6.1.0a Default Master Information Block and Scheduling Block messages

34.1083GPPCommon test environments for User Equipment (UE)Conformance testingRelease 15TS

6.1.0a.1 Grouping SIBs for testing

Mandatory in 34.108

Used in Idle Mode

MIB, SB1, (SB2), SIB1, SIB2, SIB3, SIB5/SIB5bis, SIB7, SIB11

Used in Connected Mode

SIB4, SIB6, SIB12

Mandatory for FDD CPCH (R99 and Rel-4 only)

SIB8, SIB9

Mandatory for FDD DRAC

SIB10

Mandatory for TDD

SIB14, SIB17

Mandatory for LCS

SIB15, SIB15.1, SIB15.2, SIB15.3

Mandatory for ANSI-41 system

SIB13, SIB13.1, SIB13.2, SIB13.3, SIB13.4

Mandatory for InterSys HO from GERAN To UTRAN

SIB16

Mandatory for Cell reselection

SIB18

Mandatory for Inter-RAT frequencies and priority information

SIB19

Mandatory for EAB

SIB21

Mandatory for Concurrent deployment of 2ms and 10ms TTI in a cell, NodeB triggered HS-DPCCH transmission, Fallback to R99 PRACH, TTI alignment, Per HARQ process activation and de-activation and HS-DSCH DRX operation with second DRX cycle in CELL_FACH

SIB22

Mandatory for RAN assisted WLAN interworking

SIB23

6.1.0a.2 SIB configurations

The following SIB configurations are used.

Configuration 1 is the default. It is used for the following test case scenarios:

  • UTRAN/FDD only SYSTEM.
  • UTRAN/FDD + GERAN SYSTEM (not involving inter-RAT handover from GERAN to UTRAN).
  • UTRAN/TDD only SYSTEM.
  • UTRAN/TDD + GERAN SYSTEM (not involving inter-RAT handover from GERAN to UTRAN).
  • inter-RAT handover from GERAN to UTRAN test cases.

Configuration 2 is for test cases which need two S_CCPCH or two PRACH.

Configuration 3 is for inter-RAT handover from GERAN to UTRAN test cases.

Configuration 4 is applied to MBMS test cases.

Configuration 5 is applied to MBMS MBSFN test cases.

Configuration 6 is applied to the interRAT E-UTRA – UTRA test. The UTRA SIB scheduling is referred to 36.508 [45] clause 4.4.4.2.

Configuration 7 is applied to the interRAT EUTRA – UTRA – GERAN test. The UTRA SIB scheduling is referred to 36.508 [45] clause 4.4.4.3.

Configuration 8 is applied to the test cases which need a long SIB5/SIB5bis content: for example, enhanced FACH Uplink.

Configuration 9 is applied to the EAB test cases which need SIB21.

Configuration 10 is applied to test cases for Concurrent deployment of 2ms and 10ms TTI in a cell, NodeB triggered HS-DPCCH transmission, Fallback to R99 PRACH, TTI alignment, Per HARQ process activation and de-activation and HS-DSCH DRX operation with second DRX cycle in CELL_FACH which need SIB22 and long SIB5/SIB5bis.

Configuration 11 is applied to the RAN Assisted WLAN interworking test cases which need SIB23

Configuration 1 or configuration 8

MIB, SB1, SIB1, SIB2, SIB3, SIB4, SIB5/SIB5bis, SIB6, SIB7, SIB11, SIB12, SIB18

Configuration 2

MIB, SB1, SIB1, SIB2, SIB3, SIB4, SIB5/SIB5bis, SIB7, SIB11, SIB12, SIB18

Configuration 3

MIB, SB1, SIB1, SIB2, SIB3, SIB4, SIB5/SIB5bis, SIB7, SIB11, SIB16, SIB18

Configuration 4

MIB, SB1, SIB1, SIB2, SIB3, SIB4, SIB5/SIB5bis, SIB7, SIB11, SIB11bis (empty segment), SIB16, SIB18

