9.1.32 RESOURCE STATUS INDICATION

25.4333GPPRelease 17TSUTRAN Iub interface Node B Application Part (NBAP) signalling

IE/Group Name

Presence

Range

IE Type and Reference

Semantics Description

Criticality

Assigned Criticality

Message Discriminator

M

9.2.1.45

Message Type

M

9.2.1.46

YES

ignore

Transaction ID

M

9.2.1.62

CHOICE Indication Type

M

YES

ignore

>No Failure

>>Local Cell Information

1..<max LocalCellinNode B>

EACH

ignore

>>>Local Cell ID

M

9.2.1.38

>>>Add/Delete Indicator

M

9.2.1.1

>>>DL Or Global Capacity Credit

C-add

9.2.1.20B

>>>UL Capacity Credit

O

9.2.1.65A

>>>Common Channels Capacity Consumption Law

C-add

9.2.1.9A

>>>Dedicated Channels Capacity Consumption Law

C-add

9.2.1.20A

>>>Maximum DL Power Capability

C-add

9.2.1.39

>>>Minimum Spreading Factor

C-add

9.2.1.47

>>>Minimum DL Power Capability

C-add

9.2.1.46A

>>>Local Cell Group ID

O

9.2.1.37A

>>>Reference Clock Availability

O

9.2.3.14A

TDD only

YES

ignore

>>>Power Local Cell Group ID

O

9.2.1.49B

YES

ignore

>>>HSDPA Capability

O

9.2.1.31Ga

YES

ignore

>>>E-DCH Capability

O

9.2.1.70

YES

ignore

>>>E-DCH TTI2ms Capability

C-EDCHCapability

9.2.2.13V

FDD only

YES

ignore

>>>E-DCH SF Capability

C-EDCHCapability

9.2.2.13W

FDD only

YES

ignore

>>>E-DCH HARQ Combining Capability

C-EDCHCapability

9.2.2.13X

FDD only

YES

ignore

>>>E-DCH Capacity Consumption Law

O

9.2.2.13Ja

FDD only

YES

ignore

>>>F-DPCH Capability

O

9.2.2.16a

FDD only

YES

ignore

>>>E-DCH TDD Capacity Consumption Law

O

9.2.3.60

TDD only

YES

ignore

>>>Continuous Packet Connectivity DTX-DRX Capability

O

9.2.2.64

FDD only

YES

ignore

>>>Max UE DTX Cycle

C-DTX-DRXCapability

9.2.2.95

FDD only

YES

ignore

>>>Continuous Packet Connectivity HS-SCCH less Capability

O

9.2.2.65

FDD only

YES

ignore

>>>MIMO Capability

O

9.2.1.118

FDD and 1.28Mcps TDD only

YES

ignore

>>>SixtyfourQAM DL Capability

O

9.2.1.110

FDD and 1.28Mcps TDD only

YES

ignore

>>>MBMS Capability

O

9.2.1.86

YES

ignore

>>>Enhanced FACH Capability

O

9.2.1.114

FDD and 1.28Mcps TDD only

YES

ignore

>>>Enhanced PCH Capability

C-EnhancedFACHCapability

9.2.1.115

FDD and 1.28Mcps TDD only

YES

ignore

>>>SixteenQAM UL Capability

O

9.2.2.88

FDD only

YES

ignore

>>>HS-DSCH MAC-d PDU Size Capability

O

9.2.1.31IC

YES

ignore

>>>MBSFN Only Mode Capability

O

9.2.3.71

1.28Mcps TDD only

YES

ignore

>>>F-DPCH Slot Format Capability

O

9.2.2.94

FDD only

YES

ignore

>>>E-DCH MAC-d PDU Size Capability

O

9.2.1.74A

YES

ignore

>>>Common E-DCH Capability

O

9.2.2.101

FDD only

YES

Ignore

>>>E-AI Capability

C-CommonEDCHCapability

9.2.2.102

FDD only

YES

Ignore

>>>Enhanced UE DRX Capability

O

9.2.1.116

FDD only

YES

ignore

>>>Enhanced UE DRX Capability LCR

O

Enhanced UE DRX Capability

9.2.1.116

1.28Mcps TDD only

YES

ignore

>>>E-DPCCH Power Boosting Capability

O

9.2.2.109

YES

ignore

>>>SixtyfourQAM DL and MIMO Combined Capability

O

9.2.1.121

FDD and 1.28Mcps TDD only

YES

ignore

>>>Multi Cell Capability Info

O

9.2.2.113

FDD only

YES

