8.3.25 UE Measurement Failure [TDD]
25.4233GPPRelease 17TSUTRAN Iur interface Radio Network Subsystem Application Part (RNSAP) signalling
8.3.25.1 General
This procedure is used by the SRNC to notify the DRNC that a measurement previously requested by the UE Measurement Initiation procedure can no longer be reported.
This procedure shall use the signalling bearer connection for the relevant UE Context.
The SRNC may initiate the UE Measurement Failure procedure at any time after establishing a Radio Link.
8.3.25.2 Successful Operation
Figure 26J: UE Measurement Failure procedure, Successful Operation
This procedure is initiated with a UE MEASUREMENT FAILURE INDICATION message, sent from the SRNC to the DRNC, to inform the DRNC that a previously requested UE measurement can no longer be reported. The SRNC has locally terminated the forwarding of the indicated measurement. The SRNC shall include in the UE MEASUREMENT FAILURE INDICATION message the reason for the failure in the Cause IE.
Typical cause values are:
Miscellaneous Causes:
– Control Processing Overload;
– HW Failure;
– O&M Intervention.
8.3.25.3 Abnormal Conditions
–