Configuration 5

MIB, SIB3, SIB5/SIB5bis, SIB11

Configuration 6

MIB, SB1, SIB1, SIB2, SIB3, SIB4, SIB5/SIB5bis, SIB7, SIB11, SIB12, SIB18, SIB19

Configuration 7

MIB, SB1, SIB1, SIB2, SIB3, SIB4, SIB5/SIB5bis, SIB7, SIB11, SIB16, SIB18, SIB19

Configuration 9

MIB, SB1, SIB1, SIB2, SIB3, SIB4, SIB5/SIB5bis, SIB6, SIB7, SIB11, SIB12, SIB18, SIB21

Configuration 10

MIB, SB1, SIB1, SIB2, SIB3, SIB4, SIB5/SIB5bis, SIB6, SIB7, SIB11, SIB12, SIB18, SIB22

Configuration 11

MIB, SB1, SIB1, SIB2, SIB3, SIB4, SIB5/SIB5bis, SIB6, SIB7, SIB11, SIB12, SIB18,SIB23

6.1.0a.3 SIB default schedule

Block

Type

MIB

SB1

SIB1

SIB2

SIB3

SIB4

SIB5/SIB5bis

SIB6

SIB7

SIB11

SIB12

SIB18

SIB_REP

8

16

64

64

64

64

64

64

16

64

64

64

SEG_
COUNT

1

1

1

1

1

1

4

4

1

3

3

1

Frame No / SIB_POS

0

2

4

6

8

10

12

14

Block Type

MIB

SB1

SIB7

SIB6

MIB

SIB6

SIB6

SIB6

Frame No / SIB_POS

16

18

20

22

24

26

28

30

Block Type

MIB

SB1

SIB7/SIB3

SIB1/SIB2

MIB

SIB12

SIB12

SIB12

Frame No / SIB_POS

32

34

36

38

40

42

44

46

Block Type

MIB

SB1

SIB7/SIB18

SIB5/

SIB5bis

MIB

SIB5/

SIB5bis

SIB5/

SIB5bis

SIB5/

SIB5bis

Frame No / SIB_POS

48

50

52

54

56

58

60

62

Block Type

MIB

SB1

SIB7/SIB4

MIB

SIB11

SIB11

SIB11

The SEG_COUNT in the table specifies the maximum possible transport BCH blocks scheduled for broadcasting. The more contents a SIB has, the more transport BCH blocks are needed for broadcasting. In order to keep SIB repetition period, SIB_REP, unchanged in different test cases, each specific SIB in the individual test cases after the PER encoding shall not exceed the SEG_COUNT scheduled.

If the transport BCH blocks actually required for a SIB is less than the scheduled SEG_COUNT, the no_segment blocks shall be placed at the rest scheduled transport BCH blocks. In addition, the corresponding SEG_COUNT IE value in MIB or in SB1 shall be set to the number of transport BCH blocks actually required.

Contents of Master Information Block PLMN type is the case of GSM-MAP

– MIB value tag

A valid MIB value tag value as defined in TS 25.331 [34]

– Supported PLMN types

– PLMN type

GSM-MAP

– PLMN identity

– MCC digit

Set to the same Mobile Country Codes stored in the test USIM card (clause 8.3.2.2 EF IMSI(IMSI)).

– MNC digit

Set to the same Mobile Network Codes stored in the test USIM card (clause 8.3.2.2 EF IMSI(IMSI)).

– ANSI-41 Core Network information

Not Present

– References to other system information blocks and scheduling blocks

– References to other system information blocks

– Scheduling information

– CHOICE Value tag

Cell Value Tag

– Cell Value tag

A valid Cell value tag value as defined in TS 25.331 [34]

– Scheduling

– SEG_COUNT

1

– SIB_REP

16

– SIB_POS

2

– SIB_POS offset info

Not Present – use default

– SIB and SB type

Scheduling Block 1

– Scheduling information

– CHOICE Value tag

PLMN Value tag

– PLMN Value tag

A valid PLMN value tag value as defined in TS 25.331 [34]

– SEG_COUNT

1

– SIB_REP

64

– SIB_POS

22

– SIB_POS offset info

Not Present – use default

– SIB and SB type

System Information Type 1

– Scheduling information

– CHOICE Value tag

Cell Value tag

– Cell Value tag

A valid Cell value tag value as defined in TS 25.331 [34]