ignore

>>>Semi-Persistent scheduling Capability LCR

O

9.2.3.91

1.28Mcps TDD only

YES

ignore

>>>Continuous Packet Connectivity DRX Capability LCR

O

9.2.3.92

1.28Mcps TDD only

YES

ignore

>>>Common E-DCH HS-DPCCH Capability

C-CommonEDCHCapability

9.2.2.116

FDD only

YES

Ignore

>>>MIMO Power Offset For S-CPICH Capability

O

9.2.2.118

FDD only

YES

ignore

>>>TX Diversity on DL Control Channels by MIMO UE Capability

O

9.2.2.121

FDD only

YES

ignore

>>>Single Stream MIMO Capability

O

9.2.2.122

FDD only

YES

Ignore

>>>Dual Band Capability Info

O

9.2.2.125

FDD only

YES

ignore

>>>Cell Portion Capability LCR

O

9.2.3.106

1.28Mcps TDD only

YES

ignore

>>>Cell Capability Container

O

9.2.2.129

FDD only

YES

ignore

>>>TS0 Capability LCR

O

9.2.3.109

1.28Mcps TDD only

YES

ignore

>>>Precoding Weight Set Restriction

O

9.2.2.143

FDD only

YES

ignore

>>>Cell Capability Container TDD LCR

O

9.2.3.115

1.28Mcps TDD only

YES

ignore

>>>MU-MIMO Capability Container

O

9.2.3.119

1.28Mcps TDD only

YES

ignore

>>>Adaptive Special Burst Power Capability LCR

O

9.2.3.122

1.28Mcps TDD only

YES

ignore

>>Local Cell Group Information

0..<maxLocalCellinNodeB>

EACH

ignore

>>>Local Cell Group ID

M

9.2.1.37A

>>>DL Or Global Capacity Credit

M

9.2.1.20B

>>>UL Capacity Credit

O

9.2.1.65A

>>>Common Channels Capacity Consumption Law

M

9.2.1.9A

>>>Dedicated Channels Capacity Consumption Law

M

9.2.1.20A

>>>E-DCH Capacity Consumption Law

O

9.2.2.13Ja

FDD only

YES

ignore

>>>E-DCH TDD Capacity Consumption Law

O

9.2.3.60

TDD only

YES

ignore

>>Power Local Cell Group Information

0..<maxLocalCellinNodeB>

EACH

ignore

>>>Power Local Cell Group ID

M

9.2.1.49B

>>>Maximum DL Power Capability

M

9.2.1.39

>Service Impacting

>>Local Cell Information

0..<maxLocalCellinNodeB>

EACH

ignore

>>>Local Cell ID

M

9.2.1.38

>>>DL Or Global Capacity Credit

O

9.2.1.20B

>>>UL Capacity Credit

O

9.2.1.65A

>>>Common Channels Capacity Consumption Law

O

9.2.1.9A

>>>Dedicated Channels Capacity Consumption Law

O

9.2.1.20A

>>>Maximum DL Power Capability

O

9.2.1.39

>>>Minimum Spreading Factor

O

9.2.1.47

>>>Minimum DL Power Capability

O

9.2.1.46A

>>>Reference Clock Availability

O

9.2.3.14A

TDD only

YES

ignore

>>>HSDPA Capability

O

9.2.1.31Ga

YES

ignore

>>>E-DCH Capability

O

9.2.1.70

YES

ignore

>>>E-DCH TTI2ms Capability

C-EDCHCapability

9.2.2.13V

FDD only

YES

ignore

>>>E-DCH SF Capability

C-EDCHCapability

9.2.2.13W

FDD only

YES

ignore

>>>E-DCH HARQ Combining Capability

C-EDCHCapability

9.2.2.13X

FDD only

YES

ignore

>>>E-DCH Capacity Consumption Law

O

9.2.2.13Ja

FDD only

YES

ignore

>>>F-DPCH Capability

O

9.2.2.16a

YES

ignore

>>>E-DCH TDD Capacity Consumption Law

O

9.2.3.60

TDD only

YES

ignore

>>>Continuous Packet Connectivity DTX-DRX Capability

O

9.2.2.64

FDD only

YES

ignore

>>>Max UE DTX Cycle

C-DTX-DRXCapability

9.2.2.95

FDD only

YES

ignore

>>>Continuous Packet Connectivity HS-SCCH less Capability

O

9.2.2.65

FDD only

YES

ignore

>>>MIMO Capability

O

9.2.1.118

