C.3 Data description for 5G data connectivity charging
32.2553GPP5G data connectivity domain chargingCharging managementRelease 17Stage 2Telecommunication managementTS
C.3.1 Data description for support of GERAN/UTRAN access
C.3.1.1 Message contents
The charging message as described in clause 6.1.1 shall apply to the SMF+PGW-C to support GERAN/UTRAN access. The differences of charging message in clause 6.1.1 used for the SMF+PGW-C to support GERAN/UTRAN access are described as following.
– UPF ID is not applicable;
– Multi-homed PDU address is not applicable;
– PDU Session Charging Information is described in C.3.2.
C.3.1.2 Ga message contents
The Ga message transfer as described in clause 5.2.4 shall apply to the SMF+PGW-C to support GERAN/UTRAN access.
C.3.1.3 CDR description on the Bd interface
The CDR description defined in clause 6.1.3 shall apply with the differences that SMF is replaced by SMF+PGW-C supporting GERAN/UTRAN access, and the following fields in table 6.1.3.2.1 are not applicable:
– UPF ID;
– Multi-homed PDU address.
C.3.2 5G data connectivity charging specific parameters
C.3.2.1 Definition of 5G data connectivity charging information
The charging information defined in clause 6.2.1 is used for the SMF+PGW-C to support GERAN/UTRAN access.
The specific PDU session charging information when UE is connected to SMF+P-GW-C via GERAN/UTRAN is provided as defined in table 6.2.1.2.1, with the differences that PDU session is replaced by PDP context in fields description and other differences described under following table C.3.2.1-1:
Table C.3.2.1-1: Structure of PDU Session Charging Information
Information Element |
Category |
Description |
Charging Id |
OM |
Described in table 6.2.1.2. |
Home Provided Charging Id |
– |
This field is not applicable. |
User Information |
OM |
Described in table 6.2.1.2. |
User Identifier |
OC |
Described in table 6.2.1.2. |
User Equipment Info |
OC |
Described in table 6.2.1.2. |
unauthenticatedFlag |
OC |
Described in table 6.2.1.2. |
Roamer In Out |
OC |
Described in table 6.2.1.2. |
User Location Info |
OC |
Described in table 6.2.1.2. The "User Location Information" (ULI) IE indicating CGI/SAI/RAI shall apply as described in clause 7.7.51 of TS 29.060 [x]. |
MA PDU Non 3GPP User Location info |
– |
This field is not applicable. |
User Location Time |
OC |
Described in table 6.2.1.2. |
MA PDU Non 3GPP User Location Time |
– |
This field is not applicable. |
UE Time Zone |
OC |
Described in table 6.2.1.2. |
Presence Reporting Area Information |
OC |
This field is not applicable.. |
PDU Session Information |
OC |
Described in table 6.2.1.2. |
PDU Session ID |
M |
Described in table 6.2.1.2. |
Network Slice Instance Identifier |
– |
This field is not applicable. |
PDU Type |
OM |
Described in table 6.2.1.2. |
PDU Address |
OC |
Described in table 6.2.1.2. |
PDU Ipv4 Address |
OC |
Described in table 6.2.1.2. |
PDU IPv6 Address with Prefix |
OC |
Described in table 6.2.1.2. |
PDU Address prefix length |
OC |
Described in table 6.2.1.2. |
IPv4 Dynamic Address Flag |
OC |
Described in table 6.2.1.2. |
IPv6 Dynamic Address Flag |
OC |
Described in table 6.2.1.2. |
SSC Mode |
– |
This field is not applicable. |
MA PDU session information |
– |
This field is not applicable. |
MA PDU session indicator |
– |
This field is not applicable. |
ATSSS capability |
– |
This field is not applicable. |
SUPI PLMN ID |
OC– |
Described in table 6.2.1.2. |
Serving Network Function ID |
OC |
Described in table 6.2.1.2. |
Serving Network Function Functionality |
M |
Described in table 6.2.1.2. This field holds “SGSN” when SMF+PGW-C serves GERAN/UTRAN access. |
Serving Network Function Name |
– |
Described in table 6.2.1.2. |
Serving Network Function Addresses |
OC |
Described in table 6.2.1.2. |
Serving Network Function FQDN |
OC |