– SEG_COUNT

1

– SIB_REP

64

– SIB_POS

22

– SIB_POS offset info

Not Present – use default

– SIB and SB type

System Information Type 2

– Scheduling information

– CHOICE Value tag

Cell Value tag

– Cell Value tag

1

– SEG_COUNT

1

– SIB_REP

64

– SIB_POS

20

– SIB_POS offset info

Not Present – use default

– SIB and SB type

System Information Type 3

– Scheduling information

– CHOICE Value tag

Cell Value tag

– Cell Value tag

A valid Cell value tag value as defined in TS 25.331 [34]

– SEG_COUNT

1

– SIB_REP

64

– SIB_POS

52

– SIB_POS offset info

Not Present – use default

– SIB and SB type

System Information Type 4

– Scheduling information

– CHOICE Value tag

Cell Value tag

– Cell Value tag

A valid Cell value tag value as defined in TS 25.331 [34]

– SEG_COUNT

4

– SIB_REP

64

– SIB_POS

38

– SIB_POS offset info

– SIB_OFF

4

– SIB_OFF

2

– SIB_OFF

2

– SIB and SB type

System Information Type 5 / System Information Type 5bis

– CSG Indicator

Not Present

NOTE: System Information Type 5 or System Information Type 5bis are used dependent on the frequency band variant used by the SS.

Contents of Scheduling Block 1 (FDD and 1.28 Mcps TDD)

– References to other system information blocks

– Scheduling information

– CHOICE Value tag

Cell Value tag

– Cell Value tag

A valid Cell value tag value as defined in TS 25.331 [34]

– SEG_COUNT

4

– SIB_REP

64

– SIB_POS

6

– SIB_POS offset info

– SIB_OFF

4

– SIB_OFF

2

– SIB_OFF

2

– SIB type SIBs only

System Information Type 6

– Scheduling information

– CHOICE Value tag

Not Present

– SEG_COUNT

1

– SIB_REP

16

– SIB_POS

4

– SIB_POS offset info

Not Present

– SIB type SIBs only

System Information Type 7

– Scheduling information

– CHOICE Value tag

Cell Value tag

– Cell Value tag

A valid Cell value tag value as defined in TS 25.331 [34]

– SEG_COUNT

3

– SIB_REP

64

– SIB_POS

58

– SIB_POS offset info

– SIB_OFF

2

– SIB_OFF

2

– SIB type SIBs only

System Information Type 11

– Scheduling information

– CHOICE Value tag

Cell Value tag

– Cell Value tag

A valid Cell value tag value as defined in TS 25.331 [34]

– SEG_COUNT

3

– SIB_REP

64

– SIB_POS

26

– SIB_POS offset info

– SIB_OFF

2

– SIB_OFF

2

– SIB type SIBs only

System Information Type 12

– Scheduling information

– CHOICE Value tag

Cell Value tag

Cell Value tag

A valid Cell value tag value as defined in TS 25.331 [34]

– SEG_COUNT

1

– SIB_REP

64

– SIB_POS

36

– SIB_POS offset info

Not Present

– SIB type SIBs only

System Information Type 18

Contents of Scheduling Block 1 (3.84 Mcps TDD and 7.68 Mcps TDD)

– References to other system information blocks

– Scheduling information

– CHOICE Value tag

Cell Value tag

– Cell Value tag

A valid Cell value tag value as defined in TS 25.331 [34]

– SEG_COUNT

4

– SIB_REP

128

– SIB_POS

3

– SIB_POS offset info

– SIB_OFF

4

– SIB_OFF

2

– SIB_OFF

2

– SIB type SIBs only

System Information Type 6

– Scheduling information

– CHOICE Value tag

Not Present

– SEG_COUNT

1

– SIB_REP

16

– SIB_POS

2

– SIB_POS offset info

Not Present

– SIB type SIBs only

System Information Type 7

– Scheduling information

– CHOICE Value tag

Cell Value tag

– Cell Value tag

A valid Cell value tag value as defined in TS 25.331 [34]

