |
Rel-5 |
RBC-435 |
||||||
|
– Serving E-DCH radio link indicator |
FALSE |
Rel-6 |
RBC-436 |
||||||
|
– Downlink DPCH info for each RL |
Not present |
RBC-437 |
|||||||
|
– E-AGCH Info |
Not present |
Rel-6 |
RBC-438 |
||||||
|
– E-HICH Information |
Not present |
Rel-6 |
RBC-439 |
||||||
|
– E-RGCH Information |
Not present |
Rel-6 |
RBC-440 |
||||||
|
– SCCPCH Information for FACH |
Not Present |
R99 and Rel-4 only |
RBC-441 |
||||||
|
– Downlink information for each radio link |
A6 |
R99 |
RBC-442 |
||||||
|
– Choice mode |
FDD |
RBC-443 |
|||||||
|
– Primary CPICH info |
RBC-444 |
||||||||
|
– Primary scrambling code |
Ref. to the Default setting in clause 6.1 (FDD) |
RBC-445 |
|||||||
|
– PDSCH with SHO DCH info |
Not Present |
R99 and Rel-4 only |
RBC-446 |
||||||
|
– PDSCH code mapping |
Not Present |
R99 and Rel-4 only |
RBC-447 |
||||||
|
– Serving E-DCH radio link indicator |
FALSE |
Rel-6 |
RBC-448 |
||||||
|
– Downlink DPCH info for each RL |
Not present |
RBC-449 |
|||||||
|
– E-AGCH Info |
Not present |
Rel-6 |
RBC-450 |
||||||
|
– E-HICH Information |
Not present |
Rel-6 |
RBC-451 |
||||||
|
– E-RGCH Information |
Not present |
Rel-6 |
RBC-452 |
||||||
|
– SCCPCH Information for FACH |
Not Present |
R99 and Rel-4 only |
RBC-453 |
||||||
|
– Downlink information for each radio link |
A6 |
Not Present |
Rel-4 only |
RBC-454 |
|||||
|
Downlink secondary cell info FDD |
A5 |
Not Present |
Rel-8 |
RBC-455 |
|||||
|
Additional downlink secondary cell info list FDD |
A5 |
Not Present |
Rel-10 |
RBC-456 |
|||||
|
– Downlink secondary cell info FDD |
A5 |
Not Present |
Rel-10 |
RBC-457 |
|||||
|
Additional downlink secondary cell info list FDD 2 – Downlink secondary cell info FDD 2 |
A5 A5 |
Not Present Not Present |
Rel-11 Rel-11 |
RBC-457a |
|||||
|
MBMS PL Service Restriction Information |
A1,A2,A3,A4,A5,A6 |
Not Present |
Rel-6 |
RBC-458 |
|||||
|
Condition |
Explanation |
|
A1 |
This IE need for "Non speech in CS" |
|
A2 |
This IE need for "Speech in CS" |
|
A3 |
This IE need for "Packet to CELL_DCH from CELL_DCH in PS" |
|
A4 |
This IE need for "Packet to CELL_DCH from CELL_FACH in PS" |
|
A5 |
This IE need for "Packet to CELL_FACH from CELL_DCH in PS" |
|
A6 |
This IE need for "Packet to CELL_FACH from CELL_FACH in PS" |
Contents of RADIO BEARER RECONFIGURATION FAILURE message: AM
|
Information Element |
Value/remark |
|
Message Type |
|
|
RRC transaction identifier |
Checked to see if it is set to identical value of the same IE in the downlink RADIO BEARER RECONFIGURATION message. |
|
Integrity check info |
|
|
– Message authentication code |
This IE is checked to see if it is present. The value is compared against the XMAC-I value computed by SS. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
|
– RRC Message sequence number |
This IE is checked to see if it is present. The value is used by SS to compute the XMAC-I value. |
|
Failure cause |
Checked to see if it meets test requirement |
|
Radio bearers for which reconfiguration would have succeeded List |
Not checked |
Contents of RADIO BEARER RECONFIGURATION COMPLETE message: AM
|
Information Element |
Value/remark |
|
Message Type |
|
|
RRC transaction identifier |
Checked to see if the value is identical to the same IE in the downlink RADIO BEARER RECONFIGURATION COMPLETE message |
|
Integrity check info |
|
|
– Message authentication code |
This IE is checked to see if it is present. The value is compared against the XMAC-I value computed by SS. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
|
– RRC Message sequence number |
This IE is checked to see if it is present. The value is used by SS to compute the XMAC-I value. |
|
Uplink integrity protection activation info |
Not checked |
|
CHOICE mode |
FDD |
|
Deferred measurement control reading |
Not present for Rel-7 or later, otherwise Not checked |
|
COUNT-C activation time |
Not checked |
|
Radio bearer uplink ciphering activation time info |
Not checked |
|
Uplink counter synchronization info |
Not present |
Contents of RADIO BEARER RELEASE message: AM or UM
|
Information Element |
Condition |
Value/remark |
Version |
Index |
|---|---|---|---|---|
|
Message Type |
A1, A2, A3, A4, A5, A6, A7, A8 |
RBR-001 |
||
|
, A9, A10 |
Rel-5 |
RBR-002 |
||
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
RBR-003 |
||
|
Integrity check info |
RBR-004 |
|||
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
RBR-005 |
||
|
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
RBR-006 |
||
|
Integrity protection mode info |
Not Present |
RBR-007 |
||
|
Ciphering mode info |
Not Present |
RBR-008 |
||
|
Activation time |
A1, A2, A3, A7, A8 |
(256+CFN-(CFN MOD 8 + 8))MOD 256 |
RBR-009 |
|
|
, A9, A10 |
Rel-5 |
RBR-010 |
||
|
Activation time |
A4, A5, A6 |
Not Present |
RBR-011 |
|
|
New U-RNTI |
Not Present |
RBR-012 |
||
|
New C-RNTI |
A1,A2,A3,A4 |
Not Present |
RBR-013 |
|
|
, A9 |
Rel-5 |
RBR-014 |
||
|
New C-RNTI |
A5, A6, A7, A8 |
‘1010 1010 1010 1010’ |
RBR-015 |
|
|
, A10 |
Rel-5 |
RBR-016 |
||
|
New DSCH-RNTI |
A1, A2, A3, A4, A5, A6, A7, A8 |
Not Present |
R99 and Rel-4 only |
RBR-017 |
|
New H-RNTI |
A1, A2, A3, A4, A5, A6, A7, A8 |
Not Present |
RBR-018 |
|
|
, A9, A10, |
Rel-5 |
RBR-019 |
||
|
New Primary E-RNTI |
Not Present |
Rel-6 |
RBR-020 |
|
|
New Secondary E-RNTI |
Not Present |
Rel-6 |
RBR-021 |
|
|
RRC State indicator |
A1,A2, A3, A4 |
CELL_DCH |
RBR-022 |
|
|
, A9 |
Rel-5 |
RBR-023 |
||
|
RRC State indicator |
A5, A6, A7, A8 |
CELL_FACH |
RBR-024 |
|
|
, A10 |
Rel-5 |
RBR-025 |
||
|
UE Mobility State Indicator |
Not Present |
Rel-7 |
RBR-026 |
|
|
UTRAN DRX cycle length coefficient |
A1,A2,A3,A4,A5,A6, A7, A8 |
Not Present |
RBR-027 |
|
|
, A9, A10 |
Rel-5 |
RBR-028 |
||
|
CN information info |
Not Present |
RBR-029 |
||
|
Signalling Connection release indication |
Not Present |
RBR-030 |
||
|
URA identity |
Not Present |
RBR-031 |
||
|
RNC support for change of UE capability |
Not Present |
Rel-7 |
RBR-032 |
|
|
RAB information to reconfigure list |
Not Present |
RBR-033 |
||
|
RB information to release |
A1,A2, A7, A8 |
RBR-034 |
||
|
– RB identity |
10 |
RBR-035 |
||
|
RB information to release |
A2, A8 |
RBR-036 |
||
|
– RB identity |
11 |
RBR-037 |
||
|
RB information to release |
A2, A8 |
RBR-038 |
||
|
– RB identity |
12 |
RBR-039 |
||
|
RB information to release |
A3, A4, A5, A6 |
RBR-040 |
||
|
– RB identity |
20 |
RBR-041 |
||
|
RB information to release |
A9, A10 |
Rel-5 |
RBR-042 |
|
|
– RB identity |
25 |
RBR-043 |
||
|
RB information to reconfigure list |
A1,A2, A3,A4,A5, A6, A7, A8, A9, A10 |
Not Present |
Rel-6 |
RBR-044 |
|
RB information to be affected |
A1,A2, A3,A4,A5, A6, A7, A8 |
Not Present |
RBR-045 |
|
|
, A9, A10 |
Rel-5 |
RBR-046 |
||
|
Downlink counter synchronization info |
A1,A2,A3,A4,A5,A6, A7, A8 |
Not Present |
RBR-047 |
|
|
, A9, A10 |
Rel-5 |
RBR-048 |
||
|
UL Transport channel information for all transport channels |
A1, A2, A3, A4, A5, A6, A7, A8 |
TFCS reconfigured to fit the new transport channel configuration. |
RBR-049 |
|
|
, A9, A10 |
Rel-5 |
RBR-050 |
||
|
Deleted UL TrCH Information |
A1,A2, A3, A4, A5, A6, A7, A8 |
RBR-051 |
||
|
, A9, A10 |
Rel-5 |
RBR-052 |
||
|
– Uplink transport channel type |
DCH |
RBR-053 |
||
|
– Transport channel identity |
1 |
RBR-054 |
||
|
Deleted UL TrCH Information |
A2, A8 |
RBR-055 |
||
|
– Uplink transport channel type |
DCH |
RBR-056 |
||
|
– Transport channel identity |
2 |
RBR-057 |
||
|
Deleted UL TrCH Information |
A2, A8 |
RBR-058 |
||
|
– Uplink transport channel type |
DCH |
RBR-059 |
||
|
– Transport channel identity |
3 |
RBR-060 |
||
|
Added or Reconfigured UL TrCH information |
A5, A6, A7, A8 |
Not Present |
RBR-061 |
|
|
, A10 |
Rel-5 |
RBR-062 |
||
|
Added or Reconfigured UL TrCH information |
A1, A2, A3, A4 |
TrCHs(DCH for DCCH ) |
RBR-063 |
|
|
, A9 |
Rel-5 |
RBR-064 |
||
|
– Uplink transport channel type |
DCH |
RBR-065 |
||
|
– UL Transport channel identity |
5 |
RBR-066 |
||
|
– TFS |
RBR-067 |
|||
|
– CHOICE Transport channel type |
Dedicated transport channels |
RBR-068 |
||
|
– Dynamic Transport format information |
RBR-069 |
|||
|
– RLC Size |
According to clause 6.10.2.4.1.3 (standalone 13.6 kbps signalling radio bearer) |
RBR-070 |
||
|
– Number of TBs and TTI List |
(This IE is repeated for TFI number.) |
RBR-071 |
||
|
– Transmission Time Interval |
According to clause 6.10.2.4.1.3 (standalone 13.6 kbps signalling radio bearer) |
RBR-072 |
||
|
– Number of Transport blocks |
According to clause 6.10.2.4.1.3 (standalone 13.6 kbps signalling radio bearer) |
RBR-073 |
||
|
– CHOICE Logical channel list |
All |
RBR-074 |
||
|
– Semi-static Transport Format information |
RBR-075 |
|||
|
– Transmission time interval |
According to clause 6.10.2.4.1.3 (standalone 13.6 kbps signalling radio bearer) |
RBR-076 |
||
|
– Type of channel coding |
According to clause 6.10.2.4.1.3 (standalone 13.6 kbps signalling radio bearer) |
RBR-077 |
||
|
– Coding Rate |
According to clause 6.10.2.4.1.3 (standalone 13.6 kbps signalling radio bearer) |
RBR-078 |
||
|
– Rate matching attribute |
According to clause 6.10.2.4.1.3 (standalone 13.6 kbps signalling radio bearer) |
RBR-079 |
||
|
– CRC size |
According to clause 6.10.2.4.1.3 (standalone 13.6 kbps signalling radio bearer) |
RBR-080 |
||
|
DL Transport channel information for all transport channels |
A1, A2, A3, A4, A5, A6, A7, A8 |
TFCS reconfigured to fit the new transport channel configuration. |
RBR-081 |
|
|
, A9, A10 |
Rel-5 |
RBR-082 |
||
|
Deleted DL TrCH Information |
A1, A2, A3, A4, A5, A6, A7, A8 |
RBR-083 |
||
|
, A9 |
Rel-5 |
RBR-084 |
||
|
– Downlink transport channel type |
DCH |
RBR-085 |
||
|
– Transport channel identity |
6 |
RBR-086 |
||
|
Deleted DL TrCH Information |
A2, A8 |
RBR-087 |
||
|
– Downlink transport channel type |
DCH |
RBR-088 |
||
|
– Transport channel identity |
7 |
RBR-089 |
||
|
Deleted DL TrCH Information |
A2, A8 |
RBR-090 |
||
|
– Downlink transport channel type |
DCH |
RBR-091 |
||
|
– Transport channel identity |
8 |
RBR-092 |
||
|
Deleted DL TrCH Information |
A9, A10 |
Rel-5 |
RBR-093 |
|
|
– Downlink transport channel type |
HS-DSCH |
RBR-094 |
||
|
– DL HS-DSCH MAC-d flow identity |
0 |
RBR-095 |
||
|
Added or Reconfigured DL TrCH information |
A5, A6, A7, A8 |
Not Present |
RBR-096 |
|
|
, A10 |
Rel-5 |
RBR-097 |
||
|
Added or Reconfigured DL TrCH information |
A1, A2, A3, A4 |
1 TrCHs(DCH for DCCH) |
RBR-098 |
|
|
, A9 |
Rel-5 |
RBR-099 |
||
|
– Downlink transport channel type |
DCH |
RBR-100 |
||
|
– DL Transport channel identity |
10 |
RBR-101 |
||
|
– CHOICE DL parameters |
Same as UL |
RBR-102 |
||
|
– Uplink transport channel type |
DCH |
RBR-103 |
||
|
– UL TrCH identity |
5 |
RBR-104 |
||
|
– DCH quality target |
RBR-105 |
|||
|
– BLER Quality value |
Not Present |
RBR-106 |
||
|
Frequency info |
A1,A2,A3,A4,A5, A7, A8 |
RBR-107 |
||
|
, A9, A10 |
Rel-5 |
RBR-108 |
||
|
– UARFCN uplink (Nu) |
Not present Absence of this IE is equivalent to applying the default duplex distance defined for the operating frequency according to 3GPP TS 25.101 [11] |
RBR-109 |
||
|
– UARFCN downlink (Nd) |
Reference to clause 5.1 Test frequencies |
RBR-110 |
||
|
DTX-DRX timing information |
Not Present |
Rel-7 |
RBR-111 |
|
|
DTX-DRX Information |
Not Present |
Rel-7 |
RBR-112 |
|
|
HS-SCCH less Information |
Not Present |
Rel-7 |
RBR-113 |
|
|
MIMO parameters |
Not Present |
Rel-7 |
RBR-114 |
|
|
Maximum allowed UL TX power |
33dBm |
RBR-115 |
||
|
Frequency info |
A6 |
Not Present |
RBR-116 |
|
|
CHOICE channel requirement |
A5, A6, A7, A8 |
Not Present |
RBR-117 |
|
|
, A10 |
Rel-5 |
RBR-118 |
||
|
CHOICE channel requirement |
A1, A2, A3, A4 |
Uplink DPCH info |
RBR-119 |
|
|
, A9 |
Rel-5 |
RBR-120 |
||
|
– Uplink DPCH power control info |
RBR-121 |
|||
|
– DPCCH power offset |
-40 (-80dB) |
RBR-122 |
||
|
– PC Preamble |
1 frame |
RBR-123 |
||
|
– SRB delay |
7 frames |
RBR-124 |
||
|
– Power Control Algorithm |
Algorithm1 |
RBR-125 |
||
|
– ACK |
Not Present |
Rel-5 |
RBR-126 |
|
|
– NACK |
Not Present |
Rel-5 |
RBR-127 |
|
|
– Ack-Nack repetition factor |
Not Present |
Rel-5 |
RBR-128 |
|
|
– TPC step size |
0 (1dB) |
RBR-129 |
||
|
– Scrambling code type |
Long |
RBR-130 |
||
|
– Scrambling code number |
0 (0 to 16777215) |
RBR-131 |
||
|
– Number of DPDCH |
Not Present(1) |
RBR-132 |
||
|
– spreading factor |
Reference to clause 6.10 Parameter Set |
RBR-133 |
||
|
– TFCI existence |
Reference to clause 6.10 Parameter Set |
RBR-134 |
||
|
– Number of FBI bit |
Reference to clause 6.10 Parameter Set |
RBR-135 |
||
|
– Number of TPC bits |
Not Present |
Rel-7 |
RBR-136 |
|
|
– Puncturing Limit |
Reference to clause 6.10 Parameter Set |
RBR-137 |
||
|
E-DCH Info |
Not Present |
Rel-6 |
RBR-138 |
|
|
CHOICE Mode |
A1,A2,A3,A4,A5,A6, A7, A8 |
FDD |
RBR-139 |
|
|
, A9, A10 |
Rel-5 |
RBR-140 |
||
|
– Downlink PDSCH information |
Not Present |
R99 and Rel-4 only |
RBR-141 |
|
|
Downlink HS-PDSCH Information |
A1, A2, A3, A4, A5, A6, A7, A8, A9, A10 |
Not Present |
Rel-5 |
RBR-142 |
|
Downlink information common for all radio links |
A5, A6, A7, A8 |
Not Present |
RBR-143 |
|
|
, A10 |
Rel-5 |
RBR-144 |
||
|
Downlink information common for all radio links |
A1,A2, A3 |
RBR-145 |
||
|
, A9 |
Rel-5 |
RBR-146 |
||
|
– Downlink DPCH info common for all RL |
RBR-147 |
|||
|
– Timing indicator |
Maintain |
RBR-148 |
||
|
– CFN-targetSFN frame offset |
Not Present |
RBR-149 |
||
|
– Downlink DPCH power control information |
RBR-150 |
|||
|
– DPC mode |
0 (single) |
RBR-151 |
||
|
– CHOICE mode |
FDD |
RBR-152 |
||
|
– Power offset PPilot-DPDCH |
0 |
RBR-153 |
||
|
– DL rate matching restriction information |
Not Present |
RBR-154 |
||
|
– Spreading factor |
Reference to clause 6.10 Parameter Set |
RBR-155 |
||
|
– Fixed or Flexible Position |
Reference to clause 6.10 Parameter Set |
RBR-156 |
||
|
– TFCI existence |
Reference to clause 6.10 Parameter Set |
RBR-157 |
||
|
– CHOICE SF |
Reference to clause 6.10 Parameter Set |
RBR-158 |
||
|
– DPCH compressed mode info |
Not Present |
RBR-159 |
||
|
– TX Diversity mode |
None |
RBR-160 |
||
|
– SSDT information |
Not Present |
R99 and Rel-4 only |
RBR-161 |
|
|
– Default DPCH Offset Value |
Not Present |
RBR-162 |
||
|
– MAC-hs reset indicator |
Not Present |
Rel-5 |
RBR-163 |
|
|
Downlink information common for all radio links |
A4 |
RBR-164 |
||
|
– Downlink DPCH info common for all RL |
RBR-165 |
|||
|
– Timing indicator |
Initialize |
RBR-166 |
||
|
– CFN-targetSFN frame offset |
Not Present |
RBR-167 |
||
|
– Downlink DPCH power control information |
RBR-168 |
|||
|
– DPC mode |
0 (single) |
RBR-169 |
||
|
– CHOICE mode |
FDD |
RBR-170 |
||
|
– Power offset PPilot-DPDCH |
0 |
RBR-171 |
||
|
– DL rate matching restriction information |
Not Present |
RBR-172 |
||
|
– Spreading factor |
Reference to clause 6.10 Parameter Set |
RBR-173 |
||
|
– Fixed or Flexible Position |
Reference to clause 6.10 Parameter Set |
RBR-174 |
||
|
– TFCI existence |
Reference to clause 6.10 Parameter Set |
RBR-175 |
||
|
– CHOICE SF |
Reference to clause 6.10 Parameter Set |
RBR-176 |
||
|
– DPCH compressed mode info |
Not Present |
RBR-177 |
||
|
– TX Diversity mode |
None |
RBR-178 |
||
|
– SSDT information |
Not Present |
R99 and Rel-4 only |
RBR-179 |
|
|
– Default DPCH Offset Value |
Arbitrary set to value 0..306688 by step of 512 |
RBR-180 |
||
|
– MAC-hs reset indicator |
Not Present |
Rel-5 |
RBR-181 |
|
|
Downlink information for each radio link list |
A1,A2,A3 |
RBR-182 |
||
|
, A9 |
Rel-5 |
RBR-183 |
||
|
-Downlink information for each radio link |
RBR-184 |
|||
|
– Choice mode |
FDD |
RBR-185 |
||
|
– Primary CPICH info |
RBR-186 |
|||
|
– Primary scrambling code |
Ref. to the Default setting in clause 6.1 (FDD) |
RBR-187 |
||
|
– PDSCH with SHO DCH info |
Not Present |
R99 and Rel-4 only |
RBR-188 |
|
|
– PDSCH code mapping |
Not Present |
R99 and Rel-4 only |
RBR-189 |
|
|
– Serving HS-DSCH radio link indicator |
FALSE |
Rel-5 |
RBR-190 |
|
|
– Serving E-DCH radio link indicator |
FALSE |
Rel-6 |
RBR-191 |
|
|
– Downlink DPCH info for each RL |
RBR-192 |
|||
|
– Primary CPICH usage for channel estimation |
Primary CPICH may be used |
RBR-193 |
||
|
– DPCH frame offset |
Set to value Default DPCH Offset Value (as currently stored in SS) mod 38 400 |
RBR-194 |
||
|
– Secondary CPICH info |
Not Present |
RBR-195 |
||
|
– Secondary scrambling code |
RBR-196 |
|||
|
– channelisation code |
RBR-197 |
|||
|
– DL channelisation code |
RBR-198 |
|||
|
– Secondary scrambling code |
3 |
RBR-199 |
||
|
– Spreading factor |
Reference to clause 6.10 Parameter Set |
RBR-200 |
||
|
– Code number |
0 |
RBR-201 |
||
|
– Scrambling code change |
Set to value Default1: No code change (if the UE has a compressed mode pattern sequence configured in variable TGPS_IDENTITY or included in the message including IE "Downlink DPCH info for each RL", which is using compressed mode method "SF/2") Set to value Default2: OMIT (otherwise) |
RBR-202 |
||
|
– TPC combination index |
0 |
RBR-203 |
||
|
– SSDT Cell Identity |
Not Present |
R99 and Rel-4 only |
RBR-204 |
|
|
– Closed loop timing adjustment mode |
Not Present |
RBR-205 |
||
|
– E-AGCH Info |
Not present |
Rel-6 |
RBR-206 |
|
|
– E-HICH Information |
Not present |
Rel-6 |
RBR-207 |
|
|
– E-RGCH Information |
Not present |
Rel-6 |
RBR-208 |
|
|
– SCCPCH information for FACH |
Not Present |
R99 and Rel-4 only |
RBR-209 |
|
|
Downlink information for each radio link list |
A4 |
RBR-210 |
||
|
-Downlink information for each radio link |
RBR-211 |
|||
|
– Choice mode |
FDD |
RBR-212 |
||
|
– Primary CPICH info |
RBR-213 |
|||
|
– Primary scrambling code |
Ref. to the Default setting in clause 6.1 (FDD) |
RBR-214 |
||
|
– PDSCH with SHO DCH info |
Not Present |
R99 and Rel-4 only |
RBR-215 |
|
|
– PDSCH code mapping |
Not Present |
R99 and Rel-4 only |
RBR-216 |
|
|
– Serving HS-DSCH radio link indicator |
FALSE |
Rel-5 |
RBR-217 |
|
|
– Serving E-DCH radio link indicator |
FALSE |
Rel-6 |
RBR-218 |
|
|
– Downlink DPCH info for each RL |
RBR-219 |
|||
|
– Primary CPICH usage for channel estimation |
Primary CPICH may be used |
RBR-220 |
||
|
– DPCH frame offset |
Set to value : Default DPCH Offset Value mod 38 400 |
RBR-221 |
||
|
– Secondary CPICH info |
Not Present |
RBR-222 |
||
|
– Secondary scrambling code |
RBR-223 |
|||
|
– channelisation code |
RBR-224 |
|||
|
– DL channelisation code |
RBR-225 |
|||
|
– Secondary scrambling code |
3 |
RBR-226 |
||
|
– Spreading factor |
Reference to clause 6.10 Parameter Set |
RBR-227 |
||
|
– Code number |
0 |
RBR-228 |
||
|
– Scrambling code change |
Set to value Default1: No code change (if the UE has a compressed mode pattern sequence configured in variable TGPS_IDENTITY or included in the message including IE "Downlink DPCH info for each RL", which is using compressed mode method "SF/2") Set to value Default2: OMIT (otherwise) |
RBR-229 |
||
|
– TPC combination index |
0 |
