6.1.4 Default parameters for 1 to 8 cell environments
34.1083GPPCommon test environments for User Equipment (UE)Conformance testingRelease 15TS
Default settings for cell No.1 (FDD)
|
Downlink input level |
Reference clause 6.10 "Parameter Set" |
|
Uplink output power |
Minimum supported by the UE’s power class. |
|
PCCPCH/PCPICH carrier number |
Reference clause 6.10 "Parameter Set" |
|
Cell Channel Description |
|
|
– Primary CPICH info |
|
|
– Primary scrambling code |
100 |
Contents of System Information Block type 11 for cell No.1 (FDD)
See clause 6.1.0b for contents of System Information Block type 11 (FDD) for cell 1.
Contents of System Information Block type 12 in connected mode for cell No.1 (FDD)
See clause 6.1.0b for contents of System Information Block type 12 (FDD) for cell 1.
Default settings for cell No.1 (TDD)
|
Downlink input level |
Reference clause 6 Parameter Set |
|
Uplink output power |
Minimum supported by the UE’s power class. |
|
PCCPCH/PCPICH carrier number |
Reference clause 6 Parameter Set |
|
Cell Channel Description |
|
|
– Primary CCPCH info |
|
|
– Cell parameters ID |
0 |
Contents of System Information Block type 11 for cell No.1 (TDD)
See clause 6.1.0b for contents of System Information Block type 11 (TDD) for cell 1.
Contents of System Information Block type 12 in connected mode for cell No.1 (TDD)
See clause 6.1.0b for contents of System Information Block type 12 (TDD) for cell 1.
Cell No.2
The contents of SYSTEM INFORMATION BLOCK TYPE 1 to 16 messages for cell No.2 are identical to those of cell No.1 with the following exceptions.
|
Cell identity |
0000 0000 0000 0000 0000 0000 0010B |
|
URA identity |
0000 0000 0000 0001B |
Default settings for cell No.2 (FDD)
|
Downlink input level |
Reference clause 6.10 "Parameter Set" |
|
Uplink output power |
Minimum supported by the UE’s power class. |
|
PCCPCH/PCPICH carrier number |
Reference clause 6.10 "Parameter Set" |
|
Cell Channel Description |
|
|
– Primary CPICH info |
|
|
– Primary scrambling code |
150 |
Contents of System Information Block type 11 for cell No.2 (FDD)
|
– Intra-frequency measurement system information |
A1, A2, A3 |
|
|
…. |
||
|
– New intra-frequency cells |
||
|
– Intra-frequency cell id |
2 |
|
|
– Cell info |
Same content as specified for Intra-frequency cell id=1 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.2 (FDD)" in clause 6.1.4 |
|
|
– Intra-frequency cell id |
1 |
|
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.1 (FDD)" in clause 6.1.4 |
|
|
– Intra-frequency cell id |
3 |
|
|
– Cell info |
Same content as specified for Intra-frequency cell id=3 in SIB11 for Cell 1 in clause 6.1.0b |
|
|
– Intra-frequency cell id |
A1, A3 |
7 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=7 in SIB11 for Cell 1 in clause 6.1.0b |
|
|
– Intra-frequency cell id |
8 |
|
|
– Cell info |
Same content as specified for Intra-frequency cell id=8 in SIB11 for Cell 1 in clause 6.1.0b |
|
|
– Intra-frequency cell id |
A3 |
11 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.11 (FDD)" in clause 6.1.4 |
|
|
….. |
||
|
– Inter-frequency measurement system information |
A1, A2 |
|
|
….. |
||
|
– New inter-frequency cells |
||
|
– Inter frequency cell id |
4 |
|
|
– Frequency info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b |
|
|
– Cell info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b |
|
|
– Inter frequency cell id |
5 |
|
|
– Frequency info |
Same content as specified for Inter-frequency cell id=5 in SIB11 for Cell 1 in clause 6.1.0b |
|
|
– Cell info |
Same content as specified for Inter-frequency cell id=5 in SIB11 for Cell 1 in clause 6.1.0b |
|
|
– Inter frequency cell id |
6 |
|
|
– Frequency info |
Same content as specified for Inter-frequency cell id=6 in SIB11 for Cell 1 in clause 6.1.0b |
|
|
– Cell info |
Same content as specified for Inter-frequency cell id=6 in SIB11 for Cell 1 in clause 6.1.0b |
|
|
….. |
||
|
– Inter-RAT cell info list |
A2 |
|
|
…. |
||
|
– New inter-RAT cells |
||
|
– Inter-RAT cell id |
9 |
|
|
– CHOICE Radio Access Technology |
GSM |
|
|
– GSM |
Same content as specified for inter-RAT cell id=9 in SIB11 for Cell 1 in clause 6.1.0b |
|
|
– Inter-RAT cell id |
10 |
|
|
– CHOICE Radio Access Technology |
GSM |
|
|
– GSM |
Same content as specified for inter-RAT cell id=10 in SIB11 for Cell 1 in clause 6.1.0b |
|
|
…. |
|
Condition |
Explanation |
|
A1 |
FDD cell environment |
|
A2 |
FDD/GSM inter-RAT cell environment |
|
A3 |
FDD intra-frequency cell environment (6 intra-frequency cells without inter-frequency cells) |
Default settings for cell No.2 (TDD)
|
Downlink input level |
Reference clause 6 Parameter Set |
|
Uplink output power |
Minimum supported by the UE’s power class. |
|
PCCPCH/PCPICH carrier number |
Reference clause 6 Parameter Set |
|
Cell Channel Description |
|
|
– Primary CCPCH info |
|
|
– Cell parameters ID |
4 |
Contents of System Information Block type 11 for cell No.2 (TDD)
|
– Intra-frequency measurement system information |
|
|
…. |
|
|
– New intra-frequency cells |
|
|
– Intra-frequency cell id |
2 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=1 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.2 (TDD)" in clause 6.1.4 |
|
– Intra-frequency cell id |
1 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.1 (TDD)" in clause 6.1.4 |
|
– Intra-frequency cell id |
3 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=3 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Intra-frequency cell id |
7 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=7 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Intra-frequency cell id |
8 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=8 in SIB11 for Cell 1 in clause 6.1.0b |
|
….. |
|
|
– Inter-frequency measurement system information |
|
|
….. |
|
|
– New inter-frequency cells |
|
|
– Inter frequency cell id |
4 |
|
– Frequency info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Cell info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Inter frequency cell id |
5 |
|
– Frequency info |
Same content as specified for Inter-frequency cell id=5 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Cell info |
Same content as specified for Inter-frequency cell id=5 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Inter frequency cell id |
6 |
|
– Frequency info |
Same content as specified for Inter-frequency cell id=6 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Cell info |
Same content as specified for Inter-frequency cell id=6 in SIB11 for Cell 1 in clause 6.1.0b |
|
….. |
Cell No.3
The contents of SYSTEM INFORMATION BLOCK TYPE 1 to 16 messages for cell No.3 are identical to those of cell No.1 with the following exceptions.
|
Cell identity |
0000 0000 0000 0000 0000 0000 0011B |
|
URA identity |
0000 0000 0000 0010B |
Default settings for cell No.3 (FDD)
|
Downlink input level |
Reference clause 6.10 "Parameter Set" |
|
Uplink output power |
Minimum supported by the UE’s power class. |
|
PCCPCH/PCPICH carrier number |
Reference clause 6.10 "Parameter Set" |
|
Cell Channel Description |
|
|
– Primary CPICH info |
|
|
– Primary scrambling code |
200 |
Contents of System Information Block type 11 for cell No.3 (FDD)
|
– Intra-frequency measurement system information |
A1, A2, A3 |
|||
|
…. |
||||
|
– New intra-frequency cells |
||||
|
– Intra-frequency cell id |
3 |
|||
|
– Cell info |
Same content as specified for Intra-frequency cell id=1 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.3 (FDD)" in clause 6.1.4 |
|||
|
– Intra-frequency cell id |
1 |
|||
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 (neighbour cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.1 (FDD)" in clause 6.1.4 |
|||
|
– Intra-frequency cell id |
2 |
|||
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 in SIB11 for Cell 1 in clause 6.1.0b |
|||
|
– Intra-frequency cell id |
A1, A3 |
7 |
||
|
– Cell info |
Same content as specified for Intra-frequency cell id=7 in SIB11 for Cell 1 in clause 6.1.0b |
|||
|
– Intra-frequency cell id |
8 |
|||
|
– Cell info |
Same content as specified for Intra-frequency cell id=8 in SIB11 for Cell 1 in clause 6.1.0b |
|||
|
– Intra-frequency cell id |
A3 |
11 |
||
|
– Cell info |
Same content as specified for Intra-frequency cell id=11 in SIB11 for Cell 1 in clause 6.1.0b |
|||
|
….. |
||||
|
– Inter-frequency measurement system information |
A1, A2 |
|||
|
….. |
||||
|
– New inter-frequency cells |
||||
|
– Inter frequency cell id |
4 |
|||
|
– Frequency info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b |
|||
|
– Cell info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b |
|||
|
– Inter frequency cell id |
5 |
|||
|
– Frequency info |
Not Present Absence of this IE is equivalent to value of the previous "frequency info" in the list. |
|||
|
– Cell info |
Same content as specified for Inter-frequency cell id=5 in SIB11 for Cell 1 in clause 6.1.0b |
|||
|
– Inter frequency cell id |
6 |
|||
|
– Frequency info |
Not Present Absence of this IE is equivalent to value of the previous "frequency info" in the list. |
|||
|
– Cell info |
Same content as specified for Inter-frequency cell id=6 in SIB11 for Cell 1 in clause 6.1.0b |
|||
|
….. |
||||
|
– Inter-RAT cell info list |
A2 |
|||
|
…. |
||||
|
– New inter-RAT cells |
||||
|
– Inter-RAT cell id |
9 |
|||
|
– CHOICE Radio Access Technology |
GSM |
|||
|
– GSM |
Same content as specified for inter-RAT cell id=9 in SIB11 for Cell 1 in clause 6.1.0b |
|||
|
– Inter-RAT cell id |
10 |
|||
|
– CHOICE Radio Access Technology |
GSM |
|||
|
– GSM |
Same content as specified for inter-RAT cell id=10 in SIB11 for Cell 1 in clause 6.1.0b |
|||
|
…. |
||||
|
Condition |
Explanation |
|
A1 |
FDD cell environment |
|
A2 |
FDD/GSM inter-RAT cell environment |
|
A3 |
FDD intra-frequency cell environment (6 intra-frequency cells without inter-frequency cells) |
Default settings for cell No.3 (TDD)
|
Downlink input level |
Reference clause 6 Parameter Set |
|
Uplink output power |
Minimum supported by the UE’s power class. |
|
PCCPCH/PCPICH carrier number |
Reference clause 6 Parameter Set |
|
Cell Channel Description |
|
|
– Primary CCPCH info |
|
|
– Cell parameters ID |
8 |
Contents of System Information Block type 11 for cell No.3 (TDD)
|
– Intra-frequency measurement system information |
|
|
…. |
|
|
– New intra-frequency cells |
|
|
– Intra-frequency cell id |
3 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=1 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.3 (TDD)" in clause 6.1.4 |
|
– Intra-frequency cell id |
1 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 (neighbour cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.1 (TDD)" in clause 6.1.4 |
|
– Intra-frequency cell id |
2 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Intra-frequency cell id |
7 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=7 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Intra-frequency cell id |
8 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=8 in SIB11 for Cell 1 in clause 6.1.0b |
|
….. |
|
|
– Inter-frequency measurement system information |
|
|
….. |
|
|
– New inter-frequency cells |
|
|
– Inter frequency cell id |
4 |
|
– Frequency info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Cell info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Inter frequency cell id |
5 |
|
– Frequency info |
Not Present Absence of this IE is equivalent to value of the previous "frequency info" in the list. |
|
– Cell info |
Same content as specified for Inter-frequency cell id=5 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Inter frequency cell id |
6 |
|
– Frequency info |
Not Present Absence of this IE is equivalent to value of the previous "frequency info" in the list. |
|
– Cell info |
Same content as specified for Inter-frequency cell id=6 in SIB11 for Cell 1 in clause 6.1.0b |
|
….. |
Cell No.4
The contents of SYSTEM INFORMATION BLOCK TYPE 1 to 16 messages for cell No.4 are identical to those of cell No.1 with the following exceptions.
|
Cell identity |
0000 0000 0000 0000 0000 0000 0100B |
|
URA identity |
0000 0000 0000 0010B |
Default settings for cell No.4 (FDD)
|
Downlink input level |
Reference clause 6.10 "Parameter Set" |
|
Uplink output power |
Minimum supported by the UE’s power class. |
|
PCCPCH/PCPICH carrier number |
Reference clause 6.10 "Parameter Set" |
|
Cell Channel Description |
|
|
– Primary CPICH info |
|
|
– Primary scrambling code |
250 |
Contents of System Information Block type 11 for cell No.4 (FDD)
|
– Intra-frequency measurement system information |
A1, A2 |
|
|
…. |
||
|
– New intra-frequency cells |
||
|
– Intra-frequency cell id |
4 |
|
|
– Cell info |
Same content as specified for Intra-frequency cell id=1 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.4 (FDD)" in clause 6.1.4 |
|
|
– Intra-frequency cell id |
5 |
|
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.5 (FDD)" in clause 6.1.4 |
|
|
– Intra-frequency cell id |
6 |
|
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.6 (FDD)" in clause 6.1.4 |
|
|
….. |
||
|
– Inter-frequency measurement system information |
A1, A2 |
|
|
….. |
||
|
– New inter-frequency cells |
||
|
– Inter-frequency cell id |
1 |
|
|
– Frequency info |
||
|
– UARFCN uplink(Nu) |
Not present Absence of this IE is equivalent to apply the default duplex distance defined for the operating frequency according to 25.101 |
|
|
– UARFCN downlink(Nd) |
Reference to table 6.1.2 for Cell 1 |
|
|
– Cell info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.1 (FDD)" in clause 6.1.4 |
|
|
– Inter-frequency cell id |
2 |
|
|
– Frequency info |
Not Present Absence of this IE is equivalent to value of the previous "frequency info" in the list. |
|
|
– Cell info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.2 (FDD)" in clause 6.1.4 |
|
|
– Inter-frequency cell id |
3 |
|
|
– Frequency info |
Not Present Absence of this IE is equivalent to value of the previous "frequency info" in the list. |
|
|
– Cell info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.3 (FDD)" in clause 6.1.4 |
|
|
– Inter-frequency cell id |
A1 |
7 |
|
– Frequency info |
Not Present Absence of this IE is equivalent to value of the previous "frequency info" in the list. |
|
|
– Cell info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.7 (FDD)" in clause 6.1.4 |
|
|
– Inter-frequency cell id |
8 |
|
|
– Frequency info |
Not Present Absence of this IE is equivalent to value of the previous "frequency info" in the list. |
|
|
– Cell info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.8 (FDD)" in clause 6.1.4 |
|
|
– Inter-RAT cell info list |
A2 |
|
|
…. |
||
|
– New inter-RAT cells |
||
|
– Inter-RAT cell id |
9 |
|
|
– CHOICE Radio Access Technology |
GSM |
|
|
– GSM |
Same content as specified for inter-RAT cell id=9 in SIB11 for Cell 1 in clause 6.1.0b |
|
|
– Inter-RAT cell id |
10 |
|
|
– CHOICE Radio Access Technology |
GSM |
|
|
– GSM |
Same content as specified for inter-RAT cell id=10 in SIB11 for Cell 1 in clause 6.1.0b |
|
|
…. |
|
Condition |
Explanation |
|
A1 |
FDD cell environment |
|
A2 |
FDD/GSM inter-RAT cell environment |
Default settings for cell No.4 (TDD)
|
Downlink input level |
Reference clause 6 Parameter Set |
|
Uplink output power |
Minimum supported by the UE’s power class. |
|
PCCPCH/PCPICH carrier number |
Reference clause 6 Parameter Set |
|
Cell Channel Description |
|
|
– Primary CCPCH info |
|
|
– Cell parameters ID |
12 |
Contents of System Information Block type 11 for cell No.4 (TDD)
|
– Intra-frequency measurement system information |
|
|
…. |
|
|
– New intra-frequency cells |
|
|
– Intra-frequency cell id |
4 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=1 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.4 (TDD)" in clause 6.1.4 |
|
– Intra-frequency cell id |
5 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.5 (TDD)" in clause 6.1.4 |
|
– Intra-frequency cell id |
6 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.6 (TDD)" in clause 6.1.4 |
|
….. |
|
|
– Inter-frequency measurement system information |
|
|
….. |
|
|
– New inter-frequency cells |
|
|
– Inter-frequency cell id |
1 |
|
– Frequency info |
|
|
– UARFCN downlink(Nt) |
Reference to table 6.1.7 for Cell 1 |
|
– Cell info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.1 (TDD)" in clause 6.1.4 |
|
– Inter-frequency cell id |
2 |
|
– Frequency info |
Not Present Absence of this IE is equivalent to value of the previous "frequency info" in the list. |
|
– Cell info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.2 (TDD)" in clause 6.1.4 |
|
– Inter-frequency cell id |
3 |
|
– Frequency info |
Not Present Absence of this IE is equivalent to value of the previous "frequency info" in the list. |
|
– Cell info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.3 (TDD)" in clause 6.1.4 |
|
– Inter-frequency cell id |
7 |
|
– Frequency info |
Not Present Absence of this IE is equivalent to value of the previous "frequency info" in the list. |
|
– Cell info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.7 (TDD)" in clause 6.1.4 |
|
– Inter-frequency cell id |
8 |
|
– Frequency info |
Not Present Absence of this IE is equivalent to value of the previous "frequency info" in the list. |
|
– Cell info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.8 (TDD)" in clause 6.1.4 |
Cell No.5
The contents of SYSTEM INFORMATION BLOCK TYPE 1 to 16 messages for cell No.5 are identical to those of cell No.4 with the following exceptions.
|
Cell identity |
0000 0000 0000 0000 0000 0000 0101B |
|
URA identity |
0000 0000 0000 0011B |
Default settings for cell No.5 (FDD)
|
Downlink input level |
Reference clause 6.10 "Parameter Set" |
|
Uplink output power |
Minimum supported by the UE’s power class. |
|
PCCPCH/PCPICH carrier number |
Reference clause 6.10 "Parameter Set" |
|
Cell Channel Description |
|
|
– Primary CPICH info |
|
|
– Primary scrambling code |
300 |
Contents of System Information Block type 11 for cell No.5 (FDD)
|
– Intra-frequency measurement system information |
A1, A2 |
|
|
…. |
||
|
– New intra-frequency cells |
||
|
– Intra-frequency cell id |
5 |
|
|
– Cell info |
Same content as specified for Intra-frequency cell id=1 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.5 (FDD)" in clause 6.1.4 |
|
|
– Intra-frequency cell id |
4 |
|
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.4 (FDD)" in clause 6.1.4 |
|
|
– Intra-frequency cell id |
6 |
|
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.6 (FDD)" in clause 6.1.4 |
|
|
….. |
||
|
– Inter-frequency measurement system information |
A1, A2 |
|
|
….. |
||
|
– New inter-frequency cells |
||
|
– Inter-frequency cell id |
1 |
|
|
– Frequency info |
||
|
– UARFCN uplink(Nu) |
Not present Absence of this IE is equivalent to apply the default duplex distance defined for the operating frequency according to 25.101 |
|
|
– UARFCN downlink(Nd) |
Reference to table 6.1.2 for Cell 1 |
|
|
– Cell info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.1 (FDD)" in clause 6.1.4 |
|
|
– Inter-frequency cell id |
2 |
|
|
– Frequency info |
Not Present Absence of this IE is equivalent to value of the previous "frequency info" in the list. |
|
|
– Cell info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.2 (FDD)" in clause 6.1.4 |
|
|
– Inter-frequency cell id |
3 |
|
|
– Frequency info |
Not Present Absence of this IE is equivalent to value of the previous "frequency info" in the list. |
|
|
– Cell info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.3 (FDD)" in clause 6.1.4 |
|
|
– Inter-frequency cell id |
A1 |
7 |
|
– Frequency info |
Not Present Absence of this IE is equivalent to value of the previous "frequency info" in the list. |
|
|
– Cell info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.7 (FDD)" in clause 6.1.4 |
|
|
– Inter-frequency cell id |
8 |
|
|
– Frequency info |
Not Present Absence of this IE is equivalent to value of the previous "frequency info" in the list. |
|
|
– Cell info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.8 (FDD)" in clause 6.1.4 |
|
|
….. |
||
|
– Inter-RAT cell info list |
A2 |
|
|
…. |
||
|
– New inter-RAT cells |
||
|
– Inter-RAT cell id |
9 |
|
|
– CHOICE Radio Access Technology |
GSM |
|
|
– GSM |
Same content as specified for inter-RAT cell id=9 in SIB11 for Cell 1 in clause 6.1.0b |
|
|
– Inter-RAT cell id |
10 |
|
|
– CHOICE Radio Access Technology |
GSM |
|
|
– GSM |
Same content as specified for inter-RAT cell id=10 in SIB11 for Cell 1 in clause 6.1.0b |
|
|
…. |
|
Condition |
Explanation |
|
A1 |
FDD cell environment |
|
A2 |
FDD/GSM inter-RAT cell environment |
Default settings for cell No.5 (TDD)
|
Downlink input level |
Reference clause 6 Parameter Set |
|
Uplink output power |
Minimum supported by the UE’s power class. |
|
PCCPCH/PCPICH carrier number |
Reference clause 6 Parameter Set |
|
Cell Channel Description |
|
|
– Primary CCPCH info |
|
|
– Cell parameters ID |
114 |
Contents of System Information Block type 11 for cell No.5 (TDD)
|
– Intra-frequency measurement system information |
|
|
…. |
|
|
– New intra-frequency cells |
|
|
– Intra-frequency cell id |
5 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=1 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.5 (TDD)" in clause 6.1.4 |
|
– Intra-frequency cell id |
4 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.4 (TDD)" in clause 6.1.4 |
|
– Intra-frequency cell id |
6 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.6 (TDD)" in clause 6.1.4 |
|
….. |
|
|
– Inter-frequency measurement system information |
|
|
….. |
|
|
– New inter-frequency cells |
|
|
– Inter-frequency cell id |
1 |
|
– Frequency info |
|
|
– UARFCN downlink(Nt) |
Reference to table 6.1.7 for Cell 1 |
|
– Cell info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.1 (TDD)" in clause 6.1.4 |
|
– Inter-frequency cell id |
2 |
|
– Frequency info |
Not Present Absence of this IE is equivalent to value of the previous "frequency info" in the list. |
|
– Cell info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.2 (TDD)" in clause 6.1.4 |
|
– Inter-frequency cell id |
3 |
|
– Frequency info |
Not Present Absence of this IE is equivalent to value of the previous "frequency info" in the list. |
|
– Cell info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.3 (TDD)" in clause 6.1.4 |
|
– Inter-frequency cell id |
7 |
|
– Frequency info |
Not Present Absence of this IE is equivalent to value of the previous "frequency info" in the list. |
|
– Cell info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.7 (TDD)" in clause 6.1.4 |
|
– Inter-frequency cell id |
8 |
|
– Frequency info |
Not Present Absence of this IE is equivalent to value of the previous "frequency info" in the list. |
|
– Cell info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.8 (TDD)" in clause 6.1.4 |
Cell No.6
The contents of SYSTEM INFORMATION BLOCK TYPE 1 to 16 messages for cell No.6 are identical to those of cell No.4 with the following exceptions:
|
Cell identity |
0000 0000 0000 0000 0000 0000 0110B |
|
URA identity |
0000 0000 0000 0011B |
Default settings for cell No.6 (FDD)
|
Downlink input level |
Reference clause 6 Parameter Set |
|
Uplink output power |
Minimum supported by the UE’s power class. |
|
PCCPCH/PCPICH carrier number |
Reference clause 6 Parameter Set |
|
Cell Channel Description |
|
|
– Primary CPICH info |
|
|
– Primary scrambling code |
350 |
Contents of System Information Block type 11 for cell No.6 (FDD)
|
– Intra-frequency measurement system information |
A1, A2 |
|
|
…. |
||
|
– New intra-frequency cells |
||
|
– Intra-frequency cell id |
6 |
|
|
– Cell info |
Same content as specified for Intra-frequency cell id=1 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.6 (FDD)" in clause 6.1.4 |
|
|
– Intra-frequency cell id |
4 |
|
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.4 (FDD)" in clause 6.1.4 |
|
|
– Intra-frequency cell id |
5 |
|
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.5 (FDD)" in clause 6.1.4 |
|
|
….. |
||
|
– Inter-frequency measurement system information |
A1, A2 |
|
|
….. |
||
|
– New inter-frequency cells |
||
|
– Inter-frequency cell id |
1 |
|
|
– Frequency info |
||
|
– UARFCN uplink(Nu) |
Not present Absence of this IE is equivalent to apply the default duplex distance defined for the operating frequency according to 3GPP TS 25.101 [11] |
|
|
– UARFCN downlink(Nd) |
Reference to table 6.1.2 for Cell 1 |
|
|
– Cell info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.1 (FDD)" in clause 6.1.4 |
|
|
– Inter-frequency cell id |
2 |
|
|
– Frequency info |
Not Present Absence of this IE is equivalent to value of the previous "frequency info" in the list. |
|
|
– Cell info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.2 (FDD)" in clause 6.1.4 |
|
|
– Inter-frequency cell id |
3 |
|
|
– Frequency info |
Not Present Absence of this IE is equivalent to value of the previous "frequency info" in the list. |
|
|
– Cell info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.3 (FDD)" in clause 6.1.4 |
|
|
– Inter-frequency cell id |
A1 |
7 |
|
– Frequency info |
Not Present Absence of this IE is equivalent to value of the previous "frequency info" in the list. |
|
|
– Cell info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.7 (FDD)" in clause 6.1.4 |
|
|
– Inter-frequency cell id |
8 |
|
|
– Frequency info |
Not Present Absence of this IE is equivalent to value of the previous "frequency info" in the list. |
|
|
– Cell info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.8 (FDD)" in clause 6.1.4 |
|
|
….. |
||
|
– Inter-RAT cell info list |
A2 |
|
|
…. |
||
|
– New inter-RAT cells |
||
|
– Inter-RAT cell id |
9 |
|
|
– CHOICE Radio Access Technology |
GSM |
|
|
– GSM |
Same content as specified for inter-RAT cell id=9 in SIB11 for Cell 1 in clause 6.1.0b |
|
|
– Inter-RAT cell id |
10 |
|
|
– CHOICE Radio Access Technology |
GSM |
|
|
– GSM |
Same content as specified for inter-RAT cell id=10 in SIB11 for Cell 1 in clause 6.1.0b |
|
|
…. |
|
Condition |
Explanation |
|
A1 |
FDD cell environment |
|
A2 |
FDD/GSM inter-RAT cell environment |
Default settings for cell No.6 (TDD)
|
Downlink input level |
Reference clause 6 Parameter Set |
|
Uplink output power |
Minimum supported by the UE’s power class. |
|
PCCPCH/PCPICH carrier number |
Reference clause 6 Parameter Set |
|
Cell Channel Description |
|
|
– Primary CCPCH info |
|
|
– Cell parameters ID |
119 |
Contents of System Information Block type 11 for cell No.6 (TDD)
|
– Intra-frequency measurement system information |
|
|
…. |
|
|
– New intra-frequency cells |
|
|
– Intra-frequency cell id |
6 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=1 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.6 (TDD)" in clause 6.1.4 |
|
– Intra-frequency cell id |
4 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.4 (TDD)" in clause 6.1.4 |
|
– Intra-frequency cell id |
5 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.5 (TDD)" in clause 6.1.4 |
|
….. |
|
|
– Inter-frequency measurement system information |
|
|
….. |
|
|
– New inter-frequency cells |
|
|
– Inter-frequency cell id |
1 |
|
– Frequency info |
|
|
– UARFCN downlink(Nt) |
Reference to table 6.1.7 for Cell 1 |
|
– Cell info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.1 (TDD)" in clause 6.1.4 |
|
– Inter-frequency cell id |
2 |
|
– Frequency info |
Not Present Absence of this IE is equivalent to value of the previous "frequency info" in the list. |
|
– Cell info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.2 (TDD)" in clause 6.1.4 |
|
– Inter-frequency cell id |
3 |
|
– Frequency info |
Not Present Absence of this IE is equivalent to value of the previous "frequency info" in the list. |
|
– Cell info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.3 (TDD)" in clause 6.1.4 |
|
– Inter-frequency cell id |
7 |
|
– Frequency info |
Not Present Absence of this IE is equivalent to value of the previous "frequency info" in the list. |
|
– Cell info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.7 (TDD)" in clause 6.1.4 |
|
– Inter-frequency cell id |
8 |
|
– Frequency info |
Not Present Absence of this IE is equivalent to value of the previous "frequency info" in the list. |
|
– Cell info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.8 (TDD)" in clause 6.1.4 |
|
….. |
Cell No.7
The contents of SYSTEM INFORMATION BLOCK TYPE 1 to 16 messages for cell No.7 are identical to those of cell No.1 with the following exceptions.