– SEG_COUNT

3

– SIB_REP

64

– SIB_POS

29

– SIB_POS offset info

– SIB_OFF

2

– SIB_OFF

2

– SIB type SIBs only

System Information Type 11

– Scheduling information

– CHOICE Value tag

Cell Value tag

– Cell Value tag

A valid Cell value tag value as defined in TS 25.331 [34]

– SEG_COUNT

3

– SIB_REP

64

– SIB_POS

13

– SIB_POS offset info

– SIB_OFF

2

– SIB_OFF

2

– SIB type SIBs only

System Information Type 12

– Scheduling information

– CHOICE Value tag

Not Present

– SEG_COUNT

1

– SIB_REP

64

– SIB_POS

54

– SIB_POS offset info

Not Present – use default

– SIB type SIBs only

System Information Type 14

– Scheduling information

– CHOICE Value tag

PLMN Value tag

– PLMN Value tag

A valid PLMN value tag value as defined in TS 25.331 [34]

– SEG_COUNT

1

– SIB_REP

64

– SIB_POS

6

– SIB_POS offset info

Not Present

– SIB type SIBs only

System Information Type 18

6.1.0a.4 SIB special schedules

6.1.0a.4.1 SIB schedule for two S-CCPCH or two PRACH (For FDD and 1.28Mcps TDD)

Table 1

Frame No.

0

2

4

6

8

10

12

14

REP-POS

0

1

2

3

4

5

6

7

Block Type

MIB

SB1

SB1

MIB

SIB1

SIB18

SIB2

Frame No.

16

18

20

22

24

26

28

30

REP-POS

8

9

10

11

12

13

14

15

Block Type

MIB

SB1

SB1

SIB7

MIB

SIB3

SIB4

Frame No.

32

34

36

38

40

42

44

46

REP-POS

16

17

18

19

20

21

22

23

Block Type

MIB

SB1

SB1

SIB5/

SIB5bis

MIB

SIB5/

SIB5bis

SIB5/

SIB5bis

SIB5/

SIB5bis

Frame No.

48

50

52

54

56

58

60

62

REP-POS

24

25

26

27

28

29

30

31

Block Type

MIB

SB1

SB1

SIB7

MIB

SIB11

SIB11

SIB11

Frame No.

64

66

68

70

72

74

76

78

REP-POS

32

33

34

35

36

37

38

39

Block Type

MIB

SB1

SB1

SIB5/

SIB5bis

MIB

SIB5/

SIB5bis

SIB5/

SIB5bis

SIB5/

SIB5bis

Frame No.

80

82

84

86

88

90

92

94

REP-POS

40

41

42

43

44

45

46

47

Block Type

MIB

SB1

SB1

SIB7

MIB

SIB3

SIB4

Frame No.

96

98

100

102

104

106

108

110

REP-POS

48

49

50

51

52

53

54

55

Block Type

MIB

SB1

SB1

MIB

Frame No.

112

114

116

118

120

122

124

126

REP-POS

56

57

58

59

60

61

62

63

Block Type

MIB

SB1

SB1

SIB7

MIB

SIB12

SIB12

SIB12

SIB-repeat period (in frame)

Table 2

Block Type

MIB

SB1

SIB1

SIB2

SIB3

SIB4

SIB5/

SIB5bis

SIB7

SIB11

SIB12

SIB18

SIB Rep

8

16

128

128

64

64

128

32

128

128

128

Max. No of seg.

1

2

1

1

1

1

8

1

3

3

1

6.1.0a.4.2 SIB schedule for Idle Mode, Measurement and Inter RAT UTRAN to GERAN test cases

Frame No.

0

2

4

6

8

10

12

14

REP-POS

0

1

2

3

4

5

6

7

Block Type

MIB

SB1

SIB6

SIB6

MIB

SIB6

SIB6

SIB7/

SIB3

Frame No.

16

18

20

22

24

26

28

30

REP-POS

8

9

10

11

12

13

14

15

Block Type

MIB

SB1

SIB1/SIB2

SIB12

MIB

SIB12

SIB12

SIB7/

SIB12

Frame No.

32

34

36

38

40

42

44

46

REP-POS

16

17

18

19

20

21

22

23

Block Type

MIB

SB1

SIB5/

SIB5bis

SIB5/

SIB5bis

MIB

SIB5/

SIB5bis

SIB5/

SIB5bis

SIB7/

SIB18

Frame No.