RBR-230 |
||
|
– SSDT Cell Identity |
Not Present |
R99 and Rel-4 only |
RBR-231 |
|
|
– Closed loop timing adjustment mode |
Not Present |
RBR-232 |
||
|
– E-AGCH Info |
Not present |
Rel-6 |
RBR-233 |
|
|
– E-HICH Information |
Not present |
Rel-6 |
RBR-234 |
|
|
– E-RGCH Information |
Not present |
Rel-6 |
RBR-235 |
|
|
– SCCPCH information for FACH |
Not Present |
R99 and Rel-4 only |
RBR-236 |
|
|
– Downlink information for each radio link |
A5, A7, A8 |
RBR-237 |
||
|
– Choice mode |
FDD |
RBR-238 |
||
|
– Primary CPICH info |
RBR-239 |
|||
|
– Primary scrambling code |
Ref. to the Default setting in clause 6.1 (FDD) |
RBR-240 |
||
|
– PDSCH with SHO DCH info |
Not Present |
R99 and Rel-4 only |
RBR-241 |
|
|
– PDSCH code mapping |
Not Present |
R99 and Rel-4 only |
RBR-242 |
|
|
– Serving HS-DSCH radio link indicator |
FALSE |
Rel-5 |
RBR-243 |
|
|
– Serving E-DCH radio link indicator |
FALSE |
Rel-6 |
RBR-244 |
|
|
– Downlink DPCH info for each RL |
Not present |
RBR-245 |
||
|
– E-AGCH Info |
Not present |
Rel-6 |
RBR-246 |
|
|
– E-HICH Information |
Not present |
Rel-6 |
RBR-247 |
|
|
– E-RGCH Information |
Not present |
Rel-6 |
RBR-248 |
|
|
– SCCPCH information for FACH |
Not Present |
R99 and Rel-4 only |
RBR-249 |
|
|
– Downlink information for each radio link |
A6, A10 |
Not Present |
RBR-250 |
|
|
MBMS PL Service Restriction Information |
A1,A2, A3,A4,A5, A6, A7, A8, A9, A10 |
Not Present |
Rel-6 |
RBR-251 |
|
MBMS RB list released to change transfer mode |
Not Present |
Rel-6 |
RBR-252 |
|
Condition |
Explanation |
Version |
|
A1 |
This IE need for "Non speech in CS" |
|
|
A2 |
This IE need for "Speech in CS" |
|
|
A3 |
This IE need for "Packet to CELL_DCH from CELL_DCH in PS" |
|
|
A4 |
This IE need for "Packet to CELL_DCH from CELL_FACH in PS" |
|
|
A5 |
This IE need for "Packet to CELL_FACH from CELL_DCH in PS" |
|
|
A6 |
This IE need for "Packet to CELL_FACH from CELL_FACH in PS" |
|
|
A7 |
This IE need for "Non speech to CELL_FACH from CELL_DCH in CS" |
|
|
A8 |
This IE need for "Speech to CELL_FACH from CELL_DCH in CS" |
|
|
A9 |
This IE is needed for "Packet to CELL_DCH / HS-DSCH using three multiplexing options", or when not stated otherwise, for "Packet to CELL_DCH from CELL_DCH / HS-DSCH in PS" |
Rel-5 |
|
A10 |
This IE is needed for "Packet to CELL_DCH / HS-DSCH using one multiplexing option", or when not stated otherwise, for "Packet to CELL_FACH from CELL_DCH / HS-DSCH in PS" |
Rel-5 |
Contents of RADIO BEARER RELEASE COMPLETE message: AM
|
Information Element |
Value/remark |
|
Message Type |
|
|
RRC transaction identifier |
Checked to see the value is identical to the same IE in the downlink RADIO BEARER RELEASE message. |
|
Integrity check info |
|
|
– Message authentication code |
This IE is checked to see if it is present. The value is compared against the XMAC-I value computed by SS. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
|
– RRC Message sequence number |
This IE is checked to see if it is present. The value is used by SS to compute the XMAC-I value. |
|
Uplink integrity protection activation info |
Not checked. |
|
CHOICE mode |
FDD |
|
Deferred measurement control reading |
Not present for Rel-7 or later, otherwise Not checked |
|
COUNT-C activation time |
Not checked |
|
Radio bearer uplink ciphering activation time info |
Not checked |
|
Uplink counter synchronization info |
Not present |
Contents of RADIO BEARER RELEASE FAILURE message: AM
|
Information Element |
Value/remark |
|
Message Type |
|
|
RRC transaction identifier |
Checked to see if it is set to identical value of the same IE in the downlink RADIO BEARER RELEASE message. |
|
Integrity check info |
|
|
– Message authentication code |
This IE is checked to see if it is present. The value is compared against the XMAC-I value computed by SS. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
|
– RRC Message sequence number |
This IE is checked to see if it is present. The value is used by SS to compute the XMAC-I value. |
|
Failure cause |
Checked to see if it meets test requirement |
|
Radio bearers for which reconfiguration would have succeeded |
Not checked |
Contents of RRC CONNECTION REQUEST message: TM
|
Information Element |
Condition |
Value/remark |
Version |
|
Message Type |
|||
|
Predefined configuration status information |
To be checked against requirement if specified |
Rel-5 |
|
|
Initial UE identity |
|||
|
– CHOICE UE id type |
|||
|
– TMSI and LAI (GSM-MAP) |
Set to the UE’s TMSI and LAI. |
||
|
Establishment cause |
To be checked against requirement if specified |
||
|
Protocol error indicator |
FALSE |
||
|
UE Specific Behaviour Information 1 idle |
This IE will not be checked by default behaviour, but in specific test case. |
||
|
Domain indicator |
To be checked against requirement if specified |
Rel-6 |
|
|
Call type |
To be checked against requirement if specified |
Rel-6 |
|
|
UE capability indication |
To be checked against requirement if specified |
Rel-6 |
|
|
Support for F-DPCH |
A1 |
TRUE |
Rel-6 |
|
Support for F-DPCH |
A2 |
Not Present |
Rel-6 |
|
UE Mobility State Indicator |
Not Present |
Rel-7 |
|
|
Support for Enhanced F-DPCH |
To be checked against requirement if specified |
Rel-7 |
|
|
HS-PDSCH in CELL_FACH |
To be checked against requirement if specified |
Rel-7 |
|
|
MAC-ehs support |
To be checked against requirement if specified |
Rel-7 |
|
|
DPCCH Discontinuous Transmission support |
To be checked against requirement if specified |
Rel-7 |
|
|
Measured results on RACH |
To be checked against requirement if specified |
Rel-4 |
|
|
Access stratum release indicator |
To be checked against requirement if specified |
Rel-4 |
|
Condition |
Explanation |
|
A1 |
This IE need to be set to TRUE when F-DPCH is fully supported by the UE. |
|
A2 |
This IE need to be absent when F-DPCH is not fully supported by the UE. |
Contents of RRC CONNECTION REJECT message: UM
|
Information Element |
Value/remark |
|
Message Type |
|
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
|
Initial UE identity |
Select the same type as in the IE "Initial UE Identity" in RRC CONNECTION REQUEST" message. |
|
Rejection cause |
Unspecified |
|
Wait Time |
0 |
|
Redirection info |
Not Present |
Contents of RRC CONNECTION RELEASE message: UM
|
Information Element |
Value/remark |
Version |
|
Message Type |
||
|
U-RNTI |
This IE is set to the following value when the message is transmitted on the CCCH. When transmitted on DCCH, this is absent. |
R99, Rel-4 |
|
– SRNC identity |
0000 0000 0001B |
|
|
– S-RNTI |
0000 0000 0000 0000 0001B |
|
|
CHOICE identity type |
This IE is set to the following value when the message is transmitted on the CCCH. When transmitted on DCCH, this is absent. |
Rel-5 |
|
– U-RNTI |
||
|
– SRNC identity |
0000 0000 0001B |
|
|
– S-RNTI |
0000 0000 0000 0000 0001B |
|
|
– Group identity |
[FFS] |
|
|
– Group release information |
[FFS] |
|
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
|
|
Integrity check info |
This IE is present when this message is transmitted on downlink DCCH. Else, this IE and the sub-IEs are omitted. |
|
|
– Message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
|
|
– RRC Message sequence number |
SS provides the value of this IE, from its internal counter. |
|
|
N308 |
2 (for CELL_DCH state). Not Present (for UE in other connected mode states). |
|
|
Release cause |
Normal event |
|
|
UE Mobility State Indicator |
Not Present |
Rel-7 |
|
Rplmn information |
Not Present |
Contents of RRC CONNECTION RELEASE COMPLETE message: AM or UM
|
Information Element |
Semantics description |
|
Message Type |
|
|
RRC transaction identifier |
The value of this IE is checked to see that it matches the value of the same IE transmitted in the downlink RRC CONNECTION RELEASE message. |
|
Integrity check info |
|
|
– Message authentication code |
Checked to see if it’s identical to the value of XMAC-I calculated by the SS. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
|
– RRC Message sequence number |
Checked to see if it is present. This number is used by the SS to compute the XMAC-I |
|
Error indication |
Not checked |
Contents of RRC CONNECTION SETUP message: UM (Transition to CELL_DCH or in CELL_FACH)
|
Information Element |
Condition |
Value/remark |
Version |
Index |
|
|---|---|---|---|---|---|
|
Message Type |
A1, A2, A3 , A4, A5, A6 |
RCS-001 |
|||
|
Initial UE identity |
Select the same identity as in the IE "Initial UE Identity" in received RRC CONNECTION REQUEST" message |
RCS-002 |
|||
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
RCS-003 |
|||
|
Activation time |
Not Present(Now) |
RCS-004 |
|||
|
New U-RNTI |
RCS-005 |
||||
|
– SRNC identity |
0000 0000 0001B |
RCS-006 |
|||
|
– S-RNTI |
0000 0000 0000 0000 0001B |
RCS-007 |
|||
|
New C-RNTI |
A1, A2, A3 |
Not present |
RCS-008 |
||
|
A4, A6 |
‘1010 1010 1010 1010’ |
Rel-7 |
RCS-009 |
||
|
New H-RNTI |
A1 |
Not present |
Rel-6 |
RCS-010 |
|
|
A2 |
‘1010 1010 1010 1010’ |
Rel-6 |
RCS-011 |
||
|
A3, A4 |
Rel-7 |
RCS-012 |
|||
|
A5, A6 |
Rel-8 |
RCS-013 |
|||
|
New Primary E-RNTI |
A1 |
Not present |
Rel-6 |
RCS-014 |
|
|
A2, A3 |
‘1010 1010 1010 1010’ |
Rel-7 |
RCS-015 |
||
|
A5, A6 |
Rel-8 |
RCS-016 |
|||
|
New Secondary E-RNTI |
Not present |
Rel-6 |
RCS-017 |
||
|
RRC State Indicator |
CELL_DCH |
RCS-018 |
|||
|
RRC State Indicator |
A4, A6 |
CELL_FACH |
RCS-019 |
||
|
UTRAN DRX cycle length coefficient |
9 |
RCS-020 |
|||
|
Capability update requirement |
RCS-021 |
||||
|
– UE radio access FDD capability update requirement |
TRUE |
RCS-022 |
|||
|
– UE radio access TDD capability update requirement |
FALSE |
RCS-023 |
|||
|
– UE radio access 3.84 Mcps TDD capability update requirement |
FALSE |
Rel-4 |
RCS-024 |
||
|
– UE radio access 1.28 Mcps TDD capability update requirement |
FALSE |
Rel-4 |
RCS-025 |
||
|
– System specific capability update requirement list |
GSM |
RCS-026 |
|||
|
– System specific capability update requirement list |
UTRAN to E-UTRA |
GSM, EUTRA |
Rel-8 |
NOTE 2 |
|
|
RNC support for change of UE capability |
FALSE |
Rel-7 |
RCS-027 |
||
|
CHOICE specification mode |
Complete specification |
Rel-5 |
RCS-028 |
||
|
– Complete specification |
Rel-5 |
RCS-029 |
|||
|
– Signalling RB information to setup |
A1 |
(UM DCCH for RRC) |
RCS-030 |
||
|
– RB identity |
Not Present |
RCS-031 |
|||
|
– CHOICE RLC info type |
RCS-032 |
||||
|
– RLC info |
RCS-033 |
||||
|
– CHOICE Uplink RLC mode |
UM RLC |
RCS-034 |
|||
|
– Transmission RLC discard |
Not Present |
RCS-035 |
|||
|
– CHOICE Downlink RLC mode |
UM RLC |
RCS-036 |
|||
|
– DL UM RLC LI size |
7 bit |
Rel-6 |
RCS-037 |
||
|
– One sided RLC re-establishment |
FALSE |
Rel-6 |
RCS-038 |
||
|
– RB mapping info |
RCS-039 |
||||
|
– Information for each multiplexing option |
2 RBMuxOptions |
RCS-040 |
|||
|
– RLC logical channel mapping indicator |
Not Present |
RCS-041 |
|||
|
– Number of RLC logical channels |
1 |
RCS-042 |
|||
|
– Uplink transport channel type |
DCH |
RCS-043 |
|||
|
– UL Transport channel identity |
5 |
RCS-044 |
|||
|
– Logical channel identity |
1 |
RCS-045 |
|||
|
– CHOICE RLC size list |
Configured |
RCS-046 |
|||
|
– MAC logical channel priority |
1 |
RCS-047 |
|||
|
– Downlink RLC logical channel info |
RCS-048 |
||||
|
– Number of RLC logical channels |
1 |
RCS-049 |
|||
|
– Downlink transport channel type |
DCH |
RCS-050 |
|||
|
– DL DCH Transport channel identity |
10 |
RCS-051 |
|||
|
– DL DSCH Transport channel identity |
Not Present |
RCS-052 |
|||
|
– Logical channel identity |
1 |
RCS-053 |
|||
|
– RLC logical channel mapping indicator |
Not Present |
RCS-054 |
|||
|
– Number of RLC logical channels |
1 |
RCS-055 |
|||
|
– Uplink transport channel type |
RACH |
RCS-056 |
|||
|
– UL Transport channel identity |
Not Present |
RCS-057 |
|||
|
– Logical channel identity |
1 |
RCS-058 |
|||
|
– CHOICE RLC size list |
Explicit List |
RCS-059 |
|||
|
– RLC size index |
According to clause 6.10.2.4.1.3 (standalone 13.6 kbps signalling radio bearer) |
RCS-060 |
|||
|
– MAC logical channel priority |
1 |
RCS-061 |
|||
|
– Downlink RLC logical channel info |
RCS-062 |
||||
|
– Number of RLC logical channels |
1 |
RCS-063 |
|||
|
– Downlink transport channel type |
FACH |
RCS-064 |
|||
|
– DL DCH Transport channel identity |
Not Present |
RCS-065 |
|||
|
– DL DSCH Transport channel identity |
Not Present |
RCS-066 |
|||
|
– Logical channel identity |
1 |
RCS-067 |
|||
|
– Signalling RB information to setup |
A2 |
(UM DCCH for RRC) |
Rel-6 |
RCS-068 |
|
|
– RB identity |
Not Present |
RCS-069 |
|||
|
– CHOICE RLC info type |
RCS-070 |
||||
|
– RLC info |
RCS-071 |
||||
|
– CHOICE Uplink RLC mode |
UM RLC |
RCS-072 |
|||
|
– Transmission RLC discard |
Not Present |
RCS-073 |
|||
|
– CHOICE Downlink RLC mode |
UM RLC |
RCS-074 |
|||
|
– DL UM RLC LI size |
7 bit |
Rel-6 |
RCS-075 |
||
|
– One sided RLC re-establishment |
FALSE |
Rel-6 |
RCS-076 |
||
|
– RB mapping info |
RCS-077 |
||||
|
– Information for each multiplexing option |
1 RBMuxOption |
RCS-078 |
|||
|
– RLC logical channel mapping indicator |
Not Present |
RCS-079 |
|||
|
– Number of RLC logical channels |
1 |
RCS-080 |
|||
|
– Uplink transport channel type |
E-DCH |
RCS-081 |
|||
|
– Logical channel identity |
1 |
RCS-082 |
|||
|
– E-DCH MAC-d flow identity |
1 |
RCS-083 |
|||
|
– DDI |
1 |
RCS-084 |
|||
|
– RLC PDU size list |
1 RLC PDU size |
RCS-085 |
|||
|
– RLC PDU size |
144 bits |
RCS-086 |
|||
|
– Include in scheduling info |
FALSE |
RCS-087 |
|||
|
– MAC logical channel priority |
1 |
RCS-088 |
|||
|
– Downlink RLC logical channel info |
RCS-089 |
||||
|
– Number of RLC logical channels |
1 |
RCS-090 |
|||
|
– Downlink transport channel type |
HS-DSCH |
RCS-091 |
|||
|
– DL DCH Transport channel identity |
Not present |
RCS-092 |
|||
|
– DL DSCH Transport channel identity |
Not Present |
RCS-093 |
|||
|
– DL HS-DSCH MAC-d flow identity |
1 |
RCS-094 |
|||
|
– Logical channel identity |
1 |
RCS-095 |
|||
|
– Signalling RB information to setup |
A3 |
(UM DCCH for RRC) |
Rel-7 |
RCS-096 |
|
|
A5, A6 |
Rel-8 |
RCS-097 |
|||
|
– RB identity |
Not present |
RCS-098 |
|||
|
– CHOICE RLC info type |
RCS-099 |
||||
|
– RLC info |
RCS-100 |
||||
|
– CHOICE Uplink RLC mode |
UM RLC |
RCS-101 |
|||
|
– Transmission RLC discard |
Not Present |
RCS-102 |
|||
|
– CHOICE Downlink RLC mode |
UM RLC |
RCS-103 |
|||
|
– DL UM RLC LI size |
7 bit |
RCS-104 |
|||
|
– One sided RLC re-establishment |
FALSE |
RCS-105 |
|||
|
– Alternative E-bit interpretation |
TRUE |
RCS-106 |
|||
|
– Use special value of HE field |
Not present |
RCS-107 |
|||
|
– RB mapping info |
RCS-108 |
||||
|
– Information for each multiplexing option |
1 RBMuxOption |
RCS-109 |
|||
|
– RLC logical channel mapping indicator |
Not Present |
RCS-110 |
|||
|
– Number of RLC logical channels |
1 |
RCS-111 |
|||
|
– Uplink transport channel type |
E-DCH |
RCS-112 |
|||
|
– Logical channel identity |
1 |
RCS-113 |
|||
|
– E-DCH MAC-d flow identity |
1 |
RCS-114 |
|||
|
– DDI |
1 |
RCS-115 |
|||
|
– CHOICE RLC PDU size |
Fixed size |
Rel-8 |
RCS-116 |
||
|
– RLC PDU size list |
1 RLC PDU size |
RCS-117 |
|||
|
– RLC PDU size |
144 bits |
RCS-118 |
|||
|
– Include in scheduling info |
FALSE |
RCS-119 |
|||
|
– MAC logical channel priority |
1 |
RCS-120 |
|||
|
– Downlink RLC logical channel info |
RCS-121 |
||||
|
– Number of RLC logical channels |
1 |
RCS-122 |
|||
|
– Downlink transport channel type |
HS-DSCH |
RCS-123 |
|||
|
– DL DCH Transport channel identity |
Not present |
RCS-124 |
|||
|
– DL DSCH Transport channel identity |
Not Present |
RCS-125 |
|||
|
– CHOICE DL MAC header type |
MAC-ehs |
RCS-126 |
|||
|
– DL HS-DSCH MAC-ehs Queue Id |
1 |
RCS-127 |
|||
|
– Logical channel identity |
1 |
RCS-128 |
|||
|
– Signalling RB information to setup |
A4 |
(UM DCCH for RRC) |
Rel-7 |
RCS-129 |
|
|
– RB identity |
Not present |
RCS-130 |
|||
|
– CHOICE RLC info type |
RCS-131 |
||||
|
– RLC info |
RCS-132 |
||||
|
– CHOICE Uplink RLC mode |
UM RLC |
RCS-133 |
|||
|
– Transmission RLC discard |
Not Present |
RCS-134 |
|||
|
– CHOICE Downlink RLC mode |
UM RLC |
RCS-135 |
|||
|
– DL UM RLC LI size |
7 bit |
RCS-136 |
|||
|
– One sided RLC re-establishment |
FALSE |
RCS-137 |
|||
|
– Alternative E-bit interpretation |
Not Present |
RCS-138 |
|||
|
– Use special value of HE field |
Not Present |
RCS-139 |
|||
|
– RB mapping info |
RCS-140 |
||||
|
– Information for each multiplexing option |
1 RBMuxOption |
RCS-141 |
|||
|
– RLC logical channel mapping indicator |
Not Present |
RCS-142 |
|||
|
– Number of RLC logical channels |
1 |
RCS-143 |
|||
|
– Uplink transport channel type |
RACH |
RCS-144 |
|||
|
– UL Transport channel identity |
Not Present |
RCS-145 |
|||
|
– Logical channel identity |
1 |
RCS-146 |
|||
|
– CHOICE RLC size list |
According to clause 6.10.2.4.4.1 (combinations on PRACH) |
RCS-147 |
|||
|
– MAC logical channel priority |
1 |
RCS-148 |
|||
|
– Downlink RLC logical channel info |
RCS-149 |
||||
|
– Number of RLC logical channels |
1 |
RCS-150 |
|||
|
– Downlink transport channel type |
HS-DSCH |
RCS-151 |
|||
|
– DL DCH Transport channel identity |
Not present |
RCS-152 |
|||
|
– DL DSCH Transport channel identity |
Not Present |
RCS-153 |
|||
|
– CHOICE DL MAC header type |
MAC-ehs |
RCS-154 |
|||
|
– DL HS-DSCH MAC-ehs Queue Id |
1 |
RCS-155 |
|||
|
– Logical channel identity |
1 |
RCS-156 |
|||
|
– Signalling RB information to setup |
A1 |
(AM DCCH for RRC) |
RCS-157 |
||
|
– RB identity |
Not Present |
RCS-158 |
|||
|
– CHOICE RLC info type |
RCS-159 |
||||
|
– RLC info |
RCS-160 |
||||
|
– CHOICE Uplink RLC mode |
AM RLC |
RCS-161 |
|||
|
– Transmission RLC discard |
RCS-162 |
||||
|
– SDU discard mode |
No discard |
RCS-163 |
|||
|
– MAX_DAT |
15 |
RCS-164 |
|||
|
– Transmission window size |
32 |
RCS-165 |
|||
|
– Timer_RST |
500 |
RCS-166 |
|||
|
– Max_RST |
1 |
RCS-167 |
|||
|
– Polling info |
RCS-168 |
||||
|
– Timer_poll_prohibit |
200 |
RCS-169 |
|||
|
– Timer_poll |
200 |
RCS-170 |
|||
|
– Poll_PDU |
Not Present |
RCS-171 |
|||
|
– Poll_SDU |
1 |
RCS-172 |
|||
|
– Last transmission PDU poll |
TRUE |
RCS-173 |
|||
|
– Last retransmission PDU poll |
TRUE |
RCS-174 |
|||
|
– Poll_Window |
99 |
RCS-175 |
|||
|
– Timer_poll_periodic |
Not Present |
RCS-176 |
|||
|
– CHOICE Downlink RLC mode |
AM RLC |
RCS-177 |
|||
|
– DL RLC PDU size |
According to clause 6.10.2.4.1.3 (standalone 13.6 kbps signalling radio bearer) |
Rel-6 |
RCS-178 |
||
|
– In-sequence delivery |
TRUE |
RCS-179 |
|||
|
– Receiving window size |
32 |
RCS-180 |
|||
|
– Downlink RLC status info |
RCS-181 |
||||
|
– Timer_status_prohibit |
200 |
RCS-182 |
|||
|
– Timer_EPC |
Not Present |
RCS-183 |
|||
|
– Missing PDU indicator |
TRUE |
RCS-184 |
|||
|
– Timer_STATUS_periodic |
Not Present |
RCS-185 |
|||
|
– RB mapping info |
RCS-186 |
||||
|
– Information for each multiplexing option |
2 RBMuxOptions |
RCS-187 |
|||
|
– RLC logical channel mapping indicator |