|
Cell identity |
0000 0000 0000 0000 0000 0000 0111B |
|
URA identity |
0000 0000 0000 0100B |
Default settings for cell No.7 (FDD)
|
Downlink input level |
Reference clause 6.10 "Parameter Set" |
|
Uplink output power |
Minimum supported by the UE’s power class. |
|
PCCPCH/PCPICH carrier number |
Reference clause 6.10 "Parameter Set" |
|
Cell Channel Description |
|
|
– Primary CPICH info |
|
|
– Primary scrambling code |
400 |
Contents of System Information Block type 11 for cell No.7 (FDD)
|
– Intra-frequency measurement system information |
A1, A3 |
|
|
…. |
||
|
– New intra-frequency cells |
||
|
– Intra-frequency cell id |
7 |
|
|
– Cell info |
Same content as specified for Intra-frequency cell id=1 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.7 (FDD)" in clause 6.1.4 |
|
|
– Intra-frequency cell id |
1 |
|
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 (neighbour cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.1 (FDD)" in clause 6.1.4 |
|
|
– Intra-frequency cell id |
2 |
|
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 in SIB11 for Cell 1 in clause 6.1.0b |
|
|
– Intra-frequency cell id |
3 |
|
|
– Cell info |
Same content as specified for Intra-frequency cell id=3 in SIB11 for Cell 1 in clause 6.1.0b |
|
|
– Intra-frequency cell id |
8 |
|
|
– Cell info |
Same content as specified for Intra-frequency cell id=8 in SIB11 for Cell 1 in clause 6.1.0b |
|
|
– Intra-frequency cell id |
A3 |
11 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=11 in SIB11 for Cell 1 in clause 6.1.0b |
|
|
….. |
||
|
– Inter-frequency measurement system information |
A1 |
|
|
….. |
||
|
– New inter-frequency cells |
||
|
– Inter frequency cell id |
4 |
|
|
– Frequency info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b |
|
|
– Cell info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b |
|
|
– Inter frequency cell id |
5 |
|
|
– Frequency info |
Same content as specified for Inter-frequency cell id=5 in SIB11 for Cell 1 in clause 6.1.0b |
|
|
– Cell info |
Same content as specified for Inter-frequency cell id=5 in SIB11 for Cell 1 in clause 6.1.0b |
|
|
– Inter frequency cell id |
6 |
|
|
– Frequency info |
Same content as specified for Inter-frequency cell id=6 in SIB11 for Cell 1 in clause 6.1.0b |
|
|
– Cell info |
Same content as specified for Inter-frequency cell id=6 in SIB11 for Cell 1 in clause 6.1.0b |
|
|
….. |
|
Condition |
Explanation |
|
A1 |
FDD cell environment |
|
A2 |
FDD/GSM inter-RAT cell environment |
|
A3 |
FDD intra-frequency cell environment (6 intra-frequency cells without inter-frequency cells) |
Default settings for cell No.7 (TDD)
|
Downlink input level |
Reference clause 6 Parameter Set |
|
Uplink output power |
Minimum supported by the UE’s power class. |
|
PCCPCH/PCPICH carrier number |
Reference clause 6 Parameter Set |
|
Cell Channel Description |
|
|
– Primary CCPCH info |
|
|
– Cell parameters ID |
123 |
Contents of System Information Block type 11 for cell No.7 (TDD)
|
– Intra-frequency measurement system information |
|
|
…. |
|
|
– New intra-frequency cells |
|
|
– Intra-frequency cell id |
7 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=1 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.7 (TDD)" in clause 6.1.4 |
|
– Intra-frequency cell id |
1 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 (neighbour cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.1 (TDD)" in clause 6.1.4 |
|
– Intra-frequency cell id |
2 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Intra-frequency cell id |
3 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=3 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Intra-frequency cell id |
8 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=8 in SIB11 for Cell 1 in clause 6.1.0b |
|
….. |
|
|
– Inter-frequency measurement system information |
|
|
….. |
|
|
– New inter-frequency cells |
|
|
– Inter frequency cell id |
4 |
|
– Frequency info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Cell info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Inter frequency cell id |
5 |
|
– Frequency info |
Same content as specified for Inter-frequency cell id=5 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Cell info |
Same content as specified for Inter-frequency cell id=5 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Inter frequency cell id |
6 |
|
– Frequency info |
Same content as specified for Inter-frequency cell id=6 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Cell info |
Same content as specified for Inter-frequency cell id=6 in SIB11 for Cell 1 in clause 6.1.0b |
|
….. |
Cell No.8
The contents of SYSTEM INFORMATION BLOCK TYPE 1 to 16 messages for cell No.8 are identical to those of cell No.1 with the following exceptions:
|
Cell identity |
0000 0000 0000 0000 0000 0000 1000B |
|
URA identity |
0000 0000 0000 0100B |
Default settings for cell No.8 (FDD)
|
Downlink input level |
Reference clause 6.10 "Parameter Set" |
|
Uplink output power |
Minimum supported by the UE’s power class. |
|
PCCPCH/PCPICH carrier number |
Reference clause 6.10 "Parameter Set" |
|
Cell Channel Description |
|
|
– Primary CPICH info |
|
|
– Primary scrambling code |
450 |
Contents of System Information Block type 11 for cell No.8 (FDD)
|
– Intra-frequency measurement system information |
A1, A3 |
|
|
…. |
||
|
– New intra-frequency cells |
||
|
– Intra-frequency cell id |
8 |
|
|
– Cell info |
Same content as specified for Intra-frequency cell id=1 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.8 (FDD)" in clause 6.1.4 |
|
|
– Intra-frequency cell id |
1 |
|
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 (neighbour cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.1 (FDD)" in clause 6.1.4 |
|
|
– Intra-frequency cell id |
2 |
|
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 in SIB11 for Cell 1 in clause 6.1.0b |
|
|
– Intra-frequency cell id |
3 |
|
|
– Cell info |
Same content as specified for Intra-frequency cell id=3 in SIB11 for Cell 1 in clause 6.1.0b |
|
|
– Intra-frequency cell id |
7 |
|
|
– Cell info |
Same content as specified for Intra-frequency cell id=7 in SIB11 for Cell 1 in clause 6.1.0b |
|
|
– Intra-frequency cell id |
A3 |
11 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=11 in SIB11 for Cell 1 in clause 6.1.0b |
|
|
….. |
||
|
– Inter-frequency measurement system information |
A1 |
|
|
….. |
||
|
– New inter-frequency cells |
||
|
– Inter frequency cell id |
4 |
|
|
– Frequency info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b |
|
|
– Cell info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b |
|
|
– Inter frequency cell id |
5 |
|
|
– Frequency info |
Same content as specified for Inter-frequency cell id=5 in SIB11 for Cell 1 in clause 6.1.0b |
|
|
– Cell info |
Same content as specified for Inter-frequency cell id=5 in SIB11 for Cell 1 in clause 6.1.0b |
|
|
– Inter frequency cell id |
6 |
|
|
– Frequency info |
Same content as specified for Inter-frequency cell id=6 in SIB11 for Cell 1 in clause 6.1.0b |
|
|
– Cell info |
Same content as specified for Inter-frequency cell id=6 in SIB11 for Cell 1 in clause 6.1.0b |
|
|
….. |
|
Condition |
Explanation |
|
A1 |
FDD cell environment |
|
A2 |
FDD/GSM inter-RAT cell environment |
|
A3 |
FDD intra-frequency cell environment (6 intra-frequency cells without inter-frequency cells) |
Default settings for cell No.8 (TDD)
|
Downlink input level |
Reference clause 6 Parameter Set |
|
Uplink output power |
Minimum supported by the UE’s power class. |
|
PCCPCH/PCPICH carrier number |
Reference clause 6 Parameter Set |
|
Cell Channel Description |
|
|
– Primary CCPCH info |
|
|
– Cell parameters ID |
127 |
Contents of System Information Block type 11 for cell No.8 (TDD)
|
– Intra-frequency measurement system information |
|
|
…. |
|
|
– New intra-frequency cells |
|
|
– Intra-frequency cell id |
8 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=1 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.8 (TDD)" in clause 6.1.4 |
|
– Intra-frequency cell id |
1 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 (neighbour cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.1 (TDD)" in clause 6.1.4 |
|
– Intra-frequency cell id |
2 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Intra-frequency cell id |
3 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=3 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Intra-frequency cell id |
7 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=7 in SIB11 for Cell 1 in clause 6.1.0b |
|
….. |
|
|
– Inter-frequency measurement system information |
|
|
….. |
|
|
– New inter-frequency cells |
|
|
– Inter frequency cell id |
4 |
|
– Frequency info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Cell info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Inter frequency cell id |
5 |
|
– Frequency info |
Same content as specified for Inter-frequency cell id=5 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Cell info |
Same content as specified for Inter-frequency cell id=5 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Inter frequency cell id |
6 |
|
– Frequency info |
Same content as specified for Inter-frequency cell id=6 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Cell info |
Same content as specified for Inter-frequency cell id=6 in SIB11 for Cell 1 in clause 6.1.0b |
|
….. |
Cell No.9
Contents of System Information for cell No.9 (GSM)
See 3GPP TS 51.010-1 [31], clause 10.1.2.
Default settings for cell No.9 (GSM)
See table 6.1.10.
Cell No.10
Contents of System Information for cell No.10 (GSM)
See 3GPP TS 51.010-1 [31], clause 10.1.2.
Default settings for cell No.10 (GSM)
See table 6.1.10
Cell No.11
The contents of SYSTEM INFORMATION BLOCK TYPE 1 to 16 messages for cell No.11 are identical to those of cell No.1 with the following exceptions.
|
Cell identity |
0000 0000 0000 0000 0000 0000 1011B |
|
URA identity |
0000 0000 0000 0010B |
Default settings for cell No.11 (FDD)
|
Downlink input level |
Reference clause 6.10 "Parameter Set" |
|
Uplink output power |
Minimum supported by the UE’s power class. |
|
PCCPCH/PCPICH carrier number |
Reference clause 6.10 "Parameter Set" |
|
Cell Channel Description |
|
|
– Primary CPICH info |
|
|
– Primary scrambling code |
500 |
Contents of System Information Block type 11 for cell No.11 (FDD)
|
– Intra-frequency measurement system information |
A3 |
|
|
…. |
||
|
– New intra-frequency cells |
||
|
– Intra-frequency cell id |
11 |
|
|
– Cell info |
Same content as specified for Intra-frequency cell id=1 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.11 (FDD)" in clause 6.1.4 |
|
|
– Intra-frequency cell id |
1 |
|
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 (neighbour cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.1 (FDD)" in clause 6.1.4 |
|
|
– Intra-frequency cell id |
2 |
|
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 in SIB11 for Cell 1 in clause 6.1.0b |
|
|
– Intra-frequency cell id |
3 |
|
|
– Cell info |
Same content as specified for Intra-frequency cell id=3 in SIB11 for Cell 1 in clause 6.1.0b |
|
|
– Intra-frequency cell id |
7 |
|
|
– Cell info |
Same content as specified for Intra-frequency cell id=7 in SIB11 for Cell 1 in clause 6.1.0b |
|
|
– Intra-frequency cell id |
8 |
|
|
– Cell info |
Same content as specified for Intra-frequency cell id=8 in SIB11 for Cell 1 in clause 6.1.0b |
|
|
….. |
|
Condition |
Explanation |
|
A1 |
FDD cell environment |
|
A2 |
FDD/GSM inter-RAT cell environment |
|
A3 |
FDD intra-frequency cell environment (6 intra-frequency cells without inter-frequency cells) |
6.1.4.1 Default Cell parameters Two PLMN in UTRAN test scenario
In this scenario two cell groups belong to two different PLMN, Cell 1, 2, 3, 7, 8 (for PLMN1) and Cell 4,5,6 (for PLMN2) shall be configured on two different frequencies.
The contents of SYSTEM INFORMATION BLOCK TYPE 1 to 16 messages for cell No.1 to 8 are identical to those of cell No.1-8 in clause 6.1.4. Exceptions are found in SYSTEM INFORMATION BLOCK TYPE 11:
– SYSTEM INFORMATION BLOCK TYPE 11 for cell No.1, 2, 3, 7, 8 contains cell No.1, 2, 3, 7, 8 in Intra-frequency measurement system information, and cell No.4, 5, 6 in Inter-frequency measurement system information.
– SYSTEM INFORMATION BLOCK TYPE 11 for cell No.4,5,6 contains cell No.4,5,6 in Intra-frequency measurement system information, and cell No. 1, 2, 3, 7, 8 in Inter-frequency measurement system information.
– All other parameters in SYSTEM INFORMATION BLOCK TYPE 11 are set to identical to clause 6.1.4.
Contents of System Information Block type 18 for cell No.1, 2, 3, 7, 8
|
– Idle mode PLMN identities |
|
|
– PLMNs of intra-frequency cells list |
Not Present |
|
– PLMNs of inter-frequency cells list |
|
|
– PLMN identity |
Set to PLMN2 |
|
– PLMNs of inter-RAT cells list |
Not present |
|
– Connected mode PLMN identities |
Not present |
Contents of System Information Block type 18 for cell No.4, 5, 6
|
– Idle mode PLMN identities |
|
|
– PLMNs of intra-frequency cells list |
Not Present |
|
– PLMNs of inter-frequency cells list |
|
|
– PLMN identity |
Set to PLMN1 |
|
– PLMNs of inter-RAT cells list |
Not present |
|
– Connected mode PLMN identities |
Not present |
6.1.4.1a Default Cell parameters Two PLMN in UTRAN test scenario with cells on PLMN1 belonging to two different frequencies
In this scenario three cell groups belong to two different PLMN, Cell 1, 2, 3 (for PLMN1), Cell 4,5,6 (for PLMN1) and Cell 7,8 (for PLMN2) shall be configured on three different frequencies.
The contents of SYSTEM INFORMATION BLOCK TYPE 1 to 16 messages for cell No.1 to 8 are identical to those of cell No.1-8 in clause 6.1.4. Exceptions are found in SYSTEM INFORMATION BLOCK TYPE 11:
– SYSTEM INFORMATION BLOCK TYPE 11 for cell No.1, 2, 3 contains cell No.1, 2, 3 in Intra-frequency measurement system information, and cell No.4, 5, 6, 7, 8 in Inter-frequency measurement system information.
– SYSTEM INFORMATION BLOCK TYPE 11 for cell No.4, 5, 6 contains cell No. 4, 5, 6 in Intra-frequency measurement system information, and cell No. 1, 2, 3, 7, 8 in Inter-frequency measurement system information.
– SYSTEM INFORMATION BLOCK TYPE 11 for cell No. 7, 8 contains cell No. 7, 8 in Intra-frequency measurement system information, and cell No. 1, 2, 3, 4, 5, 6 in Inter-frequency measurement system information
– All other parameters in SYSTEM INFORMATION BLOCK TYPE 11 are set to identical to clause 6.1.4.
Contents of System Information Block type 18 for cell No.1, 2, 3, 4, 5, 6
|
– Idle mode PLMN identities |
|
|
– PLMNs of intra-frequency cells list |
Not Present |
|
– PLMNs of inter-frequency cells list |
|
|
– PLMN identity |
Set to PLMN1 |
|
– PLMN identity |
Set to PLMN1 |
|
– PLMN identity |
Set to PLMN1 |
|
– PLMN identity |
Set to PLMN2 |
|
– PLMNs of inter-RAT cells list |
Not present |
|
– Connected mode PLMN identities |
Not present |
Contents of System Information Block type 18 for cell No.7, 8
|
– Idle mode PLMN identities |
|
|
– PLMNs of intra-frequency cells list |
Not Present |
|
– PLMNs of inter-frequency cells list |
|
|
– PLMN identity |
Set to PLMN1 |
|
– PLMNs of inter-RAT cells list |
Not present |
|
– Connected mode PLMN identities |
Not present |
6.1.4.2 Default Cell parameters Three PLMN in UTRAN test scenario
In this scenario three cell groups belong to three different PLMN, Cell 1, 2, 3 (for PLMN1), Cell 4, 5, 6 (for PLMN2) and Cell 7, 8 (for PLMN3) shall be configured on three different frequencies.
The contents of SYSTEM INFORMATION BLOCK TYPE 1 to 16 messages for cell No.1 to 8 are identical to those of cell No.1-8 in clause 6.1.4. Exceptions are found in SYSTEM INFORMATION BLOCK TYPE 11:
– SYSTEM INFORMATION BLOCK TYPE 11 for cell No.1, 2, 3 contains cell No.1, 2, 3 in Intra-frequency measurement system information, and cell No.4, 5, 6, 7, 8 in Inter-frequency measurement system information.
– SYSTEM INFORMATION BLOCK TYPE 11 for cell No.4, 5, 6 contains cell No. 4, 5, 6 in Intra-frequency measurement system information, and cell No. 1, 2, 3, 7, 8 in Inter-frequency measurement system information.
– SYSTEM INFORMATION BLOCK TYPE 11 for cell No. 7, 8 contains cell No. 7, 8 in Intra-frequency measurement system information, and cell No. 1, 2, 3, 4, 5, 6 in Inter-frequency measurement system information.
– All other parameters in SYSTEM INFORMATION BLOCK TYPE 11 are set to identical to clause 6.1.4.
