8.3.24 UE Measurement Termination [TDD]
25.4233GPPRelease 17TSUTRAN Iur interface Radio Network Subsystem Application Part (RNSAP) signalling
8.3.24.1 General
This procedure is used by the DRNC to terminate a measurement previously requested by the UE Measurement Initiation procedure.
This procedure shall use the signalling bearer connection for the relevant UE Context.
The UE Measurement Termination procedure shall not be initiated if a Prepared Reconfiguration exists, as defined in subclause 3.1.
8.3.24.2 Successful Operation
Figure 26I: UE Measurement Termination procedure, Successful Operation
This procedure is initiated with a UE MEASUREMENT TERMINATION REQUEST message, sent from the DRNC to the SRNC.
Upon receipt, the SRNC shall terminate forwarding of UE measurements corresponding to the received Measurement ID IE.
8.3.24.3 Abnormal Conditions
–