27.22.2A Definition of default values for USIM Application Toolkit testing

31.1243GPPMobile Equipment (ME) conformance test specificationRelease 16TSUniversal Subscriber Identity Module Application Toolkit (USAT) conformance test specification

A UICC containing the following default values is used for all tests of this clause unless otherwise stated.

For each item, the logical default values and the coding within the Elementary Files (EF) of the USIM follow, as defined in:

– TS 31.121 [21], clause 4.1.

– ETSI TS 102 384 [26], clause 27.22.1B.

Note 1: Bx represents byte x of the coding.

Note 2: Unless otherwise defined, the coding values in binary.

EFUST (USIM Service Table)

Logically:

Service n°1:

Local Phone Book

available

Service n°2:

Fixed Dialling Numbers (FDN)

available

Service n°6:

Barred Dialling Numbers (BDN)

available

Service n°10:

Short Message Storage (SMS)

available

Service n°11:

Short Message Status Reports (SMSR)

available

Service n°12:

Short Message Service Parameters (SMSP)

available

Service n°15:

Cell Broadcast Message Identifier

available

Service n°17:

Group Identifier Level 1

not available

Service n°18:

Group Identifier Level 2

not available

Service n°20:

User controlled PLMN selector with Access Technology

available

Service n°22:

Image (IMG)

available

Service n°27:

GSM Access

available

Service n°28:

Data download via SMS-PP

available

Service n°29:

Data download via SMS‑CB

available

Service n°30:

Call Control by USIM

not available

Service n°31:

MO-SMS Control by USIM

not available

Service n°32:

RUN AT COMMAND command

available

Service n°33:

shall be set to ‘1’

available

Service n°34:

Enabled Services Table

available

Service n°85

EPS Mobility Management Information

not available

Service n°86

Allowed CSG Lists and corresponding indications

not available

Byte:

B1

B2

B3

B4

B5

B6

binary

xx1x xx11

x1xx 111x

xx1x 1×00

1001 11xx

xxx xx11

xxxx xxxx

B7

B8

B9

B10

B11

xxxx xxxx

xxxx xxxx

xxxx xxxx

xxxx xxxx

xx00 xxxx

The coding of EFUST shall conform with the capabilities of the USIM used.

EFEST (Enabled Services Table)

Logically:

Service n°1:

Fixed Dialling Numbers (FDN)

Service n°2:

Barred Dialling Numbers (BDN)

Service n°3:

APN Control List (ACL)

Byte:

B1

Coding

00

EFIMSI (International Mobile Subscriber Identity)

Logically:

Length: 8 bytes

IMSI: 001 01 0123456789

Coding:

’08 09 10 10 10 32 54 76 98′

EFAD (Administrative Data)

Logically: Type approval operations

OFM to be deactivated by the Terminal

MNC: 2 digit

Coding:

B1

B2

B3

B4

Hex

80

00

00

02

EFLOCI (Location Information)

Logically:

LAI-MCC: 001

LAI-MNC: 01

LAI-LAC: 0001

TMSI: "FF .. FF"

Coding:

B1

B2

B3

B4

B5

B6

B7

B8

B9

B10

B11

Hex

FF

FF

FF

FF

00

F1

10

00

01

FF

00

EFPSLOCI (Packet Switch Location Information)

Logically:

RAI-MCC: 001

RAI-MNC: 01

RAI-LAC: 0001

RAI-RAC: 05

P-TMSI: "FF….FF"

P-TMSI signature value: "FF…FF"

Coding:

B1

B2

B3

B4

B5

B6

B7

Hex

FF

FF

FF

FF

FF

FF

FF

Coding:

B8

B9

B10

B11

B12

B13

B14

Hex

00

F1

10

00

01

05

00

EFCBMI (Cell Broadcast Message Identifier)

Logically:

Cell Broadcast Message Identifier 1: ’03 E7′

Coding:

03

E7

FF

..

FF

EFCBMID (Cell Broadcast Message Identifier for Data Download)

Logically:

Cell Broadcast Message Identifier 1: ’10 01′

Coding:

10

01

FF

..

FF

EFFDN (Fixed Dialling Numbers)

Logically:

Record 1: Length of alp ha identifier: 6 characters;

Alpha identifier: "FDN111";

Length of BCD number: "03";

TON and NPI: Telephony and unknown;

Dialled number: 123;

CCI: None;

Ext2: None.