Contents of System Information Block type 18 for cell No.1, 2, 3
|
– Idle mode PLMN identities |
|
|
– PLMNs of intra-frequency cells list |
Not Present |
|
– PLMNs of inter-frequency cells list |
|
|
– PLMN identity |
Set to PLMN2 |
|
– PLMN identity |
Set to PLMN2 |
|
– PLMN identity |
Set to PLMN2 |
|
– PLMN identity |
Set to PLMN3 |
|
– PLMNs of inter-RAT cells list |
Not present |
|
– Connected mode PLMN identities |
Not present |
Contents of System Information Block type 18 for cell No.4, 5, 6
|
– Idle mode PLMN identities |
|
|
– PLMNs of intra-frequency cells list |
Not Present |
|
– PLMNs of inter-frequency cells list |
|
|
– PLMN identity |
Set to PLMN1 |
|
– PLMN identity |
Set to PLMN1 |
|
– PLMN identity |
Set to PLMN1 |
|
– PLMN identity |
Set to PLMN3 |
|
– PLMNs of inter-RAT cells list |
Not present |
|
– Connected mode PLMN identities |
Not present |
Contents of System Information Block type 18 for cell No.7, 8
|
– Idle mode PLMN identities |
|
|
– PLMNs of intra-frequency cells list |
Not Present |
|
– PLMNs of inter-frequency cells list |
|
|
– PLMN identity |
Set to PLMN1 |
|
– PLMN identity |
Set to PLMN1 |
|
– PLMN identity |
Set to PLMN1 |
|
– PLMN identity |
Set to PLMN2 |
|
– PLMNs of inter-RAT cells list |
Not present |
|
– Connected mode PLMN identities |
Not present |
6.1.4.3 Default Cell parameters for MBMS 21 to 28 cell environments
Cell No.21
The contents of SYSTEM INFORMATION BLOCK TYPE 1 to 16 messages for cell No.21 are identical to those of cell No.1 with the following exceptions.
|
Cell identity |
0000000000000000000000010101B |
|
URA identity |
0000 0000 0000 0001B |
Default settings for cell No.21 (FDD)
|
Downlink input level |
Reference clause 6.10 "Parameter Set" |
|
Uplink output power |
Minimum supported by the UE’s power class. |
|
PCCPCH/PCPICH carrier number |
Reference clause 6.10 "Parameter Set" |
|
Cell Channel Description |
|
|
– Primary CPICH info |
|
|
– Primary scrambling code |
120 |
Contents of System Information Block type 11 for cell No.21 (FDD)
|
– Intra-frequency measurement system information |
|
|
…. |
|
|
– New intra-frequency cells |
|
|
– Intra-frequency cell id |
21 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=1 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.21 (FDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
22 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.22 (FDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
23 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=3 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.23 (FDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
27 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=7 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.27 (FDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
28 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=8 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.28 (FDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
1 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.1 (FDD)" in clause 6.1.4 |
|
– Intra-frequency cell id |
2 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.2 (FDD)" in clause 6.1.4 |
|
– Intra-frequency cell id |
3 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=3 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.3 (FDD)" in clause 6.1.4 |
|
– Intra-frequency cell id |
7 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=7 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.7 (FDD)" in clause 6.1.4 |
|
– Intra-frequency cell id |
8 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=8 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.8 (FDD)" in clause 6.1.4 |
|
….. |
|
|
– Inter-frequency measurement system information |
|
|
….. |
|
|
– New inter-frequency cells |
|
|
– Inter frequency cell id |
24 |
|
– Frequency info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Cell info |
Same content as specified for Intra-frequency cell id=1 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.24 (FDD)" in clause 6.1.4 |
|
– Inter frequency cell id |
25 |
|
– Frequency info |
Not present Absence of this IE is equivalent to apply the default duplex distance defined for the operating frequency according to 25.101 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=5 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.25 (FDD)" in clause 6.1.4 |
|
– Inter frequency cell id |
26 |
|
– Frequency info |
Not present Absence of this IE is equivalent to apply the default duplex distance defined for the operating frequency according to 25.101 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=6 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.26 (FDD)" in clause 6.1.4 |
|
– Inter frequency cell id |
4 |
|
– Frequency info |
Not present Absence of this IE is equivalent to apply the default duplex distance defined for the operating frequency according to 25.101 |
|
– Cell info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Inter frequency cell id |
5 |
|
– Frequency info |
Not present Absence of this IE is equivalent to apply the default duplex distance defined for the operating frequency according to 25.101 |
|
– Cell info |
Same content as specified for Inter-frequency cell id=5 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Inter frequency cell id |
6 |
|
– Frequency info |
Not present Absence of this IE is equivalent to apply the default duplex distance defined for the operating frequency according to 25.101 |
|
– Cell info |
Same content as specified for Inter-frequency cell id=6 in SIB11 for Cell 1 in clause 6.1.0b |
|
….. |
Default settings for cell No.21 (TDD)
|
Downlink input level |
Reference clause 6 Parameter Set |
|
Uplink output power |
Minimum supported by the UE’s power class. |
|
PCCPCH/PCPICH carrier number |
Reference clause 6 Parameter Set |
|
Cell Channel Description |
|
|
– Primary CCPCH info |
|
|
– Cell parameters ID |
2 |
Contents of System Information Block type 11 for cell No.21 (TDD)
|
– Intra-frequency measurement system information |
|
|
…. |
|
|
– New intra-frequency cells |
|
|
– Intra-frequency cell id |
21 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=1 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.21 (TDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
22 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.22 (TDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
23 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=3 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.23 (TDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
27 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=7 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.27 (TDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
28 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=8 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.28 (TDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
1 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.1 (TDD)" in clause 6.1.4 |
|
– Intra-frequency cell id |
2 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Intra-frequency cell id |
3 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=3 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Intra-frequency cell id |
7 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=7 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Intra-frequency cell id |
8 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=8 in SIB11 for Cell 1 in clause 6.1.0b |
|
….. |
|
|
– Inter-frequency measurement system information |
|
|
….. |
|
|
– New inter-frequency cells |
|
|
– Inter frequency cell id |
24 |
|
– Frequency info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Cell info |
Same content as specified for Intra-frequency cell id=1 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.24 (TDD)" in clause 6.1.4.3 |
|
– Inter frequency cell id |
25 |
|
– Frequency info |
Not present |
|
– Cell info |
Same content as specified for Intra-frequency cell id=5 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.25 (TDD)" in clause 6.1.4.3 |
|
– Inter frequency cell id |
26 |
|
– Frequency info |
Not present |
|
– Cell info |
Same content as specified for Intra-frequency cell id=6 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.26 (TDD)" in clause 6.1.4.3 |
|
– Inter frequency cell id |
4 |
|
– Frequency info |
Not present |
|
– Cell info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Inter frequency cell id |
5 |
|
– Frequency info |
Not present |
|
– Cell info |
Same content as specified for Inter-frequency cell id=5 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Inter frequency cell id |
6 |
|
– Frequency info |
Not present |
|
– Cell info |
Same content as specified for Inter-frequency cell id=6 in SIB11 for Cell 1 in clause 6.1.0b |
|
….. |
Cell No.22
The contents of SYSTEM INFORMATION BLOCK TYPE 1 to 16 messages for cell No.22 are identical to those of cell No.1 with the following exceptions.
|
Cell identity |
0000000000000000000000010110B |
|
URA identity |
0000 0000 0000 0001B |
Default settings for cell No.22 (FDD)
|
Downlink input level |
Reference clause 6.10 "Parameter Set" |
|
Uplink output power |
Minimum supported by the UE’s power class. |
|
PCCPCH/PCPICH carrier number |
Reference clause 6.10 "Parameter Set" |
|
Cell Channel Description |
|
|
– Primary CPICH info |
|
|
– Primary scrambling code |
170 |
Contents of System Information Block type 11 for cell No.22 (FDD)
|
– Intra-frequency measurement system information |
|
|
…. |
|
|
– New intra-frequency cells |
|
|
– Intra-frequency cell id |
22 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=1 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.22 (FDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
21 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.21 (FDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
23 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=3 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.23 (FDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
27 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=7 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.27 (FDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
28 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=8 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.28 (FDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
2 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b |
|
– Intra-frequency cell id |
1 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.1 (FDD)" in clause 6.1.4 |
|
– Intra-frequency cell id |
3 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=3 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b |
|
– Intra-frequency cell id |
7 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=7 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b |
|
– Intra-frequency cell id |
8 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=8 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b |
|
….. |
|
|
– Inter-frequency measurement system information |
|
|
….. |
|
|
– New inter-frequency cells |
|
|
– Inter frequency cell id |
24 |
|
– Frequency info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Cell info |
Same content as specified for Intra-frequency cell id=1 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.24 (FDD)" in clause 6.1.4 |
|
– Inter frequency cell id |
25 |
|
– Frequency info |
Not present Absence of this IE is equivalent to apply the default duplex distance defined for the operating frequency according to 25.101 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=5 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.25 (FDD)" in clause 6.1.4 |
|
– Inter frequency cell id |
26 |
|
– Frequency info |
Not present Absence of this IE is equivalent to apply the default duplex distance defined for the operating frequency according to 25.101 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=6 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.26 (FDD)" in clause 6.1.4 |
|
– Inter frequency cell id |
4 |
|
– Frequency info |
Not present Absence of this IE is equivalent to apply the default duplex distance defined for the operating frequency according to 25.101 |
|
– Cell info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Inter frequency cell id |
5 |
|
– Frequency info |
Not present Absence of this IE is equivalent to apply the default duplex distance defined for the operating frequency according to 25.101 |
|
– Cell info |
Same content as specified for Inter-frequency cell id=5 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Inter frequency cell id |
6 |
|
– Frequency info |
Not present Absence of this IE is equivalent to apply the default duplex distance defined for the operating frequency according to 25.101 |
|
– Cell info |
Same content as specified for Inter-frequency cell id=6 in SIB11 for Cell 1 in clause 6.1.0b |
|
….. |
Default settings for cell No.22 (TDD)
|
Downlink input level |
Reference clause 6 Parameter Set |
|
Uplink output power |
Minimum supported by the UE’s power class. |
|
PCCPCH/PCPICH carrier number |
Reference clause 6 Parameter Set |
|
Cell Channel Description |
|
|
– Primary CCPCH info |
|
|
– Cell parameters ID |
6 |
Contents of System Information Block type 11 for cell No.22 (TDD)
|
– Intra-frequency measurement system information |
|
|
…. |
|
|
– New intra-frequency cells |
|
|
– Intra-frequency cell id |
22 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=1 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.22 (TDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
21 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.21 (TDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
23 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=3 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.23 (TDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
27 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=7 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.27 (TDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
28 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=8 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.28 (TDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
1 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.1 (TDD)" in clause 6.1.4 |
|
– Intra-frequency cell id |
2 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Intra-frequency cell id |
3 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=3 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Intra-frequency cell id |
7 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=7 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Intra-frequency cell id |
8 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=8 in SIB11 for Cell 1 in clause 6.1.0b |
|
….. |
|
|
– Inter-frequency measurement system information |
|
|
….. |
|
|
– New inter-frequency cells |
|
|
– Inter frequency cell id |
24 |
|
– Frequency info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Cell info |
Same content as specified for Intra-frequency cell id=1 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.24 (TDD)" in clause 6.1.4.3 |
|
– Inter frequency cell id |
25 |
|
– Frequency info |
Not present |
|
– Cell info |
Same content as specified for Intra-frequency cell id=5 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.25 (TDD)" in clause 6.1.4.3 |
|
– Inter frequency cell id |
26 |
|
– Frequency info |
Not present |
|
– Cell info |
Same content as specified for Intra-frequency cell id=6 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.26 (TDD)" in clause 6.1.4.3 |
|
– Inter frequency cell id |
4 |
|
– Frequency info |
Not present |
|
– Cell info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Inter frequency cell id |
5 |
|
– Frequency info |
Not present |
|
– Cell info |
Same content as specified for Inter-frequency cell id=5 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Inter frequency cell id |
6 |
|
– Frequency info |
Not present |
|
– Cell info |
Same content as specified for Inter-frequency cell id=6 in SIB11 for Cell 1 in clause 6.1.0b |
|
….. |
Cell No.23
The contents of SYSTEM INFORMATION BLOCK TYPE 1 to 16 messages for cell No.23 are identical to those of cell No.1 with the following exceptions.
|
Cell identity |
0000000000000000000000010111B |
|
URA identity |
0000 0000 0000 0010B |
Default settings for cell No.23 (FDD)
|
Downlink input level |
Reference clause 6.10 "Parameter Set" |
|
Uplink output power |
Minimum supported by the UE’s power class. |
|
PCCPCH/PCPICH carrier number |
Reference clause 6.10 "Parameter Set" |
|
Cell Channel Description |
|
|
– Primary CPICH info |
|
|
– Primary scrambling code |
220 |
Contents of System Information Block type 11 for cell No.23 (FDD)
|
– Intra-frequency measurement system information |
|
|
…. |
|
|
– New intra-frequency cells |
|
|
– Intra-frequency cell id |
23 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=1 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.23 (FDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
21 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.21 (FDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
22 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.22 (FDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
27 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=7 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.27 (FDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
28 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=8 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.28 (FDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
3 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=3 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b |
|
– Intra-frequency cell id |
1 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.1 (FDD)" in clause 6.1.4 |
|
– Intra-frequency cell id |
2 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b |
|
– Intra-frequency cell id |
7 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=7 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b |
|
– Intra-frequency cell id |
8 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=8 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b |
|
….. |
|
|
– Inter-frequency measurement system information |
|
|
….. |
|
|
– New inter-frequency cells |
|
|
– Inter frequency cell id |
24 |
|
– Frequency info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Cell info |
Same content as specified for Intra-frequency cell id=4 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.24 (FDD)" in clause 6.1.4 |
|
– Inter frequency cell id |
25 |
|
– Frequency info |
Not present Absence of this IE is equivalent to apply the default duplex distance defined for the operating frequency according to 25.101 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=5 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.25 (FDD)" in clause 6.1.4 |
|
– Inter frequency cell id |
26 |
|
– Frequency info |
Not present Absence of this IE is equivalent to apply the default duplex distance defined for the operating frequency according to 25.101 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=6 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.26 (FDD)" in clause 6.1.4 |
|
– Inter frequency cell id |
4 |
|
– Frequency info |
Not present Absence of this IE is equivalent to apply the default duplex distance defined for the operating frequency according to 25.101 |
|
– Cell info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Inter frequency cell id |
5 |
|
– Frequency info |
Not present Absence of this IE is equivalent to apply the default duplex distance defined for the operating frequency according to 25.101 |
|
– Cell info |
Same content as specified for Inter-frequency cell id=5 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Inter frequency cell id |
6 |
|
– Frequency info |
Not present Absence of this IE is equivalent to apply the default duplex distance defined for the operating frequency according to 25.101 |
|
– Cell info |
Same content as specified for Inter-frequency cell id=6 in SIB11 for Cell 1 in clause 6.1.0b |
|
….. |
Default settings for cell No.23 (TDD)
|
Downlink input level |
Reference clause 6 Parameter Set |
|
Uplink output power |
Minimum supported by the UE’s power class. |
|
PCCPCH/PCPICH carrier number |
Reference clause 6 Parameter Set |
|
Cell Channel Description |
|
|
– Primary CCPCH info |
|
|
– Cell parameters ID |
10 |
Contents of System Information Block type 11 for cell No.23 (TDD)
|
– Intra-frequency measurement system information |
|
|
…. |
|
|
– New intra-frequency cells |
|
|
– Intra-frequency cell id |
23 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=1 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.23 (TDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
21 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.21 (TDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
22 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.22 (TDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
27 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=7 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.27 (TDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
28 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=8 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.28 (TDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
1 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.1 (TDD)" in clause 6.1.4 |
|
– Intra-frequency cell id |
2 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Intra-frequency cell id |
3 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=3 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Intra-frequency cell id |
7 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=7 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Intra-frequency cell id |
8 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=8 in SIB11 for Cell 1 in clause 6.1.0b |
|
….. |
|
|
– Inter-frequency measurement system information |
|
|
….. |
|
|
– New inter-frequency cells |
|
|
– Inter frequency cell id |
24 |
|
– Frequency info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Cell info |
Same content as specified for Intra-frequency cell id=1 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.24 (TDD)" in clause 6.1.4.3 |
|
– Inter frequency cell id |
25 |
|
– Frequency info |
Not present |
|
– Cell info |
Same content as specified for Intra-frequency cell id=5 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.25 (TDD)" in clause 6.1.4.3 |
|
– Inter frequency cell id |
26 |
|
– Frequency info |
Not present |
|
– Cell info |
Same content as specified for Intra-frequency cell id=6 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.26 (TDD)" in clause 6.1.4.3 |
|
– Inter frequency cell id |
4 |
|
– Frequency info |
Not present |
|
– Cell info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Inter frequency cell id |
5 |
|
– Frequency info |
Not present |
|
– Cell info |
Same content as specified for Inter-frequency cell id=5 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Inter frequency cell id |
6 |
|
– Frequency info |
Not present |
|
– Cell info |
Same content as specified for Inter-frequency cell id=6 in SIB11 for Cell 1 in clause 6.1.0b |
|
….. |
Cell No.24
The contents of SYSTEM INFORMATION BLOCK TYPE 1 to 16 messages for cell No.24 are identical to those of cell No.1 with the following exceptions.
|
Cell identity |
0000000000000000000000011000B |
|
URA identity |
0000 0000 0000 0010B |
Default settings for cell No.24 (FDD)
|
Downlink input level |
Reference clause 6.10 "Parameter Set" |
|
Uplink output power |
Minimum supported by the UE’s power class. |
|
PCCPCH/PCPICH carrier number |
Reference clause 6.10 "Parameter Set" |
|
Cell Channel Description |
|
|
– Primary CPICH info |
|
|
– Primary scrambling code |
270 |
Contents of System Information Block type 11 for cell No.24 (FDD)
|
– Intra-frequency measurement system information |
|
|
…. |
|
|
– New intra-frequency cells |
|
|
– Intra-frequency cell id |
24 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=1 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.24 (FDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
25 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.25 (FDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
26 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.26 (FDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
4 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.4 (FDD)" in clause 6.1.4 |
|
– Intra-frequency cell id |
5 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.5 (FDD)" in clause 6.1.4 |
|
– Intra-frequency cell id |
6 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.6 (FDD)" in clause 6.1.4 |
|
….. |
|
|
– Inter-frequency measurement system information |
|
|
….. |
|
|
– New inter-frequency cells |
|
|
– Inter frequency cell id |
21 |
|
– Frequency info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Cell info |
Same content as specified for Intra-frequency cell id=4 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.21 (FDD)" in clause 6.1.4 |
|
– Inter frequency cell id |
22 |
|
– Frequency info |
Not present Absence of this IE is equivalent to apply the default duplex distance defined for the operating frequency according to 25.101 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=4 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.22 (FDD)" in clause 6.1.4 |
|
– Inter frequency cell id |
23 |
|
– Frequency info |
Not present Absence of this IE is equivalent to apply the default duplex distance defined for the operating frequency according to 25.101 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=4 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.23 (FDD)" in clause 6.1.4 |
|
– Inter frequency cell id |
27 |
|
– Frequency info |
Not present Absence of this IE is equivalent to apply the default duplex distance defined for the operating frequency according to 25.101 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=4 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.23 (FDD)" in clause 6.1.4 |
|
– Inter frequency cell id |
28 |
|
– Frequency info |
Not present Absence of this IE is equivalent to apply the default duplex distance defined for the operating frequency according to 25.101 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=4 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.23 (FDD)" in clause 6.1.4 |
|
– Inter frequency cell id |
1 |
|
– Frequency info |
Not present Absence of this IE is equivalent to apply the default duplex distance defined for the operating frequency according to 25.101 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=4 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.23 (FDD)" in clause 6.1.4 |
|
– Inter frequency cell id |
2 |
|
– Frequency info |
Not present Absence of this IE is equivalent to apply the default duplex distance defined for the operating frequency according to 25.101 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=4 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.23 (FDD)" in clause 6.1.4 |
|
– Inter frequency cell id |
3 |
|
– Frequency info |
Not present Absence of this IE is equivalent to apply the default duplex distance defined for the operating frequency according to 25.101 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=4 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.23 (FDD)" in clause 6.1.4 |
|
– Inter frequency cell id |
7 |
|
– Frequency info |
Not present Absence of this IE is equivalent to apply the default duplex distance defined for the operating frequency according to 25.101 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=4 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.23 (FDD)" in clause 6.1.4 |
|
– Inter frequency cell id |
8 |
|
– Frequency info |
Not present Absence of this IE is equivalent to apply the default duplex distance defined for the operating frequency according to 25.101 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=4 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.23 (FDD)" in clause 6.1.4 |
|
.. |
Default settings for cell No.24 (TDD)
|
Downlink input level |
Reference clause 6 Parameter Set |
|
Uplink output power |
Minimum supported by the UE’s power class. |
|
PCCPCH/PCPICH carrier number |
Reference clause 6 Parameter Set |
|
Cell Channel Description |
|
|
– Primary CCPCH info |
|
|
– Cell parameters ID |
14 |
Contents of System Information Block type 11 for cell No.24 (TDD)
|
– Intra-frequency measurement system information |
|
|
…. |
|
|
– New intra-frequency cells |
|
|
– Intra-frequency cell id |
24 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=1 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.24 (TDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
25 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.25 (TDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
26 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.26 (TDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
4 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.4 (TDD)" in clause 6.1.4 |
|
– Intra-frequency cell id |
5 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.5 (TDD)" in clause 6.1.4 |
|
– Intra-frequency cell id |
6 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.6 (TDD)" in clause 6.1.4 |
|
….. |
|
|
– Inter-frequency measurement system information |
|
|
….. |
|
|
– New inter-frequency cells |
|
|
– Inter frequency cell id |
21 |
|
– Frequency info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Cell info |
Same content as specified for Intra-frequency cell id=1 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.21 (TDD)" in clause 6.1.4.3 |
|
– Inter frequency cell id |
22 |
|
– Frequency info |
Not present |
|
– Cell info |
Same content as specified for Intra-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.22 (TDD)" in clause 6.1.4.3 |
|
– Inter frequency cell id |
23 |
|
– Frequency info |
Not present |
|
– Cell info |
Same content as specified for Intra-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.23 (TDD)" in clause 6.1.4.3 |
|
– Inter frequency cell id |
27 |
|
– Frequency info |
Not present |
|
– Cell info |
Same content as specified for Intra-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.27 (TDD)" in clause 6.1.4.3 |
|
– Inter frequency cell id |
28 |
|
– Frequency info |
Not present |
|
– Cell info |
Same content as specified for Intra-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.28 (TDD)" in clause 6.1.4.3 |
|
– Inter frequency cell id |
1 |
|
– Frequency info |
Not present |
|
– Cell info |
Same content as specified for Intra-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.1 (TDD)" in clause 6.1.4 |
|
– Inter frequency cell id |
2 |
|
– Frequency info |
Not present |
|
– Cell info |
Same content as specified for Intra-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.2 (TDD)" in clause 6.1.4 |
|
– Inter frequency cell id |
3 |
|
– Frequency info |
Not present |
|
– Cell info |
Same content as specified for Intra-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.3 (TDD)" in clause 6.1.4 |
|
– Inter frequency cell id |
7 |
|
– Frequency info |
Not present |
|
– Cell info |
Same content as specified for Intra-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.7 (TDD)" in clause 6.1.4 |
|
– Inter frequency cell id |
8 |
|
– Frequency info |
Not present |
|
– Cell info |
Same content as specified for Intra-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.8 (TDD)" in clause 6.1.4 |
|
….. |
Cell No.25
The contents of SYSTEM INFORMATION BLOCK TYPE 1 to 16 messages for cell No.25 are identical to those of cell No.4 with the following exceptions.
