7.4.8 Electrical interface UE receiving
26.1313GPPRelease 18RequirementsTerminal acoustic characteristics for telephonyTS
The sensitivity/frequency characteristics shall be as follows:
The receiving sensitivity frequency response measured at the electrical reference point shall be within a mask, which can be drawn with straight lines between the breaking points in table 30a2 on a logarithmic (frequency) – linear (dB sensitivity) scale.
Table 30a2: Handset receiving sensitivity/frequency requirement mask
Frequency (Hz) |
Upper limit |
Lower limit |
100 |
2 |
-10 |
200 |
2 |
-7 |
1000 |
2 |
-2 |
3000 |
2 |
–2 |
5000 |
2 |
–2 |
8000 |
2 |
-3 |
12500 |
2 |
-6 |
16000 |
2 |
|
NOTE: All sensitivity values are expressed in dB on an arbitrary scale. |
Figure 16b: Electrical interface sensitivity/frequency masks. The frequency response of the EVS codec operating as specified in TS 26.132 (super-wideband 24,4kbit/s, using the specified P.501 speech test signal), is plotted for reference, normalized to 0dB at 1kHz.
A UE operating in super-wideband mode shall pass the super-wideband requirements (i.e. when measured according to in 1/3rd octaves) as specified in Table 30a2, and shall also pass the wideband sensitivity/frequency characteristics requirements in the wideband range using the wideband measurement (i.e. measured in 1/12th octaves) as specified in Table 14a2.
Compliance shall be checked by the relevant test described in TS 26.132.