FDD and 1.28Mcps TDD only

YES

ignore

>>>SixtyfourQAM DL Capability

O

9.2.1.110

FDD and 1.28Mcps TDD only

YES

ignore

>>>MBMS Capability

O

9.2.1.86

YES

ignore

>>>Enhanced FACH Capability

O

9.2.1.114

FDD only and 1.28Mcps TDD

YES

ignore

>>>Enhanced PCH Capability

C-EnhancedFACHCapability

9.2.1.115

FDD only and 1.28Mcps TDD

YES

ignore

>>>SixteenQAM UL Capability

O

9.2.2.88

FDD only

YES

ignore

>>>HS-DSCH MAC-d PDU Size Capability

O

9.2.1.31IC

YES

ignore

>>>MBSFN Only Mode Capability

O

9.2.3.71

1.28Mcps TDD only

YES

ignore

>>>F-DPCH Slot Format Capability

O

9.2.2.94

FDD only

YES

ignore

>>>E-DCH MAC-d PDU Size Capability

O

9.2.1.74A

YES

ignore

>>>Common E-DCH Capability

O

9.2.2.101

FDD only

YES

Ignore

>>>E-AI Capability

C-CommonEDCHCapability

9.2.2.102

FDD only

YES

Ignore

>>>Enhanced UE DRX Capability

O

9.2.1.116

FDD only

YES

ignore

>>>Enhanced UE DRX Capability LCR

O

Enhanced UE DRX Capability

9.2.1.116

1.28Mcps TDD only

YES

ignore

>>>E-DPCCH Power Boosting Capability

O

9.2.2.109

YES

ignore

>>>SixtyfourQAM DL and MIMO Combined Capability

O

9.2.1.121

FDD and 1.28Mcps TDD only

YES

ignore

>>>Multi Cell Capability Info

O

9.2.2.113

FDD only

YES

ignore

>>>Semi-Persistent scheduling Capability LCR

O

9.2.3.91

1.28Mcps TDD only

YES

ignore

>>>Continuous Packet Connectivity DRX Capability LCR

O

9.2.3.92

1.28Mcps TDD only

YES

ignore

>>>Common E-DCH HS-DPCCH Capability

C-CommonEDCHCapability

9.2.2.116

FDD only

YES

Ignore

>>>MIMO Power Offset For S-CPICH Capability

O

9.2.2.118

FDD only

YES

ignore

>>>TX Diversity on DL Control Channels by MIMO UE Capability

O

9.2.2.121

FDD only

YES

ignore

>>>Single Stream MIMO Capability

O

9.2.2.122

FDD only

YES

Ignore

>>>Dual Band Capability Info

O

9.2.2.125

FDD only

YES

ignore

>>>Cell Portion Capability LCR

O

9.2.3.106

1.28Mcps TDD only

YES

ignore

>>>Cell Capability Container

O

9.2.2.129

FDD only

YES

ignore

>>>TS0 Capability LCR

O

9.2.3.109

1.28Mcps TDD only

YES

ignore

>>>Precoding Weight Set Restriction

O

9.2.2.143

FDD only

YES

ignore

>>>Cell Capability Container TDD LCR

O

9.2.3.115

1.28Mcps TDD only

YES

ignore

>>>MU-MIMO Capability Container

O

9.2.3.119

1.28Mcps TDD only

YES

ignore

>>>Adaptive Special Burst Power Capability LCR

O

9.2.3.122

1.28Mcps TDD only

YES

ignore

>>Local Cell Group Information

0..<maxLocalCellinNodeB>

EACH

ignore

>>>Local Cell Group ID

M

9.2.1.37A

>>>DL Or Global Capacity Credit

O

9.2.1.20B

>>>UL Capacity Credit

O

9.2.1.65A

>>>Common Channels Capacity Consumption Law

O

9.2.1.9A

>>>Dedicated Channels Capacity Consumption Law

O

9.2.1.20A

>>>E-DCH Capacity Consumption Law

O

9.2.2.13Ja

FDD only

YES

ignore

>>>E-DCH TDD Capacity Consumption Law

O

9.2.3.60

TDD only

YES

ignore

>>Communication Control Port Information

0..<maxCCPinNodeB>

EACH

ignore

>>>Communication Control Port ID

M

9.2.1.15

>>>Resource Operational State

M

9.2.1.52

>>>Availability Status

M

9.2.1.2

>>Cell Information

0..<maxCellinNodeB>

EACH

ignore

>>>C-ID

M

9.2.1.9