|
Cell identity |
0000 0000 0000 0000 0000 0001 1001B |
|
URA identity |
0000 0000 0000 0011B |
Default settings for cell No.25 (FDD)
|
Downlink input level |
Reference clause 6.10 "Parameter Set" |
|
Uplink output power |
Minimum supported by the UE’s power class. |
|
PCCPCH/PCPICH carrier number |
Reference clause 6.10 "Parameter Set" |
|
Cell Channel Description |
|
|
– Primary CPICH info |
|
|
– Primary scrambling code |
320 |
Contents of System Information Block type 11 for cell No.25 (FDD)
|
– Intra-frequency measurement system information |
|
|
…. |
|
|
– New intra-frequency cells |
|
|
– Intra-frequency cell id |
25 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=1 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.25 (FDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
24 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.24 (FDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
26 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.26 (FDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
5 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.5 (FDD)" in clause 6.1.4 |
|
– Intra-frequency cell id |
4 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.4 (FDD)" in clause 6.1.4 |
|
– Intra-frequency cell id |
6 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.6 (FDD)" in clause 6.1.4 |
|
….. |
|
|
– Inter-frequency measurement system information |
|
|
….. |
|
|
– New inter-frequency cells |
|
|
– Inter frequency cell id |
21 |
|
– Frequency info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Cell info |
Same content as specified for Intra-frequency cell id=1 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.21 (FDD)" in clause 6.1.4 |
|
– Inter frequency cell id |
22 |
|
– Frequency info |
Not present Absence of this IE is equivalent to apply the default duplex distance defined for the operating frequency according to 25.101 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=4 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.22 (FDD)" in clause 6.1.4 |
|
– Inter frequency cell id |
23 |
|
– Frequency info |
Not present Absence of this IE is equivalent to apply the default duplex distance defined for the operating frequency according to 25.101 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=4 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.23 (FDD)" in clause 6.1.4 |
|
– Inter frequency cell id |
27 |
|
– Frequency info |
Not present Absence of this IE is equivalent to apply the default duplex distance defined for the operating frequency according to 25.101 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=4 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.23 (FDD)" in clause 6.1.4 |
|
– Inter frequency cell id |
28 |
|
– Frequency info |
Not present Absence of this IE is equivalent to apply the default duplex distance defined for the operating frequency according to 25.101 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=4 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.23 (FDD)" in clause 6.1.4 |
|
– Inter frequency cell id |
1 |
|
– Frequency info |
Not present Absence of this IE is equivalent to apply the default duplex distance defined for the operating frequency according to 25.101 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=4 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.23 (FDD)" in clause 6.1.4 |
|
– Inter frequency cell id |
2 |
|
– Frequency info |
Not present Absence of this IE is equivalent to apply the default duplex distance defined for the operating frequency according to 25.101 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=4 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.23 (FDD)" in clause 6.1.4 |
|
– Inter frequency cell id |
3 |
|
– Frequency info |
Not present Absence of this IE is equivalent to apply the default duplex distance defined for the operating frequency according to 25.101 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=4 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.23 (FDD)" in clause 6.1.4 |
|
– Inter frequency cell id |
7 |
|
– Frequency info |
Not present Absence of this IE is equivalent to apply the default duplex distance defined for the operating frequency according to 25.101 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=4 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.23 (FDD)" in clause 6.1.4 |
|
– Inter frequency cell id |
8 |
|
– Frequency info |
Not present Absence of this IE is equivalent to apply the default duplex distance defined for the operating frequency according to 25.101 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=4 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.23 (FDD)" in clause 6.1.4 |
|
.. |
Default settings for cell No.25 (TDD)
|
Downlink input level |
Reference clause 6 Parameter Set |
|
Uplink output power |
Minimum supported by the UE’s power class. |
|
PCCPCH/PCPICH carrier number |
Reference clause 6 Parameter Set |
|
Cell Channel Description |
|
|
– Primary CCPCH info |
|
|
– Cell parameters ID |
116 |
Contents of System Information Block type 11 for cell No.25 (TDD)
|
– Intra-frequency measurement system information |
|
|
…. |
|
|
– New intra-frequency cells |
|
|
– Intra-frequency cell id |
25 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=1 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.25 (TDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
24 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.24 (TDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
26 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.26 (TDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
4 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.4 (TDD)" in clause 6.1.4 |
|
– Intra-frequency cell id |
5 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.5 (TDD)" in clause 6.1.4 |
|
– Intra-frequency cell id |
6 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.6 (TDD)" in clause 6.1.4 |
|
….. |
|
|
– Inter-frequency measurement system information |
|
|
….. |
|
|
– New inter-frequency cells |
|
|
– Inter frequency cell id |
21 |
|
– Frequency info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Cell info |
Same content as specified for Intra-frequency cell id=1 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.21 (TDD)" in clause 6.1.4.3 |
|
– Inter frequency cell id |
22 |
|
– Frequency info |
Not present |
|
– Cell info |
Same content as specified for Intra-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.22 (TDD)" in clause 6.1.4.3 |
|
– Inter frequency cell id |
23 |
|
– Frequency info |
Not present |
|
– Cell info |
Same content as specified for Intra-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.23 (TDD)" in clause 6.1.4.3 |
|
– Inter frequency cell id |
27 |
|
– Frequency info |
Not present |
|
– Cell info |
Same content as specified for Intra-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.27 (TDD)" in clause 6.1.4.3 |
|
– Inter frequency cell id |
28 |
|
– Frequency info |
Not present |
|
– Cell info |
Same content as specified for Intra-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.28 (TDD)" in clause 6.1.4.3 |
|
– Inter frequency cell id |
1 |
|
– Frequency info |
Not present |
|
– Cell info |
Same content as specified for Intra-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.1 (TDD)" in clause 6.1.4 |
|
– Inter frequency cell id |
2 |
|
– Frequency info |
Not present |
|
– Cell info |
Same content as specified for Intra-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.2 (TDD)" in clause 6.1.4 |
|
– Inter frequency cell id |
3 |
|
– Frequency info |
Not present |
|
– Cell info |
Same content as specified for Intra-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.3 (TDD)" in clause 6.1.4 |
|
– Inter frequency cell id |
7 |
|
– Frequency info |
Not present |
|
– Cell info |
Same content as specified for Intra-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.7 (TDD)" in clause 6.1.4 |
|
– Inter frequency cell id |
8 |
|
– Frequency info |
Not present |
|
– Cell info |
Same content as specified for Intra-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.8 (TDD)" in clause 6.1.4 |
|
….. |
Cell No.26
The contents of SYSTEM INFORMATION BLOCK TYPE 1 to 16 messages for cell No.26 are identical to those of cell No.4 with the following exceptions:
|
Cell identity |
0000 0000 0000 0000 0000 0001 1010B |
|
URA identity |
0000 0000 0000 0011B |
Default settings for cell No.26 (FDD)
|
Downlink input level |
Reference clause 6 Parameter Set |
|
Uplink output power |
Minimum supported by the UE’s power class. |
|
PCCPCH/PCPICH carrier number |
Reference clause 6 Parameter Set |
|
Cell Channel Description |
|
|
– Primary CPICH info |
|
|
– Primary scrambling code |
370 |
Contents of System Information Block type 11 for cell No.26 (FDD)
|
– Intra-frequency measurement system information |
|
|
…. |
|
|
– New intra-frequency cells |
|
|
– Intra-frequency cell id |
26 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=1 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.26 (FDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
24 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.24 (FDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
25 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.25 (FDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
6 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.6 (FDD)" in clause 6.1.4 |
|
– Intra-frequency cell id |
4 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.4 (FDD)" in clause 6.1.4 |
|
– Intra-frequency cell id |
5 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.5 (FDD)" in clause 6.1.4 |
|
….. |
|
|
– Inter-frequency measurement system information |
|
|
….. |
|
|
– New inter-frequency cells |
|
|
– Inter frequency cell id |
21 |
|
– Frequency info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Cell info |
Same content as specified for Intra-frequency cell id=4 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.21 (FDD)" in clause 6.1.4 |
|
– Inter frequency cell id |
22 |
|
– Frequency info |
Not present Absence of this IE is equivalent to apply the default duplex distance defined for the operating frequency according to 25.101 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=4 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.22 (FDD)" in clause 6.1.4 |
|
– Inter frequency cell id |
23 |
|
– Frequency info |
Not present Absence of this IE is equivalent to apply the default duplex distance defined for the operating frequency according to 25.101 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=4 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.23 (FDD)" in clause 6.1.4 |
|
– Inter frequency cell id |
27 |
|
– Frequency info |
Not present Absence of this IE is equivalent to apply the default duplex distance defined for the operating frequency according to 25.101 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=4 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.23 (FDD)" in clause 6.1.4 |
|
– Inter frequency cell id |
28 |
|
– Frequency info |
Not present Absence of this IE is equivalent to apply the default duplex distance defined for the operating frequency according to 25.101 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=4 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.23 (FDD)" in clause 6.1.4 |
|
– Inter frequency cell id |
1 |
|
– Frequency info |
Not present Absence of this IE is equivalent to apply the default duplex distance defined for the operating frequency according to 25.101 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=4 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.23 (FDD)" in clause 6.1.4 |
|
– Inter frequency cell id |
2 |
|
– Frequency info |
Not present Absence of this IE is equivalent to apply the default duplex distance defined for the operating frequency according to 25.101 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=4 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.23 (FDD)" in clause 6.1.4 |
|
– Inter frequency cell id |
3 |
|
– Frequency info |
Not present Absence of this IE is equivalent to apply the default duplex distance defined for the operating frequency according to 25.101 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=4 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.23 (FDD)" in clause 6.1.4 |
|
– Inter frequency cell id |
7 |
|
– Frequency info |
Not present Absence of this IE is equivalent to apply the default duplex distance defined for the operating frequency according to 25.101 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=4 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.23 (FDD)" in clause 6.1.4 |
|
– Inter frequency cell id |
8 |
|
– Frequency info |
Not present Absence of this IE is equivalent to apply the default duplex distance defined for the operating frequency according to 25.101 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=4 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.23 (FDD)" in clause 6.1.4 |
|
.. |
Default settings for cell No.26 (TDD)
|
Downlink input level |
Reference clause 6 Parameter Set |
|
Uplink output power |
Minimum supported by the UE’s power class. |
|
PCCPCH/PCPICH carrier number |
Reference clause 6 Parameter Set |
|
Cell Channel Description |
|
|
– Primary CCPCH info |
|
|
– Cell parameters ID |
121 |
Contents of System Information Block type 11 for cell No.26 (TDD)
|
– Intra-frequency measurement system information |
|
|
…. |
|
|
– New intra-frequency cells |
|
|
– Intra-frequency cell id |
26 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=1 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.25 (TDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
24 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.24 (TDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
25 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.26 (TDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
4 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.4 (TDD)" in clause 6.1.4 |
|
– Intra-frequency cell id |
5 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.5 (TDD)" in clause 6.1.4 |
|
– Intra-frequency cell id |
6 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.6 (TDD)" in clause 6.1.4 |
|
….. |
|
|
– Inter-frequency measurement system information |
|
|
….. |
|
|
– New inter-frequency cells |
|
|
– Inter frequency cell id |
21 |
|
– Frequency info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Cell info |
Same content as specified for Intra-frequency cell id=1 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.21 (TDD)" in clause 6.1.4.3 |
|
– Inter frequency cell id |
22 |
|
– Frequency info |
Not present |
|
– Cell info |
Same content as specified for Intra-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.22 (TDD)" in clause 6.1.4.3 |
|
– Inter frequency cell id |
23 |
|
– Frequency info |
Not present |
|
– Cell info |
Same content as specified for Intra-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.23 (TDD)" in clause 6.1.4.3 |
|
– Inter frequency cell id |
27 |
|
– Frequency info |
Not present |
|
– Cell info |
Same content as specified for Intra-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.27 (TDD)" in clause 6.1.4.3 |
|
– Inter frequency cell id |
28 |
|
– Frequency info |
Not present |
|
– Cell info |
Same content as specified for Intra-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.28 (TDD)" in clause 6.1.4.3 |
|
– Inter frequency cell id |
1 |
|
– Frequency info |
Not present |
|
– Cell info |
Same content as specified for Intra-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.1 (TDD)" in clause 6.1.4 |
|
– Inter frequency cell id |
2 |
|
– Frequency info |
Not present |
|
– Cell info |
Same content as specified for Intra-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.2 (TDD)" in clause 6.1.4 |
|
– Inter frequency cell id |
3 |
|
– Frequency info |
Not present |
|
– Cell info |
Same content as specified for Intra-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.3 (TDD)" in clause 6.1.4 |
|
– Inter frequency cell id |
7 |
|
– Frequency info |
Not present |
|
– Cell info |
Same content as specified for Intra-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.7 (TDD)" in clause 6.1.4 |
|
– Inter frequency cell id |
8 |
|
– Frequency info |
Not present |
|
– Cell info |
Same content as specified for Intra-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.8 (TDD)" in clause 6.1.4 |
|
….. |
Cell No.27
The contents of SYSTEM INFORMATION BLOCK TYPE 1 to 16 messages for cell No.27 are identical to those of cell No.1 with the following exceptions.
|
Cell identity |
0000 0000 0000 0000 0000 0001 1011B |
|
URA identity |
0000 0000 0000 0100B |
Default settings for cell No.27 (FDD)
|
Downlink input level |
Reference clause 6.10 "Parameter Set" |
|
Uplink output power |
Minimum supported by the UE’s power class. |
|
PCCPCH/PCPICH carrier number |
Reference clause 6.10 "Parameter Set" |
|
Cell Channel Description |
|
|
– Primary CPICH info |
|
|
– Primary scrambling code |
420 |
Contents of System Information Block type 11 for cell No.27 (FDD)
|
– Intra-frequency measurement system information |
|
|
…. |
|
|
– New intra-frequency cells |
|
|
– Intra-frequency cell id |
27 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=1 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.27 (FDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
21 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.21 (FDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
22 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.22 (FDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
23 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=3 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.23 (FDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
28 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=8 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.28 (FDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
7 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.7 (FDD)" in clause 6.1.4 |
|
– Intra-frequency cell id |
1 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.1 (FDD)" in clause 6.1.4 |
|
– Intra-frequency cell id |
2 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.2 (FDD)" in clause 6.1.4 |
|
– Intra-frequency cell id |
3 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=3 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.3 (FDD)" in clause 6.1.4 |
|
– Intra-frequency cell id |
8 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=8 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.8 (FDD)" in clause 6.1.4 |
|
….. |
|
|
– Inter-frequency measurement system information |
|
|
….. |
|
|
– New inter-frequency cells |
|
|
– Inter frequency cell id |
24 |
|
– Frequency info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Cell info |
Same content as specified for Intra-frequency cell id=1 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.24 (FDD)" in clause 6.1.4 |
|
– Inter frequency cell id |
25 |
|
– Frequency info |
Not present Absence of this IE is equivalent to apply the default duplex distance defined for the operating frequency according to 25.101 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=5 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.25 (FDD)" in clause 6.1.4 |
|
– Inter frequency cell id |
26 |
|
– Frequency info |
Not present Absence of this IE is equivalent to apply the default duplex distance defined for the operating frequency according to 25.101 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=6 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.26 (FDD)" in clause 6.1.4 |
|
– Inter frequency cell id |
4 |
|
– Frequency info |
Not present Absence of this IE is equivalent to apply the default duplex distance defined for the operating frequency according to 25.101 |
|
– Cell info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Inter frequency cell id |
5 |
|
– Frequency info |
Not present Absence of this IE is equivalent to apply the default duplex distance defined for the operating frequency according to 25.101 |
|
– Cell info |
Same content as specified for Inter-frequency cell id=5 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Inter frequency cell id |
6 |
|
– Frequency info |
Not present Absence of this IE is equivalent to apply the default duplex distance defined for the operating frequency according to 25.101 |
|
– Cell info |
Same content as specified for Inter-frequency cell id=6 in SIB11 for Cell 1 in clause 6.1.0b |
|
….. |
Default settings for cell No.27 (TDD)
|
Downlink input level |
Reference clause 6 Parameter Set |
|
Uplink output power |
Minimum supported by the UE’s power class. |
|
PCCPCH/PCPICH carrier number |
Reference clause 6 Parameter Set |
|
Cell Channel Description |
|
|
– Primary CCPCH info |
|
|
– Cell parameters ID |
125 |
Contents of System Information Block type 11 for cell No.27 (TDD)
|
– Intra-frequency measurement system information |
|
|
…. |
|
|
– New intra-frequency cells |
|
|
– Intra-frequency cell id |
27 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=1 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.27 (TDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
21 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.21 (TDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
22 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.22 (TDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
23 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=3 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.23 (TDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
28 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=8 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.28 (TDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
1 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.1 (TDD)" in clause 6.1.4 |
|
– Intra-frequency cell id |
2 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Intra-frequency cell id |
3 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=3 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Intra-frequency cell id |
7 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=7 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Intra-frequency cell id |
8 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=8 in SIB11 for Cell 1 in clause 6.1.0b |
|
….. |
|
|
– Inter-frequency measurement system information |
|
|
….. |
|
|
– New inter-frequency cells |
|
|
– Inter frequency cell id |
24 |
|
– Frequency info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Cell info |
Same content as specified for Intra-frequency cell id=1 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.24 (TDD)" in clause 6.1.4.3 |
|
– Inter frequency cell id |
25 |
|
– Frequency info |
Not present |
|
– Cell info |
Same content as specified for Intra-frequency cell id=5 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.25 (TDD)" in clause 6.1.4.3 |
|
– Inter frequency cell id |
26 |
|
– Frequency info |
Not present |
|
– Cell info |
Same content as specified for Intra-frequency cell id=6 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.26 (TDD)" in clause 6.1.4.3 |
|
– Inter frequency cell id |
4 |
|
– Frequency info |
Not present |
|
– Cell info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Inter frequency cell id |
5 |
|
– Frequency info |
Not present |
|
– Cell info |
Same content as specified for Inter-frequency cell id=5 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Inter frequency cell id |
6 |
|
– Frequency info |
Not present |
|
– Cell info |
Same content as specified for Inter-frequency cell id=6 in SIB11 for Cell 1 in clause 6.1.0b |
|
….. |
Cell No.28
The contents of SYSTEM INFORMATION BLOCK TYPE 1 to 16 messages for cell No.28 are identical to those of cell No.1 with the following exceptions:
|
Cell identity |
0000 0000 0000 0000 0000 0001 1000B |
|
URA identity |
0000 0000 0000 0100B |
Default settings for cell No.28 (FDD)
|
Downlink input level |
Reference clause 6.10 "Parameter Set" |
|
Uplink output power |
Minimum supported by the UE’s power class. |
|
PCCPCH/PCPICH carrier number |
Reference clause 6.10 "Parameter Set" |
|
Cell Channel Description |
|
|
– Primary CPICH info |
|
|
– Primary scrambling code |
470 |
Contents of System Information Block type 11 for cell No.28 (FDD)
|
– Intra-frequency measurement system information |
|
|
…. |
|
|
– New intra-frequency cells |
|
|
– Intra-frequency cell id |
28 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=1 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.28 (FDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
21 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.21 (FDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
22 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.22 (FDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
23 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=3 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.23 (FDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
27 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=7 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.27 (FDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