Not Present |
RCS-188 |
|||
|
– Number of RLC logical channels |
1 |
RCS-189 |
|||
|
– Uplink transport channel type |
DCH |
RCS-190 |
|||
|
– UL Transport channel identity |
5 |
RCS-191 |
|||
|
– Logical channel identity |
2 |
RCS-192 |
|||
|
– CHOICE RLC size list |
Configured |
RCS-193 |
|||
|
– MAC logical channel priority |
2 |
RCS-194 |
|||
|
– Downlink RLC logical channel info |
RCS-195 |
||||
|
– Number of RLC logical channels |
1 |
RCS-196 |
|||
|
– Downlink transport channel type |
DCH |
RCS-197 |
|||
|
– DL DCH Transport channel identity |
10 |
RCS-198 |
|||
|
– DL DSCH Transport channel identity |
Not Present |
RCS-199 |
|||
|
– Logical channel identity |
2 |
RCS-200 |
|||
|
– RLC logical channel mapping indicator |
Not Present |
RCS-201 |
|||
|
– Number of RLC logical channels |
1 |
RCS-202 |
|||
|
– Uplink transport channel type |
RACH |
RCS-203 |
|||
|
– UL Transport channel identity |
Not Present |
RCS-204 |
|||
|
– Logical channel identity |
2 |
RCS-205 |
|||
|
– CHOICE RLC size list |
Explicit List |
RCS-206 |
|||
|
– RLC size index |
According to clause 6.10.2.4.1.3 (standalone 13.6 kbps signalling radio bearer) |
RCS-207 |
|||
|
– MAC logical channel priority |
2 |
RCS-208 |
|||
|
– Downlink RLC logical channel info |
RCS-209 |
||||
|
– Number of RLC logical channels |
1 |
RCS-210 |
|||
|
– Downlink transport channel type |
FACH |
RCS-211 |
|||
|
– DL DCH Transport channel identity |
Not Present |
RCS-212 |
|||
|
– DL DSCH Transport channel identity |
Not Present |
RCS-213 |
|||
|
– Logical channel identity |
2 |
RCS-214 |
|||
|
– Signalling RB information to setup |
A2 |
(AM DCCH for RRC) |
Rel-6 |
RCS-215 |
|
|
– RB identity |
Not Present |
RCS-216 |
|||
|
– CHOICE RLC info type |
RCS-217 |
||||
|
– RLC info |
RCS-218 |
||||
|
– CHOICE Uplink RLC mode |
AM RLC |
RCS-219 |
|||
|
– Transmission RLC discard |
RCS-220 |
||||
|
– SDU discard mode |
No discard |
RCS-221 |
|||
|
– MAX_DAT |
15 |
RCS-222 |
|||
|
– Transmission window size |
32 |
RCS-223 |
|||
|
– Timer_RST |
500 |
RCS-224 |
|||
|
– Max_RST |
1 |
RCS-225 |
|||
|
– Polling info |
RCS-226 |
||||
|
– Timer_poll_prohibit |
200 |
RCS-227 |
|||
|
– Timer_poll |
200 |
RCS-228 |
|||
|
– Poll_PDU |
Not Present |
RCS-229 |
|||
|
– Poll_SDU |
1 |
RCS-230 |
|||
|
– Last transmission PDU poll |
TRUE |
RCS-231 |
|||
|
– Last retransmission PDU poll |
TRUE |
RCS-232 |
|||
|
– Poll_Window |
99 |
RCS-233 |
|||
|
– Timer_poll_periodic |
Not Present |
RCS-234 |
|||
|
– CHOICE Downlink RLC mode |
AM RLC |
RCS-235 |
|||
|
– In-sequence delivery |
TRUE |
RCS-236 |
|||
|
– Receiving window size |
32 |
RCS-237 |
|||
|
– Downlink RLC status info |
RCS-238 |
||||
|
– Timer_status_prohibit |
200 |
RCS-239 |
|||
|
– Timer_EPC |
Not Present |
RCS-240 |
|||
|
– Missing PDU indicator |
TRUE |
RCS-241 |
|||
|
– Timer_STATUS_periodic |
Not Present |
RCS-242 |
|||
|
– RB mapping info |
RCS-243 |
||||
|
– Information for each multiplexing option |
1 RBMuxOption |
RCS-244 |
|||
|
– RLC logical channel mapping indicator |
Not Present |
RCS-245 |
|||
|
– Number of RLC logical channels |
1 |
RCS-246 |
|||
|
– Uplink transport channel type |
E-DCH |
RCS-247 |
|||
|
– Logical channel identity |
2 |
RCS-248 |
|||
|
– E-DCH MAC-d flow identity |
1 |
RCS-249 |
|||
|
– DDI |
2 |
RCS-250 |
|||
|
– RLC PDU size list |
1 RLC PDU size |
RCS-251 |
|||
|
– RLC PDU size |
144 bits |
RCS-252 |
|||
|
– Include in scheduling info |
FALSE |
RCS-253 |
|||
|
– MAC logical channel priority |
2 |
RCS-254 |
|||
|
– Downlink RLC logical channel info |
RCS-255 |
||||
|
– Number of RLC logical channels |
1 |
RCS-256 |
|||
|
– Downlink transport channel type |
HS-DSCH |
RCS-257 |
|||
|
– DL DCH Transport channel identity |
Not Present |
RCS-258 |
|||
|
– DL DSCH Transport channel identity |
Not Present |
RCS-259 |
|||
|
– DL HS-DSCH MAC-d flow identity |
1 |
RCS-260 |
|||
|
– Logical channel identity |
2 |
RCS-261 |
|||
|
– Signalling RB information to setup |
A3 |
(AM DCCH for RRC) |
Rel-7 |
RCS-262 |
|
|
A5, A6 |
Rel-8 |
RCS-263 |
|||
|
– RB identity |
Not present |
RCS-264 |
|||
|
– CHOICE RLC info type |
RCS-265 |
||||
|
– RLC info |
RCS-266 |
||||
|
– CHOICE Uplink RLC mode |
AM RLC |
RCS-267 |
|||
|
– Transmission RLC discard |
RCS-268 |
||||
|
– SDU discard mode |
No discard |
RCS-269 |
|||
|
– MAX_DAT |
15 |
RCS-270 |
|||
|
– Transmission window size |
32 |
RCS-271 |
|||
|
– Timer_RST |
500 |
RCS-272 |
|||
|
– Max_RST |
1 |
RCS-273 |
|||
|
– Polling info |
RCS-274 |
||||
|
– Timer_poll_prohibit |
200 |
RCS-275 |
|||
|
– Timer_poll |
200 |
RCS-276 |
|||
|
– Poll_PDU |
Not Present |
RCS-277 |
|||
|
– Poll_SDU |
1 |
RCS-278 |
|||
|
– Last transmission PDU poll |
TRUE |
RCS-279 |
|||
|
– Last retransmission PDU poll |
TRUE |
RCS-280 |
|||
|
– Poll_Window |
99 |
RCS-281 |
|||
|
– Timer_poll_periodic |
Not Present |
RCS-282 |
|||
|
– CHOICE Downlink RLC mode |
AM RLC |
RCS-283 |
|||
|
– CHOICE Downlink RLC PDU Size |
Reference to clause 6 Parameter Set |
RCS-284 |
|||
|
– Length indicator size |
7 |
RCS-285 |
|||
|
– In-sequence delivery |
TRUE |
RCS-286 |
|||
|
– Receiving window size |
32 |
RCS-287 |
|||
|
– Downlink RLC status info |
RCS-288 |
||||
|
– Timer_status_prohibit |
200 |
RCS-289 |
|||
|
– Timer_EPC |
Not Present |
RCS-290 |
|||
|
– Missing PDU indicator |
TRUE |
RCS-291 |
|||
|
– Timer_STATUS_periodic |
Not Present |
RCS-292 |
|||
|
– Alternative E-bit interpretation |
Not Present |
RCS-293 |
|||
|
– Use special value of HE field |
TRUE |
RCS-294 |
|||
|
– RB mapping info |
RCS-295 |
||||
|
– Information for each multiplexing option |
1 RBMuxOption |
RCS-296 |
|||
|
– RLC logical channel mapping indicator |
Not Present |
RCS-297 |
|||
|
– Number of RLC logical channels |
1 |
RCS-298 |
|||
|
– Uplink transport channel type |
E-DCH |
RCS-299 |
|||
|
– Logical channel identity |
2 |
RCS-300 |
|||
|
– E-DCH MAC-d flow identity |
1 |
RCS-301 |
|||
|
– DDI |
2 |
RCS-302 |
|||
|
– CHOICE RLC PDU size |
Fixed size |
Rel-8 |
RCS-303 |
||
|
– RLC PDU size list |
1 RLC PDU size |
RCS-304 |
|||
|
– RLC PDU size |
144 bits |
RCS-305 |
|||
|
– Include in scheduling info |
FALSE |
RCS-306 |
|||
|
– MAC logical channel priority |
2 |
RCS-307 |
|||
|
– Downlink RLC logical channel info |
RCS-308 |
||||
|
– Number of RLC logical channels |
1 |
RCS-309 |
|||
|
– Downlink transport channel type |
HS-DSCH |
RCS-310 |
|||
|
– DL DCH Transport channel identity |
Not Present |
RCS-311 |
|||
|
– DL DSCH Transport channel identity |
Not Present |
RCS-312 |
|||
|
– CHOICE DL MAC header type |
MAC-ehs |
RCS-313 |
|||
|
– DL HS-DSCH MAC-ehs Queue Id |
1 |
RCS-314 |
|||
|
– Logical channel identity |
2 |
RCS-315 |
|||
|
– Signalling RB information to setup |
A4 |
(AM DCCH for RRC) |
Rel-7 |
RCS-316 |
|
|
– RB identity |
Not present |
RCS-317 |
|||
|
– CHOICE RLC info type |
RCS-318 |
||||
|
– RLC info |
RCS-319 |
||||
|
– CHOICE Uplink RLC mode |
AM RLC |
RCS-320 |
|||
|
– Transmission RLC discard |
RCS-321 |
||||
|
– SDU discard mode |
No discard |
RCS-322 |
|||
|
– MAX_DAT |
15 |
RCS-323 |
|||
|
– Transmission window size |
32 |
RCS-324 |
|||
|
– Timer_RST |
500 |
RCS-325 |
|||
|
– Max_RST |
1 |
RCS-326 |
|||
|
– Polling info |
RCS-327 |
||||
|
– Timer_poll_prohibit |
200 |
RCS-328 |
|||
|
– Timer_poll |
200 |
RCS-329 |
|||
|
– Poll_PDU |
Not Present |
RCS-330 |
|||
|
– Poll_SDU |
1 |
RCS-331 |
|||
|
– Last transmission PDU poll |
TRUE |
RCS-332 |
|||
|
– Last retransmission PDU poll |
TRUE |
RCS-333 |
|||
|
– Poll_Window |
99 |
RCS-334 |
|||
|
– Timer_poll_periodic |
Not Present |
RCS-335 |
|||
|
– CHOICE Downlink RLC mode |
AM RLC |
RCS-336 |
|||
|
– CHOICE Downlink RLC PDU Size |
Reference to clause 6 Parameter Set |
RCS-337 |
|||
|
– Length indicator size |
7 |
RCS-338 |
|||
|
– In-sequence delivery |
TRUE |
RCS-339 |
|||
|
– Receiving window size |
32 |
RCS-340 |
|||
|
– Downlink RLC status info |
RCS-341 |
||||
|
– Timer_status_prohibit |
200 |
RCS-342 |
|||
|
– Timer_EPC |
Not Present |
RCS-343 |
|||
|
– Missing PDU indicator |
TRUE |
RCS-344 |
|||
|
– Timer_STATUS_periodic |
Not Present |
RCS-345 |
|||
|
– Alternative E-bit interpretation |
Not Present |
RCS-346 |
|||
|
– Use special value of HE field |
Not Present |
RCS-347 |
|||
|
– RB mapping info |
RCS-348 |
||||
|
– Information for each multiplexing option |
1 RBMuxOption |
RCS-349 |
|||
|
– RLC logical channel mapping indicator |
Not Present |
RCS-350 |
|||
|
– Number of RLC logical channels |
1 |
RCS-351 |
|||
|
– Uplink transport channel type |
RACH |
RCS-352 |
|||
|
– UL Transport channel identity |
Not Present |
RCS-353 |
|||
|
– Logical channel identity |
2 |
RCS-354 |
|||
|
– CHOICE RLC size list |
Explicit List |
RCS-355 |
|||
|
– RLC size index |
According to clause 6.10.2.4.4.1 (combinations on PRACH) |
RCS-356 |
|||
|
– MAC logical channel priority |
2 |
RCS-357 |
|||
|
– Downlink RLC logical channel info |
RCS-358 |
||||
|
– Downlink transport channel type |
HS-DSCH |
RCS-359 |
|||
|
– DL DCH Transport channel identity |
Not Present |
RCS-360 |
|||
|
– DL DSCH Transport channel identity |
Not Present |
RCS-361 |
|||
|
– CHOICE DL MAC header type |
MAC-ehs |
RCS-362 |
|||
|
– DL HS-DSCH MAC-ehs Queue Id |
1 |
RCS-363 |
|||
|
– Logical channel identity |
2 |
RCS-364 |
|||
|
– Signalling RB information to setup |
A1 |
(AM DCCH for NAS_DT High priority) |
RCS-365 |
||
|
– RB identity |
Not Present |
RCS-366 |
|||
|
– CHOICE RLC info type |
RCS-367 |
||||
|
– RLC info |
RCS-368 |
||||
|
– CHOICE Uplink RLC mode |
AM RLC |
RCS-369 |
|||
|
– Transmission RLC discard |
RCS-370 |
||||
|
– SDU discard mode |
No discard |
RCS-371 |
|||
|
– MAX_DAT |
15 |
RCS-372 |
|||
|
– Transmission window size |
32 |
RCS-373 |
|||
|
– Timer_RST |
500 |
RCS-374 |
|||
|
– Max_RST |
1 |
RCS-375 |
|||
|
– Polling info |
RCS-376 |
||||
|
– Timer_poll_prohibit |
200 |
RCS-377 |
|||
|
– Timer_poll |
200 |
RCS-378 |
|||
|
– Poll_PDU |
Not present |
RCS-379 |
|||
|
– Poll_SDU |
1 |
RCS-380 |
|||
|
– Last transmission PDU poll |
TRUE |
RCS-381 |
|||
|
– Last retransmission PDU poll |
TRUE |
RCS-382 |
|||
|
– Poll_Window |
99 |
RCS-383 |
|||
|
– Timer_poll_periodic |
Not Present |
RCS-384 |
|||
|
– CHOICE Downlink RLC mode |
AM RLC |
RCS-385 |
|||
|
– DL RLC PDU size |
According to clause 6.10.2.4.1.3 (standalone 13.6 kbps signalling radio bearer) |
Rel-6 |
RCS-386 |
||
|
– In-sequence delivery |
TRUE |
RCS-387 |
|||
|
– Receiving window size |
32 |
RCS-388 |
|||
|
– Downlink RLC status info |
RCS-389 |
||||
|
– Timer_status_prohibit |
200 |
RCS-390 |
|||
|
– Timer_EPC |
Not present |
RCS-391 |
|||
|
– Missing PDU indicator |
TRUE |
RCS-392 |
|||
|
– Timer_STATUS_periodic |
Not Present |
RCS-393 |
|||
|
– RB mapping info |
RCS-394 |
||||
|
– Information for each multiplexing option |
2 RBMuxOptions |
RCS-395 |
|||
|
– RLC logical channel mapping indicator |
Not Present |
RCS-396 |
|||
|
– Number of RLC logical channels |
1 |
RCS-397 |
|||
|
– Uplink transport channel type |
DCH |
RCS-398 |
|||
|
– UL Transport channel identity |
5 |
RCS-399 |
|||
|
– Logical channel identity |
3 |
RCS-400 |
|||
|
– CHOICE RLC size list |
Configured |
RCS-401 |
|||
|
– MAC logical channel priority |
3 |
RCS-402 |
|||
|
– Downlink RLC logical channel info |
RCS-403 |
||||
|
– Number of RLC logical channels |
1 |
RCS-404 |
|||
|
– Downlink transport channel type |
DCH |
RCS-405 |
|||
|
– DL DCH Transport channel identity |
10 |
RCS-406 |
|||
|
– DL DSCH Transport channel identity |
Not Present |
RCS-407 |
|||
|
– Logical channel identity |
3 |
RCS-408 |
|||
|
– RLC logical channel mapping indicator |
Not Present |
RCS-409 |
|||
|
– Number of RLC logical channels |
1 |
RCS-410 |
|||
|
– Uplink transport channel type |
RACH |
RCS-411 |
|||
|
– UL Transport channel identity |
Not Present |
RCS-412 |
|||
|
– Logical channel identity |
3 |
RCS-413 |
|||
|
– CHOICE RLC size list |
Explicit List |
RCS-414 |
|||
|
– RLC size index |
According to clause 6.10.2.4.1.3 (standalone 13.6 kbps signalling radio bearer) |
RCS-415 |
|||
|
– MAC logical channel priority |
3 |
RCS-416 |
|||
|
– Downlink RLC logical channel info |
RCS-417 |
||||
|
– Number of RLC logical channels |
1 |
RCS-418 |
|||
|
– Downlink transport channel type |
FACH |
RCS-419 |
|||
|
– DL DCH Transport channel identity |
Not Present |
RCS-420 |
|||
|
– DL DSCH Transport channel identity |
Not Present |
RCS-421 |
|||
|
– Logical channel identity |
3 |
RCS-422 |
|||
|
– Signalling RB information to setup |
A2 |
(AM DCCH for NAS_DT High priority) |
Rel-6 |
RCS-423 |
|
|
– RB identity |
Not Present |
RCS-424 |
|||
|
– CHOICE RLC info type |
RCS-425 |
||||
|
– RLC info |
RCS-426 |
||||
|
– CHOICE Uplink RLC mode |
AM RLC |
RCS-427 |
|||
|
– Transmission RLC discard |
RCS-428 |
||||
|
– SDU discard mode |
No discard |
RCS-429 |
|||
|
– MAX_DAT |
15 |
RCS-430 |
|||
|
– Transmission window size |
32 |
RCS-431 |
|||
|
– Timer_RST |
500 |
RCS-432 |
|||
|
– Max_RST |
1 |
RCS-433 |
|||
|
– Polling info |
RCS-434 |
||||
|
– Timer_poll_prohibit |
200 |
RCS-435 |
|||
|
– Timer_poll |
200 |
RCS-436 |
|||
|
– Poll_PDU |
Not present |
RCS-437 |
|||
|
– Poll_SDU |
1 |
RCS-438 |
|||
|
– Last transmission PDU poll |
TRUE |
RCS-439 |
|||
|
– Last retransmission PDU poll |
TRUE |
RCS-440 |
|||
|
– Poll_Window |
99 |
RCS-441 |
|||
|
– Timer_poll_periodic |
Not Present |
RCS-442 |
|||
|
– CHOICE Downlink RLC mode |
AM RLC |
RCS-443 |
|||
|
– In-sequence delivery |
TRUE |
RCS-444 |
|||
|
– Receiving window size |
32 |
RCS-445 |
|||
|
– Downlink RLC status info |
RCS-446 |
||||
|
– Timer_status_prohibit |
200 |
RCS-447 |
|||
|
– Timer_EPC |
Not present |
RCS-448 |
|||
|
– Missing PDU indicator |
TRUE |
RCS-449 |
|||
|
– Timer_STATUS_periodic |
Not Present |
RCS-450 |
|||
|
– RB mapping info |
RCS-451 |
||||
|
– Information for each multiplexing option |
1 RBMuxOption |
RCS-452 |
|||
|
– RLC logical channel mapping indicator |
Not Present |
RCS-453 |
|||
|
– Number of RLC logical channels |
1 |
RCS-454 |
|||
|
– Uplink transport channel type |
E-DCH |
RCS-455 |
|||
|
– Logical channel identity |
3 |
RCS-456 |
|||
|
– E-DCH MAC-d flow identity |
1 |
RCS-457 |
|||
|
– DDI |
3 |
RCS-458 |
|||
|
– RLC PDU size list |
1 RLC PDU size |
RCS-459 |
|||
|
– RLC PDU size |
144 bits |
RCS-460 |
|||
|
– Include in scheduling info |
FALSE |
RCS-461 |
|||
|
– MAC logical channel priority |
3 |
RCS-462 |
|||
|
– Downlink RLC logical channel info |
RCS-463 |
||||
|
– Number of RLC logical channels |
1 |
RCS-464 |
|||
|
– Downlink transport channel type |
HS-DSCH |
RCS-465 |
|||
|
– DL DCH Transport channel identity |
Not Present |
RCS-466 |
|||
|
– DL DSCH Transport channel identity |
Not Present |
RCS-467 |
|||
|
– DL HS-DSCH MAC-d flow identity |
1 |
RCS-468 |
|||
|
– Logical channel identity |
3 |
RCS-469 |
|||
|
– Signalling RB information to setup |
A3 |
(AM DCCH for NAS_DT High priority) |
Rel-7 |
RCS-470 |
|
|
A5, A6 |
Rel-8 |
RCS-471 |
|||
|
– RB identity |
Not present |
RCS-472 |
|||
|
– CHOICE RLC info type |
RCS-473 |
||||
|
– RLC info |
RCS-474 |
||||
|
– CHOICE Uplink RLC mode |
AM RLC |
RCS-475 |
|||
|
– Transmission RLC discard |
RCS-476 |
||||
|
– SDU discard mode |
No discard |
RCS-477 |
|||
|
– MAX_DAT |
15 |
RCS-478 |
|||
|
– Transmission window size |
32 |
RCS-479 |
|||
|
– Timer_RST |
500 |
RCS-480 |
|||
|
– Max_RST |
1 |
RCS-481 |
|||
|
– Polling info |
RCS-482 |
||||
|
– Timer_poll_prohibit |
200 |
RCS-483 |
|||
|
– Timer_poll |
200 |
RCS-484 |
|||
|
– Poll_PDU |
Not Present |
RCS-485 |
|||
|
– Poll_SDU |
1 |
RCS-486 |
|||
|
– Last transmission PDU poll |
TRUE |
RCS-487 |
|||
|
– Last retransmission PDU poll |
TRUE |
RCS-488 |
|||
|
– Poll_Window |
99 |
RCS-489 |
|||
|
– Timer_poll_periodic |
Not Present |
RCS-490 |
|||
|
– CHOICE Downlink RLC mode |
AM RLC |
RCS-491 |
|||
|
– CHOICE Downlink RLC PDU Size |
Reference to clause 6 Parameter Set |
RCS-492 |
|||
|
– Length indicator size |
7 |
RCS-493 |
|||
|
– In-sequence delivery |
TRUE |
RCS-494 |
|||
|
– Receiving window size |
32 |
RCS-495 |
|||
|
– Downlink RLC status info |
RCS-496 |
||||
|
– Timer_status_prohibit |
200 |
RCS-497 |
|||
|
– Timer_EPC |
Not Present |
RCS-498 |
|||
|
– Missing PDU indicator |
TRUE |
RCS-499 |
|||
|
– Timer_STATUS_periodic |
Not Present |
RCS-500 |
|||
|
– Alternative E-bit interpretation |
Not Present |
RCS-501 |
|||
|
– Use special value of HE field |
TRUE |
RCS-502 |
|||
|
– RB mapping info |
RCS-503 |
||||
|
– Information for each multiplexing option |
1 RBMuxOption |
RCS-504 |
|||
|
– RLC logical channel mapping indicator |
Not Present |
RCS-505 |
|||
|
– Number of RLC logical channels |
1 |
RCS-506 |
|||
|
– Uplink transport channel type |
E-DCH |
RCS-507 |
|||
|
– Logical channel identity |
3 |
RCS-508 |
|||
|
– E-DCH MAC-d flow identity |
1 |
RCS-509 |
|||
|
– CHOICE RLC PDU size |
Fixed size |
Rel-8 |
RCS-510 |
||
|
– DDI |
2 |
RCS-511 |
|||
|
– RLC PDU size list |
1 RLC PDU size |
RCS-512 |
|||
|
– RLC PDU size |
144 bits |
RCS-513 |
|||
|
– Include in scheduling info |
FALSE |
RCS-514 |
|||
|
– MAC logical channel priority |
3 |
RCS-515 |
|||
|
– Downlink RLC logical channel info |
RCS-516 |
||||
|
– Number of RLC logical channels |
1 |
RCS-517 |
|||
|
– Downlink transport channel type |
HS-DSCH |
RCS-518 |
|||
|
– DL DCH Transport channel identity |
Not Present |
RCS-519 |
|||
|
– DL DSCH Transport channel identity |
Not Present |
RCS-520 |
|||
|
– CHOICE DL MAC header type |
MAC-ehs |
RCS-521 |
|||
|
– DL HS-DSCH MAC-ehs Queue Id |
1 |
RCS-522 |
|||
|
– Logical channel identity |
3 |
RCS-523 |
|||
|
– Signalling RB information to setup |
A4 |
(AM DCCH for NAS_DT High priority) |
Rel-7 |
RCS-524 |
|
|
– RB identity |
Not present |
RCS-525 |
|||
|
– CHOICE RLC info type |
RCS-526 |
||||
|
– RLC info |
RCS-527 |
||||
|
– CHOICE Uplink RLC mode |
AM RLC |
RCS-528 |
|||
|
– Transmission RLC discard |
RCS-529 |
||||
|
– SDU discard mode |
No discard |
RCS-530 |
|||
|
– MAX_DAT |
15 |
RCS-531 |
|||
|
– Transmission window size |
32 |
RCS-532 |
|||
|
– Timer_RST |
500 |
RCS-533 |
|||
|
– Max_RST |
1 |
RCS-534 |
|||
|
– Polling info |
RCS-535 |
||||
|
– Timer_poll_prohibit |
200 |
RCS-536 |
|||
|
– Timer_poll |
200 |
RCS-537 |
|||
|
– Poll_PDU |
Not Present |
RCS-538 |
|||
|
– Poll_SDU |
1 |
RCS-539 |
|||
|
– Last transmission PDU poll |
TRUE |
RCS-540 |
|||
|
– Last retransmission PDU poll |
TRUE |
RCS-541 |
|||
|
– Poll_Window |
99 |
RCS-542 |
|||
|
– Timer_poll_periodic |
Not Present |
RCS-543 |
|||
|
– CHOICE Downlink RLC mode |
AM RLC |
RCS-544 |
|||
|
– CHOICE Downlink RLC PDU Size |
Reference to clause 6 Parameter Set |
RCS-545 |
|||
|
– Length indicator size |
7 |
RCS-546 |
|||
|
– In-sequence delivery |
TRUE |
RCS-547 |
|||
|
– Receiving window size |
32 |
RCS-548 |
|||
|
– Downlink RLC status info |
RCS-549 |
||||
|
– Timer_status_prohibit |
200 |
RCS-550 |
|||
|
– Timer_EPC |
Not Present |
RCS-551 |
|||
|
– Missing PDU indicator |
TRUE |
RCS-552 |
|||
|
– Timer_STATUS_periodic |
Not Present |
RCS-553 |
|||
|
