9.1.27 CELL RECONFIGURATION REQUEST

25.4333GPPRelease 17TSUTRAN Iub interface Node B Application Part (NBAP) signalling

9.1.27.1 FDD Message

IE/Group Name

Presence

Range

IE Type and Reference

Semantics Description

Criticality

Assigned Criticality

Message Discriminator

M

9.2.1.45

Message Type

M

9.2.1.46

YES

reject

Transaction ID

M

9.2.1.62

C-ID

M

9.2.1.9

YES

reject

Configuration Generation ID

M

9.2.1.16

YES

reject

Maximum Transmission Power

O

9.2.1.40

YES

reject

Synchronisation Configuration

0..1

YES

reject

>N_INSYNC_IND

M

9.2.1.47A

>N_OUTSYNC_IND

M

9.2.1.47B

>T_RLFAILURE

M

9.2.1.56A

Primary SCH Information

0..1

YES

reject

>Common Physical Channel ID

M

9.2.1.13

>Primary SCH Power

M

DL Power

9.2.1.21

Secondary SCH Information

0..1

YES

reject

>Common Physical Channel ID

M

9.2.1.13

>Secondary SCH Power

M

DL Power

9.2.1.21

Primary CPICH Information

0..1

YES

reject

>Common Physical Channel ID

M

9.2.1.13

>Primary CPICH Power

M

9.2.2.33

Secondary CPICH Information

0..<maxSCPICHCell>

EACH

reject

>Common Physical Channel ID

M

9.2.1.13

>Secondary CPICH Power

M

DL Power

9.2.1.21

Primary CCPCH Information

0..1

YES

reject

>BCH Information

1

>>Common Transport Channel ID

M

9.2.1.14

>>BCH Power

M

DL Power

9.2.1.21

IPDL Parameter Information

0..1

YES

reject

>IPDL FDD Parameters

O

9.2.2.18C

>IPDL Indicator

M

9.2.1.36F

Cell Portion Information

0..<maxNrOfCellPortionsPerCell>

EACH

reject

>Cell Portion ID

M

9.2.2.1Ca

>Maximum Transmission Power for Cell Portion

M

Maximum Transmission Power

9.2.1.40

MIMO Pilot Configuration

O

9.2.2.73

YES

reject

MIMO Pilot Configuration Extension

O

9.2.2.120

YES

reject

Dormant Mode Indicator

O

9.2.1.124

YES

reject

MIMO with four transmit antennas Pilot Configuration

O

9.2.2.165

YES

reject

Range Bound

Explanation

maxSCPICHCell

Maximum number of Secondary CPICH that can be defined in a Cell.

maxNrOfCellPortionsPerCell

Maximum number of Cell Portions in a cell

9.1.27.2 TDD Message

IE/Group Name

Presence

Range

IE Type and Reference

Semantics Description

Criticality

Assigned Criticality

Message Discriminator

M

9.2.1.45

Message Type

M

9.2.1.46

YES

reject

Transaction ID

M

9.2.1.62

C-ID

M

9.2.1.9

YES

reject

Configuration Generation ID

M

9.2.1.16

YES

reject

Synchronisation Configuration

0..1

YES

reject

>N_INSYNC_IND

M

9.2.1.47A

>N_OUTSYNC_IND

M

9.2.1.47B

>T_RLFAILURE

M

9.2.1.56A

Timing Advance Applied

O

9.2.3.22A

YES

reject

SCH Information

0..1

Applicable to 3.84Mcps TDD only

YES

reject

>Common Physical Channel ID

M

9.2.1.13

>SCH Power

M

DL Power

9.2.1.21

PCCPCH Information

0..1

Not applicable to 7.68Mcps TDD only.

For 1.28 Mcps TDD, if the cell is operating in MBSFN only mode, PCCPCH is deployed on the MBSFN Special Time Slot (TS 25.221 [19]).

YES

reject

>Common Physical Channel ID

M

9.2.1.13

>PCCPCH Power

M

9.2.3.9

Maximum Transmission Power

O

9.2.1.40

YES

reject

DPCH Constant Value

O

Constant Value 9.2.3.4A

This IE shall be ignored by the Node B.