8 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.8 (FDD)" in clause 6.1.4 |
|
– Intra-frequency cell id |
1 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.1 (FDD)" in clause 6.1.4 |
|
– Intra-frequency cell id |
2 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.2 (FDD)" in clause 6.1.4 |
|
– Intra-frequency cell id |
3 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=3 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.3 (FDD)" in clause 6.1.4 |
|
– Intra-frequency cell id |
7 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=7 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.7 (FDD)" in clause 6.1.4 |
|
….. |
|
|
– Inter-frequency measurement system information |
|
|
….. |
|
|
– New inter-frequency cells |
|
|
– Inter frequency cell id |
24 |
|
– Frequency info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Cell info |
Same content as specified for Intra-frequency cell id=1 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.24 (FDD)" in clause 6.1.4 |
|
– Inter frequency cell id |
25 |
|
– Frequency info |
Not present Absence of this IE is equivalent to apply the default duplex distance defined for the operating frequency according to 25.101 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=5 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.25 (FDD)" in clause 6.1.4 |
|
– Inter frequency cell id |
26 |
|
– Frequency info |
Not present Absence of this IE is equivalent to apply the default duplex distance defined for the operating frequency according to 25.101 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=6 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.26 (FDD)" in clause 6.1.4 |
|
– Inter frequency cell id |
4 |
|
– Frequency info |
Not present Absence of this IE is equivalent to apply the default duplex distance defined for the operating frequency according to 25.101 |
|
– Cell info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Inter frequency cell id |
5 |
|
– Frequency info |
Not present Absence of this IE is equivalent to apply the default duplex distance defined for the operating frequency according to 25.101 |
|
– Cell info |
Same content as specified for Inter-frequency cell id=5 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Inter frequency cell id |
6 |
|
– Frequency info |
Not present Absence of this IE is equivalent to apply the default duplex distance defined for the operating frequency according to 25.101 |
|
– Cell info |
Same content as specified for Inter-frequency cell id=6 in SIB11 for Cell 1 in clause 6.1.0b |
|
….. |
Default settings for cell No.28 (TDD)
|
Downlink input level |
Reference clause 6 Parameter Set |
|
Uplink output power |
Minimum supported by the UE’s power class. |
|
PCCPCH/PCPICH carrier number |
Reference clause 6 Parameter Set |
|
Cell Channel Description |
|
|
– Primary CCPCH info |
|
|
– Cell parameters ID |
129 |
Contents of System Information Block type 11 for cell No.28 (TDD)
|
– Intra-frequency measurement system information |
|
|
…. |
|
|
– New intra-frequency cells |
|
|
– Intra-frequency cell id |
28 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=1 (serving cell) in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.28 (TDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
21 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.21 (TDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
22 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.22 (TDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
23 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=3 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.23 (TDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
27 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=7 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.27(TDD)" in clause 6.1.4.3 |
|
– Intra-frequency cell id |
1 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.1 (TDD)" in clause 6.1.4 |
|
– Intra-frequency cell id |
2 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=2 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Intra-frequency cell id |
3 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=3 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Intra-frequency cell id |
7 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=7 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Intra-frequency cell id |
8 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=8 in SIB11 for Cell 1 in clause 6.1.0b |
|
….. |
|
|
– Inter-frequency measurement system information |
|
|
….. |
|
|
– New inter-frequency cells |
|
|
– Inter frequency cell id |
24 |
|
– Frequency info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Cell info |
Same content as specified for Intra-frequency cell id=1 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.24 (TDD)" in clause 6.1.4.3 |
|
– Inter frequency cell id |
25 |
|
– Frequency info |
Not present |
|
– Cell info |
Same content as specified for Intra-frequency cell id=5 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.25 (TDD)" in clause 6.1.4.3 |
|
– Inter frequency cell id |
26 |
|
– Frequency info |
Not present |
|
– Cell info |
Same content as specified for Intra-frequency cell id=6 in SIB11 for Cell 1 in clause 6.1.0b with the exception that value for Primary scrambling code shall be according to clause titled "Default settings for cell No.26 (TDD)" in clause 6.1.4.3 |
|
– Inter frequency cell id |
4 |
|
– Frequency info |
Not present |
|
– Cell info |
Same content as specified for Inter-frequency cell id=4 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Inter frequency cell id |
5 |
|
– Frequency info |
Not present |
|
– Cell info |
Same content as specified for Inter-frequency cell id=5 in SIB11 for Cell 1 in clause 6.1.0b |
|
– Inter frequency cell id |
6 |
|
– Frequency info |
Not present |
|
– Cell info |
Same content as specified for Inter-frequency cell id=6 in SIB11 for Cell 1 in clause 6.1.0b |
|
….. |
6.1.4.4 Default Cell parameters for MBSFN 31 to 38 cell environments
Cell No.31
Default settings for cell No.31 (TDD)
|
Downlink input level |
Reference clause 6.1.6 |
|
PCCPCH/PCPICH carrier number |
Reference clause 5.1.2 |
|
Cell Channel Description |
|
|
– Primary CCPCH info |
|
|
– Cell parameters ID |
1 |
Default settings for cell No.31 (3.84 Mcps TDD IMB)
|
Downlink input level |
Reference clause 6.1.6.1 " Reference Radio Conditions (3.84 Mcps TDD IMB)" |
|
PCCPCH/PCPICH carrier number |
Reference clause 5.1.2 |
|
Cell Channel Description |
|
|
– Primary CPICH info |
|
|
– Primary scrambling code |
128 |
Default settings for cell No.31 (FDD)
|
Downlink input level |
Reference clause 6.10 "Parameter Set" |
|
Uplink output power |
Minimum supported by the UE’s power class. |
|
PCCPCH/PCPICH carrier number |
Reference clause 6.10 "Parameter Set" |
|
Cell Channel Description |
|
|
– Primary CPICH info |
|
|
– Primary scrambling code |
120 |
Contents of System Information Block type 3 for cell No.31 (FDD, TDD)
|
Information Element |
Value/remark |
Version |
|
– SIB4 Indicator |
FALSE |
|
|
– Cell identity |
0000 0000 0000 0000 0000 0001 1111B |
|
|
– Cell selection and re-selection info |
||
|
– Mapping info |
Not present |
|
|
– Cell selection and reselection quality measure |
CPICH RSCP |
|
|
– CHOICE mode |
TDD |
|
|
– Sintrasearch |
Not present |
|
|
– Sintersearch |
Not present |
|
|
– SsearchHCS |
Not present |
|
|
– RAT List |
Not present |
|
|
– Qrxlevmin |
-103 (dBm) |
|
|
– DeltaQrxlevmin |
Not Present |
|
|
– Qhyst1s |
1 (dB = value*2 (step size)) |
|
|
– Qhyst1s,PCH |
Not Present |
|
|
– Qhyst1s,FACH |
Not Present |
|
|
– Qhyst2s |
Not Present |
|
|
– Qhyst2s,PCH |
Not Present |
|
|
– Qhyst2s,FACH |
Not Present |
|
|
– Treselections |
1 (second) |
|
|
– Treselections,PCH |
Not Present |
|
|
– Treselections,FACH |
Not Present |
|
|
– Speed dependent ScalingFactor for Treselection |
Not Present |
|
|
– Inter-frequency ScalingFactor for Treselection |
Not Present |
|
|
– Inter-RAT ScalingFactor for Treselection |
Not Present |
|
|
– Non-HCS_TCRmax |
Not Present (MD, default = ‘not used’) |
|
|
– Non-HCS_NCR |
Not Present (MD) |
|
|
– Non-HCS_TCRmaxHyst |
Not Present |
|
|
– HCS Serving cell information |
Not present |
|
|
– Maximum allowed UL TX power |
1 (dBm) |
|
|
– Cell Access Restriction |
||
|
– Cell barred |
barred |
|
|
– Intra-frequency cell re-selection indicator |
not allowed |
|
|
– Tbarred |
1280 |
|
|
– Cell Reserved for operator use |
not reserved |
|
|
– Cell Reservation Extension |
not reserved |
|
|
– Access Class Barred List |
Not Present (MD – no access class barred) |
|
|
– Domain Specific Access Restriction Parameters For PLMN Of MIB |
Not Present |
REL-6 |
|
– Domain Specific Access Restriction For Shared Network |
Not Present |
REL-6 |
|
– Deferred measurement control UTRAN support |
Not Present |
REL-7 |
|
– MBSFN only service |
true |
REL-7 |
Contents of System Information Block type 3 for cell No.31 (3.84 Mcps TDD IMB)
|
Information Element |
Value/remark |
Version |
|
-SIB4 Indicator |
FALSE |
|
|
-Cell identity |
0000 0000 0000 0000 0000 0001 1111B |
|
|
-Cell selection and re-selection info |
||
|
-Mapping Info |
Not present |
|
|
-Cell selection and reselection quality measure |
CPICH RSCP |
|
|
-choice mode |
FDD |
|
|
-Sintrasearch |
Not present |
|
|
-Sintersearch |
Not present |
|
|
-SsearchHCS |
Not present |
|
|
-RAT List |
Not present |
|
|
-Qqualmin |
Reference to Table 6.1.6.1 |
|
|
-Qrxlevmin |
Reference to Table 6.1.6.1 |
|
|
-DeltaQrxlevmin |
Not present |
|
|
-Qhyst1s |
1 (2 dB) |
|
|
-Qhyst2s |
Not present |
|
|
-Treselections |
1 seconds |
|
|
-Speed dependent ScalingFactor for Treselection |
Not present |
REL-5 |
|
-Inter-frequency ScalingFactor for Treselection |
Not present |
REL-5 |
|
-Inter-RAT ScalingFactor for Treselection |
Not present |
REL-5 |
|
-Non-HCS_TCRmax |
Not used |
REL-5 |
|
-HCS Serving cell Information |
Not present |
REL-5 |
|
-Maximum allowed UL TX power |
1(dBm) |
|
|
-Cell Access Restriction |
||
|
-Cell Barred |
barred |
|
|
-Intra-frequency cell re-selection indicator |
Not-allowed |
|
|
-Tbarred |
1280 |
|
|
-Cell Reserved for operator use |
Not reserved |
|
|
-Cell Reservation Extension |
Not reserved |
|
|
-Access Class Barred list |
Not present (MD- no access class barred) |
|
|
-Domain Specific Access Restriction Parameters For PLMN Of MIB |
Not present |
REL-6 |
|
-Domain Specific Access Restriction For Shared Network |
Not present |
|
|
-Deferred measurement control reading |
Not present |
REL-6 |
|
-MBSFN only service |
TRUE |
REL-7 |
|
-Paging Permission with Access Control Parameters For PLMN Of MIB |
Not present |
REL-8 |
|
-Paging Permission with Access Control For Shared Network |
Not present |
REL-8 |
|
-CSG Identity |
Not present |
REL-8 |
|
-CSG PSC Split Information |
Not present |
REL-8 |
Contents of System Information Block type 5 for cell No.31 (FDD)
FFS
Contents of System Information Block type 5 for cell No.31 (3.84 Mcps TDD)
|
– SIB6 indicator |
FALSE |
|
– PICH Power offset |
0 dB |
|
– CHOICE Mode |
TDD |
|
– PUSCH system information |
Not Present |
|
– PUSCH system information VHCR |
Not Present |
|
– PDSCH system information |
Not Present |
|
– TDD open loop power control |
|
|
– Primary CCPCH Tx Power |
30 dbm |
|
– CHOICE TDD option |
3.84 Mcps TDD |
|
– Alpha |
Not present |
|
– PRACH Constant Value |
-10 |
|
– DPCH Constant Value |
-10 |
|
– PUSCH Constant Value |
Not present |
|
– UE positioning related parameters |
Not Present |
|
– Primary CCPCH info |
Not Present |
|
– PRACH system information list |
|
|
– PRACH system information |
|
|
– PRACH info |
|
|
– CHOICE mode |
TDD |
|
– CHOICE TDD option |
3.84 Mcps TDD |
|
– Timeslot number |
14 |
|
– PRACH Channelisation Code List |
|
|
– CHOICE SF |
SF8 |
|
– Channelisation Code List |
|
|
– Channelisation Code |
8/1 |
|
– PRACH Midamble |
Direct |
|
– PNBSCH allocation |
Not Present |
|
– Transport channel Identity |
15 |
|
– RACH TFS |
|
|
– CHOICE Transport channel type |
Common transport channels |
|
– Dynamic Transport format information |
|
|
– RLC size |
16 |
|
– Number of TBs and TTI List |
|
|
– Number of Transport blocks |
0 |
|
– CHOICE mode |
TDD |
|
– Transmission Time Interval |
Not Present |
|
– CHOICE Logical channel List |
ALL |
|
– Semi-static Transport Format information |
|
|
– Transmission time interval |
10 |
|
– Type of channel coding |
No coding |
|
– Coding Rate |
Not Present |
|
– Rate matching attribute |
1 |
|
– CRC size |
0 |
|
– Additional RACH TFS for CCCH |
Not present |
|
– RACH TFCS |
Not present |
|
– Additional RACH TFCS for CCCH |
Not present |
|
– PRACH partitioning |
|
|
– Access Service Class |
|
|
– ASC Settings |
Not Present (Default all) |
|
– Persistence scaling factors |
Not Present |
|
– AC-to-ASC mapping |
|
|
– AC-to-ASC mapping table |
|
|
– AC-to-ASC mapping |
6 (AC0-9) |
|
– AC-to-ASC mapping |
5 (AC10) |
|
– AC-to-ASC mapping |
4 (AC11) |
|
– AC-to-ASC mapping |
3 (AC12) |
|
– AC-to-ASC mapping |
2 (AC13) |
|
– AC-to-ASC mapping |
1 (AC14) |
|
– AC-to-ASC mapping |
0 (AC15) |
|
– CHOICE mode |
TDD (no data) |
|
– Secondary CCPCH system information |
(MP – but treated as if not received by UE) |
|
– Secondary CCPCH system information list |
(MP – but treated as if not received by UE) |
|
– Secondary CCPCH info |
|
|
– CHOICE mode |
3.84 Mcps TDD |
|
– Offset |
0 |
|
– Common timeslot info |
|
|
– 2nd interleaving mode |
Not Present (MD "Frame") |
|
– TFCI coding |
Not Present (MD) |
|
– Puncturing limit |
1.0 |
|
– Repetition period |
Not Present (MD "1") |
|
– Repetition length |
Not present (empty) |
|
– Individual timeslot info |
|
|
– CHOICE TDD option |
3.84 Mcps TDD |
|
– Timeslot number |
1 |
|
– TFCI existence |
FALSE |
|
– Midamble Shift and burst type |
|
|
– CHOICE TDD option |
3.84 Mcps TDD |
|
– CHOICE Burst Type |
MBSFN Burst Type |
|
– no data |
|
|
– CHOICE TDD option |
3.84 Mcps TDD |
|
– no data |
|
|
– Code List |
|
|
– Channelisation Code |
16/1 |
|
– TFCS |
(MP – but treated as if not received by UE) |
|
-CHOICE TFCI signalling |
Normal TFCI signalling |
|
– TFCI Field 1 information |
|
|
– CHOICE TFCS representation |
Complete reconfiguration |
|
– TFCS complete reconfiguration information |
|
|
– CHOICE CTFC Size |
2 bit CTFC |
|
– CTFC information |
|
|
– 2 bit CTFC |
0 |
|
– Power offset information |
Not Present |
|
– FACH/PCH information list |
(MP – but treated as if not received by UE) |
|
– TFS |
|
|
– CHOICE Transport channel type |
Common transport channels |
|
– Dynamic Transport format information |
|
|
– RLC Size |
16 |
|
– Number of TBs and TTI List |
|
|
– Number of Transport blocks |
0 |
|
– CHOICE mode |
TDD |
|
– Transmission Time Interval |
10 |
|
– CHOICE Logical Channel List |
ALL |
|
– Semi-static Transport Format information |
|
|
– Transmission time interval |
10 |
|
– Type of channel coding |
No coding |
|
– Coding Rate |
Not Present |
|
– Rate matching attribute |
1 |
|
– CRC size |
0 |
|
– Transport channel Identity |
1 |
|
– CTCH indicator |
FALSE |
|
– PICH info |
Not Present |
|
– MCCH configuration information |
Not Present |
|
– CBS DRX Level 1 information |
Not Present |
|
– Frequency band indicator |
Not Present |
|
– Frequency band indicator 2 |
Not Present |
|
– HSDPA cell Indicator |
Not Present (Default ‘HSDPA capability not indicated’) |
|
– E-DCH cell Indicator |
Not Present (Default ‘E-DCH capability not indicated’) |
|
– Secondary CCPCH system information MBMS |
|
|
– Secondary CCPCH system information |
|
|
– Secondary CCPCH info MBMS |
|
|
– CHOICE mode |
3.84 Mcps TDD |
|
– Common timeslot info MBMS |
|
|
– 2nd interleaving mode |
Frame |
|
– TFCI coding |
Reference clause 6.10 "Parameter Set" |
|
– Puncturing limit |
Reference clause 6.10 "Parameter Set" |
|
– Downlink Timeslots and Codes |
|
|
– First Individual timeslot info |
|
|
– Timeslot number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD |
|
– Timeslot number |
0 |
|
– TFCI existence |
Reference clause 6.10 "Parameter Set" |
|
– Midamble Shift and burst type |
|
|
– CHOICE TDD option |
3.84 Mcps TDD |
|
– CHOICE Burst Type |
MBSFN Burst Type |
|
– no data |
|
|
– CHOICE TDD option |
3.84 Mcps TDD |
|
– no data |
|
|
– First timeslot channelisation codes |
|
|
– CHOICE codes representation |
Reference clause 5.5.2 "Downlink physical channels code allocation for Signalling" |
|
– CHOICE more timeslots |
No more timeslots |
|
– no data |
|
|
– Modulation |
QPSK |
|
– TFCS |
|
|
– CHOICE TFCI signalling |
Normal TFCI signalling |
|
– TFCI Field 1 information |
|
|
– CHOICE TFCS representation |
Complete reconfiguration |
|
– TFCS complete reconfiguration information |
|
|
– CHOICE CTFC Size |
2 bit |
|
– CTFC information |
|
|
– 2bit CTFC |
0 |
|
– Power offset information |
Not Present |
|
– CTFC information |
|
|
– 2bit CTFC |
1 |
|
– Power offset information |
Not Present |
|
– CTFC information |
|
|
– 2bit CTFC |
2 |
|
– Power offset information |
Not Present |
|
– CTFC information |
|
|
– 2bit CTFC |
3 |
|
– Power offset information |
Not Present |
|
– FACH carrying MCCH |
|
|
– TFS |
|
|
– CHOICE Transport channel type |
Common transport channels |
|
– Dynamic Transport Format Information |
|
|
– RLC Size |
Reference clause 6.10 "Parameter Set" |
|
– Number of TBs and TTI List |
Reference clause 6.10 "Parameter Set" |
|
– Number of Transport blocks |
Reference clause 6.10 "Parameter Set" |
|
– CHOICE mode |
TDD |
|
– Transmission Time Interval |
Not Present |
|
– CHOICE Logical Channel List |
ALL |
|
– no data |
|
|
– Semi-static Transport Format information |
|
|
– Transmission time interval |
Reference clause 6.10 "Parameter Set" |
|
– Type of channel coding |
Turbo |
|
– Coding Rate |
Not Present |
|
– Rate matching attribute |
Reference clause 6.10 "Parameter Set" |
|
– CRC size |
Reference clause 6.10 "Parameter Set" |
|
– MCCH configuration information |
|
|
– Access Info Period coefficient |
Reference clause 11.1.1 "MCCH configuration parameters" |
|
– Repetition Period coefficient |
Reference clause 11.1.1 "MCCH configuration parameters" |
|
– Modification period coefficient |
Reference clause 11.1.1 "MCCH configuration parameters" |
|
– RLC info |
|
|
– DL UM RLC LI size |
7 |
|
– DL Duplication Avoidance and Reordering info |
Not Present |
|
– DL Out of sequence delivery info |
|
|
– Timer_OSD |
Not Present |
|
– Window size OSD |
48 |
|
– TCTF presence |
false |
|
– FACH carrying MTCH list |
Not Present |
|
– Scheduling information |
Not Present |
|
– CHOICE mode |
TDD |
|
– no data |
|
|
– TDD MBSFN information |
|
|
– Time slot list |
(This list describes all Timeslots (0…14) in the frame) |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD |
|
– Timeslot number |
0 |
|
– Cell parameters ID |
1 |
|
– Timeslot Number |
(Repeated for each Timeslot (1…14) |
|
– CHOICE TDD option |
3.84 Mcps TDD |
|
– Timeslot number |
(1…14) |
|
– Cell parameters ID |
5 (Repeated for each Timeslot (1…14) |
Contents of System Information Block type 5 for cell No.31 (3.84 Mcps TDD IMB)
|
Information Element |
Value/remark |
Version |
|
– SIB6 indicator |
FALSE |
|
|
– PICH Power offset |
-5 dB (MP-but treated as if not received by UE) |
|
|
– CHOICE Mode |
FDD |
|
|
– AICH Power offset |
-5 dB (MP-but treated as if not received by UE) |
|
|
– Primary CCPCH info |
Not present |
|
|
– PRACH system information list |
(MP-but treated as if not received by UE) |
|
|
– PRACH system information |
|
|
|
– PRACH info |
|
|
|
– CHOICE mode |
FDD |
|
|
– Available Signature |
‘0000 0000 1111 1111’B |
|
|
– Available SF |
64 |
|
|
– Preamble scrambling code number |
0 |
|
|
– Puncturing Limit |
1.00 |
|
|
– Available Sub Channel number |
‘1111 1111 1111’B |
|
|
– Transport channel Identity |
15 |
|
|
– RACH TFS |
|
|
|
– CHOICE Transport channel type |
Common transport channels |
|
|
– Dynamic Transport format information |
|
|
|
– RLC size |
168 |
|
|
– Number of TB and TTI List |
|
|
|
– Number of Transport blocks |
1 |
|
|
– CHOICE Mode |
FDD |
|
|
– CHOICE Logical channel List |
ALL |
|
|
– Semi-static Transport Format information |
|
|
|
– Transmission time interval |
20 ms |
|
|
– Type of channel coding |
Turbo |
|
|
– Rate matching attribute |
150 |
|
|
– CRC size |
16 |
|
|
– Additional RACH TFS for CCCH |
Not present |
Rel6 |
|
– RACH TFCS |
|
|
|
– CHOICE TFCI signalling |
Normal |
|
|
– TFCI Field 1 information |
|
|
|
– CHOICE TFCS representation |
Complete reconfiguration |
|
|
– TFCS complete reconfiguration information |
|
|
|
– CHOICE CTFC Size |
2 bit CTFC |
|
|
– CTFC information |
0 |
|
|
– 2bit CTFC |
0 |
|
|
– Power offset information |
Not present |
|
|
– CTFC information |
1 |
|
|
– 2bit CTFC |
1 |
|
|
– Power offset information |
Not present |
|
|
– CTFC information |
2 |
|
|
– 2bit CTFC |
2 |
|
|
– Power offset information |
Not present |
|
|
– CTFC information |
3 |
|
|
– 2bit CTFC |
3 |
|
|
– Power offset information |
Not present |
|
|
– Additional RACH TFCS for CCCH |
Not present |
Rel-6 |
|
– PRACH partitioning |
|
|
|
– Access Service Class |
|
|
|
– ASC Setting |
|
|
|
– CHOICE mode |
FDD |
|
|
– Available signature Start Index |
0 (ASC#1) |
|
|
– Available signature End Index |
7 (ASC#1) |
|
|
– Assigned Sub-Channel Number |
‘1111’B |
|
|
The first/ leftmost bit of the bit string contains the most significant bit of the Assigned Sub-Channel Number. |
||
|
– ASC Setting |
|
|
|
– CHOICE mode |
FDD |
|
|
– Available signature Start Index |
0 (ASC#3) |
|
|
– Available signature End Index |
7 (ASC#3) |
|
|
– Assigned Sub-Channel Number |
‘1111’B |
|
|
The first/ leftmost bit of the bit string contains the most significant bit of the Assigned Sub-Channel Number. |
||
|
– ASC Setting |
|
|
|
– CHOICE mode |
FDD |
|
|
– Available signature Start Index |
0 (ASC#5) |
|
|
– Available signature End Index |
7 (ASC#5) |
|
|
– Assigned Sub-Channel Number |
‘1111’B |
|
|
The first/ leftmost bit of the bit string contains the most significant bit of the Assigned Sub-Channel Number. |
||
|
– ASC Setting |
|
|
|
– CHOICE mode |
FDD |
|
|
– Available signature Start Index |
0 (ASC#7) |
|
|
– Available signature End Index |
7 (ASC#7) |
|
|
– Assigned Sub-Channel Number |
‘1111’B |
|
|
The first/ leftmost bit of the bit string contains the most significant bit of the Assigned Sub-Channel Number. |
||
|
– Persistence scaling factor |
Not present |
|
|
– AC-to-ASC mapping table |
|
|
|
– AC-to-ASC mapping |
6 (AC0-9) |
|
|
– AC-to-ASC mapping |
5 (AC10) |
|
|
– AC-to-ASC mapping |
4 (AC11) |
|
|
– AC-to-ASC mapping |
3 (AC12) |
|
|
– AC-to-ASC mapping |
2 (AC13) |
|
|
– AC-to-ASC mapping |
1 (AC14) |
|
|
– AC-to-ASC mapping |
0 (AC15) |
|
|
– CHOICE mode |
FDD |
|
|
– Primary CPICH TX power |
31 |
|
|
– Constant value |
-10 |
|
|
– PRACH power offset |
|
|
|
– Power Ramp Step |
3dB |
|
|
– Preamble Retrans Max |
4 |
|
|
– RACH transmission parameters |
|
|
|
– Mmax |
2 |
|
|
– NB01min |
3 slot |
|
|
– NB01max |
10 slot |
|
|
– AICH info |
|
|
|
– Channelisation code |
3 |
|
|
– STTD indicator |
FALSE |
|
|
– AICH transmission timing |
0 |
|
|
Common E-DCH system info |
Not present |
|
|
Secondary CCPCH system information |
(MP-but treated as if not received by UE) |
|
|
Secondary CCPCH system information list |
|
|
|
– Secondary CCPCH info |
|
|
|
– CHOICE mode |
FDD |
|
|
– Secondary scrambling code |
Not Present |
|
|
– STTD indicator |
FALSE |
|
|
– Spreading factor |
64 |
|
|
– Code number |
1 |
|
|
– Pilot symbol existence |
FALSE |
|
|
– TFCI existence |
TRUE (default value) |
|
|
– Fixed or Flexible position |
Flexible (default value) |
|
|
– Timing offset |
Not Present |
|
|
Absence of this IE is equivalent to default value 0 |
||
|
– TFCS |
(This IE is repeated for TFC number for PCH and FACH.) |
|
|
– CHOICE TFCI signalling |
Normal |
|
|
– TFCI Field 1 information |
|
|
|
– CHOICE TFCS representation |
Complete reconfiguration |
|
|
– TFCS complete reconfiguration information |
|
|
|
– CHOICE CTFC Size |
2 bit CTFC |
|
|
– CTFC information |
0 |
|
|
-2 bit CTFC |
0 |
|
|
– Power offset information |
Not Present |
|
|
– CTFC information |
1 |
|
|
-2 bit CTFC |
1 |
|
|
– Power offset information |
Not Present |
|
|
– CTFC information |
2 |
|
|
-2 bit CTFC |
2 |
|
|
– Power offset information |
Not Present |
|
|
– CTFC information |
3 |
|
|
-2 bit CTFC |
3 |
|
|
– Power offset information |
Not Present |
|
|
– FACH/PCH information |
|
|
|
– TFS |
(FACH) |
|
|
– CHOICE Transport channel type |
Common transport channels |
|
|
– Dynamic Transport format information |
|
|
|
– RLC Size |
168 |
|
|
– Number of TB and TTI List |
|
|
|
– Number of Transport blocks |
0 |
|
|
– Number of Transport blocks |
1 |
|
|
– Number of Transport blocks |
2 |
|
|
– CHOICE Logical channel List |
ALL |
|
|
– Semi-static Transport Format information |
|
|
|
– Transmission time interval |
10 ms |
|
|
– Type of channel coding |
Convolutional |
|
|
– Coding Rate |
1/2 |
|
|
– Rate matching attribute |
220 |
|
|
– CRC size |
16 bit |
|
|
– Transport channel Identity |
13 (for FACH) |
|
|
– CTCH indicator |
FALSE |
|
|
– PICH info |
Not Present |
|
|
– MCCH configuration information |
Not Present |
Rel-6 |
|
– CBS DRX Level 1 information |
Not Present |
|
|