– Alternative E-bit interpretation |
Not Present |
RCS-554 |
|||
|
– Use special value of HE field |
Not Present |
RCS-555 |
|||
|
– RB mapping info |
RCS-556 |
||||
|
– Information for each multiplexing option |
1 RBMuxOption |
RCS-557 |
|||
|
– RLC logical channel mapping indicator |
Not Present |
RCS-558 |
|||
|
– Number of RLC logical channels |
1 |
RCS-559 |
|||
|
– Uplink transport channel type |
RACH |
RCS-560 |
|||
|
– UL Transport channel identity |
Not Present |
RCS-561 |
|||
|
– Logical channel identity |
3 |
RCS-562 |
|||
|
– CHOICE RLC size list |
Explicit List |
RCS-563 |
|||
|
– RLC size index |
According to clause 6.10.2.4.4.1 (combinations on PRACH) |
RCS-564 |
|||
|
– MAC logical channel priority |
3 |
RCS-565 |
|||
|
– Downlink RLC logical channel info |
RCS-566 |
||||
|
– Number of RLC logical channels |
1 |
RCS-567 |
|||
|
– Downlink transport channel type |
HS-DSCH |
RCS-568 |
|||
|
– DL DCH Transport channel identity |
Not Present |
RCS-569 |
|||
|
– DL DSCH Transport channel identity |
Not Present |
RCS-570 |
|||
|
– CHOICE DL MAC header type |
MAC-ehs |
RCS-571 |
|||
|
– DL HS-DSCH MAC-ehs Queue Id |
1 |
RCS-572 |
|||
|
– Logical channel identity |
3 |
RCS-573 |
|||
|
– Signalling RB information to setup |
A1 |
(AM DCCH for NAS_DT Low priority) |
RCS-574 |
||
|
– RB identity |
Not Present |
RCS-575 |
|||
|
– CHOICE RLC info type |
RCS-576 |
||||
|
– RLC info |
RCS-577 |
||||
|
– CHOICE Uplink RLC mode |
AM RLC |
RCS-578 |
|||
|
– Transmission RLC discard |
RCS-579 |
||||
|
– SDU discard mode |
No discard |
RCS-580 |
|||
|
– MAX_DAT |
15 |
RCS-581 |
|||
|
– Transmission window size |
32 |
RCS-582 |
|||
|
– Timer_RST |
500 |
RCS-583 |
|||
|
– Max_RST |
1 |
RCS-584 |
|||
|
– Polling info |
RCS-585 |
||||
|
– Timer_poll_prohibit |
200 |
RCS-586 |
|||
|
– Timer_poll |
200 |
RCS-587 |
|||
|
– Poll_PDU |
Not present |
RCS-588 |
|||
|
– Poll_SDU |
1 |
RCS-589 |
|||
|
– Last transmission PDU poll |
TRUE |
RCS-590 |
|||
|
– Last retransmission PDU poll |
TRUE |
RCS-591 |
|||
|
– Poll_Window |
99 |
RCS-592 |
|||
|
– Timer_poll_periodic |
Not Present |
RCS-593 |
|||
|
– CHOICE Downlink RLC mode |
AM RLC |
RCS-594 |
|||
|
– DL RLC PDU size |
According to clause 6.10.2.4.1.3 (standalone 13.6 kbps signalling radio bearer) |
Rel-6 |
RCS-595 |
||
|
– In-sequence delivery |
TRUE |
RCS-596 |
|||
|
– Receiving window size |
32 |
RCS-597 |
|||
|
– Downlink RLC status info |
RCS-598 |
||||
|
– Timer_status_prohibit |
200 |
RCS-599 |
|||
|
– Timer_EPC |
Not Present |
RCS-600 |
|||
|
– Missing PDU indicator |
TRUE |
RCS-601 |
|||
|
– Timer_STATUS_periodic |
Not Present |
RCS-602 |
|||
|
– RB mapping info |
RCS-603 |
||||
|
– Information for each multiplexing option |
2 RBMuxOptions |
RCS-604 |
|||
|
– RLC logical channel mapping indicator |
Not Present |
RCS-605 |
|||
|
– Number of RLC logical channels |
1 |
RCS-606 |
|||
|
– Uplink transport channel type |
DCH |
RCS-607 |
|||
|
– UL Transport channel identity |
5 |
RCS-608 |
|||
|
– Logical channel identity |
4 |
RCS-609 |
|||
|
– CHOICE RLC size list |
Configured |
RCS-610 |
|||
|
– MAC logical channel priority |
4 |
RCS-611 |
|||
|
– Downlink RLC logical channel info |
RCS-612 |
||||
|
– Number of RLC logical channels |
1 |
RCS-613 |
|||
|
– Downlink transport channel type |
DCH |
RCS-614 |
|||
|
– DL DCH Transport channel identity |
10 |
RCS-615 |
|||
|
– DL DSCH Transport channel identity |
Not Present |
RCS-616 |
|||
|
– Logical channel identity |
4 |
RCS-617 |
|||
|
– RLC logical channel mapping indicator |
Not Present |
RCS-618 |
|||
|
– Number of RLC logical channels |
1 |
RCS-619 |
|||
|
– Uplink transport channel type |
RACH |
RCS-620 |
|||
|
– UL Transport channel identity |
Not Present |
RCS-621 |
|||
|
– Logical channel identity |
4 |
RCS-622 |
|||
|
– CHOICE RLC size list |
Explicit List |
RCS-623 |
|||
|
– RLC size index |
According to clause 6.10.2.4.1.3 (standalone 13.6 kbps signalling radio bearer) |
RCS-624 |
|||
|
– MAC logical channel priority |
4 |
RCS-625 |
|||
|
– Downlink RLC logical channel info |
RCS-626 |
||||
|
– Number of RLC logical channels |
1 |
RCS-627 |
|||
|
– Downlink transport channel type |
FACH |
RCS-628 |
|||
|
– DL DCH Transport channel identity |
Not Present |
RCS-629 |
|||
|
– DL DSCH Transport channel identity |
Not Present |
RCS-630 |
|||
|
– Logical channel identity |
4 |
RCS-631 |
|||
|
– Signalling RB information to setup |
A2 |
(AM DCCH for NAS_DT Low priority) |
Rel-6 |
RCS-632 |
|
|
– RB identity |
Not Present |
RCS-633 |
|||
|
– CHOICE RLC info type |
RCS-634 |
||||
|
– RLC info |
RCS-635 |
||||
|
– CHOICE Uplink RLC mode |
AM RLC |
RCS-636 |
|||
|
– Transmission RLC discard |
RCS-637 |
||||
|
– SDU discard mode |
No discard |
RCS-638 |
|||
|
– MAX_DAT |
15 |
RCS-639 |
|||
|
– Transmission window size |
32 |
RCS-640 |
|||
|
– Timer_RST |
500 |
RCS-641 |
|||
|
– Max_RST |
1 |
RCS-642 |
|||
|
– Polling info |
RCS-643 |
||||
|
– Timer_poll_prohibit |
200 |
RCS-644 |
|||
|
– Timer_poll |
200 |
RCS-645 |
|||
|
– Poll_PDU |
Not present |
RCS-646 |
|||
|
– Poll_SDU |
1 |
RCS-647 |
|||
|
– Last transmission PDU poll |
TRUE |
RCS-648 |
|||
|
– Last retransmission PDU poll |
TRUE |
RCS-649 |
|||
|
– Poll_Window |
99 |
RCS-650 |
|||
|
– Timer_poll_periodic |
Not Present |
RCS-651 |
|||
|
– CHOICE Downlink RLC mode |
AM RLC |
RCS-652 |
|||
|
– In-sequence delivery |
TRUE |
RCS-653 |
|||
|
– Receiving window size |
32 |
RCS-654 |
|||
|
– Downlink RLC status info |
RCS-655 |
||||
|
– Timer_status_prohibit |
200 |
RCS-656 |
|||
|
– Timer_EPC |
Not Present |
RCS-657 |
|||
|
– Missing PDU indicator |
TRUE |
RCS-658 |
|||
|
– Timer_STATUS_periodic |
Not Present |
RCS-659 |
|||
|
– RB mapping info |
RCS-660 |
||||
|
– Information for each multiplexing option |
1 RBMuxOption |
RCS-661 |
|||
|
– RLC logical channel mapping indicator |
Not Present |
RCS-662 |
|||
|
– Number of RLC logical channels |
1 |
RCS-663 |
|||
|
– Uplink transport channel type |
E-DCH |
RCS-664 |
|||
|
– Logical channel identity |
4 |
RCS-665 |
|||
|
– E-DCH MAC-d flow identity |
1 |
RCS-666 |
|||
|
– DDI |
4 |
RCS-667 |
|||
|
– RLC PDU size list |
1 RLC PDU size |
RCS-668 |
|||
|
– RLC PDU size |
144 bits |
RCS-669 |
|||
|
– Include in scheduling info |
FALSE |
RCS-670 |
|||
|
– MAC logical channel priority |
4 |
RCS-671 |
|||
|
– Downlink RLC logical channel info |
RCS-672 |
||||
|
– Number of RLC logical channels |
1 |
RCS-673 |
|||
|
– Downlink transport channel type |
HS-DSCH |
RCS-674 |
|||
|
– DL DCH Transport channel identity |
Not Present |
RCS-675 |
|||
|
– DL DSCH Transport channel identity |
Not Present |
RCS-676 |
|||
|
– DL HS-DSCH MAC-d flow identity |
1 |
RCS-677 |
|||
|
– Logical channel identity |
4 |
RCS-678 |
|||
|
– Signalling RB information to setup |
A3, A5 |
(AM DCCH for NAS DT Low priority) |
Rel-7 |
RCS-679 |
|
|
, A6 |
Rel-8 |
||||
|
– RB identity |
Not present |
RCS-680 |
|||
|
– CHOICE RLC info type |
RCS-681 |
||||
|
– RLC info |
RCS-682 |
||||
|
– CHOICE Uplink RLC mode |
AM RLC |
RCS-683 |
|||
|
– Transmission RLC discard |
RCS-684 |
||||
|
– SDU discard mode |
No discard |
RCS-685 |
|||
|
– MAX_DAT |
15 |
RCS-686 |
|||
|
– Transmission window size |
32 |
RCS-687 |
|||
|
– Timer_RST |
500 |
RCS-688 |
|||
|
– Max_RST |
1 |
RCS-689 |
|||
|
– Polling info |
RCS-690 |
||||
|
– Timer_poll_prohibit |
200 |
RCS-691 |
|||
|
– Timer_poll |
200 |
RCS-692 |
|||
|
– Poll_PDU |
Not Present |
RCS-693 |
|||
|
– Poll_SDU |
1 |
RCS-694 |
|||
|
– Last transmission PDU poll |
TRUE |
RCS-695 |
|||
|
– Last retransmission PDU poll |
TRUE |
RCS-696 |
|||
|
– Poll_Window |
99 |
RCS-697 |
|||
|
– Timer_poll_periodic |
Not Present |
RCS-698 |
|||
|
– CHOICE Downlink RLC mode |
AM RLC |
RCS-699 |
|||
|
– CHOICE Downlink RLC PDU Size |
Reference to clause 6 Parameter Set |
RCS-700 |
|||
|
– Length indicator size |
7 |
RCS-701 |
|||
|
– In-sequence delivery |
TRUE |
RCS-702 |
|||
|
– Receiving window size |
32 |
RCS-703 |
|||
|
– Downlink RLC status info |
RCS-704 |
||||
|
– Timer_status_prohibit |
200 |
RCS-705 |
|||
|
– Timer_EPC |
Not Present |
RCS-706 |
|||
|
– Missing PDU indicator |
TRUE |
RCS-707 |
|||
|
– Timer_STATUS_periodic |
Not Present |
RCS-708 |
|||
|
– Alternative E-bit interpretation |
Not Present |
RCS-709 |
|||
|
– Use special value of HE field |
TRUE |
RCS-710 |
|||
|
– RB mapping info |
RCS-711 |
||||
|
– Information for each multiplexing option |
1 RBMuxOption |
RCS-712 |
|||
|
– RLC logical channel mapping indicator |
Not Present |
RCS-713 |
|||
|
– Number of RLC logical channels |
1 |
RCS-714 |
|||
|
– Uplink transport channel type |
E-DCH |
RCS-715 |
|||
|
– Logical channel identity |
4 |
RCS-716 |
|||
|
– E-DCH MAC-d flow identity |
1 |
RCS-717 |
|||
|
– CHOICE RLC PDU size |
Fixed size |
Rel-8 |
RCS-718 |
||
|
– DDI |
2 |
RCS-719 |
|||
|
– RLC PDU size list |
1 RLC PDU size |
RCS-720 |
|||
|
– RLC PDU size |
144 bits |
RCS-721 |
|||
|
– Include in scheduling info |
FALSE |
RCS-722 |
|||
|
– MAC logical channel priority |
4 |
RCS-723 |
|||
|
– Downlink RLC logical channel info |
RCS-724 |
||||
|
– Number of RLC logical channels |
1 |
RCS-725 |
|||
|
– Downlink transport channel type |
HS-DSCH |
RCS-726 |
|||
|
– DL DCH Transport channel identity |
Not Present |
RCS-727 |
|||
|
– DL DSCH Transport channel identity |
Not Present |
RCS-728 |
|||
|
– CHOICE DL MAC header type |
MAC-ehs |
RCS-729 |
|||
|
– DL HS-DSCH MAC-ehs Queue Id |
1 |
RCS-730 |
|||
|
– Logical channel identity |
4 |
RCS-731 |
|||
|
– Signalling RB information to setup |
A4 |
(AM DCCH for NAS DT Low priority) |
Rel-7 |
RCS-732 |
|
|
– RB identity |
Not present |
RCS-733 |
|||
|
– CHOICE RLC info type |
RCS-734 |
||||
|
– RLC info |
RCS-735 |
||||
|
– CHOICE Uplink RLC mode |
AM RLC |
RCS-736 |
|||
|
– Transmission RLC discard |
RCS-737 |
||||
|
– SDU discard mode |
No discard |
RCS-738 |
|||
|
– MAX_DAT |
15 |
RCS-739 |
|||
|
– Transmission window size |
32 |
RCS-740 |
|||
|
– Timer_RST |
500 |
RCS-741 |
|||
|
– Max_RST |
1 |
RCS-742 |
|||
|
– Polling info |
RCS-743 |
||||
|
– Timer_poll_prohibit |
200 |
RCS-744 |
|||
|
– Timer_poll |
200 |
RCS-745 |
|||
|
– Poll_PDU |
Not Present |
RCS-746 |
|||
|
– Poll_SDU |
1 |
RCS-747 |
|||
|
– Last transmission PDU poll |
TRUE |
RCS-748 |
|||
|
– Last retransmission PDU poll |
TRUE |
RCS-749 |
|||
|
– Poll_Window |
99 |
RCS-750 |
|||
|
– Timer_poll_periodic |
Not Present |
RCS-751 |
|||
|
– CHOICE Downlink RLC mode |
AM RLC |
RCS-752 |
|||
|
– CHOICE Downlink RLC PDU Size |
Reference to clause 6 Parameter Set |
RCS-753 |
|||
|
– Length indicator size |
7 |
RCS-754 |
|||
|
– In-sequence delivery |
TRUE |
RCS-755 |
|||
|
– Receiving window size |
32 |
RCS-756 |
|||
|
– Downlink RLC status info |
RCS-757 |
||||
|
– Timer_status_prohibit |
200 |
RCS-758 |
|||
|
– Timer_EPC |
Not Present |
RCS-759 |
|||
|
– Missing PDU indicator |
TRUE |
RCS-760 |
|||
|
– Timer_STATUS_periodic |
Not Present |
RCS-761 |
|||
|
– Alternative E-bit interpretation |
Not Present |
RCS-762 |
|||
|
– Use special value of HE field |
Not Present |
RCS-763 |
|||
|
– RB mapping info |
RCS-764 |
||||
|
– Information for each multiplexing option |
1 RBMuxOption |
RCS-765 |
|||
|
– RLC logical channel mapping indicator |
Not Present |
RCS-766 |
|||
|
– Number of RLC logical channels |
1 |
RCS-767 |
|||
|
– Uplink transport channel type |
RACH |
RCS-768 |
|||
|
– UL Transport channel identity |
Not Present |
RCS-769 |
|||
|
– Logical channel identity |
4 |
RCS-770 |
|||
|
– CHOICE RLC size list |
Explicit List |
RCS-771 |
|||
|
– RLC size index |
According to clause 6.10.2.4.4.1 (Combinations on PRACH) |
RCS-772 |
|||
|
– MAC logical channel priority |
4 |
RCS-773 |
|||
|
– Downlink RLC logical channel info |
RCS-774 |
||||
|
– Number of RLC logical channels |
1 |
RCS-775 |
|||
|
– Downlink transport channel type |
HS-DSCH |
RCS-776 |
|||
|
– DL DCH Transport channel identity |
Not Present |
RCS-777 |
|||
|
– DL DSCH Transport channel identity |
Not Present |
RCS-778 |
|||
|
– CHOICE DL MAC header type |
MAC-ehs |
RCS-779 |
|||
|
– DL HS-DSCH MAC-ehs Queue Id |
1 |
RCS-780 |
|||
|
– Logical channel identity |
4 |
RCS-781 |
|||
|
UL Transport channel information for all transport channels |
A1 |
RCS-782 |
|||
|
– PRACH TFCS |
Not Present |
RCS-783 |
|||
|
– CHOICE Mode |
FDD |
RCS-784 |
|||
|
– TFC subset |
Nor Present |
RCS-785 |
|||
|
– UL DCH TFCS |
RCS-786 |
||||
|
– CHOICE TFCI signalling |
Normal |
RCS-787 |
|||
|
– TFCI Field 1 information |
RCS-788 |
||||
|
– CHOICE TFCS representation |
Complete |
RCS-789 |
|||
|
– TFCS complete reconfigure |
RCS-790 |
||||
|
– CHOICE CTFC Size |
2bit CTFC |
RCS-791 |
|||
|
– CTFC information |
This IE is repeated for TFC numbers according to clause 6.10.2.4.1.3 (standalone 13.6 kbps signalling radio bearer) |
RCS-792 |
|||
|
– CTFC |
According to clause 6.10.2.4.1.3 (standalone 13.6 kbps signalling radio bearer) |
RCS-793 |
|||
|
– Power offset information |
RCS-794 |
||||
|
– CHOICE Gain Factors |
Computed Gain Factors (The last TFC is set to Signalled Gain Factors) |
RCS-795 |
|||
|
– Gain factor ßc |
11 (below 64 kbps) 9 (higher than 64 kbps) (Not Present if the above is set to Computed Gain Factors) |
RCS-796 |
|||
|
– Gain factor ßd |
15 (Not Present if the above is set to Computed Gain Factors) |
RCS-797 |
|||
|
– Reference TFC ID |
0 |
RCS-798 |
|||
|
– CHOICE mode |
FDD |
RCS-799 |
|||
|
– Power offset Pp-m |
Not Present |
RCS-800 |
|||
|
UL Transport channel information for all transport channels |
A2 |
Not Present |
Rel-6 |
RCS-801 |
|
|
UL Transport channel information for all transport channels |
A3, A4 |
Not Present |
Rel-7 |
RCS-802 |
|
|
A5, A6 |
Rel-8 |
RCS-803 |
|||
|
Added or Reconfigured UL TrCH information |
A1 |
RCS-804 |
|||
|
– Uplink transport channel type |
DCH |
RCS-805 |
|||
|
– UL Transport channel identity |
5 |
RCS-806 |
|||
|
– TFS |
RCS-807 |
||||
|
– CHOICE Transport channel type |
Dedicated transport channels |
RCS-808 |
|||
|
– Dynamic Transport format information |
RCS-809 |
||||
|
– RLC size |
According to clause 6.10.2.4.1.3 (standalone 13.6 kbps signalling radio bearer) |
RCS-810 |
|||
|
– Number of TBs and TTI lists |
(This IE is repeated for TFI number) |
RCS-811 |
|||
|
– Transmission Time Interval |
According to clause 6.10.2.4.1.3 (standalone 13.6 kbps signalling radio bearer) |
RCS-812 |
|||
|
– Number of Transport blocks |
According to clause 6.10.2.4.1.3 (standalone 13.6 kbps signalling radio bearer) |
RCS-813 |
|||
|
– CHOICE Logical channel list |
All |
RCS-814 |
|||
|
– Semi-static Transport Format information |
RCS-815 |
||||
|
– Transmission time interval |
According to clause 6.10.2.4.1.3 (standalone 13.6 kbps signalling radio bearer) |
RCS-816 |
|||
|
– Type of channel coding |
According to clause 6.10.2.4.1.3 (standalone 13.6 kbps signalling radio bearer) |
RCS-817 |
|||
|
– Coding Rate |
According to clause 6.10.2.4.1.3 (standalone 13.6 kbps signalling radio bearer) |
RCS-818 |
|||
|
– Rate matching attribute |
According to clause 6.10.2.4.1.3 (standalone 13.6 kbps signalling radio bearer) |
RCS-819 |
|||
|
– CRC size |
According to clause 6.10.2.4.1.3 (standalone 13.6 kbps signalling radio bearer) |
RCS-820 |
|||
|
Added or Reconfigured UL TrCH information |
A2 |
1 E-DCH added with one DCCH MAC-d flow |
Rel-6 |
RCS-821 |
|
|
A3 |
Rel-7 |
RCS-822 |
|||
|
– Uplink transport channel type |
E-DCH |
RCS-823 |
|||
|
– CHOICE UL parameters |
E-DCH |
RCS-824 |
|||
|
– E-DCH Transmission Time Interval |
set to 2ms if supported by the UE E-DCH category, or 10ms if the UE E-DCH category does not support 2ms TTI |
RCS-825 |
|||
|
– HARQ info for E-DCH |
RCS-826 |
||||
|
– HARQ RV Configuration |
rvtable |
RCS-827 |
|||
|
– Added or reconfigured E-DCH MAC-d flow |
(for DCCH) |
RCS-828 |
|||
|
– E-DCH MAC-d flow identity |
1 |
RCS-829 |
|||
|
– E-DCH MAC-d flow power offset |
0 |
RCS-830 |
|||
|
– E-DCH MAC-d flow maximum number of retransmissions |
7 |
RCS-831 |
|||
|
– E-DCH MAC-d flow multiplexing list |
Not Present |
RCS-832 |
|||
|
– CHOICE transmission grant type |
Non-scheduled grant info |
RCS-833 |
|||
|
– Max MAC-e PDU contents size |
162 bits |
RCS-834 |
|||
|
– 2 ms non-scheduled transmission grant HARQ process allocation |
Not Present |
RCS-835 |
|||
|
Added or Reconfigured UL TrCH information |
A4 |
Not Present |
Rel-7 |
RCS-836 |
|
|
Added or Reconfigured UL TrCH information |
A5, A6 |
1 E-DCH added with one DCCH MAC-d flow |
Rel-8 |
RCS-837 |
|
|
– Uplink transport channel type |
E-DCH |
RCS-838 |
|||
|
– CHOICE UL parameters |
E-DCH |
RCS-839 |
|||
|
– UL MAC header type |
MAC-i/is |
RCS-840 |
|||
|
– E-DCH Transmission Time Interval |
set to 2ms if supported by the UE E-DCH category, or 10ms if the UE E-DCH category does not support 2ms TTI |
RCS-841 |
|||
|
– HARQ info for E-DCH |
RCS-842 |
||||
|
– HARQ RV Configuration |
rvtable |
RCS-843 |
|||
|
– Added or reconfigured E-DCH MAC-d flow |
(for DCCH) |
RCS-844 |
|||
|
– E-DCH MAC-d flow identity |
1 |
RCS-845 |
|||
|
– E-DCH MAC-d flow power offset |
0 |
RCS-846 |
|||
|
– E-DCH MAC-d flow maximum number of retransmissions |
7 |
RCS-847 |
|||
|
– E-DCH MAC-d flow multiplexing list |
Not Present |
RCS-848 |
|||
|
– CHOICE transmission grant type |
Non-scheduled grant info |
RCS-849 |
|||
|
– Max MAC-e PDU contents size |
168 bits |
RCS-850 |
|||
|
– 2 ms non-scheduled transmission grant HARQ process allocation |
Not Present |
RCS-851 |
|||
|
DL Transport channel information common for all transport channel |
A1 |
RCS-852 |
|||
|
– SCCPCH TFCS |
Not Present |
RCS-853 |
|||
|
– CHOICE mode |
FDD |
RCS-854 |
|||
|
– CHOICE DL parameters |
Same as UL |
RCS-855 |
|||
|
DL Transport channel information common for all transport channel |
A2 |
Not Present |
Rel-6 |
RCS-856 |
|
|
DL Transport channel information common for all transport channel |
A3, A4 |
Not Present |
Rel-7 |
RCS-857 |
|
|
A5, A6 |
Rel-8 |
RCS-858 |
|||
|
Added or Reconfigured DL TrCH information |
A1 |
RCS-859 |
|||
|
– Downlink transport channel type |
DCH |
RCS-860 |
|||
|
– DL Transport channel identity |
10 |
RCS-861 |
|||
|
– CHOICE DL parameters |
Same as UL |
RCS-862 |
|||
|
– Uplink transport channel type |
DCH |
RCS-863 |
|||
|
– UL TrCH Identity |
5 |
RCS-864 |
|||
|
– DCH quality target |
RCS-865 |
||||
|
– BLER Quality value |
-20 (-2.0) |
RCS-866 |
|||
|
Added or Reconfigured DL TrCH information |
A2 |
1 TrCH (HS-DSCH for DCCH) |
Rel-6 |
RCS-867 |
|
|
– Downlink transport channel type |
HS-DSCH |
RCS-868 |
|||
|
– DL Transport channel identity |
Not Present |
RCS-869 |
|||
|
– CHOICE DL parameters |
HS-DSCH |
RCS-870 |
|||
|
– HARQ Info |
RCS-871 |
||||
|
– Number of Processes |
Reference to clause 6.10.2.4.5 Parameter Set |
RCS-872 |
|||
|
– CHOICE Memory Partitioning |
Implicit |
RCS-873 |
|||
|
– Added or reconfigured MAC-d flow |
RCS-874 |
||||
|
– MAC-hs queue to add or reconfigure list |
(one queue) |
RCS-875 |
|||
|
– MAC-hs queue Id |
1 (for DCCH) |
RCS-876 |
|||
|
– MAC-d Flow Identity |
1 |
RCS-877 |
|||
|
– T1 |
50 |