48

50

52

54

56

58

60

62

REP-POS

24

25

26

27

28

29

30

31

Block Type

MIB

SB1

SIB11

SIB11

MIB

SIB11

SIB11

SIB7/SIB4

SIB-repeat period (in frame)

Block

Type

MIB

SB1

SIB1

SIB2

SIB3

SIB4

SIB5/

SIB5bis

SIB6

SIB7

SIB11

SIB12

SIB18

SIB Rep

8

16

64

64

64

64

64

64

16

64

64

64

Max. No of seg.

1

1

1

1

1

1

4

4

1

4

4

1

6.1.0a.4.3 SIB schedule for Inter RAT handover GERAN to UTRAN test cases

Frame No.

0

2

4

6

8

10

12

14

REP-POS

0

1

2

3

4

5

6

7

Block Type

MIB

SB1

SB1

MIB

SIB1

SIB18

SIB2

Frame No.

16

18

20

22

24

26

28

30

REP-POS

8

9

10

11

12

13

14

15

Block Type

MIB

SB1

SB1

SIB7

MIB

SIB3

SIB4

Frame No.

32

34

36

38

40

42

44

46

REP-POS

16

17

18

19

20

21

22

23

Block Type

MIB

SB1

SB1

SIB5/

SIB5bis

MIB

SIB5/

SIB5bis

SIB5/

SIB5bis

SIB5/

SIB5bis

Frame No.

48

50

52

54

56

58

60

62

REP-POS

24

25

26

27

28

29

30

31

Block Type

MIB

SB1

SB1

SIB7

MIB

SIB11

SIB11

SIB11

Frame No.

64

66

68

70

72

74

76

78

REP-POS

32

33

34

35

36

37

38

39

Block Type

MIB

SB1

SB1

SIB16

MIB

SIB16

SIB16

SIB16

Frame No.

80

82

84

86

88

90

92

94

REP-POS

40

41

42

43

44

45

46

47

Block Type

MIB

SB1

SB1

SIB7

MIB

SIB3

SIB4

Frame No.

96

98

100

102

104

106

108

110

REP-POS

48

49

50

51

52

53

54

55

Block Type

MIB

SB1

SB1

SIB16

MIB

SIB16

SIB16

SIB16

Frame No.

112

114

116

118

120

122

124

126

REP-POS

56

57

58

59

60

61

62

63

Block Type

MIB

SB1

SB1

SIB7

MIB

SIB-repeat period (in frame)

Block

Type

MIB

SB1

SIB1

SIB2

SIB3

SIB4

SIB5/

SIB5bis

SIB7

SIB11

SIB16

SIB18

SIB Rep

8

16

128

128

64

64

128

32

128

128

128

Max. No of seg.

1

2

1

1

1

1

4

1

3

8

1

6.1.0a.4.4 SIB schedule for MBMS test cases

Table 3

Frame No.

0

2

4

6

8

10

12

14

REP-POS

0

1

2

3

4

5

6

7

Block Type

MIB

SB1

SB1

SIB6

MIB

SIB1

SIB18

SIB2

Frame No.

16

18

20

22

24

26

28

30

REP-POS

8

9

10

11

12

13

14

15

Block Type

MIB

SB1

SB1

SIB7

MIB

SIB3

SIB6

SIB4

Frame No.

32

34

36

38

40

42

44

46

REP-POS

16

17

18

19

20

21

22

23

Block Type

MIB

SB1

SB1

SIB5/

SIB5bis

MIB

SIB5/

SIB5bis

SIB5/

SIB5bis

SIB5/

SIB5bis

Frame No.

48

50

52

54

56

58

60

62

REP-POS

24

25

26

27

28

29

30

31

Block Type

MIB

SB1

SB1

SIB7

MIB

SIB5/

SIB5bis

SIB5/

SIB5bis

SIB5/

SIB5bis

Frame No.

64

66

68

70

72

74

76

78

REP-POS

32

33

34

35

36

37

38

39

Block Type

MIB

SB1

SB1

SIB11

MIB

SIB11

SIB11

SIB11

Frame No.