– Frequency Band Indicator |
Not Present |
|
|
– Frequency Band Indicator 2 |
Not Present |
|
|
HSDPA cell Indicator |
Not Present (MD- default is “HSDPA capability not indicated”) |
|
|
E-DCH cell Indicator |
Not Present (MD- default is “E-DCH capability not indicated”) |
|
|
– Secondary CCPCH system information MBMS |
|
Rel-6 |
|
– Secondary CCPCH info MBMS |
|
|
|
– CHOICE Mode |
3.84 Mcps TDD MBSFN IMB |
Rel-8 |
|
– Secondary scrambling code |
Not Present |
Rel-8 |
|
– STTD indicator |
FALSE |
Rel-8 |
|
– Spreading factor |
256 |
Rel-8 |
|
– Code number |
2 |
Rel-8 |
|
– Timing Offset |
Not present (MD) |
Rel-8 |
|
– CHOICE Modulation |
QPSK |
Rel-8 |
|
– TFCS |
|
|
|
– CHOICE TFCI signalling |
Normal |
|
|
– TFCI Field 1 information |
|
|
|
– CHOICE TFCS representation |
Complete reconfiguration |
|
|
– TFCS complete reconfiguration information |
|
|
|
– CHOICE CTFC Size |
2 bit CTFC |
|
|
– CTFC information |
0 |
|
|
– 2 bit CTFC |
0 |
|
|
– Power offset information |
Not Present |
|
|
– CTFC information |
1 |
|
|
– 2 bit CTFC |
1 |
|
|
– Power offset information |
Not Present |
|
|
– CTFC information |
2 |
|
|
– 2 bit CTFC |
2 |
|
|
– Power offset information |
Not Present |
|
|
– CTFC information |
3 |
|
|
– 2 bit CTFC |
3 |
|
|
– Power offset information |
Not Present |
|
|
– FACH carrying MCCH |
|
|
|
– TFS |
|
|
|
– CHOICE Transport channel type |
Common transport channels |
|
|
– Dynamic Transport format information |
|
|
|
– RLC Size |
Reference clause 6.11.7 " Reference Radio Bearer configurations used in Radio Bearer testing for 3.84 Mcps TDD IMB" |
|
|
– Number of TB and TTI List |
Reference clause 6.11.7 " Reference Radio Bearer configurations used in Radio Bearer testing for 3.84 Mcps TDD IMB" |
|
|
– Number of Transport blocks |
Reference clause 6.11.7 " Reference Radio Bearer configurations used in Radio Bearer testing for 3.84 Mcps TDD IMB" |
|
|
– Number of Transport blocks |
remove |
|
|
– CHOICE Logical channel List |
ALL |
|
|
– no data |
|
|
|
– Semi-static Transport Format information |
|
|
|
– Transmission time interval |
Reference clause 6.11.7 " Reference Radio Bearer configurations used in Radio Bearer testing for 3.84 Mcps TDD IMB" |
|
|
– Type of channel coding |
turbo |
|
|
– Coding Rate |
not present |
|
|
– Rate matching attribute |
Reference clause 6.11.7 " Reference Radio Bearer configurations used in Radio Bearer testing for 3.84 Mcps TDD IMB" |
|
|
– CRC size |
Reference clause 6.11.7 " Reference Radio Bearer configurations used in Radio Bearer testing for 3.84 Mcps TDD IMB" |
|
|
– MCCH configuration information |
|
|
|
– Access Info Period coefficient |
Reference to clause 11.2.1 “MCCH configuration parameters” |
|
|
– Repetition Period coefficient |
Reference to clause 11.2.1 “MCCH configuration parameters” |
|
|
– Modification period coefficient |
Reference to clause 11.2.1 “MCCH configuration parameters” |
|
|
– RLC info MBMS |
|
|
|
– DL UM RLC LI size |
7 |
|
|
– DL Duplication Avoidance and Reordering info |
Not Present |
|
|
– DL Out of sequence delivery info |
|
|
|
– Timer_OSD |
Not Present |
|
|
– Window size OSD |
48 |
|
|
– TCTF presence |
FALSE |
|
|
– FACH carrying MTCH list |
Not Present |
|
|
– Scheduling information |
Not Present |
|
|
– CHOICE Mode |
FDD |
Rel-7 |
|
– HS-DSCH common system information |
(MP-but treated as if not received by UE) |
Rel-7 |
|
– CCCH mapping info |
|
|
|
– Logical channel identity |
5 |
|
|
– MAC-ehs queue identity |
1 |
|
|
– SRB1 mapping info |
Not Present |
|
|
– Common MAC-ehs reordering queue list |
|
|
|
– MAC-ehs queue to configure list |
Configure 2 queues |
|
|
– MAC-ehs queue Id |
0 |
|
|
– T1 |
50ms |
|
|
– Treset |
Not Present |
|
|
– MAC-ehs window size |
16 |
|
|
– MAC-ehs queue Id |
1 |
|
|
– T1 |
50ms |
|
|
– Treset |
Not Present |
|
|
– MAC-ehs window size |
16 |
|
|
– HS-SCCH system info |
|
|
|
– DL Scrambling Code |
Not Present |
|
|
– HS-SCCH Channelisation Code Information |
Use 1 HS-SCCH |
|
|
– HS-SCCH Channelisation Code |
7 |
|
|
– HARQ system Info |
|
|
|
– Number of Processes |
1 |
|
|
– CHOICE Memory Partitioning |
Implicit |
|
|
– Common H-RNTI Information |
Use 4 |
|
|
– Common H-RNTI |
‘1111 1010 1010 1010’ |
|
|
– Common H-RNTI |
‘1111 1010 1010 1011’ |
|
|
– Common H-RNTI |
‘1111 1010 1010 1100’ |
|
|
– Common H-RNTI |
‘1111 1010 1010 1110’ |
|
|
– BCCH specific H-RNTI |
‘1111 1010 1110 1010’ |
|
|
– HS-DSCH paging system information |
Not Present |
Rel-7 |
|
TDD MBSFN information |
not present |
Rel-7 |
|
HS-DSCH DRX in CELL_FACH Information |
not present |
Rel-8 |
|
HS-DSCH DRX in CELL_FACH Information 1.28 Mcps TDD |
not present |
Rel-8 |
|
|
|
|
Contents of System Information Block type 5 for cell No.31 (1.28 Mcps TDD)
|
– SIB6 indicator |
FALSE |
|
– PICH Power offset |
0 dB |
|
– CHOICE Mode |
TDD |
|
– PUSCH system information |
Not Present |
|
– PUSCH system information VHCR |
Not Present |
|
– PDSCH system information |
Not Present |
|
– TDD open loop power control |
(MP – but treated as if not received by UE) |
|
– Primary CCPCH Tx Power |
30 dbm |
|
– CHOICE TDD option |
1.28 Mcps TDD |
|
– Primary CCPCH info |
Not Present |
|
– PRACH system information list |
(MP – but treated as if not received by UE) |
|
– PRACH system information |
|
|
– PRACH info |
|
|
– CHOICE mode |
TDD |
|
– CHOICE TDD option |
1.28 Mcps TDD |
|
– SYNC_UL info |
|
|
– SYNC_UL codes bitmap |
"11111111" |
|
– UL Target SIR |
10 dB |
|
– Power Ramping Ste p |
3 dB |
|
– Max SYNC_UL Transmissions |
8 |
|
– Mmax |
32 |
|
– PRACH definition |
|
|
– Timeslot number |
|
|
– CHOICE TDD option |
1.28 Mcps TDD |
|
– Timeslot number |
1 |
|
– PRACH Channelisation Code |
|
|
– Channelisation Code List |
|
|
– Channelisation Code |
(8/1) |
|
– Midamble Shift and burst type |
|
|
– CHOICE TDD option |
1.28 Mcps TDD |
|
– Midamble Allocation Mode |
Default midamble |
|
– Midamble configuration |
8 |
|
– Midamble Shift |
Not present |
|
– FPACH info |
|
|
– Timeslot number |
6 |
|
– Channelisation code |
(16/16) |
|
– Midamble Shift and burst type |
|
|
– CHOICE TDD option |
1.28 Mcps TDD |
|
– Midamble Allocation Mode |
Common Midamble |
|
– Midamble configuration |
8 |
|
– Midamble Shift |
Not present |
|
– WT |
4 |
|
– Transport channel Identity |
15 |
|
– RACH TFS |
|
|
– CHOICE Transport channel type |
Common transport channels |
|
– Dynamic Transport format information |
|
|
– RLC size |
16 |
|
– Number of TBs and TTI List |
|
|
– Number of Transport blocks |
0 |
|
– CHOICE mode |
TDD |
|
– Transmission Time Interval |
Not Present |
|
– CHOICE Logical channel List |
ALL |
|
– Semi-static Transport Format information |
|
|
– Transmission time interval |
10 |
|
– Type of channel coding |
No coding |
|
– Coding Rate |
Not Present |
|
– Rate matching attribute |
1 |
|
– CRC size |
0 |
|
– Additional RACH TFS for CCCH |
Not present |
|
– RACH TFCS |
Not present |
|
– Additional RACH TFCS for CCCH |
Not present |
|
– PRACH partitioning |
|
|
– Access Service Class |
|
|
– ASC Settings |
Not Present (Default all) |
|
– Persistence scaling factors |
Not Present |
|
– AC-to-ASC mapping |
|
|
– AC-to-ASC mapping table |
|
|
– AC-to-ASC mapping |
6 (AC0-9) |
|
– AC-to-ASC mapping |
5 (AC10) |
|
– AC-to-ASC mapping |
4 (AC11) |
|
– AC-to-ASC mapping |
3 (AC12) |
|
– AC-to-ASC mapping |
2 (AC13) |
|
– AC-to-ASC mapping |
1 (AC14) |
|
– AC-to-ASC mapping |
0 (AC15) |
|
– CHOICE mode |
TDD (no data) |
|
– Secondary CCPCH system information |
(MP – but treated as if not received by UE) |
|
– Secondary CCPCH system information list |
(MP – but treated as if not received by UE) |
|
– Secondary CCPCH info |
|
|
– CHOICE mode |
1.28 Mcps TDD or 3.84 Mcps TDD |
|
– Offset |
0 |
|
– Common timeslot info |
|
|
– 2nd interleaving mode |
Not Present (MD "Frame") |
|
– TFCI coding |
Not Present (MD) |
|
– Puncturing limit |
1.0 |
|
– Repetition period |
Not Present (MD "1") |
|
– Repetition length |
Not present (empty) |
|
– Individual timeslot info |
|
|
– CHOICE TDD option |
1.28 Mcps TDD |
|
– Timeslot number |
1 |
|
– TFCI existence |
FALSE |
|
– Midamble Shift and burst type |
|
|
– CHOICE TDD option |
1.28 Mcps TDD |
|
– Midamble Allocation Mode |
Default midamble |
|
– Midamble configuration |
16 |
|
– CHOICE TDD option |
1.28 Mcps TDD |
|
– Modulation |
QPSK |
|
– SS-TPC Symbols |
1 |
|
– Code List |
|
|
– Channelisation Code |
16/1 |
|
– TFCS |
Not Present |
|
– FACH/PCH information list |
Not Present |
|
– PICH info |
Not Present |
|
– MCCH configuration information |
Not Present |
|
– CBS DRX Level 1 information |
Not Present |
|
– Frequency band indicator |
Not Present |
|
– Frequency band indicator 2 |
Not Present |
|
– HSDPA cell Indicator |
Not Present (Default ‘HSDPA capability not indicated’) |
|
– E-DCH cell Indicator |
Not Present (Default ‘E-DCH capability not indicated’) |
|
– Secondary CCPCH system information MBMS |
|
|
– Secondary CCPCH system information |
|
|
– Secondary CCPCH info MBMS |
|
|
– CHOICE mode |
1.28 Mcps TDD |
|
– Common timeslot info MBMS |
|
|
– 2nd interleaving mode |
Frame |
|
– TFCI coding |
Reference clause 6.11 "Parameter Set" |
|
– Puncturing limit |
Reference clause 6.11 "Parameter Set" |
|
– Downlink Timeslots and Codes |
|
|
– First Individual timeslot info |
|
|
– Timeslot number |
|
|
– CHOICE TDD option |
1.28 Mcps TDD |
|
– Timeslot number |
0 |
|
– TFCI existence |
FALSE |
|
– Midamble Shift and burst type |
|
|
– CHOICE TDD option |
1.28 Mcps TDD |
|
– Midamble Allocation Mode |
Default midamble |
|
– Midamble configuration |
16 |
|
– CHOICE TDD option |
1.28 Mcps TDD |
|
– Modulation |
QPSK |
|
– SS-TPC Symbols |
1 |
|
– First timeslot channelisation codes |
|
|
– CHOICE codes representation |
Reference clause 5.5.2 "Downlink physical channels code allocation for Signalling" |
|
– CHOICE more timeslots |
No more timeslots |
|
– no data |
|
|
– MBSFN Special Time Slot |
TS7 |
|
– Modulation |
QPSK |
|
– TFCS |
|
|
– CHOICE TFCI signalling |
Normal TFCI signalling |
|
– TFCI Field 1 information |
|
|
– CHOICE TFCS representation |
Complete reconfiguration |
|
– TFCS complete reconfiguration information |
|
|
– CHOICE CTFC Size |
2 bit |
|
– CTFC information |
|
|
– 2bit CTFC |
0 |
|
– Power offset information |
Not Present |
|
– CTFC information |
|
|
– 2bit CTFC |
1 |
|
– Power offset information |
Not Present |
|
– CTFC information |
|
|
– 2bit CTFC |
2 |
|
– Power offset information |
Not Present |
|
– CTFC information |
|
|
– 2bit CTFC |
3 |
|
– Power offset information |
Not Present |
|
– FACH carrying MCCH |
|
|
– TFS |
|
|
– CHOICE Transport channel type |
Common transport channels |
|
– Dynamic Transport Format Information |
|
|
– RLC Size |
Reference clause 6.11 "Parameter Set" |
|
– Number of TBs and TTI List |
Reference clause 6.11 "Parameter Set" |
|
– Number of Transport blocks |
Reference clause 6.10 "Parameter Set" |
|
– CHOICE mode |
TDD |
|
– Transmission Time Interval |
Not Present |
|
– CHOICE Logical Channel List |
ALL |
|
– no data |
|
|
– Semi-static Transport Format information |
|
|
– Transmission time interval |
Reference clause 6.11 "Parameter Set" |
|
– Type of channel coding |
Turbo |
|
– Coding Rate |
Not Present |
|
– Rate matching attribute |
Reference clause 6.11 "Parameter Set" |
|
– CRC size |
Reference clause 6.11 "Parameter Set" |
|
– MCCH configuration information |
|
|
– Access Info Period coefficient |
Reference clause 11.1.1 "MCCH configuration parameters" |
|
– Repetition Period coefficient |
Reference clause 11.1.1 "MCCH configuration parameters" |
|
– Modification period coefficient |
Reference clause 11.1.1 "MCCH configuration parameters" |
|
– RLC info |
|
|
– DL UM RLC LI size |
7 |
|
– DL Duplication Avoidance and Reordering info |
Not Present |
|
– DL Out of sequence delivery info |
|
|
– Timer_OSD |
Not Present |
|
– Window size OSD |
48 |
|
– TCTF presence |
FALSE |
|
– FACH carrying MTCH list |
Not Present |
|
– Scheduling information |
Not Present |
|
– CHOICE mode |
TDD |
|
– no data |
|
|
– TDD MBSFN information |
|
|
– Time slot list |
(This list describes all Timeslots (0…6) in the frame) |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
1.28 Mcps TDD |
|
– Timeslot number |
0 |
|
– Cell parameters ID |
1 |
|
– Timeslot Number |
(Repeated for each Timeslot (1…6) |
|
– CHOICE TDD option |
1.28 Mcps TDD |
|
– Timeslot number |
(1…6) |
|
– Cell parameters ID |
5 (Repeated for each Timeslot (1…6) |
Contents of System Information Block type 5 for cell No.31 (7.68 Mcps TDD)
|
– SIB6 indicator |
FALSE |
|
– PICH Power offset |
0 dB |
|
– CHOICE Mode |
TDD |
|
– PUSCH system information |
Not Present |
|
– PUSCH system information VHCR |
Not Present |
|
– PDSCH system information |
Not Present |
|
– TDD open loop power control |
|
|
– Primary CCPCH Tx Power |
30 dbm |
|
– CHOICE TDD option |
7.68 Mcps TDD |
|
– Alpha |
Not Present |
|
– PRACH Constant Value |
-10 |
|
– DPCH Constant Value |
-10 |
|
– PUSCH Constant Value |
Not Present |
|
– UE positioning related parameters |
Not Present |
|
– Primary CCPCH info |
Not Present |
|
– PRACH system information list |
|
|
– PRACH system information |
|
|
– PRACH info |
|
|
– CHOICE mode |
TDD |
|
– CHOICE TDD option |
7.68 Mcps TDD |
|
– Timeslot number |
14 |
|
– PRACH Channelisation Code List VHCR |
|
|
– CHOICE SF |
SF16 |
|
– Channelisation Code List |
|
|
– Channelisation Code |
16/1 |
|
– PRACH Midamble |
Direct |
|
– PNBSCH allocation |
Not Present |
|
– Transport channel Identity |
15 |
|
– RACH TFS |
|
|
– CHOICE Transport channel type |
Common transport channels |
|
– Dynamic Transport format information |
|
|
– RLC size |
16 |
|
– Number of TBs and TTI List |
|
|
– Number of Transport blocks |
0 |
|
– CHOICE Mode |
TDD |
|
– Transmission Time Interval |
Not Present |
|
– CHOICE Logical channel List |
ALL |
|
– Semi-static Transport Format information |
|
|
– Transmission time interval |
10 |
|
– Type of channel coding |
No coding |
|
– Coding Rate |
Not Present |
|
– Rate matching attribute |
1 |
|
– CRC size |
0 |
|
– Additional RACH TFS for CCCH |
Not present |
|
– RACH TFCS |
Not present |
|
– Additional RACH TFCS for CCCH |
Not present |
|
– Persistence scaling factors |
Not Present |
|
– AC-to-ASC mapping |
|
|
– AC-to-ASC mapping table |
|
|
– AC-to-ASC mapping |
6 (AC0-9) |
|
– AC-to-ASC mapping |
5 (AC10) |
|
– AC-to-ASC mapping |
4 (AC11) |
|
– AC-to-ASC mapping |
3 (AC12) |
|
– AC-to-ASC mapping |
2 (AC13) |
|
– AC-to-ASC mapping |
1 (AC14) |
|
– AC-to-ASC mapping |
0 (AC15) |
|
– CHOICE mode |
TDD (no data) |
|
– Secondary CCPCH system information |
(MP – but treated as if not received by UE) |
|
– Secondary CCPCH system information list |
(MP – but treated as if not received by UE) |
|
– Secondary CCPCH info |
|
|
– CHOICE mode |
7.68 Mcps TDD |
|
– Offset |
0 |
|
– Common timeslot info |
|
|
– 2nd interleaving mode |
Not Present (MD "Frame") |
|
– TFCI coding |
Not Present (MD) |
|
– Puncturing limit |
1.0 |
|
– Repetition period |
Not Present (MD "1") |
|
– Repetition length |
Not present (empty) |
|
– Individual timeslot info |
|
|
– CHOICE TDD option |
7.68 Mcps TDD |
|
– Timeslot number |
1 |
|
– TFCI existence |
FALSE |
|
– Midamble Shift and burst type |
|
|
– CHOICE TDD option |
7.68 Mcps TDD |
|
– CHOICE Burst Type |
MBSFN Burst Type |
|
– no data |
|
|
– CHOICE TDD option |
7.68 Mcps TDD |
|
– no data |
|
|
– Code List |
|
|
– Channelisation Code |
32/1 |
|
– TFCS |
(MP – but treated as if not received by UE) |
|
-CHOICE TFCI signalling |
Normal TFCI signalling |
|
– TFCI Field 1 information |
|
|
– CHOICE TFCS representation |
Complete reconfiguration |
|
– TFCS complete reconfiguration information |
|
|
– CHOICE CTFC Size |
2 bit CTFC |
|
– CTFC information |
|
|
– 2 bit CTFC |
0 |
|
– Power offset information |
Not Present |
|
– FACH/PCH information |
(MP – but treated as if not received by UE) |
|
– TFS |
(PCH) |
|
– CHOICE Transport channel type |
Common transport channels |
|
– Dynamic Transport format information |
|
|
– RLC Size |
16 |
|
– Number of TBs and TTI List |
|
|
– Number of Transport blocks |
0 |
|
– CHOICE mode |
TDD |
|
– Transmission Time Interval |
10 |
|
– CHOICE Logical channel List |
ALL |
|
– Semi-static Transport Format information |
|
|
– Transmission time interval |
10 |
|
– Type of channel coding |
No coding |
|
– Coding Rate |
Not Present |
|
– Rate matching attribute |
1 |
|
– CRC size |
0 |
|
– Transport channel Identity |
1 |
|
– CTCH indicator |
FALSE |
|
– PICH info |
Not Present |
|
– MCCH configuration information |
Not Present |
|
– CBS DRX Level 1 information |
Not Present |
|
– Frequency band indicator |
Not Present |
|
– Frequency band indicator 2 |
Not Present |
|
– HSDPA cell Indicator |
Not Present (Default ‘HSDPA capability not indicated’) |
|
– E-DCH cell Indicator |
Not Present (Default ‘E-DCH capability not indicated’) |
|
– Secondary CCPCH system information MBMS |
|
|
– Secondary CCPCH system information |
|
|
– Secondary CCPCH info MBMS |
|
|
– CHOICE mode |
7.68 Mcps TDD |
|
– Common timeslot info MBMS |
|
|
– 2nd interleaving mode |
Frame |
|
– TFCI coding |
Reference clause 6.10 "Parameter Set" |
|
– Puncturing limit |
Reference clause 6.10 "Parameter Set" |
|
– Downlink Timeslots and Codes VHCR- |
|
|
– First Individual timeslot info |
|
|
– Timeslot number |
|
|
– CHOICE TDD option |
7.68 Mcps TDD |
|
– Timeslot number |
0 |
|
– TFCI existence |
Reference clause 6.10 "Parameter Set" |
|
– Midamble Shift and burst type |
|
|
– CHOICE TDD option |
7.68 Mcps TDD |
|
– CHOICE Burst Type |
MBSFN Burst Type |
|
– no data |
|
|
– CHOICE TDD option |
7.68 Mcps TDD |
|
– no data |
|
|
– First timeslot channelisation codes VHCR |
|
|
– CHOICE codes representation |
Reference clause 5.5.2 "Downlink physical channels code allocation for Signalling" |
|
– CHOICE more timeslots |
No more timeslots |
|
– no data |
|
|
– Modulation |
QPSK |
|
– TFCS |
|
|
– CHOICE TFCI signalling |
Normal TFCI signalling |
|
– TFCI Field 1 information |
|
|
– CHOICE TFCS representation |
Complete reconfiguration |
|
– TFCS complete reconfiguration information |
|
|
– CHOICE CTFC Size |
2 bit |
|
– CTFC information |
|
|
– 2bit CTFC |
0 |
|
– Power offset information |
Not Present |
|
– CTFC information |
|
|
– 2bit CTFC |
1 |
|
– Power offset information |
Not Present |
|
– CTFC information |
|
|
– 2bit CTFC |
2 |
|
– Power offset information |
Not Present |
|
– CTFC information |
|
|
– 2bit CTFC |
3 |
|
– Power offset information |
Not Present |
|
– FACH carrying MCCH |
|
|
– TFS |
|
|
– CHOICE Transport channel type |
Common transport channels |
|
– Dynamic Transport Format Information |
|
|
– RLC Size |
Reference clause 6.10 "Parameter Set" |
|
– Number of TBs and TTI List |
Reference clause 6.10 "Parameter Set" |
|
– Number of Transport blocks |
Reference clause 6.10 "Parameter Set" |
|
– CHOICE mode |
TDD |
|
– Transmission Time Interval |
Not Present |
|
– CHOICE Logical Channel List |
ALL |
|
– no data |
|
|
– Semi-static Transport Format information |
|
|
– Transmission time interval |
Reference clause 6.10 "Parameter Set" |
|
– Type of channel coding |
Turbo |
|
– Coding Rate |
Not Present |
|
– Rate matching attribute |
Reference clause 6.10 "Parameter Set" |
|
– CRC size |
Reference clause 6.10 "Parameter Set" |
|
– MCCH configuration information |
|
|
– Access Info Period coefficient |
Reference clause 11.1.1 "MCCH configuration parameters" |
|
– Repetition Period coefficient |
Reference clause 11.1.1 "MCCH configuration parameters" |
|
– Modification period coefficient |
Reference clause 11.1.1 "MCCH configuration parameters" |
|
– RLC info |
|
|
– DL UM RLC LI size |
7 |
|
– DL Duplication Avoidance and Reordering info |
Not Present |
|
– DL Out of sequence delivery info |
|
|
– Timer_OSD |
Not Present |
|
– Window size OSD |
48 |
|
– TCTF presence |
false |
|
– FACH carrying MTCH list |
Not Present |
|
– Scheduling information |
Not Present |
|
– CHOICE mode |
TDD |
|
– no data |
|
|
– TDD MBSFN information |
|
|
– Time slot list |
(This IE is repeated for all Timeslots (0…14) in the frame) |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
7.68 Mcps TDD |
|
– Timeslot number |
0 |
|
– Cell parameters ID |
1 |
|
– Timeslot Number |
(Repeated for each Timeslot (1…14) |
|
– CHOICE TDD option |
7.68 Mcps TDD |
|
– Timeslot number |
(1…14) |
|
– Cell parameters ID |
5 (Repeated for each Timeslot (1…14) |
Contents of System Information Block type 11 for cell No.31 (FDD)
|
– SIB 12 Indicator |
FALSE |
|
– FACH measurement occasion info |
Not Present |
|
– Measurement control system information |
|
|
– Use of HCS |
Not used |
|
– Cell selection and reselection quality measureCell |
CPICH RSCP |
|
– Intra-frequency measurement system information |
|
|
– Intra-frequency measurement identity |
Not Present |
|
– Intra-frequency cell info list |
|
|
– CHOICE intra-frequency cell removal |
Not present |
|
– New intra-frequency cells |
|
|
– Intra-frequency cell id |
31 |
|
– Cell info |
|
|
– Cell individual offset |
Not present (MD) Absence of this IE is equivalent to default value 0 dB |
|
– Reference time difference to cell |
Not Present |
|
– Read SFN Indicator |
FALSE |
|
– CHOICE mode |
FDD |
|
– Primary CCPCH info |
|
|
– Primary scrambling code |
Refer to clause titled "Default settings for cell No.31 (FDD)" in clause 6.1.4.4 |
|
– Primary CCPCH TX power |
Not Present |
|
– TX Diversity indicator |
FALSE |
|
– Cell Selection and Re-selection info |
Not Present (The IE shall be absent as this is the serving cell) |
|
– Intra-frequency cell id |
32 |
|
– Cell info |
|
|
– Cell individual offset |
Not present (MD) Absence of this IE is equivalent to default value 0 dB |
|
– Reference time difference to cell |
Not Present |
|
– Read SFN Indicator |
FALSE |
|
– CHOICE mode |
FDD |
|
– Primary CCPCH info |
|
|
– Primary scrambling code |
Refer to clause titled "Default settings for cell No.32 (FDD)" in clause 6.1.4.4 |
|
– Primary CCPCH TX power |
Not Present |
|
– TX Diversity indicator |
FALSE |
|
– Cell Selection and Re-selection info |
Not Present (The IE shall be absent as this is the serving cell) |
|
– Intra-frequency cell id |
37 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 with the exception that value for Cell Parameters ID shall be according to clause titled “Default settings for cell No.37 (FDD)” in clause 6.1.4.4 |
|
– Intra-frequency cell id |
38 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 with the exception that value for Cell Parameters ID shall be according to clause titled “Default settings for cell No.38 (FDD)” in clause 6.1.4.4 |
|
– Cells for measurement |
Not Present |
|
– Intra-frequency measurement quantity |
Not Present |
|
– Intra-frequency reporting quantity for RACH Reporting |
Not Present |
|
– Maximum number of reported cells on RACH |
Not Present |
|
– Reporting information for state CELL_DCH |
Not Present |
|
– Inter-frequency measurement system information |
Not Present |
|
– Inter-RAT measurement system information |
Not Present |
|
– Traffic volume measurement system information |
Not Present |
|
– MBSFN frequency list |
Not Present- |
Contents of System Information Block type 11 for cell No.31 (3.84 Mcps and 7.68 Mcps TDD)
|
– SIB 12 Indicator |
FALSE |
|
– FACH measurement occasion info |
Not Present |
|
– Measurement control system information |
|
|
– Use of HCS |
Not used |
|
– Cell selection and reselection quality measureCell |
CPICH RSCP |
|
– Intra-frequency measurement system information |
|
|
– Intra-frequency measurement identity |
Not Present |
|
– Intra-frequency cell info list |
|
|
– CHOICE intra-frequency cell removal |
Not present |
|
– New intra-frequency cells |
|
|
– Intra-frequency cell id |
31 |
|
– Cell info |
|
|
– Cell individual offset |
Not present (MD) |
|
– Reference time difference to cell |
Not Present |
|
– Read SFN Indicator |
FALSE |
|
– CHOICE mode |
TDD |
|
– Primary CCPCH info |
|
|
– CHOICE mode |
TDD |
|
– CHOICE TDD option |
3.84 and 7.68 Mcps TDD |
|
– CHOICE SyncCase |
Not Present |
|
– Cell parameters ID |
Refer to clause titled “Default settings for cell No.31 (3.84/7.68 Mcps TDD)” in clause 6.1.4.4 |
|
– SCTD indicator |
FALSE |
|
– Primary CCPCH TX power |
Not Present |
|
– Timeslot list |
Not Present |
|
– Cell Selection and Re-selection info |
Not Present (The IE shall be absent as this is the serving cell) |
|
– Intra-frequency cell id |
32 |
|
– Cell info |
|
|
– Cell individual offset |
Not present (MD) |
|
– Reference time difference to cell |
Not Present |
|
– Read SFN Indicator |
FALSE |
|
– CHOICE mode |
TDD |
|
– Primary CCPCH info |
|
|
– CHOICE mode |
TDD |
|
– CHOICE TDD option |
3.84 and 7.68 Mcps TDD |
|
– CHOICE Synccase |
Not Present |
|
– Cell parameters ID |
Refer to clause titled "Default settings for cell No.32 (3.84/7.68 Mcps TDD)" in clause 6.1.4.4 |
|
– Primary CCPCH TX power |
Not Present |
|
– Timeslot list |
Not Present |
|
– Cell Selection and Re-selection info |
Not Present |
|
– Intra-frequency cell id |
37 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 with the exception that value for Cell Parameters ID shall be according to clause titled “Default settings for cell No.37 (3.84/7.68 Mcps TDD)” in clause 6.1.4.4 |