RCS-878 |
|||
|
– MAC-hs window size |
16 |
RCS-879 |
|||
|
– MAC-d PDU size Info |
RCS-880 |
||||
|
– MAC-d PDU size |
148 |
RCS-881 |
|||
|
– MAC-d PDU size index |
0 |
RCS-882 |
|||
|
– MAC-hs queue to delete list |
Not present |
RCS-883 |
|||
|
– DCH quality target |
Not present |
RCS-884 |
|||
|
Added or Reconfigured DL TrCH information |
A3 |
1 TrCH (HS-DSCH for DCCH) |
Rel-7 |
RCS-885 |
|
|
A5 A4 A6 |
Rel-8 Rel-7 Rel-8 |
RCS-886 |
|||
|
– Downlink transport channel type |
HS-DSCH |
RCS-887 |
|||
|
– DL Transport channel identity |
Not Present |
RCS-888 |
|||
|
– CHOICE DL parameters |
HS-DSCH |
RCS-889 |
|||
|
– HARQ Info |
RCS-890 |
||||
|
– Number of Processes |
Reference to clause 6.10.2.4.5 Parameter Set |
RCS-891 |
|||
|
– CHOICE Memory Partitioning |
Implicit |
RCS-892 |
|||
|
– CHOICE DL MAC header type |
MAC-ehs |
RCS-893 |
|||
|
– Added or reconfigured MAC-ehs reordering queue |
RCS-894 |
||||
|
– MAC-ehs queue to add or reconfigure list |
(1 queue) |
RCS-895 |
|||
|
– MAC-ehs queue Id |
1 |
RCS-896 |
|||
|
– T1 |
50 |
RCS-897 |
|||
|
– MAC-ehs window size |
16 |
RCS-898 |
|||
|
– MAC-ehs queue to delete list |
Not present |
RCS-899 |
|||
|
– DCH quality target |
Not present |
RCS-900 |
|||
|
Frequency info |
Not Present |
RCS-901 |
|||
|
DTX-DRX timing information |
Not present |
Rel-7 |
RCS-902 |
||
|
DTX-DRX Information |
Not present |
Rel-7 |
RCS-903 |
||
|
HS-SCCH less Information |
Not present |
Rel-7 |
RCS-904 |
||
|
Maximum allowed UL TX power |
Not Present |
RCS-905 |
|||
|
Uplink DPCH info |
A1 |
RCS-907 |
|||
|
– Uplink DPCH power control info |
RCS-908 |
||||
|
– DPCCH power offset |
-40 (-80dB) |
RCS-909 |
|||
|
– PC Preamble |
1 frame |
RCS-910 |
|||
|
– SRB delay |
7 frames |
RCS-911 |
|||
|
– Power Control Algorithm |
Algorithm1 |
RCS-912 |
|||
|
– TPC step size |
0 (1dB) |
RCS-913 |
|||
|
– Scrambling code type |
Long |
RCS-914 |
|||
|
– Scrambling code number |
0 (0 to 16777215) |
RCS-915 |
|||
|
– Number of DPDCH |
Not Present(1) |
RCS-916 |
|||
|
– Spreading factor |
According to clause 6.10.2.4.1.3 (standalone 13.6 kbps signalling radio bearer) |
RCS-917 |
|||
|
– TFCI existence |
According to clause 6.10.2.4.1.3 (standalone 13.6 kbps signalling radio bearer) |
RCS-918 |
|||
|
– Number of FBI bit |
According to clause 6.10.2.4.1.3 (standalone 13.6 kbps signalling radio bearer) |
RCS-919 |
|||
|
– Puncturing Limit |
According to clause 6.10.2.4.1.3 (standalone 13.6 kbps signalling radio bearer) |
RCS-920 |
|||
|
– Number of TPC bits |
Not present |
Rel-7 |
RCS-921 |
||
|
Uplink DPCH info |
A2 |
Rel-6 |
RCS-922 |
||
|
A3 |
Rel-7 |
RCS-923 |
|||
|
A5 |
Rel-8 |
RCS-924 |
|||
|
– Uplink DPCH power control info |
RCS-925 |
||||
|
– DPCCH power offset |
-40 (-80dB) |
RCS-926 |
|||
|
– PC Preamble |
1 frame |
RCS-927 |
|||
|
– SRB delay |
7 frames |
RCS-928 |
|||
|
– Power Control Algorithm |
Algorithm1 |
RCS-929 |
|||
|
– TPC step size |
0 (1dB) |
RCS-930 |
|||
|
– ACK |
3 |
RCS-931 |
|||
|
– NACK |
3 |
RCS-932 |
|||
|
– Ack-Nack repetition factor |
1 |
RCS-933 |
|||
|
– HARQ_preamble_mode |
0 |
RCS-934 |
|||
|
– Scrambling code type |
Long |
RCS-935 |
|||
|
– Scrambling code number |
0 (0 to 16777215) |
RCS-936 |
|||
|
– Number of DPDCH |
0 |
RCS-937 |
|||
|
– spreading factor |
Not Present |
RCS-938 |
|||
|
– TFCI existence |
FALSE |
RCS-939 |
|||
|
– Number of FBI bit |
Not Present |
RCS-940 |
|||
|
– Puncturing Limit |
Not Present |
RCS-941 |
|||
|
Uplink DPCH info |
A4 |
Not Present |
Rel-7 |
RCS-942 |
|
|
A6 |
Rel-8 |
||||
|
E-DCH Info |
A1 |
Not Present |
Rel-6 |
RCS-943 |
|
|
E-DCH info |
A2 |
Rel-6 |
RCS-944 |
||
|
A3 |
Rel-7 |
RCS-945 |
|||
|
A5 |
Rel-8 |
RCS-946 |
|||
|
– MAC-es/e reset indicator |
TRUE |
RCS-947 |
|||
|
– E-DPCCH info |
RCS-948 |
||||
|
– E-DPCCH/DPCCH power offset |
0 |
RCS-949 |
|||
|
– Happy bit delay condition |
100 ms |
RCS-950 |
|||
|
– E-TFC Boost Info |
Not present |
Rel-7 |
RCS-951 |
||
|
– E-DPDCH power interpolation |
Not present |
Rel-7 |
RCS-952 |
||
|
– E-DPDCH info |
RCS-953 |
||||
|
– E-TFCI table index |
0 |
RCS-954 |
|||
|
– E-DCH minimum set E-TFCI |
9 |
RCS-955 |
|||
|
– Reference E-TFCIs |
2 E-TFCIs |
RCS-956 |
|||
|
– Reference E-TFCI |
11 |
RCS-957 |
|||
|
– Reference E-TFCI PO |
4 |
RCS-958 |
|||
|
– Reference E-TFCI |
83 |
RCS-959 |
|||
|
– Reference E-TFCI PO |
16 |
RCS-960 |
|||
|
– Maximum channelisation codes |
2sf4 |
RCS-961 |
|||
|
– PLnon-max |
0.84 |
RCS-962 |
|||
|
– Scheduling Information Configuration |
RCS-963 |
||||
|
– Periodicity for Scheduling Info – no grant |
Not present |
RCS-964 |
|||
|
– Periodicity for Scheduling Info – grant |
Not present |
RCS-965 |
|||
|
– Power Offset for Scheduling Info |
0 |
RCS-966 |
|||
|
– 3-Index-Step Threshold |
Not present |
RCS-967 |
|||
|
– 2-Index-Step Threshold |
Not present |
RCS-968 |
|||
|
– Scheduled Transmission configuration |
RCS-969 |
||||
|
– 2ms scheduled transmission grant HARQ process allocation |
Not present |
RCS-970 |
|||
|
– Serving Grant |
Not present |
RCS-971 |
|||
|
– UL 16QAM settings |
Not present |
Rel-7 |
RCS-972 |
||
|
E-DCH info |
A4 |
Not Present |
Rel-7 |
RCS-973 |
|
|
A6 |
Rel-8 |
||||
|
Downlink HS-PDSCH Information |
A1 |
Not Present |
Rel-6 |
RCS-974 |
|
|
Downlink HS-PDSCH Information |
A2 |
Rel-6 |
RCS-975 |
||
|
A5, A6 |
Rel-8 |
RCS-976 |
|||
|
A3 |
Rel-7 |
RCS-977 |
|||
|
– HS-SCCH Info |
RCS-978 |
||||
|
– CHOICE mode |
FDD |
RCS-979 |
|||
|
– DL Scrambling Code |
Not present |
RCS-980 |
|||
|
– HS-SCCH Channelisation Code Information |
RCS-981 |
||||
|
– HS-SCCH Channelisation Code |
7 |
RCS-982 |
|||
|
– Measurement Feedback Info |
RCS-983 |
||||
|
– CHOICE mode |
FDD |
RCS-984 |
|||
|
– POhsdsch |
6 dB |
RCS-985 |
|||
|
– CQI Feedback cycle, k |
4 ms |
RCS-986 |
|||
|
– CQI repetition factor |
1 |
RCS-987 |
|||
|
– CQI |
5 (corresponds to 0dB in relative power offset) |
RCS-988 |
|||
|
– CHOICE mode |
FDD (no data) |
RCS-989 |
|||
|
– Downlink 64QAM configured |
Not present |
Rel-7 |
RCS-990 |
||
|
– HS-DSCH TB size table |
Not present |
Rel-7 |
RCS-991 |
||
|
Downlink HS-PDSCH Information |
A4 |
Not present |
Rel-7 |
RCS-992 |
|
|
Downlink information common for all radio links |
A1 |
RCS-993 |
|||
|
– Downlink DPCH info common for all RL |
RCS-994 |
||||
|
– Timing Indication |
Initialize |
RCS-995 |
|||
|
– CFN-targetSFN frame offset |
Not Present |
RCS-996 |
|||
|
– CHOICE mode |
FDD |
RCS-997 |
|||
|
– Downlink DPCH power control information |
RCS-998 |
||||
|
– DPC mode |
0 (single) |
RCS-999 |
|||
|
– Power offset P Pilot-DPDCH |
0 |
RCS-1000 |
|||
|
– DL rate matching restriction information |
Not Present |
RCS-1001 |
|||
|
– Spreading factor |
According to clause 6.10.2.4.1.3 (standalone 13.6 kbps signalling radio bearer) |
RCS-1002 |
|||
|
– Fixed or Flexible Position |
According to clause 6.10.2.4.1.3 (standalone 13.6 kbps signalling radio bearer) |
RCS-1003 |
|||
|
– TFCI existence |
According to clause 6.10.2.4.1.3 (standalone 13.6 kbps signalling radio bearer) |
RCS-1004 |
|||
|
– CHOICE SF |
According to clause 6.10.2.4.1.3 (standalone 13.6 kbps signalling radio bearer) |
RCS-1005 |
|||
|
– DPCH compressed mode info |
Not Present |
RCS-1006 |
|||
|
– TX Diversity mode |
None |
RCS-1007 |
|||
|
– SSDT information |
Not Present |
R99 and Rel-4 only |
RCS-1008 |
||
|
– Default DPCH Offset Value |
Arbitrary set to value 0..306688 by step of 512 |
RCS-1009 |
|||
|
Downlink information common for all radio links |
A2 |
Rel-6 |
RCS-1010 |
||
|
A3 |
Rel-7 |
RCS-1011 |
|||
|
A5 |
Rel-8 |
RCS-1012 |
|||
|
– Downlink F-DPCH info common for all RL |
RCS-1013 |
||||
|
– Timing Indication |
Initialise |
RCS-1014 |
|||
|
– Downlink F-DPCH power control information |
RCS-1015 |
||||
|
– DPC mode |
0 (single) |
RCS-1016 |
|||
|
– TPC command error rate target |
0.04 |
RCS-1017 |
|||
|
– CHOICE mode |
FDD |
RCS-1018 |
|||
|
– DPCH compressed mode info |
Not Present |
RCS-1019 |
|||
|
– TX Diversity mode |
None |
RCS-1020 |
|||
|
– Default DPCH Offset Value |
Arbitrary set to value 0..306688 by step of 512 |
RCS-1021 |
|||
|
– MAC-hs reset indicator |
TRUE |
RCS-1022 |
|||
|
Downlink information common for all radio links |
A4 |
Not Present |
Rel-7 |
RCS-1023 |
|
|
A6 |
Rel-8 |
||||
|
Downlink information for each radio links list |
A1 |
RCS-1024 |
|||
|
– Downlink information for each radio links |
RCS-1025 |
||||
|
– CHOICE mode |
FDD |
RCS-1026 |
|||
|
– Primary CPICH info |
RCS-1027 |
||||
|
– Primary scrambling code |
Reference to clause 6.1 "Default settings (FDD)" |
RCS-1028 |
|||
|
– PDSCH with SHO DCH info |
Not Present |
R99 and Rel-4 only |
RCS-1029 |
||
|
– PDSCH code mapping |
Not Present |
R99 and Rel-4 only |
RCS-1030 |
||
|
– Serving HS-DSCH radio link indicator |
FALSE |
Rel-6 |
RCS-1031 |
||
|
– Serving E-DCH radio link indicator |
FALSE |
Rel-6 |
RCS-1032 |
||
|
– Downlink DPCH info for each RL |
RCS-1033 |
||||
|
– Primary CPICH usage for channel estimation |
Primary CPICH may be used |
RCS-1034 |
|||
|
– DPCH frame offset |
Set to value: Default DPCH Offset Value mod 38 400 |
RCS-1035 |
|||
|
– Secondary CPICH info |
Not Present |
RCS-1036 |
|||
|
– DL channelisation code |
RCS-1037 |
||||
|
– Secondary scrambling code |
1 |
RCS-1038 |
|||
|
– Spreading factor |
According to clause 6.10.2.4.1.3 (standalone 13.6 kbps signalling radio bearer) |
RCS-1039 |
|||
|
– Code number |
0 |
RCS-1040 |
|||
|
– Scrambling code change |
Not Present |
RCS-1041 |
|||
|
– TPC combination index |
0 |
RCS-1042 |
|||
|
– SSDT Cell Identity |
Not Present |
R99 and Rel-4 only |
RCS-1043 |
||
|
– Closed loop timing adjustment mode |
Not Present |
RCS-1044 |
|||
|
– E-AGCH Info |
Not Present |
Rel-6 |
RCS-1045 |
||
|
– E-HICH Information |
Not Present |
Rel-6 |
RCS-1046 |
||
|
– E-RGCH Information |
Not Present |
Rel-6 |
RCS-1047 |
||
|
– SCCPCH information for FACH |
Not Present |
R99 and Rel-4 only |
RCS-1048 |
||
|
Downlink information for each radio link list |
A2 |
Rel-6 |
RCS-1049 |
||
|
A3 |
Rel-7 |
RCS-1050 |
|||
|
A5 |
Rel-8 |
RCS-1051 |
|||
|
– Downlink information for each radio link |
RCS-1052 |
||||
|
– Choice mode |
FDD |
RCS-1053 |
|||
|
– Primary CPICH info |
RCS-1054 |
||||
|
– Primary scrambling code |
Ref. to the Default setting in clause 6.1 (FDD) |
RCS-1055 |
|||
|
– Serving HS-DSCH radio link indicator |
TRUE |
RCS-1056 |
|||
|
– Serving E-DCH radio link indicator |
TRUE |
RCS-1057 |
|||
|
– Downlink DPCH info for each RL |
Not Present |
RCS-1058 |
|||
|
– Downlink F-DPCH info for each RL |
RCS-1059 |
||||
|
– Primary CPICH usage for channel estimation |
Primary CPICH may be used |
RCS-1060 |
|||
|
– F-DPCH frame offset |
Set to value Default DPCH Offset Value (as currently stored in SS) mod 38 400 |
RCS-1061 |
|||
|
– F-DPCH slot format |
Not Present |
Rel-7 |
RCS-1062 |
||
|
– Secondary CPICH info |
Not Present |
RCS-1063 |
|||
|
– Secondary scrambling code |
Not Present |
RCS-1064 |
|||
|
– Code number |
12 |
RCS-1065 |
|||
|
– TPC combination index |
0 |
RCS-1066 |
|||
|
– E-AGCH Info |
RCS-1067 |
||||
|
– E-AGCH Channelisation Code |
10 |
RCS-1068 |
|||
|
– CHOICE E-HICH Information |
RCS-1069 |
||||
|
– E-HICH Information |
RCS-1070 |
||||
|
– Channelisation code |
4 |
RCS-1071 |
|||
|
– Signature sequence |
1 |
RCS-1072 |
|||
|
– CHOICE E-RGCH Information |
RCS-1073 |
||||
|
– E-RGCH Information |
RCS-1074 |
||||
|
– Signature Sequence |
0 |
RCS-1075 |
|||
|
– RG combination index |
0 |
RCS-1076 |
|||
|
Downlink information for each radio link list |
A4 |
Not Present |
Rel-7 |
RCS-1077 |
|
|
A6 |
Rel-8 |
||||
|
Condition |
Explanation |
Version |
|
A1 |
This IE is needed for “Stand-alone SRBs mapped on DCH/DCH” |
|
|
A2 |
This IE is needed for "Stand-alone SRBs mapped on E-DCH and HS-DSCH " |
Rel-6 |
|
A3 |
This IE is needed for "Stand-alone SRBs mapped on E-DCH and HS-DSCH using MAC-ehs” |
Rel-7 |
|
A4 |
This IE is needed for "Stand-alone SRBs mapped on RACH and HS-DSCH using MAC-ehs” for HS-DSCH reception in CELL_FACH |
Rel-7 |
|
A5 |
This IE is needed for "Stand-alone SRBs mapped on E-DCH using MAC-i/is and HS-DSCH using MAC-ehs” |
Rel-8 |
|
A6 |
This IE is needed for SRB mapped onto common E-DCH (MAC-i/is) and HS-DSCH (MAC-ehs) in Enhanced CELL_FACH |
|
|
UTRAN to E-UTRA |
This IE is needed for UTRAN to E-UTRA test cases |
Rel-8 |
|
NOTE 1: If not specified, then A1 will be the default condition NOTE 2: E-UTRA capability is requested on the first RRC connection setup message during test case execution |
||
Contents of RRC CONNECTION SETUP message: UM (Transition to CELL_FACH)
|
Information Element |
Condition |
Value/remark |
Version |
Index |
||||
|---|---|---|---|---|---|---|---|---|
|
Message Type |
RCSU-001 |
|||||||
|
Initial UE identity |
Select the same identity as in the IE "Initial UE Identity" in received RRC CONNECTION REQUEST" message |
RCSU-002 |
||||||
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
RCSU-003 |
||||||
|
Activation time |
Not Present (Now) |
RCSU-004 |
||||||
|
New U-RNTI |
RCSU-005 |
|||||||
|
– SRNC identity |
0000 0000 0001B |
RCSU-006 |
||||||
|
– S-RNTI |
0000 0000 0000 0000 0001B |
RCSU-007 |
||||||
|
New C-RNTI |
0000 0000 0000 0001B |
RCSU-008 |
||||||
|
New H-RNTI |
Not present |
Rel-6 |
RCSU-009 |
|||||
|
New Primary E-RNTI |
Not present |
Rel-6 |
RCSU-010 |
|||||
|
New Secondary E-RNTI |
Not present |
Rel-6 |
RCSU-011 |
|||||
|
RRC state indicator |
CELL_FACH |
RCSU-012 |
||||||
|
UTRAN DRX cycle length coefficient |
9 |
RCSU-013 |
||||||
|
Capability update requirement |
RCSU-014 |
|||||||
|
– UE radio access FDD capability update requirement |
TRUE |
RCSU-015 |
||||||
|
– UE radio access TDD capability update requirement |
FALSE |
RCSU-016 |
||||||
|
– UE radio access 3.84 Mcps TDD capability update requirement |
FALSE |
Rel-4 |
RCSU-017 |
|||||
|
– UE radio access 1.28 Mcps TDD capability update requirement |
FALSE |
Rel-4 |
RCSU-018 |
|||||
|
– System specific capability update requirement list |
GSM |
RCSU-019 |
||||||
|
– System specific capability update requirement list |
UTRAN to E-UTRA |
GSM, EUTRA |
Rel-8 |
|||||
|
CHOICE specification mode |
Complete specification |
Rel-5 |
RCSU-020 |
|||||
|
– Complete specification |
Rel-5 |
RCSU-021 |
||||||
|
– Signalling RB information to setup |
(UM DCCH for RRC) |
RCSU-022 |
||||||
|
– RB identity |
Not present |
RCSU-023 |
||||||
|
– CHOICE RLC info type |
RLC info |
RCSU-024 |
||||||
|
– CHOICE Uplink RLC mode |
UM RLC |
RCSU-025 |
||||||
|
– Transmission RLC discard |
timerBasedNoExplicit : dt50 |
RCSU-026 |
||||||
|
– SDU discard mode |
Not present |
RCSU-027 |
||||||
|
– CHOICE Downlink RLC mode |
UM RLC |
RCSU-028 |
||||||
|
– DL UM RLC LI size |
7 bit |
Rel-6 |
RCSU-029 |
|||||
|
– One sided RLC re-establishment |
FALSE |
Rel-6 |
RCSU-030 |
|||||
|
– RB mapping info |
RCSU-031 |
|||||||
|
– Information for each multiplexing option |
2 RBMuxOptions |
RCSU-032 |
||||||
|
– RLC logical channel mapping indicator |
Not Present |
RCSU-033 |
||||||
|
– Number of uplink RLC logical channels |
1 |
RCSU-034 |
||||||
|
– Uplink transport channel type |
DCH |
RCSU-035 |
||||||
|
– UL Transport channel identity |
5 |
RCSU-036 |
||||||
|
– Logical channel identity |
1 |
RCSU-037 |
||||||
|
– CHOICE RLC size list |
Configured |
RCSU-038 |
||||||
|
– MAC logical channel priority |
1 |
RCSU-039 |
||||||
|
– Downlink RLC logical channel info |
RCSU-040 |
|||||||
|
– Number of downlink RLC logical channels |
1 |
RCSU-041 |
||||||
|
– Downlink transport channel type |
DCH |
RCSU-042 |
||||||
|
– DL DCH Transport channel identity |
10 |
RCSU-043 |
||||||
|
– DL DSCH Transport channel identity |
Not Present |
RCSU-044 |
||||||
|
– Logical channel identity |
1 |
RCSU-045 |
||||||
|
– RLC logical channel mapping indicator |
Not Present |
RCSU-046 |
||||||
|
– Number of uplink RLC logical channels |
1 |
RCSU-047 |
||||||
|
– Uplink transport channel type |
RACH |
RCSU-048 |
||||||
|
– UL Transport channel identity |
Not Present |
RCSU-049 |
||||||
|
– Logical channel identity |
1 |
RCSU-050 |
||||||
|
– CHOICE RLC size list |
Explicit list |
RCSU-051 |
||||||
|
– RLC size index |
According to clause 6.10.2.4.4.1 |
RCSU-052 |
||||||
|
– MAC logical channel priority |
1 |
RCSU-053 |
||||||
|
– Downlink RLC logical channel info |
RCSU-054 |
|||||||
|
– Number of downlink RLC logical channels |
1 |
RCSU-055 |
||||||
|
– Downlink transport channel type |
FACH |
RCSU-056 |
||||||
|
– DL DCH Transport channel identity |
Not Present |
RCSU-057 |
||||||
|
– DL DSCH Transport channel identity |
Not Present |
RCSU-058 |
||||||
|
– Logical channel identity |
1 |
RCSU-059 |
||||||
|
– Signalling RB information to setup |
(AM DCCH for RRC) |
RCSU-060 |
||||||
|
– RB identity |
Not Present |
RCSU-061 |
||||||
|
– CHOICE RLC info type |
RLC info |
RCSU-062 |
||||||
|
– CHOICE Uplink RLC mode |
AM RLC |
RCSU-063 |
||||||
|
– Transmission RLC discard |
RCSU-064 |
|||||||
|
– SDU discard mode |
No Discard |
RCSU-065 |
||||||
|
– MAX_DAT |
15 |
RCSU-066 |
||||||
|
– Transmission window size |
32 |
RCSU-067 |
||||||
|
– Timer_RST |
500 |
RCSU-068 |
||||||
|
– Max_RST |
1 |
RCSU-069 |
||||||
|
– Polling info |
RCSU-070 |
|||||||
|
– Timer_poll_prohibit |
200 |
RCSU-071 |
||||||
|
– Timer_poll |
200 |
RCSU-072 |
||||||
|
– Poll_PDU |
Not Present |
RCSU-073 |
||||||
|
– Poll_SDU |
1 |
RCSU-074 |
||||||
|
– Last transmission PDU poll |
TRUE |
RCSU-075 |
||||||
|
– Last retransmission PDU poll |
TRUE |
RCSU-076 |
||||||
|
– Poll_Windows |
99 |
RCSU-077 |
||||||
|
– Timer_poll_periodic |
Not Present |
RCSU-078 |
||||||
|
– CHOICE Downlink RLC mode |
AM RLC |
RCSU-079 |
||||||
|
– DL RLC PDU size |
According to clause 6.10.2.4.1.3 (standalone 13.6 kbps signalling radio bearer) |
Rel-6 |
RCSU-080 |
|||||
|
– In-sequence delivery |
TRUE |
RCSU-081 |
||||||
|
– Receiving window size |
32 |
RCSU-082 |
||||||
|
– Downlink RLC status info |
RCSU-083 |
|||||||
|
– Timer_status_prohibit |
200 |
RCSU-084 |
||||||
|
– Timer_EPC |
Not Present |
RCSU-085 |
||||||
|
– Missing PDU indicator |
TRUE |
RCSU-086 |
||||||
|
– Timer_STATUS_periodic |
Not Present |
RCSU-087 |
||||||
|
– RB mapping info |
RCSU-088 |
|||||||
|
– Information for each multiplexing option |
2 RBMuxOptions |
RCSU-089 |
||||||
|
– RLC logical channel mapping indicator |
Not Present |
RCSU-090 |
||||||
|
– Number of uplink RLC logical channels |
1 |
RCSU-091 |
||||||
|
– Uplink transport channel type |
DCH |
RCSU-092 |
||||||
|
– UL Transport channel identity |
5 |
RCSU-093 |
||||||
|
– Logical channel identity |
2 |
RCSU-094 |
||||||
|
– CHOICE RLC size list |
Configured |
RCSU-095 |
||||||
|
– MAC logical channel priority |
2 |
RCSU-096 |
||||||
|
– Downlink RLC logical channel info |
RCSU-097 |
|||||||
|
– Number of downlink RLC logical channels |
1 |
RCSU-098 |
||||||
|
– Downlink transport channel type |
DCH |
RCSU-099 |
||||||
|
– DL DCH Transport channel identity |
10 |
RCSU-100 |
||||||
|
– DL DSCH Transport channel identity |
Not Present |
RCSU-101 |
||||||
|