Coding for record 1:

B1

B2

B3

B4

B5

B6

B7

B8

B9

B10

B11

B12

B13

Hex

46

44

4E

31

31

31

03

81

21

F3

FF

FF

FF

B14

B15

B16

B17

B18

B19

B20

FF

FF

FF

FF

FF

FF

FF

Record 2: Length of alpha identifier: 6 characters;

Alpha identifier: "FDN222";

Length of BCD number: "03";

TON and NPI: Telephony and Unknown;

Dialled number: 9876;

CCI: None;

Ext2: None.

Coding for record 2:

B1

B2

B3

B4

B5

B6

B7

B8

B9

B10

B11

B12

B13

Hex

46

44

4E

32

32

32

03

81

89

67

FF

FF

FF

B14

B15

B16

B17

B18

B19

B20

FF

FF

FF

FF

FF

FF

FF

Record 3: Length of alpha identifier: 6 characters;

Alpha identifier: "FDN333";

Length of BCD number: "0B";

TON and NPI: Telephony and International;

Dialled number: +12345678901234567890;

CCI: None;

Ext2: None.

Coding for record 3:

B1

B2

B3

B4

B5

B6

B7

B8

B9

B10

B11

B12

B13

Hex

46

44

4E

33

33

33

0B

91

21

43

65

87

09

B14

B15

B16

B17

B18

B19

B20

21

43

65

87

09

FF

FF

EFBDN (Barred Dialling Numbers)

Logically:

Record 1: Length of alpha identifier: 6 characters;

Alpha identifier: "BDN111";

Length of BCD number: "06";

TON and NPI: Telephony and International;

Dialled number: +1357924680;

CCI: None;

Ext4: None

Comprehension method pointer: None.

Coding for record 1:

B1

B2

B3

B4

B5

B6

B7

B8

B9

B10

B11

B12

B13

Hex

42

44

4E

31

31

31

06

91

31

75

29

64

08

B14

B15

B16

B17

B18

B19

B20

B21

FF

FF

FF

FF

FF

FF

FF

FF

Record 2: Length of alpha identifier: 6 characters;

Alpha identifier: "BDN222";

Length of BCD number: "03";

TON and NPI: Telephony and Unknown;

Dialled number: 122;

CCI: None;

Ext4: None

Comprehension method pointer: None.

Coding for record 2:

B1

B2

B3

B4

B5

B6

B7

B8

B9

B10

B11

B12

B13

Hex

42

44

4E

32

32

32

04

81

21

F2

FF

FF

FF

B14

B15

B16

B17

B18

B19

B20

B21

FF

FF

FF

FF

FF

FF

FF

FF

Record 3: Length of alpha identifier: 6 characters;

Alpha identifier: "BDN333";

Length of BCD number: "03";

TON and NPI: Telephony and Unknown;

Dialled number: 112;

CCI: None;

Ext4: None.

Comprehension method pointer: None

Coding for record 3:

B1

B2

B3

B4

B5

B6

B7

B8

B9

B10

B11

B12

B13

Hex

42

44

4E

33

33

33

03

81

11

F2

FF

FF

FF

B14

B15

B16

B17

B18

B19

B20

B21

FF

FF

FF

FF

FF

FF

FF

FF

EFECC (Emergency Call Codes)

Logically: Emergency call code: "122";

Emergency call code alpha identifier: "TEST";

Emergency call Service Category: RFU

Coding:

B1

B2

B3

B4

B5

B6

B7

B8

Hex

21

F2

FF

54

45

53

54

00

EFSMSS (SMS Status)

Logically: Last used TP-MR set to"00".

Memory capacity available (flag unset b1="1").

Coding:

B1

B2

Hex

00

FF

EFSMSP (Short message service parameters)

Logically:

Record 1:

Record length: 28 bytes

Parameter Indicators:

TP-Destination Address: Parameter absent

TS-Service Centre Address: Parameter present

TP-Protocol Identifier: Parameter absent

TP-Data Coding Scheme: Parameter absent

TP-Validity Period: Parameter absent

TS-Service Centre Address:

TON: International Number

NPI: "ISDN / telephone numbering plan"

Dialled number string: "112233445566778"

Coding:

B1

B2

B3

B13

B14

B15

B16

B17

B18

B19

B20

B21

B22

B23

Record 1:

FD

FF

FF

FF

09

91

11

22

33

44

55

66

77

F8

B24

B25

B26

B27

B28

FF

FF

FF

FF

FF

For the display of icon: See ETSI TS 102 384 [26] clause 27.22.1B.