7.4.8 Electrical interface UE receiving

26.1313GPPRelease 18RequirementsTerminal acoustic characteristics for telephonyTS

The sensitivity/frequency characteristics shall be as follows:

The receiving sensitivity frequency response measured at the electrical reference point shall be within a mask, which can be drawn with straight lines between the breaking points in table 30a2 on a logarithmic (frequency) – linear (dB sensitivity) scale.

Table 30a2: Handset receiving sensitivity/frequency requirement mask

Frequency (Hz)

Upper limit

Lower limit

100

2

-10

200

2

-7

1000

2

-2

3000

2

–2

5000

2

–2

8000

2

-3

12500

2

-6

16000

2

NOTE: All sensitivity values are expressed in dB on an arbitrary scale.

Figure 16b: Electrical interface sensitivity/frequency masks. The frequency response of the EVS codec operating as specified in TS 26.132 (super-wideband 24,4kbit/s, using the specified P.501 speech test signal), is plotted for reference, normalized to 0dB at 1kHz.

A UE operating in super-wideband mode shall pass the super-wideband requirements (i.e. when measured according to in 1/3rd octaves) as specified in Table 30a2, and shall also pass the wideband sensitivity/frequency characteristics requirements in the wideband range using the wideband measurement (i.e. measured in 1/12th octaves) as specified in Table 14a2.

Compliance shall be checked by the relevant test described in TS 26.132.