|
– Intra-frequency cell id |
38 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 with the exception that value for Cell Parameters ID shall be according to clause titled “Default settings for cell No.38 (3.84/7.68 Mcps TDD)” in clause 6.1.4.4 |
|
– Cells for measurement |
Not Present |
|
– Intra-frequency measurement quantity |
Not Present |
|
– Intra-frequency reporting quantity for RACH Reporting |
Not Present |
|
– Maximum number of reported cells on RACH |
Not Present |
|
– Reporting information for state CELL_DCH |
Not Present |
|
– Inter-frequency measurement system information |
Not Present |
|
– Inter-RAT measurement system information |
Not Present |
|
– Traffic volume measurement system information |
Not Present |
|
– MBSFN frequency list |
Not Present- |
Contents of System Information Block type 11 for cell No.31 (3.84 Mcps TDD IMB)
|
– SIB 12 Indicator |
FALSE |
|
– FACH measurement occasion info |
Not Present |
|
– Measurement control system information |
|
|
– Use of HCS |
Not used |
|
– Cell selection and reselection quality measureCell |
CPICH RSCP |
|
– Intra-frequency measurement system information |
Not present |
|
– Inter-frequency measurement system information |
Not Present |
|
– Inter-RAT measurement system information |
Not Present |
|
– Traffic volume measurement system information |
Not Present |
|
– MBSFN frequency list |
Not Present- |
Contents of System Information Block type 11 for cell No.31 (1.28 Mcps TDD)
|
– SIB 12 Indicator |
FALSE |
|
– FACH measurement occasion info |
Not Present |
|
– Measurement control system information |
|
|
– Use of HCS |
Not used |
|
– Cell selection and reselection quality measureCell |
CPICH RSCP |
|
– Intra-frequency measurement system information |
|
|
– Intra-frequency measurement identity |
Not Present |
|
– Intra-frequency cell info list |
|
|
– CHOICE intra-frequency cell removal |
Not present |
|
– New intra-frequency cells |
|
|
– Intra-frequency cell id |
31 |
|
– Cell info |
|
|
– Cell individual offset |
Not present (MD) |
|
– Reference time difference to cell |
Not Present |
|
– Read SFN Indicator |
FALSE |
|
– CHOICE mode |
TDD |
|
– Primary CCPCH info |
|
|
– CHOICE mode |
TDD |
|
– CHOICE TDD option |
1.28 Mcps TDD |
|
– TSTD indicator |
FALSE |
|
– Cell parameters ID |
Refer to clause titled “Default settings for cell No.31 (1.28 Mcps TDD)” in clause 6.1.4.4 |
|
– SCTD indicator |
FALSE |
|
– Primary CCPCH TX power |
Not Present |
|
– Timeslot list |
Not Present |
|
– Cell Selection and Re-selection info |
Not Present (The IE shall be absent as this is the serving cell) |
|
– Intra-frequency cell id |
32 |
|
– Cell info |
|
|
– Cell individual offset |
Not present (MD) |
|
– Reference time difference to cell |
Not Present |
|
– Read SFN Indicator |
FALSE |
|
– CHOICE mode |
TDD |
|
– Primary CCPCH info |
|
|
– CHOICE mode |
TDD |
|
– CHOICE TDD option |
1.28 Mcps TDD |
|
– TSTD indicator |
FALSE |
|
– Cell parameters ID |
Refer to clause titled "Default settings for cell No.32 (1.28 Mcps TDD)" in clause 6.1.4.4 |
|
– Primary CCPCH TX power |
Not Present |
|
– Timeslot list |
Not Present |
|
– Cell Selection and Re-selection info |
Not Present |
|
– Intra-frequency cell id |
37 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 with the exception that value for Cell Parameters ID shall be according to clause titled “Default settings for cell No.37 (1.28 Mcps TDD)” in clause 6.1.4.4 |
|
– Intra-frequency cell id |
38 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 with the exception that value for Cell Parameters ID shall be according to clause titled “Default settings for cell No.38 (1.28 Mcps TDD)” in clause 6.1.4.4 |
|
– Cells for measurement |
Not Present |
|
– Intra-frequency measurement quantity |
Not Present |
|
– Intra-frequency reporting quantity for RACH Reporting |
Not Present |
|
– Maximum number of reported cells on RACH |
Not Present |
|
– Reporting information for state CELL_DCH |
Not Present |
|
– Inter-frequency measurement system information |
Not Present |
|
– Inter-RAT measurement system information |
Not Present |
|
– Traffic volume measurement system information |
Not Present |
|
– MBSFN frequency list |
Not Present- |
Cell No.32
The contents of SYSTEM INFORMATION BLOCK TYPE 3, 5 and 11 messages for cell No.32 are identical to those of cell No.31 with the following exceptions.
|
Cell identity |
0000 0000 0000 0000 0000 0010 0000B |
Default settings for cell No.32 (FDD)
|
Downlink input level |
Reference clause 6.10 "Parameter Set" |
|
Uplink output power |
Minimum supported by the UE’s power class. |
|
PCCPCH/PCPICH carrier number |
Reference clause 6.10 "Parameter Set" |
|
Cell Channel Description |
|
|
– Primary CPICH info |
|
|
– Primary scrambling code |
170 |
Default settings for cell No.32 (TDD)
|
Downlink input level |
Reference clause 6.1.6 |
|
PCCPCH/PCPICH carrier number |
Reference clause 5.1.2 |
|
Cell Channel Description |
|
|
– Primary CCPCH info |
|
|
– Cell parameters ID |
9 |
Default settings for cell No.31 (3.84 Mcps TDD IMB)
|
Downlink input level |
Reference clause 6.1.6.1 " Reference Radio Conditions (3.84 Mcps TDD IMB)" |
|
PCCPCH/PCPICH carrier number |
Reference clause 5.1.2 |
|
Cell Channel Description |
|
|
– Primary CPICH info |
|
|
– Primary scrambling code |
256 |
Contents of System Information Block type 5 for cell No.32 (FDD)
FFS
Contents of System Information Block type 5 for cell No.32 (3.84 Mcps TDD)
|
– TDD MBSFN information |
|
|
– Time slot list |
(This list describes all Timeslots (0…14) in the frame) |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD |
|
– Timeslot number |
0 |
|
– Cell parameters ID |
9 |
|
– Timeslot Number |
(Repeated for each Timeslot (1…14) |
|
– CHOICE TDD option |
3.84 Mcps TDD |
|
– Timeslot number |
(1…14) |
|
– Cell parameters ID |
5 (Repeated for each Timeslot (1…14) |
Contents of System Information Block type 5 for cell No.32 (1.28 Mcps TDD)
|
– TDD MBSFN information |
|
|
– Time slot list |
(This list describes all Timeslots (0…6) in the frame) |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
1.28 Mcps TDD |
|
– Timeslot number |
0 |
|
– Cell parameters ID |
9 |
|
– Timeslot Number |
(Repeated for each Timeslot (1…6) |
|
– CHOICE TDD option |
1.28 Mcps TDD |
|
– Timeslot number |
(1…6) |
|
– Cell parameters ID |
5 (Repeated for each Timeslot (1…6) |
Contents of System Information Block type 5 for cell No.32 (7.68 Mcps TDD)
|
– TDD MBSFN information |
|
|
– Time slot list |
(This list describes all Timeslots (0…14) in the frame) |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
7.68 Mcps TDD |
|
– Timeslot number |
0 |
|
– Cell parameters ID |
9 |
|
– Timeslot Number |
(Repeated for each Timeslot (1…14) |
|
– CHOICE TDD option |
7.68 Mcps TDD |
|
– Timeslot number |
(1…14) |
|
– Cell parameters ID |
5 (Repeated for each Timeslot (1…14) |
Contents of System Information Block type 11 for cell No.32 (FDD)
|
– Intra-frequency measurement system information |
|
|
…. |
|
|
– New intra-frequency cells |
|
|
– Intra-frequency cell id |
32 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=31 (serving cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.32 (FDD)" in clause 6.1.4.4 |
|
– Intra-frequency cell id |
31 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 (neighbour cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell Parameters ID shall be according to clause titled “Default settings for cell No.31 (FDD)” in clause 6.1.4.4 |
|
– Intra-frequency cell id |
37 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 (neighbour cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell Parameters ID shall be according to clause titled “Default settings for cell No.37 (FDD)” in clause 6.1.4.4 |
|
– Intra-frequency cell id |
38 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 (neighbour cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell Parameters ID shall be according to clause titled “Default settings for cell No.38 (FDD)” in clause 6.1.4.4 |
Contents of System Information Block type 11 for cell No.32 (3.84 Mcps and 7.68 Mcps TDD)
|
– Intra-frequency measurement system information |
|
|
…. |
|
|
– New intra-frequency cells |
|
|
– Intra-frequency cell id |
32 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=31 (serving cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.32 (3.84/7.68 Mcps TDD)" in clause 6.1.4.4 |
|
– Intra-frequency cell id |
31 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 (neighbour cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell Parameters ID shall be according to clause titled “Default settings for cell No.31 (3.84/7.68 Mcps TDD)” in clause 6.1.4.4 |
|
– Intra-frequency cell id |
37 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 (neighbour cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell Parameters ID shall be according to clause titled “Default settings for cell No.37 (3.84/7.68 Mcps TDD)” in clause 6.1.4.4 |
|
– Intra-frequency cell id |
38 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 (neighbour cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell Parameters ID shall be according to clause titled “Default settings for cell No.38 (3.84/7.68 Mcps TDD)” in clause 6.1.4.4 |
Contents of System Information Block type 11 for cell No.32 (1.28 Mcps TDD)
|
– Intra-frequency measurement system information |
|
|
…. |
|
|
– New intra-frequency cells |
|
|
– Intra-frequency cell id |
32 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=31 (serving cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.32 (1.28 Mcps TDD)" in clause 6.1.4.4 |
|
– Intra-frequency cell id |
31 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 (neighbour cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell Parameters ID shall be according to clause titled “Default settings for cell No.31 (1.28 Mcps TDD)” in clause 6.1.4.4 |
|
– Intra-frequency cell id |
37 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 (neighbour cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell Parameters ID shall be according to clause titled “Default settings for cell No.37 (1.28 Mcps TDD)” in clause 6.1.4.4 |
|
– Intra-frequency cell id |
38 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 (neighbour cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell Parameters ID shall be according to clause titled “Default settings for cell No.38 (1.28 Mcps TDD)” in clause 6.1.4.4 |
Cell No.33
The contents of SYSTEM INFORMATION BLOCK TYPE 3, 5 and 11 messages for cell No.33 are identical to those of cell No.31 with the following exceptions.
|
Cell identity |
0000 0000 0000 0000 0000 0010 0001B |
Default settings for cell No.33 (FDD)
|
Downlink input level |
Reference clause 6.10 "Parameter Set" |
|
Uplink output power |
Minimum supported by the UE’s power class. |
|
PCCPCH/PCPICH carrier number |
Reference clause 6.10 "Parameter Set" |
|
Cell Channel Description |
|
|
– Primary CPICH info |
|
|
– Primary scrambling code |
220 |
Default settings for cell No.33 (TDD)
|
Downlink input level |
Reference clause 6.1.6 |
|
PCCPCH/PCPICH carrier number |
Reference clause 5.1.2 |
|
Cell Channel Description |
|
|
– Primary CCPCH info |
|
|
– Cell parameters ID |
126 |
Default settings for cell No.33 (3.84 Mcps TDD IMB)
|
Downlink input level |
Reference clause 6.1.6.1 " Reference Radio Conditions (3.84 Mcps TDD IMB)" |
|
PCCPCH/PCPICH carrier number |
Reference clause 5.1.2 |
|
Cell Channel Description |
|
|
– Primary CPICH info |
|
|
– Primary scrambling code |
384 |
Contents of System Information Block type 5 for cell No.33 (FDD)
FFS
Contents of System Information Block type 5 for cell No.33 (3.84 Mcps and 7.68 Mcps TDD)
|
– TDD MBSFN information |
|
|
– Time slot list |
|
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
0 |
|
– Cell parameters ID |
126 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
1 |
|
– Cell parameters ID |
122 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
2 |
|
– Cell parameters ID |
122 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
3 |
|
– Cell parameters ID |
122 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
4 |
|
– Cell parameters ID |
126 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
5 |
|
– Cell parameters ID |
126 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
6 |
|
– Cell parameters ID |
126 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
7 |
|
– Cell parameters ID |
126 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
8 |
|
– Cell parameters ID |
122 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
9 |
|
– Cell parameters ID |
122 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
10 |
|
– Cell parameters ID |
122 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
11 |
|
– Cell parameters ID |
126 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
12 |
|
– Cell parameters ID |
126 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
13 |
|
– Cell parameters ID |
126 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
14 |
|
– Cell parameters ID |
126 |
Contents of System Information Block type 5 for cell No.33 (1.28 Mcps TDD)
|
– TDD MBSFN information |
|
|
– Time slot list |
|
|
– Timeslot Number |
|
|
– CHOICE TDD option |
1.28 Mcps TDD (as appropriate) |
|
– Timeslot number |
0 |
|
– Cell parameters ID |
126 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
1.28 Mcps TDD (as appropriate) |
|
– Timeslot number |
1 |
|
– Cell parameters ID |
122 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
1.28 Mcps TDD (as appropriate) |
|
– Timeslot number |
2 |
|
– Cell parameters ID |
122 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
1.28 Mcps TDD (as appropriate) |
|
– Timeslot number |
3 |
|
– Cell parameters ID |
122 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
1.28 Mcps TDD (as appropriate) |
|
– Timeslot number |
4 |
|
– Cell parameters ID |
126 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
1.28 Mcps TDD (as appropriate) |
|
– Timeslot number |
5 |
|
– Cell parameters ID |
126 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
1.28 Mcps TDD (as appropriate) |
|
– Timeslot number |
6 |
|
– Cell parameters ID |
126 |
Contents of System Information Block type 11 for cell No.33 (FDD)
|
– Intra-frequency measurement system information |
|
|
…. |
|
|
– New intra-frequency cells |
|
|
– Intra-frequency cell id |
33 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=31 (serving cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.33 (FDD)" in clause 6.1.4.4 |
|
– Intra-frequency cell id |
34 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 (neighbour cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell Parameters ID shall be according to clause titled “Default settings for cell No.34 (FDD)” in clause 6.1.4.4 |
|
– Intra-frequency cell id |
35 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 (neighbour cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell Parameters ID shall be according to clause titled “Default settings for cell No.35 (FDD)” in clause 6.1.4.4 |
|
– Intra-frequency cell id |
36 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 (neighbour cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell Parameters ID shall be according to clause titled “Default settings for cell No.36 (FDD)” in clause 6.1.4.4 |
Contents of System Information Block type 11 for cell No.33 (3.84 Mcps and 7.68 Mcps TDD)
|
– Intra-frequency measurement system information |
|
|
…. |
|
|
– New intra-frequency cells |
|
|
– Intra-frequency cell id |
33 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=31 (serving cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.33 (3.84/7.68 Mcps TDD)" in clause 6.1.4.4 |
|
– Intra-frequency cell id |
34 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 (neighbour cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell Parameters ID shall be according to clause titled “Default settings for cell No.34 (3.84/7.68 Mcps TDD)” in clause 6.1.4.4 |
|
– Intra-frequency cell id |
35 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 (neighbour cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell Parameters ID shall be according to clause titled “Default settings for cell No.35 (3.84/7.68 Mcps TDD)” in clause 6.1.4.4 |
|
– Intra-frequency cell id |
36 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 (neighbour cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell Parameters ID shall be according to clause titled “Default settings for cell No.36 (3.84/7.68 Mcps TDD)” in clause 6.1.4.4 |
Contents of System Information Block type 11 for cell No.33 (1.28 Mcps TDD)
|
– Intra-frequency measurement system information |
|
|
…. |
|
|
– New intra-frequency cells |
|
|
– Intra-frequency cell id |
33 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=31 (serving cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.33 (1.28 Mcps TDD)" in clause 6.1.4.4 |
|
– Intra-frequency cell id |
34 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 (neighbour cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell Parameters ID shall be according to clause titled “Default settings for cell No.34 (1.28 Mcps TDD)” in clause 6.1.4.4 |
|
– Intra-frequency cell id |
35 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 (neighbour cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell Parameters ID shall be according to clause titled “Default settings for cell No.35 (1.28 Mcps TDD)” in clause 6.1.4.4 |
|
– Intra-frequency cell id |
36 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 (neighbour cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell Parameters ID shall be according to clause titled “Default settings for cell No.36 (1.28 Mcps TDD)” in clause 6.1.4.4 |
Cell No.34
The contents of SYSTEM INFORMATION BLOCK TYPE 3, 5 and 11 messages for cell No.34 are identical to those of cell No.31 with the following exceptions.
|
Cell identity |
0000 0000 0000 0000 0000 0010 0010B |
Default settings for cell No.34 (FDD)
|
Downlink input level |
Reference clause 6.10 "Parameter Set" |
|
Uplink output power |
Minimum supported by the UE’s power class. |
|
PCCPCH/PCPICH carrier number |
Reference clause 6.10 "Parameter Set" |
|
Cell Channel Description |
|
|
– Primary CPICH info |
|
|
– Primary scrambling code |
270 |
Default settings for cell No.34 (TDD)
|
Downlink input level |
Reference clause 6.1.6 |
|
PCCPCH/PCPICH carrier number |
Reference clause 5.1.2 |
|
Cell Channel Description |
|
|
– Primary CCPCH info |
|
|
– Cell parameters ID |
118 |
Default settings for cell No.31 (3.84 Mcps TDD IMB)
|
Downlink input level |
Reference clause 6.1.6.1 " Reference Radio Conditions (3.84 Mcps TDD IMB)" |
|
PCCPCH/PCPICH carrier number |
Reference clause 5.1.2 |
|
Cell Channel Description |
|
|
– Primary CPICH info |
|
|
– Primary scrambling code |
512 |
Contents of System Information Block type 5 for cell No.34 (FDD)
FFS
Contents of System Information Block type 5 for cell No.34 (3.84 Mcps and 7.68 Mcps TDD)
|
– TDD MBSFN information |
|
|
– Time slot list |
|
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
0 |
|
– Cell parameters ID |
118 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
1 |
|
– Cell parameters ID |
122 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
2 |
|
– Cell parameters ID |
122 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
3 |
|
– Cell parameters ID |
122 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
4 |
|
– Cell parameters ID |
118 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
5 |
|
– Cell parameters ID |
118 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
6 |
|
– Cell parameters ID |
118 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
7 |
|
– Cell parameters ID |
118 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
8 |
|
– Cell parameters ID |
122 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
9 |
|
– Cell parameters ID |
122 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
10 |
|
– Cell parameters ID |
122 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
11 |
|
– Cell parameters ID |
118 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
12 |
|
– Cell parameters ID |
118 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
13 |
|
– Cell parameters ID |
118 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
14 |
|
– Cell parameters ID |
118 |
Contents of System Information Block type 5 for cell No.34 (1.28 Mcps TDD)
|
– TDD MBSFN information |
|
|
– Time slot list |
|
|
– Timeslot Number |
|
|
– CHOICE TDD option |
1.28 Mcps TDD (as appropriate) |
|
– Timeslot number |
0 |
|
– Cell parameters ID |
118 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
1.28 Mcps TDD (as appropriate) |
|
– Timeslot number |
1 |
|
– Cell parameters ID |
122 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
1.28 Mcps TDD (as appropriate) |
|
– Timeslot number |
2 |
|
– Cell parameters ID |
122 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
1.28 Mcps TDD (as appropriate) |
|
– Timeslot number |
3 |
|
– Cell parameters ID |
122 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
1.28 Mcps TDD (as appropriate) |
|
– Timeslot number |
4 |
|
– Cell parameters ID |
118 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
1.28 Mcps TDD (as appropriate) |
|
– Timeslot number |
5 |
|
– Cell parameters ID |
118 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
1.28 Mcps TDD (as appropriate) |
|
– Timeslot number |
6 |
|
– Cell parameters ID |
118 |
Contents of System Information Block type 11 for cell No.34 (FDD)
|
– Intra-frequency measurement system information |
|
|
…. |
|
|
– New intra-frequency cells |
|
|
– Intra-frequency cell id |
34 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=31 (serving cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.34 (FDD)" in clause 6.1.4.4 |
|
– Intra-frequency cell id |
33 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 (neighbour cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell Parameters ID shall be according to clause titled “Default settings for cell No.33 (FDD)” in clause 6.1.4.4 |
|
– Intra-frequency cell id |
35 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 (neighbour cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell Parameters ID shall be according to clause titled “Default settings for cell No.35 (FDD)” in clause 6.1.4.4 |
|
– Intra-frequency cell id |
36 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 (neighbour cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell Parameters ID shall be according to clause titled “Default settings for cell No.36 (FDD)” in clause 6.1.4.4 |
Contents of System Information Block type 11 for cell No.34 (3.84 Mcps and 7.68 Mcps TDD)
|
– Intra-frequency measurement system information |
|
|
…. |
|
|
– New intra-frequency cells |
|
|
– Intra-frequency cell id |
34 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=31 (serving cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.34 (3.84/7.68 Mcps TDD)" in clause 6.1.4.4 |
|
– Intra-frequency cell id |
33 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 (neighbour cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell Parameters ID shall be according to clause titled “Default settings for cell No.33 (3.84/7.68 Mcps TDD)” in clause 6.1.4.4 |
|
– Intra-frequency cell id |
35 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 (neighbour cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell Parameters ID shall be according to clause titled “Default settings for cell No.35 (3.84/7.68 Mcps TDD)” in clause 6.1.4.4 |
|
– Intra-frequency cell id |
36 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 (neighbour cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell Parameters ID shall be according to clause titled “Default settings for cell No.36 (3.84/7.68 Mcps TDD)” in clause 6.1.4.4 |
Contents of System Information Block type 11 for cell No.34 (1.28 Mcps TDD)
|
– Intra-frequency measurement system information |
|
|
…. |
|
|
– New intra-frequency cells |
|
|
– Intra-frequency cell id |
34 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=31 (serving cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.34 (1.28 Mcps TDD)" in clause 6.1.4.4 |
|
– Intra-frequency cell id |
33 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 (neighbour cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell Parameters ID shall be according to clause titled “Default settings for cell No.33 (1.28 Mcps TDD)” in clause 6.1.4.4 |
|
– Intra-frequency cell id |
35 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 (neighbour cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell Parameters ID shall be according to clause titled “Default settings for cell No.35 (1.28 Mcps TDD)” in clause 6.1.4.4 |
|
– Intra-frequency cell id |
36 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 (neighbour cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell Parameters ID shall be according to clause titled “Default settings for cell No.36 (1.28 Mcps TDD)” in clause 6.1.4.4 |
Cell No.35
The contents of SYSTEM INFORMATION BLOCK TYPE 3, 5 and 11 messages for cell No.35 are identical to those of cell No.31 with the following exceptions.