>>>Resource Operational State

O

9.2.1.52

>>>Availability Status

O

9.2.1.2

>>>Primary SCH Information

O

Common Physical Channel Status Information 9.2.1.13A

FDD only

YES

ignore

>>>Secondary SCH Information

O

Common Physical Channel Status Information 9.2.1.13A

FDD only

YES

ignore

>>>Primary CPICH Information

O

Common Physical Channel Status Information 9.2.1.13A

FDD only

YES

ignore

>>>Secondary CPICH Information

0..<maxSCPICHCell>

FDD only

EACH

ignore

>>>>Secondary CPICH Individual Information

M

Common Physical Channel Status Information 9.2.1.13A

>>>Primary CCPCH Information

O

Common Physical Channel Status Information 9.2.1.13A

YES

ignore

>>>BCH Information

O

Common Transport Channel Status Information 9.2.1.14B

YES

ignore

>>>Secondary CCPCH Information

0..<maxSCCPCHCell>

See note 1 below

EACH

ignore

>>>>Secondary CCPCH Individual Information

M

Common Physical Channel Status Information 9.2.1.13A

>>>PCH Information

O

Common Transport Channel Status Information 9.2.1.14B

YES

ignore

>>>PICH Information

O

Common Physical Channel Status Information 9.2.1.13A

YES

ignore

>>>FACH Information

0..<maxFACHCell>

EACH

ignore

>>>>FACH Individual Information

M

Common Transport Channel Status Information 9.2.1.14B

>>>PRACH Information

0..<maxPRACHCell>

EACH

ignore

>>>>PRACH Individual Information

M

Common Physical Channel Status Information 9.2.1.13A

>>>RACH Information

0..<maxPRACHCell>

EACH

ignore

>>>>RACH Individual Information

M

Common Transport Channel Status Information 9.2.1.14B

>>>AICH Information

0..<maxPRACHCell>

FDD only

EACH

ignore

>>>>AICH Individual Information

M

Common Physical Channel Status Information 9.2.1.13A

>>>Not Used 1

O

NULL

This item shall not be used. Ignore if received.

>>>Not Used 2

O

NULL

This item shall not be used. Ignore if received.

>>>Not Used 3

O

NULL

This item shall not be used. Ignore if received.

>>>Not Used 4

O

NULL

This item shall not be used. Ignore if received.

>>>SCH Information

O

Common Physical Channel Status Information 9.2.1.13A

Applicable to 3.84Mcps TDD only

YES

ignore

>>>FPACH Information

0..<maxFPACHCell>

Applicable to 1.28Mcps TDD only

EACH

ignore

>>>>FPACH Individual Information

M

Common Physical Channel Status Information 9.2.1.13A

>>>DwPCH Information

O

Common Physical Channel Status Information 9.2.1.13A

Applicable to 1.28Mcps TDD only

YES

ignore

>>>HS-DSCH Resources Information

0.. <maxFrequencyinCell>

See note 2 below

EACH

ignore

>>>>Resource Operational State

M

9.2.1.52

>>>>Availability Status

M

9.2.1.2

>>>>UARFCN

O

9.2.1.65

Corresponds to Nt (TS 25.105 [15]).

Applicable to 1.28Mcps TDD when using multiple frequencies.

YES

ignore

>>>MICH Information

O

Common Physical Channel Status Information 9.2.1.13A

YES

ignore

>>>E-DCH Resources Information

0..<maxFrequencyinCell>

See note 2 below

EACH

ignore

>>>>Resource Operational State

M

9.2.1.52

>>>>Availability Status

M

9.2.1.2

>>>>UARFCN

O

9.2.1.65

Corresponds to Nt (TS 25.105 [15]).

Applicable to 1.28Mcps TDD when using multiple frequencies.