– Logical channel identity |
2 |
RCSU-102 |
||||||
|
– RLC logical channel mapping indicator |
Not Present |
RCSU-103 |
||||||
|
– Number of uplink RLC logical channels |
1 |
RCSU-104 |
||||||
|
– Uplink transport channel type |
RACH |
RCSU-105 |
||||||
|
– UL Transport channel identity |
Not Present |
RCSU-106 |
||||||
|
– Logical channel identity |
2 |
RCSU-107 |
||||||
|
– CHOICE RLC size list |
Explicit list |
RCSU-108 |
||||||
|
– RLC size index |
According to clause 6.10.2.4.4.1 |
RCSU-109 |
||||||
|
– MAC logical channel priority |
2 |
RCSU-110 |
||||||
|
– Downlink RLC logical channel info |
RCSU-111 |
|||||||
|
– Number of downlink RLC logical channels |
1 |
RCSU-112 |
||||||
|
– Downlink transport channel type |
FACH |
RCSU-113 |
||||||
|
– DL DCH Transport channel identity |
Not Present |
RCSU-114 |
||||||
|
– DL DSCH Transport channel identity |
Not Present |
RCSU-115 |
||||||
|
– Logical channel identity |
2 |
RCSU-116 |
||||||
|
Signalling RB information to setup |
(AM DCCH for NAS_DT High priority) |
RCSU-117 |
||||||
|
– RB identity |
Not present |
RCSU-118 |
||||||
|
– CHOICE RLC info type |
RLC info |
RCSU-119 |
||||||
|
– CHOICE Uplink RLC mode |
AM RLC |
RCSU-120 |
||||||
|
– Transmission RLC discard |
RCSU-121 |
|||||||
|
– SDU discard mode |
No Discard |
RCSU-122 |
||||||
|
– MAX_DAT |
15 |
RCSU-123 |
||||||
|
– Transmission window size |
32 |
RCSU-124 |
||||||
|
– Timer_RST |
500 |
RCSU-125 |
||||||
|
– Max_RST |
1 |
RCSU-126 |
||||||
|
– Polling info |
RCSU-127 |
|||||||
|
– Timer_poll_prohibit |
200 |
RCSU-128 |
||||||
|
– Timer_poll |
200 |
RCSU-129 |
||||||
|
– Poll_PDU |
Not Present |
RCSU-130 |
||||||
|
– Poll_SDU |
1 |
RCSU-131 |
||||||
|
– Last transmission PDU poll |
TRUE |
RCSU-132 |
||||||
|
– Last retransmission PDU poll |
TRUE |
RCSU-133 |
||||||
|
– Poll_Windows |
99 |
RCSU-134 |
||||||
|
– Timer_poll_periodic |
Not Present |
RCSU-135 |
||||||
|
– CHOICE Downlink RLC mode |
AM RLC |
RCSU-136 |
||||||
|
– DL RLC PDU size |
According to clause 6.10.2.4.1.3 (standalone 13.6 kbps signalling radio bearer) |
Rel-6 |
RCSU-137 |
|||||
|
– In-sequence delivery |
TRUE |
RCSU-138 |
||||||
|
– Receiving window size |
32 |
RCSU-139 |
||||||
|
– Downlink RLC status info |
RCSU-140 |
|||||||
|
– Timer_status_prohibit |
200 |
RCSU-141 |
||||||
|
– Timer_EPC |
Not Present |
RCSU-142 |
||||||
|
– Missing PDU indicator |
TRUE |
RCSU-143 |
||||||
|
– Timer_STATUS_periodic |
Not Present |
RCSU-144 |
||||||
|
– RB mapping info |
RCSU-145 |
|||||||
|
– Information for each multiplexing option |
2 RBMuxOptions |
RCSU-146 |
||||||
|
– RLC logical channel mapping indicator |
Not Present |
RCSU-147 |
||||||
|
– Number of uplink RLC logical channels |
1 |
RCSU-148 |
||||||
|
– Uplink transport channel type |
DCH |
RCSU-149 |
||||||
|
– UL Transport channel identity |
5 |
RCSU-150 |
||||||
|
– Logical channel identity |
3 |
RCSU-151 |
||||||
|
– CHOICE RLC size list |
Configured |
RCSU-152 |
||||||
|
– MAC logical channel priority |
3 |
RCSU-153 |
||||||
|
– Downlink RLC logical channel info |
RCSU-154 |
|||||||
|
– Number of downlink RLC logical channels |
1 |
RCSU-155 |
||||||
|
– Downlink transport channel type |
DCH |
RCSU-156 |
||||||
|
– DL DCH Transport channel identity |
10 |
RCSU-157 |
||||||
|
– DL DSCH Transport channel identity |
Not Present |
RCSU-158 |
||||||
|
– Logical channel identity |
3 |
RCSU-159 |
||||||
|
– RLC logical channel mapping indicator |
Not Present |
RCSU-160 |
||||||
|
– Number of uplink RLC logical channels |
1 |
RCSU-161 |
||||||
|
– Uplink transport channel type |
RACH |
RCSU-162 |
||||||
|
– UL DCH Transport channel identity |
Not Present |
RCSU-163 |
||||||
|
– Logical channel identity |
3 |
RCSU-164 |
||||||
|
– CHOICE RLC size list |
Explicit list |
RCSU-165 |
||||||
|
– RLC size index |
According to clause 6.10.2.4.4.1 |
RCSU-166 |
||||||
|
– MAC logical channel priority |
3 |
RCSU-167 |
||||||
|
– Downlink RLC logical channel info |
RCSU-168 |
|||||||
|
– Number of downlink RLC logical channels |
1 |
RCSU-169 |
||||||
|
– Downlink transport channel type |
FACH |
RCSU-170 |
||||||
|
– DL DCH Transport channel identity |
Not Present |
RCSU-171 |
||||||
|
– DL DSCH Transport channel identity |
Not Present |
RCSU-172 |
||||||
|
– Logical channel identity |
3 |
RCSU-173 |
||||||
|
– Signalling RB information to setup |
(AM DCCH for NAS_DT Low priority) |
RCSU-174 |
||||||
|
– RB identity |
Not Present |
RCSU-175 |
||||||
|
– CHOICE RLC info type |
RLC info |
RCSU-176 |
||||||
|
– CHOICE Uplink RLC mode |
AM RLC |
RCSU-177 |
||||||
|
– Transmission RLC discard |
RCSU-178 |
|||||||
|
– SDU discard mode |
No Discard |
RCSU-179 |
||||||
|
– MAX_DAT |
15 |
RCSU-180 |
||||||
|
– Transmission window size |
32 |
RCSU-181 |
||||||
|
– Timer_RST |
500 |
RCSU-182 |
||||||
|
– Max_RST |
1 |
RCSU-183 |
||||||
|
– Polling info |
RCSU-184 |
|||||||
|
– Timer_poll_prohibit |
200 |
RCSU-185 |
||||||
|
– Timer_poll |
200 |
RCSU-186 |
||||||
|
– Poll_PDU |
Not Present |
RCSU-187 |
||||||
|
– Poll_SDU |
1 |
RCSU-188 |
||||||
|
– Last transmission PDU poll |
TRUE |
RCSU-189 |
||||||
|
– Last retransmission PDU poll |
TRUE |
RCSU-190 |
||||||
|
– Poll_Windows |
99 |
RCSU-191 |
||||||
|
– Timer_poll_periodic |
Not Present |
RCSU-192 |
||||||
|
– CHOICE Downlink RLC mode |
AM RLC |
RCSU-193 |
||||||
|
– DL RLC PDU size |
According to clause 6.10.2.4.1.3 (standalone 13.6 kbps signalling radio bearer) |
Rel-6 |
RCSU-194 |
|||||
|
– In-sequence delivery |
TRUE |
RCSU-195 |
||||||
|
– Receiving window size |
32 |
RCSU-196 |
||||||
|
– Downlink RLC status info |
RCSU-197 |
|||||||
|
– Timer_status_prohibit |
200 |
RCSU-198 |
||||||
|
– Timer_EPC |
Not Present |
RCSU-199 |
||||||
|
– Missing PDU indicator |
TRUE |
RCSU-200 |
||||||
|
– Timer_STATUS_periodic |
Not Present |
RCSU-201 |
||||||
|
– RB mapping info |
RCSU-202 |
|||||||
|
– Information for each multiplexing option |
2 RBMuxOptions |
RCSU-203 |
||||||
|
– RLC logical channel mapping indicator |
Not Present |
RCSU-204 |
||||||
|
– Number of uplink RLC logical channels |
1 |
RCSU-205 |
||||||
|
– Uplink transport channel type |
DCH |
RCSU-206 |
||||||
|
– UL Transport channel identity |
5 |
RCSU-207 |
||||||
|
– Logical channel identity |
4 |
RCSU-208 |
||||||
|
– CHOICE RLC size list |
Configured |
RCSU-209 |
||||||
|
– MAC logical channel priority |
4 |
RCSU-210 |
||||||
|
– Downlink RLC logical channel info |
RCSU-211 |
|||||||
|
– Number of downlink RLC logical channels |
1 |
RCSU-212 |
||||||
|
– Downlink transport channel type |
DCH |
RCSU-213 |
||||||
|
– DL DCH Transport channel identity |
10 |
RCSU-214 |
||||||
|
– DL DSCH Transport channel identity |
Not Present |
RCSU-215 |
||||||
|
– Logical channel identity |
4 |
RCSU-216 |
||||||
|
– RLC logical channel mapping indicator |
Not Present |
RCSU-217 |
||||||
|
– Number of uplink RLC logical channels |
1 |
RCSU-218 |
||||||
|
– Uplink transport channel type |
RACH |
RCSU-219 |
||||||
|
– UL Transport channel identity |
Not Present |
RCSU-220 |
||||||
|
– Logical channel identity |
4 |
RCSU-221 |
||||||
|
– CHOICE RLC size list |
Explicit list |
RCSU-222 |
||||||
|
– RLC size index |
According to clause 6.10.2.4.4.1 |
RCSU-223 |
||||||
|
– MAC logical channel priority |
4 |
RCSU-224 |
||||||
|
– Downlink RLC logical channel info |
RCSU-225 |
|||||||
|
– Number of downlink RLC logical channels |
1 |
RCSU-226 |
||||||
|
– Downlink transport channel type |
FACH |
RCSU-227 |
||||||
|
– DL DCH Transport channel identity |
Not Present |
RCSU-228 |
||||||
|
– DL DSCH Transport channel identity |
Not Present |
RCSU-229 |
||||||
|
– Logical channel identity |
4 |
RCSU-230 |
||||||
|
UL Transport channel information for all transport channels |
RCSU-231 |
|||||||
|
– PRACH TFCS |
Not Present |
RCSU-232 |
||||||
|
– CHOICE Mode |
FDD |
RCSU-233 |
||||||
|
– TFC subset |
Not Present |
RCSU-234 |
||||||
|
– UL DCH TFCS |
RCSU-235 |
|||||||
|
– CHOICE TFCI signalling |
Normal |
RCSU-236 |
||||||
|
– TFCI Field 1 information |
RCSU-237 |
|||||||
|
– CHOICE TFCS representation |
Complete |
RCSU-238 |
||||||
|
– TFCS complete reconfigure |
RCSU-239 |
|||||||
|
– CHOICE CTFC Size |
2bit CTFC |
RCSU-240 |
||||||
|
– CTFC information |
This IE is repeated for TFC numbers according to clause 6.10.2.4.1.3 (standalone 13.6 kbps signalling radio bearer) |
RCSU-241 |
||||||
|
– CTFC |
According to clause 6.10.2.4.1.3 (standalone 13.6 kbps signalling radio bearer) |
RCSU-242 |
||||||
|
– Power offset information |
RCSU-243 |
|||||||
|
– CHOICE Gain Factors |
Computed Gain Factors (The last TFC is set to Signalled Gain Factors) |
RCSU-244 |
||||||
|
– Gain factor ßc |
11 (below 64 kbps) 9 (equal or higher than 64 kbps) when HSDPA is not configured 9 (equal or higher than 64 kbps and below 384 kbps) when HSDPA is also configured 6 (equal or higher than 384 kbps) when HSDPA is also configured (Not Present if the above is set to Computed Gain Factors) |
RCSU-245 |
||||||
|
– Gain factor ßd |
15 (Not Present if the above is set to Computed Gain Factors) |
RCSU-246 |
||||||
|
– Reference TFC ID |
0 |
RCSU-247 |
||||||
|
– CHOICE mode |
FDD |
RCSU-248 |
||||||
|
– Power offset Pp-m |
Not Present |
RCSU-249 |
||||||
|
Added or Reconfigured TrCH information list |
TS 25.331 specifies that "Although this IE is not required when the IE "RRC state indicator" is set to "CELL_FACH", need is MP to align with ASN.1" |
RCSU-250 |
||||||
|
– Added or Reconfigured UL TrCH information |
RCSU-251 |
|||||||
|
– Uplink transport channel type |
DCH |
RCSU-252 |
||||||
|
– UL Transport channel identity |
5 |
RCSU-253 |
||||||
|
– TFS |
RCSU-254 |
|||||||
|
– CHOICE Transport channel type |
Dedicated transport channels |
RCSU-255 |
||||||
|
– Dynamic Transport format information |
RCSU-256 |
|||||||
|
– RLC Size |
bitMode sizeType2 {part1 2, part2 OMIT} This results in an RLC size of 144 bits |
RCSU-257 |
||||||
|
– Number of TBs and TTI List |
List with two entry |
RCSU-258 |
||||||
|
– Transmission Time Interval |
Not Present |
RCSU-259 |
||||||
|
– Number of Transport blocks |
0 |
RCSU-260 |
||||||
|
– Transmission Time Interval |
Not Present |
RCSU-261 |
||||||
|
– Number of Transport blocks |
1 |
RCSU-262 |
||||||
|
– CHOICE Logical channel List |
ALL |
RCSU-263 |
||||||
|
– Semi-static Transport Format information |
RCSU-264 |
|||||||
|
– Transmission time interval |
40 ms |
RCSU-265 |
||||||
|
– Type of channel coding |
Convolutional |
RCSU-266 |
||||||
|
– Coding Rate |
1/3 |
RCSU-267 |
||||||
|
– Rate matching attribute |
-170 |
RCSU-268 |
||||||
|
– CRC size |
16 |
RCSU-269 |
||||||
|
DL Transport channel information common for all transport channel |
RCSU-270 |
|||||||
|
– SCCPCH TFCS |
Not Present |
RCSU-271 |
||||||
|
– CHOICE mode |
FDD |
RCSU-272 |
||||||
|
– CHOICE DL parameters |
Same as UL |
RCSU-273 |
||||||
|
Added or Reconfigured TrCH information list |
TS 25.331 specifies that "Although this IE is not required when the IE "RRC state indicator" is set to "CELL_FACH", need is MP to align with ASN.1" |
RCSU-274 |
||||||
|
– Added or Reconfigured DL TrCH information |
RCSU-275 |
|||||||
|
– Downlink transport channel type |
DCH |
RCSU-276 |
||||||
|
– DL Transport channel identity |
10 |
RCSU-277 |
||||||
|
– CHOICE DL parameters |
Same as UL |
RCSU-278 |
||||||
|
– Uplink Transport channel type |
DCH |
RCSU-279 |
||||||
|
– UL TrCH identity |
5 |
RCSU-280 |
||||||
|
– DCH quality target |
Not Present |
RCSU-281 |
||||||
|
Frequency info |
Not present |
RCSU-282 |
||||||
|
Maximum allowed UL TX power |
Not present |
RCSU-283 |
||||||
|
CHOICE channel requirement |
Not Present |
RCSU-284 |
||||||
|
E-DCH Info |
Not Present |
Rel-6 |
RCSU-285 |
|||||
|
Downlink HS-PDSCH Information |
Not Present |
Rel-6 |
RCSU-286 |
|||||
|
Downlink information common for all radio links |
Not Present |
RCSU-287 |
||||||
|
Downlink information for each radio link list |
Not present |
RCSU-288 |
||||||
|
Condition |
Explanation |
Version |
|
UTRAN to E-UTRA |
This IE is needed for UTRAN to E-UTRA test cases |
Rel-8 |
Contents of RRC CONNECTION SETUP COMPLETE message: AM
|
Information Element |
Value/remark |
Version |
|
Message Type |
||
|
RRC transaction identifier |
The value of this IE is checked to see that it matches the value of the same IE transmitted in the downlink RRC CONNECTION SETUP message. |
|
|
START list |
This IE is checked to see if it is present. |
|
|
UE radio access capability |
Not checked |
|
|
– Access stratum release indicator |
Not checked |
|
|
– DL capability with simultaneous HS-DSCH configuration |
Not checked |
REL-5 |
|
– PDCP capability |
Not checked |
|
|
– RLC capability |
Not checked |
|
|
– Transport channel capability |
Not checked |
|
|
– RF capability FDD |
Not checked |
|
|
– RF capability TDD |
Not checked |
REL-4 |
|
– RF capability TDD 1.28 Mcps |
Not checked |
REL-4 |
|
– Physical channel capability |
Not checked |
|
|
– UE multi-mode/multi-RAT capability |
Not checked |
|
|
– Security capability |
||
|
– Ciphering algorithm capability |
||
|
>UEA0 |
TRUE |
|
|
>UEA1 |
TRUE |
|
|
>UEA2 |
To be checked against PICS |
REL-7 |
|
– Integrity protection algorithm capability |
||
|
>UIA1 |
TRUE |
|
|
>UIA2 |
To be checked against PICS |
REL-7 |
|
– UE positioning capability |
Not checked |
|
|
– Measurement capability |
Not checked |
|
|
– Measurement capability TDD |
Not checked |
REL-8 |
|
– Device type |
Not checked |
REL-6 |
|
– Support for System Information Block type 11bis |
Not checked |
REL-6 |
|
– Support for F-DPCH |
To be checked against requirement if specified |
REL-6 |
|
– MAC-ehs support |
To be checked against requirement if specified |
REL-7 |
|
– UE specific capability Information LCR TDD |
Not checked |
REL-7 |
|
– Support for E-DPCCH Power Boosting |
Not checked |
REL-7 |
|
– Support of common E-DCH |
To be checked against requirement if specified |
REL-8 |
|
– Support of MAC-i/is |
To be checked against requirement if specified |
REL-8 |
|
– Support of SPS operation |
Not checked |
REL-8 |
|
– Support of Control Channel DRX operation |
Not checked |
REL-8 |
|
– Support of CSG |
To be checked against requirement if specified |
REL-8 |
|
– Support for Two DRX schemes in URA_PCH and CELL_PCH |
To be checked against requirement if specified |
REL-7 |
|
– Support for E-DPDCH power interpolation formula |
Not checked |
REL-7 |
|
– Support for absolute priority based cell re-selection in UTRAN |
To be checked against requirement if specified |
REL-8 |
|
– Support of MU-MIMO |
Not checked |
REL-10 |
|
– Radio Access Capability Band Combination List |
To be checked against requirement if specified |
REL-9 |
|
– Support of TX Diversity on DL Control Channels by MIMO Capable UE when MIMO operation is active |
To be checked against requirement if specified |
REL-7 |
|
– Support of enhanced TS0 |
To be checked against requirement if specified |
REL-9 |
|
– Support for cell-specific Tx diversity configuration for dual-cell operation |
To be checked against requirement if specified |
REL-8 |
|
– CSG proximity indication capability |
To be checked against requirement if specified |
REL-9 |
|
– Neighbour Cell SI acquisition capability |
To be checked against requirement if specified |
REL-9 |
|
– Extended measurements Support |
To be checked against requirement if specified |
REL-9 |
|
– Support for dual cell with MIMO operation in different bands |
To be checked against requirement if specified |
REL-10 |
|
– UE based network performance measurements parameters |
To be checked against requirement if specified |
REL-10 |
|
– Support of UTRAN ANR |
To be checked against requirement if specified |
REL-10 |
|
UE radio access capability extension |
Not checked |
|
|
UE system specific capability |
Not checked |
|
|
Deferred measurement control reading |
Not Present for Rel-7 or later, otherwise Not checked |
|
|
Logged Meas Available |
Not checked |
REL-10 |
|
ANR Logging Results Available |
Not checked |
REL-10 |
|
Connection Establishment Failure Info Available |
Not checked |
REL-11 |
Contents of RRC STATUS message: AM
|
Information Element |
Value/remark |
|
Message Type |
|
|
Integrity check info |
|
|
– Message authentication code |
This IE is checked to see if it is present. The value is compared against the XMAC-I value computed by SS. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
|
– RRC Message sequence number |
This IE is checked to see if it is present. The value is used by SS to compute the XMAC-I value. |
|
Identification of received message |
Not Checked |
|
Protocol error information |
|
|
– Protocol error cause |
Refer to test requirement. |
Contents of SECURITY MODE COMMAND message: AM
|
Information Element |
Condition |
Value/remark |
Version |
|---|---|---|---|
|
Message Type |
A1, A2 |
||
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
||
|
Integrity check info |
|||
|
– Message authentication code |
Set to MAC-I value computed by the SS. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
||
|
– RRC Message Sequence Number |
Set to an arbitrarily selected integer between 0 and 15 |
||
|
Security capability |
|||
|
– Ciphering algorithm capability |
|||
|
– UEA0 |
If the UE has indicated support for ciphering algorithm UEA0 in the IE "security capability" in the RRC CONNECTION SETUP COMPLETE message, this IE is set to TRUE. |
||
|
– UEA1 |
If the UE has indicated support for ciphering algorithm UEA1 in the IE "security capability" in the RRC CONNECTION SETUP COMPLETE message, this IE is set to TRUE. |
||
|
– UEA2 |
If the UE has indicated support for ciphering algorithm UEA2 in the IE "security capability" in the RRC CONNECTION SETUP COMPLETE message, this IE is set to TRUE. |
Rel-7 |
|
|
– Spare |
Spare 3-15 = FALSE |
||
|
– Integrity protection algorithm capability |
0000000000000010B (UIA1) |
||
|
– UIA1 |
TRUE |
||
|
– UIA2 |
If the UE has indicated support for integrity algorithm UIA2 in the IE "security capability" in the RRC CONNECTION SETUP COMPLETE message, this IE is set to TRUE. |
Rel-7 |
|
|
– Spare |
Spare 0 and Spare 3-15 = FALSE |
||
|
Ciphering mode info |
This presence of this IE is dependent on IXIT statements in TS 34.123-2. If ciphering is indicated to be active, this IE present with the values of the sub IEs as stated below. Else, this IE is omitted. |
||
|
– Ciphering mode command |
Start/restart |
||
|
– Ciphering algorithm |
UEA0 or UEA1 or UEA2. The indicated algorithm must be one of the algorithms supported by the UE as indicated in the IE "security capability" in the RRC CONNECTION SETUP COMPLETE message. |
||
|
– Ciphering activation time for DPCH |
Not Present |
||
|
– Radio bearer downlink ciphering activation time info |
|||
|
– Radio bearer activation time |
|||
|
– RB identity |
1 |
||
|
– RLC sequence number |
Current RLC SN |
||
|
– RB identity |
2 |
||
|
– RLC sequence number |
Current RLC SN+2 |
||
|
– RB identity |
3 |
||
|
– RLC sequence number |
Current RLC SN |
||
|
– RB identity |
4 |
||
|
– RLC sequence number |