80

82

84

86

88

90

92

94

REP-POS

40

41

42

43

44

45

46

47

Block Type

MIB

SB1

SB1

SIB7

MIB

SIB11

SIB11

SIB11

Frame No.

96

98

100

102

104

106

108

110

REP-POS

48

49

50

51

52

53

54

55

Block Type

MIB

SB1

SB1

SIB12

MIB

SIB12

Frame No.

112

114

116

118

120

122

124

126

REP-POS

56

57

58

59

60

61

62

63

Block Type

MIB

SB1

SB1

SIB7

MIB

SIB11bis

SIB11bis

SIB11bis

SIB-repeat period (in frame)

Table 4

Block

Type

MIB

SB1

SIB1

SIB2

SIB3

SIB4

SIB5/

SIB5bis

SIB6

SIB7

SIB11

SIB11bis

SIB12

SIB18

SIB Rep

8

16

128

128

128

128

128

128

32

128

128

128

128

Max. No of seg.

1

2

1

1

1

1

7

2

1

7

3

2

1

6.1.0a.4.5 SIB schedule for MBMS MBSFN test cases
Contents of Master Information Block in the case where PLMN type is GSM-MAP

– MIB value tag

A valid MIB value tag value as defined in TS 25.331 [34]

– Supported PLMN types

– PLMN type

GSM-MAP

– PLMN identity

– MCC digit

Set to the same Mobile Country Codes stored in the test USIM card (clause 8.3.2.2 EF IMSI(IMSI)).

– MNC digit

Set to the same Mobile Network Codes stored in the test USIM card (clause 8.3.2.2 EF IMSI(IMSI)).

– ANSI-41 Core Network information

Not Present

– References to other system information blocks and scheduling blocks

– References to other system information blocks

– Scheduling information

– CHOICE Value tag

Cell Value Tag

– Cell Value tag

A valid Cell value tag value as defined in TS 25.331 [34]

– Scheduling

– SEG_COUNT

1

– SIB_REP

16

– SIB_POS

2

– SIB_POS offset info

Not Present – use default

– SIB and SB type

System Information Type 3

– Scheduling information

– CHOICE Value tag

Cell Value Tag

– Cell Value tag

A valid Cell value tag value as defined in TS 25.331 [34]

– Scheduling

– SEG_COUNT

2

– SIB_REP

16

– SIB_POS

4

– SIB_POS offset info

Not Present – use default

– SIB and SB type

System Information Type 5

– Scheduling information

– CHOICE Value tag

Cell Value tag

– Cell Value tag

A valid Cell value tag value as defined in TS 25.331 [34]

– Scheduling

– SEG_COUNT

2

– SIB_REP

16

– SIB_POS

10

– SIB_POS offset info

Not Present – use default

– SIB and SB type

System Information Type 11

SIB schedule

Frame No / SIB_POS

0

2

4

6

8

10

12

14

Block Type

MIB

SIB3

SIB5

SIB5

SIB11

SIB11

SIB11

SIB-repeat period (in frame)

Block Type

MIB

SIB3

SIB5

SIB11

SIB Rep

16

16

16

16

Max. No of seg.