YES

ignore

>>>PLCCH Information

0..<maxPLCCHCell>

Applicable to 1.28Mcps TDD only

EACH

ignore

>>>>PLCCH Individual Information

M

Common Physical Channel Status Information 9.2.1.13A

>>>Primary CCPCH Information 7.68Mcps

O

Common Physical Channel Status Information 7.68Mcps 9.2.3.36

YES

ignore

>>>Secondary CCPCH Information 7.68Mcps

0..<maxSCCPCHCell768>

EACH

ignore

>>>>Secondary CCPCH Individual Information 7.68Mcps

M

Common Physical Channel Status Information 7.68Mcps 9.2.3.36

>>>PICH Information 7.68Mcps

O

Common Physical Channel Status Information 7.68Mcps 9.2.3.36

YES

ignore

>>>PRACH Information 7.68Mcps

0..<maxPRACHCell>

EACH

ignore

>>>>PRACH Individual Information 7.68Mcps

M

Common Physical Channel Status Information 7.68Mcps 9.2.3.36

>>>SCH Information 7.68Mcps

O

Common Physical Channel Status Information 7.68Mcps 9.2.3.36

Applicable to 7.68Mcps TDD only

YES

ignore

>>>MICH Information 7.68Mcps

O

Common Physical Channel Status Information 7.68Mcps 9.2.3.36

YES

ignore

>>>E-RUCCH Information

0..<maxE-RUCCHCell>

Applicable to 3.84Mcps TDD only

EACH

ignore

>>>>E-RUCCH Individual Information

M

Common Physical Channel Status Information 9.2.1.13A

>>>E-RUCCH Information 7.68Mcps

0..<maxE-RUCCHCell>

Applicable to 7.68Mcps TDD only

EACH

ignore

>>>>E-RUCCH Individual Information 7.68Mcps

M

Common Physical Channel Status Information 7.68Mcps 9.2.3.36

>>>UARFCN Information LCR

0..<maxFrequencyinCell>

Applicable to 1.28Mcps TDD when using multiple frequencies.

EACH

ignore

>>>>UARFCN

M

9.2.1.65

Corresponds to Nt (TS 25.105 [15]).

>>>>Resource Operational State

M

9.2.1.52

>>>>Availability Status

M

9.2.1.2

>>>>Cause

O

9.2.1.6

>>>UpPCH Information LCR

0..<maxFrequencyinCell>

Applicable to 1.28Mcps TDD only.

EACH

ignore

>>>>UARFCN

O

9.2.1.65

Mandatory for 1.28Mcps TDD when using multiple frequencies. Corresponds to Nt (TS 25.105 [15]).

>>>>UpPCH Position LCR

M

9.2.3.4Q

>>>>Resource Operational State

M

9.2.1.52

>>>>Availability Status

M

9.2.1.2

>>Power Local Cell Group Information

0..<maxLocalCellinNodeB>

EACH

ignore

>>>Power Local Cell Group ID

M

9.2.1.49B

>>>Maximum DL Power Capability

M

9.2.1.39

Cause

O

9.2.1.6

YES

ignore

NOTE 1: This information element is a simplified representation of the ASN.1. [TDD – Repetitions 1 to 8 and repetitions 9 to maxSCCPCHCell are represented by separate ASN.1 structures.] Furthermore, maxSCCPCHCell has different values in the ASN.1 for FDD and for each of the two TDD options.

NOTE 2: For 1.28Mcps TDD when using multiple frequencies, this information element for Repetition 1 and repetition 2 through maxFrequencyinCell are represented by respective ASN.1 structures with different criticalities.

Condition

Explanation

add

The IE shall be present if the Add/Delete Indicator IE is set to "Add".

EDCHCapability

The IE shall be present if the E-DCH Capability IE is set to "E-DCH Capable".

EnhancedFACHCapability

The IE shall be present if the Enhanced FACH Capability IE is set to "Enhanced FACH Capable".

DTX-DRXCapability

The IE shall be present if the Continuous Packet Connectivity DTX-DRX Capability IE is present and set to " Continuous Packet Connectivity DTX-DRX Capable".

CommonEDCHCapability

The IE shall be present if the Common E-DCH Capability IE is set to "Common E-DCH Capable".

Range Bound

Explanation

maxLocalCellinNodeB

Maximum number of Local Cells that can exist in the Node B

maxCellinNodeB

Maximum number of C-IDs that can be configured in the Node B

maxSCPICHCell

Maximum number of Secondary CPICHs that can be defined in a Cell.

maxSCCPCHCell

Maximum number of Secondary CCPCHs that can be defined in a Cell.

maxFACHCell

Maximum number of FACHs that can be defined in a Cell

maxPRACHCell

Maximum number of PRACHs and AICHs that can be defined in a Cell

maxCCPinNodeB

Maximum number of Communication Control Ports that can exist in the Node B

maxFPACHCell

Maximum number of FPACHs that can be defined in a Cell

maxPLCCHCell

Maximum number of PLCCHs that can be defined in a Cell

maxE-RUCCHCell

Maximum number of E-RUCCHs that can be defined in a Cell

maxFrequencyinCell