Current RLC SN |
||
|
Integrity protection mode info |
|||
|
– Integrity protection mode command |
Start |
||
|
– Downlink integrity protection activation info |
Not Present |
||
|
– Integrity protection algorithm |
UIA1 or UIA2. The indicated algorithm must be one of the algorithms supported by the UE as indicated in the IE "security capability" in the RRC CONNECTION SETUP COMPLETE message |
||
|
– Integrity protection initialisation number |
SS selects an arbitrary 32 bits number for FRESH |
||
|
CN domain identity |
CS or PS |
||
|
UE system specific security capability |
A1 |
Not Checked |
|
|
UE system specific security capability |
A2 |
||
|
– Inter-RAT UE security capability |
|||
|
– CHOICE system |
GSM |
||
|
– GSM security capability |
The indicated algorithms must be the same as the algorithms supported by the UE as indicated in the IE " UE system specific capability " in the RRC CONNECTION SETUP COMPLETE message. |
|
Condition |
Explanation |
|
A1 |
UE not supporting GSM |
|
A2 |
UE supporting GSM |
Contents of SECURITY MODE COMPLETE message: AM
|
Information Element |
Value/remark |
|---|---|
|
Message Type |
|
|
RRC transaction identifier |
The value of this IE is checked to see that it matches the value of the same IE transmitted in the downlink SECURITY MODE COMMAND message. |
|
Integrity check info |
|
|
– Message authentication code |
This IE is checked to see if it is present. The value is compared against the XMAC-I value computed by SS. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
|
– RRC Message sequence number |
This IE is checked to see if it is present. The value is used by SS to compute the XMAC-I value. |
|
Uplink integrity protection activation info |
Not checked. |
|
Radio bearer uplink ciphering activation time info |
If ciphering is not activated in SECURITY MODE COMMAND message, this IE must be absent. Else, SS checks this IE for the presence of activation times for all ciphered uplink RLC-UM and RLC-AM RBs. |
Contents of SECURITY MODE FAILURE message: AM
|
Information Element |
Value/remark |
|
Message Type |
|
|
RRC transaction identifier |
Checked to see if the value is the identical to the same IE in the downlink SECURITY MODE COMMAND message. |
|
Integrity check info |
|
|
– Message authentication code |
This IE is checked to see if it is present. The value is compared against the XMAC-I value computed by SS. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
|
– RRC Message sequence number |
This IE is checked to see if it is present. The value is used by SS to compute the XMAC-I value. |
|
Failure cause |
Refer to test requirement. |
Contents of TRANSPORT CHANNEL RECONFIGURATION message: AM or UM
|
Information Element |
Condition |
Value/remark |
Version |
Index |
|---|---|---|---|---|
|
Message Type |
A1, A2, A3, A4, A5, A6 |
TCR-001 |
||
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
TCR-002 |
||
|
Integrity check info |
TCR-003 |
|||
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
TCR-004 |
||
|
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
TCR-005 |
||
|
Integrity protection mode info |
Not Present |
TCR-006 |
||
|
Ciphering mode info |
Not Present |
TCR-007 |
||
|
Activation time |
A1, A2, A3 |
(256+CFN-(CFN MOD 8 + 8))MOD 256 |
TCR-008 |
|
|
Activation time |
A4, A5, A6 |
Not Present |
TCR-009 |
|
|
Delay restriction flag |
A1, A2, A3, A4, A5, A6 |
Not Present |
Rel-6 |
TCR-010 |
|
New U-RNTI |
|
Not Present |
TCR-011 |
|
|
New C-RNTI |
A1, A2, A3, A4 |
Not Present |
TCR-012 |
|
|
New C-RNTI |
A5, A6 |
‘1010 1010 1010 1010’ |
TCR-013 |
|
|
New DSCH-RNTI |
A1, A2, A3, A4, A5, A6 |
Not Present |
R99 and Rel-4 only |
TCR-014 |
|
New H-RNTI |
A1, A2, A3, A4, A5, A6 |
Not Present |
Rel-5 |
TCR-015 |
|
New Primary E-RNTI |
Not Present |
Rel-6 |
TCR-016 |
|
|
New Secondary E-RNTI |
Not Present |
Rel-6 |
TCR-017 |
|
|
RRC State indicator |
A1, A2, A3, A4 |
CELL_DCH |
TCR-018 |
|
|
RRC State indicator |
A5, A6 |
CELL_FACH |
TCR-019 |
|
|
UE Mobility State Indicator |
Not Present |
Rel-7 |
TCR-020 |
|
|
UTRAN DRX cycle length coefficient |
A1, A2, A3, A4,A5,A6 |
Not Present |
TCR-021 |
|
|
CN information info |
Not Present |
TCR-022 |
||
|
URA identity |
Not Present |
TCR-023 |
||
|
RNC support for change of UE capability |
Not Present |
Rel-7 |
TCR-024 |
|
|
Reconfiguration in response to requested change of UE capability |
Not Present |
Rel-7 |
TCR-025 |
|
|
Downlink counter synchronization info |
Not Present |
TCR-026 |
||
|
UL Transport channel information for all transport channels |
A1, A2, A5, A6 |
Not Present |
TCR-027 |
|
|
UL Transport channel information for all transport channels |
A3, A4 |
TCR-028 |
||
|
– PRACH TFCS |
Not Present |
TCR-029 |
||
|
– CHOICE mode |
FDD |
TCR-030 |
||
|
– TFC subset |
Not Present |
TCR-031 |
||
|
– UL DCH TFCS |
|
TCR-032 |
||
|
– CHOICE TFCI signalling |
Normal |
TCR-033 |
||
|
– TFCI Field 1 information |
TCR-034 |
|||
|
– CHOICE TFCS representation |
Complete reconfiguration |
TCR-035 |
||
|
– TFCS complete reconfigure information |
TCR-036 |
|||
|
– CHOICE CTFC Size |
Number of bits used must be enough to cover all combinations of CTFC from clause 6.10.2.4 Parameter Set. |
TCR-037 |
||
|
– CTFC information |
This IE is repeated for TFC numbers and reference to clause 6.10.2.4 Parameter Set |
TCR-038 |
||
|
– CTFC |
Reference to clause 6.10.2.4 Parameter Set |
TCR-039 |
||
|
– Power offset information |
|
TCR-040 |
||
|
– CHOICE Gain Factors |
Computed Gain Factors (The last TFC is set to Signalled Gain Factors) |
TCR-041 |
||
|
– Gain factor βc |
11 (equal or below 64 kbps) when HSDPA is not configured 9 (equal or higher than 64 kbps and below 384 kbps) when HSDPA is also configured 6 (equal or higher than 384 kbps) when HSDPA is also configured 9 (higher than 64 kbps) (Not Present if the CHOICE Gain Factors is set to ComputedGain Factors) |
TCR-042 |
||
|
– Gain factor βd |
15 (Not Present if the CHOICE Gain Factors is set to ComputedGain Factors) |
TCR-043 |
||
|
– Reference TFC ID |
0 |
TCR-044 |
||
|
– CHOICE mode |
FDD |
TCR-045 |
||
|
– Power offset P p-m |
Not Present |
TCR-046 |
||
|
Added or Reconfigured UL TrCH information |
A1, A2, A5, A6 |
Not Present |
TCR-047 |
|
|
Added or Reconfigured UL TrCH information |
A4 |
2 TrCHs(DCH for DCCH and DCH for DTCH) |
TCR-048 |
|
|
– Uplink transport channel type |
|
DCH |
TCR-049 |
|
|
– UL Transport channel identity |
|
5 |
TCR-050 |
|
|
– TFS |
|
|
TCR-051 |
|
|
– CHOICE Transport channel type |
|
Dedicated transport channels |
TCR-052 |
|
|
– Dynamic Transport format information |
|
|
TCR-053 |
|
|
– RLC Size |
Reference to clause 6.10 Parameter Set |
TCR-054 |
||
|
– Number of TBs and TTI List |
(This IE is repeated for TFI number.) |
TCR-055 |
||
|
– Transmission Time Interval |
Not Present |
TCR-056 |
||
|
– Number of Transport blocks |
Reference to clause 6.10 Parameter Set |
TCR-057 |
||
|
– CHOICE Logical channel list |
All |
TCR-058 |
||
|
– Semi-static Transport Format information |
|
TCR-059 |
||
|
– Transmission time interval |
Reference to clause 6.10 Parameter Set |
TCR-060 |
||
|
– Type of channel coding |
Reference to clause 6.10 Parameter Set |
TCR-061 |
||
|
– Coding Rate |
Reference to clause 6.10 Parameter Set |
TCR-062 |
||
|
– Rate matching attribute |
Reference to clause 6.10 Parameter Set |
TCR-063 |
||
|
– CRC size |
Reference to clause 6.10 Parameter Set |
TCR-064 |
||
|
– Uplink transport channel type |
DCH |
TCR-065 |
||
|
– UL Transport channel identity |
1 |
TCR-066 |
||
|
– TFS |
TCR-067 |
|||
|
– CHOICE Transport channel type |
Dedicated transport channels |
TCR-068 |
||
|
– Dynamic Transport format information |
TCR-069 |
|||
|
– RLC Size |
Reference to clause 6.10 Parameter Set |
TCR-070 |
||
|
– Number of TBs and TTI List |
(This IE is repeated for TFI number.) |
TCR-071 |
||
|
– Transmission Time Interval |
Not Present |
TCR-072 |
||
|
– Number of Transport blocks |
Reference to clause 6.10 Parameter Set |
TCR-073 |
||
|
– CHOICE Logical channel list |
All |
TCR-074 |
||
|
– Semi-static Transport Format information |
|
TCR-075 |
||
|
– Transmission time interval |
Reference to clause 6.10 Parameter Set |
TCR-076 |
||
|
– Type of channel coding |
Reference to clause 6.10 Parameter Set |
TCR-077 |
||
|
– Coding Rate |
Reference to clause 6.10 Parameter Set |
TCR-078 |
||
|
– Rate matching attribute |
Reference to clause 6.10 Parameter Set |
TCR-079 |
||
|
– CRC size |
Reference to clause 6.10 Parameter Set |
TCR-080 |
||
|
Added or Reconfigured UL TrCH information |
A3 |
(DCH for DTCH) |
TCR-081 |
|
|
– Uplink transport channel type |
DCH |
TCR-082 |
||
|
– UL Transport channel identity |
1 |
TCR-083 |
||
|
– TFS |
|
TCR-084 |
||
|
– CHOICE Transport channel type |
Dedicated transport channels |
TCR-085 |
||
|
– Dynamic Transport format information |
|
TCR-086 |
||
|
– RLC Size |
Reference to clause 6.10 Parameter Set |
TCR-087 |
||
|
– Number of TBs and TTI List |
(This IE is repeated for TFI number.) |
TCR-088 |
||
|
– Transmission Time Interval |
Not Present |
TCR-089 |
||
|
– Number of Transport blocks |
Reference to clause 6.10 Parameter Set |
TCR-090 |
||
|
– CHOICE Logical channel list |
All |
TCR-091 |
||
|
– Semi-static Transport Format information |
|
TCR-092 |
||
|
– Transmission time interval |
Reference to clause 6.10 Parameter Set |
TCR-093 |
||
|
– Type of channel coding |
Reference to clause 6.10 Parameter Set |
TCR-094 |
||
|
– Coding Rate |
Reference to clause 6.10 Parameter Set |
TCR-095 |
||
|
– Rate matching attribute |
Reference to clause 6.10 Parameter Set |
TCR-096 |
||
|
– CRC size |
Reference to clause 6.10 Parameter Set |
TCR-097 |
||
|
CHOICE mode |
A1,A2,A3,A4,A5,A6 |
Not Present |
TCR-098 |
|
|
DL Transport channel information common for all transport channel |
A1, A2, A5,A6 |
Not Present |
TCR-099 |
|
|
DL Transport channel information common for all transport channel |
A3,A4 |
TCR-100 |
||
|
– SCCPCH TFCS |
Not Present |
TCR-101 |
||
|
– CHOICE mode |
FDD |
TCR-102 |
||
|
– CHOICE DL parameters |
Explicit |
TCR-103 |
||
|
– DL DCH TFCS |
|
TCR-104 |
||
|
– CHOICE TFCI Signalling |
Normal |
TCR-105 |
||
|
– TFCI Field 1 Information |
TCR-106 |
|||
|
– CHOICE TFCS representation |
Complete reconfiguration |
TCR-107 |
||
|
– TFCS complete reconfigure |
TCR-108 |
|||
|
– CHOICE CTFC Size |
Number of bits used must be enough to cover all combinations of CTFC from clause 6.10.2.4 Parameter Set. |
TCR-109 |
||
|
– CTFC information |
This IE is repeated for TFC numbers and reference to clause 6.10.2.4 |
TCR-110 |
||
|
– CTFC |
Reference to clause 6.10.2.4 Parameter Set |
TCR-111 |
||
|
– Power offset information |
Not Present |
TCR-112 |
||
|
Added or Reconfigured DL TrCH information |
A1, A2, A5, A6 |
Not Present |
TCR-113 |
|
|
Added or Reconfigured DL TrCH information |
A4 |
2 TrCHs(DCH for DCCH and DCH for DTCH) |
TCR-114 |
|
|
– Downlink transport channel type |
DCH |
TCR-115 |
||
|
– DL Transport channel identity |
10 |
TCR-116 |
||
|
– CHOICE DL parameters |
Same as UL |
TCR-117 |
||
|
– Uplink transport channel type |
DCH |
TCR-118 |
||
|
– UL TrCH identity |
5 |
TCR-119 |
||
|
– DCH quality target |
|
TCR-120 |
||
|
– BLER Quality value |
Not Present |
TCR-121 |
||
|
– Downlink transport channel type |
DCH |
TCR-122 |
||
|
– DL Transport channel identity |
6 |
TCR-123 |
||
|
– CHOICE DL parameters |
Explicit Except for RAB with the symmetric DL and UL rate: Same as UL |
TCR-124 |
||
|
– TFS |
|
TCR-125 |
||
|
– CHOICE Transport channel type |
Dedicated transport channel |
TCR-126 |
||
|
– Dynamic transport format information |
|
TCR-127 |
||
|
– RLC Size |
Reference to clause 6.10 Parameter Set |
TCR-128 |
||
|
– Number of TBs and TTI List |
(This IE is repeated for TFI number.) |
TCR-129 |
||
|
– Dynamic transport format information |
|
TCR-130 |
||
|
– Transmission Time Interval |
Not Present |
TCR-131 |
||
|
– Number of Transport blocks |
Reference to clause 6.10 Parameter Set |
TCR-132 |
||
|
– Semi-static Transport Format information |
|
TCR-133 |
||
|
– Transmission time interval |
Reference to clause 6.10 Parameter Set |
TCR-134 |
||
|
– Type of channel coding |
Reference to clause 6.10 Parameter Set |
TCR-135 |
||
|
– Coding Rate |
Reference to clause 6.10 Parameter Set |
TCR-136 |
||
|
– Rate matching attribute |
Reference to clause 6.10 Parameter Set |
TCR-137 |
||
|
– CRC size |
Reference to clause 6.10 Parameter Set |
TCR-138 |
||
|
– DCH quality target |
|
TCR-139 |
||
|
– BLER Quality value |
-20 (-2.0) |
TCR-140 |
||
|
Added or Reconfigured DL TrCH information |
A3 |
TCR-141 |
||
|
– Downlink transport channel type |
DCH |
TCR-142 |
||
|
– DL Transport channel identity |
6 |
TCR-143 |
||
|
– CHOICE DL parameters |
Explicit Except for RAB with the symmetric DL and UL rate: Same as UL |
TCR-144 |
||
|
– TFS |
|
TCR-145 |
||
|
– CHOICE Transport channel type |
Dedicated transport channel |
TCR-146 |
||
|
– Dynamic transport format information |
|
TCR-147 |
||
|
– RLC Size |
Reference to clause 6.10 Parameter Set |
TCR-148 |
||
|
– Number of TBs and TTI List |
(This IE is repeated for TFI number.) |
TCR-149 |
||
|
– Dynamic transport format information |
|
TCR-150 |
||
|
– Transmission Time Interval |
Not Present |
TCR-151 |
||
|
– Number of Transport blocks |
Reference to clause 6.10 Parameter Set |
TCR-152 |
||
|
– Semi-static Transport Format information |
|
TCR-153 |
||
|
– Transmission time interval |
Reference to clause 6.10 Parameter Set |
TCR-154 |
||
|
– Type of channel coding |
Reference to clause 6.10 Parameter Set |
TCR-155 |
||
|
– Coding Rate |
Reference to clause 6.10 Parameter Set |
TCR-156 |
||
|
– Rate matching attribute |
Reference to clause 6.10 Parameter Set |
TCR-157 |
||
|
– CRC size |
Reference to clause 6.10 Parameter Set |
TCR-158 |
||
|
– DCH quality target |
|
TCR-159 |
||
|
– BLER Quality value |
-20 (-2.0) |
TCR-160 |
||
|
Frequency info |
A1,A2,A3,A4,A5 |
|
TCR-161 |
|
|
– UARFCN uplink (Nu) |
|
Not present Absence of this IE is equivalent to applying the default duplex distance defined for the operating frequency according to 3GPP TS 25.101 [11] |
TCR-162 |
|
|
– UARFCN downlink (Nd) |
|
Reference to clause 5.1 Test frequencies |
TCR-163 |
|
|
Frequency info |
A6 |
Not Present |
TCR-164 |
|
|
DTX-DRX timing information |
Not Present |
Rel-7 |
TCR-165 |
|
|
DTX-DRX Information |
Not Present |
Rel-7 |
TCR-166 |
|
|
HS-SCCH less Information |
Not Present |
Rel-7 |
TCR-167 |
|
|
MIMO parameters |
Not Present |
Rel-7 |
TCR-168 |
|
|
Maximum allowed UL TX power |
A1, A2, A3, A4, A5, A6 |
33dBm |
|
TCR-169 |
|
CHOICE channel requirement |
A5, A6 |
Not Present |
|
TCR-170 |
|
CHOICE channel requirement |
A1, A2, A3, A4 |
Uplink DPCH info |
|
TCR-171 |
|
-Uplink DPCH power control info |
|
|
|
TCR-172 |
|
– DPCCH power offset |
|
-40 (-80dB) |
|
TCR-173 |
|
– PC Preamble |
|
1 frame |
|
TCR-174 |
|
– SRB delay |
|
7 frames |
|
TCR-175 |
|
– Power Control Algorithm |
|
Algorithm1 |
|
TCR-176 |
|
– TPC step size |
|
0 (1dB) |
|
TCR-177 |
|
– ACK |
|
Not Present |
Rel-5 |
TCR-178 |
|
– NACK |
|
Not Present |
Rel-5 |
TCR-179 |
|
– Ack-Nack repetition factor |
|
Not Present |
Rel-5 |
TCR-180 |
|
– Scrambling code type |
|
Long |
|
TCR-181 |
|
– Scrambling code number |
|
0 (0 to 16777215) |
|
TCR-182 |
|
– Number of DPDCH |
|
Not Present(1) |
|
TCR-183 |
|
– spreading factor |
|
Reference to clause 6.10 Parameter Set |
|
TCR-184 |
|
– TFCI existence |
|
Reference to clause 6.10 Parameter Set |
|
TCR-185 |
|
– Number of FBI bit |
|
Reference to clause 6.10 Parameter Set |
|
TCR-186 |
|
– Number of TPC bits |
Not Present |
Rel-7 |
TCR-187 |
|
|
– Puncturing Limit |
|
Reference to clause 6.10 Parameter Set |
|
TCR-188 |
|
E-DCH Info |
Not Present |
Rel-6 |
TCR-189 |
|
|
CHOICE Mode |
A1, A2, A3, A4, A5, A6 |
FDD |
R99 and Rel-4 only |
TCR-190 |
|
– Downlink PDSCH information |
|
Not Present |
R99 and Rel-4 only |
TCR-191 |
|
Downlink HS-PDSCH Information |
A1, A2, A3, A4, A5, A6 |
Not Present |
Rel-5 |
TCR-192 |
|
Downlink information common for all radio links |
A5, A6 |
Not Present |
|
TCR-193 |
|
Downlink information common for all radio links |
A1, A2, A3 |
|
|
TCR-194 |
|
– Downlink DPCH info common for all RL |
|
|
|
TCR-195 |
|
– Timing indicator |
|
Maintain |
|
TCR-196 |
|
– CFN-targetSFN frame offset |
|
Not Present |
|
TCR-197 |
|
– Downlink DPCH power control information |
|
|
|
TCR-198 |
|
– DPC mode |
|
0 (single) |
|
TCR-199 |
|
– CHOICE mode |
|
FDD |
|
TCR-200 |
|
– Power offset PPilot-DPDCH |
|
0 |
|
TCR-201 |
|
– DL rate matching restriction information |
|
Not Present |
|
TCR-202 |
|
– Spreading factor |
|
Reference to clause 6.10 Parameter Set |
|
TCR-203 |
|
– Fixed or Flexible Position |
|
Reference to clause 6.10 Parameter Set |
|
TCR-204 |
|
– TFCI existence |
|
Reference to clause 6.10 Parameter Set |
|
TCR-205 |
|
– CHOICE SF |
|
Reference to clause 6.10 Parameter Set |
|
TCR-206 |
|
– DPCH compressed mode info |
|
Not Present |
|
TCR-207 |
|
– TX Diversity mode |
|
None |
|
TCR-208 |
|
– SSDT information |
|
Not Present |
R99 and Rel-4 only |
TCR-209 |
|
– Default DPCH Offset Value |
|
Not Present |
|
TCR-210 |
|
– MAC-hs reset indicator |
|
Not Present |
Rel-5 |
TCR-211 |
|
Downlink information common for all radio links |
A4 |
|
|
TCR-212 |
|
– Downlink DPCH info common for all RL |
|
|
|
TCR-213 |
|
– Timing indicator |
|
Initialize |
|
TCR-214 |
|
– CFN-targetSFN frame offset |
|
Not Present |
|
TCR-215 |
|
– Downlink DPCH power control information |
|
|
|
TCR-216 |
|
– DPC mode |
|
0 (single) |
|
TCR-217 |
|
– CHOICE mode |
|
FDD |
|
TCR-218 |
|
– Power offset PPilot-DPDCH |
|
0 |
|
TCR-219 |
|
– DL rate matching restriction information |
|
Not Present |
|
TCR-220 |
|
– Spreading factor |
|
Reference to clause 6.10 Parameter Set |
|
TCR-221 |
|
– Fixed or Flexible Position |
|
Reference to clause 6.10 Parameter Set |
|
TCR-222 |
|
– TFCI existence |
|
Reference to clause 6.10 Parameter Set |
|
TCR-223 |
|
– CHOICE SF |
|
Reference to clause 6.10 Parameter Set |
|
TCR-224 |
|
– DPCH compressed mode info |
|
Not Present |
|
TCR-225 |
|
– TX Diversity mode |
|
None |
|
TCR-226 |
|
– SSDT information |
|
Not Present |
R99 and Rel-4 only |
TCR-227 |
|
– Default DPCH Offset Value |
|
Arbitrary set to value 0..306688 by step of 512 |
|
TCR-228 |
|
– MAC-hs reset indicator |
|
Not Present |
Rel-5 |
TCR-229 |
|
Downlink information for each radio link list |
A1, A2, A3 |
|
|
TCR-230 |
|
– Downlink information for each radio links |
|
|
|
TCR-231 |
|
– CHOICE mode |
|
FDD |
|
TCR-232 |
|
– Primary CPICH info |
|
|
|
TCR-233 |
|
– Primary scrambling code |
|
Ref. to the Default setting in clause 6.1 (FDD) |
|
TCR-234 |
|
– PDSCH with SHO DCH info |
|
Not Present |
R99 and Rel-4 only |
TCR-235 |
|
– PDSCH code mapping |
|
Not Present |
R99 and Rel-4 only |
TCR-236 |
|
– Serving HS-DSCH radio link indicator |
|
FALSE |
Rel-5 |
TCR-237 |
|
– Serving E-DCH radio link indicator |
FALSE |
Rel-6 |
TCR-238 |
|
|