Described in table 6.2.1.2. |
Serving Network Function PLMN ID |
OC |
Described in table 6.2.1.2. |
AMF Identifier |
– |
This field is not applicable. |
Serving CN PLMN ID |
OC |
Described in table 6.2.1.2. |
RAT Type |
OC |
Described in table 6.2.1.2. |
MA PDU Non 3GPP RAT Type |
– |
This field is not applicable. |
Data Network Name Identifier |
M |
Described in table 6.2.1.2, with DNN replaced by APN. |
DNN Selection Mode |
– |
This field is not applicable. |
Authorized QoS Information |
OC |
Described in table 6.2.1.2 QoS information mapped according interaction with PCC as specified in clause 4.11.0a.2 of TS 23.502 [201] |
Subscribed QoS Information |
OC |
Described in table 6.2.1.2 QoS information mapped according interaction with PCC as specified in clause 4.11.0a.2 of TS 23.502 [201]. |
Authorized Session-AMBR |
OC |
Described in table 6.2.1.2. |
Subscribed Session-AMBR |
OC |
Described in table 6.2.1.2. |
PDU session start Time |
OC |
Described in table 6.2.1.2. |
PDU session stop Time |
OC |
Described in table 6.2.1.2. |
Diagnostics |
OC |
Described in table 6.2.1.2. |
Enhanced Diagnostics |
OC |
Described in table 6.2.1.2. |
Charging Characteristics |
OC |
Described in table 6.2.1.2. |
Charging Characteristics Selection Mode |
OC |
Described in table 6.2.1.2. |
3GPP PS Data Off Status |
OC |
Described in table 6.2.1.2. |
Session Stop Indicator |
– |
This field is not applicable. |
Redundant Transmission Type |
– |
This field is not applicable. |
PDU Session pair ID |
– |
This field is not applicable. |
Unit Count Inactivity Timer |
– |
This field is not applicable. |
RAN Secondary RAT Usage Report |
– |
This field is not applicable. |
The specific PDU Container Information when UE is connected to SMF+P-GW-C via GERAN/UTRAN is provided as defined in table 6.2.1.3.1, with the differences described under following table C.3.2.1-2:
Table C.3.2.1-2: Structure of PDU Container Information
Information Element |
Category |
Description |
---|---|---|
Time of First Usage |
OC |
Described in table 6.2.1.3.1. |
Time of Last Usage |
OC |
Described in table 6.2.1.3.1. |
QoS Information |
OC |
Described in table 6.2.1.3.1. |
QoS Characteristics |
OC |
Described in table 6.2.1.3.1. |
AF Charging Identifier |
OC |
Described in table 6.2.1.3.1. |
AF Charging Id String |
OC |
Described in table 6.2.1.3.1. |
User Location Information |
OC |
Described in table 6.2.1.3.1. |
UE Time Zone |
OC |
Described in table 6.2.1.3.1. |
Presence Reporting Area Information |
OC |
Described in table 6.2.1.3.1. |
Serving Network Function ID |
OC |
Described in table 6.2.1.3.1. |
RAT Type |
OC |
Described in table 6.2.1.3.1. |
Sponsor Identity |
OC |
Described in table 6.2.1.3.1. |
Application Service Provider Identity |
OC |
Described in table 6.2.1.3.1. |
Charging Rule Base Name |
OC |
Described in table 6.2.1.3.1. |
3GPP PS Data Off Status |
OC |
Described in table 6.2.1.3.1. |
MA PDU Steering functionality |
– |
This field is not applicable. |
MA PDU Steering mode |
– |
This field is not applicable. |
The specific Roaming QBC information is described in table B.2.2.1.2-1 and QFI Container Information is described in table B.2.2.1.3-1 for when UE is connected to SMF+P-GW via GERAN/UTRAN, with the differences that PDU session is replaced by PDP context in fields description.
C.3.2.2 Detailed message format for converged charging
The basic structure of supported fields in Charging Data Request/Response message defined in clause 6.2.2 shall apply for fields applicable when SMF+PGW-C supports GERAN/UTRAN access.
C.3.2.3 Formal 5G data connectivity charging parameter description
TheCHF CDR parameters and resources attributes defined in clause 6.2.3 shall apply for fields applicable when SMF+PGW-C supports GERAN/UTRAN access.
Annex D (informative):
Network slice charging based on 5G data connectivity