|
Cell identity |
0000 0000 0000 0000 0000 0010 0011B |
Default settings for cell No.35 (FDD)
|
Downlink input level |
Reference clause 6.10 "Parameter Set" |
|
Uplink output power |
Minimum supported by the UE’s power class. |
|
PCCPCH/PCPICH carrier number |
Reference clause 6.10 "Parameter Set" |
|
Cell Channel Description |
|
|
– Primary CPICH info |
|
|
– Primary scrambling code |
320 |
Default settings for cell No.35 (TDD)
|
Downlink input level |
Reference clause 6.1.6 |
|
PCCPCH/PCPICH carrier number |
Reference clause 5.1.2 |
|
Cell Channel Description |
|
|
– Primary CCPCH info |
|
|
– Cell parameters ID |
110 |
Default settings for cell No.31 (3.84 Mcps TDD IMB)
|
Downlink input level |
Reference clause 6.1.6.1 " Reference Radio Conditions (3.84 Mcps TDD IMB)" |
|
PCCPCH/PCPICH carrier number |
Reference clause 5.1.2 |
|
Cell Channel Description |
|
|
– Primary CPICH info |
|
|
– Primary scrambling code |
640 |
Contents of System Information Block type 5 for cell No.35 (FDD)
FFS
Contents of System Information Block type 5 for cell No.35 (3.84 Mcps and 7.68 Mcps TDD)
|
– TDD MBSFN information |
|
|
– Time slot list |
|
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
0 |
|
– Cell parameters ID |
110 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
1 |
|
– Cell parameters ID |
122 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
2 |
|
– Cell parameters ID |
122 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
3 |
|
– Cell parameters ID |
122 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
4 |
|
– Cell parameters ID |
110 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
5 |
|
– Cell parameters ID |
110 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
6 |
|
– Cell parameters ID |
110 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
7 |
|
– Cell parameters ID |
110 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
8 |
|
– Cell parameters ID |
122 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
9 |
|
– Cell parameters ID |
122 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
10 |
|
– Cell parameters ID |
122 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
11 |
|
– Cell parameters ID |
110 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
12 |
|
– Cell parameters ID |
110 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
13 |
|
– Cell parameters ID |
110 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
14 |
|
– Cell parameters ID |
110 |
Contents of System Information Block type 5 for cell No.35 (1.28 Mcps TDD)
|
– TDD MBSFN information |
|
|
– Time slot list |
|
|
– Timeslot Number |
|
|
– CHOICE TDD option |
1.28 Mcps TDD (as appropriate) |
|
– Timeslot number |
0 |
|
– Cell parameters ID |
110 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
1.28 Mcps TDD (as appropriate) |
|
– Timeslot number |
1 |
|
– Cell parameters ID |
122 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
1.28 Mcps TDD (as appropriate) |
|
– Timeslot number |
2 |
|
– Cell parameters ID |
122 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
1.28 Mcps TDD (as appropriate) |
|
– Timeslot number |
3 |
|
– Cell parameters ID |
122 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
1.28 Mcps TDD (as appropriate) |
|
– Timeslot number |
4 |
|
– Cell parameters ID |
110 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
1.28 Mcps TDD (as appropriate) |
|
– Timeslot number |
5 |
|
– Cell parameters ID |
110 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
1.28 Mcps TDD (as appropriate) |
|
– Timeslot number |
6 |
|
– Cell parameters ID |
110 |
Contents of System Information Block type 11 for cell No.35 (FDD)
|
– Intra-frequency measurement system information |
|
|
…. |
|
|
– New intra-frequency cells |
|
|
– Intra-frequency cell id |
35 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=31 (serving cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.35 (FDD)" in clause 6.1.4.4 |
|
– Intra-frequency cell id |
33 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 (neighbour cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell Parameters ID shall be according to clause titled “Default settings for cell No.33 (FDD)” in clause 6.1.4.4 |
|
– Intra-frequency cell id |
34 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 (neighbour cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell Parameters ID shall be according to clause titled “Default settings for cell No.34 (FDD)” in clause 6.1.4.4 |
|
– Intra-frequency cell id |
36 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 (neighbour cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell Parameters ID shall be according to clause titled “Default settings for cell No.36 (FDD)” in clause 6.1.4.4 |
Contents of System Information Block type 11 for cell No.35 (3.84 Mcps and 7.68 Mcps TDD)
|
– Intra-frequency measurement system information |
|
|
…. |
|
|
– New intra-frequency cells |
|
|
– Intra-frequency cell id |
35 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=31 (serving cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.35 (3.84/7.68 Mcps TDD)" in clause 6.1.4.4 |
|
– Intra-frequency cell id |
33 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 (neighbour cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell Parameters ID shall be according to clause titled “Default settings for cell No.33 (3.84/7.68 Mcps TDD)” in clause 6.1.4.4 |
|
– Intra-frequency cell id |
34 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 (neighbour cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell Parameters ID shall be according to clause titled “Default settings for cell No.34 (3.84/7.68 Mcps TDD)” in clause 6.1.4.4 |
|
– Intra-frequency cell id |
36 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 (neighbour cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell Parameters ID shall be according to clause titled “Default settings for cell No.36 (3.84/7.68 Mcps TDD)” in clause 6.1.4.4 |
Contents of System Information Block type 11 for cell No.35 (1.28 Mcps TDD)
|
– Intra-frequency measurement system information |
|
|
…. |
|
|
– New intra-frequency cells |
|
|
– Intra-frequency cell id |
35 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=31 (serving cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.35 (1.28 Mcps TDD)" in clause 6.1.4.4 |
|
– Intra-frequency cell id |
33 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 (neighbour cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell Parameters ID shall be according to clause titled “Default settings for cell No.33 (1.28 Mcps TDD)” in clause 6.1.4.4 |
|
– Intra-frequency cell id |
34 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 (neighbour cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell Parameters ID shall be according to clause titled “Default settings for cell No.34 (1.28 Mcps TDD)” in clause 6.1.4.4 |
|
– Intra-frequency cell id |
36 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 (neighbour cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell Parameters ID shall be according to clause titled “Default settings for cell No.36 (1.28 Mcps TDD)” in clause 6.1.4.4 |
Cell No.36
The contents of SYSTEM INFORMATION BLOCK TYPE 3, 5 and 11 messages for cell No.36 are identical to those of cell No.31 with the following exceptions.
|
Cell identity |
0000 0000 0000 0000 0000 0010 0100B |
Default settings for cell No.36 (FDD)
|
Downlink input level |
Reference clause 6 Parameter Set |
|
Uplink output power |
Minimum supported by the UE’s power class. |
|
PCCPCH/PCPICH carrier number |
Reference clause 6 Parameter Set |
|
Cell Channel Description |
|
|
– Primary CPICH info |
|
|
– Primary scrambling code |
370 |
Default settings for cell No.36 (TDD)
|
Downlink input level |
Reference clause 6.1.6 |
|
PCCPCH/PCPICH carrier number |
Reference clause 5.1.2 |
|
Cell Channel Description |
|
|
– Primary CCPCH info |
|
|
– Cell parameters ID |
102 |
Default settings for cell No.31 (3.84 Mcps TDD IMB)
|
Downlink input level |
Reference clause 6.1.6.1 " Reference Radio Conditions (3.84 Mcps TDD IMB)" |
|
PCCPCH/PCPICH carrier number |
Reference clause 5.1.2 |
|
Cell Channel Description |
|
|
– Primary CPICH info |
|
|
– Primary scrambling code |
768 |
Contents of System Information Block type 5 for cell No.36 (FDD)
FFS
Contents of System Information Block type 5 for cell No.36 (3.84 Mcps and 7.68 Mcps TDD)
|
– TDD MBSFN information |
|
|
– Time slot list |
|
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
0 |
|
– Cell parameters ID |
102 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
1 |
|
– Cell parameters ID |
122 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
2 |
|
– Cell parameters ID |
122 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
3 |
|
– Cell parameters ID |
122 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
4 |
|
– Cell parameters ID |
102 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
5 |
|
– Cell parameters ID |
102 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
6 |
|
– Cell parameters ID |
102 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
7 |
|
– Cell parameters ID |
102 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
8 |
|
– Cell parameters ID |
122 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
9 |
|
– Cell parameters ID |
122 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
10 |
|
– Cell parameters ID |
122 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
11 |
|
– Cell parameters ID |
102 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
12 |
|
– Cell parameters ID |
102 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
13 |
|
– Cell parameters ID |
102 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD or 7.68 Mcps TDD (as appropriate) |
|
– Timeslot number |
14 |
|
– Cell parameters ID |
102 |
Contents of System Information Block type 5 for cell No.36 (1.28 Mcps TDD)
|
– TDD MBSFN information |
|
|
– Time slot list |
|
|
– Timeslot Number |
|
|
– CHOICE TDD option |
1.28 Mcps TDD (as appropriate) |
|
– Timeslot number |
0 |
|
– Cell parameters ID |
102 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
1.28 Mcps TDD (as appropriate) |
|
– Timeslot number |
1 |
|
– Cell parameters ID |
122 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
1.28 Mcps TDD (as appropriate) |
|
– Timeslot number |
2 |
|
– Cell parameters ID |
122 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
1.28 Mcps TDD (as appropriate) |
|
– Timeslot number |
3 |
|
– Cell parameters ID |
122 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
1.28 Mcps TDD (as appropriate) |
|
– Timeslot number |
4 |
|
– Cell parameters ID |
102 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
1.28 Mcps TDD (as appropriate) |
|
– Timeslot number |
5 |
|
– Cell parameters ID |
102 |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
1.28 Mcps TDD (as appropriate) |
|
– Timeslot number |
6 |
|
– Cell parameters ID |
102 |
Contents of System Information Block type 11 for cell No.36 (FDD)
|
– Intra-frequency measurement system information |
|
|
…. |
|
|
– New intra-frequency cells |
|
|
– Intra-frequency cell id |
36 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=31 (serving cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.36 (FDD)" in clause 6.1.4.4 |
|
– Intra-frequency cell id |
33 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 (neighbour cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell Parameters ID shall be according to clause titled “Default settings for cell No.33 (FDD)” in clause 6.1.4.4 |
|
– Intra-frequency cell id |
34 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 (neighbour cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell Parameters ID shall be according to clause titled “Default settings for cell No.34 (FDD)” in clause 6.1.4.4 |
|
– Intra-frequency cell id |
35 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 (neighbour cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell Parameters ID shall be according to clause titled “Default settings for cell No.35 (FDD)” in clause 6.1.4.4 |
Contents of System Information Block type 11 for cell No.36 (3.84 Mcps and 7.68 Mcps TDD)
|
– Intra-frequency measurement system information |
|
|
…. |
|
|
– New intra-frequency cells |
|
|
– Intra-frequency cell id |
36 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=31 (serving cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.36 (3.84/7.68 Mcps TDD)" in clause 6.1.4.4 |
|
– Intra-frequency cell id |
33 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 (neighbour cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell Parameters ID shall be according to clause titled “Default settings for cell No.33 (3.84/7.68 Mcps TDD)” in clause 6.1.4.4 |
|
– Intra-frequency cell id |
34 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 (neighbour cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell Parameters ID shall be according to clause titled “Default settings for cell No.34 (3.84/7.68 Mcps TDD)” in clause 6.1.4.4 |
|
– Intra-frequency cell id |
35 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 (neighbour cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell Parameters ID shall be according to clause titled “Default settings for cell No.35 (3.84/7.68 Mcps TDD)” in clause 6.1.4.4 |
Contents of System Information Block type 11 for cell No.36 (1.28 Mcps TDD)
|
– Intra-frequency measurement system information |
|
|
…. |
|
|
– New intra-frequency cells |
|
|
– Intra-frequency cell id |
36 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=31 (serving cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.36 (1.28 Mcps TDD)" in clause 6.1.4.4 |
|
– Intra-frequency cell id |
33 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 (neighbour cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell Parameters ID shall be according to clause titled “Default settings for cell No.33 (1.28 Mcps TDD)” in clause 6.1.4.4 |
|
– Intra-frequency cell id |
34 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 (neighbour cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell Parameters ID shall be according to clause titled “Default settings for cell No.34 (1.28 Mcps TDD)” in clause 6.1.4.4 |
|
– Intra-frequency cell id |
35 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 (neighbour cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell Parameters ID shall be according to clause titled “Default settings for cell No.35 (1.28 Mcps TDD)” in clause 6.1.4.4 |
Cell No.37
The contents of SYSTEM INFORMATION BLOCK TYPE 3, 5 and 11 messages for cell No.37 are identical to those of cell No.31 with the following exceptions.
|
Cell identity |
0000 0000 0000 0000 0000 0010 0101B |
Default settings for cell No.37 (FDD)
|
Downlink input level |
Reference clause 6.10 "Parameter Set" |
|
Uplink output power |
Minimum supported by the UE’s power class. |
|
PCCPCH/PCPICH carrier number |
Reference clause 6.10 "Parameter Set" |
|
Cell Channel Description |
|
|
– Primary CPICH info |
|
|
– Primary scrambling code |
420 |
Default settings for cell No.37 (TDD)
|
Downlink input level |
Reference clause 6.1.6 |
|
PCCPCH/PCPICH carrier number |
Reference clause 5.1.2 |
|
Cell Channel Description |
|
|
– Primary CCPCH info |
|
|
– Cell parameters ID |
17 |
Default settings for cell No.31 (3.84 Mcps TDD IMB)
|
Downlink input level |
Reference clause 6.1.6.1 " Reference Radio Conditions (3.84 Mcps TDD IMB)" |
|
PCCPCH/PCPICH carrier number |
Reference clause 5.1.2 |
|
Cell Channel Description |
|
|
– Primary CPICH info |
|
|
– Primary scrambling code |
896 |
Contents of System Information Block type 5 for cell No.37 (FDD)
FFS
Contents of System Information Block type 5 for cell No.37 (3.84 Mcps TDD)
|
– TDD MBSFN information |
|
|
– Time slot list |
(This list describes all Timeslots (0…14) in the frame) |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD |
|
– Timeslot number |
0 |
|
– Cell parameters ID |
17 |
|
– Timeslot Number |
(Repeated for each Timeslot (1…14) |
|
– CHOICE TDD option |
3.84 Mcps TDD |
|
– Timeslot number |
(1…14) |
|
– Cell parameters ID |
5 (Repeated for each Timeslot (1…14) |
Contents of System Information Block type 5 for cell No.37 (1.28 Mcps TDD)
|
– TDD MBSFN information |
|
|
– Time slot list |
(This list describes all Timeslots (0…6) in the frame) |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
1.28 Mcps TDD |
|
– Timeslot number |
0 |
|
– Cell parameters ID |
17 |
|
– Timeslot Number |
(Repeated for each Timeslot (1…6) |
|
– CHOICE TDD option |
1.28 Mcps TDD |
|
– Timeslot number |
(1…6) |
|
– Cell parameters ID |
5 (Repeated for each Timeslot (1…6) |
Contents of System Information Block type 5 for cell No.37 (7.68 Mcps TDD)
|
– TDD MBSFN information |
|
|
– Time slot list |
(This list describes all Timeslots (0…14) in the frame) |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
7.68 Mcps TDD |
|
– Timeslot number |
0 |
|
– Cell parameters ID |
17 |
|
– Timeslot Number |
(Repeated for each Timeslot (1…14) |
|
– CHOICE TDD option |
7.68 Mcps TDD |
|
– Timeslot number |
(1…14) |
|
– Cell parameters ID |
5 (Repeated for each Timeslot (1…14) |
Contents of System Information Block type 11 for cell No.37 (FDD)
|
– Intra-frequency measurement system information |
|
|
…. |
|
|
– New intra-frequency cells |
|
|
– Intra-frequency cell id |
37 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=31 (serving cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.37 (FDD)" in clause 6.1.4.4 |
|
– Intra-frequency cell id |
31 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 (neighbour cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell Parameters ID shall be according to clause titled “Default settings for cell No.31 (FDD)” in clause 6.1.4.4 |
|
– Intra-frequency cell id |
32 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 (neighbour cell) in SIB11 for Cell 31 in clause 6.1.4.4 |
|
– Intra-frequency cell id |
38 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 (neighbour cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell Parameters ID shall be according to clause titled “Default settings for cell No.38 (FDD)” in clause 6.1.4.4 |
Contents of System Information Block type 11 for cell No.37 (3.84 Mcps and 7.68 Mcps TDD)
|
– Intra-frequency measurement system information |
|
|
…. |
|
|
– New intra-frequency cells |
|
|
– Intra-frequency cell id |
37 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=31 (serving cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.37 (3.84/7.68 Mcps TDD)" in clause 6.1.4.4 |
|
– Intra-frequency cell id |
31 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 (neighbour cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell Parameters ID shall be according to clause titled “Default settings for cell No.31 (3.84/7.68 Mcps TDD)” in clause 6.1.4.4 |
|
– Intra-frequency cell id |
32 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 (neighbour cell) in SIB11 for Cell 31 in clause 6.1.4.4 |
|
– Intra-frequency cell id |
38 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 (neighbour cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell Parameters ID shall be according to clause titled “Default settings for cell No.38 (3.84/7.68 Mcps TDD)” in clause 6.1.4.4 |
Contents of System Information Block type 11 for cell No.37 (1.28 Mcps TDD)
|
– Intra-frequency measurement system information |
|
|
…. |
|
|
– New intra-frequency cells |
|
|
– Intra-frequency cell id |
37 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=31 (serving cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.37 (1.28 Mcps TDD)" in clause 6.1.4.4 |
|
– Intra-frequency cell id |
31 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 (neighbour cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell Parameters ID shall be according to clause titled “Default settings for cell No.31 (1.28 Mcps TDD)” in clause 6.1.4.4 |
|
– Intra-frequency cell id |
32 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 (neighbour cell) in SIB11 for Cell 31 in clause 6.1.4.4 |
|
– Intra-frequency cell id |
38 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 (neighbour cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell Parameters ID shall be according to clause titled “Default settings for cell No.38 (1.28 Mcps TDD)” in clause 6.1.4.4 |
Cell No.38
The contents of SYSTEM INFORMATION BLOCK TYPE 3, 5 and 11 messages for cell No.38 are identical to those of cell No.31 with the following exceptions.
|
Cell identity |
0000 0000 0000 0000 0000 0010 0110B |
Default settings for cell No.38 (FDD)
|
Downlink input level |
Reference clause 6.10 "Parameter Set" |
|
Uplink output power |
Minimum supported by the UE’s power class. |
|
PCCPCH/PCPICH carrier number |
Reference clause 6.10 "Parameter Set" |
|
Cell Channel Description |
|
|
– Primary CPICH info |
|
|
– Primary scrambling code |
470 |
Default settings for cell No.38 (TDD)
|
Downlink input level |
Reference clause 6.1.6 |
|
PCCPCH/PCPICH carrier number |
Reference clause 5.1.2 |
|
Cell Channel Description |
|
|
– Primary CCPCH info |
|
|
– Cell parameters ID |
25 |
Default settings for cell No.31 (3.84 Mcps TDD IMB)
|
Downlink input level |
Reference clause 6.1.6.1 " Reference Radio Conditions (3.84 Mcps TDD IMB)" |
|
PCCPCH/PCPICH carrier number |
Reference clause 5.1.2 |
|
Cell Channel Description |
|
|
– Primary CPICH info |
|
|
– Primary scrambling code |
0 |
Contents of System Information Block type 5 for cell No.38 (FDD)
FFS
Contents of System Information Block type 5 for cell No.38 (3.84 Mcps TDD)
|
– TDD MBSFN information |
|
|
– Time slot list |
(This list describes all Timeslots (0…14) in the frame) |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
3.84 Mcps TDD |
|
– Timeslot number |
0 |
|
– Cell parameters ID |
25 |
|
– Timeslot Number |
(Repeated for each Timeslot (1…14) |
|
– CHOICE TDD option |
3.84 Mcps TDD |
|
– Timeslot number |
(1…14) |
|
– Cell parameters ID |
5 (Repeated for each Timeslot (1…14) |
Contents of System Information Block type 5 for cell No.38 (1.28 Mcps TDD)
|
– TDD MBSFN information |
|
|
– Time slot list |
(This list describes all Timeslots (0…6) in the frame) |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
1.28 Mcps TDD |
|
– Timeslot number |
0 |
|
– Cell parameters ID |
25 |
|
– Timeslot Number |
(Repeated for each Timeslot (1…6) |
|
– CHOICE TDD option |
1.28 Mcps TDD |
|
– Timeslot number |
(1…6) |
|
– Cell parameters ID |
5 (Repeated for each Timeslot (1…6) |
Contents of System Information Block type 5 for cell No.38 (7.68 Mcps TDD)
|
– TDD MBSFN information |
|
|
– Time slot list |
(This list describes all Timeslots (0…14) in the frame) |
|
– Timeslot Number |
|
|
– CHOICE TDD option |
7.68 Mcps TDD |
|
– Timeslot number |
0 |
|
– Cell parameters ID |
25 |
|
– Timeslot Number |
(Repeated for each Timeslot (1…14) |
|
– CHOICE TDD option |
7.68 Mcps TDD |
|
– Timeslot number |
(1…14) |
|
– Cell parameters ID |
5 (Repeated for each Timeslot (1…14) |
Contents of System Information Block type 11 for cell No.38 (FDD)
|
– Intra-frequency measurement system information |
|
|
…. |
|
|
– New intra-frequency cells |
|
|
– Intra-frequency cell id |
38 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=31 (serving cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.38 (FDD)" in clause 6.1.4.4 |
|
– Intra-frequency cell id |
31 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 (neighbour cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell Parameters ID shall be according to clause titled “Default settings for cell No.31 (FDD)” in clause 6.1.4.4 |
Contents of System Information Block type 11 for cell No.38 (3.84 Mcps and 7.68 Mcps TDD)
|
– Intra-frequency measurement system information |
|
|
…. |
|
|
– New intra-frequency cells |
|
|
– Intra-frequency cell id |
38 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=31 (serving cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.38 (3.84/7.68 Mcps TDD)" in clause 6.1.4.4 |
|
– Intra-frequency cell id |
31 |
|
– Cell info |
Same content as specified for intra-frequency cell id=32 (neighbour cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell Parameters ID shall be according to clause titled “Default settings for cell No.31 (3.84/7.68 Mcps TDD)” in clause 6.1.4.4 |
Contents of System Information Block type 11 for cell No.38 (1.28 Mcps TDD)
|
– Intra-frequency measurement system information |
|
|
…. |
|
|
– New intra-frequency cells |
|
|
– Intra-frequency cell id |
38 |
|
– Cell info |
Same content as specified for Intra-frequency cell id=31 (serving cell) in SIB11 for Cell 31 in clause 6.1.4.4 with the exception that value for Cell parameters ID shall be according to clause titled "Default settings for cell No.38 (1.28 Mcps TDD)" in clause 6.1.4.4 |
|
– Intra-frequency cell id |
31 |
|
– Cell info |