– Downlink DPCH info for each RL |
|
|
|
TCR-239 |
|
– Primary CPICH usage for channel estimation |
|
Primary CPICH may be used |
|
TCR-240 |
|
– DPCH frame offset |
|
Set to value Default DPCH Offset Value ( as currently stored in SS) mod 38 400 |
|
TCR-241 |
|
– Power offset PPilot-DPDCH |
|
0 |
|
TCR-242 |
|
– Secondary CPICH info |
|
Not Present |
|
TCR-243 |
|
– DL channelisation code |
|
|
|
TCR-244 |
|
– Secondary scrambling code |
|
4 |
|
TCR-245 |
|
– Spreading factor |
|
Reference to clause 6.10 Parameter Set |
|
TCR-246 |
|
– Code number |
|
0 |
|
TCR-247 |
|
– Scrambling code change |
|
Set to value Default1: No code change (if the UE has a compressed mode pattern sequence configured in variable TGPS_IDENTITY or included in the message including IE "Downlink DPCH info for each RL", which is using compressed mode method "SF/2") Set to value Default2: OMIT (otherwise) |
TCR-248 |
|
|
– TPC combination index |
|
0 |
|
TCR-249 |
|
– SSDT Cell Identity |
|
Not Present |
R99 and Rel-4 only |
TCR-250 |
|
– Closed loop timing adjustment mode |
|
Not Present |
|
TCR-251 |
|
– E-AGCH Info |
Not Present |
Rel-6 |
TCR-252 |
|
|
– E-HICH Information |
Not Present |
Rel-6 |
TCR-253 |
|
|
– E-RGCH Information |
Not Present |
Rel-6 |
TCR-254 |
|
|
– SCCPCH information for FACH |
|
Not Present |
R99 and Rel-4 only |
TCR-255 |
|
Downlink information for each radio link list |
A4 |
TCR-256 |
||
|
– Downlink information for each radio link |
TCR-257 |
|||
|
– CHOICE mode |
FDD |
TCR-258 |
||
|
– Primary CPICH info |
TCR-259 |
|||
|
– Primary scrambling code |
Ref. to the Default setting in clause 6.1 (FDD) |
TCR-260 |
||
|
– PDSCH with SHO DCH info |
Not Present |
R99 and Rel-4 only |
TCR-261 |
|
|
– PDSCH code mapping |
Not Present |
R99 and Rel-4 only |
TCR-262 |
|
|
– Serving HS-DSCH radio link indicator |
FALSE |
Rel-5 |
TCR-263 |
|
|
– Serving E-DCH radio link indicator |
FALSE |
Rel-6 |
TCR-264 |
|
|
– Downlink DPCH info for each RL |
TCR-265 |
|||
|
– Primary CPICH usage for channel estimation |
Primary CPICH may be used |
TCR-266 |
||
|
– DPCH frame offset |
Set to value: Default DPCH Offset Value mod 38 400 |
TCR-267 |
||
|
– Power offset PPilot-DPDCH |
0 |
TCR-268 |
||
|
– Secondary CPICH info |
Not Present |
TCR-269 |
||
|
– DL channelisation code |
TCR-270 |
|||
|
– Secondary scrambling code |
4 |
TCR-271 |
||
|
– Spreading factor |
Reference to clause 6.10 Parameter Set |
TCR-272 |
||
|
– Code number |
0 |
TCR-273 |
||
|
– Scrambling code change |
Set to value Default1: No code change (if the UE has a compressed mode pattern sequence configured in variable TGPS_IDENTITY or included in the message including IE "Downlink DPCH info for each RL", which is using compressed mode method "SF/2") Set to value Default2: OMIT (otherwise) |
TCR-274 |
||
|
– TPC combination index |
0 |
TCR-275 |
||
|
– SSDT Cell Identity |
Not Present |
R99 and Rel-4 only |
TCR-276 |
|
|
– Closed loop timing adjustment mode |
Not Present |
TCR-277 |
||
|
– E-AGCH Info |
Not Present |
Rel-6 |
TCR-278 |
|
|
– E-HICH Information |
Not Present |
Rel-6 |
TCR-279 |
|
|
– E-RGCH Information |
Not Present |
Rel-6 |
TCR-280 |
|
|
– SCCPCH information for FACH |
Not Present |
R99 and Rel-4 only |
TCR-281 |
|
|
– Downlink information for each radio link |
A5 |
TCR-282 |
||
|
– Choice mode |
FDD |
TCR-283 |
||
|
– Primary CPICH info |
TCR-284 |
|||
|
– Primary scrambling code |
Ref. to the Default setting in clause 6.1 (FDD) |
TCR-285 |
||
|
– PDSCH with SHO DCH info |
Not Present |
R99 and Rel-4 only |
TCR-286 |
|
|
– PDSCH code mapping |
Not Present |
R99 and Rel-4 only |
TCR-287 |
|
|
– Serving HS-DSCH radio link indicator |
FALSE |
Rel-5 |
TCR-288 |
|
|
– Serving E-DCH radio link indicator |
FALSE |
Rel-6 |
TCR-289 |
|
|
– Downlink DPCH info for each RL |
Not present |
TCR-290 |
||
|
– E-AGCH Info |
Not Present |
Rel-6 |
TCR-291 |
|
|
– E-HICH Information |
Not Present |
Rel-6 |
TCR-292 |
|
|
– E-RGCH Information |
Not Present |
Rel-6 |
TCR-293 |
|
|
– SCCPCH information for FACH |
Not Present |
R99 and Rel-4 only |
TCR-294 |
|
|
– Downlink information for each radio link |
A6 |
Not Present |
TCR-295 |
|
|
MBMS PL Service Restriction Information |
A1, A2, A3, A4, A5, A6 |
Not Present |
Rel-6 |
TCR-296 |
|
Condition |
Explanation |
|
A1 |
This IE need for "Non speech in CS" |
|
A2 |
This IE need for "Speech in CS" |
|
A3 |
This IE need for "Packet to CELL_DCH from CELL_DCH in PS" |
|
A4 |
This IE need for "Packet to CELL_DCH from CELL_FACH in PS" |
|
A5 |
This IE need for "Packet to CELL_FACH from CELL_DCH in PS" |
|
A6 |
This IE need for "Packet to CELL_FACH from CELL_FACH in PS" |
Contents of TRANSPORT CHANNEL RECONFIGURATION COMPLETE message: AM
|
Information Element |
Value/remark |
|---|---|
|
Message Type |
|
|
RRC transaction identifier |
Checked to see if the value is identical to the same IE in the downlink TRANSPORT CHANNEL RECONFIGURATION message |
|
Integrity check info |
|
|
– Message authentication code |
This IE is checked to see if it is present. The value is compared against the XMAC-I value computed by SS. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
|
– RRC Message sequence number |
This IE is checked to see if it is present. The value is used by SS to compute the XMAC-I value. |
|
Uplink integrity protection activation info |
Not checked |
|
CHOICE mode |
FDD |
|
Deferred measurement control reading |
Not present for Rel-7 or later, otherwise Not checked |
|
COUNT-C activation time |
Not checked |
|
Radio bearer uplink ciphering activation time info |
Not checked |
|
Uplink counter synchronization info |
Not present |
Contents of TRANSPORT CHANNEL RECONFIGURATION FAILURE message: AM
|
Information Element |
Value/remark |
|
Message Type |
|
|
RRC transaction identifier |
Checked to see if it is set to identical value of the same IE in the downlink TRANSPORT CHANNEL RECONFIGURATION message. |
|
Integrity check info |
|
|
– Message authentication code |
This IE is checked to see if it is present. The value is compared against the XMAC-I value computed by SS. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
|
– RRC Message sequence number |
This IE is checked to see if it is present. The value is used by SS to compute the XMAC-I value. |
|
Failure cause |
Checked to see if it meets test requirement |
Contents of TRANSPORT FORMAT COMBINATION CONTROL message: AM or UM (in CELL_DCH)
|
Information Element |
Value/remark |
|
Message Type |
|
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
|
Integrity check info |
|
|
– Message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
|
– RRC Message sequence number |
SS provides the value of this IE, from its internal counter. |
|
CHOICE mode |
FDD |
|
DPCH/PUSCH TFCS in Uplink |
|
|
– CHOICE Subset representation |
Allowed transport format combination list |
|
– Allowed Transport format combination |
0 (The TFC is constructed from ALL TF0) |
|
Activation time for TFC subset |
Not Present |
|
TFC Control duration |
Not Present |
Contents of TRANSPORT FORMAT COMBINATION CONTROL FAILURE message: AM
|
Information Element |
Value/remark |
|
Message Type |
|
|
RRC transaction identifier |
Checked to see if it is set to identical value of the same IE in the downlink TRANSPORT CHANNEL RECONFIGURATION message. |
|
Integrity check info |
|
|
– Message authentication code |
This IE is checked to see if it is present. The value is compared against the XMAC-I value computed by SS. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
|
– RRC Message sequence number |
This IE is checked to see if it is present. The value is used by SS to compute the XMAC-I value. |
|
Failure cause |
Checked to see if it meets test requirement |
Contents of UE CAPABILITY ENQUIRY message: AM or UM
|
Information Element |
Value/remark |
|---|---|
|
Message Type |
|
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
|
Integrity check info |
|
|
– Message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
|
– RRC Message sequence number |
SS provides the value of this IE, from its internal counter. |
|
Capability update requirement |
|
|
– UE radio access FDD capability update requirement |
TRUE |
|
– UE radio access TDD capability update requirement |
FALSE |
|
– System specific capability update requirement list |
Not Present |
Contents of UE CAPABILITY INFORMATION message: AM
|
Information Element |
Value/remark |
|---|---|
|
Message Type |
|
|
RRC transaction identifier |
Checked to see if the value is identical to the same IE in the downlink UE CAPABILITY ENQUIRY message. |
|
Integrity check info |
|
|
– Message authentication code |
This IE is checked to see if it is present. The value is compared against the XMAC-I value computed by SS. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
|
– RRC Message sequence number |
This IE is checked to see if it is present. The value is used by SS to compute the XMAC-I value. |
|
UE radio access capability |
Value will be checked. Stated capability must be compatible with 3GPP TS 34.123-2 [3] (ICS statements) and the user settings |
|
– Access stratum release indicator |
|
|
– PDCP Capability |
|
|
– RLC Capability |
|
|
– Transport channel capability |
|
|
– RF Capability FDD |
|
|
– RF Capability TDD |
|
|
– Physical channel capability |
|
|
– UE multi-mode/multi-RAT capability |
|
|
– Security Capability |
|
|
– UE positioning Capability |
|
|
– Measurement capability |
|
|
UE radio access capability extension |
Value will be checked. Stated capability must be compatible with 3GPP TS 34.123-2 [3] (ICS statements) and the user settings |
|
UE system specific capability |
Not Checked |
Contents of UE CAPABILITY INFORMATION CONFIRM message: AM or UM
|
Information Element |
Value/remark |
|
Message Type |
|
|
RRC transaction identifier |
Set to the same value as received in the UE CAPABILITY INFORMATON message. |
|
Integrity check info |
|
|
– Message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
|
– RRC Message sequence number |
SS provides the value of this IE, from its internal counter. |
Contents of UE INFORMATION REQUEST: AM
|
Information Element |
Condition |
Value/remark |
Version |
|---|---|---|---|
|
Message Type |
Rel-10 |
||
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Rel-10 |
|
|
Integrity check info |
Rel-10 |
||
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
||
|
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
||
|
Logged Measurements Report Request |
A1 |
Not Present |
Rel-10 |
|
Logged ANR Report Request |
A1 |
TRUE |
Rel-10 |
|
Condition |
Explanation |
Version |
|
A1 |
Configuring of IE for requesting Logged ANR Report |
Rel-10 |
Contents of UE INFORMATION RESPONSE: AM
|
Information Element |
Value/remark |
Version |
|---|---|---|
|
Message Type |
Rel-10 |
|
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
Rel-10 |
|
Integrity check info |
Rel-10 |
|
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
|
|
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
|
|
Logged Meas Report |
Not Checked |
Rel-10 |
|
Logged ANR Report Info |
Not Checked |
Rel-10 |
Contents of URA UPDATE message: TM
|
Information Element |
Value/remark |
Version |
|---|---|---|
|
Message Type |
||
|
U-RNTI |
||
|
– SRNC identity |
0000 0000 0001B |
|
|
– S-RNTI |
0000 0000 0000 0000 0001B |
|
|
RRC transaction identifier |
Checked to see if it is absent |
|
|
Integrity check info |
||
|
– Message authentication code |
This IE is checked to see if it is present. The value is compared against the XMAC-I value computed by SS. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
|
|
– RRC Message sequence number |
This IE is checked to see if it is present. The value is used by SS to compute the XMAC-I value. |
|
|
URA update cause |
See the test content |
|
|
Protocol error indicator |
Checked to see if it is absent or set to ‘FALSE’ |
|
|
HS-PDSCH in CELL_PCH and URA_PCH |
Not checked |
|
|
HS-PDSCH in CELL_FACH |
Not checked |
|
|
Protocol error information |
Checked to see if it is absent |
|
|
Logged Meas Available |
Not checked |
Rel-10 |
Contents of URA UPDATE CONFIRM message: UM
|
Information Element |
Value/remark |
Version |
|
Message Type |
||
|
U-RNTI |
If this message is sent on CCCH, use the following values. Else, this IE is absent. |
|
|
– SRNC identity |
0000 0000 0001B |
|
|
– S-RNTI |
0000 0000 0000 0000 0001B |
|
|
RRC transaction identifier |
Arbitrarily selects and integer between 0 and 3 |
|
|
Integrity check info |
||
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
|
|
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
|
|
Integrity protection mode info |
Not Present |
|
|
Ciphering mode info |
Not Present |
|
|
New U-RNTI |
Not Present |
|
|
New C-RNTI |
Not Present |
|
|
RRC state indicator |
URA_PCH |
|
|
UTRAN DRX cycle length coefficient |
3 |
|
|
CN information info |
Not Present |
|
|
URA identity |
Not Present |
|
|
RNC support for change of UE capability |
Not Present |
|
|
Downlink counter synchronization info |
Not Present |
|
|
Logged Meas Available |
Not Present |
Rel-10 |
|
ANR Logging Results Available |
Not Present |
Rel-10 |
Contents of UPLINK DIRECT TRANSFER message: AM
|
Information Element |
Value/remark |
|
Message Type |
|
|
Integrity check info |
|
|
– Message authentication code |
This IE is checked to see if it is present. The value is compared against the XMAC-I value computed by SS. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
|
– RRC Message sequence number |
This IE is checked to see if it is present. The value is used by SS to compute the XMAC-I value. |
|
CN domain identity |
Checked to see if set to a CN domain for which a signalling connection exists |
|
NAS message |
Set according to that indicated in specific message content clause |
|
Measured results on RACH |
Not checked |
Contents of UTRAN MOBILITY INFORMATION message: AM or UM
|
Information Element |
Condition |
Value/remark |
|
Message Type |
||
|
Integrity check info |
||
|
– message authentication code |
SS calculates the value of MAC-I for this message and writes to this IE. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
|
|
– RRC message sequence number |
SS provides the value of this IE, from its internal counter. |
|
|
RRC transaction identifier |
Arbitrarily selects an integer between 0 and 3 |
|
|
Integrity protection mode info |
Not Present |
|
|
Ciphering mode info |
Not Present |
|
|
New U-RNTI |
See the test content |
|
|
New C-RNTI |
See the test content |
|
|
New H-RNTI |
Not Present |
|
|
UE Timers and constants in connected mode |
||
|
– T301 |
2 000 milliseconds |
|
|
– N301 |
2 |
|
|
– T302 |
4 000 milliseconds |
|
|
– N302 |
3 |
|
|
– T304 |
1 000 milliseconds |
|
|
– N304 |
3 |
|
|
– T305 |
60 minutes |
|
|
– T307 |
50 seconds |
|
|
– T308 |
320 milliseconds |
|
|
– T309 |
8 seconds |
|
|
– T310 |
320 milliseconds |
|
|
– N310 |
5 |
|
|
– T311 |
500 milliseconds |
|
|
– T312 |
5 seconds |
|
|
– N312 |
200 |
|
|
– T313 |
10 seconds |
|
|
– N313 |
200 |
|
|
– T314 |
20 seconds |
|
|
– T315 |
30 seconds |
|
|
– N315 |
200 |
|
|
– T316 |
50 seconds |
|
|
– T317 |
1 800 seconds |
|
|
CN information info |
Not Present |
|
|
URA identity |
Not present |
|
|
RNC support for change of UE capability |
Not Present |
|
|
Downlink counter synchronization info |
Not Present |
|
|
Dedicated WLAN Offload Information |
WLAN |
|
|
– CHOICE Configuration info |
New configuration |
|
|
– T330 |
10 |
|
|
– WLAN Offload Information |
||
|
– WLAN Offload Configuration |
||
|
-Threshold Serving RSCP |
RSCP |
|
|
-ThreshservingOffloadWLAN, low |
Set according to specific message content |
|
|
-ThreshservingOffloadWLAN, high |
Set according to specific message content |
|
|
-Threshold Serving Ec/N0 |
Ec/No |
|
|
-ThreshservingOffloadWLAN, low2 |
Set according to specific message content |
|
|
-ThreshservingOffloadWLAN, high2 |
Set according to specific message content |
|
|
-Threshold Channel Utilization |
ChannelUtilization |
|
|
-ThreshchUtilWLAN, low |
Set according to specific message content |
|
|
-ThreshchUtilWLAN, high |
Set according to specific message content |
|
|
-Threshold Backhaul Bandwidth |
BackHaul |
|
|
-ThreshbackhRateDLWLAN, low |
Set according to specific message content |
|
|
-ThreshbackhRateDLWLAN, high |
Set according to specific message content |
|
|
-ThreshbackhRateULWLAN, low |
Set according to specific message content |
|
|
-ThreshbackhRateULWLAN, high |
Set according to specific message content |
|
|
-Threshold Beacon RSSI |
RSSI |
|
|
-ThreshBeaconRSSIWLAN, low |
Set according to specific message content |
|
|
-ThreshBeaconRSSIWLAN, high |
Set according to specific message content |
|
|
-Offload Preference Indicator |
‘1111 1111 1111 1111’B |
|
|
-TsteeringWLAN |
0 |
|
|
-WLAN Identifier List |
Only 1 WLAN identifier bradcasted |
|
|
– WLAN Identifier |
||
|
– WLAN Type ID |
||
|
– SSID |
Set as per Table 4.4.8-1 of 36.508[45] |
|
|
-BSSID |
Not Present |
|
|
-HESSID |
Not Present |
|
Condition |
Explanation |
|
WLAN |
RAN Assisted WLAN interworking test cases |
|
RSCP |
RSCP based thresholds are to be used |
|
Ec/No |
Ec/No based thresholds are to be used |
|
ChannelUtilization |
Channel Utilization based thresholds are to be used |
|
BackHaul |
BackHaul Bandwidth based thresholds are to be used |
|
RSSI |
Beacon RSSI based thresholds are to be used |
Contents of UTRAN MOBILITY INFORMATION CONFIRM message: AM
|
Information Element |
Value/remark |
|
Message Type |
|
|
RRC transaction identifier |
Checked to see if it matches the value of the same IE in downlink UTRAN MOBILITY INFORMATION message |
|
Integrity check info |
|
|
– Message authentication code |
This IE is checked to see if it is present. The value is compared against the XMAC-I value computed by SS. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
|
– RRC Message sequence number |
This IE is checked to see if it is present. The value is used by SS to compute the XMAC-I value. |
|
Uplink integrity protection activation info |
Not checked |
|
Deferred measurement control reading |
Not Present for Rel-7 or later, otherwise Not checked |
|
COUNT-C activation time |
Not checked |
|
Radio bearer uplink ciphering activation time info |
Not checked |
|
Uplink counter synchronization info |
Not present |
Contents of UTRAN MOBILITY INFORMATION FAILURE message: AM
|
Information Element |
Value/remark |
|
Message Type |
|
|
RRC transaction identifier |
Checked to see if it matches the value of the same IE in downlink UTRAN MOBILITY INFORMATION message |
|
Integrity check info |
|
|
– Message authentication code |
This IE is checked to see if it is present. The value is compared against the XMAC-I value computed by SS. The first/ leftmost bit of the bit string contains the most significant bit of the MAC-I. |
|
– RRC Message sequence number |
This IE is checked to see if it is present. The value is used by SS to compute the XMAC-I value. |
|
Failure Cause |
Checked to see if it meets test requirement |