YES

reject

PUSCH Constant Value

O

Constant Value 9.2.3.4A

This IE shall be ignored by the Node B.

YES

reject

PRACH Constant Value

O

Constant Value 9.2.3.4A

This IE shall be ignored by the Node B.

YES

reject

Time Slot Configuration

0..15

Mandatory for 3.84Mcps TDD and 7.68Mcps TDD. Not Applicable to 1.28Mcps TDD.

GLOBAL

reject

>Time Slot

M

9.2.3.23

>Time Slot Status

M

9.2.3.25

>Time Slot Direction

M

9.2.3.24

>MBSFN Cell Parameter ID

O

Cell Parameter ID

9.2.3.4

YES

reject

Time Slot Configuration LCR

0..7

Mandatory for 1.28Mcps TDD. Not Applicable to 3.84Mcps TDD or 7.68Mcps TDD.

If multiple frequencies exist within the cell indicated by C-ID, this IE indicates the Time Slot reconfiguration of Primary Frequency.

GLOBAL

reject

>Time Slot LCR

M

9.2.3.24A

>Time Slot Status

M

9.2.3.25

>Time Slot Direction

M

9.2.3.24

DwPCH Information

0..1

Applicable to 1.28Mcps TDD only.

YES

reject

>Common Physical Channel ID

M

9.2.1.13

>DwPCH Power

M

9.2.3.5B

IPDL Parameter Information

0..1

Applicable to 3.84Mcps TDD and 7.68Mcps TDD only

YES

reject

>IPDL TDD Parameters

O

9.2.3.5D

>IPDL Indicator

M

9.2.1.36F

IPDL Parameter Information LCR

0..1

Applicable to 1.28Mcps TDD only

YES

reject

>IPDL TDD Parameters LCR

O

9.2.3.5H

>IPDL Indicator

M

9.2.1.36F

SCH Information 7.68Mcps

0..1

Applicable to 7.68Mcps TDD only

YES

reject

>Common Physical Channel ID 7.68Mcps

M

9.2.3.33

>SCH Power

M

DL Power

9.2.1.21

PCCPCH Information 7.68Mcps

0..1

Applicable to 7.68Mcps TDD only

YES

reject

>Common Physical Channel ID 7.68Mcps

M

9.2.3.33

>PCCPCH Power

M

9.2.3.9

CHOICE UARFCN Adjustment

O

Applicable to 1.28Mcps TDD when using multiple frequencies

YES

reject

>Add

>>UARFCN Information To Add LCR

1

>>>UARFCN

M

9.2.1.65

Corresponds to Nt (TS 25.105 [15]).

This IE indicates the frequency of a Secondary Frequency to add.

>>>Time Slot Configuration LCR

1..7

This IE indicates the Time Slot configuration of a Secondary Frequency to add.

>>>>Time Slot LCR

M

9.2.3.24A

>>>>Time Slot Status

M

9.2.3.25

>>>>Time Slot Direction

M

9.2.3.24

>Modify

>>UARFCN Information To Modify LCR

1.. <maxFrequencyinCell-1>

there could be several secondary frequencies

>>>UARFCN

M

9.2.1.65

Corresponds to Nt (TS 25.105 [15]).

This IE indicates the frequency of a Secondary Frequency to modify.

>>>Time Slot Configuration LCR

1..7

This IE indicates the Time Slot reconfiguration of a Secondary Frequency to modify.

>>>>Time Slot LCR

M

9.2.3.24A

>>>>Time Slot Status

M

9.2.3.25

>>>>Time Slot Direction

M

9.2.3.24

>Delete

>>UARFCN Information To Delete LCR

1

>>>UARFCN

M

9.2.1.65

Corresponds to Nt (TS 25.105 [15]).

This IE indicates the frequency of Secondary Frequency to delete.

Dormant Mode Indicator

O

9.2.1.124

YES

reject

Range Bound

Explanation

maxFrequencyinCell

Maximum number of Frequencies that can be defined in a Cell