1

1

2

3

6.1.0a.4.6 SIB default schedule for long SIB5/SIB5bis

Block

Type

MIB

SB1

SIB1

SIB2

SIB3

SIB4

SIB5/SIB5bis

SIB6

SIB7

SIB11

SIB12

SIB18

SIB_REP

8

16

64

64

64

64

64

64

16

64

64

64

SEG_
COUNT

1

1

1

1

1

1

6

4

1

3

2

1

Frame No / SIB_POS

0

2

4

6

8

10

12

14

Block Type

MIB

SB1

SIB7

SIB6

MIB

SIB6

SIB6

SIB6

Frame No / SIB_POS

16

18

20

22

24

26

28

30

Block Type

MIB

SB1

SIB7/SIB3

SIB1/SIB2

MIB

SIB12

SIB12

SIB5/SIB5bis

Frame No / SIB_POS

32

34

36

38

40

42

44

46

Block Type

MIB

SB1

SIB7/SIB18

SIB5/

SIB5bis

MIB

SIB5/

SIB5bis

SIB5/

SIB5bis

SIB5/

SIB5bis

Frame No / SIB_POS

48

50

52

54

56

58

60

62

Block Type

MIB

SB1

SIB7/SIB4

SIB5/SIB5bis

MIB

SIB11

SIB11

SIB11

6.1.0a.4.7 SIB schedule for EAB test cases

Block

Type

MIB

SB1

SIB1

SIB2

SIB3

SIB4

SIB5/SIB5bis

SIB6

SIB7

SIB11

SIB12

SIB18

SIB21

SIB_REP

8

16

64

64

64

64

64

64

16

64

64

64

64

SEG_
COUNT

1

1

1

1

1

1

4

4

1

3

3

1

1

Frame No / SIB_POS

0

2

4

6

8

10

12

14

Block Type

MIB

SB1

SIB7

SIB6

MIB

SIB6

SIB6

SIB6

Frame No / SIB_POS

16

18

20

22

24

26

28

30

Block Type

MIB

SB1

SIB7/SIB3

SIB1/SIB2

MIB

SIB12

SIB12

SIB12

Frame No / SIB_POS

32

34

36

38

40

42

44

46

Block Type

MIB

SB1

SIB7/SIB18

SIB5/

SIB5bis

MIB

SIB5/

SIB5bis

SIB5/

SIB5bis

SIB5/

SIB5bis

Frame No / SIB_POS

48

50

52

54

56

58

60

62

Block Type

MIB

SB1

SIB7/SIB4

SIB21

MIB

SIB11

SIB11

SIB11

6.1.0a.4.8 SIB schedule for test cases that require SIB22

Block

Type

MIB

SB1

SIB1

SIB2

SIB3

SIB4

SIB5/SIB5bis

SIB6

SIB7

SIB11

SIB12

SIB18

SIB22

SIB_REP

8

16

64

64

64

64

64

64

16

64

64

64

64

SEG_
COUNT

1

1

1

1

1

1

6

4

1

3

1

1

1

Frame No / SIB_POS

0

2

4

6

8

10

12

14

Block Type

MIB

SB1

SIB7

SIB6

MIB

SIB6

SIB6

SIB6

Frame No / SIB_POS

16

18

20

22

24

26

28

30

Block Type

MIB

SB1

SIB7/SIB3

SIB1/SIB2

MIB

SIB12

SIB5/SIB5bis

SIB5/SIB5bis

Frame No / SIB_POS

32

34

36

38

40

42

44

46

Block Type

MIB

SB1

SIB7/SIB18

SIB5/

SIB5bis

MIB

SIB5/

SIB5bis

SIB5/

SIB5bis

SIB5/

SIB5bis

Frame No / SIB_POS

48

50

52

54

56

58

60

62

Block Type

MIB

SB1

SIB7/SIB4

SIB22

MIB

SIB11

SIB11

SIB11

6.1.0a.4.9 SIB schedule for RAN Assisted WLAN interworking test cases

Block

Type

MIB

SB1

SIB1

SIB2

SIB3

SIB4

SIB5/SIB5bis

SIB6

SIB7

SIB11

SIB12

SIB18

SIB23

SIB_REP

8

16

64

64

64

64

64

64

16

64

64

64

64

SEG_
COUNT

1

1

1

1

1

1

6

4

1

3

1

1

1

Frame No / SIB_POS

0

2

4

6

8

10

12

14

Block Type

MIB

SB1

SIB7

SIB6

MIB

SIB6

SIB6

SIB6

Frame No / SIB_POS

16

18

20

22

24

26

28

30

Block Type

MIB

SB1

SIB7/SIB3

SIB1/SIB2

MIB

SIB12

SIB5/SIB5bis

SIB5/SIB5bis

Frame No / SIB_POS

32

34

36

38

40

42

44

46

Block Type

MIB

SB1

SIB7/SIB18

SIB5/

SIB5bis

MIB

SIB5/

SIB5bis

SIB5/

SIB5bis

SIB5/

SIB5bis

Frame No / SIB_POS

48

50

52

54

56

58

60

62

Block Type

MIB

SB1

SIB7/SIB4

SIB23

MIB

SIB11

SIB11

SIB11